Modicon M340
automation platform
Catalog
2011
0/3
Modicon M340
automation platform
Product data website .................................... 0/4
chapter 1:
Processor modules, power supply modules,
single-rack and multi-rack congurations........... 1/1
chapter 2:
I/O modules, application-specic modules,
quick wiring adapters.................................... 2/1
chapter3:
Communication........................................... 3/1
chapter 4:
Software.................................................... 4/1
chapter 5:
Connection interfaces, regulated switch mode
power supplies, Human/Machine Interfaces ........ 5/1
chapter 6:
“Ruggedized” Modicon M340 modules ........... 6/1
chapter 7:
Services .................................................... 7/1
General contents
0/4
1. On the home page, click on the “Products and Services” tab.
2. From the drop-down menu select “Products”.
1
2
1
Go online to www.schneider-electric.com for technical
information about products listed in this catalog, including:
To learn more about Modicon M340 automation platform
solutions, follow these steps...
2
0/5
> Specifications > Dimensions > References
> Curves > Links to user guides and CAD files
3 From the
“Products”
page, click on
“Automation
Hardware and
Software”,
then click on
“PLCs, PAC and
Distributed I/O”.
3
3
3 From the “PLCs,
PAC and Distributed
I/O” page, click on
“Modicon M340 PAC”.
4
4
5 From the product
details page, see
“Overview”,
“Product Selector”
and “Documents &
Downloads”.
5
5
5
0/6
1
2
3
4
5
6
7
8
9
10
1/1
1.1 - Processor modules
Selection guide ..................................................1/2
Introduction
b ....................................................1/4
Description
b .....................................................1/5
Memory structure .
b ...............................................1/6
Memory cards .
v ...............................................1/6
Application security
v ............................................1/6
Modifying the program in online mode
v ..............................1/6
References
b ....................................................1/7
1.2 - Power supply modules
Introduction, description, functions
b ..................................1/8
References
b ....................................................1/9
1.3 - Single-rack conguration
Introduction, description, functions
b .................................1/10
References
b ...................................................1/11
1.4 - Multi-rack conguration
Introduction, description
b .........................................1/12
References
b ...................................................1/13
“Ruggedized” modules .......................... see page 6/1
Processor modules, power supply
modules, single-rack and
multi-rack congurations
Contents chapter 1
1
2
3
4
5
6
7
8
9
10
1/2
Selection guide Modicon M340
automation platform
Modicon M340 processors
Modicon M340 platform for Unity Pro software offer BMX3410 Standard processor BMX3420 Performance processors BMX3420 Performance processors (continued)
Racks Number of racks 2 (with 4, 6, 8 or 12 slots) 4 (with 4, 6, 8 or 12 slots) 4 (with 4, 6, 8 or 12 slots)
Max. number of slots
(excluding power supply module)
24 48 48
I/O In-rack discrete I/O (1) 512 channels (modules with 8, 16, 32 or 64
channels)
1024 channels (modules with 8, 16, 32 or 64
channels)
1024 channels (modules with 8, 16, 32 or 64 channels)
In-rack analog I/O (1) 128 channels (modules with 2, 4, 6 or 8
channels)
256 channels (modules with 2, 4, 6 or 8
channels)
256 channels (modules with 2, 4, 6 or 8 channels)
Distributed I/O Limited depending on the type of medium: on Ethernet Modbus/TCP network via network
module (63 devices with I/O Scanning function), on Modbus link (32 devices)
Limited depending on the type of medium: on CANopen bus (63 devices), on Ethernet Modbus/TCP network via network module (63 devices with I/O Scanning
function), on Modbus link (32 devices)
In-rack application-
specic channels
No. of channels (counter, motion
control, serial link)
20 max. 36 max. 36 max.
Counter (1) BMXEHC0200 2-channel (60 kHz) or BMXEHC0800 8-channel (10 kHz) modules BMXEHC0200 2-channel (60 kHz) or BMXEHC0800 8-channel (10 kHz) modules
Motion control (1) BMXMSP0200 2-channel PTO (Pulse Train Output) modules for servo drives BMXMSP0200 2-channel PTO (Pulse Train Output) modules (200 kHz) for servo drives
MFB (Motion Function Block) library (for drives or
servo drives on CANopen bus)
MFB (Motion Function Block) library (for drives or
servo drives on CANopen bus)
Serial link (process or RTU) (1) BMXNOM0200 2-channel module or BMXNOR0200H module with 1 RTU serial channel BMXNOM0200 2-channel module or BMXNOR0200H module with 1 RTU serial channel
Process control, programmable
loops
Process control EFB library Process control EFB library
Integrated
communication ports
Ethernet Modbus/TCP network 1 x 10BASE-T/100BASE-TX
(Modbus/TCP, BOOTP/DHCP, FDR client, e-mail notication, class B10 standard Web server)
CANopen master bus 1 (63 slaves, 50 to 1000 Kbps, class M20) (2) 1 (63 slaves, 50 to 1000 Kbps, class M20) (2)
Serial link (process or RTU) 1 in RTU/ASCII Modbus master/slave mode or in Character mode (non-isolated RS232/RS485,
0.3 to 38.4 Kbps)
1 in RTU/ASCII Modbus master/slave mode or in Character mode (non-isolated RS232/RS485, 0.3 to 38.4
Kbps)
USB port 1 programming port (PC terminal) or HMI connection port 1 programming port (PC terminal) or HMI connection port
Communication
modules
(1)
Ethernet network Max. no. 2 2 2
Type of module BMXNOE0100/0110 or BMXNOC0401 network modules or BMXNOR0200H module with 1
Ethernet RTU channel
BMXNOE0100/0110 or BMXNOC0401 network modules or BMXNOR0200H module with 1 Ethernet RTU channel
AS-Interface
bus
Max. no. 2 4 4
Type of module BMXEIA0100 master module BMXEIA0100 master module
Internal memory
capacity
Internal user RAM 2048 KB 4096 KB 4096 KB
Program, constants and symbols 1792 KB 3584 KB 3584 KB
Located/unlocated data 128 KB 256 KB 256 KB
Memory card capacity
(on processor)
Backup of program, constants and
symbols
8 MB as standard 8 MB as standard
Hosting and display of user web pages (3) (3)
File storage 8 or 128 MB (according to BMXRMSpp8MPF
option card)
8 or 128 MB (according to BMXRMSpp8MPF option card)
Application structure Master task 1 1
Fast task 1 1
Event tasks 32 64 64
No. of K instructions
executed per ms
100% Boolean 5.4 Kinstructions/ms 8.1 Kinstructions/ms 8.1 Kinstructions/ms
65% Boolean + 35% mounted arithmetic
4.2 Kinstructions/ms 6.4 Kinstructions/ms 6.4 Kinstructions/ms
Rack power supply 24 V c isolated, 24 to 48 V c isolated or 100 to 240 V a power supply module 24 V c isolated, 24 to 48 V c isolated or 100 to 240 V a power supply module
Modicon M340 processor BMXP341000 BMXP342000 BMXP3420102 BMXP342020 BMXP3420302
Page 1/7 1/7
(1) The maximum values for the number of discrete I/O, analog I/O, counter/motion control/serial link channels and the number of networks are not cumulative
(they are limited by the maximum number of slots in the conguration, 1 rack: 11, 2 racks: 23, 3 racks: 35 and 4 racks: 47.
(3) User web pages with BMXNOE0110 Ethernet FactoryCast module (12 MB available).
(2) BMXP3420102/20302 processors can be used to customize conguration of the device Boot Up procedure compatible with CANopen third-party products.
Requires Unity Pro software, version u V4.1.
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
1/3
Modicon M340 platform for Unity Pro software offer BMX3410 Standard processor BMX3420 Performance processors BMX3420 Performance processors (continued)
Racks Number of racks 2 (with 4, 6, 8 or 12 slots) 4 (with 4, 6, 8 or 12 slots) 4 (with 4, 6, 8 or 12 slots)
Max. number of slots
(excluding power supply module)
24 48 48
I/O In-rack discrete I/O (1) 512 channels (modules with 8, 16, 32 or 64
channels)
1024 channels (modules with 8, 16, 32 or 64
channels)
1024 channels (modules with 8, 16, 32 or 64 channels)
In-rack analog I/O (1) 128 channels (modules with 2, 4, 6 or 8
channels)
256 channels (modules with 2, 4, 6 or 8
channels)
256 channels (modules with 2, 4, 6 or 8 channels)
Distributed I/O Limited depending on the type of medium: on Ethernet Modbus/TCP network via network
module (63 devices with I/O Scanning function), on Modbus link (32 devices)
Limited depending on the type of medium: on CANopen bus (63 devices), on Ethernet Modbus/TCP network via network module (63 devices with I/O Scanning
function), on Modbus link (32 devices)
In-rack application-
specic channels
No. of channels (counter, motion
control, serial link)
20 max. 36 max. 36 max.
Counter (1) BMXEHC0200 2-channel (60 kHz) or BMXEHC0800 8-channel (10 kHz) modules BMXEHC0200 2-channel (60 kHz) or BMXEHC0800 8-channel (10 kHz) modules
Motion control (1) BMXMSP0200 2-channel PTO (Pulse Train Output) modules for servo drives BMXMSP0200 2-channel PTO (Pulse Train Output) modules (200 kHz) for servo drives
MFB (Motion Function Block) library (for drives or
servo drives on CANopen bus)
MFB (Motion Function Block) library (for drives or
servo drives on CANopen bus)
Serial link (process or RTU) (1) BMXNOM0200 2-channel module or BMXNOR0200H module with 1 RTU serial channel BMXNOM0200 2-channel module or BMXNOR0200H module with 1 RTU serial channel
Process control, programmable
loops
Process control EFB library Process control EFB library
Integrated
communication ports
Ethernet Modbus/TCP network 1 x 10BASE-T/100BASE-TX
(Modbus/TCP, BOOTP/DHCP, FDR client, e-mail notication, class B10 standard Web server)
CANopen master bus 1 (63 slaves, 50 to 1000 Kbps, class M20) (2) 1 (63 slaves, 50 to 1000 Kbps, class M20) (2)
Serial link (process or RTU) 1 in RTU/ASCII Modbus master/slave mode or in Character mode (non-isolated RS232/RS485,
0.3 to 38.4 Kbps)
1 in RTU/ASCII Modbus master/slave mode or in Character mode (non-isolated RS232/RS485, 0.3 to 38.4
Kbps)
USB port 1 programming port (PC terminal) or HMI connection port 1 programming port (PC terminal) or HMI connection port
Communication
modules
(1)
Ethernet network Max. no. 2 2 2
Type of module BMXNOE0100/0110 or BMXNOC0401 network modules or BMXNOR0200H module with 1
Ethernet RTU channel
BMXNOE0100/0110 or BMXNOC0401 network modules or BMXNOR0200H module with 1 Ethernet RTU channel
AS-Interface
bus
Max. no. 2 4 4
Type of module BMXEIA0100 master module BMXEIA0100 master module
Internal memory
capacity
Internal user RAM 2048 KB 4096 KB 4096 KB
Program, constants and symbols 1792 KB 3584 KB 3584 KB
Located/unlocated data 128 KB 256 KB 256 KB
Memory card capacity
(on processor)
Backup of program, constants and
symbols
8 MB as standard 8 MB as standard
Hosting and display of user web pages (3) (3)
File storage 8 or 128 MB (according to BMXRMSpp8MPF
option card)
8 or 128 MB (according to BMXRMSpp8MPF option card)
Application structure Master task 1 1
Fast task 1 1
Event tasks 32 64 64
No. of K instructions
executed per ms
100% Boolean 5.4 Kinstructions/ms 8.1 Kinstructions/ms 8.1 Kinstructions/ms
65% Boolean + 35% mounted arithmetic
4.2 Kinstructions/ms 6.4 Kinstructions/ms 6.4 Kinstructions/ms
Rack power supply 24 V c isolated, 24 to 48 V c isolated or 100 to 240 V a power supply module 24 V c isolated, 24 to 48 V c isolated or 100 to 240 V a power supply module
Modicon M340 processor BMXP341000 BMXP342000 BMXP3420102 BMXP342020 BMXP3420302
Page 1/7 1/7
(1) The maximum values for the number of discrete I/O, analog I/O, counter/motion control/serial link channels and the number of networks are not cumulative
(they are limited by the maximum number of slots in the conguration, 1 rack: 11, 2 racks: 23, 3 racks: 35 and 4 racks: 47.
(3) User web pages with BMXNOE0110 Ethernet FactoryCast module (12 MB available).
(2) BMXP3420102/20302 processors can be used to customize conguration of the device Boot Up procedure compatible with CANopen third-party products.
Requires Unity Pro software, version u V4.1.
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
1/4
I/O:
pages 2/2 and 2/14 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Processor modules
Introduction
The robust Modicon M340 automation platform includes both: Standard
processors, BMXP341000, and Performance processors, BMXP342pppp. These
processors manage single-rack or multi-rack PAC stations whose slots can be
equipped with:
Discrete I/O modules
b
Analog I/O modules
b
Communication modules: Ethernet Modbus/TCP network, AS-Interface actuator/
b
sensor buses and RTU (Remote Terminal Unit)
Application-specic modules: counter, axis control and serial link
b
The ve processors offered have different memory capacities, processing speeds,
number of I/O and number and type of communication ports.
In addition, depending on the model, they offer a maximum (non-cumulative) of:
512 to 1024 discrete I/O v
128 to 256 analog I/O v
20 to 36 application-specic channels (1) (process counter, motion control and v
serial link, or RTU)
0 to 3 Ethernet Modbus/TCP or Ethernet/IP v networks (with or without
integrated port and 2 network modules maximum)
4 “Full Extended master” AS-Interface V3 actuator/sensor buses, prole M4.0 v
Depending on the model, Modicon M340 processors include:
A 10BASE-T/100BASE-TX Ethernet Modbus/TCP port
b
A CANopen machine and installation bus port
b
A Modbus
b or Character mode serial link port
Each processor has a USB TER port (for connecting a programming terminal or a
Magelis XBTGT/GK/GTW, GTW HMI, or STU/STO HMI terminal) and is supplied
with a memory card used for:
Backing up the application (program, symbols and constants) v
Activating a standard Web server for the Transparent Ready v class B10
integrated Ethernet port (depending on the model)
This memory card can be replaced by another type of memory card (to be ordered
separately) that supports:
Backing up the application and activation of the standard Web server (same as
b
other card)
An 8 MB or 128 MB storage area, depending on the option card, for storing
b
additional data organized in a le system (directories and sub-directories)
Design and setup of Modicon M340 applications
To set up Modicon M340 automation platform processors, you need one of
the following:
Unity
b Pro Small programming software
Unity Pro Medium, Large, Extra Large or XLS Safety programming software
b
identical to that used to set up Modicon Premium and Modicon Quantum
automation platforms
Depending on requirements, you may also need:
Unity EFB toolkit software for developing EF and EFB libraries in C language v
Unity SFC View software for viewing and diagnostics of applications written in v
Sequential Function Chart (SFC) or Grafcet language
The function block software libraries provide Modicon M340 processors with the
processing capability required to meet the needs of specializt applications in the
following areas:
Process control via programmable control loops (EF and EFB libraries)
b
Motion control with multiple independent axis functions (MFB
b (Motion Function
Block) library). The axes are controlled by Altivar 312/71 variable speed drives or
Lexium 05/32 servo drives connected on the CANopen machine and installation bus.
BMXP3420102/20302 processors with integrated CANopen bus are compatible with Unity Pro
version u 4.1. Both these processors can be used to customize conguration of the device Boot
Up procedure compatible with CANopen third-party products.
(1) Maximum number of application-specic channels per station. Only the application-specic
channels actually congured in the Unity application count.
I/O, communication and
application-specic
modules
BMXP34processor
AC or DC power supply
Modicon M340 automation platform
Introduction
For severe environments, see the
“ruggedized” Modicon M340 parts
on pages 6/2 to 6/9.
1
2
3
4
5
6
7
8
9
10
1/5
I/O:
pages 2/2 and 2/14 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Processor modules
Description: BMXP341000/2000/20102 processors
BMXP341000/2000/20102 Standard and Performance single-format processors
include the following features:
1 Safety screw for locking the module in its slot (marked 0) in the rack
2 Display block is comprised of 5 or 7 LEDs, depending on the model:
RUN LED (green): processor in operation (program execution) v
ERR LED (red): incorrect processor or system operation detected v
I/O LED (red): incorrect I/O module operation detected v
SER COM LED (yellow): activity on the Modbus v serial link
CARD ERR LED (red): memory card missing or inoperative v
CAN RUN LED (green): integrated CANopen bus operational ( vBMXP3420102
model only)
CAN ERR LED (red): incorrect integrated CANopen bus operation detected v
(BMXP3420102 model only)
3 Mini B USB connector for a programming terminal (or a Magelis XBTGT/GK/
GTW, GTW HMI, STU/STO HMI terminal (1))
4 Slot equipped with its Flash memory card for backing up the application (an LED,
located above this slot, indicates recognition of or access to the memory card)
5 RJ45 connector for the Modbus serial link or Character mode link
(RS 232C/RS 485, 2-wire, non-isolated)
In addition, for model BMXP3420102:
6 9-way SUB-D connector for the integrated CANopen master bus
Description: BMXP342020/20302 processors with integrated
Ethernet Modbus/TCP port
BMXP342020/20302 Performance single-format processors include the
following features:
1 Safety screw for locking the module in its slot (marked 0) in the rack
2 Display block is comprised of 8 or 10 LEDs, depending on the model:
RUN LED (green): processor in operation (program execution) v
ERR LED (red): incorrect processor or system operation detected v
I/O LED (red): incorrect I/O module operation detected v
SER COM LED (yellow): activity on the Modbus serial link v
CARD ERR LED (red): memory card missing or inoperative v
ETH ACT LED (green): activity on the Ethernet Modbus/TCP network v
ETH STS LED (green): Ethernet Modbus/TCP network status v
ETH 100 LED (red): Ethernet Modbus/TCP data rate (10 or 100 Mbps) v
CAN RUN LED (green): integrated CANopen bus operational ( vBMXP3420302
model only)
CAN ERR LED (red): incorrect integrated CANopen bus operation detected v
(BMXP3420302 model only)
3 Mini B USB connector for a programming terminal (or a Magelis XBTGT/GK/
GTW, GTW HMI and STU/STO HMI terminal (1))
4 Slot equipped with its Flash memory card for backing up the application (an LED,
located above this slot, indicates recognition of or access to the memory card)
5 RJ45 connector for connection to the 10BASE-T/100BASE-TX Ethernet Modbus/
TCP network
In addition, depending on the model:
6 BMXP342020 processor: an RJ45 connector for the Modbus serial link or
Character mode link (RS 232C/RS 485, 2-wire, non-isolated)
7 BMXP3420302 processor: a 9-way SUB-D connector for the integrated CANopen
master bus
On the back panel: 2 rotary switches for selecting the IP address assignment
method for the module.
USB terminal port
The USB port 3 offering a useful data rate of 12 Mbps, is compatible with the Unity
Pro programming software, the OPC Factory Server (OFS) and Magelis XBTGT/
GK/GTW, GTW HMI and STU/STO HMI terminals (1).
BMXP34 processors can be connected to a USB bus is comprised of several
peripheral devices. However:
Only one processor can be connected to the USB bus
b
No device on the USB bus can be controlled by the PAC (modem, printer)
b
BMXP3420102
BMXP341000/2000
BMXP3420302
7
2
3
5
1
4
5
2
3
1
4
6
2
3
5
1
4
BMXP342020
6
2
3
5
1
4
Description
(1) Magelis XBTGT/GK/GTW, GTW HMI and STU/STO
HMIGraphic terminals with USB port and Vijeo Designer
conguration software version u 4.5. Please consult our
“Human Machine Interfaces” catalog
1
2
3
4
5
6
7
8
9
10
1/6
I/O:
pages 2/2 and 2/14 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Processor modules
Memory structure
Memory cards
BMXRMS008MP memory card (supplied as standard)
Modicon M340 processors come standard with an SD (Secure Digital) type Flash
memory card, BMXRMS008MP. This card is used for backing up the two memory
areas on the processor module's internal RAM:
Program, symbols and comments area, that contains the executable binary code
b
and the IEC source code of the application program for the program part
Constants area, that contains the constant data located by address
b
The data is backed up automatically when the PAC is turned off. Likewise,
restoration of data is transparent to the user, on return of power.
Capacity of the “backup area” on the memory card: 1792 KB for the BMXP341000
Standard processor, 3584 KB for BMXP342pppp Performance processors.
Processors with an integrated Ethernet port, BMXP342020/20302, have an
additional 2 MB memory area specically for “Standard Web services”
(Transparent Ready B10) (see page 3/14).
The BMXRMS008MP memory card is formatted by Schneider Electric and supplied
with each processor. It is referenced as a replacement part.
BMXRMS008MPF/128MPF optional memory cards
Performance processors, BMXP342pppp, can accept a BMXRMS008MPF or
BMXRMS128MPF optional memory card in place of the standard memory card. In
addition to the features of the standard card, this card also provides a “le storage
area” with a maximum capacity of 8 MB (for the BMXRMS008MPF card) or 128 MB
(for the BMXRMS128MPF card).
This “le storage area” enables:
Any user-dened Microsoft Word
b ®, Excel®, PowerPoint® or Acrobat Reader®
document (for example, maintenance manuals, diagrams. etc.) to be received
via FTP
Additional data (for example: production data, manufacturing recipes, etc.) to be
b
stored via EFB user function blocks
Unity Pro programming software helps the application designer manage the
structure and memory space on the Modicon M340 automation platform.
Application security
If necessary, it is possible to prohibit access to the application (in terms of reading
and modifying the program) by only loading the executable code in the PAC.
Additionally, a memory protection bit, set in conguration mode, is also available to
help prevent any program modication (via the programming terminal or downloading).
For Unity Pro V5.0 and later versions, the user has function blocks to help secure
intellectual property by means of a signature that can be loaded and stored in the
M340 processor module's Flash memory card. The code is not executed if the
signature is not present.
Modifying the program in online mode
As with the Modicon Premium and Quantum platforms (with Unity Pro software), the
online program modication function is available on the Modicon M340 with the
option of adding or modifying the program code and data in different places in the
application in a single modication session. This helps to ensure that the
modication is homogenous and consistent with the controlled process.
A dedicated memory area of the application internal RAM authorizes these program
modication or addition sessions, while supporting the structuring of the application
program in several, reasonably-sized sections.
1
2
3
4
5
6
7
8
9
10
1/7
I/O:
pages 2/2 and 2/14 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Processor modules
References
Modicon M340 processors
I/O capacity Max. no. of network
and bus modules
Integrated
communication
ports
Compatibility with
Unity Pro
software
Reference Weight
kg
Standard BMXP3410, 2 racks
512 discrete I/O
128 analog I/O 20
application-specic
channels
2048 KB integrated (internal
user memory)
2 Ethernet networks
2 AS-Interface buses
1 Modbus serial link Version u 3.0 BMXP341000 0.200
Performance BMXP3420, 4 racks
1024 discrete I/O
256 analog I/O 36
application-specic
channels
4096 KB integrated (internal
user memory)
2 Ethernet networks
4 AS-Interface buses
1 Modbus serial link Version u 3.0
BMXP342000 0.200
1 Modbus serial link
1 CANopen bus
Version u 4.1 BMXP3420102 0.210
1 Modbus serial link
1 Ethernet network
Version u 3.0 BMXP342020 0.205
1 Ethernet network
1 CANopen bus
Version u 4.1 BMXP3420302 0.215
Memory cards
Description Processor compatibility Capacity Reference Weight
kg
Flash memory cards
(optional) (2)
BMXP342000
BMXP3420102
BMXP342020
BMXP3420302
8 MB + 8 MB le
storage
BMXRMS008MPF 0.002
8 MB + 128 MB le
storage
BMXRMS128MPF 0.002
Separate parts
Description Use Length Reference Weight
kg
From To
Terminal port/
USB cordsets
Mini B USB port
on the Modicon
M340 processor
Type A USB port on:
- PC terminal
- Magelis XBTGT/GK/
GTW, GTW HMI, STU/
STO HMIGraphic terminal
1.8 m BMXXCAUSBH018 0.065
4.5 m BMXXCAUSBH045 0.110
Replacement parts
Description Use Processor
compatibility
Reference Weight
kg
8 MB standard Flash
memory card
Supplied as standard with each
processor. Used for:
Backing up the program, constants, -
symbols and data
Activation of class B10 Web server-
BMXP341000
BMXP342020
BMXP3420102/20302
BMXRMS008MP 0.002
(1) BMXP3420102/20302 processors, combined with Unity Pro software version u 4.1 can be used to customize conguration
of the device Boot Up procedure compatible with CANopen third-party products.
(2) Memory cards for BMXP342pppp processors, to replace the standard memory card, used for:
Backing up the program, constants, symbols and data-
Activation of class B10 Web server-
File storage-
BMXP341000
BMXP3420102
BMXP3420302
BMXP342000
BMXP342020
BMXRMS008/128MPF
BMXXCAUSBH0pp
1
2
3
4
5
6
7
8
9
10
1/8
I/O:
pages 2/2 and 2/14 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Power supply modules
Introduction,
description,
functions
Introduction
BMXCPSpppp power supply modules provide the power supply for each
BMXXBPpp00 Modicon M340 rack and the modules installed on it.
The Modicon M340 power supply module offer includes:
Three power supply modules for DC line supplies:
b
24 V v c isolated power supply module, BMXCPS2010
24 to 48 V v c isolated power supply module, BMXCPS3020
125 V v c power supply module, BMXCPS3540T (extended operating
temperature -25° to +70°C)
Two power supply modules for AC line supplies:
b
100 to 240 V va, 20 W power supply module, BMXCPS2000
100 to 240 V va, 36 W power supply module, BMXCPS3500
Description
The power supply module is selected according to:
The electrical line supply: 24 V b c, 48 V c, 125 V c or 100 to 240 V a
The required power (see the power consumption table on page b7/16)
(1)
BMXCPSpppp power supply modules feature the following:
1 Display block is comprised of:
OK LED (green), lit if rack voltages are present and correct v
24 V LED (green), lit when the sensor voltage is present v
(BMXCPS2000/3500/3540T AC power supply modules only)
2 Pencil-point RESET push button for a cold restart of the application
3 2-way connector that can take a removable terminal block (cage clamp
or
spring-type)
for connecting the alarm relay
4 5-way connector that can take a removable terminal block (cage clamp
or
spring-type)
for connecting the following:
c v or a line supply
Protective earth ground v
Dedicated 24 V v c power supply for the input sensors (for
BMXCPS2000/3500/3540T AC power supply modules only)
Included with each power supply module:
Set of two cage clamp removable terminal blocks (5-way and 2-way) b
BMXXTSCPS10
To be ordered separately (if necessary):
Set of two spring-type removable terminal blocks (5-way and 2-way) b
BMXXTSCPS20
Functions
Alarm relay
The alarm relay incorporated in each power supply module has a volt-free contact,
accessible on the front panel, on the 2-way connector.
This relay is operated is as follows:
In normal operation, with the PAC in RUN, the alarm relay is energized and its
contact is closed (state 1).
The relay de-energizes and its associated contact opens (state 0) whenever the
application stops, even partially, due to any of the following:
Required interlock is not satised
b
Incorrect rack output voltages
b
Supply voltage missing or otherwise inoperative
b
___________________________________________________________________________
(1) This power consumption calculation for the rack can also be performed by the Unity Pro
programming software.
1
3
4
2
1
2
3
4
5
6
7
8
9
10
1/9
I/O:
pages 2/2 and 2/14 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Power supply modules
Functions,
references
Functions (continued)
RESET push button
The power supply module in each rack has a RESET button on the front panel that, when pressed, triggers an
initialization sequence on the processor and the modules in the rack it supplies.
Pressing this push button triggers a sequence of service signals, that is the same as that for:
A power break, when the push button is pressed
b
A power-up, when the push button is released
b
In terms of the application, these operations represent a cold start (forcing the I/O modules to state 0 and
initializing the processor).
Sensor power supply
BMXCPS2000/3500 AC power supply modules and BMXCPS3540T DC power supply modules have an
integrated 24 V c supply for powering the input sensors.
Connection to this 24 V c sensor power supply is via the 5-way connector on the front panel.
The available power depends on the power supply module (0.45 A or 0.9 A).
References
Each BMXXBPpp00 rack requires a power supply module. These modules are inserted in the rst two slots of
each rack (marked CPS).
The power required to supply each rack depends on the type and number of modules installed in the rack. It is
therefore necessary to draw up a power consumption table for each rack to determine which BMXCPSppp0
power supply module is correct for each rack (see page 7/16).
Power supply modules (1)
Line supply Available power (2) Nominal current Reference Weight
kg
3.3 V c (3) 24 V c rack
(3)
24 V c
sensors (4)
Total 24 V c rack
(3)
24 V c
isolated
8.3 W 16.8 W 16.8 W 0.7A BMXCPS2010 0.290
24 to 48 V c
isolated
15 W 31.2 W 31.2 W 1.3A BMXCPS3020 0.340
100 to 150 V c 15 W 31.2 W 21.6 W 36 W (5) 1.3A BMXCPS3540T
(5)
0.340
100 to 240 V a 8.3 W 16.8 W 10.8 W 20 W 0.7A BMXCPS2000 0.300
15 W 31.2 W 21.6 W 36 W 1.3A BMXCPS3500 0.360
Separate part
Description Type Composition Reference Weight
kg
Set of 2 removable
connectors
Spring-type One 5-way terminal block and
one 2-way terminal block
BMXXTSCPS20 0.015
Replacement part
Description Type Composition Reference Weight
kg
Set of 2 removable
connectors
Cage clamp One 5-way terminal block and
one 2-way terminal block
BMXXTSCPS10 0.020
(1) Include a set of 2 cage clamp removable connectors. Spring-type connectors available separately under reference
BMXXTSCPS20.
(2) The sum of the power consumed on each voltage (3.3 V c and 24 V c) must not exceed the available power of the module.
See the power consumption table on page 7/16.
(3) 3.3 V c and 24 V c rack voltages for powering modules in the Modicon M340 PAC rack.
(4) 24 V c sensor voltage for powering the input sensors (voltage available via the 2-way removable connector on the front panel).
(5) Extended operating temperature -25° to +70°C (with power derating at extreme temperatures: 27 W between -25° and 0°C and
between 60° and 70°C).
BMXCPS2010/3020
BMXCPS2000/3500
1
2
3
4
5
6
7
8
9
10
1/10
I/O:
pages 2/2 and 2/14 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
4 7 4
153
6
BMXXBP0600 rack with 6 slots
Modicon M340
automation platform
Single-rack conguration
Introduction
BMXXBPpp00 racks are the basic element in Modicon M340 single-rack and
multi-rack congurations. They perform the following functions:
Mechanical function: they are used to install the modules in a PAC station (power
b
supply, processor, discrete, analog and application-specic I/O). These racks can be
mounted on a panel, plate or DIN rail:
Inside enclosures v
On machine frames v
Electrical function: the racks incorporate a Bus X (proprietary bus). They are used to:
b
Distribute the power supplies required for each module in the same rack v
Distribute data and service signals for the entire PAC station v
Hot swap modules during operation v
Description
BMXXBPpp00 racks are available in 4, 6, 8 or 12-slot versions and feature:
1 Metal frame that performs the following functions:
Holds the Bus X electronic card and helps to protect it against EMI and ESD type -
interference
Holds the modules-
Gives the rack mechanical rigidity-
2 Earth ground terminal for grounding the rack
3 4 holes (big enough for M6 screws) for mounting the rack on a frame
4 2 mounting points for the shielding connection bar
5 Tapped holes to take the locking screw on each module
6 Connector for a rack expansion module, marked XBE
7 40-way female ½ DIN connectors forming the electrical connection between the rack
and each module, marked CPS, 00 to 11 (The rack is delivered with each connector
covered. The cover is removed before inserting the module)
8 Slots for anchoring the module pins
To be ordered separately:
A BMXXSPpp00 cable shielding connection kit, used to help protect against
electrostatic discharge when connecting the shielding on cordsets for connecting:
Analog, counter and motion control modules v
A Magelis v XBT operator interface to the processor (via BMXXCAUSBH0pp
shielded USB cable)
The BMXXSPpp00 shielding connection kit is comprised of:
9 Metal bar that takes the clamping rings and the grounding terminal
10 Two sub-bases to be mounted on the rack
11 Earth grounding terminal
12 Not included in the shielding connection kit, the STBXSP30p0 clamping rings
(sold in lots of 10, cross-section 1.5 to 6 mm2 or 5 to 11 mm2)
Function
Addressing modules in a single-rack conguration (1)
Each rack requires a power supply module and a processor module.
Installing the modules in the rack:
The power supply module occupies the vCPS slot
The processor module is installed in slot v00
I/O modules and application-specic modules are installed from slot v01 to slot:
03- for a 4-slot rack
05- for a 6-slot rack
07- for an 8-slot rack
11- for a 12-slot rack
___________________________________________________________________________
(1) For a multi-rack conguration with a BMXXBE1000 rack expansion module (XBE slot), see
page 1/12.
CPS 01 02 03 04 05 06 0700
Example of installation with 8-slot rack
Introduction,
description,
function
8
2
XBE
BMXXSPpp00 cable shielding connection kit
10 9 12 11 10
1
2
3
4
5
6
7
8
9
10
1/11
Racks
Description Type of module
to be inserted
No. of slots
(1)
Reference Weight
kg
Racks BMXCPS power supply,
BMXP34processor, I/O
modules, communication
modules and application-
specic modules (counter,
motion control and serial)
4
BMXXBP0400
0.630
6
BMXXBP0600
0.790
8
BMXXBP0800
0.950
12
BMXXBP1200
1.270
(1) Number of slots taking the processor module, I/O modules, communication modules and
application-specic modules (excluding power supply module).
Accessories
Description For use with Reference Weight
kg
Shielding connection kits is
comprised of:
1 metal bar-
2 support sub-bases-
1 grounding terminal-
BMXXBP0400 rack
BMXXSP0400
0.280
BMXXBP0600 rack
BMXXSP0600
0.310
BMXXBP0800 rack
BMXXSP0800
0.340
BMXXBP1200 rack
BMXXSP1200
0.400
Spring clamping rings
Sold in lots of 10
Cables, cross-section 1.5 to 6 mm2STBXSP3010 0.050
Cables, cross-section 5 to 11 mm2STBXSP3020 0.070
Protective covers (replacement
parts)
Sold in lots of 5
Unoccupied slots on
BMXXBPpp00 rack
BMXXEM010 0.005
BMXXBP1200
Modicon M340
automation platform
Single-rack conguration
References
BMXXBP0400
BMXXBP0800
STBXSPpp00 + STBXP30p0
BMXXBP0600
I/O:
pages 2/2 and 2/14 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
1
2
3
4
5
6
7
8
9
10
1/12
I/O:
pages 2/2 and 2/14 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Introduction,
description
Modicon M340
automation platform
Multi-rack conguration
Composition of a multi-rack conguration
Multi-rack congurations are made up of standard BMXXBPpp00 racks.
They feature:
2 racks maximum for a station with
b BMXP341000 processor
4 racks maximum for a station with
b BMXP342pp0 processor
Each rack is equipped with:
BMXCPS1 ppppp power supply
BMXXBE10002 rack expansion module This module, inserted in the right-hand
end of the rack (XBE slot, see page 1/10) does not occupy rack slots 00 to 11
(4, 6, 8 or 12 slots are still available)
BMXXBE10003 rack expansion modules connected to each other by Bus X
cordsets
Bus X
Racks, distributed on the Bus X, are connected to each other by Bus X extension
cordsets 3 with a combined length of 30 m maximum.
Racks are connected in a daisy chain using BMXXBCpp0K (1) Bus X extension
cordsets connected to the two 9-way SUB-D connectors 7 and 8 on the front panels
of the BMXXBE1000 rack expansion modules 2.
Line terminators 4
Both expansion modules at the ends of the daisy chain require a line terminator 4
TSXTLYEX on the unused 9-way SUB-D connector.
Note: The processor module is positioned in the rack at address 0. However, in a Bus X daisy
chain, the order of the racks has no effect on operation. For example, the order of the daisy chain
can be 0-1-2-3, 2-0-3-1 or 3-1-2-0, etc.
Description
The front panel of the BMXXBE1000 rack expansion module features:
5 Safety screw for locking the module in its slot (at the far right-hand end of the rack)
6 Display block with 5 LEDs:
RUN LED (green): module in operation b
COL LED (red): several racks have the same address, or rack address 0 does not b
contain the BMXP34ppp0 processor module
LEDs 0, 1, 2 and 3 (green): rack address 0, 1, 2 or 3 b
7 9-way female SUB-D connector, marked Bus X, for the incoming Bus X cordset 3
connected to the upstream rack, or if it is the rst rack, for the A/ line terminator
included in the TSXTLYEX 4 pack
8 9-way female SUB-D connector, marked Bus X, for the outgoing Bus X cordset 3
to the downstream rack, or if it is the last rack, for the /B line terminator included in
the TSXTLYEX 4 pack
On the right-hand side panel
A ap for accessing the 3 rack addressing micro-switches: 0 to 3.
Installation rules for BMXXBPppp0 racks
Rules for installing racks in enclosures (see our website www.schneider-electric.com).
___________________________________________________________________________
(1) BMXXBCpp0K extension cordsets, length 0.8 m, 1.5 m, 3 m, 5 m or 12 m, with angled
connectors or TSXCBYp08K extension cordsets, length 1 m, 3 m, 5 m, 12 m, 18 m or 28 m,
with straight connectors.
1
1
4
4 3
2
5
6
7
8
4
1
2
3
4
5
6
7
8
9
10
1/13
I/O:
pages 2/2 and 2/14 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Rack expansion
Description Use Reference Weight
kg
Modicon M340
rack expansion
module
Standard module for mounting in each rack
(XBE slot) and used to interconnect:
- Up to 2 racks with BMXP341000 processor module
- Up to 4 racks with BMXP342pppp processor module
BMXXBE1000
0.178
Modicon M340
rack expansion kit
Complete kit for 2-rack conguration is comprised of:
2 BMXXBE1000 rack expansion modules -
1 BMXXBC008K extension cordset, length 0.8 m -
1 TSXTLYEX line terminator (set of 2) -
BMXXBE2005
0.700
Cordsets and connection accessories
Description Use Composition Type of
connector
Length Reference Weight
kg
Bus X extension
cordsets
combined length
30 m max.
Between 2
BMXXBE1000
rack expansion
modules
2 x 9-way SUB-D
connectors
Angled 0.8 m
BMXXBC008K
0.165
1.5 m
BMXXBC015K
0.250
3 m
BMXXBC030K
0.420
5 m
BMXXBC050K
0.650
12 m
BMXXBC120K
1.440
Straight 1 m
TSXCBY010K
0.160
3 m
TSXCBY030K
0.260
5 m
TSXCBY050K
0.360
12 m
TSXCBY120K
1.260
18 m
TSXCBY180K
1.860
28 m
TSXCBY280K
2.860
Cable reel Length of cable to
be tted with
TSXCBYK9
connectors
Cable with
ends with ying
leads, 2 line testers
100 m
TSXCBY1000
12.320
Description Use Composition Sold in
lots of
Reference Weight
kg
Line terminators Required on the 2
BMXXBPppp0
modules located
at either end of
the daisy chain
2 x 9-way SUB-D
connectors marked A/ and /B
2
TSXTLYEX
0.050
Bus X
straight
connectors
For
TSXCBY1000
cables
2 x 9-way SUB-D
straight connectors
2
TSXCBYK9
0.080
Connector
assembly kit
Fitting
TSXCBYK9
connectors
2 crimping pliers,
1 pen
(1)
TSXCBYACC10
(1) To t the connectors on the cable, you will also need a wire stripper, a pair of scissors and a digital ohmmeter.
BMXXBE1000
BMXXBCpppK
TSXTLYEX
Modicon M340
automation platform
Multi-rack conguration
References
1
2
3
4
5
6
7
8
9
10
1/14
1
2
3
4
5
6
7
8
9
10
2/1
2.1 - Discrete I/O modules
Selection guide ..................................................2/2
Introduction, description
b ..........................................2/8
Connections
b ...................................................2/9
Functions
b .....................................................2/10
Complementary Specications
b ....................................2/11
References
b ..................................................2/12
2.2 - Analog I/O modules
Selection guide .................................................2/14
Introduction
b ...................................................2/18
Description
b ...................................................2/19
Connections, combinations
b .......................................2/20
Complementary Specications
b ....................................2/21
References
b ...................................................2/22
Accessories
b ..................................................2/23
2.3 - Programmable process control
Introduction, functions
b ..........................................2/24
Setup
b. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2/25
2.4 - Distributed I/O
Selection guide .................................................2/26
2.5 - Application-specic modules and
MFB motion control
Counter modules
b
Introduction, description
v .......................................2/28
Functions
v ..................................................2/29
References
v .................................................2/31
Motion control module
b
Introduction, description
v .......................................2/32
Operation, references
v .........................................2/33
MFB motion control
b
Introduction, functions
v .........................................2/34
Setup
v ......................................................2/35
2.6 - Quick wiring adapters for Modicon M340
Introduction
b ...................................................2/36
Compact
b modules/Modicon M340 modules compatibility . . . . . . . . . . . . . . 2/36
I/O modules, application-specic
modules, quick wiring adapters
Contents chapter 2
1
2
3
4
5
6
7
8
9
10
2/2
Applications Input module
8 channels
16-channel input modules 16-channel input modules
Connection via cage clamp, screw clamp or spring-type removable block terminal Connection via cage clamp, screw clamp or spring-type removable block terminal
Type a c a or c a c
Voltage 200 to 240 V 24 V 48 V 24 V (a or c) 48 V 100 to 120 V 125 V
Current per channel 10.4 mA
(for U = 220 V to 50 Hz)
3.5 mA 2.5 mA 3 mA (a or c) 5 mA 2.4 mA
Modularity
(Number of channels and
commons)
8 isolated inputs and
1 common
16 isolated inputs and
1 common
16 isolated inputs and
1 common
Connection Via 20-way cage clamp, screw clamp or spring-type removable terminal block
BMXFTB2000/2010/2020
Via BMXFTB2000/2010/2020 20-way cage clamp, screw clamp or spring-type removable block terminal
Isolated inputs IEC/EN 61131-2 conformity Type 2 Type 3 Type 1 Type 1 (a) Type 3
Logic Positive (sink) Negative (source) (c) Positive (sink)
Type of input Capacitive Current sink Resistive Capacitive Current sink
Sensor compatibility
IEC/EN 60947-5-2
2-wire a2-wire c, 3-wire c PNP any type 2-wire c/a, 3-wire c PNP or
NPN any type
2-wire a
Sensor power supply
(ripple included)
170 to 264 V 19 to 30 V 38 to 60 V 19 to 30 V c
20 to 26 V a40 to 52 V 85 to 132 V 88 to 150 V
Protection of inputs Use one 0.5 A fast-blow fuse per group of channels Use one 0.5 A fast-blow fuse per group of channels
Maximum dissipated power 4.73 W 2.5 W 3.6 W 3 W 4 W 3.8 W 8.5 W (at 40°C)
Operating temperature 0 to 60°C 0 to 60°C -25 to 70°C
Compatibility with
installation help system
TeSys Quickt
– –
Compatibility with
pre-wired system
Modicon
Telefast ABE7
Passive connection
sub-bases
– –
Adaptor sub-bases with
relays
– –
References BMXDAI0805 BMXDDI1602 BMXDDI1603 BMXDAI1602 BMXDAI1603 BMXDAI1604 BMXDDI1604T
Page 2/12 2/12
Modicon M340
automation platform
Discrete I/O modules
Input modules
Selection guide
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
2/3
Applications Input module
8 channels
16-channel input modules 16-channel input modules
Connection via cage clamp, screw clamp or spring-type removable block terminal Connection via cage clamp, screw clamp or spring-type removable block terminal
Type a c a or c a c
Voltage 200 to 240 V 24 V 48 V 24 V (a or c) 48 V 100 to 120 V 125 V
Current per channel 10.4 mA
(for U = 220 V to 50 Hz)
3.5 mA 2.5 mA 3 mA (a or c) 5 mA 2.4 mA
Modularity
(Number of channels and
commons)
8 isolated inputs and
1 common
16 isolated inputs and
1 common
16 isolated inputs and
1 common
Connection Via 20-way cage clamp, screw clamp or spring-type removable terminal block
BMXFTB2000/2010/2020
Via BMXFTB2000/2010/2020 20-way cage clamp, screw clamp or spring-type removable block terminal
Isolated inputs IEC/EN 61131-2 conformity Type 2 Type 3 Type 1 Type 1 (a) Type 3
Logic Positive (sink) Negative (source) (c) Positive (sink)
Type of input Capacitive Current sink Resistive Capacitive Current sink
Sensor compatibility
IEC/EN 60947-5-2
2-wire a2-wire c, 3-wire c PNP any type 2-wire c/a, 3-wire c PNP or
NPN any type
2-wire a
Sensor power supply
(ripple included)
170 to 264 V 19 to 30 V 38 to 60 V 19 to 30 V c
20 to 26 V a40 to 52 V 85 to 132 V 88 to 150 V
Protection of inputs Use one 0.5 A fast-blow fuse per group of channels Use one 0.5 A fast-blow fuse per group of channels
Maximum dissipated power 4.73 W 2.5 W 3.6 W 3 W 4 W 3.8 W 8.5 W (at 40°C)
Operating temperature 0 to 60°C 0 to 60°C -25 to 70°C
Compatibility with
installation help system
TeSys Quickt
– –
Compatibility with
pre-wired system
Modicon
Telefast ABE7
Passive connection
sub-bases
– –
Adaptor sub-bases with
relays
– –
References BMXDAI0805 BMXDDI1602 BMXDDI1603 BMXDAI1602 BMXDAI1603 BMXDAI1604 BMXDDI1604T
Page 2/12 2/12
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
2/4
Applications 32 or 64-channel high-density input modules 16 or 32-channel mixed I/O module
Connection via 40-way connectors with pre-assembled cordsets Connection via cage clamp, screw clamp or spring-type removable block terminal Connection via 40-way connector with pre-
assembled cordsets
Type c c c and a (outputs only) c
Voltage 24 V Inputs: 24 V
Solid-state outputs: 24 V
Inputs: 24 V c
Relay outputs: 24 V c or 24 to 240 V aInputs: 24 V
Solid-state outputs: 24 V
Current per channel Inputs 2.5 mA 1 mA 3.5 mA 3.5 mA 2.5 mA
Outputs 0.5 A 2 A (c or a) 0.1 A
Modularity
(Number of channels and
commons)
32 isolated inputs and
2 commons
64 isolated inputs and
4 commons
8 isolated inputs and 1 common,
8 isolated outputs and 1 common
16 isolated inputs and 1 common,
16 isolated outputs and 1 common
Connection Via one 40-way connector Via two 40-way connectors Via BMXFTB2000/2010/2020
20-way cage clamp, screw clamp or spring-type removable terminal block
Via one 40-way connector
Isolated inputs IEC/EN 61131-2 conformity Type 3 Non-IEC Type 3
Logic Positive (sink) Positive (sink) Positive (sink)
Type of input Current sink Current sink
Sensor compatibility
IEC/EN 60947-5-2
2-wire c, 3-wire c PNP any type 2-wire c, 3-wire c PNP any type
Sensor power supply
(ripple included)
19 to 30 V 19 to 30 V
Protection of inputs Use one 0.5 A fast-blow fuse per group of channels Use one 0.5 A fast-blow fuse per group of channels
Isolated outputs Fallback – Congurable output fallback, continuous monitoring of output control and resetting of outputs in case of detected internal fault
IEC/EN 61131-2 conformity Yes
Protection Overvoltage, short circuit and overload protection Overvoltage, short circuit and overload protection
Logic – Positive Positive
Preactuator power supply
(ripple included)
19 to 30 V 19 to 30 V c
24 to 240 V a
19 to 30 V
Output fuse protection Use a 2 A fast-blow fuse Use a 12 A fast-blow fuse Use a 2 A fast-blow fuse
Maximum dissipated power 3.9 W 4.3 W 3.7 W 3.1 W 4 W
Operating temperature 0 to 60°C 0 to 60°C
Compatibility with
installation help system
TeSys Quickt
LU9 G02 splitter boxes (8 motor starters) and BMXFCCpp1/pp3 pre-assembled cordsets.
See pages 2/9 and 2/13.
LU9 G02 splitter boxes (8 motor starters) and
BMXFCCpp1/pp3 pre-assembled cordsets.
See pages 2/9 and 2/13.
Compatibility with pre-wired
system
Modicon Telefast ABE7
Passive connection
sub-bases
Depending on model, 8 or 16-channel passive sub-bases, with or without LED, with common or
2 terminals per channel.
See pages 5/2 and 5/8.
Depending on model, 8 or 16-channel passive
sub-bases, with or without LED, with common or 2
terminals per channel. See pages 5/2 and 5/8.
Adaptor sub-bases with
relays
Depending on model, active sub-bases with solid state or electromagnetic relays (mounted or
removable), 16 channels, with common or 2 terminals per channel (screw or spring-type
connection).
See pages 5/2 and 5/8.
Depending on model, active sub-bases with solid
state or electromagnetic relays (mounted or
removable)
16 channels, with common or 2 terminals per
channel (screw or spring-type connection).
See pages 5/2 and 5/8.
References BMXDDI3202K BMXDDI6402K BMXDDM16022 BMXDDM16025 BMXDDM3202K
Page 2/12 2/13
Modicon M340
automation platform
Discrete I/O modules
Input modules and mixed I/O modules
Selection guide (continued)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
2/5
Applications 32 or 64-channel high-density input modules 16 or 32-channel mixed I/O module
Connection via 40-way connectors with pre-assembled cordsets Connection via cage clamp, screw clamp or spring-type removable block terminal Connection via 40-way connector with pre-
assembled cordsets
Type c c c and a (outputs only) c
Voltage 24 V Inputs: 24 V
Solid-state outputs: 24 V
Inputs: 24 V c
Relay outputs: 24 V c or 24 to 240 V aInputs: 24 V
Solid-state outputs: 24 V
Current per channel Inputs 2.5 mA 1 mA 3.5 mA 3.5 mA 2.5 mA
Outputs 0.5 A 2 A (c or a) 0.1 A
Modularity
(Number of channels and
commons)
32 isolated inputs and
2 commons
64 isolated inputs and
4 commons
8 isolated inputs and 1 common,
8 isolated outputs and 1 common
16 isolated inputs and 1 common,
16 isolated outputs and 1 common
Connection Via one 40-way connector Via two 40-way connectors Via BMXFTB2000/2010/2020
20-way cage clamp, screw clamp or spring-type removable terminal block
Via one 40-way connector
Isolated inputs IEC/EN 61131-2 conformity Type 3 Non-IEC Type 3
Logic Positive (sink) Positive (sink) Positive (sink)
Type of input Current sink Current sink
Sensor compatibility
IEC/EN 60947-5-2
2-wire c, 3-wire c PNP any type 2-wire c, 3-wire c PNP any type
Sensor power supply
(ripple included)
19 to 30 V 19 to 30 V
Protection of inputs Use one 0.5 A fast-blow fuse per group of channels Use one 0.5 A fast-blow fuse per group of channels
Isolated outputs Fallback – Congurable output fallback, continuous monitoring of output control and resetting of outputs in case of detected internal fault
IEC/EN 61131-2 conformity Yes
Protection Overvoltage, short circuit and overload protection Overvoltage, short circuit and overload protection
Logic – Positive Positive
Preactuator power supply
(ripple included)
19 to 30 V 19 to 30 V c
24 to 240 V a
19 to 30 V
Output fuse protection Use a 2 A fast-blow fuse Use a 12 A fast-blow fuse Use a 2 A fast-blow fuse
Maximum dissipated power 3.9 W 4.3 W 3.7 W 3.1 W 4 W
Operating temperature 0 to 60°C 0 to 60°C
Compatibility with
installation help system
TeSys Quickt
LU9 G02 splitter boxes (8 motor starters) and BMXFCCpp1/pp3 pre-assembled cordsets.
See pages 2/9 and 2/13.
LU9 G02 splitter boxes (8 motor starters) and
BMXFCCpp1/pp3 pre-assembled cordsets.
See pages 2/9 and 2/13.
Compatibility with pre-wired
system
Modicon Telefast ABE7
Passive connection
sub-bases
Depending on model, 8 or 16-channel passive sub-bases, with or without LED, with common or
2 terminals per channel.
See pages 5/2 and 5/8.
Depending on model, 8 or 16-channel passive
sub-bases, with or without LED, with common or 2
terminals per channel. See pages 5/2 and 5/8.
Adaptor sub-bases with
relays
Depending on model, active sub-bases with solid state or electromagnetic relays (mounted or
removable), 16 channels, with common or 2 terminals per channel (screw or spring-type
connection).
See pages 5/2 and 5/8.
Depending on model, active sub-bases with solid
state or electromagnetic relays (mounted or
removable)
16 channels, with common or 2 terminals per
channel (screw or spring-type connection).
See pages 5/2 and 5/8.
References BMXDDI3202K BMXDDI6402K BMXDDM16022 BMXDDM16025 BMXDDM3202K
Page 2/12 2/13
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
2/6
Applications 32 or 64-channel high-density output modules 16-channel output modules 8 or 16-channel output modules
Connection via 40-way connectors with pre-assembled cordsets Connection via cage clamp, screw clamp or spring-type removable block terminal
Type c transistor c transistor a triac c relay c/a relay
Voltage 24 V 24 V 100 to 240 V 100 to 150 V 24 V c, 24 to 240 V a
Current per channel 0.1 A 0.5 A 0.6 A 0.3 A (Ith) 2 A (Ith)
Modularity
(Number of channels and
commons)
32 outputs and 2 commons with overvoltage,
short-circuit and overload protection
64 outputs and 4 commons with overvoltage,
short-circuit and overload protection
16 outputs and 1 commons with overvoltage,
short-circuit and overload protection
16 outputs
and 4 commons
8 outputs,
without common
16 outputs and 2 commons
Connection Via one 40-way connector Via two 40-way connectors Via BMXFTB2000/2010/2020 20-way cage clamp, screw clamp or spring-type removable block terminal
Isolated outputs Fallback Congurable output fallback, continuous monitoring of output control and resetting of outputs in
case of detected internal fault
Congurable output fallback, continuous monitoring
of output control and resetting of outputs in case of
detected internal fault
Congurable output fallback
IEC/EN 61131-2 conformity Yes Yes Yes
Protection Yes Yes
Logic Positive Positive (source) Negative (sink)
Preactuator power supply
(ripple included)
19 to 30 V c19 to 30 V 100 to 240 V 100 to 150 V 19 to 30 V c
24 to 240 V a
Output fuse protection Use one 2 A fast-blow fuse per group of channels Use one 6.3 A
fast-blow fuse per group of channels
Use one 3 A fast-blow
fuse per group of
channels
Use one 0.5 A, 250 V DC
fast-blow fuse on each
relay
Use one 3 A fast-blow
fuse on each channel
Use one 12 A fast-blow
fuse on each group of
channels
Maximum dissipated power 3.6 W 6.85 W 4 W 2.26 W 3.17 W 2.7 W 3 W
Operating temperature 0 to 60°C 0 to 60°C -25 to 70°C 0 to 60°C
Compatibility with
installation help system
TeSys Quickt
LU9 G02 splitter boxes (8 motor starters) and BMXFCCpp1/pp3 pre-assembled cordsets.
See pages 2/9 and 2/13.
Compatibility with
pre-wired system
Modicon TelefastABE7
Passive connection
sub-bases
Depending on model, passive sub-bases with 8 or 16 channels, with or without LED, with
common or with 2 terminals per channel.
See pages 5/2 and 5/8.
Adaptor sub-bases with
relays
Depending on model, active sub-bases with solid state or electromagnetic relays (mounted or
removable). 16 channels with 1 common or 2 terminals per channel, screw or spring-type
connection.
See pages 5/2 and 5/8
References BMXDDO3202K BMXDDO6402K BMXDDO1602 BMXDDO1612 BMXDAO1605 BMXDRA0804T BMXDRA0805 BMXDRA1605
Page 2/12 2/12
Modicon M340
automation platform
Discrete I/O modules
Output modules
Selection guide (continued)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
2/7
Applications 32 or 64-channel high-density output modules 16-channel output modules 8 or 16-channel output modules
Connection via 40-way connectors with pre-assembled cordsets Connection via cage clamp, screw clamp or spring-type removable block terminal
Type c transistor c transistor a triac c relay c/a relay
Voltage 24 V 24 V 100 to 240 V 100 to 150 V 24 V c, 24 to 240 V a
Current per channel 0.1 A 0.5 A 0.6 A 0.3 A (Ith) 2 A (Ith)
Modularity
(Number of channels and
commons)
32 outputs and 2 commons with overvoltage,
short-circuit and overload protection
64 outputs and 4 commons with overvoltage,
short-circuit and overload protection
16 outputs and 1 commons with overvoltage,
short-circuit and overload protection
16 outputs
and 4 commons
8 outputs,
without common
16 outputs and 2 commons
Connection Via one 40-way connector Via two 40-way connectors Via BMXFTB2000/2010/2020 20-way cage clamp, screw clamp or spring-type removable block terminal
Isolated outputs Fallback Congurable output fallback, continuous monitoring of output control and resetting of outputs in
case of detected internal fault
Congurable output fallback, continuous monitoring
of output control and resetting of outputs in case of
detected internal fault
Congurable output fallback
IEC/EN 61131-2 conformity Yes Yes Yes
Protection Yes Yes
Logic Positive Positive (source) Negative (sink)
Preactuator power supply
(ripple included)
19 to 30 V c19 to 30 V 100 to 240 V 100 to 150 V 19 to 30 V c
24 to 240 V a
Output fuse protection Use one 2 A fast-blow fuse per group of channels Use one 6.3 A
fast-blow fuse per group of channels
Use one 3 A fast-blow
fuse per group of
channels
Use one 0.5 A, 250 V DC
fast-blow fuse on each
relay
Use one 3 A fast-blow
fuse on each channel
Use one 12 A fast-blow
fuse on each group of
channels
Maximum dissipated power 3.6 W 6.85 W 4 W 2.26 W 3.17 W 2.7 W 3 W
Operating temperature 0 to 60°C 0 to 60°C -25 to 70°C 0 to 60°C
Compatibility with
installation help system
TeSys Quickt
LU9 G02 splitter boxes (8 motor starters) and BMXFCCpp1/pp3 pre-assembled cordsets.
See pages 2/9 and 2/13.
Compatibility with
pre-wired system
Modicon TelefastABE7
Passive connection
sub-bases
Depending on model, passive sub-bases with 8 or 16 channels, with or without LED, with
common or with 2 terminals per channel.
See pages 5/2 and 5/8.
Adaptor sub-bases with
relays
Depending on model, active sub-bases with solid state or electromagnetic relays (mounted or
removable). 16 channels with 1 common or 2 terminals per channel, screw or spring-type
connection.
See pages 5/2 and 5/8
References BMXDDO3202K BMXDDO6402K BMXDDO1602 BMXDDO1612 BMXDAO1605 BMXDRA0804T BMXDRA0805 BMXDRA1605
Page 2/12 2/12
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
2/8
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Introduction,
description
Modicon M340
automation platform
Discrete I/O modules
Introduction
The Modicon M340 discrete I/O modules are standard modules occupying a
single slot on the rack. These modules are equipped with either of the following:
Connector for a screw or spring-type 20-way removable terminal block b
One or two 40-way connectors b
These discrete I/O modules can be used to meet multiple requirements, including:
Functions, AC or DC I/O, positive or negative logic b
Modularity, 8, 16, 32 or 64 channels per module b
The inputs receive signals from the sensors and perform the following functions:
Acquisition b
Adaptation b
Electrical isolation b
Filtering b
Protection against interference signals b
The outputs memorize commands issued by the processor to enable control of the
preactuators via the decoupling and amplication circuits.
Description
BMXDpI/DpO/DRA discrete I/O modules are standard format (1 slot). They have a
case, that helps to ensure IP 20 protection of the electronics, and are locked into
position by a captive screw.
I/O modules connected via 20-way removable terminal block
Rigid body providing support and protection for the electronic card1
Module reference marking (a label is also visible on the right-hand side of the 2
module)
Channel status display block3
Connector taking the 20-way removable terminal block for connecting sensors or 4
preactuators
To be ordered separately:
BMXFTB201 p0 20-way removable terminal block (identication label supplied
with each I/O module) or a pre-assembled cordset with a 20-way removable
terminal block at one end and ying leads at the other (see page 2/9).
I/O modules connected via 40-way connector(s)
Rigid body providing support and protection for the electronic card1
Module reference marking (a label is also visible on the right-hand side of the 2
module)
Channel status display block3
One or two 40-way connectors (32 or 64 channels) 4 (1) for connecting sensors or
preactuators
With the 64-channel module, a push button that, with successive presses, 5
displays the state of channels 0 to 31 or 32 to 63 on the display block 3 (see
page 2/10)
To be ordered separately, depending on the type of module:
One or two pre-assembled cordset(s) with a 40-way connector (see page 2/9)
(1) Fujitsu FCN 40-way connector
1
3
4
2
32 and 64-channel modules for connection
via one or two 40-way connector(s)
5
1
3
4
2
Module for connection via 20-way removable terminal block
5
1
2
3
4
5
6
7
8
9
10
2/9
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
B
BA
A
Pre-assembled cordset with
20-way removable terminal block at one end and
ying leads at the other
Pre-assembled cordset with
40-way connector and two ends with ying leads
Example of connection to the TeSys Quickt installation help
system
Connections Modicon M340
automation platform
Discrete I/O modules
Connecting modules with removable terminal blocks
There are three types of 20-way removable terminal block:
Screw clamp terminal block b
Cage clamp terminal block b
Spring-type terminal block b
Each removable terminal block can accept:
Bare wires b
Wires equipped with bDZ5CE cable ends
A : One version of the removable terminal block is equipped with 3, 5 or 10 m cordsets
with color-coded ying leads (BMXFTWpp1). Use limited to voltages of y 48 V.
Cage clamp terminal blocks
The capacity of each terminal is:
Minimum: One 0.34 mm b2wire (AWG 22)
Maximum: One 1 mm b2 wire (AWG 18)
BMXFTB2000 cage clamp connectors are equipped with captive screws (maximum
tightening torque 0.5 N.m).
Screw clamp terminal blocks
The capacity of each terminal is:
Minimum: One or two 0.34 mm b2 wires (AWG 22)
Maximum: Two 1.5 mm b2 wires (AWG 15)
BMXFTB2010 screw clamp connectors are equipped with captive screws (maximum
tightening torque 0.5 N.m).
Spring terminals
The capacity of each terminal in the BMXFTB2020 spring-type terminal blocks is:
Minimum: One 0.34 mm b2 wire (AWG 22)
Maximum: One 1 mm b2 wire (AWG 18)
Connecting modules with 40-way connectors
Pre-assembled cordsets with 40-way connector at one end and ying leads at
the other
B : Pre-assembled cordsets can be used for easy direct wire-to-wire connection
between the I/O of modules with 40-way connectors1 and the sensors, preactuators
or intermediate terminal blocks.
These pre-assembled cordsets are comprised of:
At one end, a 40-way connector b2 with either of the following:
One sheath containing 20 wires with a cross-section of 0.34 mm -
2
(AWG 22)
(BMXFCWpp1)
Two sheaths -
3
, each containing 20 wires with a cross-section of 0.34 mm
2
(AWG 22) (BMXFCWpp3)
At the other end, color-coded ying leads b
4
conforming to standard DIN 47100.
Pre-assembled cordsets with 40-way connector and HE 10 connector(s)
C : Two types of cordset can be used for connecting the I/O of modules 1 with
40-way connectors to Modicon Telefast ABE7 rapid wiring connection and
adaptation interfaces, (see page 5/8).
These pre-assembled cordsets are comprised of:
At one end, a 40-way connector b2 with either of the following:
One sheath containing 20 wires ( - BMXFCCpp1)
Two sheaths -
3
each containing 20 wires (BMXFCCpp3)
At the other end, one or two HE 10 connectors b5.
Connection to TeSys Quickt system
D : 1 BMXDDI3202K/6402K input modules, BMXDDO3202K/6402K output
modules and BMXDDM3202K mixed I/O modules with 40-way connectors are
designed, among other things, for use in conjunction with the TeSys Quickt
mounting system via theLU9 G02 splitter module 6 (for 8 motor starters).
The splitter modules are easily connected using
7
BMXFCCpp1/pp3 pre-assembled
cordsets.
B
BA
A
Pre-assembled cordset with
40-way connectors and HE10 connectors for
Modicon Telefast ABE7 system
A
B
C
D
1
2
5
3
1
2
3
4
1
7
6
1
2
3
4
5
6
7
8
9
10
2/10
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Functions Modicon M340
automation platform
Discrete I/O modules
Functions (1)
The discrete I/O modules provide the following functions:
Hot swapping b: Due to their special integrated devices, I/O modules (including
application-specic modules) can be removed or added while the power is on.
I/O assignment b: The channels of discrete I/O modules are grouped into blocks of
4, 8 or 16 consecutive channels depending on the type of module. Each group of
channels can be assigned to a specic application task, namely master or fast.
Protection of DC inputs b: The 24 V c and 48 V c inputs are constant-current
type. This characteristic helps to limit the current consumed at the inputs.
Protection of DC outputs b: Active transistor outputs have overload, short-circuit,
reverse polarity and inductive over-voltage protection.
Reactivation of DC outputs b: If a detected fault has caused an output to trip, the
output can be reactivated using this parameter if no other detected terminal fault is
present. Reactivation is controlled by means of a group of 8 channels. It can be
programmed or automatic.
RUN/STOP b command: An input can be congured to control the RUN/STOP
changeover for the PAC.
Output fallback b: This parameter denes the fallback mode used by the DC
transistor outputs when the PAC stops. It can assume the “fallback” value at state 0
or state 1 for the corresponding group of 8 channels or the “maintain” value
representing the state of the outputs before the PAC stops.
I/O module diagnostics b: Each discrete I/O module is equipped with a display
block on the front panel centralizing the information necessary for module control,
diagnostics and maintenance.
Diagnostics via Unity Pro software:
Using the integrated diagnostics in Unity Pro programming software, this local
diagnostics on the module front panel is complemented by system diagnostics
based on predened screens at global hardware conguration level, module level
and channel level (see page 4/4).
Remote diagnostics using a web browser on a “Thin Client” PC:
In addition, the diagnostics described above can be performed remotely using a
simple web browser thanks to the standard web server integrated in the Modicon
M340 platform (processor with integrated Ethernet port or Ethernet module), using
the “ready-to-use” Rack Viewer function (see page 3/14).
Compatibility with 2-wire and 3-wire sensors b: The discrete input modules can
be used in conjunction with OsiSense XS inductive proximity sensors (for
compatibility, see page 7/10) and with OsiSense XU photo-electric sensors (for
compatibility, see page 7/8).
(1) For further information, please consult our website at www.schneider-electric.com.
Display block for module BMXDDO6402K
1
2
3
4
5
6
7
8
9
10
2/11
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Specications Modicon M340
automation platform
Discrete I/O modules
Complementary Specications
The following specications are specic to the discrete I/O modules listed in the
selection guide on pages 2/2 to 2/7.
DC input modules BMXDDI 16pp/1604T/3202K/6402K and BMXDAI1602
Input impedance at nominal voltage: 6.4 to 19.2 k b, depending on model
Reverse polarity: Protection for modules BMXDDI1602/1603/3202K b
Paralleling of inputs b(1), for modules BMXDDI1602/1603
Dielectric strength between group of channels: 500 V bc for modules
BMXDDI3202K/6402K
Temperature derating for module BMXDDI1604T: No derating up to 40°C, a b
maximum of 25% of inputs at state 1 at 70°C
AC input modules BMXDAI16pp/0805
Input frequency: 47 to 63 Hz b
Current peak on activation at nominal voltage: 5 to 240 mA depending on model b
Input impedance at nominal voltage and F = 55 Hz: 6 to 21 k b, depending on model
Triac output modules BMXDAO1605
Current via common: 2.4 A b
Current for 4 commons combined: 4.8 A b
DC transistor output modules BMXDDO16pp/3202K/6402K
Dielectric strength between groups of channels: 500 V bc for modules
BMXDDO3202K/6402K
Relay output modules BMXDRA080pp/1605
Protection against AC inductive overvoltage: Use an RC circuit or ZNO surge b
limiter appropriate to the voltage in parallel on each output.
Protection against DC inductive overvoltage: Use a discharge diode on each output. b
Mixed I/O relay module BMXDDM16025
Input impedance at nominal voltage: 6.8 k b
Dielectric strength between groups of inputs: 500 V bc
DC mixed I/O modules BMXDDM16022/3202K
Input impedance at nominal voltage: 6.8 to 9.6 k b, depending on model
Reverse polarity on the inputs: Protection b
Paralleling of outputs: Yes, for a maximum of 2 outputs for module BMXDDI16022 b
and a maximum of 3 outputs for module BMXDDI3202K
(1) This characteristic allows several inputs to be wired in parallel on the same module or on
different modules for input redundancy.
1
2
3
4
5
6
7
8
9
10
2/12
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
References Modicon M340
automation platform
Discrete I/O modules
Input modules and output modules
References
Discrete input modules (1)
Type of
current
Input voltage Connection via
(2)
IEC/EN
61131-2
conformity
No. of channels
(common)
Reference Weight
kg
c24 V (positive
logic)
Screw or spring-type 20-way
removable terminal block
Type 3 16 isolated inputs
(1 x 16)
BMXDDI1602 0.115
One 40-way connector Type 3 32 isolated inputs
(2 x 16)
BMXDDI3202K 0.110
Two 40-way connectors Non-IEC 64 isolated inputs
(4 x 16)
BMXDDI6402K 0.145
24 V (negative
logic)
Screw or spring-type 20-way
removable terminal block
Non-IEC 16 isolated inputs
(1 x 16)
BMXDAI1602 0.115
48 V (positive
logic)
Screw or spring-type 20-way
removable terminal block
Type 1 16 isolated inputs
(1 x 16)
BMXDDI1603 0.115
125 V (positive
logic)
Screw or spring-type 20-way
removable terminal block
16 isolated inputs
(1 x 16)
BMXDDI1604T 0.144
a24 V Screw or spring-type 20-way
removable terminal block
Type 1 16 isolated inputs
(1 x 16)
BMXDAI1602 0.115
48 V Screw or spring-type 20-way
removable terminal block
Type 3 16 isolated inputs
(1 x 16)
BMXDAI1603 0.115
100 to 120 V Screw or spring-type 20-way
removable terminal block
Type 3 16 isolated inputs
(1 x 16)
BMXDAI1604 0.115
200 to 240 V Screw or spring-type 20-way
removable terminal block
Type 2 8 isolated inputs
(1 x 8)
BMXDAI0805 0.152
Discrete output modules (1)
Type of
current
Output voltage Connection via
(2)
IEC/EN
61131-2
conformity
No. of channels
(common)
Reference Weight
kg
c
transistor
24 V/0.5 A
(positive logic)
20-way removable terminal
block, screw or spring-type
Yes 16 protected (3)
outputs
(1 x 16)
BMXDDO1602 0.120
24 V/0.5 A
(negative logic)
20-way removable terminal
block, screw or spring-type
16 protected (3)
outputs
(1 x 16)
BMXDDO1612 0.120
24 V/0.1 A
(positive logic)
One 40-way connector Yes 32 protected (3)
outputs
(2 x 16)
BMXDDO3202K 0.110
Two 40-way connectors Yes 64 protected (3)
outputs
(4 x 16)
BMXDDO6402K 0.150
a triac 100 to 240 20-way removable terminal
block, screw or spring-type
16 outputs
(4 x 4)
BMXDAO1605 0.140
c relay 100 to 150 V c/
0.3 A
20-way removable terminal
block, screw or spring-type
Yes 8 outputs BMXDRA0804T 0.178
c or a
relay
24 V c/2 A
24 to 240 V a/
2 A
20-way removable terminal
block, screw or spring-type
Yes 8 outputs
(without common)
BMXDRA0805 0.145
20-way removable terminal
block, screw or spring-type
Yes 16 outputs
(2 x 8)
BMXDRA1605 0.150
(1) Typical consumption: See the power consumption table on page 7/16.
(2) 64-channel modules have 2 connectors and therefore require 2 connection cables.
(3) Includes overvoltage, short-circuit and overload protection.
BMXDDI160pp
BMXDAIpppp
BMXDDI3202K BMXDDI6402K
BMXDDO16p2
BMXDDO3202K BMX DDO6402K
BMXDRA
0805/1605
1
2
3
4
5
6
7
8
9
10
2/13
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
References (continued)
Discrete mixed I/O modules (1)
Number of
I/O
Connection No. of input channels
(common)
No. of output
channels
(common)
IEC/EN
61131-2
conformity
Reference Weight
kg
16 Screw or
spring-type
20-way
removable
terminal block
8 (positive logic)
(1 x 8)
8, transistor
24 V c/0.5 A
(1 x 8)
Inputs,
type 3
BMXDDM16022 0.115
8, relay 24 V c or
24 to 240 V a
(1 x 8)
Inputs,
type 3
BMXDDM16025 0.135
32 One 40-way
connector
16 (positive logic)
(1 x 16)
16, transistor 24 V
c/0.1 A
(1 x 16)
Inputs,
type 3
BMXDDM3202K 0.110
Removable terminal blocks
Description For use with Type Reference Weight
kg
20-way removable terminal
blocks
For module with 20-way removable terminal block Cage clamp BMXFTB2000 0.093
Screw clamp BMXFTB2010 0.075
Spring BMXFTB2020 0.060
Pre-assembled cordsets for 16-channel I/O modules with removable terminal block
Description Composition Cross-
section
Length Reference Weight
kg
Pre-assembled cordsets
with one end with ying
leads for 16-channel I/O
modules
Operating voltage y 48 V
One 20-way spring-type removable
terminal block (BMXFTB2020) and
one end with color-coded ying
leads
0.324 mm23 m BMXFTW301 0.850
5 m BMXFTW501 1.400
10 m BMXFTW1001 2.780
Pre-assembled cordsets for 16, 32 and 64-channel I/O modules with 40-way connectors
Description No. of
sheaths
Composition Cross-
section
Length Reference Weight
kg
Pre-assembled cordsets
with one end with ying
leads
1 x 20
wires (16
channels)
One 40-way
connector and
one end with color-coded
ying leads
0.324 mm23 m BMXFCW301 0.820
5 m BMXFCW501 1.370
10 m BMXFCW1001 2.770
2 x 20
wires (32
channels)
(2)
One 40-way
connector and
two ends with color-
coded ying leads
0.324 mm23 m BMXFCW303 0.900
5 m BMXFCW503 1.490
10 m BMXFCW1003 2.960
Pre-assembled cordsets
for Modicon Telefast ABE7
sub-bases
1 x 20
wires (16
channels)
One 40-way connector
and one HE 10
connector
0.324 mm20.5 m BMXFCC051 0.140
1 m BMXFCC101 0.195
2 m BMXFCC201 0.560
3 m BMXFCC301 0.840
5 m BMXFCC501 1.390
10 m BMXFCC1001 2.780
2 x 20
wires (32
channels)
(2)
One 40-way connector
and two HE 10 connectors
0.324 mm20.5 m BMXFCC053 0.210
1 m BMXFCC103 0.350
2 m BMXFCC203 0.630
3 m BMXFCC303 0.940
5 m BMXFCC503 1.530
10 m BMXFCC1003 3.000
(1) Typical consumption: See the power consumption table on page 7/16.
(2) 64-channel modules have 2 connectors and therefore require 2 connection cables.
