17-1
17 NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
© 2012 Schneider Electric
All Rights Reserved
Table of Contents
Section 17
NEMA Contactors and Starters
Electromechanical
Reduced Voltage Starter (p. 17-18)
IEC Style Disconnect Switches
GS1 Fusible and LK3 Nonfusible, UL98 Tested 17-2
GS1 Fusible and LK3 Nonfusible, Dimensions 17-5
UL508 Motor Disconnect Switches
Mini-Vario and Vario™ Switches 17-8
NEMA Style Disconnect Switches
NEMA Style Door-Mounted Disconnect Switches 17-9
Door-Mounted Operating Mechanisms
For Square D™ Circuit Breakers 17-10
Approximate Dimensions 17-12
Bracket-Mounted Disconnect Devices
Type T Disconnect Switches 17-13
Flexible Cable Mechanisms
For Circuit Breakers 17-14
Disconnect Switch Accessories
Flange Mounted, Variable Depth 17-15
Reversing Drum Switches
Type A and B 17-17
Electromechanical Reduced Voltage Starters
Description of All Types 17-18
How to Order 17-18
Autotransformer Starters 17-19
Wye-Delta Starters (Open Transition) 17-20
Wye-Delta Starters (Closed Transition) 17-21
Part Winding Starters 17-22
Approximate Dimensions 17-23
Multispeed Magnetic Starters
Application Data 17-24
Two-Speed Combination Starters 17-26
Reversing Two-Speed Magnetic Starters 17-27
Two-Speed Magnetic Starters 17-28
Approximate Dimensions 17-29
Lighting Contactors
Panelboard Lighting Contactors, Type PB 17-30
Well-Guard™ Pump Panel
Reduced Voltage Type 17-31
Factory Modifications (Forms)
Reduced Voltage Starters 17-32
Definite Purpose Contactors
Reversing/Hoist, Type R 17-35
Thermal Overload Relays—NEMA Style
Solid-State Overload Relay, Motor Logic™ Plus 17-36
www.schneider-electric.us
17-2 © 2012 Schneider Electric
All Rights Reserved
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
IEC Style Disconnect
Switches
GS1 Fusible and LK3 Nonfusible, UL98 Tested
Class 9421 / Refer to Catalog 9421CT0301
The GS1 part numbers can be identified as follows.
See Catalog 9421CT0301 for specific applications.
aShipped with line side terminal shrouds; for additional shrouds,
see page 17-4.
bTerminal lug must be ordered separately—see page 17-4.
Table 17.1: Identification System
GS1 D U 3
Model GS1 Fusible (Class J fuse unless noted), LK3 Nonfusible
Current Range, Operator Type (front operator unless noted), Accessory Type
D30 A front and side operation T800 A (Class L if fused)
DD 30 A Class CC front and side operation U1000 A
E30 A W1200 A
EE 30 A Class CC AH handle
G60 A AHT handle with test
J100 A AE extension shaft
M200 A AD auxiliary contact holder
Q400 A AM auxiliary contact
S600 A
UL Certification
Poles—Number of Poles, 2 or 3
Note: All fusible switches through 400 A and nonfused switches through 200 A are equipped with a feature to test optional auxiliary contacts without energizing
the load when the appropriate GS1AHT•••• handle is used.
Table 17.2: Fusible Switches
Catalog No. Description $ Price
Compact GS1 Fusible IEC Style Disconnect Switches
GS1DDU3 30 A, 3-pole, Class CC, use 5x5 shaft 237.00
GS1DU3 30 A, 3-pole, Class J, use 5x5 shaft 260.00
GS1 Fusible IEC Style Disconnect Switches
GS1EEU3 30 A, 3-pole, Class CC , use 10x10 shaft 237.00
GS1EU3 30 A, 3-pole, Class J, use 10x10 shaft 260.00
GS1GU3 60 A, 3-pole, Class J, use 10x10 shaft 336.00
GS1JU3ab 100 A, 3-pole, Class J, use 10x10 shaft 536.00
GS1MU3ab 200 A, 3-pole, Class J, use 10x10 shaft 1181.00
GS1QU3ab 400 A, 3-pole, Class J, use 10x10 shaft 2252.00
GS1SU3ab 600 A, 3-pole, Class J, use 15x15 shaft 3377.00
GS1TU3ab 800 A, 3-pole, Class L, use 15x15 shaft 5061.00
Table 17.3: Fusible Switches with
Direct Mount Side Handle
Catalog No. Description $ Price
GS1EERU20 30 A, 2-pole, Class CC 204.00
GS1EERU30 30 A, 3-pole, Class CC 242.00
GS1AH01 Right side handle for GS1EERU20 & GS1EERU30 46.40
200 A Switch
GS1MU3
30 A Side Handle
GS1EERU30
Table 17.4: Nonfusible Switches
Catalog No. Description $ Price
Compact LK3 Nonfusible IEC Style Disconnect Switches
LK3DU3 30 A, 3-pole, 5x5 shaft 218.00
LK3 Nonfusible IEC Style Disconnect Switches
LK3GU3 60 A, 3-pole, use 10x10 shaft 263.00
LK3JU3 100 A, 3-pole, use 10x10 shaft 458.00
LK3MU3ab 200 A, 3-pole, use 10x10 shaft 1010.00
LK3QU3ab 400 A, 3-pole, use 15x15 shaft 1910.00
LK3SU3ab 600 A, 3-pole, use 15x15 shaft 2873.00
LK3TU3ab 800 A, 3-pole, use 15x15 shaft 4301.00
LK3UU3ab 1000 A, 3-pole, use 15x15 shaft 5372.00
LK3WU3ab 1200 A, 3-pole, use 15x15 shaft 6450.00
Compact 30 A Switch
LK3DU3
Example of the parts to order to build a complete GS or LK switch:
Choose a Switch + Shaft + Handle Assembly + Lugs, if needed
600 A, LK3SU3 Shaft 200 mm, GS1AE6 Black Handle, LK3AH150 Lugs Kit, GS1AW503
For example:
LK3SU3 (600 A nonfusible switch, use 15x15 shaft) + GS1AE6 (15x15 200 mm Type H shaft) + LK3AH150 (black/black, lockable)
To add auxiliary contacts:
For front-mounted contacts order GS1AD30 (front-mounted auxiliary contact holder) + GS1AM110 (NO contact for GS1AD10, 20, and 30)
CP1 Discount
Schedule
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-3
17 NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
CP1 Discount
Schedule
IEC Style Disconnect
Switches
GS1 Fusible and LK3 Nonfusible, UL98 Tested
Class 9421 / Refer to Catalog 9421CT0301
Handles
Note: Now UL approved for indoor or outdoor applications.
Table 17.5: Pistol Handles for Compact GS1 and LK3 for Use with Shaft Type D
Type Defeatable Padlockable Color Operation Catalog
Number $ Price
NEMA/UL IEC
1, 12 IP54 Yes Yes Black Off/On (O/I) GS1AH101 51.00
Red/Yellow GS1AH102
Table 17.6: Pistol Handles for Compact GS1 and LK3 for Use with Shaft Type G
Type Defeatable Padlockable Color Operation Catalog
Number $ Price
NEMA/UL IEC
1, 3R, 12 IP54 Yes Yes
Black Off/On (O/I) GS1AH110 62.00
Red/Yellow Off/On (O/I) GS1AH120 62.00
Black Test/Off/On (T/O/I) GS1AHT110 117.00
Red/Yellow Test/Off/On (T/O/I) GS1AHT120 117.00
1, 3R, 4, 4X, 12 IP65 Yes Yes
Black Off/On (O/I) GS1AH410 46.60
Red/Yellow Off/On (O/I) GS1AH420 46.60
Black Test/Off/On (T/O/I) GS1AHT410 78.00
Red/Yellow Test/Off/On (T/O/I) GS1AHT420 78.00
Table 17.7: Pistol Handles for Standard GS1 and LK3
Type Defeatable Padlockable Color Operation Catalog
Number $ Price
NEMA/UL IEC
GS1 30–100 A and LK3 60–100 A (3 in. handles)
1, 3R, 12 IP54 Yes Yes
Black Off/On (O/I) GS1AH110 62.00
Red/Yellow Off/On (O/I) GS1AH120 62.00
Black Test/Off/On (T/O/I) GS1AHT110 117.00
Red/Yellow Test/Off/On (T/O/I) GS1AHT120 117.00
1, 3R, 4, 4X, 12 IP65 Yes Yes
Black Off/On (O/I) GS1AH410 70.00
Red/Yellow Off/On (O/I) GS1AH420 70.00
Black Test/Off/On (T/O/I) GS1AHT410 117.00
Red/Yellow Test/Off/On (T/O/I) GS1AHT420 117.00
GS1 200–400 A and LK3 200 A (5 in. handles)
1, 3R, 12 IP54 Yes Yes
Black Off/On (O/I) GS1AH130 70.00
Red/Yellow Off/On (O/I) GS1AH140 70.00
Black Test/Off/On (T/O/I) GS1AHT130 125.00
Red/Yellow Test/Off/On (T/O/I) GS1AHT140 125.00
1, 3R, 4, 4X, 12 IP65 Yes Yes Black Off/On (O/I) GS1AH430 78.00
Red/Yellow Off/On (O/I) GS1AH440 78.00
Table 17.8: Pistol Handles for Use with Shaft Type H
Type Defeatable Padlockable Color Operation Catalog
Number $ Price
NEMA/UL IEC
For LK3 400–1200 A
1, 3R, 4, 4X, 12 IP65
No
Ye s
Black
Off/On (O/I)
LK3AH150 233.00
No Red/Yellow LK3AH160 233.00
Ye s B l a c k LK3AH170 386.00
Yes Red/Yellow LK3AH180 386.00
For GS1 600–800 A
1, 3R, 4, 4X, 12 IP65
No
Ye s
Black
Off/On (O/I)
LK3AH150 233.00
No Red/Yellow LK3AH160 233.00
Ye s B l a c k GS1AH170 386.00
Yes Red/Yellow GS1AH180 386.00
Table 17.9: Shafts
Length Catalog No. $ Price
in. mm
Shaft 5 mm x 5 mm—For use with Pistol Handles, Type D
12.6 320 GS1AE7 18.60
15.7 400 GS1AE71 23.30
Shaft 5 mm x 5 mm—For use with Pistol Handles, Type G
12.6 320 GS1AE8 18.60
15.7 400 GS1AE81 23.30
Shaft 10 mm x 10 mm—For Standard GS1 and LK3
12.6 320 GS1AE2 20.30
15.7 400 GS1AE21 24.90
Shaft 15 mm x 15 mm—For use with Pistol Handles, Type H
7.9 200 GS1AE6 32.60
15.7 400 GS1AE61 40.40
Type D—alternate handles
for compact switches only
Compact Shaft Kits
GS1AH101 GS1AH102
GS1AE7/AE71 Shafts
5 mm x 5 mm
Type G—Standard Handle Design
Use these shaft kits when
using compact switches:
GS1AE8/AE81 Shafts
5 mm x 5 mm
GS1AH110 GS1AH120
LK3AH160 GS1AE6
www.schneider-electric.us
17-4 © 2012 Schneider Electric
All Rights Reserved
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
CP1 Discount
Schedule
IEC Style Disconnect
Switches
GS1 Fusible and LK3 Nonfusible, UL98 Tested
Class 9421 / Refer to Catalog 9421CT0301
Accessories
aCannot be mixed. A single switch must use all GS1AN11/GS1AN22 contact blocks or all GS1ANT11/GS1ANT22
contact blocks. A GS1AN • contact block may not be used on the same switch as a GS1ANT •.
bGS1 600–800 A and LK3 800–1250 A can receive 1 lug for 3 cables per terminal or 2 lugs for 2 cables per terminal.
cAll GS1 and LK3 switches supplied with line side shrouding.
dThree-piece kit for either line or load side.
Table 17.10: Auxiliary Contacts
Type Description Catalog No. $ Price
For Compact LK3 / GS1
U = Upper or
Top mounted
Standard products allow up to 4 auxiliary contacts without any extra
contact holders. Contact holder (for 5 to 8 auxiliary contacts) GS1AD10 46.70
10 A 1 N.O. Contact Block GS1AM110 14.70
600 Vac 1 N.C. Contact Block GS1AM101 14.70
For LK3 60–200 A, GS1 30–400 A
U = Upper or
Top mounted Contact holder required (for 1 to 8 upper auxiliary contacts) GS1AD20 46.70
10 A 1 N.O. Contact Block GS1AM110 14.70
600 Vac 1 N.C. Contact Block GS1AM101 14.70
S = Side mounted a1 N.O. & N.C. Contact Block (max of two blocks—any mix) GS1AN11 78.00
2 N.O. & N.C. Contact Block (max of two blocks—any mix) GS1AN22 140.00
S = Side mounted a1 N.O. & N.C. Contact Block w/ Test (max of two blocks—any mix) GS1ANT11 93.00
2 N.O. & N.C. Contact Block w/ Test (max of two blocks—any mix) GS1ANT22 156.00
For LK3 400–1200 A
U = Upper or
Top mounted Contact holder (for 1 to 4 auxiliary contacts) LK3AD30 46.70
10 A 1 N.O. Contact Block GS1AM110 14.70
600 Vac 1 N.C. Contact Block GS1AM101 14.70
For GS1 600–800 A
Micro-switch
(top mounted)
1 N.O./N.C. Contact GS1AMU3 57.00
2 N.O./N.C. Contact GS1AMU4 83.00
Table 17.11: Terminal Lugs
For Use On Wire Size # of Wires
per Lug Wire Type Lugs
per Kit Catalog No. $ Price
Compact GS1/LK3 #14–#10 1 Cu Standard
GS1 30 A CC #14–#10 1 Cu Standard
GS1 30 A J #14–#10 1 Cu Standard
GS1/LK3 60 A J #10–#3 1 Cu Standard
LK3 100 A #14–#2/0 1 Cu Standard
GS1 100 A #14–2/0 1 Cu/Al 6 GS1AW303 59.00
GS1/LK3 200 A #6–3/0 1 Cu/Al 6 GS1AW403 98.00
GS1/LK3 400–600 A b2 x 2–2 x 600 2 Cu/Al 6 GS1AW503 197.00
GS1/LK3 800 A / LK3 1000 A b3 x 2–3 x 600 3 Cu/Al 6 GS1AW803 246.00
LK3 1250 A b4 x 2–4 x 600 2 Cu/Al 12 GS1AW903 395.00
Table 17.12: Terminal Shrouds
For Use On Catalog No. $ Price
For Line or Load Side c
Compact GS1/LK3 Standard
All GS1/LK3 30 A Standard
All GS1/LK3 60 A Standard
LK3 100 A Standard
GS1 100 A dGS1AP33 101.00
GS1/LK3 200 A dGS1AP43 132.00
GS1 400 A GS1AP63 213.00
LK3 400–600 A LK3AP63 86.00
GS1 600–800 A GS1AP83 140.00
LK3 800–1250 A LK3AP83 101.00
Table 17.13: Shorting Links
For Use On Shorting Links
per Kit Catalog No. $ Price
GS1 60 A
3
GS1AU203 29.60
GS1 100 A GS1AU303 41.90
GS1 200 A GS1AU403 62.10
GS1 400 A GS1AU503 93.00
GS1 600–800 A GS1AU803 156.00
Table 17.14: Shaft Padlocking Kit
For Use On Catalog No. $ Price
Compact GS1/LK3
Standard
LK3 60–200 A
GS1 30–400 A
LK3 400–1250 A
GS1AD10 +
GS1AM110
GS1AD20 +
GS1AM110
GS1AD30 +
GS1AM110
Terminal Lugs
Terminal Shrouds
Shorting Links
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-5
17 NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
CP1 Discount
Schedule
IEC Style Disconnect
Switches
GS1 Fusible and LK3 Nonfusible, Dimensions
Class 9421 / Refer to Catalog 9421CT0301
Dimensions
25.6
1
37.3
FIX
15
116
79.5
96.5
45
18.3
M 5
FIX
3
16
ø
2
ø 4.5
ø 31
50
90°
2
-OFF
-ON
Door Drilling
83.8
3.25
65
2.5
63
2.48
1.83
2.75
70
76.2
3.0
50
90°
65°
o
2.0
50
2.0
ø 31
1.25
4 ø 4.5
0.13
-ON
-OFF
GS1AH/AHT110, 120, 410, or 420
0.125
1.25
3.75
0.59
1.47
3.125
4.56
1.78
0.72
Test Position
GS1DDU3
Compact CC
30 A
GS1AH110 or 120
2.75
70
65°
o
GS1AH/AHT110, 120, 410, or 420
4.13
105.5
1.47
37.3
0.059
15
4.56
116
3.38
84
0.63
15.8
1.0
28
3.0
7.62
2.48
63
2.0
50
2.0
50
FIX
FIX ø 0.19
1.83
46.5
2.5
65
3.88
99
OFF
0.13
2 ø 4.5
ø 31
1.25
90°
-ON
0.13
2 ø 4.5
ø 31
1.25
2.0
50
-OFF
90°
-ON
Door Drilling
Test Position
GS1DU3
Compact J
30 A
GS1EEU3,
GS1
CC
30 A
1.13 Fix
29
90°
65°
Test Position
-ON
5.69
144
5.88
149
2.00
50
2.00
50
2.75
70
3.00
76.2
3.88
99
2.44
62
2.63
67 1.25
Ø 31
0.13
4 Ø 4.5
0-OFF
Fix 5.25
133
Door Drilling
Dimensions: in.
mm
17-6 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
CP1 Discount
Schedule
IEC Style Disconnect
Switches
GS1 Fusible and LK3 Nonfusible, Dimensions
Class 9421 / Refer to Catalog 9421CT0301
90°
65°
Test Position
-ON
Door Drilling
2.00
50
2.00
50
1.25
Ø 31
.13
4 Ø 4.5
0-OFF
1.50
38
5.88
149
2.75
70
6.75
171
2.63
67
2.75
70
3.00
76.2
Fix
5.25
133
5.63
143
3.50
89
Mounting Hole
Dimension:
0.19 in. (4.8 mm)
GS1EU3/GS1GU3,
GS1
30 A/60 A J
Terminal Lugs 2/0 Max.
90°
65°
Test Position
-ON
Door Drilling
2.00
50
2.00
50
1.25
Ø 31
Ø6.9
.75
19
.63
16
.88
22
0.13
4 Ø 4.5
0-OFF
2.06
52
7.19
183
8.25
210
3.31
84
3.31
84
2.75
70
3.00
76.2
Fix 6.56
167
5.63
1433.44
87.25
GS1JU3,
GS1
100 A J
Mounting Hole
Dimension:
0.19 in. (4.8 mm)
Terminal Lugs 3/0 Max.
90°
65°
Test Position
-ON
Door Drilling
2.00
50
1.00
25
1.13
29
1.50
38
2.00
50
.44
11Ø1 1.6
.13
4 Ø 4.5
1.25
Ø 31
0-OFF
Fix 2.44
62
8.13
207
9.44
240
3.69
94
3.75
95
Fix 7.50
191
2.75
70
6.00
152 3.44
87
5.00
127
GS1MU3,
GS1
200 A J
Mounting Hole
Dimension:
0.19 in. (4.8 mm)
GS1QU3,
GS1
400 A J
Mounting Hole
Dimension:
0.25 in. (6.3 mm)
90°
65°
Test Position
-ON
Door Drilling
Terminal Lugs
2 x 600 MCM Max.
2.00
50
1.50
38
3.13
80
2.88
73
2.00
50
0.13
4 Ø 4.5
1.25
Ø 31
0-OFF
.38
10
Ø 10.2
Fix 2.81
72
Fix 8.81
224
2.81
72
14.31
363
11.94
303
2.06
52
4.44
112
2.75
70
5.00
127
5.56
141 3.44
87
Ø .25
6
Dimensions: in.
mm
Door Drilling
Terminal Lugs
2X600 MCM Max. 3X600 MCM Max.
2.50
64
19.38
492 6.00
152
2.38
59 4.75
120 4.75
120 4.00
100
3.88
98
7.50
190
7.50
190
4.13
106
3.13
80
2.75
69
3.13
803.56
91 1.56
40
2.50
64
2.88
733.00
76
1.50
38
.50
13
.25
7
9.88
250
14.25
362
20.38
517
1.50
38 7.13
181
Ø 9.38 Fix 13.63
346
Fix 9.88
251
Locking
55˚
Ø .38
10
Ø 44
11
Ø 1.25
31
2.00
51
2.00
51
0.13
Ø 4.5
GS1SU3/GS1TU3,
GS1
600 A J
and 800 A L
Mounting Hole
Dimension:
0.38 in. (9.6 mm)
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-7
17 NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
CP1 Discount
Schedule
IEC Style Disconnect
Switches
GS1 Fusible and LK3 Nonfusible, Dimensions
Class 9421 / Refer to Catalog 9421CT0301
90°
Door Drilling
4.56
116
3.78
96
1.94
37
0.59
15
1.00
25
1.00
25
2.00
51
0.75
19
1.83
46
2.59
66
2.48
63
3.84
98
1.78
45
0.72
18
0.56
14
Fix
3.13
80
Fix
Ø .19
M5
-ON
0-OFF
1.25
Ø 31
0.13
2 Ø 4.5
Mounting Hole
Dimension:
0.19 in. (4.8 mm)
LK3DU3,
Compact LK3
30 A
ø 0.19
5FIX 1.50
38
5.88
149
70
170
6.69
2.75
FIX 5.25
133
67
2.63 76.2
3.00
70
2.75
99
3.88
89
3.50
90°
65°
Test Position
-ON
Door Drilling
2.00
50
2.00
50
.13
4 Ø 4.5
1.25
Ø 31
0-OFF
LK3GU3/LK3JU3,
LK3
60 A/100 A
Mounting Hole
Dimension:
0.19 in. (4.8 mm)
Terminal Lugs 3/0 Max.
90°
65°
Test Position
-ON
Door Drilling
2.00
50
1.00
25
1.13
1.50
38
2.00
50
.44
11
Ø11.6
0.13
4 Ø 4.5
1.25
Ø 31
0-OFF
8.13
206
2.44
62
9.50
241
3.69
94
3.75
95
2.75
70
3.44
87
5.00
127
Ø
.19
5
Fix
7.50
191
29
LK3MU3,
LK3
200 A
Mounting Hole
Dimension:
0.19 in. (4.8 mm)
Door Drilling
Terminal Lugs
2 x 600 MCM Max.
1.50
38
3.13
80
2.88
73
.38
10
Ø 10.2
.13
4 Ø 4.5
1.25
Ø 31
2.00
51
2.00
51
0.81
20
11.00
279
0.56
14
7.50
191
3.88
98
6.56
166 1.63
41
2.31
59
5.00
127
1.56
40
3.13
80
Fix 10.06
255
Fix 6.88
175
Fix 12.63
320
LK3QU3/LK3SU3,
LK3
400 A/600 A
Mounting Hole
Dimension:
0.25 in. (6.3 mm)
Dimensions: in.
mm
Door Drilling
Terminal Lugs
2X600 MCM Max. 3X600 MCM Max.
