Resi 2004

136942-Catalog 136942-Catalog 136942-Catalog 785901 Batch4 unilog cesco-content

2014-06-03

: Pdf 102143-Attachment 102143-Attachment 785901 Batch4 unilog

Open the PDF directly: View PDF PDF.
Page Count: 72

DownloadResi 2004
Open PDF In BrowserView PDF
Residential
Products Catalog

Headquartered in Palatine, Ill., the
North American Operating Division of
Schneider Electric had sales of $2.7
billion in 2002. The North American
Operating Division is one of three geographic divisions of Schneider Electric,
headquartered in Paris, France, and
markets the Merlin Gerin, Square D and
Telemecanique brand products to
customers in the United States, Canada
and Mexico. In the United States,
Schneider Electric is best known by its
flagship Square D brand, with
Telemecanique becoming increasingly
known in the industrial control and
automation markets and supported by
many Square D distributors. For 100
years, Square D has been a marketleading brand of electrical distribution
and industrial control products, systems
and services. Schneider Electric is a
global electrical industry leader with
2003 sales of approximately $9.9 billion.
It is the world’s leading manufacturer
of electrical distribution, industrial
control and automation products and
systems, and the only electrical
manufacturer dedicated solely to the
distribution and control of electricity.

The SQUARE D Multi-Link System is a comprehensive home network
solution that allows you to maximize the use of your home technology today
and ensure that your home has the infrastructure required to support
tomorrow’s advances. Whether you need greater functionality for your home
office, a local area network, high-speed internet access, or more convenience
in accessing your home entertainment equipment, the SQUARE D Multi-Link
System offers a reliable, easy-to-use, and affordable solution.
With the SQUARE D Multi-Link System, you will be able to:
■

Control
video
R E
Sequipment
I D EfromNanyTroom
I via
A theLunique infrared remote
control technology

■

Add system functionality at any time - The SQUARE D Multi-Link System
features the industry’s most open design, allowing you to create your own
RESIDENTIAL CONSTRUCTION
custom system, whether using Square D option upgrades or third-party
add-ons. Even with today’s technological advances, you will never have to
Scheider
Electric
is System
the leading
supplier
of electrical
worry
about your
Multi-Link
becoming
out dated.
equipment for residential construction in the United
Know you are protected by the leader in electrical protection - Today’s
States, Canada and Mexico. Focused residential sales
homeowner has more costly electronic equipment than ever before.
and that
marketing
teams
concentrate
on serving
residential
Protect
equipment
with our
SURGEBREAKER
PLUS Multi-Path
Surge
Protector. A single
perfect complement
to your SQUARE
D Multi-Link
contractors,
and multi-family
home builders,
System, the SURGEBREAKER PLUS provides surge protection up to
manufactured
electrical
20,000
volts for your housing
telephone,companies,
video and electrical
lines - wholesale
all backed by
a 5-year
$50,000 warranty.
distributors
and home improvement retailers.

P R O D U C T S

■

Load Centers and Circuit Breakers
Load Centers and Circuit Breakers Product Information . . . . . . . . . . . . . . 2
QO® Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Plug-On Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
QO Circuit Breaker Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
QO Load Centers
Series Rating Class 1100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Indoor - Main Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Indoor - Main Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Rainproof - Main Lug, Main Breaker. . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Three Phase - Main Lug, Main Breaker . . . . . . . . . . . . . . . . . . . . . . . 10
Special Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Voltage Testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Homeline® Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Homeline Load Centers
Series Rating Class 1170. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Indoor - Main Lug, Main Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Rainproof - Main Lug, Main Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . 18
QO and Homeline Load Centers
Indoor - Dimensions, Knockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Rainproof - Dimensions, Knockouts, Bolt-On Hubs . . . . . . . . . . . . . . . 20
QO Load Centers Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Three Phase Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Homeline Load Centers Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . 23

Table of
C O N T E N T S

Combination Service Entrance Devices
CSED Product Information . . . . .
Rainproof - Meter-Mains . . . . .
Rainproof - All-In-Ones . . . . . .
Circuit Breakers, Accessories. .
Dimensions . . . . . . . . . . . . . . .
Enclosed Molded Case Switches.
Circuit Breaker Enclosures . . . . .

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

24
25
26
27
28
29
29

Surge Protection
Surge Protection Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . 30
TVSS and Surge Arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Air Conditioning Disconnects
Air Conditioning Disconnects Product Information
Air Conditioning Disconnects . . . . . . . . . . . . . . . .
Voltage Tester . . . . . . . . . . . . . . . . . . . . . . . . . . .
Servicepak Power Outlet Panels . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . 32
. . . . . . . . . . . . . . . . . 32
. . . . . . . . . . . . . . . . . 33
. . . . . . . . . . . . . . . . . 34

Structured Wiring
Square D Structured Wiring Product Information . . . . . . . . . . . . . . . . . . 35
Square D Multi-Link Structured Wiring System . . . . . . . . . . . . . . . . . 36-37

Metering
Metering Product Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Individual Meter Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Ganged and Test Block Sockets and Accessories . . . . . . . . . . . . . . . . . 40
Individual Ganged and Test Block Sockets Dimensions . . . . . . . . . . . . . 41
MP Meter-Pak Meter Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42-43
MP Meter-Pak Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
EZ Meter-Pak® Meter Centers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45-50
EZ Meter-Pak Meter Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
EZ Meter-Pak SCCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52-53

Switches
Safety Switches and Disconnects Product Information . . . . . . . . . . . . . . 54
General Duty Safety Switches
Light Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Accessories, Lug Data and Dimensions . . . . . . . . . . . . . . . . . . . . . . . 56
Double Throw Safety Switches
Fusible and Not Fusible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
240 Volt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Application Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60-61
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Square D Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63-64
Square D Conditions of Sale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65-68
1

Load Centers &
C I R C U I T

B R E A K E R S

QO® Load Centers and Circuit Breakers
Square D load centers are the leading choice of electrical contractors
and electricians. Every feature of the QO Load Center was designed to
provide clear advantages. QO Circuit Breakers also have features no other
manufacturer can offer. These quality, industry exclusive products keep
Square D ahead of the competition and are builders’ and electrical
contractors’ first choice in electrical protection.
Load Center Features:
■ Shielded Copper Bus Bar.
■ Available in single and three phase.
■ Ground Bar is included with all main lugs load centers with three
mounting locations.
■ Convertible Mains let you meet changing job-site requirements.
■ 22,000/10,000 AIR standard series connected rating.
■ Tangential main service knockouts.
■ Enclosure rotates for top or bottom feed to reduce service cable waste.
QO Circuit Breaker Features:
■ Qwik-Open® circuit breaker protection.
■ Exclusive Visi-Trip® red indicator.
■ Quick make - quick break mechanism.
■ Plug-on design, easy to install.

Homeline® Load Centers and Circuit Breakers
Homeline Load Centers and Circuit Breakers are built with the same
Square D quality you have come to expect at a price that makes them
the best value in their class. Feature for feature, Homeline products
outclass the competition.
Features include:
■ Straight-In Mains.
■ Convertible Mains let you meet changing job-site requirements.
■ Split-branch neutral with up to 50% more terminations than required.
■ Bus and interior assembly is among the most rugged in the industry.
■ Three ground bar mounting locations.
■ 22,000/10,000 AIR standard series connected rating.
■ Tangential main service knockouts.
■ Enclosure rotates for top or bottom feed to reduce service cable waste.

2

QO® Circuit Breakers
with VISI-TRIP® Indicator
Class 730, 731, 733

www.SquareD.com
For the most up-to-date information
QO 1-pole

QOT 1-pole
Tandem

QO Miniature Circuit Breakers
Square D QO miniature circuit breakers are plug-on products for use in QO load centers.
Plug-On Circuit Breakers—UL Listed Amperes Interrupting Rating (AIR) In Amperes RMS Symmetrical
Amperes
Ratinga

1-pole—120/240 Vac
Catalog Number

Price

2-pole—120/240 Vac
Common Trip
Catalog Number
Price

2-pole—240 Vac b
Common Trip
Catalog Number
Price

Three-pole—240 Vac
Common Trip
Catalog Number
Price

1 Space Required

1 Space Required

QO 2-pole

QO Three-pole

2 Spaces Required 3 Spaces Required
QO2200 2-pole
200 A

4 Spaces Required

10
QO110
$19.40
15
QO115 cd
19.40
20
QO120 cd
19.40
25
QO125 c
19.40
30
QO130 c
19.40
35
QO135 c
19.40
40
QO140 c
19.40
45
QO145 c
19.40
50
QO150 c
19.40
60
QO160 c
19.40
70
QO170 c
44.70
80
...
...
90
...
...
100
...
...
110
...
...
125
...
...
150
...
...
175
...
...
200
...
...
Molded Case Switch 60 A max.–240 Vac
Molded Case Switch 100 A max.–240 Vac

QO210
QO215 c
QO220 c
QO225 c
QO230 c
QO235 c
QO240 c
QO245 c
QO250 c
QO260 c
QO270 c
QO280c
QO290c
QO2100c
QO2110c
QO2125c
QO2150ce
QO2175ce
QO2200ce
...
...

$ 44.70
44.70
44.70
44.70
44.70
44.70
44.70
44.70
44.70
44.70
89.00
126.00
126.00
126.00
285.00
285.00
327.00
327.00
327.00
...
...

...
QO215H
QO220H
QO225H
QO230H
...
QO240H
...
QO250H
QO260H
QO270H
QO280H
QO290H
QO2100H
...
...
...
...
...
QO200
QO2000f

...
$133.00
133.00
133.00
133.00
...
133.00
...
133.00
133.00
149.00
210.00
210.00
210.00
...
...
...
...
...
46.90
133.00

QO310
QO315 c
QO320 c
QO325 c
QO330 c
QO335 c
QO340 c
QO345 c
QO350 c
QO360 c
QO370c
QO380c
QO390c
QO3100c
...
...
...
...
...
QO300
QO3000f

$ 165.00
165.00
165.00
165.00
165.00
165.00
165.00
165.00
165.00
165.00
210.00
244.00
244.00
244.00
...
...
...
...
...
165.00
244.00

QO215VH gc
QO220VH gc
QO225VH gc
QO230VH gc
QO240VH gc
QO250VH gc
QO260VH gc
QO270VH gc
QO280VH gc
QO290VH gc
QO2100VH gc
QO2110VH ghc
QO2125VH ghc
QO2150VH gce
QO2175VH gce
QO2200VH gce

$ 97.00
97.00
97.00
97.00
97.00
97.00
97.00
149.00
210.00
210.00
210.00
689.00
689.00
707.00
707.00
707.00

...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...

...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...

QO315VH gc
QO320VH gc
QO325VH gc
QO330VH gc
QO340VH gc
QO350VH gc
QO360VH gc
QO370VH gc
QO380VH gc
QO390VH gc
QO3100VH gc
...
...
...
...
...

$ 247.00
247.00
247.00
247.00
247.00
247.00
247.00
318.00
353.00
353.00
353.00
...
...
...
...
...

QOH240cf
QOH245cf
QOH250cf
QOH260cf
QOH270c
QOH280c
QOH290c
QOH2100c
QOH2110cf
QOH2125c

$211.00
211.00
211.00
211.00
352.00
434.00
434.00
434.00
926.00
926.00

...
...
...
...
...
...
...
...
...
...

...
...
...
...
...
...
...
...
...
...

...
...
...
...
...
...
...
...
...
...

QH215c
QH220c
QH225cf
QH230c

$195.00
195.00
195.00
195.00

...
...
...
...

...
...
...
...

QH315c
QH320c
QH325cf
QH330c

22,000 AIR
15
20
25
30
40
50
60
70
80
90
100
110
125
150
175
200

QO115VH cd
QO120VH cd
QO125VHc
QO130VHc
...
...
...
...
...
...
...
...
...
...
...
...

$42.30
42.30
48.50
48.50
...
...
...
...
...
...
...
...
...
...
...
...

42,000 AIR

Circuit Breaker Wire Sizesa
Wire Size (AWG)
Al
Cu
#14–8
#14–8
QO
.
.
.
(2)
#14–10
1-pole
#8–2
#8–2
#14–8
#14–8
...
(2) #14–10
#8–2
#8–2
QO
#4–2/0
#4–2/0
2-pole
#4–
150–200 300 kcmil 300#4–
kcmil
10–30
#14–8
#14–8
QO
35–70
#8–2
#8–2
3-pole
80–125
#4–2/0
#4–2/0
#4–
QOB-VH 110–150 300#4–
kcmil 300 kcmil
QOT
15–20
#12–8
#14–8
QO-AFI,
15–30
#12–8
#14–8
QO-GFI & 40, 50, 60 #12–4
#14–6
QO-EPD
QO-PL
10–60
#12–2
#14–2
Breaker
Type

Ampere
Rating
10–30
10–30
35–70
10–30
10–30
35–70
80–125

40
45
50
60
70
80
90
100
110
125

Pan Rail Slot

Circuit Limiting QOT Tandem Breakers
QOT tandem breakers have a mounting cam as
shown. Installation into a QO load center can only
be made in those positions having a mounting
pan rail slot. Meets Par. 408.15 of NEC®. UL
Listed as Class CTL.

...
...
...
...
...
...
...
...
...
...

...
...
...
...
...
...
...
...
...
...

65,000 AIR
15
20
25
30

QH115cd
QH120cd
QH125cf
QH130c

$78.00
78.00
78.00
78.00

$338.00
338.00
338.00
338.00

QOT Tandem Circuit Breakers—10,000 AIR
Ampere
Ratinga
15 & 15
15 & 20
20 & 20

1-pole Tandem
120/240 Vac
Catalog No.
Price
QOT1515c
$38.60
QOT1520c
38.60
QOT2020c
38.60

2-pole Tandem
120/240 Vac
Catalog No.

Price

Order two QOT1515 or QOT2020 circuit breakers and handle tie
Cat. No. QOTHT at $2.50 for common switching of center two poles.

Replacement Tandem Breakers
For Use in Old Style Non-Class CTL QO Load Centers—10,000 AIR
Ampere
Ratinga

Mounting Cam
Rail Bead

...
...
...
...
...
...
...
...
...
...

10
15 & 15
15 & 20
20 & 20
20 & 30
30 & 20
30 & 30

1-pole—120/240 Vac
1 Space Required
Catalog No.
Price
....
...
QO1515 c
$48.50
QO1520 c
48.50
QO2020 c
48.50
QO2030 c
48.50
QO3020 c
48.50
QO3030 c
48.50

Two Single-pole
Individual Trip 120/240 Vac
2 Spaces Required
Catalog No.
Price
Order Two QO1515 or
QO2020 circuit breakers
and handle tie Cat. # QOTHT
....
...
QO20303020 i
$89.00
....
...
....
...

a 10–30 A circuit breakers are suitable for use with 60°C or 75°C conductors. 35–125 A circuit breakers are suitable for use with 75°C conductors.
b UL Listed 5000 AIR on corner grounded Delta systems.
c UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use
with HACR type circuit breakers.
d UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.
e Requires four spaces (#1–300 kcmil Al/Cu). Not suitable for use in 3-phase panel. Use only in single phase panel rated 150 A or greater.
f Order only. Contact your nearest Square D/Schneider Electric sales office.
g UL Listed for use ahead of QO, QO-GFI, QO-EPD, QOT, and QO-PL 10,000 AIR circuit breakers to permit their application at 22,000 A fault level.
h 100 A maximum branch mounted opposite.
i Includes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT.

Additional Infmation
Accessories . . . . . . . . . . . .page 13
© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE2A

Discount
Schedule

3

LOAD CENTERS

10,000 AIR

QO® Circuit Breakers
Class 685, 690, 730, 912, 950

www.SquareD.com
For the most up-to-date information

Plug-On Circuit Breakers—UL Listed Amperes Interrupting Rating (AIR) In Amperes RMS Symmetrical

LOAD CENTERS

1-pole
QO-AFI

Three-wire
QO-SWN

Two-wire
QO-SWN

2-pole
QO-GFI

1-pole
QO-GFI

QO
1-pole
With Shunt Trip
QO-K Key
Operated

QO-HM

High magnetic trip circuit breakers are recommended for applications where high
initial inrush may occur and for individual dimmer applications.

Ampere
Rating
a
120 Vac—10,000 AIR
15
20

QO-AFI

QO-HID QO-HID Circuit Breakers

HID circuit breakers are for use on circuits feeding fluorescent and high intensity
discharge (HID) lighting systems such as mercury vapor, metal halide, or high
pressure sodium. These circuit breakers are physically interchangeable with QO
circuit breakers.

1-pole
Catalog No

Price

QO115HMcd
QO120HMcd

$20.40
20.40

Ampere
Rating
a

1-pole
120/240 Vac

15
20
25
30
40
50

10,000 AIR
1 Space Required
Catalog No.
Price
QO115HIDc
$25.40
QO120HIDc
25.40
QO125HID
25.40
QO130HID
25.40
QO140HID
25.40
QO150HID
25.40

QO Circuit Breakers with arc fault protection in accordance with UL1699.

Ampere
Rating
a
15
20

1-pole 120 Vac
10,000 AIR
1 Space Required
Catalog No.
Price
QO115AFId
$160.
QO120AFId
160.

1-pole 120 Vac
22,000 AIR
1 Space Required
Catalog No.
Price
QO115VHAFId
$331.
QO120VHAFId
331.

QO-K
QO-GFI

QWIK-GARD® circuit breakers provide overload and short circuit protection,
combined with Class A ground fault protection. Class A denotes a ground fault
circuit interrupter that will trip when a fault current to ground is 6 milliamperes or
more, for people protection. Do not connect to more than 250 feet of load conductor
for the total one-way run to prevent nuisance tripping.
QWIK-GARD Circuit Breakers
With Ground Fault Circuit Interrupter
1-pole
2-pole Common Trip
120 Vac
120/240 Vac
10,000 AIR
22,000 AIR
10,000 AIR
1 Space Required
1 Space Required
2 Spaces Required
Catalog No.
Price
Catalog No.
Price
Catalog No.
Price
QO115GFI
$155.
QO115VHGFI $321.
QO215GFI
$275.
QO120GFI
155.
QO120VHGFI
321.
QO220GFI
275.
QO125GFI
155.
QO125VHGFI
321.
QO225GFI
275.
QO130GFI
155.
QO130VHGFI
321.
QO230GFI
275.
....
...
....
...
QO240GFI
275.
....
...
....
...
QO250GFI
275.
....
...
....
...
QO260GFIb
275.

Ampere
Rating
a

15
20
25
30
40
50
60

QO-EPD QO-EPD circuit breakers provide overload and short circuit protection combined

with Class B ground fault protection. They are designed to provide ground fault
protection of equipment at a 30 milliampere level. They are not designed to protect
people from electrical shock.

Ampere
Rating
a

15
20
25
30
40
50
60

1-pole
120 Vac
10,000 AIR
1 Space Required
Catalog No.
Price
QO115EPD
$273.
QO120EPD
273.
QO125EPD
273.
QO130EPD
273.
....
...
....
...
....
...

2-pole Common Trip
120/240 Vac
10,000 AIR
2 Spaces Required
Catalog No.
Price
QO215EPD
$440.
QO220EPD
440.
QO225EPD
440.
QO230EPD
440.
QO240EPD
440.
QO250EPD
440.
QO260EPDb
440.

QO-SWN Switch Neutral Common Trip 2002 NEC® 514.11
Ampere
Rating
a
10
15
20
25
30
40
50

4

2 Wire 120 Vac
10,000 AIR
2 Spaces Required
Catalog No.
Price
QO210SWN
$63.
QO215SWN
63.
QO220SWN
63.
QO225SWN
63.
QO230SWN
63.
QO240SWN
63.
QO250SWN
63.

3 Wire 120/240 Vac
10,000 AIR
3 Spaces Required
Catalog No.
Price
QO310SWN
$95.
QO315SWN
95.
QO320SWN
95.
QO325SWN
95.
QO330SWN
95.
QO340SWN
95.
QO350SWN
95.

DE2A

2-pole Common Trip
120/240 Vac
10,000 AIR
2 Spaces Required
Catalog No.
Price
QO215HID
$58.00
QO220HID
58.00
QO225HID
58.00
QO230HID
58.00
QO240HID
58.00
QO250HID
58.00

3-pole Common Trip
240 Vac
10,000 AIR
3 Spaces Required
Catalog No.
Price
QO315HID
$200.00
QO320HID
200.00
QO325HID
200.00
QO330HID
200.00
....
...
....
...

Key operated QO circuit breakers are available in single-pole construction and can be
mounted in any single-pole space which will accept a standard QO. These circuit
breakers can be turned ON or OFF or to RESET with a special key (Catalog No.
QOK10) included with the circuit breaker. These circuit breakers are UL Listed and
available as shown in the table.
120 Vac—10,000 AIR (1 Space Required)
Ampere
Rating
a
10
15
20
25
30

Catalog No.

Price

QO110K
QO115K
QO120K
QO125K
QO130K

$109.
109.
109.
109.
109.

a 10–30 ampere breakers are suitable for use with 60°C or 75°C conductors. 35–60 ampere
circuit breakers are suitable for use with 75°C conductors.
b Suitable only for feeding 240 Vac and 208 Vac 2 wire loads. Does not contain load neutral
connection.
c UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting
loads.
d UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment
having motor group combinations and marked for use with HACR type circuit breakers.

Non-automatic (Standard) Miniature Switches
Miniature non-automatic switches have the same physical packaging as
miniature circuit breakers, but open only when the handle is switched to
the OFF position.
Non-automatic switches provide no overcurrent protection or short
circuit protection. They must not be used on systems that have an
available fault current greater than the values listed in the table.
Non-automatic switches are UL Listed per UL 1087 and are CSA
certified.
Non-automatic Miniature Switches, 240 Vac 10 kA
Ampere
Rating
60
100
60
100
125

Discount
Schedule

2-pole
Catalog No.
Price
QO200
$ 46.90
QO2000
133.00
QOU200
58.00
QOU2000
164.00
QOU20001
302.00

3-pole
Catalog No.
Price
QO300
$165.00
QO3000
244.00
QOU300
190.00
QOU3000
277.00
QOU30001
477.00

© 2004 Schneider Electric
All Rights Reserved
6/7/04

QO® Circuit Breaker Accessories
Class 1130

www.SquareD.com
For the most up-to-date information

Accessories for Use with QO Miniature Circuit Breakers
Catalog Number

Converts any two adjacent 120/240 Vac single-pole QO breakers to independent trip 2-pole . . . . . . . . . . . . . . . . . . . . . .
Converts any two adjacent 120/240 Vac single-pole side-by-side QOT breakers to independent trip 2-pole . . . . . . . . . .

QO1HT
QOTHT

Handle Clamp:

Clamp for holding QO single-pole handle in “ON’’ or “OFF’’ position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clamp for holding QO or Q1 either 1, 2 or 3-pole breaker handles in “ON’’ or “OFF’’ position . . . . . . . . . . . . . . . . . . . . . .

Handle Padlock Attachment:

For padlocking single-pole QO breaker in “ON’’ or “OFF’’ position
Loose attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fixed attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For padlocking single-pole QO circuit breaker in “OFF’’ position only, fixed attachment. . . . . . . . . . . . . . . . . . . . . . . . . . .
For padlocking single-pole side-by-side QOT breaker in “ON’’ or “OFF’’ position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For 2 and 3-pole QO and Q1 breakers which require padlocking in either “ON’’ or “OFF’’ position. (Not GFI)
Loose attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fixed attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For padlocking 2 and 3-pole QO circuit breakers in “OFF’’ position only, fixed attachment. . . . . . . . . . . . . . . . . . . . . . . .
For padlocking single-pole QO-GFI, QO-AFI and QO-EPD circuit breakers in “OFF’’ position only, fixed attachment. .
For padlocking 2-pole QO-GFI in either “ON’’ or “OFF’’ position, fixed attachment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For padlocking 2-pole QO-GFI and QO-EPD circuit breakers in “OFF’’ position only, fixed attachment. . . . . . . . . . . . . .

SUB-FEED LUGS

Price
$

Schedule

2.50
2.50

DE2E
DE2E

QO1LO
HLO1

2.50
6.60

DE2E
DE2E

QOHPL
QO1PA
QO1PAF
QOTHPA

6.30
7.10
29.00
7.40

DE2E
DE2E
DE2E
DE2E

QO1HPL
QO1PL
QO2PAF
QOGFI1PAF
GFI2PA
QOGFI2PAF

7.10
7.10
17.20
34.00
6.10
25.60

DE2E
DE2E
DE2E
DE2E
DE2A
DE2E

60 ampere 2-pole plug-on – 2 spaces required (#6–2 Al/Cu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
125 ampere 2-pole plug-on – 2 spaces required (#12–2/0 Al/Cu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
225 ampere 2-pole plug-on – 4 spaces required (#4–300 Al/Cu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
125 ampere 3-pole plug-on – 3 spaces required (#12–2/0 Al/Cu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

QO60SL
QO2125SL
QO2225SLa
QO3125SL

31.40
91.00
205.00
91.00

DE2A
DE2A
DE2A
DE3

MECHANICAL INTERLOCK
ATTACHMENT:

For interlocking the handles of two 2-pole or one 2-pole and one 1-pole QO and Q1 breakers mounted
side-by-side so that only one circuit breaker can be “ON’’ at a time (Not QOU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

QO2DTI

16.60

DE2E

With Retaining Kit:

QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit
breakers in dual power supply applications. Can be used with (2) 2-poles or (1) 2-pole and (1) 1-pole QO
circuit breakers in QO816L100 load centers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

QO2DTIM

42.00

DE2E

LOAD CENTERS

Description
HANDLE ATTACHMENTS
Handle Tie:

QO1LO
QO1PL

QO1PA

HLO1
QO1HT

QO2DTI
QO1HPL

QOTHPA

Factory-installed Accessories for Use with QO Miniature Circuit Breakers
Factory-installed electrical accessories take up an additional pole space on QO®, QO-GFI, QO-EPD and QO-SWN circuit breakers. All AC electrical
accessories shown below are rated for 50/60 Hz. Accessories are not available for QOB-VH (2-pole 150 A and 3-pole 110–150 A) circuit breakers or
QO molded case switches and the 125, 150 or 200 A QO circuit breakers. QO circuit breakers will accept only one accessory per circuit breaker.
Undervoltage trip is not available on miniature circuit breakers.
Accessory
SHUNT
TRIP

Description
Trips the circuit breaker from a
remote location by means of a trip
coil energized from a separate
circuit. A 120 Vac shunt trip will
operate at 55% or more of rated
voltage. All other shunt trips will
operate at 75% or more of rated
voltage.

Rated
Voltage
AC/DC
AC

12
24
120
208
240

Coil
List Price Accessory
Burden Suffix
Adder
60 VA
168 VA
72 VA

-1042
-1042

$126.

126.

228 VA
288 VA

-1021
-1021
-1021

AUXILIARY Monitors circuit breaker contact status
SWITCHES and provides a remote signal indicating
the circuit breaker contacts are OPEN
or CLOSED.

Application

Contact Max.
Comb. Voltage

Max.
Load

Price
Suffix List
Adder

1A
1B

AC 120
AC 120

5A
5A

-1200
-1201

$ 88.
88.

1A

AC 120

5A

-2100

88.

• Auxiliary switch terminals accept
(2) #14–#12 AWG Cu leads.
• Leads (EH): Yellow for “A’’, Blue for
“B’’, Striped common #18 AWG Cu.

Application
• For use with momentary or
maintained push button.
• Not available on QO-GFI,
QO-EPD.
• Shunt trip terminals accept (2)
#14–#12 AWG Cu.

Description

ALARM
Used with control circuits and is
SWITCHES actuated only when the circuit breaker
has tripped. Standard construction
includes a normally-open contact.

Application
• Leads: Alarm switch terminals accept
(2) #14–#12 AWG Cu leads.
a Not suitable for use in 3-phase panels. Use only in single phase panel rated 150 A or greater.

© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE2

Discount
Schedule

5

QO® Load Centers
Series Rating
Class 1100

www.SquareD.com
For the most up-to-date information

The rating of the load center is equal to the lowest interrupting rating of any circuit breaker installed or combination series connected circuit breaker.
Additional or replacement circuit breakers MUST have an interrupting and voltage rating equal to or greater than that of the circuit breaker with the lowest
interrupting and voltage rating presently installed. See load center interior for circuit breaker types.
Short Circuit Current Rating
Maximum Short Circuit
Current Rating
(RMS Symmetrical)

Load Center Voltage Rating
240 Vac Max.
Systems Voltage

LOAD CENTERS

5,000

10,000

22,000

42,000

65,000

Integral or Remote
Square D Circuit Breaker or Remote Fuses
Fuse Class

Catalog
Designation
d

Current
Rating
Amperes
Max.

Square D Branch Circuit Breaker
Catalog
Designation
de

Current Rating Amperes
1-pole

240 Vac, 3 Phase 3 Wire Grounded "B" phase.

…

…

…

QO-H

…

120/240 Vac, 1 Phase 3 Wire

…

…

…

QO
QOT

10–70
15–30

2-pole

3-pole

15–100

…

10–200c
…

…
…

208Y/120 Vac, 3 Phase 4 Wire

…

…

…

QO

10–70

10–125c

10–100

240/120 Vac, 3 Phase 4 Wire Delta a

…

…

…

QO-H
QO

…
10–70

15–100
10–125c

…
10–100

240 Vac, 3 Phase 3 wire Delta

…

…

…

QO-H
QO

…
…

15–100
…

…
10–100

120/240 Vac, 1 Phase 3 Wire

…

…

…

QO-VH

15–30

15–200c

…

208Y/120 Vac, 3 Phase 4 Wire

…

…

…

QO-VH

15–30

15–125c

15–100

15–125c

15–100

240/120 Vac, 3 Phase 4 Wire Delta b

…

…

…

QO-VH

15–30

240 Vac, 3 Phase 3 wire Delta

…

…

…

QO-VH

…

120/240 Vac, 1 Phase 3 Wire

…

…

…

QOH

…

40–125c

…

208Y/120 Vac, 3 Phase 4 Wire

…

…

…

QOH

…

40–125c

…

120/240 V ac, 1 Phase 3 Wire

…

…

…

QH

15–30

15–30

…

208Y/120 Vac, 3 Phase 4 Wire

…

…

…

QH

15–30

15–30

15–30

240/120 Vac, 3 Phase 4 Wire Delta b

…

…

…

QH

15–30

15–30

15–30

240 Vac, 3 Phase 3 wire Delta

…

…

…

QH

…

…

15–30

120/240 Vac, 1 Phase 3 Wire

…

QOM-VH

225

QO
QOT

15–70
15–30

15–200c
…

…
…

120/240 Vac, 1 Phase 3 Wire

…

QO-VH

200

QO
QOT

15–70
15–30

15–200c
…

…
…

…

10–100

Series Combination Short Circuit Current Rating

22,000

25,000

42,000

65,000

100,000

208Y/120 Vac, 3 Phase 4 Wire

…

QO-VH

100

QO

15–70

15–100

15–100

240/120 Vac, 3 Phase 4 Wire Delta b

…

QO-VH

100

QO

15–70

15–100

15–100

240 Vac, 3 Phase 3 wire Delta

…

QO-VH

100

QO

…

…

15–100

120/240 Vac, 1 Phase 3 Wire

…

QD

225

QO
QOT

15–70
15–30

15–200c
…

…
…

208Y/120 Vac, 3 Phase 4 Wire

…

QD

225

QO
QO-VH

15–70
15–30

15–125c
15–125c

15–30
15–100

240/120 Vac, 3 Phase 4 Wire Delta a

…

QD

225

QO-H
QO
QO-VH

…
15–70
15–30

15–100
15–125c
15–125c

…
15–30
15–100

240 Vac, 3 Phase 3 wire Delta

…

QD

225

QO-H
QO
QO-VH

…
…
…

15–100
…
…

…
15–30
15–100

120/240 Vac, 1 Phase 3 Wire

…

QOH

125

QO
QOT

15–70
15–30

15–100
…

…
…

120/240 Vac, 1 Phase 3 Wire

…

QG

225

QO
QOT

15–70
15–30

15–200c
…

…
…

208Y/120 Vac, 3 Phase 4 Wire

…

QG

225

QO
QO-VH

15–70
15–30

15–125c
15–125c

15–30
15–100

240/120 Vac, 3 Phase 4 Wire Delta a

…

QG

225

QO-H
QO
QO-VH

…
15–70
15–30

15–100
15–125c
15–125c

…
15–30
15–100

240 Vac, 3 Phase 3 wire Delta

…

QG

225

QO-H
QO
QO-VH

…
…
…

15–100
…
…

…
15–30
15–100

120/240 Vac, 1 Phase 3 Wire

…
…

QJ

225

QO
QOT

15–70
15–30

15–200c

208Y/120 Vac, 3 Phase 4 Wire

…
…

QJ

225

QO
QO-VH

15–70
15–30

15–125c
15–125c

15–30
15–100

120/240 Vac, 1 Phase 3 Wire

T3

…

200

QO
QOT

15–70
15–30

15–200c
…

…
…

208Y/120 Vac, 3 Phase 4 Wire

T3

…

200

QO

15–70

15–125c

15–100

240/120 Vac, 3 Phase 4 Wire Delta b

T3

…

200

QO

15–70

15–125c

15–100

240 Vac, 3 Phase 3 wire Delta

T3

…

200

QO

…

…

15–100

a 240 Vac 3 Phase 4 Wire Delta: When wired for Delta system, phase "B" must be 208 V to neutral. Two-pole circuit breakers connected to phase "B" must be rated 240 V (QO-H). Single-pole circuit
breakers must not be connected to phase "B".
b 240 Vac 3 Phase 4 Wire Delta: When wired for Delta system, phase "B" must be 208 V to neutral. For this Short Circuit Current Rating, single-pole and two-pole circuit breakers must not be connected
to phase "B".
c 100 amperes maximum branch circuit breaker in load centers with 125 A maximum mains rating.
d See circuit breaker for voltage and interrupting rating.
e QO includes suffixes: GFI, EPD, PL, AS and AFI. QO-VH includes suffixes GFI and AFI

6

© 2004 Schneider Electric
All Rights Reserved
6/7/04

QO® Load Centers
Indoor—Single Phase, Main Lug
Class 736, 1130

www.SquareD.com
For the most up-to-date information

Single Phase Three Wire—120/240 Vac—UL Listed
Main Lugs (Order QO, QOT, QO-EPD, QO-GFI and QO-PL branch circuit breakers from pages 3 and 4)
Mains
Rating Spaces
(A)

Max.
Max.
Total
Number
Number
Price
Single
of Tandem (Interior,
Pole
Circuit
Box &
Circuitsa Breakers Cover)

Indoor Cover with Door
(Order Separately)

Load Center
Box and Interior
Catalog Number

Flush
Surface
Catalog No. Catalog No.

Price

Main
Wire Size
AWG/kcmil

Price

Al

Cu

Equipment
Ground Bar Kit
(Order Separately)
Catalog No.

Price

Box No.
See
Page
19

$ 7.60

1

7.20

2

30

2

2

0

70

2

4

2

6

12

6

100

100
125

$ 27.80 QO2L30Scd

$ 27.80

#12–10 #14–10 PK3GTA-1

45.70 QO24L70F/Sef

45.70

Cover Included—Without Door

58.00 QO612L100F/Se g

58.00

60.00 QO612L100DF/Segh

60.00

Cover Included—With Door

87.00 QO816L100F/Seg

87.00

Cover Included—Without Door

8

16

8

95.00 QO816L100DF/Segh

95.00

Cover Included—With Door

6

12

6

74.00 QO612L100DFCU/SCUeghi

74.00

Cover Included—With Door

8

16

8

116.00 QO816L100DFCU/SCUeghi

116.00

Cover Included—With Door

4

8

4

62.00 QO148L125GF/Sej

62.00

Cover Included—Without Door

#12–3

#14–4 PK4GTA

#8–1

PK7GTA

7.80

4

#8–1

PK7GTA

7.80

4

#8–1

PK7GTA

7.80

4

#8–1

PK7GTA

7.80

4

#8–1

PK7GTA

7.80

#12–2/0 #14–2/0 PK7GTAm

LOAD CENTERS

Fixed Mains—Factory-installed Main Lugs—10,000 RMS Sym. Amperes Short Circuit Current Ratingb

4
21

Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratingb k
QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus

I
N
D
O
O
R

125

12
12

12
24

0
12

$ 131.10 QO112L125G
157.10 QO11224L125G

$106.00
132.00

QOC16UF
QOC16UF

QOC16US $ 25.10
QOC16US
25.10

PK9GTAm
PK15GTAm

6
6

16
16

16
24

0
8

170.10 QO116L125G
200.10 QO11624L125G

145.00
175.00

QOC24UF
QOC24UF

QOC24US
QOC24US

25.10
25.10

PK12GTAm
PK15GTAm

7
7

20
20
24
32

20
24
24
32

0
4
0
0

181.10
247.10
254.10
289.40

156.00
222.00
229.00
263.00

QOC24UF
QOC24UF
QOC24UF
QOC32UF

QOC24US
QOC24US
QOC24US
Use Flush

25.10
25.10
25.10
26.40

PK15GTAm
PK15GTAm
PK15GTAm
PK23GTA & LK100ANm

7
7
7
8

QO120L125G
QO12024L125G
QO124L125G
QO132L125G

#6–2/0

Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratingbk
QOM2 Main Frame Size—Convertible To Main Circuit Breaker—Copper Bus
150

20
24
30

30
24
30

10
0
0

200

12
24
30
30
40

12
36
30
40
40

0
12
0
10
0

225

42

42

0

$ 279.00 QO12030L150G
287.00 QO124L150G
291.00 QO130L150G
235.00
546.00
316.00
369.00
497.00

QO112L200G
QO12436L200TFTl
QO130L200G
QO13040L200G
QO140L200G

552.00 QO142L225G

$221.00
229.00
233.00

QOC30UF
QOC30UF
QOC30UF

QOC30US $ 58.00
QOC30US
58.00
QOC30US
58.00

#6–250

PK23GTA & LK100ANm
PK15GTAm
PK23GTA & LK100ANm

9
9
9

177.00
488.00
271.00
311.00
439.00

QOC30UF
QOC40UF
QOC30UF
QOC30UF
QOC40UF

QOC30US
QOC40US
QOC30US
QOC30US
QOC40US

58.00
58.00
58.00
58.00
58.00

#6–250

PK15GTAm
PK23GTA & LK100ANm
PK23GTA & LK100ANm
PK23GTA & LK100ANm
PK23GTA & LK100ANm

9
10
9
9
10

478.00

QOC42UF

QOC42US

74.00

#6–300

PK23GTA & LK100ANm

11

Fixed Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratingbk
400

12

12

0

$1468.00 QON12LS400(Int)n
MH50 (Box)

1050.00 MHC50QVF MHC50QVS
75.v
1125.00 MHC53QVF MHC53QVS
75.v

400

30

30

0

QON30LS400(Int) n
1547.00 MH50
(Box)

400

42

42

0

QON42LS400(Int) n
1641.00 MH53
(Box)

$ 971.00 MHC50QVF MHC50QVS $422.v
75.v

Above listings thru 200 A mains rating meet Federal Specification W-P-115c as
Type 1, Class 2.
a Maximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers.
b UL short circuit current rating depends on lowest interrupting rating of circuit breaker
installed.
c Will not accept QO-EPD or QWIK-GARD® QO-GFI circuit breakers.
d Mains rated 25 A when Al wire is used.
e Order F for flush device or S for surface device.
f Use #10 maximum size wire for GFI circuit breaker.
g 70 A Max. branch circuit breaker and 70 A max. back fed main circuit breaker.
h No provisions for lock kits.
i CU indicates copper bus.
j Copper bus.
k UL Listed 5000 A short circuit current rating for corner grounded Delta systems.
Use QO-H circuit breakers only.
l Supplied with feed-thru lugs.
m Factory-included.
n Interior only, order box separately.
o PK27GTA includes a #6–2/0 Al/Cu lug.

QO816L100F or S
without cover

DE3A

PK27GTAo

422.v

(1) #1/0–750
or (2) #1/0–300

or

441.v

(1) #1/0–750
or (2) #1/0–300

PK15GTA-6

$22.50

15

35.50

17

15

Main Circuit Breaker Kits

QOM1 Frame Size
50–125 Amperes

QOM2 Frame Size
100–225 Amperes

Field-installable Main Circuit Breaker (Convertible Load Centers Only)
p
Main Circuit
Breaker
Rating (A)

Use With
Convertible
Load Center
Mains Rating

22,000 AIR q
Main Circuit
Breaker

Price

Lug Wire Sizer
AWG/kcmil
Al or Cu

QOM1 Frame Size
50
60
70
80
90
100
110
125

100–125
100–125
100–125
100–125
100–125
100–125
125
125

QOM50VH
QOM60VH
QOM70VH
QOM80VH
QOM90VH
QOM100VH
QOM110VH
QOM125VH

$ 93.00
93.00
93.00
134.00
134.00
134.00
312.00
312.00

#12–2/0

QOM2 Frame Sizes
100
125
150
175
200
225

150–225
150–225
150–225
200–225
200–225
225

QOM2100VH
QOM2125VH
QOM2150VH
QOM2175VH
QOM2200VH
QOM2225VH

312.00
312.00
312.00
312.00
312.00
312.00

#4–300

p Do not exceed the load center mains rating.
q 22,000 AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10,000 AIR
branch circuit breakers to permit their application on systems with up to 22,000 amperes
available fault current.
r Wire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find
out maximum wire size permitted in a particular load center per UL, see pages 7 thru 12 under
Main Wire Size.
s Add suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126.00.

QO120L125G

For additional information, reference Catalog #1100CT9901.
© 2004 Schneider Electric
All Rights Reserved
6/7/04

(1) #1/0–750
or (2) #1/0–300

v PE1A

Discount
Schedule

7

QO® Load Centers
Indoor—Single Phase, Main Circuit Breaker
Class 1130

www.SquareD.com
For the most up-to-date information

Single Phase Three Wire—120/240 Vac—UL Listed
Main Circuit Breaker (Order QO, QOT, QO-EPD, QO-GFI, QO-AFI and QO-PL branch circuit breakers from pages 3 and 4.)
aMax.
Max.
Mains
Number Number Total Price
Rating Spaces Single of Tandem (Interior,
Box &
(A)
Pole
Circuit
Cover)
Circuits Breakers

Indoor Cover with Door
(Order Separately)

Load Center
Box and Interior
Catalog Number

Price

Flush
Catalog No.

Surface
Catalog No.

Price

Main
Wire Size
AWG/kcmil
Al or Cu

Equipment
Ground Bar Kit
(Order Separately)
Catalog No.

Price

Box No.
See
Page
19

#6–1

PK9GTA
PK12GTA
PK15GTA

$ 8.90
10.50
11.40

5
6
6

LOAD CENTERS

Convertible Mains —Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
—Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 7) b
QOM1 Main Circuit Breaker Frame Size—Copper Bus

100

125

I
N
D
O
O
R

12
16
20

12
16
20

0
0
0

$ 226.10
253.10
289.10

QO112M100
QO116M100
QO120M100

$ 201.
228.
264.

QOC12UF
QOC20U100F
QOC20U100F

QOC12US
QOC20U100S
QOC20U100S

24
32

24
32

0
0

369.10
484.10

QO124M100
QO132M100

24
32

24
32

0
0

546.10
694.40

QO124M125
QO132M125

$ 25.10
25.10
25.10

344.
459.

QOC24UF
QOC32UF

QOC24US
Use Flush

25.10
25.10

#6–2/0

PK15GTA
PK18GTA

11.40
12.50

7
8

521.
668.

QOC24UF
QOC32UF

QOC24US
Use Flush

25.10
26.40

#6–2/0

PK15GTA
PK18GTA

11.40
12.50

7
8

#4–250

PK18GTA
PK15GTA
PK18GTA
PK18GTA

$12.50
11.40
12.50
12.50

9
9
9
10

PK23GTA
PK15GTA
PK18GTA
PK23GTA
PK23GTA
PK23GTA

14.20
11.40
12.50
14.20
14.20
14.20

9
9
9
9
10
11

PK23GTA
PK23GTA

14.20
14.20

11
11

$22.50

16

35.50

16

Convertible Mains —Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
—Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 7)b
QOM2 Main Circuit Breaker Frame Size—Copper Bus
150

20
24
30
32

30
24
30
32

10
0
0
0

$ 547.00
566.00
569.00
646.00

QO12030M150
QO124M150
QO130M150
QO132M150

$ 489.
508.
511.
588.

QOC30UF
QOC30UF
QOC30UF
QOC40UF

QOC30US
QOC30US
QOC30US
QOC40US

$ 58.00
58.00
58.00
58.00

200

20
24
30
30
40
42

40
24
30
40
40
42

20
0
0
10
0
0

547.00
577.00
586.00
638.00
747.00
813.00

QO12040M200
QO124M200
QO130M200
QO13040M200
QO140M200
QO142M200

489.
519.
528.
580.
689.
739.

QOC30UF
QOC30UF
QOC30UF
QOC30UF
QOC40UF
QOC42UF

QOC30US
QOC30US
QOC30US
QOC30US
QOC40US
QOC42US

58.00
58.00
58.00
58.00
58.00
74.00

225

40
42

40
42

0
0

797.00
835.00

QO140M225
QO142M225

723.
761.