BMXDDM
1602pBMX DDM3202K
BMXFTB2p00
BMXFTWp01
BMXFCWp01
BMXFCCp01
BMXFCWp03
Modicon M340
automation platform
Discrete I/O modules
Mixed I/O modules, accessories
References (continued)
1
2
3
4
5
6
7
8
9
10
2/14
Selection guide Modicon M340
automation platform
Analog I/O modules
Input modules
Applications Analog inputs Analog inputs
Type of input Isolated low-level inputs, voltage, thermocouples, temperature probes, resistors Isolated high-level inputs Non-isolated high-level inputs Isolated high-level inputs
Type Multi-range Voltage/current
Range Voltage ± 40 mV, ± 80 mV, ± 160 mV, ± 320 mV, ± 640 mV, ± 1.28 V ± 10 V, 0 to 10 V, 0 to 5 V, 1..5 V, ± 5 V
Current 0 to 20 mA, 4 to 20 mA, ± 20 mA
Thermocouple
Temperature probe
Resistor
Thermocouples, type B, E, J, K, L, N, R, S, T, U
2, 3 or 4-wire temperature probes, type Pt100, JPt100, Pt1000, JPt1000, Ni100, Ni1000
(in accordance with DIN 43760) and Cu 10
2, 3 or 4-wire resistors, 400 or 4000
Modularity 4 inputs 8 inputs 4 inputs 8 inputs
Acquisition period 400 ms for the 4 inputs 400 ms for the 8 inputs Fast: 1 + (1 x no. of declared channels) ms
Default: 5 ms for the 4 channels
Fast: 1 + (1 x no. of declared channels) ms
Default: 9 ms for the 8 channels
Conversion time – –
Resolution 15 bits + sign 16 bits 15 bits + sign
Isolation Between channels 750 Vc300 Vc 300 Vc
Between channels and bus 1400 Vc1400 Vc
Between channels and earth
ground
750 Vc1400 Vc
Connection Directly to the module Via 40-way connector Via two 40-way connectors Via 20-way removable terminal block (screw or
spring-type) BMXFTB20p0
Via 28-way removable terminal block (spring-type)
BMXFTB2820
Via pre-assembled cordsets Cordsets with one end with color-coded ying leads
BMXFCWp01S (3 or 5 m long)
Cordsets with one end with color-coded ying leads
BMXFTWp01S (3 or 5 m long)
Cordsets with one end with color-coded ying leads
BMXFTWp08S (3 or 5 m long)
Compatibility with pre-wired
system
Modicon Telefast ABE7
Connection sub-base 4-channel sub-base for direct connection of 4 thermocouples plus connection
and provision of cold junction compensation.
See page 5/8
4-channel sub-base for direct connection of 4 inputs,
delivers and distributes 4 isolated power supplies.
See page 5/8
8-channel sub-base for direct connection of 8 current/voltage inputs. See page 5/8
Type of connection sub-base ABE7CPA412 ABE7CPA410 ABE7CPA02/03/31/31E ABE7CPA02/31/31E
Type of pre-assembled
cordsets
BMXFCApp2
(1.5, 3 or 5 m long)
BMXFCApp0
(1.5, 3 or 5 m long)
BMXFTApp0
(1.5 or 3 m long)
References BMXART0414 BMXART0814 BMXAMI0410 BMXAMI0800 BMXAMI0810
Page 2/22 2/22
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
2/15
Applications Analog inputs Analog inputs
Type of input Isolated low-level inputs, voltage, thermocouples, temperature probes, resistors Isolated high-level inputs Non-isolated high-level inputs Isolated high-level inputs
Type Multi-range Voltage/current
Range Voltage ± 40 mV, ± 80 mV, ± 160 mV, ± 320 mV, ± 640 mV, ± 1.28 V ± 10 V, 0 to 10 V, 0 to 5 V, 1..5 V, ± 5 V
Current 0 to 20 mA, 4 to 20 mA, ± 20 mA
Thermocouple
Temperature probe
Resistor
Thermocouples, type B, E, J, K, L, N, R, S, T, U
2, 3 or 4-wire temperature probes, type Pt100, JPt100, Pt1000, JPt1000, Ni100, Ni1000
(in accordance with DIN 43760) and Cu 10
2, 3 or 4-wire resistors, 400 or 4000
Modularity 4 inputs 8 inputs 4 inputs 8 inputs
Acquisition period 400 ms for the 4 inputs 400 ms for the 8 inputs Fast: 1 + (1 x no. of declared channels) ms
Default: 5 ms for the 4 channels
Fast: 1 + (1 x no. of declared channels) ms
Default: 9 ms for the 8 channels
Conversion time – –
Resolution 15 bits + sign 16 bits 15 bits + sign
Isolation Between channels 750 Vc300 Vc 300 Vc
Between channels and bus 1400 Vc1400 Vc
Between channels and earth
ground
750 Vc1400 Vc
Connection Directly to the module Via 40-way connector Via two 40-way connectors Via 20-way removable terminal block (screw or
spring-type) BMXFTB20p0
Via 28-way removable terminal block (spring-type)
BMXFTB2820
Via pre-assembled cordsets Cordsets with one end with color-coded ying leads
BMXFCWp01S (3 or 5 m long)
Cordsets with one end with color-coded ying leads
BMXFTWp01S (3 or 5 m long)
Cordsets with one end with color-coded ying leads
BMXFTWp08S (3 or 5 m long)
Compatibility with pre-wired
system
Modicon Telefast ABE7
Connection sub-base 4-channel sub-base for direct connection of 4 thermocouples plus connection
and provision of cold junction compensation.
See page 5/8
4-channel sub-base for direct connection of 4 inputs,
delivers and distributes 4 isolated power supplies.
See page 5/8
8-channel sub-base for direct connection of 8 current/voltage inputs. See page 5/8
Type of connection sub-base ABE7CPA412 ABE7CPA410 ABE7CPA02/03/31/31E ABE7CPA02/31/31E
Type of pre-assembled
cordsets
BMXFCApp2
(1.5, 3 or 5 m long)
BMXFCApp0
(1.5, 3 or 5 m long)
BMXFTApp0
(1.5 or 3 m long)
References BMXART0414 BMXART0814 BMXAMI0410 BMXAMI0800 BMXAMI0810
Page 2/22 2/22
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
2/16
Selection guide Modicon M340
automation platform
Analog I/O modules
Output modules and mixed I/O modules
Applications Analog Outputs Mixed analog I/O
Type of I/O Isolated high-level outputs Isolated high-level outputs High-level outputs
non-isolated
Non-isolated high-level inputs and outputs
Type Voltage/current Current Voltage/current
Range Voltage ± 10 V Inputs: ± 10 V, 0 to 10 V, 0 to 5 V, 1..5 V
Outputs: ± 10 V
Current 0 to 20 mA, 4 to 20 mA Inputs: 0 to 20 mA, 4 to 20 mA
Outputs: 0 to 20 mA, 4 to 20 mA
Modularity 2 outputs 4 outputs 8 outputs 4 inputs and 2 outputs
Acquisition period
(inputs)
Fast: 1 + (1 x no. of declared channels) ms
Default: 5 ms for the 4 channels
Conversion time
(outputs)
y 1 ms y 4 ms y 1 ms
Resolution Inputs 14 to 12-bit in U range
12-bit in I range
Outputs 15 bits + sign 12-bit in U range
11-bit in I range
Isolation Between channels: 750 V cBetween groups of input or output channels: 750 V c
Between channels and bus: 1400 V cBetween channels and bus: 1400 V c
Between channels and earth ground: 1400 V cBetween channels and earth ground: 1400 V c
Connection Directly to the module Via 20-way removable terminal block (screw or spring-type)
BMXFTB20p0
Via 20-way removable terminal block (screw or spring-type) BMXFTB20p0
Via pre-assembled cordsets Cordsets with one end with color-coded ying leads
BMXFTWp01S (3 or 5 m long)
BMXFTWp01S cordsets with one end with color-coded ying leads (3 or 5 m long)
Compatibility with pre-wired
system
Modicon Telefast ABE7
Connection sub-base 4-channel sub-base for direct connection
of 2/4 current/voltage outputs. See page 5/8
8-channel sub-base for direct
connection of
8 current/voltage inputs.
See page 5/8
Type of connection sub-base ABE7CPA21 ABE7CPA02
Type of pre-assembled
cordsets
BMXFCApp0
(1.5, 3 or 5 m long)
BMXFTApp2
(1.5 or 3 m long)
References BMXAMO0210 BMXAMO0410 BMXAMO0802 BMXAMM0600
Page 2/22 2/22
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
2/17
Applications Analog Outputs Mixed analog I/O
Type of I/O Isolated high-level outputs Isolated high-level outputs High-level outputs
non-isolated
Non-isolated high-level inputs and outputs
Type Voltage/current Current Voltage/current
Range Voltage ± 10 V Inputs: ± 10 V, 0 to 10 V, 0 to 5 V, 1..5 V
Outputs: ± 10 V
Current 0 to 20 mA, 4 to 20 mA Inputs: 0 to 20 mA, 4 to 20 mA
Outputs: 0 to 20 mA, 4 to 20 mA
Modularity 2 outputs 4 outputs 8 outputs 4 inputs and 2 outputs
Acquisition period
(inputs)
Fast: 1 + (1 x no. of declared channels) ms
Default: 5 ms for the 4 channels
Conversion time
(outputs)
y 1 ms y 4 ms y 1 ms
Resolution Inputs 14 to 12-bit in U range
12-bit in I range
Outputs 15 bits + sign 12-bit in U range
11-bit in I range
Isolation Between channels: 750 V cBetween groups of input or output channels: 750 V c
Between channels and bus: 1400 V cBetween channels and bus: 1400 V c
Between channels and earth ground: 1400 V cBetween channels and earth ground: 1400 V c
Connection Directly to the module Via 20-way removable terminal block (screw or spring-type)
BMXFTB20p0
Via 20-way removable terminal block (screw or spring-type) BMXFTB20p0
Via pre-assembled cordsets Cordsets with one end with color-coded ying leads
BMXFTWp01S (3 or 5 m long)
BMXFTWp01S cordsets with one end with color-coded ying leads (3 or 5 m long)
Compatibility with pre-wired
system
Modicon Telefast ABE7
Connection sub-base 4-channel sub-base for direct connection
of 2/4 current/voltage outputs. See page 5/8
8-channel sub-base for direct
connection of
8 current/voltage inputs.
See page 5/8
Type of connection sub-base ABE7CPA21 ABE7CPA02
Type of pre-assembled
cordsets
BMXFCApp0
(1.5, 3 or 5 m long)
BMXFTApp2
(1.5 or 3 m long)
References BMXAMO0210 BMXAMO0410 BMXAMO0802 BMXAMM0600
Page 2/22 2/22
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
2/18
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Introduction Modicon M340
automation platform
Analog I/O modules
Introduction
The product offering for the Modicon M340 Analog I/O modules features:
5 analog input modules: b
2 modules with 4 and 8 isolated channels, low-level voltage, thermocouples, v
Pt, JPt, Ni or Cu temperature probes and resistors, 15 bits + sign
BMXART0414/0814
1 module with 4 high-speed isolated analog channels, high-level voltage or v
current, 16 bits BMXAMI0410
2 modules with 8 high-speed non-isolated analog channels, high-level voltage v
or current, 15 bits + sign BMXAMI0800/0810
3 analog output modules: b
1 module with 2 isolated analog channels, high-level voltage or current, 15 bits v
+ sign BMXAMO0210
1 module with 4 isolated analog channels, high-level voltage or current, 15 bits v
+ sign BMXAMO0410
1 module with 8 non-isolated analog channels, high-level current, 15 bits + sign v
BMXAMO0802
1 mixed analog I/O module with 4 input channels and 2 output channels b
(non-isolated), voltage or current, 12 to 14 bits according to type of channel and
range BMXAMM0600
Analog I/O modules are equipped with a connector for a 20 or 28-way removable
terminal block, except for BMXART0414/0814 analog input modules for
thermocouples/temperature probes that are equipped with one or two 40-way
connector(s).
Analog modules occupy a single slot in BMXXBPppp racks. These modules can be
installed in any slot in the rack, except the rst two (PS and 00) that are reserved for
the power supply module in the BMXCPSpp0 rack and the BMXP34pp0 processor
module respectively.
The power supply for the analog functions is supplied by the backplane bus (3.3 V
and 24 V). Analog I/O modules are hot-swappable (see page 2/10).
1
2
3
4
5
6
7
8
9
10
2/19
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Description Modicon M340
automation platform
Analog I/O modules
Description
BMXAMp/ART analog I/O modules are standard format (1 slot). They have a case
that helps to ensure IP 20 protection of the electronics, and are locked into position
by a captive screw
I/O modules connected via 20 or 28-way removable terminal block
BMXAMp analog I/O modules feature the following:
Rigid body providing support and protection for the electronic card1
Module reference marking (a label is also visible on the right-hand side of the 2
module)
Module and channel status display block3
Connector taking the 20 or 28-way removable screw or spring-type terminal 4
block for directly connecting the sensors or preactuators to the module.
To be ordered separately:
A 1 BMXFTB20p0 or BMXFTB2820 20 or 28-way removable terminal block
(referencing label supplied with each I/O module) or pre-wired cables with:
20-way terminal block at one end and ying leads at the other -
(BMXFTWp01S)
28-way terminal block at one end and ying leads at the other -
(BMXFTWp08S)
20 or 28-way terminal block and a 25-way SUB-D connector ( - BMXFCApp0
or BMXFTApp0), for connection to Modicon Telefast ABE7 sub-bases
(see page 2/23).
I/O modules connected via 40-way connector
BMXARTanalog input modules feature the following:
Rigid body providing support and protection for the electronic card1
Module reference marking (a label is also visible on the right-hand side of the 2
module)
Module and channel status display block3
One (or two) 40-way connector(s) for connecting the sensors4
To be ordered separately:
Pre-wired cables with:1
40-way connector at one end and ying leads at the other - BMXFCWp01S
40-way connector and a 25-way SUB-D connector ( - BMXFCApp2) for direct
connection to the Modicon Telefast ABE7 sub-bases (see page 2/23)
To be ordered separately:
Shielding connection kit to help protect against electrostatic discharge, consisting b
of a metal bar and two sub-bases for mounting on the rack supporting the analog
modules
Set of bSTBXSP3020 clamping rings for the shielding braids of analog signal
cables
1
3
4
2
5
Module for connection via 20 or 28-way
removable terminal block
1
3
4
2
5
Module for connection for 40-way connector
1
2
3
4
5
6
7
8
9
10
2/20
Connecting modules with removable terminal blocks
BMXAMI0410, BMXAMO and BMXAMM modules with 20-way terminal block
The 20-way removable terminal blocks (BMXFTB20p0 ) are the same as those used
for discrete I/O modules (screw clamp, cage clamp or spring-type) (see page 2/9).
One version of the removable terminal block is equipped with a 3 or 5 m cordset with
color-coded ying leads (BMXFTWp01S). These pre-assembled cordsets with
reinforced shielding have color-coded ying leads at the other end
1
.
BMXAMI0800/0810 modules with 28-way terminal block
The 28-way removable terminal blocks (BMXFTB2820) are spring-type.
One version of the removable terminal block is equipped with a 3 or 5 m cordset with
color-coded ying leads (BMXFTWp08S). These pre-assembled cordsets with
reinforced shielding have color-coded ying leads at the other end
1
.
Connecting modules with 40-way connectors
BMXART0p14 modules with 40-way connectors
Two types of cordset are available:
Pre-assembled cordsets with reinforced shielding ( bBMXFCWp01S) have
color-coded ying leads at the other end
2
. Available in 3 or 5 m lengths, they enable
easy direct wire-to-wire connection of the analog sensors via terminal blocks.
Pre-assembled cordsets with reinforced shielding ( bBMXFCAp02) have a 25-way
SUB-D connector at the other end
3
. Available in 1.5, 3 or 5 m lengths, they enable
direct connection to the Modicon Telefast ABE7CPA412 sub-base (see below).
Use with Modicon Telefast ABE7 sub-bases
Using the Modicon Telefast ABE7 pre-wired system makes it easier to install the
modules since the inputs (or outputs) can be accessed via screw terminals. 7 special
sub-bases are available:
Modicon Telefast ABE7CPA410 sub-base
The Modicon Telefast ABE7CPA410 sub-base is mainly used in conjunction with the
BMXAMI0410 voltage/current analog 4-input module. This sub-base allows you to:
Directly connect 4 sensors b
Remotely locate the input terminals in voltage mode b
Power the 4 to 20 mA conditioning units one channel at a time with a 24 V voltage, b
limited to 25 mA, while maintaining isolation between channels
Help protect the current impedance matching resistors integrated in the sub-base b
against overvoltages
Connection is via the BMXFCApp0 cordset (1.5, 3 or 5 m long).
Modicon Telefast ABE7CPA412 sub-base
The Modicon Telefast ABE7CPA412 sub-base is specially designed as a wiring
interface for the BMXART0414 and BMXART0814 thermocouple modules. This
sub-base allows you to:
Connect 4 thermocouple probes b
Provide external cold junction compensation with a temperature probe integrated b
in the sub-base
Help ensure continuity of the shielding b
The BMXART0814 module requires two Modicon Telefast ABE7CPA412
sub-bases. The connection with each sub-base is made via a BMXFCApp2 cordset
(1.5, 3 or 5 m long).
Modicon Telefast ABE7CPA21 sub-base
The Modicon Telefast ABE7CPA21 sub-base is compatible with the BMXAMO0210
output module. This sub-base allows you to:
Directly connect 2 current/voltage outputs b
Help ensure continuity of the shielding b
Connection is via the BMXFCApp0
3
cordset (1.5, 3 or 5 m long).
1
3
2
BMXFCWp01S cordset
(with 40-way connector at one end and ying leads at the
other)
BMXFTWp01S cordset
(with 20-way removable terminal block at one end and ying
leads at the other)
BMXART0414
4-channel module
ABE7CPA412 sub-base
BMXFCApp2 cordset
Connections,
combinations
Modicon M340
automation platform
Analog I/O modules
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
1
2
3
4
5
6
7
8
9
10
2/21
Use with Modicon Telefast ABE7 sub-bases (continued)
Modicon Telefast ABE7CPA02 sub-base
The Modicon Telefast ABE7CPA02 sub-base can be used in combination with:
The bBMXAMI0800/0810 analog current input modules with 8 inputs
The bBMXAMO0802 analog current output modules with 8 outputs
This sub-base allows you to:
Connect the 8 analog inputs or outputs point-to-point b
Help ensure continuity of the shielding b
The BMXAMI0800/0810 modules are connected by means of the 1.5 or 3 m long
BMXFTApp0 cables.
The BMXAMO0802 module is connected by means of the 1.5, 3 or 5 m long
BMXFTApp2 cables.
Modicon Telefast ABE7CPA03 sub-base
The Modicon Telefast ABE7CPA03 sub-base can be used in combination with the
BMXAMI0800 voltage/current analog 8-input module. This sub-base allows you to:
Directly connect 8 analog inputs b
Power the current inputs one channel at a time with a voltage of 24 V that is limited b
to 25 mA
Help ensure continuity of the shielding b
The BMXAMI0800 module is connected by means of the 1.5 or 3 m long
BMXFTApp0 cables.
Modicon Telefast ABE7CPA31/31E sub-bases
The Modicon Telefast ABE7CPA31/31E sub-bases can be used in combination with
the BMXAMI0800/0810 voltage/current analog 8-input modules. This sub-base
allows you to:
Directly connect 8 analog inputs b
Power the current inputs one channel at a time with 24 V converters b
Help ensure continuity of the shielding b
The BMXAMI0800/0810 modules are connected by means of the 1.5 or 3 m long
BMXFTApp0 cables.
Complementary specications
BMXART0414/0814 analog input modules
BMXART0414/0814 modules are multi-range input modules with 4 or 8 low-level
isolated inputs (15 bits + sign) respectively. Depending on the choice made during
conguration, the modules offer, for each of the inputs, the following ranges:
Temperature probe: Pt100, JPt100, Pt1000, JPt1000, Cu10, Ni100 or Ni1000 (in b
accordance with DIN43760), with open-circuit detection
Thermocouple: B, E, J, K, L, N, R, S, T or U with broken wire detection b
Resistor: 0 to 400 or 0 to 4000 b, 2, 3 or 4-wire
Voltage: ± 40 mV, ± 80 mV, ± 160 mV, ± 320 mV, ± 640 mV, ± 1.28 V b
BMXAMI0410 analog input modules
The BMXAMI0410 module is a high-level analog input module with 4 isolated inputs
(16 bits). Used with sensors or transmitters, it performs monitoring, measurement
and process control functions for continuous processes.The module offers the
following ranges for each of the inputs depending on the choice made during
conguration:
Voltage ± 10 V, ± 5 V, 0 to 10 V, 0 to 5 V and 1 to 5 V b
Current 0 to 20 mA, 4 to 20 mA and ± 20 mA, depending on the choice made b
during conguration
BMXAMI0800/0810 analog input modules
The BMXAMI0800/0810 analog input modules are modules with 8 high-level
isolated/non-isolated analog inputs (15 bits + sign). The modules offer the following
ranges for each of the inputs depending on the choice made during conguration:
Voltage: ± 10 V, 0 to 10 V, 0 to 5 V, 1 to 5 V, ± 5 V b
Current: 0 to 20 mA and 4 to 20 mA b
Combinations (continued),
specications Modicon M340
automation platform
Analog I/O modules
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
1
2
3
4
5
6
7
8
9
10
2/22
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Complementary specications
BMXAMO0210 analog output module
The BMXAMO0210 module is a module with 2 high-level isolated outputs (0.15 bits + sign).
The BMXAMO0210 module offers the following ranges for each of the inputs depending on the choice made
during conguration:
Voltage: ± 10 V b
Current: 0 to 20 mA and 4 to 20 mA b
BMXAMO0410/0802 analog output modules
The BMXAMO0410/0802 analog output modules are modules with 4 or 8 high-level isolated/non-isolated analog
outputs (16 bits/15 bits + sign).
The BMXAMO0410 module offers the following ranges for each of the outputs depending on the choice made
during conguration:
Voltage: ± 10 V b
Current: 0 to 20 mA and 4 to 20 mA b
The BMXAMO0802 module offers the current ranges 0 to 20 mA and 4 to 20 mA.
BMXAMM0600 analog mixed I/O module
The BMXAMM0600 mixed module is a non-isolated I/O module with 4 inputs (14/12) bits and 2 outputs (12 bits).
The module offers the following ranges for each of the inputs or outputs depending on the choice made during
conguration:
Voltage: ± 10 V, 0 to 10 V, 0 to 5 V and 1 to 5 V b
Current: 0 to 20 mA and 4 to 20 mA b
References
Analog input modules (1)
Type of input Input signal range Resolution Connection No. of
channels
Reference Weight
kg
Isolated high-level
inputs
± 10 V, 0 to 10 V,
0 to 5 V, 1 to 5 V, ± 5
V, 0 to 20 mA,
4 to 20 mA, ± 20 mA
16 bits Removable terminal block,
20-way
cage clamp, screw clamp
or spring-type
4 channels
BMXAMI0410
0.143
High-level inputs
non-isolated
± 10 V, 0 to 10 V, 0 to
5 V, 1 to 5 V,
± 5 V, 0 to 20 mA
15 bits
+ sign
Removable terminal block,
28-way, spring-type
8 channels
BMXAMI0800
0.175
Isolated high-level
inputs
± 10 V, 0 to 10 V, 0 to
5 V, 1 to 5 V, ± 5 V, 0
to 20 mA,
15 bits +
sign
Removable terminal block,
28 way, spring-type
8 channels
BMXAMI0810
0.175
Isolated low-level
inputs
Temperature probe,
thermocouple,
± 40 mV, ± 80 mV,
± 160 mV, ± 320 mV,
± 640 mV, ± 1.28 V
15 bits +
sign
40-way connector 4 channels
BMXART0414
0.135
8 channels
BMXART0814
0.165
Analog output modules (1)
Type of outputs Output signal
range
Resolution Connection No. of
channels
Reference Weight
kg
Isolated high-level
outputs
± 10 V,
0 to 20 mA, 4 to 20
mA
16 bits Removable terminal block,
20-way, cage clamp,
screw clamp or spring-type
2 channels
BMXAMO0210
0.144
High-level outputs
isolated
± 10 V,
0 to 20 mA,
4 to 20 mA, ± 20 mA
15 bits
+ sign
Removable terminal block,
20-way, cage clamp,
screw clamp or spring-type
4 channels
BMXAMO0410
0.175
High-level outputs
non-isolated
0 to 20 mA,
4 to 20 mA
15 bits
+ sign
Removable terminal block,
20-way, cage clamp,
screw clamp or spring-type
8 channels
BMXAMO0802
0.175
Analog mixed I/O module (1)
Type of I/O Signal range Resolution Connection No. of
channels
Reference Weight
kg
Mixed I/O, non-isolated ± 10 V, 0 to 10 V,
0 to 5 V, 1 to 5 V,
0 to 20 mA, 4 to 20
mA
14 bits or 12
bits
depending
on the range
Removable terminal block,
20-way, cage clamp,
screw clamp or spring-type
Inputs:
4 channels
Outputs:
2 channels
BMXAMM0600
0.155
(1) Typical consumption: See the power consumption table on page 7/16.
Specications (continued),
references
Modicon M340
automation platform
Analog I/O modules
Input modules, output modules and mixed module
BMXAMp0pp0
BMXART0414
1
2
3
4
5
6
7
8
9
10
2/23
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
References (continued)
Connection accessories for analog modules (1)
Description For use with
modules
Type, composition Length Reference Weight
kg
20-way removable
terminal blocks
BMXAMI0410
BMXAMO0210
MXAMO0410
MXAMO0802
BMXAMM0600
Cage clamp
BMXFTB2000
0.093
Screw clamp
BMXFTB2010
0.075
Spring –
BMXFTB2020
0.060
28-way removable
terminal block
BMXAMI0800
BMXAMI0810
Spring –
BMXFTB2820
0.080
Pre-assembled
cordsets
BMXAMI0410
BMXAMO0210
MXAMO0410
MXAMO0802
BMXAMM0600
One 20-way terminal block
(BMXFTB2020) and one end
with color-coded ying leads
3 m
BMXFTW301S
0.470
5 m
BMXFTW501S
0.700
BMXAMI0800
BMXAMI0810
1 removable terminal block,
28-way, BMXFTB2820, and
one end with color-coded
ying leads
3 m
BMXFTW308S
0.435
5 m
BMXFTW508S
0.750
BMXART0414
BMXART0814
One 40-way connector and one
end with color-coded ying leads
3 m
BMXFCW301S
0.480
5 m
BMXFCW501S
0.710
Modicon Telefast ABE7 pre-wired system
Description For use with
modules
Type, composition Length or
connection
technology
Reference Weight
kg
Modicon Telefast
ABE7 sub-bases
BMXAMI0410 Distribution of isolated power
supplies
Delivers 4 isolated power
supplies for 4 to 20 mA
inputs.
Direct connection of 4 inputs
Screws
ABE7CPA410
0.180
BMXART0414
BMXART0814 (2)
Connection and provision of
cold-junction compensation for
thermocouples
Direct connection of 4 inputs
Screws
ABE7CPA412
0.180
BMXAMO0210
BMXAMO0410
Direct connection of 2/4 outputs Screws
ABE7CPA21
0.210
BMXAMI0800
BMXAMI0810
BMXAMO0802
Point-to-point connection of 8 I/O Screws
ABE7CPA02
0.317
BMXAMI0800 Direct connection of 8 inputs
Delivers 8x 24 V c power
supplies limited to 25 mA to the 8
current inputs
Screws
ABE7CPA03
0.307
BMXAMI0800
BMXAMI0810
Direct connection of 8 inputs
Delivers 8x 24 V c power
supplies isolated and limited to
25 mA to the 8 current inputs
Screws
ABE7CPA31
0.498
Spring
ABE7CPA31E
0.508
Pre-assembled
cordsets for
Modicon Telefast
ABE7 sub-bases
BMXAMI0410
BMXAMO0210
BMXAMO0410
One 20-way removable terminal
block and one 25-way SUB-D
connector for ABE7CPA410/
CPA21 sub-base
1.5 m
BMXFCA150
0.320
3 m
BMXFCA300
0.500
5 m
BMXFCA500
0.730
BMXART0414
BMXART0814 (2)
One 40-way connector and one
25-way SUB-D connector for
ABE7CPA412 sub-base
1.5 m
BMXFCA152
0.330
3 m
BMXFCA302
0.510
5 m
BMXFCA502
0.740
BMXAMI0800
BMXAMI0810
One 28-way removable terminal
block and one 25-way SUB-D
connector for sub-bases
ABE7CPA02/03/31/31E
1.5 m
BMXFTA150
0.374
3 m
BMXFTA300
0.500
BMXAMO0802 One 20-way removable terminal
block and one 25-way SUB-D
connector for ABE7CPA02
sub-bases
1.5 m
BMXFTA152
0.374
3 m
BMXFTA302
0.500
(1) The shielding on the cordsets carrying the analog should always be connected to the BMXXSPpp00 shielding
connection kit mounted under the rack holding the analog modules (see page 1/11).
(2) The BMXART0814 8-channel module requires two ABE7CPA412 sub-bases and two BMXFCApp2 cordsets.
References (continued) Modicon M340
automation platform
Analog I/O modules
Accessories
BMXFTB20p0
BMXFTWp01S
BMXFCApp0
BMXFCApp2
ABE7CPA41p/21
1
2
3
4
5
6
7
8
9
10
2/24
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Programmable process control
Unity Pro software
Process control in machines
Versatile, functional Unity Pro software is a key ingredient in providing
programmable process control. This software contains CONT_CTL, a library of 36
function blocks used to create control loops for machine control.
Requirements for closed loop control functions in machines are readily met by the
Modicon M340 PAC thanks to the wealth of functions in the library and the exibility
with which function blocks can be linked together through programming. This solution
helps to eliminate the need for external controllers and simplies the overall control
architecture of the machine, as well as its design, roll-out and operation.
The function blocks, EF or EFB, can be used in the following Unity Pro languages:
LD, ST, IL and FBD. FBD is particularly suitable for accessing control processing
operations in Unity Pro through its assistant for entering and viewing parameters and
function block variables.
CONT_CTL library functions
The library consists of ve function families:
Input data conditioning
b
Controllers
b
Mathematical functions
b
Measurement processing
b
Output value processing
b
Input data conditioning
DTIME Pure delay time
INTEGRATOR Integrator with limiting
LAG_FILTER First order time lag
LDLG Lead/lag function with smoothing
LEAD Lead function with smoothing
MFLOW Mass ow calculation based on the measurement of differential
pressure or ow speed with pressure and temperature
compensation
QDTIME Dead time term
SCALING Scaling
TOTALIZER Integrator (typically of ow) until a limit (typically a volume) is
reached, with automatic reset
VEL_LIM Velocity limiter, with manipulated variable limiting
Controllers
PI_B Basic PI controller: PI algorithm with a mixed structure
(series/parallel)
PIDFF Complete PID controller: PID algorithm with a parallel or mixed
structure (series/parallel)
AUTOTUNE Automatic tuner setting for the PIDFF (complete PID) controller or
the PI_B (basic PI) controller
Identication using Ziegler Nichols type method
v
Modelling based on rst order process
v
Building of control parameters with criterion for prioritizing
v
either the reaction time to disturbance (dynamic) or the stability of
the process
IMC Model-based controller The model is a rst order model with delay.
This controller is useful:
When there are serious delays compared with the main time
v
constant of the process; this scenario cannot be satisfactorily
resolved by standard PID process control
For regulating a non-linear process IMC can handle any stable
v
and aperiodic process of any order
SAMPLETM Control of controller startup and sampling
STEP2 Simple two-position controller
STEP3 Three-position controller for temperature regulation
Mathematical functions
COMP_DB Comparison of two values, with dead zone and hysteresis
K_SQRT Square root, with weighting and threshold, useful for linearization
of ow measurements
MULDIV_W Weighted multiplication/division of 3 numerical values
SUM_W Weighted summation of 3 numerical values
AUTOTUNE
PV
SP
RCPY
START
PREV
PA RA
TR_I
TR_S
PV_O
SP_O
PA RA_C
TRI
TRS
INFO
STATUS
TT18_PV
TT18_SP
TC18_OUT
TC18_START
TC18_PREV
TC_PARA
TC18_PARA
TC18_OUT
1
TC2_OUT
TC2_OUT
TC18_OUT
PV
SP
PA RA
TR_I
TR_S
PIDFF
FF
RCPY
MAN_AUTO
OUT OUT
OUTD
MA_O
INFO
STATUT
TC2_OUT
MS
TC18_OUT
IN
PA RA
TR_I
TR_S
FORC
MA_FORC
MAN_AUTO
OUT OUT
OUTD
MA_O
STATUT
Example: PID controller with MS manual control
Introduction,
functions
CONT_CTL, programmable process control integrated in
Unity Pro
1
2
3
4
5
6
7
8
9
10
2/25
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Programmable process control
Unity Pro software
CONT_CTL library functions (continued)
Measurement processing
AVGMV Moving average with mounted number of samples (50 max.)
AVGMV_K Moving average with constant correction factor, 10,000 samples
max.
DEAD_ZONE Dead zone
LOOKUP_TABLE1 Linearization of characteristic curves using rst order interpolation
SAH Detection of a rising edge
HYST_XXX (1) Detection of high threshold with hysteresis
INDLIM_XXX (1) Detection of high and low thresholds with hysteresis
Output value processing
MS Manual control of an output
MS_DB Manual control of an output with dead zone
PWM1 Control via pulse width modulation
SERVO Control for servo motors
SPLRG Control of two Split Range actuators
Setpoint management
RAMP Ramp generator, with separate ascending and descending ramps
RATIO Ratio controller
SP_SEL Selection of setpoint value: local (operator) or remote (processing)
Conguration
Conguring process control function blocks
Based on the sequencing of function blocks, the FBD language integrated in Unity
Pro is a programming language particularly suitable for building control loops.
Designers can use FBD to easily associate blocks from the CONT_CTL library with
their own DFB blocks written in Unity Pro’s ST, IL or LD language, or in C language.
Debugging, operation
Unity Pro provides multiple, standard debugging services (see page 4/4). In
particular, the Modicon M340 processor simulator can be used to check correct
execution of processing ofine.
Compatibility
The CONT_CTL control function block library is available in Unity Pro. It is
compatible with the processors in the Modicon M340 product ranges.
Resources
Supplied technical documentation provide many examples of how to set up
programmable process control function blocks in FBD, LD, IL and ST languages.
The techniques for adjusting process control loops are described in the document
“Process control” available online at www.schneider-electric.com
___________________________________________________________________________
(1) XXX depending on the type of variable: DINT, INT, UINT, UDINT, REAL
Programming in Unity Pro in ofine mode
Programming in online mode
Functions (continued),
setup
1
2
3
4
5
6
7
8
9
10
2/26
Selection guide Modicon M340
automation platform
Distributed I/O
Type of splitter box/module Monobloc IP 67 I/O splitter boxes Monobloc IP 20 distributed I/O Optimum IP 20 distributed I/O Modular IP 20 distributed I/O
Modicon FTB Modicon ETB Modicon FTM Modicon MomentumModicon OTB Modicon STB
Available buses and
networks
CANopen Ethernet Modbus TCP/IP
Ethernet/IP
CANopen
Probus DP
DeviceNet
Ethernet Modbus TCP/IP
Modbus Plus
FIPIO
In t e r Bu s ®
Probus DP
DeviceNet
Ethernet Modbus TCP/IP
CANopen
Modbus (RS 485)
Ethernet Modbus TCP/IP
Ethernet/IP
CANopen
Modbus Plus
FIPIO
In t e r Bu s
Probus DP
DeviceNet
Max. number per connection point 1 monobloc splitter box 1 module with
1 monobloc splitter box
1 sub-base with 1 processor or 1 communication
module
1 interface module + 7 Twido expansion modules 1 “NIM” (Network Interface Module) + 32 I/O
modules
Discrete I/O Modularity Splitter box with 16 I, 8 I + 8 O,
12 I + 4 O, 16 I/O or 8 I + 8 I/O
Splitter box with 16 congurable
I/O, 16 I, 12 I + 4 O, or 8 I + 8 O
8 I, 16 I,
8 congurable I/O,
16 congurable I/O,
Sub-base with 16 I, 32 I, 8 O, 16 O, 32 O, 10 I/8 O, 16
I/8 O, 16 I/12 O or 16 I/16 O
12 I/8 O (interface module)
8 I, 16 I, 32 I, 8 O, 16 O, 32 O, 4 I/4 O and 16 I/8 O
(expansion modules)
Module with 2 I, 4 I, 6 I, 16 I, 2 O, 4 O, 6 O or 16 O
Input voltage 24 V c 24 V c, 120 V a and 230 V a24 V c24 V c, 115 V a and 230 V a
Output voltage 24 V c 24 V c, 120 V a and 230 V a and relay 24 V c and relay 24 V c, 115/230 V a and relay
Analog I/O 4 I/4 O 8 I, 16 I or 4 O (voltage/current) sub-bases
Sub-base with 4 thermocouple or probe inputs
2 I, 4 I, 8 I, 1 O, 2 O, 2 I/1 O and 4 I/2 O
(expansion modules)
voltage/current, thermocouple or
temperature probe
Modules with 2, 4 or 8 inputs and 1 or 2 outputs
(voltage/current)
Module with 2 thermocouple or probe inputs
Application-specic I/O 10 kHz/200 kHz 2-channel counter sub-base Integrated in interface module:
- 2 x 5 kHz/20 kHz channels
- 2 PWM function channels
Counter module with 1 x 40 kHz channel
6 I/3 O 120 V a sub-base with 1 Modbus port Parallel interface modules for TeSys Quickt and
TeSys U motor starters, integrated connection for
third-party CANopen products
I/O connection M12 connectors M8 or M12 connectors,
depending on models
Screw or spring-type removable terminal blocks Removable screw terminal block (interface module)
Removable screw terminal block, non-removable
spring-type terminal block and HE 10 connector
(expansion modules)
Removable screw or spring-type connectors,
Telefast connectors.
Type of housing Plastic and metal Plastic Plastic
Module type FTB1 ETB1Eppp FTM1 170ADpOTB1p0DM9LP STBppp
Page Please consult the catalog pages on our website www.schneider-electric.com Please consult the catalog pages on our website www.schneider-electric.com
See more technical information online at www.schneider-electric.com
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
2/27
Type of splitter box/module Monobloc IP 67 I/O splitter boxes Monobloc IP 20 distributed I/O Optimum IP 20 distributed I/O Modular IP 20 distributed I/O
Modicon FTB Modicon ETB Modicon FTM Modicon MomentumModicon OTB Modicon STB
Available buses and
networks
CANopen Ethernet Modbus TCP/IP
Ethernet/IP
CANopen
Probus DP
DeviceNet
Ethernet Modbus TCP/IP
Modbus Plus
FIPIO
In t e r Bu s ®
Probus DP
DeviceNet
Ethernet Modbus TCP/IP
CANopen
Modbus (RS 485)
Ethernet Modbus TCP/IP
Ethernet/IP
CANopen
Modbus Plus
FIPIO
In t e r Bu s
Probus DP
DeviceNet
Max. number per connection point 1 monobloc splitter box 1 module with
1 monobloc splitter box
1 sub-base with 1 processor or 1 communication
module
1 interface module + 7 Twido expansion modules 1 “NIM” (Network Interface Module) + 32 I/O
modules
Discrete I/O Modularity Splitter box with 16 I, 8 I + 8 O,
12 I + 4 O, 16 I/O or 8 I + 8 I/O
Splitter box with 16 congurable
I/O, 16 I, 12 I + 4 O, or 8 I + 8 O
8 I, 16 I,
8 congurable I/O,
16 congurable I/O,
Sub-base with 16 I, 32 I, 8 O, 16 O, 32 O, 10 I/8 O, 16
I/8 O, 16 I/12 O or 16 I/16 O
12 I/8 O (interface module)
8 I, 16 I, 32 I, 8 O, 16 O, 32 O, 4 I/4 O and 16 I/8 O
(expansion modules)
Module with 2 I, 4 I, 6 I, 16 I, 2 O, 4 O, 6 O or 16 O
Input voltage 24 V c 24 V c, 120 V a and 230 V a24 V c24 V c, 115 V a and 230 V a
Output voltage 24 V c 24 V c, 120 V a and 230 V a and relay 24 V c and relay 24 V c, 115/230 V a and relay
Analog I/O 4 I/4 O 8 I, 16 I or 4 O (voltage/current) sub-bases
Sub-base with 4 thermocouple or probe inputs
2 I, 4 I, 8 I, 1 O, 2 O, 2 I/1 O and 4 I/2 O
(expansion modules)
voltage/current, thermocouple or
temperature probe
Modules with 2, 4 or 8 inputs and 1 or 2 outputs
(voltage/current)
Module with 2 thermocouple or probe inputs
Application-specic I/O 10 kHz/200 kHz 2-channel counter sub-base Integrated in interface module:
- 2 x 5 kHz/20 kHz channels
- 2 PWM function channels
Counter module with 1 x 40 kHz channel
6 I/3 O 120 V a sub-base with 1 Modbus port Parallel interface modules for TeSys Quickt and
TeSys U motor starters, integrated connection for
third-party CANopen products
I/O connection M12 connectors M8 or M12 connectors,
depending on models
Screw or spring-type removable terminal blocks Removable screw terminal block (interface module)
Removable screw terminal block, non-removable
spring-type terminal block and HE 10 connector
(expansion modules)
Removable screw or spring-type connectors,
Telefast connectors.
Type of housing Plastic and metal Plastic Plastic
Module type FTB1 ETB1Eppp FTM1 170ADpOTB1p0DM9LP STBppp
Page Please consult the catalog pages on our website www.schneider-electric.com Please consult the catalog pages on our website www.schneider-electric.com
See more technical information online at www.schneider-electric.com
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
2/28
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Introduction,
description
Modicon M340
automation platform
BMXEHC0200/0800 counter modules
Introduction
BMXEHC0200 and BMXEHC0800 counter modules for the Modicon™ M340™
automation platform are used to count the pulses generated by a sensor or to
process the signals from an incremental encoder.
The two modules differ in their number of counter channels, maximum input
frequencies, functions and auxiliary input and output interfaces:
Counter
Module
No. of
channels
Maximum
frequency
Integrated
functions
No. of
physical
inputs
No. of
physical
outputs
BMXEHC0200 2 60 KHz Upcounting
Downcounting
Period meter
Frequency meter
Frequency generator
Axis control
6 2
BMXEHC0800 8 10 KHz Upcounting
Downcounting
Measurement
2 –
The sensors used on each channel can be:
2-wire 24 V proximity sensors b
3-wire 24 V proximity sensors b
10/30 V output signal incremental encoders with push-pull outputs b
BMXEHC0200/0800 counter modules can be used to meet the demands of
applications such as:
Detcted alarm generation on empty unwinder status using the ratio b
Sorting small parts using the period meter b
Single electronic cam using the dynamic setting thresholds b
Speed control using the period meter b
These standard format modules can be installed in any available slot of a
Modicon M340 PAC. They are hot-swappable.
In a Modicon M340 PAC conguration, the number of BMXEHC0200/0800 counter
modules should be added to the number of application-specic modules
(communication).
The function parameters are set by conguration using the Unity Pro software.
Description
BMXEHC0200/0800 counter modules are standard format. They occupy a single
slot in BMXXBPppp racks. They come in a plastic case that helps to ensure IP 20
protection of the electronics, and are locked into position by a captive screw.
BMXEHC0200 module, 2 channels, 60 KHz
The front panel of the BMXEHC0200 counter module features:
Module and channel status display block1
16-way connector for connecting the sensors of counter 02
16-way connector for connecting the sensors of counter 13
10-way connector for connecting:4
Auxiliary outputs -
Sensor power supplies -
To be ordered separately:
BMXXTSHSC20 b kit containing two 16-pin connectors and one 10-pin connector
BMXXSP b pp00 shielding connection kit if the rack is not already equipped with one
(see page 1/11).
BMXEHC0800 module, 8 channels, 10 KHz
The front panel of the BMXEHC0800 counter module features:
Module and channel status display block1
Connector taking the 2 3 BMXFTB20p0 20-way removable terminal block (same
as that of I/O modules)
To be ordered separately:
20-way removable terminal block b3 (cage clamp, screw clamp or spring-type)
BMXFTB20p0
BMXXSP b pp00 shielding connection kit if the rack is not already equipped with one
(see page 1/11).
BMXEHC0200
2
1
3
4
BMXEHC0800
2
1
3
BMXFTB20p0
1
2
3
4
5
6
7
8
9
10
2/29
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Functions Modicon M340
automation platform
BMXEHC0200/0800 counter modules
Operating modes for module BMXEHC0200
8 congurable modes Frequency meter This mode measures frequency, speed, data rate, or an event stream.
As standard, this mode measures the frequency received on the IN A input.
This frequency is expressed in Hz (number of pulses/second), with a precision of 1 Hz.
The maximum frequency on the IN A input is 60 kHz.
The maximum cyclic ratio at 60 kHz is 60%.
Event counting This mode is used to determine the number of events received.
In this mode, the counter calculates the number of pulses applied to the IN_A input at time
intervals dened by the user.
The module counts the pulses applied to the IN_A input each time the pulse for this input lasts
longer than 5 μs (without anti-bounce lter).
Period measurement This mode is used to:
Determine the duration of an event b
Determine the time between 2 events b
Time and measure the execution time of a process b
It measures the time elapsed during an event or between 2 events (IN_A input) according to a
selectable time base of 1 μs, 100 μs or 1 ms.
The IN_SYNC input can be used to enable or stop a measurement.
The module can carry out a maximum of 1 measurement every 5 ms.
The shortest measurable pulse is 100 μs, even if the unit dened by the user is 1 μs.
The maximum measurable duration is 4,294,967,295 units (unit to be dened).
Ratio counting Ratio counting mode only uses the IN_A and IN_B inputs. There are 2 possible modes:
Ratio 1: Used to divide 2 frequencies. This is for applications such as owmeters b
and mixers.
Ratio 2: Used to subtract 2 frequencies. This is for the same applications, but for those b
requiring more precise regulation (more similar frequencies).
Ratio 1 mode gives the results in thousandths for better accuracy (a display of 2000 corresponds
to a value of 2) and ratio 2 mode gives the results in Hz.
The maximum frequency that the module can measure on the IN_A and IN_B inputs is 60 kHz.
Downcounting This mode is used to list a group of operations. In this mode, activating the synchronization
function starts the counter from a user-dened preset and decreases with each pulse applied to
the IN_A input, until it reaches 0. This downcounting is made possible when the enable function
has been activated. The counting register is thus updated at 1 ms intervals.
One basic use of this mode is to signal, using an output, the end of a group of operations (when
the counter reaches 0).
The shortest pulse applied to the IN_SYNC input is 100 μs.
The maximum frequency applied to the IN_SYNC input is 1 pulse every 5 ms.
The maximum user-dened preset value is 4,294,967,295.
The maximum count value is 4,294,967,295 units.
Loop (modulo) counting This mode is used in packaging and labelling applications where actions are repeated on sets
of moving objects:
In upcounting, the counter increases until it reaches the user-dened “modulo - 1” value. On b
the next pulse, the counter is reset to 0 and upcounting restarts.
In downcounting, the counter decreases until it reaches 0. On the next pulse, the counter is b
reset to the user-dened “modulo - 1” value. Downcounting can then restart.
The maximum frequency applied to the IN_A and IN_B inputs is 60 kHz.
The maximum frequency of the modulo event is 1 event every 5 ms.
The maximum modulo value is 4,294,967,296 (possible by declaring 0 in the
modulo adjust value).
32-bit counter counting This mode is mainly used in axis following.
The maximum frequency applied simultaneously to the IN_A and IN_B inputs is 60 kHz.
The maximum frequency of the referencing event is 1 event every 5 ms.
The counter value is between - 2,147,483,648 and + 2,147,483,647.
Width modulation In this operating mode, the module uses an internal clock generator to supply a periodic signal
on the module's O0 output. Only the O0 output is affected by this mode, as the O1 output is
independent of it.
The maximum output frequency is 4 kHz.
As O0 is a source output, a load resistor is necessary for the O0 output signal to change to 0 at
the correct frequency.
The cyclic ratio adjustment range varies according to the frequency of the O0 output.
1
2
3
4
5
6
7
8
9
10
2/30
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Functions (continued) Modicon M340
automation platform
BMXEHC0200/0800 counter modules
Operating modes for module BMXEHC0800
5 congurable 16-bit
modes
Frequency meter This mode measures frequency, speed, rate, or data stream control.
As standard, this mode measures the frequency received on the IN A input.
This frequency is expressed in Hz (number of pulses per second), with a precision of 1 Hz.
The maximum frequency on the IN A input is 10 kHz.
The maximum cyclic ratio at 10 kHz is 60%.
Event counting This mode is used to determine the number of events received.
In this mode, the counter calculates the number of pulses applied to the IN_A input at time
intervals dened by the user.
As an option, it is possible to use the IN_AUX input during a period of time, provided that the
enable bit has been congured.
The module counts the pulses applied to the IN_A input each time the pulse for this input lasts
longer than 50 μs (without anti-bounce lter).
Pulses with less than 100 ms synchronization are lost.
Downcounting This mode is used to list a group of operations. In this mode, when counting is enabled
(software validation via the valid_sync command), a rising or falling edge on the IN_AUX input
causes a value, dened by the user, to be loaded in the counter. The latter decreases with each
pulse applied to the IN_A input until it reaches the value 0. Downcounting is made possible
when the force_enable command is high (software positioning).
The smallest pulse applied to the IN_AUX input varies according to the selected lter level.
The maximum frequency applied to the IN_AUX input is 1 pulse every 25 ms.
Loop (modulo) counting This mode is used in packaging and labelling applications where actions are repeated on sets
of moving objects.
The counter increases with each pulse applied to the IN_A input until it reaches the user-
dened “modulo - 1” value. On the next pulse in the upcounting direction, the counter is reset to
0 and upcounting restarts.
The maximum frequency applied to the IN_A input is 10 kHz.
The smallest pulse applied to the IN_AUX input varies according to the selected lter level.
The maximum frequency of the modulo event is 1 event every 25 ms.
The maximum modulo value is 65,536 units.
Up/down counter This mode is used for an accumulation, upcounting or downcounting operation on a
single input.
Each pulse applied to the IN_A input produces:
Upcounting of pulses if the IN_AUX input is high b
Downcounting of pulses if the IN_AUX input is low b
The counter values vary between the limits - 65,536 and + 65,535.
The maximum frequency applied to the IN_A input is 10 kHz.
Pulses applied to the IN_A input after a change of direction are only upcounted or downcounted
after a period corresponding to the delay for taking account of the state of the IN_AUX input due
to the programmable lter level on this input.
One 32-bit mode 32-bit counter counting 32-bit counter counting mode is available for channels 0, 2, 4 and 6 (channels 1, 3, 5 and 7 are
now inactive). It behaves in the same way as the up/down counting mode using up to 3 physical
inputs. It enables simultaneous upcounting and downcounting.
The counter values vary between the limits - 2,147,483,648 and + 2,147,483,647 (31 bits +
sign).
The maximum frequency applied to the IN_A and IN_B inputs is 10 kHz.
The smallest pulse applied to the IN_AUX input is dened according to the ltering applied to
this input.
The maximum frequency of loading the preset value is 1 every 25 ms.
1
2
3
4
5
6
7
8
9
10
2/31
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
References Modicon M340
automation platform
BMXEHC0200/0800 counter modules
References
BMXEHC0200/0800 counter modules (1)
Description No. of
channels
Specications
Reference
Weight
kg
Counter modules
for 24 V c
2 and 3-wire sensors and
10/30 V c incremental
encoders with push-pull
outputs
2 60 kHz counting BMXEHC0200 0.112
8 10 kHz counting
BMXEHC0800 0.113
Connection accessories (2)
Description Composition Unit reference Weight
kg
Pack of connectors
for BMXEHC0200 module
Two 16-way connectors and
one 10-way connector
BMXXTSHSC20 0.021
20-way removable
terminal blocks
for BMXEHC0800 module
Cage clamp BMXFTB2000 0.093
Screw clamp BMXFTB2010 0.075
Spring BMXFTB2020 0.060
Shielding connection kit
for BMXEHC0200/0800
modules
Is comprised of a metal bar and two
support bases for mounting on rack
See page1/11
(1) Typical consumption: See the power consumption table on page 7/16.
(2) The shielding on the cordsets carrying the counter signals should be connected to the
BMXXSPpp00 shielding connection kit mounted under the rack that holds the BMXEHC0200
module (see page 1/11).
BMXEHC0200
BMXEHC0800
BMXFTB20p0
1
2
3
4
5
6
7
8
9
10
2/32
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Introduction,
description
Modicon M340
automation platform
BMXMSP0200 motion control module
Introduction
The BMXMSP0200 motion control pulse train output (PTO) module 1 for the
Modicon M340 automation platform is used for controlling third-party variable
speed drives 2 that have an integrated position loop and inputs that are compatible
with open collector outputs.
The BMXMSP0200 control module is also directly compatible with the Lexium 32C
and 32M 3 servo drive products that have an integrated pulse control interface.
The BMXMSP0200 motion control PTO module has two independent PTO channels.
Like any other application-specic module, it is installed in the rack slots (labelled 01
to 11). The number of modules is limited by the maximum number of application-
specic channels permitted according to the CPU type:
Standard bBMXP341000: Maximum of 20 application-specic channels (1)
Performance bBMXP3420p0: Maximum of 36 application-specic channels (1)
Description
The BMXMSP0200 motion control module is standard format (1 slot). Its housing
provides IP 20 protection of the electronics and it is locked in each slot (01 to 11) by a
captive screw.
The BMXMSP0200 motion control module features:
Rigid body providing support and protection for the electronic card4
Module reference marking (a label is also visible on the right-hand side of the 5
module)
Display block indicating:6
Module status, 4 LEDs (RUN, ERR, I/O and DL)
v
Status of the auxiliary inputs, 4 per channel
v
Status of the PTO outputs, 2 per channel
v
Status of the auxiliary outputs, 2 per channel
v
Connector for a 28-way terminal block, for connecting to a removable spring 7
terminal block on sensors and preactuators
To be ordered separately:
28-way removable spring terminal block 8 BMXFTB2820, supplied with a channel
identication label
Shielding connection kit to help protect against electrostatic discharge, consisting b
of a metal bar and two sub-bases for mounting on the rack: BMXXSPpp00 (reference
dependent on the number of slots in the rack) (see page 1/11)
Set of clamping rings bSTBXSP30p0 for the connection cable shielding braids
(reference dependent on the cable Ø) (see page 1/11)
(1) Application-specic channels: BMXEHC0200 (2-channel) and BMXEHC0800 (8-channel)
counter modules, BMXMSP0200 (2-channel) motion control module and BMXNOM0200
(2-channel) and BMXNOR0200H (1-channel) serial communication modules
4
5
6
7
8
BMXMSP0200 BMXFTB2820
Servo motors
1
2
3
1
2
3
4
5
6
7
8
9
10
2/33
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Operation
Block diagram of a BMXMSP0200 module channel
Integrator
Pulses
PTO output CCWp
24 V c output D_Enable
24 V c output C_Clear
C_Position
D_Ready
Origin
Proximity
Speed
Proximity sensor
Position switch
Homing
Position
loop
Velocity
loop
Torque
loop
Wait position
Servo ready
PTO output CWpServo drive
Servo
motor
BMXMSP0200
Inputs/outputs per channel
References
Motion control modules (1)
Description Number of
channels
Description
per channel
Reference Weight
kg
PTO module
(PTO = Pulse
Train Output)
2 2 x 200 kHz max. PTO outputs
2 x 24 V c/50 mA auxiliary outputs
4 x 24 V c auxiliary inputs
BMXMSP0200 0.145
Cabling accessories
Description Description, use Length Reference Weight
kg
28-way
removable
terminal block
Spring BMXFTB2820 0.080
Connection
cable for daisy
chain
or pulse
control (2)
From BMXMSP0200 (screw terminal block)
module to Lexium 32C or 32M (RJ45 connector)
(cable with ying leads at one end and an RJ45
connector at the other)
3 m (3) VW3M8223R30
Shielding
connection kit
for module
BMXMSP0200
Is comprised of a metal bar and two support
bases
for mounting on rack
See page1/11
(1) Typical consumption: See the power consumption table on page 7/16.
(2) The shielding on the cordsets carrying the motion control signals should be connected to the BMXXSPpp00
shielding connection kit mounted under the rack holding the BMXMSP0200 module (see page 1/11).
BMXMSP0200
BMXFTB2820
Operation,
references
Modicon M340
automation platform
BMXMSP0200 motion control module
1
2
3
4
5
6
7
8
9
10
2/34
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Introduction,
functions
Modicon M340
automation platform
MFB motion control
Introduction
MFB (Motion Function Blocks) is a library of function blocks integrated in Unity Pro
software that is used to set up motion control in the architectures of drives and servo
drives on CANopen buses:
Altivar b 312: For asynchronous motors from 0.18 to 15 kW
Altivar b 71: For synchronous or asynchronous motors from 0.37 to 500 kW
Lexium b 32: For servo motors from 0.15 to 7 kW
IclA IFA/IFE/IFS: For integrated motor drives from 0.05 to 0.25 kW b
The MFB library, designed to PLCopen specications, allows both easy and exible
motion programming with Unity Pro, as well as axis diagnosis. In maintenance
operations, drives can be replaced quickly by using drive parameter download blocks.
Conguring drives on the CANopen network is facilitated through Motion Tree
Manager organization in the Unity Pro browser, making it easy for users to access
the application drives.
Applications
The features of the Motion Function Blocks library are particularly suitable for
machines with independent axes. In the case of these modular/special machines,
MFB function blocks are the solution for controlling single axes. The following are
typical applications for this type of architecture:
Automatic storage/removal b
Material handling b
Palletizers/depalletizers b
Conveyors b
Packaging, simple label application b
Grouping/ungrouping b
Adjustment axes in exible machines. b
Functions
The table below lists the function blocks of the MFB library and the drives compatible
with them. The premount indicates the block family:
MC: Function block dened by the Motion Function Blocks PLCOpen standard b
TE: Function block specic to Schneider Electric products b
Lxm: Function block specic to Lexium servo drives b
Type Function Function block Altivar 312 Altivar 71 Lexium 32 IclA IFA/
IFE/IFS
Management
and motion
Read an internal parameter MC_ReadParameter
Write an internal parameter MC_WriteParameter
Read the current position MC_ReadActualPosition
Read the instantaneous speed MC_ReadActualVelocity
Acknowledge detected error messages MC_Reset
Stop active movement MC_Stop
Axis coming to standstill MC_Power
Movement to absolute position MC_MoveAbsolute
Relative movement MC_MoveRelative
Additional movement MC_MoveAdditive
Homing MC_Home
Movement at given speed MC_MoveVelocity
Read diagnostic data MC_ReadAxisError
Read servo drive status MC_ReadStatus
Torque control MC_TorqueControl
Read actual torque value MC_ReadActualTorque
Manual control MC_Jog
Save and
restore
parameters
(FDR)
Read parameters and store in PAC memory TE_UploadDriveParam
Write parameters from the PAC memory TE_DownloadDriveParam
Advanced
Lexium
functions
Read a motion task Lxm_UploadMTask
Write a motion task Lxm_DownloadMTask
Start a motion task Lxm_StartMTask (1)
Set the reduction ratio, signed Lxm_GearPosS (1)
System Communication with the servo drive TE_CAN_Handler
Compatible (1) The Lxm_StartMTask and Lxm_GearPosS function blocks are only compatible with the M
type Lexium 32 (LXM 32M) servo drives.
MFB: Motion control distributed over CANopen
Altivar 312
Lexium 32
IclA
Altivar 71
CANopen
Modicon M340
Modicon Premium
1
2
3
4
5
6
7
8
9
10
2/35
Processors:
page 1/2 Communication:
page 3/2 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Setup Modicon M340
automation platform
MFB motion control
Motion Tree Manager
Motion Tree Manager is part of Unity Pro’s MFB library and is integrated into its
browser. It provides specic assistance for:
Axis object management b
Axis variable denition b
Drive parameter management b
Motion Tree Manager automatically creates links between the CANopen bus
conguration and the MFB function block data using a limited amount of
conguration data.
General axis parameters
In this tab, the designer is prompted to dene:
The name of the axis that will identify it in the browser for the entire application b
The address of the drive on the CANopen bus b
Axis parameters
The drop-down lists in this tab are used to determine the exact type of drive: Family,
version.
Variable names
This last tab is used to identify data structures:
Axis_Reference: bUsed by the instances of function blocks for the axis in question
CAN_Handler: bUsed to manage communication with the drive via the CANopen
network
Recipe denition
The “recipes” attached to the axis are the data structures containing the adjustment
parameters of a given drive. This data is used when:
Changing the drive with restoration of the context during b“Faulty Device
Replacement” (FDR) maintenance
Changing the manufacturing program of the machine and calling up an b
appropriate set of parameters: servo control gains, limitations, etc. adapted to the
weight and size of the moving parts
Saving parameters in the initial values of the PAC application b
Programming, diagnostics and maintenance
Communication between the PAC and drive is automatically set up by the system as
soon as a TE_CAN_Handler instance is declared in the Unity Pro task with which the
axis is associated. Movements are then programmed by sequencing function blocks
from the library in the user's chosen Unity Pro editor (LD, ST, FBD).
The two function blocks, MC_ReadStatus, and in some cases MC_ReadAxisError,
are useful for determining the overall status of the axis, as well as the code of active
warnings or error messages.
The function blocks TE_UploadDriveParam and TE_DownloadDriveParam allow the
application to save the parameters of a drive (recipe) and to then quickly reload them
into another drive if the rst one becomes inoperative.
Motion Tree Manager integrated in the Unity Pro browser
General parameters: Axis name and address
MFB: Programming a movement in absolute mode
1
2
3
4
5
6
7
8
9
10
2/36
Introduction
Quick Wiring Adapters are a set of connectors for the Modicon M340 automation
platform. These connectors simplify the replacement of a legacy Modicon Compact
PAC with our latest offer, the M340 PAC.
The adapters allow I/O eld wiring connectors to be removed from the Compact PAC
and plugged directly into the M340.
Thirteen new references make the necessary wiring translations between Compact
and M340 I/O modules and fully meet the mechanical environmental specications
of the M340 range.
Quick Wiring Adapters Features
Quick Wiring Adapters have the same look and feel as the standard M340 I/O module
connectors. The new connectors increase the depth and extend below the I/O module.
The quick wiring adapters use the same mounting/retention screws to hold the b
adapter to the M340 module
The adapter receptacles accept the two (2) Compact I/O module eld b
wiring connectors
A clear cover is sized to retain the wiring harness b
The cover also has features to accept and retain the wiring label that was used on b
the Compact I/O module
Introduction,
compatibility
Modicon M340
automation platform
Quick wiring adapters for Modicon M340 PAC
Compact modules/Modicon M340 modules compatibility
Type of
module
Compact Module M340 Module M340 Compatibility Quick Wiring
Adapter
reference
Reference Comment Reference Comment
Digital input AS-BDE O 216 24 VDC 16 Point Input
Module BMXDDI1602 16 point 24 VDC input sink O.K. 990XSM00206
AS-BDEP 208 230 VAC 8 Point Input
Module No exact replacement but Modicon
Telefast separate product line can handle
it.
AS-BDEP 209 120 VAC 8 Point Input
Module BMXDAI1604 16 point 110 VAC input O.K. 990XSM00213
AS-BDEP 210 115 VAC 8 Point Input
Module BMXDAI1604 16 point 110 VAC input O.K. 990XSM00213
AS-BDEP 211 115 VAC 8 Point Input
Module BMXDAI1604 16 point 110 VAC input O.K. None
AS-BDEP 214 12-60 VDC 16 Point Input
Module BMXDDI1603 16 point 48 VDC input No replacement for 12 V, 24 V and 60 V 990XSM00206
AS-BDEP 215 5 VDC TTL 16 Point Input
Module No exact replacement but can be replaced
with HMI functionality. None
AS-BDEP 216 24 VDC 16 Point Input
Module BMXDDI1602 16 point 24 VDC input sink O.K. 990XSM00206
AS-BDEP 217 24 VDC 16 Point Input
Module BMXDAI1602 16 point 24 VDC input sink OK but need negative logic. 990XSM00201
AS-BDEP 218 115 VAC 16 Point Input
Module BMXDAI1604 16 point 110 VAC input O.K. 990XSM00201
AS-BDEP 220 Fast 24 VDC 16 Point Input
Module
Depending upon the response time there
are replacements. None
AS-BDEP 254 12-60 VDC 16 Point Input
Module BMXDDI1603H 16 point 48 VDC input BMXDDI1603 input threshold is 34 V
versus 12 V for AS-BDEP254.
Temperature is 0 to + 60 °C for
BMXDDI1603 where AS-BDEP254 is
rated for - 40 to + 70 °C
990XSM00206
AS-BDEP 254C 12-60 VDC 16 Point Input
Module, ext temp + Coated BMXDDI1603H 16 point 48 VDC input BMXDDI1603 input threshold is 34 V
versus 12 V for AS-BDEP254.
Temperature is 0 to + 60 °C for
BMXDDI1603 where AS-BDEP254 is
rated for - 40 to + 70 °C
990XSM00206
AS-BDEP 256 24 VDC 16 Point Input
Module BMXDDI1602H 16 point 24 VDC input sink BMXDDI1602 is only rated for 0 to + 60 °C
versus - 40 to + 70 °C for AS-BDEP256. 990XSM00206
AS-BDEP 256C 24 VDC 16 Point Input
Module, ext temp + Coated BMXDDI1602H 16 point 24 VDC input sink BMXDDI1602 is only rated for 0 to + 60 °C
versus - 40 to + 70 °C for AS-BDEP256C 990XSM00206
AS-BDEP 257 110 VDC 16 inputs Ext.
Temp BMXDDI1604T 16 point 125 VDC input Nominal input voltage for BMXDDI1604 is
100 to 150 VDC versus 55 to 170 VDC for
AS-BDEP257. Response time for
BMXDDI1604 is 9 ms versus 6 ms for the
AS-BDEP257. Temperature for
BMXDAI1604T is -25 to + 70 °C versus
- 40 to + 70 °C.
990XSM00206
AS-BDEP 257C 110 VDC 16 inputs, ext
temp + Coated BMXDDI1604T 16 point 125 VDC input Nominal input voltage for BMXDDI1604 is
100 to 150 VDC versus 55 to 170 VDC for
AS-BDEP257. Response time for
BMXDDI1604 is 9 ms versus 6 ms for the
AS-BDEP257. Temperature for
BMXDDI1604T is -25 to + 70 °C versus -
40 to + 70 °C. No conformal coat available.
990XSM00206
AS-BDEP 296 60 VDC 16 inputs No replacement
AS-BDEP 297 48 VDC 16 inputs BMXDDI1603 16 point 48 VDC input O.K. 990XSM00206
Green color with no comments reect the functional equivalent of M340 module for Compact module.
Green color with comment reect the functional equivalent with differences noted. Check with your application.
Orange color indicates that inputs are replaced by the M340 module but differences from the Compact module are noted. For example maxi current per point. Check with your application.
Red color indicates that there are no direct replacements but there are workarounds. Please consult Schneider Electric for assistance.
1
2
3
4
5
6
7
8
9
10
2/37
Compatibility (continued) Modicon M340
automation platform
Quick wiring adapters for Modicon M340 PAC
Compact modules/Modicon M340 modules compatibility
Type of
module
Compact Module M340 Module M340 Compatibility Quick Wiring
Adapter
reference
Reference Comment Reference Comment
Digital
output
AS-BDAO 216 24 VDC 16 Point Output
Module BMXDDO1602 16 point Output 24 VDC O.K with slightly slower response.
BMXDDO1602 response time 1.2 ms vs. <
1 ms for AS-BDAO216
990XSM00206
AS-BDAP 204 4 Point Relay (NO) Module BMXDRA0805 8 point relay outputs O.K. 4 relay on Compact 8 on M340. 990XSM00203
AS-BDAP 208 8 Point Relay (NO) Module BMXDRA0805 8 point relay outputs O.K. 990XSM00206
AS-BDAP 258 8 Point Relay (NO) Module BMXDRA0805H 8 point relay outputs O.K. But Extended temperature
differences 990XSM00206
AS-BDAP 258C 24 VDC 8 Point Relay (NO)
Module, ext temp + Coated BMXDRA0805H 8 point relay outputs O.K. Temperature limitation where 0 to +
60 °C versus - 40 to + 70 °C and the
BMXDRA0805H.
990XSM00206
AS-BDAP 209 120 VAC 8 Point 1A Output
Module BMXDAO1605 16 point output 110 VAC to
230 VAC
Less amperage available.
BMXDAO1605 is limited to 600 mA vs. 1A
for AS-BDAP 210
AS-BDAP210 nominal voltage goes down
to 85 V vs. 100 V for BMXDAO1605
990XSM00204
AS-BDAP 210 24-230 VAC 8 Point Output
Module BMXDAO1605 16 point output 110 VAC to
230 VAC
Less amperage available.
BMXDAO1605 is limited to 600 mA vs. 1A
for AS-BDAP210.
AS-BDAP 210 nominal voltage goes down
to 85 V vs. 100 V for BMXDAO1605
990XSM00204
AS-BDAP 212 24 VDC 8 Point Input/4
Point Output 2A BMXDDM16025 8 point 24 VDC input + 8
point relay output
Compact 2 groups of 2 outputs, M340 1
group of 8. Input isolation is different. 990XSM00205
AS-BDAP 252 24 VDC 8 Point Input/4
Point Output 2A BMXDDM16025H 8 point 24 VDC input + 8
point relay output
Compact 2 groups of 2 outputs, M340 1
group of 8. Input isolation is different.
Extended temperature differences
990XSM00205
AS-BDAP 216 24 VDC 16 Point Output
Module BMXBMXDDO1602 16 point 24 VDC output Compact is 2 groups of 8, M340 1 group of
16. So difference inputs isolation 990XSM00206
AS-BDAP 256 24 VDC 16 Point Output
Module BMXBMXDDO1602H 16 point 24 VDC output Compact is 2 groups of 8, M340 1 group of
16. So difference inputs isolation
Extended temperature differences
990XSM00206
AS-BDAP 217 5-24 VDC 16 Point Output
Module BMXBMXDDO1612 16 point 24 VDC output
sink
Response time is slightly slower.
BMXDDO1612 at 1.2 ms versus <1 ms for
AS-BDAP217. Also Compact is 2 groups
of 8, M340 1 group of 16.
990XSM00206
AS-BDAP 218 24-240 VAC 16 Point
Output Module BMXDAO1605 16 point output 110 VAC to
230 VAC
Less amperage available.
BMXDAO1605 is limited to 600 mA vs. 1 A
for AS-BDAP210
AS-BDAP 210 nominal voltage goes down
to 24 V vs. 100 V for BMXDAO1605.
If 24 V is needed select a different module.
990XSM00202
AS-BDAP 211 120 VAC Mixed Press and
Stamp Module, Inputs
controlling Outputs
None None
Digital
input/output
AS-BDAP 220 24 VDC 8 Point Input/
Output Module 2A BMXDDM16022 8 point 24 VDC input + 8
point 24 VDC output
BMXDDM16022 is limited to 0.625 A per
channel versus AS-BDAP220 2 A. Also
response time is 1.2 ms versus < 1 ms for
AS-BDAP220
990XSM00207
AS-BDAP 250 24 VDC 8 Point Input/
Output Module BMXDDM16022H 8 point 24 VDC input + 8
point 24 VDC output
BMXDDM16022 is limited to 0.625 A per
channel versus AS-BDAP250 2 A and is
not conformally coated.
Also response time is 1.2 ms versus < 1
ms for AS-BDAP220.
BMXDDM16022 is 0 to + 60 °C versus - 40
to + 70 °C for AS-BDAP250C.
990XSM00207
AS-BDAP 250C 24 VDC 8 Point Input/
Output Module, ext temp +
Coated
BMXDDM16022H 8 point 24 VDC input + 8
point 24 VDC output
BMXDDM16022 is limited to per channel
versus AS-BDAP250 2 A. Also response
time is 1.2 ms versus <1 ms for
AS-BDAP220. DDM16022 is 0 to + 60 °C
versus - 40 to + 70 °C for AS-BDAP250C.
990XSM00207
AS-BDAP 212 24 VDC 8 inputs 4 outputs BMXDDM16025 8 point 24 VDC input + 8
point relay output
Compact 2 groups of 2 outputs, M340 1
group of 8. So difference inputs isolation. 990XSM00205
AS-BDAP 252 24 VDC 8 inputs 4 outputs BMXDDM16025H 8 point 24 VDC input + 8
point relay output
BMXDDM16025 is 0 to + 60 °C versus - 40
to + 70 °C. Compact 2 groups of 2
outputs, M340 1 group of 8. So difference
inputs isolation.
990XSM00205
AS-BDAP 252C 24 VDC 8 inputs 4 outputs,
ext temp + Coated BMXDDM16025H 8 point 24 VDC input + 8
point relay output
BMXDDM16025 is 0 to + 60 °C versus - 40
to + 70 °C. Compact 2 groups of 2
outputs, M340 1 group of 8. So difference
inputs isolation.
990XSM00205
AS-BDAP 253 110 VDC 8 inputs 4 outputs BMXDDM16025H 8 point 24 VDC input + 8
point relay output
1) Compact inputs 110 VDC, M340 24
VDC
2) Compact 2 groups of 2 outputs, M340 1
group of 8.
a) Output isolation is different
b) 4 unused references,
None
AS-BDAP 253C 110 VDC 8 inputs 4
outputs, ext temp + Coated BMXDDM16025H 8 point 24 VDC input + 8
point relay output
1) Compact inputs 110 VDC, M340 24
VDC
2) Compact 2 groups of 2 outputs, M340 1
group of 8.
a) Output isolation is different
b) 4 unused references
None
AS-BDAP 292 60 VDC 8 Inputs 4 outputs No exact replacement but contact
Schneider Electric Technical support for
workarounds.
None
Green color with no comments reect the functional equivalent of M340 module for Compact module.
Green color with comment reect the functional equivalent with differences noted. Check with your application.
Orange color indicates that inputs are replaced by the M340 module but differences from the Compact module are noted. For example maxi current per point. Check with your application.
Red color indicates that there are no direct replacements but there are workarounds. Please consult Schneider Electric for assistance.
1
2
3
4
5
6
7
8
9
10
2/38
Compact modules/Modicon M340 modules compatibility
Type of
module
Compact Module M340 Module M340 Compatibility Quick Wiring
Adapter
reference
Reference Comment Reference Comment
Analog
input
AS-BADU 204 4 Channel, ± 0,5 V,
Register, PT100, 11 Bit BMXART0414 Analog 4 channel TC/RTD
Isolated inputs
O.K., but ± 0.5V missing, also M340 has
Channel to Channel and Channel to Bus
Isolation
None
AS-BADU 205 4 Channel Register Input BMXAMI0410 Analog 4 channel Current/
Voltage Input Isolated
O.K. Scaling differences 990XSM00208
AS-BADU 205 4 Channel Register Input BMXAMM0600 Analog 4 channel Current/
voltage input non-isolated
and 2 channel Current/
voltage output non-isolated
O.K. Scaling differences 990XSM00209
AS-BADU 206 4 Channel Register Input
isolated BMXAMI0410 Analog 4 channel Current/
Voltage Input Isolated
O.K, however M340 does not have ± 1V
range. 990XSM00210
AS-BADU 206 4 Channel Register Input
isolated BMXAMM0600 Analog 4 channel Current/
voltage input non-isolated
and 2 channel Current/
voltage output non-isolated
O.K, however M340 does not have ± 1V
range.
No isolation
990XSM00211
AS-BADU 210 4 Channel Voltage/Current
Input isolated BMXAMI0410 Analog 4 channel Current/
Voltage Input Isolated
O.K. Scaling differences
M340 does not match the voltage ranges. 990XSM00210
AS-BADU 210 4 Channel Voltage/Current
Input isolated BMXAMM0600 Analog 4 channel Current/
voltage input non-isolated
and 2 channel Current/
voltage output non-isolated
O.K. Scaling differences
M340 does not match the voltage ranges.
