WIREMOLD®
Wallduct Raceway Systems
Wallduct Raceway Systems are high capacity
raceways for use in walls or ceilings. They
can be mounted to the wall surface or flush
with the wall to meet equipment layout
and room designs. The lay-in feature for
enclosure of wire and cable is ideal for use in
healthcare rooms, under raised floors, or as a
large capacity feeder for perimeter raceway.
The cover plates are easily removed for
wire and cable access. Wallduct Raceway
Systems can also be used with Trenchduct
to carry wire and cables from cabinets to
egress points anywhere on the floor or
wall. Wallduct Raceway Systems are also
available in aluminum for applications that
require nonferrous metal raceways such as
X-ray and MRI scan rooms.
Raceway Solutions for Healthcare Applications
n Constructed of galvannealed steel. The 14-gauge
galvannealed steel has a material thickness of .0785, provides
extra corrosion resistance, and is easily painted to match any
room interior.
n Available in non-magnetic aluminum material. Meets
requirements for MRI facilities in accordance with equipment
manufacturer’s specifications.
n Interior couplings. Offer improved aesthetics when
surface mounted.
n Complete line of fittings. Lowers installation costs with
fittings that can address field conditions and require minimal
field modifications.
n Bodies and covers shipped unassembled. No disassembly
required before starting system installation.
n 10" [254mm] and 18" [457mm] stock. Readily available
warehouse stock provides for immediate shipment of
customer orders.
n AutoCAD® capabilities for detailing project drawings.
Provides high quality detailing information with the option
of electronic communication for a quicker, more accurate
exchange of information.
n Three standard widths. Provide cable and wire requirements
for most applications.
n UL Listed (UL File E4376 Base and Cover, E41751 Fittings).
Product matches equipment supplier’s specifications.
FEATURES & BENEFITS
Wallduct Steel or Aluminum Raceway with lay-in features for
enclosure of wire and cable.
ED737R11 – Updated May 2016 – For latest specs visit www.legrand.us/wiremold
Aluminum Wallduct installed in an MRI Room.
Wallduct Raceway bodies are available in multiple widths
and with flush and surface cover options.
Wallduct is commonly used in the healthcare market to feed wires
and cables from electric and communication cabinets to X-ray
and MRI equipment. See typical application shown.
Because some healthcare equipment requires
nonmetallic material in the surrounding area,
aluminum Wallduct is used in scan rooms.
The equipment and control rooms
generally use steel Wallduct.
2
Wallduct Series Raceway System Layout
Pull Box (By Others)
22
1
11
3a
7
8
9
10
3
6
4
20
4a
11 16
16a
18
12
14
5a
5
19
2
2a
17
15
Item Catalog No. Description
1 WD10W350-60 5'-0" [1524mm] Straight Length.
1a CP10-F30 30" [762mm] L Flush Cover Plate.
2 WD10W350-IL Internal Wallduct Elbow.
2a CP10-ILF Internal Wallduct Elbow Cover Flush.
3 WD10W350-HL Horizontal Wallduct Elbow.
3a CP10-HLF Horizontal Wallduct Elbow
Cover Flush.
4 WD10W350-T Wallduct T-Unit.
4a CP10-TF Wallduct T-Unit Cover Flush.
5 WD10W350-X Wallduct X-Unit.
5a CP10-XF Wallduct X-Unit Cover Flush.
6 WD10W350-ECF Wallduct End Closure.
7 VA12W250H-5 VA Style Trenchduct 12" Wide
x 2 1/2" Deep [304mm x 63mm].
8 VA12W250H-EC VA Style Trenchduct End Closure.
9 VA12W250H-LL VA Style Trenchduct
Horizontal Elbow (Left Hand).
10 VA12W-VR10 VA Style Trenchduct Vertical Riser.
11
WD10W350-CC/DO
Wallduct Cabinet Connector.
12 WD350-CP Corner Partition.
13 WD350-P60 Straight Partition.
14 WD10W350-TUN T-Unit Straight Tunnel.
15 WD10-ACPF Access Cover Plate With Grommet.
16 WD10W350-EL Wallduct External Elbow.
16a CP10W350-ELF Wallduct External Elbow Cover Flush.
