Ohsung Electronics URCRFX250 REMOTE CONTROL RECEIVER User Manual H
Ohsung Electronics Co., Ltd. REMOTE CONTROL RECEIVER H
Contents
- 1. USERS MANUAL
- 2. user manual
USERS MANUAL
Test Report No.: GETEC-E3-06-058 FCC Part 15 Subpart B APPENDIX H : USER’S MANUAL EUT Type: Remote Control Receiver FCC ID.: OZ5URCRFX250 Information To The User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. RFX-250 Installation Manual Optimizing Narrow Band Reception with the MRF-300 or MSC-400 However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Warning Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. Note : The manufacturer is not responsible for any Radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment. ™ COMPLETE CONTROL Universal Remote Control ™ ® 500 Mamaroneck Avenue, Harrison, NY 10528 Phone: (914) 835-4484 Fax: (914) 835-4532 www.universalremote.com COMPLETE CONTROL Universal Remote Control® RFX-250 INSTALLATION MANUAL Overview - Compatibility The RFX-250 is a narrow band RF receiver. It replaces an RFX-150 receiver in either an MRF-300 or MSC-400 system. It is tuned to receive a much narrower band and is more immune to the interference found near component racks (generated by microprocessors and power supplies). It is NOT compatible with all URC remote controls. NOTE: The RFX-250 is ONLY compatible with the current versions of the MX-3000, MX-950, MX-900 and the TX-1000 remote controls. The RFX250 is NOT compatible with MX-3000 remote controls manufactured before April 1, 2005. You can identify the build date of an MX-3000 by looking at the serial number. The first 6 digits indicate the build date. If the serial number appears as 122905 014054, the first 6 digits indicate that the remote was built on December 29, 2005. Connections Connect ONE (only) of either of the RFX250’s RF OUT connectors to ONE (only) of either of the RF IN connectors on the MRF or the MSC. When the RFX-250 can be placed within 10 feet of the MRF/MSC unit, you can utilize the cable with 3.5 mm plugs on both ends. When you need a longer wire or are connecting up to three RFX-250’s, use a cable with a minimum of three conductors. If you use CAT 5, utilize two conductors each from two of the twisted pairs for DATA and two from the other twisted pairs for 5V. Use all four of the other conductors twisted in with each pair for GND.This provides better shielding and conductivity for long runs. RFX-250 INSTALLATION MANUAL Optimizing Range and Reliability 1. Power on all AV components, dim all dimmers to 50% and power on anything that may create RF (particularly devices with high speed microprocessors or hard drives). Observe the RF LED of the RFX-250 by cupping your hand over it. If it is glowing or flickering you must relocate the RFX-250. If you cannot relocate the RFX-250, try removing its antenna. 2. Once you have found a location that is absolutely clean with everything on, test to see if the range is adequate and that macro reliability is perfect. Start with the antenna angle set to 45 degrees and positioned so that the long side of the antenna is facing the customer’s favorite seating position. Suggested antenna angle. 3. When testing, set both the remote and the MRF/MSC to the same VALID RFID#. Keep in mind that zero (0) is not a valid RFID#. Watch the STATUS LED on MRF/MSC - it should light every time you press a button on the remote. This will tell you that the signal was received and understood. Ignore the RF LED on the RFX-250 (it only indicates that a signal was received, not that it was understood). 4. If the range is inadequate, you may extend wire to any area that is not giving good results and place an additional RFX-250 in that area. Up to three RFX-250’s can be connected to each MRF/MSC. Once the RFX-250 is correctly connected, the POWER LED lights. If the RF LED lights, the RFX-250 must be moved to a new mounting location. It is receiving in-band RF INTERFERENCE. NOTE: The RFX-250 is ONLY compatible with additional RFX-250s. You cannot mix RFX-150s in a system with RFX-250s. Page 1 Page 2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 3 Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:f55c74e5-9c78-4794-81f7-286d5378a2f9 Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2006:08:10 10:56:04+09:00 Create Date : 2006:08:09 16:49:37+09:00 Metadata Date : 2006:08:10 10:56:04+09:00 Document ID : uuid:84f346c1-2366-4c6c-bb98-fb82417dae4f Format : application/pdf Title : Microsoft Word - H_User manual.doc Creator : Jeffrychoi Author : JeffrychoiEXIF Metadata provided by EXIF.tools