3.13
803.56
91 1.56
40
2.50
64
2.88
733.00
76
1.50
38
Ø .38
10
Ø 44
11
Ø 1.25
31
2.00
51
6.56
166 1.56
40
2.00
51
0.13
Ø 4.5
0.81
20
0.81
20
2.31
59
1.56
40
14.63
372
6.81
1734.75
121
13.00
330
7.50
191
3.88
98
2.50
64
Fix 6.88
175
Fix 13.69
347
LK3TU3/LK3UU3/
LK3WU3,
LK3
800 A/1000 A/1250 A
Mounting Hole
Dimension:
0.38 in. (9.6 mm)
www.schneider-electric.us
17-8 © 2012 Schneider Electric
All Rights Reserved
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
UL508 Motor Disconnect
Switches
Mini-Vario and Vario™ Switches
Refer to Catalog 9421CT0301
Vario
The Vario Motor Disconnect Switch is also offered as an enclosed switch made of corrosion
resistant material. The 3-pole version makes the Vario switch ideal for manual motor control
applications. The switches are compact, easy to wire and connect, and come undrilled to
allow variable cable entry positions.
NOTE: VCGUN enclosures are UL approved.
aAssembled, includes switches mounted in enclosure with handle.
aUL Rated, NEMA Type 1, 12, IP55.
Table 17.15: Non-Metallic Enclosed Switches a
Ampere Size IP55-PVC 3-Pole, NEMA Type 1 & 12
UL IEC Catalog No. $ Price
20 32 VC1GUN 239.00
25 40 VC2GUN 287.00
45 63 VC3GUN 345.00
63 80 VC4GUN 381.00
100 125 VC5GUN 548.00
115 175 VC6GUN 845.00
Table 17.16: Non-Metallic Enclosed Switch Dimensions a
Catalog No. a
No.
of
Poles
Dimensions
a b c d e f
in. mm in. mm in. mm in. mm in. mm in. mm
VC1GU–VC2GU
3
6.7 170 4.1 105 3.2 82 4.8 122 2.1 53 5.0 128
VC3GU–VC4GU 6.7 170 5.3 135 3.3 85 5.1 130 3.7 95 5.2 131
VC5GU–VC6GU 11.0 280 8.6 220 5.0 126 7.9 201 7.5 190 8.6 203
Table 17.17: Vario Manual Motor Control Switches, IEC
Rating (A)
IEC
kW Rating 3-Pole Switch Body
230 V 240 V 400 V 415 V 500 V 690 V
20 4 4 5.5 5.5 7.5 11
25 5.5 5.5 7.5 7.5 11 15
32 5.5 5.5 11 11 11 15
40 7.5 7.5 15 15 18.5 15
63 15 15 22 22 30 22
80 18.5 18.5 30 30 37 30
125222237374537
175303045455545
Non-Metallic Enclosure
Ø 6.2
.25
e
b
da
c
f
Legend
Plate
Holder
VC1GU–VC6GU
CP1 Discount
Schedule
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-9
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
NEMA Style Disconnect
Switches
NEMA Style Door-Mounted Disconnect Switches
Refer to Catalog 9420CT9701
aNonfused ratings.
aOne block per switch.
Note: These switches are for motor circuit applications.
aOne conductor per lug.
aContinuous current should not exceed switch rating (size).
Fuse clip kits should be sized to accommodate inrush.
File D10
The D10 disconnect switch features high I2T rating, longer contact life, visible contact indication, fuse-mounting flexibility, dead-front construction,
and auxiliary interlocks.
A complete installation includes a D10 disconnect switch, D11 handle operator, and D12 fuse clip kit. The D10 accepts Class H, K, J, or R fuses, or
can be used for nonfusible applications. The D10 disconnect switch is operated by a cast metal handle operator that is lockable in the “Off” position
and defeatable in the “On” position.
Table 17.18: Disconnect Switches
(without fuse clips or shorting straps)
600 V—Without Service Entrance Rating
Starter
NEMA
Size
Rating
(A)
Max. Horsepower Ratinga
Catalog
Number $ Price
120 V 200–
240 V 480 V 600 V
0–1 30 5 10 20 25 D10S1 270.00
26010204050D10S2 292.00
3 100 15 30 60 75 D10S3 452.00
4 200 25 50 100 100 D10S4 860.00
600 V—With Service Entrance Rating
Starter
NEMA
Size
Rating
(A)
Max. Horsepower Rating a
Catalog
Number $ Price
120 V 200–
240 V 480 V 600 V
0–1 30 5 10 20 25 D10S1H 320.00
26010204050D10S2H 352.00
3 100 15 30 60 75 D10S3H 544.00
4 200 25 50 100 100 D10S4H 1154.00
Table 17.19: Rotary Handle Operator Kits and Shafts
Kits include: Handle, Shaft, and Actuator
NEMA Type 1, 3, 3R, 4, and 12
Description Rating
(A)
Enclosure Interior
Depth—Inches
Catalog
Number $ Price
Complete Kit with
Handle, Shaft, and
Actuator
30,
60,
100,
200
5–6 D11SF4 106.00
6–10 D11SF10 118.00
10–16 D11SF16 130.00
Shaft only 6D11SH10 26.20
12 D11SH16 32.80
Table 17.20: Auxiliary Electrical Interlock
(for mounting on 30–200 A disconnect switch a)
Block Description
(with switch contacts open)
Catalog
Number $ Price
1 N.O. D11N0 79.00
1 N.C. D11NC 79.00
1 N.O. and 1 N.C. D11N0C 116.00
2 N.O. D11N00 116.00
2 N.O. and 2 N.C. D11N0C2 130.00
Table 17.21: Interrupting and Withstandability
Ratings
Rating
(A)
Interrupting Rating
Amperes Symmetrical
600 Vac, 3Ø
Withstandability I2T
(Amperes2 seconds)
30 1,200 0.38 x 106
60 1,800 1.28 x 106
100 2.000 2.62 x 106
200 3,600 5.25 x 106
Line Shield
Centerline
of Switch
Operating
Shaft
IJ
D
A
B
E
FH
C
G
Table 17.22: Lug Data
Rating (A) Number
Per Pole Wire RangeaWire Type
30
1
#14–#8 Cu
60 #14–#4 Cu
100 #14–#1/0 Al–Cu
200 #6–250 kcmil Al–Cu
Table 17.23: Fuse Clip Kits
D10
Switch Size
Fuse Clip Rating aCatalog
Number $ Price
Amperes AC Volts Type
30 A
No Fuse D12C01 8.30
0–30 250 H, K D12C21 16.30
0–30 250 R D12CR21 65.00
0–30 600 H, K D12C61 24.50
0–30 600 R D12CR61 65.00
0–30 600 J D12CJ1 49.30
31–60 250 H, K D12C22 24.50
31–60 600 H, K D12C62 49.30
31–60 600 R D12CR62 82.50
31–60 600 J D12CJ2 57.50
61–100 250 H, K D12C23 65.00
60 A
No Fuse D12D02 24.50
0–30 250 R D12DR21 65.00
0–30 600 H, K D12D61 24.50
0–30 600 R D12DR61 65.00
31–60 250 H, K D12D22 23.80
31–60 250 R D12DR22 82.50
31–60 600 H, K D12D62 41.00
31–60 600 R D12DR62 82.50
31–60 600 J D12DJ2 57.50
61–100 250 H, K D12D23 65.00
61–100 600 H, K D12D63 115.00
61–100 600 J D12DJ3 106.30
61–100 600 R D12DR63 113.80
100 A
No Fuse D12E03 49.30
31–60 250 H, K D12E22 41.00
31–60 600 H, K D12E62 41.00
61–100 250 H, K D12E23 32.50
61–100 250 R D12ER23 115.00
61–100 600 H, K D12F63 90.00
61–100 600 R D12FR63 115.00
61–100 600 J D12EJ3 115.00
101–200 250 H, K D12F24 106.30
101–200 600 H, K D12F64 122.50
101–200 600 J D12FJ4 140.00
200 A
No Fuse D12F04 82.50
61–100 600 H, K D12F63 90.00
101–200 250 H, K D12F24 106.30
101–200 250 R D12FR24 140.00
101–200 600 H, K D12F64 122.50
101–200 600 R D12FR64 135.00
101–200 600 J D12FJ4 140.00
Table 17.24: Switch Dimensions (in inches)
Rating
(A)
Length Width Mounting Hole Dimensions Depth
A B C D E F G H I J Kalb
30 7-5/16 4-15/32 5-7/8 3-15/32 6 3-15/32 1-7/8 13/32 5-7/16 3-1/4 4-3/32 4-11/32
60 7-5/16 4-15/32 5-7/8 3-15/32 6 3-15/32 1-7/8 13/32 5-7/16 3-1/4 4-11/32 4-11/32
100 9-27/32 5-11/32 8-3/16 4-5/8 5-13/16 3-13/16 2-11/16 51/64 7-5/16 4-3/16 5-23/32 4-27/32
200 12-3/16 7-7/32 8-3/16 4-5/8 5-13/16 3-13/16 2-11/16 51/64 7-5/16 4-3/16 5-23/32 4-27/32
aMaximum depth with largest fuse.
bDepth including insulating barrier on service entrance switches.
CP1 Discount
Schedule
17-10 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Door-Mounted Operating
Mechanisms
For Square D™ Circuit Breakers
Class 9421 / Refer to Catalog 9420CT9701
Type L Circuit Breaker Mechanisms
Type L door-mounted, variable-depth operating mechanisms feature heavy duty, all metal construction with trip
indication. All can be padlocked in the “Off” position when the enclosure door is open. Further, the handle assemblies
can be locked “Off” with up to three padlocks, which also locks the enclosure when the door is closed. (The 3” handle
accepts one padlock.) Complete kits are rated for NEMA Type 1, 3R, and 12 enclosures. They include a handle
assembly, operating mechanism, and shaft assembly.
aContains support bracket.
aOptional accessory for use with 9421L operating mechanisms. Not used with GJL, NAL,
NCL, NEL, NXL, NSF, NSJ, PowerPact™ C, D, H, and J circuit breakers; use field-installed
circuit breaker interlocks instead.
Table 17.25: Complete Kits
Complete Kit
Does Not Include Circuit Breaker
Includes:
Operating Mechanism
Standard 6 in. Handle
Standard Shaft Kit
Includes:
Operating Mechanism
Standard 6 in. Handle
Long Shaft Kit
Includes:
Operating Mechanism
Short 3 in. Handle
Long Shaft Kit
Use With
Circuit Breaker or
Interrupter Type
No.
of
Poles
Frame
Size
(A)
Type $ Price
Mounting
Depth a
Min. – Max.
Type $ Price
Mounting
Depth a
Min. – Max.
Type $ Price
Mounting
Depth a
Min. – Max.
GJL 3 75, 100 LG1 140.00 5-1/2–10-1/4 LG4 158.00 5-1/2–20-7/8 LG3 198.00 5-1/2–20-7/8
FAL, FCL, FHL 2–3 100 LN1 140.00 5-1/2–10-7/16 LN4 158.00 5-1/2–21 LN3 198.00 5-1/2–21
KAL, KCL, KHL 2–3 250 LP1 171.00 6-1/4–11-3/16 LP4 189.00 6-1/4–21-3/4 LP3 230.00 6-1/4–21-3/4
LALc, LHLc, Q4L 2–3 400 LR1 242.00 6-5/16–10-7/8 LR4 255.00 6-5/16–21-1/2 LJ3 230.00 5-1/2–21-3/8
MEL, MXL 2–3 800 LT1 b242.00 7-3/16–11-5/8 LT4 b255.00 7-3/16–22-1/4
3 in. handles are not recommended
for use with these circuit breakers.
MAL, MHL 2–3 1200 LT1b242.00 7-3/16–11-5/8 LT4b255.00 7-3/16–22-1/4
NAL, NCL, NEL, NXL 2–3 1200 LX1b242.00 8-1/4–12-3/4 LX4b255.00 8-1/4–23-3/8
Table 17.26: Component Parts
Use With
3 in. Handle
Assemblies
Type 1, 3R, 12
Standard
Handle
Assemblies
Type 1, 3R, 12
Operating
Mechanism
(Lockout
Included)
Standard Shaft
(Support Bracket
Not Required)
Long Shaft
(Support Bracket
Included)
Circuit Breaker or
Interrupter Type
No.
of
Poles
Frame
Size
(A)
Type $ Price Type $ Price Type $ Price
Mounting
Depth a
Min. – Max.
Type $ Price
Mounting
Depth a
Min. – Max.
Type $ Price
GJL 3 75, 100 LH3 90.00 LH6 50.00 LG7 68.00 5-1/2–10-7/16 LS8 21.50 5-1/2–21 LS13 35.60
FAL, FCL, FHL 2–3 100 LH3 90.00 LH6 50.00 LF1 71.00 5-1/2–10-7/16 LS8 21.50 5-1/2–21 LS12 35.60
KAL, KCL, KHL 2–3 250 LH3 90.00 LH6 50.00 LK1 105.00 6-1/4–11-3/16 LS8 21.50 6-1/4–21-3/4 LS12 35.60
LALc, LHLc, Q4L 2–3 400 3 in. handles
are not
recommended
for use with
these circuit
breakers.
LH6 50.00 LL1 170.00 6-5/16–10-7/8 LS8 21.50 6-5/16–21-1/2 LS10 35.60
MEL, MXL 2–3 800 LH8 50.00 LM1 170.00 7-3/16–11-5/8 LS8 21.50 7-3/16–22-1/4 LS10 35.60
MAL, MHL 2–3 1200 LH8 50.00 LM1 170.00 7-3/16–11-5/8 LS8 21.50 7-3/16–22-1/4 LS10 35.60
NAL, NCL, NEL, NXL 2–3 1200 LH8 50.00 LX7 170.00 8-1/4–12-3/4 LS8 21.50 8-1/4–23-3/8 LS10 35.60
aMounting depth in inches, measured from circuit breaker mounting surface (control panel) to outside of enclosure door.
bTypes LT1, LT4, LX1, and LX4 include an 8 in. handle rather than a 6 in. handle.
cThese operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix.
Table 17.27: NEMA Type 4 and 4X Handle Assemblies a
Use With Standard Handle Assemblies 3 in. Handle Version
Circuit Breaker or
Interrupter Type
No.
of
Poles
Frame
Size
(A)
NEMA Type 1, 3R,
4, 12
(Painted)
NEMA Type 1, 3R,
4, 4X, 12
(Chrome Plated)
NEMA Type 1, 3R,
4, 12
(Painted)
NEMA Type 1, 3R,
4, 4X, 12
(Chrome Plated)
Type $ Price Type $ Price Type $ Price Type $ Price
GJL 3 75 LH46 90.00 LC46 149.00 LH43 165.00 LC43 233.00
FAL, FCL, FHL 2–3 100 LH46 90.00 LC46 149.00 LH43 165.00 LC43 233.00
KAL, KCL, KHL 2–3 250 LH46 90.00 LC46 149.00 LH43 165.00 LC43 233.00
LAL, LHL, Q4L 2–3 400 LH46 90.00 LC46 149.00
3 in. handles are not recommended
for use with these circuit breakers.
MEL, MXL 2–3 800 LH48 90.00 LC48 149.00
MAL, MHL 2–3 1000 LH48 90.00 LC48 149.00
NAL, NCL, NEL, NXL 2–3 1200 LH48 90.00 LC48 149.00
aDue to gasketing, NEMA Type 3 and 4 handle assemblies are not trip indicating.
Table 17.28: IEC Style Operating Mechanisms
Circuit Breaker or
Interrupter Type
Type 1, 4, 4X, 12 Operating Mechanism
(Lockout Included)
Extension Shafts
Mounting Depth Type $ Price
Color Type $ Price Type $ Price Min. Max.
GJL Red/Yellow NW3 90.00 LG8 71.00 6-1/8 10-3/4 NS16 28.70
Black NW3B 90.00 6-1/8 17-7/8 NS336a35.60
Table 17.29: Electrical Interlock Kits—Class 9999 a
Description Class Type $ Price
Single-Pole, Double-Throw 9999 R47 131.00
Double-Pole, Double-Throw 9999 R48 221.00
Operating
Mechanism
3 in. Handle
Assembly
Standard
Handle
Assembly
CP1 Discount
Schedule
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-11
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Approximate
Dimensions
Door-Mounted Operating Mechanisms
Class 9421 / Refer to Catalog 9420CT9701
aMounting depth measured from circuit breaker mounting surface (control panel) to outside of enclosure door.
Table 17.30: Shaft Cutting Dimensions
Class Type Shaft Length
Formula
H = Standard Shaft H = Long Shaft
Min. Max. Min. Max.
9421 LG7, LG1, LG4, LG3 L = H–2.50 5.50 10.25 5.50 20.85
64 140 260 140 530
9421 LF1, LN1, LN3, LN4 L = H–2.88 5.50 10.44 5.50 21.00
73 140 265 140 533
9421 LK1, LP1, LP3, LP4 L = H–3.63 6.25 11.19 6.25 21.75
92 159 284 159 552
9421 LL1, LR1, LR4 L= H–3.13 6.31 10.88 6.31 21.50
79 160 276 160 546
9421 LM1, LT1, LT4 L= H–4.00 7.18 11.63 7.18 22.25
102 182 295 182 565
9421 LX7, LX1, LX4 L= H–5.17 8.25 12.75 8.25 23.38
131 210 324 210 594
Handle Mechanism
Handle
Mechanism
(2) #8-32 Tap
2.38
60
L
H
Mounting Depth
.28
Maximum
7 Door Thickness
L = Overall shaft length
H = Distance from inside of enclosure door to circuit
breaker mounting surface
1.38
35
3.50
Min.
45
1.18
30
.50
13
.45
12
4.72
120
1.77
45
3.94
100
Screw Driver
Interlock Pin
Location
CL
CL
X
Refer to NEC
Article 430-10
for minimum
dimension from
top mounting hole
to wall or barrier
to ensure adequate
wire bending space.
Panel drilling for GJL circuit breaker
and operating mechanism
a
2.25
57
1.50
38
7.00
178
1.6 3
41
6.00
152
R
5.13
130
(4) #8-32 Tap
1.56
40
.75
19
4.50
114
Hinge
Point of
Door
C
L Handle
Mechanism
C
L Handle & Ckt. Bkr. Toggle
Minimum to wall or
barrier to ensure
adequate wire bending
space to lug surface
when maximum wire
size is used with
standard lugs.
Refer to NEC Article
430-10.
3.25
Minimum
83 (Both Sides)
Panel drilling for FAL, FCL, and FHL
circuit breakers and operating mechanisms
3.25 Minimum
83 (Both Sides)
2.25
57
1.50
38
13.50
343
1.6 3
41
6.00
152
R
7.13
181
(4) #10-24 Tap
C30080-120
1.81
46
.75
19
4.50
114
Hinge
Point of
Door
C
L Handle & Ckt. Bkr. Toggle
Minimum to wall or
barrier to ensure
adequate wire bending
space to lug surface
when maximum wire
size is used with
standard lugs.
Refer to NEC Article
430-10.
Dimensions: in.
mm
Panel drilling for KAL, KCL, and KHL
circuit breakers and operating mechanisms
17-12 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Approximate
Dimensions
Door-Mounted Operating Mechanisms
Class 9421 / Refer to Catalog 9420CT9701
(4) 1/4-20 Tap
C
L Handle
C
L
Circuit Breaker
C
L Handle
9.25
235
4.57
116
6.00
152
19.19
487
.88
22
.88
22
6.00
Minimum
152 (Both Sides)
Hinge
Point
of Door Minimum to wall or barrier
to ensure adequate wire
bending space to lug surface
when maximum wire size is
used with standard lugs.
Refer to NEC Article 430-10.
4.68
119
7.19
183
(4) #12-24 Tap
2.68
68
.56
14
6.00
152
.44
11
.38
10
3.00
76
2.00
51
1.00
25
1.59
40
1.63
R
41
2.00
51
C
L
Circuit Breaker
4.50
114 3.00
76
3.09
79
3.50
89
1.66
42
A
B
4.937
125
8.00
203
.38
10
.44
11
1.63R
41
1.03
26
(4) 5/16-18 Tap
(4) 1/4-20 Tap
Minimum to wall or
barrier to ensure
adequate wire bending
space to lug surface
when maximum wire
size is used. Refer to
NEC Article 430-10.
2.00
51
1.50
38
9.00
229
Hinge
Point
of
Door
5.09
129
10.19
259
X
8.00 Minimum
203 (Both Sides)
C
L
Handle
C
L
Handle
Panel drilling for LAL, LHL, and Q4L
circuit breakers and operating mechanisms
Panel drilling for MAL, MEL, MHL, and MXL
circuit breakers and operating mechanisms
Circuit Breaker Type Dimensions = in. (mm)
A B
MAL, MHL 10.69 (272) 14.00 (356)
MEL, MXL 11.47 (291) 14.75 (375)
Panel drilling for NAL, NCL, NEL, and NXL
circuit breakers and operating mechanisms
9.00 Minimum (Both Sides)
229
7.50
191
8.50
216
8.00
203
12.13
308
9.50
241
8.75
222 1.6 3R
41
1.66
42
5.00
127
3.16
80
2.50
64
(4) 1/4-20 Tap
15.00
381
Hinge
Point
of Door
C
L Handle
Mechanism
C
L
Circuit Breaker
C
L
Handle Mechanism
Dimensions: in.
mm
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-13
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Bracket-Mounted
Disconnect Devices
Type T Disconnect Switches
Class 9422 / Refer to Catalog 9420CT9701
aThese operating mechanisms cannot be used with any LA/LH circuit
breaker with an MB or MT suffix.
Note: Some enclosures may not accept the listed bracket-mounted
operating mechanisms; contact the enclosure manufacturer.
Table 17.32: Electrical Interlock Kits—Class 9999
Optional accessory for use with circuit breaker operating
mechanisms listed to the left and the flexible cable
mechanisms listed below, except GJL.
Note: Not used with GJL; use field installed circuit breaker interlocks.
Table 17.31: Bracket-Mounted Operating Mechanisms for Use With Square D™ Circuit Breakers
The circuit breaker operating mechanisms listed below are shipped with the external operating handle assembled to a
bracket. Circuit breakers are not included and must be ordered separately. A trim plate is provided with each kit to
prevent any mounting screws from being accessible from the front and also to provide an attractive installation.The
operating handle is Type A1. These switches can be used with Class 9423 door closing mechanisms.