QOC42UF
QOC42UF

QOC42US
QOC42US

74.00
74.00

#4–250

#4–300

Fixed Mains—Factory-installed LAL Main Circuit Breaker—42,000 Fully Rated RMS Sym. Amperes Maximum Short Circuit Current Ratingc
300

42

400

42

42
42

0
0

$4686.00

QON42MS300(Int)d
MH68 (Box)

$4107.
75.r

4686.00

QON42MS400(Int)d
MH68 (Box)

4107.
75.r

MHC68VF
MHC68VF

MHC68VS
MHC68VS

$504.r

(1) #4–500
or (2) #4–3/0

#4–600
504.r or(1)
(2) #4–250

PK27GTAe
or
PK15GTA-6

Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a Maximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers.
b 22,000 AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10,000 AIR
branch circuit breakers to permit their application on systems with up to 22,000 amperes available
fault current.
c UL short circuit current rating depends on lowest interrupting rating of circuit breakers
installed. Also, UL Listed 5000 A short circuit current for corner grounded Delta systems.
Use QO-H circuit breakers only.
d Interior only, order box separately.
e PK27GTA includes a #6–2/0 Al/Cu lug.

Main Lug Kits

QOL125

QOL225

Field-installable Main Lugs (Convertible Load Centers Only)
Main Lug f
Ampere Rating

Use On
Convertible
Load Center
With Mains Rating

Catalog
Number

Price

125

100–125

QOL125h

$29.40

#6–2/0

225

150–225

QOL225h

69.00

#6–300

Lug Wire Size g
AWG/kcmil
Al or Cu

f Do not exceed the load center mains rating.
g Wire range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size
permitted in a particular load center per UL, see pages 7 thru 12 under main wire size.
h If main circuit breaker knockout has been removed from the load center’s trim, order
appropriate filler plate from page 14.

QO130M150

For additional information, reference Catalog #1100CT9901.

8

DE3A

rPE1A

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

QO® Load Centers
Rainproof—Single Phase, Main Lugs, Main Circuit Breaker
Class 1130

www.SquareD.com
For the most up-to-date information

Single Phase Three Wire—120/240 Vac—UL Listed
Main Lugs (Order QO, QOT, QO-GFI, QO-EPD, QO-AFI and QO-PL branch circuit breakers from pages 3 and 4.)
Mains
Rating
(A)

Max. Number
Single
Pole
Circuitsa

Spaces

Max.
Number
of Tandem
Circuit
Breakers

Total Price
(Interior,
Box and
Cover)

Main
Wire Size
AWG/kcmil

Load Center
Box and Interior
Catalog Number

Price

Equipment
Ground Bar Kit
(Order Separately)
Catalog No.

Price

Box No.
See
page 20

Al

Cu

#14–4

#14–4

$ 75.00

#12–6

#14–6

PK3GTA-1

$ 7.60

1R

87.00

#12–3

#14–4

PK4GTA

7.20

1R

Non-Metallic Enclosure
Fixed Mains—Factory-installed Main Lugs—10,000 RMS Sym. Amperes Short Circuit Current Rating
60

2

4

2

$ 68.00

QO24L60NRNM

$ 68.00

Factory-incl.

1NM

LOAD CENTERS

Metallic Enclosure
Fixed Mains—Factory-installed Main Lugs—10,000 RMS Sym. Amperes Short Circuit Current Rating

R
A
I
N
P
R
O
O
F

40

2

2

0

$ 75.00

70

2

4

2

87.00

QO2L40RBb

100

6
6
8

12
12
16

6
6
8

95.00
105.00
154.00

QO612L100RBc
QO612L100TRBc
QO816L100RBc

95.00
105.00
154.00

#8–1

PK7GTA
Factory-installed
PK7GTA

7.80
...
7.80

2R
2R
2R

100

6
8

12
16

6
8

116.00
186.00

QO612L100RBCUcd
QO816L100RBCUcd

116.00
186.00

#8–1

PK7GTA
PK7GTA

7.80
7.80

2R
2R

125

4

8

4

101.00

QO148L125GRBd

101.00

QO24L70RBb

#12–2/0

#14–2/0

PK7GTA Factory-incl.

15R

Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Maximum Short Circuit Currente f g
QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus
125

12
12
16
24

12
24
24
24

0
12
8
0

$190.00
243.00
290.00
348.00

QO112L125GRB
QO11224L125GRB
QO11624L125GRB
QO124L125GRB

$190.00
243.00
290.00
348.00

#6–2/0

PK9GTA Factory-incl.
PK15GTA Factory-incl.
PK15GTA Factory-incl.
PK15GTA Factory-incl.

3R
3R
4R
4R

Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Maximum Short Circuit Current e f g
QOM2 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus
150

30

30

0

$391.00

#6–250

PK23GTA & LK100AN Factory-incl.

6R

200

12
30
30
40

12
30
40
40

0
0
10
0

320.00
444.00
476.00
647.00

QO130L150GRB
QO112L200GRB
QO130L200GRB
QO13040L200GRB
QO140L200GRB

$391.00
320.00
444.00
476.00
647.00

#6–250

PK9GTA Factory-incl.
PK23GTA & LK100AN Factory-incl.
PK23GTA & LK100AN Factory-incl.
PK23GTA & LK100AN Factory-incl.

5R
6R
6R
7R

225

42

42

0

873.00

QO142L225GRB

873.00

#6–300

PK23GTA & LK100AN Factory-incl.

8R

Single Phase Three Wire—120/240 Vac—UL Listed
Main Circuit Breaker Order QO, QOT, QO-GFI, QO-EPD and QO-PL branch circuit breakers from pages 3 and 4.
Mains
Rating
(A)

Spaces

a Max.
Number
Single
Pole
Circuits

Max.
Number
of Tandem
Circuit
Breakers

Total Price
(Interior,
Box and
Cover)

Load Center
Box and Interior
Catalog Number

Price

Main
Wire Size
AWG/kcmil
Al or Cu

Equipment
Ground Bar Kit
(Order Separately)
Catalog No.

Price

Box No.
See
page 20

Convertible Mains —Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
—Convertible to Main Lugs (see page 8) or Lower Amperage Main Circuit Breaker (see page 7)hg
QOM1 Main Circuit Breaker Frame Size—Copper Bus

R
A
I
N
P
R
O
O
F

100

12
16
20

12
16
20

0
0
0

$307.
336.
368.

QO112M100RB
QO116M100RB
QO120M100RB

$307.
336.
368.

#6–2/0

PK9GTA
PK12GTA
PK15GTA

$ 8.90
10.50
11.40

3R
4R
4R

125

24

24

0

636.

QO124M125RB

636.

#6–2/0

PK15GTA

11.40

4R

Convertible Mains —Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
—Convertible to Main Lugs (see page 8) or Lower Amperage Main Circuit Breaker (see page 7)hg
QOM2 Main Circuit Breaker Frame Size—Copper Bus
150

20
30

30
30

10
0

$635.
748.

QO12030M150RB
QO130M150RB

$635.
748.

#4–250

PK18GTA
PK18GTA

$12.50
12.50

5R
6R

200

20
30
40

40
30
40

20
0
0

636.
769.
931.

QO12040M200RB
QO130M200RB
QO140M200RB

636.
769.
931.

#4–250

PK23GTA
PK18GTA
PK23GTA

14.20
12.50
14.20

5R
6R
7R

Feed Thru
Main Circuit Breaker With Feed-Thru Lugs—Copper Bus—22,000 RMS Sym. Amperes Short Circuit Current Ratingh
125

6

12

6

$413.

QO1612M125FTRB

$413.

#4–2/0

PK12GTA

$10.50

3R

150

8

16

8

575.

QO1816M150FTRB

575.

#4–250

PK15GTA-L

23.30

6R

200

8

16

8

575.

QO1816M200FTRB

575.

#4–250

PK15GTA-L

23.30

6R

Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a Maximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers.
b Use #10 maximum size wire for GFI circuit breaker.
c 70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker.
d Copper bus.
e UL short circuit current rating depends on lowest interrupting rating of circuit breakers installed.
f UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
g Side hinge door device; allow 11⁄4" on left side for door to open.
h 22,000 AIR main circuit breaker UL Listed for use ahead of QO, QOT, QO-GFI, QO-EPD and QOPL 10,000 AIR branch circuit breakers to permit their application on systems up to 22,000 A available
fault current.

For additional information, reference Catalog #1100CT9901.

© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE3A

Discount
Schedule

9

QO® Load Centers
Three Phase—Main Lugs, Main Circuit Breaker
Class 1130
Three Phase
Mains
Rating
(A)

www.SquareD.com
For the most up-to-date information

(Order QO, QO-GFI, QO-AFI, QO-PL branch circuit breakers from pages 3 and 4.)
3 Phase 4 Wire 208Y/120 Vac, 3 Phase 4 Wire 240/120 Vac Delta and 3 Phase 3 Wire 240 Vac Delta—UL Listed.

Max.
Number
of 1-pole
QO
Breakers

Total Price
(Interior,
Box and
Cover)

Indoor Cover with Door
(Order Separately)

Load Center
Box and Interior
Catalog Number

Price

Flush
Catalog No.

Surface
Catalog No.

Main
Wire Size
AWG/kcmil
Price

Al

Equipment
Ground Bar Kit
(Order Separately)
Cu

Catalog No.

Priceu

Box No.
See
Pages
19, 20

LOAD CENTERS

Fixed Mains—Factory-installed Main Lugs—Copper Bus—65,000 RMS Symmetrical Amperes Short Circuit Current Rating a
60

3

125

12
20
24

$

246.10
339.10
385.10

71.00

QO403L60NF/S
QO312L125G
QO320L125G
QO324L125G

$

221.00
314.00
360.00

71.00

QOC16UF
QOC24UF
QOC24UF

Cover Included With Load Center
QOC16US
QOC24US
QOC24US

$ 25.10 u
25.10 u
25.10 u

...

200

18

353.00

QO318L200G

295.00

QOC30UF

QOC30US

58.00 u

#10–6

PK4GTA

$ 7.20

13

#6–2/0

#6–2/0

Factory-incl.g
Factory-incl.g
Factory-incl.g

...
...
...

6
7
7

#6–250

#6–250

Factory-incl.f

...

9
9

30
471.00 QO330L200G
413.00
QOC30UF
QOC30US
58.00 u
Factory-incl.f
...
I
225
42
635.00 QO342L225G
561.00
QOC42UF
QOC42US
74.00 u
#6–300
#6–300
Factory-incl.f
...
N
D
O Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25,000 RMS Symmetrical Amperes Maximum
O Short Circuit Current Rating b
100
27
$ 705.00 QO327M100 c
$ 647.00
QOC30UF
QOC30US
$ 58.00 u
#4–2/0
#4–2/0
PK15GTA
$11.40
R

11

9

125

30

1287.00

QO330MQ125 d

1226.00

QOC342MQF

QOC342MQS

61.00

#4–300

#4–300

PK18GTA

12.50

12

150

30
42

1287.00
1412.00

QO330MQ150d
QO342MQ150d

1226.00
1351.00

QOC342MQF
QOC342MQF

QOC342MQS
QOC342MQS

61.00
61.00

#4–300

#4–300

PK18GTA
PK23GTA

12.50
14.20

12
12

200

30
42

1287.00
1412.00

QO330MQ200d
QO342MQ200d

1226.00
1351.00

QOC342MQF
QOC342MQF

QOC342MQS
QOC342MQS

61.00
61.00

#4–300

#4–300

PK18GTA
PK23GTA

12.50
14.20

12
12

225

42

1412.00

QO342MQ225d

1351.00

QOC342MQF

QOC342MQS

61.00

#4–300

#4–300

PK23GTA

14.20

12

Fixed Mains—Factory-installed Main Lugs—Copper Bus—65,000 RMS Symmetrical Amperes Short Circuit Current Rating a e
60

3

$ 118.00

125

12
20

323.00
419.00

QO403L60NRB
QO312L125GRB
QO320L125GRB

$ 118.00
323.00
419.00

...

#10–6

PK4GTA

#6–2/0

#6–2/0

Factory Incl.g
Factory Incl.g

$ 7.20

10R

...
...

3R
4R

Cover Included
R
18
412.00 QO318L200GRB
412.00
Factory Incl.f
...
200
#6–250
#6–250
A
30
559.00 QO330L200GRB
559.00
Factory Incl.f
...
I
225
42
996.00 QO342L225GRB
996.00
#6–300
#6–300
Factory Incl.f
...
N
P Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25,000 RMS Symmetrical Amperes Maximum
R Short Circuit Current Rating be
O
100
27
$ 790.00 QO327M100RB c
$ 790.00
#4–2/0
#4–2/0
PK15GTA
$11.40
O
125
30
1431.00
QO330MQ125RB
d
1431.00
#4–300
#4–300
PK18GTA
12.50
F
150

30

1431.00 QO330MQ150RBd

1431.00

200

30
42

1431.00 QO330MQ200RB d
1555.00 QO342MQ200RBd

1431.00
1555.00

225

42

1555.00 QO342MQ225RBd

1555.00

Cover Included

#4–300

6R
6R
8R

6R
14R

#4–300

PK18GTA

12.50

14R

#4–300

#4–300

PK18GTA
PK23GTA

12.50
14.20

14R
14R

#4–300

#4–300

PK23GTA

14.20

14R

Above listings thru 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
a UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
b 25,000 RMS symmetrical amperes short circuit current rating maximum with Square D Type QDL main circuit breaker, or 22,000 RMS symmetrical amperes SCCR maximum
with back-fed Type QO-VH main circuit breaker, feeding QO 10,000 AIR branch circuit breakers.
c Includes factory-installed back fed QO3100VH main circuit breaker.
d 65,000 RMS Symmetrical Amperes Short Circuit Current Rating maximum with field-installed Square D
type QGL 65,000 AIR minimum main circuit breaker feeding QO and Q1 10,000 AIR minimum branch circuit breakers.
e Side hinge door device allow 11⁄4" on left side for door to open.
f PK23GTA and LK100AN.
g PK15GTA.

Three Phase Main Circuit Breakers
Field-installable alternate main circuit breakers for QO three phase main circuit breaker load
centers rated 70–225 A. Do not exceed the load center main rating.
Amperage
70
80
90
100
110
125
150
175
200
225
Price

25k AIR
QDL32070
QDL32080
QDL32090
QDL32100
QDL32110
QDL32125
QDL32150
QDL32175
QDL32200
QDL32225
$1189.00s

65k AIR
QGL32070
QGL32080
QGL32090
QGL32100
QGL32110
QGL32125
QGL32150
QGL32175
QGL32200
QGL32225
$1628.00s

100k AIRh
QJL32070
QJL32080
QJL32090
QJL32100
QJL32110
QJL32125
QJL32150
QJL32175
QJL32200
QJL32225
$1864.00s

h When these 3-pole circuit breakers are used as the main circuit breaker of a three-phase load
center, the maximum AIR rating is 65,000 at 240 Vac and 100,000 at 208 Vac.

Three Phase Main Lug Kits
Field-installable main lugs for convertible three phase main circuit breaker load centers.
Main Lug
Amperage Rating
125
225

Catalog Number

Price

QOL3125
QOL3225

$ 44.90
105.00

Lug Wire Size
AWG/kcmil
#6–2/0 Cu/Al
#6–300 Cu/Al

QO342MQ200

QO312L125G

For additional information, reference Catalog #1100CT9901.

10

DE3

uDE3A

sDE2

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

QO® Load Centers
Special Applications
Class 1130

www.SquareD.com
For the most up-to-date information

Order QO, QOT, QO-EPD, QO-GFI and QO-AFI Branch Circuit Breakers from pages 3 and 4.
Spaces

Max.
Number
Single
Pole
Circuitsa

Manufactured Housing
30 c
50

2
2

Max.
Number
of Tandem
Circuit
Breakers

Equipment
Ground Bar Kit
(Order Separately)

Load Centerb
Box , Interior, and Cover
Catalog Number

Price

1 Phase—2 Wire 120 Vac—Main Lugs Only—CSA Certified
10,000 RMS Sym. Ampere Short Circuit Current Rating
2
0
QO2L30TTSd
4
2
QO24L50TTSe

$

Catalog No.

33.90
52.00

Price

Factory-installed

Main
Wire Size
AWG/kcmil
Al

Cu

#12–10
...

#14–10
#14–6

1 Phase—2 Wire 120 Vac—Main Circuit Breaker—CSA Certified—10,000 RMS Sym. Ampere Short Circuit Current Rating
30
3
5
2
QO35FM30TTF/S
$ 55.00
Factory-installed
1 Phase—3 Wire 120/240 Vac—Main Lugs Only—CSA Certified—10,000 RMS Sym. Ampere Short Circuit Current Rating
70
2
4
2
QO24L70TSe
$ 52.00
6
12
6
QO612L100TF/Sg
57.00
Factory
6
12
6
QO612L100DTF/Sg
67.00
Installed
100
8
16
8
QO816L100TF/Sg
91.00
8
16
8
QO816L100DTF/Sg
106.00

Generator Panel
30
60

4
4

1
2

f

3

#12–3

#14–4

2
4
4
4
4

#14–8
#8–2

4
4

#4–1

1 Phase—3 Wire 120/240 Vac—Factory-installed Main Circuit Breakers with Mechanical Interlock
10,000 RMS Sym. Amperes Short Circuit Current Rating
8
4
QO48M30DSGP
$375.00
PK7GTA
8
4
QO48M60DSGP
375.00
PK7GTA

Phase—3 Wire 120/240 Vac—UL Listed
I Load Center with Cover 1Complete
QO Load Center—Box, Interior & Combination Cover—in One Package
N
Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratinghi
D Convertible
QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 7)—Copper Bus
O
12
12
0
QO112L125GC
$125.00
O
12
12
QO11224L125GC
166.00
125 A
24
R
20
0
QO120L125GC
189.00
20

Box No.
See
page 19

$7.80
7.80

PK12GTA Incl.
PK15GTA Incl.
PK15GTA Incl.

#14–8
#8–2

#6–2/0
#6–2/0
#6–2/0

6
6
7

Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratinghi
QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 7)—Copper Bus
150 A
30
30
0
QO130L150TC
$301.00
PK23GTA & LK100AN Installed
200 A
30
40
10
QO13040L200GC
383.00
PK23GTA & LK100AN Incl.

#6–250
#6–250

9
9

Convertible Mains—Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
QOM1 Main Frame Size—Convertible to Main Lugs (See page 8 or Lower Amperage Main Circuit Breaker (See page 7)—Copper Busj
12
12
0
QO112M100C
$234.00
PK9GTA
$ 8.90
12
8
QO11220M100C
275.00
PK15GTA
11.40
20
100 A
16
0
QO116M100C
263.00
PK12GTA
10.50
16
20
0
QO120M100C
297.00
PK15GTA
11.40
20

#4–1/0
#4–1/0
#4–1/0
#4–1/0

5
5
6
6

Convertible Mains—Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
QOM2 Main Frame Size—Convertible to Main Lugs (See page 8 or Lower Amperage Main Circuit Breaker (See page 7)—Copper Busj
20
30
10
QO12030M150C
$562.00
PK18GTA
$12.50
150 A
30
30
0
QO130M150C
580.00
PK18GTA
12.50
20
40
20
QO12040M200C
562.00
PK23GTA
14.20
30
30
0
QO130M200C
597.00
PK18GTA
12.50
200 A
30
40
10
QO13040M200C
649.00
PK23GTA
14.20
40
40
0
QO140M200C
758.00
PK23GTA
14.20

#4–250
#4–250
#4–250
#4–250
#4–250
#4–250

9
9
9
9
9
10

LOAD CENTERS

Mains
Rating
(A)

Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a Maximum number of single pole branch circuits utilizing QO and/or QOT
circuit breakers.
b Order F for flush device or S for surface device.
c Mains rating 25 A when Al wire is used.
d Will not accept QWIK-GARD® QO-GFI circuit breaker.
Auxiliary Gutter
e Use #10 maximum size wire for GFI circuit breakers.
UL Listed For Use With Standard 1Ø an 3Ø Load Centers For Riser Applications k. For Auxiliary Gutter-Load
f Main circuit breaker is a field-installed standard QO single pole circuit
Center
Compatibility, see Catalog 1100CT9901.
breaker. Order separately from page 3.
g 70 A max. branch circuit breaker and 70 A max. back fed main circuit
Catalog
Conduit
Price
Cover
Width
Height
Depth
breaker.
Number
Riser Size
h UL short circuit current rating depends on lowest interrupting rating of
3⁄4, 2, 21⁄2 or l 3
13.50
26.12
3.75
SDAG26
$225.
Flush
1
circuit breaker installed.
i UL Listed 5000 A short circuit current rating for corner grounded Delta
k One tap kit required for each riser wire.
systems. Use QO-H circuit breakers only.
l When used with B300 bolt-on hubs.
j 22,000 AIR main circuit breaker UL Listed for use ahead of QO, QOT and
QO-PL 10,000 AIR branch circuit breakers to permit their application on
systems with up to 22,000 A available fault current.
Tap Kits 120/240 Vac—UL Listed For Use With Auxiliary Gutters SDAG26

Accessories

Catalog
Number

Price

Use With
Auxiliary
Gutter
Catalog
Number

SDGT30020

$54.00 SDAG26

SDGT300300

80.00 SDAG26

SDGT300C10C

33.10 SDAG26

SDGT300C300C

46.90 SDAG26

QOGL20
Grounding
Terminals

27.10 SDAG26

Riser Wire
Lug Type
Mechanical
(Included)
Mechanical
(Included)
Anderson
#VCEL030516H1
(Not included)
Anderson
#VCEL030516H1
(Not included)
Mechanical
(Included)

Al/Cu Wire Size

Tap Off Wire
Lug Type

Al/Cu Wire Size

Mechanical
(1) #6–2/0
(Included)
Mechanical
(2) #6–300 kcmil
(1)
#6–300 kcmil
(Included)
Anderson
(2) #4–300 kcmil #VCEL02114S1
(1) #8–1/0
(Not Included)
Anderson
(2) #4–300 kcmil #VCEL030516H1 (1) #4–300 kcmil
(Not included)
(2) #6–300 kcmil

(2) #6–2/0

...

...

For additional information,
reference Catalog #1100CT9901.

© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE3A

Discount
Schedule

11

QO® & HOMELINE® Load Centers
Special Applications
Class 1130, 1170

www.SquareD.com
For the most up-to-date information

Load Center Value Pack

Spaces

1 Phase, 3 Wire—120/240 Vac—UL Listed—Convertible Mains—Factory-installed Main Circuit Breaker
Complete Load Center (Box, Interior and Cover) and Selected Branch Circuit Breakers
Mains
Rating
(A)

Max.
Max.
Number
Number
Single
of Tandem
Pole
Circuit
Circuitsa Breakers Catalog No.

Load Center
Box , Interior, Cover and Branch Circuit Breakers
Included Load Center/Circuit Breakers

Price

Equipment
Box No.
Main
Ground Bar Kit
See
Wire Size
(Order Separately) AWG/kcmil
Pages
19,
Al/Cu
Catalog No. Price
20

LOAD CENTERS

QO—Copper Bus—Order extra QO, QOT, QO-EPD, QO-GFI, QO-AFI branch circuit breakers from pages 3 and 4.
200

30

40

10

QOVP1

(1) QO13040M200C, (5) QO120

100

32

32

0

QOVP2

(1) QO132M100C, (5) QO120

$735.00 PK23GTA

$14.20

#4–250

9

559.00 PK18GTA

12.50

#4–2/0

8

HOMELINE—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 15.
I
N
D
O
O
R

200

30

40

10

HOMVP1

(1) HOM3040M200TC, (5) HOM120, (1) HOM230

722.00 Included

...

#4–250

10

200

30

40

10

HOMVP2

(1) HOM3040M200TC, (5) HOM115, (1) HOM230

722.00 Included

...

#4–250

10

100

20

20

0

HOMVP4

(1) HOM20M100C, (5) HOM115

352.00 PK15GTA

11.40

#4–2/0

8

100

20

20

0

HOMVP5

(1) HOM20M100C, (5) HOM120

352.00 PK15GTA

11.40

#4–2/0

8

150

30

30

0

HOMVP12

(1) HOM30M150C, (5) HOM120, (1) HOM230

655.00 PK23GTA

14.20

#4–250

10

200

30

40

10

HOMVP9

(1) HOM3040M200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250

885.00 Included

...

#4–250

10

200

30

40

10

HOMVP14

(1) HOM3040M200TC, (12) HOM120, (1) HOM230, (1) HOM250

885.00 Included

...

#4–250

10

200

30

40

10

HOMVPL1

(1) HOM3040L200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250

641.00 Included

...

#4–250

10

125

12

24

12

HOMVPL2

(1) HOM1224L125TC, (5) HOM120

235.00 Included

...

#6–2/0

6

20

HOMVPRB1 (1) HOM2040M200RB, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250

835.00 PK23GTA

14.20

#4–250

6R

HOMELINE—Rainproof
200

20

40

Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a Maximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers.

Riser
1 Phase—2 Wire 120/240 Vac—Offset Interior Wide Gutter—50 A Maximum Branch Circuit Breakerbc
Mains
Rating
(A)

I
N
D
O
O
R

Spaces

Max.
Number
Single
Pole
Circuitsa

Max.
Number
of Tandem
Circuit
Breakers

Load Center Box and Interior
Catalog Number

Equipment
Ground Bar Kit
(Order Separately)

Load Center Cover

Price

Catalog Number

Price

Catalog No.

Price

Main
Wire Size
AWG/kcmil
Al

Cu

Box No.
See
page 19

Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Rating
QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 7)—Copper Bus
125
125

12
20

24
30

12
10

QO11224L125WG
QO12030L125WG

$225.
310.

QOC20UFWG
QOC20UFWG

$35.
35.

PK15GTA
PK15GTA

$11.40
11.40

#6–2/0
#6–2/0

14
14

PK23GTA

14.20

#4–250

23

Fixed Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Rating
Copper Bus
200

30

40

10

QO13040L200WG

467.

QOC30UFWG

68.

Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a Maximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers.
b UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
c UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.

Panelboard-style Covers for Riser Panels
Mono-Flat® Front available for riser panels as an alternative to standard
load center cover listed above. Provides a low-profile, aesthetically
pleasing solution for high-traffic areas in upscale multi-family
applications. Deadfront included. Lock kit not provided. d
Mains Rating of
Load Center
(A)

Catalog Number

Price

125

NQC20FWG

$ 78.

200

NQC30FWG

120.

d Order catalog number PK4FL for field installable lock kit.

For additional information, reference Catalog #1100CT9901.

12

DE3A

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

QO® Load Centers
Accessories
Class 1130

www.SquareD.com
For the most up-to-date information

QO Load Center Accessories

Manual Transfer
Equipment Kit

Catalog Number

Price

Schedule

Secures circuit breaker to interior when used as a back-fed main. For QO612L100F/S, RB,
QO612L100DF/S, QO816L100F/S, RB, QO816L100DF/S and QO148L125GF/S, GRB load centers . . . . . . . . . . . . . .

PK2MB

4.80

DE3A

Secures circuit breaker to interior when used as a back-fed main. For 3Ø Load Centers . . . . . . . . . . . . . . . . . . . . . . . . .

PK3MB

9.80

DE3A

Secures circuit breaker to interior when used as a back-fed main for 2-pole QO 150–200 A circuit breakers. . . . . . . . . .

PK5RK

9.80

DE3A

Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main. PK4MB2LA
For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9.80

DE3A

Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main. PK4MB2HA
For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9.80

DE3A

For interlocking the handles of two 2-pole or one 2-pole and one 1-pole QO and Q1 circuit breakers mounted
side-by-side so that only one circuit breaker can be “ON’’ at a time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

QO2DTI

16.60

DE2E

QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit
breakers in dual power supply applications. Can be used with (2) 2-poles or (1) 2-pole and (1) 1-pole QO
circuit breakers in QO816L100 load centers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

QO2DTIM

42.00

DE2E

Secures TWO 2-pole circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for
back-up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. . . . . .

PK4DTIM4LA

68.00

DE3A

Secures TWO 2-pole circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for
back-up power supply applications. For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. . . . . .

PK4DTIM4HA

68.00

DE3A

Secures TWO 2-pole circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for
back-up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. . . . . .

PK4DTIM4LAL

68.00

DE3A

For use on “G” and “S” Series NEMA 1 and “G” and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2-pole main
circuit breaker of a load center (150–225 A) with a QO 2-pole (15–125 A) branch circuit breaker. Includes a retaining kit.

QOCGK2

70.00

DE3A

For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2-pole main circuit breaker of a load center
(150–225 A) with a QO 2-pole (15–125 A) branch circuit breaker. Includes a retaining kit.. . . . . . . . . . . . . . . . . . . . . . . . .

QORBGK2

70.00

DE3A

Miscellaneous
Cover Sealing Strap:

Provides means of sealing trim mounting screws on QO load center covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

QO1SE

2.40

DE3A

Surge Arresters:

For use on 1Ø3W, 150 Vac maximum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For use on 3Ø4W, 650 Vac maximum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SDSA1175
SDSA3650

61.00
165.00

DE1B
DE1B

QO SURGEBREAKER CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum.
HOMELINE SURGEBREAKER CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum.

QO2175SB
HOM2175SB

106.00
106.00

DE1B
DE1B

UL Listed for mounting SDSA1175 surge arrester into ground bar mounting holes on 1Ø convertible
main circuit breaker load centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

QOSAMK

7.60

DE3A

Generator Circuit Breaker
Interlock Kit

Surge Arrester Mounting Kit:

PK2MB
QOSAMK
QO2DTI

PK3MB

QO2DTI Installed

ON

1

OFF
OFF

6

ON

4

3

2

ON

OFF

5

ON

OFF

PK4DTIM4HA
© 2004 Schneider Electric
All Rights Reserved
6/7/04

QOCGK2 Installed

13

LOAD CENTERS

Description
Retaining Kit

QO® and HOMELINE® Load Centers
Accessories
Class 1130, 6610

www.SquareD.com
For the most up-to-date information

QO Load Center Accessories
Description

LOAD CENTERS

Price

Schedule

Filler Plates

Fills opening in covers if twistout is removed in error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fills main circuit breaker opening in convertible load center covers. . . . . . . . . . . . 100–125 A. . . . . . . . . . . . . . . . . . . . . . .
Fills main circuit breaker opening in convertible load center covers. . . . . . . . . . . . 150–225 A. . . . . . . . . . . . . . . . . . . . . . .
Fills main circuit breaker opening in three phase load center covers (S01 and S02 Series). . . . . . . . . . . . . . . . . . . . . . . .
Fills main circuit breaker opening in “Q” style three phase load center covers (S03 Series). . . . . . . . . . . . . . . . . . . . . . . .

QOFP
QOM1FP
QOM2FP
KFP
Q2FP

$ 2.40
13.50
13.50
13.50
13.50

DE3A
DE3A
DE3A
DE3A
DE3A

Lock Kits

Use with convertible mains, 1Ø and 3Ø 100–225 A, and fixed mains, 3Ø 125–225 A indoor load centers . . . . . . . . . . .
Use with 300 and 400 ampere indoor load centers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PK6FLa
PK4FL

62.00
60.00

DE3A
PE1A

Neutral / Ground Lugs

Field-installed for #12 to 2 Al or #14 to 4 Cu wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Field-installed for #6 to 2/0 Al/Cu wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Field-installed for #14 to 2/0 Al/Cu wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Field-installed for #2 to 3/0 Al/Cu wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Field-installed for #4 to 300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center . . . . . . . . . . . . . . . .

LK70AN
LK100AN
LK125AN
LK150AN
LK225AN

6.70
7.20
14.70
21.60
22.10

DE3A
DE3A
DE3A
DE3A
DE3A

Ground Bar Kits

Standard PK15GTA with a #1 to 4/0 Al/Cu Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard PK18GTA with a #1 to 4/0 Al/Cu Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard PK23GTA with a #1 to 4/0 Al/Cu Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PK15GTAL
PK18GTAL
PK23GTAL

23.30
25.20
27.10

DE3A
DE3A
DE3A

Insulator Kit for PK7GTA thru PK27GTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PKGTAB

29.20

DE3A

For padlocking main circuit breakers in convertible load centers, “OFF’’ . . . . . . . . 50–125 A, QOM1 Frame Size . . . . .
100–225 A, QOM2 Frame Size . . . . .

QOM1PA
QOM2PA

7.30
7.30

DE2E
DE2E

Handle Padlock Attachment:

Catalog Number

a QO612L100DF/S, QO816L100DF/S, QO612L100DFCU/SCU, QO816L100DFCU/SCU and QO403L60NF/S DO NOT have provisions for field-installed lock.

QOFP

PKGTAB
PK6FL
PK4FL

HOMELINE Load Center Accessories
Description

Catalog Number

Handle Padlock Attachment:

For padlocking main circuit breakers in convertible load center, “OFF”

Filler Plates

Fills opening in covers if twistout is removed in error

QOM1PA
QOM2PA

Price

Schedule

$ 7.30
7.30

DE2E
DE2E

HOMFP

2.10

DE3C

QOM1FP
QOM2FP

13.50
13.50

DE3A
DE3A

Field-installed for #14 to 2 Al or #14 to 4 Cu wire
Field-installed for #6 to 2/0 Al/Cu wire
Field-installed for #14 to 2/0 Al/Cu wire
Field-installed for #4 to 300 kcmil Al/Cu wire. Use in SeriesS, 150–225 A QO or HOM load center

LK70AN
LK100AN
LK125AN
LK225AN

6.70
7.20
14.70
22.10

DE3B
DE3B
DE3B
DE3A

Secures circuit breaker to interior when used as a back-fed main.
For HOM612L100F/S, RB and HOM48L125GC, GRB load centers.

HOM1RK

4.30

DE3C

Secures ONE circuit breaker right side of interior when used as a back-fed main. For 100–125 ampere convertible main HOM4RK2LA
load centers, Series S01 and S02

9.80

DE3C

Secures ONE circuit breaker right side of interior when used as a back-fed main. For 150–225 ampere convertible main HOM4RK2HA
load centers, Series S01 and S02

9.80

DE3C

9.80

DE3C

Fills main circuit breaker opening in convertible load centers
Neutral Lugs

50–125 A
100–225 A
100–125 A
150–225 A

Miscellaneous
Retaining Kit:

Secures circuit breaker to interior when used as a back-fed main for 2-pole 150–200 ampere circuit breakers

HOM5RK

Lock Kit:

Use with convertible indoor load center covers(Series S-1)

PK6FL

62.00

DE3A

Generator Circuit
Breaker Interlock Kit

For use on “S” Series NEMA 1 and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2-pole main circuit breaker
of a load center (150–225 A) with a HOMELINE 2-pole 15–125 A) branch circuit breaker.

HOMCGK2

70.00

DE3D

For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2-pole main circuit breaker of a load center
(150–225 A) with a HOMELINE 2-pole (15–125 A) branch circuit breaker.

HOMRBGK2

70.00

DE3D

Voltage Testers
Solenoid Type with polarity indication and slotted receptacles for holding prods. UL and CSA Listed.
Description
The

Voltage Tester 120-240-480-600 Vac 50/60 Hz; 120-240-600 Vdc

Type
6610 VT1

Price

Schedule

$67.00

DE3B

Same as VT-1 except with fused leads

6610 VT1S

74.00

DE3B

Deluxe Simulated Leather Carrying Case

6610 L2

39.30

DE3B

Replacement Polarity Indication Cap b

6610 PC1

8.00

DE3B

Replacement Leads b

6610 P1

25.70

DE3B

Fused Replacement Leads b

6610 P1S

35.50

DE3B

b IMPORTANT: Will fit only Class 6610 Series A testers and Catalog Number 5008, Series B testers. Will not fit 5008 Pre-Series B testers. Leads must be
replaced as a unit. Replacement of individual lead components must not be attempted.

Wiggy® Voltage Tester

14

© 2004 Schneider Electric
All Rights Reserved
6/7/04

HOMELINE® Circuit Breakers
Class 750, 751, 911

www.SquareD.com
For the most up-to-date information

Plug-On Circuit Breakers—UL Listed 10,000 Amperes
RMS Symmetrical Interrupting Rating (AIR)
The Square D HOMELINE circuit breakers are in a 1-inch wide industrystandard format for 1-pole circuit breakers. They are designed to plug
into HOMELINE load centers that are available from 4 to 42 circuits.
The Square D exclusive QWIK-OPEN® mechanism is standard on all
15 A and 20 A circuit breakers with a trip reaction within 1/60th of a
second.
HOM
2-pole—120/240 Vac
1-pole—120/240 Vac
Common Trip
Catalog Number
Price
Catalog Number
Price
10,000 Amperes RMS—UL Listed Interrupting Rating
15
HOM115 ab
$17.50
HOM215 b
$ 40.30
20
HOM120 ab
17.50
HOM220 b
40.30
25
HOM125 b
17.50
HOM225 b
40.30
30
HOM130 b
17.50
HOM230 b
40.30
35
...
...
HOM235 b
40.30
40
HOM140 b
17.50
HOM240 b
40.30
45
...
...
HOM245 b
40.30
50
HOM150 b
17.50
HOM250 b
40.30
60
...
...
HOM260 b
40.30
70
...
...
HOM270 b
82.00
80
...
...
HOM280 b
112.00
90
...
...
HOM290 b
112.00
100
...
...
HOM2100 b
112.00
110
...
...
HOM2110 b
246.00
125
...
...
HOM2125 b
246.00
150
...
...
HOM2150BB bc
285.00
175
...
...
HOM2175BB bc
285.00
200
...
...
HOM2200BB bc
285.00
Ampere
Rating

Ampere Rating d
2-pole Tandem—120/240 Vac (Two Spaces Required)
1P
2P
Catalog No.
Price
10,000 AIR
(2) 15
15
HOMT1515215 b
$80.00
(2) 15
20
HOMT1515220 b
80.00
(2) 15
25
HOMT1515225 b
80.00
(2) 15
30
HOMT1515230 b
80.00
(2) 15
40
HOMT1515240 b
80.00
(2) 15
50
HOMT1515250 b
80.00
(2) 20
20
HOMT2020220 b
80.00
(2) 20
25
HOMT2020225 b
80.00
(2) 20
30
HOMT2020230 b
80.00
(2) 20
40
HOMT2020240 b
80.00
(2) 20
50
HOMT2020250 b
80.00
Typical catalog number (e.g. HOMT 1515230) represents two single-pole, outer poles (two 15 A
1P CBs) and one 2-pole inner circuit breaker with common trip (one 30 A 2P CB).

HOM 1-pole

HOM 2-pole

HOMT
1-pole

HOMT Quad
Breaker

1 Space
Required

2 Spaces Required

1 Space
Required

2 Spaces Required

HOM 1-pole
AFI
(Arc Fault
Circuit
Interrupter)

HOM 1-pole GFI
(With Ground
Fault Circuit
Interrupter)

HOM 2-pole GFI
(With Ground
Fault
Circuit Interrupter)

HOM2200BB
Branch
Breaker

2 Spaces
Required

4 Spaces
Required

HOM-HM
High magnetic trip circuit breakers are recommended for applications where high initial inrush
current may occur.
1-pole—120/240 Vac
Catalog Number
Price
HOM115HMb
$18.40
HOM120HMb
18.40

Amperes
15
20

2-poles
...
...
...

HOM-AFI
HOMELINE Arc Fault Circuit Interrupters—Provide overload and short circuit protection, plus arc
fault protection in accordance with UL 1699.
Ampere Rating

Poles 120 Vac

Catalog Number

Price

15
20

1
1

HOM115AFIb
HOM120AFIb

$150.00
150.00

Circuit Breaker Wire Sizese
Breaker Type

Ampere Rating

HOM
1-pole

15–30
40–50
15–30
35–70
80–125
150–200
15–30
40–50
15–20
15–50

HOM-GFI
HOM-GFI circuit breakers provide overload and short circuit protection, combined with Class A
ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault
current to ground is 6 milliamperes or more.
Ampere
Rating

1-pole—120 Vac
1 Space Required
Catalog Number
Price

10,000 AIR
15
20
30
40
50

HOM-EPD
Amperes
10,000 AIR
15
20
25
30
40
50

2-pole—120/240 Vac
Common Trip
2 Spaces Required
Catalog Number
Price

1 Space
Required

1 Space
Required

HOM
2-pole
HOMT and Quad
Quad Only
HOM-GFI - 1-pole
HOM-GFI - 2-pole

Wire Size (AWG/kcmil)
Aluminum
Copper
#14–8
#14–8 or (2) #14–10
#8–2
#8–2
#14–8
#14–8 or (2) #14–10
#8–2
#8–2
#4–2/0
#4–2/0
#4–300
#4–300
#14–8
#14–8
#6–#12
#6–#14
#14–10
#14–10
#12–4
#14–6

Accessories
HOM115GFI
HOM120GFI
...
...
...

$141.00
141.00
...
...
...

HOM215GFI
HOM220GFI
HOM230GFI
HOM240GFI
HOM250GFI

$275.00
275.00
275.00
275.00
275.00

HOMELINE Equipment Protection Device—Circuit Breakers with 30 mA
Equipment Ground Fault Protection (UL Listed)
2-pole—120/240 Vac
1-pole—120 Vac
Common Trip
Catalog Number
Price
Catalog Number
Price
HOM115EPD
HOM120EPD
...
...
...
...

$249.00
249.00
...
...
...
...

HOM215EPD
HOM220EPD
HOM225EPD
HOM230EPD
HOM240EPD
HOM250EPD

$440.00
440.00
440.00
440.00
440.00
440.00

HOMT Tandem Circuit Breakers
Ampere Rating d
10,000 AIR
15 and 15
15 and 20
20 and 20
30 and 15
30 and 20

1-pole Tandem—120/240 Vac (One Space Required)
Catalog No.
Price
HOMT1515 b
HOMT1520 b
HOMT2020 b
HOMT3015 b
HOMT3020 b

$34.90
34.90
34.90
34.90
34.90

a UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting
loads.
b UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment
having motor group combinations and marked for use with HACR type circuit breakers.
c Requires four spaces (#1–300 kcmil Al/Cu). Use only in single phase panel rated 150 A or
greater.
© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE3D

jDE3C

Description

Catalog No.

HANDLE ATTACHMENTS
Handle Tie: Converts any two adjacent 120/240 Vac
single HOM breakers to independent trip
2-pole
Handle Tie: Converts any two adjacent 120/240 Vac
single-pole side-by-side HOMT breakers to independent
trip 2-pole
Handle Clamp: Clamp for holding HOM single-pole handle in “ON’’
or “OFF’’ position
Handle Blocking Device: Attaches to standard HOM 2-pole circuit
breakers for holding the handle in the “OFF” position
Handle Padlock Attachment: For padlocking 1-pole
Standard HOM breakers in “ON’’ or “OFF’’ position.
A
Handle Padlock Attachment: For padlocking 2-pole 15–70
80–125 A
Standard HOM breakers in “ON’’ or “OFF’’ position
150–200 A
Handle Padlock Attachment: For padlocking center
poles of Homeline Quad breakers in “OFF” position.
Handle Padlock Attachment: For padlocking main
circuit breakers in convertible load center, “OFF”
SUB-FEED LUGS
125 A 2-pole plug-on—2 spaces required
225 A 2-pole plug-on—4 spaces required

Price

HOM1HT

$ 2.30j

HOMTHT

2.50j

QO1LO

2.50v

HOM2HBD

7.10j

HOM1PA
HOM2PALA
HOM2PAHA
HOM2PAVHA

HOMQPA
50–125 A QOM1PAf
100–225 A QOM2PAf
HOML2125
HOML2225c

6.60j
6.60j
6.60j
33.60j
6.60
7.20v
7.20v
31.70
197.00

d 15–20 A tandem or quad tandem circuit breakers are suitable for use with 60°C or 75°C
conductors. 25–50 A tandem or quad tandem circuit breakers are suitable for use with 75°C
conductors only.
e 15–30 A circuit breakers are suitable for use with 60°C or 75°C conductors. 40–125 A circuit
breakers are suitable for use with 75°C conductors.
f 50–125 A QOM1 frame size; 100–225 A QOM2 frame size.

vDE2E

Discount
Schedule

15

LOAD CENTERS

HOMT Quad Tandem Circuit Breakers

HOMELINE® Load Centers
Series Rating
Class 1170

www.SquareD.com
For the most up-to-date information

The rating of the load center is equal to the lowest interrupting rating of any circuit breaker installed or combination series connected circuit breaker.
Additional or replacement circuit breakers MUST have an interrupting and voltage rating equal to or greater than that of the circuit breaker with the lowest
interrupting and voltage rating presently installed. See load center interior for circuit breaker types.
Short Circuit Current Rating

LOAD CENTERS

Maxium
Short Circuit
Current Rating
(RMS Symmetrical)
10,000

Load Center
Voltage Rating
240 Vac Max.
Systems Voltage
120/240 Vac, 1 Phase 3 Wire

Remote Square D
Circuit Breaker
Catalog
Designation
b

Current Rating
Amperes Max.

Integral Square D
Circuit Breaker
Catalog
Designation
b

Current
Rating
Amperes Max.

