Cct 04c

2014-09-05

: Pdf 196612-Attachment 196612-Attachment 784550 Batch7 unilog

Open the PDF directly: View PDF PDF.
Page Count: 32

“Made with pride in the USA”
Catalog
CCT-11A
Fusing chart update
Effective Date:
June 10, 2011
Supercedes: CCT-10B
MICRON INDUSTRIES CATALOG CCT-11A
REPLACES CCT-10B
Table of Contents
THE MICRON EDGE 3
- Warranty
Transformer Selection Process 4-5
Standards 6
-UL/CSA
-CUL
-IEC
Control Transformers
Series 2 ImperviTRAN & ImperviTRAN 8-13
-Connection Diagrams 14
-Accessories 15-17
Overcurrent Protection Tables (UPDATED)
18
GlobalTRAN 19-24
-Connection Diagrams 25
Medium Voltage 26
Power Supplies
DINergy Power Supplies 27-29
LVGP
-Overview 30
Notes 31
2 MICRON POWER DELIVERY
THE MICRON EDGE
While other manufacturers
treat transformers as
just one of a variety of
products, transformers
are THE major product
focus for Micron
This focus and resulting
commitment to excellence,
exemplified in our
unprecedented 20-year
warranty¹, has made
Micron
#1
with specifiers of
transformers
for over 30 years.
¹ 20 years applies to all 600 volt class Control
Transformer product. LVGP and Medium Voltage
are waranted for one year, Power Supplies for five.
3 MICRON POWER DELIVERY
TRANSFORMER SELECTION
PROCESS
Determining Inrush and Voltage
Requirements
Selecting a transformer for
industrial control circuit
applications requires
knowledge of the following
terms:
INRUSH VA is the product
of the load voltage (V)
multiplied by the current (A)
that is required during start-
up. It is calculated by adding
the inrush VA requirements
of all devices (contactors,
timers, relays, pilot lights,
solenoids, etc.), which will
be energized together.
Inrush VA requirements are
best obtained from the
component manufacturer.
SEALED VA also called
Steady State VA, is the
product of the load voltage
(V) multiplied by the current
(A) that is required to
operate the circuit after
initial start-up or under
normal operating conditions.
It is calculated by adding the
sealed VA requirements of
all electrical components of
the circuit that will be
energized at any given time.
Sealed VA requirements are
best obtained from the
component manufacturer.
PRIMARY VOLTAGE is
the voltage available from
the electrical distribution
system and its operational
frequency, which is
connected to the transformer
supply voltage (H) terminals.
SECONDARY VOLTAGE
is the voltage required for
load operation, which is
connected to the transformer
load voltage (X) terminals.
Once the circuit variables
have been determined,
transformer selection is a
simple 5-step process as
follows:
1. Determine the
Application Inrush
VA by using the
following industry
accepted formula.
Application Inrush VA = (INRUSH
VA)² + (SEALED VA)²
2. Refer to the
Regulation Data
Chart. If the primary
voltage is basically
stable and does not
vary by more than
5% from nominal, the
4 MICRON POWER DELIVERY
REGULATION DATA CHART
Transformer Inrush VA at 20% Power factor
VA Rating NEMA / IEC NEMA / IEC NEMA / IEC To comply with NEMA standards, which require
95% Sec. 90% Sec. 85% Sec. all magnetic devices to operate successfully at 85%
Voltage Voltage Voltage of rated voltage, the 90% secondary column is
25¹100 / ---- 130 / --- 150 / --- most often used in selecting a transformer. No
50¹170 / 190 200 / 220 240 / 270 comparable requirement is available for IEC.
75¹310 / 350 410 / 460 540 / 600
100¹370 / 410 540 / 600 730 / 810
150²780 / 850 930 / 1030 1150 / 1270
200²810 / 900 1150 / 1270 1450 / 1600
250²1400 / 1540 1900 / 2090 2300 / 2530
300²1900 / 2090 2700 / 2970 3850 / 4240
350²3100 / 3410 3650 / 4020 4800 / 5280
500²4000 / 4400 5300 / 5830 7000 / 7700
750²8300 / 9130 11000 / 12100 14000 / 15400
1000²15000 / 16500 21000 / 23000 27000 / 29500
1000³ 9000 / 9900 13000 / 14300 18500 / 20300
1500³10500 / 11500 15000 / 16500 20500 / 22500
2000³17000 / 18900 25500 / 27300 34000 / 36400
3000³24000 / 25700 36000 / 38500 47500 / 50200
5000³55000 / 58800 92500 / 98900 115000 / 122000
¹ For units with class 105° C insulation system.
² For units with class 130° C insulation system.
³ For units with class 180° C insulation system
5 MICRON POWER DELIVERY
INDUSTRY AND INTERNATIONAL
STANDARDS
Micron offers a broad line of standard transformers, each made with the
finest materials and workmanship. Laminations of high-grade silicon
steel assure optimum performance and the finest quality copper magnet
wire assures efficient operation. Insulation materials are of the highest
rating available for the temperature class and mounting brackets of
heavy gauge steel add strength and stability. All are UL 506 listed (File
# E46323) and either C-UL or CSA certified (File # LR27533) and meet
NEMA and ANSI requirements.
In response to the change in compliance standards for CE marking of
industrial control transformers as required by IEC/EN guidelines,
Micron has introduced new GlobalTRAN models in compliance with
EN61558-2. This new IEC/EN standard replaces the previous IEC/EN
60742 standard for control power transformers that expired on
December 31, 2003. The Micron design engineering department has
produced 61558-2 compliant designs that permit the customer to retain
mounting layouts used for the previous Micron 60742 designs.
GlobalTRAN® products carry the CE mark, certifying 100%
compliance with requirements of EN61558 for Non-Short Circuit Proof
Isolating Transformers. GlobalTRAN control transformers feature
touch-proof terminals, utilizing either Micron's SafeTouch terminal
covers or a touch-proof terminal block, and meet true IP-20 or IP-00
terminal protection ratings as defined by IEC-529.
Of course, all GlobalTRAN products carry either UL listing and CSA
certification or cUL.
GlobalTRAN is the most reliable and versatile control transformer in the
industry today.
DINergy™ products are designed to meet the most stringent
international specifications for safety and EMI; and are designed to
compact dimensions. All carry C-UL certification to UL60950 and
UL508 plus the CE mark signifying certification to EN60950, EN
55022B, EN 61000-3-2 and IEC610004-2, 3, 4, 5, 6, 8, 11.
ImperviPOWER 67 products are designed to meet the most stringent
international specifications; and are designed to compact dimensions.
All carry certification to UL60950, CSA 22.2, EN60950, EN 55011, EN
6100-6, EN6000-6-2, -4-2, -4-3, -4-4, -4-5, -4-6 and -4-11.
6 MICRON POWER DELIVERY
IMPERVITRAN
SIMPLY – THE MOST VERSATILE AVAILABLE
SEMS screw terminal strips as an integral part of the coil bobbin
 Allows bare wire and terminal connection methods
 Easily adaptable to slot, Phillips and hex driver tools
 Robust physical support instead of “floating” terminal strips
UL/CSA or C-UL Family Listing
 Absolute flexibility of design for 600 volt class product
Integral accessory mounting plate on transformer top
 Allows field modification to block-style primary fusing
Fully encapsulated coil
Reduces SKU count for fused/non-fused applications
Tough environment-proof construction  Provides mounting platform for additional items (DIN Rail)
Eases wire routing around the transformer
Standard strap brackets or optional mounting plate
Fusion-welded coil terminations instead of solder joints
 Features a superior weld result for vibration-resistant stability
Eliminates cold solder joint breakage, improves conductivity Offers common mounting template across a wide range of voltages
 Provides a lead-free RoHS compliant construction  Alternate plates available for OEM volumes
Face-on terminal labels with large schematic indicators
IP-20 cover kits available
 Terminal designations clearly visible to the installer and technician Quickly convertible to an IP-20 safety level
 Indicators aligned with terminal screws for clarity
ImperviTRAN's feature-laden Series 2 design. Developed to
address ALL customer needs with a product designed in a
highly efficient manner. ImperviTRAN designs span over 35
years of market leadership.
