GE Control Catalog Section 1 Brochure

2016-10-06

: Pdf 1000496446-Brochure 1000496446-Brochure B5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 2

www.geelectrical.com Rev. 1/08
Prices and data subject
to change without notice
Control Catalog
1-150
NEMA Full Voltage Power Devices
NEMA Rated Full Voltage Starters - Magnetic
Section 1
Product Number Selection Instructions: See page 1-149
Open Forms Single Pole
Ambient Compensated Noncompensated
Ratings Standard Trip Standard or Quick Trip Quick Trip Front Mounting Bracket
Maximum Contact(s) Product List Price Product List Price Product List Price Product List Price
Full Load Amperes Size per Pole Number GO-10H Number GO-10H Number GO-10H Number GO-10H
27 1 1NC CR124C028 $27.00 CR124K028 $39.00 CR124K078 $27.00 CR124C0261$1.80
27 1 NO/NC (SPDT) CR124C078 $51.00 CR124K0128 $63.00 CR124K0178 $51.00 CR124C0261$1.80
45 2 1NC CR124D028 $39.00 CR124L028 $51.00 CR124L078 $39.00 CR124C0261$1.80
45 2 NO/NC (SPDT) CR124D078 $63.00 CR124L0128 $75.00 CR124L0178 $63.00 CR124C0261$1.80
90 3 1NC CR124E028 $54.00 CR124M028 $68.10 CR124M078 $54.00 284A651G0022$3.00
90 3 NO/NC (SPDT) CR124E078 $87.00 CR124M0128 $101.10 CR124M0178 $87.00 284A651G0022$3.00
135 4 1NC CR124F028 $84.00 CR124N028 $98.10 CR124N078 $84.00 284A651G0022$3.00
135 4 NO/NC (SPDT) CR124F078 $117.00 CR124N0128 $131.10 CR124N0178 $117.00 284A651G0022$3.00
270 5 1NC CR124G0112$327.00 CR124P0283$477.00 CR124P0783$327.00 Included
270 5 NO/NC (SPDT) CR124G0192$360.00 CR124P01283$510.00 CR124P01783$360.00 Included
1Bracket for one CR124K or L form is CR124K026 at $1.80, GO-10H.
2Bracket for one CR124M or N form is product number 284A651G003 (includes two thread cutting screws).
3These forms include current transformers—use on ac only.
CR124 Single-Pole Panel Mount Overload Relays
600 VAC/250 VDC
270 Maximum Amperes Continuous
Contact Ratings 1 NO or 1 NC of SPDT Type
Continuous
Carry Make Recommended Maximum Interrupting Capacity, Amperes
Amperes Amperes DC Circuits AC Circuits
AC or DC 125 V 250 V 115 V 230 V 460 V 575 V
10 30 0.35 0.17 3 1.5 0.75 0.6
Note: Normally open contact is for 25 VA carry, 250 VA make.
284A651G003 Bracket
Accessories
External Reset Kit
Enclosure NEMA Reset Distance (in.) Product List Price
Type Size Behind Panel Number GO-10H
NEMA Type 1 00-5 1 - 6 CR124X100C $21.00
NEMA Type 12
NEMA Type 4/4X 00-5 1 - 6 CR124X100D $25.00
For Single or Block Overload Relays and 200-, 300- and 400-line Starters.
Enclosed Forms NEMA Type 1
Ratings Standard Trip Front Mounting Bracket
Maximum Contact(s) Product List Price Product List Price
Full Load Amperes Size per Pole Poles Number GO-10H Number GO-10H
1 CR124C111 $69.00 CR124C0261$1.80
27 1 1 NC 2 CR124C029 $3.60
3 CR124C113 $165.00 547A849P001 $5.40
1 CR124D111 $111.00 CR124C0261$1.80
45 2 1 NC 2 CR124C029 $3.60
3 CR124D113 $231.00 547A849P001 $5.40
1 CR124E111 $156.00 284A651G0022$3.00
90 3 1 NC 2 284A651G004 $9.00
3 CR124E113 $306.00 284A651G004 $9.00
1Bracket for one CR124K or L form is CR124K026 at $1.80, GO-10H.
2Bracket for one CR124M or N form is product number 284A651G003 (includes two thread cutting screws).
www.geelectrical.com Control Catalog
Publications and Reference: See Section 17 for a
complete list of additional product-related publications
1-149
NEMA Full Voltage Power Devices
NEMA Rated Full Voltage Starters - Magnetic
Rev. 1/08
Prices and data subject
to change without notice
Section 1
Application
Single-pole overload relays are used to provide overload protec-
tion for dc and single-phase ac motors having full load currents
of 270 Amperes or less; also, three relays for 3-phase motors
requiring quick-trip protection.
Optional NO-NC contact (SPDT) can be connected to alarm circuit
to signal when relay trips.
Features
—Positive Overload Protection; relay utilizes a bimetallic strip
and heater which closely simulates thermal characteristics
of motor.
—Manual or Automatic Reset; on normally-closed contact
forms1–simple spring clip shift from one to the other.
—Trip Current Adjustment; knob can be set from 85 to 115% of
nominal heater trip rating.
—Ambient Compensated Forms; for use where motor and relay
are not in the same ambient.
—Quick Trip Forms; for use with motors with low ratio of locked-
rotor to running current and/or short allowable stall time.
—Front Mounting; is provided by use of mounting brackets for 1,
2, or 3 relays.
—Optional Back Mounting; requires no brackets.
—Front-Replaceable Heaters; provide change of trip current
rating in approximately 10% steps.
1Not on CR124M or CR124N forms.
Product Number Selection Instructions
1. Order relay and accessories by complete product number.
Example: An ambient compensated relay with 1 NO-1 NC
contact for quick-trip application with less than 27 Amperes
full-load current—order CR124K0128 at $63.00, GO-10H.
Also order quick-trip overload heater from page 1-161.
Reference Publications
Instructions GEH-4729 (CR124C, D)
GEH-2543 (CR124E, F)
Heater Selection Guide GET-2681
Instructions GEH-2487 (CR124K, L)
GEH-2515 (CR124M, N)
GEH-4734 (CR124X)
Overload Relays for Panel Mounting (CR124) – Contents
Application Information and Selection Instructions.............1-149
Single-Pole, 270 Maximum Amperes Continuous .................1-150
Outlines and Dimensions ..................................................................1-151
CR124 Single-Pole Panel Mount Overload Relays
600 VAC/250 VDC
270 Maximum Amperes Continuous
CR124E028 Overload Relay