Use With
Operating Mechanism
Right Hand
Flange Mounting
Circuit Breaker or
Interrupter Type
No. of
Poles
Frame Size
(A) Cat. No. $ Price
FAL, FHL 2–3 100 BN1 257.00
KAL, KHL 2–3 250 BP1 270.00
LALa, LHLa, Q4L 2–3 400 BR1 543.00
Description Class Type $ Price
Single Pole, Double Throw 9999 R26 131.00
Double Pole, Double Throw 9999 R27 243.00
D
Disconnect
Device
Table 17.33: Dimensions
Type A
in. (mm)
C
in. (mm)
D
in. (mm)
Min. Enclosure Deptha
in. (mm)
F
in. (mm)
BG1, BN1 8.75 (222) 1.13 (29) 6.50 (165) 8.00 (203) 7.13 (181)
BP1 9.13 (232) 7.38 (187)
aThe minimum enclosure depth is greater than Dimension D since additional space is needed when mounting
the mechanism.
Note: Back panel support is recommended for Types TFB1, 2, and 3. Other devices may also require support if the
flange is not sufficiently rigid.
ON
OFF
0.38
10
0.38
10
F
C
AE
0.38
10
Fused
Non Fused
and Circuit
Breaker
Disconnect
Device
(2) 0.38 Dia. Mounting Holes
10
(For back panel support if necessary.)
For use with Square D circuit breakers and Class 9422 A handle operators. Especially designed for tall, deep
enclosures where placement flexibility is required. See Digest 176 page 8-24 for dimensions.
Table 17.34: Class 9422—Flexible Cable Mechanisms for Use With Square D Circuit Breakers
Circuit Breaker
Type
No. of
Poles
Frame Size
(A)
Cable Mechanism Cable Mechanisms with A1 Handle
Cable Length Catalog No. $ Price Catalog No. $ Price
GJL 3 100
36 in. CGJ30 273.00 CGJ31 417.00
48 in. CGJ40 291.00 CGJ41 432.00
60 in. CGJ50 291.00 CGJ51 432.00
120 in. CGJ10 333.00 CGJ11 476.00
FAL, FHL 2, 3 100
36 in. CFA30 273.00 CFA31 417.00
60 in. CFA50 291.00 CFA51 432.00
120 in. CFA10 333.00 CFA11 476.00
KAL, KHL 2, 3 250
36 in. CKA30 288.00 CKA31 431.00
60 in. CKA50 305.00 CKA51 446.00
120 in. CKA10 347.00 CKA11 489.00
LALa, LHLa, Q4L 2, 3 400
36 in. CLA30 486.00 CLA31 630.00
60 in. CLA50 504.00 CLA51 647.00
120 in. CLA10 548.00 CLA11 689.00
aThese operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix.
Table 17.35: Class 9999 Auxiliary Contact Kits for Disconnect Switches and
Circuit Breakers
Class Type
SPDT DPDT
Type $ Price Type $ Price
Disconnect Switches
9422 TF R8 87.00 R9 243.00
Circuit Breaker Operating Mechanisms
9421 LF, LK, LL, LM, LN, LP, LR, LT R47 131.00 R48 221.00
9422 RM, RN, RP, RR, RT R26 131.00 R27 243.00
9422 CFA, CKA, CLA, CSF R26 131.00 R27 243.00
Note: No external auxiliary contacts are available for the following circuit breakers:
GJL circuit breakers must use internal auxiliary contacts, catalog number AAC.
PowerPact D circuit breakers must use internal auxiliary contacts, catalog number AAC.
Note: For additional variations, contact the Customer Care Center (CCC) at 1-888-778-2733.
CP1 Discount
Schedule
www.schneider-electric.us
17-14 © 2012 Schneider Electric
All Rights Reserved
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Flexible Cable
Mechanisms
For Circuit Breakers
Class 9422 / Refer to Catalog 9420CT9701
Dual Cable Operating Mechanisms for Square D™ Circuit Breakers
Dual cable operator mechanisms are designed for use with Square D GJL circuit breakers.
The cable mechanisms allow for a single handle operator, Class 9422A1, to operate both
circuit breakers. The cable mechanism is designed especially for tall, deep enclosures
where placement flexibility is required. There are numerous cable arrangements to choose
from to accommodate many applications.
Features
Separate cables for each circuit breaker
Rugged metal flange handle operator
Maximized flexibility of circuit breaker placement for existing and new applications
Control panel can be fed from two separate supply voltages (if required)
Dual mechanism allows both separate supply voltages to be controlled by a single
handle to improve security features
Table 17.36: Dual Cable Operating Mechanisms Selection
Circuit Breaker Type Cable Length
in. / mm (quantity)
Catalog
Number
Frame Size
(max.) $ Price
GJL
36 in. / 914 mm (2) 9422CGJD3
100 A
585.00
48 in. / 1219 mm (2) 9422CGJD4 608.00
60 in. / 1524 mm (2) 9422CGJD5 675.00
120 in. / 3048 mm (2) 9422CGJD1 788.00
36 in. / 914 mm (1)
60 in. / 1524 mm (1) 9422CGJD8 642.00
60 in. / 1524 mm (1)
120 in. / 3048 mm (1) 9422CGJD9 720.00
Table 17.37: Special Left-hand Mounted Single Cable Operating Mechanisms
Circuit Breaker Type
Cable Length
in. / mm
(quantity)
Catalog
Number
Frame Size
(max.) $ Price
FAL
120 in. / 3048 mm (1) 9422CFAL10
100 A
350.00
36 in. / 914 mm (1) 9422CFAL30 287.00
60 in. / 1524 mm (1) 9422CFAL50 318.00
CP1 Discount
Schedule
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-15
17 NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Disconnect Switch
Accessories
Flange Mounted, Variable Depth
Class 9422 / Refer to Catalog 9420CT9701
Designed for installation in custom built control enclosures where main or branch circuit protective devices are required. All
circuit breaker operating mechanisms are suitable for either right- or left-hand flange mounting, convertible on the job.
aClass 9422 Type R2 will extend mounting depth 7 in.
aNot for use with the GJL operating mechanism.
Table 17.38: Variable-Depth Mechanisms for Use with Square D™ Circuit Breakers and Schneider Electric™
(formerly Merlin Gerin™) Circuit Breakers
Use With Operating Mechanism
Circuit Breaker
Frame Size
No. of
Poles
Frame Size
A
Variable-Depth Mtg.
Range Min.-Max.a
(Inches)
Operating Mechanism
Only—Does Not Include
Handle Mechanism
Operating Mechanism and Handle Mechanism
Includes Type A1
Handle Mechanism
Includes Type A2
Handle Mechanism
Type $ Price Type $ Price Type $ Price
Square D Circuit Breakers
GJL 3 100 6.00–17.75 RG1 116.00 ARG11 257.00 ARG21 372.00
FAL, FHL 2–3 100 5.38–17.75 RN1 116.00 ARN11 257.00 ARN21 372.00
KAL, KHL 2–3 250 6.38–17.88 RP1 129.00 ARP11 270.00 ARP21 386.00
LALc, LHLc, Q4L 2–3 400 7.44–18.25 RR1 329.00 ARR11 471.00 ARR21 585.00
MEL, MXL 2–3 800 9.00–18.38 RT1 449.00 ART11 593.00 ART21 705.00
MAL, MHL 2–3 1200 9.00–18.38 RT1 449.00 ART11 593.00 ART21 705.00
NAL, NCL, NEL, NXL 2–3 1200 11.00–18.37 RX1 513.00 ——— —
Table 17.39: Electrical Interlocks—Class 9999
Description Class Type $ Price
Single Pole, Double Throw
Double Pole, Double Throw
9999
9999
R26a
R27a
131.00
243.00
Table 17.40: Dimensions
Circuit Breaker
Frame Size Type
Width
(A)
Height
(B)
Distance to Enclosure Flangea
(C) Bracket Depth
(D)
Minimum Maximum
in. mm in. mm in. mm in. mm in. mm
GJL RG1 5.00 127 4.75 121 6.00 152 17.75 451 4.00 102
FAL, FHL RN1 6.75 171 8.50 216 5.51 140 17.75 451 4.26 108
KAL, KHL RP1 7.13 181 10.13 257 6.51 165 17.88 454 4.94 125
LALc, LHLc, Q4L RR1 10.19 259 11.00 279 7.44 189 18.25 464 6.00 152
MEL, MXL RT1 13.38 340 14.00 356 9.00 229 18.38 467 9.69 246
MAL, MHLbRT1 13.38 340 14.00 356 9.00 229 18.38 467 9.69 246
NAL, NCL, NEL, NXL RX1 19.63 499 13.50 343 11.00 279 18.37 467 9.00 229
a9422R2 will extend the dimension by 7 in. Two required.
bMinimum mounting depth when using MAL or MHL circuit breakers can be decreased to 7.63 inches by using the
Class 9422 Type RT1B conversion kit. $23.00
cWarning: These operating mechanisms cannot be used with any LA / LH circuit breaker with an MB or MT suffix.
Minimum to wall or barrier.
Right- or left-hand mounting
to ensure adequate wire
bending space to lug
surface when maximum
wire size is used.
Refer to NEC Article 430-10.
C
L
R.H. Handle
C
L L.H. Handle
A
B
D
C = Distance from Outside of
Flange to Circuit Breaker
Mounting Surface
Enclosure Flange
Enclosure Door
CP1 Discount
Schedule
www.schneider-electric.us
17-16 © 2012 Schneider Electric
All Rights Reserved
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Disconnect Switch
Accessories
Flange Mounted, Variable Depth
Class 9422 / Refer to Catalog 9420CT9701
Remote or Dual Adapter Kit
For the remote or dual operation of GJL, FAL, FHL, KAL, KHL, LAL, LHL, Q4L, MAL, MHL,
MEL, and MXL circuit breakers.
Remote Operation—permits mounting the Class 9422 Type A9 or A10 handle mechanism
at a lower level than the disconnect device it controls. This arrangement is often required
where the disconnect device is mounted too high for personnel to easily reach a
conventional operator.
Dual Operation—permits controlling two disconnect devices, one in line with, and one
remote from, a single Class 9422 Type A9 or A10 handle mechanism.
NOTE: A Class 9422 Type A9 or A10 handle (see Digest 176 page 8-15) and the
preferred mounting method must be used.
aPrices do not include air valves or handle mechanism. For more information on the
air valves listed above, contact Parker at c-parker@parker.com, or call 1-800-272-7537.
Table 17.41: Disconnect Device
Disconnect Device
Enclosure Mounting Depth
Type $ Price
Min. Max.
Circuit Breaker
GJL 10.50 19.50
D2 251.00
FAL, FHL 10.66 19.50
KAL, KHL 11.13 19.50
LAL, LHL, Q4L 12.13 19.88
MAL, MHL,MEL, MXL 13.75 20.25
Table 17.42: Air Valve Interlock
Note: Air valve interlocks only accept the specific three-way air valves, manufactured by Parker,
listed in the table below.
Parker Valve Model NumberaClass 9422
Air Valve Interlock
Air Valve Size Knob Operated Type $ Price
0.50 NPT
13
M04841885 G1 513.00
M08541848
0.75 NPT
19
M04861885 G2 513.00
M08561848
1.00 NPT
25 M00080004 G1 513.00
Table 17.43: Other Accessories
Accessory Description Class Type $ Price
Channel/Flange
Support Kit
Auxiliary kit recommended for use with 30 A and 60 A disconnect switches
and FAL, FCL, FHL, KAL KHL, NSF, and NSJ circuit breaker mechanisms
when these devices are to be mounted on the center channel of a multi-door
enclosure or when extra rigidity for the flange is required. Supplied as
9422 C1 42.80
Switch
or
Breaker
Remote operation shown
(handle mechanism not
included in kit)
Air valve interlock
mounted on enclosure
Alternate Mounting Kit
Channel/Flange
Support Kit
Auxiliary Lock Plate
CP1 Discount
Schedule
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-17
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Reversing Drum Switches Type A and B
Class 2601 / Refer to Catalog 2510CT9701
NEMA Types 1, 3R, 4, and 13 Without Overload
Class 2601 reversing drum switches may be used for across-the-line starting and reversing of AC polyphase, AC single
phase or DC motors, where overload protection is not required or is provided separately. They are compact and
inexpensive but ruggedly constructed. Drum switches are field convertible from maintained-only to momentary-only
operation. This conversion consists of removing the handle screw and handle, turning the shaft 180 degrees, then
replacing the handle and handle screw.
aMaintained – “Forward”; Momentary – “Reverse”; (not field convertible)
Approximate Dimensions—Class 2601 Reversing Drum Switches
Table 17.44: Reversing Drum Switches
600 Vac Maximum Class 2601 360 Vdc Maximum
Ratings NEMA Type 1
General Purpose
Enclosure
NEMA Type 4
Watertight and
Dusttight Enclosure
NEMA Type 1
Maintained &
Momentary a
NEMA Type 13
Oiltight
Flush Mounting
Voltage
Maximum Horsepower
AC
Single
Phase
AC
Poly-
Phase
DC Type $ Price Type $ Price Type $ Price Type $ Price
115-
200/230
230
460/575
1-1/2
2
2
2
1/4
1/4
AG2 158.00 AW2 428.00 AG2S2 158.00 AF2 131.00
115-
200/230
230
460/575
1-1/2
3
5
5
7-1/2
2
2
BG1 428.00 BW1 590.00 — ———
File
CCN
E42243
NLRV
File
Class
LR25490
3211-05
Table 17.45: How to Order
To Order Specify: Catalog Number
Class Number
Type Number
Class Type
2601 AG2
Type AG2
3.38
86
5.20
132
3.19
81
3.70
94
.20
5
2.38
60
2.87
73
2.77
70
3.81
97
5.58
142
(4) .17 Mounting Holes
Type AF2 Types AW and BW
(2) 1/2" NPT
Pipe Thread
.60
15
1.82
46
5.50
140
6.89
175
3.20
81
4.00
5.18
2.68
3.26
5.38
6.62
dimensions (inches) =
4.61
4.86
AG/AH
BG
(2) K.O. For 1/ 2" Conduits
2.91
3.53
Types AG, BG
Dimensions: in.
mm
Type AW2
CP1 Discount
Schedule
www.schneider-electric.us
17-18 © 2012 Schneider Electric
All Rights Reserved
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Electromechanical
Reduced Voltage Starters
Description of All Types
Class 8600 / Refer to Catalog 8600CT9601
A squirrel cage motor draws high starting current (inrush) and produces high starting torque when started at full voltage.
While these values differ for different motor designs, for a typical NEMA design B motor, the inrush will be approximately
600% of the motor full load amperage (FLA) rating, and the starting torque will be approximately 150% of full load torque at
full voltage. High current inrush and starting torque can cause problems in the electrical and mechanical systems, or may
even damage the materials being processed.
When a motor is started at reduced voltage, the current at the motor terminals is reduced in direct proportion to the voltage
reduction, while the torque is reduced by the square of the voltage reduction. If the “typical” NEMA B motor is started at 70%
of line voltage, the starting current would be 70% of the full voltage value (that is, 0.70 x 600% = 420% FLA). The torque
would then be (0.70)2 or 49% of the normal starting torque (that is, 0.49 x 150% = 74% full load torque). Therefore, reduced
voltage starting provides an effective means of reducing both inrush current and starting torque.
If the motor has a high inertia or if the motor rating is marginal for the applied load, reducing the starting torque may prevent
the motor from reaching full speed before the thermal overload relays trip. Applications that require high starting torque
should be reviewed to determine if reduced voltage starting is suitable.
Square D™ offers several types of electromechanical as well as solid-state reduced voltage starters that provide different
starting characteristics. The following describes the 8600 series of reduced voltage starters.
Class 8606—Autotransformer Starter: Autotransformer starters provide reduced voltage to the motor terminals
during starting through the use of a tapped, three phase autotransformer. Taps on the autotransformer allow for
selection of the motor with 50%, 65%, or 80% of line voltage values supplying 50%, 65%, or 80% of the current inrush
seen during a full voltage start. The resulting starting torque will be 25%, 42%, or 64% of full voltage values, as will be
the current draw on the line. Thus, the autotransformer provides the maximum torque with minimum line current.
Class 8630—Wye-Delta Starter: Wye-delta starters can only be used on wye-delta motors which have six leads that
allow for motor winding to be connected in either a wye or delta configuration. During start up, the windings are
connected in the wye, resulting in 58% of line voltage applied across two windings. This reduces both inrush and
starting torque to 33% of the delta connected values. After a set time delay, the motor leads are switched to the delta
connection. The wye-delta starter is available in both open and closed transition configurations. Closed transition
starters are supplied with an additional contactor and resistor bank used to keep the motor windings energized for a
few cycles until the transition from wye to delta is complete.
Class 8640—Part Winding Starter: Part winding starters can be used only with part winding motors. During a part winding
start, only one winding is energized, reducing the inrush current to 60–70% (depending on the motor design) and starting
torque to 50% of normal starting values with both windings energized. Most (but not all) dual voltage 230/460 volt motors are
suitable for part winding starts at 230 volts.
1. Specify the Class Number and the Type Number.
2. If all coils are at the line voltage, and not Sizes 6 or 7, select the voltage code from Table 17.47 (Sizes 6 and 7 are supplied with a
fused transformer with 120 Vac as standard).
3. If the coils are at a different voltage than line supply, or Size 6 or 7, select a voltage code from Table 17.48 and also select a Form
code from Table 17.49 (note that a Form code may be used with any voltage code, except as noted).
Table 17.46: Starter Characteristics
Characteristic Full Voltage Autotransformer, Class 8606 Wye-Delta Class, 8630 Part Winding, Class 8640 Solid-State ATS46
Voltage at Motor 100% 50% / 65% / 80% (tap setting) 100% 100% Ramped Up
Line Current (% Full Load Current) 600% 150% / 250% / 380% 200% 390% 150% to 700% (adjustable)
Starting Torque (% Rated Torque) 150% 40% / 60% / 100% 50% 70% 0% to 100% (adjustable)
Start Time (Factory Setting) 6–7 seconds 10 seconds / 15 seconds
(open/closed transition)
1–1.5 seconds 10 seconds
(adjustable 1–60 seconds)
Advantages Simple
Economical
High Starting Torque
High torque/amperage
High inertial loads
Flexibility
High inertial loads
Long acceleration loads
Good torque/amperage
Simple
Small size
Greatest flexibility
Smooth ramp
Solid-state overload relay
Diagnostics
Disadvantages Abrupt starts
Large current inrush
Large size Low torque
No flexibility
Not suitable for:
High inertial loads
Frequent starting
SCR heat dissipation
Ambient limitations
Motor Standard Standard Special Special Standard
bSee Table 17.50 for sizing of 380 V starters.
c24 V coils are not available on Sizes 4–7.
Table 17.47: Line Voltage Codes
Line Control Code
208
240
380
480
600
208
240
380
480
600
V08
V03
V05
V06
V07
Table 17.48: Coil Voltage Codes
Line Control Code
208
240
240
480
480
480
600
380
other
120
24
120
24
120
240
120
110/50
specify
V84
V82
V80
V83
V81
V87
V86
V95
V99
Table 17.49: Form Codes
Form Description Form Code
Fused CPT for timing relay only F4T
Fused CPT for all coils F4T40
Separate control of timing relay only S
Separate control for all coils Y195
Table 17.50: 380 Vac, 50 Hz Starters, Maxiumum Horsepower Rating
Autotransformer, Class 8606 Wye-Delta, Class 8630 Part Winding, Class 8640
Max. hp NEMA Size Max. hp NEMA Size Max. hp NEMA Size
25
50
75
150
300
2
3
4
5
6
15
40
75
150
250
500
1YD
2YD
3YD
4YD
5YD
6YD
15
40
75
125
250
500
1PW
2PW
3PW
4PW
5PW
6PW
Table 17.51: Coil Voltages
Hz Vol tage Code Voltag e Code Voltage Code Volt ag e Code
60
50
120
110 V02 240
220 V03 480
440 V06 600
550 V07
Reduced Voltage
Starting of Squirrel
Cage Motors
Electromechanical
Reduced Voltage
Starters
How to Order
Note: Tables 17.47 and 17.48 are
for 60 Hz; see Table 17.51
for 50 Hz codes.
380 Vac, 50 Hz
Starters The Class 8600 starters are available for 380 Vac,
50 Hz applications. Table 17.50 provides maximum
horsepower ratings. To determine the Type Number,
select the second digit based on NEMA size. Select the
fifth digit based on the horsepower requirement. Specify
V05 voltage code. List prices for the same NEMA size
starter apply.
The starters in this section can also be operated at
50 Hz at the coil voltages listed in Table 17.51.
For additional coil voltage availability, contact the
Customer Care Center (CCC) at 1-888-778-2733.
50 Hz Control
Voltage
www.schneider-electric.us
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
© 2012 Schneider Electric
All Rights Reserved 17-19
Electromechanical
Reduced Voltage Starters
Autotransformer Starters
Class 8606 / Refer to Catalog 8600CT9601
NOTE: Prices shown do not include thermal units. Devices require 3 thermal units
(Sizes 00–6). Standard trip thermal units are $21.50 each. See Digest 176
page 16-116 for selection information.
eForms need to be specified only if any of the coils are at a different voltage than line supply (V8•).
See page 17-18 for a fuller explanation of how to order; this page also provides the necessary
coil voltage and Form codes as well as codes for 380 V starters and 50 Hz applications.
Table 17.52: 3-Pole Polyphase, 600 Vac Maximum, 50–60 Hz
Motor
Vol tage
(Starter
Voltage )
Max.