…

…

…

…

…

…

QOM-VH
…

225
…

Square D Branch Circuit Breaker
Catalog
Designation
bc

Current Rating Amperes
1-pole

2-pole

HOM

15–50

15–200 a

HOMT

15–30

15–50

HOM

15–50

15–200 a

HOMT

15–30

15–50

HOM

15–50

15–200 a

Series Combination Short Circuit Current Rating

22,000

120/240 Vac, 1 Phase 3 Wire
QO-VH

42,000
25,000
65,000
100,000

120/240 Vac, 1 Phase 3 Wire
120/240 Vac, 1 Phase 3 Wire
120/240 Vac, 1 Phase 3 Wire
120/240 Vac, 1 Phase 3 Wire

QOH
QD
QG
QJ

200
125
225
225
225

…
…
…
…
…

…
…
…
…
…

HOMT

15–30

15–50

HOM

15–50

15–200 a

HOMT

15–30

15–50

HOM

15–50

15–200 a

HOMT

15–30

15–50

HOM

15–50

15–200 a

HOMT

15–30

15–50

HOM

15–50

15–200 a

HOMT

15–30

15–50

a 100 Amperes maximum branch circuit breaker in load centers with 125 A maximum mains rating.
b See circuit breaker for voltage and interrupting rating.
c HOM includes suffixes: GFI and AFI.

16

© 2004 Schneider Electric
All Rights Reserved
6/7/04

HOMELINE® Load Centers
Indoor—Single Phase, Main Lug, Main Circuit Breaker
Class 1170

www.SquareD.com
For the most up-to-date information

Single Phase Three Wire—120/240 Vac—UL Listed—10,000 RMS Sym. Amperes Short Circuit Current Rating
Mains
Rating
(A)

Spaces

Max.
Number
Single
Pole
Circuitsa

Max.
Number of
Tandem
Circuit
Breakers

Load Center
Box, Interior and Cover b
Catalog Number

Main Wire Size
AWG/kcmil

Price
(DE3C)

Al

Cu

Equipment Ground Bar Kit
(Order Separately)
Catalog Number

Price
(DE3A)

PK3GTA1

$ 7.60

Box No.
See
page 19

Main Lugs—Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from page 15
Factory-installed Fixed Main Lugs
2

4

2

HOM24L70F/S c d

6

12

6

HOM612L100F/S c e

52.00

125

4

8

4

HOM48L125GC

57.00

$ 39.20

#12–3

#14–4
#8–1

#12–2/0

PK7GTA
#14–2/0

7.80

PK7GTA Factory-included

2
4
21

LOAD CENTERS

70
100

Convertible Mains—Factory-installed Main Lugs
QOM1 Main Frame Size—Convertible to 22,000 AIR Main Circuit Breaker (See page 18)

125

8
8
12
12
16
20
20
24

16
16
12
24
24
20
24
24

8
8
0
12
8
0
4
0

HOM816L125C
HOM816L125TC
HOM12L125C
HOM1224L125TC
HOM1624L125C
HOM20L125C
HOM2024L125TC
HOM24L125TC

88.00
100.00
116.00
136.00
173.00
158.00
192.00
229.00

#6–2/0

PK15GTA
Factory-installed
PK15GTA
Factory-installed
PK15GTA
PK15GTA
Factory-installed
Factory-installed

11.40
...
11.40
...
11.40
11.40
...
...

6
6
6
6
8
8
8
8

14.20

10

Convertible Mains—Factory-installed Main Lugs
QOM2 Main Frame Size—Convertible to 22,000 AIR Main Circuit Breaker (See page 18)
150

30

30

0

HOM30L150C

250.00

#6–250

PK23GTA

200

16
16
20

32
32
40

16
16
20

HOM1632L200TC
HOM1632L200TCFTf
HOM2040L200TC

238.00
383.00
278.00

#6–250

Factory-installed

...

9
10
9

200

30
30
30
40

30
30
40
40

0
0
10
0

HOM30L200C
HOM30L200TC
HOM3040L200TC
HOM40L200C

280.00
309.00
319.00
412.00

#6–250

PK23GTA
Factory-installed
Factory-installed
PK23GTA

14.20
...
...
14.20

10
10
10
12

225

42

42

0

HOM42L225C

488.00

#6–250

PK23GTA

14.20

12

I
N Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
D Convertible Mains—Factory-installed Main Circuit Breaker
O QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 18)
O
8
16
8
HOM816M100C
$210.00
#6–1
PK15GTA
R
8
16
8
HOM816M100TC
222.00
#6–1
Factory-installed
100

125

12
12
20
24
30

12
24
20
24
30

0
12
0
0
0

HOM12M100C
HOM1224M100TC
HOM20M100C
HOM24M100C
HOM30M100C

196.00
256.00
264.00
342.00
448.00

#4–2/0
#4–2/0
#4–2/0
#4–2/0
#4–2/0

PK15GTA
Factory-installed
PK15GTA
PK15GTA
PK23GTA

11.40
...
11.40
...
11.40
11.40
14.20

5
5
6
6
8
8
10

12
12
24
30

24
24
24
30

12
12
0
0

HOM1224M125C
HOM1224M125TC
HOM24M125C
HOM30M125C

404.00
413.00
473.00
541.00

#4–2/0

PK15GTA
Factory-installed
PK15GTA
PK23GTA

11.40
...
11.40
14.20

6
6
8
10

Factory-installed
Factory-installed
PK23GTA

...
...
14.20

9
9
10

Factory-installed
Factory-installed
PK23GTA
Factory-installed

...
...
14.20
...

9
9
9
9

PK23GTA
Factory-installed
PK23GTA
PK23GTA

14.20
...
14.20
14.20

10
10
12
12

PK23GTA

14.20

12

Factory-installed
Factory-installed
Factory-installed

...
...
...

9
9
10

Convertible Mains—Factory-installed Main Circuit Breaker
QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 18)
150

200

225

16
20
30

32
30
30

16
10
0

HOM1632M150TC
HOM2030M150TC
HOM30M150C

424.00
500.00
517.00

12
16
20
20

24
32
40
40

12
16
20
20

HOM1224M200TC
HOM1632M200TC
HOM2040M200C
HOM2040M200TC

381.00
450.00
474.00
509.00

30
30
40
42

30
40
40
42

0
10
0
0

HOM30M200C
HOM3040M200TC
HOM40M200C
HOM42M200C

532.00
594.00
679.00
729.00

42

42

0

HOM42M225C

744.00

#4–250

#4–250

#4–250

Universal Mains—No Factory-installed Main Circuit Breaker or Main Lugs
QOM2 Main Frame Size—Field-install 22,000 AIR Main Circuit Breaker or Main Lugs (See page 18)
200

16
20
30

32
40
40

16
20
10

HOM1632U200TC
HOM2040U200TC
HOM3040U200TC

195.00
238.00
353.00

#4–250

Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a Maximum number of single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
b C at end of catalog number indicates combination flush/surface cover included with device.
c F/S at end of catalog number indicates to order F for flush device or S for surface device. The cover does not have a door.
d HOM-GFI branch circuit breaker is limited to number 10 maximum wire.
e 70 A maximum back feed main circuit breaker.
f Supplied with feed-thru lugs.

For additional information, reference Catalog #1100CT9901.
© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE3A

DE3C

Discount
Schedule

17

HOMELINE® Load Centers
Rainproof—Single Phase, Main Lug, Main Circuit Breaker
Class 1170

www.SquareD.com
For the most up-to-date information

Single Phase Three Wire—120/240 Vac—UL Listed—10,000 RMS Sym. Amperes Short Circuit Current Rating
Main Lugs—Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from page 15
Mains
Rating
(A)

Spaces

a Max.
Number
Single Pole
Circuits

Max.
Number of
Tandem Circuit
Breakers

Load Center
Box, Interior and Cover
Catalog Number

Main Wire Size
AWG/kcmil

Price
(DE3C)

Al

#12–3

Cu

Equipment Ground Bar Kit
(Order Separately)

Box No.
See
page 20

Catalog Number

Price
(DE3A)

PK4GTA

$ 7.20

PK7GTA

7.80

2R

PK7GTA Factory-included

15R

LOAD CENTERS

Factory-installed Fixed Main Lugs
70

2

4

2

HOM24L70RB b

$ 74.00

100

6

12

6

HOM612L100RB

86.00

#14–4
#8–1

125
4
8
4
HOM48L125GRB
91.00
#12–2/0
#14–2/0
R
A Convertible Mains—Factory-installed Main Lugs c
I QOM1 Main Frame Size—Convertible to 22,000 AIR Main Circuit Breaker (See Below)
N
8
16
8
HOM816L125RB
165.00
P
12
12
0
HOM12L125RB
156.00
125
#6–2/0
R
12
24
12
HOM1224L125RB
185.00
20
20
0
HOM20L125RB
255.00
O
O
F Convertible Mains—Factory-installed Main Lugs c
QOM2 Main Frame Size—Convertible to 22,000 AIR Main Circuit Breaker (See Below)
12
20
30
40

200

12
40
30
40

0
20
0
0

HOM12L200RB
HOM2040L200RB
HOM30L200RB
HOM40L200RB

282.00
373.00
391.00
607.00

#6–250

1R

PK15GTA
PK15GTA
PK15GTA
PK15GTA

11.40
11.40
11.40
11.40

3R
3R
3R
4R

PK23GTA
PK23GTA
PK23GTA
PK23GTA

14.20
14.20
14.20
14.20

5R
6R
7R
14R

Main Circuit Breaker— 22,000 RMS Sym. Amperes Short Circuit Current Rating d
Convertible Mains—Factory-installed Main Circuit Breaker c
QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below)
100

8
12
20

16
12
20

8
0
0

HOM816M100RB
HOM12M100RB
HOM20M100RB

286.00
277.00
354.00

#4–2/0

PK15GTA
PK15GTA
PK15GTA

11.40
11.40
11.40

3R
3R
4R

125

24

24

0

HOM24M125RB

572.00

#4–2/0

PK15GTA

11.40

6R

Convertible Mains—Factory-installed Main Circuit Breaker c
QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below)

R
150
30
30
0
HOM30M150RB
A
20
40
20
HOM2040M200RB
I
30
30
0
HOM30M200RB
200
N
30
40
10
HOM3040M200RB
40
40
0
HOM40M200RB
P
R
16
24
8
HOM1624M225RB
225
42
42
0
HOM42M225RB
O
O Factory-installed Main Circuit Breaker with Feed-thru Lugsc
F

685.00

#4–250

PK23GTA

14.20

7R

581.00
669.00
768.00
851.00

#4–250

PK23GTA
PK23GTA
PK23GTA
PK23GTA

14.20
14.20
14.20
14.20

6R
7R
7R
14R

788.00
882.00

#4–250

PK15GTA
PK23GTA

11.40
14.20

7R
14R

150

8

16

8

HOM816M150FTRB

523.00

#4–250

PK15GTAL

23.30

6R

200 e

8

16

8

HOM816M200FTRB

523.00

#4–250

PK15GTAL

23.30

6R

PK15GTAL

23.30

6R

Universal Main with Feed-thru Lugs—No Factory-installed Main Circuit Breaker c
QOM2 Main Frame Size—Field-install 22,000 AIR Main Circuit Breaker (See Kits Below)
200

8

16

8

HOM816U200FTRB

Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a Maximum number of single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
b HOM-GFI branch circuit breaker is limited to number 10 maximum wire.
c Side hinge door device allow 11⁄4" on left side for door to open.
d 22,000 AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10,000 AIR
branch circuit breakers to permit their application on systems with up to 22,000 A available
fault current.
e Rated 200 A when using copper wire. Reference NEC® Table 310.15(B)(6) when using
Al wire.

#4–250

Main Circuit Breaker Kits
Field-installable Main Circuit Breaker (Convertible Load Centers Only)
Main
Circuit Breaker
Rating (A)
i

Use With
Convertible Load
Center
Mains Rating

22,000 AIR j
Main Circuit
Breaker

Price
(DE3A)

Lug Wire Size k
AWG/kcmil
Al or Cu

QOM1 Frame Size

Main Lug Kits

QOL125

QOL225

50
60

100–125
100–125

QOM50VH
QOM60VH

$ 93.00
93.00

70
80
90

100–125
100–125
100–125

QOM70VH
QOM80VH
QOM90VH

93.00
134.00
134.00

100
110
125

100–125
125
125

QOM100VH
QOM110VH
QOM125VH

134.00
312.00
312.00

QOM2100VH
QOM2125VH
QOM2150VH
QOM2175VH
QOM2200VH
QOM2225VH

312.00
312.00
312.00
312.00
312.00
312.00

#12–2/0

QOM2 Frame Size l

Field-installable Main Lugs (Convertible Load Centers Only)
Main Lug f
Ampere Rating

Use On
Convertible Load Center
With Mains Rating

Catalog
Number

Price
(DE3A)

Lug Wire Size g
AWG/kcmil
Al or Cu

125
225

100–125
150–225

QOL125h
QOL225h

$29.40
69.00

#6–2/0
#6–300

f Do not exceed the load center mains rating.
g Wire Range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size
permitted in a particular load center per UL, see pages 17, 18 under main wire size.
h If main circuit breaker knockout has been removed from the load center’s trim, order
appropriate filler plate from page 14.

For additional information, reference Catalog #1100CT9901.

18

297.00

DE3A

DE3C

100
125
150
175
200
225

150–225
150–225
150–225
200–225
200–225
225

#4–300

i Do not exceed the load center mains rating.
j 22,000 AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10,000 AIR
branch circuit breakers to permit their application on systems with up to 22,000 amperes
available fault current.
k Wire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find
out maximum wire size permitted in a particular load center per UL, see pages 17,18 under
Main Wire Size.
l Add suffix 1021 for 120, 208, 240 Vac shunt trip. Add $126.00.

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

QO® and HOMELINE® Load Centers
Indoor—Dimensions, Knockouts
Class 1130, 1170

www.SquareD.com
For the most up-to-date information

Knockout Information and Enclosure Dimensions
Indoor
Dimensions

Box
No.

IN

1
2

H

D

W

Box
No.

A

H

IN

mm

IN

mm

IN

mm

mm

IN

mm

IN

mm

3.81

97

6.72

171

3.00

76

13

5.88

149

13.12

333

3.38

86

4.81

122

9.30

236

3.19

81

14

14.25

362

20.92

531

3.75

95

3

4.81

122

9.30

236

3.19

81

15

20.00

508

50.00

1270

5.75

146

4

8.88

226

12.57

319

3.80

97

16

20.00

508

68.00

1727

5.75

146

5

14.25

362

14.92

379

3.75

95

17

20.00

508

53.00

1346

5.75

146

5.88

149

16.12

409

3.38

86

7.56

192

23.12

587

4.25

108

6

14.25

362

17.92

455

3.75

95

18

7

14.25

362

20.92

531

3.75

95

19

95

20

9.62

244

26.12

663

4.75

8

14.25

362

26.04

661

3.75

9

14.25

362

29.86

758

3.75

95

21

8.88

226

14.80

376

3.80

97

14.25

362

33.78

858

3.75

95

22

8.55

217

23.92

608

3.95

100

11

14.25

362

37.98

965

3.75

95

23

14.25

362

29.86

758

3.75

95

12

14.25

362

39.37

1000

3.75

95

B,C,D,E
B,C,D,E

C,D,E,F,G

A A,B

C,D,E,F,G

A

B

1⁄2

3⁄4

C

D

E

1

11⁄4

11⁄2

A

A

Box 1

B,C,D,E
A A,B

C,D,E,F,G

G

2

21⁄2

A

B,C,D,E

A A,B
B,C,D,E

A
A
B,C,D,E
A,B,C,D

B,C,D,E

I

3

31⁄2

Box 5

Box 4

C,D,E,F,G

D,E,F,G

B,C,D,E
C,D,E,F
A A,B
B,C,D,E
D,E,F,G

C,D,E,F,G

D,E,F,G

A A,B
B,C,D,E
D,E,F,G

B,C

B,C,D,E

C,D,E,F

B,C

A,B

B,C,D,E

C,D,E,F

C,D,E,F,G

C,D,E,F

A,B

H

A A,B

B,C,D,E

B,C,D,E

B,C,D,E

B,C,D,E
C,D,E,F

C,D,E,F

Box 3

Box 2

A,B

A

A,B

B,C,D,E

F

A,B,C

A

A,B,C

Knockouts
Symbol

A,B,C

A

121

10

Conduit
Size

A,B,C,D

A,B,C

D

LOAD CENTERS

Dimensions
W

A,B
A,B

A

A,B
A
A

A

A,B,C,D

A,B,C,D

Box 6

B,C,D,E
C,D,E,F

C,D,E,F,G

D,E,F,G

B,C,D,E

Box 7

A A,B
B,C,D,E
D,E,F,G

B,C,D,E
B,C,D,E

A,B,C,D

Box 8

C,D,E,F,G

D,E,F,G

A,B,C,D
C,D,E,F

D,E,F,G

A,B,C,D
C,D,E,F

D,E,F,G

Box 10

Box 9

A A,B
C,D,E,F
D,E,F,G

A,B,C
A
C,D,E,F

A,B

D,E,F,G
A,B

B,C,D,E

C,D,E,F

A,B,C,D

D,E,F,G,H

D,E,F,G,H,I

C,D,E,F

B,C

B,C

A,B
A,B
A,B
A
A
A
A,B,C,D
B,C,D,E

Box 13

Box 14
A,B,C,D
C,D,E,F

D,E,F,G

A,B,C,D
B,C,D,E

C,D,E,F

Box 15, 16, 17

Box 12

Box 11

A,B,C

C,D,E,F E,F,G,H

C,D,E,F

A

D,E,F,G

A,B,C,D

A,B

D,E,F,G

A

C,D,E,F

B,C,D,E

D,E,F,G

D,E,F,G
A,B
B,C,D,E
D,E,F,G

B,C,D,E

B,C,D,E

B,C

B,C,D,E

B,C,D,E
B,C,D,E

Box 18

Box 19

Box 20

A,B

A,B

A

C,D,E,F

A

Box 22

Box 21
A,B,C,D
C,D,E,F

D,E,F,G

Box 23

© 2004 Schneider Electric
All Rights Reserved
6/7/04

19

QO® and HOMELINE® Load Centers
Rainproof—Dimensions, Knockouts, Bolt-On Hubs
Class 1130, 1170

www.SquareD.com
For the most up-to-date information

Enclosure Dimensions

2 1⁄2" Hub Maximum

2 1⁄2" Hub Maximum

Dimensions
W

Box No.
A,B,C
A
A,B

A,B,C,D

Box 1NM

B,C,D,E A

Box 1R

B,C,D,E
B,C,D,E

A,B

Box 2R
2 ⁄2" Hub Maximum
1

LOAD CENTERS

2 1⁄2" Hub Maximum

C,D,E,F,G
C,D,E,F,G

C,D,E,F

A,B,C
A A,B C,D,E,F,G

C,D,E,F
C,D,E,F

Box 3R, 4R

A,B,C
A A,B C,D,E,F,G

C,D,E,F

Box 5R

2 1⁄2" Hub Maximum

H

D

IN

mm

IN

mm

IN

1NM

6.52

166

8.79

223

3.90

mm
99

1Ra

4.88

124

9.38

238

4.00

102

2R

8.88

226

12.65

321

4.27

108

3R

14.75

375

18.92

481

4.52

115

4R

14.75

375

22.06

560

4.52

115

5R

14.75

375

26.04

661

4.52

115

6R

14.75

375

29.86

758

4.52

115

7R

14.75

375

33.78

858

4.52

115

8R

14.75

375

37.98

965

4.52

115

9R

4.56

116

6.50

165

3.88

99

10R

6.92

176

13.18

335

4.12

105

11R

7.56

192

23.24

590

4.75

121

12R

9.62

244

26.24

666

5.50

140

13R

6.92

176

16.18

411

4.12

105

14R

14.75

375

39.37

1000

4.52

115

15R

8.88

226

14.80

376

4.27

108

16R

8.55

217

24.75

629

4.16

106

a HOME250SPA top endwall has no hub opening.

Knockout Information
Knockouts
C,D,E,F,G
A,B,C

Symbol

A

B

Conduit
Size

1⁄2

3⁄4

C

D

E

1

11⁄4

11⁄2

F

G

H

2

21⁄2

3

Box 9R
C,D,E,F

A,B,C
A A,B C,D,E,F,G

2 1⁄2" Hub Maximum

C,D,E,F

Box 6R, 7R, 8R
2 1⁄2" Hub Maximum

2 1⁄2" Hub Maximum

2 1⁄2" Hub Maximum
2 ⁄2" Hub Maximum

2 ⁄2" Hub Maximum

1

1

A,B
C,D,E,F,G
C,D,E,F

B,C,D,E

A,B,C,D

B,C,D,E

C,D,E,F

A,B

Box 16R

Box 15R

E,F

E,F,G,H

Box 11R

B,C,D,E

A
B,C,D,E

D,E,F,G
D,E,F,G

Box 10R, 13R

B,C,D,E

Box 12R
C,D,E,F

Bolt-On Hubs

A,B,C
A A,B C,D,E,F,G

C,D,E,F

Box 14R

Square D equipment with “R’’ or “RB’’ suffix, designated rainproof NEMA 3R rainproof construction, utilizes bolt-on hubs listed below. “RB’’ devices will
accept 3⁄4" through 2" bolt-on hubs without the use of reducers. Off-center conduit thread openings and elongated mounting holes provide quick and
easy adjustment to eliminate costly conduit offsets and bends. Catalog suffix “R’’ devices require 3" through 4" field cut opening. Hubs are suitable for
use with conduit having ANSI standard taper pipe thread.
Bolt-On Hubs UL Listed For “RB’’ Devices
3⁄4"

Conduit Size

11⁄4"

1"

11⁄2"

2"

21⁄2"

Hub Cat. No.

B075

B100

B125

B150

B200

B250

Price

$22.20

$22.20

$22.20

$22.20

$40.90

$68.00

Note: Closing cap (catalog number BCAP) is provided factory-installed on each device having “RB’’ suffix. Price if
ordered separately; $2.50

Bolt-On Hubs UL Listed For Mounting In Field Cut Opening
Conduit Size

3"

31⁄2"

4"

Hub Cat. No.

B300

B350

B400

Price

$124.00

$200.00

$245.00

“RB’’ Hub

20

DE1A

Discount
Schedule

Designed for mounting in field cut opening.
Includes gasket and four mounting bolts
and nuts.

© 2004 Schneider Electric
All Rights Reserved
6/7/04

QO® Load Centers
Wiring Diagrams—Single Phase
Class 1130

www.SquareD.com
For the most up-to-date information

1 Phase 3 Wire Main Lugs
S
N

S/N

S
N

G/B

QO2L30S
QO2L40RB

S
N

S
N

QO11224L125G
QO11224L125GC
QO11224L125GRB
QO11224L125GWGC

S
N

S
N

S
N

QO116L125G

S
N

G
B

QO24L60NRNMq
QO24L70F/S
QO24L70RB
QO24L70TSq

QO2L30TTSq

S
N

S
N

S
N

S
N

S
N

QO11624L125G
QO11624L125GRB

S
N

S
N

S
N

S/N

S
N

QO24L50TTSq

S
N

S
N

QO612L100DFCU/SCU
QO612L100DF/S
QO612L100DTF/Sq
QO612L100F/S
QO612L100RB
QO612L100RBCU
QO612L100TF/Sq
QO612L100TRBq

QO816L100DF/S
QO816L100DFCU/SCU
QO816L100DTF/Sq
QO816L100F/S
QO816L100RB
QO816L100RBCU
QO816L100TF/Sq
S
N

QO112L125G
QO112L125GC
QO112L125GRB
QO112L200G
QO112L200GRB

S
N

S
N

S
N

QO120L125G
QO120L125GC

S
N

S
N

S
N

S
N

QO12024L125G
QO12024L125GWGC

S
N

QO12030L150G

S
N

S
N

S
N

G
B

QO124L125G
QO124L125GRB
QO124L150G

QO12436L200TFT
QO130L150G
QO130L150GRB
QO130L200G
QO130L200GRB

QO132L125G

S/N

S/N

S/N

QO13040L200G
QO13040L200GC
QO13040L200GRB
QO13040L200WG

QO140L200G
QO140L200GRB

S/N

S/N

QON12LS400

QO142L225G
QO142L225GRB

Main Main

QO148L125GF/S
QO148L125GRB

QON30LS400

QO48M30DSGP
QO48M60DSGP

Generator Panel

QON42LS400

1 Phase 3 Wire Main Breaker
S
N

Line

Main

S
N

Main

S
N

S
N

Main

S
N

S
N

Main

S
N

S
N

Main

S
N

S
N

Main

S
N

S
F
S/N

G/B

QO35FM30TTFq
QO35FM30TTSq

QO1612M125FTRB

QO1816M150FTRB
QO1816M200FTRB

QO112M100
QO112M100C
QO112M100RB

QO116M100
QO116M100C
QO116M100RB

QO11220M100C
QO120M100
QO120M100C
QO120M100RB

q Includes Factory Installed Ground Bar
© 2004 Schneider Electric
All Rights Reserved
6/7/04

21

LOAD CENTERS

S
N

QO® Load Centers
Wiring Diagrams—Single & Three Phase
Class 1130

www.SquareD.com
For the most up-to-date information

1 Phase 3 Wire Main Breaker (Continued)
S/N

LOAD CENTERS

S
N

Main

QO12030M150
QO12030M150C
QO12030M150RB

S
N

Main

S
N

S
N

S
N

Main

S
N

QO124M100
QO124M125
QO124M125RB
QO124M150
QO124M200

S
N

Main

S
N

S
N

QO130M150
QO130M150C
QO130M150RB
QO130M200
QO130M200C
QO130M200RB

Main

S
N

QO132M100
QO132M125
QO132M150

S
N

Main

S
N

S
N

Main

S
N

S
N

Main

S
N

QO13040M200
QO13040M200C

QO140M200
QO140M200C
QO140M200RB
QO140M225

Main
QON42MS300
QON42MS400

QO142M200
QO142M225

QO12040M200
QO12040M200C
QO12040M200RB
QO12040M200TCq

3 Phase 4 Wire Main Lugs
S
N

S
N

S
N

S
N

S
N

S
N

S
N

S
N

S
N

S
N

S
N

S
N

S
N

QO403L60NF/S
QO403L60NRB
QO312L125G
QO312L125GRB
QO320L125G
QO320L125GRB

QO318L200G
QO318L200GRB
QO324L125G
QO330L200G
QO330L200GRB

QO342L225G
QO342L225GRB

3 Phase 4 Wire Main Circuit Breaker
S
N

S
N

S
N

Main

S
N

S
N

Main

S
N

M
a
i
n

QO327M100
QO327M100RB

QO330MQ125
QO330MQ125RB
QO330MQ150
QO330MQ150RB
QO330MQ200
QO330MQ200RB

QO342MQ150
QO342MQ200
QO342MQ200RB
QO342MQ225
QO342MQ225RB

q Includes Factory Installed Ground Bar

22

© 2004 Schneider Electric
All Rights Reserved
6/7/04

HOMELINE® Load Centers
Wiring Diagrams
Class 1170

www.SquareD.com
For the most up-to-date information

1 Phase 3 Wire Main Lugs

S
N

S
N

S/N

S/N

HOM48L125GC
HOM48L125RB

HOM612L100F/S
HOM612L100RB

S
N

S
N

S
N

S
N

S
N

S
N

S
N

S
N

S
N

S
N

G
B

G
B

HOM12L125C
HOM12L125RB
HOM12L200RB
S
N

S
N

S
N

S
N

S
N
S
N

S
N

G
B

HOM2024L125TCq

S
N

S
N

G
B

HOM2040L200TCq

HOM24L125TCq

S
N

S
N

G
B

HOM30L150C
HOM30L200C
HOM30L200RB
HOM30L200TCq

HOM3040L200TCq
HOM40L200C
HOM40L200RB

HOM42L225C

1 Phase 3 Wire Main Breaker
Main

S
N

S
N

G
B

HOM20L125C
HOM20L125RB

HOM1632L200TCFTq

S
N

HOM1624L125C

HOM1224L125TCq
HOM1224L125RB

G
B

HOM1632L200TCq

S
N

S
N

S
N

S
N

G
B

HOM816L125C
HOM816L125RB
HOM816L125TCq

S
N

S
N

S
N

Main

S
N

S
N

Main

S
N

S
N

Main

Main

S
N

S
N

Main

S
N

S
N

G
B

HOM816M100C
HOM816M100RB
HOM816M100TCq

S
N

Main

HOM816M150FTRB
HOM816M200FTRB

S
N

S
N

Main

S
N

Main

S
N

G
B

Main

S
N

S
N

Main

S
N

S
N

Main

HOM1624M225RB
S
N

S
N

Main

S
N

G
B

HOM1632M150TCq
HOM1632M200TCq

S
N

HOM1224M125C

HOM12M100C
HOM12M100RB
S
N

HOM1224M100TCq
HOM1224M125TCq
HOM1224M200TCq

HOM20M100C
HOM20M100RB

S
N

Main

HOM2030M150TCq

S
N

S
N

Main

S
N

HOM2040M200C
HOM2040M200RB
HOM2040M200TCq

HOM24M100C
HOM24M125C
HOM24M125RB

HOM30M100C
HOM30M125C
HOM30M150C
HOM30M150RB
HOM30M200C
HOM30M200RB

Universal Mains
S
N

S
N

S
N

S
N

HOM816U200FTRB
S
N
S
N

S
N

S
N

HOM3040M200RB
HOM3040M200TCq
HOM40M200C
HOM40M200RB
q Includes Factory Installed Ground Bar
© 2004 Schneider Electric
All Rights Reserved
6/7/04

HOM42M200C
HOM42M225C

G
B

HOM1632U200TCq

G
B

G
B

HOM2040U200TCq

HOM3040U200TCq

23

LOAD CENTERS

HOM24L70F/S
HOM24L70RB

Combination
S E R V I C E

E N T R A N C E

D E V I C E

( C S E D )

Flexibility...
Meter-Main CSEDs
Meter main devices are used in residential applications where local codes
require service disconnects to be located outside the dwelling. They include
the utility meter socket and factory installed and/or provisions for field
installation of service disconnect(s) to feed downstream devices. Meter
mains are surface mount and typically used with interior mounted sub-feed
load centers.
All-In-One CSEDs
These devices come with a 30/40 circuit 200 A main circuit breaker load
center and an additional 200 A maximum service disconnect for subfeed
applications. 300 A and 400 A versions are available.

Meter Mains
Square D meter mains include a basic meter socket and single main
service disconnect. Dual main devices are available to feed a second load,
such as a water pump, with a separate service disconnect. Four or six main
disconnect units provide flexibility for feeding additional loads, such as air
conditioning, spa, swimming pool, or garage.
■ Ring or ringless styles meet local utility requirements
■ Fifth jaw and horn bypasses available

24

Combination Service Entrance Devices
Rainproof—Single Phase, Meter-Mains
Class 4119/4120

www.SquareD.com
For the most up-to-date information

Meter-Mains

200 None

OH/UG

RING TYPE

QO®

OH/UG

HOMELINE
QO

OH/UG
OH/UG

245.
681.

22k C2M200S

722.

10k C4L200S

762.

1
1
1
1
2

QOM1-VH
QOM2-VH
QOM2-VH
QO-VH
QO

125
200
200
50
100

.....
.....
....
....
.....

QDL22200a
QDL, QGL, QJLn
QOHe

200 ..... .....
200 ..... .....
200m ..... .....

.....
.....
.....

.....
.....
.....

A-L

(2) Studs #4–250

98, 4

QDL22200a
QDL, QGL, QJLn
QOHe

200 ..... .....
200 ..... .....
200m ..... .....

.....
.....
.....

.....
.....
.....

A-L

(2) Studs #4–250

98, 4

16
.....
16
.....

8
.....
8
.....

200
.....
200
.....

A-L

(2) Studs #4–250

98, 4

A-L

(2) Studs #4–250

98, 4

125d ..... .....
200 ..... .....

.....
.....

.....
.....

A
A–L

#6–2/0
#4–250

#12–4
#12–2/0

31, 24
40, 10

A or B300 #6–2/0
A–L
#4–250
A–L
#4–250

#12–2/0
#12–2/0
#12–2/0

37, 20
47, 10
51, 10

200
200
200
200

8
.....
8
.....

4
6

HOM
HOM

10k SC8L125F
10k SC12L200F
22k SC816F200F g

564.
946.
791.

4
6
1

HOM
HOM
QOM2200VHa

110
200
200

..... .....
..... .....
8 16

.....
.....
8

.....
.....
200

Surface Mount—Supplied with Feed Thru Lugs and provisions for Branch Circuit Breakers
22k SC816F150S g
791.
1
QOM2150VHa
150 None OH/UG
OH/UG
1
HOM2150a
833.
10k SC816D150Cg h
1
HOM
22k SC816F200S g
791.
1
QOM2200VHa
200 None OH/UG
OH/UG
1
HOM2200a
833.
10k SC816D200Cgh
1
HOM

150
150
50
200
200
50

8
8
.....
8
8
.....

8
8
.....
8
8
.....

150
100
.....
200
100
.....

.....

681.
722.
757.
1041.
1255.

.....

25k QU12L400SL l

2540.

1
1
1
6
6
1
1
4

Weight
Each
(Lbs)
and
Pallet
Qty.

.....
.....
.....
.....
.....

564.
946.

RC200S
RC2M200S
22k RC2M200SH
QC12L200Ci
QC12L200CHi jk

Service
Ground
Lug
AWG/
kcmil
(Al/Cu)

.....
.....
.....
.....
.....

QDL22200a
QDL, QGL, QJLn
QDL22200a
QDL, QGL, QJLn

.....
.....
.....
.....
.....

10k SC8L125S
10k SC12L200S

Semiflush Mount only
125 None OH/UG
OH/UG
None OHf/UG OHf/UG
200 None
OHf/UG OHf/UG

Surface Mount Only
None
None
200 Horn OH/UG
None
Horn
Class
400 320
UG
Lever

RINGLESS

10k C125RB
22k CM200S

Surface Mount, convertible to Semiflush with FK400 flange kit (order separately)
1
400 None
UG
UG
25k CU12L400CN b
2540.
1
4
Class
1
400 320
UG
UG
25k CU12L400CB b
2657.
1
Manual
4
Bypass
1
400 None
UG
UG
25k CU816D400CNgb
2650.
1
1
Class
1
320
UG
UG
25k CU816D400CBgb
2767.
400 Manual
Bypass
Surface Mount only
125 None OH/UG
200 None OH/UG

HOMELINE

...
...
...
...
...

Type (Order
Am2-pole
from pere
Circuits Separately
page
27
Rating
(Max.) except as noted) (Max.)

Line
Side
Main
Lugs
AWG/
kcmil
(Al/Cu)

QOM2-VH
QOM2-VH
QO-VH
QO-VH
QO-VH
QDL22200a
QDL, QGL, QJLn
QOHe

200
200
50
200
200
200
200
200m

Surface Mount Only, Supplied with Feed Thru Lugs and provisions for Branch Circuit Breakers
100 Horn OH/UG
.....
22k QC816F100CHgijk
904.
1
QOM2100VHa
OH/UG
.....
22k QC816F125Cgi
869.
1
QOM2125VHa
125 None
Horn OH/UG
.....
22k QC816F125CHgij
904.
1
QOM2125VHa
OH/UG
.....
22k QC816F150Cgi
869.
1
QOM2150VHa
150 None
Horn OH/UG
.....
22k QC816F150CHgij
904.
1
QOM2150VHa
None
OH/UG
.....
22k
QC816F200Cgi
904.
1
QOM2200VHa
200 Horn OH/UG
.....
22k QC816F200CHgij
904.
1
QOM2200VHa
Class
1
QDL22200a
400 320
UG
.....
25k QU816D400SLg
2710.
1
QDL, QGL, QJLn
Lever

16
16
.....
16
16
.....

B
A

#4–1/0
#4–250

#8–1/0
(2) #8–2/0

15, 54
26, 24

A

#4–250

(2) #8–2/0

27, 20

A

#4–250

(2) #8–2/0

27, 28

A–L

#4–250

#12–2/0

40, 10

A or A–L

#6–300

#12–1/0

48, 18

A–L

#4–250

#12–2/0

40, 10

A or A–L

#6–300

#12–1/0

48, 18

#6–350
#6–350
#6–350
#6–350
#6–350

(2)#8–2/0
(2)#8–2/0
(2)#8–2/0
#12–2/0
#12–2/0

26, 24
27, 20
27, 20
40, 21
40, 21

..... .....

.....

.....

A
A
A
A
A

..... .....
..... .....
..... .....

.....
.....
.....

.....
.....
.....

A-L

100
125
125
150
150
200
200
200
200

8
8
8
8
8
8
8
8
8

16
16
16
16
16
16
16
16
16

8
8
8
8
8
8
8
8
8

100
100
100
150
150
200
200
200
200

.....
.....
.....
8
.....

(2) Studs #4–250

98, 4

#6–350

#12–2/0

40, 21

A-L

(2) Studs #4–250

98, 4

A

Surface Mount, convertible to Semiflush with FK400 flange kit (order separately)
1
400 Class
UG
UG
25k QU12L400CL lc
2540.
1
4
320
Lever
1
400
UG
UG
25k QU816D400CL lcg
2710.
1

QDL22200a
QDL, QGL, QJLn
QOHe
QDL22200a
QDL, QGL, QJLn

200
200
200m
200
200

.....
.....
.....
16
.....

.....
.....
.....
8
.....

.....
.....
.....
200
.....

A-L

(2) Studs #4–250

98, 4

A-L

(2) Studs #4–250

98, 4

Surface Mount Only
125 None OH/UG
200 None OH/UG
200 Horn OH/UG

HOM
HOM
HOM

125d ..... .....
200 ..... .....
200 ..... .....

.....
.....
.....

.....
.....
.....

A
A
A

#6–2/0
#6–350
#6–350

#12–4
#12–2/0
#12–2/0

27, 32
40, 21
40, 21

8
8
8
8
8
8
8
...

100
100
150
150
200
200
100
...

A

#6–350

#12–2/0

40, 21

A or B300 #6–300

#6–1/0

48, 18

.....
.....
.....

10k RC8L125S
10k RC12L200Ci
10k RC12L200CHijk

564.
946.
946.

4
6
6

Surface Mount Only, Supplied with Feed Thru Lugs and provisions for Branch Circuit Breakers
100 Horn OH/UG
.....
22k RC816F100CHgij
818.
1
QOM2100VHa
125 Horn OH/UG
.....
22k RC816F125CHgij
818.
1
QOM2125VHa
None
OH/UG
.....
22k
RC816F150Cgi
791.
1
QOM2150VHa
150 Horn OH/UG
.....
22k RC816F150CHgij
818.
1
QOM2150VHa
OH/UG
.....
22k RC816F200Cgi
818.
1
QOM2200VHa
200 None
Horn OH/UG
.....
22k RC816F200CHgij
818.
1
QOM2200VHa
1
HOM2200 a
200 Horn OH/UG
.....
10k RC816D200CHcghj
861.
1
HOM

a Service disconnect supplied factory-installed.
b For use only on 120/240 Vac, 1-Phase, 3-Wire system. (4-jaw meter socket.)
c Knockout provided in cover for use with barrel lock kit, order catalog number SCBRLLOCK
(see Accessories page 27).
d 125 A HOMELINE® 2-pole circuit breaker can be installed in top position only. All other
positions are limited to 100 A max.
e UL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker
installed.
© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE3A

f
g
h
i
j
k
l
m
n

100
125
150
150
200
200
200
50

8
8
8
8
8
8
8
...

16
16
16
16
16
16
16
...

Suitable for OH service with addition of tunnel kit (SCTK20). Order separately.
Supplied with load side feed thru lugs, for #6 AWG–250 kcmil (Al/Cu) conductors.
Convertible to semiflush with SC200F flange kit (order separately).
Device supplied with barrel lock provisions factory-installed.
Supplied with horn bypass and 5th jaw factory-installed.
Not stocked in PDS, contact Lexington for delivery.
5th jaw factory-installed.
QO panel is rated 200 A maximum.
Circuit breaker prefix QBL at 10 kAIR may be used. For complete circuit breaker catalog
number, see page 29.

Discount
Schedule

25

LOAD CENTERS

Surface Mount only
125 None OH/UG
OH/UG

UL &
EUSERC

Catalog
Number

Ampere
Rating (Max.)

UL

Service Disconnect(s)
List
Price
(DE3A)

Spaces

Service
(Type of Feed)

Load Center and Branch
Circuit Breakers
(Order separately
Hub
page 27)
Type
Max. Quantity
(Order
separately
1-pole
from
page 27)
Tandems
Circuits

Bypass
Type

Short Circuit
Current Rating

Ampere
Rating

Meets Federal Spec. W-P-115c as Type 1, Class 2, UL Listed, suitable only for use as service equipment, 120/240 Vac, 1-Phase, 3-Wire, NEMA 3R enclosure

Combination Service Entrance Devices
Rainproof—Single Phase, All-In-Ones
Class 4120

www.SquareD.com
For the most up-to-date information

All-In-Ones

Catalog
Number

Max. Quantity

2-pole
Circuits
(Max.)

Type
(Factory
Installed)

Ampere
Rating
(Max.)

1-pole
Tandems

Hub Type (Order
Separately page 27)

Service Disconnect(s)
List
Price
(DE3A)

Ampere
Rating (Max.)

Load Center & Branch
Circuit Breakers
(Order separately
page 27)

Circuits

Service
(Type
of Feed)
UL &
EUSERC

• Semiflush-REVERSE design available, supplied with load center
(indoor access)
• Supplied with 100% branch neutrals, all unused terminals may be
used for equipment grounding wires.
• Meets Federal Specification W-P-115c as Type 1, Class 2

Spaces

LOAD CENTERS

Bypass
Type

Short Circuit
Current Rating

Ring or ringless type meter socket designs available
UL Listed, suitable only for use as service equipment
Meets EUSERC standards
Service disconnect(s) are supplied factory-installed,
except where noted

Ampere
Rating

•
•
•
•

Line
Side
Main
Lugs
AWG/
kcmil
(Al/Cu)

Service
Ground
Lug
AWG/
kcmil
(Al/Cu)

Weight
Each
(Lbs)
and
Pallet
Qty.

A

#6–2/0

#12–4

32, 24

Surface Mount only
100

None

OH/UG

10k

SC1624M100S

$ 496.

1

HOM2100

100

16 24

8

100

125

None

OH/UG

10k

SC1624M125S

1012.

1

HOM2125

125

16 24

8

125a

200

None

OH/UG

22k

SC2040M200S

1114.

1

QOM2200VH

200

20 40

20

200

A-L

#4–250

#12–2/0

45, 10

200

None

OH/UG

10k

SC2040M200C b

1199.

1

HOM2200

200

20 40

20

100

A or
A-L

#6–300

#12–1/0

47, 18

A or
B300

#6–2/0

#12–2/0

44, 20

A-L

#4–250

#12–2/0

Semiflush Mount only
100

RING TYPE

HOMELINE

125

None
None

200

None

225

None

OH/UG

10k

SC1624M100F

$ 496.

1

HOM2100

100

16 24

8

100

OH/UG

10k

SC1624M125F

1012.

1

HOM2125

125

16 24

8

110

OHc/UG

22k

OHc/UG
OHd/UG

22k

SC2040M125F

1114.

1

QOM2125VH

125

20 40

20

110

SC2040M200F

1114.

1

QOM2200VH

200

20 40

20

200

SC3040M200F

1376.

1

QOM2200VH

200

30 40

10

200

22k

SC3040M225F

1520.

1

QOM2225VH

225

30 40

10

200

51, 10
56, 10

Surface Mount only
100

None

OHh

10k

SO1020M100S

$ 295.

1

HOM2100

100

10 20

10

80

A

#6–1

#14–4

200

None

OHh

22k

SO2040M200S

774.

1

QOM2200VH

200

20 40

20

200

A

#6–350

#8–2/0

43, 21

200

None

OH/UG

22k

SC3040M200S

1340.

1

QOM2200VH

200

30 40

10

200

#4–250

#12–2/0

50, 10

SC40M200S

1621.

1

QOM2200VH

200

40 40

0

200

#4–250

#12–2/0

52, 10

A-L

20, 42

REVERSE All-In-One - Semiflush Mount with Service Disconnect (outdoor access) and Load Center (indoor access)
200

None

UG

10k

SU3040M200R

$1482.

1

QOM2200VH

200

225

None

UG

10k

SU3040M225R

1764.

1

QOM2225VH

225

30 40

10

200

A or
B300

#6–300

#12–1/0

60, 15

A-L

(2) Studs

#4–250

100, 4

A-L

(2) Studs

#4–250

100, 4

A-L

(2) Studs

#4–250

100, 4

A

#6–2/0

#12–4

32, 24

A

#6–350

#12–2/0

40, 21

A-L

(2) Studs

#4–250

100, 6

A

#6–350

#12–1/0

40, 21

Surface Mount, convertible to Semiflush with FK400 flange kit (order separately)
300

Class 320
Manual
Bypass

UG

25k

SU3040D300CBfg

4400.

400

None

UG

25k

SU3040D400CNfg

4700.

400

Class 320
Manual
Bypass

UG

25k

SU3040D400CBfg

4778.

1

QDL22200

200

30 40

10

200

1

QDL, QGL, QJLle

100

..... .....

.....

.....