17 WD10W350-FST Wallduct Flush to Surface Transition.
18 WD10W350-LTUN T-Unit Left Hand Tunnel.
19 WD10W350-XTUN X-Unit Tunnel.
20 T250HZP-5 Trenchduct Partition.
21 VA12W-VL10 Trenchduct Vertical Riser
22
WD10W350-FCCF
Flanged Cabinet Connector Flush.
23
WD10W350-SWTS
Sweep Surface Tee.
24 WD-10CDO Ceiling Drop Out.
25 WD350-R04 Wallduct Reducer.
26
WD18W350-SWCCS
Sweep Cabinet Connector Surface.
27 WD10W350-SES Sweep Elbow Surface.
Wallduct and Trenchduct Legend
1a
13
27
41
26
25 24
23
21
Cabinet (By Others)
Wallduct can be installed in the wall exposing only the cover
plate, or it can be wall mounted exposing the entire surface.
Wallduct may also be installed overhead to connect cables/
wires between rooms. Trenchduct can be used in combination
with Wallduct as a feeder or for access points in the floor to feed
equipment. Diagram below is for illustration only. It does not
portray typical installation of products
Typical MRI Room Layout.
Scan Room Control Room
Equipment
Room
Wallduct Series Raceway Product Notes
To attach Wallduct Series Raceway to Trenchduct, use vertical risers as shown in the current version of ED738. All field cut
openings in Wallduct Series Raceway should be grommeted as needed to protect edges from cutting cables and wires. Order
Catalog # 686039-100FT.
Contact factory for availability of other sizes of Wallduct Series Raceway.
Catalog No./Item Description/Specifications
Bodies “A” Straight Wallduct With Removable Cover Plates –
WD06W350-60 6" [152mm] Bodies include two coupling angles and assembly screws.
WD10W350-60 10" [254mm] Bodies are 5' [1.3m] long and can be field cut to length.
WD18W350-60 18" [457mm] Surface flush covers are 30" [762mm] long. Two covers required
per body. See page 10 for wire/cable fill capacity information.
Surface Covers “B”
CP06-S30 6" [152mm]
CP10-S30 10" [254mm]
CP18-S30 18" [457mm]
Flush Covers “B”
CP06-F30 8" [203mm]
CP10-F30 12" [305mm]
CP18-F30 20" [508mm]
3
Wallduct Series Raceway Bodies and Covers Ordering Information
3 1⁄2"
[89mm]
B
A – End View
(Flush Cover Shown)
60"
[1524mm]
B 30"
[762mm]
30"
[762mm]
NOTE: To order aluminum products, add the letter “A” to the beginning of the catalog number.
Catalog No./Item Description/Specifications
WD350-P60 Straight Partition
Used to separate services.
Includes assembly screws
for field installation.
NOTE: Add the letter “A” in front
of Catalog No. for
aluminum.
WD350-CA Coupling Angle
Used for connecting two
pieces of Wallduct. Includes
assembly screws. Two coupling
angles included with every
straight body assembly.
NOTE: Add the letter “A” in front
of Catalog No. for
aluminum.
Catalog No./Item Description/Specifications
“A” Wire Retainer
WD06-WR 6" [152mm] Used to hold wires in place
WD10-WR 10" [254mm] during installation and to close
WD18-WR 18" [457mm] gap between cover plates if
more than 1/8" [3.2mm]. Snap
in place prior to installing cover
plates.
NOTE: Add the letter “A” in front
of Catalog No. for
aluminum.
WD350-CP Corner Partition – Used in
horizontal elbow to form
corner partition. Assembly
screws included. Two wire
retainers are included with
every straight body assembly.
60"
[1525mm]
3 1/4"
[83mm]
Wallduct Series Raceway Body Accessories Ordering Information
1 1⁄2"
[38mm]
A
3 3⁄16"
[81mm]
2"
[51mm] 1 1⁄2"
[38mm]
4"
[102mm]
9/16"
[14.3mm]
3 1/4"
[83mm]
NOTE: To order aluminum products, add the letter “A” to the beginning of the catalog number.
44
Catalog No./Item Description/Specifications
Surface End Closures “A” “B” End Closure – Used to close off end of
WD06W350-ECS 6" [152mm] 6" [152mm] Wallduct run. Includes assembly screws.