HP
NEMA
Size
NEMA Type 1
General Purpose
Enclosure
NEMA Type 4a
Watertight and
Dusttight Enclosure
NEMA Type 12/3Rd
Dusttight & Driptight
Industrial Use Enclosure
Open Type O.E.M. Kit c
Typeb$ Price Typeb$ Price Typeb$ Price Typeb$ Price Typeb$ Price
200
(208)
10 2 SDG1C 8076.00 SDW1C 12491.00 SDA1C 10641.00 SDO1C 7734.00 SDK1C 6786.00
15
20
25
3
SEG1D
SEG1E
SEG1F
9500.00
SEW1D
SEW1E
SEW1F
13914.00
SEA1D
SEA1E
SEA1F
13707.00
SEO1D
SEO1E
SEO1F
8418.00
SEK1D
SEK1E
SEK1F
7493.00
30
40 4SFG1G
SFG1H 18417.00 SFW1G
SFW1H 26535.00 SFA1G
SFA1H 21834.00 SFO1G
SFO1H 16848.00 SFK1G
SFK1H 13181.00
50
75 5SGG1J
SGG1L 30330.00 SGW1J
SGW1L 38448.00 SGA1J
SGA1L 34176.00 SGO1J
SGO1L 27167.00 SGK1J
SGK1L 23223.00
100
125
150
6
SHG1M
SHG1N
SHG1P
56507.00
SHW1M
SHW1N
SHW1P
67190.00
SHA1M
SHA1N
SHA1P
61848.00
SHO1M
SHO1N
SHO1P
51438.00
SHK1M
SHK1N
SHK1P
41481.00
230
(240)
10
15 2SDG1C
SDG1D 8076.00 SDW1C
SDW1D 12491.00 SDA1C
SDA1D 10641.00 SDO1C
SDO1D 7734.00 SDK1C
SDK1D 6786.00
20
25
30
3
SEG1E
SEG1F
SEG1G
9500.00
SEW1E
SEW1F
SEW1G
13914.00
SEA1E
SEA1F
SEA1G
12207.00
SEO1E
SEO1F
SEO1G
8418.00
SEK1E
SEK1F
SEK1G
7493.00
40
50 4SFG1H
SFG1J 18417.00 SFW1H
SFW1J 26535.00 SFA1H
SFA1J 21834.00 SFO1H
SFO1J 16848.00 SFK1H
SFK1J 13181.00
75
100 5SGG1L
SGG1M 30330.00 SGW1L
SGW1M 38448.00 SGA1L
SGA1M 34176.00 SGO1L
SGO1M 27167.00 SGK1L
SGK1M 23223.00
125
150
200
6
SHG1N
SHG1P
SHG1Q
56507.00
SHW1N
SHW1P
SHW1Q
67190.00
SHA1N
SHA1P
SHA1Q
61848.00
SHO1N
SHO1P
SHO1Q
51438.00
SHK1N
SHK1P
SHK1Q
41481.00
250
300 7SJG1R
SJG1S 96786.00 SJW1R
SJW1S 107468.00 SJA1R
SJA1S 102126.00 ——— —
460
(480)
/
575
(600)
10
15
20
25
2
SDG1C
SDG1D
SDG1E
SDG1F
8076.00
SDW1C
SDW1D
SDW1E
SDW1F
12491.00
SDA1C
SDA1D
SDA1E
SDA1F
10641.00
SDO1C
SDO1D
SDO1E
SDO1F
7734.00
SDK1C
SDK1D
SDK1E
SDK1F
6786.00
30
40
50
3
SEG1G
SEG1H
SEG1J
9500.00
SEW1G
SEW1H
SEW1J
13914.00
SEA1G
SEA1H
SEA1J
12207.00
SEO1G
SEO1H
SEO1J
8418.00
SEK1G
SEK1H
SEK1J
7493.00
60
75
100
4
SFG1K
SFG1L
SFG1M
18417.00
SFW1K
SFW1L
SFW1M
26535.00
SFA1K
SFA1L
SFA1M
21834.00
SFO1K
SFO1L
SFO1M
16848.00
SFK1K
SFK1L
SFK1M
13181.00
125
150
200
5
SGG1N
SGG1P
SGG1Q
30330.00
SGW1N
SGW1P
SGW1Q
38448.00
SGA1N
SGA1P
SGA1Q
34176.00
SGO1N
SGO1P
SGO1Q
27167.00
SGK1N
SGK1P
SGK1Q
23223.00
250
300
400
6
SHG1R
SHG1S
SHG1T
56507.00
SHW1R
SHW1S
SHW1T
67190.00
SHA1R
SHA1S
SHA1T
61848.00
SHO1R
SHO1S
SHO1T
51438.00
SHK1R
SHK1S
SHK1T
41481.00
500
600 7SJG1U
SJG1W 96786.00 SJW1U
SJW1W 107468.00 SJA1U
SJA1W 102126.00 SJO1W 88250.00 ——
aNEMA Type 4 enclosures are painted sheet steel. Where required, stainless steel enclosures are available at extra cost.Specify as Form G17. See “Modifications & Forms” for price adder.
bBoth line and control voltage must be specified to order this product. See page 17-18 for the necessary codes and instructions for ordering.
cNo factory modifications (Forms) are available with O.E.M. Kit.
dNEMA Type 12 enclosures can be field modified for outdoor non-corrosive and non-service entrance rated applications.
Note: Class 8606 starters are supplied with a NEMA style medium duty autotransformer.
Medium duty service includes applications to motors which drive loads such as fans, pumps, compressors, and line shafts.
NEMA Sizes 2–5: Autotransformer is rated for fifteen 15-second starts per hour.
NEMA Sizes 6–7: Autotransformer is rated for three 30-second starts per hour.
Contact the Customer Care Center (CCC) at 1-888-778-2733 for applications which require frequent starting or jogging, or have extremely high inertia.
Table 17.53: How to Order
To Order Specify: Catalog Number
Class Number
Type Number
Voltage Code
Form(s)e
Class Type Voltage Code Form(s)
8606 SFG1M V81 S
Description: 100 hp, 480 V line, 120 V separate control, 60 Hz
ROL
L2
L3
L1
T1
OL T2
2S 1S
1S
R
R
2S
OL T3
TR
1S
2S
Motor
2S
10 0
80
65
50
0
10 0
80
65
50
0
R
1S
2S
TR
TR 1S
R
OL
To
Separate
Control
TR
1Stop Start
23
2 Wire Control
Device (If used)
Typical Autotransformer Starter
Sizes 2–5
Separate Control (Form S)
CP1 Discount
Schedule
www.schneider-electric.us
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
17-20 © 2012 Schneider Electric
All Rights Reserved
Electromechanical
Reduced Voltage Starters
Wye-Delta Starters (Open Transition)
Class 8630 / Refer to Catalog 8600CT9601
NOTE: Prices shown do not include thermal units. Devices require 3 thermal units
(Sizes 00–6). Standard trip thermal units are $21.50 each. See Digest 176 page
16-116 for selection information.
eForms need to be specified only if any of the coils are at a different voltage than line supply (V8•).
See page 17-18 for a fuller explanation of how to order; this page also provides the necessary
coil voltage and Form codes as well as codes for 380 V starters and 50 Hz applications.
Refer to page 17-32 for other factory modifications (Forms).
Table 17.54: 3-Pole Polyphase, 600 Vac Maximum, 50–60 Hz
Motor
Voltage
(Starter
Voltage)
Max.
HP
NEMA
Size
NEMA Type 1
General Purpose
Enclosure
NEMA Type 4a
Watertight and
Dusttight Enclosure
(Stainless Steel 1YD-4YD)
NEMA Type 12/3Rd
Dusttight & Driptight
Industrial Use Enclosure
Open Type O.E.M. Kit c
Typeb$ Price Typeb$ Price Typeb$ Price Typeb$ Price Typeb$ Price
200
(208)
10 1YD SCG1C 4892.00 SCW1C 6602.00 SCA1C 6317.00 SCO1C 4806.00 ——
15
20 2YD SDG1D
SDG1E 5790.00 SDW1D
SDW1E 7713.00 SDA1D
SDA1E 7569.00 SDO1D
SDO1E 5562.00 ——
25
30
40
3YD
SEG1F
SEG1G
SEG1H
8424.00
SEW1F
SEW1G
SEW1H
11204.00
SEA1F
SEA1G
SEA1H
10562.00
SEO1F
SEO1G
SEO1H
7542.00
SEK1F
SEK1G
SEK1H
6596.00
50
60 4YD SFG1J
SFG1K 17568.00 SFW1J
SFW1K 21941.00 SFA1J
SFA1K 20417.00 SFO1J
SFO1K 15987.00 SFK1J
SFK1K 9300.00
75
100
125
150
5YD
SGG1L
SGG1M
SGG1N
SGG1P
31584.00
SGW1L
SGW1M
SGW1N
SGW1P
39702.00
SGA1L
SGA1M
SGA1N
SGA1P
35429.00
SGO1L
SGO1M
SGO1N
SGO1P
28422.00
SGK1L
SGK1M
SGK1N
SGK1P
18530.00
200
250
300
6YD
SHG1Q
SHG1R
SHG1S
67589.00
SHW1Q
SHW1R
SHW1S
78272.00
SHA1Q
SHA1R
SHA1S
72930.00
SHO1Q
SHO1R
SHO1S
62519.00
SHK1Q
SHK1R
SHK1S
39347.00
230
(240)
10 1YD SCG1C 4892.00 SCW1C 6602.00 SCA1C 6317.00 SCO1C 4806.00 ——
15
20
25
2YD
SDG1D
SDG1E
SDG1F
5790.00
SDW1D
SDW1E
SDW1F
7713.00
SDA1D
SDA1E
SDA1F
7569.00
SDO1D
SDO1E
SDO1F
5562.00 ——
30
40
50
3YD
SEG1G
SEG1H
SEG1J
8424.00
SEW1G
SEW1H
SEW1J
11204.00
SEA1G
SEA1H
SEA1J
10562.00
SEO1G
SEO1H
SEO1J
7542.00
SEK1G
SEK1H
SEK1J
6596.00
60
75 4YD SFG1K
SFG1L 17568.00 SFW1K
SFW1L 21941.00 SFA1K
SFA1L 20417.00 SFO1K
SFO1L 15987.00 SFK1K
SFK1L 9300.00
100
125
150
5YD
SGG1M
SGG1N
SGG1P
31584.00
SGW1M
SGW1N
SGW1P
39702.00
SGA1M
SGA1N
SGA1P
35429.00
SGO1M
SGO1N
SGO1P
28422.00
SGK1M
SGK1N
SGK1P
18530.00
200
250
300
6YD
SHG1Q
SHG1R
SHG1S
67589.00
SHW1Q
SHW1R
SHW1S
78272.00
SHA1Q
SHA1R
SHA1S
72930.00
SHO1Q
SHO1R
SHO1S
62519.00
SHK1Q
SHK1R
SHK1S
39347.00
400
500 7YD SJG1T
SJG1U 91160.00 SJW1T
SJW1U 101843.00 SJA1T
SJA1U 96501.00 SJO1T
SJO1U 86090.00 ——
460
(480)
/
575
(600)
10
15 1YD SCG1C
SCG1D 4892.00 SCW1C
SCW1D 6602.00 SCA1C
SCA1D 6317.00 SCO1C
SCO1D 4806.00 ——
20
25
30
40
2YD
SDG1E
SDG1F
SDG1G
SDG1H
5790.00
SDW1E
SDW1F
SDW1G
SDW1H
7713.00
SDA1E
SDA1F
SDA1G
SDA1H
7569.00
SDO1E
SDO1F
SDO1G
SDO1H
5562.00 ——
50
60
75
3YD
SEG1J
SEG1K
SEG1L
8424.00
SEW1J
SEW1K
SEW1L
11204.00
SEA1J
SEA1K
SEA1L
10562.00
SEO1J
SEO1K
SEO1L
7542.00
SEK1J
SEK1K
SEK1L
6596.00
100
125
150
4YD
SFG1M
SFG1N
SFG1P
17568.00
SFW1M
SFW1N
SFW1P
21941.00
SFA1M
SFA1N
SFA1P
20417.00
SFO1M
SFO1N
SFO1P
15987.00
SFK1M
SFK1N
SFK1P
9300.00
200
250
300
5YD
SGG1Q
SGG1R
SGG1S
31584.00
SGW1Q
SGW1R
SGW1S
39702.00
SGA1Q
SGA1R
SGA1S
35429.00
SGO1Q
SGO1R
SGO1S
28422.00
SGK1Q
SGK1R
SGK1S
18530.00
400
500
600
6YD
SHG1T
SHG1U
SHG1W
67589.00
SHW1T
SHW1U
SHW1W
78272.00
SHA1T
SHA1U
SHA1W
72930.00
SHO1T
SHO1U
SHO1W
62519.00
SHK1T
SHK1U
SHK1W
39347.00
800
1000 7YD SJG1Y
SJG1Z 91160.00 SJW1Y
SJW1Z 101843.00 SJA1Y
SJA1Z 96501.00 SJO1Y
SJO1Z 86090.00 ——
aNEMA Type 4 enclosures are painted sheet steel. Where required, stainless steel enclosures are available at extra cost. Specify as Form G17. See page 17-32 for price adder.
bBoth line and control voltage must be specified to order this product. See page 17-18 for the necessary codes and instructions for ordering.
cNo Factory Modifications (Forms) available with O.E.M. Kit.
dNEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See Digest 176 page 16-95 for more information.
Table 17.55: How to Order
To Order Specify: Catalog Number
Class Number
Type Number
Voltage Code
Form(s)e
Class Type Voltage Code Form(s)
8630 SFG1M V06
Description: 100 hp, 480 V line, 480 V common control, 60 Hz
T4 T2
T1 T5
T6 T3
T2
T3
T5
T4
T6
T1
S
S
1M
1M
1M
OL
OL
OL
L1
L2
L3
2M
2M
2M
TR
3
1Stop Start
2
TR
TR
S
1M S
2M
2M
1M
S
TR OL
Motor
2 Wire Control Device (If used)
Typical Wye-Delta Starter Sizes 1–4 (Open Transition)
Common Control (Standard)
CP1 Discount
Schedule
www.schneider-electric.us
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
© 2012 Schneider Electric
All Rights Reserved 17-21
Electromechanical
Reduced Voltage Starters
Wye-Delta Starters (Closed Transition)
Class 8630 / Refer to Catalog 8600CT9601
NOTE: Prices shown do not include thermal units. Devices require 3 thermal units
(Sizes 00–6). Standard trip thermal units are $21.50 each. See Digest 176 page
16-116 for selection information.
eForms need to be specified only if any of the coils are at a different voltage than line supply (V8 •).
See page 17-18 for a fuller explanation of how to order; this page also provides the necessary
coil voltage and Form codes as well as codes for 380 V starters and 50 Hz applications.
Refer to page 17-32 for other factory modifications (Forms).
Table 17.56: 3-Pole Polyphase, 600 Vac Maximum, 50–60 Hz
Motor
Vol tage
(Starter
Voltage )
Max.
HP
NEMA
Size
NEMA Type 1
General Purpose
Enclosure
NEMA Type 4d
Watertight and
Dusttight Enclosure
(Stainless Steel 1YD-4YD)
NEMA Type 12/3Rc
Dusttight & Driptight
Industrial Use Enclosure
Open Type O.E.M. Kit b
Typea$ Price Typea$ Price Typea$ Price Typea$ Price Typea$ Price
200
(208)
10 1YD SCG2C 7470.00 SCW2C 9180.00 SCA2C 8895.00 SCO2C 7385.00 ——
15
20 2YD SDG2D
SDG2E 8454.00 SDW2D
SDW2E 10376.00 SDA2D
SDA2E 10233.00 SDO2D
SDO2E 8226.00 ——
25
30
40
3YD
SEG2F
SEG2G
SEG2H
11672.00
SEW2F
SEW2G
SEW2H
14450.00
SEA2F
SEA2G
SEA2H
13809.00
SEO2F
SEO2G
SEO2H
10790.00
SEK2F
SEK2G
SEK2H
10142.00
50
60 4YD SFG2J
SFG2K 22995.00 SFW2J
SFW2K 27368.00 SFA2J
SFA2K 25844.00 SFO2J
SFO2K 21414.00 SFK2J
SFK2K 13931.00
75
100
125
150
5YD
SGG2L
SGG2M
SGG2N
SGG2P
38363.00
SGW2L
SGW2M
SGW2N
SGW2P
46481.00
SGA2L
SGA2M
SGA2N
SGA2P
42209.00
SGO2L
SGO2M
SGO2N
SGO2P
35202.00
SGK2L
SGK2M
SGK2N
SGK2P
25181.00
200
250
300
6YD
SHG2Q
SHG2R
SHG2S
85022.00
SHW2Q
SHW2R
SHW2S
95702.00
SHA2Q
SHA2R
SHA2S
90363.00
SHO2Q
SHO2R
SHO2S
79950.00
SHK2Q
SHK2R
SHK2S
50319.00
230
(240)
10 1YD SCG2C 7470.00 SCW2C 9180.00 SCA2C 8895.00 SCO2C 7385.00 ——
15
20
25
2YD
SDG2D
SDG2E
SDG2F
8454.00
SDW2D
SDW2E
SDW2F
10376.00
SDA2D
SDA2E
SDA2F
10233.00
SDO2D
SDO2E
SDO2F
8226.00
30
40
50
3YD
SEG2G
SEG2H
SEG2J
11672.00
SEW2G
SEW2H
SEW2J
14450.00
SEA2G
SEA2H
SEA2J
13809.00
SEO2G
SEO2H
SEO2J
10790.00
SEK2G
SEK2H
SEK2J
10142.00
60
75 4YD SFG2K
SFG2L 22995.00 SFW2K
SFW2L 27368.00 SFA2K
SFA2L 25844.00 SFO2K
SFO2L 21414.00 SFK2K
SFK2L 13931.00
100
125
150
5YD
SGG2M
SGG2N
SGG2P
38363.00
SGW2M
SGW2N
SGW2P
46481.00
SGA2M
SGA2N
SGA2P
42209.00
SGO2M
SGO2N
SGO2P
35202.00
SGK2M
SGK2N
SGK2P
25181.00
200
250
300
6YD
SHG2Q
SHG2R
SHG2S
85022.00
SHW2Q
SHW2R
SHW2S
95702.00
SHA2Q
SHA2R
SHA2S
90363.00
SHO2Q
SHO2R
SHO2S
79950.00
SHK2Q
SHK2R
SHK2S
50319.00
400
500 7YD SJG2T
SJG2U 118206.00 SJW2T
SJW2U 128888.00 SJA2T
SJA2U 123548.00 SJO2T
SJO2U 113135.00
460
(480)
/
575
(600)
10
15 1YD SCG2C
SCG2D 7470.00 SCW2C
SCW2D 9180.00 SCA2C
SCA2D 8895.00 SCO2C
SCO2D 7385.00
20
25
30
40
2YD
SDG2E
SDG2F
SDG2G
SDG2H
8454.00
SDW2E
SDW2F
SDW2G
SDW2H
10376.00
SDA2E
SDA2F
SDA2G
SDA2H
10233.00
SDO2E
SDO2F
SDO2G
SDO2H
8226.00
50
60
75
3YD
SEG2J
SEG2K
SEG2L
11672.00
SEW2J
SEW2K
SEW2L
14450.00
SEA2J
SEA2K
SEA2L
13809.00
SEO2J
SEO2K
SEO2L
10790.00
SEK2J
SEK2K
SEK2L
10142.00
100
125
150
4YD
SFG2M
SFG2N
SFG2P
22995.00
SFW2M
SFW2N
SFW2P
27368.00
SFA2M
SFA2N
SFA2P
25844.00
SFO2M
SFO2N
SFO2P
21414.00
SFK2M
SFK2N
SFK2P
13931.00
200
250
300
5YD
SGG2Q
SGG2R
SGG2S
38363.00
SGW2Q
SGW2R
SGW2S
46481.00
SGA2Q
SGA2R
SGA2S
42209.00
SGO2Q
SGO2R
SGO2S
35202.00
SGK2Q
SGK2R
SGK2S
25181.00
400
500
700
6YD
SHG2T
SHG2U
SHG2W
85022.00
SHW2T
SHW2U
SHW2W
95702.00
SHA2T
SHA2U
SHA2W
90363.00
SHO2T
SHO2U
SHO2W
79950.00
SHK2T
SHK2U
SHK2W
50319.00
800
1000 7YD SJG2Y
SJG2Z 118206.00 SJW2Y
SJW2Z 128888.00 SJA2Y
SJA2Z 123548.00 SJO2Y
SJO2Z 113135.00
aBoth line and control voltage must be specified to order this product. See page 17-18 for the necessary codes and instructions for ordering.
bNo Factory Modifications (Forms) available with O.E.M. Kit.
cNEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See Digest 176 page 16-95 for more information.
dNEMA Type 4 enclosures are painted sheet steel. Where required, stainless steel enclosures are available at extra cost. Specify as Form G17. See page 17-32 for price adder.
Table 17.57: How to Order
To Order Specify: Catalog Number
Class Number
Type Number
Voltage Code
Form(s)e
Class Type Voltage Code Form(s)
8630 SFG1M V81 F4T40
Description: 100 hp, 480 V line, 120 V separate control, 60 Hz
OL T1
T1
OL T2
T2
OL T3
T3
T6 T6
T4
T4
T5
T5
1M
2S
2S
2S
1S
1S
1M
1M
2M
2M
2M
L1
L2
L3
OL
2S
1S
1S
1M
2M
TR
TR
TR
(HI) PRI
SEC(X1) (X2)
GND (If used)
PT
TR
1S
2S
1M
2M
23
1Stop Start
2 Wire Control
Device (If used)
R
E
S
R
E
S
R
E
S
Motor
Typical Wye-Delta Starter
Sizes 1–4 (Closed Transition)
Fused Control Transformer (Form F4T40)
CP1 Discount
Schedule
www.schneider-electric.us
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
17-22 © 2012 Schneider Electric
All Rights Reserved
Electromechanical
Reduced Voltage Starters
Part Winding Starters
Class 8640 / Refer to Catalog 8600CT9601
NOTE: Prices shown do not include thermal units. Devices require 6 thermal units
(Sizes 00–6). Standard trip thermal units are $21.50 each. See Digest 176
page 16-116 for selection information.
eForms need to be specified only if any of the coils are at a different voltage than line supply (V8•).
See page 17-18 for a fuller explanation of how to order; this page also provides the necessary
coil voltage and Form codes as well as codes for 380 V starters and 50 Hz applications.
Refer to page 17-32 for other factory modifications (Forms).
Table 17.58: 3-Pole Polyphase—600 Vac Maximum—50–60 Hz
Motor
Vol tage
(Starter
Voltage )
Max.