1

QDL22200

200

30 40

10

200

1

QDL, QGL, QJLle

200

..... .....

.....

.....

1

QDL22200

200

30 40

10

200

1

QDL, QGL, QJLle

200

..... .....

.....

.....

HOM2100

100

HOM2125

125

16 24

8

Surface Mount Only
100
125

HOMELINE

RINGLESS

125
150
200

RC1624M100S

496.

RC1624M125S

1012.

22k

RC2040M125CHij

1067.

1

QOM2125VH

125

20 40

20

100

None

OH/UGh

10k

Horn

OH/UGh

1

100
125a

Horn

OH/UGh

22k

RC2040M150CHij

1142.

1

QOM2150VH

150

20 40

20

150

None

OH/UGh

22k

RC2040M200Ci

1142.

1

QOM2200VH

200

20 40

20

200

Horn

OH/UGh

22k

RC2040M200CHij

1142.

1

QOM2200VH

200

20 40

20

200

200

All-In-One Surface Mount, convertible to Semiflush with FK400 flange kit (order separately)
400

Class
320
Lever

400

K-4
Bolt-On
None

UG

UG

25k

RU3040D400CLfk

4662.

25k

RU3040D400CKf

4662.

1

QDL22200

200

30 40

10

1

QDL, QGL, QJLle

200

..... .....

.....

.....

1

QDL22200

200

30 40

10

200

1

QDL, QGL, QJLle

200

..... .....

.....

QO

Surface Mount Only
150
200

Horn

OH/UGh

22k

QC2442M150CHij

1270.

1

QOM2150VH

150

24 42

18

150

None

OH/UGh

22k

QC2442M200Ci

1270.

1

QOM2200VH

200

24 42

18

200

Horn

OH/UGh

22k

QC2442M200CHij

1270.

1

QOM2200VH

200

24 42

18

200

a 125 A HOMELINE® 2-pole circuit breaker can be installed in top position only. All other
positions are limited to 100 A max.
b Convertible to semiflush with SC200F flange kit (order separately).
c Suitable for OH service with addition of tunnel kit (SCTK20). Order separately.
d Suitable for OH service with addition of tunnel kit (SCTK30). Order separately.
e UL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker
installed.
f Knockout provided in cover for use with barrel lock kit, order catalog number SCBRLLOCK
(see Accessories page 27).

26

DE3A

g
h
i
j
k
l

For use only on 120/240 Vac, 1-Phase, 3-Wire system (4-jaw meter socket).
Device not EUSERC approved.
Device supplied with barrel lock provisions factory-installed.
Supplied with horn bypass and 5th jaw factory-installed.
5th jaw factory-installed.
Additional service disconnect for field-installation, order prefix QBL at 10 kA, QDL at 25 kA,
QGL at 65 kA or QJL at 100 kA. Order separately. For complete circuit breaker catalog
number, see page 29.

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Combination Service Entrance Devices
Circuit Breakers, Accessories, Hubs
Class 4119/4120

www.SquareD.com
For the most up-to-date information

Type: HOM, 1-pole
Type: HOM, 2-pole
Type: QO, 1-pole
Type: QO, 2-pole
Type: QO-VH, 1-pole
Type: QO-VH, 2-pole
Ampere
Rating
Catalog
Price
Catalog
Price
Catalog
Price
Catalog
Price
Catalog
Price
Catalog
Price
a
Number
(DE3D)
Number
(DE3D)
Number
(DE2A)
Number
(DE2A)
Number
(DE2A)
Number
(DE2A)
10
...
...
...
...
QO110
$20.40
...
...
...
...
...
...
15
HOM115
$17.50
...
...
QO115
19.40
...
...
QO115VH
$42.30
...
...
20
HOM120
17.50
...
...
QO120
19.40
...
...
QO120VH
42.30
...
...
25
HOM125
17.50
...
...
QO125
19.40
...
...
QO125VH
48.50
...
...
30
HOM130
17.50
HOM230
$ 40.30
QO130
19.40
QO230
$ 44.70
QO130VH
48.50
QO230VH
$ 97.00
35
...
...
HOM235
40.30
QO135
20.40
QO235
46.90
...
...
...
...
40
HOM140
17.50
HOM240
40.30
QO140
19.40
QO240
44.70
...
...
QO240VH
97.00
45
...
...
HOM245
40.30
QO145
20.40
QO245
46.90
...
...
...
...
50
HOM150
17.50
HOM250
40.30
QO150
19.40
QO250
44.70
...
...
QO250VH
97.00
60
...
...
HOM260
40.30
QO160
20.40
QO260
44.70
...
...
QO260VH
97.00
70
...
...
HOM270
82.00
QO170
46.90
QO270
89.00
...
...
QO270VH
149.00
80
...
...
HOM280
112.00
...
...
QO280
126.00
...
...
QO280VH
210.00
90
...
...
HOM290
112.00
...
...
QO290
126.00
...
...
QO290VH
210.00
100
...
...
HOM2100
112.00
...
...
QO2100
126.00
...
...
QO2100VH
210.00
110
...
...
HOM2110
258.00
...
...
QO2110
285.00
...
...
QO2110VH
689.00
125
...
...
HOM2125
246.00
...
...
QO2125
285.00
...
...
QO2125VH
689.00
150
...
...
HOM2150BB
285.00
...
...
QO2150
327.00
...
...
QO2150VH
707.00
175
...
...
HOM2175BB
285.00
...
...
QO2175
327.00
...
...
QO2175VH
707.00
200
...
...
HOM2200BB
285.00
...
...
QO2200
327.00
...
...
QO2200VH
707.00
Ampere
Type: QOM1-VH, 2-pole
Type: QOM2-VH, 2-pole
Type: QDL, 2-polec
Rating
Catalog Number
Price (DE3A)
Catalog Number
Price (DE3A)
Catalog Number
Price (DE2A)
a
50
QOM50VHb
$ 93.00
...
...
...
...
60
QOM60VH
93.00
...
...
...
...
70
QOM70VH
93.00
...
...
QDL22070
$762.00
80
QOM80VH
134.00
...
...
QDL22080
762.00
90
QOM90VH
134.00
...
...
QDL22090
762.00
100
QOM100VH
134.00
QOM2100VH
$312.00
QDL22100
762.00
110
QOM110VH
312.00
...
...
QDL22110
762.00
125
QOM125VH
312.00
QOM2125VH
312.00
QDL22125
762.00
150
...
...
QOM2150VH
312.00
QDL22150
762.00
175
...
...
QOM2175VH
312.00
QDL22175
762.00
200
...
...
QOM2200VH
312.00
QDL22200
762.00
225
...
...
QOM2225VH
312.00
...
...
a Do not exceed mains rating of device
b Reference National Electrical Code Article 230-79.
c For additional interrupting rating circuit breakers, order circuit breaker prefix QBL at 10 kA, QGL at 65 kA or QJL at 100 kA, see page 29.

Accessories

Accessories
Catalog
Number

Description
Generator Kit: Interlocks main service disconnect and
generator circuit breaker (order separately). For use on:
HOMELINE® CSED Devices
RC816F-, RC2040M-, SO2040MQO CSED Devices
QC816F-, QC2442MFifth Jaw Kit for:
Meter Main Types: C, RC, SC, QC
All-In-One Types: SC, SU (100–225 A), QC, RC, SO
Bypass (Horn Type) for:
Ringless Type Meter Mains and All-In-Ones (100–200 A)
Lexan Meter Socket Cover Plate for:
Ring and Ringless Type Meter Mains
Ring and Ringless Type All-In-Ones
Meter Socket Sealing Rings for Ring Type
Meter Mains and All-In Ones:
Screw Type Aluminum
Snap Type Stainless Steel
Trim Kit for 2" X 6" stud wall, used with:
REVERSE All-In-Ones, SU3040M200R, and
SU3040M225R
Barrel Lock Kit (Barrel Lock not included),
supplied with bracket and mounting screw,
refer to listings for where used.
Semiflush Flange Kit for:
Meter Mains: SC816D150/200C and RC816D200CH
All-In-Ones: SC2040M200C
Semiflush Flange Kit for:
Ring and Ringless Type Meter Mains and
All-In-Ones 400 A)
Ringless Type Utility Cover for use on:
RU3040D400CL, QU12L400CL, and QU816D400CL.
Includes one piece meter socket and pull box cover
with handles and closing plate.
Lug Kit includes (4) lugs, for use with
#2 AWG–600 kcmil Al/Cu conductors. Lugs are for
standard 2-Hole mounting. Meter Main and All-In-One
units supplied with (2) Studs per phase and neutral will
accept one lug per phase and neutral
Overhead Feed Trough: For use on 400 A ring and ringless
type meter mains and All-in-Ones.
3" Conduit Adapter Kit: For use on 400 A ring and ringless
type meter mains and All-in-Ones.

Price

Disc.
Sch.

$163.00 (DE3A)

RCGK2
QCGK3

163.00

5J

12.20 (DE3A)

RCHB2

61.00 (DE3A)

29007

6.70 (DE4)

29008W
ARP00026 d

13.40 (DE4)
11.70

SU2X6TRIM

177.00 (DE3A)

SCBRLLOCK

35.30 (DE3A)

SC200F

21.20 (DE3A)

FK400

131.00 (DE3A)

R400L

177.00 (DE3A)

CMELK4d

OCK400

91.00 (DE4)

378.00 (DE3A)

SU400PVCHA3

8.80 (DE3A)

d Order only. Not stocked in PDS. Order Point: Lexington.

Catalog
Number

Description
Touch-Up Paint
(ASA49 Gray)
Ground Bar Kit
Meter Mains and All-In-Ones
QC, RC, and SC (100–225 A)
Filler Plate for:
Meter Main Types: QC, CU
All-In-One Types: QC
Filler Plate for:
Meter Main Types: RC, SC
All-In-One Types: SC, RC, SU
Neutral Lug (#6-2/0) for:
Meter Main Types: RC, SC, QC
All-In-One Types: SC, SU, QC, RC

PK49SP

PK15GTA

Price

Disc.
Sch.

$26.00

(DE1)

11.40 (DE3A)

QOFP

2.40 (DE3A)

HOMFP

2.10 (DE3A)

LK100AN

7.20 (DE3A)

Hubs and Closing Plates
Hub
Conduit Size
Series
(inches)
Closing Plate for “A” Hub opening
1.00
1.25
1.50
A
2.00
2.50
Adapter plate to allow use of “A” Hubs
on “A-L” size hub openings
Closing Plate for “A-L” Hub opening
2.00
2.50
3.00
A-L
3.50
4.00
Closing Plate for “B” Hub opening
0.75
1.00
1.25
B
1.50
2.00
2.50
B300
3.00

Catalog
Number
ACP
A100
A125
A150
A200
A250
AAP
ACPL
A200L e
A250L
A300L
A350L
A400L
BCAP
B075
B100
B125
B150
B200
B250
B300

List
Price
$ 8.90
22.60
22.60
22.60
31.90
40.40

Disc.
Sch.
(DE4)
(DE4)
(DE4)
(DE4)
(DE4)
(DE4)

22.50

(DE4)

12.20
55.00
58.00
74.00
76.00
79.00
2.50
22.20
22.20
22.20
22.20
40.90
68.00
124.00

(DE4)
(DE4)
(DE4)
(DE4)
(DE4)
(DE4)
(DE1A)
(DE1A)
(DE1A)
(DE1A)
(DE1A)
(DE1A)
(DE1A)
(DE1A)

e Supplied with AAP adapter plate and “A” hub.

© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE1

DE1A

DE2A

DE3A

DE3D

DE4

Discount
Schedule

27

LOAD CENTERS

Circuit Breakers
For use with Meter Mains and All-In-One devices

Combination Service Entrance Devices
Dimensions
Class 4119, 4120

www.SquareD.com
For the most up-to-date information
21/2" Max “A” Hub

“A” Hub

“B” Hub

4.60

4.60

4.56

117

117

7.50

116

13.82

19.58

351

Blank End Wall

191

13.46

497

28.25

342

7.44
189

10.70

12.80

718

6.44

8.00

164

203

272

325

18.23

20.79

463

528

A,B

C,D,E,F

41.25

E,F,G,H

A,B

1048

LOAD CENTERS

C,D,E,F

A

C125RB (Shown)
CQRB100

B,C
D,F,G

A,B

Ring Type:
CM200S
C2M200S (Shown)
C4L200S
21/2" Max “A” Hub

Ringless Type:
RC200S
RC2M200S
RC2M200SH
A,B
B,C

C,D,F
A

4.80
122

SO1020M100S

G,H,I,J
“A-L” Hub

4.67

3.39

Surface

A

21/2" Max “A” Hub

119

86

14.77

C,D,F

CU12L400CNc
CU12L400CBc
QU12L400CLc
QU12L400SL

14.37

375

365

14.50
368

B,C

CU816D400CBc
CU816D400CNc
QU816D400CLc
QU816D400SL (Shown)

10.04

10.87

255

276

21/2" Max “A” Hub
D,F,G
B,C
C,D,F

10.87
276

25.12
638

25.12

6.95

35.13

638

176

892

14.50
368

A
2 1/2"

Max
“A” Hub
D,F,G

D,F,G
21/2" Max
“A” Hub or
B300

C,D,F

SC8L125S (Shown)
RC8L125S
SC1624M100S
SC1624M125S
RC1624M100S
RC1624M125S

C,D,F

14.81
376

C,D,E,F

A,B

D,E,F,G

SC8L125F (Shown)
SC1624M100F
SC1624M125F

A,B,C

819

RC816F100CH
RC816F125CH
RC816F150C/CH
RC816F200C/CH
RC12L200C/CH
RC2040M125CH
RC2040M150CH
RC2040M200C/CH

3.40
86

14.62

7.90

371

B,C

201

32.23

C,D,E,F

C,D,E,F
A,B
A

A

A,B

B,C

A,B

A

A,B
B,C

14.85
377

QC816F100CH
QC816F125C/CH
QC816F150C/CH (Shown)
QC816F200C/CH
QC12L200C/CH
QC2442M150CH
QC2442M200C/CH
SO2040M200S

B,C

A
C,E,F,G,H
21/2" Max
“A-L” Hub

A,B

B,C

C,D,E,F

SC816D150Cq (Shown)
SC816D200Cq
SC2040M200Cq
RC816D200CHq

CL
Top
Branch
Circuit
Breaker

31.61
803

27.00
686

21/2" Max “A” Hub

39.60

35.40

7.50

1006

899

Blank End Wall

191

5.80
147

48.00

28.25

1219

718

21.50
546

CL
Meter
Socket

10.30

B

D,F,G

4.40

A
B

3.50

C,D,E,F

SC816F200F
SC12L200F
SC2040M125F
SC2040M200F (Shown)
SC3040M200F
SC3040M225F

35.40

C,D

899

SU3040M200R (Shown)
SU3040M225R

39.60
1006

a Note 1:
Driphood supplied factory-installed
and is required for surface mount
installation.
For semi-flush installation, remove
driphood and install flange kit, catalog
number: SC200F (order separately).

A

112

89

B

B

C,E,F,G,H
21/2" Max
“A-L” Hub

14.97
380

SC40M200S

B,C

SC3040M200S

B,C

“A” Hub or
B300 Hub

8.00

262

282

749

41.25

820

1048

37.30
947

A

C,D,E,F
C,E,F,G,H
21/2" Max
“A-L” Hub

“A” Hub

B,C

A

B

7.14
181

28.28
718

C,D,F

G,H,I,J
“A-L” Hub

SC12L200S
SC816F150S
SC816F200S
SC40M200S
SC2040M200S (Shown)
SC3040M200S

C,D,F

B,C

SU3040D400CBc (Shown)
RU3040D400CLc
SU3040D300CBc
RU3040D400CKc
SU3040D400CNc

Knockouts

B,C,D
A

7.50
191

Semi-Flush End Wall

28

29.50

32.30

Drip Hood

b Note 2:
Unit supplied with blank top endwall (factoryinstalled) for surface mount installation. For
semi-flush installation, install flange kit, catalog
number FK400 (order separately). Kit includes
replacement top endwall (with knockouts) and
flanges.

203

11.10

Symbol

A

B

C

D

E

F

G

H

I

J

Conduit Size
(inches)

1⁄2

3⁄4

1

11⁄4

11⁄2

2

21⁄2

3

31⁄2

4

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Enclosed Molded Case Switches, Enclosed GFCI
Circuit Breakers, Circuit Breaker Enclosures
Class 1131

www.SquareD.com
For the most up-to-date information

Circuit Breaker Enclosures—UL Listed

Enclosed Molded Case Switches—UL Listed

22,000 RMS Symmetrical Ampere Short Circuit Current Rating. Not for use with one pole
QO circuit breakers. Circuit breakers not included. Order QO®, QO-GFI, QO AFI, QO-EPD
and QO-PL circuit breakers separately from pages 3 and 4. Accepts QO circuit breakers
with factory-installed accessories. Order equipment ground bar PK0GTA2, if required.

Molded Case Switch Included. Does not provide overcurrent
protection.
Service

Ampere
Rating

60 ab

General Purpose
Catalog No.

Rainproof

Price

QO260NATS

Catalog No.

$107.00

Box No.
See Page
19, 20

Price

QO200TR

$112.00

Service

General Purpose e

Rainproof

Ampere
Rating

Catalog No.

Price

100
125

QO2100BNF/S
QO2125BNF/S

$55.00
72.00

100

QO3100BNF/S

99.00

2, 9R c

240 Vac

Catalog No.

Price

Box. No.
See Page
19, 20

QO2100BNRB $ 90.00
QO2125BNRB 105.00

13, 10R
18, 13R

QO3100BNRB

13, 10R

100 d

QO2000NS

184.00 QO2000NRB

225.00

13,10R

120/240 Vac

138.00

240 Vac
10,000 RMS Symmetrical Ampere Short Circuit Current Rating.
Circuit breaker not included. Order separately from page 3. Will not accept QO-GFI
circuit breaker nor QO circuit breakers with factory-installed accessories.

Housing Bracket
Description

Catalog No.

Price

Bracket used with QO200TR for stucco, aluminum and vinyl siding.
Order quantity multiples of 10.

PKHB

$2.10

60 a

....

....

QO2TR

$ 63.00

9R c

240 Vac

Enclosed GFCI Circuit Breakers—UL Listed
2-pole, 120/240 Vac, GFCI circuit breaker included, 10,000 AIR
Service

Ampere
Rating

50

Type 3R—Rainproof
Catalog No.

Price

Circuit Breaker
Included

QOE250GFINM
HOME250SPA

$352.
315.

QO250GFI
HOM250GFI

Box. No.
See Page
20
1NM (Non-metallic)
1R (Metallic)

120/240 Vac

QO2000NS

QO3100BNF
With Cover Removed

Q Frame Enclosures and Q Frame Circuit Breakers—UL Listed
Enclosure Only g
Type 1—General Purpose e

Service

Catalog No.

Price

Q22200NS h
or
Q23225NF/S

$117.00
145.00

Circuit Breaker (Order Separately)

Type 3R—Rainproof
Catalog No.

Price

Q22200NRBh $253.00
or
Q23225NRB
278.00

Box No.
See Page
19, 20

19, 11R
20, 12R

2-pole 240 Vac
Maximum

Q23225NF/S

145.00

Q23225NRB

278.00

10,000 AIR

Ampere
Rating

20, 12R

3-pole 240 Vac

Cat. No.

Price

25,000 AIR
Cat. No.

Price

65,000 AIR
Cat. No.

70
80
90
100
110
125
150
175
200
225

QBL22070 $316.
QBL22080
316.
QBL22090
316.
QBL22100
316.
QBL22110
316.
QBL22125
316.
QBL22150
316.
QBL22175
316.
QBL22200
316.
QBL22225
316.

QDL22070 $ 762. QGL22070 $1014.
QDL22080
762. QGL22080 1014.
QDL22090
762. QGL22090 1014.
QDL22100
762. QGL22100 1014.
QDL22110
762. QGL22110 1014.
QDL22125
762. QGL22125 1014.
QDL22150
762. QGL22150 1014.
QDL22175
762. QGL22175 1014.
QDL22200
762. QGL22200 1014.
QDL22225
762. QGL22225 1014.

70
80
90
100
110
125
150
175
200
225

QBL32070
QBL32080
QBL32090
QBL32100
QBL32110
QBL32125
QBL32150
QBL32175
QBL32200
QBL32225

QDL32070
QDL32080
QDL32090
QDL32100
QDL32110
QDL32125
QDL32150
QDL32175
QDL32200
QDL32225

832.
832.
832.
832.
832.
832.
832.
832.
832.
832.

1189.
1189.
1189.
1189.
1189.
1189.
1189.
1189.
1189.
1189.

QGL32070
QGL32080
QGL32090
QGL32100
QGL32110
QGL32125
QGL32150
QGL32175
QGL32200
QGL32225

100,000 AIR

Price

1628.
1628.
1628.
1628.
1628.
1628.
1628.
1628.
1628.
1628.

Cat. No.

Price

QJL22070
QJL22080
QJL22090
QJL22100
QJL22110
QJL22125
QJL22150
QJL22175
QJL22200
QJL22225

$1260.
1260.
1260.
1260.
1260.
1260.
1260.
1260.
1260.
1260.

QJL32070j
QJL32080j
QJL32090j
QJL32100j
QJL32110j
QJL32125j
QJL32150j
QJL32175j
QJL32200j
QJL32225j

1864.
1864.
1864.
1864.
1864.
1864.
1864.
1864.
1864.
1864.

QOM2 Enclosures and QOM2 Circuit Breakers—UL Listed
QOM2 Circuit Breaker
(Order Separately) i

Enclosure Onlyf
Type 1
General Purposee

Type 3R
Rainproof
Price

Box No.
See
Pages
19, 20

Ampere
Rating

Service

Catalog No.

QOM22225NF/S $156. QOM22225NRB $293.

22, 16R

100
125
150
175
200
225

QOM2100VH $312.
QOM2125VH 312.
QOM2150VH 312.
QOM2175VH 312.
QOM2200VH 312.
QOM2225VH 312.

Catalog No.

Price

Catalog No.

2-pole 240 Vac
Maximum

22,000 AIR

a
b
c
d
e
f
g

Price
r

Not suitable for service equipment.
Maximum 10 hp 240 Vac.
Top endwall has no hub opening.
Maximum 20 hp 240 Vac.
Order F for flush, S for surface.
Equipment ground bar kit PKOGTA2 factory-included.
Factory-installed groundable neutral assembly includes (2) ground lugs and (2) neutral lugs.
Equipment ground kit PKOGTA2 also included.
h Accepts 200 A max. 2-pole Q Frame circuit breakers.
i Add suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126.
j When these 3-pole circuit breakers are mounted in an enclosure, the maximum AIR rating is 65,000 at 240 Vac and
100,000 at 208 Vac.
© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE2A

rDE3A

QOM22225NS
Q22200NS
With Cover
With Cover Removed
Removed
(Order Q Frame circuit breaker separately)

Discount
Schedule

Q23225NF

29

LOAD CENTERS

120/240 Vac

Surge
P R O T E C T I O N

Surgebreaker® secondary surge arresters
The Surgebreaker secondary surge arrester is available for both
QO® and Homeline® load centers. These surge arresters plug onto the
load center bus bars like a circuit breaker and provide protection from high
voltage surges. The Homeline Surgebreaker surge arrester can be used in
Square D All-In-Ones and Meter Mains.

Surgebreaker Plus Whole House
Surge Protector
The Surgebreaker Plus Whole House Surge Protector from
Square D is ideal for protecting electrical circuits, multiple telephone lines
and multiple TV lines in today’s electronic home.
■ UL listed 1449, 2nd edition.
■ $50,000 Warranty.
■ Suitable for use in service entrance locations: meets requirements of

NEC Article 280.
■ Suitable for indoor applications only.
■ LED Status Indicator.
■ Flush or surface mounting.
■ Electrical System - Connects through the main load center.
■ Two coax lines - Master antenna, satellite dish or cable.
■ Four line telephone (Digital/Analog POTS) protection.

30

Surge Protective Devices
TVSS and Surge Arresters
Class 6671

www.SquareD.com
For the most up-to-date information

SURGEBREAKER® PLUS
Transient Voltage Surge Suppressor

•
•
•
•
•
•
•

QO2175SB

AC line protection
Four line telephone (Digital/Analog POTS) protection
Two line coaxial protection
Suitable for indoor applications only
Flush or surface mounting
LED status indicator
Modular design

Single Phase Three Wire—120/240 Vac
Description

Catalog
Number

Price

SURGEBREAKER PLUS

SDSB1175C

$420.

SURGEBREAKER
Secondary Surge Arrester
SDSB1175C

Suitable for use in service entrance locations; meets
requirements of NEC Article 280.

HOM2175SB

•
•
•
•
SDSA1175
SDSA3650

White

•
•

Black
White
Black
Black

One SDSA1175 on
120/240 Vac Circuit

Listed secondary surge arresters;
QO2175SB also CSA Certified
Meet ANSI/IEEE C62.11-1993
QO2175SB for QO® load centers and combination
devices, NQOD panelboards
HOM2175SB for HOMELINE® load centers and
combination devices
Plug-on design requires two pole spaces
LED indicates operational status
Catalog
Number

Price

QO SURGEBREAKER
CULUS Listed Secondary Surge Arrester
150 Vac line-to-ground maximum.

QO2175SB

$106.

HOMELINE SURGEBREAKER
CULUS Listed Secondary Surge Arrester
150 Vac line-to-ground maximum.

HOM2175SB

Description

Black

Black

CULUS

3Ø4W
208Y/120 Vac
480Y/277 Vac
600Y/347 Vac

106.

Hard-Wired Secondary Surge Arrester
Suitable for use in service entrance locations; meets
requirements of NEC Article 280.
Black

White
Black

CULUS Listed and CSA Certified secondary surge
arresters
• Meet ANSI/IEEE C62.11-1993
• Suitable for indoor and outdoor applications
• LED indicates operational status

•

White
Black

Black
Black

Black
White

Two SDSA1175 on
208Y/120 Vac Circuit

3Ø4W
240/120 Vac

Black

Price

SECONDARY SURGE ARRESTER
For 1Ø3W systems.
150 Vac phase-to-ground maximum.

SDSA1175 a

$ 61.

SECONDARY SURGE ARRESTER
For 3Ø systems.
600 Vac phase-to-ground maximum.b

SDSA3650

White

3Ø3W
Grounded B Phase)
240 Vac
480 Vac

DE1B

165.

a See page 13 for QOSAMK mounting kit for installation in QO load centers.
b Do not use on ungrounded systems. Systems must be solidly grounded.

Black

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Catalog
Number

Description

Black

For additional information, reference Catalog #6671CT9701R2/02.

Discount
Schedule

31

LOAD CENTERS

Suitable for use in service entrance locations; meets
requirements of NEC® Article 280, UL Listed 1449, 2nd
Edition, and meets ANSI/IEEE C62.41-1991.

Air Conditioning
D I S C O N N E C T

Air Conditioning Disconnects
No air conditioning electrical protection system is complete without a
Square D air conditioning disconnect. Our disconnects are available in
a variety of configurations that let you choose the best product for your
particular application. These include molded case switch, fused, and
non-fused switches.

Enclosed Molded Case Switch
■ Cover housing can be removed to provide open access to lugs for

easy wiring.
■ 60 A switch rated for 10 hp motors at 240 Vac.
■ Factory installed ground bar is located in front for easy access.
■ Open area for mounting allows plenty of room for power actuated tool.

Dimples accommodate nailer.

Fusible and Not Fusible Pullout Switches
■ Interior trim cannot be removed unless the pull-out head is completely

disengaged or placed in the OFF position.
■ Pull-out head can be replaced in the OFF position.
■ 30 A and 60 A fusible, and 60 A not fusible ratings,

up to 10 hp at 240 Vac.

32

Air Conditioning Disconnects
Class 3150

www.SquareD.com
For the most up-to-date information

Not Fusible Air Conditioning Disconnect—Molded Case Switch
Rainproof—UL Listed
Service

Metallic

Ampere
Rating a

Catalog
Number

Non-metallic
Catalog
Number

Price

QO200TRNM

$127.00

Price

Max. Hp

2 Wire (Molded Case Switch Included)—240 Vac Maximum

QO200TR

QO200TR

$107.00

10

Housing Bracket
Description

Catalog No.

Price

PKHB

$2.10

Bracket used with QO200TR for stucco, aluminum and vinyl siding.
Order quantity multiples of 10.

Not Fusible Air Conditioning Disconnect—Pullout
Rainproof—UL Listed
Service

Metallic

Ampere
Rating a

Non-metallic
Max. Hp

Catalog
Number

Price

Catalog
Number

Price

UFP222R

$113.00

UFP222RNM

$127.00

10

...

...

10

...

...

10

2 Wire—240 Vac Maximum

60
G/B

QO200TRNM

2 Wire—240 Vac Maximum—with 20 A GFI receptacle

60

UFP222RGFI

$303.00

G/B
GFI Rec.

2 Wire—240 Vac Maximum—with 20 A duplex receptacle

60

UFP222RD

$173.00

G/B

PKHB
Housing
Bracket

Duplex Rec.

Fusible Air Conditioning Disconnect—Pullout
Rainproof—UL Listed
Service

Metallic

Ampere
Rating b

Catalog
Number

Non-metallic
Price

Catalog
Number

Price

Max. Hp

2 Wire (Pullout and Fuseholder)—240 Vac Maximum

G/B

30

FP221R

$107.00

FP221RNM

$127.00

3

60

FP222R

107.00

FP222RNM

127.00

10

Note: Suitable for use as service equipment on 120/240 Vac 1Ø3 wire services if used only on a 1Ø2 wire load; and
only when the equipment grounding terminal is replaced with ground terminal kit catalog number PK3GTA1.
Price $7.60.

Box Dimensions
FP221R

Catalog
Number

H

W

D

IN

mm

IN

mm

IN

mm

QO200TR

4.63

117

6.50

165

3.88

98

QO200TRNM

8.75

222

6.50

165

3.88

98

UFP222R

5.25

133

7.50

191

3.25

83

UFP222RNM

8.75

222

6.50

165

3.88

98

FP221R

5.25

133

7.50

191

3.25

83

FP221RNM

8.75

222

6.50

165

3.88

98

FP222R

5.25

133

8.88

225

3.25

83

FP222RNM

8.75

222

6.50

165

3.88

98

a Does not contain overcurrent protection. Suitable for use on systems with up to 10,000 RMS symmetrical amperes
available fault current at 240 Vac max when protected by a fuse or circuit breaker rated 60 A or less.
b Suitable for use on systems with up to 10,000 RMS symmetrical amperes available fault current at 240 Vac.

© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE2A

Discount
Schedule

33

LOAD CENTERS

60
G/B

SERVICEPAK® Power Outlet Panels
Class 1140

www.SquareD.com
For the most up-to-date information

LOAD CENTERS

For Construction Sites
• Provide temporary power at construction sites.
• Each receptacle protected by QO-GFI circuit breaker in compliance with NEC®
requirements.
• Each enclosure is rainproof.
• 10,000 RMS symmetrical ampere short circuit current rating.
• UL Listed as suitable for use as temporary site service equipment.
• Provided with neutral bonding provisions.
• Boxes have provisions for type “B’’ hubs to be field-installed.
Power
Outlet
Configuration

Service
a

Mains
Ampere
Rating

1C
2C
2C

1Ø2W
1Ø2W
1Ø2W

40
40
40

3C

1Ø3W

70

4C

1Ø3W

70

5C

1Ø3W

70

6C

1Ø3W

70

7C

1Ø3W

70

8C

1Ø3W

70

9C

1Ø3W

100

Circuit Breaker
(Included)
(1) QO120GFI
(2) QO120GFI
(2) QO120GFI
(1) QO120GFI
(1) QO230GFI
(1) QO120GFI
(1) QO220GFI
(1) QO120GFI
(1) QO250GFI
(1) QO120GFI
(1) QO250GFI
(2) QO120GFI
(1) QO220GFI
(2) QO120GFI
(1) QO250GFI
(1) QO120GFI
(2) QO250GFI

Receptacles
(Included) b
A C D E F
1
2
2
1

1

T

1C
T

Main Wire Size
AWG d
Cu
Al
$294. #14–6 #12–6
545. #14–6 #12–6
545. #14–6 #12–6

Catalog
Number
c

T

T

T

T

1

1

1

1

1

2

1

T

PAK31CGFI

649.

#8–1

#8–1

649.

#8–1

#8–1

PAK51CGFI

649.

#8–1

#8–1

T

10C

PAK55CGFI

649.

#8–1

#8–1

882.

#8–1

#8–1

882.

#8–1

#8–1

2

1

PAK76CGFI

1

2

PAK1004CGFI

1054.

T

T

T

T

T

8C
T

T

T

9C
T

T

11C

T

T

6C

T

PAK36C1GFI

PAK72CGFI

3C

5C

7C
1

T

2C

4C

Price

PAK10C1
PAK11C e
PAK11C1

T

T

T

12C

T

#14–1 #12–1

13C

14C

For Recreational Vehicle Parks
•
•
•
•
•

Provide electrical power to individual recreational vehicle park sites.
Each receptacle protected by appropriate GFI or Standard QO® circuit breaker.
All receptacles and circuit breakers included.
10,000 RMS Symmetrical Ampere short circuit current rating.
• UL Listed.
All enclosures are rainproof. • No neutral bonding provisions. • Loop-feed provisions.

Mains
Power Outlet Service Ampere
Configuration
a
Rating

Circuit Breaker
(Included)

Receptacles
(Included) b
A

B

Catalog
Number

Price

C

Main Wire Size
AWG/kcmil f
Phase and Neutral
Cu
Al

Underground or Overhead Loop-Feed Terminals—Non-Pedestal cg
10C
11C

1Ø2W
1Ø2W

40
40

12C

1Ø2W

50

13C

1Ø2W

75

14C

1Ø3W

100

(1) QO120GFI
(2) QO120GFI
(1) QO120GFI
(1) QO130
(1) QO120GFI
(2) QO130
(1) QO120GFI
(1) QO250
(1) QO130

1
2

PAK10CTG
PAK11CTG

$313.
530.

1

1

PAK41CTG h

376.

1

2

PAK61CTG h

435.

1

1

PAK75CTG
(Not Loop Feed) h

446.

1

#14–6

#14–1

a
b
c
d
e
f
g
h
i
j

1Ø2W

40

12C

1Ø2W

50

13C

1Ø2W

75

14C

1Ø3W

100

(2) QO120GFI
(1) QO120GFI
(1) QO130
(1) QO120GFI
(2) QO130
(1) QO120GFI
(1) QO250
(1) QO130

2

PAK11PG

#12–1

$690.

1

1

PAK41PG h

568.

1

2

PAK61PG h

609. (2)#6–250 (2)#6–250

1

1

PAK75PG h

671.

1

20 Amp 125 Volt 2W and Grd.
NEMA 5-20R

B

30 Amp 125 Volt 2W and Grd.
ANSI #73.13

C

50 Amp 125/250 Volt 3W and Grd.
NEMA 14-50R

D

20 Amp 250 Volt 2W and Grd.
NEMA 6-20R

E

30 Amp 125/250 Volt 3W and Grd.
NEMA 14-30R

F

50 Amp 250 Volt 2W and Grd.
NEMA 6-50R

#12–6

Pedestal Mounted—Underground Loop-Feed Terminals ij
11C

A

All non-pedestal devices have provisions to
field-install a Type “B’’ hub on the bottom
endwall for bottom feed from a conduit riser.
Order Type “B’’ bolt-on hub (B250 Max.) and
two mounting screws (Part No. 8002505501)
and two hex nuts (Part No. 2340102000).

(1Ø2W 120 Vac) (1Ø3W 120/240 Vac)
20 ampere receptacles protected by 20 ampere GFI circuit breaker.
Devices have a bolt-on factory-installed closing cap. Order type "B’’ bolt-on hub separately from page 20.
Equipment Ground Terminal suitable for (2) #14 or 12 AWG Cu or (2) #12 or 10 AWG Al.
Receptacles in this device are in bottom endwall and are accessible with outer door padlocked.
"Order Only’’ from Lexington—Minimum order quantity is 50 devices.
Two wires each per phase, neutral, and equipment ground—for loop feed (except PAK75CTG).
Equipment ground terminal suitable for (2) #14–12 AWG Cu or (2) #12–10 Al.
GFI circuit breaker can be substituted for standard 30 A circuit breaker. For 30 ampere receptacles add $140.00 per circuit
breaker.
Add suffix "FI’’ to catalog number. Example: PAK41CTGFI.
Stabilizer foot available for use in unstable ground, order catalog number HNPSF $27.50 list.
Equipment ground terminals suitable for (2) #10–2/0 AWG Cu or (2) #6–2/0 AWG Al.

34

DE4

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Structured Wiring
A

N E W

O P P O R T U N I T Y
T O

I N C R E A S E

S A L E S

P E R

Y O U R

H O M E

The Square D Multi-Link Structured Wiring System devices organize the
way a house is wired to coordinate telephone, video, and data
services for unmatched flexibility and convenience. Installed during
construction, these devices increase capabilities without adding
significant cost to the home.
Pre-wiring with standard Cat-5 and RG-6 cables will ensure that the
home is wired to meet the demands of today and the future innovations of
tomorrow. Square D Multi-Link Structured Wiring System provide the
enclosures and brackets to install the video, voice, audio and data hubs
along with the accessories and upgrade options to bring the home into
the telecommunication and entertainment future.
Application:

■ Residential and light commercial
■ New multi-family and single-family construction

Standards:

■ UL 1492, Audio/Video Products and Accessories
■ UL 514A, Metallic Outlet Boxes
■ UL 1863, Communications Circuit Accessories
■ Federal Regulation 47CFR15.115
■ TIA/EIA 570-A, Residential Telecommunications
Cabling Standard

Enclosures:

■ NEMA Type 1
■ Surface or flush mount

Construction:

■ Modules mount on enclosure grid via “hook and
swing” method
■ All modules incorporate a metal backplate for
strength and rigidity
■ Data and telephone modules available with either
110 punch down terminations or RJ-45 modular plugs

Accessories:

AC power accessories, universal adapter brackets, patch
cords, cover lock kit, video attenuators, low pass filters.

35

Square D Multi-Link Structured Wiring System
Class 1400

www.SquareD.com
For the most up-to-date information

The Square D Multi-Link Structured Wiring System devices organize the way a house is
wired to coordinate telephone, video, and data services for unmatched flexibility and
convenience. Installed during construction, these devices increase capabilities without
adding significant cost to the home.
System Components
Description

Catalog
Number

Price

Grid
Mounting
Space (IN)

Standard
Package

10

LOAD CENTERS

Mounting Brackets and Enclosures
Surface mounting bracket, 6 1/2"w x 10"h, white

SDM10BW

15.20

10

Cover for SDM10BW, white

SDM10CW

$

28.60

...

1

Enclosure w/mounting grid, 14"w x 18"h, white

SDM18BW

44.60

34a

1

Cover for SDM18BW, white

SDM18CW

16.30

...

1

Enclosure w/mounting grid, 14"w x 36"h, white

SDM36BW

86.00

70b

1

Cover for SDM36BW, white

SDM36CW

28.00

...

1

Combo hub, video splitter (1 input x 4 TVs) / phone
(2 lines x 6 phones), grid mount

SDM26P14V

58.00

3

1

Combo hub, video splitter (1 input x 4 TVs) / phone
(4 lines x 6 phones), grid mount

SDM46P14V

77.00

3

1

SDM46P

Combination Video/Telephone Hubs

SDM18CW and SDM18BW

Telephone Hubs
Telephone master hub, 4 lines x 6 phones, grid mount

58.00

3

1

Telephone expansion hub, 4 lines x 8 phones, grid mount SDM48PX

58.00

3

1

Telephone interface hub, 4 lines x 11 phones, grid mount,
RJ45 jacks

SDM412PJ

74.00

3

1

Video splitter, (1 input x 3 TVs), grid mount

SDM13VS

19.10

2

1

Video splitter, (1 input x 4 TVs), grid mount

SDM14VS

22.90

2

1

Video splitter, (1 input x 8 TVs), grid mount

SDM18VS

42.00

2

1

Video amplifier hub (1 input x 6 TVs), bi-directional CATV
or antenna, grid mount, 120 Vac power supply included

SDM16VAB

96.00

3

1

Video amplifier hub (3 inputs x 8 TVs), bi-directional
CATV, IR repeating system, grid mount, 120 Vac power
supply included

SDM38VBIR

286.00

2.5

1

Video amplifier hub (3 inputs x 8 TVs), CATV or antenna,
IR repeating system, grid mount, 120 Vac power supply
included

SDM38VHIR

286.00

2.5

1

Single channel modulator, RCA inputs, grid mount, 120
Vac power supply included

SDM11VM

248.00

2.5

1

Single channel combination modulator, amplifier. Cat-5
input for modulation, combined with amplified coax input
for bi-directional CATV, grid mount, 120 Vac power supply
included

SDM11VMB

286.00

2.5

1

Single channel combination modulator, amplifier. Cat-5
input for modulation, combined with amplified coax input
for CATV or antenna, grid mount, 120 Vac power supply
included

SDM11VMH

286.00

2.5

1

Set top mount dual channel modulator, RCA inputs, IR
repeating system, 120 Vac power supply included

SDM21VT

372.00

...

1

Set top mount quad channel modulator, RCA inputs, IR
repeating system, 120 Vac power supply included

SDM41VT

563.00

...

1

Set top mount dual channel MTS stereo modulator, RCA
inputs, IR repeating system, 120 Vac power supply
included

SDM21VTST

667.00

...

1

Set top mount quad channel MTS stereo modulator, RCA
inputs, IR repeating system, 120 Vac power supply
included

SDM41VTST

1122.00

...

1

Modulator combiner hub (8 input x 1 output), grid mount,
use with Video Hub SDM38VHIR/SDM38VBIR, 120 Vac
power supply included

SDM81VC

172.00

2.5

1

Cat-5 Video Wall Plate, use with SDM11VMB/
SDM11VMH if modulating from a source with RCA
outputs

SDM1VWP

67.00

...

1

133.00

2.5

1

63.00

3

1

Video Hubs

SDM46P14V

Modulators

SDM46P

SDM38VBIR/SDM38VHIR

Satellite Hub
Satellite TV multi-switch, connects 4 satellite receivers to
a dual LNB dish, grid mount

SDM11VMH/SDM11VMB

SDM24VD

Audio Hub
Speaker distributon hub (stereo), distributes 1 audio
source to six rooms, grid mount

SDM16A

a Two columns of grid mounting space, 17" of space per column.
b Two columns of grid mounting space, 35" of space per column.

For additional information, reference Catalog #1400CT0101R3/03.

36

DE7

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

www.SquareD.com

Square D Multi-Link Structured Wiring System
Class 1400

For the most up-to-date information

System Components, continued
Description

Catalog
Number

Price

Grid
Mounting Standard
Space
Package
(IN)

SDM8D

Data termination hub provides termination point for Cat-5
wiring, 100 Base-T certified, 8 bridgeable circuits
SDM8D
(8 - 110 punch down blocks connected to 8 - RJ-45 jacks)

$ 67.00

3

1

Data termination hub provides termination point for Cat-5
wiring, 100 Base-T certified, 16 bridgeable circuits (16 110 punch down blocks connected to 8 - RJ-45 jacks)

SDM8DB

87.00

4.5

1

Ethernet hub, 10 Base-T certified, 5 - RJ-45 ports, uplink
port, grid mount, 120 Vac power supply included

SDM5DE

114.00

4

1

Router hub, 10/100 Base-T certified, 7 - RJ-45 ports, grid
mount, integral 120 Vac power supply

SDM7DR

374.00

14a

1

B&W, single gang in-wall, 0.3 lux, fixed aim, used with
and powered by SDM11VMB/SDM11VMH modulator via
Cat-5 wiring

SDM1VC

229.00

...

1

Color, single gang in-wall, 6 lux, fixed aim, used with
and powered by SDM11VMB/SDM11VMH modulator via
Cat-5 wiring

SDM1VCC

457.00

...

1

B&W, double gang in-wall, 2 lux, adjustable aim, used
with and powered by SDM11VMB/SDM11VMH
modulator via Cat-5 wiring

SDM2VC

343.00

...

1

Color, double gang in-wall, 8 lux, adjustable aim,
used with and powered by SDM11VMB/SDM11VMH
modulator via Cat-5 wiring

SDM2VCC

533.00

...

1

IR remote control target, coaxial in/out, locate at television

SDM1VIR

82.00

...

1

IR remote control emitter, locate at video source

SDM2VIR

20.40

...

1

White wall plate 4 phone and 2 video

SDM10PVWPW

19.70

...

10

White wall plate 1 data, 2 phone and 2 video

SDM10DPVWPW

17.40

...

10

Almond wall plate 4 phone and 2 video

SDM10PVWPA

19.70

...

10

Almond wall plate 1 data, 2 phone and 2 video

SDM10DPVWPA

17.40

...

10

Ivory wall plate 4 phone and 2 video

SDM10PVWPI

19.70

...

10

Ivory wall plate 1 data, 2 phone and 2 video

SDM10DPVWPI

17.40

...

