Neurio Technology ULC N1LD Communication Module User Manual
Energy Aware Technology Inc Communication Module
Contents
- 1. User Manual
- 2. Installation Guide
- 3. Installation Guide - User Manual
User Manual
home energy monitor by Neurio Technology P RELI M I N A RY D O N OT D I ST RI B UT E W2 Installation Guide Welcome This booklet will guide you or your electrican through the installation process of Neurio. We will focus on a 2-phase system, the most common power system in North America. If you have a one-phase or 3-phase or solar system, please visit support.neur.io for instructions Items to prepare before installation • Smartphone • Flashlight • Thick insulated rubber gloves • Screwdrivers • Pliers • Two empty breakers (or one dual pole breaker)* To watch a video of the installation process, visit support.neur.io CAUTION: It is highly recommended that this product be installed by an electrician or other qualified professional. Please read and review the safety warning provided at the end of this book * The voltage cables on the Neurio Sensor need to be installed on two empty breakers (one for each phase) or one empty dual (double) pole breaker. However, some regional codes allow you to piggyback wires on existing breakers by using the supplied wiretaps and attaching the voltage wires from Neurio to the existing cables before they go into a breaker. See Step 4 for diagrams. Please consult your local electrical code for approved methods. What's included Neurio W2 Sensor Current Transformers (x2) Voltage Cable Antenna and extension cable Mounting Plate Antenna Mounts (x2) Marrette (x1) Screws (x2) Jumper Wires (x2) Wiretaps (x2) Cable Ties (x2) Neurio Sticker Overview of Install Step 1 Step 6 Turn off the main breaker Connect the antenna Step 2 Step 7 Remove the panel cover Check your work Step 3 Step 8 Mount the sensor Replace the panel cover Step 4 Step 9 Connect the voltage cable Connect Neurio to WiFi Step 5 Connect the CTs If you get stuck at any point, visit support.neur.io for walkthrough videos and helpful tips. Step 1: Turn off main breaker Simply flip the switch to turn off the Main Breaker. ON OFF Note: If you have more than 1 electrical panel, make sure Neurio is installed in the main one (the one that draws power directly from your utility). Step 2: Remove panel cover Remove the screws on the corners of the panel and remove the cover. After you do this, you should see the wires going into each breaker and main lines from the utility.. ON Note: If your panel has a secondary cover that hides the main utility line, please remove that as well. OFF Step 3: Mount the W2 Sensor Find a suitable place in your panel where Neurio can fit. Then, using the supplied self-drilling screws, secure the mounting plate to your metal panel. Now clip your Neurio into place. Note: Drilling pilot holes may make it easier to mount Neurio into metal panel ON OFF CAUTION: Be sure to account for the length of the CTs and the 2-foot voltage cable, and ensure that there is enough room on the sides of Neurio for the wires and antenna to connect to.. Step 4: Connect the Voltage Cable a) Connect the voltage cable to Neurio by inserting the connector b) Connect the black and red wires to the empty 15 or 20 amp breakers. Connect the white wire to the neutral bus bar usually located next to the breaker. ON OFF Note: To remove wire from wiretap, simple pull on the wire and twist Alternate wiring with wiretap If an empty breaker isn’t available, you can use the provided wiretaps to connect to an existing breaker. To do this, remove the existing wire from a 15 or 20 amp breaker and replace it with the jumper wire provided in the contents of the box. Then use the wiretap to connect the jumper wire, the wire from Neurio, and the original wire you removed from the breaker. It might take a little force to ensure the wires are secured into the wiretap all the way. Note: The blue wire is not used for 2 phase installs. Twist the marrette onto the blue wire and tuck it into the panel, out of the way Step 5: Connect the CTs a) For Universal CTs, just pinch the handle to open the jaws CAUTION: Be sure to take care to not touch the exposed main line connections to the main breaker b) Loop the CT around each of the main power lines. Pay close attention to the label. The direction it faces is very important. ON OFF c) Insert the CT connectors to the ports labeled [1] and [2]. Step 6: Hook up the antenna a) Attach the extension cable to the Neurio Sensor b) Locate a metal circular knockout in your panel and remove the metal to expose the hole. Gently tapping with a hammer may be needed. c) Thread the extension cable through