No isolation
990XSM00211
AS-BADU 211 8 Channel Analog Input
Module Thermo BMXART0814 Analog 8 channel TC/RTD
Isolated inputs
O.K. M340 missing 2, 5, or 10 V input
capability or 4-20 mA , ± 20 mA and
missing external 24 V
None
AS-BADU 212 8 Channel Analog Input
Module Thermo BMXART0814 Analog 8 channel TC/RTD
Isolated inputs
O.K. M340 missing 2, 5, or 10 V input
capability or 4-20 mA , ± 20 mA and
missing external 24 V
None
AS-BADU 214 4/8 Channel Multi Range
Analog/Digital Input BMXART0414 Analog 4 channel TC/RTD
Isolated inputs
M340 missing Voltage range 0 - 10 V, 1 to
5, 2 to 10. and no loop capability. None
AS-BADU 216 4/8 Channel Thermocouple
isolated BMXART0814 Analog 8 channel TC/RTD
Isolated inputs
OK None
AS-BADU 254 4 Channel Register Input BMXAMI0410H Analog 4 channel Current/
Voltage Input Isolated
Ok, and M340 has CH/CH isolation and
CH/Bus where Compact has none.
Extended temperature differences
None
AS-BADU 254 4 Channel Register Input BMXAMM0600H Analog 4 channel Current/
Voltage input and 2
channel Current Voltage
Output
Ok. M340 has 4 inputs and 2 outputs.
Extended temperature differences None
AS-BADU 254C 4 Channel Register Input,
ext temp + Coated BMXAMI0410H Analog 4 channel Current/
Voltage Input Isolated
Ok, and M340 has CH/CH isolation and
CH/Bus where Compact has none.
Extended temperature differences
None
AS-BADU 254C 4 Channel Register Input,
ext temp + Coated BMXAMM0600H Analog 4 channel Current/
Voltage input and 2
channel Current Voltage
Output
OK, M340 has 4 inputs and 2 outputs.
With no isolation
Extended temperature differences
None
AS-BADU 256 4 Channel Register Input
Isolated BMXAMI0410H Analog 4 channel Current/
Voltage Input Isolated
OK but Extended temperature differences None
AS-BADU 256 4 Channel Register Input
Isolated BMXAMM0600H Analog 4 channel Current/
Voltage input and 2
channel Current Voltage
Output
OK, M340 has 4 inputs and 2 outputs.
With no isolation
Extended temperature differences
None
AS-BADU 256C 4 Channel Register Input
Isolated, ext temp +
Coated
BMXAMI0410H Analog 4 channel Current/
Voltage Input Isolated
OK but Extended temperature differences 990XSM00210
AS-BADU 256C 4 Channel Register Input
Isolated, ext temp +
Coated
BMXAMM0600H Analog 4 channel Current/
Voltage input and 2
channel Current Voltage
Output
OK M340 has 4 inputs and 2 outputs with
no isolation 990XSM00211
AS-BADU 257 8 Channel Thermocouple BMXART0814H Analog 8 channel TC/RTD
Isolated inputs
Ok but extended temperature differences None
AS-BADU 257C 8 Channel Thermocouple,
ext temp + Coated BMXART0814H Analog 8 channel TC/RTD
Isolated inputs
Ok but extended temperature differences None
Analog
output
AS-BDAU 202 2 Point AN Outputs, ± 10 V,
± 20 mA BMXAMO0210 Analog 2 channel Current/
Voltage Output Isolated
M340 has no negative 20 mA capability. 990XSM00212
AS-BDAU 204 4 Channel Analog
Output,Opto-Isol. BMXAMO0210 Analog 2 channel Current/
Voltage Output Isolated
M340 does not support 0 to 1 V, 0 to 5 V, ±
1V. +-5 V ranges None
AS-BDAU 208 8 Channel Register Output No 8 point analog output Need to use two
modules. None
AS-BDAU 252 2 Point AN Outputs, ± 10 V,
± 20 mA Extended
Temperature
BMXAMO0210H Analog 2 channel Current/
Voltage Output Isolated
M340 has no negative 20 mA capability.
Extended temperature differences 990XSM00212
AS-BDAU 252C 2 Point AN Outputs, ± 10 V,
± 20 mA , ext temp +
Coated
BMXAMO0210H Analog 2 channel Current/
Voltage Output Isolated
M340 has no negative 20 mA capability.
Extended temperature differences 990XSM00212
Comm. AS-BBKF 202 INTERBUS S Slave No replacement None
AS-BBKF201-16 16 Word INTERBUS S
Master
––No replacement None
AS-BBKF201-64 64 Word INTERBUS S
Master
––No replacement None
CM900 Auto Interface No replacement None
Compatibility (continued) Modicon M340
automation platform
Quick wiring adapters for Modicon M340 PAC
Green color with no comments reect the functional equivalent of M340 module for Compact module.
Green color with comment reect the functional equivalent with differences noted. Check with your application.
Orange color indicates that inputs are replaced by the M340 module but differences from the Compact module are noted. For example maxi current per point. Check with your application.
Red color indicates that there are no direct replacements but there are workarounds. Please consult Schneider Electric for assistance.
1
2
3
4
5
6
7
8
9
10
2/39
Compact modules/Modicon M340 modules compatibility
Type of
module
Compact Module M340 Module M340 Compatibility Quick Wiring
Adapter
reference
Reference Comment Reference Comment
Ser. Comm. AS-BKOS260-24 24 Word Universal Comm ––Contact Schneider Electric Technical
support for appropriate alternatives.
READ_VAR functionality might replace
this.
None
AS-BKOS260-64 64 Word Universal Comm ––Contact Schneider Electric Technical
support for appropriate alternatives.
READ_VAR functionality might replace
this.
None
M7251 Programmable limit switch No replacement, No Motion None
M7350 Resolver Decoder No replacement, No Motion None
Motion AS-BMOT 201 Axis Motion Control
Module Encoder
––Contact Schneider Electric Technical
support for appropriate alternatives. None
AS-BMOT 202 Axis Motion Control
Module Resolver &
Encoder
––Contact Schneider Electric Technical
support for appropriate alternatives. None
Counter AS-BFRQ 204 4 point Frequency Module BMXEHC0200 High Speed Counter 2
channel
No 5 V input. Also contact Schneider
Electric Technical support for correct
replacement
None
AS-BFRQ 254C 4 point Frequency Module,
ext temp + Coated BMXEHC0200H High Speed Counter 2
channel
No 5 V input. Also contact Schneider
Electric Technical support for correct
replacement
None
AS-BVIC200 VRC200 4 High Speed Pulse or 4
VRC Inputs
––Contact Schneider Electric Technical
support for appropriate alternatives. None
AS-BVIC205 CTR205 4 High Speed Pulse or 4
5V TTL Inputs
––Contact Schneider Electric Technical
support for appropriate alternatives. None
AS-BVIC212 CTR212 4 High Speed Pulse or 12
VDC Inputs
––Contact Schneider Electric Technical
support for appropriate alternatives. None
AS-BVIC224 CTR224 4 High Speed Pulse or 24
VDC Inputs BMXEHC0800 High Speed Counter 8
channel
Contact Schneider Electric Technical
support for appropriate alternatives. None
AS-BZAE 201 High speed Counter/
Positioner (2 Relay) BMXEHC0200 High Speed Counter 2
channel
Counter 12 V O.K., no relay outputs, no
5V, no positioning None
AS-BZAE 204 4 Channel High speed
Counter/Positioner BMXEHC0800 High Speed Counter 8
channel
O.K. No outputs None
CPU AS-B984-A145 up to
E984-285
BMXP342020 +
BMXCSP3020
Only 1 Modbus port on CPU. 2 port NOM
serial module available. None
AS-P120 000 105 to 240 VAC inputs, 24
VDC 1.0A outputs BMXCSP2000 /
BMXCSP3500
None
Notes:
Extended temperature modules for M340 have an “H” sufx at the end of the part number. v
The Modicon Compact PAC line had an extended temperature range of - 40 °C to + 70 °C. The M340 line has an extended temperature of - 25 °C to + 70 °C. v
Derating of temperature might apply inputs certain applications.
As with any PAC migration even an exact module to module replacement might not yield the same results (due to scan time, etc). v
Compatibility (continued) Modicon M340
automation platform
Quick wiring adapters for Modicon M340 PAC
Green color with no comments reect the functional equivalent of M340 module for Compact module.
Green color with comment reect the functional equivalent with differences noted. Check with your application.
Orange color indicates that inputs are replaced by the M340 module but differences from the Compact module are noted. For example maxi current per point. Check with your application.
Red color indicates that there are no direct replacements but there are workarounds. Please consult Schneider Electric for assistance.
1
2
3
4
5
6
7
8
9
10
2/40
1
2
3
4
5
6
7
8
9
10
3/1
Communication selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/2
3.1 -
Ethernet Modbus/TCP and Ethernet/IP networks
Ethernet Modbus/TCP communication services
b
Introduction
v ..................................................3/8
Functions
v ....................................................3/9
Web services
b
Standard Web services
v ........................................3/14
FactoryCast
v Web services ....................................3/15
Web Designer conguration software
v . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/16
SOAP/XML Web services
v ......................................3/17
Processors with integrated Ethernet Modbus/TCP port
b
Introduction, description, references
v ..............................3/18
Ethernet Modbus/TCP network modules
b
Introduction, description, references
v ..............................3/19
Modbus/TCP and Ethernet/IP network module
b
Introduction, functions, description
v ................................3/20
References
v .................................................3/21
3.2 - RTU communication systems
Introduction
b ...................................................3/22
Functions, description
b ...........................................3/24
References
b ...................................................3/25
3.3 - ConneXium cabling systems for Ethernet
and Wi-Fi networks
ConneXium cabling systems for Ethernet networks
b
Selection guide .................................................3/26
Infrastructure
v ...............................................3/38
Connection components
v .......................................3/40
Hub and transceiver
v ...........................................3/42
Unmanaged switches
v ..........................................3/43
Managed switches
v ............................................3/45
ConneXium cabling systems for Wi-Fi networks
b
Selection guide .................................................3/48
Wi-Fi access points and clients
v ..................................3/58
Wi-Fi antennas, cables and accessories
v ...........................3/59
3.4 - Modbus Plus network
Introduction
b ...................................................3/60
References
b ...................................................3/61
3.5 - Probus DP bus
Introduction
b ...................................................3/62
References
b ...................................................3/63
3.6 - CANopen machine and installation bus
Introduction
b ...................................................3/64
References
b ...................................................3/66
Cabling systems
b. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/67
3.7 - AS-Interface bus
Introduction
b ...................................................3/70
References
b ...................................................3/71
3.8 - Modbus and Character mode serial links
Introduction
b ...................................................3/72
Complementary Specications
b ....................................3/74
References
b ...................................................3/75
Cabling system
b ............................................... 3/76
Communication
Contents chapter 3
1
2
3
4
5
6
7
8
9
10
3/2
Selection guide Modicon M340
automation platform
Communication, integrated ports and modules
Applications Ethernet communication Ethernet communication RTU communication
Type of device Processors with integrated
Modbus/TCP port
Ethernet modules Ethernet modules RTU module
Network protocols Ethernet Modbus/TCP Ethernet/IP and Modbus/TCP Modbus/TCP, IEC 60870-5-104,
DNP3 (subset level 3)
Serial link, External modem link,
IEC 60870-5-101, DNP3 (subset level 3)
Structure Physical interface 10BASE-T/100BASE-TX 10BASE-T/100BASE-TX 10BASE-T/100BASE-TX (Modbus/TCP),
PPPoE (Point-to-Point Protocol over Ethernet)
for ADSL external modem link
Non-isolated RS 232/485 (Serial link),
Non-isolated RS 232 (Radio, PSTN, GSM,
GPRS/3G external modem link)
Type of connector RJ45 Four RJ45 connectors (2 connectors for a ring topology) One RJ45 connector One RJ45 connector
Access method CSMA-CD CSMA-CD CSMA-CD (Modbus/TCP),
Master/slave (IEC 104/DNP3)
Master/slave (IEC 101/DNP3)
Data rate 10/100 Mbps 10/100 Mbps 10/100 Mbps (Modbus/TCP) 0.3 to 38.4 Kbps (Serial link)
Medium Double twisted pair copper cable, category CAT 5E
Optical ber via ConneXium cabling system
Double twisted pair copper cable, category CAT 5E, optical ber via ConneXium cabling system Double shielded twisted pair copper cable,
Crossover serial cable (Serial link),
Direct serial cable (External modem link)
Conguration Maximum number of devices 128 (Ethernet/IP or Modbus/TCP) 128 (Modbus/TCP),
32 slaves/servers (IEC 104/DNP3)
32 max.
Max. length 100 m (copper cable), 4000 m (multi-mode optical ber), 32,500 m (single-mode optical ber) 100 m (copper cable), 4000 m (multi-mode optical ber), 32,500 m (single-mode optical ber) 15 m (Non-isolated serial link),
1000 m (Serial link with insulating case)
Number of modules of the same type
per station
1 2 Ethernet or RTU modules per station with any
BMXP34processor
2 Ethernet or RTU modules per station with any BMXP34processor Depending on application-specic channels
(20/36 application-specic channels with
BMXP341000/P34 2pppp)
Standard services Modbus/TCP messaging Ethernet/IP and Modbus/TCP messaging Modbus/TCP messaging Reading/writing digital and analog I/O, counters
Transparent Ready conformity class B10 B30 C30 B30 C30
Embedded Web
server services
Standard services Rack Viewer PAC diagnostics, Data Editor access to PAC data and variables Rack Viewer PAC diagnostics, Data Editor access to PAC data and variables
Congurable services Alarm Viewer and
Graphic Data Editor
– –
Hosting and display of user
Web pages (14 MB)
Hosting and display of user Web pages
Transparent Ready™
communication
services
I/O Scanning service Yes Yes
Global Data service Yes
NTP time synchronization Yes (module version u 2.0) Yes
FDR service Yes (client) Yes (client/server) Yes (client/server) Yes (client)
SMTP e-mail notication service Yes, via EF function block
Unity Pro u 4.0
Yes –
SOAP/XML Web service – – Server Server
SNMP network management service Yes Yes Yes Yes (agent)
RSTP redundancy service Yes
QoS (Quality of Service) service Yes
RTU communication
services
IEC 60870-5-104,
DNP3 IP or
IEC 60870-5-101,
DNP3 serial
Master or Slave conguration Yes, IEC101/104 and DNP3
Time and date stamped data exchange Interrogation via polling and exchanges on change of status (RBE), unsolicited messaging
RTU time synchronization Yes, IEC101/104 and DNP3
Management and buffering of time
and date stamped events
Yes, IEC101/104 and DNP3
Automatic transfer of time and date
stamped events to the Master/SCADA
Yes, IEC101/104 and DNP3
Buffer holding 10,000 events (per connected client, 4 clients max.)
Data Logging service – – – Yes, on SD 128 MB memory card, in CSV les, access via FTP or sent by e-mail
Compatibility with processor Standard and Performance (see page 1/2) Standard and Performance (see page 1/2)
Processor or module
references depending
on other type of
integrated port
No other integrated port BMXNOE0100 BMXNOE0110 BMXNOC0401
Serial link BMXP342020 BMXNOR0200H
Ethernet Modbus/TCP BMXNOR0200H
CANopen BMXP3420302
Page 3/18 3/19 3/21 3/25
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/3
Applications Ethernet communication Ethernet communication RTU communication
Type of device Processors with integrated
Modbus/TCP port
Ethernet modules Ethernet modules RTU module
Network protocols Ethernet Modbus/TCP Ethernet/IP and Modbus/TCP Modbus/TCP, IEC 60870-5-104,
DNP3 (subset level 3)
Serial link, External modem link,
IEC 60870-5-101, DNP3 (subset level 3)
Structure Physical interface 10BASE-T/100BASE-TX 10BASE-T/100BASE-TX 10BASE-T/100BASE-TX (Modbus/TCP),
PPPoE (Point-to-Point Protocol over Ethernet)
for ADSL external modem link
Non-isolated RS 232/485 (Serial link),
Non-isolated RS 232 (Radio, PSTN, GSM,
GPRS/3G external modem link)
Type of connector RJ45 Four RJ45 connectors (2 connectors for a ring topology) One RJ45 connector One RJ45 connector
Access method CSMA-CD CSMA-CD CSMA-CD (Modbus/TCP),
Master/slave (IEC 104/DNP3)
Master/slave (IEC 101/DNP3)
Data rate 10/100 Mbps 10/100 Mbps 10/100 Mbps (Modbus/TCP) 0.3 to 38.4 Kbps (Serial link)
Medium Double twisted pair copper cable, category CAT 5E
Optical ber via ConneXium cabling system
Double twisted pair copper cable, category CAT 5E, optical ber via ConneXium cabling system Double shielded twisted pair copper cable,
Crossover serial cable (Serial link),
Direct serial cable (External modem link)
Conguration Maximum number of devices 128 (Ethernet/IP or Modbus/TCP) 128 (Modbus/TCP),
32 slaves/servers (IEC 104/DNP3)
32 max.
Max. length 100 m (copper cable), 4000 m (multi-mode optical ber), 32,500 m (single-mode optical ber) 100 m (copper cable), 4000 m (multi-mode optical ber), 32,500 m (single-mode optical ber) 15 m (Non-isolated serial link),
1000 m (Serial link with insulating case)
Number of modules of the same type
per station
1 2 Ethernet or RTU modules per station with any
BMXP34processor
2 Ethernet or RTU modules per station with any BMXP34processor Depending on application-specic channels
(20/36 application-specic channels with
BMXP341000/P34 2pppp)
Standard services Modbus/TCP messaging Ethernet/IP and Modbus/TCP messaging Modbus/TCP messaging Reading/writing digital and analog I/O, counters
Transparent Ready conformity class B10 B30 C30 B30 C30
Embedded Web
server services
Standard services Rack Viewer PAC diagnostics, Data Editor access to PAC data and variables Rack Viewer PAC diagnostics, Data Editor access to PAC data and variables
Congurable services Alarm Viewer and
Graphic Data Editor
– –
Hosting and display of user
Web pages (14 MB)
Hosting and display of user Web pages
Transparent Ready™
communication
services
I/O Scanning service Yes Yes
Global Data service Yes
NTP time synchronization Yes (module version u 2.0) Yes
FDR service Yes (client) Yes (client/server) Yes (client/server) Yes (client)
SMTP e-mail notication service Yes, via EF function block
Unity Pro u 4.0
Yes –
SOAP/XML Web service – – Server Server
SNMP network management service Yes Yes Yes Yes (agent)
RSTP redundancy service Yes
QoS (Quality of Service) service Yes
RTU communication
services
IEC 60870-5-104,
DNP3 IP or
IEC 60870-5-101,
DNP3 serial
Master or Slave conguration Yes, IEC101/104 and DNP3
Time and date stamped data exchange Interrogation via polling and exchanges on change of status (RBE), unsolicited messaging
RTU time synchronization Yes, IEC101/104 and DNP3
Management and buffering of time
and date stamped events
Yes, IEC101/104 and DNP3
Automatic transfer of time and date
stamped events to the Master/SCADA
Yes, IEC101/104 and DNP3
Buffer holding 10,000 events (per connected client, 4 clients max.)
Data Logging service – – – Yes, on SD 128 MB memory card, in CSV les, access via FTP or sent by e-mail
Compatibility with processor Standard and Performance (see page 1/2) Standard and Performance (see page 1/2)
Processor or module
references depending
on other type of
integrated port
No other integrated port BMXNOE0100 BMXNOE0110 BMXNOC0401
Serial link BMXP342020 BMXNOR0200H
Ethernet Modbus/TCP BMXNOR0200H
CANopen BMXP3420302
Page 3/18 3/19 3/21 3/25
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/4
Selection guide (continued) Modicon M340
automation platform
Communication, integrated ports and modules
Applications CANopen communication AS-Interface
communication
Serial link communication
Type of device Processors
with integrated CANopen port
AS-Interface
actuator/sensor bus module
Processors
with integrated serial link
2-channel serial link
module
Network protocols CANopen AS-Interface Modbus and Character mode
Structure Physical interface ISO 11898 (9-way SUB-D connector) AS-Interface V3 standard Non-isolated RS 232, 4-wire
Non-isolated RS 485, 2-wire
Non-isolated RS 232, 8-wire
Isolated RS 485, 2-wire
Type of connector 9-way SUB-D 3-way SUB-D RJ45 2 RJ45 and 1 RJ45
Access method CSMA/CA (multiple access) Master/slave Master/slave with Modbus link,
Full duplex (RS 232)/Half duplex (RS 485) in Character mode
Data rate 20 Kbps to 1 Mbps depending on distance 167 Kbps 0.3 to 38.4 Kbps 0.3 to 115.2 Kbps in RS 232
0.3 to 57.6 Kbps in RS 485
Medium Double shielded twisted pair copper cable Two-wire AS-Interface cable Double shielded twisted pair copper cable Shielded twisted pair copper cable
Conguration Maximum number of devices 63 depending on the devices connected 62 slaves 32 per segment, 247 max.
Max. length 20 m (1 Mbps) to 2500 m (20 Kbps) 100 m,
500 m max. with 2 repeaters
15 m (non-isolated),
1000 m with insulating case
15 m with non-isolated RS 232,
1000 m with non-isolated RS 485
Number of links of the same type per
station
1 BMXP341000 processor:
2 AS-Interface modules
120/36 application-specic channels with BMXP341000/P34 2pppp
(1 application-specic channel = 1 counter, motion control module or serial link
channel)
BMXP3420p0 processor:
4 AS-Interface modules
Standard services PDO implicit exchange (application data)
SDO explicit exchange (service data)
Transparent exchanges with
the sensors/actuators
Read/write bits and words, diagnostics in Modbus mode
Send and receive character string in Character mode
Conformity class Class M20 M4 prole
SMTP service
notication by e-mail
Yes, via EF function block
Unity Pro u 4.0
– –
Compatibility with processor Standard and Performance
(see page 1/2)
Standard and Performance (see page 1/2)
Type of processor or
module depending
on other integrated
port
None BMXEIA0100 BMXP341000/2000
Serial link BMXP3420102 BMXNOM0200
Ethernet Modbus/TCP BMXP3420302 BMXP342020
CANopen BMXP3420102
Page 3/66 3/71 3/75
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/5
Applications CANopen communication AS-Interface
communication
Serial link communication
Type of device Processors
with integrated CANopen port
AS-Interface
actuator/sensor bus module
Processors
with integrated serial link
2-channel serial link
module
Network protocols CANopen AS-Interface Modbus and Character mode
Structure Physical interface ISO 11898 (9-way SUB-D connector) AS-Interface V3 standard Non-isolated RS 232, 4-wire
Non-isolated RS 485, 2-wire
Non-isolated RS 232, 8-wire
Isolated RS 485, 2-wire
Type of connector 9-way SUB-D 3-way SUB-D RJ45 2 RJ45 and 1 RJ45
Access method CSMA/CA (multiple access) Master/slave Master/slave with Modbus link,
Full duplex (RS 232)/Half duplex (RS 485) in Character mode
Data rate 20 Kbps to 1 Mbps depending on distance 167 Kbps 0.3 to 38.4 Kbps 0.3 to 115.2 Kbps in RS 232
0.3 to 57.6 Kbps in RS 485
Medium Double shielded twisted pair copper cable Two-wire AS-Interface cable Double shielded twisted pair copper cable Shielded twisted pair copper cable
Conguration Maximum number of devices 63 depending on the devices connected 62 slaves 32 per segment, 247 max.
Max. length 20 m (1 Mbps) to 2500 m (20 Kbps) 100 m,
500 m max. with 2 repeaters
15 m (non-isolated),
1000 m with insulating case
15 m with non-isolated RS 232,
1000 m with non-isolated RS 485
Number of links of the same type per
station
1 BMXP341000 processor:
2 AS-Interface modules
120/36 application-specic channels with BMXP341000/P34 2pppp
(1 application-specic channel = 1 counter, motion control module or serial link
channel)
BMXP3420p0 processor:
4 AS-Interface modules
Standard services PDO implicit exchange (application data)
SDO explicit exchange (service data)
Transparent exchanges with
the sensors/actuators
Read/write bits and words, diagnostics in Modbus mode
Send and receive character string in Character mode
Conformity class Class M20 M4 prole
SMTP service
notication by e-mail
Yes, via EF function block
Unity Pro u 4.0
– –
Compatibility with processor Standard and Performance
(see page 1/2)
Standard and Performance (see page 1/2)
Type of processor or
module depending
on other integrated
port
None BMXEIA0100 BMXP341000/2000
Serial link BMXP3420102 BMXNOM0200
Ethernet Modbus/TCP BMXP3420302 BMXP342020
CANopen BMXP3420102
Page 3/66 3/71 3/75
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/6
Selection guide (continued) Modicon M340
automation platform
Communication, integrated ports and modules
Applications Modbus Plus communication Probus DP and Probus PA communication
Type of device M340 Modbus Plus proxy module (external) Probus Remote Master (PRM) module (external)
Network protocols Ethernet Modbus/TCP Modbus Plus Ethernet Modbus/TCP Probus DP V1
Probus PA (via gateway)
Structure Physical interface 10/100BASE-T Modbus Plus standard 10BASE-T/100BASE-TX Isolated RS 485
Type of connector Two RJ45 connectors Two 9-way female SUB-D connectors Two RJ45 connectors (supporting daisy chain topology) One 9-way female SUB-D connector
Access method CSMA-CD Token ring CSMA-CD Master/slave
Data rate 10/100 Mbps 1 Mbps 10/100 Mbps 9.6 Kbps to 12 Mbps
Medium Double shielded twisted pair copper cable,
category CAT 5E (direct or crossover)
Twisted pair copper cable Double shielded twisted pair copper cable,
category CAT 5E (direct or crossover)
Shielded twisted pair copper cable
Conguration Maximum number of devices 128 32 per segment
64 maximum for multiple segments
Several PRMs can be connected to the Ethernet port on the M340, Premium or
Quantum PAC, as long as the I/O scanner capacity is not exceeded
125 slaves
Max. length 100 m 450 m per segment
1800 m with 3 repeaters
100 m (copper) 1200 (9.6 Kbps), 4800 m with 3 repeaters,
100 m (12 Mbps), 400 m with 3 repeaters
Number of links of the same
type per station
1 max.
Standard services Modbus/TCP messaging Modbus Plus messaging Modbus/TCP messaging Cyclic and acyclic data exchange with slaves
Conformity class Transparent Ready Class A20 Class 1 and Class 2
Embedded Web server
service
Standard service Conguration, diagnostics
Congurable services – –
Communication services Modbus Plus server (scanned by the PAC) Reading/writing variables Modbus server (scanned by the PAC) Master/slave communication
FDR service Global database FDR service Global Control service
SNMP agent network management service Peer Cop service SNMP agent network management service Acyclic communication (read/write) in Class 1 and Class 2
Support for extended diagnostics
Auto-scanning service of slaves on the bus
24 V c external power supply 19.2 to 31.2 V 18 to 30 V
Module types TCSEGDB23F24FA TCSEGPA23F14F
Page 3/61 3/63
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/7
Applications Modbus Plus communication Probus DP and Probus PA communication
Type of device M340 Modbus Plus proxy module (external) Probus Remote Master (PRM) module (external)
Network protocols Ethernet Modbus/TCP Modbus Plus Ethernet Modbus/TCP Probus DP V1
Probus PA (via gateway)
Structure Physical interface 10/100BASE-T Modbus Plus standard 10BASE-T/100BASE-TX Isolated RS 485
Type of connector Two RJ45 connectors Two 9-way female SUB-D connectors Two RJ45 connectors (supporting daisy chain topology) One 9-way female SUB-D connector
Access method CSMA-CD Token ring CSMA-CD Master/slave
Data rate 10/100 Mbps 1 Mbps 10/100 Mbps 9.6 Kbps to 12 Mbps
Medium Double shielded twisted pair copper cable,
category CAT 5E (direct or crossover)
Twisted pair copper cable Double shielded twisted pair copper cable,
category CAT 5E (direct or crossover)
Shielded twisted pair copper cable
Conguration Maximum number of devices 128 32 per segment
64 maximum for multiple segments
Several PRMs can be connected to the Ethernet port on the M340, Premium or
Quantum PAC, as long as the I/O scanner capacity is not exceeded
125 slaves
Max. length 100 m 450 m per segment
1800 m with 3 repeaters
100 m (copper) 1200 (9.6 Kbps), 4800 m with 3 repeaters,
100 m (12 Mbps), 400 m with 3 repeaters
Number of links of the same
type per station
1 max.
Standard services Modbus/TCP messaging Modbus Plus messaging Modbus/TCP messaging Cyclic and acyclic data exchange with slaves
Conformity class Transparent Ready Class A20 Class 1 and Class 2
Embedded Web server
service
Standard service Conguration, diagnostics
Congurable services – –
Communication services Modbus Plus server (scanned by the PAC) Reading/writing variables Modbus server (scanned by the PAC) Master/slave communication
FDR service Global database FDR service Global Control service
SNMP agent network management service Peer Cop service SNMP agent network management service Acyclic communication (read/write) in Class 1 and Class 2
Support for extended diagnostics
Auto-scanning service of slaves on the bus
24 V c external power supply 19.2 to 31.2 V 18 to 30 V
Module types TCSEGDB23F24FA TCSEGPA23F14F
Page 3/61 3/63
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/8
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Ethernet Modbus/TCP network
Ethernet Modbus/TCP communication services
Introduction
Introduction
BMXP342020/20302 processors via their integrated Ethernet port…
BMXNOE0100/0110 network modules…and the BMXNOR0200H RTU module… all
provide transparent communication on the Ethernet Modbus/TCP network using
Transparent Ready communication services.
SMTP Modbus
HTTPFTP
TFTP
DHCPRTPS
NTP
SNMP
UDP TCP
Physical
Network
management
FDR Faulty Device Replacement Messaging
Link
Transport
Applications
Services
Ethernet 802.3 and Ethernet II
Time
synchro-
nization
Web
server
Global
Data
E-mail I/O
Scanning
MIB 2 standard
MIB Transparent Ready
IP
The following Transparent Ready communication services are designed for use in
automation applications. They supplement the universal Ethernet services (HTTP,
BOOTP/DHCP, FTP, etc):
Modbus/TCP messaging for class 10 or 30 devices
b
I/O Scanning service for class 30 devices
b
FDR (Faulty Device Replacement) for class 10 or 30 devices
b
SNMP
b (Simple Network Management Protocol) network management for class 10
or 30 devices
Global Data, for class 30 devices
b
Bandwidth management for class 10 or 30 devices
b
NTP (
b Network Time Protocol) synchronization for class 30 devices
E-mail detected alarm notication via SMTP server, via Unity Pro function block
b
Note: See selection guide on page 3/2 for the communication services supported by
BMXP342020/20302 processors, BMXNOE0100/0110 network modules and the
BMXNOR0200H RTU module on the Modicon M340 platform.
The following pages (3/9 to 3/13) present the various options available through these
services to facilitate the optimum choice of solutions when dening a system
integrating Transparent Ready devices.
Ethernet communication services for the BMXNOE0100/0110 module
1
2
3
4
5
6
7
8
9
10
3/9
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Ethernet Modbus/TCP network
Ethernet Modbus/TCP communication services
Functions
Functions
Ethernet universal services
The Modicon M340 automation platform utilizes the following universal
Ethernet services:
HTTP b(HyperText Transfer Protocol):
This protocol is used for transmitting Web pages between a server and a browser. v
Web servers embedded in Transparent Ready v automation products provide
easy access to products located anywhere in the world from a standard web
browser such as Internet Explorer.
BOOTP/DHCP b (RFC1531):
These protocols are used to provide devices with IP parameters automatically. v
This avoids having to manage each device address individually by transferring this
management to a dedicated IP address server.
The DHCP protocol v(Dynamic Host Conguration Protocol) is used to assign
conguration parameters to devices automatically. DHCP is an extension
of BOOTP.
Schneider Electric devices can be vBOOTP clients” (used to retrieve the IP
address automatically from a server) or “BOOTP servers” (allowing the device to
distribute IP addresses to the network stations).
Schneider Electric uses standard BOOTP/DHCP protocols for its FDR v(Faulty
Device Replacement) service.
FTP b(File Transfer Protocol) (RFCs 959, 2228, and 2640):
This protocol provides the basic elements for le sharing. Many systems use it v
to exchange les between devices.
TFTP b(Trivial File Transfer Protocol) (RFCs 959, 2228, and 2640):
This network transfer protocol can be used to connect to a device and download v
code to it.
For example, it can be used to transfer a boot code to a workstation without a v
disk drive or to connect and download updates of network device rmware.
Transparent Ready devices implement FTP and TFTP for transferring certain v
information to or from devices, in particular for downloads of rmware or user-
dened Web pages.
SNMP b (Simple Network Management Protocol) (RFCs 1155, 1156 and 1157):
The SNMP standard manages the various network components via a v
single system.
The network management system can exchange data with SNMP agent v
devices. This function allows the manager to display the status of the network and
devices, modify their conguration and feed back detected alarms in the event of a
detected fault.
Transparent Ready devices are SNMP-compatible and can be integrated v
naturally in a network managed via SNMP.
COM/DCOM b (Distributed Component Object Model) (RFCs 1155, 1156 and 1157):
COM/DCOM or OLE v(Object Linking and Embedding) protocol is the name of
the technology consisting of Windows objects that enable transparent
communication between Microsoft Windows® applications.
These technologies are used in the OFS ( vOLE for Process Control Factory
Server) data server software.
.Modbus standard communication protocol
Modbus protocol, the industry communication standard since 1979, has been
combined with Ethernet Modbus/TCP, the medium for the Internet revolution, to form
Modbus/TCP, a completely open Ethernet protocol.
The development of a connection to Modbus/TCP does not require any proprietary
component, nor purchase of a license.
This protocol can easily be combined with any product supporting a standard TCP
communication stack. The specications can be obtained free of charge from the
following website: www.modbus-ida.org.
1
2
3
4
5
6
7
8
9
10
3/10
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Ethernet Modbus/TCP network
Ethernet Modbus/TCP communication services
Functions (continued)
I/O Scanning Service
I/O Scanning Service is used to manage the exchange of remote I/O states on the
Ethernet network after a simple conguration operation, with no need for special
programming.
I/O scanning is performed transparently by means of read/write requests according
to the Modbus client/server protocol on the TCP prole.
This principle of scanning via a standard protocol enables a device with the I/O
Scanning service to communicate with any device supporting Modbus TCP
messaging in server mode.
This service can be used to dene:
A word zone reserved for reading inputs
b
A word zone reserved for writing outputs
b
Refresh periods independent of the PAC scan
b
During operation, the module:
Manages TCP connections with each remote device
b
Scans devices and copies the I/O to the congured word zone
b
Feeds back status words used to check that the service is working correctly from
b
the PAC application
Applies pre-congured fallback values if a communication become inoperative
b
A range of hardware and software products is available enabling the I/O Scanning
protocol to be implemented on any type of device that can be connected to the
Ethernet network (please consult the Modbus-IDA website: www.modbus-ida.org.
Specications
Each Modicon M340 station can exchange a maximum of 100 words for writing
b
and 125 words for reading.
Maximum size in the Modicon M340 PAC that manages the service (64 stations
b
max.) with BMXNOE0100/0110 and BMXNOC0401 network modules: 2 Kwords
(input) and 2 Kwords (output).
I/O Scanning service diagnostics
I/O Scanning service diagnostics can be performed in one of ve ways:
Via the application program from a specic PAC data zone
b
From the setup software debug screen
b
From the PAC system diagnostic function displayed by means of an internet
b
browser on a PC station
Using the
b TCSEAZ01PSFE10 ConneXview diagnostic software
Using standard SNMP manager software
b
2
1
22
Word table
Read Write
Ethernet Modbus/TCP
Input words
Output words
of devices
Functions (continued)
2 Device with Modbus TCP messaging in server mode
1 Modicon M340 device with I/O Scanning service
1
2
3
4
5
6
7
8
9
10
3/11
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Ethernet Modbus/TCP network
Ethernet Modbus/TCP communication services
Functions (continued)
FDR (Faulty Device Replacement) service
Faulty Device Replacement service uses standard address management
technologies (BOOTP, DHCP) and the TFTP (Trivial File Transfer Protocol) le
management service, to simplify the maintenance of Ethernet devices.
FDR service is used to replace an inoperative device with a new device that will be
detected, recongured and automatically rebooted by the system.
The main steps in replacement are:
Device using the FDR service becomes inoperative.1
Another similar device is taken from the maintenance store, precongured with 2
the Device name for the inoperative device, then reinstalled on the network.
Depending on the device, addressing can be performed using rotary selector
switches (as for Modicon STB distributed I/O a, or Modicon OTB for example)
or can be given using the keypad integrated in the device (as for Altivar variable
speed drives for example).
The FDR server detects the new device, allocates it an IP address and transfers 3
the conguration parameters to it.
The substituted device checks that these parameters are compatible with its own 4
specications and switches to operational mode.
The FDR server can be the BMXNOE0100/0110 Ethernet module or the
BMXNOC0401 module.
NTP time synchronization service
Introduction
BMXCPS
power
supply
Processor BMXNOE
module
Internal
clock
Ethernet network
NTP
server
Modicon M340
NTP response
NTP request
NTP
client
The time synchronization service is based on the NTP (Network Time Protocol) that
is used to synchronize the time of a client or a server on Ethernet from a server or
another reference time source (radio, satellite, etc).
Operation
BMXNOE0100/0110, BMXNOC0401 and BMXNOR0200H Ethernet Modbus/TCP
modules have an NTP client component.
These modules connect to an NTP server using a client request (Unicast) to update
their local time. The module clock is updated periodically (1 to 120 s) with typical
precision of 5 ms. If the NTP server cannot be reached, the Ethernet TCP/IP module
switches to a standby NTP server.
The PAC processor clock is updated with a precision of 5 ms. A function block is
used to read this clock, thus enabling Unity Pro application events or variables to be
time and date stamped.
The Ethernet module is congured by means of a Web page. The time zone can be
congured. A time synchronization service (NTP) diagnostic Web page is also available.
Information on the time synchronization service (NTP) is also available in the
Transparent Ready private MIB that can be accessed via the SNMP network
management service.
a
NIM network module for
Modicon STB I/O
1
2
3
4
5
6
7
8
9
10
3/12
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Ethernet Modbus/TCP network
Ethernet Modbus/TCP communication services
Functions (continued)
Functions (continued)
Global Data service
The Global Data service performs data exchanges in real-time between stations
belonging to the same distribution group. It is used to synchronize remote applications,
or to share a common database between a number of distributed applications.
Exchanges are based on a standard producer/consumer protocol, guaranteeing
optimum performance with a minimum load on the network. This RTPS (Real Time
Publisher Subscriber) protocol is promoted by Modbus-IDA (Interface for Distributed
Automation), and is already a standard adopted by several manufacturers.
Specications
A maximum of 64 stations can participate in Global Data within a single distribution
group. Each station can:
Publish one 1024-byte variable. The publication period can be congured from 1 b
to n processor master task (Mast) periods.
Subscribe to between 1 and 64 variables. The validity of each variable is controlled b
by status bits (Health Status bits) linked to a refresh timeout congurable between
50 ms and 1s. Access to an element of the variable is not possible. The maximum
size of subscribed variables amounts to 4 K contiguous bytes.
To further optimize the performance of the Ethernet network, Global Data can be
congured with the “multicast ltering” option that, together with switches in the
ConneXium range (see page 3/26), broadcasts data only to Ethernet ports where
there is a Global Data service subscriber station. If these switches are not used,
Global Data is sent in “multicast” mode to each switch port.
Global Data service diagnostics
The diagnostic screens use a color code to show the Global Data status:
Congured/not congured/inoperative.
b
Published/subscribed.
b
Global Data service diagnostics can be performed in one of ve ways:
Via the application program from a specic PAC data zone.
b
From the setup software debug screen.
b
From the PAC system diagnostic function displayed by means of an internet
b
browser on a PC station.
Using the
b TCSEAZ01PSFE10 ConneXview diagnostic software.
Using standard SNMP manager software.
b
Modicon
Quantum
PAC
Modicon
Premium
PAC
Modicon
Premium
PAC
Modicon
M340
PAC
Distribution group 1
Data exchange 4 KB max.
Data exchange 4 KB max.
Distribution group 2
IP multicast 239.255.255.251
IP multicast 239.255.255.250
Ethernet Modbus/TCP
1
2
3
4
5
6
7
8
9
10
3/13
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Ethernet Modbus/TCP network
Ethernet Modbus/TCP communication services
Functions (continued)
Functions (continued)
SNMP network management service
From a network management station, SNMP (Simple Network Management Protocol)
monitors and checks components of the Ethernet architecture and thus helps
ensures quick diagnostics.
It is used to:
Interrogate network components such as computer stations, routers, switches,
b
bridges or terminal devices to view their status.
Obtain statistics about the network to which the devices are connected.
b
This network management software complies with the conventional client/server
model. However, to avoid confusion with other communication protocols that use this
terminology, we talk instead about:
ConneXview
b network diagnostics software, TCSEAZ01PSFE10. For more
information, please refer to the “Machines and installations, industrial communication
networks” catalog.
Network manager for the client application that operates on the computer station.
b
SNMP agent for the network device server application.
b
Transparent Ready devices can be managed by any SNMP network manager,
including HP Openview and IBM Netview.
Standard SNMP (Simple Network Management Protocol) is used to access
conguration and management objects contained in the device MIBs (Management
Information Bases). These MIBs comply with specic standards to allow access by
any commercially-available manager, but depending on the complexity of products,
manufacturers can add certain objects to private databases.
The Transparent Ready private MIB presents management objects specic to the
Schneider Electric offer. These objects simplify the installation, setup and
maintenance of Transparent Ready devices in an open environment using standard
network management tools.
Transparent Ready devices support 2 levels of SNMP network management:
The Standard MIB II interface: This interface accesses a rst level of network
b
management. It enables the manager to identify the devices making up the
architecture and retrieve general information about the conguration and operation
of Ethernet Modbus/TCP interfaces.
The Transparent Ready MIB interface: This interface improves the management
b
of Transparent Ready devices. This MIB has a set of data enabling the network
management system to supervise the Transparent Ready services.
The Transparent Ready MIB can be downloaded from the FTP server of any
Transparent Ready Ethernet module to a PAC.
Automatic recognition of IP devices via the ConneXview
diagnostic software for Ethernet industrial networks
1
2
3
4
5
6
7
8
9
10
3/14
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Ethernet Modbus/TCP network
Standard Web services
Introduction of Web services
Standard Web server functions are integrated in a wide variety of Schneider Electric
Ethernet products: Modicon automation platform processors and Ethernet
modules, distributed I/O modules, variable speed drives and gateways. These
functions are mainly integrated in BMXP342020/20302 processors, in
BMXNOE0100/ 0110 and BMXNOC0401 Ethernet network modules, in the
BMXNOR0200H RTU module, and the TCSEGDB23F24FA Modbus Plus proxy
module on the Modicon M340 platform.
From a simple Internet browser, the standard Web server authorizes the following
“ready-to-use” functions:
Remote diagnostics and maintenance of products
b
Display and adjustment of products (read/write variables, status)
b
With the BMXNOE0110 FactoryCast module equipped as standard with the
BMXRWSFC032M card, the Web server also offers the following functions:
Management of PAC system and application detected alarms with partial or
b
complete acknowledgement (ready-to-use Alarm Viewer function pages)
Hosting and display of Web pages created by the user
b
The embedded Web server is a real-time data server. Data can be presented in the
form of standard Web pages in HTML format and can therefore be accessed using
any Web browser that supports the embedded Java® code. The standard functions
provided by the Web server are supplied “ready-to-use” and do not require
programming of either the PAC or the client PC device supporting a Web browser.
Standard Web server on the Modicon M340 platform
Rack Viewer PAC diagnostics function
The Rack Viewer function can be used for PAC system and I/O diagnostics. It
displays the following in real time:
Status of LEDs on the PAC front panel
b
PAC type and version
b
Hardware conguration of the PAC including status of the system bits and words
b
Detailed diagnostics of:
b
Each of the I/O module channels or application-specic channels in the v
conguration
Devices connected to the CANopen bus v
Data Editor read/write function for PAC data and variables
The Data Editor function can be used to create tables of animated variables for
real-time read/write access to PAC data in the form of lists.
Various animation tables containing specic application variables to be monitored or
modied can be created by the user and saved in the standard Web server module.
In addition to the functions provided by the standard
Web server, the BMXNOE0110 Ethernet module's
FactoryCast Web server offers the following:
b Display of variables: Variables can be entered and
displayed either in their symbolic form (S_Pump 234)
or as their address (%MW99).
b Write access to variables: This can be enabled or
disabled for each of the variables using the
FactoryCast module conguration software.
b Read/write function: This can be used on tools
such as a pocket PC or PDA terminal.
Modicon M340 hardware conguration
Data Editor variables table
Introduction,
functions
1
2
3
4
5
6
7
8
9
10
3/15
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Ethernet Modbus/TCP network
FactoryCast Web services
BMXNOE0100 module FactoryCast Web server
In addition to the standard services, the embedded Web server in the BMXNOE0110
FactoryCast module offers the functions described below.
Alarm Viewer function
The alarm viewer is a ready to use, password-protected function. It is used to
process detected alarms (display, acknowledgement and deletion) managed at PAC
level by the system or using diagnostic function blocks known as DFBs (system-
specic diagnostic function blocks and application-specic diagnostic function
blocks created by the user).
These detected alarms are stored in the diagnostic buffer managed by the Modicon
M340 platform (dedicated memory space for storing the diagnostic events).
The diagnostic viewer is a Web page is comprised of a list of messages that displays
the following information for each detected alarm:
Dates and times of the occurrence/removal of a detected fault
b
Alarm message
b
Alarm status
b
Type of associated diagnostic function block (DFB)
b
Graphic Data Editor function
This function is used to create the graphic views animated by the PAC variables that
can be accessed via their address or via their symbol (access to located data). The
ready-to-use graphic editor is available in online mode when connected to the
BMXNOE0110 module.
These views are created from a library of predened graphic objects by simple
copy/paste operations. The objects are congured to suit the user's requirements
(color, PAC variables, name, etc).
List of graphic objects available:
Analog and digital indicators
b
Horizontal and vertical bar charts
b
Boxes for displaying messages and entering values
b
Push button boxes
b
Trend recorders
b
Vats, valves, motors
b
Customized graphic objects can be added to this list and can be reused in user Web
pages that have been created using standard software for editing HTML pages. The
views thus created are saved in the BMXNOE0110 module and can be displayed
using any Web browser.
User Web page hosting and display function
The BMXNOE0110 FactoryCast module has a 16 Mbyte non-volatile memory that is
accessed in the same way as a hard drive. This allows hosting of Web pages and
any user-dened Microsoft Word or Adobe Acrobat Reader document (for example,
maintenance manuals, wiring diagrams).
Web pages can be created using any standard tool for creation and editing in HTML
format. They can be enhanced by inserting animated graphic objects linked to PAC
variables. These animated objects are created using the Graphic Data Editor. They
are then downloaded to the BMXNOE0110 module via the FactoryCast Web server
conguration software.
These user Web pages can be used, for example, to:
Display and modify PAC variables in real time
b
Create hyperlinks to other external Web servers (documentation, suppliers)
b
This function is particularly suitable for creating graphic interfaces used for the
following purposes:
Real-time display and supervision
b
Production monitoring
b
Diagnostics and help with maintenance
b
Operator guides
b
Alarm display from the diagnostic buffer
Library of predened graphic objects
Real-time supervision graphic interface
New screen pending
Functions (continued)
1
2
3
4
5
6
7
8
9
10
3/16
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Ethernet Modbus/TCP network
Web Designer conguration software
Web Designer conguration software
Web Designer conguration software is supplied on CD-ROM with the
BMXNOE0110, BMXNOC0401 Ethernet network modules and the
BMXNOR0200H RTU module.
The software is used for the conguration and administration of the Web server
embedded in the modules. It makes it easier to create customized Web human/
machine interfaces (HMIs). It is also used for easy conguration of embedded
advanced processing functions for numerous Web server modules and RTU modules:
FactoryCast™ Web server modules for Modicon
b M340, Quantum and
Premium PACs
FactoryCast HMI Web server modules for Modicon Premium and Quantum PACs
b
ETG 1000/3000 FactoryCast Gateways for remote access
b
RTU module for Modicon M340
b
Web Designer software is compatible with the Windows 2000 SP2, Windows XP
Professional and Windows Vista® Professional 32-bit operating systems.
For optimum use, it requires Java Virtual Machine 1.4.2 minimum.
Web Designer software offers the following functions:
Conguring the Web Designer function parameters
b :
Denition of access security, passwords v
Importing of PAC symbol databases v
Denition of access to write-enabled variables v
Management of the Web site
b :
Management of default site Web pages v
Management of user site Web pages v
Graphic Data Editor for animating Web pages v(BMXNOE0110 module only).
This integrated editor can be used for easy customization of graphic objects: bar
charts, gauges, LEDs, curves, cursors, operator input elds, alphanumeric display
elds, buttons, etc.
Downloading of Web pages between the PC and the module v
Debugging of Web pages in online mode or in simulation mode (including v
animations and Java beans)
Simulation mode
b :
The application and the Web site (including the Java animations) can be set up v
in online mode or in simulation mode.
Simulation mode is used to test the operation of the Web application without a v
module (with no physical connection to a PAC) simplifying debugging.
Creation of user Web pages
b :
User Web pages are created graphically using an external HTML editor v
(FrontPage or similar, not supplied).
User Web pages created with the graphic editor are actual animated v
supervisory control screens and can be used to monitor the process. Based on
Web technologies (HTML and Java), they provide real-time access to PAC
variables using the FactoryCast library of graphic objects (Java beans)
(BMXNOC0401 module only) (1).
Data Logging
b (for BMXNOR0200H module only):
This service is used to archive the application data: events, detected alarms, v
process data, device states, process values, etc.
Data is logged in CSV les in ASCII format that are stored locally on the SD v
memory card in the BMXNOR0200H module.
Sending detected alarm notications or reports via Email or SMS
b
BMXNOR0200H module only):
The BMXNOR0200H module can send e-mails or SMS messages v
automatically in real-time to send detected alarm notications, maintenance calls,
production reports or factory status updates, etc to specied users.
E-mails or SMS messages are sent when a predened application or process is v
triggered.
(1) Web Designer includes a plug-in for FrontPage 2000. This plug-in makes it easier to set up
animations for real-time access to the PAC variables in HTML pages created by the user.
They are created in the HTML editor by simply inserting customized graphic objects.
Functions (continued)
Graphic Data Editor
Conguring the Data Logging function for
BMXNOR0200H module
Web Designer
1
2
3
4
5
6
7
8
9
10
3/17
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Ethernet Modbus/TCP network
SOAP/XML Web services
SOAP/XML Web services
BMXNOE0110, BMXNOC0401 Ethernet network modules and BMXNOR0200H
RTU modules incorporate a standard SOAP/XML data server that provides direct
interoperability between control system devices and computer management
applications (MES, ERP, SAP, pNet application, etc).
SOAP/XML Web services embedded in the PAC
These Web services conform to W3C (World Wide Web Consortium) Web service
standards. They offer standard open communication resources allowing the control
peripherals to interact directly with computer management applications using a
non-proprietary SOAP protocol.
SOAP/XML Web services are based on the following standards:
SOAP
b (Simple Object Access Protocol), the exchange protocol executed via the
HTTP (HyperText Transfer Protocol) channel
WSDL
b (Web Services Description Language), in XML format
XML
b (eXtensible Markup Language), the universal standard for data exchange
ModbusXMLDa Web services: SOAP server interface
The implementation of ModbusXMLDa (Modbus XML Data access) services in
control system device Web servers means IT engineers can easily create their own
application to access the desired information directly in the PAC, in real time.
Applications such as Microsoft.NET, SQL Server®, Microsoft Ofce (Excel®), IBM®
(WebSphere®), SUN® (Java®, Eclipse), Lotus®, Oracle®, SAP®, MES, and ERP can
interact directly with the PAC module Web server.
Exchanges are initiated by the SOAP client application (the server responds to these
requests). Data exchanges are made in XML standard format in response to a request
using the SOAP protocol.
Step
b 1: Creation of the client application and the learning of the Web services.
The development environment (for example, Visual Studio® pNET) looks in the
FactoryCast server for the list of available services and their WSDL standard
interfaces provided by the module.
Step
b 2: Development of the client application. The developer integrates the
Web service functions using the code retrieved at step 1 of the learning process.
Step
b 3: Execution of the client application. The client application
communicates in real time with the FactoryCast Web server module using the
SOAP protocol.
Functions (continued)
1, 2
3
SOAP
request
WSDL
Visual Studio pNET
pNET Java
FactoryCast
module
BMXNOE0110
SOAP
server
Development tool
1
2
3
4
5
6
7
8
9
10
3/18
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Introduction,
description,
references
Modicon M340
automation platform
Processors with integrated Ethernet Modbus/
TCP port
Introduction
BMXP342020 and BMXP3420302 standard format Modicon M340 processors
(with integrated Ethernet port) occupy a single slot marked “00” in the rack on the
Modicon M340 platform.
Description
The front panel of BMXP342020/20302 Modicon M340 processors features:
Screw for locking the module in a slot in the rack.1
Display block with 8 LEDs, including 3 relating to the Ethernet port:2
ETH ACT LED (green): Activity on the Ethernet network v
ETH STS LED (green): Ethernet network status v
Depending on processor version:
Version 1 v: ETH 100 LED (green): data rate on the Ethernet network (10 or
100 Mbps)
Version 2 and later v: ETH LNK LED (green): Ethernet link status
Mini B USB connector for a programming terminal (or Magelis3 XBTGT/GK/
GTW HMI terminal).
Slot equipped with its Flash memory card for saving the application and 4
activating the standard Web server (Transparent Ready class B10).
RJ45 connector for the connection to the Ethernet network.5
Depending on model:
BMXP3420206 processor: An RJ45 connector for the Modbus serial link or
Character mode link (RS 232C/RS 485, 2-wire, non-isolated)
BMXP34203027 processor: A 9-way SUB-D connector for the master CANopen
machine and installation bus.
On the rear panel: 2 rotary switches for selecting the IP address using one of
3 assignment methods:
Address set by the position of the two switches v
Address set by the application parameters v
Address set by the Ethernet network BOOTP server v
References
Description I/O capacity
Memory capacity
Other integrated
communication ports
Reference Weight
kg
Processors with
integrated Ethernet
Modbus/TCP link
Transparent Ready
class B10
1024 discrete I/O
256 analog I/O
36 app-specic
channels 4096 KB
integrated
Modbus serial link
or Character mode
BMXP342020 0.205
CANopen bus BMXP3420302 0.215
BMXP342020 BMXP3420302
6
2
3
5
1
4
7
1
2
3
4
5
6
7
8
9
10
3/19
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Introduction,
description,
references
Modicon M340
automation platform
Ethernet Modbus/TCP network modules
Introduction
BMXNOE0100 and BMXNOE0110 standard format modules occupy a single slot in
the rack on the Modicon M340 platform equipped with a Standard or Performance
processor.
Description
The front panel of BMXNOE0100 and BMXNOE0110 modules features:
Screw for locking the module in a slot in the rack.1
Display block with 6 LEDs, including 3 relating to the Ethernet port:2
ETH ACT LED (green): Activity on the Ethernet network v
ETH STS LED (green): Ethernet network status v
Depending on processor version:
Version 1 v: ETH 100 LED (green): data rate on the Ethernet network (10 or 100
Mbps)
Version 2 and later v: ETH LNK LED (green): Ethernet link status
Slot equipped with its Flash memory card for saving the application and 3
activating the Web server (Transparent Ready class B30 or C30 depending on
the model).
RJ45 connector for connection to the Ethernet network.4
Pencil-point RESET push button for a cold restart of the module.5
On the rear panel: 2 rotary switches for assigning the IP address in one of three
ways:
Address set by the position of the two switches v
Address set by the application parameters v
Address set by the Ethernet network BOOTP server v
References
Description Data rate Transparent Ready
Class
Reference Weight
kg
Ethernet Modbus/
TCP network
modules
10/100 Mbps B30 BMXNOE0100 0.200
C30 BMXNOE0110(1) 0.200
Spare parts
Description Size Supplied
as standard with
Reference Weight
kg
Flash memory
cards
8 MB BMXNOE0100 BMXRWSB000M 0.002
32 MB BMXNOE0110 BMXRWSFC032M 0.002
(1) The Web Designer software is supplied on CD-ROM with the BMXNOE0110 module.
This software is used for the conguration and administration of the Web server embedded in
the module, see page 3/16.
5
2
4
1
3
BMXNOE0100/0110
1
2
3
4
5
6
7
8
9
10
3/20
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Introduction,
functions,
description
Modicon M340
automation platform
Modbus/TCP and Ethernet/IP network module
Introduction
The BMXNOC0401 network module acts as an interface between the M340 PAC
and other Ethernet network devices via the Modbus/TCP and Ethernet/IP
communication protocols.
The standard format BMXNOC0401 network module occupies a single slot in the
rack of the Modicon M340 platform. The BMXNOC0401 will function correctly with
either the Standard BMXP341000 or Performance BMXP342 processor.
Functions
The BMXNOC0401 module includes the following functions:
Modbus/TCP and Ethernet/IP protocols operating simultaneously. b
Ring topologies on 2 Ethernet ports using RSTP b(Rapid Spanning Tree Protocol).
Priority of Ethernet packets using QoS b(Quality of Service) service.
Automatic module conguration recovery using FDR b(Faulty Device Replacement)
service.
Support for SCADA functions via the OPC b protocol.
Embedded Web server for application monitoring and module diagnostics. b
Sharing data between PACs. b
Network management using SNMP b(Simple Network Management Protocol).
Description
The front panel of the BMXNOC0401 module features:
Screw for locking the module in a slot in the rack.1
Display block with 5 LEDs:2
RUN LED (green): Operating status
v
ERR LED (red): Error detected
v
MS LED (green/red): Module status
v
NS LED (green/red): Network connection status
v
ETH STS LED (amber): Ethernet link status
v
Four RJ45 connectors for connection to the Ethernet network. The two bottom 3
connectors 3b support ring topologies (RSTP protocol).
Each RJ45 connector has two associated LEDs:
LNK LED (yellow): Ethernet link established
v
ACT LED (green): Transmission/reception activity
v
On the rear panel, 2 rotary switches for selecting the IP address module using one
of 4 assignment methods:
IP address dened by the Ethernet network BootP server
v
IP address congured by the application parameters
v
Default IP address
v
IP address dened by the position of the 2 rotary switches
v
1
2
3b
3
1
2
3
4
5
6
7
8
9
10
3/21
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
References Modicon M340
automation platform
Modbus/TCP and Ethernet/IP network module
References
Description Data rate Transparent
Ready Class
Reference Weight
kg
Ethernet/IP,
Modbus/TCP
network module
10/100 Mbps B30 BMXNOC0401(1) 0.345
(1) The “Unity™ Pro conguration tool” software is supplied on CD-ROM with the module. This
software is used to update the Unity Pro hardware catalog (addition of the new module DTMs).
BMXNOC0401
1
2
3
4
5
6
7
8
9
10
3/22
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Introduction Modicon M340
automation platform
RTU communication systems
Introduction
RTU communication systems are designed to meet the needs of the water/waste
water industry, the oil and gas sector and other infrastructures, where remote
monitoring and telecontrol are required to manage sites and substations spread over
a wide geographical area.
RTU protocols and Telemetry systems provide communications suitable for the process
values, maintenance and remote monitoring needs of infrastructures disseminated
over a vast geographical area that may be difcult to access.
An RTU system consists of the following elements:
A Telemetry Supervisor (SCADA) in a central control room b
A network infrastructure and a variety of suitable communication methods b
(LAN, WAN, modems, etc)
A large number of RTU substations geographically distributed throughout the eld b
Ethernet 2
Ethernet 1
RTURTU
RTURTU
RTURTURTURTU
RTU
TCP/IP, LAN/WAN, XdSL or Serial networks
PSTN (Public Switched Telephone Network) or GPRS/3G modem connections
Radio modem connections
SCADA master station
Radio network 1
Radio network 2
Main functions
Main RTU system functions include:
Remote communications: b
Between remote RTU sites (coordination, synchronization) v
With the SCADA host system, controlling the central operator station v
(monitoring, detected alarm reports) and centralized databases (archiving of
detected alarms or events)
With the on-call staff (detected alarm indication) v
With the technical station (diagnostics, maintenance) v
Data acquisition, processing and memorization: b
Process data sampling using standard or dedicated sensors, validation v
Exchange of data with other devices within the station, including controllers and v
operator consoles
Use of digital or analog I/O, serial links, eldbuses and LANs v
Event detection, time and date stamping, prioritization and logging as required v
by the application
Other functions: b
IEC 1131-3 programmable control: forcing, access control, load sharing, v
servo control
Data logging v
Detected alarm and report notication by e-mail/SMS v
Web HMI: displaying the process, detected alarm handling, trend analysis, v
telecontrol
Example of an RTU system architecture
1
2
3
4
5
6
7
8
9
10
3/23
Introduction (continued) Modicon M340
automation platform
RTU communication protocols
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Introduction (continued)
Currently, people working in the industrial Telemetry sectors use standard protocols
for communication between control centers (SCADA) and RTU stations.
The following protocols are commonly used:
IEC 60870-5: IEC (International Electrotechnical Commission), in particular IEC b
60870-5-101/104 (commonly known as IEC 101 or 104)
DNP3: Distributed Network Protocol version 3 b
DNP3 is the predominant protocol in North America, Australia and South Africa
whereas, in certain European countries, the IEC protocol is required by the legislation.
IEC is also commonly used in the Middle East.
The geographical distribution of these protocols is as follows:
DNP3: North America, Australia, New Zealand, UK, etc, bAsia, South America
IEC 60870-5: Europe, Middle East, etc, bAsia, South America
These protocols offer similar functions.
They are both particularly suited to “transient communications” (modem, radio) and
data exchanges with limited bandwidth for the following reasons:
They transfer data between the SCADA system and the RTU devices b
They are essentially “event-triggeredprotocols (exchanges on changes of state, b
exchanges of time and date stamped events).
They offer the following transmission modes:
Interrogation via polling b
Data exchanges on changes of state b(RBE: Report By Exception)
Unsolicited messaging (a slave station can start an exchange of data with the b
master station).
Both protocols offer native data management and time and date stamped events:
Time synchronization between the master station and auxiliary stations via b
protocol functions
Time and date stamping of data and events b
Automatic transfer of time and date stamped events between the RTU stations b
and SCADA (control room).
1
2
3
4
5
6
7
8
9
10
3/24
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Le Introduction (continued)
The BMXNOR0200H communication module integrates RTU (Remote Terminal
Unit) functions and protocols into the Modicon M340 platform – for industrial
Telemetry applications and other widely distributed infrastructures.
The BMXNOR0200H module can be used to connect an RTU M340 PAC directly to
a Telemetry supervisor or to other RTU stations, via the standard DPN3 protocols
(subset level 3) or IEC 60870-5-101/104 with different connection methods: Ethernet
TCP/IP, LAN, WAN, serial link or modem connections (radio, PSTN, GSM, GPRS/3G,
ADSL).
The BMXNOR0200H module is designed to operate in a harsh environment
(conformal coating), in an extended temperature range (-25 to +70°C).
Functions
The BMXNOR0200H module offers the following functions:
Upstream RTU communication to the SCADA (server or slave mode) b
Downstream RTU communication to eld devices (master mode) b
RTU protocols: Time synchronization, exchanges of time and date stamped data b
via polling (on change of state and unsolicited), management of time and date
stamped events
Application Data Logging with time and date stamping in the module Flash b
memory card
Event notications via e-mail or SMS b
Embedded Web server for conguring the RTU protocol parameters, diagnostics b
and monitoring
Communications on Ethernet port: b
10BASE-T/100BASE-TX physical interface v
Modbus/TCP protocol (client and server) v
Integrated RTU protocols for Ethernet communications: DNP3 IP (client or server) v
and IEC 60870-5-104 (over IP) (client or server)
Connection of ADSL external modem on the Ethernet port, via the PPPoE v
(Point-to-Point Protocol over Ethernet) protocol
Advanced Ethernet functions: NTP client, FTP client or server, HTTP server, v
SOAP/XML server, SNMP agent, SMTP agent
Communications on serial port: b
Non-isolated RS232/RS485 point-to-point serial links v
Integrated RTU protocols for serial and modem communications: IEC 60870-5- v
101 (master or slave) and DNP3 serial (master or slave)
Connection of external modems (radio, PSTN, GSM, GPRS/3G) via the PPP v
(Point-to-Point Protocol) protocol
Description
The BMXNOR0200H module can be installed in either a standard or “ruggedized”
conguration, equipped with a standard BMXP34ppppp or “ruggedized”
BMXP34pppppH processor.
The front panel of the BMXNOR0200H module features:
Screw for locking the module in a slot in the rack.1
Display block with 8 LEDs, 4 relating to the serial and Ethernet 2
communication ports.
Dlot for a Flash memory card (SD card), with protective cover.3
RJ45 connector for the connection to the Ethernet network.4
RJ45 connector for connection of the serial link or an external modem.5
On the rear panel: 2 rotary switches for selecting the IP address assignment
method for the module.
5
3
1
2
4
Modicon M340
automation platform
RTU communication module
Introduction (continued),
functions,
description
1
2
3
4
5
6
7
8
9
10
3/25
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
References
Description Communication
port
Protocol Reference Weight
kg
RTU
communi-
cation module
(1)
Ethernet
10BASE-
100BASE-TX
Modbus b/TCP (client or
server), Transparent Ready
class C30
DNP3 IP (client or server) b
IEC 60870-5-104 (over IP) b
(client or server)
BMXNOR0200H
(2)
0.205
Serial, External
modems
Non-isolated RS232/ b
RS485 point-to-point serial
links
DNP3 serial (master or b
slave)
IEC 60870-5-101 (master b
or slave)
Spare parts
Description Usage Supplied with module Reference Weight
kg
128 MB Flash
memory card
supplied as
standard with
the module
Web pages,
Storage of
data logging
les (CSV)
BMXNOR0200H BMXRWS128MWF 0.002
(1) See ruggedized module specications, pages 6/2 and 6/8.
(2) The Web Designer software is supplied on CD-ROM with the module. This software can be
used to congure and download the embedded website and to congure advanced services:
data logging, sending detected alarm notications via SMS or e-mail, see page 3/16.
Modicon M340
automation platform
RTU communication module
References
BMXNOR0200H
1
2
3
4
5
6
7
8
9
10
3/26
Selection guide Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium hub and transceiver
Type of device Hub Transceiver
Interfaces Copper cable ports Number and type 4 x 10BASE-T ports 1 x 100BASE-TX port
Shielded connectors RJ45 RJ45
Medium Shielded twisted pair, category CAT 5E Shielded twisted pair, category CAT 5E
Maximum length of
pair
100 m 100 m
Fiber optic ports Number and type 1 x 100BASE-FX port
Connectors – SC
Medium – Multimode optical ber
Length of optical ber 50/125 µm 3000 m (1)
62.2/125 µm 3000 m (1)
Optical ber
attenuation analysis
50/125 µm ber 8 dB
62.2/125 µm ber 11 dB
Topology Number of hubs Cascaded 4 max.
In a ring
Redundancy P1 and P2 redundant power supplies P1 and P2 redundant power supplies
Power supply Voltage 24 V c (18 to 32), safety extra low voltage (SELV) 24 V c (18 to 32), safety extra low voltage (SELV)
Consumption 80 mA (130 max. at 24 V c) 160 mA (190 max. at 24 V c)
Removable terminal block 5-way 5-way
Operating temperature 0 to + 60°C 0 to + 60°C
Relative humidity 10 to 95% non condensing 10 to 95% non condensing
Degree of protection IP 30 IP 20
Dimensions W x H x D 40 x 125 x 80 mm 47 x 135 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide On symmetrical DIN rail, 35 mm wide
Weight 0.530 kg 0.230 kg
Conformity to standards cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2,
e, GL, C-Tick
cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2, e, GL, C-Tick
FM 3810, FM 3611 class 1 division 2
LED indicators Power supply, activity, link P1 and P2 power supplies, Ethernet link/port status
Alarm relay Power supply detected fault, Ethernet network detected fault or communication port detected
fault (volt-free contact 1 A max. at 24 V c)
Power supply detected fault, Ethernet network detected fault or communication port detected fault (volt-free contact 1 A max. at 24 V c)
Reference 499NEH10410 499NTR10100
Pages 3/42 3/42
(1) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 2000 m)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/27
Type of device Hub Transceiver
Interfaces Copper cable ports Number and type 4 x 10BASE-T ports 1 x 100BASE-TX port
Shielded connectors RJ45 RJ45
Medium Shielded twisted pair, category CAT 5E Shielded twisted pair, category CAT 5E
Maximum length of
pair
100 m 100 m
Fiber optic ports Number and type 1 x 100BASE-FX port
Connectors – SC
Medium – Multimode optical ber
Length of optical ber 50/125 µm 3000 m (1)
62.2/125 µm 3000 m (1)
Optical ber
attenuation analysis
50/125 µm ber 8 dB
62.2/125 µm ber 11 dB
Topology Number of hubs Cascaded 4 max.
In a ring
Redundancy P1 and P2 redundant power supplies P1 and P2 redundant power supplies
Power supply Voltage 24 V c (18 to 32), safety extra low voltage (SELV) 24 V c (18 to 32), safety extra low voltage (SELV)
Consumption 80 mA (130 max. at 24 V c) 160 mA (190 max. at 24 V c)
Removable terminal block 5-way 5-way
Operating temperature 0 to + 60°C 0 to + 60°C
Relative humidity 10 to 95% non condensing 10 to 95% non condensing
Degree of protection IP 30 IP 20
Dimensions W x H x D 40 x 125 x 80 mm 47 x 135 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide On symmetrical DIN rail, 35 mm wide
Weight 0.530 kg 0.230 kg
Conformity to standards cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2,
e, GL, C-Tick
cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2, e, GL, C-Tick
FM 3810, FM 3611 class 1 division 2
LED indicators Power supply, activity, link P1 and P2 power supplies, Ethernet link/port status
Alarm relay Power supply detected fault, Ethernet network detected fault or communication port detected
fault (volt-free contact 1 A max. at 24 V c)
Power supply detected fault, Ethernet network detected fault or communication port detected fault (volt-free contact 1 A max. at 24 V c)
Reference 499NEH10410 499NTR10100
Pages 3/42 3/42
(1) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 2000 m)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/28
Selection guide (continued) Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium unmanaged switches
Type of device Unmanaged switches, copper twisted pair Unmanaged switches, copper
twisted pair (continued)
Unmanaged switches, 4 and 5 ports, copper twisted pair and ber optic
Interfaces Copper cable ports Number and type 5 x 10BASE-T/100BASE-TX ports 8 x 10BASE-T/100BASE-TX ports 8 x 10BASE-T/100BASE-TX ports 3 x 10BASE-T/100BASE-TX ports 4 x 10BASE-T/100BASE-TX ports 5 x 10BASE-T/100BASE-TX ports
Shielded connectors M12 (type D) RJ45 RJ45 RJ45
Medium Shielded twisted pair, category CAT 5E Shielded twisted pair, category
CAT 5E
Shielded twisted pair, category CAT 5E
Maximum length of
pair
100 m 100 m 100 m
Fiber optic ports Number and type 1 x 100BASE-FX port
Connectors Duplex SC
Medium – Multimode optical ber
Length of optical ber 50/125 µm 5000 m (1)
62.2/125 µm 4000 m (1)
Optical ber
attenuation analysis
50/125 µm ber 8 dB
62.2/125 µm ber 11 dB
Ethernet services Storage and re-routing of received data,
auto MDI/MDX, automatic negotiation of
10/100 Mbps and duplex mode
(on each port)
Storage and re-routing of received
data, auto MDI/MDX, automatic
negotiation of 10/100 Mbps and
duplex mode (on each port),
automatic change of polarity
Storage and re-routing of received data, auto MDI/MDX,
automatic negotiation of 10/100 Mbps and duplex mode (on each port)
Topology Number of switches Cascaded Unlimited Unlimited Unlimited
Redundant in a ring
Redundancy P1 and P2 redundant power supplies
Power supply Voltage 24 V c (18 to 32), safety extra low voltage (SELV) 24 V c (9.6 to 32) SELV 24 V c (9.6 to 32 V) safety extra low voltage (SELV)
Consumption 100 mA max. 125 mA (290 mA max.) 4.1 W max. 2.2 W max. 3.9 W max. 2.2 W max.
Removable terminal block 5-way, M12 (type A, male) 5-way 3-way 3-way removable screw terminal block
Operating temperature 0 to + 60°C 0 to + 60°C 0 to + 60°C
Relative humidity 10 to 95% non condensing 95% max. without condensation 95% max. without condensation
Degree of protection IP 67 IP 20 IP 30 IP 30
Dimensions W x H x D 60 x 126 x 31 mm 47 x 135 x 111 mm 35 x 138 x 121 mm 25 x 114 x 79 mm
Mounting On symmetrical DIN rail, 35 mm wide On symmetrical DIN rail,
35 mm wide
On symmetrical DIN rail, 35 mm wide
Weight 0.210 kg 0.230 kg 0.246 kg 0.113 kg 0.120 kg 0.113 kg
Conformity to standards cUL 508 and CSA 22.2 No. 142 cUL 60950, UL 508 and CSA 22.2 No. 142,
UL 1604 and CSA 22.2 No. 213 class 1
division 2, e, GL, C-Tick
UL 508 and CSA 22.2 No.142
IEC/EN 61131-2,
IEC 60825-1 class 1, CISPR 11A
UL 508 and CSA 22.2 No. 142
IEC/EN 61131-2, IEC 60825-1 class 1, CISPR 11A
LED indicators Power supply, link status, data rate P1 and P2 power supplies, Ethernet link/port
status
Power supply, copper port activity,
10 or 100 Mbps data rate
Power supply, copper port activity, 10 or 100 Mbps data rate
Fiber port activity and status
Alarm relay Power supply detected fault, Ethernet
network detected fault or communication
port detected fault (volt-free contact
1 A max. at 24 V c)
– –
Reference TCSESU051F0 499NES18100 TCSESU083FN0 TCSESU033FN0 TCSESU043F1N0 TCSESU053FN0
Pages 3/43 3/43 3/44
(1) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 2000 m)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/29
Type of device Unmanaged switches, copper twisted pair Unmanaged switches, copper
twisted pair (continued)
Unmanaged switches, 4 and 5 ports, copper twisted pair and ber optic
Interfaces Copper cable ports Number and type 5 x 10BASE-T/100BASE-TX ports 8 x 10BASE-T/100BASE-TX ports 8 x 10BASE-T/100BASE-TX ports 3 x 10BASE-T/100BASE-TX ports 4 x 10BASE-T/100BASE-TX ports 5 x 10BASE-T/100BASE-TX ports
Shielded connectors M12 (type D) RJ45 RJ45 RJ45
Medium Shielded twisted pair, category CAT 5E Shielded twisted pair, category
CAT 5E
Shielded twisted pair, category CAT 5E
Maximum length of
pair
100 m 100 m 100 m
Fiber optic ports Number and type 1 x 100BASE-FX port
Connectors Duplex SC
Medium – Multimode optical ber
Length of optical ber 50/125 µm 5000 m (1)
62.2/125 µm 4000 m (1)
Optical ber
attenuation analysis
50/125 µm ber 8 dB
62.2/125 µm ber 11 dB
Ethernet services Storage and re-routing of received data,
auto MDI/MDX, automatic negotiation of
10/100 Mbps and duplex mode
(on each port)
Storage and re-routing of received
data, auto MDI/MDX, automatic
negotiation of 10/100 Mbps and
duplex mode (on each port),
automatic change of polarity
Storage and re-routing of received data, auto MDI/MDX,
automatic negotiation of 10/100 Mbps and duplex mode (on each port)
Topology Number of switches Cascaded Unlimited Unlimited Unlimited
Redundant in a ring
Redundancy P1 and P2 redundant power supplies
Power supply Voltage 24 V c (18 to 32), safety extra low voltage (SELV) 24 V c (9.6 to 32) SELV 24 V c (9.6 to 32 V) safety extra low voltage (SELV)
Consumption 100 mA max. 125 mA (290 mA max.) 4.1 W max. 2.2 W max. 3.9 W max. 2.2 W max.