10

AC outlet accessory, mounts in enclosures, 2 duplex
receptacles (not included) accepts 2 power supplies,
UL Listed, 120 Vac

SDM4AC

30.50

5.5

1

AC outlet accessory, mounts in enclosures, 4 duplex
receptacles (not included) accepts 4 power supplies,
UL Listed, 120 Vac

SDM8AC

36.50

11b

1

Adapter bracket to mount ChannelPlus 3400 or 8200 on
Square D Multi-Link grid

SDM1A

19.10

2

1

Adapter bracket to mount RJ and type F connectors on
Square D Multi-Link grid

SDM6A

19.10

2

1

Wire Spacer Mezzanine, Universal Grid, lifts modules 1"
above grid, providing wire management capabilities,
11.2"h x 6.5"w

SDM12WS

29.20

12

1

Universal heavy duty isolation mounting bracket for nonSquare D Multi-Link products. Load rated 60 pounds.

SDM1IMB

58.00

c

1

Universal light duty isolation mounting bracket for nonSquare D Multi-Link products. Load rated 10 pounds.

SDM2IMB

LOAD CENTERS

Data Hubs

Video Cameras

SDM2VC/SDM2VCC

IR Controls

Wall Plates
SDM1VC/SDM1VCC

Accessories

SDM18BW with optional modules

28.60

c

1

Patch Cord 1 foot length, Cat-5, RJ-45 plugs on both ends SDM1DC

7.70

...

1

Patch Cord 2 foot length, Cat-5, RJ-45 plugs on both ends SDM2DC

9.60

...

1

Enclosure Coupling Tube for stacking enclosures, 2 inch
conduit

SDM2C

15.20

...

1

Plastic grommet for 2" enclosure knockout, (5) pack

SDM2G

2.90

...

1

Cover Lock Kit

SDMLK

29.20

...

1

Replacement snap locks, lock Square D Multi-Link
modules to grid, black (10) pack

SDM10SL

11.40

...

1

Attenuator, 3 dB

SDM2503

2.70

...

10

Attenuator, 6 dB

SDM2506

2.70

...

10

Low Pass Filter, Channel 91

SDM600LPF

38.90

...

1

a Requires 7" of grid mounting space per column, 14" total.
b Requires 5.5" of grid mounting space per column, 11" total.
c Space required is dependent upon size of the device utilizing the mounting bracket.

For additional information, reference Catalog #1400CT0101R3/03.

© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE7

Discount
Schedule

37

Metering
T H E

W I D E S T

S E L E C T I O N
I N

T H E

I N D U S T R Y

Metering Equipment
Schneider Electric provides the most reliable and most versatile line
of metering equipment in the industry for residential and commercial
applications.
As fewer utilities provide meter sockets it’s important to have one reliable
source that meets all your needs. From individual meter sockets to
multi-metering centers there’s no better choice than Square D.
■ Individual and Horizontal ganged meter sockets
■ Meter-Pak and EZ Meter-Pak multi-metering equipment

Individual Meter Sockets
Square D individual meter sockets have provisions to feed a downstream
main lug load center (with a maximum of 6 service disconnects), main
breaker load center, or an individually enclosed service disconnect. 400
ampere, studs only units have provisions for mounting dual load side lugs
to feed two downstream main breaker load centers or two individually
enclosed disconnects.

EZ Meter-Pak® Multi-Metering Equipment
These exclusive Square D Meter Centers not only make it easier to install
multi-unit metering equipment, but also provide a more economical option
than separately purchasing individual meter sockets.
EZ Meter-Pak meter center enclosures meet NEC wire bending
requirements, and are designed for wall mounting only (not suitable for
floor mounting). All unmetered conductor compartments are sealable by
the utility company.

38

Metering
Individual Meter Sockets
Class 4131

www.SquareD.com
For the most up-to-date information

Individual Meter Sockets—Ring and Ringless Type
• Available single or three phase, 600 Vac max., with and without horn or lever bypass, overhead and underground
service feed.
• 10,000 RMS symmetrical amperes short circuit current rating (or higher with utility approval).
• UL Listed, NEMA 3R enclosure.
• Units supplied with bonded neutral.
• Units supplied with hub opening in top endwall require the use of a bolt-on hub, or closing plate.
• Units supplied with solid top are for underground feed only.
• Accessories, refer to page 40.
This metering is generally utility specific. Always check with local utility company before installing.
Contact your nearest Square D/Schneider Electric sales office for additional catalog numbers, if required by utility.
Lug Wire Range (Al/Cu)

UTRS101B

Ampere Jaw
Rating
(Cont.) Qty.

Service
Type

Catalog
Number
a

Line, Load,
and Neutral
(AWG/kcmil)

Price

Wire
Binding

Enclosure Information
Top Endwall Conf.

Gnd.
(AWG)

Box
No.
see
page
41

Material

Hub
Openingb

Closing
Plate b

#14–2
#14–2
#14–2
#14–2
#14–2

Steel
Steel
Aluminum
Steel
Steel

Solid Topd
Series A
Series A
Series A
Series A

...
ACP
ACPA
ACP
ACP

1R
1R
1R
1R
1R

#14–2
#14–2
#14–2
#14–2
#14–2
#14–2

Steel
Aluminum
Steel
Steel
Aluminum
Steel

Series A
Series A
Solid Topd
Series A
Series A
(2)Series A

ACP
ACPA
...
ACP
ACPA
(2)ACPg

3R
3R
5R
5R
5R
7R

Ringless Type, 1-Phase, 3-Wire 600 Vac Max., Without Bypass or Jaw Release
125
125
125
125
125

4
4
4
4
5

UG
OH
OH
OH
OH/UG

UTZRS101Ad
UTRS101B
UATRS101B
URS101BCPL
1003880Ae

200
200
200
200
200
200

4
4
4
4
4
4

OH
OH
UG
OH/UG
OH/UG
OH/UG

UTRS202B
UATRS202B
UTRS213Ad
UTRS213Be
UATRS213Be
U92197CCCPL g

$ 82.00
82.00
91.00
90.00
107.00

#8–2/0
#8–2/0
#8–2/0
#8–2/0
#8–2/0

118.00
130.00
141.00
141.00
150.00
160.00

#8–250
#8–250
#1/0–350
#1/0–350
#1/0–350
#1/0–350

1
/2" HEX
SLOTTED
SLOTTED
SLOTTED
SLOTTED
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"

HEX
HEX
HEX
HEX
HEX
HEX

UTRS202B
(cover not shown)

125
125
125
125

4
5
4
5

OH/UG
OH
OH
OH/UG

UHTRS101B
UGHTRS101Lc
URS101BDQh
UGHTRS111Cf

107.00
107.00
92.00
138.00

#8–2/0
#8–2/0
#8–2/0
#8–2/0

200
200
200
200
200
200

4
4
4
4
4
4

OH/UG
OH
OH/UG
OH/UG
UG
UG

UBHMRS212Be
UHTRS202B
UHTRS212Be
UHTRS213Be
UHTRS223Ad
URS212ADQdh

140.00
137.00
137.00
142.00
181.00
135.00

#8–250
#8–250
#8–250
#1/0–350
#1/0–350
#8–250

SLOTTED
SLOTTED
1/2" HEX
SLOTTED
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"

HEX
HEX
HEX
HEX
HEX
HEX

#14–2
#14–2
None
#14–2

Steel
Steel
Steel
Steel

Series A
A125c
Series A
Series A

ACP
...
ACP
ACPf

1R
1R
1R
4R

None
#14–2
#14–2
#14–2
#14–2
None

Steel
Steel
Steel
Steel
Steel
Steel

Series A
Series A
Series A
Series A
Solid Topd
Solid Top

ACP
ACP
ACP
ACP
...
...

4R
3R
4R
5R
2R
4R

Ringless Type, 1-Phase, 3-Wire 600 Vac Max., With Lever Bypass and Jaw Release
200
200
200
200
320

4
4
5
5
4

OH
OH/UG
OH
OH/UG
OH/UG

UTH4203T
UTH4213Te
UTH5203T
UTH5213Te
UTH4330Tei

310.00
319.00
329.00
376.00
499.00

#6–350
#6–350

1/2"
1/2"

HEX
HEX

#14–2
#14–2

Steel
Steel

Series A-L
Series A-L

ACPL
ACPL

8R
9R

#6–350
#6–350

1/2"
1/2"

HEX
HEX

#14–2
#14–2

Steel
Steel

Series A-L
Series A-L

ACPL
ACPL

8R
9R

dia. studs

#14–1/0

Steel

Series A-L

ACPL

11R

Studs Only

3/8"

Ringless Type, 3-Phase, 4-Wire 600 Vac Max., With Lever Bypass and Jaw Release
200

7

OH/UG

UTH7213Te

444.00

#6–350

320

7

OH

UTH7300Ti

553.00

Studs Only

1/2"
3/8"

HEX

#14–2

Steel

Series A-L

ACPL

9R

dia. studs

#14–1/0

Steel

Series A-L

ACPL

10R

Steel

Series A-L

ACPL

12R

Aluminum

Series A-L

ACPLA

12R

Ringless Type, 3-Phase, 4-Wire 600 Vac Max., Bolt-On Socket Without Bypass
UTH5203T
(cover not shown)

400
400

7
7

OH/UG
OH/UG

UK7T ei
UAK7T ei

1615.00
1785.00

Studs
Only

1/2–20"
dia. studs

1/2–20"
dia. studs

Studs
Only

1/2–20"

1/2–20"

dia. studs

dia. studs

Ring Type, 1-Phase, 3-Wire 600 Vac Max., Without Bypass or Jaw Release

a
b
c
d
e
f
g
h
i
j

125

4

OH/UG URTRS101Bej

$ 82.00

200

4

OH/UG URTRS213Bej

141.00

#8–2/0
#1/0–350

SLOTTED
1/2"

HEX

#14–2

Steel

Series A

ACP

1R

#14–2

Steel

Series A

ACP

5R

Device requires approval from the serving utility, consult your nearest Square D/Schneider Electric sales office.
Order appropriate bolt-on hub or closing plate separately and install on TOP endwall.
Device supplied with 1-1/4" bolt-on hub (Cat.No. A125) mounted on TOP endwall.
Device supplied with solid top endwall (without hub opening).
When unit is installed for underground feed, the appropriate closing plate must be ordered separately and installed over hub opening in TOP endwall of device.
Device supplied with closing plate (Cat. No. ACP) mounted on TOP endwall.
Device supplied with two closing plates (Cat. No. ACP) mounted in TOP endwall.
Contains “Duquesne Light Co.” approved label.
Order lugs separately, refer to accessories, page 40.
Device supplied with stainless steel, snap-on sealing ring.

URTRS213B

© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE4

Discount
Schedule

39

METERING EQUIPMENT

Ringless Type, 1-Phase, 3-Wire 600 Vac Max., With Horn Bypass, Without Jaw Release

Metering
Ganged and Test Block Sockets and Accessories
Class 4131

www.SquareD.com
For the most up-to-date information

Horizontal Ganged Meter Sockets
• Single phase, 600 Vac max., main lugs only, 2 through 6 meter positions, with and without horn or lever
bypass, end or center feed, overhead and underground service feeds
• 10,000 RMS symmetrical amperes short circuit current rating (or higher with utility approval)
• UL Listed, NEMA 3R enclosure
• Supplied with ground lugs
UT2R1121B

• Supplied with hub opening in top endwall, requires the use of a bolt-on hub, or closing plate

This metering is generally utility specific. Always check with local utility company before installing.
Contact your nearest Square D/Schneider Electric sales office for additional catalog numbers, if required by utility.
Ringless Type, 1-Phase, 3-Wire, 600 Vac Max., Without Bypass or Jaw Release
Branch Ratings
Amperes
(cont.)

Number
of Positions

Socket
Jaw
Qty.b

Service
Type

100

2
3
4
5
6

4

OH/UG

2
4
200

5

4

OH/UG

METERING EQUIPMENT

6

Top Endwalla
Main Lugs
Branch Lugs
Phase & Neutral Phase
& Neutral Hub Type Closing Plate
Al/Cu
(Order
(Order
Al/Cu (AWG)
(AWG/kcmil)
Separately) Separately)

Mains
Rating

Catalog
Number

Price

200
205
205
250
300

UT2R1121B
UT3R1121B
UT4R1131B
UT5R1131B
UT6R1131Bc

$ 302.
373.
440.
605.
771.

205
360

UT2R2122B
UT4R2352Tc

431.
737.

#6–250
#1/0–500

500

UT5R2392TU

922.

#1/0–500 or
(2)#1/0–350

1032.

#1/0–500 or
(2)#1/0–350

620

UT6R2392TU

#6–250
#6–250
#6–350
#6–350
#6–350

#8–2/0

#8–250

Box No.
See
page 41

Series A

ACP

13R
13R1
14R
15R
16R

Series A
Series A-L

ACP
ACPL

17R
18R

Series A-L

ACPL

19R

Series A-L

ACPL

20R

a For Hubs and Closing Plates, see Accessories table below.
b Fifth Jaw Kit available to convert 4-Jaw Socket to a 5-Jaw Socket. See Accessories table below.
c For 120/240 Volt, Three-Wire, Single Phase Dwelling services see NEC Table 310-16 Note 3.

Meter Sockets Accessories
Description
FIFTH JAW KIT
Converts a 4-jaw meter socket to a 5-jaw meter socket.
For use on meter sockets supplied without lever bypass
or jaw release only.
CLOSING PLATES (to seal hub openings)
For Series A (steel)
For Series A (aluminum)
For Series A-L (steel)
For Series A-L (aluminum)

EMT3225CB

HUBS (listed by conduit size)
Series A:
1.00 inch
1.25 inch
1.50 inch
2.00 inch
2.50 inch
Series A-L:
2.00 inch
2.50 inch
3.00 inch
3.50 inch
4.00 inch
Series B:
3.00 inch

EMT3225CB
Without Covers

Surface Mount, Ring Type, Meter Main with Test Block Bypass
(Meets EUSERC Requirements)
Supplied with bondable neutral, suitable for use as service equipment. Suitable for
overhead or underground service. UL Listed File E6294.
System
(Incoming)
and
Service
(Outgoing)

120/240 Vac
1Ø3W

208Y/120 Vac
3Ø4W
or
240/120 Vac
3Ø4W Delta

Meter Ampere
Socket Rating
Type
(Max.)

5-Jaw

7-Jaw

200 A

200 A

Short
Circuit
Current
Rating

Catalog
Numberf

42k Max. EMT1225CB

22k Max. EMT3225CB

Price

Main
Circuit Breaker
Type
(Order
Separately)d

$2730.

2-pole,
Type
QB, QD,
QG, QJ, QOe,
QO-VHe
or QOHe

3570.

3-pole,
Type QB, QD,
QG or QJ

ADAPTER PLATE
To allow the use of a Series A Hub
on a device that is setup for a series A-L Hub.

Load
Neutral Lug
Wire Size
(AWG-kcmil)

#6–300 Al/Cu

#6–350 Al/Cu

#4–300 Al/Cu

#6–300 Al/Cu

#4–300 Al/Cu

ACP
ACPA
ACPL
ACPLA

8.90
7.90
12.20
11.00

A100
A125
A150
A200
A250

22.60
22.60
22.60
31.90
40.40

A200L
A250L
A300L
A350L
A400L

55.00
58.00
74.00
76.00
79.00

B300

124.00u

AAP

22.50

ARP00118h

25.40

ARP00129h

36.80

Includes three, two-barrel lugs (#6-350 kcmil)

ARP00427h

90.00

ARP00026h
29008G
29008W

11.10
13.40
13.40

h Order only. Not stocked in PDS. Order point: Lexington.
Equipment
Ground Lug
Wire Size
(AWG-kcmil)

9.90

Includes one, two-barrel lug (#6-250 kcmil)

EMT Terminal Datag
Service
Ground Lug
Wire Size
(AWG-kcmil)

$

Includes one, single barrel lug (#4-600 kcmil)

d Refer to page 50 to select main circuit breaker.
e Requires use of EZM125QOA adapter (order separately). Refer to page 50 for pricing.
f Refer to page 41 for box dimensions.

Line
Neutral Lug
Wire Size
(AWG-kcmil)

A5J

Price

LUG KITS
For use on meter sockets supplied with Line, Load,
and Neutral Studs only. Be sure to order enough lugs
for each device (a typical 1-Phase device requires 6 lugs).

SEALING RING (Non-Standard)
Snap-on Stainless Steel
Latch-Type Stainless Steel
Screw Type Aluminum

Line
Phase Lug
Wire Size
(AWG-kcmil)

Catalog
Number

g Refer to circuit breaker listings for usable load lug wire sizes.

40

uDE1A

DE4

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Metering
Individual, Ganged and Test Block Sockets
Dimensions

www.SquareD.com
For the most up-to-date information

W

D

Hub
Opening

Meter
Socket

D

Solid
Top

Meter
Socket
Offset

H

A,B,C,D,E

W

Knockout Information and Enclosure Dimensions

W

Hub
Opening

Meter
Socket
H

H

E,F,G

S
A,B,C,D C,D,E,F A,B,C,D

S A

1R
D

A

2R

W

D

Hub
Opening

3R, 6R
Hub
Opening

W

Meter
Socket
Offset

Meter
Socket

D

W

Hub
Opening

Meter
Socket

H

C,D,E,F,G
S

S

C,D,E,F,G

F,G,H

H

D,E,F,G

A,B

A

S

A

H

F,G,H

A,B

S
F,G,H

D,E,F,G

W

D

Hub
Opening

8R

W

D

Hub
Opening

H

F,G,H
S

H

F,G,H,I

A,B

A

A

S

F,G,H

F,G,H,I

9R

10R

W

D

Hub Opening
(Max. Conduit Size)a

1R
2R
3R
4R
5R
6R
7R

10.88
13.00
14.00
14.00
15.00
15.50
17.13

8.00
13.00
8.00
11.00
11.00
8.00
13.00

3.50
4.94
4.38
4.38
4.38
4.36
4.94

Series A
Solid Top
Series A
Series A
Series A
Series A
(2) Series A

8R
9R
10R
11R

19.00
19.00
34.50
36.62

10.50
13.00
15.00
15.00

4.94
4.94
5.68
5.68

Series A-L
Series A-L
Series A-L
Series A-L

12R

43.00

20.25

6.00

Series A-L

13R
13R1
14R
15R
16R

14.12
14.12
14.12
14.12
14.12

24.31
32.50
40.62
48.75
57.00

4.50
4.50
4.50
4.50
4.50

Series A
Series A
Series A
Series A
Series A

17R
18R
19R
20R

14.12
14.12
14.12
14.12

24.31
40.62
54.75
63.00

5.38
5.38
5.38
5.38

Series A
Series A-L
(2) Series A-L
(2) Series A-L

Hub
Opening

H

F,G,H,I
A

H

a Refer to page 40 for closing plates and hubs.

W

Meter
Socket
Offset

Meter
Socket

Meter
Socket
A,B

F,G,H

7R

4R, 5R
D

A

Dimensions (Inches)
Box
No.

Knockouts
Symbol

S

A

B

C

Conduit Size
(inches)

5⁄16 b

1⁄2

3⁄4

1

D

E

11⁄4 11⁄2

W

Meter
Socket

2

21⁄2

3

31⁄2

4

C,D,E,F,G
(13R, 17R)

W

D

Main
Lugs
S

Meter
Socket

H

Main
Lugs
S

A

C,D,E,F,G (13R)
F,G,H (17R)

C,D,E,F,G
(13R, 17R)

C,D,E,F,G
(14R, 18R)

H

A

C,D,E,F,G (14R)
F,G,H (18R)

13R and 17R

12R

J

Hub Opening

W

H

A,B

I

11R

Meter
Socket
G,H,I,J

H

F,G,H,I

D

Hub
Opening

G

b Knockout for ground conductor.

S

Hub Opening
D

F

METERING EQUIPMENT

D

C,D,E,F,G
(14R, 18R)

14R and 18R

Hub Opening
W

D

Meter
Socket

Main
Lugs
S

C,D,E,F,G

H

D

Meter Socket
Left position omitted on
5-Gang unit (15R)
W

Hub Opening

A

C,D,E,F,G

Main
Lugs

C,D,E,F,G

S

13R1

7.50
191

22.44
570

Supplied with (2)
ACP Closing Plates.
Order A-Hubs
separately for
overhead service
feed.

C,D,E,F,G

H

A

C,D,E,F,G

C,D,E,F,G

15R and 16R

D

Meter Socket
Left position omitted on
5-Gang unit (19R)
W

Hub Opening

40.00
1016

C,D,E (3 Locations)

Main
Lugs

E,F,G,H (8 Locations)

S

A,B

C,D,E,F,G
(19R, 20R)

H

A

F,G,H
(19R, 20R)

C,D,E,F,G
(19R, 20R)

19R and 20R
EMT1200CB and EMT3200CB
© 2004 Schneider Electric
All Rights Reserved
6/7/04

41

Metering
MP METER-PAK™ Meter Centers
Class 4141

www.SquareD.com
For the most up-to-date information

Ring and Ringless Type Devices
•
•
•
•
•
•
•
•
•
•
•
•
•

Consult local utility for approval before installation.
120/240 Vac 1 Phase 3 Wire.
Main lugs only—two to six meter sockets.
Enclosures are indoor/rainproof NEMA 3R construction.
Suitable only for use as service equipment.
Swingable mounting feet supplied at bottom of device.
Factory installed mechanical lugs, alternate lugs and NEMA/EUSERC lug landing kits available.
Surface mount, convertible to semi-flush with field installed flange kit.
Ring type devices supplied with 4-jaw meter sockets (5th jaw kits available, order separately).
Ringless type devices supplied with 5-jaw meter sockets, available with and without horn or lever bypass.
Provisions for mounting 2-pole circuit breaker for each meter socket position (order circuit breakers separately).
Mounting channel supplied, except for box 1R (125 A, 2-position).
Combination overhead/underground feed.

Step 1: Select Ring or Ringless Type MP METER-PAK Metering Equipment
Ring Type MP METER-PAK Metering Equipment with 125 A (42k RMS Symmetrical Amperes Maximum SCCR) or
200 A (22k RMS Symmetrical Amperes Maximum SCCR) Meter Socket Positions
Amps
per Pos.

No. of
Pos.
2

METERING EQUIPMENT

125

Factory Installed
Main Lug Ampacity
(See page 43 for
alternate lugs)
200

Main Bus
Ampacity

Catalog
Numberb

Price

200

MP22125a

$ 651.

3

300

300

MP33125b

791.

4

400

400

MP44125b

1153.

5

500

MP55125b

1386.

6

400 Al
500 Cu
400 Al
500 Cu

600

MP66125b

1610.

2

400

400

MP42200b

849.

3

400

400

MP43200b

1434.

200
4

400

600

MP64200b

1876.

5
6

600 Al, 750 Cu
600 Al, 750 Cu

800
800

MP85200b
MP86200b

2251.
2693.

Line Lug Wire
Size Al/Cu
AWG/kcmil
(1) 4–250
(1) 1/0–600 or
(2) 1/0–250
(1) 1/0–600 or
(2) 1/0–250
(1) 1/0–600 or
(2) 1/0–250
(1) 1/0–600 or
(2) 1/0–250
(1) 1/0–600 or
(2) 1/0–250
(1) 1/0–600 or
(2) 1/0–250
(1) 1/0–600 or
(2) 1/0–250
(2) 3/0–500
(2) 3/0–500

Circuit
Breaker Type
(2-Pole)

QO,
QO-VH,
QOH

QOM2-MM,
QOM2-MVH

Hub Prov.

Semi-Flush
Flange Kit

Wt Lbs

A/B300

MPSF12

46

Box
No.
(See
pg. 44)
1R

A-L

MPSF14

95

2R

A-L

MPSF14

97

2R

A-L

MPSF16

130

3R

A-L

MPSF16

132

3R

MPSF23

99

4R

MPSF23

99

4R

MPSF24

135

5R

MPSF26
MPSF26

173
173

6R
6R

A-L

a Meets EUSERC standards.
b Meets EUSERC standards with addition of lug landing kit, MMSK2.

Ringless Type MP METER-PAK Metering Equipment with 125 A (42k RMS Symmetrical Amperes Maximum SCCR) or
200 A Type MPR, MPH (22k RMS Symmetrical Amperes Maximum SCCR) or
225 A Type MPL (100k RMS Symmetrical Amperes Maximum SCCR) Meter Socket Positions
Amps
No.
Per
Pos. of Pos.
2
3
125

225

200

300

Horn
Bypass
Catalog
Number

Lever
Bypass
Catalog
Number

No. Bypass
Catalog
Number

Price

200

MPR22125

$ 663. MPH22125

$ 668.

....

...

300

MPR33125

813. MPH33125

835.

....

...

Main Bus
Ampacity

Price

Price

4

400

400

MPR44125

1187. MPH44125

1220.

....

...

5

400 Al
500 Cu
400 Al
500 Cu
400
400
400
300
400
400
600 Al, 750 Cu
600 Al, 750 Cu

500

MPR55125

1497. MPH55125

1553.

....

...

600

MPR66125

1743. MPH66125

1810.

....

...

400
400
600
300
400
600
800
800

MPR42200
MPR43200
MPR64200
...
...
...
MPR85200
MPR86200

860.
1457.
1910.
...
...
...
2363.
2827.

866.
1479.
....
1944.
...
MPL32225
...
MPL53225
...
MPL64225
2418.
....
2894.
....

6

200

Factory Installed
Main Lugs
Ampacity
(See page 43 for
alternate lugs)
200

2
3
4
2
3
4
5
6

MPH42200
MPH43200
MPH64200
...
...
...
MPH85200
MPH86200

...
$1159.
1827.
2437.
...
...

Line Lug
Wire Size
Al/Cu
AWG/kcmil
(1) 4–250
(1) 1/0–600 or
(2) 1/0–250
(1) 1/0–600 or
(2) 1/0–250
(1) 1/0–600 or
(2) 1/0–250
(1) 1/0–600 or
(2) 1/0–250

Circuit
Breaker
Type
(2-Pole)

A/B300

Semi-Flush
Flange Kit
MPSF12
MPSF14

QO,
QO-VH,
QOH

(1) 1/0–600 or
(2) 1/0–250

QOM2-MM,
QOM2-MVH

(1) 1/0–600 or
(2) 1/0–250

QB, QD, QG, QJ,
QOe, QO-VHe
or QOHe

(2) 3/0–500
(2) 3/0–500

Hub
Prov.

Box
Wt No.
Lbs (See
pg.
44)
46
1R
95

2R

MPSF14

97

2R

MPSF16

130

3R

MPSF16

132

3R

MPSF23
MPSF23
MPSF24
N/A
N/A
N/A
MPSF26
MPSF26

99
99
135
105
147
200
173
173

4R
4R
5R
7R
8R
9R
6R
6R

A-L

A-L

QOM2-MM,
QOM2-MVH

c Requires use of EZM125QOA adapter (order separately). Refer to page 50 for pricing.

UL Listed short circuit current rating depends on lowest interrupting rating of circuit breaker installed. (See page 43)

For additional information, reference Catalog #4100CT9801.

42

DE4

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Metering
MP METER-PAK™ Meter Centers
Tenant Circuit Breakers & Accessories

www.SquareD.com
For the most up-to-date information

Step 2: Select Tenant Circuit Breakers
10,000 AIR
120/240 Vac

Amps

Price
u

22,000 AIR
120/240 Vac

Price
u

42,000 AIR
120/240 Vac

Price
u

100,000 AIR
120/240 Vac

Price
u

For Use in 125 A Max. Type MP, MPR and MPH METER-PAK Metering Equipment

QO2100VH
2-Pole, Plug-on Type
Circuit Breaker

60

QO260

$ 44.70

QO260VH

$ 97.00

QOH260a

$ 211.00

...

...

70

QO270

89.00

QO270VH

149.00

QOH270a

352.00

...

...

80

QO280

126.00

QO280VH

210.00

QOH280a

434.00

...

...

90

QO290

126.00

QO290VH

210.00

QOH290

434.00

...

...

100

QO2100

126.00

QO2100VH

210.00

QOH2100

434.00

...

...

125

QO2125

285.00

QO2125VH

689.00

QOH2125

926.00

...

...

For Use in 200 A Max. Type MP, MPR and MPH METER-PAK Metering Equipment
100

QOM2100MM

316.00

QOM2100MVH

762.00

...

...

...

...

125

QOM2125MM

316.00

QOM2125MVH

762.00

...

...

...

...

150

QOM2150MM

316.00

QOM2150MVH

762.00

...

...

...

...

175

QOM2175MM

316.00

QOM2175MVH

762.00

...

...

...

...

200

QOM2200MM

316.00

QOM2200MVH

762.00

...

...

...

...

65,000 AIR
120/240 Vac

Price
u

100,000 AIR
120/240 Vac

Price
u

For Use in 225 A MPL Lever Bypass METER-PAK Metering Equipment

QDP22200TM
2-Pole, Bolt-on Type
Circuit Breaker

a
b
c
d

QOM2200MVH

Price
u

25,000 AIR
120/240 Vac

Price
u

40

QO240b

44.70

QO240VHbc

97.00

QOH240bd

211.00

...

...

50

QO250b

44.70

QO250VHbc

97.00

QOH250bd

211.00

...

...

QOH260bd

60

QO260b

44.70

QO260VHbc

97.00

70

QBP22070TM

316.00

QDP22070TM

762.00

QGP22070TM

1014.00

QJP22070TM

$1260.00

80

QBP22080TM

316.00

QDP22080TM

762.00

QGP22080TM

1014.00

QJP22080TM

1260.00

90

QBP22090TM

316.00

QDP22090TM

762.00

QGP22090TM

1014.00

QJP22090TM

1260.00

100

QBP22100TM

316.00

QDP22100TM

762.00

QGP22100TM

1014.00

QJP22100TM

1260.00

110

QBP22110TM

316.00

QDP22110TM

762.00

QGP22110TM

1014.00

QJP22110TM

1260.00

125

QBP22125TM

316.00

QDP22125TM

762.00

QGP22125TM

1014.00

QJP22125TM

1260.00

150

QBP22150TM

316.00

QDP22150TM

762.00

QGP22150TM

1014.00

QJP22150TM

1260.00

175

QBP22175TM

316.00

QDP22175TM

762.00

QGP22175TM

1014.00

QJP22175TM

1260.00

200

QBP22200TM

316.00

QDP22200TM

762.00

QGP22200TM

1014.00

QJP22200TM

1260.00

225

QBP22225TM

316.00

QDP22225TM

762.00

QGP22225TM

1014.00

QJP22225TM

...

...

1260.00

Order only. Not stocked in PDS. Order Point: Lincoln.
Requires use of EZM125QOA adapter (order separately). Refer to page 50 for pricing.
QOVH tenant circuit breakers are rated 22,000 AIR at 120/240 Vac.
QOH tenant circuit breakers are rated 42,000 AIR at 120/240 Vac.

UL Listed Short Circuit Current Rating depends on lowest interrupting rating of circuit breaker installed.
(Refer to the table on the bottom of page 52 for Square D certified ratings for downstream panelboards and
load centers.)
Accessories
Accessories (Continued)
Catalog
Number

Description
Fifth Jaw Kit

5J

Horn Bypass Kit

MMHB

Price

Description

182.00

11.10

125 A Ring Style
2 Position Top Meter (Only)

MM125MBe

114.00

NEMA Lug Landing Kit:
For use ONLY on MPL43225 and
MPL64200 with optional lugs. See wiring
diagram of each device for optional lugs.

125 A/200 A Ring Style

MM200MBe

114.00

MP Meter-Pak Wireway:

2920910001
29008W
ARP00026

5.00
13.40
11.10

Slider Type Manual Circuit Closing:

Sealing Rings:
Snap-on Aluminum
Screw Type Aluminum
Snap-on Type Stainless Steel
Meter Cover-Lexan®

29007

6.70

Optional Lug Kits:
(1) 1/0–600 AWG/kcmil or
(2) 1/0–250 per phase

Catalog
Number

NEMA/EUSERC Lug Landing Kit:
For 3 through 6 position 125 A and 200 A
devices. Each pad rated 600 A maximum MMSK2g
and includes (2) 1/2-13 studs and
mounting hardware.

$ 12.20

QO Adapter for Bolt-on Q2M tenant circuit EZM125QOA
breakers (40–125 A, 2-pole)

MMLK500

211.00

Price

$123.00

MMSK4

184.00

125 A 2 Position ONLY

MP43X8PED

294.00

125 A 3–6 Position

MP43X11PED

336.00

200 A 2–6 Position

MP43X11PED

336.00

MPL32-200

MP35X11PEDh

336.00

MPL53-200

MP43X11PED

336.00

MPL64-200

MP35X11PEDh

336.00

MMLK250fg

100.00

(2) 3/0–500 AWG/kcmil per phase

MMLK500g

133.00

Used ONLY with MP43X8PED

MP12X8PEDEXTh

68.00

(2) 2–600 AWG/kcmil per phase

MMLK600g

155.00

Used with MP43X11PED &
MP35X11PED

MP12X11PEDEXTh

84.00

Semiflush Kits:
125 A 2 Position
125 A 3–4 Position
125 A 5–6 Position
200 A 2–3 Position
200 A 4 Position
200 A 5–6 Position

MPSF12
MPSF14
MPSF16
MPSF23
MPSF24
MPSF26

67.00
89.00
145.00
96.00
114.00
170.00

MP Meter-Pak Wireway Extensions:

e The meter center short circuit current rating is 10,000 amperes RMS
symmetrical when manual circuit closing is used. Not rated for continuous
duty.
f Standard lug for 3 through 6 position 125 A and 2 through 4 position 200 A
devices.
g Cannot be installed on 2 position 125 A device.
h Order only. Not stocked in PDS. Order point: Lexington.

See page 40 for hubs and closing plates
For additional information, reference Catalog #4100CT9801.
© 2004 Schneider Electric
All Rights Reserved
6/7/04

u DE2A

DE4

Discount
Schedule

43

METERING EQUIPMENT

10,000 AIR
120/240 Vac

Metering
MP METER-PAK™ Meter Centers
Dimensions, Knockouts

www.SquareD.com
For the most up-to-date information
A-L Hub Opening Supplied
with ACPL Closing Plate
A-L Hub Opening Supplied
with ACPL Closing Plate

7.28

A Hub Opening Supplied
with ACP Closing Plate

185

7.28

185

618

Top Position
Omitted on
3-Gang Unit

12.28

Mounting Holes
(4) Locations
(Supplied without
Mounting Channel)

7.28

24.34

185

36.46
926

312

9.00

Top Left
Position
Omitted on
5-Gang Unit

229
Typ.

37.50
953

9.00

48.12

229
Typ.

1222

9.00
229

42.37
1076

18.50
470

11.19

11.19

C,D,F

C,D,F

284

C,D,F

E,F,G,H,I,J and
A-L Hub Provision

C,D,F

D,F,G and A or
B300 Hub Provision

284

C,D,F

C,D,F

A,B

A

Box 1R

A

A,B

Box 2R

Box 3R

E,F,G,H,I,J and
A-L Hub Provision

A-L Hub Opening Supplied
with ACPL Closing Plate
A-L Hub Opening Supplied
with ACPL Closing Plate

A-L Hub Opening Supplied
with ACPL Closing Plate

8.28
210

8.28

8.28
210

210

29.44

METERING EQUIPMENT

748

46.68

29.44

1186

748

Top Position
Omitted on
2-Gang Unit

Top Left
Position
Omitted on
5-Gang Unit

9.00
229
Typ.

9.00

9.00

229
Typ.

229
Typ.

52.00
1321

43.41

43.41

1103

1103

12.22

12.22
310

C,D,F

12.22

C,D,F

E,F,G,H,I,J and A-L Hub Provision

E,F,G,H,I,J and
A-L Hub Provision

E,F,G,H,I,J and
A-L Hub Provision

C,D,E,F

C,D,E,F

C,D,E,F

Box 4R

310

C,D,F

310

A,B

A,B,C

Box 5R

A,B

Box 6R
A-L Hub Opening Supplied
with ACPL Closing Plate

A-L Hub Opening Supplied
with ACPL Closing Plate

A-L Hub Opening Supplied
with ACPL Closing Plate

9.62

9.62

9.62

244

244

244

35.37

35.37

19.43

898

898

494

53.12

14.00

1349

356

14.00

60.25

67.37

356
Typ.

1530

34.00

1711

14.00

13.43

864

356
Typ.

341

C,D,E,F
C,D,E,F

13.43
341

E,F,G,H,I,J and
A-L Hub Provision

C,D,E,F

A,B

Box 8R
Box 7R

44

C,D,E,F

E,F,G,H,I,J and
A-L Hub Provision

C,D,E,F

E,F,G,H,I,J and
A-L Hub Provision

C,D,E,F

A,B

Knockouts
Symbol

A

B

C

Conduit Size
(inches)

1⁄2

3⁄4

1

D

E

11⁄4 11⁄2

F

G

H

I

J

2

21⁄2

3

31⁄2

4

Box 9R

A,B

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Metering
EZ METER-PAK® Meter Centers
Single Phase—Indoor/Rainproof

www.SquareD.com
For the most up-to-date information

1Ø3W EZ METER-PAK Meter Centers—
UL Listed
Select EZM meter center short circuit current rating RMS
symmetrical amperes from table on page 53. Using
this table as a reference, make the following
selections:

➀ Select EZM single phase main device below with an

equal or higher short circuit rating than the application.

➁ Select EZM single phase branch units; page 46.
➂ Select proper 2-pole type QO, QO-VH, QOH,

QBP-TM, QDP-TM, QGP-TM or QJP-TM branch
circuit breakers for use as tenant mains in branch unit;
page 50.

➃ Select accessories as required; page 50.
➄ Dimensions; page 51.

➀ Main Devices—NEMA 3R Construction
Overhead/Underground Feed

System
Type

Ampere
Rating

Horizontal
Cross Bus
Rating
and Bus Bar
Material

Catalog Number

Width
(Dim.
see
pg. 51)

Price

Line Side
Lug and Wire Size
(AWG–kcmil)
Conductor Qty.
per Phase and
Neutral
(Factory Installed)

65,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Circuit Breakers (1Ø Incoming and 1Ø Outgoing)

1Ø3W
120/240 Vac

400
600
800
1000
1200
1600

800 A Al
800 A Al
800 A Al

EZM1400CBe
EZM1600CBe
EZM1800CBe

18.66 $ 4120.
18.66
5715.
18.66
7576.

1000 A Al
1200 A Al/Cu
1200 A Al/Cu

EZM11000CBeh
EZM11200CBfg
EZM11600CBfg

18.66
30.19
30.19

10511.
13577.
19936.

(1) #1–600 or (2) #1–250
(3) 3/0–500
(3) 3/0–500
(3) 3/0–500
(4) 1/0–750
(6) 1/0–750

100,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Fusible Switches (1Ø Incoming and 1Ø Outgoing)—
Requires 300 Vac Class T Fuses (Order Separately)
1Ø3W
120/240 Vac

400
600
800
1200

800 A Al
800 A Al
800 A Al
1200 A Al/Cu

EZM1400FS
EZM1600FS
EZM1800FS
EZM11200FSg

18.66
18.66
18.66
30.19

2659.
4652.
5981.
7709.

(1) #1–600 or (2) #1–250
(3) 3/0–500
(3) 3/0–500
(4) 1/0–750

532.
581.
610.
677.

(1) 4–300
(1) 4–300
(2) 3/0–500
(2) 3/0–500

Main Lugs Terminal Boxes (1Ø Incoming and 1Ø Outgoing)c
800 A Al
800A Cu
800 A Al
800A Cu

EZM1225TB
EZM1225TBCU
EZM1400TB
EZM1400TBCU

11.50
11.50
18.66
18.66

600
600
800
800

800 A Al
800A Cu
800 A Al
800A Cu

EZM1600TB
EZM1600TBCU
EZM1800TB
EZM1800TBCU

17.00
17.00
23.93
23.93

665. (1) 350–750 or (2) 1/0–300
810. (1) 350–750 or (2) 1/0–300
824.
(4) 3/0–500
1105.
(4) 3/0–500

1200 A Al
1200 A Cu

EZM11600TBg
EZM11600TBCU

22.33
22.33

2392.
2986.

1600
1600

(6) 3/0–600
(6) 3/0–600

METERING EQUIPMENT

1Ø3W
120/240 Vac

225
225
400
400

Underground Feed Only

System
Type

Ampere
Rating

Horizontal
Cross Bus
Rating
and Bus Bar
Material

Catalog Number
Meets EUSERC
Requirements

Width
(Dim.
see
pg. 51)

Price

Factory Installed
Lug Landings
For Use with
Crimp-Type Lugs
(2-Hole Mounting)
Qty. per Phase
and Neutrala

65,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Circuit Breakers (1Ø Incoming and 1Ø Outgoing)

1Ø3W
120/240 Vac

EZM1800CB

400
600
800
1000
1200
1600

800 A Al
800 A Al
800 A Al

EZM1400CBUe
EZM1600CBUe
EZM1800CBUe

20.46 $ 4253. 1 (Order Lugs Separately)
20.46
6114. 2 (Order Lugs Separately)
20.46
7841. 2 (Order Lugs Separately)

1000 A Al
1200 A Al/Cu
1200 A Al/Cu

EZM11000CBUebh
EZM11200CBUegb
EZM11600CBUfgd

34.19
34.19
30.19

11031. 3 (Order Lugs Separately)
14221. 3 (Order Lugs Separately)
21105. 6 (Order Lugs Separately)

100,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Circuit Breakers (1Ø Incoming and 1Ø Outgoing)
1Ø3W
120/240 Vac

EZM1800CBU

1000
1200

1000 A Al
1200 A Al/Cu

EZM11000CBUeh
EZM11200CBUeg

34.19
34.19

11031. 3 (Order Lugs Separately)
14221. 3 (Order Lugs Separately)

100,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Fusible Switches (1Ø Incoming and 1Ø Outgoing)—
Requires 300 Vac Class T Fuses (Order Separately)
1Ø3W
120/240 Vac

400
600
800
1200

800 A Al
800 A Al
800 A Al
1200 A Al/Cu

EZM1400FSU
EZM1600FSU
EZM1800FSU
EZM11200FSUg

20.46
20.46
20.46
34.19

4120.
6246.
7709.
9436.

1 (Order Lugs Separately)
2 (Order Lugs Separately)
2 (Order Lugs Separately)
3 (Order Lugs Separately)

Main Lugs Terminal Boxes (1Ø Incoming and 1Ø Outgoing). Supplied with isolated neutral (can not be bonded).c

1Ø3W
120/240 Vac

400
400
800
800
1200
1200

800 A Al
800A Cu
800 A Al
800A Cu

EZM1400TBU
EZM1400TBUCU
EZM1800TBU
EZM1800TBUCU

16.16
16.16
24.16
24.16

1029.
1379.
1218.
1633.

1 (Order Lugs Separately)
1 (Order Lugs Separately)
2 (Order Lugs Separately)
2 (Order Lugs Separately)

1200 A Al/Cu
1200 A Cu

EZM11200TBUg
EZM11200TBUCU

32.16
32.16

2483. 3 (Order Lugs Separately)
3327. 3 (Order Lugs Separately)

a For mechanical lugs (3/0 to 600 kcmil) order kit catalog number CMELK4, Price $91.00. Kit includes 4 lugs only.
Multiple kits may be required, consult factory. For crimp-type lugs refer to Anderson Electrical Connector Products
Catalog AEC-40R.
b Has a 100,000 RMS symmetrical ampere short circuit current rating.
c Has a maximum 100,000 RMS symmetrical short circuit current rating when protected by Class R (600 A Max.) or
Class T (800 A Max.) fuses. For other short circuit current ratings refer to table on page 53. Suitable for use on LINE
or LOAD side of service equipment. Use to feed type EZMT branch units for 6-Sub Division Rule applications.
d Does not meet EUSERC Standards. Not stocked in PDS, Order only (allow 6 weeks for delivery). Not UL Listed.
e Available by special order with main circuit breaker supplied with other standard ampere ratings, consult local Field
Office (allow 6 weeks for delivery).
f Ampere rating of the PA circuit breaker supplied with this main can be changed it field by ordering a different set of
rating columns, refer to Digest 173 page 6-25 for listing.
g Supplied with copper horizontal bus bars and aluminum vertical bus bars.
h May be end mounted to feed branch units with 800 A or 1200 A horizontal cross bus.

For additional information, reference Catalog #4100CT9801.
© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE4

Discount
Schedule

45

Metering
EZ METER-PAK® Meter Centers
Single Phase—Indoor/Rainproof

www.SquareD.com
For the most up-to-date information

1Ø3W EZ Meter-Pak Meter Centers — UL Listed

② Branch Devices—NEMA 3R Construction
Branch Units—1Ø Incoming and 1Ø Outgoing
System
Type

Width
(Dim.
see pg.
51)

Horizontal
Cross Bus
Rating
and Bus Bar
Material

Number
of
Meter
Sockets

Ring Type
4-Jaw Meter Socketa
Catalog
Number

Ringless Type
5-Jaw Meter Socket
with Horn Bypass

Ringless Type
5-Jaw Meter Socket
Catalog
Number

Price

Catalog
Number

Price

Price

125 A Maximum (Order Type QO, QO-VH or QOH Circuit Breakers Separately)f

1Ø3W
120/240 Vac
2-Pole Branch
Circuit Breakers

3

800 A Al
800 A Cu

EZM113125
EZM113125CU

$ 957.
1288.