CONTROL TRANSFORMERS
GENERAL SPECIFICATIONS:
STYLE: SERIES 2 IMPERVITRAN STYLE: IMPERVITRAN (NOT SERIES 2)
APPROVALS: UL/Cul FILE# E46323 APPROVALS: UL LISTED FILE# E46323/ CSA APPROVED FILE# LR27533
TEMP CLASS: 105°C/130°C TEMP CLASS: 105°C/130°C/180°C
VA SIZES: 50-1500 VA SIZES: 1000-5000 TERMINAL TORQUE:
SUFFIX DESCRIPTION: ALL IMPERVITRAN PRODUCT
"K" IN SUFFIX DENOTES INSTALLED SECONDARY FUSE CLIPS
"R" IN SUFFIX DENOTES INSTALLED CLASS "CC" PRIMARY FUSE BLOCK
30A: 20 INCH-POUNDS
TWO LETTER SUFFIX = TEMP CLASS 105C >30A: 30 INCH-POUNDS
THREE LETTER SUFFIX ENDING "F" = TEMP CLASS 130C
THREE LETTER SUFFIX ENDING "H" = TEMP CLASS 180C
CATALOG CATALOG CATALOG
NUMBER NUMBER NUMBER
GROUP "A" GROUP "C" GROUP "F"
VOLTAGE: VOLTAGE: VOLTAGE:
PRI: 220x440, 230x460, 240x480 PRI: 120x240 PRI: 208/277
SEC: 110/115/120 SEC: 24 SEC: 120
VA AMPS VA AMPS VA AMPS
B050BTZ13JK 50 0.43 B050LP7JK 50 2.08 B050MQ15XK 50 0.42
B050BTZ13RB B050LP7RB B050MQ15RK
B075BTZ13JK 75 0.65 B075LP7JK 75 3.13 B075MQ15XK 75 0.63
B075BTZ13RB B075LP7RB B075MQ15RK
B100BTZ13JK 100 0.87 B100LP7JK 100 4.17 B100MQ15XK 100 0.83
B100BTZ13RB B100LP7RB B100MQ15RK
B150BTZ13JKF 150 1.30 B150LP7JKF 150 6.25 B150MQ15XKF 150 1.25
B150BTZ13RBF B150LP7RBF B150MQ15RKF
B200BTZ13JKF 200 1.74 B200LP7JKF 200 8.33 B200MQ15XKF 200 1.67
B200BTZ13RBF B200LP7RBF B200MQ15RKF
B250BTZ13JKF 250 2.17 B250LP7JKF 250 10.42 B250MQ15XKF 250 2.08
B250BTZ13RBF B250LP7RBF B250MQ15RKF
B300BTZ13JKF 300 2.61 B300LP7JKF 300 12.50 B300MQ15XKF 300 2.50
B300BTZ13RBF B300LP7RBF B300MQ15RKF
B350BTZ13JKF 350 3.04 B350LP7JKF 350 14.58 B350MQ15XKF 350 2.92
B350BTZ13RBF B350LP7RBF B350MQ15RKF
B500BTZ13JKF 500 4.35 B500LP7JKF 500 20.83 B500MQ15XKF 500 4.17
B500BTZ13RBF B500LP7RBF B500MQ15RKF
B750BTZ13JKF 750 6.52 B750LP7JKF 750 31.25 B750MQ15XKF 750 6.25
B750BTZ13RBF B750LP7RBF B750MQ15RKF
B1K0BTZ13JKF 1000 8.70
B1K0BTZ13RBF GROUP "G"
B1K5BTZ13JKF 1500 13.04 VOLTAGE:
B1K5BTZ13RBF PRI: 208/230/460
B2K0BTZ13JKH 2000 17.39 SEC: 115
B2K0BTZ13RBH B050MBT13XK 50 0.43
B3K0BTZ13JXH 3000 26.09 B050MBT13RK
B5K0BTZ13JXH 5000 43.48 B075MBT13XK 75 0.65
B075MBT13RK
GROUP "B" GROUP "E" B100MBT13XK 100 0.87
VOLTAGE: VOLTAGE: B100MBT13RK
PRI: 240x480 PRI: 550/575/600 B150MBT13XKF 150 1.30
SEC: 24 SEC: 110/115/120 B150MBT13RKF
B050PU7JK 50 2.08 B050WZ13XK 50 0.43 B200MBT13XKF 200 1.74
B050PU7RB B050WZ13RK B200MBT13RKF
B075PU7JK 75 3.13 B075WZ13XK 75 0.65 B250MBT13XKF 250 2.17
B075PU7RB B075WZ13RK B250MBT13RKF
B100PU7JK 100 4.17 B100WZ13XK 100 0.87 B300MBT13XKF 300 2.61
B100PU7RB B100WZ13RK B300MBT13RKF
B150PU7JKF 150 6.25 B150WZ13XKF 150 1.30 B350MBT13XKF 350 3.04
B150PU7RBF B150WZ13RKF B350MBT13RKF
B200PU7JKF 200 8.33 B200WZ13XKF 200 1.74 B500MBT13XKF 500 4.35
B200PU7RBF B200WZ13RKF B500MBT13RKF
B250PU7JKF 250 10.42 B250WZ13XKF 250 2.17 B750MBT13XKF 750 6.52
B250PU7RBF B250WZ13RKF B750MBT13RKF
B300PU7JKF 300 12.50 B300WZ13XKF 300 2.61 B1K0MBT13XKF 1000 8.70
B300PU7RBF B300WZ13RKF B1K0MBT13RKF
B350PU7JKF 350 14.58 B350WZ13XKF 350 3.04 B1K5MBT13XKF 1500 13.04
B350PU7RBF B350WZ13RKF B1K5MBT13RKF
B500PU7JKF 500 20.83 B500WZ13XKF 500 4.35 B2K0MBT13XKH 2000 17.39
B500PU7RBF B500WZ13RKF B2K0MBT13RKH
B750PU7JKF 750 31.25 B750WZ13XKF 750 6.52 B3K0MBT13XXH 3000 26.09
B750PU7RBF B750WZ13RKF B5K0MBT13XXH 5000 43.48
8 MICRON POWER DELIVERY
CONTROL TRANSFORMERS
STYLE: SERIES 2 IMPERVITRAN STYLE: IMPERVITRAN (NOT SERIES 2)
CATALOG CATALOG CATALOG
NUMBER NUMBER NUMBER
GROUP "H" GROUP "J" GROUP "K"
VOLTAGE:
VOLTAGE:
VOLTAGE:
PRI: 230/460/575 PRI: 208/230/460 PRI: 240x480
SEC: 95/115 SEC: 24/115 SEC: 120x240
VA AMPS VA AMPS VA AMPS
B050BTW37XX 50 0.53/0.44 B050-2000-1 50 2.08/0.44 B050PU1519JJ 50 0.42/0.21
B050BTW37RX B050-2000-8 B050PU1519RR
B075BTW37XX 75 0.79/0.65 B075-2001-1 75 3.13/0.65 B075PU1519JJ 75 0.63/0.31
B075BTW37RX B075-2001-8 B075PU1519RR
B100BTW37XX 100 1.05/0.87 B100-2002-1 100 4.17/0.87 B100PU1519JJ 100 0.83/0.42
B100BTW37RX B100-2002-8 B100PU1519RR
B150BTW37XXF 150 1.58/1.30 B150-2003-1F 150 6.25/1.30 B150PU1519JJF 150 1.25/0.63
B150BTW37RXF B150-2003-8F B150PU1519RRF
B200BTW37XXF 200 2.11/1.74 B200-2004-1F 200 8.33/1.74 B200PU1519JJF 200 1.67/0.83
B200BTW37RXF B200-2004-8F B200PU1519RRF
B250BTW37XXF 250 2.63/2.17 B250-2005-1F 250 10.42/2.17 B250PU1519JJF 250 2.08/1.04
B250BTW37RXF B250-2005-8F B250PU1519RRF
B300BTW37XXF 300 3.16/2.61 B300-2006-1F 300 12.50/2.61 B300PU1519JJF 300 2.50/1.25
B300BTW37RXF B300-2006-8F B300PU1519RRF
B350BTW37XXF 350 3.68/3.04 B350-2007-1F 350 14.58/3.04 B350PU1519JJF 350 2.92/1.46
B350BTW37RXF B350-2007-8F B350PU1519RRF
B500BTW37XXF 500 5.26/4.35 B500-2008-1F 500 20.84/4.35 B500PU1519JJF 500 4.17/2.08
B500BTW37RXF B500-2008-8F B500PU1519RRF
B750BTW37XXF 750 7.89/6.52 B750-2009-1F 750 31.3/6.5 B750PU1519JJF 750 6.25/3.12
B750BTW37RXF B750-2009-8F B750PU1519RRF
B1K0BTWZ37XKH 1000 10.53/8/70 B1K0-2010-1F 1000 41.7/8.7
B1K0BTWZ37RKH B1K0-2010-8F
B1K5BTWZ37XKH 1500
15.79/13.04
B1K5BTWZ37RKH
B2K0BTWZ37XKH 2000
21.05/17.39
B2K0BTWZ37RKH
B3K0BTWZ37XXH 3000
31.58/26.09
B5K0BTWZ37XXH 5000
52.63/43.48
GROUP "I" GROUP "J"
VOLTAGE: USE SERIES 2 GROUP "J" (ABOVE)
PRI: 380/400/415 FOR NEW APPLICATIONS!