HP
NEMA
Size
NEMA Type 1
General Purpose
Enclosure
NEMA Type 4a
Watertight and
Dusttight Enclosure
(Stainless Steel 1PW–4PW)
NEMA Type 12/3Rd
Dusttight & Driptight
Industrial Use Enclosure
Open Type O.E.M. Kit c
Typeb$ Price Typeb$ Price Typeb$ Price Typeb$ Price Typeb$ Price
200
(208)
10 1PW SCG1C 3119.00 SCW1C 4829.00 SCA1C 4544.00 SCO1C 3033.00 ——
15
20 2PW SDG1D
SDG1E 4445.00 SDW1D
SDW1E 6368.00 SDA1D
SDA1E 6224.00 SDO1D
SDO1E 4217.00 SDK1D
SDK1E 2685.00
25
30
40
3PW
SEG1F
SEG1G
SEG1H
6267.00
SEW1F
SEW1G
SEW1H
9045.00
SEA1F
SEA1G
SEA1H
8405.00
SEO1F
SEO1G
SEO1H
5868.00
SEK1F
SEK1G
SEK1H
4359.00
50
60
75
4PW
SFG1J
SFG1K
SFG1L
13404.00
SFW1J
SFW1K
SFW1L
17775.00
SFA1J
SFA1K
SFA1L
16253.00
SFO1J
SFO1K
SFO1L
12662.00
SFK1J
SFK1K
SFK1L
8217.00
100
125
150
5PW
SGG1M
SGG1N
SGG1P
28071.00
SGW1M
SGW1N
SGW1P
36192.00
SGA1M
SGA1N
SGA1P
31919.00
SGO1M
SGO1N
SGO1P
26505.00
SGK1M
SGK1N
SGK1P
18621.00
230
(240)
10 1PW SCG1C 3119.00 SCW1C 4829.00 SCA1C 4544.00 SCO1C 3033.00 ——
15
20
25
2PW
SDG1D
SDG1E
SDG1F
4445.00
SDW1D
SDW1E
SDW1F
6368.00
SDA1D
SDA1E
SDA1F
6224.00
SDO1D
SDO1E
SDO1F
4217.00
SDK1D
SDK1E
SDK1F
2685.00
30
40
50
3PW
SEG1G
SEG1H
SEG1J
6267.00
SEW1G
SEW1H
SEW1J
9045.00
SEA1G
SEA1H
SEA1J
8405.00
SEO1G
SEO1H
SEO1J
5868.00
SEK1G
SEK1H
SEK1J
4359.00
60
75 4PW SFG1K
SFG1L 13404.00 SFW1K
SFW1L 17775.00 SFA1K
SFA1L 16253.00 SFO1K
SFO1L 12662.00 SFK1K
SFK1L 8217.00
100
125
150
5PW
SGG1M
SGG1N
SGG1P
28071.00
SGW1M
SGW1N
SGW1P
36192.00
SGA1M
SGA1N
SGA1P
31919.00
SGO1M
SGO1N
SGO1P
26505.00
SGK1M
SGK1N
SGK1P
18621.00
200
250
300
6PW
SHG1Q
SHG1R
SHG1S
58694.00
SHW1Q
SHW1R
SHW1S
67338.00
SHA1Q
SHA1R
SHA1S
65816.00
SHO1Q
SHO1R
SHO1S
53622.00 ——
400 7PW SJG1T 89672.00 SJW1T 98865.00 SJA1T 98217.00 SJO1T 80699.00 ——
460
(480)
/
575
(600)
10
15 1PW SCG1C
SCG1D 3119.00 SCW1C
SCW1D 4829.00 SCA1C
SCA1D 4544.00 SCO1C
SCO1D 3033.00
20
25
30
40
2PW
SDG1E
SDG1F
SDG1G
SDG1H
4445.00
SDW1E
SDW1F
SDW1G
SDW1H
6368.00
SDA1E
SDA1F
SDA1G
SDA1H
6224.00
SDO1E
SDO1F
SDO1G
SDO1H
4217.00
SDK1E
SDK1F
SDK1G
SDK1H
2685.00
50
60
75
3PW
SEG1J
SEG1K
SEG1L
6267.00
SEW1J
SEW1K
SEW1L
9045.00
SEA1J
SEA1K
SEA1L
8405.00
SEO1J
SEO1K
SEO1L
5868.00
SEK1J
SEK1K
SEK1L
4359.00
100
125
150
4PW
SFG1M
SFG1N
SFG1P
13404.00
SFW1M
SFW1N
SFW1P
17775.00
SFA1M
SFA1N
SFA1P
16253.00
SFO1M
SFO1N
SFO1P
12662.00
SFK1M
SFK1N
SFK1P
8217.00
200
250
350
5PW
SGG1Q
SGG1R
SGG1S
28071.00
SGW1Q
SGW1R
SGW1S
36192.00
SGA1Q
SGA1R
SGA1S
31919.00
SGO1Q
SGO1R
SGO1S
26505.00
SGK1Q
SGK1R
SGK1S
18621.00
460
(480)
/
575
(600)
400
500
600
6PW
SHG1T
SHG1U
SHG1W
58694.00
SHW1T
SHW1U
SHW1W
67338.00
SHA1T
SHA1U
SHA1W
65816.00
SHO1T
SHO1U
SHO1W
53622.00 ——
700
800 7PW SJG1X
SJG1Y 89672.00 SJW1X
SJW1Y 98865.00 SJA1X
SJA1Y 98217.00 SJO1X
SJO1Y 80699.00
aNEMA Type 4 enclosures are painted sheet steel. Where required, stainless steel enclosures are available at extra cost. Specifiy as Form G17. See page 17-32 for price adder.
bBoth line and control voltage must be specified to order this product. See page 17-18 for the necessary codes and instructions for ordering.
cNo Factory Modifications (Forms) available with O.E.M. Kit.
dNEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications. See Digest 176 page 16-95 for more information.
OL1 OL2
S
S
R
TR
TR
TR
TR
1Stop Start
23
L1
L2
L3
R
R
S
S
S
SOL2
OL1
OL1
OL1
OL2
OL2 A
B
C
D
E
F
To Motor
2 Wire Control
Device (If used)
Typical Part Winding
Sizes 1–4
Common Control (Standard)
Table 17.59: How to Order
To Order Specify: Catalog Number
Class Number
Type Number
Voltage Code
Form(s)e
Class Type Voltage Code Form(s)
8640 SFG1M V06 C
Description: 100 hp, 480 V line, 480 V common control, 60 Hz
CP1 Discount
Schedule
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-23
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Electromechanical
Reduced Voltage Starters
Approximate Dimensions
Class 8606, 8630, 8640 / Refer to Catalog 8600CT9601
Approximate Dimensions—Not for Construction
Note: H = Height, W = Width, D = Depth
aSubtract 8 in. from height for Type 1 or 12 enclosure.
bFree standing enclosure. Combination Starter Form Reference
Circuit Breaker: Y791, Y7911
Nonfusible Disconnect Switch: Y792, Y7910
Fusible Disconnect Switch: Y793-Y799
Refer to page 17-32 for a complete listing of Forms for combination devices.
Class 8606
Autotransformer
Table 17.60: Class 8606—Autotransformer
NEMA
Size Dim. Open
NEMA Type 1 / 12 Enclosure NEMA Type 4 Enclosure
Non-Combo or Combo
with Circuit Breaker
Combo
with Disconnect Switch
Non-Combo or Combo
with Circuit Breaker
Combo
with Disconnect Switch
in. mm in. mm in. mm in. mm in. mm
2
H 43 1092 52 1320 52 1320 52 1320 52 1320
W 22 559 25 635 25 635 25 635 25 635
D 8 203 10 254 10 254 10 254 10 254
3 or 4
H63160070b1778 70b1778 75b1778 75b1778
W 28 711 32 813 32 813 32 813 32 813
D 9 229 16 406 16 406 16 406 16 406
5
H63160070b1778 90b2286 75b1778 95b 2413
W 28 711 32 813 36 914 32 813 36 914
D 9 229 16 406 16 406 16 406 16 406
6
H56142290b2286 90b2286 98b2489 98b2489
W 30 762 34 864 64 1626 34 864 64 1626
D 14 354 20 508 24 610 20 508 24 610
Class 8630
Wye-Delta
Table 17.61: Class 8630—Wye-Delta, Open Transition
NEMA
Size Dim. Open NEMA Type 1 / 12 Enclosure NEMA Type 4 Enclosure
Non-Combo Combo Non-Combo Combo
in. mm in. mm in. mm in. mm in. mm
1YD
or
2YD
H 21 553 25 635 25 635 25 635
W 21 553 23 584 23 584 23 584
D 7 178 8 203 8 203 8 203
3YD
or
4YD
H 42 1067 48 1219 49 1245 48 1219 49 1245
W 25 635 28 712 30 762 28 712 30 762
D 7 178 8 203 11 279 8 203 11 279
5YD
or
6YD
H62157690b2286 90b2286 98b2489 98b2489
W 29 737 36 914 36 914 36 914 36 914
D 10 254 16 406 16 406 16 406 16 406
Table 17.62: Class 8630—Wye-Delta, Closed Transition
NEMA
Size Dim. Open NEMA Type 1 / 12 Enclosure NEMA Type 4 Enclosure
Non-Combo Combo Non-Combo Combo
in. mm in. mm in. mm in. mm in. mm
1YD
or
2YD
H 21 553 25 635 25 635 25 635
W 21 553 23 584 23 584 23 584
D 14 354 16 406 16 406 16 406
3YD
or
4YD
H 42 1067 48 1219 49 1245 48 1219 49 1245
W 25 635 28 712 30 762 28 712 30 762
D 14 354 16 406 18 457 16 406 18 457
5YD
or
6YD
H80203290b2286 90b2286 98b2489 98b2489
W 30 762 36 914 36 914 36 914 36 914
D 12 305 16 406 16 406 16 406 16 406
Class 8640
Part Winding
Table 17.63: Class 8640—Part Winding
NEMA
Size Dim. Open
Enclosed—NEMA Type 1 / 4 / 12
Non-Combo Combo with Circuit Breaker Combo with Disconnect
Switch
in. mm in. mm in. mm in. mm
1PW
or
2PW
H 21 553 25 635 34 853 25 635
W 21 553 23 584 19 483 23 584
D 6 152 8 203 11 279 8 203
3PW
H 42 1067 48 1219 44 1118 52 1321
W 26 660 28 712 30 762 25 635
D 7 178 8 203 12 305 11 279
4PW
H 42 1067 48 1219 44 1118 78b1981
W 26 660 28 712 30 762 32 813
D 7 178 8 203 12 305 16 406
5PW
H 35 889 44 1118 78ba 1981 78ba 1981
W 22 559 24 610 36 914 36 914
D 10 254 12 305 16 406 16 406
6PW
H 49 1245 64 1626 — 90b2286
W 24 610 28 712 — 64 1626
D 11 279 16 406 — 24 406
www.schneider-electric.us
17-24 © 2012 Schneider Electric
All Rights Reserved
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Multispeed Magnetic
Starters
Application Data
Class 8810 / Refer to Catalog 8502CT9701
Multispeed motors are available in two basic versions:
1) separate winding, and 2) consequent pole. A separate
winding motor has a winding for each speed while a
consequent pole motor has a winding for every two speeds
(three-speed motors have two windings). The motor
connections (and thus the types of controllers) for two
speed starters are exemplified by the schematic diagrams
shown below. Note that consequent pole two-speed
controllers involve a 5-pole and a 3-pole starter, while
separate winding controllers have two 3-pole starters.
Verify the type of motor before ordering. Field
modification of starters to match the motor may not
be possible.
Separate winding motors are usually chosen when
flexibility is important, since the speeds of a consequent
pole motor are usually limited to a 2/1 ratio; a broad range
of speeds can be obtained on a separate winding motor.
Both separate winding and consequent pole motors are
available in three types: 1) constant horsepower,
2) constant torque, and 3) variable torque. Table 17.64
shows typical applications for these different types of
motors.
NOTE: For detailed information involving the technical
aspects of flexibility of the starters used in the
multispeed controllers, see Classes 8702,
8736, and 8810 application data.
Additional Features—Special Relays for
Non-Reversing and Reversing Multispeed
Starters
General. Some applications require special relays to
control the speed change and/or starting of the motor.
The descriptions that follow cover the four common relay
schemes for these applications.
Form R1 Compelling Relay. This relay requires the
motor to be started at low speed before any higher speed
can be selected. This arrangement ensures that the motor
will always start the load at low speed. The stop button
must be pressed before it is possible to change from a
higher to a lower speed. (Not available with Form R2.)
Form R2 Accelerating Relay/Timer. With Form R2
accelerating relays, the ultimate speed is determined by
the button which is pressed, but the starter will start the
motor at low speed and automatically accelerate it through
successive steps until the selected speed is reached.
Definite time intervals must elapse between each speed
change. Individual adjustable timing relays are provided
for each interval.
The stop button must be pressed before it is possible to
change from a higher to a lower speed.
(Not available with Form R1.)
Form R3 Decelerating Relay/Timer. This is similar in
action to Form R2 accelerating relays, except that they
function to prevent immediate transfer from a higher to a
lower speed. A definite time interval, preset on the timer,
must elapse between each speed change.
Form R10 Antiplugging Relays/Timers. This Form
imposes a time delay when transferring from the forward
to the reverse direction or reverse to forward, for
reversing multispeed starters. This provides up to a
60 second delay in the transfer of the direction of the
motor, and can help prevent damage which could result
from plugging.
Form Y81 (Low Speed) Overload Relay Modification.
For NEMA size 3 and 4, when the low speed full load
current does not appear on the appropriate thermal unit
selection tables, include Form Y81 (low speed) (no charge
for this Form). This Form modifies the overload relay block
to accept Type B thermal units. For assistance on thermal
unit selection, contact the Customer Care Center (CCC) at
1-888-778-2733.
Table 17.64: Typical Applications
Constant HP Constant Torque Variable Torque
A. Spindles A. Conveyors A. Fans
B. Cutting Tools B. Mills B. Centrifugal Pumps
1. Lathes C. Dough Mixers
2. Saws D. Reciprocating Pumps
Table 17.65: Typical Schematic Diagrams
STOP HIGH 4LOW 5H
HIGH
L
2
H
3L
LL
LLL
L1
L2
L3
LOL OL
H
H
H
H
OL OL OL OL OL OL
T1 T2 T3 T6 T4 T5
1
2-Speed
Consequent Pole
Constant Horsepower
NEMA Size 0–4
Sizes 5, 6, & 7 Use Special Circuitry
STOP HIGH 4LOW 5H
HIGH
L
2
H
3L
LLL
L1
L2
L3
LOL OL
H
H
H
H
HH
OL OL OL OL OL OL
T1 T2 T3 T6 T4 T5
1
2-Speed
Consequent Pole
Constant or Variable Torque
NEMA Size 0–4
Sizes 5, 6, & 7 Use Special Circuitry
STOP HIGH4
LOW
5H
HIGH
L
2
H
3L
LLL
L1
L2
L3
LOLOL
H
H
H
H
OL OL OL OL OL OL
T1 T2 T3 T11 T12 T13
1
2-Speed
Separate Winding
Constant HP, Constant Torque
and Variable Torque
NEMA Size 0–4
Sizes 5, 6, & 7 Use Special Circuitry
Table 17.66: Special Pilot Lighting
STOP HIGH 4LOW 5H
HIGH
L
2
H
L
H
3L
L OL OL
H
ON
To Power Circuit
1
One pilot light “On”
STOP HIGH 4LOW 5H
HIGH
L
2
H
LH
3L
LOL OL
H
OFF
To Power Circuit
1
One pilot light “Off”
STOP HIGH 4LOW 5H
HIGH
L
2
H
3L
L
L
OL OL
H
H
To Power Circuit
1
Two pilot lights
“L” and “H'”
STOP HIGH 4LOW 5H
HIGH
L
2
H
L
H
3L
LOL OL
H
ON
To Power Circuit
OFF
1
LH
Two pilot lights
“On” and “Off”
STOP HIGH 4LOW 5H
HIGH
L
2
H
3L
L
L
OL OL
H
H
To Power Circuit
OFF
1
HL
Three pilot lights
“L”, “H”, and “Off”
“L”, “H” and “Off”
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-25
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Multispeed Magnetic
Starters
Application Data
Class 8810 / Refer to Catalog 8502CT9701
Multispeed motors are available in two basic versions: 1) consequent pole, and 2) separate winding. A separate
winding motor has a winding for each speed while a consequent pole motor has a winding for every two speeds
(three-speed motors have two windings).
3-Pole Polyphase, 600 Vac Maximum, 50–60 Hz
Note that the prices shown do not include thermal units. Devices require 6 thermal units (Sizes 0–6). Standard trip
thermal units are $21.50 each. See Digest 176 page 16-116 for selection information.
aThe NEC 1300% maximum setting for instantaneous trip circuit breakers may be inadequate for multispeed motors.
bPrices and type numbers shown for three phase, separate-winding motor starters apply only when motor windings are wye connected.
When motor windings are connected open delta, use the prices shown for three phase consequent pole motor starters.
cVoltage code must be specified to order this product. Refer to standard voltage codes shown on page 17-18.
dNEMA Type 4X hubs are included with each starter at no additional cost.
eNot available in Mag-Gard versions.
fNEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated applications.
See Digest 176 page 16-95 for more information.
Table 17.67: Class 8810—Non-Combination Type
Type of
Motor
NEMA
Size
Maximum Polyphase Horsepower Ratings
NEMA Type 1
General
Purpose
Enclosure
NEMA Type 4 & 4X
Watertight and
Dusttight
Enclosure
(Stainless Steel)
(304)
(Sizes 0—5)
Sheet Steel
(Size 6)
NEMA Type 4Xd
Watertight,
Dusttight
and Corrosion
Resistant
Enclosure
NEMA Type 12/3Rf
Dusttight and
Driptight
Industrial Use
Enclosure
Open Type
Constant
Horsepower
Motors
Constant Torque
or Variable
Torque Motors
200 V 230 V 460–
575 V 200 V 230 V 460
575 V Type $ Price Type $ Price Type $ Price Type $ Price Type $ Price
Single Winding (Consequent Pole) 5-Pole–3-Pole
Constant
HP
0
1
2
3
4
5
6
2
5
7-1/2
20
30
60
100
2
5
10
25
40
75
150
3
7-1/2
20
40
75
150
300
SBG1c
SCG1c
SDG1c
SEG1c
SFG1c
SGG1c
SHG1c
2199.
2370.
4307.
6501.
17352.
34286.
77286.
SBW1c
SCW1c
SDW1c
SEW1c
SFW1c
SGW1c
SHW1c
3567.
3708.
5958.
8837.
22365.
46008.
93308.
SBW51c
SCW51c
SDW51c
4100.
4278.
6557.
SBA1c
SCA1c
SDA1c
SEA1c
SFA1c
SGA1c
SHA1c
2640.
2811.
4932.
7925.
20172.
46008.
83753.
SBO1c
SCO1c
SDO1c
SEO1c
SFO1c
SGO1c
SHO1c
2142.
2285.
4050.
6101.
15786.
31197.
70799.
Constant
To r q u e
or
Variable
To r q u e
0
1
2
3
4
5
6
3
7-1/2
10
25
40
75
150
3
7-1/2
15
30
50
100
200
5
10
25
50
100
200
400
SBG2c
SCG2c
SDG2c
SEG2c
SFG2c
SGG2c
SHG2c
2199.
2370.
4307.
6501.
17352.
34286.
77286.
SBW2c
SCW2c
SDW2c
SEW2c
SFW2c
SGW2c
SHW2c
3567.
3708.
5958.
8837.
22365.
46008.
93308.
SBW52c
SCW52c
SDW52c
4100.
4278.
6557.
SBA2c
SCA2c
SDA2c
SEA2c
SFA2c
SGA2c
SHA2c
2640.
2811.
4932.
7925.
20172.
46008.
83753.
SBO2c
SCO2c
SDO2c
SEO2c
SFO2c
SGO2c
SHO2c
2142.
2285.
4050.
6101.
15786.
31197.
70799.
Two Winding (Separate Winding) 3-Pole–3-Poleb
Constant
HP
b
0
1
2
3
4
5
6
7
2
5
7-1/2
20
30
60
100
2
5
10
25
40
75
150
225
3
7-1/2
20
40
75
150
300
450
SBG3c
SCG3c
SDG3c
SEG3c
SFG3c
SGG3c
SHG3c
SJG3c
1571.
1772.
3167.
4962.
12168.
28718.
58755.
76032.
SBW3c
SCW3c
SDW3c
SEW3c
SFW3c
SGW3c
SHW3c
2939.
3110.
3231.
7412.
17181.
40440.
66090.
SBW53c
SCW53c
SDW53c
3384.
3567.
3564.
SBA3c
SCA3c
SDA3c
SEA3c
SFA3c
SGA3c
SHA3c
SJA3c
2015.
2213.
2529.
6386.
14988.
40440.
65195.
82826.
SBO3c
SCO3c
SDO3c
SEO3c
SFO3c
SGO3c
SHO3c
SJO3c
1515.
1686.
1956.
4590.
11429.
26994.
51848.
69195.
Constant
To r q u e
or
Variable
To r q u e
b
0
1
2
3
4
5
6
7
3
7-1/2
10
25
40
75
150
3
7-1/2
15
30
50
100
200
300
5
10
25
50
100
200
400
600
SBG4c
SCG4c
SDG4c
SEG4c
SFG4c
SGG4c
SHG4c
SJG4c
1571.
1772.
3167.
4962.
12168.
28718.
58755.
76032.
SBW4c
SCW4c
SDW4c
SEW4c
SFW4c
SGW4c
SHW4c
2939.
3110.
3231.
7412.
17181.
40440.
66090.
SBW54c
SCW54c
SDW54c
3384.
3567.
3564.
SBA4c
SCA4c
SDA4c
SEA4c
SFA4c
SGA4c
SHA4c
SJA4c
2015.
2213.
2529.
6386.
14988.
40440.
65195.
82826.
SBO4c
SCO4c
SDO4c
SEO4c
SFO4c
SGO4c
SHO4c
SJO4c
1515.
1686.
1956.
4590.
11429.
26994.
51848.
69195.
Table 17.68: Class 8810—Combination Circuit Breaker Type (Thermal Magnetic Circuit Breakers)ae
Single Winding (Consequent Pole) 5-Pole–3-Pole
Constant
HP
0
1
2
3
4
5
6
2
5
7-1/2
20
30
60
100
2
5
10
25
40
75
150
3
7-1/2
20
40
75
150
300
CBG1c
CCG1c
CDG1c
CEG1c
CFG1c
CGG1c
CHG1c
4206.
4377.
6758.
9162.
22224.
43758.
91229.
CBW1c
CCW1c
CDW1c
CEW1c
CFW1c
CGW1c
CHW1c
6429.
6566.
10089.
13836.
29460.
57816.
68843.
CBW51c
CCW51c
CDW51c
6962.
7140.
10089.
CBA1c
CCA1c
CDA1c
CEA1c
CFA1c
CGA1c
CHA1c
4676.
4867.
7497.
10787.
26753.
56847.
65841.
Constant
To r q u e
or
Variable
To r q u e
0
1
2
3
4
5
6
3
7-1/2
10
25
40
75
150
3
7-1/2
15
30
50
100
200
5
10
25
50
100
200
400
CBG2c
CCG2c
CDG2c
CEG2c
CFG2c
CGG2c
CHG2c
4206.
4377.
6758.
9162.
22224.
43758.
91229.
CBW2c
CCW2c
CDW2c
CEW2c
CFW2c
CGW2c
CHW2c
6429.
6566.
10089.
13836.
29460.
57816.
68843.
CBW52c
CCW52c
CDW52c
6962.
7140.
10089.
CBA2c
CCA2c
CDA2c
CEA2c
CFA2c
CGA2c
CHA2c
4676.
4867.
7497.
10787.
26753.
56847.
65841.