EZMR113125
EZMR113125CU

$ 957.
1288.

EZMH113125
EZMH113125CU

$1170.
1608.

4

800 A Al
800 A Cu

EZM114125
EZM114125CU

1276.
1767.

EZMR114125
EZMR114125CU

1276.
1767.

EZMH114125
EZMH114125CU

1435.
2007.

5

800 A Al
800 A Cu

EZM115125
EZM115125CU

1569.
2206.

EZMR115125
EZMR115125CU

1569.
2206.

EZMH115125
EZMH115125CU

1940.
2764.

6

800 A Al
800 A Cu

EZM116125
EZM116125CU

1861.
2644.

EZMR116125
EZMR116125CU

1861.
2644.

EZMH116125
EZMH116125CU

2366.
3402.

12.25

EZMH114125

225 A Maximum Branch Units (Order Type QB, QD, QG or QJ Circuit Breakers Separately)fi

1Ø3W
120/240 Vac
2-Pole Branch
Circuit Breakers

2

800 A Al
800 A Cu

EZM112225
EZM112225CU

1515.
2126.

EZMR112225
EZMR112225CU

1515.
2126.

EZMH112225
EZMH112225CU

1649.
2326.

3

800 A Al
800 A Cu

EZM113225
EZM113225CU

1861.
2644.

EZMR113225
EZMR113225CU

1861.
2644.

EZMH113225
EZMH113225CU

2046.
2923.

4

800 A Al
800 A Cu

EZM114225
EZM114225CU

2392.
3441.

EZMR114225
EZMR114225CU

2392.
3441.

EZMH114225
EZMH114225CU

2685.
3881.

1200 A Al/CU EZM115225
1200 A Cu
EZM115225CU

3143.
4459.

EZMR115225
EZMR115225CU

3143.
4459.

EZMH115225
EZMH115225CU

3143.
5198.

17.38

METERING EQUIPMENT

5

225 A Maximum Commercial Branch Units
(Order Type QB, QD, QG or QJ Circuit Breakers Separately)i

System
Type

EZML113225

1Ø3W
120/240 Vac
2-Pole Branch
Circuit Breakers

Number
of Meter
Sockets

Ringless Type 5-Jaw Meter Socket
with Lever Bypass and Jaw Releasee

Horizontal
Cross Bus
Rating
and Bus Bar
Material

Catalog
Number

Width
(Dim.
see pg.
51)

Price

Ring Type 5-Jaw Meter Socket
with Test Block Bypass.
Meets EUSERC Requirements
Catalog
Number

Width
(Dim.
see pg.
51)

Price

1

1200 A Al/Cu
1200 A Cu
1200 A Al/Cu

EZML111225
EZML111225CU
EZML111225Db

19.44

$1635.
2453.
1717.

EZMT111225c
...
...

22.42
...
...

$2258.
...
...

2

1200 A Al/Cu
1200 A Cu
1200 A Al/Cu

EZML112225
EZML112225CU
EZML112225Db

19.44

2977.
4466.
3126.

EZMT112225c
...
...

22.42
...
...

4095.
...
...

3

1200 A Al/Cu
1200 A Cu
1200 A Al/Cu

EZML113225
EZML113225CU
EZML113225Db

19.44

4386.
6579.
4605.

EZMT113225cg
...
...

22.42
...
...

6143.
...
...

4

1200 A Al/Cu
1200 A Cu
1200 A Al/Cu

EZML114225
EZML114225CU
EZML114225Db

19.44

5875.
8813.
6169.

...
...
...

...
...
...

...
...
...

400 A Maximum Commercial Branch Units

System
Type

Number
of Meter
Sockets

Main
Cross Bus
Rating
and Bus Bar
Material

Ringless Type 5-Jaw Meter Socket
with Lever Bypass and Jaw Release—
400 A Type LAL Branch Circuit Breaker
Included Factory Installed.deh

Catalog Number

EZMT111225

1Ø3W
120/240 Vac
2-Pole Branch
Circuit Breakers

Width
(Dim.
see pg.
51)

Price

Ringless Type K Bolt-On
4-Jaw Meter Socket with Manual Bypass—
400A Type DJM Branch Circuit Breaker
Included Factory Installed. Ampere rating
field adjustable from 160 A–400 A.

Catalog Number

Width
(Dim.
see pg.
51)

Price

1

1200 A Al/Cu
1200 A Cu

EZML111400
EZML111400CU

23.21

$ 3987.
5981.

...
EZMK111400

...
27.56

...
$4949.

2

1200 A Al/Cu
1200 A Cu

EZML112400
EZML112400CU

23.21

7975.
11963.

...
EZMK112400

...
27.56

...
9687.

a Snap-on aluminum sealing rings supplied as standard.
b Supplied with removable drip hood and equipped with an indoor top endwall with knockouts provided.
c Supplied with bondable neutral, suitable for use as service equipment. Use main lugs tapbox type EZM-TBU for 6-Sub Division Rule applications to feed this
device. Supplied with copper horizontal bus bars and aluminum vertical bus bars.
d Device has limited short circuit current rating, refer to page 53.
e Supplied with Class 320 meter socket.
f For 1200A main cross bus add suffix “X” to catalog number (Example: EZM314125X). Add $147. per device. Allow 6 weeks for delivery.
g Does not meet EUSERC 48" minImum / 75" maximum meter height requirements for outdoor installations.
This device measures 37" minimum / 75" maximum. EUSERC indoor requirements are 36" minimum / 75" maximum.
h Not UL Listed.
i Type QO, QO-VH and QOH branch circuit breakers (40 A–60 A) may be installed with use of EZM125QOA adapter kits, refer to page 50.

For additional information, reference Catalog #4100CT9801.

46

DE4

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Metering
EZ METER-PAK® Meter Centers
Three Phase—Indoor/Rainproof

www.SquareD.com
For the most up-to-date information

3Ø4W EZ METER-PAK Meter Centers—
UL Listed
Select EZM meter center short circuit current rating RMS
symmetrical amperes from table on page 53. Using this
table as a reference, make the following selections:

➀ Select three phase EZM main device below with an

➀ Main Devices—NEMA 3R Construction
Overhead/Underground Feed

System
Type

Horizontal
Bus
Ampere Cross
Rating andRating
Bus Bar
Material

Catalog
Number

Price

Line Side
Lug and Wire Size
(AWG–kcmil)
Conductor Qty.
per Phase
and Neutral
(Factory Installed)

18.66
18.66
18.66

$ 4413.
6831.
9100.

(1) #1–600 or (2) #1–250
(3) 3/0–500
(3) 3/0–500

18.66
30.19
30.19

11351.
15418.
23525.

(3) 3/0–500
(4) 1/0–750
(6) 1/0–750

Width
(Dim.
see
pg.
51)

equal or higher short circuit rating than the application.

➁ Select EZM three phase branch units from
page 48 and 49.

➂ Select proper 2-pole type QO, QO-VH, QOH,

QBP-TM, QDP-TM, QGP-TM or QJP-TM
or 3-pole QBP-TM, QDP-TM, QGP-TM or QJP-TM
branch circuit breakers for use as tenant mains in
branch unit; page 50.

➃ Select accessories as required, page 50.
➄ Dimensions, page 51.

65,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Circuit Breakers (3Ø Incoming and 3Ø Outgoing)
3Ø4W
208Y/120 Vac
OR
240/120 Vac
DELTA

400
600
800
1000
1200
1600

800 A Al
800 A Al
800 A Al

EZM3400CBe
EZM3600CBe
EZM3800CBe

1000 A Al
EZM31000CBei
1200 A Al/Cu EZM31200CBfg
1200 A Al/Cu EZM31600CBfg

100,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Fusible Switches (3Ø Incoming and 3Ø Outgoing)—
Requires 300 Vac Class T Fuses (Order Separately)
3Ø4W
208Y/120 Vac
OR
240/120 Vac
DELTA

400
600
800

800 A Al
800 A Al
800 A Al

EZM3400FS
EZM3600FS
EZM3800FS

18.66
18.66
18.66

2977.
5582.
7710.

(1) #1–600 or (2 )#1–250
(3) 3/0–500
(3) 3/0–500

3Ø4W
208Y/120 Vac
OR
240/120 Vac
DELTA

225
225
400
400

800 A Al
800A Cu
800 A Al
800A Cu

EZM3225TB
EZM3225TBCU
EZM3400TB
EZM3400TBCU

11.50
11.50
18.66
18.66

675.
749.
742.
1286.

(1) 4–300
(1) 4–300
(2) 3/0–500
(2) 3/0–500

600
600
800
800

800 A Al
800A Cu
800 A Al
800A Cu

EZM3600TB
EZM3600TBCU
EZM3800TB
EZM3800TBCU

17.00
17.00
23.93
23.93

797.
1415.
961.
2363.

(1) 350–750 or (2) 1/0–300
(1) 350–750 or (2) 1/0–300
(4) 3/0–500
(4) 3/0–500

1200 A Al
1200 A Cu

EZM31600TBg
EZM31600TBCU

22.33
22.33

2685.
3576.

(6) 3/0–600
(6) 3/0–600

1600
1600

Underground Feed Only

System Type

Horizontal
Bus
Ampere Cross
Rating andRating
Bus Bar
Material

Catalog Number
Meets EUSERC
Requirements

Price

Factory Installed
Lug Landings
For Use with
Crimp-Type Lugs
(2-Hole Mounting)
Qty. per Phase
and Neutrala

20.46
20.46
20.46

$ 4785.
7204.
9410.

1 (Order Lugs Separately)
2 (Order Lugs Separately)
2 (Order Lugs Separately)

34.19
34.19
30.19

11962.
16215.
24780.

3 (Order Lugs Separately)
3 (Order Lugs Separately)
6 (Order Lugs Separately)

Width
(Dim.
see
pg.
51)

65,000 RMS Symmetrical Ampere Short Circuit Current Rating
EZM3600FS

Main Circuit Breakers (3Ø Incoming and 3Ø Outgoing)
3Ø4W
208Y/120 Vac
OR
240/120 Vac
DELTA

400
600
800
1000
1200
1600

800 A Al
800 A Al
800 A Al

EZM3400CBUe
EZM3600CBUe
EZM3800CBUe

1000 A Al
EZM31000CBUebi
1200 A Al/Cu EZM31200CBUegb
1200 A Al/Cu EZM31600CBUfgd

100,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Circuit Breakers (3Ø Incoming and 3Ø Outgoing)
3Ø4W,
208Y/120 Vac
OR
240/120 Vac
DELTA

1000
1200

1000 A Al
EZM31000CBUei
1200 A Al/Cu EZM31200CBUeg

34.19
34.19

11962.
16215.

3 (Order Lugs Separately)
3 (Order Lugs Separately)

20.46
20.46
20.46

4652.
7576.
10101.

1 (Order Lugs Separately)
2 (Order Lugs Separately)
2 (Order Lugs Separately)

Main Fusible Switches (3Ø Incoming and 3Ø Outgoing)—
Requires 300 Vac Class T Fuses (Order Separately)
3Ø4W
208Y/120 Vac
OR
240/120 Vac
DELTA

400
600
800

800 A Al
800 A Al
800 A Al

EZM3400FSU
EZM3600FSU
EZM3800FSU

Main Lugs Terminal Boxes (3Ø Incoming and 3Ø Outgoing). Supplied with isolated neutral (can not be bonded).c

EZM31600CB

For additional information,
reference Catalog #4100CT9801.
© 2004 Schneider Electric
All Rights Reserved
6/7/04

3Ø4W
208Y/120 Vac
OR
240/120 Vac
DELTA

400
400
800
800
1200
1200

800 A Al
800 A Cu
800 A Al
800 A Cu
1200 A Al/Cu
1200 A Cu

EZM3400TBU
EZM3400TBUCU
EZM3800TBU
EZM3800TBUCU
EZM31200TBUg
EZM31200TBUCU

16.16
16.16
24.16
24.16
32.16
32.16

1225.
1642.
1400.
1875.
2975.
3986.

1 (Order Lugs Separately)
1 (Order Lugs Separately)
2 (Order Lugs Separately)
2 (Order Lugs Separately)
3 (Order Lugs Separately)
3 (Order Lugs Separately)

a For mechanical lugs (3/0 to 600 kcmil) order kit catalog number CMELK4, Price $91.00. Kit includes 4 lugs only.
Multiple kits may be required, consult factory. For crimp-type lugs refer to Anderson Electrical Connector Products
Catalog AEC-40R.
b Has a 100,000 RMS symmetrical ampere short circuit current rating.
c Has a maximum 100,000 RMS symmetrical short circuit current rating when protected by Class R (600 A Max.) or
Class T (800 A Max.) fuses. For other short circuit current ratings refer to table on page 53. Suitable for use on LINE
or LOAD side of service equipment. Use to feed type EZMT branch units for 6-Sub Division Rule applications.
d Does not meet EUSERC requirements. Not stocked in PDS, order only (allow 6 weeks for delivery). Not UL Listed.
e Available by special order with main circuit breaker supplied with other standard ampere ratings, consult your nearest
Square D/Schneider Electric sales office (allow 6 weeks for delivery).
f Ampere rating of the PA circuit breaker supplied with this main can be changed it field by ordering a different set of
rating columns, refer to Digest 173 page 6-25 for listing.
g Supplied with copper horizontal bus bars and aluminum vertical bus bars.
h May be end mounted to feed branch units with 800 A or 1200 A horizontal cross bus.

DE4

Discount
Schedule

47

METERING EQUIPMENT

Main Lugs Terminal Boxes (3Ø Incoming and 3Ø Outgoing)c

Metering
EZ METER-PAK® Meter Centers
Three Phase—Indoor/Rainproof

www.SquareD.com
For the most up-to-date information

3Ø4W EZ Meter-Pak Meter Centers — UL Listed

② Branch Devices—NEMA 3R Construction
Branch Units—3Ø Incoming and 1Ø Outgoing
Width
(Dim.
see pg.
51)

System
Type

Horizontal
Cross Bus
Ratingg
and Bus Bar
Material

Number
of
Meter
Sockets

Ring Type
5-Jaw Meter Socketa
Catalog
Number

Ringless Type
5-Jaw Meter Socket
Catalog
Number

Price

Price

Ringless Type
5-Jaw Meter Socket
with Horn Bypass
Catalog
Price
Number

125 A Maximum (Order Type QO, QO-VH or QOH Circuit Breakers Separately)agd
800 A Al
800 A Cu
800 A Cu
800 A Al
800 A Cu
800 A Cu
800 A Al
800 A Cu
800 A Cu
800 A Al
800 A Cu

3
3Ø4W
208Y/120 Vac
5-Jaw-Meter Socket
2-Pole Branch
Circuit Breakers

4
12.25
5
6

EZML313225

EZM313125
EZM313125M10b
EZM313125CU
EZM314125
EZM314125M10b
EZM314125CU
EZM315125
EZM315125M10b
EZM315125CU
EZM316125
EZM316125CU

$1036.
2835.
1408.
1356.
3780.
1887.
1728.
4725.
2445.
1994.
2844.

EZMR313125
...
EZMR313125CU
EZMR314125
...
EZMR314125CU
EZMR315125
...
EZMR315125CU
EZMR316125
EZMR316125CU

$1036.
...
1408.
1359.
...
1891.
1728.
...
2445.
1994.
2844.

EZMH313125
...
EZMH313125CU
EZMH314125
...
EZMH314125CU
EZMH315125
...
EZMH315125CU
EZMH316125
EZMH316125CU

$1250.
...
1727.
1649.
...
2326.
2074.
...
2964.
2525.
3641.

$1515.
2126.
1861.
2644.
2499.
3602.
3638.
4832.

EZMH312225
EZMH312225CU
EZMH313225
EZMH313225CU
EZMH314225
EZMH314225CU
EZMH315225
EZMH315225CU

$1649.
2326.
2074.
2964.
2765.
4001.
3812.
5128.

225 A Maximum (Order Type QB, QD, QG or QJ Circuit Breakers Separately)aig
2
3Ø4W
208Y/120 Vac
5-Jaw-Meter Socket
2-Pole Branch
Circuit Breakers

3
17.38
4
5

800 A Al
800 A Cu
800 A Al
800 A Cu
800 A Al
800 A Cu
1200 A Al/Cu
1200 A Cu

EZM312225
EZM312225CU
EZM313225
EZM313225CU
EZM314225
EZM314225CU
EZM315225
EZM315225CU

$1515.
2126.
1861.
2644.
2499.
3602.
3280.
4660.

EZMR312225
EZMR312225CU
EZMR313225
EZMR313225CU
EZMR314225
EZMR314225CU
EZMR315225
EZMR315225CU

System
Type

Number of
MeterSockets

METERING EQUIPMENT

225 A Maximum Commercial Branch Units
Horizontal
Cross Bus
Rating
and Bus Bar
Material

Ringless Type
Meter Socket
without Bypass
Catalog
Number

Width
(Dim.
see
pg.
51)

Ringless Type Meter Socket
with Lever Bypass
and Jaw Released
Catalog
Number

Price

Width
(Dim.
see
pg.
51)

Price

Ring Type Meter Socket
with Test Block Bypass.
Meets EUSERC
Requirements
Width
(Dim.
Catalog
see
Price
Number
pg.
51)

3Ø Incoming and 1Ø Outgoinga
(Order Type QB, QD, QG or QJ circuit breakers separately)i
1

EZMT311225

3Ø4W
208Y/120 Vac
5-Jaw
Meter Sockets
2-Pole
Branch
Circuit
Breakers

2
3
4

1200 A Al/Cu
1200 A Al/Cu
1200 A Cu
1200 A Al/Cu
1200 A Al/Cu
1200 A Cu
1200 A Al/Cu
1200 A Al/Cu
1200 A Cu
1200 A Al/Cu

...
...
...
...
...
...
...
...
...
...

...
...
...
...
...
...
...
...
...
...

...
...
...
...
...
...
...
...
...
...

...
EZML312225
EZML312225CU
EZML312225Dd
EZML313225
EZML313225CU
EZML313225Dd
EZML314225
EZML314225CU
EZML314225Dd

...
19.44
19.44
19.44

...
$2844.
4267.
2986.
4280.
6420.
4494.
5821.
8732.
6112.

EZMT311225b
EZMT312225b
...
...
EZMT313225bh
...
...
...
...
...

22.42
22.42
...
...
22.42
...
...

1861.
2791.
1954.
3403.
5105.
3573.
5196.
7795.
5456.
7111.
10666.
7476.

EZMT331225b
...
...
EZMT332225b
...
...
EZMT333225bh
...
...
...
...
...

22.42
...
...
22.42
...
...
22.42
...
...

...

$2363.
4463.
...
...
6694.
...
...
...
...
...

3Ø Incoming and 3Ø Outgoing (Order QB, QD, QG or QJ circuit breakers separately)
3Ø4W
240/120 Vac
DELTA
or
208Y/120 Vac
7-Jaw
Meter Socket
3-Pole
Branch
Circuit
Breakers

EZMT311225
Without Cover

1
2
3
4

1200 A Al/Cu
1200 A Cu
1200 A Al/Cu
1200 A Al/Cu
1200 A Cu
1200 A Al/Cu
1200 A Al/Cu
1200 A Cu
1200 A Al/Cu
1200 A Al/Cu
1200 A Cu
1200 A Al/Cu

...
...
...
EZMR332225
EZMR332225CU
...
EZMR333225
EZMR333225CU
...
EZMR334225
EZMR334225CU
...

...
...
...
19.44
19.44
19.44

...
...
...
$3124.
4686.
...
4891.
7336.
...
6779.
10168.
...

EZML331225
EZML331225CU
EZML331225Dd
EZML332225
EZML332225CU
EZML332225Dd
EZML333225
EZML333225CU
EZML333225Dd
EZML334225
EZML334225CU
EZML334225Dd

19.44
19.44
19.44
19.44

...

2625.
...
...
4638.
...
...
6869.
...
...
...
...
...

a Snap-On aluminum sealing rings supplied as standard.
b Distance between meter sockets as measured from centerline to centerline is 10 inches.
c For 240/120 Vac DELTA Systems add Suffix “CA” to catalog number (Example: EZM314125CA). All meter sockets are phased A and C only. Price remains
the same as the base catalog number. Order only branch units, not stocked in PDS (6-week delivery).
d Supplied with removable drip hood and equipped with an indoor top endwall with knockouts provided.
e Supplied with bondable neutral, suitable for use as service equipment. Use main lugs tap box type EZM-TBU for 6-Sub Division Rule applications to feed this
device. Supplied with copper horizontal bus bars and aluminum vertical bus bars.
f Supplied with Class 320 meter socket.
g For 1200 A main cross bus, add suffix “X” to catalog number. Example: EZMR313125X. Add $147. per device. Allow 6 weeks for delivery.
h Does not meet EUSERC 48" minimum/75" maximum meter height requirements as measured from grade level to centerline on meter. This device measures
37" minimum/75" maximum
i Type QO, QO-VH and QOH branch circuit breakers (40 A–60 A) may be installed with use of EZM125QOA adapter kits, refer to page 50.

For 400 A maximum Commercial Branch Units, see page 49.

For additional information, reference Catalog #4100CT9801.

48

DE4

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Metering
EZ METER-PAK® Meter Centers
Three Phase—Indoor/Rainproof

www.SquareD.com
For the most up-to-date information

3Ø4W EZ Meter-Pak Meter Centers — UL Listed

② Branch Devices—NEMA 3R Construction (Continued)
400 A Maximum Commercial Branch Units

Number
of Meter
Sockets

System
Type

Horizontal
Cross Bus
Rating

Ringless Type Meter Socket with Lever Bypass
and Jaw Release—
400 A Type LAL Branch Circuit Breaker
Included Factory Installed.cd
Catalog Number

Width
(Dim.
see pg.
51)

Price

Ringless Type K Bolt-On Meter Socket with
Manual Bypass—
400 A Type DJM Branch Circuit Breaker
Included Factory Installed. Ampere rating
field adjustable from 160 A–400 A.
Width
(Dim.
Catalog Number
Price
see pg.
51)

3Ø Incoming and 1Ø Outgoinga
3Ø4W
208Y/120 Vac
5-Jaw Meter Socket
2-Pole Branch
Circuit Breakers

1

1200 A Al/Cu
1200 A Cu

2

1200 A Cu

EZML311400b
EZML311400CU
EZML312400b
EZML312400CU

1200 A Al/Cu
1200 A Cu
1200 A Al/Cu
1200 A Cu

EZML331400b
EZML331400CU
EZML332400b
EZML332400CU

23.21
23.21

$ 3987.
5981.
7975.
11963.

...
EZMK311400
...
EZMK312400

...
27.56
...
27.56

...
$ 5949.
...
11689.

4652.
6977.
9304.
13957.

...
EZMK331400
...
EZMK332400

...
27.56
...
27.56

...
$ 7010.
...
13810.

3Ø Incoming and 3Ø Outgoing
3Ø4W
240/120 Vac DELTA
or 208Y/120 Vac
7-Jaw Meter Socket
3-Pole Branch
Circuit Breakers

EZMK311400

1
2

23.21
23.21

EZM Main with Busway Tap
EZ METER-PAK metering equipment is available for use in high rise applications for connection to 800 A–5000 A I-LINE®
or I-LINE II plug-in busway installed as a vertical riser. Three phase only EZM main devices in the form of a main circuit
breaker or main fusible switch are available with an integral busway tap extending from the right or left side of the main
device and phased to align with the busway for either neutral front or neutral back installations.
BUSWAY Mains, three phase only (Indoor only) ordering instructions:

Width
Top of EZM
Mounting
Channel
(See Note)

EZM
Bus Tap

56.11
1425

CL of Busway
Plug-in Opening

Step #1: Determine height to center line of busway plug-in opening, check local utility requirements for minimum and
maximum meter socket heights.
Step #2: Determine side of EZM main section for busway tap to extend from (busway tap is an integral part of the main
and extends to the left or right on the EZM device as viewed from the front).
Step #3: Check phasing of busway riser to insure that it matches phasing of busway tap on main section (indicated as
neutral front or neutral back as viewed from the front).

31.11
4.11

790

104

Floor Level

EZM3800CBNFBTR

Step #4: Select catalog number from tables below.
Step #5: Busway main devices are build to order specials and require 4 to 6 weeks for delivery (order point Lexington).
EZM Mains with Busway Tap (Three Phase Only—note positioning left or right below)
Ampere Width
Rating
(IN)

Width

400
600
800
1000
1200

Neutral Back

Main Fusible Switch with Busway Tapf
Price

Neutral Front

Neutral Back

Price

18.66
18.66
18.66
18.66
30.19

800 A Al
800 A Al
800 A Al
1000 A Al
1200 A Al/Cu

EZM3400CBNFBTR
EZM3600CBNFBTR
EZM3800CBNFBTR
EZM31000CBNFBTRi
EZM31200CBNFBTRgh

EZM3400CBNBBTR
$ 5924. EZM3400FSNFBTR
EZM3600CBNBBTR
8342. EZM3600FSNFBTR
EZM3800CBNBBTR
10496. EZM3800FSNFBTR
EZM31000CBNBBTRi
12861.
...
EZM31200CBNBBTRgh 16929.
...

EZM3400FSNBBTR
EZM3600FSNBBTR
EZM3800FSNBBTR
...
...

$4488.
7093.
9220.
...
...

EZM3400CBNBBTL
EZM3600CBNBBTL
EZM3800CBNBBTL
EZM31000CBNBBTLi
EZM31200CBNBBTLgh

EZM3400FSNBBTL
EZM3600FSNBBTL
EZM3800FSNBBTL
...
...

$4488.
7093.
9220.
...
...

(See Note)

Busway to LEFT of metering equipment lineup

56.11

400
600
800
1000
1200

1425

CL of Busway
Plug-in Opening

31.11
790

Main Circuit Breaker with Busway Tape
Neutral Front

Busway to RIGHT of metering equipment lineup

Top of EZM
Mounting
Channel
EZM
Bus Tap

Horizontal
Cross Bus
Rating

4.11
104

Floor Level

EZM3800FSNBBTL

e
f
g
h
i

18.66
18.66
18.66
18.66
30.19

800 A Al
800 A Al
800 A Al
1000 A Al
1200 A Al/Cu

EZM3400CBNFBTL
EZM3600CBNFBTL
EZM3800CBNFBTL
EZM31000CBNFBTLi
EZM31200CBNFBTLgh

$ 5924. EZM3400FSNFBTL
8342. EZM3600FSNFBTL
10496. EZM3800FSNFBTL
12861.
...
16929.
...

Has a maximum 65,000 RMS symmetrical short circuit current rating.
Has a 100,000 RMS symmetrical ampere short circuit current rating.
Supplied with copper horizontal bus bars and aluminum vertical bus bars.
Requires use of branch units supplied with 1200 A horizontal cross bus.
May be end mounted to feed branch units with 800 A or 1200 A horizontal cross bus.

Note: Dimensions shown will position the centerline of top meter socket of a 125 A, 5-Gang or 6-Gang branch unit at 72" above floor level. Check with utility to
meet local requirements.

For additional information, reference Catalog #4100CT9801.
© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE4

Discount
Schedule

49

METERING EQUIPMENT

a For 240/120 Vac DELTA Systems add Suffix “CA” to catalog number (Example: EZML312400CA). All meter sockets are phased A and C only. Price remains
the same as the base catalog number. “Order only” branch units, not stocked in PDS (4–6 week delivery). Order point Lexington.
b Supplied with copper horizontal bus bars and aluminum vertical bus bars.
c Device has limited short circuit current rating, refer to page 53.
d Supplied with Class 320 meter socket.

Metering
EZ METER-PAK® Meter Centers
Tenant Circuit Breakers and Accessories

www.SquareD.com
For the most up-to-date information

③ Tenant Circuit Breakers
Poles

10 kA AIR

Ampere
Rating

22 kA AIR

Cat. No.

Price

42 kA AIR

Cat. No.

Price

100 kA AIR

Cat. No.

Price

Cat. No.

Price

$ 211.00
211.00
211.00
352.00
434.00

...
...
...
...
...

...
...
...
...
...

434.00
434.00
926.00
926.00

...
...
...
...

...
...
...
...

125 A Max. EZM Branch Unit Tenant Circuit Breakers

QO2100VH
2-Pole, Plug-on Type
Circuit Breaker

2

40
50
60
70
80

QO240
QO250
QO260
QO270
QO280

90
100
110
125

QO290
QO2100
QO2110
QO2125

$

44.70
44.70
44.70
89.00
126.00

QO240VH
QO250VH
QO260VH
QO270VH
QO280VH

$

126.00
126.00
285.00
285.00

QO290VH
QO2100VH
QO2110VH
QO2125VH

97.00
97.00
97.00
149.00
210.00

QOH240
QOH250
QOH260
QOH270
QOH280

210.00
210.00
689.00
689.00

QOH290
QOH2100
QOH2110
QOH2125

97.00
97.00
97.00
762.00
762.00

QOH240b
QOH250b
QOH260b
QGP22070TM
QGP22080TM

$ 211.00
211.00
211.00
1014.00
1014.00

...
...
...
QJP22070TM
QJP22080TM

...
...
...
$1260.00
1260.00

225 A Max. EZM Branch Unit Tenant Circuit Breakers
10 kA AIR

2

QDP22200TM
2-Pole, Bolt-on Type
Circuit Breaker

METERING EQUIPMENT

3

For additional information,
reference Catalog
#4100CT9801.

④ Accessories

40
50
60
70
80

QO240
QO250
QO260
QBP22070TM
QBP22080TM

90
100
125
150
175

25 kA AIR
$

$

100 kA AIR

QO240VHa
QO250VHa
QO260VHa
QDP22070TM
QDP22080TM

QBP22090TM
QBP22100TM
QBP22125TM
QBP22150TM
QBP22175TM

316.00
316.00
316.00
316.00
316.00

QDP22090TM
QDP22100TM
QDP22125TM
QDP22150TM
QDP22175TM

762.00
762.00
762.00
762.00
762.00

QGP22090TM
QGP22100TM
QGP22125TM
QGP22150TM
QGP22175TM

1014.00
1014.00
1014.00
1014.00
1014.00

QJP22090TM
QJP22100TM
QJP22125TM
QJP22150TM
QJP22175TM

1260.00
1260.00
1260.00
1260.00
1260.00

200
225

QBP22200TM
QBP22225TM

316.00
316.00

QDP22200TM
QDP22225TM

762.00
762.00

QGP22200TM
QGP22225TM

1014.00
1014.00

QJP22200TM
QJP22225TM

1260.00
1260.00

70
80
90
100
125

QBP32070TM
QBP32080TM
QBP32090TM
QBP32100TM
QBP32125TM

$ 832.00
832.00
832.00
832.00
832.00

QDP32070TM
QDP32080TM
QDP32090TM
QDP32100TM
QDP32125TM

$1189.00
1189.00
1189.00
1189.00
1189.00

QGP32070TM
QGP32080TM
QGP32090TM
QGP32100TM
QGP32125TM

$1628.00
1628.00
1628.00
1628.00
1628.00

QJP32070TMc
QJP32080TMc
QJP32090TMc
QJP32100TMc
QJP32125TMc

$1864.00
1864.00
1864.00
1864.00
1864.00

150
175
200
225

QBP32150TM
QBP32175TM
QBP32200TM
QBP32225TM

832.00
832.00
832.00
832.00

QDP32150TM
QDP32175TM
QDP32200TM
QDP32225TM

1189.00
1189.00
1189.00
1189.00

QGP32150TM
QGP32175TM
QGP32200TM
QGP32225TM

1628.00
1628.00
1628.00
1628.00

QJP32150TMc
QJP32175TMc
QJP32200TMc
QJP32225TMc

1864.00
1864.00
1864.00
1864.00

a QO-VH tenant circuit breaker is rated 22 kA AIR max.
b QOH tenant circuit breaker is rated 42 kA AIR max.
c 3-pole QJP tenant circuit breaker is rated 65 kA AIR max. at 240/120 Vac, 3-Phase, 4-Wire High Leg DELTA, or 100kA AIR max. at 208Y/120 Vac, 3-Phase,
4-Wire.

Description
FIFTH JAW KIT (1 per kit)
Secondary Surge Arrester Mounting Kit
For use with 1 or 2-SDSA1175 or 1-SDSA3650
(order surge arrester separately)
Transition Section, 1200 A (10.7" wide)
Add right of old style 1Ø EZM lineup
Add right of old style 3Ø EZM lineup
Add left of old style 1Ø EZM lineup
Add left of old style 3Ø EZM lineup
1200 A 1Ø3W BUSSED EXTENSION
(Indoor/Outdoor)
1200 A 1Ø3W BUSSED CORNER for INSIDE CORNER
(NEMA 1 indoor only)
1200 A 3Ø4W BUSSED EXTENSION
(Indoor/Outdoor)
1200 A 3Ø4W BUSSED CORNER for INSIDE CORNER
(NEMA 1 indoor only)
1200 A, 1-Phase, 3-Wire BUSSED ELBOW for OUTSIDE
CORNER (NEMA 1 indoor only)
1200 A, 3-Phase, 4-Wire BUSSED ELBOW for OUTSIDE
CORNER (NEMA 1 indoor only)
Stud Kit for 400 A TAP BOX includes (2) 1/2"-13 studs per
pad and mounting hardware. Four pads per kit.
Stud Kit for 800 A TAP BOX includes (4) 1/2"-13 studs per
pad and mounting hardware. Four pads per kit.
LEXAN METER SOCKET CLOSING PLATE
Not for use on commercial sockets.
Q2 CIRCUIT BREAKER CLOSING PLATE
MOUNTING CHANNEL (72" long)
METAL CLOSING PLATE
For use only on Type EZML and EZMR (3Ø IN-3Ø OUT)
branch units.
SEALING RINGS:
SNAP-ON (Stainless Steel)
SCREW-Type (Aluminum)
LATCH-Type (Aluminum)-standard
HORN BYPASS KIT
(use with type EZMR 1Ø meter socket only)
BARREL LOCK KIT
For use on ringless EZM or MP branch unit covers,
includes 6 each of head protectors, lock nuts and sealing
caps. (Barrel lock not included.)
QO ADAPTER for BOLT-ON Q-frame
Tenant Circuit Breakers (40–60 A, 2-Pole)
EQUIPMENT GROUND TERMINAL

④ Accessories (Continued)

Catalog Number
5Jd
MMSAMKe

Price
$ 12.20
53.00

EZM1TRANR
EZM3TRANR
EZM1TRANL
EZM3TRANL

158.00
168.00
210.00
221.00

EZM1EXT

511.00

EZM1CORNER
EZM3EXT

1192.00
644.00

EZM3CORNER

1478.00

EZM1ELBOW

1192.00

EZM3ELBOW

1478.00

EZMSK2

164.00

EZMSK4

328.00

Description
SLIDER TYPE MANUAL CIRCUIT CLOSER
(for one Ring Type socket only):
125–200 A (Indoor/Outdoor)
ANTI-INVERSION CLIP
Rejects use of 100 A and 200 A meters in Class 320
meter sockets in Type EZML branch units.
Al/Cu Lug Kits (Each kit includes three, 2-barrel lugs.)
(1) #1/0–600 kcmil or (2) #1/0–250 kcmil per lug
(2) #3/0–500 kcmil per lug
(2) #2–600 kcmil per lug

Catalog Number

Price

MM200MBfg

114.00

59676

MMLK250
MMLK500
MMLK600

EZM busway transition section provides no overcurrent protection for the
downstream EZM branch units. Tenant main circuit breakers in these
branch units must be selected as “fully rated” equipment. (Examples:
QO for 10 kA, QO-VH for 22 kA or QOH for 42 kA.)

7.40
42.00

RSG4

81.00

16.11

409
Width

409
Width

4.11

6.70

EZMPCP
EZM72MC

4.11

104

104

EZM
Bus Tap
Top of EZM
Mounting
Channel

11.10
13.40
5.00

MMHB

11.10

MMBLC

44.10

EZM
Bus Tap

1.00

1.00

55.11

55.11

25

Top of EZM
Mounting
Channel

25

CL of Busway
Plug-in Opening

CL of Busway
Plug-in Opening

56.11

ARP00026
29008W
2920910001

100.00
133.00
155.00

Busway Transition Section

16.11

29007

5.30

d All sockets include 5th Jaw Factory installed except EZM11__ devices.
e Consult your nearest Square D/Schneider Electric sales office for details.
f Meter center short circuit current rating is 10,000 RMS symmetrical amperes with manual
circuit closers installed (bypass is not designed for use as continuous duty).
g For use on ring type meter sockets only.

1425

1400

56.11

1400

Floor Level

1425

Floor Level

EZM3BUSRF and EZM3BUSRB

EZM3BUSLF and EZM3BUSLB

EZM Busway Transition Sections (three phase only)
Ampere Rating

Neutral Front

Neutral Back

Width (IN)

Price

I-LINE® Busway located on RIGHT side of EZM Transition Section
EZM125QOA
....

182.00
Included

1200

DE2A

EZM3BUSRF

EZM3BUSRB

12.00

$2625.

I-LINE Busway located on LEFT side of EZM Transition Section
1200

50

65 kA AIR

44.70
44.70
44.70
316.00
316.00

Discount
Schedule

EZM3BUSLF

EZM3BUSLB

12.00

2625.

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Metering
EZ METER-PAK® Meter Centers
Dimensions

www.SquareD.com
For the most up-to-date information

Branch Devices
Width
(W)

Depth
(D)

53.97
70.05
61.19
70.05
61.19
70.05
51.58
44.71
61.19
71.19
51.58
21.81
53.97
69.03
53.97
69.03
28.43
35.71
53.97
69.03
53.97
69.03
28.43
53.97
69.03
53.97
69.03
51.76
39.96
19.34

18.66
34.19
30.19
34.19
30.19
34.19
22.33
33.16
30.19
30.19
22.33
11.50
18.66
20.46
18.66
20.46
17.00
17.16
18.66
20.46
18.66
20.46
17.00
18.66
20.46
18.66
20.46
23.93
25.06
11.66

11.50
18.33
18.33
18.33
18.33
18.33
13.00
11.12
18.33
18.33
13.00
5.81
11.50
11.50
11.50
11.50
6.53
8.00
11.50
11.50
11.50
11.50
6.53
11.50
11.50
11.50
11.50
6.41
11.12
6.37

Mtg.
Channel
(MC)
34.30
46.99
38.13
46.99
38.13
46.99
27.92
31.17
38.13
48.12
27.92
13.00c
34.30
49.37
34.30
49.37
16.29
27.17
34.30
49.37
34.30
49.37
16.29
34.30
49.37
34.30
49.37
28.01
31.17
11.85c

19.50

14.40

8.02

11.85c

19.50

14.52

8.01

11.85c

53.97
70.05
61.19
70.05
51.58
44.71
61.19
71.19
51.58
21.81
53.97
69.03
53.97
69.03
28.43
35.71
53.97
69.03
53.97
69.03
28.43
53.97
69.03
53.97
69.03
51.76
39.96
19.34

18.66
34.19
30.19
34.19
22.33
33.16
30.19
30.19
22.33
11.50
18.66
20.46
18.66
20.46
17.00
17.16
18.66
26.19
18.66
26.19
17.00
18.66
26.19
18.66
26.19
23.93
25.06
11.66

11.50
18.33
18.33
18.33
13.00
11.12
18.33
18.33
13.00
5.81
11.50
11.50
11.50
11.50
6.53
8.00
11.50
11.65
11.50
11.65
6.53
11.50
11.65
11.50
11.65
6.41
11.12
6.37

34.30
46.99
38.13
46.99
27.92
31.17
38.13
48.12
27.92
13.00c
34.30
49.37
34.30
49.37
16.29
27.17
34.30
49.37
34.30
49.37
16.29
34.30
49.37
34.30
49.37
28.01
31.17
11.85c

19.50

14.40

8.02

11.85c

19.500

14.52

8.01

11.85c

Height
(H)

Catalog Number
EZM11000CB
EZM11000CBU
EZM11200CB
EZM11200CBU
EZM11200FS
EZM11200FSU
EZM11200TB [CU]
EZM11200TBU [CU]
EZM11600CB
EZM11600CBU
EZM11600TB [CU]
EZM1225TB [CU]
EZM1400CB
EZM1400CBU
EZM1400FS
EZM1400FSU
EZM1400TB [CU]
EZM1400TBU [CU]
EZM1600CB
EZM1600CBU
EZM1600FS
EZM1600FSU
EZM1600TB [CU]
EZM1800CB
EZM1800CBU
EZM1800FS
EZM1800FSU
EZM1800TB [CU]
EZM1800TBU [CU]
EZM1EXT
EZM1CORNER
(indoor only)a
EZM1ELBOW
(indoor only)b
EZM31000CB
EZM31000CBU
EZM31200CB
EZM31200CBU
EZM31200TB [CU]
EZM31200TBU [CU]
EZM31600CB
EZM31600CBU
EZM31600TB [CU]
EZM3225TB [CU]
EZM3400CB
EZM3400CBU
EZM3400FS
EZM3400FSU
EZM3400TB [CU]
EZM3400TBU [CU]
EZM3600CB
EZM3600CBU
EZM3600FS
EZM3600FSU
EZM3600TB [CU]
EZM3800CB
EZM3800CBU
EZM3800FS
EZM3800FSU
EZM3800TB [CU]
EZM3800TBU [CU]
EZM3EXT
EZM3CORNER
(indoor only)a
EZM3ELBOW
(indoor only)b

a Each leg of this corner section measures 14.72" from wall to start of next
enclosure.
b Each leg of elbow section measures 6.17" corner of wall to start of next
enclosure.
c Device supplied without mounting channel, secure to wall by use of
swingable mounting feet.
d Standard branch units are available without suffix added.
W

W

H

MC (Mounting Channel)

MC (Mounting Channel)

T

H

B

Branch Device

For additional information,
reference Catalog #4100CT9801.
© 2004 Schneider Electric
All Rights Reserved
6/7/04

Main Device

Catalog Number
[available suffix]

Height
(H)

Width
(W)

Depth
(D)

Mtg.
Channel
(MC)

Top
Meter
(T)

Bottom
Meter
(B)

43.41
42.37
43.41
48.12
52.00
57.12
61.00
66.12
43.41
42.37
43.41
48.12
52.00
57.12
61.00
66.12
45.55
72.99
39.06
39.06
44.55
39.06
39.06
69.61
53.06
53.06
67.06
67.06
43.41
42.37
43.41
48.12
52.00
57.12
61.00
66.12
25.45
60.56
79.56

17.38
12.25
17.38
12.25
17.38
12.25
17.38
12.25
17.38
12.25
17.38
12.25
17.38
12.25
17.38
12.25
27.56
27.56
19.44
19.44
23.21
19.44
19.44
23.21
19.44
19.44
19.44
19.44
17.38
12.25
17.38
12.25
17.38
12.25
17.38
12.25
22.42
22.42
22.42

8.09
7.09
8.09
7.09
8.09
7.09
8.09
7.09
8.09
7.09
8.09
7.09
8.09
7.09
8.09
7.09
9.74
9.74
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
8.09
7.09
8.09
7.09
8.09
7.09
8.09
7.09
9.38
9.38
9.38

32.34
31.30
32.34
31.30
32.34
31.30
40.03
40.30
32.34
31.30
32.34
31.30
32.34
31.30
40.03
40.30
37.81
37.81
25.51
25.51
37.81
25.51
25.51
37.81
39.51
39.51
39.51
39.51
32.34
31.30
32.34
31.30
32.34
31.30
40.03
40.30
16.19
43.63
48.25

22.18
13.18
13.18
9.93
12.77
9.93
12.77
9.93
22.18
13.18
13.18
9.93
12.77
9.93
12.77
9.93
24.51
22.26
25.67
25.67
24.02
11.67
11.67
20.64
11.67
11.67
11.67
11.67
22.18
13.18
13.18
9.93
12.77
9.93
12.77
9.93
4.67
12.67
12.67

12.23
11.19
12.23
11.19
12.23
11.19
12.23
11.19
12.23
11.19
12.23
11.19
12.23
11.19
12.23
11.19
21.04
21.04
13.39
13.39
21.53
13.39
13.39
21.53
13.39
13.39
13.39
13.39
12.23
11.19
12.23
11.19
12.23
11.19
12.23
11.19
20.45
28.89
28.89

43.41
42.37
42.37
43.41
48.12
52.12
52.00
57.12
62.12
61.00
66.12
43.41
42.37
43.41
48.12
52.00
57.12
61.00
66.12
45.55
72.99
45.55
72.99
45.55
39.06
39.06
39.06
69.61
53.06
53.06
67.06
67.06
39.06
39.06
45.55
39.06
39.06
69.61
53.06
53.06
67.06
67.06
43.41
42.37
43.41
48.12
52.00
57.12
61.00
66.12
39.06
53.06
67.06
25.45
60.56
79.56
25.12
60.56
79.56

17.38
12.25
12.25
17.38
12.25
12.25
17.38
12.25
12.25
17.38
12.25
17.38
12.25
17.38
12.25
17.38
12.25
17.38
12.25
27.56
27.56
27.56
27.56
23.21
19.44
19.44
19.44
23.21
19.44
19.44
19.44
19.44
19.44
19.44
23.21
19.44
19.44
23.21
19.44
19.44
19.44
19.44
17.38
12.25
17.38
12.25
17.38
12.25
17.38
12.25
19.44
19.44
19.44
22.42
22.42
22.42
22.42
22.42
22.42