SEC: 110x220 VOLTAGE:
VA AMPS PRI: 208/230/460
B050RFD34XJ 50 0.46/0.23 SEC: 24/115
B050RFD34RJ VA AMPS
B075RFD34XJ 75 0.68/0.34 B050MBT713XK 50 2.08/0.44
B075RFD34RJ B050MBT713RK
B100RFD34XJ 100 0.91/0.46 B075MBT713XK 75 3.13/0.65
B100RFD34RJ B075MBT713RK
B150RFD34XJF 150 1.37/0.69 B100MBT713XK 100 4.17/0.87
B150RFD34RJF B100MBT713RK
B200RFD34XJF 200 1.82/0.91 B150MBT713XKF 150 6.25/1.30
B200RFD34RJF B150MBT713RKF
B250RFD34XJF 250 2.28/1.14 B200MBT713XKF 200 8.33/1.74
B250RFD34RJF B200MBT713RKF
B300RFD34XJF 300 2.72/1.36 B250MBT713XKF 250 10.42/2.17
B300RFD34RJF B250MBT713RKF
B350RFD34XJF 350 3.18/1.59 B300MBT713XKF 300 12.50/2.61
B350RFD34RJF B300MBT713RKF
B500RFD34XJF 500 4.55/2.27 B350MBT713XKF 350 14.58/3.04
B500RFD34RJF B350MBT713RKF
B750RFD34XJF 750 6.82/3.41 B500MBT713XKF 500 20.84/4.35
B750RFD34RJF B500MBT713RKF
9 MICRON POWER DELIVERY
CONTROL TRANSFORMERS
CATALOG STYLE: IMPERVITRAN (NOT SERIES 2)
NUMBER STYLE: SERIES 2 IMPERVITRAN
GROUP "L" VOLTAGE:
PRI: 208-600
SEC: 85-130
VA AMPS
B050-0482-1 50 0.38
B050-0482-8
B100-0483-1 100 0.77
B100-0483-8
B150-0484-1F 150 1.15
B150-0484-8F
B250-0485-1F 250 1.92
B250-0485-8F
B350-0486-1F 350 2.69
B350-0486-8F
B500-0487-1F 500 3.85
B500-0487-8F
B750-0488-1F 750 5.77
B750-0488-8F
GROUP "M" VOLTAGE:
PRI: 240x480, 230x460, 220x440
SEC: 120x240, 115x230, 110x220
VA AMPS
B1K0-0500-3F 1000 8.70/4.35
B1K5-0501-3H 1500 13.04/6.52
B2K0-0502-3H 2000 17.39/8.70
B3K0-0503-3H 3000 26.09/13.04
B5K0-0504-3H 5000 43.48/21.74
GROUP "N" VOLTAGE:
PRI: 240, 347, 380
SEC: 120x240
VA AMPS
B1K0-0321-3F 1000 8.33/4.17
B1K5-0322-3H 1500 12.50/6.25
B2K0-0323-3H 2000 16.67/8.33
B3K0-0324-3H 3000 25.00/12.50
B5K0-0325-3H 5000 41.67/20.83
GROUP "P" VOLTAGE:
PRI: 120x240
SEC: 120x240
VA AMPS
B050LP1519JJ 50 0.42/0.21
B100LP1519JJ 100 0.83/0.42
B150LP1519JJF 150 1.25/0.63
B250LP1519JJF 250 2.08/1.04
B350LP1519JJF 350 2.92/1.46
B500LP1519JJF 500 4.17/2.08
B750LP1519JJF 750 6.25/3.12
10 MICRON POWER DELIVERY
DIMENSIONAL DATA
NOTE:
SERIES 2 AND IMPERVITRAN
TERMINAL BLOCK CAN HAVE
4 OR 6 TERMINALS AS NOTED.
PRIMARY FUSE BLOCK ADDS
1.375" (35MM) TO "C" DIMENSION.
A D C B E
(MATCHED DIMENSIONS)
NOTE: DIMENSION"C"' IS A MAXIMUM DIMENSION. IF SECONDARY FUSE CLIPS ARE
CATALOG GROUPS INCLUDED IN DESIGN, DEDUCT A MAXIMUM OF 0.50 (12.7MM) TO REMOVE.
A, B, C, E, F, G*, H*, I, K, P ALWAYS REQUEST CURRENT FACTORY DRAWING FOR FINAL REFERENCE.
VOLTAGE GROUPS
BTZ13, PU7, LP7, WZ13, MQ15, DIMENSIONS INCHES/MM
MBT13, BTW37, RFD34, PU1519,
A B C D E APPROX
LP1519 SERIES 2 (MAX) ALL VERSIONS MAXIMUM CENTERS WEIGHT
VA IN MM IN MM IN MM IN MM IN MM LBS
50 4-TERM 3.78 96 3.00 76 3.14 79 1.96 50 2.50 64 3.00
75 4-TERM 4.03 102 3.00 76 3.14 79 2.42 62 2.50 64 4.00
100 4-TERM 4.03 102 3.38 86 3.46 86 2.42 62 2.82 71 5.20
150 4-TERM 4.03 102 3.75 95 3.77 96 2.82 71 3.13 79 6.00
200 4-TERM 4.38 111 4.50 114 4.40 112 2.42 62 3.75 95 8.00
250 4-TERM 4.38 111 4.50 114 4.40 112 2.82 71 3.75 95 10.00
300 4-TERM 4.75 121 4.50 114 4.40 112 3.18 81 3.75 95 12.00
350 4-TERM 4.75 121 4.50 114 4.40 112 3.75 95 3.75 95 14.00
500 6-TERM 6.11 155 5.25 133 5.14 131 3.88 99 4.38 111 16.00
750 6-TERM 7.61 193 5.25 133 5.14 131 5.38 137 4.38 111 28.00
* GROUP "G" MATCHES IN 75, 150 & 250VA.
G
50 4-TERM 3.78 96 3.00 76 3.14 79 2.21 56 2.50 64 3.50
100 4-TERM 4.00 102 3.38 86 3.46 86 2.62 67 2.82 71 5.70
200 4-TERM 4.38 111 4.50 114 4.40 112 2.82 71 3.75 95 7.00
300 4-TERM 4.75 121 4.50 114 4.40 112 3.75 95 3.75 95 11.00
350 4-TERM 5.75 146 4.50 114 4.40 112 4.72 120 3.75 95 13.00
500 6-TERM 6.11 155 5.25 133 5.14 131 4.38 111 4.38 111 15.00
750 6-TERM 7.61 193 5.25 133 5.14 131 5.87 149 4.38 111 28.00
* GROUP "H" MATCHES IN 200, 250, 300 & 500VA
H
50 4-TERM 4.03 102 3.00 76 2.72 69 2.20 56 2.50 64 3.50
75 4-TERM 4.53 115 3.00 76 2.72 69 2.62 67 2.50 64 4.50
100 4-TERM 4.03 102 3.75 95 3.36 85 2.82 71 3.13 79 6.00
150 4-TERM 4.53 115 3.75 95 3.36 85 3.18 81 3.75 95 7.70
350 4-TERM 5.00 127 4.50 114 3.97 101 3.75 95 3.75 95 16.50
750 6-TERM 8.11 206 5.25 133 4.63 118 5.87 149 4.38 111 28.00
DIAGRAMS BELOW DEPICT INSTALLED PRIMARY FUSING OPTION.
DIAGRAMS DEPICT UNITS 500VA AND UP.
11 MICRON POWER DELIVERY
DIMENSIONAL DATA (KVA SIZES)
KVA SIZES CAN EITHER BE SERIES 2 OR IMPERVITRAN DIAGRAMS DEPICT SERIES 2 DESIGN.
NOTE:
SERIES 2 AND IMPERVITRAN
TERMINAL BLOCK CAN HAVE
4 OR 6 TERMINALS AS NOTED.
PRIMARY FUSE BLOCK ADDS
1.375" (35MM) TO "C" DIMENSION.
A D C B E
NOTE: DIMENSION"C"' IS A MAXIMUM DIMENSION. IF SECONDARY FUSE CLIPS ARE
INCLUDED IN DESIGN, DEDUCT A MAXIMUM OF 0.50 (12.7MM) TO REMOVE.
ALWAYS REQUEST CURRENT FACTORY DRAWING FOR FINAL REFERENCE.