WD10W350-ECS 10" [254mm] 10" [254mm]
WD18W350-ECS 18" [457mm] 18" [457mm]
Flush End Closures “A” “B”
WD06W350-ECF 6" [152mm] 8" [203mm]
WD10W350-ECF 10" [254mm] 12" [305mm]
WD18W350-ECF 18" [457mm] 20" [508mm]
Wallduct Series Raceway End Closure Ordering Information
1"
[25mm]
A
B
3 1⁄2"
[89mm]
NOTE: To order aluminum products, add the letter “A” to the beginning of the catalog number.
Catalog No./Item Description/Specifications
Bodies “A” 45° Elbow – Used to change direction
WD06W350-HL45
6" [152mm] of Wallduct runs 45° on same plane. Includes one
WD10W350-HL45
10" [254mm] pair of coupling angles, one retainer, and assembly
WD18W350-HL45
18" [457mm] screws. Complete unit requires one body and one
cover plate.
Surface Covers “A”
CP06-HLS-45 5 5/8" [143mm]
CP10-HLS-45 7 1/4" [185mm]
CP18-HLS-45 10 1/2" [270mm]
Flush Covers “A”
CP06-HLF-45 6" [153mm]
CP10-HLF-45 7 3/4" [196mm]
CP18-HLF-45 11" [280mm]
Bodies “A” Horizontal Elbow – Used to change direction
WD06W350-HL 6" [152mm] of Wallduct runs 90° on same plane. Includes one
WD10W350-HL 10" [254mm] pair of coupling angles, one retainer, and assembly
WD18W350-HL 18" [457mm] screws. Complete unit requires one body and one
cover plate.
Surface Covers “B”
CP06-HLS 7" [178mm]
CP10-HLS 11" [279mm]
CP18-HLS 19" [482mm]
Flush Covers “B”
CP06-HLF 8" [203mm]
CP10-HLF 12" [305mm]
CP18-HLF 20" [508mm]
Bodies “A” Internal Elbow – Used to connect vertical and
WD06W350-IL 6" [152mm] horizontal run at 90° when cover plates are on
WD10W350-IL 10" [254mm] inside of run. Includes one pair of coupling
WD18W350-IL 18" [457mm] angles, wire retainer, and assembly screws.
Complete unit requires one elbow body and
Surface Covers “B” one cover plate.
CP06-ILS 6" [152mm]
CP10-ILS 10" [254mm]
CP18-ILS 18" [457mm]
Flush Covers “B”
CP06-ILF 8" [203mm]
CP10-ILF 12" [305mm]
CP18-ILF 20" [508mm]
Wallduct Series Raceway Fittings Ordering Information
3 1⁄2"
[89mm]
AA
B
B
B
A
A
A
3 1/2"
[89mm]
NOTE: To order aluminum products, add the letter “A” to the beginning of the catalog number.
Catalog No./Item Description/Specifications
Bodies “A” External Elbow – Used to connect vertical and
WD06W350-EL 6" [152mm] horizontal run at 90° angle when cover plates are
WD10W350-EL 10" [254mm] on outside of run. Includes attached coupling angles,
WD18W350-EL 18" [457mm] wire retainer, and assembly screws. Complete unit
requires one elbow body and two cover plates.
Surface Covers “B” Flush and surface cover catalog numbers include
CP06W350-ELS 6" [152mm] two covers.
CP10W350-ELS 10" [254mm]
CP18W350-ELS 18" [457mm]
Flush Covers “B”
CP06W350-ELF 8" [203mm]
CP10W350-ELF 12" [304mm]
CP18W350-ELF 20" [508mm]
Bodies “A” Internal External Elbow – Internal elbow used to
WD06W350-IEL 6" [152mm] change direction 90° while also allowing for a change
WD10W350-IEL 10" [254mm] in coverplate orientation. Complete unit requires one
WD18W350-IEL 18" [457mm] body and one cover plate.