8.09
7.09
7.09
8.09
7.09
7.09
8.09
7.09
7.09
8.09
7.09
8.09
7.09
8.09
7.09
8.09
7.09
8.09
7.09
9.74
9.74
9.74
9.74
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
9.44
8.09
8.09
8.09
7.09
8.09
7.09
8.09
7.09
9.44
9.44
9.44
9.38
9.38
9.38
9.38
9.38
9.38

32.34
31.30
24.29
32.34
31.30
34.29
32.34
31.30
34.29
40.03
40.30
32.34
31.30
32.34
31.30
32.34
31.30
40.03
40.30
30.60
37.81
30.60
37.81
37.81
25.51
25.51
25.51
37.82
39.51
39.51
39.51
39.51
25.51
25.51
37.81
35.51
35.51
37.82
39.51
39.51
39.51
39.51
32.34
31.30
32.34
31.30
32.34
31.30
40.03
40.30
25.51
39.51
39.51
16.19
43.63
48.25
16.19
43.63
48.25

22.18
13.18
10.18
13.18
9.93
9.93
12.77
9.93
9.93
12.77
9.93
22.18
13.18
13.18
9.93
12.77
9.93
12.77
9.93
24.51
22.26
24.51
22.26
24.02
25.67
11.67
11.67
20.64
11.67
11.67
11.67
11.67
25.67
25.67
24.02
11.67
11.67
20.64
11.67
11.67
11.67
11.67
22.18
13.18
13.18
9.93
12.77
9.93
12.77
9.93
11.67
11.67
11.67
4.67
12.67
12.67
4.67
12.67
12.67

12.23
11.19
12.19
12.23
11.19
12.19
12.23
11.19
12.19
12.23
11.19
12.23
11.19
12.23
11.19
12.23
11.19
12.23
11.19
21.04
21.04
21.04
21.04
21.53
13.39
13.39
13.39
21.53
13.39
13.39
13.39
13.39
13.39
13.39
21.53
13.39
13.39
21.53
13.39
13.39
13.39
13.39
12.23
11.19
12.23
11.19
12.23
11.19
12.23
11.19
13.39
13.39
13.39
20.45
28.89
28.89
20.45
28.89
28.89

Single Phased
EZM112225 [X, CU, CUX]
EZM113125 [X, CU, CUX]
EZM113225 [X, CU, CUX]
EZM114125 [X, CU, CUX]
EZM114225 [X, CU, CUX]
EZM115125 [X, CU, CUX]
EZM115225 [X, CU, CUX]
EZM116125 [X, CU, CUX]
EZMH112225 [X, CU, CUX]
EZMH113125 [X, CU, CUX]
EZMH113225 [X, CU, CUX]
EZMH114125 [X, CU, CUX]
EZMH114225 [X, CU, CUX]
EZMH115125 [X, CU, CUX]
EZMH115225 [X, CU, CUX]
EZMH116125 [X, CU, CUX]
EZMK111400
EZMK112400
EZML111225 [CU]
EZML111225D
EZML111400 [CU]
EZML112225 [CU]
EZML112225D
EZML112400 [CU]
EZML113225 [CU]
EZML113225D
EZML114225 [CU]
EZML114225D
EZMR112225 [X, CU, CUX]
EZMR113125 [X, CU, CUX]
EZMR113225 [X, CU, CUX]
EZMR114125 [X, CU, CUX]
EZMR114225 [X, CU, CUX]
EZMR115125 [X, CU, CUX]
EZMR115225 [X, CU, CUX]
EZMR116125 [X, CU, CUX]
EZMT111225
EZMT112225
EZMT113225

Three Phased
EZM312225 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZM313125 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZM313125M10
EZM313225 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZM314125 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZM314125M10
EZM314225 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZM315125 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZM315125M10
EZM315225 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZM316125 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMH312225 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMH313125 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMH313225 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMH314125 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMH314225 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMH315125 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMH315225 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMH316125 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMK311400 [CA]
EZMK312400 [CA]
EZMK331400 [CA]
EZMK332400 [CA]
EZML311400 [CU, CA, CUCA]
EZML311225 [CU, CA, CUCA]
EZML312225 [CU, CA, CUCA]
EZML312225D [CA]
EZML312400 [CU, CA, CUCA]
EZML313225 [CU, CA, CUCA]
EZML313225D [CA]
EZML314225 [CU, CA, CUCA]
EZML314225D [CA]
EZML331225 [CU]
EZML331225D
EZML331400 [CU]
EZML332225 [CU]
EZML332225D
EZML332400 [CU]
EZML333225 [CU]
EZML333225D
EZML334225 [CU]
EZML334225D
EZMR312225 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMR313125 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMR313225 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMR314125 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMR314225 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMR315125 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMR315225 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMR316125 [X, CU, CUX, CA, XCA, CUCA, CUXCA]
EZMR332225 [CU]
EZMR333225 [CU]
EZMR334225 [CU]
EZMT311225 [CA]
EZMT312225 [CA]
EZMT313225 [CA]
EZMT331225
EZMT332225
EZMT333225

51

METERING EQUIPMENT

Main Devices

Metering
EZ METER-PAK® Meter Centers
Indoor/Rainproof

www.SquareD.com
For the most up-to-date information

240 Vac Maximum, NEMA 3R Construction Meter Centers for use on AC-Systems. Suitable for use as Service
Equipment.
Utility Company Requirements: Review local utility requirements to
Main Devices:

METERING EQUIPMENT

ensure that metering equipment meets their standards.
EZ METER-PAK meter center enclosures meet NEC wire bending
requirements, and are designed for wall mounting only (not suitable for
floor mounting). All unmetered conductor compartments are sealable by
the utility company.
EZ METER-PAK meter centers have UL Listed short circuit current
ratings up to 100,000 RMS symmetrical amperes at 240 Vac when
properly applied. Refer to table below for details and appropriate
downstream load centers and panelboards.
Suitable incoming services for an EZM main device and available
outgoing feeder(s) to downstream panelboards from EZM branch
section(s):
Incoming Service to Main Device 120/240 Vac, 1Ø3W:
Available outgoing feeder(s) to downstream panelboards:
• 120/240 Vac, 1Ø3W
(4-jaw ring type meter sockets, 2-pole circuit breakers)
(5-jaw ringless meter sockets, 2-pole circuit breakers)
Incoming Service to Main Device 240/120 Vac, 3Ø4W Delta:
Available outgoing feeder(s) to downstream panelboards:
• 120/240 Vac, 1Ø3W
(Fed from transformer’s “A-Phase” and “C-Phase” only.) NOTE:
Connection to High-Leg “B-Phase” not permitted for this service
(4-jaw ring type meter sockets, 2-pole circuit breakers)
(5-jaw ringless meter sockets, 2-pole circuit breakers)
Standard 3-Phase IN/1-Phase OUT branch units are not suitable
for use on this DELTA System. Special branch units are available
for this System by adding suffix: “CA” to catalog number (Typical
Examples: EZM313125CA, EZMH314200CA, etc.).
• 240/120 Vac, 3Ø4W Delta
(7-jaw meter sockets, 3-pole circuit breakers)
Incoming Service to Main Device 208Y/120 Vac, 3Ø4W:
Available outgoing feeder(s) to downstream panelboards:
• 120/208 Vac, 1Ø3W
(5-jaw meter sockets, 2-pole circuit breakers)
• 208Y/120 Vac, 3Ø4W
(7-jaw meter sockets, 3-pole circuit breakers)

• 1200 A main disconnect or terminal box must be center mounted
when used with branch devices with main bus rated 800 A.
• 1600 A main disconnect or terminal box must be center mounted.
• 400, 800 and 1200 A type EZM-TBU tap boxes supplied with lug
landings to meet EUSERC requirements.
Main Circuit Breaker, ratings: 400, 600, 800, 1000, 1200, and 1600 A
Main Fusible Switch, ratings: 400, 600, 800, and 1200 A (1 phase, 3
wire only)
Main Lugs Terminal Box, ratings: 225 A, 400, 600, 800, 1200, and
1600 A

Branch Unit:
• 125 A and 225 A residential branch units, available in ring or
ringless type construction and supplied with 800 A horizontal
cross bus. For all-copper bussing, add suffix “CU” to catalog
number (Example: EZM314125CU). Plug-in style meter sockets
are available as ring type EZM without bypass, ringless type EZMR
without bypass, and ringless type EZMH with horn bypass. For
1200 A main cross bus, add suffix “X” to catalog number
(Example: EZM314125X).
• 225 A commercial branch units, available in ring or ringless type
construction and supplied with 1200 A horizontal cross bus. For
all-copper bussing, add suffix “CU” to catalog number (Example:
EZML334200CU). Plug-in style meter sockets are available as
ringless type EZMR without bypass, ringless type EZML with lever
bypass and ring type EZMT with test block bypass (meets
EUSERC requirements).
• 400 A branch units, Type EZML branch units are available in
ringless type construction, supplied with 1200 A AL/CU
(standard), or 1200 A copper (add suffix “CU” ) horizontal cross
bus. This plug-in meter socket is supplied with lever bypass and
jaw release. Type EZMK branch units are supplied with 1200 A
copper (standard) horizontal cross bus. This bolt-on meter socket
is supplied with a manual bypass.
• Units having 800 A horizontal cross bus WILL CONNECT with
units having 1200 A horizontal cross bus.
• Single Phase units (three bus bars in horizontal cross bus) WILL
NOT CONNECT with three phase units (four bus bars in
horizontal cross bus).

Square D Certified Ratings for Downstream Panelboards:a
For load centers or panelboards installed downstream from
any UL Listed MP METER-PAK (single phase only)
or EZ METER-PAK meter center applied on a system
capable of delivering greater than 10,000 RMS symmetrical
amperes. Requires a minimum of 20 feet of cable between
meter center and downstream load center or panelboard.
all ratings verified by actual Square D tests.

QO Load Centers or NQOD Panelboards with
Branch Circuit Breakers rated 10,000 AIR

HOM Load Centers with Branch
Circuit Breakers rated 10,000
AIR

Downstream
Single Phase Load Center
or Panelboard

QO, QOB – 1-Pole (15 A–70 A)
QOT–1-Pole (15 A–70 A)
QO-GFI, QOB-GFI–1-Pole (15 A–30 A)
QO-AFI, QOB-AFI–1-Pole (15 A–20A)
QO, QOB–2-Pole (15 A–125 A)

HOM–1-Pole (15 A–50 A)
HOMT–1-Pole (15 A–20 A)
HOM-AFI–1-Pole (15A–20A)
HOM-GFI–1-Pole (15 A–20 A)
HOM–2-Pole (15 A–70 A)
HOMT–2-Pole (15 A–30 A)

Downstream
Three Phase Load Center
or Panelboard

QO, QOB– 1-Pole (15 A–70 A)
2-Pole (15 A–125 A)
3-Pole (15 A–100 A)
QO-AFI, QOB-AFI–1-Pole (15 A–20 A)
QO-GFI, QOB-GFI–1-Pole (15 A–30 A)

Meter Center 125 A and
225 A Branch Units

...

a For additional information, refer to Data Bulleting #4100DB0301.

For additional information, reference Catalog #4100CT9801.

52

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Metering
EZ METER-PAK® Meter Centers
Short Circuit Current Ratings

www.SquareD.com
For the most up-to-date information

• Review local utility
requirements to ensure
that metering equipment
meets their standards.
• Check local utility to
determine available fault
current at the meter center.
• Using the SCCR table:
— Select meter center
configuration, main lugs
only (6-Subdivision
Rule), or remote main,
main circuit breaker, or
main fusible switch.
— Read down to select
SCCR equal to, or
greater than desired
rating.
— Read across to select
branch unit tenant
circuit breaker type.
— Continue reading
across to select EZM
main device type.
• With information obtained
from table below, turn to
appropriate selection/
pricing pages to determine
catalog numbers for main
device, branch units, and
tenant circuit breakers to
complete meter center.

UL Listed Meter Center Short Circuit Current Ratings (SCCR)
EZM Meter Center Overcurrent Protection Devices
Short Circuit
Current Rating
EZM Branch Unit Tenant Circuit Breaker
EZM Main Device
(RMS Symmetrical
Types Available
with Integral Mounted Main,
Amperes at
(Branch Unit Amperes max., Number of
Remote Mounted Main or
240 Vac
Poles, Tenant Circuit Breaker Amperes
without an Upstream Mounted Main
Maximum)ab
Rating Range)
(6-Sub-Division Rule)

EZ METER-PAK (6-Subdivision Rule Applications)—See Figure 1
10,000
18,000
22,000
25,000
42,000
65,000
100,000

10,000

QO (125 A, 2-Pole, 40–125 A)
QO (225 A, 2-Pole, 40–125 A)e
QB (225 A 2 or 3-Pole, 70–225 A)

225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 10,000 AIR minimum

18,000

LAL (400 A, 2 or 3-Pole, 125–400 A)e

22,000

QO-VH (125 A, 2-Pole, 40–125 A)
QO-VH (225 A, 2-Pole, 40–60 A)e

225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 18,000 AIR minimum
225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 22,000 AIR minimum
225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 25,000 AIR minimum
225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 42,000 AIR minimum

25,000

QD (225 A 2 or 3-Pole, 70–225 A)

42,000

QOH (125 A, 2-Pole, 40–125 A)
QOH (225 A, 2-Pole, 40–60 A)e
QO-VH (125 A, 2-Pole, 40–125 A)
QO-VH (225 A, 2-Pole, 40–60 A)e
QD (225 A 2 or 3-Pole, 70–225 A)
DJM (400 A, 2 or 3-Pole,160–400 A)f

65,000

Load
Centers
(Main Lugs)

225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 65,000 AIR minimum

QO-VH (125 A, 2-Pole, 40–125 A)
QO-VH (225 A, 2-Pole, 40–60 A)e
QD (225 A 2 or 3-Pole, 70–225 A)
DJM (400 A, 2 or 3-Pole, 160–400 A)f

225–1600 A Main Lugs Terminal Box Must be protected by a Square D Circuit Breaker
Type LH (400 A max.), MH (1000 A max.) or PA (1600 A max.) Rated 65,000 AIR
minimum

QJ (225 A 2-Pole only, 70–225 A )
QJ (225 A 3-Pole only, 70–225 A)
QO-VH (125 A, 2-Pole, 40–125 A)
QO-VH (225 A, 2-Pole, 40–60 A)e
DJM (400 A, 2 or 3-Pole, 160–225 A)f
QD (225 A 2-Pole only, 70–225 A)
QD (225 A 3-Pole only, 70–225 A)c

Service
Disconnects
(6 Max.)

225–1600 A Main Lugs Terminal Box Must be protected by a Square D Circuit Breaker
Type LA (400 A max.) or MA (800 A max.) Rated 42,000 AIR minimum

QG (225 A 2 or 3-Pole, 70–225 A)

QD (225 A 2 or 3-Pole, 70–225 A)

100,000

Transformer

225–1600 A Main Lugs Terminal Box
(Tenant Circuit Breakers used as Service Disconnects—6 maximum)

EZ METER-PAK—Main Lugs Terminal Box Applications Protected By Remote Main—See Figure 2

• Refer to “Square D
Certified Ratings” table on
page 52 to determine
suitable downstream load
centers or panelboards.
EZM Branch Units

QO (125 A, 2-Pole, 40–125 A)
QO (225 A, 2-Pole, 40–125 A)e
QB (225 A, 2 or 3-Pole, 70–225 A)
LAL (400 A, 2 or 3-Pole, 125–400 A)e
QO-VH (125 A, 2-Pole, 40–125 A )
QO-VH (225 A, 2-Pole, 40–60 A)e
QD (225 A, 2 or 3-Pole, 70–225 A)
QOH (125 A, 2-Pole, 40–125 A)
QOH (225 A, 2-Pole, 40–60 A)e
QG (225 A, 2 or 3-Pole, 70–225 A)
QJ (225 A, 2-Pole only, 70–225 A)
QJ (225 A, 3-Pole only, 70–225 A) c
DJM (400 A, 2 or 3-Pole, 160–400 A)f

225–1600 A Main Lugs Terminal Box Must be protected by a Square D Circuit Breaker
Type MG (800 A max.), PG (1200 A max.) or RG (1600 A max.) Rated 65,000 AIR
minimum
225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 100,000 AIR minimum
Must be protected by an Upstream Disconnection Means with Class R (600 A max.),
or Class T (300 Vac, 800 A maximum) fuses.
Must be protected by an Upstream Disconnection Means with Class J (600 A max.),
Class L (1200 A max.), Class R (600 A max.), Class T (300 Vac, 1200 A max.) or
Class T (600 Vac, 800 A maximum) fuses. Or be protected by a Square D circuit
breaker Type MJ (800 A max.), PJ (1200 A max.), PH (1600 A max.) or RJ (1600 A
max.) Rated 100,000 AIR minimum.

EZ METER-PAK—Main Circuit Breaker Applications—See Figure 3
EZM Main Lugs Terminal Box

10,000
Figure 1

18,000

EZM Main Lugs Terminal Box
EZM Branch Units

65,000

100,000
Transformer

Tenant
Circuit
Breakers

Load
Centers
(Main Lugs)

Upstream Disconnection
Means and Overcurrent
Protection as required

Figure 2

10,000

42,000

EZM Branch Units

65,000
100,000
100,000

Transformer
Tenant
Circuit
Breakers

Figure 3

Load
Centers
(Main Lugs)

400–1600 A EZM Main Device with Type LH (400 A max.), MH (1000 A max.) or PA
(1600 A max.) Circuit Breaker.

1000–1200 A Main Device with Catalog Number Suffix "CBU" supplied with Type
MHF Circuit Breaker.

EZ METER-PAK—Main Fusible Switch Applications—See Figure 3

18,000
EZM Circuit Breaker Main
or EZM Main Fusible Switch

QO (125 A, 2-Pole, 40–125 A)
QO (225 A, 2-Pole, 40–125 A)e
QB (225 A 2 or 3-Pole, 70–225 A)
LAL (400 A, 2 or 3-Pole, 120–400 A)e
QO-VH (125 A, 2-Pole, 40–125 A)
QO-VH (225 A, 2-Pole, 40–60 A)e
QD (225 A 2 or 3-Pole, 70–225 A)
DJM (400 A, 2 or 3-Pole, 160–400 A)
QO-VH (125 A, 2-Pole, 40–125 A)
QO-VH (225 A, 2-Pole, 40–60 A)e
QD (225 A 2-Pole only, 70–225 A)
QD (225 A 3-Pole only, 70–225 A)c
DJM (400 A, 2 or 3-Pole, 160–400 A)f
QO (125 A, 2-Pole, 40–125 A)
QO (225 A, 2-Pole, 40–125 A)e
QB (225 A 2 or 3-Pole, 70–225 A)
LAL 400 A, 2 or 3-Pole, 125–400 A)e
QO-VH (125 A, 2-Pole, 40–125 A)
QO-VH (225 A, 2-Pole, 40–60 A)e
DJM (400 A, 2-Pole, 160–400 A)f
QD (225 A 2-Pole, 70–225 A)
QO-VH (125 A, 2-Pole, 40–125 A)
QO-VH (225 A, 2-Pole, 40–60 A)e
QD (225 A 2-Pole only, 70–225 A)
QD (225 A 3-Pole only, 70–225 A)c
DJM (400 A, 2 or 3-Pole, 160–400 A)f

400–800 A EZM Main Device (1-Phase or 3-Phase) with Class T (300 Vac) Fuses
installed.

1200 A EZM Main Device (1-Phase only) with Class T (300 Vac) Fuses installed.

400–800 A EZM Main Device (1-Phase or 3-Phase) with Class T (300 Vac) Fuses
installed.

a Meter center short circuit current rating is equal to the lowest short circuit current rating given in the table for any circuit breaker installed in any meter
panelboard in the meter center.
b Short circuit current rating is measured at the LINE SIDE terminals of the integral mounted or remote mounted main providing overcurrent protection for
the EZM metering equipment lineup.
c Limited to 208Y/120 Vac maximum (3-pole circuit breaker only).
d Requires use of EZM125QOA adapter (order separately). Refer to page 50 for pricing.
e Supplied with 400 A circuit breaker(s) factory installed, consult local field office for ordering other ampere ratings.
f Supplied with factory installed circuit breaker(s), with an adjustable trip rating range of 160–400 A.

For additional information, reference Catalog #4100CT9801.
© 2004 Schneider Electric
All Rights Reserved
6/7/04

53

METERING EQUIPMENT

Selection Information

Switches &
D I S C O N N E C T S

Safety Switches
In 1909 Thomas Edison chose a Square D safety switch for his laboratories
in Philadelphia. Today, Square D safety switches are still the best choice for
performance and reliability. That’s why professionals choose Square D
safety switches 2:1 over any other brand.

General Duty Switches
Square D general duty safety switches meet the needs of residential and
commercial applications with many features designed for economy, safety,
and superior performance. They are ideal for lighting, air conditioning, and
appliance loads up to 240 Vac. In addition, they may be used as
service entrance equipment.
■ Simplifies installation, operation, and maintenance while saving money.
■ Rugged enclosures built to last.
■ Padlock provisions.
■ Operating mechanism exceeds the number of operations required by

NEMA and UL standards.

54

General Duty Safety Switches
Light Duty
Class 3130

www.SquareD.com
For the most up-to-date information

General Duty—
Up To 100,000 A Short Circuit Current Rating With Proper Current Limiting Fusing
General duty safety switches are designed for residential and commercial applications where economy is a prime
consideration. Typical loads are lighting, air conditioning and appliances. They are suitable for use as service
equipment when equipped with a factory-installed neutral assembly or a field-installed service grounding kit.
General duty safety switches are UL Listed, File E2875, and meet or exceed the NEMA Standard KS1.
400 and 600 A general duty switches (NEMA 1 only) will accept Class J fuses and are UL Listed for use on systems
with up to 100,000 RMS symmetrical amperes available fault current. 600 A requires Class J fuse kit—GDJK600
(page 56).
Class T 400–800 A general duty safety switches, use 300 Vac Class T fuses and are UL Listed for use on systems
with up to 100,000 RMS symmetrical amperes available fault current.
Fusible
System

Amps

Fuse

Catalog
Number

Price

NEMA 3Ra
Rainproof
Catalog
Number

Class R Fuse Kits
Field Installableb

Price

Catalog
Number

Price

Horsepower Ratings
Std.
Max.
(Using Fast Acting- (Using Dual ElementOne Time Fuses)
Time Delay Fuses)
1Ø
3Ø
1Ø
3Ø

2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac
30

Plug

Use Light Duty Device for This Application (see below)

–

–

–

–

30

Cart.

Use 3 Wire Devices
for this application.

–

–

–

–

11⁄2
11⁄2
3
71⁄2
15
–
–

–
3 c
71⁄2 c
15 c
25 c
–
–

3
3
10
15
–
–
–

–
71⁄2 c
15 c
30 c
60 c
–
–

3
10
15
–
–
–
–
–
–

71⁄2
15n
30n
60n
125
–
150
–
–

3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac (Plug), 240 Vac (Cart.) Maximum
30
Plug
D211N
$ 60.00 D211NRB
$ 118.00
–
–
30
Cart.
D221N
81.00 D221NRB
125.00 DRK 30
$17.10
60
Cart.
D222N
137.00 D222NRB
217.00 RFK 03H
17.00
100
Cart.
D223N
284.00 D223NRB
320.00 RFK 10
31.80
200
Cart.
D224Nl
589.00 D224NRBl
800.00 HRK 1020
31.80
400
Cart.
D225N
1703.00 D225NR
2306.00 DRK 40
74.00
600
Cart.
D226N
3406.00 D226NR
4379.00 DRK 600
74.00
4 Wire (3 Blades and Fuseholders, 1 Neutral)—240 Vac Maximum
30
Cart.
D321N
$ 125.00 D321NRB
$ 195.00 DRK 30
$17.10
60
Cart.
D322N
217.00 D322NRB
294.00 RFK 03H
17.00
100
Cart.
D323N
376.00 D323NRB
544.00 RFK 10
31.80
200
Cart.
D324Nl
801.00 D324NRBl
974.00 HRK 1020
31.80
400
Cart.
D325N
2075.00 D325NR
2595.00 DRK 40
74.00
400 Class T D325NT
1996.00 D325NTR
2494.00
–
–
600
Cart.
D326N
3882.00 D326NR
5251.00 DRK 600
74.00
600 Class T D326NT
3732.00 D326NTR
5046.00
–
–
800 Class T T327N
6481.00 T327NR
8292.00
–
–

11⁄2
3
71⁄2
15
–
–
–
–
–

3
71⁄2n
15n
25n
50
50
75
75
100

Not Fusible
NEMA 1 Indoor
NEMA 3R Rainproofa
Horsepower Ratings (Max.)
Catalog Number
Price
Catalog Number
Price
1Ø
3Ø
2 Wire (2 Blades)—240 Vac Maximum
30
–
DU221RBd
$118.00
3
–
60
–
DU222RBd
235.00
10
–
60
QO260NATSef
$ 107.00
QO200TR efg
112.00
10
–
100
QO2000NSeh
184.00
QO2000NRBeh
225.00
20
–
200
Use 3-pole Switch
–
Use 3-pole Switch
–
–
–
400
Use 3-pole Switch
–
Use 3-pole Switch
–
–
–
600
Use 3-pole Switch
–
Use 3-pole Switch
–
–
–
3 Wire (3 Blades)—240 Vac Maximum
30
DU321d
$ 103.00
DU321RBd
$195.00
3
71⁄2
60
DU322d
137.00
DU322RBd
295.00
10
15
100
DU323i
318.00
DU323RBi
544.00
15
30
200
DU324j
589.00
DU324RBj
974.00
15
60m
400
DU325d
1465.00
–
–
–
125
600
DU326k
2794.00
–
–
–
150
a Bolt-on hubs—Refer to page 62.
b When installed, this kit rejects all but Class R fuses. When installed with this kit and Class R fuses, the switch is UL Listed for use on systems with up
to 100,000 RMS symmetrical amperes available fault current.
c For corner grounded delta systems only. Use switching poles for ungrounded conductors.
d Suitable for use as service equipment requires field installation of a service grounding kit (page 56).
e Enclosed molded case switch—Refer to page 29.
f Includes factory installed grounding kit.
g Not service entrance rated—Refer to page 33 for more information.
h Includes factory installed neutral.
i For service equipment use or when neutral is required, order part number SN0610 at $71.00.
j Suitable for use as service equipment, requires field installation of neutral assembly SN20A at $133.00.
k Suitable for use as service equipment requires field installation of neutral assembly D600SN at $153.00.
l For 200% neutral, order (1) additional neutral kit SN20A at $133. and (1) neutral jumper kit SN20NI at $18.40.
m If corner grounded delta, install neutral and use outer switching poles for ungrounded conductors.
n If corner grounded delta, use outer switching poles for ungrounded conductors.
System

Amps

D223N
UL LISTED SHORT CIRCUIT
WITHSTAND RATING
(RMS SYMMETRICAL AMPERES)
Switch
Fuse
Short Circuit
Type
Class
Rating
Fusible
Plug
10,000
H
10,000
K
10,000
J
100,000
R
100,000
T
100,000
Not Fusible
H
10,000
o
K
10,000
J
100,000
R
100,000p
T
100,000
o The UL Listed short-circuit current rating
for Square D general duty, not fusible
switches is based on the switch being
used in conjunction with fuses.
Evaluation of not fused switches in
conjunction with molded case circuit
breakers has not been performed. If a
UL Listed short-circuit current rating is
required, this not fused switch must be
replaced with a Square D general duty
fusible safety switch equipped with the
appropriate class and size fusing. The
UL Listed short-circuit current rating of
the fusible switch is typically as follows;
when used with Class H & K fuses—
10,000 A, Class R and J fuses—
100,000 A. Consult the wiring diagram
of the switch to verify the UL Listed
short-circuit current rating.
p 50,000 amperes for 60 A not fusible
switch.

SAFETY SWITCHES

NEMA 1
Indoor

L211N

Light Duty—Visible Blades 10,000 A Short Circuit Current Rating
The Square D light duty enclosed switch is ideal for home applications in disconnecting power to workshops, hobby rooms, furnaces and garages.
Fusible
Fusible
NEMA 1 Indoor
Catalog Number
Pricek
2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac
System

Amps

Fuse

30

Plug

L111N

$35.90

Horsepower Ratings
Std.
Max.

1⁄2

NEMA 1 Indoor
Catalog Number
Pricek
3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac
System

Amps

Fuse

30

Plug

L211N

Horsepower Ratings
Std.
Max.

$47.80

11⁄2q

3q

65.00

11⁄2 q

3q

2
30

Cart.

L221N

q For single phase hp rating, use two switching poles.
© 2004 Schneider Electric
All Rights Reserved
6/7/04

kDE1A

DE2A

Discount
Schedule

55

General Duty Safety Switches
Accessories, Lug Data and Dimensions
Class 3130

www.SquareD.com
For the most up-to-date information

Field Installable Electrical Interlock Kits

Field Installable Fuse Puller Kits

Electrical interlocks for Series F 100–200 A general duty
safety switches and Series F 60 A fusible general duty
safety switches are available in kit form for field installation.
Each kit contains instructions for proper field mounting. A
pivot arm operates from switch mechanism, breaking the
control circuit before the main switch blades break.
Switches with electrical interlocks installed are UL Listed.
Electrical Interlock Kit

Kit consists of three fuse pullers as required for a 3-pole, fusible, 60 and 100 ampere
general duty switch. Kits can be installed in 60 and 100 ampere Series F switches.

Switch
Ampere Rating

Electrical Interlock Kit
Catalog Numbera

Fusible Series F 60

EIK031 or EIK032

Series F 100–200

EIK1 or EIK2

Description
Series F 60 Ampere Fuse Puller Kit
Series F 100 Ampere Fuse Puller Kit

Catalog Number
FPK03
FPK0610

Price
$20.00
28.40

Field Installable Service Grounding Kits
Switch Ampere
Rating

Catalog
Number

Price

30

PK3GTA1

$ 7.60u

Series E 60

PK3GTA1

7.60u

Series F 60

GTK03

7.60

100
200
400
600
800

GTK0610
PKOGTA2
PKOGTA2
(Two Required)
PKOGTA3

12.60
36.80

Wire Size
AWG
(2) #12 Cu or
(2) #10 Al or
(1) #4 Al/Cu Max.
(2) #12 Cu or
(2) #10 Al or
(1) #4 Al/Cu Max.
(2) #12 Cu or
(2) #10 Al or
(1) #4 Al/Cu Max.
(2) #1/0 Al/Cu Max.
(2) #2/0 Al/Cu Max.
(2) #2/0 Al/Cu Max.
Per Lug
(6) #3/0 Al/Cu Max.

Price
$145.
207.

a Electrical interlock kit catalog numbers with -1 suffix indicates one normally
open and one normally closed contact; -2 indicates two normally open and
two normally closed contacts. Kits are UL Listed.

Field Installable Class J Fuse Kit
Kit consists of three Class J fuse adapters as required for
3-Pole, fusible 600 A General Duty switch. Kit can be
installed in 600 A series E3 switches only (NEMA 1).
Switch
Ampere Rating

Class J Kit
Catalog Number

Price

600 A Series E3

GDJK600

$195.

36.80
82.00

Terminal Lug Data b
Ampere
Rating

W

Wire Range
Conductors Wire Bending Space
Per NEC Table 373-6
Per Phase
AWG/kcmil

30
60
100
200
400
NEMA 1

1
1
1
1
1
or
2

#12–6 (Al) or #14–6 (Cu)
#10–3 (Al) or #14–3 (Cu)
#12–1 (Al) or #14–1 (Cu)
#6 –250 (Al/Cu)
#1/0 –600 (Al/Cu)
or
#1/0 –300 (Al/Cu)

400
NEMA 3R

2

#1/0–250 (Al/Cu)

600
800

2
3

#4 –500 (Al/Cu)
#3/0 –500 (Al/Cu)

H

Lug Wire Range
AWG/kcmil
#12–6 (Al) or #14–6 (Cu)
#10–2 (Al) or #14–2 (Cu)
#12–1/0 (Al) or #14–1/0 (Cu)
#6 –300 (Al/Cu)
(1) #1/0 –750 (Al/Cu)
or
(2) #1/0 –300 (Al/Cu)
(1) #1 –600 (Al/Cu)
or
(2) #1/0 –250 (Al/Cu)
#4 –600 (Al/Cu)
#3/0 –500 (Al/Cu)

b 30–100 A switches suitable for 60°C or 75°C conductors. 200–800 A switches suitable for 75°C conductors.
W/H

D

Field Installable Lug Kit
Kit consists of three line, three load and two neutral lugs as required for a 3-pole 400 A or
600 A general duty switch. Kit can be installed on 400 or 600 A Series E3 switches. This
kit applicable to NEMA 1 enclosures only.
Switch Ampere Rating

Lug Kit Catalog Number

Wire Range/NEC
AWG/kcmil

Lug Wire Range
AWG/kcmil

Price

GD4060LK

(1) 1/0–600
(2) 1/0–500
(4) 1/0–250

(2) 1/0–600
(4) 1/0–250

$269.

400 or 600 A Series E3

SAFETY SWITCHES

Approximate Dimensions
Catalog
Number
L111N
L211N
L221N
D211Nc
D211NRBc
D221Nc
D221NRBc
D222N
D222NRB
D223N
D223NRB
D224N
D224NRB
D225N
D225NR
D226Nc
D226NRc
D321Nc
D321NRBc
D322N
D322NRB
D323N
D323NRB
D324N
D324NRB
D325Nc
D325NTc
D325NRc

Series
E2
E2
E2
E3
E2
E3
E3
F1
F1
F3
F3
F1
F1
E3
E1
E3
E1
E3
E3
F1
F1
F3
F3
F1
F1
E3
E3
E1

H
IN
7.63
7.63
7.63
9.25
9.63
9.25
9.63
14.63
14.88
17.50
17.50
29.00
29.25
45.12
30.63
49.13
49.13
9.25
9.63
14.63
14.88
17.50
17.50
29.00
29.25
45.12
45.12
30.63

mm
194
194
194
235
245
235
245
372
378
445
445
737
743
1146
778
1248
1248
235
245
372
378
445
445
737
743
1146
1146
778

W
IN
5.00
5.00
5.00
6.75
7.25
6.75
7.25
6.50
6.63
8.50
8.50
17.25
17.25
24.00
21.38
24.00
24.75
6.75
7.25
6.50
6.63
8.50
8.50
17.25
17.25
24.00
24.00
21.38

mm
127
127
127
171
184
171
184
165
168
216
216
438
438
610
543
610
629
171
184
165
168
216
216
438
438
610
610
543

W/H
D
IN
mm
IN
6.13 156 4.00
6.13 156 4.00
6.13 156 4.00
7.25 184
3.63
7.75 197
3.75
7.25 184
3.63
7.75 197
3.75
7.45 189
4.88
7.45 189
4.88
10.50 267
6.50
10.50 267
6.50
19.00 483
8.25
19.00 483
8.25
24.88 632
8.88
22.25 565 10.13
24.88 632
8.88
25.13 638
8.88
7.25 184
3.63
7.75 197
3.75
7.45 189
4.88
7.45 189
4.88
10.50 267
6.50
10.50 267
6.50
19.00 483
8.25
19.00 483
8.25
24.88 632
8.88
24.88 632
8.88
22.25 565 10.13

Std.
mm Pack
102
1
102
1
102
1
92
5
95
5
92
5
95
5
124
1
124
1
165
1
165
1
210
1
210
1
226
1
257
1
226
1
226
1
92
5
95
5
124
1
124
1
165
1
165
1
210
1
210
1
226
1
226
1
257
1

Catalog
Number

Series

H

W
mm
IN
778 21.38
1248 24.00
1248 24.00

W/H
D
mm
IN
mm
IN
543 22.25 565 10.13
610 24.88 632 8.88
610 24.88 632 8.88

mm
257
226
226

1
1
1

1248 24.75
1246 24.75
245 7.25
245 7.25

629 25.13
629 25.13
184 7.75
184 7.75

638
638
197
197

8.88
8.88
3.75
3.75

226
226
95
95

1
1
5
5

Std.
Pack

D325NTRc
D326Nc
D326NTc

E1
E3
E3

IN
30.63
49.13
49.13

D326NRc
D326NTRc
DU221RBc
DU222RBc

E1
E1
E2
E1

49.13
49.13
9.63
9.63

DU321c
DU321RBc

E2
E2

9.25
9.63

235
245

6.75
7.25

171
184

7.25
7.75

184
197

3.63
3.75

92 5
95 5

DU322c
DU322RBc

E1
E1

9.25
9.63

235
245

6.75
7.25

171
184

7.25
7.75

184
197

3.63
3.75

92 5
95 5

DU323
DU323RB
DU324
DU324RB

F3
F3
F1
F1

17.50
17.50
29.00
29.25

445 8.50
445 8.50
737 17.25
743 17.25

216
216
438
438

10.50
10.50
19.00
19.00

267
267
483
483

6.50
6.50
8.25
8.25

165
165
210
210

DU325c
DU326c

E3
E3

45.12
49.13

1146 24.00
1248 24.00

610 24.88
610 24.88

632
632

8.88
8.88

226 1
226 1

QO200TRc
QO260NATSc
QO2000NRBc
QO2000NSc

G3
E2
E1
E1

6.50
9.25
14.00
13.38

118
124
197
156

...
...
...
...

3.88
3.25
4.50
3.50

99
83
114
89

T327Nc
T327NRc

E1
E1

49.13
49.13

632
638

8.88
8.88

226 1
226 1

165
235
356
340

4.63
4.88
7.75
6.13

1248 24.00
1248 24.75

...
...
...
...

610 24.88
629 25.13

1
1
1
1

5
1
1
1

c Does not have a cover draw as indicated in above drawing.

56

uDE3A

DE1

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Double Throw Safety Switches
Fusible and Not Fusible
Class 3140

www.SquareD.com
For the most up-to-date information

New—Series F
30–100 A Types DT, DTU (Series F)
• Fusible (DT) and not fusible (DTU) switches
available.
• Manually operated switch suitable for use in
accordance with article 702 of the NEC,
ANSI/NFPA 70.
• Standards: UL 98, NEMA KS1, CSA, and NOM
• Modular design—switch handle, lock-plate, switch
mechanism, line and load bases are field
replaceable.
• UL listed short circuit current ratings up to 200,000 A
(using Class R, J, or T fuses—see table for rating).
• Load make/break rated.
• Meets NEMA hp ratings.
• Dual cover interlock.
• May be padlocked ON or OFF.
• Lock-off accepts up to three padlocks.
• Side-opening door.
• Quick make/quick break mechanism.
• Meets NEMA requirements as heavy duty switch.
(Note: handle is all black)
• Electrical interlock kits field installable.
• Neutral assembly kits field installable (2 and 3-pole
switches).
• UL Listed as suitable for use as service equipment.
• Supplied as standard for switching one load between
two power sources, and may be field converted to
switch one power source between two loads.

30–100 A DT, DTU (Series F5)
NEMA 1

DTU (Series E) 200 A
NEMA 3R
82,000 and 92,000 Line
NEMA 1

92251

© 2004 Schneider Electric
All Rights Reserved
6/7/04

• Not fusible
• Designed for manual transfer of loads from one
supply to another.
• UL Listed switches are suitable for use in accordance
with Article 702 of the National Electrical Code,
ANSI/NFPA 70.
• All 82,000–92,000 and DTU double throw switches
are continuous duty rated for their nameplate
ampere rating.
• The 82,000 and DTU (Series E) switches are load
make/break rated.
• The 92,000 switches are not load make/break rated
and should be used for isolating purposes only.
• UL Listed as suitable for use as service equipment
except as footnoted.
• Horsepower rated only as footnoted.
• All accessories, except service ground kits, require
factory installation.
• For application above 600 amperes, see
Supplemental Digest.

For additional information, reference Catalog #3100CT9801.

57

SAFETY SWITCHES

30 (Series T4), 200–600 A Types 82,000,
92,000 and 200 A DTU (Series E)

Double Throw Safety Switches
240 Volt
Class 3140

www.SquareD.com
For the most up-to-date information

NEMA 4,4X,5
Stainless

NEMA 3R

NEMA 12
Gasketed

240 Vac
Std.

Catalog No.

Price

Catalog No.

Max.

250 Vdc
c

Current
Series

System

Ampere
Rating

Horsepower Ratings ai
NEMA 1

Price

Catalog No.

Price

Catalog No.

Price

1Ø

3Ø

1Ø

3Ø

15 b

15

30 b

20

Fusible
2-Pole, 240 Vac—250 Vdc
Line

100

F

DT223

$1586.

DT223RB

$2037.

...

...

...

...

7.5

F
F
F

DT321
DT322
DT323

1097.
1313.
2069.

DT321RB
DT322RB
DT323RB

1477.
1741.
2483.

...
...
...

...
...
...

...
...
...

...
...
...

1.5d
3d
7.5d

3b
7.5 b
15 b

3d
10d
15d

7.5 b
15 b
30 b

5
10
20

60
100

F
F

DTU222
DTU223

...
$ 898.

...
...

...
...

...
...

...
...

...
...

...
...

10
15

...
...

10e
20e

30
200
200
400

T4
E
E
E

92251f
82254
82254NW
92255 f

390.
1210.
1914.
3548.

...
DTU224NRB fj
...
92255R f

...
1451.
...
5251.

...
...
...
...

...
...
...
...

...
H82254
...
H92255 f

...
$3114.
...
6259.

...
15
15
...

...
...
...
...

...
...
...
...

...
...
...
...

...
...
...
...

30
60
100

F
F
F

DTU321
DTU322
DTU323

536.
746.
1176.

...
...
DTU323RB

...
...
1302.

...
...
...

...
...
...

...
...
...

...
...
...

...
...
...

3b
...
...

5d
10d
15d

10b
15b
30b

5e
10e
20e

30
200
200
400
600

T4
E
E
E
E

92351f
82354f
DTU324Nfj
92355f
92356 c

458.
1709.
1865.
4874.
6605.

...
DTU324NRBfj
...
92355Rf
92356R f

...
2003.
...
8692.
9081.

...
...
...
...
...

...
...
...
...
...

...
H82354f
...
H92355f
H92356

...
3605.
...
7100.
9508.

...
...
...
...
...

...
15
15
...
...

...
...
...
...
...

...
...
...
...
...

...
...
...
...
...

30
200
400
600

T4
E
E
E

92451f
92454 g
92455
92456

635.
2811.
6389.
7683.

...
92454RB g
92455R
92456R

...
5011.
9012.
9904.

...
...
...
...

...
...
...
...

...
H82454 g
H92455
H92456 h

...
4519.
8860.
10641.

...
...
...
...

...
15 g
...
...

...
...
...
...

...
...
...
...

...
...
...
...

Line

Load

3-Pole, 240 Vac—250 Vdc
Line

Line

30
60
100

Load

Not Fusible
2-Pole, 240 Vac—250 Vdc
Line

Line

$ 641.
914.

...
DTU223RB

Load

3-Pole, 240 Vac—250 Vdc
Line

SAFETY SWITCHES

Line
Load

4-Pole, 240 Vac

a
b
c
d
e
f
g
h
i
j

Refer to page 6-35 for additional motor application data. The starting current of motors or more than standard horsepower may require the use of fuses with appropriate time delay characteristics.b
If used on corner grounded delta systems, install neutral and use outer switching pole for ungrounded conductors.b
For switching dc, use two switching poles..
Use outer switching poles.
Maximum rating.
240 Vac onlyb
240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 58
Hp rating applies only to H82454. (92454, 92454RB are not Hp rated)b
Not UL listed or suitable for use as service equipment.b
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 59
Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses.
Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60
Neutral included with device.
Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . . page 61
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 62

For additional information, reference Catalog #3100CT9801.

58

DE1

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Double Throw Safety Switches
Application Data
Class 3140

www.SquareD.com
For the most up-to-date information

Situations Requiring
Fuses:

UL Listed Short Circuit Current Ratings

30–100 A Type DT
(Series F):
Select DT switches from
page 58 which have
provisions for accepting
fuses.
30, 200–600 A Type
82,000, 92,000
(Series E, T4),
all DTU devices:
Use the not fused double
throw switches from
page 58 in conjunction
with standard fused
devices, and install them
according to the below
diagram 1 or 2.
Line

Ampere
Rating

Voltage
Rating

Type DT
(Series F)

30–100 A

240 V

Type DTUb
(Series F)

30–100 A

240 V

DTU224NRB and
DTU324NRB
(Series E)

200 A

240 V

DTU324N
(Series E)

200 A

240 V

Switch Type

Type 82,000

all

Type 92,000

all

UL Listed
Fuse Class
H, K

10,000

R, J

200,000

H or K
R or J
H, K
H, K
R, J
H, K

240 V

Short Circuit
Current Ratinga
(RMS
Symmetrical
Amperes)

R, J

10,000c
200,000
10,000c
10,000c
100,000
10,000c
100,000

600 V

H, K

10,000c

240 V

H, K

10,000c

a Rating applies to AC only. The UL Listed short circuit current rating for Not Fusible switches is based on the switch being used in conjunction with the
corresponding fuse type. Evaluation of Not Fusible switches in conjunction with molded case circuit breakers has not been performed.
b The DTU361 and DTU361RB are also suitable for use on a circuit capable of delivering not more than
(A) 18,000 rms summetrical A, 600 Vac maximum when protected by Type FH circuit breaker rated 30 A maximum or
(B) 14,000 rms symmetrical A, 600 Vac maximum when protected by Type FA circuit breaker rated 30 A maximum.
c Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used ahead of an unfused safety switch when there is up to
10,000 A short circuit current available.