the antenna mount and screw on the antenna. d) Insert the antenna through the open knockout and click the antenna mount in to place ON OFF Step 7: Review your work a) Antenna with extension cable b) Neurio W2 Sensor c) Voltage Cable i) Blue and Red wire to 2 breakers ii)Black wire to Neutral to bus bar d) CT Connector i) Connector around mains ii) Make sure the label is facing .. Note: The 2 cable ties are provided to help tidy up your wiring ON OFF Step 8: Put on panel cover You're almost done. Replace the cover on your panel. Make sure to place the supplied Neurio breaker sticker next to the breaker that Neurio's black wire. ON OFF When powered on, Neurio will play the following tones to indicate its status in sequential order: TO N E I N D I CAT I O N DESCRIPTION Voltage check One beep for each voltage wire that is connected. For a 2-phase installation there should be two beeps to indicate that the black and red wires are connected. Neurio’s WiFi network started Neurio has started hosting its own WiFi network. You can join this network to configure Neurio and connect it to your own WiFi network. Voltage warning (conditional) Indicates that two wires are connected to the same phase. For North American apartments, this means that one of Neurio’s wires should be moved to a different breaker. This tone can be ignored for all other 2-phase installations. Short beeps Short chime Long beep Long chime Falling tone Neurio joined network successfully Neurio failed to join network Neurio successfully joined your WiFi network. Neurio was unable to join your WiFi network. Neurio will now start hosting its own WiFi network again to allow you to re-connect to Neurio and re-enter the WiFi credentials. If Neurio is connected to the WiFi network, you should also hear a long chime one minute after the short chime. Step 9: Connect Neurio to Wifi Now that the Neurio Sensor has been installed, please follow the instructions in the Welcome Guide to connect Neurio to the Wifi Network. WHAT DOES THIS WARRANTY COVER? Neurio Technology Inc., a corporation registered under the laws of British Columbia, (“we”, “us”, or “our”) warrants this Energy Monitor hardware (“Neurio”) to be free from defects in materials and workmanship when used in accordance with our published guidelines (the “Warranty”) for a period of ONE (1) YEAR from the date the Neurio is delivered to you (the “Warranty Period”). WARRANTY LIMITATIONS THIS WARRANTY SHALL NOT EXTEND BEYOND THE WARRANTY PERIOD. TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY AND THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE, AND ARE IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL, WRITTEN, STATUTORY, EXPRESS OR IMPLIED. WE DISCLAIM ALL STATUTORY AND IMPLIED CONDITIONS, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WARRANTIES ARISING BY CUSTOM, USAGE OR TRADE, AND WARRANTIES AGAINST HIDDEN OR LATENT DEFECTS, TO THE EXTENT PERMITTED BY LAW. IN SO FAR AS SUCH WARRANTIES CANNOT BE DISCLAIMED, WE LIMIT THE DURATION AND REMEDIES OF SUCH WARRANTIES TO THE WARRANTY PERIOD, AND, AT OUR OPTION, TO THE REPAIR OR REPLACEMENT SERVICES DESCRIBED BELOW. WHAT WE WILL DO IF THE WARRANTY IS BREACHED If, during the Warranty Period, you submit a valid claim to us, we will, at our exclusive option and without charge, (i) repair the Neurio using new or previously used parts that are equivalent to new in performance and reliability, and return the repaired Neurio to you, or (ii) send you a replacement Neurio. Any repairs or replacements are warranted for the remainder of the initial Warranty Period. HOW TO OBTAIN WARRANTY SERVICE To obtain Warranty service within the Warranty Period, you must return the Neurio, freight paid, with a copy of the sales receipt or other proof of purchase that shows the date of sale and/or delivery date, to: Neurio Technology Inc. , 515-88 E Pender St, Vancouver, BC, Canada, V6A 3X3 In the event your Neurio needs to be upgraded or repaired, you must contact us prior to shipping it to us, and we will assign you a Return Merchandise Authorization (RMA) number. 