Omega Research and Development 4410 Keyless Entry and Security User Manual 1

Omega Research and Development Inc Keyless Entry and Security 1

Contents

User Manual 1

Download: Omega Research and Development 4410 Keyless Entry and Security User Manual 1
Mirror Download [FCC.gov]Omega Research and Development 4410 Keyless Entry and Security User Manual 1
Document ID790203
Application IDCMSDEl2eFHk4lWlQE5llpg==
Document DescriptionUser Manual 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize180.27kB (2253362 bits)
Date Submitted2007-05-09 00:00:00
Date Available2007-05-09 00:00:00
Creation Date2007-05-09 14:20:36
Producing SoftwareAcrobat 5.0 Image Conversion Plug-in for Windows
Document Lastmod2007-05-09 14:20:53
Document TitleUser Manual 1
Document CreatorAcrobat 5.0 Image Conversion Plug-in for Windows

"and Installafimu
Manual
Monzw.
KQ-Mundill ss
“4 \ a].4.mlm\
MODEL: AL-ZOOO-E
l] ==
“ffi _' g TURBO TIMER
B§j e CoolYour'Ihl-bo...
-' I
(AM 330/190“ “kph“, rmmmm Lack (AU—Tum)
STR—EUJD m sxmhc ngnm
STRJUZI) zz Mmhc “gum Buck L p mm“ (on);
Installation Instructions
How To Program Remote Control . .
How To Program Features.
Programmable Features .
erlng Dlagram ...... ..
Door Lock/Unlocking Systems ............ 14
Owner’s Guide
Arming the System
Disarming the System .
Emergency Override .
System Armed & Activated
Panlc ..
- Sensor By-Pass
Auxiliary Channel
3rd Channel
Remote Controlled An Carjack
Anti—Carjacking
Valet Mode
LED Status Indlcator .
Auxillary Sensor St Prewarn ........
This devlce complies wnn par! la or the FCC Rules
Operatlon ls sublecl lo the following two cohdltlohs: (l)
This devlce may not cause harmlul lhlerlerenoe ahd, (z)
Thls devlce must accept any lntarterenoe recelved.
lhclddlhglhterrerehceihatmaydauseohdeslredoperauoh
The mahulacturer is hot responslble l‘Drany radio orTV
thtenerenee caused by uhauthehzed modlficallons Iolhls
equlpment Such modlficatlons could void the user's
authorlty to operate the eodlpmehi
mmmwmmmmwmbeu
Table or Contents
Remote Co
roI Qu' k Reference Gu
Arming: Press & Release the “Lock" button
rm 0 f l i mttrusm».vj
Emergency Override:
mar WNW
w sEconns
(3)
szss a mass
mar eunoN
Panic: Press & Hold the “Lock" Button for 3 Sec's, with the ignition “Off"
U ‘Wm\ no “so
"0 O
hold 3 seconds
Shock Sensor & Prewarn B ass: ‘
1)Arm the alarm by, Pressing & Releasing the "Lock" button
2) VMthin 2 seconds Press & Release the Middle button.
egg (9
To Activate the Auxiliary Channel: Press & Hold The Middle
Silent Arming: Press 8. Release the Middle button Twice in 3 sec.
mt mnhlno hams
@\
"O #0
wk mu on torn
ll» Lowzcrml
Button for 3 Seconds
“WWW“, amlrmmmuml
\s/2_23
\ / Um elem rm
‘O or
hold 3 seconds
To Activate the 3rd Channel: Press & Hold The Button
' 0/0
file M
“0/0-
mwr col
for 3 Seconds
WT f \ r
'0— 0
To Activate Remote Anti-Car'ack: (programmable feature we)
Press & Hold the button, for 3 Secs, with the ignition “On"
Hold 3 seconds
Page 2
Ar ng the Alarm
The system may be "Armed" by any of 3 methods:
1) Remote Control Arming: Press & Release the “Lock” button
m; 5m mo
01 sh me
as PAinNm rims
N fé‘m\ “(ammo
;n 0 77 I O I T
“mowing“
,r; some»
2) SILENT Remote Control Armin : Press & Release the Middle
button Twice within 3 seconds
m mm trams
. flxr
:o+o:
’ r cowicrmi
Ugon Arming: - The siren Wl|| chirp one time. (3 times if there is open zone)
- The parking lights will flash once.
~ The doors will lock. (If an optional interface is connected)
- The starter interrupt will engage.
- The LED Status Indicator will begin to flash slowly.
- Ifa zone is open, (for example a car door), when arming, the alarm will still arm,
but will bypass the open zone until the zone is secured (siren will chirp 3 times).
3) To Passively Arm: Turn Ignition “Off”, Then Close all Doors.
Automatic “Last DoorArming" is a programmable feature which allows the alarm
to arm itself and, If desired, lock the doors upon arming.
If on, anytime the ignition is turned off, and then a door is opened and closed:
- The Siren will chirp once to confirm arming countdown has begun.
- The LED Status Indicator will begin to flash rapidly.
Thirty seconds later:
- The siren will chirp & the lights will flash once.
- The LED Status Indicator will begin to flash slowly.
- The starter interrupt will engage.
- The alarm is now fully armed. The doors will lock at this time, if programmed to
do so. and if the vehicle is equipped.
- The system can not Last DuorArm if a protected zone is open Should a ve-
hicle door be opened during the arming countdown, the countdown will stop and
start over again when the door is closed. AUTO REARM (programmable) allows
theAIarm to Rearm itself, if it is Disarmed and a vehicle door is not opened.
Disarming the Alarm
The system may be "Disarmed" by any of 3 methods:
1) Remote Control Disarmin : Press & Release the “Unlock" button
5- 0 fie—D I'émfifi‘g'lhlliéff