Removable terminal block 5-way, M12 (type A, male) 5-way 3-way 3-way removable screw terminal block
Operating temperature 0 to + 60°C 0 to + 60°C 0 to + 60°C
Relative humidity 10 to 95% non condensing 95% max. without condensation 95% max. without condensation
Degree of protection IP 67 IP 20 IP 30 IP 30
Dimensions W x H x D 60 x 126 x 31 mm 47 x 135 x 111 mm 35 x 138 x 121 mm 25 x 114 x 79 mm
Mounting On symmetrical DIN rail, 35 mm wide On symmetrical DIN rail,
35 mm wide
On symmetrical DIN rail, 35 mm wide
Weight 0.210 kg 0.230 kg 0.246 kg 0.113 kg 0.120 kg 0.113 kg
Conformity to standards cUL 508 and CSA 22.2 No. 142 cUL 60950, UL 508 and CSA 22.2 No. 142,
UL 1604 and CSA 22.2 No. 213 class 1
division 2, e, GL, C-Tick
UL 508 and CSA 22.2 No.142
IEC/EN 61131-2,
IEC 60825-1 class 1, CISPR 11A
UL 508 and CSA 22.2 No. 142
IEC/EN 61131-2, IEC 60825-1 class 1, CISPR 11A
LED indicators Power supply, link status, data rate P1 and P2 power supplies, Ethernet link/port
status
Power supply, copper port activity,
10 or 100 Mbps data rate
Power supply, copper port activity, 10 or 100 Mbps data rate
Fiber port activity and status
Alarm relay Power supply detected fault, Ethernet
network detected fault or communication
port detected fault (volt-free contact
1 A max. at 24 V c)
– –
Reference TCSESU051F0 499NES18100 TCSESU083FN0 TCSESU033FN0 TCSESU043F1N0 TCSESU053FN0
Pages 3/43 3/43 3/44
(1) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 2000 m)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/30
Type of device Unmanaged switches, 5 ports, copper twisted pair and ber optic Managed switches, 4 ports, copper twisted pair and ber optic
Interfaces Copper cable ports Number and type 4 x 10BASE-T/
100BASE-TX ports
3 x 10BASE-T/
100BASE-TX ports
4 x 10BASE-T/
100BASE-TX ports
3 x 10BASE-T/
100BASE-TX ports
3 x
10/100BASE-TX ports
2 x
10/100BASE-TX ports
3 x
10/100BASE-TX ports
2 x
10/100BASE-TX ports
Shielded connectors RJ45 RJ45
Medium Shielded twisted pair, category CAT 5E Shielded twisted pair, category CAT 5E
Maximum length of
pair
100 m 100 m
Fiber optic ports Number and type 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports
Connectors SC Duplex SC
Medium Multimode optical ber Single mode optical ber Multimode optical ber Single mode optical ber
Length of optical
ber
50/125 µm 5000 m (1) 5000 m (1)
62.2/125 µm 4000 m (1) 4000 m (1)
9/125 µm ber 32,500 m (2) 32,500 m (2)
Optical ber
attenuation analysis
50/125 µm ber 8 dB 8 dB
62.2/125 µm ber 11 dB 11 dB
9/125 µm ber 16 dB 16 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol, conguration via Web access
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
Topology Number of switches Cascaded Unlimited Unlimited
Redundant in a ring 50 max.
Redundancy P1 and P2 redundant power supplies Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage 24 V c (18 to 32 V) safety extra low voltage (SELV) 9.6 to 60 V c/18 to 30 V a safety extra low voltage (SELV)
Consumption 200 mA max. 240 mA max. 200 mA max. 240 mA max. 6.5 W 7.3 W 6.5 W 7.3 W
Removable terminal block 5-way 6-way
Operating temperature - 40 to + 70°C 0 to + 60°C
Relative humidity 10 to 95% non condensing 10 to 90% non-condensing
Degree of protection IP 20 IP 20
Dimensions W x H x D 47 x 135 x 111 mm 47 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide On symmetrical DIN rail, 35 mm wide
Weight 0.330 kg 0.335 kg 0.330 kg 0.335 kg 0.400 kg
Conformity to standards cUL 60950, cUL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2,
e, GL, C-Tick
IEC 61131-2, IEC 61850-3, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 142 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick
LED indicators P1 and P2 power supplies, Ethernet link status, transmission activity Power supply status, alarm relay status, active redundancy, redundancy management, copper port status and copper port activity
Alarm relay Activity, power supply detected fault, Ethernet network detected fault or communication port
detected fault (volt-free contact 1 A max. at 24 V c)
Power supply detected fault, Ethernet network detected fault, communication port detected fault, redundancy detected fault (volt-free contact 1 A max. at 24 V c)
Reference 499NMS25101 499NMS25102 499NSS25101 499NSS25102 TCSESM043F1CU0 TCSESM043F2CU0 TCSESM043F1CS0 TCSESM043F2CS0
Pages 3/44 3/45
(1) Length dependent on the attenuation analysis and attenuation of the optical ber
(typical value: 2000 m)
(2) Length dependent on the attenuation analysis and attenuation of the optical ber
(typical value: 15,000 m)
(1) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 2000 m)
(2) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 15,000 m)
Selection guide (continued) Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium managed and unmanaged switches
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/31
Type of device Unmanaged switches, 5 ports, copper twisted pair and ber optic Managed switches, 4 ports, copper twisted pair and ber optic
Interfaces Copper cable ports Number and type 4 x 10BASE-T/
100BASE-TX ports
3 x 10BASE-T/
100BASE-TX ports
4 x 10BASE-T/
100BASE-TX ports
3 x 10BASE-T/
100BASE-TX ports
3 x
10/100BASE-TX ports
2 x
10/100BASE-TX ports
3 x
10/100BASE-TX ports
2 x
10/100BASE-TX ports
Shielded connectors RJ45 RJ45
Medium Shielded twisted pair, category CAT 5E Shielded twisted pair, category CAT 5E
Maximum length of
pair
100 m 100 m
Fiber optic ports Number and type 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports
Connectors SC Duplex SC
Medium Multimode optical ber Single mode optical ber Multimode optical ber Single mode optical ber
Length of optical
ber
50/125 µm 5000 m (1) 5000 m (1)
62.2/125 µm 4000 m (1) 4000 m (1)
9/125 µm ber 32,500 m (2) 32,500 m (2)
Optical ber
attenuation analysis
50/125 µm ber 8 dB 8 dB
62.2/125 µm ber 11 dB 11 dB
9/125 µm ber 16 dB 16 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol, conguration via Web access
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
Topology Number of switches Cascaded Unlimited Unlimited
Redundant in a ring 50 max.
Redundancy P1 and P2 redundant power supplies Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage 24 V c (18 to 32 V) safety extra low voltage (SELV) 9.6 to 60 V c/18 to 30 V a safety extra low voltage (SELV)
Consumption 200 mA max. 240 mA max. 200 mA max. 240 mA max. 6.5 W 7.3 W 6.5 W 7.3 W
Removable terminal block 5-way 6-way
Operating temperature - 40 to + 70°C 0 to + 60°C
Relative humidity 10 to 95% non condensing 10 to 90% non-condensing
Degree of protection IP 20 IP 20
Dimensions W x H x D 47 x 135 x 111 mm 47 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide On symmetrical DIN rail, 35 mm wide
Weight 0.330 kg 0.335 kg 0.330 kg 0.335 kg 0.400 kg
Conformity to standards cUL 60950, cUL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2,
e, GL, C-Tick
IEC 61131-2, IEC 61850-3, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 142 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick
LED indicators P1 and P2 power supplies, Ethernet link status, transmission activity Power supply status, alarm relay status, active redundancy, redundancy management, copper port status and copper port activity
Alarm relay Activity, power supply detected fault, Ethernet network detected fault or communication port
detected fault (volt-free contact 1 A max. at 24 V c)
Power supply detected fault, Ethernet network detected fault, communication port detected fault, redundancy detected fault (volt-free contact 1 A max. at 24 V c)
Reference 499NMS25101 499NMS25102 499NSS25101 499NSS25102 TCSESM043F1CU0 TCSESM043F2CU0 TCSESM043F1CS0 TCSESM043F2CS0
Pages 3/44 3/45
(1) Length dependent on the attenuation analysis and attenuation of the optical ber
(typical value: 2000 m)
(2) Length dependent on the attenuation analysis and attenuation of the optical ber
(typical value: 15,000 m)
(1) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 2000 m)
(2) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 15,000 m)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/32
Type of device Managed switches, 4 and 8 ports, copper twisted pair Managed switches, 8 ports, copper twisted pair and ber optic
Interfaces Copper cable ports Number and type 4 x 10/100BASE-TX ports 3 x 10/100BASE-TX ports 7 x
10/100BASE-TX ports
6 x
10/100BASE-TX ports
7 x
10/100BASE-TX ports
6 x
10/100BASE-T ports
Shielded connectors RJ45 RJ45
Medium Shielded twisted pair, category CAT 5E Shielded twisted pair, category CAT 5E
Maximum length of
pair
100 m 100 m
Fiber optic ports Number and type 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports
Connectors Duplex SC
Medium – Multimode optical ber Single mode optical ber
Length of optical ber 50/125 µm 5000 m (1)
62.2/125 µm 4000 m (1)
9/125 µm ber 32,500 m (2)
Attenuation analysis 50/125 µm ber 8 dB
62.2/125 µm ber 11 dB
9/125 µm ber 16 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol,
conguration via Web access,VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol),
priority port, data stream control, secure port
FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol, conguration via Web access
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
Topology Number of switches Cascaded Unlimited Unlimited
Redundant in a ring 50 max. 50 max.
Redundancy P1 and P2 redundant power supplies, redundant single ring, ring coupling Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage 9.6 to 60 V c/18 to 30 V a safety extra low voltage (SELV) 9.6 to 60 V c/18 to 30 V a, safety extra low voltage (SELV)
Consumption 5.3 W 6.5 W 7.3 W 6.5 W 7.3 W
Removable terminal block, 6-way 6-way
Operating temperature 0 to + 60°C 0 to + 60°C
Relative humidity 10 to 90% non-condensing 10 to 90% non-condensing
Degree of protection IP 20 IP 20
Dimensions W x H x D 47 x 131 x 111 mm 74 x 131 x 111 mm 75 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide On symmetrical DIN rail, 35 mm wide
Weight 0.400 kg 0.410 kg 0.410 kg
Conformity to standards IEC/EN 61131-2, IEC 61850-3, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL),
CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick
IEC/EN 61131-2, IEC 61850-3, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick
LED indicators Power supply status, alarm relay status,
active redundancy, redundancy management,
copper port status and copper port activity
Power supply status, alarm relay status,
active redundancy, redundancy management,
ber port status and ber port activity
Power supply status, alarm relay status, active redundancy, redundancy management, ber port status and ber port activity
Alarm relay Power supply detected fault, Ethernet network detected fault or communication port detected
fault (volt-free contact 1 A max. at 24 V c)
Power supply detected fault, Ethernet network detected fault or communication port detected fault (volt-free contact 1 A max. at 24 V c)
Reference TCSESM043F23F0 TCSESM083F23F0 TCSESM083F1CU0 TCSESM083F2CU0 TCSESM083F1CS0 TCSESM083F2CS0
Pages 3/45 3/46
(1) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 2000 m)
(2) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 15,000 m)
Selection guide (continued) Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium managed switches
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/33
Type of device Managed switches, 4 and 8 ports, copper twisted pair Managed switches, 8 ports, copper twisted pair and ber optic
Interfaces Copper cable ports Number and type 4 x 10/100BASE-TX ports 3 x 10/100BASE-TX ports 7 x
10/100BASE-TX ports
6 x
10/100BASE-TX ports
7 x
10/100BASE-TX ports
6 x
10/100BASE-T ports
Shielded connectors RJ45 RJ45
Medium Shielded twisted pair, category CAT 5E Shielded twisted pair, category CAT 5E
Maximum length of
pair
100 m 100 m
Fiber optic ports Number and type 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports
Connectors Duplex SC
Medium – Multimode optical ber Single mode optical ber
Length of optical ber 50/125 µm 5000 m (1)
62.2/125 µm 4000 m (1)
9/125 µm ber 32,500 m (2)
Attenuation analysis 50/125 µm ber 8 dB
62.2/125 µm ber 11 dB
9/125 µm ber 16 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol,
conguration via Web access,VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol),
priority port, data stream control, secure port
FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol, conguration via Web access
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
Topology Number of switches Cascaded Unlimited Unlimited
Redundant in a ring 50 max. 50 max.
Redundancy P1 and P2 redundant power supplies, redundant single ring, ring coupling Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage 9.6 to 60 V c/18 to 30 V a safety extra low voltage (SELV) 9.6 to 60 V c/18 to 30 V a, safety extra low voltage (SELV)
Consumption 5.3 W 6.5 W 7.3 W 6.5 W 7.3 W
Removable terminal block, 6-way 6-way
Operating temperature 0 to + 60°C 0 to + 60°C
Relative humidity 10 to 90% non-condensing 10 to 90% non-condensing
Degree of protection IP 20 IP 20
Dimensions W x H x D 47 x 131 x 111 mm 74 x 131 x 111 mm 75 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide On symmetrical DIN rail, 35 mm wide
Weight 0.400 kg 0.410 kg 0.410 kg
Conformity to standards IEC/EN 61131-2, IEC 61850-3, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL),
CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick
IEC/EN 61131-2, IEC 61850-3, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick
LED indicators Power supply status, alarm relay status,
active redundancy, redundancy management,
copper port status and copper port activity
Power supply status, alarm relay status,
active redundancy, redundancy management,
ber port status and ber port activity
Power supply status, alarm relay status, active redundancy, redundancy management, ber port status and ber port activity
Alarm relay Power supply detected fault, Ethernet network detected fault or communication port detected
fault (volt-free contact 1 A max. at 24 V c)
Power supply detected fault, Ethernet network detected fault or communication port detected fault (volt-free contact 1 A max. at 24 V c)
Reference TCSESM043F23F0 TCSESM083F23F0 TCSESM083F1CU0 TCSESM083F2CU0 TCSESM083F1CS0 TCSESM083F2CS0
Pages 3/45 3/46
(1) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 2000 m)
(2) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 15,000 m)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/34
Selection guide (continued) Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium managed switches
Type of device Managed switches, 8 extended ports, copper twisted pair and ber optic Managed switches, 16 and 24 ports, copper twisted pair and ber optic
Interfaces Copper cable ports Number and type 8 x 10/100BASE-TX ports 6 x 10/100BASE-TX ports 6 10/100BASE-T ports 16 x 10/100BASE-TX ports 14 x 10/100BASE-TX ports 22 x 10/100BASE-TX ports
Shielded connectors RJ45 RJ45
Medium Shielded twisted pair, category CAT 5E Shielded twisted pair, category CAT 5E
Maximum length of
pair
100 m 100 m
Fiber optic ports Number and type 2 x 100BASE-FX ports 2 x 100BASE-FX ports
Connectors Duplex SC Duplex SC
Medium – Multimode optical ber Single mode optical ber Multimode optical ber
Length of optical ber 50/125 µm 5000 m (1) 5000 m (1)
62.2/125 µm 4000 m (1) 4000 m (1)
9/125 µm ber 32,500 m (2) –––
Attenuation analysis 50/125 µm ber 8 dB 8 dB
62.2/125 µm ber 11 dB 11 dB
9/125 µm ber 16 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol,
conguration via Web access,VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol),
priority port, data stream control, secure port
FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol, conguration via Web access
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
Topology Number of switches Cascaded Unlimited Unlimited
Redundant in a ring 50 max. 50 max.
Redundancy Redundant power supplies, redundant single ring, ring coupling,
rings supporting MRP, Fast Hiper Ring and RSTP
Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage 18 to 60 V c9.6 to 60 V c/18 to 30 V a safety extra low voltage (SELV)
Consumption 10 W 12 W 9.4 W 11.8 W 15.5 W
Removable terminal block 2 terminal blocks, 2-way 6-way
Operating temperature 0 to + 60°C 0 to + 60°C
Relative humidity 10 to 90% non-condensing 10 to 90% non-condensing
Degree of protection IP 30 IP 20
Dimensions W x H x D 120 x 137 x 115 mm 111 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide On symmetrical DIN rail, 35 mm wide
Weight 1 kg 0.600 kg 0.650 kg
Conformity to standards IEC/EN 61131-2, IEC 61850-3, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL),
CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick, LR, BV
cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2
LED indicators Power supply status, alarm relay status, active redundancy, redundancy management,
copper port status and copper port activity
Redundant power supplies, single ring Redundant power supplies, single ring, double ring
Alarm relay Power supply detected fault, Ethernet network detected fault or communication port detected
fault (volt-free contact 1 A max. at 24 V c, 2-way)
Power supply detected fault, Ethernet network detected fault or communication port detected fault (volt-free contact 1 A max. at 24 V c)
Reference TCSESM083F23F1 TCSESM063F2CU1 TCSESM063F2CS1 TCSESM163F23F0 TCSESM163F2CU0 TCSESM243F2CU0
Pages 3/46 3/47
1) Length dependent on the attenuation analysis and attenuation of the optical ber
(typical value: 2000 m)
(2) Length dependent on the attenuation analysis and attenuation of the optical ber
(typical value: 15,000 m)
(1) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 2000 m)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/35
Type of device Managed switches, 8 extended ports, copper twisted pair and ber optic Managed switches, 16 and 24 ports, copper twisted pair and ber optic
Interfaces Copper cable ports Number and type 8 x 10/100BASE-TX ports 6 x 10/100BASE-TX ports 6 10/100BASE-T ports 16 x 10/100BASE-TX ports 14 x 10/100BASE-TX ports 22 x 10/100BASE-TX ports
Shielded connectors RJ45 RJ45
Medium Shielded twisted pair, category CAT 5E Shielded twisted pair, category CAT 5E
Maximum length of
pair
100 m 100 m
Fiber optic ports Number and type 2 x 100BASE-FX ports 2 x 100BASE-FX ports
Connectors Duplex SC Duplex SC
Medium – Multimode optical ber Single mode optical ber Multimode optical ber
Length of optical ber 50/125 µm 5000 m (1) 5000 m (1)
62.2/125 µm 4000 m (1) 4000 m (1)
9/125 µm ber 32,500 m (2) –––
Attenuation analysis 50/125 µm ber 8 dB 8 dB
62.2/125 µm ber 11 dB 11 dB
9/125 µm ber 16 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol,
conguration via Web access,VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol),
priority port, data stream control, secure port
FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol, conguration via Web access
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port
Topology Number of switches Cascaded Unlimited Unlimited
Redundant in a ring 50 max. 50 max.
Redundancy Redundant power supplies, redundant single ring, ring coupling,
rings supporting MRP, Fast Hiper Ring and RSTP
Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage 18 to 60 V c9.6 to 60 V c/18 to 30 V a safety extra low voltage (SELV)
Consumption 10 W 12 W 9.4 W 11.8 W 15.5 W
Removable terminal block 2 terminal blocks, 2-way 6-way
Operating temperature 0 to + 60°C 0 to + 60°C
Relative humidity 10 to 90% non-condensing 10 to 90% non-condensing
Degree of protection IP 30 IP 20
Dimensions W x H x D 120 x 137 x 115 mm 111 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide On symmetrical DIN rail, 35 mm wide
Weight 1 kg 0.600 kg 0.650 kg
Conformity to standards IEC/EN 61131-2, IEC 61850-3, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL),
CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick, LR, BV
cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2
LED indicators Power supply status, alarm relay status, active redundancy, redundancy management,
copper port status and copper port activity
Redundant power supplies, single ring Redundant power supplies, single ring, double ring
Alarm relay Power supply detected fault, Ethernet network detected fault or communication port detected
fault (volt-free contact 1 A max. at 24 V c, 2-way)
Power supply detected fault, Ethernet network detected fault or communication port detected fault (volt-free contact 1 A max. at 24 V c)
Reference TCSESM083F23F1 TCSESM063F2CU1 TCSESM063F2CS1 TCSESM163F23F0 TCSESM163F2CU0 TCSESM243F2CU0
Pages 3/46 3/47
1) Length dependent on the attenuation analysis and attenuation of the optical ber
(typical value: 2000 m)
(2) Length dependent on the attenuation analysis and attenuation of the optical ber
(typical value: 15,000 m)
(1) Length dependent on the attenuation analysis and attenuation of the optical ber (typical value: 2000 m)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/36
Selection guide (continued) Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium managed switches
Type of device Managed switches, 8 ports and 2 Gigabit ports, copper twisted pair and ber optic Managed switches, 8 ports and 2 Gigabit ports, copper twisted pair and ber optic
Interfaces Copper cable ports Number and type 8 x 10/100BASE-TX ports 8 x 10/100BASE-TX ports and
2 x 10/100/1000BASE-TX (Gigabit) ports
Shielded connectors RJ45 RJ45
Medium Shielded twisted pair, category CAT 5E Shielded twisted pair, category CAT 5E
Maximum length of
pair
100 m 100 m
Fiber optic
Gigabit ports
(with SFP ber optic
module to be mounted
on SFP connector)
Number and type 2 x 1000BASE-SX ports (1) 2 x 1000BASE-LH ports (2) 2 x 1000BASE-LX ports (3)
Connectors LC LC
Medium Multimode optical ber Single mode optical ber Single mode and multimode
optical ber
Length of optical ber 50/125 µm 550 m 550 m
62.2/125 µm 275 m 550 m
9/125 µm ber 8 - 72,000 m 20,000 m
Attenuation analysis 50/125 µm ber 7.5 dB 11 dB
62.2/125 µm ber 7.5 dB 11 dB
9/125 µm ber 6 - 22 dB 11 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol,
conguration via Web access,VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol),
priority port, data stream control, secure port
FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol, conguration via Web access,VLAN, IGMP Snooping, RSTP (Rapid
Scanning Tree Protocol), priority port, data stream control, secure port
Topology Number of switches Cascaded Unlimited Unlimited
Redundant in a ring 50 max. 50 max.
Redundancy Redundant power supplies, redundant single ring, ring coupling Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage 9.6 to 60 V c/18 to 30 V a safety extra low voltage (SELV) 9.6 to 60 V c/18 to 30 V a safety extra low voltage (SELV)
Consumption 8.9 W + 1 W per SFP ber optic module 8.3 W
Removable terminal block 6-way 6-way
Operating temperature 0 to + 60°C 0 to + 60°C
Relative humidity 10 to 90% non-condensing 10 to 90% non-condensing
Degree of protection IP 20 IP 20
Dimensions W x H x D 111 x 131 x 111 mm 111 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide On symmetrical DIN rail, 35 mm wide
Weight 0.410 kg 0.410 kg
Conformity to standards cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2,
e, GL
cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2, e, GL
LED indicators Power supply status, alarm relay status, active redundancy, redundancy management,
ber port status and ber port activity
Power supply status, alarm relay status, active redundancy, redundancy management, ber port status and ber port activity
Alarm relay Power supply detected fault, Ethernet network detected fault or communication port detected
fault (volt-free contact 1 A max. at 24 V c)
Power supply detected fault, Ethernet network detected fault or communication port detected fault (volt-free contact 1 A max. at 24 V c)
Reference TCSESM103F2LG0 TCSESM103F23G0
Pages 3/47 3/47
(1) With TCSEAAF1LFU00 ber optic module to be ordered separately (see page 3/41)
(2) With TCSEAAF1LFH00 ber optic module to be ordered separately (see page 3/41)
(3) With TCSEAAF1LFS00 ber optic module to be ordered separately (see page 3/41)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/37
Type of device Managed switches, 8 ports and 2 Gigabit ports, copper twisted pair and ber optic Managed switches, 8 ports and 2 Gigabit ports, copper twisted pair and ber optic
Interfaces Copper cable ports Number and type 8 x 10/100BASE-TX ports 8 x 10/100BASE-TX ports and
2 x 10/100/1000BASE-TX (Gigabit) ports
Shielded connectors RJ45 RJ45
Medium Shielded twisted pair, category CAT 5E Shielded twisted pair, category CAT 5E
Maximum length of
pair
100 m 100 m
Fiber optic
Gigabit ports
(with SFP ber optic
module to be mounted
on SFP connector)
Number and type 2 x 1000BASE-SX ports (1) 2 x 1000BASE-LH ports (2) 2 x 1000BASE-LX ports (3)
Connectors LC LC
Medium Multimode optical ber Single mode optical ber Single mode and multimode
optical ber
Length of optical ber 50/125 µm 550 m 550 m
62.2/125 µm 275 m 550 m
9/125 µm ber 8 - 72,000 m 20,000 m
Attenuation analysis 50/125 µm ber 7.5 dB 11 dB
62.2/125 µm ber 7.5 dB 11 dB
9/125 µm ber 6 - 22 dB 11 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol,
conguration via Web access,VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol),
priority port, data stream control, secure port
FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol, conguration via Web access,VLAN, IGMP Snooping, RSTP (Rapid
Scanning Tree Protocol), priority port, data stream control, secure port
Topology Number of switches Cascaded Unlimited Unlimited
Redundant in a ring 50 max. 50 max.
Redundancy Redundant power supplies, redundant single ring, ring coupling Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage 9.6 to 60 V c/18 to 30 V a safety extra low voltage (SELV) 9.6 to 60 V c/18 to 30 V a safety extra low voltage (SELV)
Consumption 8.9 W + 1 W per SFP ber optic module 8.3 W
Removable terminal block 6-way 6-way
Operating temperature 0 to + 60°C 0 to + 60°C
Relative humidity 10 to 90% non-condensing 10 to 90% non-condensing
Degree of protection IP 20 IP 20
Dimensions W x H x D 111 x 131 x 111 mm 111 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide On symmetrical DIN rail, 35 mm wide
Weight 0.410 kg 0.410 kg
Conformity to standards cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2,
e, GL
cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2, e, GL
LED indicators Power supply status, alarm relay status, active redundancy, redundancy management,
ber port status and ber port activity
Power supply status, alarm relay status, active redundancy, redundancy management, ber port status and ber port activity
Alarm relay Power supply detected fault, Ethernet network detected fault or communication port detected
fault (volt-free contact 1 A max. at 24 V c)
Power supply detected fault, Ethernet network detected fault or communication port detected fault (volt-free contact 1 A max. at 24 V c)
Reference TCSESM103F2LG0 TCSESM103F23G0
Pages 3/47 3/47
(1) With TCSEAAF1LFU00 ber optic module to be ordered separately (see page 3/41)
(2) With TCSEAAF1LFH00 ber optic module to be ordered separately (see page 3/41)
(3) With TCSEAAF1LFS00 ber optic module to be ordered separately (see page 3/41)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/38
Wi-Fi network:
page 3/48
Cabling systems Modicon M340
automation platform
Cabling systems for Ethernet networks
Infrastructure
Introduction
Schneider Electric offers copper and ber optic cables for connecting IP 20 and IP 67
Ethernet devices.
Examples
Mixed IP 20 and IP 67 wiring (copper)
2, 4
2, 4
2, 4
1, 3
1, 3
1, 3
1, 3
1, 3
8
8
1, 3
Key:
1, 3: Straight-through copper cables
2, 4: Crossover copper cables
8: Cables with IP 67 connector (see pages 3/40 and 3/41)
1
2
3
4
5
6
7
8
9
10
3/39
Wi-Fi network:
page 3/48
Cabling systems (continued) Modicon M340
automation platform
Cabling systems for Ethernet networks
Infrastructure
Examples (continued)
Mixed copper and ber optic wiring
Key:
1, 3: Straight-through copper cables
2, 4: Crossover copper cables
5, 6, 7: Fiber optic cables
8: Cables with IP 67 connector (see pages 3/40 and 3/41)
Firewall
5, 6, 7
2, 4
8
Magelis XBT HMI
Magelis XBT HMI
Advantys STB
Advantys STBTwido PLC
Altivar 71
drive
Altivar 71
drive
Ositrack
Modbus
Modicon M340 PAC
Modicon Quantum
PAC
Modicon Premium PAC
1, 3 1, 3
1, 3
1, 3
1, 3
1, 3
1, 3
1, 3
1, 3
1, 3
1, 31, 3
1, 3
1, 3
1, 3
1, 3
2, 4
2, 4
2, 4 2, 4
2, 4 2, 4
2, 4 2, 4
2, 4
Preventa safety PLC
Internet
MES Client
Router
FactoryCast
gateway
Managed
switch
Hub or
unmanaged switch
Fiber optic link
Copper link
Copper link
Server
1
2
3
4
5
6
7
8
9
10
3/40
Wi-Fi network:
page 3/48
References Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium connection components
Shielded copper connection cables
ConneXium shielded connection cables are available in two versions to meet
current standards and approvals:
EIA/TIA 568 shielded twisted pair cables for b e market
These cables conform to:
EIA/TIA-568 standard, category CAT 5E v
IEC 11801/EN 50173-1 standard, class D v
Their re resistance conforms to:
NF C32-070 standard, class C2 v
IEC 322/1 standards v
Low Smoke Zero Halogen (LSZH) v
EIA/TIA 568 shielded twisted pair bcables for UL market
These cables are:
CEC type FT-1 v
NEC type CM v
EIA/TIA 568 shielded twisted pair cables for e market
Description Preformed with
connectors at
both ends
Marked Length Reference Weight
kg
Straight-through
copper cables
2 RJ45 connectors
For connection to
terminal devices (DTE)
12 m 490NTW00002
5 m 490NTW00005
12 m 490NTW00012
40 m 490NTW00040
80 m 490NTW00080
Crossover
copper cables
2 RJ45 connectors
For connections
between hubs,
switches and
transceivers
25 m 490NTC00005
15 m 490NTC00015
40 m 490NTC00040
80 m 490NTC00080
Shielded twisted pair cables for UL market
Description Preformed with
connectors at
both ends
Marked Length Reference Weight
kg
Straight-through
copper cables
2 RJ45 connectors
For connection to
terminal devices (DTE)
32 m 490NTW00002U
5 m 490NTW00005U
12 m 490NTW00012U
40 m 490NTW00040U
80 m 490NTW00080U
Crossover
copper cables
2 RJ45 connectors
For connections
between hubs,
switches and
transceivers
45 m 490NTC00005U
40 m 490NTC00040U
80 m 490NTC00080U
“Do it Yourself” copper cable and connectors
The ConneXium “Do it Yourself” offer consists of 2 references for "eld-installable"
connectors (M12 and RJ45) and one reference for spooled cable measuring 300 m,
for wiring Ethernet 10/100 Mbps networks.
The maximum length of the cables created using these components is 80 m.
They are quick to assemble using only a knife and simple wire cutters (no special
tool is required).
Description Specications Length Reference Weight
kg
Ethernet copper cable
2 shielded twisted pairs
24 AWG
Conforms to the
standards and approval
listed above
300 m TCSECN300R2
RJ45 connector Conforms to
EIA/TIA-568-D
TCSEK3MDS
M12 connector Conforms to
IEC 60176-2-101
TCSEK1MDRS
490 NTp 000 pp
1
2
3
4
5
6
7
8
9
10
3/41
Wi-Fi network:
page 3/48
References (continued) Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium connection components
Glass ber optic cables
Glass ber optic cables are used for connections:
To terminal devices (DTE) b
Between hubs, transceivers and switches b
Description Preformed with
connectors at both ends
Marked Length Reference Weight
kg
Glass ber optic
cables
1 SC connector
1 MT-RJ connector
55 m 490NOC00005
1 ST (BFOC) connector
1 MT-RJ connector
65 m 490NOT00005
2 MT-RJ connectors 73 m 490NOR00003
5 m 490NOR00005
Separate parts for TCSESMswitches
Description Optical ber Type Reference Weight
kg
Fiber optic
modules for
Gigabit ports with
LC connector
(1)
Multimode 50/125 µm or
62.5/125 µm
1000BASE-SX TCSEAAF1LFU00 0.040
Single mode 9/125 µm 1000BASE-LH TCSEAAF1LFH00 0.040
Multimode 50/125 µm or
62.5/125 µm
Single mode 62.5/125 µm
1000BASE-LX TCSEAAF1LFS00 0.040
Conguration
backup key
Via the USB port on the front of the switch,
used to:
Save and retrieve the switch -
conguration
Update the internal software -
TCSEAM0100
(1) Dimensions: W x H x D = 20 x 18 x 50 mm
Connection components for IP 67 switch
Description Preformed with
connectors at both ends
Marked Length Reference Weight
kg
Straight-through
copper cables
1 IP 67 4-way M12
connector and 1 RJ45
connector
81 m TCSECL1M3M1S2
3 m TCSECL1M3M3S2
10 m TCSECL1M3M10S2
25 m TCSECL1M3M25S2
40 m TCSECL1M3M40S2
2 IP 67 4-way M12
connectors
1 m TCSECL1M1M1S2
3 m TCSECL1M1M3S2
10 m TCSECL1M1M10S2
25 m TCSECL1M1M25S2
40 m TCSECL1M1M40S2
Power supply
cables
2 female M12
straight connectors
2 m XZCP1164L2
5 m XZCP1164L5
2 female M12
angled connectors
2.5 m XZCP1264L2
5 m XZCP1264L5
Power supply
cables
2 female M12
straight connectors
XZCC12FDM50B
2 female M12
angled connectors
XZCC12FCM50B
M12/RJ45
adaptor
IP 67 female 4-way M12
connector and female
RJ45 connector
TCSEAAF11F13F00
490NOC00005
490NOR00005
490NOT00005
TCSEAAF1LFp00
1
2
3
4
5
6
7
8
9
10
3/42
Wi-Fi network:
page 3/48
Introduction,
references
Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium hub and transceiver
ConneXium hub
Introduction
Hubs (concentrators) are used for transmitting signals between several media (ports).
Hubs are “plug and play” devices that do not require conguration by the user.
The use of hubs makes it possible to create the following topologies:
Star topology b
Tree topology b
DTE DTE
DTE DTE
DTE DTE
Star topology Tree topology
Hub
Hub
HubHub
Reference
Description Interfaces Reference Weight
kg
ConneXium hub 4 x 10BASE-T ports
(copper cable), RJ45 shielded
connectors
499NEH10410 0.530
ConneXium transceiver
Introduction
ConneXium transceivers are used to:
Create ber optic linear bus topologies, for devices with a twisted pair cable b
Ethernet connection
Interface devices with a twisted pair cable Ethernet connection with a ber b
optic cable
Transceivers are “plug and play” devices that do not require conguration by the user.
ConneXium transceivers provide ber optic connections for transmission in areas
subject to interference (high levels of electromagnetic interference) and for long
distance communications.
DTEDTE
DTE
Linear topology on optical ber
Reference
Description Interfaces Reference Weight
kg
ConneXium transceiver 1 x 10BASE-T port b
(copper cable), RJ45 shielded
connector
1 x 100BASE-FX port b
(multimode optical ber),
SC connector
499NTR10100 0.230
499NEH10410
499NTR10100
1
2
3
4
5
6
7
8
9
10
3/43
Wi-Fi network:
page 3/48
Introduction,
references
Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium unmanaged switches
ConneXium unmanaged switches, twisted pair
Introduction
Switches are used to increase the limits of architectures based on hubs or
transceivers, by separating collision domains.
Higher layer communication is provided between the ports, and collisions at link
layer are not propagated (ltering).
They therefore improve performance by better allocation of the bandwidth due to
the reduction of collisions and the network load.
Certain ConneXium switch models also enable redundant architectures to be
created on twisted pair copper ring or optical ber.
Unmanaged switches are “plug & play” devices that do not require conguration by
the user. Certain models can also be managed remotely via SNMP or HTTP
protocols for monitoring and diagnostic purposes.
DTE
DTEDTE
DTE DTE
DTE DTE
DTE DTE
DTE
DTEDTE
DTE DTE
DTE
DTEDTE
DTE DTE
DTE DTE
100 Mbps
ber-optic ring
Collision
domain 1
Collision
domain 2
Collision
domain 3
Reference
Description Interfaces Reference Weight
kg
ConneXium unmanaged
switches
5 x 10BASE-T/100BASE-TX ports
(copper cable), shielded M12 type
D connectors, IP67
TCSESU051F0 0.210
8 x 10BASE-T/100BASE-TX ports
(copper cable), RJ45 shielded
connectors, IP20
499NES18100 0.230
8 x 10BASE-T/100BASE-TX ports
(copper cable), RJ45 shielded
connectors, IP30
TCSESU083FN0 0.246
Description Preformed
with connectors
at both ends
Length Reference Weight
kg
IP67 power supply cables
(for ConneXium switch
TCSESU051F0)
Female M12
straight connector
2 m XZC P1164L2
5 m XZC P1164L5
Female M12
angled connector
2 m XZC P1264L2
5 m XZC P1264L5
IP67 power supply
connectors
(for ConneXium switch
TCSESU051F0)
Female M12
straight connector
XZC C12 FDM 50B
Female M12
angled connector
XZC C12 FCM 50B
499NES18100
TCSESU051F0
1
2
3
4
5
6
7
8
9
10
3/44
Wi-Fi network:
page 3/48
References (continued) Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium unmanaged switches
ConneXium unmanaged switches, 3, 4 and 5 ports,
twisted pair and ber optic
References
Description Interfaces Reference Weight
kg
ConneXium unmanaged
switches
3 x 10BASE-T/100BASE-
TX ports (copper cable), RJ45
shielded connectors
TCSESU033FN0 0.113
4 x 10BASE-T/100BASE-TX b
ports (copper cable),
RJ45 shielded connectors
1 x 100BASE-FX port b
(multimode optical ber),
duplex SC connector
TCSESU043F1N0 0.120
5 x 10BASE-T/100BASE-
TX ports (copper cable), RJ45
shielded connectors
TCSESU053FN0 0.113
ConneXium unmanaged switches, 5 ports, twisted pair
and ber optic
Reference
Description Interfaces Reference Weight
kg
ConneXium unmanaged
switches
4 x 10BASE-T/100BASE-TX b
ports (copper cable),
RJ45 shielded connectors
1 x 100BASE-FX port b
(multimode optical ber),
duplex SC connector
499NMS25101 0.330
3 x 10BASE-T/100BASE-TX b
ports (copper cable),
RJ45 shielded connectors
2 x 100BASE-FX ports b
(multimode optical ber),
duplex SC connector
499NMS25102 0.335
4 x 10BASE-T/100BASE-TX b
ports (copper cable),
RJ45 shielded connectors
1 x 100BASE-FX port (single b
mode optical ber), duplex
SC connector
499NSS25101 0.330
3 x 10BASE-T/100BASE-TX b
ports (copper cable),
RJ45 shielded connectors
2 x 100BASE-FX ports (single b
mode optical ber), duplex
SC connector
499NSS25102 0.335
TCSESU053FN0
499NMS25101
499NSS25102
1
2
3
4
5
6
7
8
9
10
3/45
Wi-Fi network:
page 3/48
References (continued) Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium managed switches
ConneXium managed switches, 4 ports, twisted pair
and ber optic
References
Description Interfaces Reference Weight
kg
ConneXium managed
switches
3 x 10BASE-T/100BASE-TX b
ports (copper cable),
RJ45 shielded connectors
1 x 100BASE-FX port b
(multimode optical ber),
duplex SC connector
TCSESM043F1CU0 0.400
2 x 10BASE-T/100BASE-TX b
ports (copper cable),
RJ45 shielded connectors
2 x 100BASE-FX ports b
(multimode optical ber),
duplex SC connector
TCSESM043F2CU0 0.400
3 x 10BASE-T/100BASE-TX b
ports (copper cable),
RJ45 shielded connectors
1 x 100BASE-FX port (single b
mode optical ber), duplex
SC connector
TCSESU043F1CS0 0.400
2 x 10BASE-T/100BASE-TX b
ports (copper cable),
RJ45 shielded connectors
2 x 100BASE-FX ports b
(single mode optical ber),
duplex SC connector
TCSESU043F2CS0 0.400
ConneXium managed switches, 4 and 8 ports, twisted pair
References
Description Interfaces Reference Weight
kg
ConneXium managed
switches
4 x 10/100BASE-TX ports
(copper cable), RJ45 shielded
connectors
TCSESM043F23F0 0.400
8 x 10/100BASE-TX ports
(copper cable), RJ45 shielded
connectors
TCSESM083F23F0 0.410
TCSESM043F1CU0
TCSESM043F2CS0
TCSESM083F23F0
1
2
3
4
5
6
7
8
9
10
3/46
Wi-Fi network:
page 3/48
References (continued) Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium managed switches
ConneXium managed switches, 8 ports, twisted pair
and ber optic
References
Description Interfaces Reference Weight
kg
ConneXium managed
switches
7 x 10/100BASE-TX ports b
(copper cable), RJ45 shielded
connectors
1 x 100BASE-FX port b
(multimode optical ber),
duplex SC connector
TCSESM083F1CU0 0.410
6 x 10/100BASE-TX ports b
(copper cable), RJ45 shielded
connectors
2 x 100BASE-FX ports b
(multimode optical ber),
duplex SC connector
TCSESM083F2CU0 0.410
7 x 10/100BASE-TX ports b
(copper cable), RJ45 shielded
connectors
1 x 100BASE-FX port (single b
mode optical ber), duplex
SC connector
TCSESM083F1CS0 0.410
6 x 10/100BASE-TX ports b
(copper cable), RJ45 shielded
connectors
2 x 100BASE-FX ports (single b
mode optical ber), duplex
SC connector
TCSESM083F2CS0 0.410
ConneXium managed switches, 8 extended ports,
twisted pair and ber optic
References
Description Interfaces Reference Weight
kg
ConneXium managed
switches
8 x 10/100BASE-TX ports
(copper cable), RJ45 shielded
connectors, IP30
TCSESM083F23F1 1.000
6 x 10/100BASE-TX ports b
(copper cable), RJ45 shielded
connectors, IP30
2 x 100BASE-FX ports b
(multimode optical ber),
duplex SC connector
TCSESM063F2CU1 1.000
6 x 10/100BASE-TX ports b
(copper cable), RJ45 shielded
connectors, IP30
2 x 100BASE-FX ports (single b
mode optical ber), duplex
SC connector
TCSESM063F2CS1 1.000
TCSESM083F1CU0
TCSESM083F2CS0
TCSESM063F2CS1
1
2
3
4
5
6
7
8
9
10
3/47
Wi-Fi network:
page 3/48
References (continued) Modicon M340
automation platform
Cabling systems for Ethernet networks
ConneXium managed switches
ConneXium managed switches, 16 and 24 ports,
twisted pair and ber optic
References
Description Interfaces Reference Weight
kg
ConneXium managed
switches
16 x 10/100BASE-TX ports
(copper cable), RJ45 shielded
connectors
TCSESM163F23F0 0.600
14 x 10/100BASE-TX ports b
(copper cable), RJ45 shielded
connectors
2 x 100BASE-FX ports b
(multimode optical ber), duplex
SC connector
TCSESM163F2CU0 0.600
22 x 10/100BASE-TX ports b
(copper cable), RJ45 shielded
connectors
2 x 100BASE-FX ports b
(multimode optical ber), duplex
SC connector
TCSESM243F2CU0 0.650
ConneXium managed switches, 8 ports and 2 Gigabit ports,
twisted pair and ber optic
References
Description Interfaces Reference Weight
kg
ConneXium managed
switches
8 x 10/100BASE-TX ports b
(copper cable), RJ45 shielded
connectors
2 x 1000BASE-SX ports b
(multimode optical ber) (1), or
2 x 1000BASE-LH ports b
(single mode optical ber) (2), or
2 x 1000BASE-LX ports b
(single mode and multimode
optical ber) (3)
TCSESM103F2LG0 0.410
8 x 10/100BASE-TX ports b
(copper cable), RJ45 shielded
connectors
2 x 10/100/1000BASE-TX b
(Gigabit) ports (copper cable),
RJ45 shielded connectors
TCSESM103F23G0 0.410
(1) With TCSEAAF1LFU000 ber optic module to be ordered separately (see page 3/41)
(2) With TCSEAAF1LFH000 ber optic module to be ordered separately (see page 3/41)
(3) With TCSEAAF1LFS000 ber optic module to be ordered separately (see page 3/41)
TCSESM163F23F0
TCSESM243F2CU0
TCSESM103F2LG0
TCSESM103F23G0
1
2
3
4
5
6
7
8
9
10
3/48
Selection guide Modicon M340
automation platform
Cabling systems for Wi-Fi networks
Wi-Fi access points and clients
Type of device Wi-Fi 802.11g Access Point Wi-Fi 802.11g Access Point FCC Wi-Fi 802.11g Access Point IP 67 Wi-Fi 802.11g Client
Description Dual band industrial wireless LAN
Access Point/Client with two independent
radio modules based on IEEE 802.11a/b/g/h/i.
Dual band industrial wireless LAN
Access Point/Client with two independent
radio modules, based on IEEE 802.11a/b/g/h/i.
With FCC-approval for USA and Canada.
Dual band industrial wireless LAN Access Point/Client with two independent
radio modules based on IEEE 802.11a/b/g/h/i for installation in harsh
environment, IP 67 rated.
Single band industrial wireless LAN Client with one radio module based on IEEE
802.11a/b/g/h/i.
Type Access Point and Client Access Point and Client Client only
Wireless standard IEEE 802.11a/b/g/h/i IEEE 802.11a/b/g/h/i
Operating frequencies 2.4 GHz and 5 GHz 2.4 GHz and 5 GHz
Degree of protection IP 40 IP 67 IP 40
Regional approvals – FCC
Mounting DIN rail Wall/mast DIN rail
Number of radios 2 2 1
Nominal data rate 54 Mbps 54 Mbps
Antenna connections 4 x RP-SMA 4 x N-type 4 x RP-SMA
Ethernet connections 2 x 10/100BASE-TX 1 x 10/100BASE-TX
Wireless connections 2 x WLAN interfaces, 8 SSIDs per interface (1) 2 x WLAN interfaces, 8 SSIDs per interface (1) 1 x WLAN interface
Range Up to 20 km with external antenna (depending on type of antenna, frequency range and data
rate)
Up to 20 km with external antenna (depending on type of antenna, frequency range and data rate)
Dimensions 80 x 100 x 135 mm 261 x 189 x 55 mm 80 x 100 x 135 mm
Operating temperature -30°C to +50°C -30°C to +55°C
Storage temperature -40°C to +70°C -40°C to +70°C
Humidity Max. 95% (non-condensing) Max. 95% (non-condensing)
Power supplies 2 x 24 V c; 12 V c, redundant capable
2 x PoE per IEEE802.3af, redundant capable (2)
2 x 24 V c; 12 V c, redundant capable
2 x PoE per IEEE802.3af, redundant capable (2)
2 x 24 V c; 12 V c, redundant capable
1 x PoE per IEEE802.3af (2)
Current consumption 12 V c: 625 mA; 24 V c: 417 mA
PoE (48 V c): 167 mA (2)
12 V c: 625 mA; 24 V c: 417 mA
PoE (48 V c): 167 mA (2)
Agency
certications
Safety EN 60950 EN 60950
Radio EN 300328, EN 301893, notied in EU
countries
FCC identier: U99BAT54RAIL, IC certication
number: 4019A-BAT54R
EN 300328, EN 301893, notied in EU countries
Environment EN 61131, EN 61131 for operation in automation environment.
EMC test documentation for E1 certication (cars and vehicles) available
EN 61131, EN 61131 for operation in automation environment. EMC test documentation for E1 certication (cars and vehicles) available
References TCSGWA242 (3) TCSGWA242F (3) TCSGWA272 (3) TCSGWC241 (3)
Page 3/58 3/58
(1) SSID: Service Set IDentier
(2) PoE: Power over Ethernet
(3) TCSGpppppp products are supplied with
2 pen-type antennas
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/49
Type of device Wi-Fi 802.11g Access Point Wi-Fi 802.11g Access Point FCC Wi-Fi 802.11g Access Point IP 67 Wi-Fi 802.11g Client
Description Dual band industrial wireless LAN
Access Point/Client with two independent
radio modules based on IEEE 802.11a/b/g/h/i.
Dual band industrial wireless LAN
Access Point/Client with two independent
radio modules, based on IEEE 802.11a/b/g/h/i.
With FCC-approval for USA and Canada.
Dual band industrial wireless LAN Access Point/Client with two independent
radio modules based on IEEE 802.11a/b/g/h/i for installation in harsh
environment, IP 67 rated.
Single band industrial wireless LAN Client with one radio module based on IEEE
802.11a/b/g/h/i.
Type Access Point and Client Access Point and Client Client only
Wireless standard IEEE 802.11a/b/g/h/i IEEE 802.11a/b/g/h/i
Operating frequencies 2.4 GHz and 5 GHz 2.4 GHz and 5 GHz
Degree of protection IP 40 IP 67 IP 40
Regional approvals – FCC
Mounting DIN rail Wall/mast DIN rail
Number of radios 2 2 1
Nominal data rate 54 Mbps 54 Mbps
Antenna connections 4 x RP-SMA 4 x N-type 4 x RP-SMA
Ethernet connections 2 x 10/100BASE-TX 1 x 10/100BASE-TX
Wireless connections 2 x WLAN interfaces, 8 SSIDs per interface (1) 2 x WLAN interfaces, 8 SSIDs per interface (1) 1 x WLAN interface
Range Up to 20 km with external antenna (depending on type of antenna, frequency range and data
rate)
Up to 20 km with external antenna (depending on type of antenna, frequency range and data rate)
Dimensions 80 x 100 x 135 mm 261 x 189 x 55 mm 80 x 100 x 135 mm
Operating temperature -30°C to +50°C -30°C to +55°C
Storage temperature -40°C to +70°C -40°C to +70°C
Humidity Max. 95% (non-condensing) Max. 95% (non-condensing)
Power supplies 2 x 24 V c; 12 V c, redundant capable
2 x PoE per IEEE802.3af, redundant capable (2)
2 x 24 V c; 12 V c, redundant capable
2 x PoE per IEEE802.3af, redundant capable (2)
2 x 24 V c; 12 V c, redundant capable
1 x PoE per IEEE802.3af (2)
Current consumption 12 V c: 625 mA; 24 V c: 417 mA
PoE (48 V c): 167 mA (2)
12 V c: 625 mA; 24 V c: 417 mA
PoE (48 V c): 167 mA (2)
Agency
certications
Safety EN 60950 EN 60950
Radio EN 300328, EN 301893, notied in EU
countries
FCC identier: U99BAT54RAIL, IC certication
number: 4019A-BAT54R
EN 300328, EN 301893, notied in EU countries
Environment EN 61131, EN 61131 for operation in automation environment.
EMC test documentation for E1 certication (cars and vehicles) available
EN 61131, EN 61131 for operation in automation environment. EMC test documentation for E1 certication (cars and vehicles) available
References TCSGWA242 (3) TCSGWA242F (3) TCSGWA272 (3) TCSGWC241 (3)
Page 3/58 3/58
(1) SSID: Service Set IDentier
(2) PoE: Power over Ethernet
(3) TCSGpppppp products are supplied with
2 pen-type antennas
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/50
Selection guide (continued) Modicon M340
automation platform
Cabling systems for Wi-Fi networks
Wi-Fi access points and clients
Type of device Wi-Fi 802.11n Access Point Wi-Fi 802.11n Access Point FCC Wi-Fi 802.11n Access Point IP 67 Wi-Fi 802.11n Access Point IP 67 FCC Wi-Fi 802.11n Access Point IP 67 ATEX
Description Dual band industrial high performance
wireless LAN Access Point/Client with
one radio module based on IEEE 802.11n
(draft 2.0).
Dual band industrial high performance wireless
LAN Access Point/Client with one radio module
based on IEEE 802.11n (draft 2.0). With
FCC-approval for USA and Canada.
Dual band industrial high performance wireless LAN
Access Point/Client with one radio module based on
IEEE 802.11n (draft 2.0).
For installation in harsh environment, IP 67 rated.
Dual band industrial high performance wireless LAN
Access Point/Client with one radio module based on
IEEE 802.11n (draft 2.0). For installation in harsh
environment, IP 67 rated. With FCC-approval for
USA and Canada.
Dual band industrial high performance wireless LAN
Access Point/Client with one radio module based on
IEEE 802.11n (draft 2.0). For installation in harsh
environment, IP 67 ATEX Zone II rated. With
FCC-approval for USA and Canada
Type Access point and Client Access point and Client
Wireless standard IEEE 802.11a/b/g/h/n IEEE 802.11a/b/g/h/n
Operating frequencies 2.4 GHz and 5 GHz 2.4 GHz and 5 GHz
Degree of protection IP 40 IP 67 IP 67 ATEX
Regional approvals – FCC FCC
Mounting DIN rail Wall/mast
Number of radios 1 1
Nominal data rate 300 Mbps 300 Mbps
Antenna connections 3 x RP-SMA 3 x N-type
Ethernet connections 2 x 10/100BASE-TX 2 x 10/100BASE-TX
Wireless connections 1 x WLAN interface, 8 SSIDs per interface (1) 1 x WLAN interface, 8 SSIDs per interface (1)
Range Up to 20 km with external antenna (depending on type of antenna, frequency range and data
rate)
Up to 20 km with external antenna (depending on type of antenna, frequency range and data rate)
Dimensions 80 x 100 x 135 mm 261 x 189 x 55 mm
Operating temperature -30°C to +50°C -30°C to +55°C
Storage temperature -40°C to +70°C -40°C to +70°C
Humidity Max. 95% (non-condensing) Max. 95% (non-condensing)
Power supplies 2 x 24 V c; 12 V c, redundant capable
2 x PoE per IEEE802.3af, redundant capable (2)
2 x 24 V c, redundant capable
2 x PoE per IEEE802.3af, redundant capable (2)
Current consumption 12 V c: 625 mA; 24 V c: 417 mA
PoE (48 V c): 167 mA (2)
24 V c: 417 mA
PoE (48 V c): 167 mA (2)
Agency
certications
Safety EN 60950 EN 60950
Radio EN 300328, EN 301893, notied in EU
countries
Certications for FCC EN 300328, EN 301893, notied in EU countries
Environment EN 61131 for operation in automation environment EN 61000-6-2, EN 61131
EN 50155 (in preparation)
E1 (in preparation)
EN 61131 for operation in automation environment EN 61000-6-2, EN 61131 ATEX Zone II
References TCSNWA241 (3) TCSNWA241F (3) TCSNWA271 (3) TCSNWA271F (3) TCSNWA2A1 (3)
Page 3/58 3/58
(1) SSID: Service Set IDentier
(2) PoE: Power over Ethernet
(3) TCSN pp pppp products are supplied with
3 pen-type antennas
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/51
Type of device Wi-Fi 802.11n Access Point Wi-Fi 802.11n Access Point FCC Wi-Fi 802.11n Access Point IP 67 Wi-Fi 802.11n Access Point IP 67 FCC Wi-Fi 802.11n Access Point IP 67 ATEX
Description Dual band industrial high performance
wireless LAN Access Point/Client with
one radio module based on IEEE 802.11n
(draft 2.0).
Dual band industrial high performance wireless
LAN Access Point/Client with one radio module
based on IEEE 802.11n (draft 2.0). With
FCC-approval for USA and Canada.
Dual band industrial high performance wireless LAN
Access Point/Client with one radio module based on
IEEE 802.11n (draft 2.0).
For installation in harsh environment, IP 67 rated.
Dual band industrial high performance wireless LAN
Access Point/Client with one radio module based on
IEEE 802.11n (draft 2.0). For installation in harsh
environment, IP 67 rated. With FCC-approval for
USA and Canada.
Dual band industrial high performance wireless LAN
Access Point/Client with one radio module based on
IEEE 802.11n (draft 2.0). For installation in harsh
environment, IP 67 ATEX Zone II rated. With
FCC-approval for USA and Canada
Type Access point and Client Access point and Client
Wireless standard IEEE 802.11a/b/g/h/n IEEE 802.11a/b/g/h/n
Operating frequencies 2.4 GHz and 5 GHz 2.4 GHz and 5 GHz
Degree of protection IP 40 IP 67 IP 67 ATEX
Regional approvals – FCC FCC
Mounting DIN rail Wall/mast
Number of radios 1 1
Nominal data rate 300 Mbps 300 Mbps
Antenna connections 3 x RP-SMA 3 x N-type
Ethernet connections 2 x 10/100BASE-TX 2 x 10/100BASE-TX
Wireless connections 1 x WLAN interface, 8 SSIDs per interface (1) 1 x WLAN interface, 8 SSIDs per interface (1)
Range Up to 20 km with external antenna (depending on type of antenna, frequency range and data
rate)
Up to 20 km with external antenna (depending on type of antenna, frequency range and data rate)
Dimensions 80 x 100 x 135 mm 261 x 189 x 55 mm
Operating temperature -30°C to +50°C -30°C to +55°C
Storage temperature -40°C to +70°C -40°C to +70°C
Humidity Max. 95% (non-condensing) Max. 95% (non-condensing)
Power supplies 2 x 24 V c; 12 V c, redundant capable
2 x PoE per IEEE802.3af, redundant capable (2)
2 x 24 V c, redundant capable
2 x PoE per IEEE802.3af, redundant capable (2)
Current consumption 12 V c: 625 mA; 24 V c: 417 mA
PoE (48 V c): 167 mA (2)
24 V c: 417 mA
PoE (48 V c): 167 mA (2)
Agency
certications
Safety EN 60950 EN 60950
Radio EN 300328, EN 301893, notied in EU
countries
Certications for FCC EN 300328, EN 301893, notied in EU countries
Environment EN 61131 for operation in automation environment EN 61000-6-2, EN 61131
EN 50155 (in preparation)
E1 (in preparation)
EN 61131 for operation in automation environment EN 61000-6-2, EN 61131 ATEX Zone II
References TCSNWA241 (3) TCSNWA241F (3) TCSNWA271 (3) TCSNWA271F (3) TCSNWA2A1 (3)
Page 3/58 3/58
(1) SSID: Service Set IDentier
(2) PoE: Power over Ethernet
(3) TCSN pp pppp products are supplied with
3 pen-type antennas
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/52
Selection guide Modicon M340
automation platform
Cabling systems for Wi-Fi networks
Wi-Fi antennas
Type of device Dual band antennas Dual band antenna
Description Dual band hemispherical antenna 5 GHz Very directional antenna Dual band omni directional 11n antenna
Frequency range 2300 - 2500 MHz
4900 - 5935 MHz
5150 - 5250 MHz
5250 - 5350 MHz
5350 - 5725 MHz
5725 - 5875 MHz
2400 - 2500 MHz
5150 - 5875 MHz
Antenna gain 6 dBi at 2.4 GHz
8 dBi at 5 GHz
18 dBi
19 dBi
18.5 dBi
18 dBi
3.5 dBi
5.5 dBi
VSWR (1) 1.8 1.5 1.8
Polarization Linear, vertical 3 x linear, vertical
HPBW Horizontal (2) 360° at 2.4 GHz 18° 360°
HPBW Vertical (2) 173° at 5 GHz 18°
Max. power 75 W (CW) at 25°C 6 W (CW) 2 W
Impedance 50 Ω 50 Ω
Connector N female N female 3 x N male, 1 m cable directly attached to antenna
Operating temperature -40°C to +80°C -45°C to +70°C -40°C to +80°C
Storage temperature -40°C to +80°C -45°C to +70°C -40°C to +80°C
Radome color RAL 7044 (Silk gray) 7035 (Light gray) 7035 (Light gray)
Radome material LEXAN EXL 9330 Plastic Plastic
Weight 0.3 kg 0.107 kg 0.3 kg
Dimensions ø 86 x 43 mm 190 x 190 x 30.5 mm 310 x 110 x 40 mm
Wind load 10 N at 160 km/h 104 N at 216 km/h
Degree of protection IP 65 IP 65/IP 67 IP 65
Shipping package contents Cordset/cable 1 m cordset with N male connectors at both ends 3 x 90 cm cordset directly attached to antenna, with N male connector
Adapter cable Adapter cable, R-SMA male connector to N female connector 3 x adapter cables, R-SMA male connector to N female connector
Mounting kit Yes Yes
Compatibility of access points and clients TCSGpppppp TCSNpppppp
References TCSWABDH TCSWAB5V TCSWABDON
Page 3/59 3/59
(1) VSWR: Voltage Standing Wave Ratio
(2) HPBW: Half Power BeamWidth
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/53
Type of device Dual band antennas Dual band antenna
Description Dual band hemispherical antenna 5 GHz Very directional antenna Dual band omni directional 11n antenna
Frequency range 2300 - 2500 MHz
4900 - 5935 MHz
5150 - 5250 MHz
5250 - 5350 MHz
5350 - 5725 MHz
5725 - 5875 MHz
2400 - 2500 MHz
5150 - 5875 MHz
Antenna gain 6 dBi at 2.4 GHz
8 dBi at 5 GHz
18 dBi
19 dBi
18.5 dBi
18 dBi
3.5 dBi
5.5 dBi
VSWR (1) 1.8 1.5 1.8
Polarization Linear, vertical 3 x linear, vertical
HPBW Horizontal (2) 360° at 2.4 GHz 18° 360°
HPBW Vertical (2) 173° at 5 GHz 18°
Max. power 75 W (CW) at 25°C 6 W (CW) 2 W
Impedance 50 Ω 50 Ω
Connector N female N female 3 x N male, 1 m cable directly attached to antenna
Operating temperature -40°C to +80°C -45°C to +70°C -40°C to +80°C
Storage temperature -40°C to +80°C -45°C to +70°C -40°C to +80°C
Radome color RAL 7044 (Silk gray) 7035 (Light gray) 7035 (Light gray)
Radome material LEXAN EXL 9330 Plastic Plastic
Weight 0.3 kg 0.107 kg 0.3 kg
Dimensions ø 86 x 43 mm 190 x 190 x 30.5 mm 310 x 110 x 40 mm
Wind load 10 N at 160 km/h 104 N at 216 km/h
Degree of protection IP 65 IP 65/IP 67 IP 65
Shipping package contents Cordset/cable 1 m cordset with N male connectors at both ends 3 x 90 cm cordset directly attached to antenna, with N male connector
Adapter cable Adapter cable, R-SMA male connector to N female connector 3 x adapter cables, R-SMA male connector to N female connector
Mounting kit Yes Yes
Compatibility of access points and clients TCSGpppppp TCSNpppppp
References TCSWABDH TCSWAB5V TCSWABDON
Page 3/59 3/59
(1) VSWR: Voltage Standing Wave Ratio
(2) HPBW: Half Power BeamWidth
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/54
Selection guide (continued) Modicon M340
automation platform
Cabling systems for Wi-Fi networks
Wi-Fi antennas
Type of device 5 GHz antennas 5 GHz antennas
Description 5 GHz omni directional antenna 5 GHz dual slant antenna 5 GHz directional - MiMo 11n antenna (3) 5 GHz Medium directional antenna 5 GHz Very directional 11n antenna
Frequency range 5150 - 5875 MHz 5150 - 5925 MHz 5150 - 5875 MHz 5150 - 5250 MHz
5250 - 5350 MHz
5350 - 5725 MHz
5725 - 5875 MHz
5150 - 5875 MHz
Antenna gain 5 dBi 9 dBi 9 dBi 18 dBi
19 dBi
18.5 dBi
18 dBi
23 dBi
VSWR (1) 1.5 2 1.5 1.5 < 1.7
Polarization Linear, vertical 2 x linear, ± 45° slant 3 x linear vertical/horizontal/+45° Linear, vertical Dual linear, vertical and horizontal
HPBW Horizontal (2) 360° 70° 65° 18° 9°
HPBW Vertical (2) 25° 60° 65° 18° 9°
Max. power 6 W 10 W (CW) at 25°C 2 W (CW) at 25°C 6 W (CW) 6 W
Impedance 50 Ω 50 Ω
Connector N female 2 x N female N female N female 2 x N female
Operating temperature -45°C to +70°C -40°C to +80°C -40°C to +80°C -45°C to +70°C
Storage temperature -45°C to +70°C -40°C to +80°C -40°C to +80°C -45°C to +70°C
Radome color Gray-white RAL 7044 (Silk gray) RAL 7044 (Silk gray) 7035 (Light gray) Gray-white
Radome material Polypropylene ASA, LEXAN EXL 9330 LEXAN EXL 9330 Plastic
Weight 0.300 kg 0.110 kg 0.110 kg 0.107 kg 2.5 kg
Dimensions 16 x 160 mm 101 x 80 x 35 mm 101 x 80 x 35 mm 190 x 190 x 30.5 mm 371 x 371 x 40 mm
Wind load 15 N at 160 km/h 15 N at 160 km/h 264 N at 220 km/h
Degree of protection IP 65 IP 65 IP 65/IP 67
Shipping package contents Cordset/cable 1 m cordset with N male connectors at both
ends
2 x 1 m cordset with N male connectors at both
ends
3 x 1 m cordset with N male connectors at both ends 1 m cordset with N male connectors at both ends 2 x 1 m cordset with N male connectors at both ends
Adapter cable Adapter cable, R-SMA male connector to
N female connector
2 x adapter cables, R-SMA male connector to
N female connector
3 x adapter cables, R-SMA male connector to
N female connector
Adapter cable, R-SMA male connector to
N female connector
2 x adapter cables, R-SMA male connector to
N female connector
Mounting kit Yes Yes
Compatibility of access points and clients TCSGpppppp TCSGpppppp
TCSNpppppp TCSNpppppp TCSGpppppp TCSGpppppp
TCSNpppppp
References TCSWAB5O TCSWAB5S TCSWAB5DN TCSWAB5D TCSWAB5VN
Page 3/59 3/59
(1) VSWR: Voltage Standing Wave Ratio
(2) HPBW: Half Power BeamWidth
(3) MiMo: Multiple-Input Multiple-Output
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/55
Type of device 5 GHz antennas 5 GHz antennas
Description 5 GHz omni directional antenna 5 GHz dual slant antenna 5 GHz directional - MiMo 11n antenna (3) 5 GHz Medium directional antenna 5 GHz Very directional 11n antenna
Frequency range 5150 - 5875 MHz 5150 - 5925 MHz 5150 - 5875 MHz 5150 - 5250 MHz
5250 - 5350 MHz
5350 - 5725 MHz
5725 - 5875 MHz
5150 - 5875 MHz
Antenna gain 5 dBi 9 dBi 9 dBi 18 dBi
19 dBi
18.5 dBi
18 dBi
23 dBi
VSWR (1) 1.5 2 1.5 1.5 < 1.7
Polarization Linear, vertical 2 x linear, ± 45° slant 3 x linear vertical/horizontal/+45° Linear, vertical Dual linear, vertical and horizontal
HPBW Horizontal (2) 360° 70° 65° 18° 9°
HPBW Vertical (2) 25° 60° 65° 18° 9°
Max. power 6 W 10 W (CW) at 25°C 2 W (CW) at 25°C 6 W (CW) 6 W
Impedance 50 Ω 50 Ω
Connector N female 2 x N female N female N female 2 x N female
Operating temperature -45°C to +70°C -40°C to +80°C -40°C to +80°C -45°C to +70°C
Storage temperature -45°C to +70°C -40°C to +80°C -40°C to +80°C -45°C to +70°C
Radome color Gray-white RAL 7044 (Silk gray) RAL 7044 (Silk gray) 7035 (Light gray) Gray-white
Radome material Polypropylene ASA, LEXAN EXL 9330 LEXAN EXL 9330 Plastic
Weight 0.300 kg 0.110 kg 0.110 kg 0.107 kg 2.5 kg
Dimensions 16 x 160 mm 101 x 80 x 35 mm 101 x 80 x 35 mm 190 x 190 x 30.5 mm 371 x 371 x 40 mm
Wind load 15 N at 160 km/h 15 N at 160 km/h 264 N at 220 km/h
Degree of protection IP 65 IP 65 IP 65/IP 67
Shipping package contents Cordset/cable 1 m cordset with N male connectors at both
ends
2 x 1 m cordset with N male connectors at both
ends
3 x 1 m cordset with N male connectors at both ends 1 m cordset with N male connectors at both ends 2 x 1 m cordset with N male connectors at both ends
Adapter cable Adapter cable, R-SMA male connector to
N female connector
2 x adapter cables, R-SMA male connector to
N female connector
3 x adapter cables, R-SMA male connector to
N female connector
Adapter cable, R-SMA male connector to
N female connector
2 x adapter cables, R-SMA male connector to
N female connector
Mounting kit Yes Yes
Compatibility of access points and clients TCSGpppppp TCSGpppppp
TCSNpppppp TCSNpppppp TCSGpppppp TCSGpppppp
TCSNpppppp
References TCSWAB5O TCSWAB5S TCSWAB5DN TCSWAB5D TCSWAB5VN
Page 3/59 3/59
(1) VSWR: Voltage Standing Wave Ratio
(2) HPBW: Half Power BeamWidth
(3) MiMo: Multiple-Input Multiple-Output
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/56
Selection guide (continued) Modicon M340
automation platform
Cabling systems for Wi-Fi networks
Wi-Fi antennas
Type of device 2.4 GHz antennas Antenna cables
Description 2.4 GHz omni directional
antenna
2.4 GHz directional
antenna
2.4 GHz dual slant
antenna
2.4 GHz Leaky cable, 50 m 2.4 GHz Leaky cable, 100 m
Frequency range 2400 - 2500 MHz 2300 - 2500 MHz 2400 - 2485 MHz 2000 - 2900 MHz
Antenna gain 6.0 dBi 14 dBi 8 dBi 0.15 dB at 2.4 GHz
VSWR (1) < 1.8 1.5
Polarization Linear, vertical Vertical Dual linear,
± 45° slant
HPBW Horizontal (2) 360° 35° 75°
HPBW Vertical (2) 30° 70°
Max. power 25 W 75 W (CW) at 25°C 10 W (CW) at 25°C
Impedance 50 Ω
Connector N female 2 x N female 2 x N male
Operating temperature -40°C to +80°C -40°C to +85°C
Storage temperature -40°C to +80°C -70°C to +85°C
Radome color Gray-white RAL 7044 (Silk gray)
Radome material Fiber glass LEXAN EXL 9330
Weight 0.340 kg 0.110 kg 12 kg 24 kg
Dimensions ø 22 mm x 250 mm 101 x 80 x 35 mm 50 m, ø 15 mm 100 m, ø 15 mm
Wind load 15 N at 160 km/h
Degree of protection IP 65 IP 23 IP 65 IP 65
Shipping package contents Cordset/cable 1 m cordset with N male connectors at both ends 2 x 1 m cordset with N male
connectors at both ends
50 m cable with N male connectors at both ends 100 m cable with N male connectors at both ends
Adapter cable Adapter cable, R-SMA male connector to N female connector 2 x adapter cables,
R-SMA male to N female
Mounting kit Yes 1 x 50 Ohm terminator, 50 fastening clips (mounting on at surface)
Compatibility of access points and clients TCSGpppppp TCSGpppppp TCSGpppppp
TCSNpppppp TCSGpppppp
References TCSWAB2O TCSWAB2D TCSWAB2S TCSWABC5 TCSWABC10
Page 3/59 3/59
(1) VSWR: Voltage Standing Wave Ratio
(2) HPBW: Half Power BeamWidth
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/57
Type of device 2.4 GHz antennas Antenna cables
Description 2.4 GHz omni directional
antenna
2.4 GHz directional
antenna
2.4 GHz dual slant
antenna
2.4 GHz Leaky cable, 50 m 2.4 GHz Leaky cable, 100 m
Frequency range 2400 - 2500 MHz 2300 - 2500 MHz 2400 - 2485 MHz 2000 - 2900 MHz
Antenna gain 6.0 dBi 14 dBi 8 dBi 0.15 dB at 2.4 GHz
VSWR (1) < 1.8 1.5
Polarization Linear, vertical Vertical Dual linear,
± 45° slant
HPBW Horizontal (2) 360° 35° 75°
HPBW Vertical (2) 30° 70°
Max. power 25 W 75 W (CW) at 25°C 10 W (CW) at 25°C
Impedance 50 Ω
Connector N female 2 x N female 2 x N male
Operating temperature -40°C to +80°C -40°C to +85°C
Storage temperature -40°C to +80°C -70°C to +85°C
Radome color Gray-white RAL 7044 (Silk gray)
Radome material Fiber glass LEXAN EXL 9330
Weight 0.340 kg 0.110 kg 12 kg 24 kg
Dimensions ø 22 mm x 250 mm 101 x 80 x 35 mm 50 m, ø 15 mm 100 m, ø 15 mm
Wind load 15 N at 160 km/h
Degree of protection IP 65 IP 23 IP 65 IP 65
Shipping package contents Cordset/cable 1 m cordset with N male connectors at both ends 2 x 1 m cordset with N male
connectors at both ends
50 m cable with N male connectors at both ends 100 m cable with N male connectors at both ends
Adapter cable Adapter cable, R-SMA male connector to N female connector 2 x adapter cables,
R-SMA male to N female
Mounting kit Yes 1 x 50 Ohm terminator, 50 fastening clips (mounting on at surface)
Compatibility of access points and clients TCSGpppppp TCSGpppppp TCSGpppppp
TCSNpppppp TCSGpppppp
References TCSWAB2O TCSWAB2D TCSWAB2S TCSWABC5 TCSWABC10
Page 3/59 3/59
(1) VSWR: Voltage Standing Wave Ratio
(2) HPBW: Half Power BeamWidth
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
3/58
References
Wi-Fi Access Points and Clients
Description Number
of radios
Data rate Degree of
protection
Country
approvals
Reference Weight
Mbps kg
Wi-Fi 802.11g
Access Point
2 54 IP 40 TCSGWA242
Wi-Fi 802.11g
Access Point FCC
2 54 IP 40 US and Canada TCSGWA242F
Wi-Fi 802.11g
Access Point IP 67
2 54 IP 40 TCSGWA272
Wi-Fi 802.11g Client 1 54 IP 40 TCSGWC241
Wi-Fi 802.11n
Access Point
1 300 IP 40 TCSNWA241
Wi-Fi 802.11n
Access Point FCC
1 300 IP 40 US and Canada TCSNWA241F
Wi-Fi 802.11n
Access Point IP 67
1 300 IP 67 TCSNWA271
Wi-Fi 802.11n
Access Point IP 67 FCC
1 300 IP 67 US and Canada TCSNWA271F
Wi-Fi 802.11n
Access Point IP 67 ATEX
1 300 IP 67 ATEX TCSNWA2A1
Wi-Fi antennas
Description Frequency
range
Gain Degree of
protection
Reference Weight
MHz dBi kg
Dual band hemispherical
antenna
2300 - 2500 6 IP 65 TCSGWABDH 0.300
4900 - 5935 8
5 GHz Very
directional antenna
5150 - 5250 18 IP 67/IP 65 TCSWAB5V 0.107
5250 - 5350 19
5350 - 5725 18.5
5725 - 5875 18
Dual band omni
directional 11n antenna
2400 - 2500 3.5 IP 65 TCSWABDON 0.300
5150 - 5875 5.5
5 GHz omni
directional antenna
5150 - 5875 5 IP 65 TCSWAB5O 0.300
5 GHz dual slant antenna 5150 - 5925 9 IP 65 TCSWAB5S 0.110
5 GHz directional - MiMo
11n antenna
5150 - 5875 9 IP 65 TCSWAB5DN 0.110
5 GHz Medium
directional antenna
5150 - 5250 18 IP 67/IP 65 TCSWAB5D 0.107
5250 - 5350 19
5350 - 5725 18.5
5725 - 5875 18
5 GHz Very
directional 11n antenna
5150 - 5875 23 IP 67/IP 65 TCSWAB5VN 2.500
2.4 GHz omni
directional antenna
2400 - 2500 6 IP 65 TCSWAB2O 0.340
References Modicon M340
automation platform
Cabling systems for Wi-Fi networks
Wi-Fi access points and clients
TCSNWA271
TCSWABDH
TCSWAB5DN
TCSWAB2O
TCSWAB5D
TCSGWA242
TCSNWA241
1
2
3
4
5
6
7
8
9
10
3/59
Wi-Fi antennas (continued)
Description Frequency range MHz Gain Degree of
protection
Reference Weight
kg
2.4 GHz
directional antenna
2300 - 2500 14 dBi IP 23 TCSWAB2D 0.110
2.4 GHz dual
slant antenna
2400 - 2485 8 dBi IP 65 TCSWAB2S 0.110
2.4 GHz Leaky cable
50 m
2000 - 2900 0.15 dB
at 2.4 GHz
IP 65 TCSWABC5 12
2.4 GHz Leaky cable
100 m
2000 - 2900 0.15 dB
at 2.4 GHz
IP 65 TCSWABC10 24
Cables
Description Type Length
m
Reference Weight
kg
Adapter cable 1 RP-SMA male connector
1 N female connector
0.520 TCSWAAC 0.340
Adapter cable
N-plug to N-jack, 2 m
1 N female connector
1 N male connector
2.000 TCSWABAC2 0.340
Adapter cable
N-plug to N-jack, 15 m
1 N female connector
1 N male connector
15.000 TCSWABAC15 0.340
Accessories
Description Frequency range Type Cable length
m
Reference Weight
kg
Overvoltage protector for
antennas
N female,
N male
TCSWABP 0.080
Overvoltage protector for
LAN/PoE
IP 68 N female,
N male
TCSWABP68 0.080
Memory card modules
(1)
IP 40 Mini-DIN
connector
0.315 TCSWAMC67 0.035
IP 67 M12 connector 0.500 TCSWAMCD 0.025
Adapter kit for pole
mounting
– – TCSWABMK
(1) Auto-conguration adapter that is used to save 2 different versions of the conguration and operating program data for the
Wi-Fi access point to which it is connected. It enables managed Wi-Fi access points to be easily commissioned and quickly
replaced.