2. To damages caused by improper operation or storage, misuse, abuse, accident or neglect, contact with liquids, extreme humidity or heat, contact with sand, dirt, food or the like, fire, or other external cause, or any other acts that are outside the course of normal consumer usage; 3. To damages caused by modification or repair to the Neurio by anyone other than one of our authorized representatives, including software/firmware modifications; 4. When serial numbers or product labels have been removed, altered or obliterated, seals have been broken, or there is any other evidence of tampering with the Neurio; 5. Where you are unable to present proof of purchase when requesting Warranty service; 6. To defects caused by normal wear and tear or otherwise due to the normal aging of the Neurio; 7. To damage caused during shipment (such claims should be presented directly to the freight forwarder or shipping company); 8. To any used Neurio purchased from a third party; or 9. Where the damage is purely cosmetic damage, including but not limited to scratches, dents or deterioration to the surface finish. DESIGN CHANGES We reserve the right to change or improve the design of the Neurio without prior notification to you. Design changes will not be implemented retroactively, and any design changes to future products does not imply the availability of an upgrade to existing units. LIMITATION OF LIABILITY EXCEPT AS PROVIDED IN THIS WARRANTY AND TO THE MAXIMUM EXTENT PERMITTED BY LAW, WE ARE NOT RESPONSIBLE FOR ANY SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING ANY DAMAGES FOR LOST DATA OR LOST PROFITS, OR FOR ANY INJURY, LOSS OR DAMAGE SUSTAINED BY ANY PERSON OR PROPERTY, THAT MAY RESULT FROM THE NEURIO FAILING TO OPERATE CORRECTLY AT ANY TIME, INCLUDING WITHOUT LIMITATION, DAMAGES RESULTING FROM THE USE, INABILITY TO USE, OR INACCURRACY OF THE NEURIO. REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS YOUR EXCLUSIVE REMEDY UNDER THIS WARRANTY. WHAT THIS WARRANTY DOES NOT COVER OUTSIDE THE UNITED STATES AND CANADA This Warranty does not apply: In countries other than the United States and Canada, the terms and conditions of this Warranty may be different. Unless a specific Neurio warranty is communicated to you in writing by us, no warranty or liability exists beyond any minimum requirements imposed by law, even though defect, damage, or 1. To damages caused by operating the Neurio outside of our published guidelines; Questions or feedback? support.neur.io FCC Part 15 This device complies with FCC Rules Part 15 operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. Changes or modifications to this device, not expressly approved by XXXX. could void the user’s authority to operate the equipment. Contains FCC ID: W72-N1LD Contains IC ID: 8253A-N1LD Industry Canada Notifications This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage; (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. IInstalling Neurio requires working with voltages that are hazardous to human health, and thus should only be done by a qualified professional. Installations should be performed in accordance with the applicable electrical code for the region in which Neurio is being installed. Whenever possible, power should be disconnected upstream from the installation location before attempting installation of Neurio. If power cannot be disconnected, high voltages may still be present, and caution must be taken to avoid injury. If Neurio is not used as instructed, its protection mechanisms may be impaired. Rules: 1. Installations should be performed by a qualified professional. 2. Do not use Neurio with voltages that exceed 240V. 3. Only install Neurio in approved breaker panels or enclosures. 4. Neurio must not be exposed to moisture, direct sunlight, extremely low or high temperatures, and conductive pollution. Consult the User Manual for Neurio’s acceptable operating environment. 5. Neurio must be installed in a location that limits access to only qualified personnel.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c145 79.163499, 2018/08/13-16:40:22 Create Date : 2019:02:11 14:14:41-08:00 Metadata Date : 2019:02:11 14:14:42-08:00 Modify Date : 2019:02:11 14:14:42-08:00 Creator Tool : Adobe InDesign CC 14.0 (Windows) Instance ID : uuid:91170e28-b70f-438b-ba36-3141454a008a Original Document ID : xmp.did:07801174072068118C148DC101155AB8 Document ID : xmp.id:bc01967f-3431-a343-89b9-d4496b24827d Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:2c6228f3-aab0-9543-83c1-2a0735ecc6fb Derived From Document ID : xmp.did:33a6037e-29c1-1841-aac3-51b3b01284c4 Derived From Original Document ID: xmp.did:07801174072068118C148DC101155AB8 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 14.0 (Windows) History Changed : / History When : 2019:02:11 14:14:41-08:00 Trim : 5.875" x 5.5" Search Text : 00bd 00be 10 15 15a 20 20a 240v 3x3 515 88 abuse acceptable access accident accordance account acknowledging act acts again against aging allow almost altered alternate america american amp antenna anyone apartments app applicable apply approved arising around assign attach attached attaching attempting attention authorization authorized availability available avoid back bar based bc