2) SILENT Remote Control Disarmin : Press & Release the Middle
“~" button Twice within 3 sec
trr
. 0 l 0 WM
irmwsmnr
Ugon Disarm: - The siren will chirp twice. (4 Chllps if alarm has activated 8. reset)
- The parking lights will flash twice. (4 times if alarm has activated)
' The doors will unlock. (If an optional interface is connected)
- The starter interrupt will disengage.
- The LED Status Indicator begins flashing rapidly for Automatic
Ream-ring, until alarm Rearms or a vehicle door is opened.
ZSTAGE DISARM: If Disarming the alarm while it is triggered (siren sounding), the
first press of any remote control button will only silence the siren/hem. A second
press of the “Unlock" button will Disarm the alarm.
IMMOBILIZER MODE: If this mode is programmed “On", the starter interrupt will
remain engaged afterthealarm is Disarmed, until the ignition is turned “On“ and you
Press & Release the Valet button. (Refer to programmable feature " 5)
To Start Vehicle: ,
1. Disarm the alarm, then Turn "On” the vehicle’s ignition t— 1 7,3
2. Press & Release the Valet Button. Q ""
Emergency Override
Step 1: With the system in the armed condition, enterthe vehicle via the driver's
door (be aware that the alarm will trigger when the door is opened).
Step 2: _ Using your key, turn the vehicle's ignition to the "On” position.
Step 3: Within 10 seconds, Press 8. Release the Valet/ Override Switch.
®
Page 3
Page 4
System Ared & Activated
Regardless ofmethod used to Arm the alarm, once Armed, the alarm will monitor
all protected zones, and if an intrusion attempt is detected it will activate, or
“trigger".
A trigger consists of the following:
- The electronic siren, or optionally the vehicle's horn, will start sounding.
- The exterior parking lights will flash on and off repeatedly.
An activation has a 30 second duration unless the system is disarmed using the
remote control or the Valet /Override switch. If all protected zones are secure at
the end of the trigger, the system will stop and rearm itselfto detect further entry
attempts. Ifa protected zone is still open atthe end ofthe trigger cycle, the alarm
will continue to re»trigger itselffor up to six activated cycles before it resets itself
and ignores the violated zone.
Remote Panic Operation
Should it be needed in a threatening situation, or you feel the need to attract
attention, the alarm can be triggered using the remote control. Youralarm fea»
tures “Panic Mode", which allows you to activate “Panic" from the “Arm/Lock"
button.
To Activate Remote Panic: Press & Hold the “Arm/Lock" Button,
for 3 seconds, with the ignition “Off”.
ms mm is i s
i“ O 7—D
Sensor By-pass
Hold 3 seconds
The shock sensor & Prewarn zone can be by-passed using the remote
control. This may be useful in stormy weather.
1) Arm the alarm by, Pressing & Releasing the “Lock" button.
2) Within 2 seconds, Press & Release the Middle “
(D
' button.
Then
- The siren will chirp once to confirm sensor has been by—passed.
- Upon Disarming the alarm, the sensor zone will reset.
The Auxiliary Channel
The Auxiliary Channel may be used to operate an optional function. Possibili-
ties include remote trunk release, remote car starting, or an on-demand re-
mote window roll-up interface. Please see your Omega dealer for details on
available options.
To Activate the Auxilia Channel:
Press & Hold the Middle Button for 3 Seconds.
ow mazmm
\ em /
a: G - -o r
- The alarm will Disarm upon activating the Auxiliary channel.
- The Auxiliary Channel cannot be activated if the vehicle's ignition is "On".
The 3rd Channel Auxiliary Output
The programmable 3rd Channel may be used to operate an optional function.
such as a remote start unit or an on-demand remote window roll-up interface.
Please see your Omega dealer for details on available options.
To Activate the 3rd Channel:
Press & Hold the button for 3 Seconds.
» The 3rd Channel can be programmed to Supply 3 (-) output when the alarm
is Armed to operate a Window Roll-Up module (Programmable feature “ 12).
Remote Ant Carjack
The Anti-Carjacking mode can be activated using the remote control.
- Refer to next page for sequence details. (programmable feature ”10)
To Activate Remote Anti-Car'ack:
Press & Hold The Button, For 3 Seconds, With The Ignition “On”.
, s I \ Hold]
, Q (965
Page 5
Page 6

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2007:05:09 14:20:53+08:00
Create Date                     : 2007:05:09 14:20:36+08:00
Creator                         : Acrobat 5.0 Image Conversion Plug-in for Windows
Producer                        : Acrobat 5.0 Image Conversion Plug-in for Windows
Page Count                      : 4
Mod Date                        : 2007:05:09 14:20:53+08:00
Creation Date                   : 2007:05:09 14:20:36+08:00
Metadata Date                   : 2007:05:09 14:20:53+08:00
Has XFA                         : No
EXIF Metadata provided by EXIF.tools
FCC ID Filing: L2M4410

Navigation menu