References (continued) Modicon M340
automation platform
Cabling systems for Wi-Fi networks
Wi-Fi antennas, cables and accessories
TCSWAB2D
TCSWABC5
TCSWAAC
TCSWABP
TCSWAMCD
TCSWABAC2
TCSWABMK
1
2
3
4
5
6
7
8
9
10
3/60
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Introduction Modicon M340
automation platform
Modbus Plus Proxy module
Introduction
The TCSEGDB23F24FA Modbus Plus Proxy module (also called M340EGD) is a
network gateway that allows the Modicon M340 PAC to communicate with existing
Modbus Plus devices.
It is not necessary to modify the applications for these devices to communicate with
the Modicon M340 PAC, since the module automatically addresses the platforms
and the various communication functions between the M340 and other PAC
platforms (especially 984LL).
The M340 Modbus Plus Proxy offers Modbus Plus PAC users the chance to
integrate the M340 PAC easily into their Modbus Plus network and thus access to
advanced communications via Ethernet, or to migrate gradually from other PAC
models to Modicon M340 and Unity.
Compact 984
Distributed I/O
Modbus Plus
SCADA
Modbus Plus
Proxy
Web
conguration
interface
Modicon M340 PAC
Ethernet
Key benets
Reduced startup time
Online conguration of the proxy via a simple Web browser b
Setup Web pages similar to the screens of the Modbus Plus Peer Cop utility, b
accessible under Concept/Unity for the Global Data transaction
Simpler data exchange with Global Data transactions performed on network nodes b
Point-to-point communication without programming with Peer Cop b
Increased network reliability and maintainability
Standard diagnostics provide data on network nodes for easy troubleshooting b
Dual Modbus Plus ports provide Modbus Plus network redundancy b
Reduced cost of ownership
Helps protect your investment in Modbus Plus while migrating to Ethernet b
Dual Ethernet ports allow connection of both the M340 PAC and the conguration b
PC to the proxy, without any additional switches
1
2
3
4
5
6
7
8
9
10
3/61
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Modbus Plus Proxy module
References
Embedded Web server
Web server functions
The M340EGD includes an embedded Web server that can be used to perform
diagnostics and congure the module connection. The data is presented as standard
Web pages in HTML format. To access a Web page, you need Internet Explorer 6.0
(or later version) and Java 1.5 (or later version).
Embedded Web server functions
1 - Setup: The Setup pages allow you to dene the parameters for several different
module services, including security, IP, SNMP, Global Data, Peer Cop and Ethernet
ports.
2 - Diagnostics: These network diagnostic pages contain Ethernet, TCP and SNMP
statistics, as well as a log of the diagnostics performed.
Complementary Specications
The following specications complement those introduced in the communication
selection guide on page 3/6:
External power supply voltage: 19.2 to 31.2 V b c
Consumption: 300 mA max. b
Dissipated power: 6.2 W b
Conformity with standards: UL 508, CSA 22.2 No. 142 (cUL), EMI EN 55011, b
EN 61131-2, C-Tick
References
System and network requirements
Unity Pro XL 3.x programming software (or later version)
Internet Explorer 6.0 (or later version)
Java 1.5 (or later version)
Microsoft Windows XP or Windows Vista
Modicon M340 processor:
BMXP342020 (Modbus b and Ethernet version)
BMXP3420302 (CANopen and Ethernet version) b
Ethernet Modicon M340 communication modules:
BMXNOE0100 b
BMXNOE0110 b
BMXNOC0401 b
Modicon M340 Modbus Plus Proxy module
Description Type Reference Weight
kg
Modbus Plus Proxy module
for Modicon M340 PAC
supplied with 2 front-mounted
power supply connectors
(2 positions)
Standard TCSEGDB23F24FA
Conformal coating TCS EGDB23F24FK
TCSEGDB23F24FA
1
2
3
4
5
6
7
8
9
10
3/62
Introduction Modicon M340
automation platform
Probus Remote Master modules
Probus DP eldbus
Probus DP is one of the most widely used eldbuses in the industry, and is based
on a master/slave protocol.
Version V0 of Probus only allows cyclic exchanges with I/O, whereas version V1
offers an acyclic message handling channel that can be used for adjustment or
diagnostics of devices during operation.
The physical link is a single shielded twisted pair, but numerous interfaces are
available for creating different types of topologies - tree, star or ring - including those
using ber optics or a non-physical link.
Gateways can be used to communicate transparently with Probus PA. Probus PA
can be used to supply devices across the network and also to install sensors in
potentially explosive zones (ATEX).
Unity V5.0
PRM master DTM
PRM Com DTM
Ethernet
Probus PA
PRM Probus DP
DP Class 1
Probus Remote Master (PRM) module
Introduction
The Probus Remote Master (PRM) module is connected to the Ethernet Modbus
TCP/IP network via its integrated 2-port switch, as close as possible to the process
and the instrumentation.
The PRM module can be used to connect Quantum, Premium and M340 PACs
to Probus DP V1 via the I/O scanner function.
Regardless of the type of PAC, only one product reference is required and setup is
identical, thus reducing training and maintenance costs.
Two versions are available, standard and "tropicalized", to adapt to any type of
environment.
The PRM module is open to Asset Management tools.
A dedicated communication DTM is supplied with the product, thus allowing any
compatible FDT standard tool to remotely adjust devices on Probus using Ethernet
(see page 4/4).
Conguration
From a single Unity tool, the user can create the Probus conguration, the PAC
application and congure or calibrate devices.
The latter are integrated in the Unity catalog via their DTMs if they exist, or their
gsd les.
The I/O scanner conguration is created implicitly in Unity Pro using the Probus
conguration. The parameters assigned by default help to guarantee optimized
performance, as well as providing consistency of I/O data in the PAC application,
regardless of the PAC platform.
Similarly, the I/O variables dened and presymbolized in the DTMs can be used directly
in the application. Finally, the screens integrated in Unity Pro, plus the diagnostic
functions integrated in the device DTMs, simplify application maintenance.
1
2
3
4
5
6
7
8
9
10
3/63
Modicon M340
automation platform
Probus Remote Master modules
Introduction (continued),
references
Connectable devices
The following Schneider Electric devices can be connected to the Probus
Remote Master:
TeSys b U and TeSys T starter-controllers
Momentum b and Modicon STB distributed I/O
Modicon FTB/FTM I/O IP 67 monobloc and modular splitter boxes b
Altivar b 312/61/71 variable speed drives for asynchronous motors
Lexium b 05 and 15 variable speed drives for brushless motors
Altistart bATS 48 soft start-soft stop units
Any third-party device compatible with Probus b DP and PA standard proles
Limitations
Once saved, the Unity project incorporates the Probus parameters as well as the
slaves connected to the bus. Quantum, Premium and M340 PACs are capable of
embedding this data so that an empty Unity terminal without any applications is able,
after a simple transfer from the PAC, to locate the whole application, including the
slave parameters. This function is called ETS (Empty Terminal Service).
In certain cases, it may be that the memory size required to save the device
parameters exceeds the PAC memory capacity (signalled by a “memory full”
message during the build). This is particularly likely on devices that have DTM
(common to instrumentation on PA). Typically, each device of this type consumes
around 20 KB of the PAC memory.
Therefore, it is essential to create a memory map according to the type of conguration
being used. This memory map can be adapted either by increasing the amount of
memory dedicated to the application (by reducing the zone allocated to date), or by
increasing the overall memory using cartridges available in this catalog.
If the ETS function is not required, Unity Pro can also be congured in such a way as
to reduce the size of the embedded data by disabling comments and animation tables,
or by disabling the upload function, so that the application does not include data
relating to DTMs. In this case, the upload from an empty terminal function is no
longer available.
References
The Probus Remote Master module is supplied with a CD-ROM that includes:
PRM master DTMs and generic Probus DTMs (for conguration in Unity Pro V5.0 b
or later)
The PRM communication DTM for third-party (non-Schneider Electric) FDT b
Probus Remote Master modules
Description Type Reference Weight
kg
Probus Remote Master
modules
Standard TCSEGPA23F14F 0.620
Ruggedized (1) TCSEGPA23F14FK 0.620
Pre-cabled connection components to the Probus DP bus
Description Type Reference Weight
kg
Remote I/O
on Probus DP bus
Modicon STB
network interface module
STBNDP2112 0.140
Momentum communication
module
170DTN11000 0.070
Connectors for remote I/O
communication module
Line terminators 490NAD91103
Intermediate connection 490NAD91104
Intermediate connection
and terminal port
490NAD91105
Description Length Reference Weight
kg
Probus DP
connection cables
100 m TCXPBSCA100
400 m TCXPBSCA400
(1) Conformal coating and extended operating temperatures between -25 and +70°C.
See ruggedized module specications, page 6/2.
490NAD91103
TCSEGPA23F14F
1
2
3
4
5
6
7
8
9
10
3/64
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
CANopen machine and installation bus
Introduction
Introduction
FTB1CN
TeSys U
Osicoder
Altivar 71
drive
1 to 63
slaves
Premium PAC
Modicon M340 PAC
CANopen bus
Modicon STB
Altivar 312
drive
TeSys T
Schneider Electric has selected CANopen for use with its machines and
installations because of its wealth of functions and its adoption throughout the
automation world This decision was based on the general acceptance of CANopen,
and the fact that CANopen products are increasingly used in control system
architectures.
CANopen is an open network supported by more than 400 companies worldwide,
and promoted by CAN in Automation (CiA).
CANopen conforms to standards EN 50325-4 and ISO 15745-2.
CANopen brings transparency to Ethernet
CAN in Automation and Modbus-IDA have worked together to create a standard
that helps ensure transparency between CANopen and Modbus/TCP. The result of
this collaboration has been the CiA DSP309-2 specication that denes the
communication standards between a Modbus/TCP network and a CANopen bus.
This specication denes the mapping services that enable CANopen devices to
communicate with a Modbus/TCP network through a gateway. The data in a
CANopen device can be accessed in both read and write mode.
This specication is the rst standard available for developing open standard
communication between Modbus/TCP and CANopen. It is driving Schneider Electric
network solutions toward better integration, diagnostics and conguration of
distributed applications. It allows machines and installations to be connected to an
Ethernet network continuously, while combining the advantages of each network in
its specic area.
The CANopen bus is a multi-master bus that helps to ensure reliable, deterministic
access to real-time data in control system devices. The CSMA/CA protocol is based on
broadcast exchanges, sent cyclically or on an event, to help ensure optimum use of the
bandwidth. A message handling channel can also be used to dene slave parameters.
The bus uses a double shielded twisted pair on which, with the Modicon M340
platform, a maximum of 63 devices are connected by daisy-chaining or by tap
junctions. The variable data rate between 20 Kbps and 1 Mbps depends on the
length of the bus (between 20 m and 2500 m). Each end of the bus requires a
line terminator.
The Modicon M340 automation platform, via its BMXP3420102/20302 processor
with integrated CANopen link, performs the role of master on the bus.
Lexium 32
servo drive
1
2
3
4
5
6
7
8
9
10
3/65
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
CANopen machine and installation bus
Connectable devices
Connectable Schneider Electric devices
The following Schneider Electric devices can be connected to the CANopen bus,
depending on the model (1):
Osicoder b absolute encoders
TeSys b U starter-controllers with LUL C08 communication module
TeSys b T motor management system, with LTM controller
TeSys b D motor-starters using the TeSys Quickt installation help system with
APP 1CCO0/O2 communication module
Modicon bOTB IP 20 distributed I/O, with Twido I/O expansion modules and OTB
interface module
Modicon b STB IP 20 modular distributed I/O, with STB NIM interface module
Modicon b FTB monoblocand FTM modular IP 67 I/O splitter boxes
Preventa b congurable safety controllers
0.18 to 15 kW Altivar b 312/71/61 variable speed drives for asynchronous motors:
Lexium b 32 servo drives for BMH and BSH servo motors
IcLA intelligent compact motor-drives b
Integration of third-party devices
Unity
b Pro software version u 4.0 offers the Hardware Catalog Manager tool
that can be used to integrate third-party devices at an identical level to that of
Schneider Electric devices. These third-party devices and their EDS les conform to
the CiA (CAN In Automation) standard.
The Hardware Catalog Manager tool is used to:
Integrate third-party devices in Unity Pro v
Optimize the size of the v BMXP3420102/20302 processor memory area
reserved for PDO (Process Data Object) process variables
Customize the parameters specic to each third-party device v
Unity Pro software version
b u 4.1, combined with BMXP3420102/20302
processors with integrated CANopen link, can be used to customize conguration of
the device Boot Up procedure, and thus be compatible with commercially-available
CANopen third-party products.
___________________________________________________________________________
(1) See our website www.schneider-electric.com for compatible device versions and their
setup software.
Modicon FTB Modicon OTB
TeSys Quickt
Hardware Catalog Manager for integration of third-party devices
1
2
3
4
5
6
7
8
9
10
3/66
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
CANopen machine and installation bus
Description,
references
Description
BMXP3420102 and BMXP3420302 Performance processors on the Modicon
M340 platform have an integrated CANopen communication port. They feature
the following on the front panel:
1 Screw for locking the module in its slot in the rack, marked “00”.
2 Display block featuring:
CAN RUN LED (green): Integrated machine/installation bus operational v
CAN ERR LED (red): Integrated machine/installation bus detected fault v
3 Mini B USB connector for a programming terminal
4 Slot equipped with Flash memory card for backing up the application
5 RJ45 connector for serial link (with BMXP3420102 model) or Ethernet Modbus/
TCP port (with BMXP3420302 model)
6 9-way SUB-D connector for the CANopen master machine and installation bus
Complementary specications
The following specications complement those introduced in the communication
selection guide on page 3/4:
Data rate: 20 Kbps to 1 Mbps b
Maximum length of CANopen bus (1): b
20 m at 1 Mbps, 40 m at 800 Kbps, 100 m at 500 Kbps, 250 m at 250 Kbps v
500 m at 125 Kbps, 1000 m at 50 Kbps, 2500 m at 20 Kbps v
Maximum length of tap-offs on one tap junction (2): b
0.6 m at 1 Mbps, 6 m at 800 Kbps, 10 m at 500 Kbps, 10 m at 250 Kbps v
10 m at 125 Kbps, 120 m at 50 Kbps, 300 m at 20 Kbps v
Limitation per segment: b
Max. number of products: 64 at 1 Mbps, 32 at 800 Kbps, 16 at 500 Kbps v
Maximum length of segment (3): 160 m at 1 Mbps, 185 m at 800 Kbps, v
205 m at 500 Kbps
Modicon M340 Performance processors with integrated
CANopen bus link
Modicon M340 processor modules are supplied with the Flash card
BMXRMS008MP. This card performs the following actions transparently:
Backing up the application (program, symbols and constants) supported in the b
processor internal RAM that is not backed up
Activation of the Transparent Ready class B10 standard web server b
(with BMXP3420302 processor)
This card can be replaced by another card featuring a le storage option b
(see page 1/7).
Capacitance Max. no. of network/
bus modules
Integrated
communication
ports
Compatibility with
Unity software
(4)
Reference Weight
kg
Performance BMXP3420, 4 racks
1024 discrete I/O
256 analog I/O 36
application-specic
channels
4096 KB integrated
2 Ethernet Modbus/
TCP networks
4 AS-Interface buses
CANopen bus
Modbus serial link
Version u 4.1 BMXP3420102 0.210
CANopen bus
Ethernet network
Modbus/TCP
Version u 4.1 BMXP3420302 0.215
(1) Deduct 15 m per repeater from the length of the bus.
(2) For other restrictions, please refer to the CANopen hardware setup manual available on our website
www.schneider-electric.com.
(3) With the use of TSXCANCp50/100/300 CANopen cables and TSXCANCpDD03/1/3/5 preformed cordsets.
(4) See “Integration of third-party devices” paragraph on page 3/65.
2
3
5
1
4
6
BMXP3420102 BMXP3420302
BMXP3420302
BMXP3420102
1
2
3
4
5
6
7
8
9
10
3/67
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
CANopen machine and installation bus
Connections
CANopen bus cabling systems
9
10
2
55
17
1616
13
2
1
6a
6a6b
12
5
4
Altivar 312
drive Altivar 71
drive
Lexium 32 servo drive TeSys U
Modicon
OTB
Modicon STB
Modicon M340 with
BMXP3420102/20302 processor
PC or monitoring tool
Modicon FTB
24 V c
IcLA
Modicon FTB
Osicoder
Preventa
safety PLC
Magelis
XBTGp
TeSys T
Note: For key and references 1 to 17, see pages 3/68 and 3/69.
Different types of cable are available, making it possible to create any type of
application, including for harsh environments (for a denition of standard and harsh
environments, see page 3/68).
Several connectors are available to meet any requirement: straight or 90° angled
connectors, or angled connectors with the option of connecting a PC or diagnostic
pocket PC.
Power can be supplied to devices by means of cables, cordsets and tap junctions:
one AWG24 pair for the CAN signals, one AWG22 pair for the power supply and
the ground.
In addition to the IP 20 cabling offer, there is also an IP 67 cabling offer.
1
2
3
4
5
6
7
8
9
10
3/68
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
CANopen machine and installation bus
Cabling systems
Standard tap junctions and connectors
Designation Description No.
(1)
Reference Weight
kg
IP 20 CANopen tap
junction
4 SUB-D ports. Screw terminal block for
connecting the trunk cables
Line termination
1TSXCANTDM4 0.196
IP 20 connectors
CANopen female
9-way SUB-D.
Switch for line
termination
90° angled 2TSXCANKCDF90T 0.046
Straight (2) TSXCANKCDF180T 0.049
Right angle with 9-way SUB-D for connecting a
PC or diagnostic tool
4TSXCANKCDF90TP 0.051
IP 67 M12 connectors Male FTXCN12M5 0.050
Female FTXCN12F5 0.050
IP 20 CANopen tap
junctions for Altivar
and Lexium 32
2 RJ45 ports 9VW3CANTAP2
IP 20 standard cables and preformed cordsets
Designation Description No.
(1)
Length Unit
reference
Weight
kg
CANopen cables
(AWG 24)
Standard, e marking: low smoke emission. Zero
halogen. Flame-retardant (IEC 60332-1)
550 m TSXCANCA50 4.930
100 m TSXCANCA100 8.800
300 m TSXCANCA300 24.560
Standard, UL certication, e marking:
ame-retardant (IEC 60332-2)
550 m TSXCANCB50 3.580
100 m TSXCANCB100 7.840
300 m TSXCANCB300 21.870
For harsh environments (3) or mobile
installations, e marking: low smoke emission.
Zero halogen. Flame-retardant (IEC 60332-1).
Oil-resistant
550 m TSXCANCD50 3.510
100 m TSXCANCD100 7.770
300 m TSXCANCD300 21.700
CANopen preformed
cordsets
One 9-way female
SUB-D connector at
each end
(AWG 24)
Standard, e marking: low smoke emission.
Zero halogen. Flame-retardant (IEC 60332-1)
6a 0.3 m TSXCANCADD03 0.091
1 m TSXCANCADD1 0.143
3 m TSXCANCADD3 0.295
5 m TSXCANCADD5 0.440
Standard, UL certication, e marking:
ame-retardant (IEC 60332-2)
6a 0.3 m TSXCANCBDD03 0.086
1 m TSXCANCBDD1 0.131
3 m TSXCANCBDD3 0.268
5 m TSXCANCBDD5 0.400
CANopen preformed
cordsets
One 9-way SUB-D connector,
One RJ45 connector
(AWG 24)
6b 0.5 m TCSCCN4F3M05T
1 m TCSCCN4F3M1T
VW3M3805R010(4)
3 m TCSCCN4F3M3T
Two 9-way SUB-D connectors, one male and
one female
0.5 m TLACDCBA005
1.5 m TLACDCBA015
3 m TLACDCBA030
5 m TLACDCBA050
IP 67 standard preformed cordsets
Designation Description No.
(1)
Length Unit
reference
Weight
kg
CANopen preformed
cordsets
Preformed cordsets of two 5-way M12 A-coded
angled connectors (one male connector and one
female connector)
12 0.3 m FTXCN3203 0.40
0.6 m FTXCN3206 0.70
1 m FTXCN3210 0.100
2 m FTXCN3220 0.160
3 m FTXCN3230 0.220
5 m FTXCN3250 0.430
(1) For key to numbers, see page 3/67.
(2) For connection to Controller Inside programmable card, the VW3CANKCDF180T connector can also be used.
(3) Standard environment:
- Without any particular environmental constraints-
- Operating temperature between + 5°C and + 60°C-
- Mounted installation-
Harsh environment:
- Resistance to hydrocarbons, industrial oils, detergents, solder splashes-
- Relative humidity up to 100%-
- Saline atmosphere-
- Signicant temperature variations-
- Operating temperature between - 10°C and + 70°C-
- Mobile installation-
(4) Cordset with line termination.
TSXCANKCDF90T
TSXCANKCDF180T
TSXCANKCDF90TP
TSXCANTDM4
VW3CANTAP2
References
1
2
3
4
5
6
7
8
9
10
3/69
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
CANopen machine and installation bus
Cabling systems
IP 20 connection accessories
Designation Description No.
(1)
Length Reference Weight
kg
CANopen
connector
for Altivar 71
drive (2)
9-way female SUB-D. Switch for line termination.
Cables exit at 180°
VW3CANKCDF180T
Adaptor for Altivar 71
drive
SUB-D to RJ45 CANopen adaptor VW3CANA71
Preformed CANopen
cordsets for Altivar
drives
One RJ45 connector at each end 10 0.3 m VW3CANCARR03
1 m VW3CANCARR1
Y-connector CANopen/Modbus TCSCTN011M11F
IP 67 connection accessories
For Modicon FTB monobloc splitter boxes
Designation Composition No.
(1)
Length
m
Reference Weight
kg
IP 67 line terminator Equipped with one M12 connector
(for end of bus)
13 FTXCNTL12 0.010
24 V c power supply
connection cables
Equipped with two 5-way 7/8 connectors 16 0.6 FTXDP2206 0.150
1 FTXDP2210 0.190
2 FTXDP2220 0.310
5 FTXDP2250 0.750
Equipped with one 5-way 7/8 connector at one
end and ying leads at the other end
17 1.5 FTXDP2115 0.240
3 FTXDP2130 0.430
5 FTXDP2150 0.700
T-connector
for power supply
Equipped with two 5-way 7/8 connectors FTXCNCT1 0.100
Separate parts
Designation Composition Sold in
lots of
Reference Weight
kg
Connectors 7/8 type, 5-way Male FTXC78M5 0.050
Female – FTXC78F5 0.050
Straight, M12 type, 5 screw terminals Male XZCC12MDM50B 0.020
Female – XZCC12FDM50B 0.020
Angled, M12 type, 5 screw terminals Male XZCC12MCM50B 0.020
Female – XZCC12FCM50B 0.020
Sealing plugs For M8 connector (sold in packs of 10) FTXCM08B 0.100
For M12 connector
(sold in packs of 10)
FTXCM12B 0.100
For 7/8 connector FTXC78B 0.020
Y-connectors Connection of two M8 connectors to M12 connector on
splitter box
FTXCY1208 0.020
Connection of two M12 connectors to M12 connector on
splitter box
FTXCY1212 0.030
Diagnostics adaptor Equipped with two M12 connectors FTXDG12 0.020
Marker labels For plastic splitter boxes 10 FTXBLA10 0.010
For metal splitter boxes 10 FTXMLA10 0.010
(1) For key to numbers, see page 3/67.
(2) For ATV71HpppM3, ATV71HD11M3X, HD15M3X, ATV71H075N4 to HD18N4 drives, this
connector can be replaced by the TSXCANKCDF180T connector.
References (continued)
FTXDP21pp
FTXCY1208
VW3CANA71
XZCC12pDM50B
XZCC12pCM50B
1
2
3
4
5
6
7
8
9
10
3/70
Modicon M340
automation platform
BMXEIA0100 master module for AS-Interface
cabling system
Introduction
The BMXEIA0100 master module for AS-Interface cabling system provides the
AS-Interface system master function for the Modicon M340 automation platform.
The AS-Interface cabling system consists of a master station (Modicon M340
platform) and slave stations. The master supporting the AS-Interface prole
interrogates the devices connected on the AS-Interface line one by one and stores
the information (actuator/sensor status, device operating status) in the PAC memory.
Communication on the AS-Interface line is managed transparently in relation to the
application PAC program.
The BMXEIA0100 master module supports the latest management prole for
AS-Interface devices (AS-Interface V3) that are able to manage level V1, V2 and V3
AS-Interface slaves:
Discrete slave devices (up to 62 devices of 4I/4Q organized in 2 banks (A/B) of
b
31 addresses each)
Analog devices (up to 31 devices (4 channels) in bank A)
b
Safety interfaces (up to 31 devices in bank A)
b
An AS-Interface power supply is required for powering the various devices on the line.
Ideally it should be placed near stations that consume a great deal of energy. Please
refer to the “Phaseo power supplies and transformers - AS-Interface range” catalog.
A Modicon M340 Performance conguration with BMXP3420p0/20p02 processor
can take 4 BMXEIA0100 modules. A Standard conguration with BMXP341000
processor can take 2 BMXEIA0100 modules.
Description
The BMXEIA0100 AS-Interface master module is standard format (1 slot). Its
housing provides IP 20 protection of the electronics and it is locked into each rack
slot 01 to 11) by a captive screw.
The BMXEIA0100 AS-Interface master module features:
1 Rigid body providing support and protection for the electronic card.
2 Module reference marking.
3 Display block with 5 LEDs indicating the module operating modes:
RUN (green): Module running v
ERR (red): Module fault detected v
A/B (green): Displays the group of 31 slaves v
I/O (red): I/O fault detected on AS-Interface line v
32 LEDs for diagnostics of the AS-Interface line and each slave connected on v
the line depending on the A/B push button selection (1).
4 2 LEDs marked ASI POWER and FAULT: AS-Interface external power supply
present and AS-Interface line fault: see diagnostics on page 3/71.
5 Two pushbuttons marked A/B and MODE: see diagnostics on page 3/71.
6 3-way male SUB-D connector for the AS-Interface cable (female screw
connector supplied).
___________________________________________________________________________
(1) Depending on whether A or B is selected, this displays either the rst 31 slaves (standard
addressing) or the last 31 slaves (extended addressing).
1
3
5
2
4
BMXEIA0100
Introduction,
description
4
XAL control station
Safety
interface
XVB illuminated
indicator bank
Motor starter Phaseo
AS-Interface
power supply
Sensors via
Advantys interface
AS-Interface
6
Modicon M340 PAC
T
1
2
3
4
5
6
7
8
9
10
3/71
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
BMXEIA0100 master module for AS-Interface
cabling system
Diagnostics
BMXEIA0100 module
The two LEDs 4 on the module front panel are used in conjunction with the two
pushbuttons 5 for module diagnostics:
LEDs Pushbuttons
4 ASI PWR:
AS-Interface
power supply present
4 FAULT: AS-Interface
line fault
5 A/B: Selects the
group of slaves on the
display block 3
5 MODE: Module
Ofine/Online
The display block on the front panel of the BMXEIA0100 master module can be used
to perform simplied local diagnostics by displaying the slave devices present on the
AS-Interface line.
Detailed diagnostics of each of the slave devices is also possible using:
The
b ASITERV2 adjustment terminal
A web browser using the Rack Viewer function in the standard Web server on the
b
Modicon M340 platform (see page 3/14)
References
Description Usage Reference Weight
kg
AS-Interface
master module
supplied with 3-way male
SUB-D connector
M4 AS-Interface prole
for level V1, V2 and V3
slaves
BMXEIA0100
0.340
Adjustment terminal For addressing and diagnostics
of AS-Interface level
V1, V2 and V3 interfaces
Powered by LR6 batteries
ASITERV2
1.000
ASITERV2
Diagnostics,
references
1
2
3
4
5
6
7
8
9
10
3/72
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Modbus and Character mode serial links
Introduction
Modicon
M340
PAC
Magelis
XBT HMI
Preventa
XPS MC
safety PLC
Altivar
71
drive
Twido
PLC
Lexium
32 servo drive
LU9 GC3
Modbus
TCP
Third-party
Modbus
device
The Modbus serial link is used for master/slave architectures on the Modicon
M340 automation platform. It is necessary, however, to check that the Modbus
services used by the application have been implemented on relevant devices.
The bus consists of a master station and slave stations. Only the master station can
initiate the exchange (direct communication between slave stations is not possible).
Two exchange mechanisms are available:
Question/response, where requests from the master are addressed to a given slave.
b
The master then waits for the response from the slave that has been interrogated.
Broadcasting, where the master broadcasts a message to slave stations on the
b
bus. The slave stations execute the order without transmitting a reply.
The Modicon M340 platform offers two serial link connection options for Modbus or
Character mode:
Via the serial link integrated in the following processors:
b
Standard processor vBMXP341000
Performance processors vBMXP342000/20102/2020
Via the 2-channel serial link module
b BMXNOM0200.
Although both these types of serial link can support modems, the BMXNOM0200
module is particularly recommended for this type of use.
Its performance and numerous parameter options make it ideal for any type of
conguration, especially when using radio modems.
The number of serial link modules is limited by the maximum number of application-
specic channels permitted per station, depending on the type of processor:
Standard processor
b BMXP341000: maximum of 20 application-specic channels (1).
Performance processors
b BMXP342pppp: maximum of 36 application-specic
channels (1).
___________________________________________________________________________
(1) Application-specic channels: BMXEHC0200 counter modules (2 channels), BMXEHC0800
(8 channels), BMXMSP0200 motion control modules (2 channels), BMXNOM0200 serial link
module (2 channels) and BMXNOR0200H RTU communication module (1 channel).
Introduction
1
2
3
4
5
6
7
8
9
10
3/73
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Modbus and Character mode serial links
Description
Processors with integrated serial link
BMXP341000/2000/20102/2020 processors integrate a serial link that can be used
with either the Modbus RTU/ASCII master/slave protocol or with the Character
mode protocol.
These processors display the following elements on the front panel, relating to the
serial port:
1 Display block including at least the following LEDs:
SER COM LED (yellow): Activity on the serial link (lit) or detected fault on a v
device present on the serial link (ashing).
2 RJ45 connector for Modbus serial link or Character mode link (non-isolated RS
232C/RS 485) with its black indicator.
Note: For more information about the processors, see page 1/5.
BMXNOM0200 serial link module
The front panel of the BMXNOM0200 serial link module features:
1 Screw for locking the module in a slot in the rack.
2 Display block with 4 LEDs:
RUN (green) and ERR (red): Module status v
For each of the two channels: SER COM (green): Activity on the serial link (lit)/ v
detected fault on a device present on the serial link (ashing).
3 Two RJ45 connectors (exclusive use) for connection of channel 0 (with black
indicator):
3a v A connector for RS 232C connection, marked COM Port 0 RS232
3b v A connector for RS 485 connection, marked COM Port 0 RS485
4 RJ45 connector for RS 485 connection of channel 1, marked COM Port 1 RS485,
with black indicator.
To be ordered separately:
RS 485 cordsets (see page 3/76) or RS 232 cordsets for DCE terminal
(see page 3/75).
___________________________________________________________________________
(1) For isolated serial links, use the TWDXCAISO isolation box.
Description
BMXP3420102 BMXP341000/2000/2020
1
2
BMXNOM0200
2
3b
3a
4
1
1
2
3
4
5
6
7
8
9
10
3/74
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Modbus and Character mode serial links
Specications
Complementary specications
The following specications complement those indicated in the selection guide
on page 3/4.
Serial link integrated in the processors
Physical interface: b
In Modbus v: RS 232 4-wire or RS 485 2-wire, non-isolated (1)
In Character mode: RS 232 4-wire or RS 485 2-wire v
Frame:
b
In Modbus: RTU/ASCII half duplex v
In Character mode: full duplex in RS 232, half duplex in RS 485 v
Maximum length of a tap link in RS 485 2-wire: b
15 m in a non-isolated serial link v
40 m in an isolated serial link (1) v
BMXNOM0200 module serial links
Physical interface:
b
RS 232 port 0: RS 232 8-wire, non-isolated v
RS 485 port 0 and port 1: RS 485 2-wire, isolated v
Frame:
b
Modbus: RTU/ASCII, full duplex in RS 232, half duplex in RS 485 v
Character mode: full duplex in RS 232, half duplex in RS 485 v
Data rate:
b
RS 232 port 0: 0.3 to 115 Kbps (Modbus/Character mode) v
RS 485 port 0 and port 1: 0.3 to 57.6 Kbps (Modbus/Character mode) v
Line polarization:
b
Modbus RS 485: automatic v
RS 485 character mode: congurable with Unity v Pro software
Maximum length of a tap link in RS 485 2-wire: b
15 m in a non-isolated link v
40 m in an isolated link v
Expert mode (from version V1.2 of the module and version V5 of Unity Pro): used b
to congure the time out links individually from the application and thus adapt to the
specic specications of certain modems.
___________________________________________________________________________
(1) For isolated serial links, use the TWDXCAISO isolation box.
1
2
3
4
5
6
7
8
9
10
3/75
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
References
I/O capacity Memory
capacity
Integrated
communication ports
Reference Weight
kg
BMXP3410 Standard processor with integrated serial link, 2 racks
512 discrete I/O 128
analog I/O 20
application-specic
channels
2048 KB
integrated
Modbus serial link BMXP341000 0.200
BMXP3420 Performance processors with integrated serial link, 4 racks
1024 discrete I/O 256
analog I/O 36
application-specic
channels
4096 KB
integrated
Modbus serial link BMXP342000 0.200
Modbus serial link
CANopen bus
BMXP342010 0.210
Modbus serial link
CANopen bus
version V2.1 (1)
BMXP3420102 0.210
Modbus serial link
Ethernet Modbus/TCP
network
BMXP342020 0.205
Modbus serial link
Designation Protocol Physical layer Reference Weight
kg
Modbus serial link
2 channels (2)
Modbus
master/slave
RTU/ASCII,
Character
mode,
GSM/GPRS
modem
1 non-isolated RS 232
channel (Port 0)
2 isolated RS 485
channels (Port 0 and
Port 1)
BMXNOM0200 0.230
Cordsets for RS 232 serial link (3)
Designation Description Length Reference Weight
kg
Cordset for Data
Terminal Equipment
(DTE) (printer)
Equipped with an RJ45
connector and a 9-way
female SUB-D connector
3 m TCSMCN3M4F3C2 0.150
Cordset for Data
Communication
Equipment (DCE)
(modem, etc.)
Equipped with
an RJ45
connector and a
9-way male
SUB-D
connector
4-wire
(RX, TX,
RTS, CTS)
3 m TCSMCN3M4M3S2 0.150
8-wire
(excluding
RI signal)
3 m TCSXCN3M4F3S4 0.165
(1) Version that can be used to customize conguration of the device Boot Up procedure
compatible with third-party CANopen products. Requires Unity Pro version V4.1.
(2) For the ruggedized version, BMXNOM0200H, see specications on pages 6/2 and 6/8.
(3) RS 485 serial link connection (see pages 3/76 and 3/77).
BMXP341000/2000
BMXP342020
Modicon M340
automation platform
Modbus and Character mode serial links
References
BMXNOM0200
1
2
3
4
5
6
7
8
9
10
3/76
Extension and adaptation elements for RS 485 serial link
Designation Description No. Length Unit
reference
Weight
kg
Modbus splitter box 1 screw terminal block for trunk cable: -
D(A), D(B), t and 0V
8 x RJ45 connectors for tap-off-
2 x RJ45 connectors for series -
connection of LU9 GC3 splitter boxes
Mounting on 35 mm DIN rail
1LU9GC3 0.500
T-junction boxes
dedicated to Altivar and
Lexium
2 x RJ45 connectors-
1 integrated cable with RJ45 connector-
20.3 m VW3A8306TF03 0.190
1 m VW3A8306TF10 0.210
Passive T-junction box Tap-off and extension of the bus-
Line termination-
TSXSCA50
0.520
2-channel passive
subscriber socket
2 x 15-way female
SUB-D connectors and 2
screw terminal blocks
2-channel tap-off point and extension -
of trunk cable
Address coding-
Line termination-
3TSXSCA62 0.570
Junction box
Screw terminal block for
trunk cable tap-off
1 x RJ45 connector for
tap-off
Isolation of the RS 485 serial link-
Line termination -
(R = 120 , C = 1 nF)
Line pre-polarization - (1)
(2 R = 620 )
24 V c power supply (2)
Mounting on 35 mm DIN rail
4TWDXCAISO 0.100
Tap junction
3 x RJ45 connectors
Line termination -
(R =120 , C = 1 nF)
Line pre-polarization - (1)
(2 R = 620 )
Mounting on 35 mm DIN rail
TWDXCAT3RJ 0.080
Modbus/Bluetooth®
adaptor
1 Bluetooth- ® adaptor (range 10 m,
class 2) with 1 x RJ45 connector
1 x0.1 m long cordset for PowerSuite -
with 2 x RJ45 connectors
1 x0.1 m long cordset for TwidoSuite, -
with 1 x RJ45 connector and 1 mini-DIN
connector
1 RJ45/9-way male SUB-D adaptor -
for Altivar drives
VW3A8114 0.155
RS 232C/RS 485 line
converter without
modem signals
24 V c/20 mA power supply, 19.2
Kbps
Mounting on 35 mm DIN rail
5XGSZ24 0.100
Line terminator For RJ45 connector
R = 120 , C = 1 nF
12 Sold in
packs of 2
VW3A8306RC 0.200
(1) Line polarization required for connection to the master Twido programmable controller.
(2) 24 V c power supply, or power supply via the serial port integrated in Modicon M340 processors.
Modicon M340
automation platform
Modbus and Character mode serial link
Cabling systems
Connections,
references
1
7
8
7
4
3
9
5
212
10
12
RS 232
RS 485
11
6
7
9
24 V c
Magelis
XBT HMI Modicon
Premium
PACModicon
Quantum
PACAltivar
31 drive
Modbus
RS 232 TCP
Modbus
TCP
Modicon
OTB
Preventa
XPS MC safety PLC
Twido
PLC
Lexium
32
servo drive
Altivar
71 drive
Modicon
M340
PAC
In
Out
Third-party
Modbus device
LU9GC3
TSXSCA50
TSXSCA62
XGSZ24
TWDXCAISO TWDXCAT3RJ
VW3A8306TFpp
VW3A8114
1
2
3
4
5
6
7
8
9
10
3/77
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Software:
page 4/2 Ruggedized Modicon M340 modules:
page 6/2
Modicon M340
automation platform
Modbus and Character mode serial link
Cabling systems
Cables and cordsets for RS 485 serial link
Designation Description No. Length Unit
reference
Weight
kg
RS 485 double
shielded twisted pair
trunk cables
Modbus serial link, supplied without
connector
6100 m TSXCSA100 5.680
200 m TSXCSA200 10.920
500 m TSXCSA500 30.000
Modbus RS 485
cordsets
2 x RJ45 connectors 70.3 m VW3A8306R03 0.030
1 m VW3A8306R10 0.050
3 m VW3A8306R30 0.150
1 x RJ45 connector and 1 x 15-way
SUB-D connector
3 m VW3A8306 0.150
1 x mini-DIN connector for Twido
controller and 1 x RJ45 connector
80.3 m TWDXCARJ003 0.040
1 m TWDXCARJ010 0.090
3 m TWDXCARJ030 0.160
1 x RJ45 connector and
1 end with ying leads
93 m VW3A8306D30 0.150
1 miniature connector and 1 x 15-way
SUB-D connector
10 3 m TSXSCPCM4530 0.180
Cordsets for Magelis
XBT display units and
terminals
1 x RJ45 connector and 1 x 25-way
SUB-D connector for:
XBTN200/N400/NU400-
XBTR410/411-
XBTGT2 to GT7 (COM1 port) - (1)
11 2.5 m XBTZ938 0.210
2 x RJ45 connectors for:
XBTGT1- (COM1 port)
XBTGT2 to GT7 (COM2 port)-
11 3 m VW3A8306R30 0.150
Cordsets for RS 232 serial link
Designation Description Length Reference Weight
kg
Cordset for
Data Terminal
Equipment (DTE)
(printer)
Serial link for DTE (2)
1 x RJ45 connector and 1 x 9-way female SUB-D
connector
3 m TCSMCN3M4F3C2 0.150
Cordset for
Data Communication
Equipment (DCE)
(modem, converter)
Serial link for DCE
1 x RJ45 connector and 1 x 9-way male SUB-D
connector
3 m TCSMCN3M4M3S2 0.150
(1) For use with XBTZG909 adaptor.
References (continued)
1
2
3
4
5
6
7
8
9
10
3/78
1
2
3
4
5
6
7
8
9
10
4/1
4.1 - Unity Pro software
Selection guide ..................................................4/2
Introduction
b ....................................................4/4
FDT/DTM functions
b ..............................................4/4
Functions
b ......................................................4/6
Unity Pro XLS specic functions (SIL3 Modicon
b Quantum) .............4/14
Communication drivers, Unity Developer’s Edition
b .....................4/18
Windows
b® OS compatibility .......................................4/19
Unity Pro update
b ...............................................4/19
References
b ...................................................4/20
4.2 - RTU conguration software
Introduction, setup, variables
b ......................................4/24
References
b ...................................................4/25
4.3 - Unity EFB Toolkit software
Introduction, setup
b ..............................................4/26
References
b ...................................................4/27
4.4 - Unity DIF software
Introduction, setup
b ..............................................4/28
References
b ...................................................4/29
4.5 - Unity Loader software and libraries
Introduction
b ...................................................4/30
References
b ...................................................4/31
4.6 - Unity Application Generator software
Introduction, applications
b .........................................4/32
References
b ...................................................4/33
4.7 - Supervisory control and data acquisition
software (SCADA): Vijeo Citect
Introduction
b ...................................................4/34
Architectures
b ..................................................4/36
References
b ...................................................4/38
4.8 - Vijeo Historian reporting software
Introduction
b ...................................................4/48
References
b ...................................................4/50
4.9 - OPC data server software
Introduction
b ...................................................4/52
Setup
b. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4/55
Functions
b .....................................................4/56
References
b ...................................................4/57
Programmable process control ............... see page 2/24
MFB motion control ............................. see page 2/34
Software
Contents chapter 4
1
2
3
4
5
6
7
8
9
10
4/2
Modicon M340
automation platform
Unity Pro software
Unity Pro programming software for Modicon M340 M, Premium P, Quantum Q and SIL3 Quantum S and for Modicon distributed I/O D
IEC 61131-3
languages
Instruction List (IL) M - D M - P - D
Ladder (LD) M - D M - P - D
Structured Text (ST) M - D M - P - D
Function Block Diagram (FBD) M - D M - P - D
Sequential Function Chart (SFC)/Grafcet M - D M - P - D
Programming
services
Multitask programming (Master, fast and
event-triggered)
M - D M - P - D
Multitask programming (Master, fast,
auxiliary and event-triggered)
Functional view and function modules M - D M - P - D
DFB editor and instances M - D M - P - D
DDT compound data editor M - D M - P - D
Data structure instances and tables M - D M - P - D
EF libraries and EFBs M - D M - P - D
User-denable control loops P (TSXP572p) - D
Programmable control loops (with process
control function block library)
M - D M - P - D
Safety function block libraries
Motion function block (MFB) libraries M - D M - P - D
Hot Standby PAC redundancy system P (TSXH5724M) - D
System diagnostics M - D M - P - D
Application diagnostics M - D M - P - D
Diagnostics with location of detected error M - D M - P - D
Bus and network conguration to slave
devices (Modicon distributed I/O, etc)
M - D M - P - D
Debugging and
display
services
PAC simulator M - D M - P - D
Hypertext link animations in graphic
languages
M - D M - P - D
Step by step execution, breakpoint M - D M - P - D
Watchpoint M - D M - P - D
Runtime screens M - D M - P - D
Diagnostic viewer M - D M - P - D
Other services Creation of hyperlinks M - D M - P - D
XML import/export M - D M - P - D
Application converters (Concept, PL7) M - P - D
Utilities for updating PAC operating systems
and Advantys
M - D M - P - D
Communication drivers for
Windows 2000/XP
M - D M - P - D
Unity Pro servers - Openness
UDE support
OFS exchanges
Dynamic exchange with 3rd party tools,
OFS
Static exchange via XML/XVM export les M - D M - P - D
Compatible
Modicon
platforms
Modicon M340 processors MBMXP341000
BMXP3420p0/20p02
BMXP341000
BMXP3420p0/20p02
Premium CPUs P– TSXP57Cp0244/0244M
TSXP57104/1634/154M
TSXP57204/2634/254M
TSXH5724M
Quantum CPUs Q– –
SIL3 Quantum CPUs S– –
Compatible Modicon distributed I/O D STB, OTB, FTB, FTM, ETB, MomentumSTB, OTB, FTB, FTM, ETB, Momentum
Software name Unity Pro Small Unity Pro Medium
Unity Pro software type UNYSPUSFpCD50 UNYSPUMFpCD50
Page 4/20 4/21
Selection guide
1
2
3
4
5
6
7
8
9
10
4/3
Unity Pro programming software for Modicon M340 M , Premium P , Quantum Q and SIL3 Quantum S and for Modicon distributed I/O D
M - P - Q - D M - P - Q - D M - P - Q - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - D
M - P - Q - D M - P - Q - D M - P - Q - D
P (TSXP575p) - Q (140CPU651/671) - D P (TSXP575p) - Q (140CPU651/671)- D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - D
M - P - Q - D M - P - Q - D M - P - Q - D
M - P - Q - D M - P - Q - D M - P - Q - D
M - P - Q - D M - P - Q - D M - P - Q - D
P (TSXP572p/3p/4p) - D P (TSXP572p/3p/4p/5p) - D P (TSXP572p/3p/4p/5p)- D
M - P - Q - D M - P - Q - D M - P - Q - D
S - D
M - P - D M - P - D M - P - D
P (TSXH5724/44M) - D P (TSXH5724/44M) - Q (140CPU67 160) - D P (TSXH5724/44M) - Q (140CPU67 160) - S - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - D
M - P - Q - D M - P - Q - D M - P - Q - D
M - P - Q - D M - P - Q - D M - P - Q - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - D
M - P - Q - D M - P - Q - D M - P - Q - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - S - D
M - P - Q - D M - P - Q - D M - P - Q - S - D
BMXP341000
BMXP3420p0/20p02
BMXP341000
BMXP3420p0/20p02
BMXP341000
BMXP3420p0/20p02
TSXP57Cp0244/0244M
TSXP57104/1634/154M
TSXP57204/2634/254M
TSXP57304/3634/354M
TSXP574634/454M
TSXH5724/44M
TSXP57Cp0244/0244M
TSXP57104/1634/154M
TSXP57204/2634/254M
TSXP57304/3634/354M
TSXP574634/454M
TSXP575634/554M
TSXP576634M
TSXH5724/44M
TSXP57Cp0244/0244M
TSXP57104/1634/154M
TSXP57204/2634/254M
TSXP57304/3634/354M
TSXP574634/454M
TSXP575634/554M
TSXP576634M
TSXH5724/44M
140CPU31110
140CPU43412U
140CPU53414U
140CPU31110
140CPU43412U
140CPU53414U
140CPU65150/60
140CPU65260
140CPU67160
140CPU31110
140CPU43412U
140CPU53414U
140CPU65150/60
140CPU65260
140CPU67160
– – 140CPU65160S
140CPU67160S
STB, OTB, FTB, FTM, ETB, Momentum STB, OTB, FTB, FTM, ETB, Momentum STB, OTB, FTB, FTM, ETB, Momentum
Unity Pro Large Unity Pro Extra Large Unity Pro XLS
UNYSPULFpCD50 UNYSPUEFpCD50 UNYSPUXFpCD41
4/21 4/22 4/22
1
2
3
4
5
6
7
8
9
10
4/4
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
Introduction,
functions
Introduction
Unity Pro is the common programming, debugging and operating software for the
Modicon M340, Premium and Quantum PAC automation platforms.
Unity Pro is multitasking software offering the following features:
Five IEC 61131-3 programming languages b
Integrated, customizable DFB library b
PAC simulator on PC for program validation prior to installation b
Built-in tests and diagnostics b
Wide range of online services b
FDT/DTM functions
Unity Pro facilitates integration of eldbus architectures into engineering control
systems using FDT/DTM technology:
FDT b(Field Device Tool) is the container that supports the device DTMs.
DTM b(Device Type Manager) is the conguration tool for devices with integrated
graphical interfaces. It contains the properties specic to each device.
In addition to the FDT/DTM standard, Unity Pro uses specic information from the
Master DTM created for the Probus Remote Master (PRM) module and the
Modbus/TCP and Ethernet/IP network module BMXNOC0401.
Use of the Master DTM allows Unity Pro to perform the following actions:
Manage the PAC I/O scan b
Create the application variables based on the description of the process objects b
available from the connected DTM devices
Manage synchronization with the PAC conguration b
Create a generic DTM from the description les (GDS or EDS) b
The DTM conguration is stored in the PAC memory so that the application can be
downloaded in its entirety. It is also saved in the PAC project le (STU) and the
archive le (STA).
A third-party DTM can be installed in the DTM hardware catalog.
The DTM hardware catalog can be used to sort or lter the DTMs according to
various criteria such as Device, Vendor, Groups or Protocols.
The DTM Browser in Unity Pro:
Displays the eldbus topologies in a tree structure b
Allows the user to congure the DTM devices: b
Add and delete DTMs v
Connect and disconnect DTMs to/from their physical devices v
Display and print the properties of a DTM v
Transfer DTM conguration data to and from the physical device v
Functions specic to the DTM, via the Device menu v
Unity Pro
DTM editor (Modicon STB island)
DTM hardware catalog
DTM Browser and DTM context menu
1
2
3
4
5
6
7
8
9
10
4/5
Selection guide:
page 4/2
FDT/DTM function (continued)
The eldbus discovery function scans the physical devices in a eldbus network and
adds the selected devices to the DTM Browser.
The ve IEC languages
The ve graphical or textual languages available in Unity Pro are used for
programming Modicon M340, Premium and Quantum automation platforms.
The three graphical languages are:
Ladder (LD)
b
Function Block Diagram (FBD)
b
Sequential Function Chart (SFC) or Grafcet
b
The two textual languages are:
Structured Text (ST)
b
Instruction List (IL)
b
For these ve languages, you can use the standard set of instructions compliant with
IEC standard 61131-3 to create applications that can be transferred from one
platform to another. Unity Pro software also provides extensions to this standard set
of instructions. As they are specic to Modicon M340, Premium and Quantum PACs,
these extensions support the development of more complex applications to
maximize the potential of the specic features of each of these platforms.
Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
Functions (continued)
Fieldbus discovery screen
1
2
3
4
5
6
7
8
9
10
4/6
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
Data Editor
The data editor that can be accessed from the structural view of the project provides
a single tool for performing the following editing tasks:
Declaration of data including variables and function blocks (declaration of their
b
type, instance and attributes)
Use and archiving of function block data types in different libraries
b
Hierarchical view of data structures
b
Searching, sorting, and ltering of data
b
Creation of a hyperlink to access a description from any variable comment
b
The data is displayed under four tabs:
“Variables” for the creation and management of the following data instances: bits,
b
words, double words, inputs/outputs, tables and structures
“DDT Types” for the creation of derived data types (tables and structures)
b
“Function Blocks” for the declaration of EFBs and DFBs
b
“DFB Types” for the creation of DFB data types
b
Each data element has several attributes, of which:
The variable name and type are mandatory
b
The comment, physical address in the memory and initial values are optional
b
The data editor columns can be congured (number of columns, order). The
attributes associated with a variable can be displayed in a properties window.
This editor can be accessed at any time during programming by selecting variables
for data modication or creation.
Functions (continued)
Data Editor
Data Properties
1
2
3
4
5
6
7
8
9
10
4/7
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
DFB user function blocks
Using Unity Pro software, users can create their own function blocks for specic
application requirements on Modicon M340, Premium and Quantum PAC
automation platforms.
Once created and saved in the library, these user function blocks can be reused as
easily as EFBs (Elementary Function Blocks).
These user function blocks are used to structure an application. They are used when
a program sequence is repeated several times in the application or for correcting a
standard programming routine. They can be read-only or read/write. They can be
exported to other Unity Pro applications.
Using a DFB in one or more applications:
Simplies program design and entry
b
Improves program readability and understanding
b
Facilitates program debugging (variables handled by the DFB are identied in the
b
data editor)
Enables the use of private variables specic to the DFBs that are independent of
b
the application
A DFB is set up in several stages:
The DFB is designed by assigning a name, a set of parameters (inputs, outputs,
b
public and private internal variables) and a comment to it via the data editor.
The code is created in one or more sections of the program, with the following
b
languages selected according to requirements: Structured Text, Instruction List,
Ladder or Function Block Diagram (ST, IL, LD or FBD).
The DFB may be stored in a library with an associated version number.
b
A DFB instance is created in the data editor or when the function is called in the
b
program editor.
This instance is used in the program in the same way as an EFB (Elementary
b
Function Block). The instance can be created from within the program.
Functions (continued)
Design
Creating the code
Use within the program
1
2
3
4
5
6
7
8
9
10
4/8
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
Function block libraries
The function and function block libraries manager contains the elements provided
with Unity Pro software. The functions and function blocks are organized into
libraries that consist of families. Depending on the type of PAC selected and the
processor model, users will have a sub-set of these libraries available to write their
applications. However, the “Base Lib” library contains a set of functions and function
blocks, the majority of which are compatible with any Modicon PAC. In particular, it
contains the blocks compliant with IEC 61131-3.
The “Base Lib” library is structured into families:
Timers and counters
b
Process control on integers
b
Table management
b
Comparison
b
Date and time management
b
Logic processing
b
Mathematical processing
b
Statistical processing
b
Character string processing
b
Type-to-type data conversion
b
The “Base Lib” library that covers standard automation functions, is supplemented
by other, more application-specic libraries and platform-specic functions:
Communication library
b . Provides an easy means of integrating communication
programs from PACs with those used by HMIs from the PAC application program.
Like other function blocks, these EFBs can be used in any language to exchange
data among PACs or to deliver data to be displayed on an HMI.
Process control library
b . The CONT_CTL library can be used to set up process-
specic control loops. It offers controller, derivative and integral control functions
plus additional algorithms, such as EFBs for calculating mean values, selecting a
maximum value, detecting edges or assigning a hysteresis to process values, etc.
Diagnostics library
b . Can be used to monitor actuators and contains EFBs for
active diagnostics, reactive diagnostics, interlocking diagnostics, permanent process
condition diagnostics, dynamic diagnostics, monitoring of signal groups, etc.
I/O management library
b . Provides services to handle information exchanged
with hardware modules (data formatting, scaling, etc.)
Motion Function Blocks library
b . Contains a set of predened functions and
structures to manage motion controlled by drives and servo drives connected on
CANopen.
Motion library.
b Provides motion control and fast counting.
System library
b . Provides EFBs for the execution of system functions, including
evaluation of scan time, availability of several different system clocks, SFC section
monitoring, display of system state, management of les on the memory cartridge of
the Modicon M340 processor, etc.
Finally, a library named “obsolete” containing function blocks used by legacy
b
programming software needed to perform application conversions.
Management of user standards
Users may create libraries and families to store their own DFBs and DDTs. This
enhancement allows users to take advantage of programming standards adapted to
their needs, along with version management. This means that it is possible to:
Check the version of the elements used in an application program against those
b
stored in the library
Perform an upgrade, if necessary
b
Functions (continued)
Standard function block libraries
User libraries
1
2
3
4
5
6
7
8
9
10
4/9
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
Debugging tools
Unity Pro software offers a complete set of tools for debugging Modicon M340,
Premium or Quantum applications. A tool palette provides direct access to the
main functions:
Dynamic program animation
b
Conguration of watchpoints or breakpoints (not authorized in event-triggered
b
tasks)
Step-by-step program execution. A function in this mode enables section-by-
b
section execution. Instruction-by-instruction execution can be launched from the
previous breakpoint. Three execution commands are therefore possible when the
element to be processed is a subroutine (SR) or DFB user block instance:
Step Into: This command is used to move to the rst element of the SR or DFB. v
Step Over: This command is used to execute the entire SR or DFB. v
Step Out: This command is used to move to the next instruction after the SR or v
DFB element.
Independent execution of the master (MAST), fast (FAST), auxiliary (AUX) and
b
event (EVTi) tasks
Animation of program elements
Dynamic animation is managed section by section. A button on the toolbar is used to
activate or deactivate animation for each section.
When the PAC is in RUN, this mode can be used to view, simultaneously:
The animation of a program section, regardless of the language used
b
The variables window containing the application objects created automatically
b
from the section viewed
Animation table
Tables containing the application variables to be monitored or modied can be
created by data entry or automatically initialized from the selected program section.
These tables can be stored in the application and retrieved from there at a later date.
Debugging DFB user function blocks
The parameters and public variables of these blocks are displayed and animated in
real time using animation tables, with the possibility of modifying and forcing the
required objects.
In exactly the same way as with other program elements, the watchpoint, breakpoint,
step-by-step execution and program code diagnostics functions can be used to
analyze the behavior of DFBs. Conguring a breakpoint in a DFB user function block
instance stops the execution of the task containing this block.
Debugging in Sequential Function Chart (SFC) language
The various debugging tools are also available in SFC language. However, unlike
other sections (IL, ST, LD, or FBD) an SFC section executed step-by-step does not
stop execution of the task but instead freezes the SFC chart. Several breakpoints
can be declared simultaneously within a single SFC section.
Functions (continued)
Dynamic animation/adjustment
Watchpoint
Breakpoints/step-by-step
1
2
3
4
5
6
7
8
9
10
4/10
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
PAC simulator
Unity Pro's integrated simulator can be used to test the application program for
Modicon M340, Premium or Quantum PACs from the PC terminal without
having to connect to the PAC processor. The functions provided by the debugging
tools are available for debugging the master, fast, and auxiliary tasks.
Because the simulator does not manage the PAC I/O, animation tables can be used
to simulate the state of inputs by forcing them to 0 or 1.
The simulator can be connected to third-party applications via an OPC server with
OFS (OPC Factory Server) software.
Documentation editor
The documentation editor is based on the Documentation Browser that shows the
le structure in tree form.
It allows the application le or a portion of the le to be printed on any graphics
printer accessible under Windows and using True Type technology, in A4 or US letter
print format.
The documentation editor supports the creation of user-specic les using the
following headings:
Title page
b
Contents
b
General information
b
Footer
b
Conguration
b
EF, EFB and DFB type function blocks
b
User variables
b
Communication
b
Project structure
b
Program
b
Animation tables and cross references
b
Runtime screens
b
Functions (continued)
Simulator control panel
Accessing the documentation editor
1
2
3
4
5
6
7
8
9
10
4/11
Diagnostics integrated into Modicon M340, Premium and Quantum automation platforms
Introduction
The diagnostics offer for Modicon M340, Premium and Quantum platforms is based
on the following three components:
System diagnostics
b
DFB and EFB diagnostic function blocks (for system and application diagnostics)
b
Error message display system, called viewers, supplied as a standard component
b
of Magelis XBT terminals, Vijeo Citect supervisory software and Unity Pro
setup software
System diagnostics
The system diagnostics for Modicon M340, Premium and Quantum automation
platforms support the monitoring of system bits/words, I/O modules and SFC step
activity times (minimum/maximum). By simply choosing the relevant option during
application conguration, any event will generate time-stamped messages logged in
the diagnostic buffer of the PAC.
These events are displayed automatically in a diagnostics viewer (1) without requiring
any additional programming.
With Unity Pro integrated diagnostics, this function can be used to perform rst level
diagnostics of the elements in the conguration, up to and including each I/O
module channel.
Conguration level
Viewer window (example with Unity Pro software)
Module level
Channel level
(1) Diagnostics viewers are tools for displaying and acknowledging diagnostic error messages.
They are supplied as a standard component of Unity Pro and Vijeo Designer software, with
Magelis terminals and with the PAC Web server that can be accessed via a Magelis iPC
thin client.
Processor for
system bits
and words
In-rack I/O
modules
Remote I/O
modules on
FIPIO
or CANopen
Higher-level
MES
Cell level
Machine level
Unity Pro software
Diagnostics viewersSystem diagnostics
Application diagnostics
Ethernet TCP/IP
Magelis XBT HMI
PC
Vijeo Citect software
Magelis iPC thin client
ModiconQuantum PAC,
Modicon Premium PAC,
Modicon M340 PAC
Vijeo Designer
software
Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
Integrated diagnostics
Functions (continued)
1
2
3
4
5
6
7
8
9
10
4/12
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
Modifying the program with the PAC in RUN mode
With Unity Pro, changes can be made to the program when the PAC connected to
the programming terminal is in RUN mode. These modications are performed with
the following operations:
The application contained in the PAC is transferred to the PC terminal running
b
Unity Pro, if necessary.
Program changes are prepared. These program modications can be of any type
b
and in any language (IL, ST, LD, FBD, and SFC), for example, addition or deletion of
SFC steps or actions. The code of a DFB user function block can also be modied
(however, modications of its interface are not permitted).
These program changes are updated in the PAC (in RUN mode).
b
This function makes it possible to add or modify program code and data in different
parts of the application in one single modication session (thus resulting in a unied,
consistent modication with respect to the controlled process). This increased
exibility comes at a cost in terms of the amount of program memory required.
Cross references function
Unity Pro's cross references function is available in standalone mode (ofine) and
when connected to the PAC in Run (online). It allows users to view the elements of a
PAC application when searching for any type of variable. This view indicates where
the declared variable is used, as well as how it is used (for writing, reading, etc.).
This function also accesses the Search/Replace function for variable names.
The variable search can be initialized from any editor (language, data, runtime
screen, animation table, etc.).
Import/export function
The import/export function available in Unity Pro supports the following operations
from the structural and functional project views:
Via the import function, reuse any portion of a project created previously
b
Via the export function, copying any portion of the current project to a le for
b
subsequent reuse
The les generated during export are generally in XML format (1). However, in
addition to XML, variables can be exported and imported in the following formats:
.xvm format compatible with OFS data server software
b
Source format, in an .scy le compatible with the PL7 design software
b
Text format with separator (TAB) in a .txt le for compatibility with any other system
b
During an import, a wizard can be used to reassign data to new instances of:
DFBs
b
DDTs
b
Simple data
b
In addition, when a functional module is imported, the data associated with
animation tables and runtime screens is also reassigned.
The XML import function also supports the transfer of a Modicon M340, Premium or
Quantum PAC conguration prepared in the SIS Pro costing and conguration tool
for use in the creation of a project in Unity Pro.
This import function spares the user from having to redene the PAC conguration
when the PAC has already been congured with the SIS Pro tool.
(1) XML language is an open, text-based language that provides structural and semantic
information.
Functions (continued)
Cross references table
Data export shortcut menu
Data import wizard
1
2
3
4
5
6
7
8
9
10
4/13
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
Application converters
Unity Pro's integrated conversion tools can be used to convert PAC applications
created with Concept and PL7 programming software to Unity Pro applications.
Concept/Unity Pro converter (Quantum PAC)
This conversion is performed with a Concept application V2.5 or later (it can also be
performed in V2.11 or later, but only after an update to V2.5). To perform the
conversion, export the application to an ASCII le in Concept.
The export le is converted to a Unity Pro source le automatically. This source le is
then analyzed by Unity Pro. At the end of the procedure, a conversion report is
generated and an output window displays any detected conversion errors and
provides direct access to the part of the program to be modied.
The Concept application converter converts the application to Unity Pro, but does
not guarantee that it will operate correctly in real time. It is the responsibility of the
user to test or debug converted applications.
PL7/Unity Pro converter (Premium PAC)
This conversion is performed with a PL7 application V4 or later (Premium slot-PAC).
To perform the conversion, the source le (complete application) or source le (user
function block) is exported in PL7.
The conversion procedure is similar to that of the Concept conversion described
above.
Note: Applications created with Concept, Modsoft and ProWORX can be converted to
LL984. Consult your Customer Care Center.
Functions (continued)
1
2
3
4
5
6
7
8
9
10
4/14
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
XLS
Functions (continued)
Unity Pro XLS
In addition to the functions of Unity Pro Extra Large, Unity Pro XLS provides a set of
specic check and protection function blocks to facilitate the creation and
debugging of SIL3 Quantum projects.
For a description of these specications and their setup, as well as the functional
limitations provided for within the framework of SIL3-certiable safety projects
according to IEC 61508, refer to the document entitled Quantum Safety PAC
Safety Reference Manual11/2007, No. 3303879.00, approved by TÜV Rheinland
and available at www.schneider-electric.com.
The Unity Pro XLS programming tool is certied compliant with the requirements of
IEC 61508 for the management of safety applications with Quantum 140CPU651
60S/67160S PACs.
It offers the complete range of functions required to program a safety project:
In-depth error diagnostics b
Project protection b
During project creation, it is the selection of the Quantum processor that determines
whether or not the project created will be a safety project.
Unity Pro XLS is capable of processing any Unity Pro application types.
No other programming tool is needed on the computer.
To program a safety project, Unity Pro XLS provides two IEC 61131-3 programming
languages:
Function Block Diagram (FBD) b
Ladder language (LD) b
Safety program structure
A safety project must be programmed entirely in a master task (MAST).
It is not possible to:
Program FAST, TIMER, INTERRUPT or AUX tasks b
Use subroutines (SR sections) b
Unity Pro
1
2
3
4
5
6
7
8
9
10
4/15
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
XLS
Functions (continued)
Unity Pro XLS (continued)
Language elements
Unity Pro XLS provides a set of specic, certied functions and function blocks.
These are available in the “Unity Pro safety function block library”.
Many of the language elements are available:
Elementary data types (EDTs): BOOL, EBOOL, BYTE, WORD, DWORD, INT, b
UINT, DINT, UDINT and TIME
Simple tables used exclusively for Ethernet Global Data communication b
Direct addressing, for example, writing to %MW memory via a coil b
in Ladder language (LD)
Located variables b
Project verication options
Unity Pro XLS provides the following different options for the checks performed by
the language analyser:
Unused variables b
Variables written multiple times b
Unassigned parameters b
FB instances used multiple times b
Address overlapping b
It is advisable to enable each available option when checking a safety project.
1
2
3
4
5
6
7
8
9
10
4/16
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
XLS
Unity Pro XLS (continued)
Project security
Unity Pro XLS provides security functions to help protect against unauthorized access
to safety projects, to the SIL3 Quantum PAC and to the Unity Pro XLS software.
The application password, dened when the safety project was created, is b
requested:
When the safety application le is opened v
Upon connection to the SIL3 Quantum PAC v
The safety editor integrated into Unity Pro XLS is used to dene the access b
permissions and the list of authorized functions for each user, in particular:
Creation and modication of the application password v
Activation of maintenance mode v
Adjustment of the auto-lock period b
Functions and function blocks for safety applications
Unity Pro XLS provides a set of elementary functions (EFs) and elementary function
blocks (EFBs) certied for use in safety applications:
Standard functions certied for safety applications: b
Mathematical functions and functions for manipulating data from the v
unrestricted memory area in the safety logic
Comparison functions v
Logic functions, rotations, shift operations v
Statistical functions v
Timer and counter setup v
Type conversions v
Specic functions for safety architectures: b
High availability setup: choice of two inputs from a redundant discrete I/O v
module or a redundant analog input module
Hot Standby PAC redundancy setup: to cause the two processors involved in a v
hot standby conguration to change roles from primary to standby and standby to
primary respectively. The objective is to verify the capacity of each processor to
take over in case the other processor becomes inoperative. With Unity Pro XLS,
this function can easily be programmed in the application by conguring the S_
HSBY_SWAP elementary function from the library.
Functions (continued)
1
2
3
4
5
6
7
8
9
10
4/17
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
XLS
Functions (continued)
Unity Pro XLS (continued)
Special features and procedures
Software tool self-test
Unity Pro XLS provides the option of running a self-test to verify that the software
components installed have not been corrupted, for example, due to a PC hard disk
failure. This self-test is based on a CRC calculation.
Unity Pro XLS checks the version and CRC of the following:
Its DLLs b
The safety FFB library database b
The hardware catalog database b
Unity Pro XLS self-tests are performed on a user request, for example:
After installing or uninstalling any program on the computer b
Before loading the nal application program into the PAC b
Before modifying the application program executed on the SIL3 Quantum PAC b
Time-stamping binary les
With Unity Pro XLS, every binary le generated for a safety project features a version
management eld that provides the date and time when it was generated.
This information is useful for checking the project.
Downloading a project to Unity Pro XLS
It is possible to upload a safety project from the PAC to Unity Pro XLS under the
following conditions:
This option was selected for the project. b
The user is required to know the application password to establish a connection to b
the SIL3 Quantum PAC.
The SIL3 Quantum PAC has been placed in maintenance mode to perform b
the upload.
Unrestricted memory
The unrestricted memory area contains bits and words that are not protected against
write operations from external equipment such as HMI terminals and PACs.
It is located at the beginning of the memory. b
Its size can be congured with Unity Pro XLS. b
Values cannot be used directly in the unrestricted memory area and can only be b
used in conjunction with specic function blocks S_MOVE_BIT and
S_MOVE_WORD.
Unity Pro XLS checks in both the application edit and generation phases to help
make sure that only data from the unrestricted memory area is used at the input of
the function blocks S_MOVE_BIT and S_MOVE_WORD.
Furthermore, Unity Pro XLS provides a useful list of cross references, allowing easy
identication of the way in which variables are used and verication of the application
of this rule.
Note: For safety applications, it is common practice to verify the correct transfer of data by writing
the data twice (to two different variables) and then comparing it.
1
2
3
4
5
6
7
8
9
10
4/18
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
Communication drivers
The drivers commonly used with the M340, Premium and Quantum platforms
are installed at the same time as the Unity Pro software.
Unity Pro also includes the following communication drivers that can be installed as
required (1):
Protocol - Hardware Windows XP
Professional
Windows Vista Business
32-bit Edition
Windows 7
32-bit and 64-bit Editions
Ethway - Ethernet
FIP - FPC10 ISA card
FIP - FPC20 PCMCIA card
FIP adaptor - CUSBFIP
ISAway - PCX57 ISA card
Modbus Serial - COM port
PCIway - Atrium TPCI57 PCI card
Uni-Telway - COM port
Uni-Telway - SCP114 PCMCIA card
USB for high end PAC
XWay on TCP/IP
Driver available Driver not available
Unity Developer's Edition, advanced open access
Advanced open access is helpful for experienced IT engineers. It support the
development of interfaces between Unity and expert tools and specic user-dened
functions.
This type of development requires experience in the following IT areas:
C++ or Visual Basic languages
b
Client/server architectures
b
XML and COM/DCOM technologies
b
Database synchronization
b
As a supplement to the Unity Pro Extra Large software (2), the UDE (Unity
Developer’s Edition) development kit UNYUDEVFUCD21E enables the
development of customized solutions. In addition to the development kit, the Unity
servers and accompanying documentation are also provided.
Unity Developer's Edition is compatible with:
Unity Pro Extra Large
b
Modicon M340 processors
b
Premium Unity processors
b
Quantum Unity processors
b
(1) Also available separately under reference TLXCDDRV20M
(2) Only the Unity Pro Extra Large version enables dynamic database management for data to
be exchanged with the OFS data server or a third-party tool.
Functions (continued)
1
2
3
4
5
6
7
8
9
10
4/19
Selection guide:
page 4/2
Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
Upgrade kits for Concept, PL7 Pro and ProWORX software
The Concept, PL7 Pro and ProWORX upgrade kits allow users who already have
one of these programs from the installed base and who have a current
subscription to obtain Unity Pro version V4.1 software at a reduced price.
These upgrades are only available for licenses of the same type (from Concept XL
group license to Unity Pro Extra Large group license).
Composition and Windows OS compatibility
Unity Pro multilingual software packages are compatible with Windows 2000
Professional and Windows XP operating systems.
They include:
Documentation in electronic format in six languages (English, German, Chinese,
b
Spanish, French and Italian)
Converters for converting applications created with Concept and PL7 Pro
b
programming software
PAC simulator
b
Cables for connecting the processor to the programming PC are ordered separately.
Unity Pro update
Customers are notied automatically when a new Unity Pro update
becomes available.
They can then access the software updates manager directly, download the
update, and install it on their workstation.
Functions (continued)
1
2
3
4
5
6
7
8
9
10
4/20
Selection guide:
page 4/2
References
Unity Pro Small, Medium, Large, Extra Large and XLS software packages
These software packages are for programming and conguring Unity automation
platforms. The software is available in ve versions:
Unity Pro Small b, see page 4/20
Unity Pro Medium, bsee page 4/21
Unity Pro Large b see page 4/21
Unity Pro Extra Large b see page 4/22
Unity Pro XLS b see page 4/22
Upgrade kits for Concept, PL7 Pro and ProWORX software
These upgrade kits allow users who already have these software programs from
the installed base and who have a current subscription to obtain Unity Pro version
V5.0 software at a reduced price. These upgrades are only available for licenses
of the same type (from Concept XL group license to Unity Pro Extra Large
group license). See pages 4/21 and 4/22.
Composition and Windows OS compatibility
Unity Pro multilingual software packages are compatible with Windows XP, Windows
Vista Business Edition (32-bit) and Windows 7 (32-bit) operating systems.