DIMENSIONS INCHES/MM
CATALOG (VOLTAGE) GROUP
A B C D E APPROX
A (BTZ13) (MAX) MAXIMUM CENTERS WEIGHT
VA IN MM IN MM IN MM IN MM IN MM LBS
1000 6-TERM 6.11 155 6.75 172 6.30 160 3.91 99 6.13 156 30.50
1500 6-TERM 8.11 206 6.75 172 6.32 161 6.12 155 6.13 156 50.10
2000 6-TERM 7.75 197 6.75 172 6.28 160 4.97 126 6.13 156 46.00
3000 6-TERM 8.06 205 9.00 229 7.50 191 5.25 133 7.50 191 55.90
5000 6-TERM 10.38 264 9.00 229 7.50 191 7.56 192 7.50 191 84.40
G (MBT13)
1000 6-TERM 7.44 189 6.38 162 5.42 138 5.06 129 5.31 135 37.00
1500 6-TERM 8.50 216 6.75 172 5.73 146 6.09 155 6.13 156 53.90
2000 6-TERM 8.13 207 6.75 172 5.75 146 5.25 133 6.13 156 42.00
3000 6-TERM 8.56 217 9.00 229 7.50 191 5.75 146 7.50 191 64.50
5000 6-TERM 10.00 254 9.00 229 7.50 191 7.56 192 7.50 191 97.00
H (BTWZ37)
1000 6-TERM 7.00 178 6.38 162 5.42 138 5.06 129 5.31 135 31.80
1500 6-TERM 7.45 189 6.75 172 6.29 160 5.25 133 6.13 156 44.20
2000 6-TERM 7.56 192 9.00 229 7.80 198 4.81 122 7.50 191 57.70
3000 6-TERM 8.75 222 9.00 229 7.50 191 5.94 151 7.50 191 76.20
5000 6-TERM 11.00 279 9.00 229 7.50 191 8.19 208 7.50 191 127.40
M
240/480 X 120/240
1000 4-TERM 7.00 178 5.25 133 4.25 108 5.38 137 4.38 111 26.30
1500 6-TERM 7.00 178 6.75 172 5.75 146 4.25 108 6.13 156 31.00
2000 6-TERM 7.75 197 6.75 172 5.73 146 4.97 126 6.13 156 46.00
3000 6-TERM 8.06 205 9.00 229 7.50 191 5.25 133 7.50 191 56.00
5000 6-TERM 10.00 254 9.00 229 7.50 191 7.19 183 7.50 191 85.40
N
240,347,380 X 120/240
1000 6-TERM 7.38 187 6.38 162 5.44 138 5.06 129 5.31 135 29.00
1500 6-TERM 8.13 207 6.38 162 5.44 138 5.06 129 5.31 135 33.30
2000 6-TERM 8.88 226 6.75 172 5.75 146 6.13 156 6.13 156 50.00
3000 6-TERM 8.50 216 9.00 229 7.50 191 5.69 146 7.50 191 74.00
5000 6-TERM 10.38 264 9.00 229 7.50 191 7.56 192 7.50 191 110.00
DIAGRAMS DEPICT IMPERVITRAN DESIGN.
12 MICRON POWER DELIVERY
DIMENSIONAL DATA
NOTE:
SERIES 2 AND IMPERVITRAN
TERMINAL BLOCK CAN HAVE
4 OR 6 TERMINALS AS NOTED.
PRIMARY FUSE BLOCK ADDS
1.375" (35MM) TO "C" DIMENSION.
A D C B E
NOTE: DIMENSION"C"' IS A MAXIMUM DIMENSION. IF SECONDARY FUSE CLIPS ARE
INCLUDED IN DESIGN, DEDUCT A MAXIMUM OF 0.50 (12.7MM) TO REMOVE.
ALWAYS REQUEST CURRENT FACTORY DRAWING FOR FINAL REFERENCE.
CATALOG (VOLTAGE) GROUP DIMENSIONS INCHES/MM
OBSOLETE GROUP "J" A B C D E APPROX
ORIGINAL IMPERVITRAN SERIES 2 (MAX) ALL VERSIONS MAXIMUM CENTERS WEIGHT
P/N IN MM IN MM IN MM IN MM IN MM LBS
B050MBT713XK 4-TERM 3.50 89 3.00 76 3.14 79 2.25 57 2.50 64 3.40
B075MBT713XK 4-TERM 3.50 89 3.38 86 3.44 87 2.44 62 2.82 71 4.80
B100MBT713XK 4-TERM 3.63 92 3.75 95 3.78 96 2.44 62 3.13 79 5.90
B150MBT713XKF 4-TERM 4.00 102 3.75 95 3.78 96 3.19 81 3.13 79 8.00
B200MBT713XKF 4-TERM 4.38 111 4.50 114 4.40 112 3.00 76 3.75 95 9.80
B250MBT713XKF 4-TERM 4.38 111 4.50 114 4.40 112 3.75 95 3.75 95 12.00
B300MBT713XKF 4-TERM 5.19 132 5.25 133 5.14 131 3.88 99 4.38 111 14.00
B350MBT713XKF 4-TERM 5.00 127 5.25 133 5.14 131 3.88 99 4.38 111 15.00
B500MBT713XKF 4-TERM 5.50 140 5.25 133 5.14 131 5.38 137 4.38 111 18.00
J
SERIES 2
B050-2000-1 4-TERM 4.53 115 3.00 76 3.14 79 2.82 71 2.50 64 3.40
B075-2001-1 4-TERM 4.53 115 3.75 95 3.78 96 2.82 71 3.13 79 4.80
B100-2002-1 4-TERM 4.53 115 3.75 95 3.78 96 3.00 76 3.13 79 5.90
B150-2003-1F 4-TERM 5.03 128 3.75 95 3.78 96 3.19 81 3.13 79 8.00
B200-2004-1F 4-TERM 4.38 111 4.50 114 4.40 112 3.00 76 3.75 95 9.80
B250-2005-1F 4-TERM 4.75 121 4.50 114 4.40 112 3.75 95 3.75 95 12.00
B300-2006-1F 4-TERM 6.11 155 5.25 133 5.14 131 3.88 99 4.38 111 14.00
B350-2007-1F 6-TERM 6.11 155 5.25 133 5.14 131 3.88 99 4.38 111 15.00
B500-2008-1F 6-TERM 7.11 181 5.25 133 5.14 131 5.38 137 4.38 111 18.00
B750-2009-1F 6-TERM 7.11 181 6.75 172 6.30 160 4.97 126 6.13 156 38.60
B1K0-2010-1F 6-TERM 8.13 207 6.75 172 5.73 146 6.13 156 6.13 156 48.40
L
ORIGINAL IMPERVITRAN
B050-0482-1 6-TERM 3.44 87 3.88 99 3.38 86 2.41 61 2.81 71 4.00
B100-0483-1 6-TERM 4.00 102 3.75 95 3.50 89 3.00 76 3.13 79 6.60
B150-0484-1F 6-TERM 4.00 102 4.50 114 4.50 114 2.82 71 3.75 95 8.70
B250-0485-1F 6-TERM 5.75 146 4.50 114 4.50 114 4.38 111 3.75 95 11.40
B350-0486-1F 6-TERM 5.14 131 5.25 133 4.75 121 4.38 111 4.38 111 13.60
B500-0487-1F 6-TERM 7.19 183 5.14 131 4.75 121 5.88 149 4.38 111 17.40
B750-0488-1F 6-TERM 6.50 165 6.75 172 6.00 152 4.25 108 6.13 156 27.50
DIAGRAMS BELOW DEPICT INSTALLED PRIMARY FUSING OPTION.
DIAGRAMS DEPICT UNITS 500VA AND UP.
13 MICRON POWER DELIVERY
CONNECTION DIAGRAMS
CONNECTION DIAGRAM: CONNECTION DIAGRAM: CONNECTION DIAGRAM:
GROUP "A" GROUP "B" GROUP "C"
CONNECTION DIAGRAM: CONNECTION DIAGRAM: CONNECTION DIAGRAM:
GROUP "E" GROUP "F" GROUP "G"
CONNECTION DIAGRAM: CONNECTION DIAGRAM: CONNECTION DIAGRAM:
GROUP "H" GROUP "I" GROUP "J"
CONNECTION DIAGRAM: CONNECTION DIAGRAM: CONNECTION DIAGRAM:
GROUP "K" GROUP "L" GROUP "M"
CONNECTION DIAGRAM: CONNECTION DIAGRAM:
GROUP "N" GROUP "P"
14 MICRON POWER DELIVERY
CONTROL TRANSFORMER ACCESSORIES
CATALOG
APPROX.