Two Winding (Separate Winding) 3-Pole–3-Poleb
Constant
HP
b
0
1
2
3
4
5
6
7
2
5
7-1/2
20
30
60
100
2
5
10
25
40
75
150
225
3
7-1/2
20
40
75
150
300
450
CBG3c
CCG3c
CDG3c
CEG3c
CFG3c
CGG3c
CHG3c
CJG3c
3581.
3780.
5616.
7626.
17040.
38190.
72629.
95358.
CBW3c
CCW3c
CDW3c
CEW3c
CFW3c
CGW3c
CHW3c
5801.
5972.
8379.
12297.
16182.
52248.
84306.
CBW53c
CCW53c
CDW53c
6251.
6429.
8879.
CBA3c
CCA3c
CDA3c
CEA3c
CFA3c
CGA3c
CHA3c
CJA3c
4050.
4248.
6357.
9248.
14379.
51278.
80199.
103217.
Constant
To r q u e
or
Variable
To r q u e
b
0
1
2
3
4
5
6
7
3
7-1/2
10
25
40
75
150
3
7-1/2
15
30
50
100
200
300
5
10
25
50
100
200
400
600
CBG4c
CCG4c
CDG4c
CEG4c
CFG4c
CGG4c
CHG4c
CJG4c
3581.
3780.
5616.
7626.
17040.
38190.
72629.
95358.
CBW4c
CCW4c
CDW4c
CEW4c
CFW4c
CGW4c
CHW4c
5801.
5972.
8379.
12297.
16182.
52248.
84306.
CBW54c
CCW54c
CDW54c
6251.
6429.
8879.
CBA4c
CCA4c
CDA4c
CEA4c
CFA4c
CGA4c
CHA4c
CJA4c
4050.
4248.
6357.
9248.
14379.
51278.
80199.
103217.
CP1 Discount
Schedule
www.schneider-electric.us
17-26 © 2012 Schneider Electric
All Rights Reserved
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Multispeed Magnetic
Starters
Two-Speed Combination Starters
Class 8810 / Refer to Catalog 8502CT9701
3-Pole Polyphase, 600 Vac Max., 50–60 Hz
Note that the prices shown do not include thermal units.
Devices require 6 thermal units (Sizes 0–6).
Standard trip thermal units are $21.50 each.
See Digest 176 page 16-116 for selection information.
aPrices and type numbers shown for three phase, separate-winding
motor starters apply only when motor windings are wye connected.
When motor windings are connected open delta, use the prices shown
for three phase consequent pole motor starters.
bVoltage code must be specified to order this product. Refer to standard
voltage codes shown below.
cNEMA Type 12 enclosures may be field modified for outdoor
non-corrosive and non-service entrance rated applications. See
Digest 176 page 16-95 for more information.
dWhen separate control is specified, use V8x (see page 32) voltage
codes to specify motor and control voltages.
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17-28
Refer to the following Digest 176 pages for:
Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16-100
Replacement Parts (Class 9998). . . . . . . . . . . . . . . . . . . . . . . . . page 16-105
Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . . . . page 16-109
e24 V coils are not available on Sizes 4–7. On Sizes 00–3, where 24 V
coils are available, Form S (separate control) must be specified (for
example, order as 8810UBG1V01S).
fThese voltage codes must include Form S (supplied at no charge)
(for example, order as 8810UCG1V02S).
Note: For voltage codes used with control transformers, see page 17-32.
Form S (separate control) is used when a separate source of power is
available for the control (coil) voltage. Form S is supplied at no charge.
Table 17.69: Class 8810—Combination Disconnect Switch Type (Class H Fuse Clips)
Type of
Motor
NEMA
Size
Maximum Polyphase Horsepower Ratings
Fuse
Clip
Size
A
NEMA Type 1
General
Purpose
Enclosure
NEMA Type 4 & 4X
Watertight
and Dusttight Enclosure
Stainless Steel (304)
(Sizes 0–5)
Sheet Steel (Size 6 not 4X)
NEMA Type 12/3Rc
Dusttight and
Driptight
Industrial Use
Enclosure
Constant
Horsepower
Motors
Constant Torque
or Variable
Torque Motors
200 V 230 V 460–
575 V 200 V 230 V 460–
575 V Type $ Price Type $ Price Type $ Price
Single Winding (Consequent Pole) 5-Pole–3-Pole
Constant
Horsepower
0 223
None
30d
UBG1b
DBG1b
3537.00
3765.00
UBW1b
DBW1b
5759.00
5988.00
UBA1b
DBA1b
4008.00
4235.00
1 5 5 7-1/2———
None
30d
UCG1b
DCG1b
3708.00
3936.00
UCW1b
DCW1b
5903.00
6129.00
UCA1b
DCA1b
4179.00
4406.00
2 7-1/2 10 20 — — — None
60
UDG1b
DDG1b
6015.00
6129.00
UDW1b
DDW1b
8751.00
8864.00
UDA1b
DDA1b
6758.00
6870.00
3 202540
None
100
UEG1b
DEG1b
8666.00
8837.00
UEW1b
DEW1b
13337.00
13508.00
UEA1b
DEA1b
10287.00
10458.00
4 304075
None
200
UFG1b
DFG1b
19517.00
20970.00
UFW1b
DFW1b
27693.00
25964.00
UFA1b
DFA1b
24987.00
22500.00
5 6075150———
None
400
UGG1b
DGG1b
39644.00
40154.00
UGW1b
DGW1b
35799.00
54212.00
UGA1b
DGA1b
34622.00
52446.00
6 100 150 300 — — — None
600
UHG1b
DHG1b
87789.00
91085.00
UHW1b
DHW1b
99824.00
103121.00
UHA1b
DHA1b
95324.00
98621.00
Constant
To r q u e
or
Variable
To r q u e
0 ——— 3 3 5
None
30d
UBG2b
DBG2b
3537.00
3765.00
UBW2b
DBW2b
5759.00
5988.00
UBA2b
DBA2b
4008.00
4235.00
1 — — — 7-1/2 7-1/2 10 None
30d
UCG2b
DCG2b
3708.00
3936.00
UCW2b
DCW2b
5903.00
6129.00
UCA2b
DCA2b
4179.00
4406.00
2 — — — 10 15 25 None
60
UDG2b
DDG2b
6015.00
6129.00
UDW2b
DDW2b
8751.00
8864.00
UDA2b
DDA2b
6758.00
6870.00
3 — — — 25 30 50 None
100
UEG2b
DEG2b
8666.00
8837.00
UEW2b
DEW2b
13337.00
13508.00
UEA2b
DEA2b
10287.00
10458.00
4 — — — 40 50 100 None
200
UFG2b
DFG2b
19517.00
20970.00
UFW2b
DFW2b
27693.00
25964.00
UFA2b
DFA2b
24987.00
22500.00
5 — — — 75 100 200 None
400
UGG2b
DGG2b
39644.00
40154.00
UGW2b
DGW2b
35799.00
54212.00
UGA2b
DGA2b
34622.00
52446.00
6 150 200 400 None
600
UHG2b
DHG2b
87789.00
91085.00
UHW2b
DHW2b
99824.00
103121.00
UHA2b
DHA2b
95324.00
98621.00
Two Winding (Separate Winding) 3-Pole–3-Pole
Constant
Horsepower
a
0 223
None
30d
UBG3b
DBG3b
2910.00
3140.00
UBW3b
DBW3b
5133.00
5360.00
UBA3b
DBA3b
3380.00
3609.00
1 5 57-1/2———
None
30d
UCG3b
DCG3b
3110.00
3338.00
UCW3b
DCW3b
5304.00
5531.00
UCA3b
DCA3b
3581.00
3807.00
2 7-1/2 10 20 — — — None
60
UDG3b
DDG3b
4877.00
4991.00
UDW3b
DDW3b
7640.00
7754.00
UDA3b
DDA3b
5616.00
5732.00
3 202540
None
100
UEG3b
DEG3b
7127.00
7866.00
UEW3b
DEW3b
11798.00
11969.00
UEA3b
DEA3b
8751.00
9491.00
4 304075
None
200
UFG3b
DFG3b
15159.00
17324.00
UFW3b
DFW3b
22509.00
23021.00
UFA3b
DFA3b
19803.00
21852.00
5 6075150———
None
400
UGG3b
DGG3b
34073.00
34586.00
UGW3b
DGW3b
48131.00
48644.00
UGA3b
DGA3b
50439.00
50952.00
6 100 150 300 — — — None
600
UHG3b
DHG3b
69188.00
72485.00
UHW3b
DHW3b
80868.00
84164.00
UHA3b
DHA3b
76766.00
80063.00
Constant
To r q u e
or
Variable
To r q u e
a
0 ——— 3 3 5
None
30d
UBG4b
DBG4b
2910.00
3140.00
UBW4b
DBW4b
5133.00
5360.00
UBA4b
DBA4b
3380.00
3609.00
1 — — — 7-1/2 7-1/2 10 None
30d
UCG4b
DCG4b
3110.00
3338.00
UCW4b
DCW4b
5304.00
5531.00
UCA4b
DCA4b
3581.00
3807.00
2 10 15 25 None
60
UDG4b
DDG4b
4877.00
4991.00
UDW4b
DDW4b
7640.00
7754.00
UDA4b
DDA4b
5616.00
5732.00
3 — — — 25 30 50 None
100
UEG4b
DEG4b
7127.00
7866.00
UEW4b
DEW4b
11798.00
11969.00
UEA4b
DEA4b
8751.00
9491.00
4 — — — 40 50 100 None
200
UFG4b
DFG4b
15159.00
17324.00
UFW4b
DFW4b
22509.00
23021.00
UFA4b
DFA4b
19803.00
21852.00
5 — — — 75 100 200 None
400
UGG4b
DGG4b
34073.00
34586.00
UGW4b
DGW4b
48131.00
48644.00
UGA4b
DGA4b
50439.00
50952.00
6 150 200 400 None
600
UHG4b
DHG4b
69188.00
72485.00
UHW4b
DHW4b
80868.00
84164.00
UHA4b
DHA4b
76766.00
80063.00
Table 17.70: Coil Voltage Codes
Voltage Code $ Price Adder
60 Hz 50 Hz
24fe
120f
208
240
480
600
Specify
110
220
380
440
550
Specify
V01
V02
V08
V03
V05
V06
V07
V99
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
35.60
CP1 Discount
Schedule
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-27
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Multispeed Magnetic
Starters
Reversing Two-Speed Magnetic Starters
Class 8810 / Refer to Catalog 8502CT9701
3-Pole Polyphase, 600 Vac Max., 50–60 Hz
Note that the prices shown do not include thermal units. Devices require 6 thermal units (Sizes 0–6).
Standard trip thermal units are $21.50 each. See Digest 176 page 16-116 for selection information.
3-Pole Polyphase, 600 Vac Max., 50–60 Hz
Note that the prices shown do not include thermal units. Devices require 6 thermal units (Sizes 0–6). Standard trip
thermal units are $21.50 each. See Digest 176 page 16-116 for selection information.
aPrices and type numbers shown for three phase, separate winding motor starters apply only when motor windings are wye connected. When motor
windings are connected open delta, use the prices shown for consequent pole motor starters.
bSpecify the speed which requires reversing by adding an L (low) or an H (high) after the type number, e.g., a Class 8810 Type SBG21 with reversing in
low only would be ordered as a Class 8810 Type SBG21L.
cVoltage codes must be specified to order this product. Refer to standard voltage codes listed below.
d24 V coils are not available on Sizes 4–7. On Sizes 00–3, where 24 V coils are available,
Form S (separate control) must be specified (for example, order as 8810SCG21V01S).
eThese voltage codes must include Form S (supplied at no charge) (for example, order as 8810SDG21V02S).
fNEMA Type 12 enclosures may be field modified for outdoor non-corrosive and non-service entrance rated
applications. See Digest 176 page 16-95 for more information.
Note: For voltage codes used with control transformers, see page 17-18.
Form S (separate control) is used when a separate source of power is available for the control (coil) voltage.
Form S is supplied at no charge.
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17-28
Refer to the following Digest 176 pages for:
Factory Modifications (Forms) . . . . . . . . . . . . . . . . . . . . . . . page 16-100
Replacement Parts (Class 9998) . . . . . . . . . . . . . . . . . . . . . page 16-105
Type S Accessories (Class 9999) . . . . . . . . . . . . . . . . . . . . . page 16-109
Table 17.71: Class 8810—Reversing
Type of
Motor
NEMA
Size
Maximum Polyphase Ratings Reversing In One Speed Only (Specify High or Low)bReversing In Both Speeds
Constant
Horsepower
Motors
Constant Torque
or Variable
Torque Motors
NEMA Type 1
General
Purpose
Enclosure
NEMA Type 12
Dusttight
and Driptight
Industrial Use
Enclosure
Open
Type
NEMA Type 1
General
Purpose
Enclosure
NEMA Type
12/3Rf
Dusttight
and Driptight
Industrial Use
Enclosure
Open
Type
200 V 230 V 460–
575 V 200 V 230 V 460–
575 V Type $ Price Type $ Price Type $ Price Type $ Price Type $ Price Type $ Price
Single
Winding
Constant
Horsepower
0
1
2
3
4
5
2
5
7-1/2
20
30
60
2
5
10
25
40
75
3
7-1/2
20
40
75
150
SBG21c
SCG21c
SDG21c
SEG21c
SFG21c
SGG21c
3936.
4248.
6984.
10260.
20457.
46449.
SBA21c
SCA21c
SDA21c
SEA21c
SFA21c
SGA21c
5261.
5574.
8522.
13892.
28290.
58172.
SBO21c
SCO21c
SDO21c
SEO21c
SFO21c
SGO21c
3851.
4121.
6501.
9662.
19718.
42164.
SBG31c
SCG31c
SDG31c
SEG31c
SFG31c
SGG31c
4563.
4926.
8522.
13508.
26810.
56946.
SBA31c
SCA31c
SDA31c
SEA31c
SFA31c
SGA31c
6330.
6728.
10517.
17139.
33390.
68679.
SBO31c
SCO31c
SDO31c
SEO31c
SFO31c
SGO31c
4449.
4791.
8010.
11997.
24930.
52659.
Single
Winding
Constant
Torque or
Variable
To r q u e
0
1
2
3
4
5
3
7-1/2
10
25
40
75
3
7-1/2
15
30
50
100
5
10
25
50
100
200
SBG22c
SCG22c
SDG22c
SEG22c
SFG22c
SGG22c
3936.
4248.
6984.
10260.
20457.
46449.
SBA22c
SCA22c
SDA22c
SEA22c
SFA22c
SGA22c
5261.
5574.
8522.
13892.
28290.
58172.
SBO22c
SCO22c
SDO22c
SEO22c
SFO22c
SGO22c
3851.
4121.
6501.
9662.
19718.
42164.
SBG32c
SCG32c
SDG32c
SEG32c
SFG32c
SGG32c
4563.
4926.
8522.
13508.
26810.
56946.
SBA32c
SCA32c
SDA32c
SEA32c
SFA32c
SGA32c
6330.
6728.
10517.
17139.
33390.
68679.
SBO32c
SCO32c
SDO32c
SEO32c
SFO32c
SGO32c
4449.
4791.
8010.
11997.
24930.
52659.
Two Winding
Constanta
Horsepower
0
1
2
3
4
5
2
5
7-1/2
20
30
60
2
5
10
25
40
75
3
7-1/2
20
40
75
150
SBG23c
SCG23c
SDG23c
SEG23c
SFG23c
SGG23c
3252.
3452.
5817.
9005.
15929.
37335.
SBA23c
SCA23c
SDA23c
SEA23c
SFA23c
SGA23c
4577.
4778.
7353.
12639.
22338.
49058.
SBO23c
SCO23c
SDO23c
SEO23c
SFO23c
SGO23c
3167.
3324.
5432.
8267.
15188.
33048.
SBG33c
SCG33c
SDG33c
SEG33c
SFG33c
SGG33c
4193.
4620.
8067.
12027.
21284.
49455.
SBA33c
SCA33c
SDA33c
SEA33c
SFA33c
SGA33c
5958.
6386.
10061.
15885.
27693.
59396.
SBO33c
SCO33c
SDO33c
SEO33c
SFO33c
SGO33c
4077.
4449.
7554.
11228.
20487.
43388.
Two Winding
Constanta
To r q u e
or
Variable
To r q u e
0
1
2
3
4
5
3
7-1/2
10
25
40
75
3
7-1/2
15
30
50
100
5
10
25
50
100
200
SBG24c
SCG24c
SDG24c
SEG24c
SFG24c
SGG24c
3252.
3452.
5817.
9005.
15929.
37335.
SBA24c
SCA24c
SDA24c
SEA24c
SFA24c
SGA24c
4577.
4778.
7353.
12639.
22338.
49058.
SBO24c
SCO24c
SDO24c
SEO24c
SFO24c
SGO24c
3167.
3324.
5432.
8267.
15188.
33048.
SBG34c
SCG34c
SDG34c
SEG34c
SFG34c
SGG34c
4193.
4620.
8067.
12027.
21284.
49455.
SBA34c
SCA34c
SDA34c
SEA34c
SFA34c
SGA34c
5958.
6386.
10061.
15885.
27693.
59396.
SBO34c
SCO34c
SDO34c
SEO34c
SFO34c
SGO34c
4077.
4449.
7554.
11228.
20487.
43388.
Table 17.72: Class 8810—Non-Reversing, Vertically Arranged, Open Type, Two-Speed Starters
Type
of
Motor
NEMA
Size
Maximum HP Ratings For Consequent Pole Motors For Separate Winding Motors
200 V 230 V 380 V 460-575 V Type $ Price Type $ Price
Constant
Horsepower
0
1
2
3
4
2
5
7-1/2
20
30
2
5
10
25
40
3
7-1/2
20
40
60
3
7-1/2
20
40
75
SBO11c
SCO11c
SDO11c
SEO11c
SFO11c
2142.00
2282.00
4050.00
6101.00
15786.00
SBO13c
SCO13c
SDO13c
SEO13c
SFO13c
1515.00
1686.00
2939.00
4563.00
11429.00
Constant
To r q u e
or
Var iable
To r q u e
0
1
2
3
4
3
7-1/2
10
25
40
3
7-1/2
15
30
50
5
10
25
50
75
5
10
25
50
100
SBO12c
SCO12c
SDO12c
SEO12c
SFO12c
2142.00
2282.00
4050.00
6101.00
15786.00
SBO14c
SCO14c
SDO14c
SEO14c
SFO14c
1515.00
1686.00
2939.00
4563.00
11429.00
Table 17.73: Coil Voltage Codes
Vol tage Code $ Price Adder
60 Hz 50 Hz
24ed
120e
208
240
480
600
Specify
110
220
380
440
550
Specify
V01
V02
V08
V03
V05
V06
V07
V99
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
35.60
CP1 Discount
Schedule
www.schneider-electric.us
17-28 © 2012 Schneider Electric
All Rights Reserved
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Multispeed Magnetic
Starters
Two-Speed Magnetic Starters
Class 8810 / Refer to Catalog 8502CT9701
aConsequent pole type starters consist of two 3-pole starters as pictured in Figure 4 and an additional 2-pole shorting contactor (not shown),
all on a common baseplate, horizontally mounted.
bCurrent transformers used with Size 1 overload relay blocks.
cSolid-state overload relays and special current transformers.
Table 17.74: NEMA Type 1 Enclosure (see Figure 1)
Type A B C D E F G H
SBG and SCG 11-7/8 11-7/8 7-17/32 9-3/4 1-1/16 1-1/16 9-3/4 5/16
SDG 14-7/8 14-1/8 7-21/32 12-3/4 1-1/16 1-1/16 12 5/16
SEG3 & 4 and SFG3 & 4 18-5/32 29-5/32 9-15/64 15-1/2 1-11/32 1-11/32 26-1/2 7/16
SEG1 & 2 and SFG1 & 2 22-5/32 39-5/32 10-15/64 19-1/2 1-11/32 1-11/32 36-1/2 7/16
SGG1, 2, 3, 4 20-7/32 65-3/4 16-29/64 31 2-1/8 2-1/8 42 9/16
SHG1, 2, 3, 4 36-7/32 62-7/32 19-15/32 Floor Mount
SJG3 & 4 Consult Square D
(4) H Dia. Mtg. Holes
G
DE
A
B
F
C
JI
RESET RESET
Figure 1:
NEMA Type 1, 4, and 12 Enclosures
Table 17.75: NEMA Type 4 Enclosure (see Figure 1)
Type A B C D E F G H I J
SBW and SCW 12-5/8 14-11/16 7-13/16 4-1/4 4-3/16 19/32 13-1/2 5/16 1-21/32 2-5/16
SDW 14-7/8 15-3/4 8-1/4 4-1/4 5-5/16 3/8 15 5/16 2-1/32 2-5/8
SEW3 & 4 and SFW3 & 4 18-5/32 32-7/32 8-19/64 12 3-5/64 55/64 30-1/2 7/16 2-37/64 3-3/16
SEW1 & 2 and SFW1 & 2 22-5/32 42-7/32 9-49/64 16 3-5/64 55/64 40-1/2 7/16 2-21/64 2-57/64
SGW1, 2, 3, 4 35-7/32 49-7/32 12-1/8 27 4-3/32 39/64 48 9/16 2-63/64 3-1/2
Table 17.76: NEMA Type 12/3R Enclosure (see Figure 1)
Type A B C D E F G H
SBA and SCA 11-7/8 13-1/2 7-3/4 4-1/4 3-13/16 3/8 12-3/4 5/16
SDA 14-7/8 15-3/4 7-7/8 4-1/4 5-5/16 3/8 15 5/16
SEA3 & 4 and SFA3 & 4 18-5/32 31-1/2 9-19/32 16 3-3/32 1/2 30-1/2 7/16
SEA1 & 2 and SFA1 & 2 22-5/3 41-1/2 10-19/32 16 3-3/32 1/2 40-1/2 7/16
SGA1, 2, 3, 4 35-7/32 49 13-7/64 27 4-7/64 1/2 48 9/16
SHA1, 2, 3, 4 36-7/32 62-7/32 19-15/32 Floor Mount
SJA3 & 4 Consult Square D
RESET RESET
A
DF
EG
I
HB
N
J
L
K
C
P
M
Trave l
Figure 2:
Class 8810 NEMA Sizes 0, 1, and 2
Table 17.77: Non-Reversing, Open Type
Fig.
No.
NEMA
Size Type Mtg.