They include:
Unity Pro V5.0 DVD in six languages (English, French, German, Italian, Spanish b
and Chinese)
Unity Loader V2.1 CD b
Ethernet/IP Conguration V1.1 CD (not included with Unity Pro Small) b
DVD containing the documentation in six languages (English, French, German, b
Italian, Spanish and Chinese)
Unity Pro Small version 5.0 software
For Modicon M340: BMXP341000/20p0/20p02
For distributed I/O: Modicon ETB, FTB, FTM, OTB, STB, Momentum
Unity Pro Small version 5.0 software packages (1)
Designation License type Reference Weight
kg
Unity Pro Small
software packages
Single (1 station) UNYSPUSFUCD50
Group (3 stations) UNYSPUSFGCD50
Team (10 stations) UNYSPUSFTCD50
Software upgrades from:
- Concept S
- PL7 Micro
- ProWORX NxT/32 Lite
Single (1 station) UNYSPUSZUCD50
Group (3 stations) UNYSPUSZGCD50
Team (10 stations) UNYSPUSZTCD50
License type extensions for Unity Pro Small version 5.0
From To Reference Weight
kg
Single (1 station) Group (3 stations) UNYSPUSZUGCD50
Group (3 stations) Team (10 stations) UNYSPUSZGTCD50
(1) For compatibility of Unity software/automation platforms and distributed I/O, refer to the
selection guide on page 4/2.
References Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
Unity Pro
1
2
3
4
5
6
7
8
9
10
4/21
Selection guide:
page 4/2
Unity Pro Medium version 5.0 software
For Modicon M340: BMXP341000/20p0/20p02
For Modicon Premium: TSX570p to 2p, TSXPCI572p
For distributed I/O: Modicon ETB, FTB, FTM, OTB, STB, Momentum
Unity Pro Medium version 5.0 software packages (1)
Designation License type Reference Weight
kg
Unity Pro Medium
software packages
Single (1 station) UNYSPUMFUCD50
Group (3 stations) UNYSPUMFGCD50
Team (10 stations) UNYSPUMFTCD50
Software upgrades from:
- Concept S, M
- PL7 Micro, Junior
- ProWORX NxT/32 Lite
Single (1 station) UNYSPUMZUCD50
Group (3 stations) UNYSPUMZGCD50
Team (10 stations) UNYSPUMZTCD50
License type extensions for Unity Pro Medium version 5.0
From To Reference Weight
kg
Single (1 station) Group (3 stations) UNYSPUMZUGCD50
Group (3 stations) Team (10 stations) UNYSPUMZGTCD50
Upgrade to Unity Pro Medium from Unity Pro Small
Type of upgrade
The number of stations is unchanged
Reference Weight
kg
Small to Medium Single (1 station) UNYSPUMZSUCD50
Small to Medium Group (3 stations) UNYSPUMZSGCD50
Small to Medium Team (10 stations) UNYSPUMZSTCD50
Unity Pro Large version 5.0 software
For Modicon M340: BMXP341000/20p0/20p02
For Modicon Premium: TSX570p to 4p, TSXPCI572p to 3p
For Modicon Quantum: 140CPU311 10/434 12U/534 14U
For distributed I/O: Modicon ETB, FTB, FTM, OTB, STB, Momentum
Unity Pro Large version 5.0 software packages (1)
Designation License type Reference Weight
kg
Unity Pro Large
software packages
Single (1 station) UNYSPULFUCD50
Group (3 stations) UNYSPULFGCD50
Team (10 stations) UNYSPULFTCD50
Site (y 100 users) UNYSPULFFCD50
Software upgrades from:
- Concept S, M
- PL7 Micro, Junior, Pro
- ProWORX NxT/32 Lite
Single (1 station) UNYSPULZUCD50
Group (3 stations) UNYSPULZGCD50
Team (10 stations) UNYSPULZTCD50
Site (y 100 users) UNYSPULZFCD50
License type extensions for Unity Pro Large version 5.0
From To Reference Weight
kg
Single (1 station) Group (3 stations) UNYSPULZUGCD50
Group (3 stations) Team (10 stations) UNYSPULZGTCD50
Upgrade to Unity Pro Large from Unity Pro Medium
Type of upgrade
The number of stations is unchanged
Reference Weight
kg
Medium to Large Single (1 station) UNYSPULZMUCD50
Medium to Large Group (3 stations) UNYSPULZMGCD50
Medium to Large Team (10 stations) UNYSPULZMTCD50
(1) For compatibility of Unity software/automation platforms and distributed I/O, refer to the
selection guide on page 4/2.
References (continued) Modicon M340
automation platform
Unity Pro software
Medium / Large
Unity Pro
1
2
3
4
5
6
7
8
9
10
4/22
Selection guide:
page 4/2
Unity Pro Extra Large version 5.0 software
For Modicon M340: BMXP341000/20p0/20p02
For Modicon Premium: TSX570p to 6p, TSXPCI572p to 3p
For Modicon Quantum: 140CPU311 10/434 12U/534 14U/651 50/651 60/652 60/671 60
For distributed I/O: Modicon ETB, FTB, FTM, OTB, STB, Momentum
Unity Pro Extra Large version 5.0 software packages (1)
Designation License type Reference Weight
kg
Unity Pro Extra Large
software packages
Single (1 station) UNYSPUEFUCD50
Group (3 stations) UNYSPUEFGCD50
Team (10 stations) UNYSPUEFTCD50
Site (y 100 users) UNYSPUEFFCD50
Software upgrades from:
- Concept S, M, XL
- PL7 Micro, Junior, Pro
- ProWORX NxT Lite, Full
- ProWORX 32 Lite, Full
Single (1 station) UNYSPUEZUCD50
Group (3 stations) UNYSPUEZGCD50
Team (10 stations) UNYSPUEZTCD50
Site (y 100 users) UNYSPUEZFCD50
License type extensions for Unity Pro Extra Large
From To Reference Weight
kg
Single (1 station) Group (3 stations) UNYSPUEZUGCD50
Group (3 stations) Team (10 stations) UNYSPUEZGTCD50
Upgrade to Unity Pro Extra Large from Unity Pro Large
Type of upgrade
The number of stations is unchanged
Reference Weight
kg
Large to Extra Large Single (1 station) UNYSPUEZLUCD50
Large to Extra Large Group (3 stations) UNYSPUEZLGCD50
Large to Extra Large Team (10 stations) UNYSPUEZLTCD50
Unity Pro XLS version 4.1 software
For Modicon M340: BMXP341000/20p0/20p02
For Modicon Premium: TSX570p to 6p, TSXPCI572p to 3p
For Modicon Quantum: 140CPU311 10/434 12U/534 14U/651 50/651 60/652 60/671 60/
651 60S/671 60S
For distributed I/O: Modicon ETB, FTB, FTM, OTB, STB, Momentum
Unity Pro XLS version 4.1 software packages (1)
Designation License type Reference Weight
kg
Unity Pro XLS
software packages
Single (1 station) UNYSPUXFUCD41
Group (3 stations) UNYSPUXFGCD41
Team (10 stations) UNYSPUXFTCD41
Site (y 100 users) UNYSPUXFFCD41
Software upgrades from:
- Concept S, M, XL
- PL7 Micro, Junior, Pro
- ProWORX NxT Lite, Full
- ProWORX 32 Lite, Full
Single (1 station) UNYSPUXZUCD41
Group (3 stations) UNYSPUXZGCD41
Team (10 stations) UNYSPUXZTCD41
Site (y 100 users) UNYSPUXZFCD41
(1) For compatibility of Unity software/automation platforms and distributed I/O, refer to the
selection guide on page 4/2.
References (continued) Modicon M340
automation platform
Unity Pro software
Extra Large / XLS
Unity Pro
1
2
3
4
5
6
7
8
9
10
4/23
Selection guide:
page 4/2
Unity Pro software
Description License type Reference Weight
kg
Unity Developers Edition
UDE Unity Developers Edition
For automating repetitive tasks or generating source code
automatically from third-party applications
Available for Unity Pro Small, Medium, Large, Extra Large
and XLS
Single (1 station) UNYUDEVFUCD21E
Unity SFC View software
Unity SFC View software
packages
Single (1 station) UNYSDUMFUCD20
Unity Pro documentation, separate parts
Documentation for Unity Pro version 5.0
Description License type Reference Weight
kg
Hardware and software manuals (on DVD)
Platform setup for:
Modicon- M340
Premium-
Quantum-
Momentum-
Electromagnetic compatibility of networks and
eldbuses
Software setup for:
Unity- Pro
Function block libraries-
Multilingual (English, French,
German, Italian, Spanish,
Chinese)
UNYUSE909CDM
Separate parts
Description From processor To PC port Length Reference Weight
kg
PC connection cables
(PC to PAC)
USB mini B port
BMXP341000/20p0/20p02
USB port 1.8 m BMXXCAUSBH018 0.065
4.5 m BMXXCAUSBH045 0.110
Mini-DIN port Premium
TSX571p/2p/3p/4p Atrium
TSXPCI57
RS 232D (9-pin
SUB-D
connector)
2.5 m TSXPCX1031 0.170
USB port
(USB/RS 485
converter)
0.4 m TSXCUSB485
(2)
0.144
USB port
(mini-DIN/RJ45
cordset)
2.5 m TSXCRJMD25
(2)
0.150
Modbus port
15-way SUB-D Quantum
140CPU311 10 140CPU434
12A 140CPU534 14A
RS 232D (9-pin
SUB-D
connector)
3.7 m 990NAA26320 0.300
15 m 990NAA26350 0.180
USB port
Premium TSX575p/6p
Quantum 140CPU6p1
USB port 3.3 m UNYXCAUSB033
Modbus RJ45 connector port
Quantum 140CPU6p1
RJ 45
connector
1 m 110XCA28201
3 m 110XCA28202
6 m 110XCA28203
PC connection cables
(PC SUB-D to
Modicon STB I/O)
HE13 connector Modicon STB
I/O network interface module
(NIM)
RS 232D (3)
(9-way SUB-D
connector)
2 m STBXCA4002 0.210
USB/SUB-D adaptor
(PC USB to Modicon STB I/O)
HE13 connector Modicon STB
I/O network interface module
(NIM) with STB XCA 4002
cable (4)
USB port (4) SR2CBL06 0.185
(1) For compatibility of Unity software/automation platforms and distributed I/O, refer to the selection guide on page 4/2.
(2) The TSXCUSB485 converter requires use of the TSXCRJMD25 mini-DIN/RJ45 cordset.
(3) For connection on a USB port, the SR2 CBL 06 cable is required (4).
(4) Adaptor equipped with a USB connector (PC end) and a 9-way SUB-D connector (STB XCA 4002 cable end); requires the
STB XCA 4002 cable (9-way SUB-D/HE 13) for connection to the HE13 connector on the Modicon STB NIM.
References (continued) Modicon M340
automation platform
Unity Pro software
Small / Medium / Large / Extra Large / XLS
TSXCUSB485
TSXPCX1031
BMXXCAUSBH0pp
Unity Pro
1
2
3
4
5
6
7
8
9
10
4/24
Introduction
W@de W315, W320 and W325 modules allow the conguration of RTU tags via a
web interface. This process is time-consuming when dealing with a large number of
tags. RTU Conguration Software provides an easy to use graphical user interface
for:
Creating several tags according to IEC 60870-5-101/104 (DNP3 supported by
b
W@de modules) in just a few mouse clicks
Creating W@de conguration les for direct import into the module
b
Creating Unity
b Pro sections and variables, even Unity Pro applications, for
communication between the PAC and W@de RTU module
Creating user documentation based on MS Excel.
b
Software Setup
RTU Conguration Software can be used as a stand-alone utility or together with
Unity Pro. In the later case it is integrated into the Unity Pro programming software
on installation.
RTU variables
The software is used to create a large number of RTU variable tags automatically. It
supports the following variable types:
Single point/single command
b
Double point/double command
b
Measured value/set point command
b
Integrated total.
b
Conguration of additional RTU-specic parameters is also possible.
The naming rules for the automatically generated variables are dened as follows:
Optional PAC premount
b
IEC variable data type specic premount followed by a four-digit incremental
b
number
Object address
b
PAC address.
b
Communication parameters have to be congured directly in the W@de module web
interface.
Modicon M340
automation platform
Unity Pro software
RTU Conguration Software for Unity Pro and
W@de modules
Introduction,
setup
Software
RTU Configuration
Unity Pro Wade
RTU Configuration Software
Program Variables Configuration
RTU Conguration screen
1
2
3
4
5
6
7
8
9
10
4/25
Modicon M340
automation platform
Unity Pro software
RTU Conguration Software for Unity Pro and
W@de modules
References
Reference
RTU Conguration Software for Unity Pro and W@de modules is compatible with
Unity Pro V4.0 or higher and available for Microsoft Windows XP Professional
and Windows Vista.
The software requires Microsoft .NET framework V3.5 or higher and Microsoft
Internet Explorer V5.5 or higher.
W@de W315, W320 and W325 modules with rmware version V2.04 or higher
are supported.
Designation License type Reference Weight
kg
RTU Conguration
Software
Single (1 station) UNYSRTZFUCD10
1
2
3
4
5
6
7
8
9
10
4/26
Modicon M340
automation platform
Unity Pro software
Unity EFB Toolkit software
Introduction
Unity EFB Toolkit is the software for developing EFs and EFBs in “C” programming
language. It is optional for Unity Pro and is used to extend Unity Pro’s set of standard
function blocks to offer additional functionality. This software is bundled with
Microsoft Visual Studio for debugging function blocks developed in the Unity Pro
PAC Simulator. Unity EFB Toolkit also includes a service for creating and managing
function block families and integrating them in Unity Pro.
Setup
Unity EFB Toolkit handles the entire process of developing Unity Pro function blocks:
A user-friendly graphical user interface with automatic le organization
b
Powerful tools for testing and debugging
b
Management of compatibilities and software versions of created functions
b
Generation of les for subsequent installation of functions on other Unity Pro
b
stations.
Managing function families
The software is used to create function block families. The developed function
blocks, also known as EFs/EFBs, are stored in families, making it possible to create
an organized library of function blocks written in “C”. After development, these
function block families are installed on Unity Pro stations to extend the standard
Unity Pro libraries. Integration into Unity Pro can be executed from Unity EFB Toolkit
or by using the Unity Pro Types Library Update tool that makes it easy to distribute
the families without additional software.
Developping functions blocks
The EFB Toolkit software allows the user to create a function block by:
Declaring the function block interface in the same way as for DFBs in Unity Pro
b
Dening the necessary data types (elementary, structures, arrays)
b
Supporting public and private variables
b
Generating the les and the “C” code frame of the block (the user only adds the
b
functionality to this frame)
Granting access to numerous internal PAC services such as real-time clock, PAC
b
variables and data, system words and math functions, including high precision
numerical processing in “double” format
Building the function block family (compile/link for Unity Pro PAC platforms)
b
Providing a debugging environment: created function blocks can be easily
b
debugged in Microsoft Visual Studio by loading a Unity Pro application with the
developed function into the Unity Pro PAC Simulator. Microsoft Visual Studio
debugging functions, such as breakpoints, stepping operations, code/data
visualization and data manipulation, are available without restriction.
Supporting Unity Pro version management is important for the function block
b
maintenance phase.
Note: To generate the code for a Modicon M340 platform, a specic GNU compiler is used. It
is supplied with the Unity EFB Toolkit.
Compatibility
Unity EFB Toolkit is compatible with Unity Pro Small, Medium, Large and Extra
Large.
EFs and EFBs can be developed for the Premium, Modicon M340 and Quantum
platforms.
Introduction,
setup
EFB Toolkit: Managing function families
EFB Toolkit: Editor
Unity EFB Toolkit
1
2
3
4
5
6
7
8
9
10
4/27
Modicon M340
automation platform
Unity Pro software
Unity EFB Toolkit software
Reference
Unity EFB Toolkit is companion software for Unity Pro and is used to create Unity
Pro function blocks in “C” programming language. Developed function blocks can
then be integrated into Unity Pro standard function block libraries.
Unity EFB Toolkit software and its documentation are supplied in electronic form on
CD-ROM in English.
Designation License
type
Language Reference Weight
kg
Unity EFB Toolkit Single
(1 station)
English (software
and electronic
documentation)
UNYSPUZFUCD31E
References
1
2
3
4
5
6
7
8
9
10
4/28
Introduction
Unity Dif software is an optional program for Unity Pro supporting Unity Pro PAC
platforms. It compares two Unity Pro applications and provides an exhaustive list of
differences. The Unity Dif program increases productivity in the main life phases of a
control system, mainly during application development and debugging and
installation start-up, operation and maintenance.
Software setup
Unity Dif software can be launched in several ways:
From within Unity Pro
b
Via the Windows start menu
b
Via a command line interface without graphical user interface.
b
Unity Dif locates the differences between two Unity Pro applications in terms of:
The hardware conguration
b
The network conguration (Modbus
b /TCP, CANopen and RIO remote I/O
[Quantum only])
The entire set of variables and function block instances
b
The application structure and its content regardless of the language
b
The code for the DFBs and DDTs
b
The project options
b
The result of the comparison can be displayed in the user interface, printed or saved
in .txt le format.
Comparison
The end of the comparison operation is signalled by the appearance of the
application browser with its two tabs:
1 Identication tab for accessing the
Specications of the two applications being
compared. The differences are shown in a
summary.
2 Browser tab for accessing the application tree
structure reIntroduction.
Displaying results
The application structure reIntroduction is accessible after comparison via the
browser tab. It shows the difference with the help of 4 symbols in which the
information associated with application 1 appears in blue and those associated with
application 2 appear in red:
This branch, found in this level of the tree structure, contains at
least one difference
This block contains at least one difference
This section is only present in application 1
This section is only present in application 2
In the example opposite, a difference on the rung is detected:
1 The line displayed in blue belongs to application 1 [Prj1]
2 The line displayed in red belongs to application 2 [Prj2]
The source code extracts of both applications can be used to locate the differences
precisely.
Comparison after selection of elements to be analyzed
21
Displaying results
12
Modicon M340
automation platform
Unity Pro software
Unity Dif comparison application
Introduction,
setup
Unity Dif comparison
1
2
3
4
5
6
7
8
9
10
4/29
References
This Unity Dif software extension is used to compare two Unity applications
generated by Unity Pro software version V2.1 or later.
Description Target extension
PAC target
Type Reference Weight
kg
Unity Dif comparison
software extension for
Unity Pro applications
CD-ROM containing software
and electronic documentation
(English-French)
Unity Pro versions
Modicon M340,
Premium, Quantum
Single
license
(1 station)
UNYSDUZFUCD22
Site
license
(100
stations)
UNYSDUZFFCD22
Modicon M340
automation platform
Unity Pro software
Unity Dif comparison application
References
1
2
3
4
5
6
7
8
9
10
4/30
Modicon M340
automation platform
Unity Pro software
Unity Loader software
Introduction
Unity Loader is companion software to Unity Pro and is used to perform
maintenance operations on automation applications. Its easy setup and small size
make it a useful tool for updating Unity Pro projects without using Unity Pro. It is also
used to update the embedded software on Modicon M340 modules. It performs
the following main functions:
Transfer of automation project components from PC to PAC or from PAC to PC,
b
such as the program and data
Transfer of les and user Web pages stored in the memory card of
b
Modicon M340 PACs
Transfer of embedded software (rmware) from the PC to Modicon M340 modules.
b
Software graphic interface
The Unity Loader software is easy to use and consists of four tabs to perform
different operations:
The
b Projecttab is used for project transfers (program and data) between the PC
and the PAC processor. The software transfers program (application le format .stu
and archive le format .sta) and data (located and unlocated) les of a Unity Pro
project in either direction. Program and data les created by Unity Loader are
compatible with Unity Pro. When connected to the PAC, Unity Loader displays the
information relating to the data read in the PAC. The same information is displayed
for the selected les on the PC. The user decides which of the possible elements of
the project are transferred in a single command after validation of the transfers.
Modicon M340 PACs and BMXRMS vpp8MFP memory card only: User les and
Web pages can be transferred from the memory card to the PC and vice versa.
BMXNOE0110 with Flash Memory Card only v: Web pages stored inside the
Flash Memory can be transferred from the module to the PC or vice versa.
The
b Firmwaretab is used to update the rmware in Modicon M340 modules.
The screen displays the detailed content of the rmware versions inside the module
and on the PC. The rmware update follows the same principle as for transferring
projects.
The
b Optionstab is used to congure the working environment, such as the le
location on the PC and selection of one of the six supported languages (English,
French, German, Italian, Spanish, and Chinese) for the user interface and online
help.
The
b About to tab displays information about the software.
Note: Regardless of which tab is selected, the connection status with the PAC is displayed,
together with commands for connection/disconnection and changing the PAC operating mode.
Modicon M340 PACs and BMXRMSpp8MFP memory card only
Unity Loader software can download the project components and rmware (PAC or
module) simultaneously onto the ash memory card (BMXRMSpp8MFP memory
card only) slotted in the processor.
This rmware download can subsequently be used to update a remote PAC.
Automation of Unity Loader commands
Project download/upload between a PAC and a supervisory station equipped with
Unity Loader software is now possible through a command le included in the
supervisory application.
Introduction
Unity Loader
Unity Loader: "Project" tab
Unity Loader: "Firmware" tab
1
2
3
4
5
6
7
8
9
10
4/31
Modicon M340
automation platform
Unity Pro software
Unity Loader software and Libraries
Communication between the PC and the PAC
Unity Loader supports:
Unity Pro Quantum
b PACs with Modbus communication
Unity Pro Premium
b PACs with Unitelway communication
Modicon
b M340 PACs and modules via Ethernet and USB.
Reference Type of module Ethernet port USB port
BMXP342000 Processor with Modbus
BMXP342010/20103 Processor with CANopen
BMXP342020 Processor with integrated
Ethernet port
BMXP342030/20302
BMXNOE0100/0110 Ethernet Modbus/TCP
BMXAMI/ART/AMO/AMM Analog I/O
BMXEHC0200/0800 Counter
BMXMSP0200 Motion control
Supported Supported if processor with integrated Ethernet port
For Ethernet networks Unity Loader contains a network scanner to scan a range of
network addresses. By selecting a recognized Modicon M340 PAC the data transfer
operations can be performed.
Reference
Unity Loader is included with Unity Pro Small, Medium, Large and Extra Large and
can be ordered separately under a unit reference.
Compatibility
Unity Loader is independent of Unity Pro and compatible with Modicon M340 PACs,
Unity Pro Quantum PACs via Modbus and Unity Pro Premium PACs via Unitelway.
Program les and PAC data les are compatible between Unity Pro and Unity Loader.
Designation Type Reference Weight
kg
Unity Loader Single license
(1 station)
UNYSMUZUCD22
Specic libraries according to the software used
The specic libraries below may be acquired separately according to the software
used.
Control Libraries
Designation Target
software
Type Reference Weight
kg
Predictive Control Library Unity Pro /
Concept
Single
license
(1 station)
UNYLPCZAUCD10
Fuzzy Library Unity Pro UNYLFZZAUWB12
TeSys Library UNYLTSZAUWB10
Heat Ventilation Air Condition
Library
UNYLHVZAUWB10
Flow Calculation Library UNYLAGZAUWB20
System Libraries
Designation Target
software
Type Reference Weight
kg
Enhanced Process Library UAG Single
license
(1 station)
UAGSBTCFUCD10
Devices and Process Library UAGSBTDFUWB13
Introduction (continued),
references
Unity Loader
Unity specific Libraries
1
2
3
4
5
6
7
8
9
10
4/32
Introduction Modicon M340
automation platform
Unity software
Unity Application Generator
Advanced design tool for automation solutions (1)
Deliver your automation projects faster and re-use your know-how!
Unity Application Generator (UAG) is an advanced design and generation software
tool that integrates multiple PACs and HMI/SCADA systems to provide an
automation solution similar to a distributed control system. Using an approach based
upon reusable objects (application libraries) and automatic application generation,
UAG helps to ensure consistent design and implementation of user-dened
standards and specications. Featuring change tracking and automatic
documentation functions, UAG supports standards such as ISA-88 and GAMP.
Business advantage
UAG provides signicant business advantages in terms of cost reduction, quality and
performance improvement.
Cost b
Savings in system implementation cost v
Improved time-to-market for the end user by allowing the project v
Quicker return on investment v
Quality b
Improved software quality, v
Improved maintainability v
Reduced risk and improved project schedules v
Performance b
Standardized design and systematic improvement v
Capture and re-use of your best practices v
Integrated automation system design in your plant engineering workow v
Working efciently
UAG provides the key features for an advanced automation solution to increase
efciency, and to share and re-use your know-how.
Structured project design - bridge from the process engineer to the control/
automation designer (from the PID to the automation system).
It is possible to capture and re-use the customer’s best practices within application
specic libraries that reduce the dependency on experts, allows standardization
and increases software robustness.
Single database entry helps to avoid duplicate effort and resulting errors.
Automatic application generation, including the automatic conguration of
networks in multi device systems increases efciency, improves software quality
and shortens setup times while simultaneously reducing project risk. Integrated
change tracking and automatic documentation generation reduces engineering
effort and enables system validation.
Advanced automation platform
UAG integrates products from Schneider Electric and leading partners into an
advanced automation platform based on standards, including: ISA-88, GAMP and
IEC 61131-3.
Single data point entry and management integrates the process control, monitoring
and supervision and helps to ensure data consistency and integrated communication
among devices.
Applications (1)
Methodology b: UAG allows you to capture and re-use your know-how. Through
automatic generation, the project information is propagated to applications
consistently, easily and quickly.
Creating user libraries b: libraries are based on re-usable control devices Smart
Control Devices (SCoDs).
High level objects (template types) consisting of multiple SCoDs b: template
types allow you to pre-dene complex objects (e.g. a PID or a sequence) that consist
of multiple SCoDs. A common graphic symbol can also be dened. This makes
instantiation more efcient as the number of individual steps can be reduced by
using the type denition.
Structuring your project b: a structured project design provides a bridge from the
process engineer to the control automation designer (from the PID to the automation
system) based on the ISA-88 standard. The PID drawing is mapped to the physical
model in UAG.
(1) For more technical information, please consult our website at www.schneider-electric.com.
Standards
Working efciently
Unity Pro
a SoCollaborative Software
Vijeo Citect
a SoCollaborative Software
XML
UAG
Process design
(PID, Excel,
XML, CAD, …)
Business advantage
SoCollaborative
Engineering project
Conventional Project
Basic design
Basic design
System
design Detailed
design Procurement &
Commissioning
Reduced schedule
Detailed design Procurement & Commissioning
UAG
1
2
3
4
5
6
7
8
9
10
4/33
Introduction (continued),
references
Modicon M340
automation platform
Unity software
Unity Application Generator
Applications (continued) (1)
Multi-station automation conguration b: the entire process control, monitoring and
supervision topology of the distributed automation system is managed within UAG.
Generating the application b: the automation solution is generated based on the
structured design and your standards contained within the pre-qualied UAG library,
helping to ensure consistent information for the PACs and the HMI/SCADA. The use
of resources (addresses, name space, etc.) is optimized to help avoid conicts and
errors. UAG can generate complete projects, as well as incremental changes when
modications occur.
Validation b: UAG simplies validation when required by regulation or to comply
with GAMP (Good Automation Manufacturing Practice). UAG uses ISA 88 standard
terminology for batch control and supports the GAMP methodology for creating an
automation system.
Process Application Library for Vijeo b Citect: the Process Application Library
for Vijeo Citect is shipped together with the UAG CD and can be installed from there.
A separate order is not necessary; simply complete the registration details
during installation.
Device and Process Library b: the Device and Process Library is shipped together
with the UAG CD and can be installed from there. A separate order is not necessary;
simply complete the registration details during installation.
Segment/Application-specic libraries
A number of more specialized libraries have been developed to provide a more
complete starting point for certain projects, such as:
Water & Wastewater b
Mining, Minerals, Metals b
Supported platforms and environment
Supported platforms b
PAC software: Unity v Pro u V4.0
PAC hardware: M340 v, Premium and Quantum
M340 I/O, Premium I/O, Quantum I/O and Modicon v I/O
Modbus v TCP and Modbus Plus
Fieldbus support v
HMI/SCADA b
Vijeo Citect v u V6.1
Wonderware Archestra V3.0 v
OPC v data server software (OFS)
Other HMI/SCADA via the UAG “Plug-In” interface v
Export of information for other devices/applications b
XML export le v
CSV export le v
Environment b: Compatible with Microsoft Windows® 7 Professional (2), Windows
Vista® Business and Windows® XP Professional operating systems
References (1)
Description License type Reference Weight
kg
UAG software suites (3)
Comprising:
UAG (Unity Application b
Generator) software in
English, French, German,
Documentation (electronic b
format)
Single (1 station) UAGSEWLFUCD33
Site (> 10 stations) UAGSEWLFFCD33
SoCollaborative
Engineering
Includes Unity Pro, Vijeo
Citect, Web Designer,
UAG/sg² software
Single (1 station) EUSENG2CFUV11
Team (10 stations) EUSENG2CFTV11
(1) For more technical information, please consult our website at www.schneider-electric.com.
(2) Please contact our Customer Care Center.
(3) The PAC/SCADA programming tools and/or communication drivers are ordered separately.
Multi-station automation conguration
Graphic object Logic object
ScoD
Instantiation
Generation
HMI PAC Documentation
Generating the application
UAG
1
2
3
4
5
6
7
8
9
10
4/34
Vijeo Historian:
page 4/48
Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
Introduction
Vijeo
Citect
software
Twido
PLC
Modicon
M
3
40
P
A
C
Modic
o
n
P
rem
i
um
M
o
dico
n
Quantu
m
M
a
g
e
l
i
s
Sm
art
Ma
g
e
l
i
s
Com
pa
c
t &
iPC
Modu
l
ar
i
PC HMI
M
a
geli
s
XB
T
GT HMI
Vijeo
Designer
software
PC
Vijeo
Historian
software
&
C
o
m
pact iPC HMI
PAC PAC
Vijeo Citect software is the operating and monitoring component of
PlantStruxure , the new process automation architecture of Schneider Electric.
With its powerful display capabilities and its operational features, it delivers
actionable insight faster, enabling operators to respond quickly to process
disturbances, thereby increasing their efciency. With its easy-to-use conguration
tools and powerful features you can quickly develop and implement solutions for any
size application.
Vijeo Citect software offers the functions of a modern supervisor. Its distributed
client-server architecture is applicable to a multitude of applications in the following
markets:
Oil & Gas
b
Mining, Minerals, Metals
b
Water & Wastewater
b
Power
b
Food and beverage
b
Its exibility also makes it suitable for numerous other application areas, such as
infrastructures.
Redundancy
Vijeo Citect software offers redundancy for the components of the system. The
redundancy functions are fully integrated in the system, providing exceptional
performance and intuitive conguration.
Server license
Vijeo Citect software is available:
In a
b Client-Server architecture, for congurations ranging from 75 points to an
unlimited number of points
In a
b stand-alone version called Vijeo Citect Lite, for congurations of 100 to
1200 points (see page 4/38).
Vijeo Citect software includes the installation (without registration) of the OFS
software, Schneider Electric's integrated OPC server. This server can only be used
with Vijeo Citect software.
The OFS software provides access to the structured variables and helps to ensure
system consistency. This is one of the major benets of Schneider Electric integration.
Server licenses VJCNS1011 pp are purchased according to the number of points to
be processed, not according to the number of I/O (1).
An upgrade offer VJCNS1011 pp-pp is also available to increase the number of
client and server points, as required (2).
(1) Vijeo Citect software counts the variables exchanged with external devices, such as PACs.
(2) If the server or client is upgraded, the keys must be reprogrammed.
Introduction
Vijeo Citect
1
2
3
4
5
6
7
8
9
10
4/35
Vijeo Historian:
page 4/48
Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
Introduction (continued)
Client licenses
Four types of client license are available:
Control Client b, VJCNS1020pp: used by operators accessing the Vijeo Citect
server via a local connection
View Only Client b, VJCNS1030pp: for users needing to view the Vijeo Citect
application via a local connection, but not needing to control the system
Web Control Client b, VJCNS1022pp: similar to the Control Client, but via a Web
browser
Web View Only Client b, VJCNS1032pp: similar to the View Only Client, but via a
Web browser
Static, oating and redundant client licenses
A client license can be static, oating or redundant depending on requirements:
Static client license
b : For operators needing access to the system, regardless of
the number of connections already established by other clients.
A static client license provides permanent access to the system, as it physically
resides in the key plugged into the client PC.
Floating client license
b : Users who occasionally need to use a client for operator
tasks can purchase oating licenses. Connections will be allowed until the number of
valid licenses is reached. Floating client licenses are stored on the key plugged into
the server.
Redundant client license
b : Redundant client licenses VJCNS10pp88 are used
solely for the standby server in a redundant conguration. They are used to help
ensure that the client licenses purchased are available.
Development workshop
The development workshop VJC1099pp is comprised of hardware components
such as the DVD, hardware keys, installation guide and storage boxes.
The rules for use are as follows:
Each server requires a hardware key (USB or parallel) to operate
b
The server key is also used to store the oating client licenses
b
The key controls the number of points that can be used
b
The key is programmed to operate up to a predetermined version
b
1
2
3
4
5
6
7
8
9
10
4/36
Vijeo Historian:
page 4/48
Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
Architectures
Single station stand-alone SCADA system, 5000 points
Development workshop
1 x bVJC109922, hardware delivery of the DVD with USB key
Server license
1 x bVJCNS101114, server license for 5000 points, including client server
Client license
Not required (included in the server license) b
Remote server system with remote access via the Web
Development workshop
1 x bVJC109922, hardware delivery of the DVD with USB key
Server license
1 x bVJCNS101115, server license for 15000 points, including client server
Client license
1 x bVJCNS103299, Web View Only Client license
Networked server system with remote Web clients
E.g. Networked server system, 500 points, with 2 remote clients via the Web,
one Web Control Client and one Web View Only Client
Development workshop
1 x bVJC109922, hardware delivery of the DVD with USB key
Server license
1 x bVJCNS101112, server license for 500 points, including client server
Client licenses
1 x bVJCNS102212, Web Control Client license for 500 points
1 x bVJCNS1032 99, Web View Only Client license
Architectures
Single-station architecture
Single-station architecture
Single-server architecture with Web View Only Client access
Single-server architecture with Web View Only Client access
Single-server architecture with
1 Web Control Client and 1 Web View Only Client
Single-server architecture with
1 Web Control Client and 1 Web View Only Client
1
2
3
4
5
6
7
8
9
10
4/37
Vijeo Historian:
page 4/48
Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
Architectures (continued)
Networked server system with oating and static access
E.g. Networked server system, 5000 points, with 5 client PCs and 3 client licenses
(2 oating and 1 static)
Development workshop
1 x bVJC109922, hardware delivery of the DVD with USB key
1 x bVJC109921, additional USB key for static client
Server license
1 x bVJCNS101114, server license for 5000 points, including client server (local
Control Client type on the server PC)
Client licenses
3 x bVJCNS102014, Control Client licenses for 5000 points
Redundant server with Server Control Clients and Web View Only Clients
E.g. Redundant server, 1500 Points, with 2 Control Client licenses on the servers and
2 Web View Only Client licenses
Development workshop
1 x bVJC109922, hardware delivery of the DVD with USB key (primary server key)
1 x bVJC109921, additional USB key for standby server
(rule: 1 key per server)
Server licenses
2 x bVJCNS101113, server licenses for 1500 points, including client server
The rst server acts as the primary server v
The second server acts as the standby server v
One license is placed on each key (primary and standby) v
Client licenses
2 x bVJCNS103299, Web View Only Client licenses
Both licenses are placed on the primary server key v
Redundant client license
2 x bVJCNS103288, redundant Web View Only Client license
Floating redundant licenses for Web View Only Client licenses v
Both licenses are placed on the standby server key v
Architectures (continued)
Single-server architecture with
2 oating Control Client licenses and 1 static license
Single-server architecture with
2 floating Control Client licenses and 1 static license
Floating licenses Static license
Redundant architecture with
2 Control Clients on servers and 2 Web View Only Clients
Redundant architecture with
2 Control Clients on servers and 2 Web View Only Clients
1
2
3
4
5
6
7
8
9
10
4/38
Vijeo Historian:
page 4/48
Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
References
VJC1099p2
Vijeo Citect
Development workshop - Vijeo Citect Box and keys
The VJC1099p2 Vijeo Citect Box is comprised of:
DVD with the Vijeo Citect software
b
Schneider Electric drivers pack
b
Installation guide
b
Hardware key (for USB or parallel port)
b
Additional keys are also supplied in the Vijeo Citect Box.
Development workshop - Vijeo Citect Box
Description Type of key
included
Reference Weight
kg
Vijeo Citect Box
with USB key
USB VJC109922 0.410
Vijeo Citect Box
with parallel key
Parallel VJC109912 0.420
Additional Vijeo Citect keys
Designation Target license Reference Weight
kg
Additional Vijeo Citect USB key
Supplied in Vijeo Citect Box
Redundant server and
static (non-oating) licenses
VJC109921
Additional Vijeo Citect parallel
key
Supplied in Vijeo Citect Box
Redundant server and
static (non-oating) licenses
VJC109911
Vijeo Citect 10 Pack USB keys
Supplied in Vijeo Citect Box
Blank keys and not licensed VJC109920
(1)
Vijeo Citect 10 Pack Parallel
keys
Supplied in Vijeo Citect Box
Blank keys and not licensed VJC109910
(1)
Vijeo Citect Demonstration software
Designation Target license Reference Weight
kg
Vijeo Citect Software DVD -
50 Pack
Supplied in Vijeo Citect Box
Demonstration software
DVD pack
VJC109918
Vijeo Citect Lite software, stand-alone
The Vijeo Citect Lite software stand-alone license for 100 to 1200 points includesf:
DVD with the Vijeo Citect software
b
Schneider Electric drivers pack
b
Installation guide
b
Hardware key
b
The Vijeo Citect Lite software license is a simple solution for stand-alone
applications. This license is used to connect a single client to a single sector. It
cannot be made redundant.
Vijeo Citect Lite software license
Designation Number of points Reference Weight
kg
Vijeo Citect Lite software
Stand-alone: no connectivity
Key to be ordered separately
100 VJCNS301156
150 VJCNS301111
300 VJCNS301127
600 VJCNS301159
1200 VJCNS301150
(1) The 10 Packs Vijeo Citect keys VCJ 1099 20 and VCJ 1099 10 are not programmed.
1
2
3
4
5
6
7
8
9
10
4/39
Vijeo Historian:
page 4/48
Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
References (continued)
Vijeo Citect
Vijeo Citect Lite software upgrades
The references below are used for increasing the number of Vijeo Citect Lite software
points available or to upgrade Lite server to Full server.
Designation Number of points Reference Weight
kg
Vijeo Citect Lite software
upgrade
(number of points)
100 to 150 VJCNSL56-L11
150 to 300 VJCNSL11-L27
300 to 600 VJCNSL27-L59
600 (1) to 1200 VJCNSL59-L50
Vijeo Citect Lite software
upgrade
(Lite server to Full server)
Lite 150 to Full 150 VJCNSL11-F11
Lite 300 to Full 500 VJCNSL27-F12
Lite 600 to Full 1500 VJCNSL59-F13
Lite 1200 to Full 1500 VJCNSL50-F13
Vijeo Citect Server software
The Vijeo Citect Server software full system licenses are segmented according to
the number of points. They include:
DVD with the Vijeo Citect software
b
Schneider Electric drivers pack
b
Installation guide
b
Hardware key
b
Redundant system
For a redundant system simply order 2 Vijeo Citect Server software licenses
b
No other option is required for the servers
b
The programmed key (USB or parallel) is ordered separately
b
Vijeo Citect Server software license
Designation Number of points Reference Weight
kg
Vijeo Citect Server software
Full version
Key to be ordered separately
75 VJCNS101110
150 VJCNS101111
500 VJCNS101112
1500 VJCNS101113
5000 VJCNS101114
15000 VJCNS101115
Unlimited VJCNS101199
Vijeo Citect Server software upgrades
The references below are used for increasing the number of points on the server.
Designation Number of points Reference Weight
kg
Vijeo Citect Server softwrae
upgrade
Full server point expansion
75 to 150 VJCNS101110-11
150 to 500 VJCNS101111-12
500 to 1500 VJCNS101112-13
1500 to 5000 VJCNS101113-14
5000 to 15000 VJCNS101114-15
15000 to unlimited VJCNS101115-99
(1) Also for existing installed Lite 500 point versions.
1
2
3
4
5
6
7
8
9
10
4/40
Vijeo Historian:
page 4/48
Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
References (continued)
Vijeo Citect Control Client software
Vijeo Citect Control Client software licenses are for operators. They are segmented
according to the number of points to be displayed. There are two types:
Floating license, residing on the server key
b
Static license, requiring a separate key on the client PC
b
Redundant system
The number of oating clients ordered is added to the primary server key
b
For the standby server, the same number of redundant Control Client software
b
licenses, VJCNS103088, are ordered separately
Vijeo Citect Control Client software license
Designation Number of points Reference Weight
kg
Vijeo Citect Control Client
software license
75 VJCNS102010
150 VJCNS102011
500 VJCNS102012
1500 VJCNS102013
5000 VJCNS102014
15000 VJCNS102015
Unlimited VJCNS102099
Vijeo Citect redundant
Control Client software license
Floating license
only
VJCNS102088
Vijeo Citect View Only Client software
Vijeo Citect View Only Client software licenses are available for users who need to
view the application, without controlling it. Licenses for these clients are segmented
according to the number of points displayed. There are two types:
Floating license, residing on the server key
b
Static license, the hardware key being plugged into the client station
b
Redundant system
The number of oating clients ordered is added to the primary server key
b
For the standby server, the same number of redundant View Only Client software
b
licenses, VJCNS1030 88, are ordered separately
Vijeo Citect View Only Client software license
Designation Number of points Reference Weight
kg
Vijeo Citect View
Only Client software license
Unlimited VJCNS103099
250 simultaneous
connections
VJCNS103788
Vijeo Citect redundant
View Only Client software
license
Floating license
only
VJCNS103088
250 simultaneous
connections
VJCNS103688
1
2
3
4
5
6
7
8
9
10
4/41
Vijeo Historian:
page 4/48
Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
References (continued)
Vijeo Citect Web Control Client software
Vijeo Citect Web Control Client software licenses are for users who need control of
the application but prefer the exibility of access via a Web connection. These client
licenses are segmented according to the number of points displayed and are the
oating type (residing on the key plugged into the server).
Redundant system
The number of oating clients ordered is added to the primary server key b
For the standby server, the same number of redundant View Only Client software b
licenses, VJCNS103088, are ordered separately
Vijeo Citect Web Control Client software license
Designation Number of points Reference Weight
kg
Vijeo Citect
Web Control Client software
license
75 VJCNS102210
150 VJCNS102211
500 VJCNS102212
1500 VJCNS102213
5000 VJCNS102214
15000 VJCNS102215
Unlimited VJCNS102299
Vijeo Citect redundant
Web Control Client software
license
Floating license
only
VJCNS102288
Vijeo Citect Web View Only Client software
Vijeo Citect Web View Only Client software licenses are for users who need to view
the application via a Web connection, without controlling the system. These client
licenses are segmented according to the number of points displayed and are the
oating type (the licenses reside on the key plugged into the server).
Redundant system
The number of oating clients ordered is added to the primary server key
b
For the standby server, the same number of redundant View Only Client software
b
licenses, VJCNS103288, are ordered separately
Vijeo Citect Web View Only Client software license
Designation Number of points Reference Weight
kg
Vijeo Citect Web View
Only Client software license
Unlimited VJCNS103299
250 simultaneous
connections
VJCNS103988
Vijeo Citect redundant
Web Only Client View software
license
Floating license
only
VJCNS103288
250 simultaneous
connections
VJCNS103888
Vijeo Citect
1
2
3
4
5
6
7
8
9
10
4/42
Vijeo Historian:
page 4/48
Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
References (continued)
Control Client software upgrades
The references below are used for increasing the number of points on:
The server holding the hardware key, for oating licenses
b
The client holding the hardware key, for static licenses
b
Vijeo Citect Control Client software upgrade
Designation Number of points Reference Weight
kg
Vijeo Citect
Control Client
software upgrade
75 to 150 VJCNS102010-11
150 to 500 VJCNS102011-12
500 to 1500 VJCNS102012-13
1500 to 5000 VJCNS102013-14
5000 to 15000 VJCNS102014-15
15000 to unlimited VJCNS102015-99
View Only Client software upgrade
The reference below is used for increasing the number of points on:
The server holding the hardware key, for oating licenses
b
The client holding the hardware key, for static licenses
b
Vijeo Citect View Only Client usoftware pgrade
Designation Number of points Reference Weight
kg
Vijeo Citect
View Only Client
software upgrade
Unlimited VJCNS103099-99
Web Control Client software upgrades
The references below are used for increasing the number of points on the server
holding the hardware key.
Vijeo Citect Web Control Client software upgrade
Description Number of points Reference Weight
kg
Vijeo Citect
Web Control Client
software upgrade
75 to 150 VJCNS102210-11
150 to 500 VJCNS102211-12
500 to 1500 VJCNS102212-13
1500 to 5000 VJCNS102213-14
5000 to 15000 VJCNS102214-15
15000 to unlimited VJCNS102215-99
Web View Only Client software upgrade
The reference below is used for increasing the number of points on the server holding
the hardware key.
Vijeo Citect Web View Only Client software upgrade
Designation Number of points Reference Weight
kg
Vijeo Citect
Web View Only Client
software upgrade
Unlimited VJCNS103299-99
Connections, miscellaneous
The references below are used to expand the connection licenses.
Designation Reference Weight
kg
OPC Server license VJC104188
CtAPI license VJC104288
Time scheduler (1) VJC903288
(1) New version of the Time Scheduler software, available via web download only. Previous
versions are not capable of being migrated to Vijeo Citect software version 7.20.
1
2
3
4
5
6
7
8
9
10
4/43
Vijeo Historian:
page 4/48
Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
References (continued)
Vijeo Citect software - Specic drivers
The Vijeo Citect software offer includes a large number of drivers as standard.
However, for copyright reasons, some drivers have a specic reference and are
ordered separately.
The purchase of a specic driver includes access to the appropriate technical
support for the driver for one year.
Designation Protocol Reference Weight
kg
Vijeo Citect software
specic driver
IEC 60870-5-104 VJCNS305141
PSDirect ETH VJCNS305140
PSDirect MPI VJCNS305142
Bailey VJCNS305144
SEMAPI VJCNS305148
MOSCAD VJCNS305149
KONNEX VJCNS305146
BACnet VJCNS305151
Note: Before ordering a Vijeo Citect software specic driver, please contact our Customer Care
Center.
Reprogramming for a Vijeo Citect software license transfer
Each time a license has to be transferred from an existing key to another key,
transfer fees are applicable and the reference VJC109401 is ordered separately
(license transfer token).
Examples of cases in which these fees are applicable:
Transfer of a client license from a static key to a oating license on a server b
Transfer of an existing oating license to a new static key b
These fees are also applicable when transferring license(s) to a replacement key.
If a new key is required, you need to order a new hardware key VJC1099pp.
Designation Reference Weight
kg
Reprogramming for Vijeo Citect
software license transfer
VJC109401
Driver Development Kit
The driver development kit includes:
The latest release of Vijeo Citect software, example source code, utilities and b
other Vijeo Citect software les required in developing a Citect driver.
A hardware key that will allow runtime up to 8 hours and is a 42,000 pt. single user b
license.
Access to “Citect Drivers Developers” area on Citect DriverWeb at b
scadasupport.citect.com/driverweb.
Designation Reference Weight
kg
Driver Development Kit VJC109206
Vijeo Citect
1
2
3
4
5
6
7
8
9
10
4/44
Vijeo Historian:
page 4/48
Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
Conversion of third-party applications
Conversion tools help to convert legacy applications (such as Monitor Pro) or other
third-party applications to Vijeo Citect software. These programs convert the tag
database and graphic information to make them compatible with Vijeo Citect software:
Page Import b tool is targeted at customers who wish to perform the entire
engineering portion of the legacy system migration themselves. The System
Integrators perform the engineering themselves.
Basic Sytem Conversion
b tool is targeted at customers that want the new system
to simply replace the legacy system without major changes. It includes an initial
generic engineering component to produce a fully compiled Vijeo Citect software
project that is ready for Factory Acceptance Tests.
Details of the coverage provided by these conversion tools can be found in our
internet site www.schneider-electric.com.
Designation Legacy System
supported
Reference Weight
kg
Basic System Conversion
(minimum 10 pages)
Tier 1 (1) VJC109081
Tier 2 (2) VJC109082
Tier 3 (3) VJC109083
Page Import
(minimum 10 pages)
Tiers 1, 2, and 3 VJC109088
Loan of Vijeo Citect software keys (4)
Designation Content Reference Weight
kg
Loan of single
Vijeo Citect software key
- 1 server license,
unlimited number of points,
VJCNS101199
- 1 scheduler, VJC903288
VJC109511
Loan of multiple
Vijeo Citect software keys
- 1 server license,
unlimited number of points,
VJCNS101199
- 5 oating Control Client licenses,
VJCNS102099
- 5 oating View Only Client
licenses, VJCNS103099
- 2 oating Web Control Client
licenses, VJCNS102299
- 2 oating Web View Only Client
licenses, VJCNS103299
- 1 scheduler, VJC903288
VJC109512
(1) Tier 1 = FactoryLink 5 to 6.x, MonitorPro 2, Mount32, Genesis32, Cimplicity, Moore APACS,
Wonderware 5.x to 9.x.
(2) Tier 2 = iMount 3.5, Delta V (Mount32 & iMount 3.5), RSView32 6.4, FactoryLink 7.5,
MonitorPro 7.2 & 7.6, VijeoLook 2.6, WinCC 6.0, Wizcon.
(3) Tier 3 = iMount 4.5, DeltaV (iMount 4.5), Telvent OASyS DNA / 6.x, Telvent OASyS 5.x,
Telvent Vector (RTView & Ovision), Honeywell TDC3000, Vigile.
(4) Available for customers requiring temporary access to a key. The hardware key is to be
returned at the end of the loan period. Provides eight days of continuous use. Also requires
an additional Vijeo Citect Box USB key, VJC1099pp, to obtain the hardware key. The quantity
corresponds to the number of months of the loan.
References (continued)
1
2
3
4
5
6
7
8
9
10
4/45
Vijeo Historian:
page 4/48
Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
References (continued)
Alliance Software Packs
Alliance Software Pack V1.0
The Alliance Software Pack V1.0 offer is exclusively for systems integrators who are
active partners in the new Schneider Electric Alliance program (i.e. those who pay the
annual Alliance partnership subscription).
The package is comprised of:
SoCollaborative
b Alliance (DVD Box):
sg2 V3.5 (multi) v
Unity v Pro XL V4.1 (10 stations)
Unity v Loader V2.1
Vijeo v Citect Build-Time V7.10r2 (multi)
Vijeo v Citect Run-Time (2x12-hour hardware keys)
Web Designer V2.15 (multi) v
Advantys v Congurator V4.5 (multi)
Ethernet/IP I/O Congurator V1.1 (multi) v
DVD: electronic documentation V4.1 v
CD: Drivers V2.6 v
Legacy software suite
b (online download):
Concept v XL V2.6 SR5 (10 stations)
PL7 v Pro V4.5 SP5 (10 stations)
ProWorx v 32 V2.1 SP1 patch A (10 stations)
XBTL1003 V4.51 (multi) v
Other software tools
b (online download):
Vijeo v Historian Server/Client build V4.1
Vijeo v Designer V5.0 for HMI (1 station)
Sycon v V2.9 for network (10 stations)
Advantys v PAC Image Generator V2.0
Advantys v CANopen Symbol Exp. V2.0
TwidoSuite v V2.20, TwidoSoft V3.5
ZelioSoft v 2 V4.3, ZelioCom V2.08, ZelioAlarm 2 V1.5
PowerSuite for drives V2.6 patch1 v
Libraries for Unity v Pro:
- TeSys, Fuzzy Control, HVAC, Predictive Control, Flow Calculation libraries
Application libraries for UAG and sg2: v
- Device & Process libraries
Vijeo Citect
1
2
3
4
5
6
7
8
9
10
4/46
Vijeo Historian:
page 4/48
References (continued) Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
Alliance Software Pack Pro V1.0
The Alliance Software Pack Pro V1.0 offer is exclusively for systems integrators who
are active partners in the Schneider Electric PlantStructure Certied Alliance
Partners program.
The package is comprised of:
SoCollaborative
b Alliance Pro (DVD Box):
UAG V3.2 (10 stations) v
sg2 V3.5 (10 stations) v
Unity v Pro XL V4.1 (10 stations)
Unity v Loader V2.1
Vijeo v Citect Build-Time V7.10r2 (multi)
Vijeo v Citect Run-Time (4x12-hour hardware keys)
Web Designer V2.15 (multi) v
Advantys v Congurator V4.5 (multi)
Ethernet/IP I/O Congurator V1.1 (multi) v
DVD: electronic documentation V4.1 v
CD: Drivers V2.6 v
Legacy software suite
b (online download):
Concept v XL V2.6 SR5 (10 stations)
PL7 v Pro V4.5 SP5 (10 stations)
ProWorx v 32 V2.1 SP1 patch A (10 stations)
XBTL1003 V4.51 (multi) v
Other software tools
b (online download):
Vijeo v Historian Server/Client build V4.1
Vijeo v Designer V5.0 for HMI (1 station)
ConnexView v Server/Client V2.0
Sycon v V2.9 for network (10 stations)
Advantys v PAC Image Generator V2.0
Advantys v CANopen Symbol Exp. V2.0
TwidoSuite v V2.20, TwidoSoft V3.5
ZelioSoft v 2 V4.3, ZelioCom V2.08, ZelioAlarm 2 V1.5
PowerSuite v for drives V2.6 patch1
Libraries for Unity v Pro:
- TeSys, Fuzzy Control, HVAC, Predictive Control, Flow Calculation libraries
Application libraries for UAG and sg2: v
- Device & Process libraries
Alliance Software Packs References
Designation Description Reference Weight
kg
Alliance Software Pack
V1.0
For systems integrators
who are active partners
in the Alliance program
EUSENG1CFTAL10
Alliance Software Pack Pro
V1.0
For systems integrators
who are active partners
in the PlantStructure
Certied Alliance Partner
program.
EUSENG3CFTAL10
1
2
3
4
5
6
7
8
9
10
4/47
Vijeo Historian:
page 4/48
References (continued) Modicon M340
automation platform
Vijeo Citect
Supervisory control and data acquisition software (SCADA)
Vijeo Citect software Academic licenses
The references below are for educational institutions for training students in Vijeo
Citect software.
Training Manuals
Designation Reference Weight
kg
Vijeo Citect software Conguration
Training Manual - EN
VJC109310-02-00
Vijeo Citect software CICODE
Training Manual - EN
VJC109320-02-00
Vijeo Citect software Architecture and Redundancy
Training Manual - EN
VJC109330-02-00
Vijeo Citect software Upgrade
Training Manual - EN
VJC109350-02-00
Vijeo Citect software Customization
Training Manual - EN
VJC109370-02-00
Vijeo Citect software
Diagnostics and Troubleshooting Manual - EN
VJC109390-02-00
Self-Paced Training Kits
Designation Reference Weight
kg
Vijeo Citect software Conguration SPTK - EN VJC109310-01-00
Vijeo Citect software CICODE SPTK - EN VJC109320-01-000
Vijeo Citect software Customization SPTK - EN VJC109370-01-00
E-Learning
Designation Reference Weight
kg
Vijeo Citect software SCADA Overview VJC309331-00-00
Exams
Designation Reference Weight
kg
Vijeo Citect software Conguration Exam VJC309350-00-00
Vijeo Citect software CICODE Fundamentals Exam VJC309351-00-00
Vijeo Citect software Architecture and Redundancy Exam VJC309352-00-00
Vijeo Citect software Customization and Design Exam VJC309353-00-00
Vijeo Citect software Upgrade Exam VJC309354-00-00
Vijeo Citect software Examination Re-sit VJC309355-00-00
Vijeo Citect software Diagnostics and Troubleshooting
Exam
VJC309356-00-00
Academic Agreements
Designation Reference Weight
kg
Vijeo Citect software Academic Agreement
- 12 months (10 keys) (1)
VJC309317
Vijeo Citect software Academic Agreement
- 12 months renewal (10 keys) (1)
VJC309322
(1) Academic Agreements are to be included with each order for the Logistics team in Sydney to
process the order. Any incomplete orders (with no Academic Agreement) will be rejected.
This is only for tertiary education institutions. Licenses are valid for 12 months, each
agreement is renewed annually.
Vijeo Citect
1
2
3
4
5
6
7
8
9
10
4/48
Vijeo Citect:
page 4/34
Modicon M340
automation platform
Vijeo Historian reporting software
Introduction
Introduction
Vijeo Historian software is the information management component of
PlantStruxure, the new process automation architecture of Schneider Electric.
It is comprised of the historian and portal functions of the solution, enabling you to
store data accurately for long-term reporting while connecting your production and
business systems through its active data transfers and simple, easy-to-use reporting
functions.
Vijeo Historian software helps your plant and your IT personnel optimize their
operational efciency by providing a powerful enterprise-wide reporting tool that
collects, stores and delivers meaningful reporting data from multiple disparate
systems.
In addition, Vijeo Historian software enables you to store data accurately for
long-term reporting while also giving you the option of displaying and accessing the
information via the Vijeo Historian software portal, MS Excel or Reporting Services.
Vijeo Historian software architecture
Vijeo Historian
MS SQL
Oracle
Data sources Vijeo Historian software server SQL Server 2005
Vijeo Citect
software
OPC server
SCADA system
Company database
Task/event engine
Historian data service
Published data
Production
data Business
data Historic
data
Historian
Server portal
Historian
Web
server
(IIS)
Historian
conguration
database
Historian
database
Microsoft
Reporting
services
Report deployment
management
Report templates
Production data
Historic data
Conguration data
Report data
Business data
Project backup
Exported data
OPC HDA
server
Reports
Excel client Web Process
Analyst client
1
2
3
4
5
6
7
8
9
10
4/49
Vijeo Citect:
page 4/34
Modicon M340
automation platform
Vijeo Historian reporting software
Introduction (continued)
Applications
With Vijeo b Historian reporting software, business managers can access
meaningful, concise production system information from the plant oor in a familiar
format they use for their nancial or other business reports. This helps them make
strategic decisions to optimize operational performance.
Plant managers can drill down into information to improve production efciency or b
to minimize the number of spurious alarms.
Corporate and plant personnel can quickly and easily create and access b
meaningful reports in a familiar format and create a single view of operation.
Data sources supported
Vijeo Historian software supports the following data sources:
MS SQL (7.0, 2000, 2005) b
Oracle (7, 8, 9, 10) b
Vijeo b Citect software and other SCADA servers
Various other devices b
Vijeo Historian Web Client software and Excel Client software
Vijeo Historian software also provides two client tools to make it easier to view and
manage the information issued by the Historian Server:
Using the bWeb Client you can display plant information from your control systems
and the historian via the Intranet/Internet simply by using a browser such as Internet
Explorer.
The bExcel Client can also access linked information from the SCADA system or
the historian directly in Microsoft Excel. The Excel Client user can select from the
same plant hierarchy as the Web Client and request the values of any item within the
tree structure.
Security
Once logged on, users can only access the published folders, data and Favorites for
which they have permission.
Passwords are encrypted and user privileges are validated for every data request,
helping to ensure that users cannot bypass the security matrix.
License keys
The licenses are programmed on a USB or parallel key that is plugged into the PC
running the Vijeo Historian software.
1
2
3
4
5
6
7
8
9
10
4/50
Vijeo Citect:
page 4/34
Modicon M340
automation platform
Vijeo Historian reporting software
References
Development workshop
Description Type of key
included
Reference Weight
kg
Vijeo Historian software Box
USB key
USB VJH209922 _
Vijeo Historian software Box
Parallel key
Parallel VJH209912 _
Vijeo Historian software data transfer licenses
Description Number of points Reference Weight
kg
Vijeo Historian software
data transfer license
150 VJHNS211011
500 VJHNS211012
1500 VJHNS211013
5000 VJHNS211014
15000 VJHNS211015
50000 VJHNS211016
100000 VJHNS211045
Unlimited VJHNS211099
Vijeo Historian sofwtare data transfer upgrades
Description Number of points Reference Weight
kg
Vijeo Historian software data
transfer upgrade
150 to 500 VJHNS211011-12
500 to 1500 VJHNS211012-13
1500 to 5000 VJHNS211013-14
5000 to 15000 VJHNS211014-15
15000 to 50000 VJHNS211015-16
50000 to 100000 VJHNS211016-45
Unlimited VJHNS211045-99
Client access licenses
Description Reference Weight
kg
Client Historian and Portal access license VJHNS212400
Client Portal access license VJHNS212200
Client Historian access license VJHNS212000
References
Vijeo Historian
1
2
3
4
5
6
7
8
9
10
4/51
Vijeo Citect:
page 4/34
Modicon M340
automation platform
Vijeo Historian reporting software
References (continued)
Control system connector
Description Reference Weight
kg
MS SQL database connector
(1 per database system)
VJHNS204320
Oracle database connector
(1 per database system)
VJHNS204321
OPC DA V2 and V3 database connector
(1 per database system)
VJHNS204323
References (continued)
1
2
3
4
5
6
7
8
9
10
4/52
Modicon M340
automation platform
OPC data server software
OPC Factory Server (OFS)
Introduction
Based on the OLE for Process Control (OPC) standard, Schneider Electric's
OPC Factory Server (OFS) software allows “client” software applications, such as
supervisors/SCADA and customized interfaces, to access the data of Schneider
Electric automation system and electrical distribution devices connected to networks
or eldbuses in real time.
It also allows communication with third-party devices supporting Modbus and
Modbus/TCP protocols.
At the heart of the Transparent Ready offer, OFS enables simpler, more open and
transparent communication between your software applications and your devices.
These are just some of the advantages that help ensure an interoperable solution
that is central to your process.
In version V3.3, the OFS data server integrates the recent specications from the
OPC Foundation:
OPC-DA
b (OPC Data Access)
.NET API interface
b
OPC XML-DA V1.0
b (OPC XML Data Access)
The OFS V3.3 offer is available in two levels:
OFS Small:
b Data server for 1000 items (1) that does not support the
OPC XML-DA protocol
OFS Large:
b Complete data server
Devices and protocols supported
OFS software is a multi-device data server: it allows simultaneous use of several
communication protocols, and it provides client applications with a set of services for
accessing control system items that may be local or remote, via physical address or
via symbol.
Devices supported:
Modicon™ Quantum™, Premium™, M340™, Micro, Compact™ and Momentum™ PACs
b
Schneider Electric TSX Series 7 and April Series 1000 PACs
b
Modbus
b serial devices connected via Schneider Electric gateways: TSXETG
10pp, EGX ppp ranges, etc.
Uni-Telway
b serial devices connected via
Schneider Electric gateways (TSX ETG 1010)
Networks and protocols supported:
Modbus: Modbus serial, Modbus Plus, Modbus/TCP
b
X-Way
b /Uni-TE: Uni-Telway, FIPway, ISAway, PCIway
Openness
The development of specialized interfaces is simpler with OFS V3.3 software that is
aimed at two types of user in particular:
End users
b who want either to interface their supervision or Human Machine
Interface applications with Schneider Electric equipment, or to develop applications
on a PC (supervisory control screens, Excel tables, etc.) requiring access to control
system data.
Suppliers of control system or industrial data processing software
b
(supervision, Human Machine Interfaces, etc.) seeking to develop, within their
standard products, an OPC Client interface capable of accessing data in Schneider
Electric equipment via the OFS server.
(1) Item: A variable, structure, table, etc. in the Unity Pro application.
Introduction
OPC Factory Server
1
2
3
4
5
6
7
8
9
10
4/53
Supported architectures
The OFS server allows four access modes:
A purely local mode
b
Remote access from an OPC-DA client
b
Remote access from an OPC .NET client
b
Remote access from an OPC XML-DA client
b
Local access
The client application program and the OFS server are on the same PC.
Remote access from an OPC-DA client
The client application program and the OFS data server are on remote stations.
Communication between the client station and the OFS server is conducted through
the DCOM layer (Microsoft) via the OPC-DA protocol.
Modicon M340
automation platform
OPC data server software
OPC Factory Server (OFS)
Introduction (continued)
OPC Factory Server: home page
OFS station
Symbol data
(Unity Pro,
Concept or
PL7)
Modbus network X-Way network
Modicon
Premium
PAC
TSX Micro
Modicon
Momentum
I/O module
Modicon Quantum PAC
Local client
application
program
OFS station
Symbol data
(Unity Pro,
Concept or
PL7)
Modbus network X-Way network
Remote client
application
program
DCOM
Ethernet Modbus/TCP network
Local client
application
program
Modicon Quantum PAC
Modicon
Momentum
I/O module
Modicon
Premium
PAC
TSX Micro
1
2
3
4
5
6
7
8
9
10
4/54
Modicon M340
automation platform
OPC data server software
OPC Factory Server (OFS)
Supported architectures (continued)
Remote access from an OPC.NET client
The .NET client application program and the OFS data server are on remote
stations. Communication between the client station and the OFS server is conducted
through the DCOM layer (Microsoft) via the OPC-DA protocol.
The .NET Microsoft compatibility of the OFS server has been developed to allow an
OPC .NET client to access OFS server items on an Intranet network via the
OPC .NET API interface.
This interface helps ensure interoperability between existing OPC applications and
applications developed in the standard .NET environment.
Remote access from an OPC XML-DA client via HTTP
The client application program and the OFS server are on remote stations, using the
SOAP protocol to communicate via the Internet in conformity with the OPC XML-DA
V1.01 specication of the OPC Foundation.
The OFS data server is based on an HTTP server installed on the same station.
The OPC XML-DA V1.0 specications are designed to overcome the limitations of
COM/DCOM by providing:
An OPC interface for Windows and non-Windows client applications
b
Beyond the Intranet perimeter, remote access via the Internet through rewalls
b
The OPC XML-DA specication is based on Web Services standards such as SOAP,
XML and WSDL (1). A SOAP client can access data on the OFS server via Intranet or
Internet using the SOAP protocol in conformity with the OPC XML-DA V1.01
specication of the OPC Foundation.
(1) SOAP: Simple Object Access Protocol
XML: Extensible Markup Language
WSDL: Web Services Description Language
Server
OFS
station
Intranet
.NET client
Ethernet Modbus/TCP networkDCOM
Site server
and OFS
station
Symbol data
(Unity Pro,
Concept or PL7)
Industrial network IIS
Internet
Programmable
automation
controllers
Remote client
application
program
Firewall
Introduction (continued)
1
2
3
4
5
6
7
8
9
10
4/55
Modicon M340
automation platform
OPC data server software
OPC Factory Server (OFS)
Setup
The OFS server 1 is at the center of the data exchanges. It helps ensure that
variables exchanged between the OPC client 2 and the PAC 3 are consistent, in
one of three ways using a symbol (or variables) database:
The variables database is either the Unity b Pro project 4, or the Concept project.
In both these cases, Unity Pro or Concept needs to be installed on the OFS server
station.
The variables database is an export le (SCY for PL7, XVM for Unity Pro). PL7 b
and Unity Pro are not required in either of these cases.
The variables database is the PAC. In this case neither Unity Pro nor an export le b
is needed. The following minimum versions are required: OFS V3.33, Unity Pro
V4.1, PACs version V2.7 (Premium or Quantum) or V2.1 (M340). This does not
apply to Momentum and TSX Micro PACs.
If an inconsistency is detected (following online modication of the PAC program
for example), OFS resynchronizes automatically as soon as the database is
available again.
Setup
1
Ethernet Modbus/TCP
OFS server
(V3.0)
Database
Symbols.xvm (Unity Pro)
Symbols.prj (Concept)
Symbols.scy (PL7)
3 Modicon Premium PAC
3 TSX Micro PAC
3 Modicon Momentum
I/O module
3 Modicon Quantum PAC
Ethernet Modbus/TCP
4
Unity Pro
project
station
2 OPC client
1
2
3
4
5
6
7
8
9
10
4/56
Modicon M340
automation platform
OPC data server software
OPC Factory Server (OFS)
Functions
Development of client applications
OFS software has 4 types of interfaces:
OLE Automation interface (OPC-DA).
b
Particularly suitable for end users, this enables the development of OPC client
applications in Visual Basic, in Visual Basic for Excel, and in C++.
OLE Custom interface (OPC-DA).
b
Used primarily by suppliers of automated control system or industrial IT products, It
enables the development of applications in C++ to access the OFS software OPC
server. This interface is particularly aimed at software development experts, so that
they can integrate the client application into their standard products. This is the
interface offering the fastest times for accessing data stored in the OPC server. It
requires extensive knowledge of C++ programming to set up.
OPC .NET API wrapper interface
b
The .NET Microsoft compatibility of the OFS data server gives an OPC .NET client
standard access to items on the OFS server via an Intranet network, thus helping to
ensure greater interoperability with standard .NET environments.
Note: In this case, communication between the OPC .NET client and the OFS server is conducted
through the DCOM layer (or COM layer in a local conguration) via the OPC-DA protocol.
OPC XML-DA interface
b (1)
The OPC XML-DA V1.0 specications are designed to overcome the limitations of
the OPC-DA specication and COM/DCOM by providing:
An interface for Windows and non-Windows client applications v
Remote access via the Internet through rewalls (beyond the Intranet perimeter) v
The OPC XML-DA specication is based on Web Services standards such as SOAP,
XML, WSDL. A SOAP client can access data on the OFS server via Intranet or
Internet using the SOAP protocol in conformity with the OPC XML-DA V1.01
specication of the OPC Foundation.
(1) Only available with the Large version of OPC Factory Server V3.3
Functions
1
2
3
4
5
6
7
8
9
10
4/57
Modicon M340
automation platform
OPC data server software
OPC Factory Server (OFS)
References
OFS V3.3 software for PC compatible stations (minimum conguration:
Pentium 566 MHz processor, 128 MB RAM) running Windows 2000 Professional (1),
Windows XP Professional, Windows 7 (32-bit) (3), or Windows Server 2008 (3).
The OFS V3.3 offer is comprised of:
OPC
b server software
OPC server simulator (for debugging the application when no PACs are present)
b
OFS conguration software
b
Example of OPC client for conguring applications
b
Setup documentation on CD-ROM
b
Supplied on CD-ROM, the software operates independently on a PC. It interfaces
with the variables export les generated by PL7, ProWORX, Concept and Unity
Pro software.
It also provides a direct dynamic link to the Unity Pro and Concept applications (2).
OFS V3.3 software is available in two versions:
Small version
b TLX CD SpOFS 33
Maximum of 1000 items v
Supports any protocol except OPC XML-DA v
Single station and 10-station site licenses v
Large version
b TLX CD LpOFS 33
Full version v
Single station, 10-station and 200-station site licenses v
OPC Factory Server V3.3 Small
Description License type Reference Weight
kg
OPC Factory Server
V3.3 Small software
Single station TLXCDSUOFS33
10-station TLXCDSTOFS33
OPC Factory Server V3.3 Large
Description License type Reference Weight
kg
OPC Factory Server
V3.3 Large software
Full version
Single station TLXCDLUOFS33
10-station TLXCDLTOFS33
200-station TLXCDLFOFS33
(1) Updated with Service Pack 1 or higher
(2) Requires Concept software version 2.0 or later to be installed on the same station
(3) OFS is compatible with both these operating systems from version V3.34 or later.
References
OPC Factory Server
1
2
3
4
5
6
7
8
9
10
4/58
1
2
3
4
5
6
7
8
9
10
5/1
5.1 - Modicon Telefast ABE7 pre-wired system
Modicon Telefast ABE7 selection guide ...............................5/2
Interface with Modicon M340 I/O modules
b .............................5/8
References
b
Passive connection sub-bases
v ...................................5/12
Adaptor sub-bases with mounted relays and removable terminal blocks
v ...5/14
Input/output adaptor sub-bases
v for or with plug-in relays ...............5/15
Output adaptor sub-bases for plug-in relays
v .........................5/16
Plug-in relays
v ................................................5/17
Connection sub-bases for counter and analog channels
v ...............5/18
Accessories for connection sub-bases
v .............................5/19
5.2 - Phaseo power supplies and transformers
Regulated switch mode power supply selection guide .................5/20
Regulated switch mode power supplies: ABL8 range
b
Introduction
v .................................................5/22
Description
v ..................................................5/23
Combinations
v ................................................5/24
References
v .................................................5/25
Regulated switch mode power supplies: ABL4 range
b
Introduction
v .................................................5/26
Specications
v ................................................5/27
Description
v ..................................................5/28
References
v .................................................5/29
5.3 - Operator dialog terminals and HMI software
Operator dialog terminals selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . 5/30
HMI software selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5/36
Connection interfaces, regulated
switch mode power supplies,
Human/Machine interfaces
Contents chapter 5
1
2
3
4
5
6
7
8
9
10
5/2
Applications Discrete inputs or outputs Discrete inputs or outputs Outputs for solid state and/or electromechanical relays
Optimum “Economy” Optimum “Miniature” Universal Optimum “Miniature” Optimum and Universal
Compatibility TSX Micro, Modicon
Premium, Modicon
M340
TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340 TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340
Sub-base type Passive connection sub-bases Passive connection sub-bases Plug-in electromechanical or solid state relays
Equipped with relays No Yes
Control voltage 24 V c24 V c
Output voltage 24 V c24 V c24V c (solid state)
5 to 24 V c, 230 V a (electromechanical)
Output current per channel 0.5 A 0.5 A 0.5 A 5 A (E.M.), 2 A (solid state) 5 A (th)
Modularity 16 8 -12 -16 16 16
8 passive inputs
8 relay outputs
No. of terminals per channel 1 1 to 3 1 2 1 2 1
Type of connection terminals Signal Signal, common
(congurable as 24 V or
0 V c)
Signal Signal, common (congurable as 24 V or 0 V c) Signal,
2 common connections between the
inputs and the outputs.
Signal, common,
2 common connections between the
inputs and the outputs.
1 N/O contact and common, 4 output channels
2 input connection points
Connectors 20-way HE10 connector 20-way HE10 connectors
Terminal
block
Removable No No No
Type of
terminals
Screw Screw
Additional or optional*
function
Low-cost version tted
with cable
Miniature sub-bases Compact size *Input type 2 *
(1)
Isolator *Miniature sub-base
Synergy with Tego Power and Micro PAC
Miniature sub-base - Common per 4 channels
Synergy with Tego Power and Micro PAC
Type of device
ABE7HppEp00 ABE7H16Cpp ABE7HppR1p
ABE7HppR50
ABE7HppR2pABE7HppS21 ABE7H16CM11 ABE7H16CM21 ABE7P16M111 ABE7R16M111
Page 5/12 5/13 5/12 5/16 5/15
(1) For Modicon TSX Micro and Modicon Premium PACs.
Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Discrete input and/or output sub-bases
Selection guide
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
5/3
Applications Discrete inputs or outputs Discrete inputs or outputs Outputs for solid state and/or electromechanical relays
Optimum “Economy” Optimum “Miniature” Universal Optimum “Miniature” Optimum and Universal
Compatibility TSX Micro, Modicon
Premium, Modicon
M340
TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340 TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340
Sub-base type Passive connection sub-bases Passive connection sub-bases Plug-in electromechanical or solid state relays
Equipped with relays No Yes
Control voltage 24 V c24 V c
Output voltage 24 V c24 V c24V c (solid state)
5 to 24 V c, 230 V a (electromechanical)
Output current per channel 0.5 A 0.5 A 0.5 A 5 A (E.M.), 2 A (solid state) 5 A (th)
Modularity 16 8 -12 -16 16 16
8 passive inputs
8 relay outputs
No. of terminals per channel 1 1 to 3 1 2 1 2 1
Type of connection terminals Signal Signal, common
(congurable as 24 V or
0 V c)
Signal Signal, common (congurable as 24 V or 0 V c) Signal,
2 common connections between the
inputs and the outputs.
Signal, common,
2 common connections between the
inputs and the outputs.