NUMBER WEIGHT
LBS KG
IP-20 SAFETOUCH™ COVERS
TPTC-2001 10PACK 4TERM. 1.0 0.5
TPTC-2002 10PACK 6TERM. 1.0 0.5
TPTC-2006 10PACK UNIVERSAL PRI BLOCK 1.0 0.5
FKTP-1001 PRIMARY CL "CC" FUSE KIT 0.25 0.1
OPTIONAL FACTORY INSTALLED FUSE HOLDERS
CL. "CC" PRI. P/N SUFFIX = RB, RK, RX, RJ, RR N/A
RY, RG, RL, RN, RC, -8
*NON-REJECTION VERSION AVAILABLE
ON ALL FACTORY INSTALLED PRIMARY
FUSEBLOCK OPTIONS
1/4 X 1-1/4 SEC. P/N SUFFIX = JQ, XQ N/A
9/16 X 2 SEC. P/N SUFFIX = JM, XM N/A
BULK FUSE CLIPS
514-1661-01C (2 NECESSARY) 13/32 X 1-1/2 (STD) N/A
514-1661-02C (2 NECESSARY) 1/4 X 1-1/4 (OPT) N/A
BULK JUMPERS
514-1650 J-2 N/A
514-1652 J-3 N/A
514-1620-02 Flat N/A
TRANSFORMER ACCESSORY INTERCHANGE MATRIX
DUAL PRIMARY
STANDARD SUFFIX FUSED SUFFIX
JK, JKF, JKH >> RB, RBF, RBH
XK, XKF, XKH >> RK, RKF, RKH
XX, XXF, XXH >> RX, RXF, RXH
XJ, XJF, XJH >> RJ, RJF, RJH
JJ, JJF, JJH >> RR, RRF, RRH
JM, JMF, JMH >> RY, RYF, RYH
XM, JMF, JMH >> RG, RGF, RGH
JQ, JQF, JQH >> RL RLF, RLH
XQ, XQF, XQH >> RN, RNF, RNH
JX, JXF, JXH >> RC, RCF, RCH
-1, -1F, -1H >> -8, -8F, -8H
15 MICRON POWER DELIVERY
PRIMARY FUSE KIT # FKTP-1001 IP-20 COVER KIT # TPTC-2006
SERIES 2 INSTRUCTIONS ON NEXT PAGE
4. Remove two nuts or screws holding primary fuse block to
transformer. On FKTP-1001 kits, perform step #5 prior to
affixing block to brackets.
5. Install retaining clips in base of fuse block. Secure with nuts
or screws as appropriate.
In addition to factory installed primary fusing capability
6, 6a. Install fuse in cover and snap cover in place. When installed
Micron offers a primary fuse kit for ImperviTRAN and cover cannot be removed without releasing tab from detent (6a).
ValuTRAN intended for field installation. The A tip of a pen will suffice.
primary fuse kit includes a 2-pole Class "CC" fuse
block, instructions and all associated mounting GLOBALTRAN ACCESSORIES
hardware. Addititonally, this fuse block will fit most
competitive units. To order this kit, use catalog number A number of fusing accessories are available for the
FKTP-1001. The primary fuse kit, when installed, will
GlobalTRAN product line. Please contact Micron
add a maximum of 11/16" to the transformer "A" with your design requirements.
dimension and 1-15/16" to the "C" dimension.
Installed as indicated.
1. Loosen two outer screws on primary side of
transformer. On 6 position shell leave 2 spaces
open between brackets.
2. Capture mounting brackets and necessary leads
under terminal screws and tighten.
Recommended torque 30 in-lbs.
3. Affix fuse block to mounting bracket with
supplied screws.
16 MICRON POWER DELIVERY
PRIMARY FUSE KIT # FKTP-1001 SERIES 2 INSTRUCTIONS
In addition to factory installed primary fusing capability
Micron offers a primary fuse kit for units with integral
accessory mounting plate (#2) intended for field installation
on all catalog standard SERIES 2 units.
The primary fuse kit includes a 2-pole Class "CC" fuse
block, instructions and all associated mounting
hardware. To order this kit, use catalog number
FKTP-1001. The primary fuse kit, when installed, will
add a maximum of 1-3/8" to the "C" dimension.
(as measured from the top of the plate)
Installation instructions.
1. Connect one end of the 2 primary leads (#1) under the
appropriate primary terminal screws. Secure screws
to 16 in-lbs <500VA and 30 in-lbs 500VA and larger.
2. Insert locking clips (#4) oriented as shown into the fuse
block (#3) pockets. Use caution in choosing screw length
if locking clips are not used.
3. Attach clips and fuse block to accessory mounting plate
(#2) using screws (#5). Recommended torque 16 in-lbs.
4. Insert fuses (not supplied) into fuse block followed by fuse
fuse block covers (#6) (IF ORDERED) with lock slots (#6a)
matching tip of the clips, as shown. Press down until cover locks.
Refer to primary fuse chart for recommended fuses.
Cover cannot be removed without releasing tab from
detent (#6a). A tip of a pen will suffice.
5. Connect trhe other end of the 2 primary leads (#1) under the
screws on each of the 2 poles on the fuse block (#3a) and
secure to 20 inch-pounds.
6. Apply primary voltage to the opposite end of the fuse block
(#3b).
Additionally the mounting plate (#2) can be utilized to mount other
accessories such as DIN rail. Use caution in choosing screw length.
17 MICRON POWER DELIVERY
MICRON STANDARD FUSE DIMENSION IS 13/32 X 1-1/2 "MIDGET" FUSE
MAXIMUM ACCEPTABLE RATING OF SECONDARY OVERCURRENT PROTECTION
Secondary VA Rating
Voltage 25 50 75 100 150 200 250 300 350 500 750
23 1-8/10 3-1/2 5 7 10 12 15 20 20 30 45
24 1-6/10 3-2/10 5 6-1/4 10 12 15 20 20 30 40
25 1-6/10 3-2/10 5 6-1/4 10 12 15 15 20 25 40
90 4/10 8/10 1-1/4 1-8/10 2-1/2 3-1/2 4-1/2 5 6-1/4 9 12
95 4/10 8/10 1-1/4 1-6/10 2-1/2 3-1/2 4 5 6 8 12
100 4/10 8/10 1-1/4 1-6/10 2-1/2 3-2/10 4 5 5-6/10 8 12
110 3/10 3/4 1-1/8 1-1/2 2-1/4 3 3-1/2 4-1/2 5 7-1/2 10
115 3/10 6/10 1 1-4/10 2 2-8/10 3-1/2 4 5 7 10
120 3/10 6/10 1 1-1/4 2 2-1/2 3-2/10 4 4-1/2 6-1/4 10
220 15/100 3/10 1/2 3/4 1-1/8 1-1/2 1-8/10 2-1/4 2-1/2 3-1/2 5-6/10
230 15/100 3/10 1/2 6/10 1 1-1/4 1-6/10 2 2-1/4 3-2/10 5
1-4/10 1-8/10 2-1/2 3-1/2
240 3/10 1/2 6/10 1 1-1/4 1-6/10 2 2-1/4 3-2/10 5
SECONDARY CURRENT = TRANSFORMER VA ÷ SECONDARY VOLTS
If the rated secondary current is less than 9 amps, the maximum rating of the overcurrent device is 167%; 9 amps or more, the maximum
rating of the overcurrent device is 125%. If 125% does not correspond to a standard fuse rating, the next highest standard rating may be
used.
Reference: NEC 430-72(c) exception #2; 450-3(b) 1 & 2; UL 508, 32.7; UL 845, 11.16 & 11.17.
18 MICRON POWER DELIVERY
Features and Benefits
Lead -free solder joints
Encapsulated from 25Va through 5KVa
 Provides RoHS compliant construction  Establishes product similarity throughout the product range
Fully encapsulated coil
Full nameplate VA rating
 Tough environment-proof construction  Eliminates guesswork
 Eases wire routing around the transformer
Molded terminals as an integral part of the coil
Largest standard voltage selection in the industry
 Easily adaptable to slot and Phillips driver tools  Solves “availability problem” for many OEM design-in opportunities
 Robust physical support instead of “floating” terminal strips
 Both 4 and 6 terminals, or the combination, available
IP-20 level covers installed
UL/CSA/cUL/CE Family Listing
 Meets IEC-529 protection rating  Absolute flexibility of special design capability for 600 volt class product
GlobalTRAN
products carry the CE mark, certifying 100%
compliance with requirements of EN61558. Additionally all
GlobalTRAN products are designed to deliver the full nameplate VA
rating.