Surface Covers “B”
CP06W350-IELS 6" [152mm]
CP10W350-IELS 10" [254mm]
CP18W350-IELS 18" [457mm]
Flush Covers “B”
CP06W350-IELF 8" [203mm]
CP10W350-IELF 12" [304mm]
CP18W350-IELF 20" [508mm]
Bodies “A” T-Unit – Used to connect a second run of Wallduct
WD06W350-T 6" [152mm] at 90° angle to first run. Includes one pair of coupling
WD10W350-T 10" [254mm] angles, one wire retainer, and assembly screws.
WD18W350-T 18" [457mm] Complete unit requires one body and one cover plate.
Surface Covers “B”
CP06-TS 7" [178mm]
CP10-TS 11" [279mm]
CP18-TS 19" [482mm]
Flush Covers
CP06-TF 8" [203mm]
CP10-TF 12" [304mm]
CP18-TF 20" [508mm]
WD10W350-TUN 11 7/8" [301mm] T-Unit Straight Tunnel – Provides 3" [76mm] straight
WD18W350-TUN 19 7/8" [504mm] through compartment for one service with crossover
for a second service. Assembly screws included.
NOTE: Not available for 6" [162mm] wide Wallduct.
5
Wallduct Series Raceway Fittings Ordering Information
5
A
B
NOTE: To order aluminum products, add the letter “A” to the beginning of the catalog number.
3 1⁄4"
[83mm]
3"
[76mm]
A
B
AA
3 1/2"
[89mm]
A
B
Catalog No./Item Description/Specifications
“A” Right Hand Tunnel – Used in conjunction
WD10W350-RTUN 7 7/8" [200mm] with straight partition to form a 90° angle –
WD18W350-RTUN 15 7/8" [403mm] 3" [76mm] compartment with crossover in
T-Unit. Assembly screws included.
NOTE: Not available for 6" [162mm] wide Wallduct.
“A" Left Hand Tunnel – Used in conjunction
WD10W350-LTUN 7 7/8" [200mm] with straight partition to form a 90° angle –
WD18W350-LTUN 15 7/8" [403mm] 3" [76mm] compartment with crossover in
T-Unit. Assembly screws included.
NOTE: Not available for 6" [162mm] wide Wallduct.
WD10W350-3TUN T-Unit Tunnel – Provides three equal
WD18W350-3TUN compartments for separation of services
in T-Unit. Assembly screws included.
Purchase partition Catalog No. WD350-P60
separately to complete installation.
NOTE: Not available for 6" [162mm] wide Wallduct.
Bodies “A” X-Unit – Used to connect two intersecting runs
WD06W350-X 6" [152mm] of Wallduct at a 90° angle. Includes one pair of
WD10W350-X 10" [254mm] coupling angles, one wire retainer, and assembly
WD18W350-X 18" [457mm] screws. Complete unit requires one body and one
cover plate.
Surface Covers “B”
CP06-XS 8" [203mm]
CP10-XS 12" [304mm]
CP18-XS 20" [508mm]
Flush Covers “B”
CP06-XF 8" [203mm]
CP10-XF 12" [305mm]
CP18-XF 20" [508mm]
“A” X-Unit Crossover – Used to provide a 90°
WD10W350-XTUN 6 7/8" [174mm] angle – 3" [76mm] compartment with crossover
WD18W350-XTUN 14 7/8" [377mm] in X-Unit. Assembly screws included.
NOTE: Not available for 6" [162mm] wide Wallduct.
6
Wallduct Series Raceway Fittings Ordering Information (Continued)
3 1⁄4"
[83mm]
3"
[76mm]
A
BB
AA
3 1/2"
[89mm]
NOTE: To order aluminum products, add the letter “A” to the beginning of the catalog number.
Partitions
Partitions
Bridge Tunnel
Partitions
3 1⁄4"
[83mm]
3"
[76mm]
A
3"
[76mm]
3 1⁄4"
[83mm]
1"
[25mm]
A
Catalog No./Item Description/Specifications
WD10W350-3TUN X-Unit Tunnel – Provides three equal
WD18W350-3TUN compartments for separation of services
in X-Unit. Assembly screws included.
Purchase partition, Catalog No. WD350-P60
separately to complete installation. Complete
X-Unit assembly requires two X-unit tunnel units.
NOTE: Not available for 6" [162mm] wide Wallduct.