1 N/O contact and common, 4 output channels
2 input connection points
Connectors 20-way HE10 connector 20-way HE10 connectors
Terminal
block
Removable No No No
Type of
terminals
Screw Screw
Additional or optional*
function
Low-cost version tted
with cable
Miniature sub-bases Compact size *Input type 2 *
(1)
Isolator *Miniature sub-base
Synergy with Tego Power and Micro PAC
Miniature sub-base - Common per 4 channels
Synergy with Tego Power and Micro PAC
Type of device
ABE7HppEp00 ABE7H16Cpp ABE7HppR1p
ABE7HppR50
ABE7HppR2pABE7HppS21 ABE7H16CM11 ABE7H16CM21 ABE7P16M111 ABE7R16M111
Page 5/12 5/13 5/12 5/16 5/15
(1) For Modicon TSX Micro and Modicon Premium PACs.
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
5/4
Applications Discrete outputs Discrete outputs Discrete inputs or outputs
Optimum Universal Optimum Universal Universal Universal
Compatibility TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340
Relay sub-base Electromechanical, mounted Electromechanical or solid state Electromechanical, plug-in Solid state,
mounted
Solid state,
mounted
Solid state,
plug-in
Equipped with relays Yes Yes No No Yes Yes Yes No
Control voltage 24 V c24 V cFrom 24 V c
to 230 V aFrom 5 V TTL
to 230 V a
Output voltage 5 V to 30 V c
230 V a5 V to 150 V c
230 V a24 V c (solid state)
5 V to 24 V c, 230 V a (E.M.)
5 V to 150 V c
230 V a5 V to 150 V c
230 V a24 V c
Output current per channel 2 A (th) 3 A (th) 5 A (th) 2 A (solid state)
6 A (electromechanical)
0.5 to 10 A
(dependent on
relay)
5 A (th) 8 A (th) 0.5 to 2 A 125 mA 0.5 A 125 mA 12 mA
Modularity 8 8 - 16 16 8 or 16 16
No. of terminals per channel 2 1 2 1 2 to 3 2 to 3 2 to 6 2 3 2
Type of connection terminals 1 N/O contact and
common
Volt-free
1 N/O contact 1 N/O contact and
common
1 N/O contact Signal, Polarities 1 C/O contact or 1 N/O
contact and common
1 C/O contact or
2 C/O contacts
and common
Signal and 0 V 24 V and 0 V c
signal
Signal can be
isolated,
Protected
common
Signal Signal and
common
Connectors 20-way HE 10 connector 20-way HE 10 connector
Terminal
block
Removable Yes Yes Yes No No No Yes No No Yes No
Terminal type Screw or spring Screw Screw Screw or spring Screw Screw or spring
Additional or optional*
function
Miniature sub-base
Latching relay
Volt-free or common per group of 8
channels
Miniature sub-bases
Common per group of 4 channels
Isolator and fuse Volt-free or common per group of: Detected fault
signal
Isolator and fuse
(indicator)
3-wire proximity
sensor
Isolator and fuse
(indicator)
8 channels 4 channels
Type of device
ABE7R08S216pABE7RppS1pp ABE7RppS2pp ABE7R16T111 ABE7P16T111 ABE7P16T2ppp
ABE7P08T3ppp
ABE7R16T2pp ABE7R16T3pp ABE7SppS2BpABE7H16F43 ABE7H16R3pABE7H16S43 ABE7S16E2ppE ABE7P16F31p
Page 5/14 5/15 5/16 5/15 5/14 5/13 5/14 5/15
(1) For TSX Micro and Modicon Premium PACs
Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Discrete input and/or output sub-bases
Selection guide (continued)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
5/5
Applications Discrete outputs Discrete outputs Discrete inputs or outputs
Optimum Universal Optimum Universal Universal Universal
Compatibility TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340TSX Micro, Modicon Premium, Modicon Quantum, Modicon M340
Relay sub-base Electromechanical, mounted Electromechanical or solid state Electromechanical, plug-in Solid state,
mounted
Solid state,
mounted
Solid state,
plug-in
Equipped with relays Yes Yes No No Yes Yes Yes No
Control voltage 24 V c24 V cFrom 24 V c
to 230 V aFrom 5 V TTL
to 230 V a
Output voltage 5 V to 30 V c
230 V a5 V to 150 V c
230 V a24 V c (solid state)
5 V to 24 V c, 230 V a (E.M.)
5 V to 150 V c
230 V a5 V to 150 V c
230 V a24 V c
Output current per channel 2 A (th) 3 A (th) 5 A (th) 2 A (solid state)
6 A (electromechanical)
0.5 to 10 A
(dependent on
relay)
5 A (th) 8 A (th) 0.5 to 2 A 125 mA 0.5 A 125 mA 12 mA
Modularity 8 8 - 16 16 8 or 16 16
No. of terminals per channel 2 1 2 1 2 to 3 2 to 3 2 to 6 2 3 2
Type of connection terminals 1 N/O contact and
common
Volt-free
1 N/O contact 1 N/O contact and
common
1 N/O contact Signal, Polarities 1 C/O contact or 1 N/O
contact and common
1 C/O contact or
2 C/O contacts
and common
Signal and 0 V 24 V and 0 V c
signal
Signal can be
isolated,
Protected
common
Signal Signal and
common
Connectors 20-way HE 10 connector 20-way HE 10 connector
Terminal
block
Removable Yes Yes Yes No No No Yes No No Yes No
Terminal type Screw or spring Screw Screw Screw or spring Screw Screw or spring
Additional or optional*
function
Miniature sub-base
Latching relay
Volt-free or common per group of 8
channels
Miniature sub-bases
Common per group of 4 channels
Isolator and fuse Volt-free or common per group of: Detected fault
signal
Isolator and fuse
(indicator)
3-wire proximity
sensor
Isolator and fuse
(indicator)
8 channels 4 channels
Type of device
ABE7R08S216pABE7RppS1pp ABE7RppS2pp ABE7R16T111 ABE7P16T111 ABE7P16T2ppp
ABE7P08T3ppp
ABE7R16T2pp ABE7R16T3pp ABE7SppS2BpABE7H16F43 ABE7H16R3pABE7H16S43 ABE7S16E2ppE ABE7P16F31p
Page 5/14 5/15 5/16 5/15 5/14 5/13 5/14 5/15
(1) For TSX Micro and Modicon Premium PACs
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
5/6
Applications Analog signals and special functions Analog signals and special functions
Compatibility TSX Micro:
TSX3722,
TSXCTZpA
Modicon Premium:
TSXCTYpA,
TSXCAYp1
Modicon Premium:
TSXASY810,
TSXAE1600,
TSXApY800
Modicon M340:
BMXAMI0800,
BMXAMI0810,
BMXAMO0802
Modicon Premium:
TSXASY410,
TSXAEY420
Modicon M340:
BMXAMO0410
Modicon M340:
BMXART0414,
BMXART0814
Modicon Premium:
TSXAEY1614
Modicon Premium:
TSXAEY800,
TSXAEY1600
Modicon Premium: TSXAEY810
Modicon M340:
BMXAMI0800,
BMXAMI0810,
BMXAMO0802
Modicon Premium: TSXCAYp1,
TSXCTYpA
Modicon Premium:
TSXAEY1614
Modicon Premium:
TSXPAY2p2
Type of signal Counter inputs and
analog I/O
Counter inputs
Axis control
Position control
Analog inputs
Current/Voltage
Pt 100
Analog outputs
Current
Voltage
Analog inputs Analog inputs
Current
Voltage
Pt 100
Isolated analog inputs Counter inputs Inputs for thermocouples Inputs/outputs
Functions Passive connection, point-to-point with shield continuity Connection of cold junction
compensation or provision,
distribution of isolated
power supplies
Distribution of sensor power
supplies per limiter
(25 mA)
Distribution of isolated sensor
power supplies per converter
Acquisition of value from an
absolute encoder
Connection of 16
thermocouples with cold
junction compensation
Safety module (BG)
Modularity 1 counter channel or
8 analog inputs + 2 analog outputs
8 channels 4 channels 4 channels 8 channels 8 channels 1 channel 16 channels 12 Emergency stops
Control voltage 24 V c 24 V c
Output voltage 24 V c 24 V c
Output current per channel 25 mA 25 mA
No. of terminals per channel 2 2 or 4 2 or 4 2 or 4 2 or 4 2 or 4 1
Type of connector 15-way SUB-D + 9-way SUB-D 25-way SUB-D 25-way SUB-D 25-way SUB-D 25-way SUB-D 15-way SUB-D 25-way SUB-D 50-way SUB-D
Terminal
block
Removable No No No No No No No No
Type of
terminals
Screw Screw Screw Screw Screw or spring Screw Screw Screw
Type of device
ABE7CPA01 ABE7CPA02 ABE7CPA21 ABE7CPA412
ABE7CPA410
ABE7CPA03 ABE7CPA31pABE7CPA11 ABE7CPA12 ABE7CPA13
Page 5/18 5/18
Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Analog and application-specic sub-bases
Selection guide (continued)
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
5/7
Applications Analog signals and special functions Analog signals and special functions
Compatibility TSX Micro:
TSX3722,
TSXCTZpA
Modicon Premium:
TSXCTYpA,
TSXCAYp1
Modicon Premium:
TSXASY810,
TSXAE1600,
TSXApY800
Modicon M340:
BMXAMI0800,
BMXAMI0810,
BMXAMO0802
Modicon Premium:
TSXASY410,
TSXAEY420
Modicon M340:
BMXAMO0410
Modicon M340:
BMXART0414,
BMXART0814
Modicon Premium:
TSXAEY1614
Modicon Premium:
TSXAEY800,
TSXAEY1600
Modicon Premium: TSXAEY810
Modicon M340:
BMXAMI0800,
BMXAMI0810,
BMXAMO0802
Modicon Premium: TSXCAYp1,
TSXCTYpA
Modicon Premium:
TSXAEY1614
Modicon Premium:
TSXPAY2p2
Type of signal Counter inputs and
analog I/O
Counter inputs
Axis control
Position control
Analog inputs
Current/Voltage
Pt 100
Analog outputs
Current
Voltage
Analog inputs Analog inputs
Current
Voltage
Pt 100
Isolated analog inputs Counter inputs Inputs for thermocouples Inputs/outputs
Functions Passive connection, point-to-point with shield continuity Connection of cold junction
compensation or provision,
distribution of isolated
power supplies
Distribution of sensor power
supplies per limiter
(25 mA)
Distribution of isolated sensor
power supplies per converter
Acquisition of value from an
absolute encoder
Connection of 16
thermocouples with cold
junction compensation
Safety module (BG)
Modularity 1 counter channel or
8 analog inputs + 2 analog outputs
8 channels 4 channels 4 channels 8 channels 8 channels 1 channel 16 channels 12 Emergency stops
Control voltage 24 V c 24 V c
Output voltage 24 V c 24 V c
Output current per channel 25 mA 25 mA
No. of terminals per channel 2 2 or 4 2 or 4 2 or 4 2 or 4 2 or 4 1
Type of connector 15-way SUB-D + 9-way SUB-D 25-way SUB-D 25-way SUB-D 25-way SUB-D 25-way SUB-D 15-way SUB-D 25-way SUB-D 50-way SUB-D
Terminal
block
Removable No No No No No No No No
Type of
terminals
Screw Screw Screw Screw Screw or spring Screw Screw Screw
Type of device
ABE7CPA01 ABE7CPA02 ABE7CPA21 ABE7CPA412
ABE7CPA410
ABE7CPA03 ABE7CPA31pABE7CPA11 ABE7CPA12 ABE7CPA13
Page 5/18 5/18
See more technical information online at www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
5/8
Introduction Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Interface with Modicon M340 I/O modules
(1) Connection of the 24 V c power supply is only possible using Modicon Telefast ABE7 sub-bases. The 0 V c connections are required to be equipotential.
Q8 Q9 Q10 Q11 Q12 Q13 Q14 Q15
+24Vdc 0Vdc
Fus I = 1A max
LC
Q0 Q1 Q2 Q3
ABE7P16T214
16 Relays Outputs
Q4 Q5 Q6 Q7
200
201
202
203
204
205
206
207
100
101
102
103
104
105
106
107
1
2
5
6
3
4
7
8
208
209
210
211
212
213
214
215
108
109
110
111
112
113
114
115
1
2
2
6
3
3
4-b
7
2
2
5
11
1-b
c 24 V (1)
c 24 V (1)
c 24 V (1)
Ch0 Ch2 Ch3Ch4
4-c
1-c
Analog
16 channels
Sub-base for
2/4/8 analog
channels
Sub-base for
8 discrete I/O
Sub-base for
16 discrete
I/O
Sub-base for
16 discrete
I/O
16 channels
16 channels 16 channels
2 x 8
channels
2/4/8 channels
Discrete Discrete
1
2
3
4
5
6
7
8
9
10
5/9
Introduction
I/O modules on the Modicon M340 platform
Discrete input modules (BMXDDI 1 pp02K), discrete output modules
(BMXDDO pp02K) and discrete mixed I/O modules (BMXDDM3202K) equipped
with one or two 40-way FCN connectors. The modularity of each module (pp) is
32 or 64 channels.
1-b:
v Analog input or output modules:
Analog inputs: - BMXAMI0410 (4 channels), BMXAMI0800 (4 channels) and
BMXAMI0810 (8 channels)
Analog outputs: - BMXAMO0210 (2 channels), BMXAMO0410 (4 channels)
and BMXAMO0802 (8 channels)
1-c:
v Analog input modules BMXART0414 (4 channels) and BMXART0814
(8 channels)
2 types of cordset are available depending on the type of discrete module 2
connected to the sub-base (for combinations, see page 5/10). These cordsets
are available in 0.5, 1, 2, 3, 5 or 10 m lengths:
BMXFCC -ppp1 cordsets with one 20-wire sheath (AWG 22) equipped with
one 40-way FCN connector and one HE 10 molded connector on the
Telefast sub-base end
BMXFCC -ppp3 cordsets with two 20-wire sheaths (AWG 22) equipped with
one common 40-way FCN connector on the module end and two HE 10
molded connectors on the Telefast sub-base end
16-channel Modicon Telefast ABE7 Optimum or Universal passive connection 3
sub-bases or adaptor sub-bases.
4 types of cordset are available depending on the type of analog module 4
connected to the sub-base (for combinations, see page 5/11).
4-b:
v Connection to analog module with removable terminal block 20-way
or 28-way:
BMXFCA -pp0 cordsets with a 20-way removable terminal block on the
module end and a 25-way SUB-D connector on the Telefast sub-base end
Cordsets available in 1.5, 3 or 5 m lengths.
BMXFTA -pp2 cordsets with a 20-way removable terminal block on the
module end and a 25-way SUB-D connector on the Telefast sub-base end
Cordsets available in 1.5 or 3 m lengths.
BMXFTA -pp0 cordsets with a 28-way removable terminal block on the
module end and a 25-way SUB-D connector on the Telefast sub-base end
Cordsets available in 1.5 or 3 m lengths.
4-c
v : Connection to analog module with 40-way FCN connector:
BMXFCA -pp2 cordsets with a 40-way FCN connector on the module end
and a 25-way SUB-D connector on the Telefast sub-base end Cordsets
available in 1.5, 3 or 5 m lengths.
Modicon Telefast ABE7CPA analog and application-specic connection 5
sub-bases (for combinations, see pages 5/11):
ABE7CPA410 - allows connection on a screw terminal block of 4 current/
voltage inputs, with provision and distribution of 4 isolated protected power
supplies for the current loop inputs
ABE7CPA412 - allows connection on a screw terminal block of 4
thermocouple inputs, with supply of cold-junction compensation for these
inputs
ABE7CPA21 - allows connection on a screw terminal block of 4 current/
voltage outputs
ABE7CPA02 - allows connection on a screw terminal block of 8 current/
voltage I/O
ABE7CPA03 - allows connection on a screw terminal block of 8 inputs, with
provision and distribution of the power supply (with limitation of each current
loop) for the current/voltage outputs of the BMXAMO0210 analog module
ABE7CPA31/31E - allows connection on a screw terminal block
(ABE7CPA31) or a spring-type terminal block (ABE7CPA31E) of 8 inputs,
with provision and distribution of the power supply (limited to 25 mA per
input)
ABE7ACC026 sub-base for splitting 16 into 2 x 8 channels, allowing connection
of 8-channel sub-bases.
8-channel Modicon Telefast ABE7 Optimum or Universal passive connection 7
sub-bases or adaptor sub-bases.
Introduction (continued) Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Interface with Modicon M340 I/O modules
1
2
3
4
5
6
7
8
9
10
5/10
Combinations of discrete inputs/outputs on the Modicon M340 platform with ABE7 sub-bases.
(items 1 to 7), see Introduction on page 5/8 Discrete I/O modules on the Modicon M340 platform
Reference for 24 V c discrete I/O modules (item 1)
Inputs Outputs Inputs/outputs
2 x 16 I 4 x 16 I 2 x 16 Q 4 x 16 Q 1 x 16 I, 1 x 16 Q
BMXDDI3202K BMXDDI6402K BMXDDO3202K BMXDDO6402K BMXDDM3202K
Required cordsets
Pre-assembled
cordsets
(at both ends)
BMXFCCpp1/FCCpp3 (item 2) (1) Yes Yes Yes Yes No
BMXFCCpp3 (item 2) (1) No No No No Yes
Quantities to be ordered 1 2 1 2 1
Passive connection sub-bases
Optimum 16
channels
(item 3)
ABE7H34Ep00 “economy” (2)
ABE7H16Cpp “miniature”
Universal 8
channels
(item 7)
ABE7H08Rpp (3) (3) (3) (3) (3)
ABE7H08S21 (3) (3) (3) (3) (3)
Universal 16
channels
(item 3)
ABE7H16R1pp
ABE7H16R50p
ABE7H16R2pp
ABE7H16S21p
ABE7H16R3p
ABE7H16R23
ABE7H16S43
ABE7H16F43
Input adaptor sub-bases with solid state relays
Universal 16
channels
(item 3)
ABE7S16E2ppp
Mounted solid state relays, removable terminal
blocks
ABE7P16F31p
Plug-in solid state relays
Output adaptor sub-bases with mounted relays, removable terminal blocks
Optimum &
Universal 8
channels
(item 7)
ABE7S08S2Bpp
Solid state relays
(3) (3) (3)
ABE7R08S111p/7R08S21pp
Electromechanical relays
(3) (3) (3)
Optimum &
Universal 16
channels
(item 3)
ABE7S16SpBpp
Solid state relays
ABE7R16S111p/7R16S21pp
Electromechanical relays
Output adaptor sub-bases with plug-in relays
Universal 8
channels
(item 7)
ABE7P08T330p
Solid state relays
(3) (3) (3)
Optimum &
Universal 16
channels
(item 3)
ABE7R16Tppp/7R16M111
Electromechanical relays
ABE7P16Tppp/7P16M111
Solid state and/or electromechanical relays
Sub-bases for analog I/O
4 channels
(item 5)
ABE7CPA410
ABE7CPA412
2 channels
(item 5)
ABE7CPA21
8 channels
(item 5)
ABE7CPA02
ABE7CPA03
ABE7CPA31/31E
Compatible
Not compatible
(1) References for cordsets: to be completed, see page 2/13.
(2) ABE7H34Ep00 “economy” sub-bases: the cordset is supplied.
(3) Via the splitter sub-base 6 ABE7ACC02 used to separate 16 channels into 2 x 8 channels
Combinations Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Modicon M340 I/O modules with ABE7 sub-bases
1
2
3
4
5
6
7
8
9
10
5/11
Combinations (continued) Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
ABE7 interfaces with Modicon M340 I/O modules
Combinations of analog inputs/outputs on the Modicon M340 platform with ABE7 sub-bases
(items 1 to 7), see Introduction on page 5/8 Analog I/O modules on the Modicon M340 platform
Reference for analog I/O modules (item 1-b and 1-c)
Inputs Outputs
4 I 4 I 2 x 4 I 8 I 8 I 2 Q 4 Q 8 Q
BMXAMI
0410
BMXART
0414
BMX ART
0814
BMXAMI
0800
BMXAMI
0810
BMXAMO
0210
BMXAMO
0410
BMXAMO
0802
Required cordsets
Pre-assembled
cordsets
(at both ends)
BMXFCApp0 (item 4-b) (1) Yes No No No No Yes Yes No
BMXFCApp2 (item 4-c) (1) No Yes Yes No No No No Yes
BMXFTApp0 (item 4-c) (1) No No No Yes Yes No Yes No
BMXFTApp2 (item 4-c) (1) No No No No No No No Yes
Quantities to be ordered 1 1 2 1 1 1 1 1
Passive connection sub-bases
Optimum 16
channels
(item 3)
ABE7H34Ep00 “economy” (2)
ABE7H16Cpp “miniature”
Universal 8
channels
(item 7)
ABE7H08Rpp
ABE7H08S21
Universal 16
channels
(item 3)
ABE7H16R1pp
ABE7H16R50p
ABE7H16R2pp
ABE7H16S21p
ABE7H16R3p
ABE7H16R23
ABE7H16S43
ABE7H16F43
Input adaptor sub-bases with solid state relays
Universal 16
channels
(item 3)
ABE7S16E2ppp
Mounted solid state relays, removable terminal
blocks
ABE7P16F31p
Plug-in solid state relays
Output adaptor sub-bases with mounted relays, removable terminal blocks
Optimum &
Universal 8
channels
(item 7)
ABE7S08S2Bpp
Solid state relays
ABE7R08S111p/7R08S21pp
Electromechanical relays
Optimum &
Universal 16
channels
(item 3)
ABE7S16SpBpp
Solid state relays
ABE7R16S111p/7R16S21pp
Electromechanical relays
Output adaptor sub-bases with plug-in relays
Universal 8
channels
(item 7)
ABE7P08T330p
Solid state relays
Optimum &
Universal 16
channels
(item 3)
ABE7R16Tppp/7R16M111
Electromechanical relays
ABE7P16Tppp/7P16M111
Solid state and/or electromechanical relays
Sub-bases for analog I/O
4 channels
(item 5)
ABE7CPA410
ABE7CPA412
2 channels
(item 5)
ABE7CPA21
8 channels
(item 5)
ABE7CPA02
ABE7CPA03
ABE7CPA31/31E
Compatible
Not compatible
(1) References for cordsets: to be completed, see page 2/23.
(2) ABE7H34Ep00 “economy” sub-bases: the cordset is supplied.
1
2
3
4
5
6
7
8
9
10
5/12
Passive connection sub-bases for discrete signals
Optimum "Economy" sub-bases
Function No. of
channels
No. of terminals For PACs Length of
PAC
connection
cable
Type of
connection
Reference Weight
kg
per
channel
on row
number
Input or output 16 1 2 Modicon TSX
Micro
Modicon Premium
1 m Screw ABE7H20E100 0.330
2 m Screw ABE7H20E200 0.410
3 m Screw ABE7H20E300 0.480
Modicon M340(1) Screw ABE7H34E000 0.150
1 m Screw ABE7H34E100 0.330
2 m Screw ABE7H34E200 0.410
3 m Screw ABE7H34E300 0.480
Siemens S7 1.5 m Screw ABE7H32E150 0.360
3 m Screw ABE7H32E300 0.460
Optimum "Miniature" sub-bases
Function No. of
channels
No. of terminals LED per channel Polarity
distribution
Type of
connection
Reference Weight
kg
per
channel
on row
number
Input or output 16 1 1 No No Screw ABE7H16C10 0.160
Yes No Screw ABE7H16C11 0.160
2 2 Yes 0 or 24 V Screw ABE7H16C21 0.205
3 3 Yes 0 or 24 V Screw ABE7H16C31 0.260
Input and output
(2)
16 1 1 Yes No Screw ABE7H16CM11 0.160
2 2 Yes 0 or 24 V Screw ABE7H16CM21 0.200
(1) Sub-base supplied without cordset.
(2) 8 I + 8 Q: these products have 2 common connections that enable inputs and outputs to be connected to the same
sub-base at the same time.
Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Passive connection sub-bases
References
ABE7H20Eppp
ABE7H16CM21
ABE7H16C21
1
2
3
4
5
6
7
8
9
10
5/13
Passive connection sub-bases for discrete signals (continued)
Universal sub-bases
Function No. of
channels
No. of terminals LED per
channel
Polarity
distribution
Isolator (I)
Fuse (F)
per channel
Type of
connection
Reference Weight
kg
per
channel
on row
number
Input or output 8 1 1 No No Screw ABE7H08R10 0.187
Yes No Screw ABE7H08R11 0.187
2 2 Yes 0 or 24 V Screw ABE7H08R21 0.218
I Screw ABE7H08S21 0.245
12 1 1 No No Screw ABE7H12R10 0.274
Yes No Screw ABE7H12R11 0.274
2 No No Screw ABE7H12R50 0.196
2 2 No 0 or 24 V Screw ABE7H12R20 0.300
Yes 0 or 24 V Screw ABE7H12R21 0.300
I Screw ABE7H12S21 0.375
16 1 1 No No Screw ABE7H16R10 0.274
Yes No Screw ABE7H16R11 0.274
2 No No Screw ABE7H16R50 0.196
2 2 No 0 or 24 V Screw ABE7H16R20 0.300
Yes 0 or 24 V Screw ABE7H16R21 0.300
I Screw ABE7H16S21 0.375
3 3 No 0 or 24 V Screw ABE7H16R30 0.346
Yes 0 or 24 V Screw ABE7H16R31 0.346
Input type 2 (1) 16 2 2 Yes 0 or 24 V Screw ABE7H16R23 0.320
Input 16 2 1 Yes 24 V I, F (2) Screw ABE7H16S43 0.640
Output 16 2 1 Yes 0 V I, F (2) Screw ABE7H16F43 0.640
(1) For TSX Micro, Modicon Premium.
(2) With LED to indicate open fuse.
Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Passive connection sub-bases
References (continued)
ABE7HppR1p
1
2
3
4
5
6
7
8
9
10
5/14
Adaptor sub-bases with mounted solid state relays, removable terminal blocks
Universal input sub-bases with solid state relays
Number of
channels
No. of
terminals
per channel
Isolation of PAC/
Operative part
Voltage Type of
connection
Reference Weight
kg
16 2 Yes c 24 V Screw ABE7S16E2B1 0.370
Spring ABE7S16E2B1E 0.370
c 48 V Screw ABE7S16E2E1 0.370
a 48 V Screw ABE7S16E2E0 0.386
a 110 V Screw ABE7S16E2F0 0.397
a 230 V Screw ABE7S16E2M0 0.407
Spring ABE7S16E2M0E 0.407
Universal output sub-bases with solid state relays
Number of
channels
Isolation of
PAC/
Operative
part
Output
voltage
Output
current
Fault detection
signal (1)
Type of
connection
Reference Weight
kg
16 No 24 V c0.5 A Yes (2) Screw ABE7S16S2B0 0.405
Spring ABE7S16S2B0E 0.405
No Screw ABE7S16S1B2 0.400
Spring ABE7S16S1B2E 0.400
Optimum and Universal output sub-bases with electromechanical relays
Number of
channels
Number of contacts Output
current
Polarity
distribution/
operative part
Type of
connection
Reference Weight
kg
81 N/O 2 A Contact common
per group of 4
channels
Screw ABE7R08S111 0.252
Latching 2 A Volt-free Screw ABE7R08S216 0.448
1 N/O 5 A Volt-free Screw ABE7R08S210 0.448
16 1 N/O 2 A Contact common
per group of 8
channels
Screw ABE7R16S111 0.405
Spring ABE7R16S111E 0.405
1 N/O 5 A Volt-free Screw ABE7R16S210 0.405
Spring ABE7R16S210E 0.405
Common per
group of 8
channels on both
poles
Screw ABE7R16S212 0.400
(1) A detected fault on a sub-base output Qn will set PAC output Qn to safe mode that will be detected by the PAC.
(2) Can only be used with modules with protected outputs.
Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system: Adaptor
sub-bases w/ mounted relays, removable terminal blocks
References (continued)
ABE7R08S216
ABE7H16E2pp
1
2
3
4
5
6
7
8
9
10
5/15
Adaptor sub-bases with plug-in relays
Universal input sub-bases for solid state relays, supplied without relays
Number of
channels
No. of
terminals
per channel
For relay type Isolation of
PAC/
Operative
part
Input
connection
Type of
connection
Reference Weight
kg
16 2 ABS7E
ABR7
ABS7S33E
Yes Volt-free Screw ABE7P16F310 0.850
Polarity
distribution
Screw ABE7P16F312 0.850
Optimum and Universal output sub-bases, supplied with electromechanical relays (1)
Number of
channels
Relay width Relay type
supplied
Number and
type of
contacts
Polarity distribution/operative
part
Reference Weight
kg
16 5 mm ABR7S11 1 N/O Contact common per group of 4
channels
ABE7R16T111 0.600
Contact common per group of 4
output channels
+ 2 common input terminals
ABE7R16M111
(2)
0.600
10 mm ABR7S21 1 N/O Volt-free ABE7R16T210 0.735
Common on both poles (3) ABE7R16T212 0.730
ABR7S23 1 C/O Volt-free ABE7R16T230 0.775
Contact common (3) ABE7R16T231 0.730
12 mm ABR7S33 1 C/O Volt-free ABE7R16T330 1.300
Common on both poles (4) ABE7R16T332 1.200
ABR7S37 2 C/O Volt-free ABE7R16T370 1.300
(1) The sub-bases are supplied as standard with electromechanical relays that can be replaced by solid state relays of the
same width (it is possible to combine these different technologies on a single sub-base).
(2) Two connection methods are available, enabling inputs and outputs to be connected
to the same sub-base at the same time.
(3) Per group of 8 channels.
(4) Per group of 4 channels.
Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Input/output adaptor sub-bases for or with plug-in relays
References (continued)
ABE7R16M111
ABE7R16T210
1
2
3
4
5
6
7
8
9
10
5/16
Output adaptor sub-bases for plug-in relays
Optimum and Universal output sub-bases for solid state relays and/or electromechanical relays (1)
No. of
channels
Relay
width
For relay type Isolator
per
channel
Fuse per
channel
Polarity distribution/
operative part
Type of
connection
Reference Weight
mm kg
16 5 mm ABR7S11
ABS7SC1B
No No Contact common per
group of 4 channels
Screw ABE7P16T111 0.550
10 mm ABR7S2p
ABS7SA2p
ABS7SC2p
ABE7ACC20
No No Volt-free Screw ABE7P16T210(2) 0.615
ABE7P16T230(2) 0.655
Yes Volt-free Screw ABE7P16T214 0.675
No Common on both poles
(3)
Screw ABE7P16T212 0.615
Yes Common on both poles
(3)
Screw ABE7P16T215 0.670
812 mm ABR7S33
ABS7A3p
ABS7SC3pp
ABE7ACC21
No No Volt-free Screw ABE7P08T330 0.450
16 12 mm ABR7S33
ABS7A3p
ABS7SC3pp
ABE7ACC21
No No Volt-free Screw ABE7P16T330 0.900
Common on both poles
(4)
Screw ABE7P16T332 0.900
ABR7S33
ABS7A3M
ABS7SC3E
ABE7ACC21
No Yes Volt-free Screw ABE7P16T334 0.900
Yes Yes Common on both poles
(4)
Screw ABE7P16T318 1.000
(1) Not equipped with relays.
(2) With relay ABR7S21 for sub-base ABE7P16T210, with relay ABR7S23 for sub-base ABE7P16T230p.
(3) Per group of 8 channels.
(4) Per group of 4 channels.
Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Output adaptor sub-bases for plug-in relays
References (continued)
ABE7P16T2pp
1
2
3
4
5
6
7
8
9
10
5/17
Plug-in solid state relays
Relay width Functions Input circuit Output circuit Unit reference
Order in multiples
of 4
Weight
kg
Current Nominal
voltage
Current Nominal
voltage
5 mm Output c 24 V 2 A 24 V cABS7SC1B 0.010
10 mm Output c 24 V 0.5 A 5 to 48 V cABS7SC2E 0.016
24 to 240 V aABS7SA2M 0.016
12 mm Input c 5 V TTL 24 V cABS7EC3AL 0.014
24 V Type 2 24 V cABS7EC3B2 0.014
48 V Type 2 24 V cABS7EC3E2 0.014
50 Hz a48 V 24 V cABS7EA3E5 0.014
60 Hz a110 to 130 V 24 V cABS7EA3F5 0.014
50 Hz a230 to 240 V 24 V cABS7EA3M5 0.014
Output c 24 V 2 A
Self-protected
24 V cABS7SC3BA 0.016
1.5 A 5 to 48 V cABS7SC3E 0.016
1.5 A 24 to 240 V aABS7SA3MA 0.016
Plug-in electromechanical relays
Relay width Control
voltage
Output current
(1)
Number of
contacts
Order in
multiples
Unit reference Weight
kg
5 mm 24 V c5 A (Ith) 1 N/O 4ABR7S11 0.005
10 mm 24 V c5 A (Ith) 1 N/O 4ABR7S21 0.008
1 C/O 4ABR7S23 0.008
12 mm 2 V c10 A (Ith) 1 C/O 4ABR7S33 0.017
8 A (Ith) 2 C/O 4ABR7S37 0.017
48 V c8 A (Ith) 1 C/O 4ABR7S33E 0.017
Accessory
Description Reference Weight
kg
Extractor for 5 mm miniature relay ABE7ACC12 0.010
Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Plug-in relays
ABS7SC1B
ABR7S2p
ABR7S3p
References (continued)
1
2
3
4
5
6
7
8
9
10
5/18
Connection sub-bases for counter and analog channels
Functions For PACs Compatible
modules
Type of
connector on
Telefast end
Type of
connection
Reference Weight
kg
Counter and analog
channels
TSX MicroIntegrated
analog and
counting
functions
TSX3722
TSXCTZpA
15-way SUB-D Screw ABE7CPA01 0.300
Counter, axis control,
position control
Modicon
Premium
TSXCTYpA
TSXCAYp1
15-way SUB-D Screw ABE7CPA01 0.300
Connection of absolute
encoder with parallel
output
Modicon
Premium
TSXCTYpA
TSXCAYp1
15-way SUB-D Screw ABE7CPA11 0.330
Distribution of 4
thermocouples
Modicon M340BMXART0414
BMXART0814
25-way SUB-D Screw ABE7CPA412 0.180
Distribution of 16
thermocouples
Modicon
Premium
TSXAEY1614 25-way SUB-D Screw ABE7CPA12 0.300
Passive distribution of 8
analog EIS channels
on screw terminals,
with shield continuity
Modicon
Premium
TSXASY810
TSXAEY1600
TSXApY800
25-way SUB-D Screw ABE7CPA02 0.290
Modicon M340 BMXAMI0800
BMXAMI0810
BMXAMO0802
Provision and
distribution of protected
isolated power supplies
for 4 analog input
channels
Modicon M340 BMXAMI0410 25-way SUB-D Screw ABE7CPA410 0.180
Distribution of 4 analog
output channels
Modicon
Premium
TSXASY410
TSXAEY420
25-way SUB-D Screw ABE7CPA21 0.210
Modicon M340 BMXAMO0410
Distribution and supply
of 8 analog input
channels with limitation of
each current loop
Modicon
Premium
TSXAEY800
TSXAEY1600
25-way SUB-D Screw ABE7CPA03 0.330
Distribution and supply
of 8 analog input
channels isolated from
one another with 25 mA/
channel limitation
Modicon
Premium
TSXAEY810 25-way SUB-D Screw ABE7CPA31 0.410
Modicon M340 BMXAMI0800
BMXAMI0810
BMXAMO0802 Spring ABE7CPA31E 0.410
Safety Modicon
Premium
TSXPAY2p2 25-way SUB-D Screw ABE7CPA13 0.290
Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Connection sub-bases for counter and analog channels
References
ABE7CPA 21/410/412
ABE7CPA11
ABE7CPA01
1
2
3
4
5
6
7
8
9
10
5/19
Accessories
Description No. of channels Specications Order in
multiples of
Unit
reference
Weight
kg
Kit for mounting on solid
plate
––10 ABE7ACC01 0.008
Splitter sub-base 16 as 2 x 8 channels 1ABE7ACC02 0.075
Redundant output
sub-base
16 as 2 x 16 channels 1ABE7ACC10 0.075
Redundant input sub-base 16 as 2 x 16 channels 1ABE7ACC11 0.075
Plug-in continuity blocks Width 10 mm 4ABE7ACC20 0.007
Width 12 mm 4ABE7ACC21 0.010
Enclosure feedthrough
with CNOMO M23
connector (1 x 20-way HE
10 connector, PAC end)
16 19-way 1ABE7ACC82 0.150
Impedance adaptor for
compatibility
Type 2
Used with
ABE7ACC82 and
ABE7ACC83
1ABE7ACC85 0.012
IP 65 cable gland For 3 cables 5ABE7ACC84 0.300
Additional snap-on
terminal blocks (shunted
terminals)
8 10 screw terminals 5ABE7BV10 0.030
16 20 screw terminals 5ABE7BV20 0.060
I/O simulator sub-base 16 For display,
forcing inhibition,
continuity
1ABE7TES160 0.350
Self-adhesive marker tag
holder
For 6 characters 50 AR1SB3 0.001
Quick-blow fuses 5 x 20,
250 V, UL
0.125 A 10 ABE7FU012 0.010
0.5 A 10 ABE7FU050 0.010
1 A 10 ABE7FU100 0.010
2 A 10 ABE7FU200 0.010
4 A 10 ABE7FU400 0.010
6.3 A 10 ABE7FU630 0.010
Commoning link accessories
Description For common Color Distance between
cable ends
Reference Weight
kg
Commoning links
Modularity 8 x 1 mm2
Coil White 12 cm ABFC08R12W 0.020
2 cm ABFC08R02W 0.010
aRed 12 cm ABFC08R12R 0.020
2 cm ABFC08R02R 0.010
cBlue 12 cm ABFC08R12B 0.020
2 cm ABFC08R02B 0.010
Modicon M340
automation platform
Connection interfaces
Modicon Telefast ABE7 pre-wired system
Accessories for connection sub-bases
ABE7ACC02
ABE7ACC80 + ABE7ACC81
ABE7BV20
22 0 1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0 1
ABE7TES160
AR1SB3
ABEC08Rppp
References (continued)
1
2
3
4
5
6
7
8
9
10
5/20
Selection guide Modicon M340
automation platform
Phaseo power supplies and transformers
Regulated switch mode power supplies
Power supplies Regulated switch mode power supplies
ABL8MEM, ABL7RM: 7 to 60 W - Rail mounting
ABL8REM, ABL7RP: 60 to 144 W - Rail mounting
ABL4: 85 to 960 W - Compact - Rail mounting Function modules ABL8DCC: converters c/c
Nominal input voltage a 100 to 240 V
c 120 to 250 V
a 100 to 230 V a 120 V or a 230 V a 400 to 500 V c 24 V
Connection to
worldwide line
supplies
United States
120 V (phase-to-neutral)-
240 V (phase-to-phase)-
Single-phase (N-L1) connection
or
2-phase (L1-L2) connection
Single-phase (N-L1)
connection
Single-phase (N-L1)
connection
or
2-phase (L1-L2) connection
– –
Europe
230 V (phase-to-neutral)-
400 V (phase-to-phase)-
Single-phase (N-L1) connection Single-phase (N-L1)
connection
3-phase (L1-L2-L3)
connection
United States
277 V (phase-to-neutral)-
480 V (phase-to-phase)-
3-phase (L1-L2-L3)
connection
Undervoltage control Yes No No No
Protection against overloads and short-circuits Yes, voltage detection.
Automatic reset on elimination of the detected fault
Yes, current limitation
Automatic reset on elimination of the detected fault
Yes, current limitation
Diagnostics relay Yes Yes Yes Yes, depending on model
Compatibility with function modules Yes with buffer module, battery and battery check modules, redundancy module and discriminating downstream protection module
Power reserve (Boost) 1.25 to 1.4 In for 1 minute, depending on model (for ABL8MEM) No Depending on model: 1.5 to 1.7 In for 5 to 30 seconds No
Output voltage c 5 V c 12 V c 24 V c 48 V c 24 V c 5 V c 7 to 12 V
Output current 0.3 A ABL8MEM24003
0.6 A ABL8MEM24006
1.2 A ABL8MEM24012
2 A ABL8MEM12020 ABL8DCC12020 (1)
2.5 A ABL7RM24025 ABL7RP4803
3 A ABL8REM24030
3.5 A ABL4RSM24035
4 A ABL8MEM05040
5 A ABL7RP1205 ABL8REM24050 ABL4RSM24050
6 A ABL8DCC05060 (1)
10 A ABL4RSM24100
20 A ABL4RSM24200 ABL4WSR24200
30 A ABL4WSR24300
40 A ABL4WSR24400
Pages 5/25 5/28 (2)
(1) Converter module c/c, is to be used with a Phaseo power supply.
(2) Certain offers can not be marketed in certain countries, please consult your “Customer Care Center”.
1
2
3
4
5
6
7
8
9
10
5/21
Power supplies Regulated switch mode power supplies
ABL8MEM, ABL7RM: 7 to 60 W - Rail mounting
ABL8REM, ABL7RP: 60 to 144 W - Rail mounting
ABL4: 85 to 960 W - Compact - Rail mounting Function modules ABL8DCC: converters c/c
Nominal input voltage a 100 to 240 V
c 120 to 250 V
a 100 to 230 V a 120 V or a 230 V a 400 to 500 V c 24 V
Connection to
worldwide line
supplies
United States
120 V (phase-to-neutral)-
240 V (phase-to-phase)-
Single-phase (N-L1) connection
or
2-phase (L1-L2) connection
Single-phase (N-L1)
connection
Single-phase (N-L1)
connection
or
2-phase (L1-L2) connection
– –
Europe
230 V (phase-to-neutral)-
400 V (phase-to-phase)-
Single-phase (N-L1) connection Single-phase (N-L1)
connection
3-phase (L1-L2-L3)
connection
United States
277 V (phase-to-neutral)-
480 V (phase-to-phase)-
3-phase (L1-L2-L3)
connection
Undervoltage control Yes No No No
Protection against overloads and short-circuits Yes, voltage detection.
Automatic reset on elimination of the detected fault
Yes, current limitation
Automatic reset on elimination of the detected fault
Yes, current limitation
Diagnostics relay Yes Yes Yes Yes, depending on model
Compatibility with function modules Yes with buffer module, battery and battery check modules, redundancy module and discriminating downstream protection module
Power reserve (Boost) 1.25 to 1.4 In for 1 minute, depending on model (for ABL8MEM) No Depending on model: 1.5 to 1.7 In for 5 to 30 seconds No
Output voltage c 5 V c 12 V c 24 V c 48 V c 24 V c 5 V c 7 to 12 V
Output current 0.3 A ABL8MEM24003
0.6 A ABL8MEM24006
1.2 A ABL8MEM24012
2 A ABL8MEM12020 ABL8DCC12020 (1)
2.5 A ABL7RM24025 ABL7RP4803
3 A ABL8REM24030
3.5 A ABL4RSM24035
4 A ABL8MEM05040
5 A ABL7RP1205 ABL8REM24050 ABL4RSM24050
6 A ABL8DCC05060 (1)
10 A ABL4RSM24100
20 A ABL4RSM24200 ABL4WSR24200
30 A ABL4WSR24300
40 A ABL4WSR24400
Pages 5/25 5/28 (2)
(1) Converter module c/c, is to be used with a Phaseo power supply.
(2) Certain offers can not be marketed in certain countries, please consult your “Customer Care Center”.
1
2
3
4
5
6
7
8
9
10
5/22
Switch mode power supplies: ABL8RP/8WP range
The ABL8RPS/RPM/WPS power supply offer is designed to provide the DC voltage
necessary for the control circuits of automation system equipment. Is comprised of
six products, this range meets the needs encountered in industrial and commercial
applications. These compact electronic switch mode power supplies provide a
quality of output current that is suitable for the loads supplied and compatible with
the Modicon M340, Premium and Quantum automation platforms. When used
with additional function modules, they help ensure continuity of service in the event
of network power outages or inappropriate application performance. Clear
guidelines are given on selecting the function modules and upstream protection
devices that are often used with them, providing a comprehensive solution.
The ABL8RP/8WP range of Phaseo power supplies are to be connected in
phase-to-neutral or phase-to-phase for ABL8RPS/RPM, and in three-phase for
ABL8WPS. They deliver a voltage that is precise to 3%, whatever the load and
whatever the type of line supply, within the ranges:
85 to 132 V va and 170 to 550 V a for ABL8RPS
85 to 132 V va and 170 to 264 V a for ABL8RPM
340 to 550 V va for ABL8WPS
Their very wide input voltage range allows a considerable reduction of parts held in
stock and offers a distinct advantage in terms of machine design.
Conforming to IEC standards and UL and CSA certied, they are suitable for
ABL8RP/8WP use.
ABL8RPS/RPM and ABL8WPS power supplies are equipped with a harmonic
lter, helping to ensure compliance with standard IEC/EN 61000-3-2 concerning
harmonic pollution.
The ABL8RP/8WP range of Phaseo power supplies has protection devices to help
ensure optimum performance of the automation system. Their operating mode can
be congured as required by the user:
Manual reset protection mode:
b Priority is given to the voltage to help maintain
the PAC logic states and nominal operation of the supplied actuators.
Automatic reset protection mode:
b Priority is given to the current to allow
troubleshooting for example, or to help ensure continuity of service until the arrival of
the maintenance team.
The ABL8RP/8WP range of Phaseo power supplies also has a power reserve,
allowing them to deliver a current of 1.5 In at regular intervals. This avoids the need
to oversize the power supply if the device has a high inrush current, while ensuring
optimum performance of the automation system.
The diagnostics for the ABL8RP/8WP range of Phaseo power supplies are available
on the front of the device via LEDs (Uout and Iout) and via a volt-free relay contact
(whether or not the PAC states are veried).
Products are equipped with an output voltage adjustment potentiometer to
compensate for any line voltage drops in installations with long connection cable runs.
These power supplies are designed for direct mounting on a 35 mm DIN rail.
Modicon M340
automation platform
Phaseo power supplies and transformers
Regulated switch mode power supplies
ABL8RP, ABL8WP
Introduction
ABL8RPS24050
c
a
Modicon M340 PAC
1
2
3
4
5
6
7
8
9
10
5/23
Switch mode power supplies: ABL8RP/8WP range (continued)
There are four references available in the ABL8RP/8WP range of Phaseo power
supplies for phase-to-neutral or phase-to-phase connection:
ABL8RPS24030
b 72 W 3 A 24 V c
ABL8RPS24050
b 120 W 5 A 24 V c
ABL8RPS24100
b 240 W 10 A 24 V c
ABL8RPM24200
b 480 W 20 A 24 V c
The ABL8RP/8WP range of Phaseo power supplies also features two references for
three-phase connection:
ABL8WPS24200
b 480 W 20 A 24 V c
ABL8WPS24400
b 960 W 40 A 24 V c
A range of function modules also allows functions to be added to the ABL8RP/8WP
range of Phaseo power supplies to help ensure continuity of service:
Buffer module or Battery control modules combined with their batteries to help v
ensure continuity of service in the event of a network power outage
Redundancy module to meet the demanding requirements for continuity of v
service even if the power supply becomes inoperative
Downstream electronic Protection modules to help ensure that the protection in v
the application is discriminating
Converter modules delivering nominal voltages of 5 and 12 V v c from the 24 V
c output of the ABL8RP/8WP range of Phaseo power supplies
Description
ABL8RP/8WP range of power supplies
The ABL8RP/8WP range of Phaseo regulated switch mode power supplies,
ABL8RPS24pp0/RPM24200/WPS24p00, feature:
1 Spring clip for 35 mm DIN rail
2 4 mm2 enclosed screw terminals for connection of the AC voltage (single-phase,
phase-to-phase or three-phase connection)
3 Protective glass ap
4 Clip-on marker label
5 Locking catch for the glass ap (sealable)
6 Protection mode selector
7 Output voltage adjustment potentiometer
8 Output voltage status LED (green and red)
9 Output current status LED (green, red and orange)
10 Screw terminals for connection of the diagnostic relay contact, except
ABL8RPS24030
11 4 mm2 (10 mm2 on ABL8WPS24p00 and ABL8RPM24200) enclosed screw
terminals for connection of the DC output voltage
Modicon M340
automation platform
Phaseo power supplies and transformers
Regulated switch mode power supplies
ABL8RP, ABL8WP
Introduction (continued),
description
ABL8WPS24200
Modicon Premium
a
c
11
10
9
8
7
6
4
3
2
5
1
1
2
3
4
5
6
7
8
9
10
5/24
Combinations
Selection of protection on the power supply primaries
Type of line supply 115 V a phase-to-neutral 230 V a phase-to-phase 400 V a phase-to-phase
Type of protection Thermal-magnetic
circuit-breaker
gG/gL
fuse
Thermal-magnetic
circuit-breaker
gG/gL
fuse
Thermal-
magnetic
circuit-
breaker
gG/gL
fuse
(1)
GB2 (IEC) (4)
(2)
C60N (IEC/UL)
– (1)
GB2 (IEC) (3)
(2)
C60N (IEC/UL)
– (1)
GV2 (IEC/UL)
ABL8RPS24030 GB2CD07 MG24443 2 A (8 x 32) GB2CD07 MG24443 2 A (8 x 32) GV2RT06
GV2ME06 (4)
2 A (14 x 51)
ABL8RPS24050 GB2CD08 MG24444 4 A (8 x 32) GB2CD07 MG24443 2 A (8 x 32) GV2RT06
GV2ME06 (4)
2 A (14 x 51)
ABL8RPS24100 GB2CD12 MG24447 6 A (8 x 32) GB2CD08 MG24444 4 A (8 x 32) GV2RT07
GV2ME07 (4)
4 A (14 x 51)
ABL8RPM24200 GB2CD16 MG24449 10 A (8 x 32) GB2CD12 MG24447 6 A (8 x 32)
ABL8WPS24200 GV2ME06 (5) 2 A (14 x 51)
ABL8WPS24400 GV2ME07 (5) 4 A (14 x 51)
(1) Automation and Control offer.
(2) Electrical Distribution offer.
(3) UL certication pending.
(4) Connection in single-phase (L-N) or phase-to-phase (L1-L2).
(5) Connection in 3 phase (L1-L2-L3).
Modicon M340
automation platform
Phaseo power supplies and transformers
Regulated switch mode power supplies
ABL8RP, ABL8WP
1
2
3
4
5
6
7
8
9
10
5/25
Regulated switch mode power supplies: Phaseo ABL8RP/8WP range
Input
voltage
Secondary Reset Conforming
to standard
IEC/EN
61000-3-2
Reference Weight
kg
Output
voltage
Nominal
power
Nominal
current
Single-phase (N-L1) or 2-phase (L1-L2) connection
100 to 120 V -
200 to 500 V a
- 15%,+ 10%
50/60 Hz
24 to 28.8 V
c72 W 3 A Auto/man Yes ABL8RPS24030 0.300
120 W 5 A Auto/man Yes ABL8RPS24050 0.700
240 W 10 A Auto/man Yes ABL8RPS24100 1.000
100 to 120 V -
200 to 240 V a
- 15%,+ 10%
50/60 Hz
24 to 28.8 V
c480 W 20 A Auto/man Yes ABL8RPM24200 1.600
Three-phase connection (L1-L2-L3)
380 to 500 V a
± 10 %
50/60 Hz
24 to 28.8 V
c480 W 20 A Auto/man Yes ABL8WPS24200 1.600
960 W 40 A Auto/man Yes ABL8WPS24400 2.700
Function modules for continuity of service (1)
Function Use Designation Reference Weight
kg
Continuity after
a power outage
Holding time 100 ms at 40 A
and 2 s at 1 A
Buffer module ABL8BUF24400 1.200
Holding time 9 min at 40 A to 2 hrs at 1
A (depending on use with a Battery
control module-battery unit and load)
(2)
Battery control module
20 A output current
ABL8BBU24200 0.500
Battery control module
40 A output current
ABL8BBU24200 0.700
3.2 Ah battery module (3) ABL8BPK24A03 3.500
7 Ah battery module (3) ABL8BPK24A03 6.500
12 Ah battery module (3) ABL8BPK24A12 12.000
Continuity after
a detected
malfunction
Paralleling and redundancy of the
power supply to help ensure
uninterrupted operation of the
application excluding AC line failures
and application overloads
Redundancy module ABL8RED24400 0.700
Downstream
protection
Electronic protection (1 to 10 A
overload or short-circuit) with 4 output
terminals from a ABL8RP/8WP range
Phaseo power supply
Protection module with
2-pole breaking (4) (5)
ABL8PRP24100 0.270
c / c converters (1)
Primary (6) Secondary Reference Weight
kg
Input voltage ABL8RP/8WP range power supply
module output current
Output
voltage
Nominal
current
24 V c
- 9%, + 24%
2.2 A 5 to 6.5 V c6 A ABL8DCC05060 0.300
1.7 A 7 to 15 V c 2 A ABL8DCC12020 0.300
Separate and replacement parts
Designation Use Composition Unitreference Weight
kg
Fuse assemblies For ABL8PRP24100 discriminating
Protection modules
4 x 5 A, 4 x 7.5 A
and 4 x 10 A
ABL8FUS01
For ABL8BKP24App Battery 4 x 20 A and 6 x 30 A ABL8FUS02
Clip-on marker
labels
For ABL8s excluding
ABL8PRP24100
Order in multiples of 100 LAD90 0.030
ABL8PRP24100 selective Protection
Module
Order in multiples of 22 ASI20MACC5
DIN rail
mounting kit
ABL8BPK2403 Battery Module ABL1A02
EEPROM
memory
Backup and duplication of ABL8
BBU24p00 battery control module
parameters
SR2MEM02 0.010
(1) For use with ABL8RP/8WP range of Phaseo power supplies.
(2) For table of compatibility of Battery control module-battery unit with holding time depending on the load.
(3) Supplied with 20 or 30 A fuse depending on the model.
(4) Supplied with four 15 A fuses.
(5) Local reset via push button or automatic reset on elimination of the detected fault.
(6) Voltage from a 24 V c ABL8RP/8WP range Phaseo power supply.
Modicon M340
automation platform
Phaseo power supplies and transformers
Regulated switch mode power supplies
ABL8RP, ABL8WP
References
ABL8RPS24050
ABL8RPM24200
ABL8WPS24200
ABL8BUF24400
ABL8BBU24200
ABL8RED24400
1
2
3
4
5
6
7
8
9
10
5/26
Introduction Modicon M340
automation platform
Phaseo power supplies and transformers
Regulated switch mode power supplies
ABL4
Introduction
The range
The Phaseo regulated switch mode power supplies ABL4 offer is designed to
provide the DC voltage necessary for the control circuits of automation system
equipment consuming 85 W to 960 W on c 24 V.
This range of power supplies, comprised of 7 products, meets the needs
encountered in industrial applications.
Using electronic switch mode technology, these power supplies provide a quality of
output current that is suitable for the loads supplied and compatible with the following
products:
Twido b programmable controllers
Modicon b logic controllers M238 and M258
Modicon motion controllers LMC 058 b
Automation platforms M340 b, Premium and Quantum
Due to their high overload withstand, the power supplies ABL4 are the power supply
solution for stepper motors, servo motors and integrated drives.
When used with function modules ABL8B/RED/D/P, they help ensure continuity of
service in the event of power outages or detected application malfunction. In
addition, the ABL4RSM24200 model can be used in a redundant power supply
without an additional redundancy module due to its integrated diode.
Their high effectiveness enables us to offer power supplies that are among the
smallest on the market, thus considerably reducing the space required in
enclosures.
Compatibility with distribution systems
Power supplies ABL4 are connected in phase-to-neutral, phase-to-phase (1) for the
ABL4R, and in 3-phase for the ABL4W.
They deliver a voltage that is precise to within ± 1% whatever the load and whatever
the type of line supply, within the following ranges:
a b 90 to 264 V for the ABL4RSM24035 and ABL4RSM24050,
a b 90 to 132 V and a 185 to 264 V for the ABL4RSM24100 and ABL4RSM24200,
a b 340 to 550 V for the ABL4W.
Standards and certications
Conforming to IEC standards and UL certied, the power supplies ABL4 are suitable
for universal use. They can be used to supply Protection Extra Low Voltage (PELV)
or Safety Extra Low Voltage (SELV) circuits in compliance with standard IEC/EN
60364-4-41. Due to their double insulation between the input circuit (connected to
the line supply) and the output circuit and their internal device,voltage is limited to
less than 60 V in the event of a detected internal fault.
Diagnostics
The operation of the power supply ABL4 can be checked using 2 LEDs located on
the front face.
A normally open contact (NO) relay also enables checking of the output voltage
compliance (contact closed if the output voltage exceeds 90% of the nominal
voltage).
Protection
Power supplies ABL4 have the following continuous protection (2):
protection against overvoltages on the output circuit, b
thermal protection, b
protection against overcurrents and short-circuits on the output circuit. b
Mounting
Power supplies ABL4 are mounted on Omega (DIN 35 mm) rail.
(1) Only on certain American line supplies.
(2) With automatic restarting.
1
2
3
4
5
6
7
8
9
10
5/27
Specications
Derating
The ambient temperature is a determining factor that limits the power that an electronic power supply can
deliver continuously. If the temperature around the electronic components is too high, their life will be
signicantly reduced.
The nominal ambient temperature for power supplies ABL4 is, depending on the reference, 45, 50 or 60°C.
Above this temperature, derating is necessary up to a maximum temperature of 60°C.
The adjacent graph shows the
power as a percentage of the
nominal power that the power
supply can deliver
continuously, in relation to the
ambient temperature.
Temperature °C
P/Pn %
0
20
40
60
80
100
120
75
50
70
-20 20 30 45 50 55 600
ABL4RSM24035/RSM24050/WSR24400
ABL4WSR24200
ABL4WSR24300
ABL4RSM24100
Adequate convection is required around the products to assist cooling.
Sufcient clearance is required around power supplies ABL4: refer to instruction sheet supplied with each power
supply, also available at www.schneider-electric.com
Temporary overcurrents
Power supplies ABL4 have an energy reserve allowing them to supply the application, according to the
references, from 150% to 170% of the nominal current for 5 seconds and up to 30 seconds, while guaranteeing an
output voltage higher then 90% of the nominal voltage.
Power supply Maximum temporary overcurrent Maximum time of temporary overcurrent
ABL4RSM24035 170% of nominal current 30 seconds
ABL4RSM24050 160% of nominal current 30 seconds
ABL4RSM24100 150% of nominal current 30 seconds
ABL4RSM24200
ABL4WSR24p00
150% of nominal current 5 seconds
The time interval between each overcurrent cannot be less than 10 seconds.
When the overcurrent value exceeds the reserve energy value or when the overcurrents are too closely spaced or
when the overcurrent is prolonged (depending on the reference), more than 5 seconds and up to 30 seconds, the
power supply switches to protection mode.
Behavior in event of overcurrents and short-circuits
In the event of overcurrent or short-circuit, the power supply ABL4 switches to protection mode and periodically
attempts a reset (“Hiccup” mode) until the detected fault disappears. Once the output circuit load conditions return
to normal, the power supply automatically resets.
Power supply Periodic reset frequency type
ABL4RSM24035
ABL4RSM24050
ABL4RSM24100
Variable: depends on the overcurrent value and the ambient temperature.
In the event of a short-circuit (output voltage close to 0 V), the current is established for 50 ms
approximately every 1.8 seconds.
ABL4RSM24200
ABL4WSR24p00
Mounted: the current is established for 5 seconds every 15 seconds either in the event of an
overcurrent or a short-circuit.
Connecting in parallel
To increase the current available, the outputs of two power supplies with identical references can be
connected in parallel.
Equitable sharing of the current between the two power supplies is accomplished performing the following tasks:
Use two power supplies bearing the same date code and same reference. b
Adjust the output voltages to obtain the same voltage value, to within plus or minus 20 mV, 10 minutes after b
power-up with a load consumption of less than 20% connected on each power supply output.
Connect one of the “+” terminals and one of the “-” terminals of each power supply to a terminal using wires of b
the same length and diameter.
Use wires with the largest cross-section as possible. b
The maximum usable current is 1.8 times the nominal current of the power supply.
Redundancy of the power supply ABL4RSM24200 can be achieved without adding a specic module, due to the
specic diode that is integrated in these products.
For other power supply references, use redundancy module ABL8RED24400.
Additional technical information is available at www.schneider-electric.com.
Specications Modicon M340
automation platform
Phaseo power supplies and transformers
Regulated switch mode power supplies
ABL4
1
2
3
4
5
6
7
8
9
10
5/28
Specications (continued),
description
Modicon M340
automation platform
Phaseo power supplies and transformers
Regulated switch mode power supplies
ABL4
Specications (continued)
Selection of protection on the power supply primaries
Power supply Type of protection
Miniature circuit-
breakers C60N
(Icn > 1.5 kA)
Fuses Class CC fuses with
rejection system
Zone where equipment is used
Rest of the world USA & Canada
ABL4RSM24035 4 A curve C 4 A time-lag 6 A
ABL4RSM24050 4 A curve C 4 A time-lag 6 A
ABL4RSM24100 6 A curve C 6.3 A time-lag 6 A
ABL4RSM24200 16 A curve C
10 A curve D
15 A time-lag 10 A
ABL4WSR24200 3 x 10 A curve C 3 x 3.15 A time-lag 3 x 10 A
ABL4WSR24300 3 x 10 A curve C 3 x 5 A time-lag 3 x 10 A
ABL4WSR24400 3 x 10 A curve C 3 x 6.3 A time-lag 3 x 10 A
Description
The regulated switch mode power supplies ABL4RSM24035 and
ABL4RSM24050 feature:
Spring clip for Omega (35 mm DIN) rail.1
Output voltage status LED (green).2
Output circuit overcurrent LED (red).3
Output voltage adjustment potentiometer.4
Removable screw terminal block for connection of the DC output voltage and 5
diagnostics contact.
Removable screw terminal block for connection of the AC input voltage on 6
single-phase (1).
The regulated switch mode power supplies ABL4RSM24100 feature:
Spring clip for Omega (35 mm DIN) rail.1
Removable screw terminal block for connection of the AC input voltage (on 2
single-phase) (1)) and for connection of 120/230 V selection link.
Output voltage status LED (green).3
Output circuit overcurrent LED (red).4
Output voltage adjustment potentiometer.5
Removable screw terminal block for connection of the DC output voltage and 6
diagnostics contact.
The regulated switch mode power supplies ABL4RSM24200, ABL4WSR24200,
ABL4WSR24300 and ABL4WSR24400 feature:
Spring clip for Omega (35 mm DIN) rail.1
Enclosed screw terminals for connection of the DC output voltage and 2
diagnostics contact.
Output voltage adjustment potentiometer.3
Output voltage status LED (green).4
Output circuit overcurrent and detected alarm LED (red).5
Enclosed screw terminals for connection of the AC input voltage:6
single-phase connection for ABL4RSM24200 - (1),
3-phase connection for ABL4W - pppp.
(1) Connection between 2 phases only on certain American line supplies.
2
4
5
6
3
1
4
1
2
5
6
3
2
1
3
4
5
6
1
2
3
4
5
6
7
8
9
10
5/29
References Modicon M340
automation platform
Phaseo power supplies and transformers
Regulated switch mode power supplies
ABL4
Phaseo regulated switch mode power supplies ABL4, 85 to 960 W
Input voltage Secondary Reset Reference Weight
kg
Output
voltage
Nominal
power
Nominal
current
Single-phase (N-L1) connection (1)
a 100 to 230 V
- 10%, + 15%
c 23 to 27.4 V 85 W 3.5 A Automatic ABL4RSM24035 0.500
120 W 5 A Automatic ABL4RSM24050 0.500
a 120 V
- 25%, + 10%
and
a 230 V
- 20%, + 15%
c 23 to 27.4 V 240 W 10 A Automatic ABL4RSM24100 0.800
c 24 to 27.8 V 480 W 20 A Automatic ABL4RSM24200
(2)
1.300
3-phase (L1-L2-L3) connection
a 400 to 500 V
- 15%, + 10%
c 24 to 27.8 V 480 W 20 A Automatic ABL4WSR24200 1.300
720 W 30 A Automatic ABL4WSR24300 1.300
960 W 40 A Automatic ABL4WSR24400 1.300
Function modules for continuity of service (3)
Function Use Description Reference Weight
kg
Continuity after
a power outage
(5)
Holding time 100 ms
at 40 A and 2 s at 1 A
Buffer module ABL8BUF24400 1.200
Holding time 9 min at 40 A to 2 hrs at 1 A
(depending on use with a battery check
module-battery unit and load) (4)
Battery check module,
output current 20 A
ABL8BBU24200 0.500
Battery check module,
output current 40 A
ABL8BBU24400 0.700
Battery module, 3.2 Ah (6) ABL8BPK24A03 3.500
Battery module, 7 Ah (6) ABL8BPK24A07 6.500
Battery module, 12 Ah (6) ABL8BPK24A12 12.000
Continuity after
a detected
malfunction
Paralleling and redundancy of the power supply
to help ensure uninterrupted operation of the
application excluding AC line failures and
application overcurrents
Redundancy module ABL8RED24400 0.700
Downstream
protection
Electronic protection (1 to 10 A overcurrent or
short-circuit) of 4 output terminals from an ABL4
power supply
Protection module with 2-pole
breaking (7) (8)
ABL8PRP24100 0.270
Converters c / c (3)
Primary (9) Secondary Reference Weight
kg
Input voltage Power supply module output current Output
voltage
Nominal
current
c 24 V
- 9%,+ 24%
2.2 A c 5 to 6.5 V 6 A ABL8DCC05060 0.300
1.7 A c 7 to 15 V 2 A ABL8DCC12020 0.300
Separate and replacement parts
Description Use Composition Unitreference Weight
kg
Fuse
assemblies
Discriminating Protection module
ABL8PRP24100
4 x 5 A, 4 x 7.5 A and 4 x 10 A ABL8FUS01
Battery ABL8BKP24App 4 x 20 A and 6 x 30 A ABL8FUS02
Clip-on marker
labels
For ABL8s excluding ABL8PRP24100 Sold in lots of 100 LAD90 0.030
Discriminating Protection module
ABL8PRP24100
Sold in lots of 22 ASI20MACC5
Rail mounting
kit
Battery module ABL8BPK2403 ABL1A02
EEPROM
memory
Backup and duplication of ABL8 BBU24p00
battery check module parameters
SR2MEM02 0.010
(1) 2-phase connection possible on certain American line supplies.
(2) Power supply reference ABL4RSM24200 has an integrated redundancy diode.
(3) For use with power supply ABL4.
(4) Compatibility table for battery check module-battery unit with holding time depending on the load.
More technical information is available at www.schneider-electric.com.
(5) Technical appendices are available at www.schneider-electric.com.
(6) Supplied with 20 or 30 A fuse depending on the model.
(7) Supplied with four 15 A fuses.
(8) Local reset via push button or automatic reset on elimination of the detected fault.
(9) Voltage from power supply ABL4.
ABL4RSM24050
ABL4RSM24100
ABL4WSR24200
ABL8BUF24400
ABL8BBU24200
ABL8RED24400
1
2
3
4
5
6
7
8
9
10
5/30
Modicon M340
automation platform
Operator dialog terminals
Magelis Small Panels
Selection guide
Applications Display of graphic pages
Control and conguration of data
Type of terminal Small Panels with touch
screen
Display Type
Monochrome LCD STN
(200 x 80 pixels),
backlit
Green, orange and red or-
White, pink and red-
Color QVGA TFT LCD
(320 x 240 pixels)
Capacity
3.4” (monochrome) 3.5” (color) 5.7” (color)
Data entry Via touch screen
Memory
capacity
Application 16 MB Flash
Extension –
Functions Maximum number of pages Limited by internal FLASH EPROM memory capacity
Variables per page Unlimited
ReIntroduction of variables Alphanumeric, bitmap, bar chart, gauge, curves, buttons, LEDs
Recipes 32 groups of 64 recipes
Curves Yes, with log
Alarm logs Yes
Real-time clock Access to the PAC real-time clock
Alarm relay
Buzzer Yes
Communication Asynchronous serial link RS 232C/RS 485
Downloadable protocols Uni-TE, Modbusand for PAC brands:
Allen-Bradley, Omron, Mitsubishi, Siemens
Printer link USB for serial or parallel printer
USB ports 1 host type A and 1 device type mini B
Networks 1 Ethernet TCP/IP port
(10BASE-T/100BASE-TX)
Development software Vijeo Designer (on Windows XP, Windows Vista and Windows 7)
Operating systems Magelis
Type of terminal Magelis STO Magelis STU
Pages Please consult the “Human/Machine Interfaces” catalog.
1
2
3
4
5
6
7
8
9
10
5/31
Display of text messages and/or semi-graphic
pages
Display of text messages and/or semi-graphic pages
Control and conguration of data
Small Panels with keypad Small Panels with keypad Small Panels with touch screen and keypad
Green backlit monochrome LCD,
height 5.5 mm
or
Green, orange and red backlit monochrome LCD,
height 4.34 to 17.36 mm
Green, orange and red backlit monochrome LCD,
height 4.34 to 17.36 mm
Green, orange and red backlit monochrome matrix
LCD (198 x 80 pixels),
height 4 to 16 mm
2 lines of 20 characters or
1 to 4 lines of 5 to 20 characters
(monochrome)
1 to 4 lines of 5 to 20 characters (monochrome) 2 to 10 lines of 5 to 33 characters (monochrome)
Via keypad with
8 keys (4 customizable)
Via keypad with
12 function keys or numeric entry (depending on
b
context)
8 service keys
b
Via keypad with
4 function keys
b
8 service keys
b
Via touch screen and
keypad with
10 function keys
b
2 service keys
b
512 KB Flash 512 KB Flash EPROM
128/200 application pages
256 alarm pages
128/200 application pages
256 alarm pages
200 application pages
256 alarm pages
40 to 50 50
Alphanumeric Alphanumeric, bar chart, buttons, LEDs
Yes
Yes (2) Yes
Access to the PAC real-time clock Access to the PAC real-time clock
Yes (1)
RS 232C/RS 485
Uni-TE, Modbus and for PAC brands:
Allen-Bradley, Omron, Mitsubishi, Siemens
RS 232C serial link (2)
Vijeo Designer Lite (on Windows 2000, Windows XP or Windows Vista)
Magelis
XBTN XBTR XBTRT
Please consult the “Human/Machine Interfaces” catalog.
(1) Only XBTRT511.
(2) Depending on model.
1
2
3
4
5
6
7
8
9
10
5/32
Modicon M340
automation platform
Operator dialog terminals
Magelis GT, GK, GH and GTW Advanced Panels
Applications Display of text messages, graphic objects and synoptic views
Control and conguration of data
Type of terminal Touch screen Advanced Panels
Display Type Backlit monochrome (amber or
red mode) STN LCD
(320 x 240 pixels) or TFT LCD
Backlit monochrome or color
STN LCD or backlit color TFT
LCD (320 x 240 pixels or 640 x
480 pixels) (3)
Backlit color STN LCD or
TFT LCD (640 x 480 pixels)
Capacity 3.8” (monochrome or color) 5.7” (monochrome or color) 7.5” (color)
Data entry Via touch screen
Static function keys
Dynamic function keys
Service keys
Alphanumeric keys
Memory capacity Application 32 MB Flash EPROM 16 MB Flash EPROM (3) 32 MB Flash EPROM
Expansion By means of 128, 256, 512 MB, 1, 2 or 4 GB CF card (except
XBTGT2110)
Functions Maximum number of pages Limited by internal Flash
EPROM memory capacity
Limited by capacity of internal Flash EPROM memory or CF
card memory
Variables per page Unlimited (8000 variables max.)
ReIntroduction of variables Alphanumeric, bitmap, bargraph, gauge, tank, tank level indicator, curves, polygon, button,
LED
Recipes 32 groups of 64 recipes is comprised of 1024 ingredients max.
Curves Yes, with log
Alarm logs Yes
Real-time clock Built-in
Discrete I/O 1 input (reset) and 3 outputs
(alarm, buzzer, run)
Multimedia I/O (3) 1 audio input (microphone),
1 composite video input
(digital or analog video
camera), 1 audio output
(loudspeaker) (1)
Communication Downloadable protocols Uni-TE (2), Modbus, Modbus TCP/IP (1) and for PAC brands: Mitsubishi, Omron,
Allen-Bradley and Siemens
Asynchronous serial link RS 232C/485 (COM1) RS 232C/RS 422/485 (COM1) and RS 485 (COM2)
USB ports 1 1 (3) 2
Buses and networks Modbus Plus and FIPway with USB gateway, Probus DP
and DeviceNet with optional card
Ethernet TCP/IP (10BASE-T/100BASE-TX) (1)
Printer link USB port for parallel printer RS 232C (COM1) serial link, USB port for parallel printer
Development software Vijeo Designer (36349/11) (on Windows XP, Windows Vista and Windows 7)
Operating system Magelis
(200 MHz RISC CPU)
Magelis
(133 MHz RISC CPU) (3)
Magelis
(266 MHz RISC CPU)
Type of terminal XBTGT11/13 XBTGT21/22/23/24/29 XBTGT42/43
Pages Please consult the “Human/Machine Interfaces” catalog.
(1) Depending on model.
(2) Uni-TE version V2 for Twido controller and TSX Micro/Premium platform.
(3) For XBTGT 2430, 32 MB Flash EPROM, 1 sound output, 2 USB ports, 266 MHz RISC CPU
(4) For XBTGT 5430
Selection guide
1
2
3
4
5
6
7
8
9
10
5/33
Display of text messages, graphic objects and synoptic views
Control and conguration of data
Touch screen Advanced Panels
Backlit color STN LCD or TFT LCD (640 x 480 pixels
or 800 x 600 pixels) (4)
Backlit color TFT LCD (800 x 600 pixels) Backlit color TFT LCD (1024 x 768 pixels)
10.4” (color) 12.1” (color) 15” (color)
Via touch screen
32 MB Flash EPROM
By means of 128, 256, 512 MB, 1, 2 or 4 GB CF card
Limited by capacity of internal Flash EPROM memory or CF card memory
Unlimited (8000 variables max.)
Alphanumeric, bitmap, bargraph, gauge, tank, tank level indicator, curves, polygon, button, LED
32 groups of 64 recipes is comprised of 1024 ingredients max.
Yes, with log
Yes
Built-in
1 input (reset) and 3 outputs (alarm, buzzer, run)
1 audio input (microphone), 1 composite video input (digital or analog video camera), 1 audio output (loudspeaker) (1)
Uni-TE (2), Modbus, Modbus TCP/IP (1) and for PAC brands: Mitsubishi, Omron, Allen-Bradley and Siemens
RS 232C/RS 422/485 (COM1) and RS 485 (COM2)
2
Modbus Plus with USB gateway
Ethernet TCP/IP (10BASE-T/100BASE-TX)
RS 232C (COM1) serial link, USB port for parallel printer
Vijeo Designer (36349/11) (on Windows XP, Windows Vista and Windows 7)
Magelis
(266 MHz RISC CPU)
XBTGT52/53/54 XBTGT63 XBTGT73
Please consult the “Human/Machine Interfaces” catalog.
1
2
3
4
5
6
7
8
9
10
5/34
Applications Display of text messages, graphic objects and synoptic views
Control and conguration of data
Type of terminal Advanced Panels with keypad
Display Type Color TFT LCD
(320 x 240 pixels) or monochrome STN
Color TFT LCD
(640 x 480 pixels)
Capacity 5.7” (monochrome or color) 10.4” (color)
Data entry Via keypad and/or touch screen (congurable) and/or by industrial pointer
Static function keys 10 12
Dynamic function keys 14 18
Service keys 8
Alphanumeric keys 12
Memory capacity Application 16 MB Flash EPROM 32 MB Flash EPROM
Expansion By means of 128, 256, 512 MB, 1, 2 or 4 GB CF card
Functions Maximum number of pages Limited by capacity of internal Flash EPROM memory or CF card memory
Variables per page Unlimited (8000 variables max.)
ReIntroduction of variables Alphanumeric, bitmap, bargraph, gauge, tank, tank level indicator, curves, polygon, button,
LED
Recipes 32 groups of 64 recipes is comprised of 1024 ingredients max.