Holes A B C D E F G H I J K L M N
2
0 and 1
SBO1, 2
SCO1, 2 4 9-5/8 7-11/32 5-5/16 8 5/8 7/32 6-29/32 7/32 4-3/4 2-1/4 5-1/16 19/32
SBO3, 4
SCO3, 4 3 7-1/8 6-29/32 5-5/16 — 3-13/32 15/32 6-7/32 — 7/32 3-9/16 1-5/8 5-1/16 19/32
2SDO1, 2 6 12-1/32 8-17/32 6-1/32 10-3/8 1/2 1/4 8-1/8 6-1/4 5/32 5-3/4 2-13/16 5-5/32 25/32
SDO3, 4 3 9 8-1/16 6-1/32 4-1/2 3/8 7-1/2 3/16 4-11/32 2-5/32 5-5/32 25/32
3
3SEO1, 2 4 18 14-7/16 17 12-1/4 1-1/2 11/16 1/2 6-7/16 7-3/8 1-21/32 2-5/32
SEO3, 4 4 12-3/4 12-9/32 11-3/4 10-3/4 1-1/32 1/2 1/2 2-1/2 6-3/4 1-5/32 1-5/32
4SFO1, 2 4 18-5/8 15-19/32 17 12-1/4 1-27/32 1-1/2 1-1/8 6-7/16 7-21/32 1-21/32 1-21/32
SFO3, 4 4 14-1/4 14-19/32 13-1/4 12-1/4 1-27/32 1/2 1/2 2-15/16 7-3/8 1-21/32 1-21/32
45
SGO1, 2a4 29-9/32 20-9/32 9-3/8 5-13/32 1-9/32 28 5/8 12-9/16 19 5/8 22-17/32 1/2 2-13/32 6-5/8
SGO3, 4 4 19-9/32 20-9/32 9-3/8 5-13/32 1-9/32 18 5/8 2-5/8 19 5/8 12-17/32 1/2 2-13/32 6-5/8
46bSHO1, 2a4 29-17/32 22-7/16 9-17/32 6-31/32 3-13/16 28 3/4 11-5/8 21-3/16 5/8 9-7/8 9/16 3-1/32 9-5/16
SHO3, 4 4 19-17/32 22-7/16 9-17/32 6-31/32 3-13/16 18 3/4 21-3/16 1-11/16 5/8 9-7/8 9/16 3-1/32 9-5/16
—7cSJO3, 4 Consult the Customer Care Center (CCC) at 1-888-778-2733.
RESET
RESET
J
GHI
DB
K
F
Prov. for (4) .31 Dia. Mtg. Screws
8
.50
13
.50
13
.50
13
C
A
E
.56
14
6.25
159
Reset
Trave l
7.00
178
Figure 3: Class 8810 NEMA Sizes 3 and 4
G
F
A
E
B
D
MM
M
H M
K
J
(4) L Dia. Mtg. Holes
C
I
N
Figure 4: Class 8810 NEMA Size 5 and 6
NOTE: Illustrations are intended for
dimensional information only
and may not represent the
actual enclosure. Dimensions
are shown in inches.
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-29
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Multispeed Magnetic
Starters
Approximate Dimensions
Class 8810 / Refer to Catalog 8502CT9701
Disconnect Switch or Circuit Breaker Type
aSize 3 (5-Pole–3-Pole) with FA, KA circuit breaker or 100 A disconnect switch.
Size 4 (5-Pole–3-Pole) with KA circuit breaker or 200 A disconnect switch. Size 3 & 4 (3-Pole–3-Pole) enclosures may be smaller.
Consult the Customer Care Center (CCC) at 1-888-778-2733 for additional dimensional information.
Table 17.78: NEMA Type 1 Enclosure, Figure 1
NEMA
Size Class Type
Dimensions (in inches)—see Figure 1 Top & Bottom Sides
A B C D E F G H I J K L M N O W X Y
0–1 8810 CBG UBG DBG
CCG UCG DCG 13-7/8 23-1/8 8-1/4 10-5/8 21 19-9/32 1-7/8 1-7/8 3-3/4 2-5/16 1-1/16 3-19/64 2-3/16 1-1/4 7/8 1/2–3/4–1 1/2–3/4–1 1/2
2 8810 CDG UDG DDG 15-5/32 28-29/32 9-9/16 11-5/8 26-1/4 21-13/16 2-3/16 2 4 2-5/8 1-21/64 3-19/64 2-7/32 1-17/64 29/32 1–1-1/4 1/2–3/4 1/2
3a8810 CEG UEG DEG 22-1/8 42-5/8 10-1/8 18-5/8 40 29-1/8 2-11/32 2-1/8 4-1/4 2-5/8 1-1/4 3-19/64 2-1/4 7/8 3/4 1–1-1/4–1-1/2 1/2–3/4 1/2
4a8810 CFG UFG DFG 22-1/8 50-1/8 10-3/16 18-5/8 47-1/2 29-3/16 2-29/32 2-11/16 5-3/8 2-5/8 1-5/16 3-19/64 2-1/4 7/8 3/4 2-1/2 1/2–3/4 1/2
Table 17.79: NEMA Type 4 Enclosure, Figure 2
NEMA
Size Class Type
Dimensions (in inches)—see Figure 2 Bottom Top &
Bottom
A B C D E F G H I J K L W X
0–1 8810 CBW UBW DBW
CCW UCW DCW 13-7/8 8-21/64 25-3/16 3-19/64 2-9/16 8-3/4 24 19/32 3-61/64 1-5/8 2-5/16 18-17/32 3/4 Hub 1 Hub
2 8810 CDW UDW DDW 15-1/8 9-37/64 30-15/16 3-19/64 2-9/16 10 29-3/4 19/32 3-61/64 2 2-5/8 21-11/32 3/4 Hub 1-1/2 Hub
3a8810 CEW UEW DEW 22-1/8 10-1/8 46-1/4 3-19/64 3 16 44 5/8 3-15/16 1-3/4 2-5/8 29-1/8 3/4 Hub 2 Hub
4a8810 CFW UFW DFW 22-1/8 10-3/16 53-3/4 3-19/64 3 16 51-1/2 5/8 3-15/16 2-9/32 3-3/16 29-3/16 3/4 Hub 2-1/2 Hub
Table 17.80: NEMA Type 12 Enclosure, Figure 3
NEMA
Size Class Type
Dimensions (in inches)—see Figure 3
A B C D E F G H I J
0–1 8810 CBA UBA DBA
CCA UCA DCA 13-7/8 10-3/32 24-3/4 3-19/64 2-9/16 8-3/4 24 3/8 3-61/64 20-9/32
2 8810 CDA UDA DDA 15-5/32 10-31/32 31-1/4 3-19/64 3-5/64 9 30-1/4 1/2 4-53/64 23-7/16
3a8810 CEA UEA DEA 22-1/8 10-1/8 45 3-19/64 3 16 44 5/8 3-15/16 29-1/8
4a8810 CFA UFA DFA 22-1/8 10-3/16 52-1/2 3-19/64 3 16 51-1/2 5/8 3-15/16 29-3/16
O
N
C
HANDLE
SWING
EB
K
M
D
A
Y
(4) .31 DIA. MTG.HOLES
(for Size 0, 1, & 2)
8
F
WXW
G
J
H
I
COVER OPEN 90°
L
Y
Figure 1:
NEMA Type 1 Enclosure
B
HANDLE
SWING
C
F
A
(4) .31 DIA. MTG.HOLES
(for Size 0, 1, & 2)
8
L
WX
I
COVER OPEN 90°
D
E
K
J
G
H
Figure 2:
NEMA Type 4 Enclosure
B
HANDLE
SWING
C
F
A
(4) .31 DIA. MTG.HOLES
(for Size 0, 1, & 2)
8
J
I
D
E
G
H
Figure 3:
NEMA Type 12 Enclosure
NOTE: Illustrations are intended for dimensional
information only and may not represent the
actual enclosure. Dimensions are shown
in inches.
www.schneider-electric.us
17-30 © 2012 Schneider Electric
All Rights Reserved
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Lighting Contactors Panelboard Lighting Contactors, Type PB
Class 8903 / Refer to Catalog 8903CT9701
General Information
Panelboard lighting contactors, sometimes called remote
control switches, are designed for use with lighting
panelboards and motor control centers where either panel
or bus mounting is desired. Type PB lighting contactors
can be used in a retrofit or new project without increasing
the panelboard depth. They can be used to directly
replace many inoperative existing switches.
The features include: mechanically held; compatible with
Square D panelboards; short-circuit ratings to 100 kA;
compact arc suppression; bus or panel mounted; fits in
standard-depth lighting panelboards; easy manual
operation; standard coil clearing contacts; and operates in
any position.
aVoltage code must be specified to order this product. Refer to standard
voltage codes listed below.
bSlotted mounting holes suitable for 2.88–3.19 in. mounting centers.
Panel Mount
Table 17.81: Class 8903 Type PB Lighting Contactors
Description Bus Mount Panel Mount (Includes Lugs)
Size (A) Poles Type $ Price Type $ Price
30 2
3
PBM 10Ba
PBM 11Ba
2129.00
2403.00
PBM 10a
PBM 11a
2640.00
2973.00
60 2
3
PBP 10Ba
PBP 11Ba
2237.00
2573.00
PBP 10a
PBP 11a
2762.00
3185.00
75 2
3
PBN 10Ba
PBN 11Ba
2237.00
2573.00
PBN 10a
PBN 11a
2762.00
3185.00
100 2
3
PBQ 10Ba
PBQ 11Ba
2541.00
2978.00
PBQ 10a
PBQ 11a
3119.00
3546.00
150 2
3
PBR 10Ba
PBR 11Ba
3162.00
4055.00
PBR 10a
PBR 11a
3897.00
4787.00
200 2
3
PBV 10Ba
PBV 11Ba
3551.00
4496.00
PBV 10a
PBV 11a
4409.00
5360.00
225 2
3
PBW 10Ba
PBW 11Ba
3909.00
4958.00
PBW 10a
PBW 11a
4964.00
5990.00
Table 17.82: AC Coil Voltage Codes
60 Hz Voltage Code
120
208
240/277
480
V02
V08
V39
V28
Table 17.83: Class 8903—Auxiliary Contacts
Type Description $ Price
PBX1
PBX2
(1) Auxiliary Contact SPDT
(2) Auxiliary Contacts SPDT
243.00
485.00
Table 17.84: Factory Modifications
Form Description $ Price
X11
X22
(1) Auxiliary Contact SPDT
(2) Auxiliary Contacts SPDT
158.00
314.00
Table 17.85: Dimensions (Panel Mount)
Amperes
Dimensions
H W D A B C E
in. mm in. mm in. mm in. mm in. mm in. mm in. mm
30–
100 11.75 298 7.50 191 3.88 98 2.25 57 7.38 187 2.25 57 9.25 235
150–
225 14.50 368 7.50 191 3.88 98 2.88 73 8.50 216 3.00 76 10.50 267
File E78427
CCN NRNT
B
C
A A
WD
E
H
Table 17.86: Control Distance
Wire Gauge
AWG
Maximum Distance (feet)
120 V 208 V 240 V 277 V 480 V
#14
#12
#10
550
900
1425
1650
2700
4275
2200
3600
5700
2925
4700
7550
8800
14400
22800
Table 17.87: Short-Circuit Ratings
RMS Sym.
Current (A) Max. Volts Short Circuit
Protection Device Recommended
100,000
22,000
65,000
600
600
240
Class J Fuses
Circuit Breaker—Square D—Type LHL
Circuit Breaker—Square D—Type LHL
Table 17.88: Maximum Wire Size (AWG)
Current Range Power Wire
(Cu/Al)
Control Wire
(Cu Only)
30–100 A
150–225 A
#1/0 Max.
350 MCM Max.
#18–#10
#18–#10
Table 17.89: Dimensions (Bus Mount)
Amperes
Dimensions
H W D A B
in. mm in. mm in. mm in. mm in. mm
30–
100 8.31 211 7.50 191 3.38 86 2.25 57 7.38 187
150–
225 9.50 241 7.50 191 3.38 86 2.88b73 8.50 216
B
A A
WD
H
CP1 Discount
Schedule
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-31
17 NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Well-Guard™ Pump Panel Reduced Voltage Type
Class 8940 / Refer to Catalog 8940CT9701
Class 8940 reduced voltage panels in NEMA 3R
enclosures are specifically designed for pumping
applications. Extra space is provided for field installation of
auxiliary equipment.
Type S contactors/starters provided as standard
All devices are UL Listed, and marked “SUITABLE
ONLY FOR USE AS SERVICE EQUIPMENT”
Price includes Hand-Off-Auto selector switch and Start
push button
For How to Order Information, see Digest 176 page 16-12
and Digest 176 page 16-125 for selection information.
c24 V coils are not available on Sizes 4–7. On Sizes 2–3, where 24 V
coils are available, Form S (separate control) must be specified.
dThis voltage code must include Form S (no charge).
aFuse clips are sized for use with dual-element time-delay fuses. bCoil voltage code must be specified to order this product. Refer to
standard voltage codes shown in Table 17.90.
cFuse clips are sized for use with dual-element time-delay fuses. dCoil voltage code must be specified to order this product. Refer to
standard voltage codes shown in Table 17.90.
aCabinet has double doors. NOTE: Illustrations may not represent the actual enclosure; they are
intended for dimensional information only.
Table 17.90: Coil Voltage Codes
Vol tage Code $ Price Adder
60 Hz 50 Hz
24c
120d
208
240
480
600
Specify
110
220
380
440
550
Specify
V01
V02
V08
V03
V05
V06
V07
V99
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
35.60
Table 17.91: Closed Transition Autotransformer Type, 3-Pole Polyphase—480 Vac Maximum (50–60 Hz)
Note: The prices shown do not include thermal units. Overload relays are ambient temperature compensated. Devices require 3 thermal units (Sizes 2–6). Standard trip thermal units are $21.50 each.
Motor
(Starter)
Vol ts
Max. HP
Polyphase
Coil
Vol tage
NEMA
Size
Fusible Disconnect Type Circuit Breaker Type
Fuse Clip
AmperesaTypeb$ Price Circuit Breaker Typeb$ Price
230
(240)
15
240@ 60 Hz
220@ 50 Hz
260RD4DV03 11928.00 FAL36080 VD1DV03 11928.00
25 3100 RE4FV03 17055.00 FAL36100 VE1FV03 17055.00
30 200 RE1GV03 17342.00 KAL36100 VE2GV03 17342.00
50 4 200 RF4JV03 26657.00 KAL36200 VF1JV03 28107.00
75 5400 RG1LV03 43946.00 LAL36250 VG2LV03 43946.00
100 400 RG1MV03 46083.00 LAL36350 VG2MV03 46083.00
460
(480)
25
480 @ 60 Hz
440 @ 50 Hz
260RD2FV06 12555.00 FAL36070 VD1FV06 12555.00
30 3100 RE2GV06 17085.00 FAL36080 VE1GV06 17085.00
50 100 RE2JV06 18197.00 FAL36100 VE1JV06 18197.00
75 4 200 RF2LV06 26657.00 KAL36125 VF1LV06 27872.00
100 200 RF2MV06 28278.00 KAL36200 VF1MV06 28278.00
150 5 400 RG3PV06 42735.00 LAL36250 VG4PV06 46340.00
200 400 RG3QV06 48860.00 LAL36350 VG4QV06 51237.00
300 6 —— MAL36600 VH1SV06 79338.00
400 — — MAL36900 VH2TV06 79338.00
600 7 — MAL361000 VJ1WV06 123134.00
Type VG4V06K15
Table 17.92: Part Winding Type, 3-Pole Polyphase—480 Vac Maximum (50–60 Hz)
Note: The prices shown do not include thermal units. Overload relays are ambient temperature compensated. Devices require 6 thermal units (Sizes 2–6). Standard trip thermal units are $21.50 each.
Motor
(Starter)
Vol tage
Max. HP
Polyphase
Coil
Vol tage
NEMA
Size
Combination Fusible Disconnect Type Combination Circuit Breaker Type
Fuse Clip
(2 Sets)
(A)c
Typed$ Price
Circuit Breaker
(2 Bkrs.)
Frame Size
Typed$ Price
230
(240)
25
240 @ 60 Hz
220 @ 50 Hz
2PW 60 MD4FV03 7536.00 FAL36070 PD1FV03 7923.00
30 3PW 60 ME5GV03 11609.00 FAL36080 PE3GV03 11322.00
50 100 ME6JV03 11609.00 FAL36100 PE3JV03 11322.00
75 4PW 200 MF1LV03 21821.00 KAL36150 PF3LV03 23400.00
100
5PW
200 MG3MV03 43326.00 KAL36175 PG2MV03 43326.00
125 400 MG1NV03 43326.00 LAL36250 PG3NV03 43326.00
150 400 MG1PV03 43326.00 LAL36250 PG3PV03 43326.00
460
(480)
30
480 @ 60 Hz
440 @ 50 Hz
2PW 30 MD5GV06 7536.00 FAL36040 PD1GV06 7293.00
40 60 MD2HV06 7536.00 FAL36050 PD1HV06 7293.00
60 3PW 60 ME7KV06 11609.00 FAL36070 PE3KV06 12822.00
75 100 ME3LV06 11609.00 FAL36090 PE3LV06 11322.00
100 4PW 200 MF3MV06 23400.00 FAL36100 PF2MV06 23400.00
150 200 MF3PV06 23400.00 KAL36125 PF3PV06 23400.00
200
5PW
200 MG4QV06 43326.00 KAL36175 PG2QV06 43326.00
250 200 MG4RV06 43326.00 KAL36225 PG3RV06 43326.00
350 400 MG2TV06 43326.00 LAL36300 PG3TV06 43326.00
Table 17.93: Part Winding—Reduced Voltage Type
Type Figure A B C D E F
in. mm in. mm in. mm in. mm in. mm in. mm
PD 3 19.00 483 34.50 876 12.25 311 13.00 330 33.50 851 0.44 11
MD 3 23.00 584 25.50 648 10.60 269 17.00 432 24.50 622 0.44 11
PE, PF 3 30.00 762 47.00 1194 13.25 337 22.00 559 46.00 1168 0.56 14
ME 3 25.00 635 52.50 1334 12.13 308 19.00 483 51.50 1308 0.44 11
MF 4 36.00 914 93.00 2362 19.25 489 33.75 857 12.50 318 0.69 18
PG, MG 4 36.00 914 73.00 1854 19.25 489 33.75 857 12.50 318 0.69 18
PH 4 38.00 965 93.00 2362 19.25 489 35.75 908 12.50 318 0.69 18
Table 17.94: Autotransformer—Reduced Voltage Type
Type Figure A B C D E F
in. mm in. mm in. mm in. mm in. mm in. mm
RD, VD 3 25.00 635 52.50 1334 11.13 283 19.00 483 51.50 1308 0.44 11
RE, VE, RF, VF 4 32.00 813 72.50 1842 19.25 489 29.75 756 12.50 318 0.68 17
RG 4 36.00 914 93.00 2362 19.25 489 33.75 857 12.50 318 0.69 17
VG 4 32.00 813 72.50 1842 19.25 489 29.75 756 12.50 318 0.68 17
VH 4 34.00 864 93.00 2362 23.25 591 31.75 806 16.50 419 0.69 17
VJa4 64.00 1626 93.00 2362 27.25 692 61.75 1568 17.25 438 0.81 21
CP1 Discount
Schedule
17-32 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Factory Modifications
(Forms)
Reduced Voltage Starters
Classs 8606, 8630, 8640
aAll push buttons are momentary contact.
bFor pilot light details, refer to the pilot light table in Digest 176 page 16-100.
cSee Table 17.96 below.
dAs standard, Reduced Voltage Controllers are supplied with common control. If Form S or T is specified, only the TR coil will be at control voltage.
Specify Form Y195 or T40 (Ex. Form F4T40) if all coils must be at control voltage. Refer to page 17-18 for control circuit arrangements.
eReduced Voltage Controllers are supplied with two control circuit fuses for conductors at line voltage. Additional fusing may be supplied if a fused control
circuit transformer or separate control is specified.
fMust be used with Form specifying separate control (Ex. Form FS).
gAdd Form letters and price to that of standard control transformer. (Example: For Size 1, Form F4T, plus 100 VA becomes F4T11, $984.00
Form F4T40 plus 100 VA becomes F4T41, $807.00).
hSize 6 and 7 controllers come with Form F4T as standard.
iMust be used in conjunction with a variation of Form of F4T. (Ex. Standard capacity transformer required, 208–24 V. Order as Form F4TT1, 208–24 V.)
The standard primary and secondary voltages for control circuit transformers are indicated in Table 17.96.
To order, select the desired device with the appropriate transformer Form designation. Then convert the previously
selected voltage code (V••) to reflect the desired primary/secondary voltage for the transformer. The secondary voltage
should equal the previously selected coil voltage of the device. (24 Vac coils for NEMA Sizes 4–7 are not available).
Example:
You previously selected a Class 8606SDG1V02S. The designation V02S means that you need a coil voltage of
120-60/110-50 wired for separate control. You would like to add Form FF4T with the transformer voltages being 480
volt primary, 120 volt secondary. The new, complete Class, Type, Voltage Code, and Form are:
jForm numbers should always be shown in alphabetical order.