“A” Sweep Elbow – Used to connect vertical and
WD06W350-SES 6" [152mm] horizontal runs of Wallduct at a 90° angle with
WD10W350-SES 10" [254mm] a 45° internal sweep radius. Includes one pair
WD18W350-SES 18" [457mm] of coupling angles and assembly screws. For
partition use Catalog No. WD350-PSE Series.
NOTE: Not available in flush cover version.
WD350-PSE Internal Sweep Elbow Partition – Used with past
#WDXWX-SES to partition elbow.
“A” Reducer Coupling – Used to reduce Wallduct
WD350-RO2 2" [51mm] width by 4" [102mm] or 8" [204mm]. Two piece
WD350-RO4 4" [102mm] unit allows 18" [457mm] wide Wallduct to be
reduced to 10" [254mm] wide, or 10" {254mm]
wide to be reduced to 6" [152mm] wide. Can also
be used on other sizes as needed. Assembly
screws included.
“A” Cabinet Connector/Drop Out – Used to connect
WD06W350-CC/DO 5 3/4" [146mm] ends of Wallduct run to panel/cabinet. Also used
WD10W350-CC/DO 9 3/4" [247mm] to connect two runs of Wallduct at a 90° angle
WD18W350-CC/DO 17 3/4" [450mm] when one run butts up to the bottom or top of the
other. Assembly screws included.
7
Wallduct Series Raceway Fittings Ordering Information (Continued)
Partition
Partition
Bridge
Partition
Tunnel
Partitions
A
14"
[356mm]
14"
[356mm]
3 1⁄2"
[89mm]
3 1⁄2"
[89mm]
NOTE: To order aluminum products, add the letter “A” to the beginning of the catalog number.
Two tunnels shown.
3.878"
[98.50mm]
9.987"
[253.67mm]
3 1/2"
[88.90mm]
A
3 1⁄4"
[82mm]
1"
25mm]
A
A
6”
Catalog No./Item Description/Specifications
“A” Sweep Cabinet Connector – For use
WD06W350-SWCCS 6" [152mm] with GE medical equipment. Attaches to 6" x
WD10W350-SWCCS 10" [254mm] 3 1/2" [152mm x 89mm], 10" x 3 1/2" [254mm x
WD18W350-SWCCS 18" [457mm] 89mm], or 18" x 3 1/2" [457mm x 89mm]
horizontal surface Wallduct.
NOTE: Not available in aluminum.
“A” “B” Transition – Used to form a junction between
WD06W350-FST 6" [152mm] 8" [203mm] flush and surface Wallduct at a 90° angle.
WD10W350-FST 10" [254mm] 12" [304mm] Includes assembly screws, clips, one wire
WD18W350-FST 18" [457mm] 20" [508mm] retainer and two coupling angles.
Surface Covers “A” Access Cover Plate – Two-piece cover with
WD06-ACPS 6" [152mm] grommeted hole in center. Can be installed at any
WD10-ACPS 10" [254mm] location by match drilling eight holes in duct body
WD18-ACPS 18" [457mm] flanges and attaching speed nuts. Includes
assembly screws and grommet. Use 5/16"
Flush Covers “A” [7.9mm] diameter drill for speed nuts.
WD06-ACPF 7" [178mm]
WD10-ACPF 11" [279mm]
WD18-ACPF 19" [482mm]
Sweep Tee “A” Sweep Tee Used to connect horizontal and
WD06W350-SWTS 6" [152mm] vertical runs of Wallduct at a 90° angle with
WD10W350-SWTS 10" [254mm] sweep radius. Includes one pair of coupling
WD18W350-SWTS 18" [457mm] angles and assembly screws.
NOTE: Not available in flush cover version.
8
Wallduct Series Raceway Accessories Ordering Information
A
2 1⁄2"
[64mm]
10 1⁄2"
[266mm] 8"
[203mm]
A
1"
[25mm]
BDuct Body Surface
Cover Plate
Duct Body Flush
NOTE: To order aluminum products, add the letter “A” to the beginning of the catalog number.
6"
[152mm]
3"x 8" [76mm x 203mm] Hole.