GLOBALTRAN
CE CONTROL TRANSFORMERS
GENERAL SPECIFICATIONS:
STYLE: IMPERVITRAN
APPROVALS: UL LISTED FILE# E46323/ CSA APPROVED FILE# LR27533, EN 61558-2-2
TEMP CLASS: 105°C/130°C/180°C
VA SIZES: 50-5000
SUFFIX DESCRIPTION:
TWO LETTER SUFFIX = TEMP CLASS 105C
THREE LETTER SUFFIX ENDING "F" = TEMP CLASS 130C
THREE LETTER SUFFIX ENDING "H" = TEMP CLASS 180C
GLOBALTRAN: GLOBALTRAN:
GROUP "A" GROUP "D"
CATALOG CATALOG
NUMBER NUMBER
VOLTAGE: VOLTAGE:
PRI: 220x440, 230x460, 240x480 PRI: 550/575/600
SEC: 110/115/120 SEC: 110/115/120
VA AMPS VA AMPS
B050-2001-GA 50 0.43 B050-2041-GA 50 0.43
B075-2002-GA 75 0.65 B075-2042-GA 75 0.65
B100-2003-GA 100 0.87 B100-2043-GA 100 0.87
B150-2004-GAF 150 1.30 B150-2044-GAF 150 1.30
B200-2005-GAF 200 1.74 B200-2045-GAF 200 1.74
B250-2006-GAF 250 2.17 B250-2046-GAF 250 2.17
B300-2007-GAF 300 2.61 B300-2047-GAF 300 2.61
B350-2008-GAF 350 3.04 B350-2048-GAF 350 3.04
B500-2009-GAF 500 4.35 B500-2049-GAF 500 4.35
B750-2010-GAF 750 6.52 B750-2050-GAF 750 6.52
B1K0-2008-GAH 1000 8.70
B1K5-2009-GAH 1500 13.04
B2K0-2010-GAH 2000 17.39
B3K0-2011-GAH 3000 26.09
B5K0-2012-GAH 5000 45.45
GROUP "B" GROUP "E"
VOLTAGE: VOLTAGE:
PRI: 240x480 PRI: 380/400/415
SEC: 24 SEC: 110x220
VA AMPS VA AMPS
B050-2011-GA 50 2.08 B050-2061-GA 50 .46/.23
B075-2012-GA 75 3.13 B075-2062-GA 75 .68/.34
B100-2013-GA 100 4.17 B100-2063-GA 100 .91/.46
B150-2014-GAF 150 6.25 B150-2064-GAF 150 1.37/.69
B200-2015-GAF 200 8.33 B200-2065-GAF 200 1.82/.91
B250-2016-GAF 250 10.42 B250-2066-GAF 250 2.28/1.14
B300-2017-GAF 300 12.50 B300-2067-GAF 300 2.72/1.36
B350-2018-GAF 350 14.58 B350-2068-GAF 350 3.18/1.59
B500-2019-GAF 500 20.83 B500-2069-GAF 500 4.55/2.27
B750-2020-GAF 750 31.25 B750-2070-GAF 750 6.82/3.41
B1K0-2028-GAF 1000 41.67
GROUP "C" GROUP "F"
VOLTAGE: VOLTAGE:
PRI: 120x240 PRI: 208/230/460
SEC: 24 SEC: 24/115
VA AMPS VA AMPS
B050-2021-GA 50 2.08 B050-2101-GA 50 2.08/.44
B075-2022-GA 75 3.13 B075-2102-GA 75 3.13/.65
B100-2023-GA 100 4.17 B100-2103-GA 100 4.17/.87
B150-2024-GAF 150 6.25 B150-2104-GAF 150 6.25/1.3
B200-2025-GAF 200 8.33 B200-2105-GAF 200 8.33/1.74
B250-2026-GAF 250 10.42 B250-2106-GAF 250 10.42/2.17
B300-2027-GAF 300 12.50 B300-2107-GAF 300 12.50/2.61
B350-2028-GAF 350 14.58 B350-2108-GAF 350 14.58/3.04
B500-2029-GAF 500 20.83 B500-2109-GAF 500 20.83/4.35
B750-2030-GAF 750 31.25 B750-2110-GAF 750 31.25/6.52
B1K0-2048-GAF 1000 41.67 B1K0-2188-GAH 1000 41.67/8.70
20 MICRON POWER DELIVERY
CE CONTROL TRANSFORMERS
GLOBALTRAN: GLOBALTRAN:
GROUP "G" GROUP "I"
CATALOG CATALOG
NUMBER NUMBER
VOLTAGE: VOLTAGE:
PRI: 380 PRI: 208/230/400/460/575
SEC: 24 SEC: 24*/115/230
VA AMPS VA AMPS
B050-2051-GA 50 2.08 B250-2263-GAF 250 10.4/2.2/1.1
B075-2052-GA 75 3.13 B300-2264-GAF 300 12.5/2.6/1.3
B100-2053-GA 100 4.17 B350-2265-GAF 350 14.6/3.0/1.5
B150-2054-GAF 150 6.25 B500-2266-GAF 500 20.8/4.3/2.2
B200-2055-GAF 200 8.33 B750-2267-GAF 750 31.3/6.5/3.3
B250-2056-GAF 250 10.42 B1K0-2268-GAH 1000 41.7/8.7/4.3
B300-2057-GAF 300 12.50 B1K5-2269-GAH 1500 13.04/6.52
B350-2058-GAF 350 14.58 B2K0-2270-GAH 2000 17.39/8.70
B500-2059-GAF 500 20.83 B3K0-2271-GAH 3000 26.09/13.04
B750-2060-GAF 750 31.25 B5K0-2272-GAH 5000 43.48/21.74
* 24 AVAILABLE THROUGH 1Kva
GROUP "H" GROUP "J"
VOLTAGE: VOLTAGE:
PRI: 208-600 PRI: 230/400/460/575
SEC: 85-130 SEC: 24/115
VA AMPS VA AMPS
B250-2283-GAF 250 1.92 B250-2243-GAF 250 10.4/2.2
B300-2284-GAF 300 2.31 B300-2244-GAF 300 12.5/2.6
B350-2285-GAF 350 2.69 B350-2245-GAF 350 14.6/3.0
B500-2286-GAF 500 3.85 B500-2246-GAF 500 20.8/4.3
B750-2287-GAF 750 5.77 B750-2247-GAF 750 31.3/6.5
B1K0-2288-GAH 1000 7.69 B1K0-2248-GAH 1000 41.7/8.7
B1K5-2289-GAH 1500 11.54
B2K0-2290-GAH 2000 15.38
B3K0-2291-GAH 3000 23.08
21 MICRON POWER DELIVERY
4 TERMINAL
6 TERMINAL
A D C B E
CATALOG GROUPS DIMENSIONS INCHES (MM) APPROX
P/N A B C
D
E
WEIGHT
A IN MM IN MM IN MM IN MM IN MM LBS
B050-2001-GA 3.38 86 3.00 76 3.00 76 2.44 61 2.50 64 3.4
B075-2002-GA 3.38 86 3.38 86 3.25 83 2.44 61 2.81 71 4.8
B100-2003-GA 3.38 86 3.75 95 3.50 89 2.44 61 3.13 79 5.9
B150-2004-GAF 3.75 95 4.50 114 4.00 102 2.44 61 3.75 95 8.5
B200-2005-GAF 3.75 95 4.50 114 4.00 102 2.81 71 3.75 95 10.0
B250-2006-GAF 4.00 102 4.50 114 4.00 102 3.19 81 3.75 95 11.0
B300-2007-GAF 4.38 111 4.50 114 4.00 102 3.75 95 3.75 95 13.0
B350-2008-GAF 4.88 124 5.25 133 4.50 114 3.38 86 4.38 111 15.0
B500-2009-GAF 5.13 130 5.25 133 4.50 114 4.38 111 4.38 111 20.0
B750-2010-GAF 7.00 178 5.25 133 4.50 114 5.88 149 4.38 111 29.8
B1K0-2008-GAH 6.63 168 6.38 162 5.50 140 3.75 95 5.31 135 35.0
B1K5-2009-GAH 7.31 186 6.75 172 6.00 152 5.00 127 6.13 156 40.0
B2K0-2010-GAH 8.13 203 6.75 172 6.00 152 5.25 133 6.13 156 45.0
B3K0-2011-GAH 8.06 202 9.00 225 8.00 200 5.25 133 7.50 191 65.2
B5K0-2012-GAH 10.00 250 9.00 225 8.00 200 7.19 183 7.50 191 104.8
B
B050-2011-GA 3.38 86 3.00 76 3.00 76 2.19 56 2.50 64 3.4
B075-2012-GA 3.38 86 3.38 86 3.25 83 2.19 56 2.81 71 4.2
B100-2013-GA 3.38 86 3.75 95 3.50 89 2.44 61 3.13 80 5.9
B150-2014-GAF 4.00 102 4.50 114 4.00 102 2.44 62 3.75 95 8.5
B200-2015-GAF 3.75 95 4.50 114 4.00 102 2.81 71 3.75 95 10.0
B250-2016-GAF 4.00 102 4.50 114 4.00 102 3.19 81 3.75 95 11.0
B300-2017-GAF 4.38 111 4.50 114 4.00 102 3.75 95 3.75 95 13.2
B350-2018-GAF 4.50 114 5.25 133 4.50 114 3.38 86 4.38 111 14.9
B500-2019-GAF 5.13 130 5.25 133 4.50 114 3.88 99 4.38 111 19.2
B750-2020-GAF 7.00 178 5.25 133 5.00 127 5.38 137 4.38 111 28.1
B1K0-2028-GAF 7.00 178 6.38 162 6.00 152 3.75 95 5.31 135 30.0
C
B050-2021-GA 3.38 86 3.00 76 3.00 76 2.19 55 2.50 64 3.4
B075-2022-GA 3.38 86 3.38 86 3.25 83 2.19 56 2.81 71 4.2