Terminal Lug Data for Type DT, DTU (Series F) Double Throw Safety Switches
Not-Fusible
D/T Switch

NEMA 1, 3R, 4, 4X, 12

Line

Fusible
Single
Throw
Switch or
Circuit
Breaker

Wire Range
Wire Bending
Space Per
NEC Table 373-6
AWG/kcmil
Al/Cu

Standard Lug
Wire Range
AWG/kcmil
Al/Cu

Optional
Compression Lug
Field Installable

Switch
Ampere
Rating

Wires
per
Phase

30–60 A
Type DT, DTU
(Series F)

1

#12–2 (Al)
or
#14–2 (Cu)

#12–2 (Al)
or
#14–2 (Cu)

C10-14,
D8-14,
or E6-14d

1

#12–1/0 (Al)
or
#14–1/0 (Cu)

#12–1/0 (Al)
or
#14–1/0 (Cu)

VCEL02114S1e

100 A
Type DT, DTU
(Series F)

See Digest 173 pages 3-11 and 3-13 for appropriate kit.
Order 2 kits per switch.

Terminal Lug Data for Types 82,000, 92,000 and for E-Series DTU devices f

Diagram 1

Ampere
Rating

Wires
per
Phase

Wire Range
Wire Bending Space
Per NEC Table 373-6
AWG/kcmil
Al/Cu

Lug Wire Range
AWG/kcmil
Al/Cu

Optional
Compression Lugs
Field Installable

30 A (Series T4)g

1

#14–8

#12–2 (Al)
or
#14–2 (Cu)

...

200

1

#6–300

#6–300

VCEL030516H1e

400

2

#4–250

#4–350

...

600

2

#4–500

#4–600

...

Line
Fusible
Single
Throw
Switch or
Circuit
Breaker

Not-Fusible
D/T Switch

d
e
f
g

Thomas and Betts catalog numbers.
VERSA-CRIMP® catalog numbers.
200–600 A switches suitable for 75° C conductors.
30 A switches suitable for 60° C or 75° C conductors.

SAFETY SWITCHES

Load

Load

Optional Copper Only Lug

Fusible
Single
Throw
Switch or
Circuit
Breaker
Line
Diagram 2

240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 58
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 59
Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 60
Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . .page 61
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 62

For additional information, reference Catalog #3100CT9801.

© 2004 Schneider Electric
All Rights Reserved
6/7/04

DE1

Discount
Schedule

59

Double Throw Safety Switches
Dimensions—Series F Devices
Class 3140

www.SquareD.com
For the most up-to-date information

30–100 A Type DT, DTU (Series F)—Approximate Dimensions

W

Catalog
Number

H

Series

H

W

W/H

D

IN

mm

IN

mm

IN

mm

IN

mm

DT223
DT223RB
DT321
DT321RB
DT322

F5
F5
F5
F5
F5

38.00
38.00
38.00
38.00
38.00

965
965
965
965
965

9.88
6.87
10.25
10.25
10.25

251
174
260
260
260

11.13
8.12
11.50
11.80
11.50

283
206
292
300
292

6.75
6.60
6.75
6.60
6.75

171
168
171
168
171

DT322RB
DT323
DT323RB
DTU222
DTU223

F5
F5
F5
F5
F5

38.00
38.00
38.00
29.94
29.94

965
965
965
760
760

10.25
9.88
6.87
10.25
10.25

260
251
174
260
260

11.80
11.13
8.12
11.96
11.96

300
283
206
304
304

6.60
6.75
6.60
6.93
6.93

168
171
168
176
176

DTU223RB
DTU321
DTU322
DTU323
DTU323RB

F5
F5
F5
F5
F5

30.50
29.94
29.94
29.94
30.50

775
760
760
760
775

10.25
10.25
10.25
10.25
10.25

260
260
260
260
260

11.96
11.96
11.96
11.96
11.96

304
304
304
304
304

6.93
6.93
6.93
6.93
6.93

176
176
176
176
176

D

W/H

NEMA 1

W

H

W/H

D

SAFETY SWITCHES

NEMA 3R

240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 58
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 59
Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60
Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . . page 61
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 62

For additional information, reference Catalog #3100CT9801.

60

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Double Throw Safety Switches
Dimensions—Series E, T4 Devices
Class 3140

www.SquareD.com
For the most up-to-date information
W/H
W

D

30, 200–600 A Types 82,000, 92,000 and E-Series DTU devices,
NEMA 1 and 3R—Approximate Dimensions
Catalog
Number

H

NEMA 1

W/H
W

Series

H

W

W/H

D

IN

mm

IN

mm

IN

mm

IN

mm

DTU224NRB
DTU324N
DTU324NRB
82254
82254NW

E1
E1
E1
E1
E1

32.50
32.50
32.50
30.88
30.88

826
826
826
784
784

20.63
23.50
24.13
15.75
20.00

524
597
613
400
508

24.00
26.85
26.25
19.63
23.88

610
682
667
499
607

10.63
10.63
10.63
9.75
11.75

270
270
270
248
298

82354
92251
92255
92255R
92351

E1
T4
E1
E1
T4

30.88
10.00
31.50
31.25
10.00

784
254
800
794
254

20.00
8.00
21.00
30.13
8.00

508
203
533
765
203

23.88
9.75
24.25
33.00
9.75

607
248
616
838
248

11.75
4.75
14.13
11.38
4.75

298
121
359
289
121

92355
92355R
92356
92356R
92451

E1
E1
E1
E1
T4

31.50
31.25
53.00
52.63
10.00

800
794
1346
1337
254

29.38
30.13
34.25
34.38
10.00

746
765
870
873
254

32.63
33.00
37.50
37.63
11.75

829
838
953
956
298

14.13
11.38
16.38
13.88
4.75

359
289
416
353
121

92454
92454RB
92455
92455R
92456

E1
E1
E1
E1
E1

31.13
30.78
31.50
31.20
53.00

791
782
800
792
1346

24.75
20.50
37.75
35.65
44.25

629
521
959
906
1124

28.25
28.00
41.13
38.52
47.50

718
711
1045
978
1207

11.75
10.62
14.13
10.90
16.38

298
270
359
277
416

92456R

E1

52.50

1334

43.70

1110

48.00

1219

13.50

343

D

H

SAFETY SWITCHES

DTU—200 A
NEMA 3R

240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 58
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 59
Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 60
Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . .page 61
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 62

For additional information, reference Catalog #3100CT9801.

© 2004 Schneider Electric
All Rights Reserved
6/7/04

61

Double Throw Safety Switches
Accessories
Class 3140

www.SquareD.com
For the most up-to-date information

Neutral Assembly For 2 and 3-Pole Switches Only
Switch
Ampere
Rating
30–100 A
Type DT, DTU
(Series F)

Field Installed
Standard
Neutral Kit
Catalog No.

Terminal
Data
AWG/kcmil

SN0310

Price

#14–1/0
Al/Cu

$ 76.

Service Grounding Kit (Required for service equipment use.)
Field Installed
Copper only
Neutral Kit
Catalog No.

Price

Switch
Ampere
Rating

#14–1/0
Cu

$ 80.

Terminal
Data
AWG/kcmil

SN0310C

30 A
(Series T4)

a

a

605.

...

...

...

200 A
Type 82000, 92,000
and DTU (Series E)

a

a

740.

a

a

740.

400–600 A
Type 82000, 92,000

a

a

948.

a

a

948.

a For Type 82,000 and 92,000 switches, neutral is available factory installed on 2 and 3-pole double throw switches.
Not UL Listed. To order, add suffix N to the standard catalog number and add the above price to the list price of the
switch. For DTU (Series E) switches, neutral is factory installed in standard device and is UL Listed.

Field Installed
Service Ground Lug Kit
Catalog Number

Terminal
Data
AWG/kcmil

Price

30–100 A
Type DT, DTU
(Series F)

Included

Included

std.

30 A
Type 92,000

DT30SG

(4) #14–4 Cu/Al

200 A
Type 82000, 92,000
and DTU (Series E)

DT100SG

(3) #14–1/0 Cu/Al

20.00

400–600 A
Type 82000, 92,000

PKOGTA2
(2 required)

(4) #10–2/0 Cu or
(4) #6–2/0 Al

35.00

$19.60

Class R Fuse Kits
When installed, this kit rejects all but Class R fuses. Kits
are available for field installation. For factory installation,
add “CLR” suffix to catalog number.

Electrical Interlocks
Switch
Ampere
Rating

Field Installed
Electrical Interlock
Kit Catalog Numberb

Price

Factory Installed
Price Adder
Per Switch

EIK1, EIK2c

$207.

$603.d

200 A
Type 82000, 92,000
and DTU (series E)

...

...

742.e

400–600 A
Type 82000, 92,000

...

...

932. e

30–100 A
Type DT, DTU
(series F)

Switch
Ampere
Rating

Class R
Fuse Kit
Catalog
Number

Series
Number

Factory
Installed
Price

Price

Class R Fuse Kits—240 V (two kits per 3-pole switch)
30
60
100

F5
F5
F5

RFK03
RFK06
RFK10

$16.30
17.00
31.80

$260.00
260.00
260.00

Class R Fuse Kits—600 V (two kits per 3-pole switch)
30
60
100

b Electrical interlock kit catalog numbers with “1” suffix indicate one normally open and normally closed contact; “2”
indicates two normally open and two normally closed contacts. See Digest 173 page 3-9 for electrical interlock
ratings.
c 30–100 A Type DT, DTU (Series F) switches contain (2) separate switching mechanisms. Each mechanism will
accept an electrical interlock. Some applications may therefore require (2) electrical interlocks.
d 30–100A Type DT, DTU (Series F) switches with factory installed electrical interlocks installed are UL Listed and
interlocks are furnished with 2 N.O. /2 N.C. contacts installed in both “ON” positions. To order, add suffix EI to
standard catalog number.
e Type 82,000 and 92,000, and DTU (Series E) switches are available with electrical interlock factory installed only.
Not UL Listed. Electrical interlocks are furnished with 2 N.O. /2 N.C. contacts and are installed in both “ON” positions.
To order, add suffix EI to standard catalog number.

F5
F5
F5

RFK06
RFK06H
RFK10

17.00
17.00
31.80

260.00
260.00
260.00

Lock-On Provisions—UL Listed
30–100 A type DT, DTU (Series F) and type 92,000
included on standard device.
Type 82,000 and 200 A DTU (Series E): available factory
installed. Add SPLO to catalog number and add $273. to
list price.

Rainproof Bolt-On Hubs—For Use On NEMA 3R Enclosures

SAFETY SWITCHES

“RB Hub”

Conduit
Size
Hub Cat. No.
Price Each
r

B075

B100

B125

B150

B200

B250

B300

B350

B400

Closing
Cap
BCAP

$23.30

$23.30

$23.30

$23.30

$42.90

$71.00

$130.00

$200.00

$245.00

$2.50

3⁄4

11⁄4

1

11⁄2

21⁄2

2

31⁄2

3

4

NEMA 3R rainproof enclosures with catalog number ending in RB have a bolt-on closing cap factory installed. Order bolt-on hubs separately from
table above. For more details see page 20. Hubs thru size 21⁄2 can be directly installed on RB devices. Devices requiring 3" or larger hubs must have
holes cut in the field. Gaskets are provided on 3" and larger hubs.
All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread.

Watertight Hubs—For Use On NEMA 4, 4X and 5 Stainless Steel and NEMA 12 Enclosures
1⁄2
Conduit Trade Size
Standard-Zinc
H050
Hub Catalog Number
Zinc Price Each
$20.70
Chrome Plated
H050CP
Hub Catalog Number
Chrome Plated Price Each
27.10

3⁄4

1

11⁄4

11⁄2

2

21⁄2

3

31⁄2

4

H075

H100

H125

H150

H200

H250

H300

H350

H400

$30.00

$31.40

$36.00

$55.00

$80.00

$ 92.00

$118.00

$188.00

$254.00

H075CP

H100CP

H125CP

H150CP

H200CP

H250CP

H300CP

H350CP

H400CP

37.60

42.90

44.60

64.00

91.00

123.00

162.00

237.00

272.00

240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 58
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 59
Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60
Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . . page 61
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 62

For additional information, reference Catalog #3100CT9801.

62

DE1

rDE1A

Discount
Schedule

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Warranties
Square D Residential Products
A. Limited Warranties —
1. Square D Single Phase Load Centers and Combination Service Entrance Devices. Square D warrants its single phase load
centers and combination service entrance devices to be free from defects in material and workmanship, under normal care and
proper usage in a residential installation, for a period of ten (10) years from the date of installation. If the product fails within the
warranty period because of a defect in material or workmanship, Square D will, at its option, repair or replace the defective part
or parts upon following the notice procedures below and return of product to place of purchase.
2. Square D Load Center Branch Circuit Breakers. Square D warrants its branch circuit breakers to be free from defects in material
and workmanship under normal care and proper usage in a residential installation, for the lifetime of the load center in which it is
installed. If the circuit breaker fails within the warranty period because of a defect in material or workmanship, Square D will
replace the defective breaker free of charge upon following the notice procedures below and return of the product to place of
purchase.
B. Exclusive Remedy — The repair and/or replacement of defective products is your sole and exclusive remedy.
C. Warranty Redemption and Exclusions —
1. Square D must be given prompt written notice of any defect or failure of any product covered by these limited warranties at the
following address: Square D Company, 1415 S. Roselle Road, Palatine, Illinois, 60067, (888) 778-2733, weekdays between the
hours of 8:00 a.m. and 5:00 p.m. Eastern Time.
For warranty redemption, you must return the product to Square D at the above address.
2. Any product returned under these limited warranties, if shipped, must be sent freight costs prepaid. Square D will deliver repaired
or replaced products to buyer, freight costs prepaid. Repaired or replaced products shall be warranted hereunder only for the
unexpired portion of the original warranty period. This warranty does not include costs or reimbursement for labor.
Any limited warranties granted or liabilities assumed hereunder will not apply to products that have been damaged, altered,
repaired or operated otherwise than in conformity with the requirements for safe operation and maintenance.
For your safety and to provide optimum short circuit protection, Square D recommends that you use only the Square D circuit
breakers identified on the load center or combination service entrance device label or wiring diagram. Square D disclaims all
liability for damage, injury or non-performance caused by the use or failure of incompatible or UL Classified circuit breakers.
D. Disclaimer of All Other Warranties — EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE OR ANY WARRANTIES
IMPLIED BY LAW, Square D MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES. TO THE FULLEST EXTENT
PERMITTED BY LAW, Square D DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF
MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING DISCLAIMER MAY NOT APPLY
TO YOU DEPENDING UPON THE PRODUCT YOU PURCHASE, THE APPLICATION AND USE OF YOUR PRODUCT, OR YOUR
STATUS AS A CONSUMER. TO THE EXTENT YOU ARE ENTITLED TO RECOVER UNDER AN IMPLIED WARRANTY, THE
DURATION OF THAT IMPLIED WARRANTY SHALL BE THE PERIOD OF THE EXPRESS LIMITED WARRANTY SET FORTH
ABOVE.
E. Limitation of Liability — Square D expressly disclaims any and all liability to you for any consequential or incidental damages,
damages for loss of use, loss of profits, income or revenue, loss of time or inconvenience, loss or damage to associated equipment,
damages to tangible or intangible property, other than the equipment covered by this limited warranty, cost of substituted or
replacement equipment other than as expressly warranted, damages associated with excessive overvoltages, obsolescence,
abuse, misuse, non-authorized modification, alteration or catastrophic events, or any other incidental, consequential or special
damage arising out of the use of the products. Square D shall not be liable for indirect, special, incidental or consequential damages
with respect to the sale of the products, including any lost revenue or profits, consequential and/or incidental damages, business
interruption or damage to business reputation, regardless of the theory upon which any claim may be based, including any statutory,
tort contract or insurance subrogation causes of action or claims. In no event will Square D’s entire liability to you, including any
liability in the event the exclusive remedy set forth in this agreement fails of its essential purpose, exceed the purchase price for the
affected products. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the preceding
limitations or exclusions may not apply to you. This limited warranty gives you specific legal rights, and you may also have other
rights which vary from State to State.

© 2004 Schneider Electric
All Rights Reserved
6/7/04

63

Warranties
Square D Structured Wiring
A. Limited Warranty — Square D warrants to customers purchasing through authorized Square D distributors that the Square D®
labeled passive (enclosure, cover and any non-powered module) structured wiring products (“passive components”) at the time of
sale by Square D are free from defects in materials and workmanship. Square D also warrants that the Square D labeled active (any
powered module) structured wiring products (“active components”) at the time of sale by Square D are free from defects in materials
and workmanship.
B. Exclusions and Exclusive Remedy —
If within the applicable warranty period, purchaser discovers that a product subject to this Limited Warranty was not as warranted
and promptly notifies Square D in writing, Square D shall repair or replace the product or refund the purchase price, at Square D’s
option. This warranty shall not apply (a) to equipment not supplied by Square D, (b) to equipment or product which shall have been
improperly repaired or altered or modified in a non-authorized manner, (c) to equipment or products which shall have been subjected
to negligence, misuse, accident, or damage by circumstances beyond Square D’s control, or to improper operation, maintenance
or storage, or to other than normal use or service. The foregoing limited warranties do not cover reimbursement for labor,
transportation, removal, installation, or other expenses that may be incurred in connection with repair or replacement. This Limited
Warranty is your sole and exclusive remedy.
C. Warranty Period — For active components, this Limited Warranty shall be in effect until five (5) years following the date of purchase,
or until four (4) years following the house closing by the original owner. For passive components, this Limited Warranty shall be in
effect until fifteen (15) years following the date of purchase, or until fourteen (14) years following the house closing by the original
owner.
D. Warranty Transferable — The unexpired portion of this warranty can be transferred to the subsequent homeowner.
E. Claims Procedure — Send either (1) the original dated sales receipts of the product or
(2) the dated documentation of the original owner’s house closing or (3) original Certificate
of Occupancy along with the damaged product
to Square D Company, 8001 Highway 64 East, Knightdale, NC 27545, Attn: Multi-Link Device Warranty.
Note: If these documents are unavailable, the product may be returned to the address above, and the earliest identifiable date code
stamped on the product will be used to determine if the product is subject to the conditions and terms of this express warranty.
F. Disclaimer of All Other Warranties — EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE OR ANY WARRANTIES
IMPLIED BY LAW, Square D MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES. TO THE FULLEST EXTENT
PERMITTED BY LAW, Square D DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF
MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING DISCLAIMER MAY NOT APPLY
TO YOU DEPENDING UPON THE PRODUCT YOU PURCHASE, THE APPLICATION AND USE OF YOUR PRODUCT, OR YOUR
STATUS AS A CONSUMER. TO THE EXTENT YOU ARE ENTITLED TO RECOVER UNDER AN IMPLIED WARRANTY, THE
DURATION OF THAT IMPLIED WARRANTY SHALL BE THE PERIOD OF THE EXPRESS LIMITED WARRANTY SET FORTH
ABOVE.
G. Limitation of Liability — Square D expressly disclaims any and all liability to you for any consequential or incidental damages,
damages for loss of use, loss of profits, income or revenue, loss of time or inconvenience, loss or damage to associated equipment,
damages to tangible or intangible property, other than the equipment covered by this limited warranty, cost of substituted or
replacement equipment other than as expressly warranted, damages associated with excessive overvoltages, obsolescence,
abuse, misuse, non-authorized modification, alteration or catastrophic events, or any other incidental, consequential or special
damage arising out of the use of the products. Square D shall not be liable for indirect, special, incidental or consequential damages
with respect to the sale of the products, including any lost revenue or profits, consequential and/or incidental damages, business
interruption or damage to business reputation, regardless of the theory upon which any claim may be based, including any statutory,
tort contract or insurance subrogation causes of action or claims. In no event will Square D’s entire liability to you, including any
liability in the event the exclusive remedy set forth in this agreement fails of its essential purpose, exceed the purchase price for the
affected products. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the preceding
limitations or exclusions may not apply to you. This limited warranty gives you specific legal rights, and you may also have other
rights, which vary from State to State.

64

© 2004 Schneider Electric
All Rights Reserved
6/7/04

Square D Conditions Of Sale
NOTE: The following Conditions of Sale are subject to change. All transactions for all products sold by Square D
Company, including Square D brand products and all Schneider Electric brand products, such as Merlin Gerin,
Modicon and Telemecanique brand products, are subject to the latest published Conditions of Sale of the
Square D Company and to any Special Conditions of Sale which may be contained in applicable Square D
quotations and acknowledgments.
1. GOVERNING PROVISIONS AND ACCEPTANCE: All
quotations are subject to these conditions of sale.
Acceptance of an order by Square D shall be expressly
conditioned on Purchaser’s assent to these conditions.
Purchaser’s direction to proceed with engineering,
manufacture or shipment by Square D shall be deemed
evidence of this assent. No modified or other conditions will
be applicable unless those conditions are so stated in
Square D’s proposal or are specifically agreed to in writing
and signed by an authorized official of Square D. Failure to
object to provisions contained in any Purchase Order or
other communication from the Purchaser (including, without
limitation, penalty clauses of any kind) shall not be
construed as a waiver of these Conditions nor an
acceptance of any other provisions. These terms are a
complete statement of the parties’ agreement and may only
be modified in writing signed by both parties. These terms
may not be modified by course of dealing, course of
performance or usage of trade. These terms supersede all
previous written or oral quotations, statements or
agreements. Any contract for sale by and between the
parties shall be governed by and construed according to
the laws of the State of Illinois without regard to its rules on
the conflict of laws. The Convention on the International
Sale of Goods is expressly excluded.
2. QUOTATIONS: Written quotations shall be valid for no
more than thirty (30) days from their date, unless otherwise
stated in the quotation. All quotations are subject to change
by Square D Company at any time upon notice to
Purchaser. It is Purchaser’s obligation to review the
quotation carefully and to immediately advise Square D in
writing of any differing interpretation Purchaser has so any
necessary change can be made.
3. PRICE POLICY: All prices are subject to change without
notice. In the event of a net price change and unless
otherwise agreed to in writing, prices for orders scheduled
for immediate release shall be those in effect at time of
order entry. Prices for orders placed for future shipment
without an agreed price and ship date will be billed at the
pricing in effect as of the shipment date. All clerical errors
are subject to correction.
4. SUBSTITUTION: Square D may furnish suitable
substitutes for material unobtainable because of priorities or
regulations established by governmental authority or nonavailability of materials from suppliers, provided such
substitutions do not adversely affect the technical
soundness of the equipment. Square D assumes no liability
for deviation from published dimensions and descriptive
information not essential to proper performance of the
product.
5. TAXES: Any manufacturer’s tax, retailer’s tax, occupation
tax, use tax, sales tax, excise tax, (except federal excise tax
© 2004 Schneider Electric
All Rights Reserved
6/7/04

on vehicles), duty, customs, inspecting or testing fee, or
other tax, fee or charge of any nature whatsoever, imposed
by any governmental authority or measured by any
transaction between Square D and Purchaser, shall be paid
by the Purchaser in addition to the prices quoted or
invoiced, and such charges will appear as a separate line
item on the invoice. In the event Square D will be required
to pay any such tax, fee, or charge, Purchaser shall
reimburse Square D or, in lieu of such payment, Purchaser
shall supply Square D at the time the order is submitted
with an exemption certificate or other document acceptable
to the tax authority. Purchase Orders must state the
existence and amount of any such tax, fee or charge for
which Purchaser claims an exemption.
6. TERMS OF PAYMENT: Acceptance of all Purchase Orders
is subject to Purchaser meeting Square D credit standards.
Terms are subject to change for failure to meet such
standards. Terms are net thirty (30) days from date of
invoice of each shipment, unless otherwise stated in
Square D’s quotation. For an authorized distributor or
authorized reseller order, applicable terms of payment are
stated in the quotation or applicable discount schedule.
Square D reserves the right at any time to demand full or
partial payment before proceeding with a contract of sale if,
in its sole judgment, as a result of changes in the financial
condition of the Purchaser the terms of payment originally
specified are no longer justified.
7. PAYMENTS: If delivery is delayed or deferred by the
Purchaser beyond the scheduled date, payment shall be
due in full when Square D is prepared to ship. The
equipment may be stored at the risk and expense of the
Purchaser. If the Purchaser defaults when any payment is
due, then the whole contract price shall become due and
payable upon demand, or Square D at its option, without
prejudice to other lawful remedies, may defer delivery or
cancel the contract for sale. If Purchaser becomes
insolvent, or bankrupt or in the event any proceeding is
brought against the Purchaser, voluntarily or involuntarily
under the bankruptcy or any insolvency law, Square D may
cancel any order outstanding at any time and recover its
applicable cancellation charges from the Purchaser or the
Purchaser’s estate.
8. DELIVERY:
A) F.O.B. POINT OF SHIPMENT: When the Square D
quotation is based on delivery F.O.B. point of shipment,
freight prepaid and allowed for delivery within the
continental United States, product is sold F.O.B. point of
shipment, freight prepaid and allowed. A shipping and
handling charge of twenty-five dollars ($25) will be
added to all orders having a total net invoice price of
less than one thousand dollars ($1,000). Delivery by
Square D to the point of shipment constitutes delivery
to the Purchaser; and title and all risk of loss or damage

(Continued)

Square D Conditions Of Sale
in transit shall pass to the Purchaser at time of delivery
at the F.O.B. point. Square D is not responsible for
breakage after having received “in good order” receipts
from the carrier. Purchaser is responsible for pursuing
any damage claims with the carrier. No allowance will
be made in lieu of transportation if the Purchaser
accepts shipment at factory, warehouse or freight
station or otherwise supplies its own transportation.
Freight prepaid is defined as: a) Shipments to
destinations within the continental United States to the
accessible common carrier point nearest the first
destination. b) Shipments to U.S. destinations outside
the continental United States shall be to the common
carrier free delivery point in the United States nearest
the original port of embarkation. All charges associated
with F.A.S., C.I.F., or other charges such as pier
transfer, lift, ocean freight, and marine or war insurance
shall be paid by the Purchaser, unless otherwise
specifically agreed in a specific Purchase Order. In no
event will Square D be responsible for demurrage or
detention charges.
B) DELIVERY: F.O.B. DESTINATION: When the
Square D quotation is based on delivery F.O.B.
Destination, for shipments for delivery within the
continental United States, Square D will retain title and
all risk of loss or damage in transit to the common
carrier free delivery point in the United States nearest
the first destination for a price addition of 2% of the net
price. If the Purchaser elects this option, Purchaser’s
obligations shall be as follows: a) Purchaser shall
have the responsibility of inspecting the equipment for
apparent loss or damage immediately upon its arrival at
the free delivery point. b) In the event of apparent
shipping loss or damage, Purchaser shall make written
notation of the loss on the carrier’s delivery receipt and,
within 72 hours of delivery shall notify the Square D
Customer Information Center. Purchaser shall not
remove product from the point of examination and shall
retain the shipping container and packing material.
Purchaser shall request the carrier to make an
inspection and send Square D a copy of the carrier’s
inspection report. c) In the event of concealed damage
which occurred during transit and is discovered by the
Purchaser after delivery, Purchaser shall report such
damage immediately, but in no event later than 15 days
after delivery, to the delivering carrier, and within 72
hours of discovery, shall notify the local Square D field
office. If such notification is not made, Square D shall
not be liable for loss or damage in transit.
C) SHIPMENT AND ROUTING: Square D shall select the
point of origin of shipment, the method of transportation
and the routing of the shipment. Purchasers that
request expedited or special modes of transportation or
routing involving air, premium or any other nonstandard Square D shipping shall be assessed
additional charges for shipping, handling, freight and
expediting. Any rebates, allowances, discounts or
incentives received by Square D from its carriers shall
be retained by Square D. All prices include domestic
packaging only. When other than domestic packaging is

(Continued)

required, contact your local Square D field office.
Purchaser specified packaging and marking may be
subject to additional charges.
9. SHORTAGES: Claims for shortages or errors must be
made in writing to Square D within 60 days after invoice
date, and failure to give such notice shall constitute
unqualified acceptance and a waiver of all such claims by
the Purchaser.
10. INSTALLMENTS: Square D reserves the right to make
shipments in installments, unless otherwise expressly
stipulated in a specific Purchase Order; and all such
installments when separately invoiced shall be paid for
when due per invoice without regard to subsequent
shipments. Delay in shipment of any installment shall not
relieve Purchaser of its obligation to accept remaining
shipments.
11. FORCE MAJEURE: Square D shall not be liable for any
damages as a result of any delays due to any causes
beyond Square D’s control, including, without limitation, an
act of God; act of Purchaser or Square D supplier; embargo
or other governmental act; regulation or request; fire;
accident; strike; slowdown; flood; fuel or energy shortage;
sabotage; war; riot; delay in transportation and inability to
obtain necessary labor, materials or manufacturing facilities
from usual sources. In the event of any such delay, the date
of delivery shall be extended for a period of time reasonably
necessary to overcome the effect of such delay.
12. STANDARD WARRANTY: Square D warrants equipment
manufactured by it and sold through authorized sales
channels to be free from defects in materials and
workmanship for eighteen (18) months from date of invoice
by Square D or its authorized sales channel. If within such
period any such equipment shall be proved to Square D’s
satisfaction to be non-conforming, such equipment shall be
repaired or replaced at Square D’s option. This warranty
shall not apply (a) to equipment not manufactured by
Square D, (b) to equipment that has been repaired or
altered by other than Square D so as, in its judgment, to
affect the same adversely, or (c) to equipment that has
been subjected to negligence, accident, or damage by
circumstances beyond Square D’s control, or improper
operation, maintenance or storage, or to other than normal
use or service. With respect to equipment not manufactured
by Square D, the warranty obligations of Square D shall in
all respects conform and be limited to the warranty actually
extended to Square D by its supplier. Non-conforming
products must be returned at Square D’s expense for
evaluation unless this is waived in writing. Replacement
products may be new or reconditioned. The foregoing
warranties do not cover reimbursement for labor,
transportation, removal, installation, temporary power, or
any other expenses that may be incurred in connection with
repair or replacement.
13. OPTIONAL WARRANTIES: (Only available on equipment
to be located in the U.S.) Option 1—Extended—2 or 3
years from Shipment. If requested by the Purchaser and
specifically accepted in writing by Square D, the standard
© 2004 Schneider Electric
All Rights Reserved
6/7/04

Square D Conditions Of Sale
warranty will be extended to two (2) years from date of
invoice for a price addition of 1% of the net face value of the
Purchase Order or will be extended for three (3) years from
date of invoice for a price addition of 3% of the net face
value of the Purchase Order. Option 2—Special
Warranty: If requested by the Purchaser and specifically
accepted in writing by Square D, the standard warranty will
be extended, for a price addition of 3% of the net face value
of the Purchase Order, to cover reimbursement of the direct
costs of: a) Removal of non-conforming equipment or part
thereof; b) Transporting equipment or parts to and from the
place of repair; c) Off-loading of truck and reinstallation at
the original site. Such special warranty, which may be
chosen to cover a period not exceeding that of the standard
or extended warranty (see above) selected, will not include
the cost of providing temporary power or removing or
replacing other apparatus or structures, or costs of
transportation beyond a common carrier free delivery point
in the continental United States. Further, the obligation of
Square D for expenses and costs arising under this special
warranty coverage will not exceed 50% of the net invoice
price on the equipment being repaired. This warranty does
not change or affect the allocation of risk or loss during
shipment. Option 3—Extended Warranty—Preventative
Maintenance Agreements: If requested by the Purchaser,
and specifically accepted by Square D, a Preventative
Maintenance Agreement is available to provide preventative
maintenance on equipment covered by the agreement.
Terms of the Preventative Maintenance Agreement shall be
as defined in a separate Services Agreement agreed to by
the parties.
14. RETURN OF EQUIPMENT: NO EQUIPMENT MAY BE
RETURNED WITHOUT FIRST OBTAINING SQUARE D’S
WRITTEN PERMISSION AND A RETURNED MATERIAL
IDENTIFICATION TAG. Returned equipment must be of
current manufacture, in the original packaging, unused,
undamaged and in saleable condition. Returned equipment
must be securely packed to reach Square D without
damage and labeled with the return authorization number.
Any cost incurred by Square D to put equipment in first
class condition will be charged to the Purchaser. Purchaser
requested returns not involving a Square D error will be
assessed Square D's standard restocking fee. Returns will
be credited at the pricing specified in Square D's standard
return policy. Special Order and Custom equipment is not
returnable. Square D shall bear the cost of returns resulting
from Square D error, and method and route of return will be
at the discretion of Square D. Costs incurred by failure to
follow Square D direction will be borne by the Purchaser.
15. SOFTWARE: Any software or computer information, in
whatever form that is provided with equipment
manufactured by Square D, is licensed to Purchaser solely
pursuant to standard licenses of Square D or its supplier of
such software or computer information which licenses are
hereby incorporated by reference. Square D does not
warrant that such software or computer information will
operate error free or without interruption, and warrants only
that during the warranty period applicable to the equipment
that the software will perform the essential functions
© 2004 Schneider Electric
All Rights Reserved
6/7/04

necessary for the normal and customary operation of the
equipment. If such software or computer information fails to
conform to such warranty, Square D will, at its option,
provide an update to correct the non-conformance or
replace the software or computer information with the latest
available version containing a correction. Square D shall
have no obligation to provide updates or revisions.
16. LIMITATIONS: These disclaimers and limitations of
remedies apply to all warranties offered to Purchaser and
to all Purchase Orders. THE WARRANTIES SET FORTH
ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
EXPRESSED OR IMPLIED WARRANTIES (EXCEPT
WARRANTIES OF TITLE), INCLUDING, BUT NOT
LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Except as may be expressly provided in an authorized
writing by Square D, Square D shall not be subject to any
other obligations or liabilities whatsoever, other than as
stated above with respect to equipment sold or services
rendered by Square D. Notwithstanding anything to the
contrary herein contained SQUARE D COMPANY, ITS
CONTRACTORS AND SUPPLIERS OF ANY TIER,
SHALL NOT BE LIABLE IN CONTRACT, IN TORT
(INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR
OTHERWISE FOR LOST TIME, LOST PROFITS, OR
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND WHATSOEVER.
The remedies of the Purchaser are exclusive and the total
cumulative liability of Square D, its contractors and
suppliers of any tier, with respect to this contract or anything
done in connection therewith, such as the use of any
product covered by or furnished under the contract,
whether in contract, in tort (including negligence or strict
liability) or otherwise, shall not exceed the price of the
product, part, or service on which such liability is based.
17. INTELLECTUAL PROPERTY: As to equipment proposed
and furnished by Square D, Square D shall defend any suit
or proceeding brought against Purchaser so far as based
on a claim that such equipment constitutes an infringement
of any copyright, trademark or patent of the United States.
This obligation shall be effective only if Purchaser shall
have made all payments then due hereunder and if
Square D is notified promptly in writing and given authority,
information, and assistance at Square D’s expense for the
defense of the same. In the event the use of such
equipment by Purchaser is enjoined in such a suit,
Square D shall, at its expense, and at its sole option, either
(a) procure for the Purchaser the right to continue using
such equipment (b) modify such equipment to render it
non-infringing (c) replace such equipment with noninfringing equipment, or (d) refund the purchase price (less
depreciation) and the transportation and installation costs
of such equipment. Square D will not be responsible for any
compromise or settlement made without its written consent.
The foregoing states the entire liability of Square D for
patent, trademark or copyright infringement, and in no
event shall Square D be liable if any infringement charge is
based on the use of Square D equipment for a purpose
other than that for which it was sold by Square D. As to any

(Continued)

Square D Conditions Of Sale
equipment furnished by Square D to Purchaser and
manufactured in accordance with designs proposed by
Purchaser, the Purchaser shall indemnify Square D against
any award made against Square D for patent, trademark, or
copyright infringements.
18. WITNESS OF TESTS AND FACTORY INSPECTIONS:
Normal production schedules do not provide the
opportunity for Purchaser to witness routine factory tests on
equipment or make factory inspections. Witnessing of
tests or factory inspections by the Purchaser may
result in delays of production for which Square D will
not be responsible. Witness testing and factory
inspections must be requested at time of quotation, are
subject to additional costs and must be confirmed at
order entry. Standard Square D factory testing and
inspection will apply. Square D will notify Purchaser
fourteen (14) calendar days prior to scheduled witness
testing or inspection. In the event Purchaser is unable to
attend, the Parties may mutually agree on a rescheduled
date. However, Square D, at its sole option, may consider
the witness tests and/or inspection waived, and ship and
invoice the Products and the witness testing charges.
Purchaser will be responsible for paying for all scheduled
witness testing, whether or not Purchaser attends.
19. NUCLEAR APPLICATIONS TERMS AND CONDITIONS:
Unless otherwise agreed in writing by a duly authorized
representative of Square D, products sold hereunder are
not intended for use in or in connection with any nuclear
facility or activity. If so used, Square D disclaims all liability
for any damage, injury or contamination arising from a
nuclear incident or nuclear hazard; and Purchaser shall
indemnify Square D against any such liability, whether
arising as a result of breach of contract, warranty or tort
(including negligence) or otherwise.

20. PATTERNS AND TOOLS: Notice will be given if special
patterns or tools are required to complete any order.
Charges for such patterns or tools do not convey title
thereto or the right to remove them from Square D’s plant. If
patterns or tools are not used for a period of two years,
Square D shall have the right to scrap them without notice.
21. PRODUCT NOTICES: Purchaser shall promptly supply the
user (including its employees) of the product with all
Square D supplied product notices, warnings, instructions,
recommendations and similar materials.
22. ERRORS: Square D reserves the right to correct errors or
omissions in quotations, acknowledgments, invoices, or
other documents.
23. OSHA COMPLIANCE: Compliance with OSHA or similar
federal, state or local laws during the operation or use of the
product(s) is the sole responsibility of the Purchaser.
24. TERMINATION: Any order may be terminated by the
Purchaser only upon written notice to Square D and upon
payment of reasonable and proper termination charges
based on the price of the terminated order and
reimbursement of all direct costs and expenses associated
with the order caused by such termination and shall include
a reasonable profit. Special or custom ordered equipment
is not cancelable after final acceptance of approval
drawings for the commencement of manufacturing.
25. CANCELLATION: Square D shall have the right to cancel
any order or contract at any time by written notice for any
material breach of the contract by the Purchaser, including
material delays in releasing equipment for manufacture or
approval drawings and excessive changes to specifications
or drawings.

© 2004 Schneider Electric
All Rights Reserved
6/7/04

F R A C T I O N ,

D E C I M A L ,

A N D

FRACTIONS TO DECIMALS TO MILLIMETERS

M I L L I M E T E R E Q U I V A L E N T S
C O N V E R S I O N T A B L E S
MILLIMETERS TO INCHES

Fractions

Decimals

Millimeters

Millimeters

Inches

Millimeters

Inches

1/64
1/32
3/64
1/16

0.015625
0.03125
0.046875
0.0625

0.397
0.794
1.191
1.588

5/64
3/32
7/64
1/8

0.078125
0.09375
0.109375
0.1250

1.984
2.381
2.778
3.175

0.1
0.2
0.3
0.4
0.5

0.0039
0.0079
0.0118
0.0157
0.0197

46
47
48
49
50

1.8110
1.8504
1.8898
1.9291
1.9685

9/64
5/32
11/64
3/16

0.140625
0.15625
0.171875
0.1875

3.572
3.969
4.366
4.763

0.6
0.7
0.8
0.9

0.0236
0.0276
0.0315
0.0354

51
52
53
54
55

2.0079
2.0472
2.0866
2.1260
2.1654

13/64
7/32
15/64
1/4

0.203125
0.21875
0.234375
0.2500

5.159
5.556
5.953
6.350

1
2
3
4
5

0.0394
0.0787
0.1181
0.1575
0.1969

56
57
58
59
60

2.2047
2.2441
2.2835
2.3228
2.3622

17/64
9/32
19/64
5/16

0.265625
0.28125
0.296875
0.3125

6.747
7.144
7.541
7.938

6
7
8
9
10

0.2362
0.2756
0.3150
0.3543
0.3937

61
62
63
64
65

2.4016
2.4409
2.4803
2.5197
2.5591

21/64
11/32
23/64
3/8

0.328125
0.34375
0.359375
0.3750

8.334
8.731
9.128
9.525

25/64
13/32
27/64
7/16

0.390625
0.40625
0.421875
0.4375

9.922
10.319
10.716
11.113

11
12
13
14
15

0.4331
0.4724
0.5118
0.5512
0.5906

66
67
68
69
70

2.5984
2.6378
2.6772
2.7165
2.7559

29/64
15/32
31/64
1/2

0.453125
0.46875
0.484375
0.500

11.509
11.906
12.303
12.700

16
17
18
19
20

0.6299
0.6693
0.7087
0.7480
0.7874

71
72
73
74
75

2.7953
2.8346
2.8740
2.9134
2.9528

33/64
17/32
35/64
9/16

0.515625
0.53125
0.546875
0.5625

13.097
13.494
13.891
14.288

21
22
23
24
25

0.8268
0.8661
0.9055
0.9449
0.9843

76
77
78
79
80

2.9921
3.0315
3.0709
3.1102
3.1496

37/64
19/32
39/64
5/8

0.578125
0.59375
0.609375
0.6250

14.684
15.081
15.478
15.875

41/64
21/32
43/64
11/16

0.640625
0.65625
0.671875
0.6875

16.272
16.669
17.066
17.463

26
27
28
29
30

1.0236
1.0630
1.1024
1.1417
1.1811

81
82
83
84
85

3.1890
3.2283
3.2677
3.3071
3.3465

45/64
23/32
47/64
3/4

0.703125
0.71875
0.734375
0.7500

17.859
18.256
18.653
19.050

31
32
33
34
35

1.2205
1.2598
1.2992
1.3386
1.3780

86
87
88
89
90

3.3858
3.4252
3.4646
3.5039
3.5433

49/64
25/32
51/64
13/16

0.765625
0.78125
0.796875
0.8125

19.447
19.844
20.241
20.638

36
37
38
39
40

1.4173
1.4567
1.4961
1.5354
1.5748

91
92
93
94
95

3.5827
3.6220
3.6614
3.7008
3.7402

53/64
27/32
55/64
7/8

0.828125
0.84375
0.859375
0.8750

21.034
21.431
21.828
22.225

41
42
43
44
45

1.6142
1.6535
1.6929
1.7323
1.7717

96
97
98
99
100

3.7795
3.8189
3.8583
3.8976
3.9370

57/64
29/32
59/64
15/16

0.890625
0.90625
0.921875
0.9375

22.622
23.019
23.416
23.813

61/64
31/32
63/64
1

0.953125
0.96875
0.984375
1.000

24.209
24.606
25.003
25.400

Customer
I N F O R M A T I O N

C E N T E R

One toll-free number to call to get all the information you need.

Monday-Friday 8:00 a.m. - 8:00 p.m. EST

1 - 8 8 8 - SQUARED

The Square D Customer Information Center (CIC) is the single point of
contact where qualified personnel answer your customer service and
technical support questions.
Serving all Square D authorized distributors and customers in the U.S.

(1-888-778-2733)

Technology
W I T H O U T

B O U N D A R I E S

The Square D Multi-Link Structured Wiring System....
a complete network solution
The Square D Multi-Link System provides a complete network solution
designed to make life more mobile, more flexible, and more convenient.
Providing voice, data and video connectivity throughout the home, the
Multi-Link System allows you to share entertainment equipment, monitor areas
of the home, and exchange data through a series of connected networks.

W W W . S Q U A R E D . C O M
For all of your current selection and specification
information needs
DigestPlus SelectorTM is the most advanced product selection tool in the
industry. This intuitive, on-line selection tool will add value to your business
by simplifying your design, specifying and purchasing processes.
■ Product Categories - browse by product
■ Alphabetical Listing - browse by product
■ Merchandise Product Selector - select by characteristics
With access to all of the most up-to-date technical documentation and
merchandise drawings to support your design and specification requirements,
the Square D website is a virtual workzone.
The shopping cart feature will save you time by allowing you to print to your
laser printer or e-mail to your Square D distributor.

Schneider Electric North American Operating Division
1415 S. Roselle Road
Palatine, IL 60067
Tel: 847-397-2600
Fax: 847-925-7500
0110PL9401R5/04 (Replaces 0110PL9401R11/01)

5-04

©2004 Schneider Electric. All rights reserved.

■ Search - by text or catalog number



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Create Date                     : 2004:06:08 16:05:21Z
Modify Date                     : 2004:10:12 08:19:31-07:00
Page Count                      : 72
Creation Date                   : 2004:06:08 16:05:21Z
Mod Date                        : 2004:10:12 08:19:31-07:00
Producer                        : Acrobat Distiller 5.0.5 for Macintosh
Author                          : Big Daniel
Metadata Date                   : 2004:10:12 08:19:31-07:00
Creator                         : Big Daniel
Title                           : Resi 2004.fm
Has XFA                         : No
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools

Navigation menu