For 6" [152mm] Acess Plate,
hole size is 3" x 4" [76mm x 102mm]
A
12"
[305mm]
A
10"
[254mm]
10"
[254mm]
9
Catalog No./Item Description/Specifications
Flanged Connector “A” Flanged Cabinet Connector – Used to connect
WD06W350-FCCS 16" [406mm] end of Wallduct run to panel cabinet. Assembly
WD10W350-FCCS 22" [559mm] screws included. Use .166" [4.2mm] diameter
WD18W350-FCCS 24" [610mm] (#19 drill) for assembly.
WD06W350-FCCF 18" [4570mm] NOTE: Not available in aluminum.
WD10W350-FCCF 24" [610mm]
WD18W350-FCCF 26" [660mm]
Ceiling Drop Out “A” Ceiling Drop Out – Used to drop cables and
WD-10CDO 4" [102mm] to 5 3/4" [146mm] wires from Wallduct in ceiling to imaging
WD-10CDOD 5 1/2" [140mm] to 7 1/4" [184mm] equipment. Available in 10" [254mm] width only.
Units have adjustable depth.
Wallduct Series Raceway Accessories Ordering Information (Continued)
10"
[254mm]
A
A
6"
[152mm]
NOTE: To order aluminum products, add the letter “A” to the beginning of the catalog number.
Part No: Description/Specifications
1002412 Wallduct Replacement Hardware
Hardware bag with twelve (12)
10/32 x 7/8" pan head screws.
1000883 Wallduct Replacement Hardware
Hardware bag with eight (8)
10/32 x 1/4" pan head screws.
1002414 Wallduct Replacement Hardware
Hardware bag with twelve (12)
cover clips.
Part No: Description/Specifications
686039-100FT Wallduct Grommet – Applied to
edges of Wallduct and fittings
where cables egress to protect
against damage to cable insulation.
Packed 100' of grommet per unit.
Wallduct Series Raceway Replacement Hardware Ordering Information
Wallduct is ideal for use in
medical scan rooms.
10
Wallduct Series Raceway Wire Fill Capacity
Use these steps to determine wire fill capacity in Wallduct.
Step 1: Determine the internal raceway area by multiplying the overall width by the overall depth (subtract material thickness).
Example: Assume a raceway 10" wide by 4" deep. Subtract the material thickness from each dimension
(see below). This results in internal raceway dimensions of 9.844" (10" - 0.156") wide by 3.922"
(4" - 0.078"). The internal area for this raceway size would be 38.6 sq. in. (9.844" x 3.922").
Step 2: Determine the number of conductors allowed inside the raceway for a given type and size (types THHN and THWN are
shown in Table 1) of the conductor by multiplying the internal area (calculated in Step 1) by the number of conductors
allowed per square inch (see table 1).
Example: Calculate how many No. 6 AWG (THHN) conductors you are allowed to place in the 10" x 4"
raceway in Step 1 at 40% wire fill capacity. Multiply the internal area of the raceway by the maximum number
of wires allowed per square inch, from table 1. This results in 304 allowable cables (38.6 sq. in. x 7.89).
A 20% fill should be used for systems utilizing fittings that have sharp 90° turns. The derating factors of NEC article 310.15(B)(2)(a)
shall apply to conductors installed if the amount of current-carrying conductors exceeds 30 in number, or the sum of the cross-
sectional area of all conductors exceeds 20% of the interior cross-sectional area of the raceway. When tunnels are utilized, the
internal cross-sectional area must be further reduced by 50%. When partitions are utilized, the internal cross-sectional area must
be calculated for each individual compartment.
Deduct for Deduct for
Maximum Raceway Material Material
Width (In.) Thickness Thickness
Left & Right (Bottom)
6" – 18" Steel 0.156" 0.078"
20" – 30" Steel 0.216" 0.108"
6" – 18" Aluminum 0.200" 0.100"
20" – 30" Aluminum 0.250" 0.125"
WIRE SIZE DIAMETER AREA (In2) 40% FILL 20% FILL
AWG In. [mm] Sq. In. [Sq. mm] (Per Sq. In.) (Per Sq. In.)