B100-2023-GA 3.38 86 3.75 95 3.50 89 2.44 61 3.13 79 5.9
B150-2024-GAF 3.75 95 4.50 114 4.00 102 2.44 61 3.75 95 8.5
B200-2025-GAF 3.75 95 4.50 114 4.00 102 2.81 70 3.75 95 10.0
B250-2026-GAF 4.00 102 4.50 114 4.00 102 3.19 81 3.75 95 11.0
B300-2027-GAF 4.38 111 4.50 114 4.00 102 3.75 95 3.75 95 13.2
B350-2028-GAF 4.50 114 5.25 133 4.50 114 3.38 86 4.38 111 14.9
B500-2029-GAF 5.13 130 5.25 133 4.50 114 3.88 99 4.38 111 19.2
B750-2030-GAF 7.00 178 5.25 133 4.50 114 5.88 149 4.38 111 29.8
B1K0-2048-GAF 7.00 178 6.38 162 6.00 152 3.75 95 5.31 135 31.0
D
B050-2041-GA 3.38 86 3.00 76 3.00 76 2.44 61 2.50 64 3.4
B075-2042-GA 3.38 86 3.38 86 3.25 83 2.44 61 2.81 71 4.8
B100-2043-GA 3.38 86 3.75 95 3.50 89 2.44 61 3.13 80 5.9
B150-2044-GAF 3.75 95 4.50 114 4.00 102 2.44 61 3.75 95 8.5
B200-2045-GAF 3.75 95 4.50 114 4.00 102 3.00 76 3.75 95 10.0
B250-2046-GAF 4.00 102 4.50 114 4.00 102 3.19 81 3.75 95 11.0
B300-2047-GAF 4.38 111 4.50 114 4.00 102 3.75 95 3.75 95 13.0
B350-2048-GAF 4.50 114 5.25 133 4.50 114 3.38 86 4.38 111 15.0
B500-2049-GAF 5.13 130 5.25 133 4.50 114 4.38 111 4.38 111 20.0
B750-2050-GAF 7.00 178 5.25 133 4.50 114 5.38 137 4.38 111 28.0
22 MICRON POWER DELIVERY
4 TERMINAL
6 TERMINAL
A D C B E
CATALOG GROUPS DIMENSIONS INCHES (MM) APPROX
P/N A B C
D
E
WEIGHT
E IN MM IN MM IN MM IN MM IN MM LBS
B050-2061-GA 3.38 86 3.00 76 3.00 76 2.44 61 2.50 64 3.4
B075-2062-GA 3.38 86 3.38 86 3.50 89 2.44 61 2.81 71 4.8
B100-2063-GA 3.38 86 3.75 95 3.50 89 2.44 61 3.13 79 5.9
B150-2064-GAF 3.75 95 4.50 114 4.00 102 2.44 61 3.75 95 8.5
B200-2065-GAF 3.75 95 4.50 114 4.00 102 3.00 76 3.75 95 10.0
B250-2066-GAF 4.00 102 4.50 114 4.00 102 3.19 81 3.75 95 11.0
B300-2067-GAF 4.38 111 4.50 114 4.00 102 3.75 95 3.75 95 13.0
B350-2068-GAF 4.75 121 4.50 114 4.00 102 3.75 95 3.75 95 15.0
B500-2069-GAF 5.13 130 5.25 133 4.50 114 4.38 111 4.38 111 20.0
B750-2070-GAF 7.00 178 5.25 133 4.50 114 5.88 149 4.38 111 27.0
F
B050-2101-GA 3.38 86 3.00 76 3.25 83 2.25 56 2.81 71 4.2
B075-2102-GA 3.38 86 3.38 86 3.50 89 2.44 61 3.13 79 5.9
B100-2103-GA 3.63 92 3.75 95 3.50 89 3.19 81 3.13 79 7.9
B150-2104-GAF 3.75 95 4.50 114 4.00 102 2.81 71 3.75 95 10.0
B200-2105-GAF 4.38 111 4.50 114 4.00 102 3.44 87 3.75 95 12.8
B250-2106-GAF 4.75 121 4.50 114 4.00 102 3.75 95 3.75 95 14.0
B300-2107-GAF 4.88 124 5.25 133 4.50 114 3.88 99 4.38 111 16.8
B350-2108-GAF 4.88 124 5.25 133 4.50 114 3.88 99 4.38 111 19.2
B500-2109-GAF 5.63 143 5.25 133 4.50 114 5.88 149 4.38 111 29
B750-2110-GAF 6.63 168 6.38 162 6.00 152 5.06 129 5.31 111 29.8
B1K0-2188-GAH 7.06 179 6.38 162 6.00 152 5.06 129 5.31 135 30.2
G
B050-2051-GA 3.38 86 3.00 76 3.00 76 2.19 55 2.50 64 3.5
B075-2052-GA 3.38 86 3.38 86 3.25 83 2.19 56 2.81 71 4.2
B100-2053-GA 3.38 86 3.75 95 3.50 89 2.44 61 3.13 79 5.9
B150-2054-GAF 3.63 91 3.75 95 3.50 89 3.00 61 3.13 79
B200-2055-GAF 3.75 95 4.50 114 4.00 102 2.81 70 3.75 95 9.6
B250-2056-GAF 4.00 102 4.50 114 4.00 102 3.19 81 3.75 95 11.3
B300-2057-GAF 4.38 111 4.50 114 4.00 102 3.75 95 3.75 95 13.2
B350-2058-GAF 4.50 114 5.25 133 4.50 114 3.88 99 4.38 111 14.9
B500-2059-GAF 5.13 130 5.25 133 4.50 114 3.88 99 4.38 111 19.2
B750-2060-GAF 7.00 178 5.25 133 4.50 114 5.88 149 4.38 111 29.8
H
B250-2283-GAF 4.25 108 4.50 114 4.00 102 3.44 86 3.75 95 11.4
B300-2284-GAF 4.75 121 4.50 114 4.00 102 3.75 95 3.75 95 13.6
B350-2285-GAF 5.00 127 4.50 114 4.00 102 3.75 95 3.75 95 14.2
B500-2286-GAF 5.50 140 5.25 133 4.25 108 3.88 99 4.38 111 17.4
B750-2287-GAF 7.38 187 5.25 133 4.50 114 5.88 149 4.38 111 27.5
B1K0-2288-GAH 7.00 178 6.38 162 5.50 140 5.06 129 5.31 135 27.9
B1K5-2289-GAH 7.75 199 6.75 171 6.00 152 5.00 127 6.13 156 43.1
B2K0-2290-GAH 7.63 194 9.00 229 8.00 203 4.81 122 7.50 191 56.0
B3K0-2291-GAH 8.56 217 9.00 229 7.63 194 5.75 146 7.50 191 76.2
23 MICRON POWER DELIVERY
4 TERMINAL
6 TERMINAL
A D C B E
CATALOG GROUPS DIMENSIONS INCHES (MM) APPROX
P/N A B C
D
E
WEIGHT
I IN MM IN MM IN MM IN MM IN MM LBS
B250-2263-GAF 4.75 121 4.50 114 4.00 102 4.75 121 3.75 95 14.9
B300-2264-GAF 5.25 133 4.50 114 4.00 102 4.75 121 3.75 95 17.4
B350-2265-GAF 5.38 137 5.25 133 4.50 114 4.38 111 4.38 111 17.8
B500-2266-GAF 5.63 168 5.25 133 4.50 114 5.88 149 4.38 111 26.6
B750-2267-GAF 7.44 189 6.38 162 6.00 152 5.06 129 5.31 135 32.5
B1K0-2268-GAH 7.75 199 6.75 171 6.25 159 5.00 127 6.13 156 44.0
B1K5-2269-GAH 7.75 199 6.75 171 6.00 152 5.00 127 6.13 156 45.4
B2K0-2270-GAH 7.63 194 9.00 229 7.63 194 4.81 122 7.50 191 58.6
B3K0-2271-GAH 8.75 222 9.00 229 7.63 194 5.94 151 7.50 191 92.9
B5K0-2272-GAH 10.44 265 9.00 229 7.63 194 7.63 194 7.50 191 127.4
J
B250-2243-GAF 4.75 121 4.50 114 4.00 102 3.75 95 3.75 95 14.3
B300-2244-GAF 5.00 127 4.50 114 4.00 102 4.75 121 3.75 95 15.8
B350-2245-GAF 5.13 130 5.25 133 4.50 114 3.88 99 4.38 111 16.5
B500-2246-GAF 5.75 146 5.25 133 4.50 114 4.88 124 4.38 111 20.5
B750-2247-GAF 7.00 178 6.38 162 6.00 152 5.06 129 5.31 135 28.8
B1K0-2248-GAH 8.13 207 6.38 162 6.00 152 5.06 129 5.31 135 34.9
24 MICRON POWER DELIVERY
CONNECTION DIAGRAMS - GLOBALTRAN
CONNECTION DIAGRAM:
CONNECTION DIAGRAM:
CONNECTION DIAGRAM:
GROUP "A" GROUP "B" GROUP "C"
CONNECTION DIAGRAM:
CONNECTION DIAGRAM:
CONNECTION DIAGRAM:
GROUP "D" GROUP "E" GROUP "F"
CONNECTION DIAGRAM:
CONNECTION DIAGRAM:
GROUP "G" GROUP "H"
CONNECTION DIAGRAM:
CONNECTION DIAGRAM:
CONNECTION DIAGRAM:
GROUP "I" GROUP "I" GROUP "J"
Above 1 Kva Through 1 Kva
25 MICRON POWER DELIVERY
MEDIUM VOLTAGE CONTROL TRANSFORMERS
Micron medium voltage control transformers have:
* 130° C Insulation system.