Table 17.95: Reduced Voltage Controllers Only
Classes 8606, 8630, 8640
Factory Modifications Enclosure
Type Form
NEMA Size
1
1PW
1 YD
2
2 PW
2 YD
3
3 PW
3 YD
4
4 PW
4 YD
5
5 PW
5 YD
6
6 PW
6 YD
7
7 PW
7 YD
Pilot Devices in Cover and
Control Circuit
Reduced Voltage
Controllers Only
Classes
8606
8630
8640
8647
8650
Push Buttonsa
Start-Stop 1, 4, 12 A 336.00 336.00 336.00 33600 336.00 336.00 336.00
Selector Switches
Hand-Off-Auto 1, 4, 12 C 336.00 336.00 336.00 336.00 336.00 336.00 336.00
On-Off 1, 4, 12 C6 336.00 336.00 336.00 336.00 336.00 336.00 336.00
Pilot Lights (specify color)b
One light On 1, 4, 12 P 336.00 336.00 336.00 336.00 336.00 336.00 336.00
Separate Control Circuitde
TR coil only (at control voltage) 1, 4, 12 S N/C N/C N/C N/C N/C N/C N/C
All coils (at control voltage) 1, 4, 12 Y195 N/C N/C N/C N/C N/C N/C N/C
Fused Control Circuitcdef
One fuse 1, 4, 12 F 314.00 314.00 314.00 314.00 314.00 N/ChN/Ch
Two fuses 1, 4, 12 F4 314.00 314.00 314.00 314.00 314.00 N/ChN/Ch
Control Circuit Transformercde
Standard Capacity (50 or 60 Hz)
Fuses
Primary Secondary
2— 0— 1, 4, 12 F4T 684.00 882.00 1112.00 1254.00 1395.00 N/ChN/Ch
2.. 1— 1, 4, 12 FF4T 1026.00 1197.00 1425.00 1566.00 1710.00 314.00 314.00
2— 0— 1, 4, 12 F4T40 912.00 1182.00 1938.00 2079.00 3803.00 3803.00 3803.00
2— 1— 1, 4, 12 FF4T40 1224.00 1497.00 2250.00 2393.00 4116.00 4116.00 4116.00
Additional capacity (50 or 60 Hz)g
100 VA additional capacity 1, 4, 12 T11 300.00 300.00 300.00 300.00 300.00 300.00 300.00
200 VA additional capacity 1, 4, 12 T12 570.00 570.00 570.00 570.00 570.00 570.00 570.00
300 VA additional capacity 1, 4, 12 T13 1139.00 1139.00 1139.00 1139.00 1139.00 1139.00 1139.00
400 VA additional capacity 1, 4, 12 T14 2421.00 2421.00 2421.00 2421.00 2421.00 2421.00 2421.00
500 VA additional capacity 1, 4, 12 T15 2721.00 2721.00 2721.00 2721.00 2721.00 2721.00 2721.00
Substitute nonstandard single primary and/or single secondary
Voltage rating on the control transformerc1, 4, 12 T1i71.00 71.00 71.00 71.00 71.00 ——
Table 17.96: Selection of Control Circuit Transformers
Voltage
60 Hz (Primary–Secondary) Code
120–12
120–24
208–120
240–24
240–120
277–120
480–24
480–120
480–240
600–120
Specify
V88
V89
V84
V82
V80
V85
V83
V81
V87
V86
V99
Class Type Voltage Code Formj
8606 SDG1 V81 FF4T
CP1 Discount
Schedule
www.schneider-electric.us
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
© 2012 Schneider Electric
All Rights Reserved 17-33
Factory Modifications
(Forms)
Reduced Voltage Starters
Class 8606, 8630
Table 17.97: Class 8606 Reduced Voltage Starters Only
Factory Modifications Enclosure
Type Form NEMA Size
1 2 3 4 5 6 7
Circuit
Breaker
or
Disconnect
Switch
Molded case thermal magnetic circuit breaker b
1Y7912010.00 2451.00 2664.00 4872.00 9471.00 13944.00 18320.00
4Y7912862.00 3533.00 4886.00 7092.00 11808.00 18216.00 23601.00
12 Y791 2037.00 2564.00 2862.00 6579.00 10839.00 15012.00 20397.00
Nonfusible disconnect switch
1Y7921340.00 1710.00 2165.00 2991.00 5355.00
4Y7922195.00 2793.00 4388.00 5327.00 7691.00
12 Y792 1368.00 1823.00 2366.00 4815.00 5925.00
Atuomatic molded case switch
1 Y7910 — — — — — 12293.00 13004.00
4 Y7910 — — — — — 16565.00 17276.00
12 Y7910 — — — — — 13361.00 14072.00
Fusible Disconnect Switch with Fuse Clips a
30 A clips
1 Y7931566.00 1566.00 — — — — —
4Y7932421.00 2124.00 — — — — —
12 Y793 1596.00 1596.00 — — — — —
60 A clips
1Y7941566.00 1823.00 2066.00 — — — —
4Y7942421.00 2885.00 3609.00 — — — —
12 Y794 1596.00 1938.00 2280.00 — — — —
100 A clips
1Y795 — — 2336.00 2574.00 — — —
4Y795 — — 4559.00 5021.00 — — —
12 Y795 — — 2537.00 2943.00 — — —
200 A clips
1Y796 — — 2885.00 3596.00 — — —
4Y796 — — 5129.00 4340.00 — — —
12 Y796 — — 3105.00 5327.00 — — —
400 A clips
1Y797 — — — — 5868.00 11039.00 —
4Y797 — — — — 8190.00 15354.00 —
12 Y797 — — — — 6438.00 12861.00
Automatic Molded Case Switch
with 600 A fuse clips
1Y798 — — — — — 13802.00 —
4Y798 — — — — — 18075.00 —
12 Y798 — — — — — 14871.00 —
Automatic Molded Case Switch
with fuse clips 1200 A or less
1Y799 ——————15425.00
4Y799 ——————19697.00
12 Y799 ——————17562.00
aFuses not included.
bMag-Gard™ circuit breakers are not supplied nor recommended.
Table 17.98: Class 8630 Reduced Voltage Controllers Onlyd
Factory Modifications Enclosure
Type Form NEMA Size
1 YD 2 YD 3 YD 4 YD 5 YD 6 YD 7 YD
Circuit
Breaker
or
Disconnect
Switch
Molded case thermal magnetic circuit breaker e
1Y7912451.00 2664.00 4872.00 9471.00 13944.00 18320.00 32759.00
4Y7913533.00 4886.00 7092.00 11808.00 18216.00 23601.00 37031.00
12 Y791 2564.00 2856.00 6579.00 10839.00 15012.00 20397.00 33827.00
Nonfusible disconnect switch
1Y7921710.00 2165.00 2991.00 5355.00 — — —
4Y7922793.00 4388.00 5327.00 7691.00 — — —
12 Y792 1823.00 2366.00 4815.00 5925.00 — — —
Atuomatic molded case switch
1 Y7910 — 12293.00 13004.00 29483.00
4 Y7910 — 16565.00 17276.00 33755.00
12 Y7910 — 13361.00 14072.00 30551.00
Fusible Disconnect Switch with Fuse Clipsc
30 A clips
1 Y7931823.00 1823.00 — — — — —
4Y7932421.00 3771.00 — — — — —
12 Y793 1938.00 1938.00 — — — — —
60 A clips
1Y7941823.00 2066.00 — — — — —
4Y7942421.00 3609.00 — — — — —
12 Y794 1938.00 2280.00 — — — — —
100 A clips
1Y795 2336.00 2574.00 — — — —
4Y795 4559.00 5021.00 — — — —
12 Y795 2537.00 2943.00 — — — —
200 A clips
1Y796 — — 2885.00 3596.00 — — —
4Y796 — — 5129.00 5840.00 — — —
12 Y796 — — 3105.00 5327.00 — — —
400 A clips
1Y797 — — — 6510.00 11039.00 — —
4Y797 — — — 8204.00 15354.00 — —
12 Y797 — — — 6438.00 12861.00 — —
Automatic Molded Case Switch
with 600 A fuse clips
1Y798 — — — — 13802.00 14513.00 —
4Y798 — — — — 18075.00 18786.00 —
12 Y798 — — — — 14871.00 15227.00 —
Automatic Molded Case Switch
with fuse clips 1200 A or less
1Y799 — — — — — 15425.00 30195.00
4Y799 — — — — — 19697.00 34704.00
12 Y799 — — — — — 17562.00 31095.00
cFuses not included.
dWye-Delta motor starters typically have higher current ratings per NEMA Size than full voltage motor starters. Care must be taken in selecting the appropriate short circuit protection.
The table on Digest 176 page 7-33 will assist in selecting proper protection based on motor full-load current.
eMag-Gard™ circuit breakers are not supplied nor recommended.
CP1 Discount
Schedule
www.schneider-electric.us
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
17-34 © 2012 Schneider Electric
All Rights Reserved
Factory Modifications
(Forms)
Reduced Voltage Starters
Class 8640, 8606, 8630
NOTE: To comply with Section 430-3 of the National Electrical Code®, combination part-winding starters are
provided as follows:
1. Circuit breaker: two thermal-magnetic, adjustable-trip circuit breakers—one for each motor winding. In the smaller controllers that
use the FA and KA frames, a single external operating mechanism operates the two circuit breakers simultaneously. In the larger
controllers that use the KA and LA frames, each circuit breaker has its own operating mechanism.
2. Nonfusible disconnect switch: a single 3-pole unfused disconnect switch of the proper rating for both windings. The user must
provide proper short-circuit protection external to the starter, using only Class J fuses.
3. Fusible disconnect switch: a single unfused disconnect switch with two sets of fuse clips (each set of the rating indicated) to provide
short-circuit protection for each winding.
Table 17.99: Class 8640 Reduced Voltage Starters Only
Factory Modifications Enclosure
Type Form
NEMA Size
1 PW 2 PW 3 PW 4 PW 5 PW 6 PW
Circuit
Breaker
or
Disconnect
Switch
Molded case thermal magnetic circuit breaker b
1 Y7911 3014.00 3675.00 3996.00 7307.00 14207.00
4 Y7911 4293.00 5300.00 7329.00 10641.00 17711.00
12 Y7911 3056.00 3846.00 4293.00 9872.00 16259.00
Fusible Disconnect Switch with Fuse Clips a
30 A clips (two sets)
1 Y79312006.00 2006.00
4 Y7931 2664.00 2664.00
12 Y7931 2132.00 2132.00
60 A clips (two sets)
1 Y7941 — 2273.00 2570.00
4 Y7941 — 3969.00 5013.00
12 Y7941 2507.00 2790.00
100 A clips (two sets)
1 Y7951 — 2570.00 2831.00 3176.00
4 Y7951 — 5013.00 5525.00 5642.00
12 Y7951 2790.00 3239.00 3416.00
200 A clips (two sets)
1 Y7961 3176.00 3959.00 6456.00
4 Y7961 5642.00 6425.00 9026.00
12 Y7961 3416.00 5859.00 7082.00
400 A clips (two sets)
1 Y7971 6456.00 15182.00 c15596.00 c
4 Y7971 9026.00 19881.00 c20082.00 c
12 Y7971 7082.00 16356.00 c16592.00 c
Automatic molded case switch
with 600 A fuse clips (two sets)
1 Y7920 — — — — 15965.00
4 Y7920 — — — — 20664.00
12 Y7920 — — — — 16748.00
Automatic molded case switch
with fuse clips 601–1200 A or less (two sets)
1 Y7921 — — — — 16968.00
4 Y7921 — — — — 21668.00
12 Y7921 — — — — 19319.00
aFuses not included.
bMag-Gard™ circuit breakers are not supplied nor recommended.
cConsists of automatic molded case switch with two sets of 400 A fuse clips.
Table 17.100: Reduced Voltage Controllers Onlyc
Classes 8606, 8630, 8640
Factory Modifications Enclosure
Type Form
NEMA Size
1
1PW
1 YD
2
2 PW
2 YD
3
3 PW
3 YD
4
4 PW
4 YD
5
5 PW
5 YD
6
6 PW
6 YD
7
7 PW
7 YD
Overload
Relays
Non-Compensated Bimetallic Overload Relays
Three Element
Types SC-SD (Sizes 1 & 2)
Types SE-SG (Sizes 3–5)
Type SH (Size 6)
Any
Any
Any
B2
B5
B2
57.00
57.00
57.00
57.00
57.00
57.00
b
Ambient Compensated Bimetallic Overload Relays
Three Element
Types SC-SD (Sizes 1 & 2)
Types SE-SF (Sizes 3 & 4)
Types SG-SH (Sizes 5–6)
1, 4, 12
Any
Any
B
Y59
B
86.00
86.00
107.00
107.00
86.00
86.00
b
Overload Relays General
Substitute 9999SO4 isolated alarm contact on melting alloy overload relay
Substitute 9999SO5 isolated alarm contact on melting alloy overload relay
Any
Any
Y342
Y344
179.00
179.00
179.00
179.00
179.00
179.00
179.00
179.00
179.00
179.00
179.00
179.00
b
b
Motor Logic™ Overload Relaysde Any
Any
H10
H20
122.00
122.00
122.00
122.00
122.00
122.00
122.00
122.00
122.00
122.00
57.00
57.00
57.00
57.00
Miscellaneous
Add for thermal protector Class 8606
Coil transient suppressor per coil
Addition of terminal blocks (specify wired or unwired).
Wired, per terminal, each
Unwired, per terminal, each
1, 4, 12
Any
1, 4, 12
1, 4, 12
Y116
Y145
G56a
G50a
158.00
116.00
57.00
570.00
158.00
116.00
57.00
570.00
158.00
116.00
57.00
570.00
158.00
116.00
57.00
570.00
158.00
116.00
57.00
570.00
116.00
57.00
116.00
57.00
aAddition of terminal block 9080CA or 9080GR6 only. The number of circuits is the same as the ending of the Form number. (Example: G505 is 5 wire terminal block.) Available in groups
of 5 only. Order in increments of 5. The number of circuits is the same as the ending of the Form number. (Example: G505 = 5 unwired terminals, G510 is 10 unwired terminals.)
bSize 7 uses a solid-state overload relay. See Class 8536 for complete details.
cNEMA Type 7 and 9 enclosures not available with Class 8600 devices.
dMotor Logic overload relays are not available on Class 8640 Size 1PW to 4PW starters.
eSee Motor Logic overload relays in the Full Voltage section on the bottom of Digest 176 page 16-83 for additional Form options of Motor Logic overload relays.
CP1 Discount
Schedule
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 17-35
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Definite Purpose
Contactors
Reversing/Hoist, Type R
Class 8965 / Refer to Catalog 8910CT9301
Class 8965 reversing hoist contactors meet the small
space requirements found in electrical hoists, light duty
cranes, door operators, and related products. They are
designed to perform in the short periods of jogging
experienced in hoist service. Note that these contactors
must be mounted upright on the vertical plane; the
contactors will not operate properly when mounted in any
other position.
fCP10 Discount Schedule.
gTape wound coils, 2 per package.
hMolded coil, 1 per package.
iSuitable for 440 V 50 Hz applications.
Type RO10V02
Table 17.101: AC Reversing/Hoist Contactors—600 Vac Maximum
No. of
Poles
Horsepower Ratings Power
Terminals
Witha
Jumper Straps
Withouta
Jumper Straps $ Price
115 V
1 Ø
230 V
1 Ø
230 V
3 Ø
460/575 V
3 Ø Open Type Open Type
3-Pole
Polyphase 11-1/23 3
Quick Connect RO10cRO11c998.00
Pressure WirebRO12cRO13c
aJumper straps connect the line side power terminals of the same phase between the forward (up) and reverse (down) contactors in common;
i.e., L1 to L1, L2 to L2, and L3 to L3.
bCoils rated 120 Vac or less are supplied with quick connect terminals only.
cVoltage code must be specified to order this product. Refer to standard voltage codes shown in Table 17.105.
Table 17.102: Miscellaneous Hoist Contactor Kits For Use With Class 8965
Type Series Description Class Type Series Description Class Type $ Priced
RO10
RO11
RO12
RO13
A & B
Armature Kit 9998 RP1e
C
Armature Kit 9998 RP2e29.40
Contact
Carrier
Order as Part Number
3100206050
Contact
Carrier
Order as Part Number
3100208150 39.40
dCP10 discount schedule.
eOne armature per kit.
Table 17.103: Class 8965 Replacement Contact Kits
Device
Type
Device
Series
Class 9998
Kit Type
Device
Series
Class 9998
Kit Type $ Price
RO10
A & B
RA10
C
RA14 202.00
RO11 RA11 RA15
RO12 RA12 RA16 236.00
RO13 RA13 RA17
Table 17.104: Auxiliary Contacts Separate Module
Description Terminals Class 9999
Type $ Price
1 N.O.
Each Side
Quick Connect R10
50.00
Screw R12
1 N.C.
Each Side
Quick Connect R11
Screw R13
Table 17.105: Coil Table
Voltage
60 Hz
Vol tage
50 Hz
Voltage
Code
Replacement
Part Number $ Pricef
24
120
208/220
240
480
600
110
220
440
550
V01
V02
V21
V03
V06
V07
3100240319g
3100240340g
3100240047h
3100240049h
3100240058hi
3100240060h
119.00
119.00
114.00
114.00
114.00
83.00
Table 17.106: Approximate Dimensions
(3 Poles per Contactor)
Type A B C D E F G
RO10, 11 3.31
84
3.31
84
3.03
77
2.69
68
1.34
34
1.56
40
2.66
68
RO12, 13 3.31
84
3.69
94
2.69
68
2.69
68
1.34
34
1.56
40
2.66
68
A
D
E
F
B
G
C
Provisions for
(3) #8 Mounting Screws
Table 17.107: Cross Reference—Obsolete Devices
Obsolete
Device
Replacement
Device
Auxiliary Contact
Required
Obsolete
Device
Replacement
Device
Auxiliary Contact
Required
Class Type Class Type Class Type Class Type Class Type Class Type
8702
or
8965
HO3
HO4
HO5
HO6
HO7
HO8
8965
RO12
RO12
RO12
RO12
RO12
RO12
9999
9999
9999
9999
R12
R13
R12
R13
8965
RO2
RO2S1
RO2S2
RO3
RO3S1
RO3S2
RO3S3
RO4
RO4S1
RO5
RO5S1
RO5S2
RO6
RO6S1
RO6S2
8965
RO10
RO11
RO10
RO10
RO11
RO10
RO10
RO12
RO13
RO12
RO13
RO12
RO12
RO13
RO12
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
R10
R10
R10
R11
R11
R11
R11
R12
R12
R12
R13
R13
R13
8965
RG2S1
RG5S1
RG5S2
RO1
RO1S1
RO1S2
RO1S3
RO1S4
RO1S5
RO1S6
8965
RO10
RO12
RO12
RO10
RO11
RO10
RO11
RO10
RO10
RO10
9999
9999
9999
R10
R12
R12
Application Data
Coils Duty: Hoist Duty—H4 Intermittent
Voltage Range: AC coils only; +10%, –15% of nominal
Burden Inrush 76 VA, Sealed 27 VA
Approvals
UL Component Recognized: File E78351, CCN NLDX2
CSA Certified: File LR60905, Class 3211 04
Table 17.108: How to Order
To Order Specify: Catalog Number
Class Number
Type Number
Voltage and Frequency
Class Type Voltage and
Frequency
8695 RO10 V02
CP1 CP10 Discount
Schedule
www.schneider-electric.us
17-36 © 2012 Schneider Electric
All Rights Reserved
17 NEMA DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Thermal Overload
Relays—NEMA Style
Solid-State Overload Relay, Motor Logic™ Plus
Class 9065 / Refer to Catalog 9065CT9701
Motor Logic Plus—Class 9065
The Motor Logic Plus solid-state overload relay is
separately powered and fully programmable. It is designed
to protect 3-phase AC motor applications, 200–480 Vac or
600 Vac. The SSOLR has one Form C relay output rated
for 300 Vac maximum.
jMust use 150:5 external current transformer, purchased separately.
kMust use 300:5 external current transformer, purchased separately.
lMust use 600:5 external current transformer, purchased separately.
Example
Form B 4 2
Motor Logic Plus overload relay with a current range of
6–27 A and modifications to add communication module
for an open style starter package.
Lug-Lug Kit
This kit can be field installed on separately mounted
Motor Logic Plus overload relays.
Software Kit
Solutions software program allows an IBM PC compatible
computer (with Windows 95 or greater) to communicate
with a Motor Logic Plus overload relay connected to an
RS-485 network using Modbus protocol.
Communication Module
This module allows the Motor Logic Plus overload relay to
support RS-485 electrical communications standards. Up
to 99 Motor Logic Plus overload relays can be controlled
and monitored from one remote personal computer.
Motor Logic Plus
Table 17.109: Motor Logic Plus
Class 9065 SP Solid-State Overload Relay $ Price
200 to 480 V 600 V Current Range
SPB4
SPC4
SP14
SP24
SP34
SP44j
SP54k
SP64l
SPB6
SPC6
SP16
SP26
SP36
SP46j
SP56k
SP66l
0.5–2.3 A
2.0–9.0 A
6.0–27.0 A
10.0–45.0 A
20.0–90.0 A
60.0–135.0 A
120.0–270.0 A
240.0–540.0 A
957.00
Table 17.110: Forms for factory addition to 8536
Open Style only
Alpha Character
BMotor Logic Plus Overload Relay
First Digit Current Ranges
2
3
4
5
6
7
8
9
0.5–2.3 A
2.0–9.0 A
6.0–27.0 A
10.0–45.0 A
20.0–90.0 A
60.0–135.0 A
120.0–270.0 A
240.0–540.0 A
Second Digit Modifications
0
2
4
6
No modification for 200–480 V
Add communication module for 200–480 V
No modification for 600 V
Add communication module for 600 V
Table 17.111: Lug-Lug Kit
For Use With Parts Kit
Description
Class 9999
Type $ Price
Class & Type NEMA Size
8536 SA-SH 1–6 Lug-Lug Kit MLPL 80.00
9065 SP 1–6
Table 17.112: Software Kit
For Use With Parts Kit
Description
Class 9999
Type $ Price
Class & Type NEMA Size
8536 SA–SH 1–6 Software Kit MLPS 1295.00
9065 SP
Table 17.113: Communication Module
For Use With Parts Kit
Description
Class 9999
Type $ Price
Class & Type NEMA Size
8536 SA-SH
1–6
Modbus
Communication
Module
MB22 171.00
9065 SP
Table 17.114: How to Order
To Order Specify: Catalog Number
Class Number
Type Number
Class Type
9999 AC04
Table 17.115: Full Voltage Controllers Only
Classes 8502, 8536, 8538, 8539, 8702, 8736, 8738, 8739, 8810, 8811 and 8812
Factory Modifications Enclosure
Type Form NEMA Size
00 0 1 2 3 4 5 6 7
Overload
Relays
Non-Compensated Bimetallic Overload Relays
Single Phase:
Types SB–SD (Sizes 0–2)bAny B1 35.60 35.60 35.60 ——— —
Polyphase:
Two Element—For 2 Phase Only
Types SB–SD (Sizes 0–2) Any B1 35.60 35.60 35.60 ——— —
Three Element
Types SB–SD (Sizes 0–2)
Type SG (Size 5)
Type SH (Size 6)
Any
Any
Any
B2
B2
B2
35.60
35.60
35.60
35.60
35.60
a
Ambient Compensated Bimetallic Overload Relays
Three Element
Types SB–SD (Sizes 0–2)
Types SE–SF (Sizes 3 & 4)
Type SG (Size 5)
Type SH (Size 6)
1, 4, 7, 9, 12
Any
Any
Any
B
Y59
B
B
64.00
64.00
64.00
64.00
64.00
64.00
64.00
a
Overload Relays—General
Modify Size 3 Type SE starters with melting alloy overload
relays to accept Type FB quick trip or SB slow trip thermal units
Any Y81 ———— N/C —— —
Substitute 9999 SO4 isolated alarm contact (N.O.)
on melting alloy overload relay Any Y342 179.00 179.00 179.00 179.00 179.00 179.00
179.00
c
179.00 a
Substitute 9999 SO5 isolated alarm contact (N.C.)
on melting alloy overload relay Any Y344 179.00 179.00 179.00 179.00 179.00 179.00
179.00
c
179.00 a
aSize 7 uses a solid state overload relay as standard. See Class 8536 for complete details.
bSingle phase bimetallic overload relays for Type S Sizes 0–2 require two (2) thermal units per starter.
cFor Classes 8736, 8738 and 8739 Type SG, consult Schneider Electric CCC at (1-888-778-2733).
CP1 Discount
Schedule

Navigation menu