14 0.111 [2.8] 0.0097 [6.3] 41.24 20.62
12 0.130 [3.3] 0.0133 [8.6] 30.08 15.04
10 0.164 [4.2] 0.0211 [13.6] 18.96 9.48
8 0.216 [5.5] 0.0366 [23.6] 10.93 5.46
6 0.254 [6.5] 0.0507 [32.7] 7.89 3.94
4 0.324 [8.2] 0.0824 [53.2] 4.85 2.43
3 0.352 [8.9] 0.0973 [62.8] 4.11 2.06
2 0.384 [9.8] 0.1158 [74.7] 3.45 1.73
Table 1 – Steel Wallduct Wire Fill Capacities for Power
DIAMETER AREA (In2) 40% FILL 20% FILL
CABLE/WIRE SIZE In. [mm] Sq. In. [Sq. mm] (Per Sq. In.) (Per Sq. In.)
UNSHIELDED 4-Pair, Cat 5e 0.220 [5.6] 0.0381 [24.6] 10 5
TWISTED PAIR 4-Pair, Cat 6 0.250 [6.4] 0.0491 [31.7] 14 7
TELEPHONE 2-Pair, 24 AWG 0.140 [3.5] 0.0154 [9.9] 20 13
4-Pair, 24 AWG 0.190 [4.8] 0.0263 [18.2] 14 7
25-Pair, 24 AWG 0.410 [10.4] 0.1321 [85.2] 3 1
COAXIAL RG58/U 0.195 [4.9] 0.0298 [19.2] 13 6
RG59/U 0.242 [6.1] 0.0459 [29.6] 9 4
RG6/U 0.270 [6.8] 0.0572 [36.9] 7 3
SHIELDED TYPE 1 0.390 [9.9] 0.1194 [77.0] 3 1
TWISTED PAIR TYPE 2 0.465 [11.8] 0.1698 [109.5] 2 1
TYPE 3 0.245 [6.2] 0.0471 [30.4] 0 4
FIBER OPTIC 2-STRAND 0.180 [4.6] 0.0254 [16.4] 10 8
4-STRAND 0.190 [4.8] 0.0263 [15.3] 14 7
6-STRAND 0.210 [5.3] 0.0346 [22.3] 11 5
FIBER ZIP CORD 0.110 [2.8] 0.0095 [6.1] 42 21
Table 2 – Steel Wallduct Wire Fill Capacities for Data/Communications
NOTE: Wire diameters can vary depending on manufacturer. Verify diameter and adjust fill capacities as
required. Values are per one square inch of Wallduct area.
11
Wallduct Series Raceway Take-Off Sheet
Project Name: _________________________________________________________
Location: ______________________________________________________________
1. Enter the correct size and width of each part number (WD"6"W"350"-60).
2. Provide correct covers, dividers, tunnels, hardware, fittings as required.
3. Provide correct part number of covers per bodies of WallDuct (two covers per WallDuct body).
WD___W___-60 Body
CP___W___-S30 Surface Cover
CP___W___-F30 Flush Cover
WD___-P60 Straight Partition
WD___-CA Coupling Angle
WD___-WR Wire Retainer
WD___-CP Corner Partition
WD___W___-ECS Surface End Closure
WD___W___-ECF Flush End Closure
WD__W___-HL45 45° Elbow Body
CP___-HLS-45 45° Elbow Surface Cover
CP___-HLF-45 45° Elbow Flush Cover
WD__W___-HL Horizontal Elbow Body
CP___-HLS Horizontal Surface Cover
CP___-HLF Horizontal Flush Cover
WD___W___-IL Internal Elbow Body
CP___-ILS Internal Elbow Surface Cover
CP___-ILF Internal Elbow Flush Cover
WD___W___-EL External Elbow Body
CP___W___-ELS External Elbow Surface Cover
CP___W___-ELF External Elbow Flush Cover
WD___W___-T T-Unit Body
CP___-TS T-Unit Surface Cover
CP___-TF T-Unit Flush Cover
WD___W___-TUN Straight Tunnel
WD___W___-RTUN Right Hand Tunnel
WD___W___-LTUN Left Hand Tunnel
WD___W___-3TUN T-Unit Tunnel
WD___W___-X X-Unit Body
CP___-XS X-Unit Surface Cover
CP___-XF X-Unit Flush Cover
WD___W___-XTUN X-Unit Crossover
WD___W___-3TUN X-Unit Tunnel
WD___W___-SES Sweep Elbow
WD___-RO2 Reducer Coupling
WD___-RO4 Reducer Coupling