* 24" Mimimum primary lead length.
* 60Hz.
* HIPOT - 7,400 volts for 2400 primary.
* HIPOT - 11,500 volts for 4160 and 2400 primaries.
* 750 VA - Epoxy impregnated coils.
* 1 KVA and larger - Epoxy potted primary coils.
DIMENSIONS
CONTROL TRANSFORMERS:
MEDIUM VOLTAGE
CATALOG OUTPUT DIMENSIONS INCHES (MM) APPROX.
NUMBER VA AMPS A B C
D
E
WEIGHT
VOLTAGE: IN MM IN MM IN MM IN MM IN MM LBS
*PRI: 4200
PRI: 2400
SEC: 120
H750-0030 * 750 6.25 6.63 168 6.38 162 5.81 148 5.25 133 5.31 135 30.5
H750-0031 750 6.25 6.63 168 6.38 162 5.81 148 5.25 133 5.31 135 30.7
*PRI: 4160
PRI: 2400
SEC: 120/240
H1K0-0010 1000 8.33/4.17 6.25 159 7.56 192 6.38 162 3.50 89 5.63 143 31.3
H1K0-0015 * 1000 8.33/4.17 6.25 159 7.56 192 6.38 162 3.50 89 5.63 143 31.1
HN1K5F1519P 1500 12.50/6.25 7.00 178 9.00 229 7.63 194 4.25 108 6.50 165 53.7
HN1K5G1519P * 1500 12.50/6.25 7.00 178 9.00 229 7.63 194 4.25 108 6.50 165 52.2
HN2K0F1519P 2000 16.67/8.33 7.94 202 9.00 229 7.63 194 5.19 132 6.50 165 65.4
HN2K0G1519P * 2000 16.67/8.33 7.94 202 9.00 229 7.63 194 5.19 132 6.50 165 58.2
HN3K0F1519P 3000 25.00/12.50 9.75 248 9.00 229 7.63 194 7.00 178 6.50 165 99.9
HN3K0G1519P * 3000 25.00/12.50 9.75 248 9.00 229 7.63 194 7.00 178 6.50 165 101.0
26 MICRON POWER DELIVERY
DINergy Industrial DIN Rail Power Supplies
Micron DINergy™ Power Supply Selection Guide
Model
Output
Power
(Watts)
Output
Voltage
(VDC)
Voltage
Adj.
Range
Output
Current
(A)
Peak
Current (A)
Input
Voltage
(VAC)
Size
WxDxH(mm)
MDP30-24-1 30 24 22 - 28 1.25 1.70 90-255 22.5X100X90
MDP30-15-1 30 15 14 - 18 2.0 2.70 90-255 22.5X100X90
MDP30-12-1 30 12 10 - 14 2.5 3.40 90-255 22.5X100X90
MDP30-5-1 30 5 4.5 - 5.5 4.0 5.40 90-255 22.5X100X90
MDP50-24-1 50 24 22 - 28 2.27 - 1.79 3.09 90-255 32X102X90
MDP50-12-1 50 12 10 - 14 5.0 - 3.57 6.80 90-255 32X102X90
MD60-24-1 60 24 22 - 28 2.5 3.0 85-264 50x105x124
MD60-12-1 54 12 10 - 16 4.5 5.4 85-264 50x105x124
MD60-48-1 60 48 46 - 52 1.3 1.5 85-264 50x105x124
MD120-24-1 120 24 22 - 28 5.0 6.0 85-264 65x105x124
MD120-12-1 96 12 10 - 16 8.0 9.6 85-264 65x105x124
MD120-48-1 120 48 46 - 52 2.5 3.0 85-264 65x105x124
MD240-24-1 240 24 22 - 28 10.0 12.0 85-264 87x124x130
MD240-12-1 180 12 11 - 14 15.0 18.0 85-264 87x124x130
MD240-48-1 240 48 46 - 52 5.0 6.0 85-264 87x124x130
MD480-24-1 480 24 22 - 28 20.0 24.0 85-264 156x126x130
MD480-36-1 480 36 34 - 40 13.0 16.0 85-264 156x126x130
MD480-24-1 480 48 46 - 52 10.0 12.0 85-264 156x126x130
MD-PDMA 480 24 N/A 20.0 MAX 24.0 MAX 85-264 50x105x124
REDUNDANCY DIODE MODULE
MD-VSB240-24-1 240 24 N/A 10.0 N/A 24VDC 76X116X130
VOLTAGE SAG BUFFER +/-10% +/-5%
MD-LAB-DINBRKTA
N/A 24 N/A
3.4AH/20HR
N/A N/A 145X77X143
MD-LAB-DINBRKTB
N/A 24 N/A
1.3AH/20HR
N/A N/A 95X81X105
MD-DINBRKTA BRACKET ASSEMBLY FOR 3.4AH SLA 145X77X143
MD-DINBRKTB BRACKET ASSEMBLY FOR 1.3AH SLA 95X81X105
27 MICRON POWER DELIVERY
PMA, PCMA, PMAS, PCMAS, PMN & PCMN encapsulated designs feature reduced stand-by power consumption and are
available in various power ranges from 5 watts 100 watts. The primary voltage range of 90 -264 Vac / 100 -353 Vdc with
available single, dual or triple output voltages makes these the logical choice for PCB and chassis mount applications in otherwise
hostile environments.
The PCMASC power supply has been specifically designed to operate at -55ºC and is available at a power rating of 100 watts @
24Vdc.
PMmed / PCMmed encapsulated designs for medical applications are available in power ranges of from 15 watts 100 watts.
The primary voltage range of 90 -264 Vac / 100 -353 Vdc with single output selections for PCB and chassis mount applications
where EN/UL 60 601-1/EN/UL 60 950-1 (2nd Edition) is necessary.
Protected from vibration and the environment, the HMA, HMG, HMN, encapsulated DIN-Mount designs are available in power
ranges of 15 and 30 watts with single, dual or triple output voltages. The HSA design is available through 120 watts with choices
of multiple outputs through 48Vdc. The HSAC variant is certified to operate at -55ºC as well.
The HSD product is a DC/DC DIN-Mount device in power ratings of 15 and 30 watts.
28 MICRON POWER DELIVERY
…MTM Power DC/DC converters for vehicles and
industrial applications…
For rugged vehicular or industrial applications, MTM Power DC/DC converters are available as a standard with
single dual or triple outputs in various power ranges and if required as customized devices. Featuring isolation up to
4 kVac and available in metal or plastic case.
PMG/PCMG encapsulated DC/DC designs are available in power ratings of 15 and 30 watts and with up to three output
voltages.
PMD/PCMD encapsulated DC/DC designs through 400 watts or the PCMDS (space saving) through 650 watts for
vehicular applications.
PMD encapsulated DC/DC designs for industrial applications with power ratings from 1 watt – 350 watts.
MPK1, MPK2 plug-ins for 19” racks and other custom configurations utilize PMA, PMAS, PMN and PMG units and
allow for up to six different, galvanically isolated outputs to 100 watts. PMA19 35 is a19” narrow profile 35 watt unit
available in 5, 12, 24 and 48 Vdc output voltage.
29 MICRON POWER DELIVERY
DRY TYPE TRANSFORMERS
GENERAL INFORMATION
Micron can provide a general purpose or buck-boost transformer to satisfy your industrial or commercial
application. Please refer to Catalog number LVGP-09A for further information
30 MICRON POWER DELIVERY
NOTES:
31 MICRON POWER DELIVERY
Micron Industries Corporation
Oak Brook, IL 60523
Phone: 800-664-4660
FAX: 630-516-1820
www.micronpower.com