beep beeps below beyond bit black blue book booklet box bracket breached breaker breakers british broken bus cable cables canada cannot care careful cases cause caused caution change changes charge check chime chirp chirps circular claim claims clean click close code codes columbia comes common communicated company conditional conditions conductive configure connect connected connecting connections connector connectors consequential consult consumer contact contents copy corners corporation correct correctly cosmetic countries course cover create credentials ct cts custom damage damages data date defect defects delivered delivery dents described description design deterioration diagrams different direct directly dirt disclaim disclaimed disconnected don done double draws drill drilling dual due duration during easier either electrical electrician empty enclosures end energized energy enough ensure enter environment equivalent even event evidence exceed except exclusive existing exists expose exposed express extend extent external extreme extremely facing failed failing falling far feedback find finger finish fire firmware fit fitness flashlight flathead follow following food foot force forth forwarder free freight future gently gloves go going guide guidelines hammer hardware having hazardous health hear heat helpful helps herein hidden hides high highly hole hosting house however human humidity ideally ignored ii iinstalling impaired implemented implied imply imposed improper improve inability inaccurracy inc incidental including indicate indicates indication indirect initial injury insert inserted inserting install installation installations installed instructed instructions interpret intro io isn items join joined jumper knockout label labeled labels latent law laws left length liability lieu limit limitation limitations limited limits line lines liquids little live local locate located location long look loop loss lost low main mains manual marrette matching materials max maximum may means mechanisms merchandise merchantability metal methods minimum minute misuse modification modifications moisture monitor mount moved near need needed needle needs neglect negligence network neur neurio neutral new next no normal north nose not note notification number numbers nut obliterated obtain off one onto open operate operating operation option optional oral order original otherwise outside own paid panel panels particular parts party pay pender performance performed period permitted person personnel phase phases phillips piggyback pilot place play please pliers point pole pollution port ports possible power powered powers present presented pressure previously prior process product products professional profits proof property protection provided pry published pull pulling purchase purchased purely purpose qualified questions read receipt recommended red region regional registered reliability remainder remedies remedy remove removed removing repair repaired repairs replace replacement replacements representatives requesting requirements requires reserve responsible result resulting retroactively return review right rma robertson room rubber rules safety sale sales sand scratches screwdriver screwdrivers screws seals secondary secure secured self send sensor sequential serial service services set shall shipment shipping short shows side sides simply single size smaller smartphone software solar something special specific st start started starting states status statutory step steps sticker storage stuck submit successful successfully suitable sunlight supplied support sure surface sustained system tab table taken tampering tap taps tear technology tell temperatures terms thick third though three thus ties time tips tone tones top touch towards trade trouble troubleshooting tuck tune turn turned twist two typical unable united units unless upgrade upgraded upstream us usage used user using usually utility v6a valid vancouver verify video videos visit voltage voltages walkthrough warning warnings warranted warranties warrants warranty watch wear welcome whenever whether white wifi wire wires wiretap wiretaps wiring within without work working workmanship writing written year Client : Neurio Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Slug Checksum : 2894756581 Slug Post Script Name : ArialMT Slug Foundry : Monotype Typography Slug Version : 001.003 Slug Outline File Size : 28783 Slug Family : Arial MT Slug Font Sense 12 Checksum : 2894756581 Slug Font Kind : PostScript Slug Kerning Checksum : 253688 Page Count : 22 Creator : Adobe InDesign CC 14.0 (Windows)EXIF Metadata provided by EXIF.tools