WD___W___-CC/DO Cabinet Connector Drop Out
WD___W___-SWCCS Sweep Cabinet Connector
WD___W___-FST Transition
WD___-ACPS Surface Access Cover Plate
WD___-ACPF Flush Access Cover Plate
WD___W___-SWTS Sweep Tee
WD___W___-FCCS Flanged Cabinet Connector
WD___W___-FCCF Flanged Cabinet Connector
WD-10CDO Ceiling Drop Out
WD-10CDOD Ceiling Drop Out
Run #
WD___W___-60 Body
CP___W___-S30 Surface Cover
CP___W___-F30 Flush Cover
WD___-P60 Straight Partition
WD___-CA Coupling Angle
WD___-WR Wire Retainer
WD___-CP Corner Partition
WD___W___-ECS Surface End Closure
WD___W___-ECF Flush End Closure
WD__W___-HL45 45° Elbow Body
CP___-HLS-45 45° Elbow Surface Cover
CP___-HLF-45 45° Elbow Flush Cover
WD__W___-HL Horizontal Elbow Body
CP___-HLS Horizontal Surface Cover
CP___-HLF Horizontal Flush Cover
WD___W___-IL Internal Elbow Body
CP___-ILS Internal Elbow Surface Cover
CP___-ILF Internal Elbow Flush Cover
WD___W___-EL External Elbow Body
CP___W___-ELS External Elbow Surface Cover
CP___W___-ELF External Elbow Flush Cover
WD___W___-T T-Unit Body
CP___-TS T-Unit Surface Cover
CP___-TF T-Unit Flush Cover
WD___W___-TUN Straight Tunnel
WD___W___-RTUN Right Hand Tunnel
WD___W___-LTUN Left Hand Tunnel
WD___W___-3TUN T-Unit Tunnel
WD___W___-X X-Unit Body
CP___-XS X-Unit Surface Cover
CP___-XF X-Unit Flush Cover
WD___W___-XTUN X-Unit Crossover
WD___W___-3TUN X-Unit Tunnel
WD___W___-SES Sweep Elbow
WD___-RO2 Reducer Coupling
WD___-RO4 Reducer Coupling
WD___W___-CC/DO Cabinet Connector Drop Out
WD___W___-SWCCS Sweep Cabinet Connector
WD___W___-FST Transition
WD___-ACPS Surface Access Cover Plate
WD___-ACPF Flush Access Cover Plate
WD___W___-SWTS Sweep Tee
WD___W___-FCCS Flanged Cabinet Connector
WD___W___-FCCF Flanged Cabinet Connector
WD-10CDO Ceiling Drop Out
WD-10CDOD Ceiling Drop Out
Run #
NOTES
Electrical Wiring Systems
60 Woodlawn Street
West Hartford, CT 06110
Phone: 1.877.BY.LEGRAND (295-3472)
www.legrand.us
570 Applewood Crescent
Vaughan, Ontario L4K 4B4
Phone:905.738.9195
www.legrand.ca
© Copyright 2016 Legrand All Rights Reserved
ED737R11 – Updated May 2016 – For latest specs visit www.legrand.us/wiremold
NOTE: All brand and product names referenced in this document are
registered trademarks or trademarks of their respective holders.
NOTE: The paper used to print this document is an environmentally
responsible paper with 10% post consumer waste, with FSC
and SFI Chain of Custody certifications, Lacey Act complaint.
100% of the electricity used to manufacture Flo sheets is
generated with Green-e certified renewable energy.
Page 1 of 12 - 1000317256-Catalog
Page 2 of 12 - 1000317256-Catalog
Page 3 of 12 - 1000317256-Catalog
Page 4 of 12 - 1000317256-Catalog
Page 5 of 12 - 1000317256-Catalog
Page 6 of 12 - 1000317256-Catalog
Page 7 of 12 - 1000317256-Catalog
Page 8 of 12 - 1000317256-Catalog
Page 9 of 12 - 1000317256-Catalog
Page 10 of 12 - 1000317256-Catalog
Page 11 of 12 - 1000317256-Catalog
Page 12 of 12 - 1000317256-Catalog

Navigation menu