Curves Yes, with log
Alarm logs Yes
Real-time clock Built-in
Discrete I/O 1 input - 3 outputs
Multimedia I/O
Communication Downloadable protocols Uni-TE (2), Modbus, Modbus TCP/IP (1) and for PAC brands: Mitsubishi, Omron, Allen-
Bradley and Siemens
Asynchronous serial link RS 232C/RS 422/485 (COM1)
RS 485 (COM2)
USB ports 1 2
Buses and networks Modbus Plus, FIPway with USB gateway, Probus DP and DeviceNet with optional card
Ethernet TCP/IP (10BASE-T/100BASE-TX)
Printer link RS 232C (COM1) serial link, USB port for parallel printer
Development software Vijeo Designer (36349/11) (on Windows XP, Windows Vista and Windows 7)
Operating system Magelis
(266 MHz RISC CPU)
Type of terminal XBTGK 21/23 XBTGK 53
Pages Please consult the “Human/Machine Interfaces” catalog.
(1) Depending on model.
(2) Uni-TE version V2 for Twido controller and TSX Micro/Premium platform.
Selection guide (continued) Modicon M340
automation platform
Operator dialog terminals
Magelis GT, GK, GH and GTW Advanced Panels
1
2
3
4
5
6
7
8
9
10
5/35
Applications Display of text messages, graphic objects and synoptic views
Control and conguration of data
Type of terminal Advanced Panels with keypad
Display Type Color TFT LCD
(320 x 240 pixels) or monochrome STN
Color TFT LCD
(640 x 480 pixels)
Capacity 5.7” (monochrome or color) 10.4” (color)
Data entry Via keypad and/or touch screen (congurable) and/or by industrial pointer
Static function keys 10 12
Dynamic function keys 14 18
Service keys 8
Alphanumeric keys 12
Memory capacity Application 16 MB Flash EPROM 32 MB Flash EPROM
Expansion By means of 128, 256, 512 MB, 1, 2 or 4 GB CF card
Functions Maximum number of pages Limited by capacity of internal Flash EPROM memory or CF card memory
Variables per page Unlimited (8000 variables max.)
ReIntroduction of variables Alphanumeric, bitmap, bargraph, gauge, tank, tank level indicator, curves, polygon, button,
LED
Recipes 32 groups of 64 recipes is comprised of 1024 ingredients max.
Curves Yes, with log
Alarm logs Yes
Real-time clock Built-in
Discrete I/O 1 input - 3 outputs
Multimedia I/O
Communication Downloadable protocols Uni-TE (2), Modbus, Modbus TCP/IP (1) and for PAC brands: Mitsubishi, Omron, Allen-
Bradley and Siemens
Asynchronous serial link RS 232C/RS 422/485 (COM1)
RS 485 (COM2)
USB ports 1 2
Buses and networks Modbus Plus, FIPway with USB gateway, Probus DP and DeviceNet with optional card
Ethernet TCP/IP (10BASE-T/100BASE-TX)
Printer link RS 232C (COM1) serial link, USB port for parallel printer
Development software Vijeo Designer (36349/11) (on Windows XP, Windows Vista and Windows 7)
Operating system Magelis
(266 MHz RISC CPU)
Type of terminal XBTGK 21/23 XBTGK 53
Pages Please consult the “Human/Machine Interfaces” catalog.
(1) Depending on model.
(2) Uni-TE version V2 for Twido controller and TSX Micro/Premium platform.
Display of text messages, graphic objects and synoptic views
Control and conguration of data
Portable Advanced Panels Open touch screen Advanced Panels
Color TFT LCD
(640 x 480 pixels)
Color TFT LCD
(800 x 600 pixels)
Color TFT LCD
(800 x 600 pixels)
Color TFT LCD
(1024 x 768 pixels)
5.7” (color) 8.4” (color) 12” (color) 15” (color)
Via touch screen Via touch screen
11
– –
– –
– –
32 MB Flash EPROM 1 GB CF system card included with
terminal, expandable to 4 GB
2 GB CF system card included with terminal,
expandable to 4 GB
By means of 128, 256, 512 MB, 1, 2 or 4 GB CF card
Limited by capacity of internal Flash EPROM memory or CF card memory
Unlimited (8000 variables max.)
Alphanumeric, bitmap, bargraph, gauge, tank, tank level indicator, curves, polygon, button, LED
32 groups of 64 recipes is comprised of 1024 ingredients max.
Yes, with log
Yes
Built-in
1 audio output
Uni-TE (2), Modbus, Modbus TCP/IP
and for PAC brands: Mitsubishi,
Omron, Rockwell Automation and
Siemens
Uni-TE (2), Modbus, Modbus TCP/IP (1) and for PAC brands: Mitsubishi, Omron, Allen-Bradley and Siemens
RS 232C/RS 422-485 (COM1) RS 232C (COM1)
RS 232C (COM2)
RS 232C (COM1) RS 232C (COM1)
RS 232C (COM2 )
1 4 4 + 1 front-mounted
Modbus Plus with USB gateway
1 Ethernet port (10BASE-T/100BASE-TX) 1 TCP/IP Ethernet port (10BASE-T/100BASE-TX) and 1 Ethernet port (10BASE-T/100BASE-TX/1 GB)
RS 232C (COM1 or COM2) serial link, USB port for parallel printer
Vijeo Designer (36349/11) (on Windows XP, Windows Vista and Windows 7)
Magelis
(266 MHz RISC CPU)
Windows XP Embedded
XBTGH 2460 XBTGTW 450 XBTGTW 652 HMIGTW 7353
Please consult the “Human/Machine Interfaces” catalog.
(1) Depending on model.
(2) Uni-TE version V2 for Twido controller and TSX Micro/Premium platform.
1
2
3
4
5
6
7
8
9
10
5/36
Modicon M340
automation platform
HMI software
Selection guide
Applications Traditional architecture, HMI executed on dedicated terminal or PC platform
Conguration software for operator dialog applications
Target products Type Magelis XBTN (1)
Magelis XBTR/RT (1)
Operating system on terminals Proprietary Magelis
Functions Reading/writing of PAC variables Yes
Display of variables Yes
Data processing
Sharing of variables between HMI
applications
Saving of variables to external
database
Development of
graphic
applications
Native library of graphic objects Yes
Container Active X
Java Beans
Curves and detected
alarms
Yes (2)
Scripts –
Online modication of applications
Communication between PACs and HMI application Via I/O drivers
Uploading of applications Yes
Simulation of HMI applications Yes
Redundancy
Recipe management
Report printing
Access security Linked to user prole
Software compatible with OS Windows 2000, Windows XP or Windows Vista
Software type Vijeo Designer Lite
Pages Please consult the “Human/Machine Interfaces” catalog.
(1) Magelis XBT terminals behave transparently on restoration of power.
(2) Depending on model.
1
2
3
4
5
6
7
8
9
10
5/37
Traditional architecture, HMI executed on dedicated terminal or PC platform
Conguration software for operator dialog applications
Magelis STO & Magelis STU
Magelis XBTGT (1), Magelis XBTGK (1)
Magelis XBTGH (1), Magelis GTW (1)
Proprietary for Magelis STO/STU, Magelis XBTGT/GK/GH
Windows XP embedded for Magelis GTW
Yes
Yes
Yes, using expression editor or Java programming
Yes
Yes
Yes, with log
Java
Via I/O drivers
Yes
Yes
Yes
Real-time detected alarms, log data
Linked to user prole
Windows XP, Windows Vista or Windows 7
Vijeo Designer
Please consult the “Human/Machine Interfaces” catalog.
1
2
3
4
5
6
7
8
9
10
5/38
1
2
3
4
5
6
7
8
9
10
6/1
6.1 - Treatment for severe environments
Introduction
b ....................................................6/2
Harsh chemical environments
b ......................................6/2
Extreme climatic environments
b .....................................6/2
6.2 - ‘Ruggedized’ processor modules
References
b ....................................................6/3
6.3 - ‘Ruggedized’ power supply modules
References
b ....................................................6/4
6.4 - ‘Ruggedized racks and rack expansion module
References
b ....................................................6/5
6.5 - ‘Ruggedized’ discrete I/O modules
References
b ....................................................6/6
6.6 - ‘Ruggedized’ analog I/O modules
References
b ....................................................6/7
6.7 - ‘Ruggedized’’ communication modules and
network gateway
References
b ....................................................6/8
6.8 - ‘Ruggedized’ counter modules
References
b ....................................................6/9
‘Ruggedized’ Modicon M340
modules
Contents chapter 6
1
2
3
4
5
6
7
8
9
10
6/2
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Communication:
page 3/2 Software:
page 4/2
Introduction
Protective treatment of Modicon M340 PACs
Modicon M340 PACs comply with TCtreatment requirements (Treatment for
Climates). They are designed as standard to operate in temperatures of 0 to + 60°C.
For installations in industrial production workshops or environments corresponding
to TH(Treatment for Hot and humid environments), PACs are housed in
enclosures providing at least IP 54 protection as specied by standard
IEC/EN 60529, or an equivalent level of protection according to NEMA 250.
Modicon M340 PACs offer IP 20 degree of protection (1). They can be installed
without an enclosure in reserved access areas up to and including pollution level 2
(control room with no dust-producing machinery or activity). Pollution level 2 does not
take account of harsher environments, such as those where the air is polluted with
dust, fumes, corrosive or radioactive particles, vapors or salts, molds, and insects.
Treatment for more severe environments
If the Modicon M340 automation platform has to be used in more severe
environments or is required to start and operate in an extended temperature range,
from - 25°C to + 70°C, the “ruggedizedoffer features industrially hardened
processor and power supply modules, Bus X I/O modules and racks that have
protective coating on their circuit boards.
Note: Capable of starting within an extended temperature range (from - 25°C to + 70°C), a
single-rack conguration is also able to operate at extremely low temperatures (to - 40°C) if
placed in an appropriate enclosure. Please consult our Customer Care Center.
This treatment increases the isolation capability of the circuit boards and their
resistance to:
Condensation
b
Dusty atmospheres (conducting foreign particles)
b
Chemical corrosion, in particular during use in sulphurous atmospheres (oil
b
renery, purication plant, etc.) or atmospheres containing halogens (chlorine, etc.)
This protection, combined with appropriate installation and maintenance, enables
Modicon M340 products to be used in the following environments:
Harsh chemical environments:
b
IEC/EN 60721-3-3 class 3C3: v
14 days; 25°C/relative humidity 75% -
Concentrations (mm - 3/m3): H2S: 2100/SO2: 1850/Cl2: 100
ISA S71.04 classes G1 to G3: v
14 days; 25°C/relative humidity 75% -
Concentrations (mm - 3/m3): H2S: 50/SO2: 300/Cl2: 10/NO2: 1250
IEC/EN 60068-2-52 salt mist, Kb test severity level 2: v
3 x 24-hour cycles -
5% NaCI -
40°C/relative humidity 93% -
Extreme climatic environments:
b
Temperatures from - 25 to + 70°C v
Relative humidity levels up to 93% (95% depending on the device), from + 25 to v
+ 70°C during operation
Formation of ice v
Altitudes from 0 to 5000 m v
Three modules are specically designed for extended temperature ranges from - 25
to + 70°C (the product references include the sufx “T”) :
125 V
b c power supply module BMXCPS3540T (see page 1/9)
125 V
b c discrete input module, 16 channels, BMXDDI1604T (see page 2/12)
125 V
b c discrete relay output module, 8 channels, BMXDRA 0804T (see page 2/12)
(1) Each slot in a BMXXSP ppp0 rack is equipped as standard with a protective cover that
should only be removed when inserting a module. If any covers are subsequently misplaced,
replacements can be ordered under reference BMXXEM010 (sold in lots of 5).
Modicon M340
automation platform
Treatment for severe environments
‘‘Ruggedized’ modules
Introduction
1
2
3
4
5
6
7
8
9
10
6/3
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Communication:
page 3/2 Software:
page 4/2
Introduction (continued)
References and Specications
To order ruggedized modules and racks, see pages 6/3 to 6/9 (the references of the ruggedized products
available include the sufx “H”).
Standard separate parts (cordsets, cables, memory cards, sub-bases, etc.) that are compatible with the
ruggedized modules offer are listed in the reference pages (see pages 6/3 to 6/9).
The majority of operating and electrical specications of ruggedized modules are identical to those of their
equivalent standard versions. However, some specications are subject to either derating or limitation. Please
consult our website www.schneider-electric.com.
BMXP34Modicon M340 “ruggedized” processors (1)
Modicon M340 processor modules are supplied with the BMXRMS008MP Flash memory card. This card
performs the following actions transparently:
Backup of the application (program, symbols and constants) supported in the processor's internal RAM that
b
is not backed up
Activation of the Transparent Ready
b class B10 standard Web server with BMXP341000H Standard
processors and BMXP342020H/20302H Performance processors.
This card can be replaced by either of the BMXRMS008 or BMXRMS128MPF cards that feature a le storage
option.
Max. capacity Memory
capacity
Max. no. of network
modules
Integrated
communication ports
Reference Weight
kg
2 racks
512 discrete I/O
128 analog I/O 20
application-specic
channels
2048 KB
integrated
2 Ethernet networks Modbus serial link BMXP341000H 0.200
4 racks
1024 discrete I/O
256 analog I/O 36
application-specic
channels
4096 KB
integrated
2 Ethernet networks
Modbus serial link
Ethernet network
BMXP342020H 0.205
Ethernet network
CANopen bus
BMXP3420302H 0.215
Standard memory cards
Description Processor compatibility Capacity Reference Weight
kg
Flash memory cards (2) BMXP342020H
BMXP3420302H
8 MB/8 MB les BMXRMS008MPF 0.002
8 MB/128 MB les BMXRMS128MPF 0.002
Standard separate parts
Description Use Length Reference Weight
kg
From To
Terminal port/USB
cordsets
Mini B USB port
on the Modicon
M340 processor
Type A USB port on:
- PC terminal
- Magelis XBTGT/
GK/GTW, GTW HMI,
STU/STO
HMIGraphic terminal
1.8 m BMXXCAUSBH018 0.065
4.5 m BMXXCAUSBH045 0.110
Standard replacement part
Description Use Processor
compatibility
Reference Weight
kg
8 MB Flash memory card Supplied as standard with each
processor. Used for:
Backing up the program, constants, -
symbols and data
Activation of class B10 Web server-
BMXP342020H
BMXP3420302H
BMXRMS008MP 0.002
(1) General specications are the same as those of the standard equivalent versions (see page 1/2).
(2) Cards to replace the memory card supplied as standard with each processor, used for:
- Backing up the program, constants, symbols and data
- File storage
- Activation of class B10 Web server
BMXP3420302H
BMXRMS008/128MPF
BMXXCAUSBH0pp
BMXP342020H
Modicon M340
automation platform
Dedicated parts for severe environments
“Ruggedized” processor modules
Introduction (continued),
references
BMXP341000H
1
2
3
4
5
6
7
8
9
10
6/4
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Communication:
page 3/2 Software:
page 4/2
“Ruggedized” power supply modules
BMXXBPpp00H racks are equipped with a power supply module. These modules
are inserted in the rst two slots of each rack (marked CPS).
The available power values given below in bold italic correspond to operation at
- 25°C and + 70°C (see temperature derating curves on our website
www.schneider-electric.com).
The power required to supply each rack depends on the type and number of
modules installed in the rack. It is therefore necessary to draw up a power
consumption table for each rack to determine which is the appropriate
BMXCPSppp0H power supply module for your requirements (see page 7/16).
Power supply modules (1)
Line supply Available power (2) Reference Weight
kg
3.3 V c
(3)
24 V c
rack
(3)
24 V c
sensors
(4)
Total
24 to 48 V c
isolated
15 W
11.3 W
31.2 W
23.4 W
31.2 W
23.4 W
BMXCPS3020H 0.340
100 to 240 V a 15 W
11.3 W
31.2 W
23.4 W
21.6 W
16.2 W
36 W
27 W
BMXCPS3500H 0.360
Standard separate part
Description Type Composition Reference Weight
kg
Set of 2
removable
connectors
Spring-type One 5-way terminal
block and one 2-way
terminal block
BMXXTSCPS20 0.015
Standard replacement part
Description Type Composition Reference Weight
kg
Set of 2
removable
connectors
Cage clamp One 5-way terminal
block and one 2-way
terminal block
BMXXTSCPS10 0.020
(1) Includes a set of 2 cage clamp removable connectors BMXXTSCPS10.
(2) The combined power consumed on each voltage (3.3 V c and 24 V c) cannot exceed the
maximum power of the module. See the power consumption table on page 7/16
.
(3) 3.3 V c and 24 V c rack voltages for powering Modicon M340 PAC modules.
(4) 24 V c sensor voltage for powering the input sensors (voltage available via the 2-way
removable connector on the front panel).
BMXCPS3020H
BMXCPS3500H
Modicon M340
automation platform
Dedicated parts for severe environments
‘‘Ruggedized’ power supply modules
References
1
2
3
4
5
6
7
8
9
10
6/5
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Communication:
page 3/2 Software:
page 4/2
BMXXBP0400H
“Ruggedized” racks
Description Type of module
to be inserted
No. of
slots (1)
Power
consump-
tion
(2)
Reference Weight
kg
Ruggedized racks BMXCPS power supply,
BMXP34processor, I/O modules and
application-specic (counter and
communication) modules
4 1 W
BMXXBP0400H
0.630
6 1.5 W
BMXXBP0600H
0.790
8 2 W
BMXXBP0800H
0.950
Description Use Reference Weight
kg
Ruggedized rack
expansion module
(3)
Standard module to be installed in each rack (XBE slot) Used to
daisy chain up to 4 racks
BMXXBE1000H
0.178
Standard accessories for racks
Description For use with Sold in
lots of
Reference Weight
kg
Shielding
connection kits
are comprised of:
A metal bar-
2 support bases-
BMXXBP0400H rack
BMXXSP0400
0.280
BMXXBP0600H rack
BMXXSP0600
0.310
BMXXBP0800H rack
BMXXSP0800
0.340
Spring clamping
rings
Cables, cross-section 1.5 to 6 mm210 STBXSP3010 0.050
Cables, cross-section 5 to 11 mm210 STBXSP3020 0.070
Protective covers
(replacement parts)
Unoccupied slots on BMXXBPpp00H rack 5BMXXEM010 0.005
Standard cordsets and connection accessories
Description Use Composition Type of
connector
Length Reference Weight
kg
Bus X extension
cordsets
maximum length
30 m max.
(3)
Between two
BMXXBE1000H
rack expansion
modules.
2 x 9-way SUB-D
connectors
Angled 0.8 m
BMXXBC008K
0.165
1.5 m
BMXXBC015K
0.250
3 m
BMXXBC030K
0.420
5 m
BMXXBC050K
0.650
12 m
BMXXBC120K
1.440
Straight 1 m
TSXCBY010K
0.160
3 m
TSXCBY030K
0.260
5 m
TSXCBY050K
0.360
12 m
TSXCBY120K
1.260
18 m
TSXCBY180K
1.860
28 m
TSXCBY280K
2.860
Cable reel
(3)
Length of cable to
be tted with
TSXCBYK9
connectors.
Ends with ying leads,
2 line testers
100 m
TSXCBY1000
12.320
Description Use Composition Sold in
lots of
Reference Weight
kg
Line terminator Required on both
BMXXBPppp0H
modules at each
end of the daisy
chain
2 x 9-way SUB-D
connectors marked A/ and /B
2
TSXTLYEX
0.050
Bus X
straight connectors
For ends of
TSXCBY1000
cables
2 x 9-way SUB-D
straight connectors
2
TSXCBYK9
0.080
Connector
assembly kit
Fitting TSXCBYK9
connectors
2 crimping pliers, 1 pen
(4)
TSXCBYACC10
(1) Number of slots taking the processor module, I/O modules and application-specic modules (excluding power
supply module).
(2) Power consumption of anti-condensation resistor(s)
(3) Modules and cordsets operate properly at temperatures at or above - 25°C.
(4) To t the connectors on the cable, you will also need a wire stripper, a pair of scissors and a digital ohmmeter.
BMXXBE1000H
Angled connector on
extension cordsets
TSXTLYEX
Modicon M340
automation platform
Dedicated parts for severe environments
‘‘Ruggedized’ racks and rack expansion module
References
BMXXSP0p00 + BMXXSP30p0
1
2
3
4
5
6
7
8
9
10
6/6
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Communication:
page 3/2 Software:
page 4/2
References Modicon M340
automation platform
Dedicated parts for severe environments
‘‘Ruggedized’ discrete I/O modules
References
“Ruggedized” discrete input modules
Type of
current
Input voltage Connection via
(1)
IEC/EN
61131-2
conformity
No. of channels
(common)
Reference Weight
kg
c24 V (positive
logic)
Screw or spring-type 20-way
removable terminal block
Type 3 16 isolated inputs
(1 x 16)
BMXDDI1602H 0.115
24 V (negative
logic)
Screw or spring-type 20-way
removable terminal block
Non-IEC 16 isolated inputs
(1 x 16)
BMXDAI1602H 0.115
48 V (positive
logic)
Screw or spring-type 20-way
removable terminal block
Type 1 16 isolated inputs
(1 x 16)
BMXDDI1603H 0.115
a24 V Screw or spring-type 20-way
removable terminal block
Type 1 16 isolated inputs
(1 x 16)
BMXDAI1602H 0.115
48 V Screw or spring-type 20-way
removable terminal block
Type 3 16 isolated inputs
(1 x 16)
BMXDAI1603H 0.115
100 to 120 V Screw or spring-type 20-way
removable terminal block
Type 3 16 isolated inputs
(1 x 16)
BMXDAI1604H 0.115
Ruggedized discrete output modules
Type of
current
Output voltage Connection via
(1)
IEC/EN
61131-2
conformity
No. of channels
(common)
Reference Weight
kg
c
transistor 24 V/0.5 A
(positive logic)
Screw or spring-type 20-way
removable terminal block
Yes 16 protected outputs
(1 x 16)
BMXDDO1602H 0.120
24 V/0.5 A
(negative logic)
Screw or spring-type 20-way
removable terminal block
16 protected outputs
(1 x 16)
BMXDDO1612H 0.120
a triac 100 to 240 Screw or spring-type 20-way
removable terminal block
16 outputs
(4 x 4)
BMXDAO1605H 0.140
c or a
relay
12 to 24 V c/2 A
24 to 240 V a/2
A
Screw or spring-type 20-way
removable terminal block
Yes
8 non-protected
outputs
(without common)
BMXDRA0805H 0.145
24 V c/2 A,
240 V a/2 A
Screw or spring-type 20-way
removable terminal block
Yes
16 non-protected
outputs
(2 x 8)
BMXDRA1605H 0.150
Ruggedized mixed discrete I/O modules
Number
of I/O
Connection via
(1)
No. of input channels
(common)
No. of output
channels
(common)
IEC/EN
61131-2
conformity
Reference Weight
kg
16 Screw or
spring-type
20-way
removable
terminal block
8 (positive logic)
(1 x 8)
8, transistor
24 V c /0.5 A
(1 x 8)
Inputs, type 3 BMXDDM16022H 0.115
8, 24 V c or 24 to
240 V a relay
(1 x 8)
Inputs, type 3 BMXDDM16025H 0.135
Standard removable connection blocks
Description Use Type Reference Weight
kg
20-way removable
terminal blocks
For module with 20-way removable
terminal block
Cage clamp BMXFTB2000 0.093
Screw clamp BMXFTB2010 0.075
Spring-type BMXFTB2020 0.060
Standard preformed cordsets for I/O modules with removable terminal block
Description Composition Length Reference Weight
kg
Pre-assembled cordsets
with one end with ying
leads
One 20-way spring-type removable
terminal block (BMXFTB2020)
One end with color-coded ying leads
3 m BMXFTW301 0.850
5 m BMXFTW501 1.400
10 m BMXFTW1001 2.780
(1) By connector, module supplied with cover(s)
BMXDpI 160pH
BMXDRA
0805H/1605H
BMXDDM 1602pH
BMXFTB2p00
BMXDDO16p2H
1
2
3
4
5
6
7
8
9
10
6/7
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Communication:
page 3/2 Software:
page 4/2
Modicon M340
automation platform
Dedicated parts for severe environments
‘‘Ruggedized’ analog I/O modules
References (continued)
References
“Ruggedized” analog input modules
Type of inputs Input
signal range
Resolution Connection No. of
channels
Reference Weight
kg
Isolated high-level
inputs
± 10 V, 0 to 10 V,
0 to 5 V, 1 to 5 V, ± 5
V
0 to 20 mA,
4 to 20 mA, ± 20 mA
16 bits Via cage clamp,
screw clamp
or spring-type
removable
terminal block
4
high-speed
channels
BMXAMI0410H
0.143
Isolated low-level
inputs
Temperature probe,
thermocouple
± 40 mV, ± 80 mV,
± 160 mV,
± 320 mV,
± 640 mV, ± 1.28 V
15 bits +
sign
40-way connector 4 channels
BMXART0414H
0.135
8 channels
BMXART0814H
0.165
Ruggedized analog output module
Type of outputs Output signal
range
Resolution Connection No. of
channels
Reference Weight
kg
Isolated
high-level outputs
± 10 V,
0 to 20 mA, 4 to 20
mA
16 bits Via cage clamp,
screw clamp
or spring-type
removable
terminal block
2 channels
BMXAMO0210H
0.144
Ruggedized mixed analog I/O module
Type of outputs Signal range Resolution Connection No. of
channels
Reference Weight
kg
Mixed I/O,
non-isolated
± 10 V, 0 to 10 V,
0 to 5 V, 1 to 5 V,
0 to 20 mA, 4 to 20
mA
14 bits or 12
bits
depending
on the
range
Via cage clamp,
screw clamp or
spring-type
removable
terminal block
I: 4
channels
Q: 2
channels
BMXAMM0600H
0.155
Standard connection accessories for analog modules (1)
Description For use with
modules
Type, composition Length Reference Weight
kg
20-way removable
terminal blocks
BMXAMI0410H
BMXAMO0210H
BMXAMM0600H
Cage clamp
BMXFTB2000
0.093
Screw clamp
BMXFTB2010
0.075
Spring-type –
BMXFTB2020
0.060
Pre-assembled
cordsets
BMXAMI0410H
BMXAMO0210H
BMXAMM0600H
One 20-way removable
terminal block (BMXFTB2020)
One end with color-coded
ying leads
3 m
BMXFTW301S
0.470
5 m
BMXFTW501S
0.700
BMXART0414H
BMXART0814H (2)
One 40-way connector
One end with color-coded
ying leads
3 m
BMXFCW301S
0.480
5 m
BMXFCW501S
0.710
Modicon Telefast ABE7 pre-wired system
Modicon Telefast
ABE7 sub-bases
BMXAMI0410H Distribution of isolated power
supplies
Delivers 4 protected isolated
power supplies for
4 to 20 mA inputs
Direct connection of 4 inputs
ABE7CPA410
0.180
BMXART0414H
BMXART0814H
Connection and provision
of cold-junction compensation
for thermocouples
Direct connection of 4 inputs
ABE7CPA412
0.180
Preformed cordsets for
Modicon Telefast
ABE7CPA41p
BMXAMI0410H
BMXAMO0210H
One 20-way removable terminal
block and one 25-way SUB-D
connector for ABE7CPA410/
CPA21 sub-base
1.5 m
BMXFCA150
0.320
3 m
BMXFCA300
0.500
5 m
BMXFCA500
0.730
BMXART0414H
BMXART0814H
One 40-way connector and
one 25-way SUB-D connector
for ABE7CPA412 sub-base
1.5 m
BMXFCA152
0.330
3 m
BMXFCA302
0.510
5 m
BMXFCA502
0.740
(1) The shielding on the cordsets carrying the analog signals is connected to the BMXXSPpp00
shielding connection kit mounted under the rack holding the analog modules (see page 1/11).
(2) The BMXART0814H 8-channel module requires two ABE7CPA412 sub-bases and two
BMXFCApp2 cordsets.
BMXAMp0pp0H
BMXART0414H
BMXFTB20p0
BMXFTWp01S
BMXFCApp0
BMXFCApp2
ABE7CPA41p
1
2
3
4
5
6
7
8
9
10
6/8
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Communication:
page 3/2 Software:
page 4/2
Communication
BMXNOE0100H/0110H “ruggedized” Ethernet communication modules
Description Data rate Transparent Ready
Class
Reference Weight
kg
Ethernet Modbus/
TCP network
modules
10/100 Mbps B30 BMXNOE0100H 0.200
C30 BMXNOE0110H 0.200
BMXNOM0200H ruggedized serial link module
Description Protocol Physical layer Reference Weight
kg
Serial link module
2-channels
Modbus
master/slave
RTU/ASCII,
Character mode,
Modem
GSM/GPRS
1 non-isolated RS
232 channel (SL0)
2 isolated RS 485
channels
(SL0 and SL1)
BMXNOM0200H 0.230
RTU BMXNOR0200H ruggedized communication module
Description Protocols Physical
layer
Reference Weight
kg
RTU
communication
module
Modbus TCP,
IEC 60870-5-104
or DNP3 IP
(client or server)
1 Ethernet port
10BASE-T/
100BASE-TX
BMXNOR0200H 0.205
IEC 60870-5-101
or DNP3 serial
(master or slave)
1 non-isolated
RS 232/485
serial link port
Ruggedized Probus DP network gateway
Description Protocols Physical
layer
Reference Weight
kg
Probus
Remote Master
(PRM) module
Modbus TCP 1 Ethernet switch,
2 ports
10BASE-T/
100BASE-TX
TCSEGPA23F14FK
Probus DP V1
and Probus PA
(via gateway)
1 isolated RS 485
Probus DP port
Standard connection accessory
Designation Description RS 232
interface
Reference Weight
kg
Cordset for
DCE terminal
(modem, etc.)
Equipped with 1 x
RJ45 connector
and 1 x 9-way male
SUB-D connector
Length 3 m
Simplied 4-wire (RX,
TX, RTS and CTS)
TCSMCN3M4M3S2 0.150
8-wire
(except RI signal)
TCSXCN3M4F3S4 0.165
BMXNOE0100H/0110H
References (continued) Modicon M340
automation platform
Dedicated parts for severe environments
‘‘Ruggedized’ communication modules and
network gateway
BMXNOM0200H
BMXNOR0200H
TCSEGPA23F14FK
1
2
3
4
5
6
7
8
9
10
6/9
Processors:
page 1/2 I/O:
pages 2/2 and2/14 Communication:
page 3/2 Software:
page 4/2
Counter
BMXEHC0200H/0800H “ruggedized” counter modules
Description No. of
channels
Specications Reference Weight
kg
Counter modules
for 24 V c 2 and
3 wire sensors and 10/30 V
c incremental encoders with
push-pull outputs
2 60 kHz counting BMXEHC0200H 0.112
8 10 kHz counting
BMXEHC0800H 0.113
Standard connection accessories (1)
Description Composition Unit reference Weight
kg
Connector kit
for BMXEHC0200H
module
Two 16-way connectors and
one 10-way connector
BMXXTSHSC20 0.021
20-way removable
terminal blocks
for BMXEHC0800H
module
Cage clamp BMXFTB2000 0.093
Screw clamp BMXFTB2010 0.075
Spring-type BMXFTB2020 0.060
Shielding connection kits
for BMXEHC0200H/0800H
modules
A metal bar and two support bases
for mounting on rack
See page 1/11
(1) The shielding on the cordsets carrying the counter signals is connected to the BMXXSPpp00
shielding connection kit mounted under the rack holding the BMXEHC0200H module
(see page 1/11).
BMXEHC0200H BMXEHC0800H
BMXFTB20p0
Modicon M340
automation platform
Dedicated parts for severe environments
‘‘Ruggedized’ counter modules
References (continued)
1
2
3
4
5
6
7
8
9
10
6/10
1
2
3
4
5
6
7
8
9
10
7/1
7.1 - Technical appendices
Standards, certications and environmental conditions
b ..................7/2
Certications for automation products and EC regulations
b .................7/6
7.2 - Compatibility with sensors
OsiSense
b XU photo-electric sensors ................................7/8
OsiSense XS inductive proximity sensors
b ............................7/10
7.3 - Power consumption table
Introduction
b ...................................................7/16
Calculation sheet
b. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7/17
7.4 - Dedicated services offer for your installed base
Operation services
b ..............................................7/18
Modernization services
b ..........................................7/19
Customization services
b ..........................................7/19
7.5 - Index
Product reference index
b .........................................7/20
Services
Contents chapter 7
1
2
3
4
5
6
7
8
9
10
7/2
Standards and certications
Modicon M340 PACs have been developed to conform to the principal national
and international standards concerning electronic equipment for industrial
automation systems.
Requirements specic to programmable controllers: functional Specications,
b
immunity, resistance, safety, etc.: IEC/EN 61131-2, CSA 22.2 142, UL 508.
Merchant navy requirements of the main international bodies (with ABS, BV, DNV,
b
GL, LR, RINA, RMRS): IACS (International Association of Classication Societies).
Compliance with European Directives:
b
Low Voltage: 2006/95/EC, v
Electromagnetic Compatibility: 2004/108/EC. v
Electrical qualities and self-extinguishing capacity of insulating materials: UL
b
746C, UL 94.
Hazardous areas classication: CSA 22.2 No. 213, Class I, Division 2, Groups A,
b
B, C and D.
Specications
Service conditions and recommendations relating to environment
Temperature Operation ° C 0 to + 60
Storage ° C - 40 to + 85
Relative humidity Operation %93 to 95 without condensation according to IEC/EN 60068-2-30 Db
Storage %93 to 95 without condensation according to IEC/EN 60068-2-30 Db
Altitude m 0 to 4000,
temperature derating from 3000 m: 1 °C / 400 m, equals to + 55 °C at 4000 m
Supply voltage
a: according to
IEC/EN 61131-2
c: according to IACS E10
battery without charge
Power supply modules
BMXCPS2010 BMXCPS3020 BMXCPS3540T BMXCPS2000 BMXCPS3500
Nominal voltage Vc 24 c 24 to 48 c 24 a 100 to 240 a 100 to 240
Limit voltages c 18 to 31.2 c 18 to 62.4 c 23.3 to 24.7 a 85 to 264 a 85 to 264
Nominal frequencies Hz – – – 50/60 50/60
Limit frequencies Hz – – – 47/63 47/63
Protective treatment of Modicon Premium PACs
Modicon M340 PACs meet the requirements of “TC” treatment (Treatment for
Climates).
For installations in industrial production workshops or environments corresponding to
“TH” treatment (Treatment for Hot and humid environments), Modicon M340 PACs
are embedded in envelopes with a minimum IP 54 protection, in compliance with IEC/
EN 60664 and NF C 20 040.
Modicon M340 PACs offer protection to IP 20 level and protection against pins
(encloset equipement) (1). They can be installed without an envelope in reserved-
access areas up to and including pollution level 2 (control room with no dust-
producing machine or activity). The pollution level 2 does not take into account more
severe environmental conditions such as: air pollution by dust, smoke, corrosive or
radioactive particles, vapors or salts, attack by fungi, or insects.
(1) In the case where a position is not occupied by a module, install a BMXXEM010
protection cover.
Standards and
certications Modicon M340
automation platform
Standards, certications and
environment conditions
1
2
3
4
5
6
7
8
9
10
7/3
Environment tests Modicon M340
automation platform
Standards, certications and
environment conditions
Environment tests
Name of test Standards Levels
Immunity to LF interference (e) (1)
Voltage and frequency variation IEC/EN 61000-4-11
IACS E10 / IEC 60092-504
0.85 Un/0.95 Fn for 30 minutes; 1.10 Un/1.05 Fn for 30 minutes;
0.8 Un/0.9 Fn for 1,5/5 seconds; 1.2 Un/1.1 Fn for 1,5/5 seconds
Direct voltage variation IEC/EN 61131-2
IEC/EN 61000-4-11
IEC 60092-504
IACS E10 (battery without
charge)
0.85 Un to 1.2 Un for 30 minutes with 5% ripple (peak values)
Harmonic 3 IEC/EN 61131-2 10 % Un; 0° for 5 min to 180° for 5 min
Inter harmonic IACS E10 / IEC 60092-504 H2 to H200 - 10 % (H15), - 10 % to 1 % (H15 to H100) and 1 % (H100 to H200)
Short momentary interrupt IEC/EN 61131-2
IEC/EN 61000-4-11/-6-2
10 ms with a supply; 1 ms with c supply
Voltage shut-down/start-up IEC/EN 61131-2 Un-0-Un; Un for 60 s; 3 cycles separated by 10 s
Un-0-Un; Un for 5 s; 3 cycles separated by 1 to 5 s
Un-0.9-Udl; Un for 60 s; 3 cycles separated by 1 to 5 s
Where:
Un: nominal voltage
Fn: nominal frequency
Udl: detection level when powered
Name of test Standards Levels
Immunity to HF interference. (e) (1)
Damped oscillatory wave IEC/EN 61000-4-18
IEC/EN 61131-2 Zone C
a / c main supply, a auxiliary supply, discrete a I/O (unshielded): 2.5 kV in common mode, 1
kV in differential mode
c auxiliary supply, discrete a I/O (unshielded) and analog I/O: 1 kV in common mode, 0.5 kV in
differential mode
Shielded cable: 0.5 kV in common mode
Electrical fast transient bursts EC/EN 61000-4-4
IEC 61131-2 / IACS E10
a / c main and auxiliary supplies, discrete a I/O (unshielded): 2 kV in wire mode, 2 kV in
common mode
Discrete c I/O (unshielded), analog I/O and shielded cable: 1 kV in common mode
Surge IEC/EN 61000-4-5
IEC/EN 61131-2 Zone B
IACS E10
a / c main and auxiliary supplies, discrete a I/O (unshielded): 2 kV in common mode, 1 kV in
differential mode
Discrete a I/O (unshielded) and analog I/O: 0.5 kV in common mode, 0.5 kV in differential mode
Shielded cable: 1 kV in common mode
Electrostatic discharges IEC/EN 61000-4-2
IEC/EN 61131-2 Zone B
IACS E10
6 kV contact, 8 kV air
Radiated electromagnetic eld IEC/EN 61000-4-3 15 V/m: 80 MHz to 2 GHz
Sinusoidal modulation amplitude 80 %/1 kHz + internal clock frequency
Conducted interference induced
by radiated eld
IEC/EN 61000-4-6
IEC/EN 61131-2
IACS E10
10 V ; 0,15 MHz to 80 MHz
Sinusoidal modulation amplitude 80%/1 kHz + spot frequency
Electromagnetic emissions (e) (1) (2)
Interference voltage EN 55011, Classe A
IEC/EN 61131-2
IEC/EN 61000-6-4
FCC part 15
150 kHz to 500 kHz quasi-peak 79 dB (µV); average 66 dB (µV)
500 kHz to 30 MHz quasi-peak 73 dB (µV); average 60 dB (µV)
IACS E10 Values according general power distribution zone
Interference eld EN 55011, Classe A
IEC/EN 61131-2
IEC/EN 61000-6-4
FCC part 15
30 MHz to 230 MHz: quasi-peak 40 dB (measurement at 10 m), quasi-peak 50 dB
(measurement at 3 m)
230 MHz to 2 GHz: quasi-peak 47 dB (measurement at 10 m), quasi-peak 57 dB (measurement
at 3 m)
IACS E10 Values depending on general power distribution zone
(1) Install and wire devices in compliance with the instructions provided in the manual “Grounding
and Electromagnetic Compatibility of PAC systems”, pdf format on CD-ROM support included in
Unity Pro/PL7 software or on DVD UNYUSE909CDM reference (see page 4/23).
(2) These tests are performed without a cabinet, with devices mounted on a metal grid and
wired as per the recommendations in the manual “Grounding and Electromagnetic Compatibility
of PAC systems”.
(e): tests required by European directives e. and based on IEC/EN 61131-2 standards.
1
2
3
4
5
6
7
8
9
10
7/4
Environment tests (continued)
Name of test Standards Levels
Immunity to climatic variations
Dry heat IEC/EN 60068-2-2 Bd
IACS E10
60 °C for 16 hours
Cold IEC/EN 60068-2-1 Ab & Ad
IACS E10
0 °C for 16 hours with start at 0°C
Continuous humid heat IEC/EN 60068-2-78 Ca 60 °C with 93 % relative humidity for 96 hours
Cyclical humid heat IEC/EN 60068-2-30 Db 55 °C, 25 °C with 93 to 95 % relative humidity with 2 cycles of 12 hours/12 hours
Cyclical temperature variations IEC/EN 60068-2-14 Na & Nb
IEC/EN 61131-2
0 to 60 °C with 5 cycles of 3 hours/3 hours
Withstand to climatic variations
Dry heat (power off) IEC/EN 60068-2-2 Bb & Bd 85 ° C for 96 hours
Cold (power off) IEC/EN 60068-2-1 Ab & Ad
IEC/EN 60068-2-48
- 40 ° C for 96 hours
Humid heat (power off) IEC/EN 60068-2-30 dB 25 to 60 °C with 93 to 95 % relative humidity; 2 cycles: 12 hours/12 hours
Heat shocks (power off) IEC/EN 60068-2-14 Na & Nb - 40 to 85 °C with 2 cycles of 3 hours/3 hours
Modicon M340
automation platform
Standards, certications and
environment conditions
Environment tests (continued)
1
2
3
4
5
6
7
8
9
10
7/5
Modicon M340
automation platform
Standards, certications and
environment conditions
Environment tests (continued)
Name of test Standards Levels
Immunity to mechanical constraints (1) (power on)
Sinusoidal vibrations IEC/EN 60068-2-6 Fc
IACS E10
3 Hz to 100 Hz/1 mm amplitude / 0.7 g, transistion frequency 13.2 Hz
Endurance to resonance frequency 90 min/axis
Application coefcient < 10
Sinusoidal vibrations
(Class 3M7)
IEC/EN 60068-2-6 Fc
IEC/EN 61131-2
Specic prole
5 to 150 Hz with 10 mm amplitude / 3 g, transistion frequency 9 Hz
Endurance: 10 cycles of 1 octave/min
Shocks IEC/EN 60068-2-27 Ea 30 g - 11 ms; 3 shocks/direction/axis
(2)
Bumps IEC/EN 60068-2-29 Eb 25 g - 6 ms; 100 shocks/direction/axis
(3)
Plugging / unplugging IEC/EN 61131-2 For modules and connectors
50 operations for permanent connections
500 operations for non permanent connections
Withstand to mechanical constraints (power off)
Flat freefall IEC/EN 60068-2-32 Ed
method 1
IEC/EN 61131-2
10 cm/2 falls
Controlled position freefall
(for handheld product)
IEC/EN 60068-2-31 Ec
IEC/EN 61131-2
30 ° or 10 cm/2 falls
Random freefall
(equipment in packaging)
IEC/EN 60068-2-32
method 1
IEC/EN 61131-2
1 m/5 falls
Vibrations, transports
(Class 2M3)
IEC/EN 60721-4-2
IEC/EN 60068-2-64 Fh
Stationary vibrations, random: 5 m2/s3 from 10 to 100 Hz, 7 dB/octave from 100 to 200 Hz,
1 m2/s3 de 200 to 2000 Hz, 30 min duration per axe
Equipment and personnel safety (1) (e)
Dielectric strength UL 508/CSA 22-2 No.142 /
FM
IEC/EN 61131-2
2 Un + 1000 V / 1 min
Insulation resistance UL 508/CSA 22-2 No.142 /
FM
IEC/EN 61131-2
Un y 50 V: 10
50 V y Un y 250 V: 10 MΩ
Continuity of earth ground UL 508/CSA 22-2 No.142 /
FM
IEC/EN 61131-2
30 A for 2 min, R < 0,1 Ω
Leakage current IEC/EN 61131-2 I < 3.5 mA after disconnecting
Protection offered by enclosures IEC/EN 61131-2 IP 20 and protection against standardize pins
Withstand to impacts UL 508/CSA 22-2 No.142 /
FM
IEC/EN 61131-2
500 g sphere: fall from 1.3 m
Stored energy injury risk IEC/EN 61131-2 After 10 s, max. 37 % Un
Overload UL 508/CSA 22-2 No.142 /
FM
IEC/EN 61131-2
50 cycles 1 s / 9 s to Un and 1.5 In
Endurance UL 508/CSA 22-2 No.142 /
FM
IEC/EN 61131-2
12 cycles 100 ms / 100 ms, 988 cycles 1 s / 1 s and 5000 cycles 1 s / 9 s to Un and In
Temperature rise IEC/EN 61131-2/UL 508
CSA 22-2 No.142/UL 1604
CSA 22-2 No.213 / FM
Ambient temperature 60 °C
(1) Install, wire and maintain devices in compliance with the instructions provided in the manual “Grounding and Electromagnetic Compatibility of PAC Systems”.
(2) In case of using fast actuators (response time y 15 ms) driven by relay outputs: 15 g - 11 ms; 3 shocks/direction/axis
(3) In case of using fast actuators (response time y 15 ms) driven by relay outputs: 15 g - 6 ms; 100 bumps/direction/axis.
(e): tests required by European directives e. and based on IEC/EN 61131-2 standards.
Environment tests (continued)
1
2
3
4
5
6
7
8
9
10
7/6
Some countries require certain electrical components to undergo certication by
law. This certication takes the form of a certicate of conformity to the relevant
standards and is issued by the ofcial body in question. Where applicable, label
certied devices accordingly. Use of electrical equipment on board merchant vessels
generally implies that it has gained prior approval (i.e. certication) by certain
shipping classication societies.
Abbreviated
name
Certication body Country
CSA Canadian Standards Association Canada
C-Tick Australian Communication Authority Australia, New Zealand
GOST Scientic research institute for GOST standards CIS, Russia
UL Underwriters Laboratories USA
Abbreviated
name
Classication society Country
IACS International Association of Classication Societies International
ABS American Bureau of Shipping USA
BV Bureau Veritas France
DNV Det Norske Veritas Norway
GL Germanischer Lloyd Germany
LR Lloyd’s Register UK
RINA Registro Italiano Navale Italy
RMRS Russian Maritime Register of Shipping CIS, Russia
RRR Russian River Register
The tables below provide an overview of the situation as of 1st June 2010 in terms of
which certications (listed next to their respective bodies) have been granted or are
pending for our automation products.
Up-to-date information on which certications have been obtained
by Schneider Electric branded products can be viewed on our website:
www.schneider-electric.com.
Product certications
Certications
C-Tick Hazardous
locations (1)
Class I, div 2
BG SIMTARS AS-
Interface
Certied
Certication pending
UL CSA ACA GOST INERIS TÜV Rheinland
USA Canada Australia CIS, Russia USA, Canada Europe Germany Australia Europe
Modicon OTB
Modicon STB FM Cat. 3 G (2) (5)
Modicon Telefast ABE7
ConneXium(2)
Magelis iPC/GTW (3) (2) (2) UL (2) (5)
Magelis XBTGT (2) (2) CSA/UL Cat. 3 G-D/ 3D
(2) (5)
Magelis XBTGK (3) CSA/UL
Magelis XBTN/R/RT CSA/UL Cat. 3 G-D
(5)
Modicon M340CSA IEC Ex ia I (2)
(2) (6)
(2)
Modicon Momentum
Modicon Premium(2) CSA (2) (2) (2)
Modicon Quantum(2) FM (2)
Modicon Quantum Safety (2) CSA SIL 2, SIL 3 (7)
Preventa XPSMF SIL 3 (7)
Modicon TSX Micro(2) (2)
Phaseo(3)
Twido(4) (4) CSA/UL (4) (2)
(1) Hazardous locations: According to UL 1604, CSA 22.2 No. 213 and FM 3611, certied
products are only approved for use in hazardous locations categorized as Class I, division 2,
groups A, B, C and D, or in non-classied locations.
(2) Depends on product; please visit our website: www.schneider-electric.com.
(3) North American certication cULus (Canada and United States).
(4) Except for AS-Interface module TWD NOI 10M3; e only.
(5) For ATEX zones not covered by this specication, Schneider Electric offers a solution under
the CAPP program (Collaborative Automation Partner Program). Please consult our Customer
Care Center.
(6) Certied by Test Safe.
(7) According to IEC 61508. Certied by TÜV Rheinland for integration into a safety function of
up to SIL 2 or SIL 3.
Technical appendices
Certications for automation products
EC regulations
Services
1
2
3
4
5
6
7
8
9
10
7/7
Merchant navy certications
Shipping classication societies
Korean
Register of
Shipping
Certied
Certication pending
ABS BV DNV GL KRS LR RINA RMRS RRR PRS
USA France Norway Germany Korea UK Italy CIS CIS Poland
Modicon OTB
Modicon STB (1) (2) (2) (2) (2) (2) (2) (2) (2)
Modicon Telefast ABE7
ConneXium(2) (2) (2)
Magelis iPC/GTW (2)
Magelis XBTGT
Magelis XBTGK
Magelis XBTN/R
Magelis XBTRT
Modicon M340(2) (2) (2) (2) (2) (2) (2) (2)
Modicon Momentum
Modicon Premium(2) (2) (2) (2) (2) (2)
Modicon Quantum(2) (2) (2) (2) (2) (2) (2)
Modicon TSX Micro
Phaseo
Twido(2) (2) (2)
(1) Also covers US Navy requirements ABS-NRV part 4.
(2) Depends on product; please visit our website: www.schneider-electric.com.
(3) Except XBTGT2430/2930/5430/1105/1135/1335.
EC regulations
European Directives
The open nature of the European markets assumes harmonization between
the regulations set by different European Union member states.
European Directives are texts whose aim is to remove restrictions on free
circulation of goods and are applied within the European Union states.
Member states are obligated to incorporate each Directive into their national
legislation, while at the same time withdrawing any regulation that contradicts it.
Directives - and particularly those of a technical nature with which we are concerned
- merely set out the objectives to be fullled (referred to as “essential requirements”).
The manufacturer is obligated to implement any and measures to help ensure that
his products meet the requirements of each Directive that applies to his equipment.
As a general rule, the manufacturer certies compliance with essential requirements
of the Directive(s) that apply to his product by applying a e mark.
The e mark has been applied to our products where applicable.
Signicance of the e mark
The appearance of a b e mark on a product indicates the manufacturer's certication
that the product conforms to the relevant European Directives; this is a prerequisite for
placing a product that is subject to the requirements of one or more Directives on the
market and for allowing its free circulation within European Union states.
The b e mark is intended for use by those responsible for regulating national markets.
Where electrical equipment is concerned, conformity to standards indicates that the
product is t for use.
As far as our products are concerned, one or more Directives are likely to apply in
each case; in particular:
The Low Voltage Directive (2006/95/EC) b.
The Electromagnetic Compatibility Directive (2004/108/EC) b.
The ATEX b e Directive (94/9/EC).
Technical appendices
Certications for automation products
EC regulations
Services
1
2
3
4
5
6
7
8
9
10
7/8
Photo-electric sensors c Inputs, BMXDDI c Inputs, BMXDDM c Inputs, BMXAMI a Inputs, BMXDAI
Type Reference 1602 1603 1604T 3202K 6402K 16022 16025 3202K 0810 0800 1602 1603 1604 0805
General purpose
Design Ø
18
Metal 3 wire, PNP 24V XUB0/1/2/4/5/9BpPppp
3 wire, NPN 24V XUB0/1/2/4/5/9BpNppp
Plastic 3 wire, PNP 24V XUB0/1/2/4/5/9ApPppp
3 wire, NPN 24V XUB0/1/2/4/5/9ApNppp
Design Miniature 3 wire, PNP 24V XUM0/2/5/9APpppp
3 wire, NPN 24V XUM0/2/5/9ANpppp
Compact 50x50 3 wire, PNP 24V XUK1/2/5/8/9APppp
3 wire, NPN 24V XUK1/2/5/8/9ANppp
3 wire, programmable PNP/NPN DC XUK0AKppp
5 wire, programmable AC/DC XUK0/1/2/5/8/9AR
Compact 92x71 3 wire, programmable PNP/NPN DC XUX0/1/2/5/8/9AK
5 wire, programmable AC DC XUX0/1/2/5/8/9AR
Application
Material
handling
Optical fork 3 wire, PNP 24V XUVRppppPpp
3 wire, NPN 24V XUVRppppNpp
3 wire, PNP 24V XUVAppppPpp
3 wire, NPN 24V XUVAppppNpp
4 wire, PNP or NPN 24V XUYFppppp
4 wire, PNP or NPN 24V XUVU06ppp
4 wire, PNP or NPN 24V XUVKppp
3 wire, PNP 24V XUVHppp
3 wire, NPN 24V XUVJppp
4 wire, PNP or NPN 24V XUVFppp
Packaging Fiber 4 wire, PNP or NPN 24V XUYDCFppp
Compact 4 wire, PNP or NPN 24V XURK
M 18, threaded 3 wire, PNP 24V XU5M18U1D
Fiber 4 wire, PNP or NPN 24V XUYAFLppp
M 18, threaded 3 wire, PNP 24V XUBTpPppp
3 wire, NPN 24V XUBTpNppp
Compact 4 wire, PNP or NPN 24V XUKTppp
3 wire, PNP 24V XUKC1Nppp
3 wire, NPN 24V XUKC1Pppp
3 wire, PNP 24V XURC3Pppp
3 wire, NPN 24V XURC3Nppp
4 wire, PNP or NPN 24V XUMWppp
M 18, threaded 3 wire, PNP 24V XUB0SPppp
3 wire, NPN 24V XUB0SNppp
3 wire, PNP 24V XUpN18Pppp
3 wire, NPN 24V XUpN18Nppp
M 8, threaded 3 wire, PNP 24V XUAHppp
3 wire, NPN 24V XUAJppp
Miniature 3 wire, PNP 24V XUYPppppPpp
3 wire, NPN 24V XUYPppppNpp
3 wire, PNP 24V XUM2/5/9BPppp
3 wire, NPN 24V XUM2/5/9BNppp
3 wire, PNP 24V XUYppp929pp
Hoisting M 18, threaded 3 wire, PNP 24V XUBLBPppp
3 wire, NPN 24V XUBLBNppp
Compact 2 wire 4 to 20 mA ; 3 wire 0 to 10V XUJK803538
M 18, threaded 2 wire 4 to 20 mA XU5M18AB20D
PNP, 2 wire 4 to 20 mA XU2M18AB20D
Compact PNP, 2 wire 4 to 20 mA XUYPppp925
4 wire, PNP or NPN 24V XUYPSppp
Fiber 3 wire, PNP 24V XUDApPppp
3 wire, NPN 24V XUDApNppp
4 wire, PNP or NPN 24V XUYAFppp
Other formats 3 wire, programmable PNP/NPN DC XUC2/8/9AKppp
5 wire, programmable AC/DC XUC2/8/9ARCppp
3 wire, PNP 24V XULHppp
3 wire, NPN 24V XULJppp
2 wire, AC XULAppp
5 wire, programmable AC/DC XULMppp
3 wire, programmable PNP/NPN DC XUYBpppS
5 wire, programmable AC/DC XUYBpppR
M 18, threaded 2 wire, AC/DC XU5/8/9M18MAppp
Compatible
Non compatible
Compatibility Modicon M340
automation platform
Inputs and OsiSense XU photo-electric sensors
1
2
3
4
5
6
7
8
9
10
7/9
Photo-electric sensors c Inputs, BMXDDI c Inputs, BMXDDM c Inputs, BMXAMI a Inputs, BMXDAI
Type Reference 1602 1603 1604T 3202K 6402K 16022 16025 3202K 0810 0800 1602 1603 1604 0805
General purpose
Design Ø
18
Metal 3 wire, PNP 24V XUB0/1/2/4/5/9BpPppp
3 wire, NPN 24V XUB0/1/2/4/5/9BpNppp
Plastic 3 wire, PNP 24V XUB0/1/2/4/5/9ApPppp
3 wire, NPN 24V XUB0/1/2/4/5/9ApNppp
Design Miniature 3 wire, PNP 24V XUM0/2/5/9APpppp
3 wire, NPN 24V XUM0/2/5/9ANpppp
Compact 50x50 3 wire, PNP 24V XUK1/2/5/8/9APppp
3 wire, NPN 24V XUK1/2/5/8/9ANppp
3 wire, programmable PNP/NPN DC XUK0AKppp
5 wire, programmable AC/DC XUK0/1/2/5/8/9AR
Compact 92x71 3 wire, programmable PNP/NPN DC XUX0/1/2/5/8/9AK
5 wire, programmable AC DC XUX0/1/2/5/8/9AR
Application
Material
handling
Optical fork 3 wire, PNP 24V XUVRppppPpp
3 wire, NPN 24V XUVRppppNpp
3 wire, PNP 24V XUVAppppPpp
3 wire, NPN 24V XUVAppppNpp
4 wire, PNP or NPN 24V XUYFppppp
4 wire, PNP or NPN 24V XUVU06ppp
4 wire, PNP or NPN 24V XUVKppp
3 wire, PNP 24V XUVHppp
3 wire, NPN 24V XUVJppp
4 wire, PNP or NPN 24V XUVFppp
Packaging Fiber 4 wire, PNP or NPN 24V XUYDCFppp
Compact 4 wire, PNP or NPN 24V XURK
M 18, threaded 3 wire, PNP 24V XU5M18U1D
Fiber 4 wire, PNP or NPN 24V XUYAFLppp
M 18, threaded 3 wire, PNP 24V XUBTpPppp
3 wire, NPN 24V XUBTpNppp
Compact 4 wire, PNP or NPN 24V XUKTppp
3 wire, PNP 24V XUKC1Nppp
3 wire, NPN 24V XUKC1Pppp
3 wire, PNP 24V XURC3Pppp
3 wire, NPN 24V XURC3Nppp
4 wire, PNP or NPN 24V XUMWppp
M 18, threaded 3 wire, PNP 24V XUB0SPppp
3 wire, NPN 24V XUB0SNppp
3 wire, PNP 24V XUpN18Pppp
3 wire, NPN 24V XUpN18Nppp
M 8, threaded 3 wire, PNP 24V XUAHppp
3 wire, NPN 24V XUAJppp
Miniature 3 wire, PNP 24V XUYPppppPpp
3 wire, NPN 24V XUYPppppNpp
3 wire, PNP 24V XUM2/5/9BPppp
3 wire, NPN 24V XUM2/5/9BNppp
3 wire, PNP 24V XUYppp929pp
Hoisting M 18, threaded 3 wire, PNP 24V XUBLBPppp
3 wire, NPN 24V XUBLBNppp
Compact 2 wire 4 to 20 mA ; 3 wire 0 to 10V XUJK803538
M 18, threaded 2 wire 4 to 20 mA XU5M18AB20D
PNP, 2 wire 4 to 20 mA XU2M18AB20D
Compact PNP, 2 wire 4 to 20 mA XUYPppp925
4 wire, PNP or NPN 24V XUYPSppp
Fiber 3 wire, PNP 24V XUDApPppp
3 wire, NPN 24V XUDApNppp
4 wire, PNP or NPN 24V XUYAFppp
Other formats 3 wire, programmable PNP/NPN DC XUC2/8/9AKppp
5 wire, programmable AC/DC XUC2/8/9ARCppp
3 wire, PNP 24V XULHppp
3 wire, NPN 24V XULJppp
2 wire, AC XULAppp
5 wire, programmable AC/DC XULMppp
3 wire, programmable PNP/NPN DC XUYBpppS
5 wire, programmable AC/DC XUYBpppR
M 18, threaded 2 wire, AC/DC XU5/8/9M18MAppp
Compatible
Non compatible
1
2
3
4
5
6
7
8
9
10
7/10
Compatibility Modicon M340
automation platform
Inputs and OsiSense XS inductive proximity
sensors
Proximity sensors c Inputs, BMXDDI c Inputs, BMXDDM c Inputs, BMXAMI a Inputs, BMXDAI
Type Reference 1602 1603 1604T 3202K 6402K 16022 16025 3202K 0810 0800 1602 1603 1604 0805
General purpose
Cylindrical,
ush,
sensing distance
standard,
barel short
Ø 6,5 plain short 3 wire, PNP 24V XS506B1Pppp
3 wire, NPN 24V XS506B1Nppp
2 wire, DC 24V XS506BSCppp
M8, threaded short 3 wire, PNP 24V XS508B1Pppp
3 wire, NPN 24V XS508B1Nppp
2 wire, DC 24V XS508BSCppp
M12, threaded short 3 wire, PNP 24V XS512B1Pppp
3 wire, NPN 24V XS512B1Nppp
2 wire, DC 24V XS512BSD/Cppp
M18, threaded short 3 wire, PNP 24V XS518B1Pppp
3 wire, NPN 24V XS518B1Nppp
2 wire, DC 24V XS518BSD/Cppp
M30, threaded short 3 wire, PNP 24V XS530B1Pppp
3 wire, NPN 24V XS530B1Nppp
2 wire, DC 24V XS530BSD/Cppp
Cylindrical,
ush, sensing
distance standard,
barel long
M8, threaded long 3 wire, PNP 24V-48V XS508BLPppp
3 wire, NPN 24V-48V XS508BLNppp
2 wire, DC 24V-48V XS508B1D/Cppp
M12, threaded long 3 wire, PNP 24V-48V XS512BLPppp
3 wire, NPN 24V-48V XS512BLNppp
2 wire, DC 24V-48V XS512B1D/Cppp
M18, threaded long 3 wire, PNP 24V-48V XS518BLPppp
3 wire, NPN 24V-48V XS518BLNppp
2 wire, DC 24V-48V XS518B1D/Cppp
M30, threaded long 3 wire, PNP 24V-48V XS530BLPppp
3 wire, NPN 24V-48V XS530BLNppp
2 wire, DC 24V-48V XS530B1D/Cppp
M12, threaded long 2 wire, AC/DC XS512B1Mppp
M18, threaded long 2 wire, AC/DC XS518B1Mppp
M30, threaded long 2 wire, AC/DC XS530B1Mppp
Cylindrical,
ush, sensing
distance extending,
barel short
Ø 6,5 plain short 3 wire, PNP 24V XS106B3Pppp
3 wire, NPN 24V XS106B3Nppp
2 wire, DC 24V XS606B3Cppp
M8, threaded short 3 wire, PNP 24V XS108B3Pppp
3 wire, NPN 24V XS108B3Nppp
2 wire, DC 24V XS608B3Cppp
M12, threaded short 3 wire, PNP 24V XS112B3Pppp
3 wire, NPN 24V XS112B3Nppp
2 wire, DC 24V XS612B3Dppp
M18, threaded short 3 wire, PNP 24V XS118B3Pppp
3 wire, NPN 24V XS118B3Nppp
2 wire, DC 24V XS618B3Dppp
M30, threaded short 3 wire, PNP 24V XS130B3Pppp
3 wire, NPN 24V XS130B3Nppp
2 wire, DC 24V XS630B3Dppp
Cylindrical,
ush, sensing
distance extending,
barel long
M8, threaded long 3 wire, PNP 24V-48V XS608B1Pppp
3 wire, NPN 24V-48V XS608B1Nppp
2 wire, DC 24V-48V XS608B1Dppp
M12, threaded long 3 wire, PNP 24V-48V XS612B1Pppp
3 wire, NPN 24V-48V XS612B1Nppp
2 wire, DC 24V-48V XS612B1Dppp
M18, threaded long 3 wire, PNP 24V-48V XS618B1Pppp
3 wire, NPN 24V-48V XS618B1Nppp
2 wire, DC 24V-48V XS618B1Dppp
M30, threaded long 3 wire, PNP 24V-48V XS630B1Pppp
3 wire, NPN 24V-48V XS630B1Nppp
2 wire, DC 24V-48V XS630B1Dppp
M12, threaded long 2 wire, AC/DC XS612B1Mppp
M18, threaded long 2 wire, AC/DC XS618B1Mppp
M30, threaded long 2 wire, AC/DC XS630B1Mppp
Cylindrical,
non ush, sensing
distance extending,
barel long
M12, threaded long 3 wire, PNP 24V-48V XS612B4Pppp
3 wire, NPN 24V-48V XS612B4Nppp
M18, threaded long 3 wire, PNP 24V-48V XS618B4Pppp
3 wire, NPN 24V-48V XS618B4Nppp
M30, threaded long 3 wire, PNP 24V-48V XS630B4Pppp
3 wire, NPN 24V-48V XS630B4Nppp
M12, threaded long 2 wire, AC/DC XS612B4Mppp
M18, threaded long 2 wire, AC/DC XS618B4Mppp
M30, threaded long 2 wire, AC/DC XS630B4Mppp
Compatible
Non compatible
1
2
3
4
5
6
7
8
9
10
7/11
Proximity sensors c Inputs, BMXDDI c Inputs, BMXDDM c Inputs, BMXAMI a Inputs, BMXDAI
Type Reference 1602 1603 1604T 3202K 6402K 16022 16025 3202K 0810 0800 1602 1603 1604 0805
General purpose
Cylindrical,
ush,
sensing distance
standard,
barel short
Ø 6,5 plain short 3 wire, PNP 24V XS506B1Pppp
3 wire, NPN 24V XS506B1Nppp
2 wire, DC 24V XS506BSCppp
M8, threaded short 3 wire, PNP 24V XS508B1Pppp
3 wire, NPN 24V XS508B1Nppp
2 wire, DC 24V XS508BSCppp
M12, threaded short 3 wire, PNP 24V XS512B1Pppp
3 wire, NPN 24V XS512B1Nppp
2 wire, DC 24V XS512BSD/Cppp
M18, threaded short 3 wire, PNP 24V XS518B1Pppp
3 wire, NPN 24V XS518B1Nppp
2 wire, DC 24V XS518BSD/Cppp
M30, threaded short 3 wire, PNP 24V XS530B1Pppp
3 wire, NPN 24V XS530B1Nppp
2 wire, DC 24V XS530BSD/Cppp
Cylindrical,
ush, sensing
distance standard,
barel long
M8, threaded long 3 wire, PNP 24V-48V XS508BLPppp
3 wire, NPN 24V-48V XS508BLNppp
2 wire, DC 24V-48V XS508B1D/Cppp
M12, threaded long 3 wire, PNP 24V-48V XS512BLPppp
3 wire, NPN 24V-48V XS512BLNppp
2 wire, DC 24V-48V XS512B1D/Cppp
M18, threaded long 3 wire, PNP 24V-48V XS518BLPppp
3 wire, NPN 24V-48V XS518BLNppp
2 wire, DC 24V-48V XS518B1D/Cppp
M30, threaded long 3 wire, PNP 24V-48V XS530BLPppp
3 wire, NPN 24V-48V XS530BLNppp
2 wire, DC 24V-48V XS530B1D/Cppp
M12, threaded long 2 wire, AC/DC XS512B1Mppp
M18, threaded long 2 wire, AC/DC XS518B1Mppp
M30, threaded long 2 wire, AC/DC XS530B1Mppp
Cylindrical,
ush, sensing
distance extending,
barel short
Ø 6,5 plain short 3 wire, PNP 24V XS106B3Pppp
3 wire, NPN 24V XS106B3Nppp
2 wire, DC 24V XS606B3Cppp
M8, threaded short 3 wire, PNP 24V XS108B3Pppp
3 wire, NPN 24V XS108B3Nppp
2 wire, DC 24V XS608B3Cppp
M12, threaded short 3 wire, PNP 24V XS112B3Pppp
3 wire, NPN 24V XS112B3Nppp
2 wire, DC 24V XS612B3Dppp
M18, threaded short 3 wire, PNP 24V XS118B3Pppp
3 wire, NPN 24V XS118B3Nppp
2 wire, DC 24V XS618B3Dppp
M30, threaded short 3 wire, PNP 24V XS130B3Pppp
3 wire, NPN 24V XS130B3Nppp
2 wire, DC 24V XS630B3Dppp
Cylindrical,
ush, sensing
distance extending,
barel long
M8, threaded long 3 wire, PNP 24V-48V XS608B1Pppp
3 wire, NPN 24V-48V XS608B1Nppp
2 wire, DC 24V-48V XS608B1Dppp
M12, threaded long 3 wire, PNP 24V-48V XS612B1Pppp
3 wire, NPN 24V-48V XS612B1Nppp
2 wire, DC 24V-48V XS612B1Dppp
M18, threaded long 3 wire, PNP 24V-48V XS618B1Pppp
3 wire, NPN 24V-48V XS618B1Nppp
2 wire, DC 24V-48V XS618B1Dppp
M30, threaded long 3 wire, PNP 24V-48V XS630B1Pppp
3 wire, NPN 24V-48V XS630B1Nppp
2 wire, DC 24V-48V XS630B1Dppp
M12, threaded long 2 wire, AC/DC XS612B1Mppp
M18, threaded long 2 wire, AC/DC XS618B1Mppp
M30, threaded long 2 wire, AC/DC XS630B1Mppp
Cylindrical,
non ush, sensing
distance extending,
barel long
M12, threaded long 3 wire, PNP 24V-48V XS612B4Pppp
3 wire, NPN 24V-48V XS612B4Nppp
M18, threaded long 3 wire, PNP 24V-48V XS618B4Pppp
3 wire, NPN 24V-48V XS618B4Nppp
M30, threaded long 3 wire, PNP 24V-48V XS630B4Pppp
3 wire, NPN 24V-48V XS630B4Nppp
M12, threaded long 2 wire, AC/DC XS612B4Mppp
M18, threaded long 2 wire, AC/DC XS618B4Mppp
M30, threaded long 2 wire, AC/DC XS630B4Mppp
Compatible
Non compatible
1
2
3
4
5
6
7
8
9
10
7/12
Compatibility Modicon M340
automation platform
Inputs and OsiSense XS inductive proximity
sensors
Proximity sensors c Inputs, BMXDDI c Inputs, BMXDDM c Inputs, BMXAMI a Inputs, BMXDAI
Type Reference 1602 1603 1604T 3202K 6402K 16022 16025 3202K 0810 0800 1602 1603 1604 0805
General purpose
Flat, ush montable,
sensing distance
standard
Format J 8x22x8 3 wire, PNP 24V XS7J1A1Pppp
3 wire, NPN 24V XS7J1A1Nppp
2 wire, DC 24V XS7J1A1Dppp
Format F 15x22x8 3 wire, PNP 24V XS7F1A1Pppp
3 wire, NPN 24V XS7F1A1Nppp
2 wire, DC 24V XS7F1A1Dppp
Format E 26x26x13 3 wire, PNP 24V XS7E1A1Pppp
3 wire, NPN 24V XS7E1A1Nppp
2 wire, DC 24V XS7E1A1D/Cppp
Format C 40x40x15 3 wire, PNP 24V XS7C1A1Pppp
3 wire, NPN 24V XS7C1A1Nppp
2 wire, DC 24V XS7C1A1D/Cppp
Format D 80x80x26 3 wire, PNP 24V XS7D1A1Pppp
3 wire, NPN 24V XS7D1A1Nppp
2 wire, DC 24V XS7D1A1D/Cppp
Format 40X40X117
Plastic, with turret
head: 5 positions
NO + NC 4 wire, PNP 24V-48V XS7/XS8C40PC44p
4 wire, NPN 24V-48V XS7/XS8C40NC44p
NO/NC programable 2 wire, DC 24V-48V XS7/XS8C40Dppppp
2 wire, AC XS7/XS8C40Fppppp
2 wire, AC/DC XS7/XS8C40Mppppp
Flat, ush montable,
sensing distance
extending
Format E 26x26x13 3 wire, PNP 24V XS8E1A1Pppp
3 wire, NPN 24V XS8E1A1Nppp
2 wire, AC/DC XS8E1A1Mppp
Format C 40x40x15 3 wire, PNP 24V XS8C1A1Pppp
3 wire, NPN 24V XS8C1A1Nppp
2 wire, AC/DC XS8C1A1Mppp
Format D 80x80x26 3 wire, PNP 24V XS8D1A1Pppp
3 wire, NPN 24V XS8D1A1Nppp
2 wire, AC/DC XS8D1A1Mppp
Cylindrical multi
tension
M12, threaded 2 wire, AC/DC XS1/2M12Mp250
M18, threaded 2 wire, AC/DC XS1/2M18Mp250
M30, threaded 2 wire, AC/DC XS1/2M30Mp250
Cylindrical Metal, 4
wire
Ø 6,5, plain 4 wire, PNP 24V XS1L06PC410
4 wire, NPN 24V XS1L06NC410
M8, threaded 4 wire, PNP 24V XS1/2M08PC410p
4 wire, NPN 24V XS1/2M08NC410p
M12, threaded 4 wire, PNP 24V XS1/2N12PC410p
4 wire, NPN 24V XS1/2N12NC410p
M18, threaded 4 wire, PNP 24V XS1/2N18PC410p
4 wire, NPN 24V XS1/2N18NC410p
M30, threaded 4 wire, PNP 24V XS1/2N30PC410p
4 wire, NPN 24V XS1/2N30NC410p
Cylindrical Metal,
4 wire PNP + NPN
M12, threaded 4 wire, PNP+NPN, prog. 24V XS1/2/4M12KP340p
M18, threaded 4 wire, PNP+NPN, prog. 24V XS1/2/4M18KP340p
M30, threaded 4 wire, PNP+NPN, prog. 24V XS1/2/4M30KP340p
Cylindrical Plastic,
non ush,
sensing distance
standard
M8, threaded 3 wire, PNP 24V XS4P08Pp340p
3 wire, PNP 24V-48V XS4P08Pp370p
3 wire, NPN 24V XS4P08Np340p
3 wire, NPN 24V-48V XS4P08Np370p
2 wire, AC/DC XS4P08Mp230ppp
M12, threaded 3 wire, PNP 24V XS4P12Pp340p
3 wire, PNP 24V-48V XS4P12Pp370p
3 wire, NPN 24V XS4P12Np340p
3 wire, NPN 24V-48V XS4P12Np370p
2 wire, AC/DC XS4P12Mp230ppp
M18, threaded 3 wire, PNP 24V XS4P18Pp340p
3 wire, PNP 24V-48V XS4P18Pp370p
3 wire, NPN 24V XS4P18Np340p
3 wire, NPN 24V-48V XS4P18Np370p
2 wire, AC/DC XS4P18Mp230ppp
M30, threaded 3 wire, PNP 24V XS4P30Pp340p
3 wire, PNP 24V-48V XS4P30Pp370p
3 wire, NPN 24V XS4P30Np340p
3 wire, NPN 24V-48V XS4P30Np370p
2 wire, AC/DC XS4P30Mp230ppp
Compatible
Non compatible
1
2
3
4
5
6
7
8
9
10
7/13
Proximity sensors c Inputs, BMXDDI c Inputs, BMXDDM c Inputs, BMXAMI a Inputs, BMXDAI
Type Reference 1602 1603 1604T 3202K 6402K 16022 16025 3202K 0810 0800 1602 1603 1604 0805
General purpose
Flat, ush montable,
sensing distance
standard
Format J 8x22x8 3 wire, PNP 24V XS7J1A1Pppp
3 wire, NPN 24V XS7J1A1Nppp
2 wire, DC 24V XS7J1A1Dppp
Format F 15x22x8 3 wire, PNP 24V XS7F1A1Pppp
3 wire, NPN 24V XS7F1A1Nppp
2 wire, DC 24V XS7F1A1Dppp
Format E 26x26x13 3 wire, PNP 24V XS7E1A1Pppp
3 wire, NPN 24V XS7E1A1Nppp
2 wire, DC 24V XS7E1A1D/Cppp
Format C 40x40x15 3 wire, PNP 24V XS7C1A1Pppp
3 wire, NPN 24V XS7C1A1Nppp
2 wire, DC 24V XS7C1A1D/Cppp
Format D 80x80x26 3 wire, PNP 24V XS7D1A1Pppp
3 wire, NPN 24V XS7D1A1Nppp
2 wire, DC 24V XS7D1A1D/Cppp
Format 40X40X117
Plastic, with turret
head: 5 positions
NO + NC 4 wire, PNP 24V-48V XS7/XS8C40PC44p
4 wire, NPN 24V-48V XS7/XS8C40NC44p
NO/NC programable 2 wire, DC 24V-48V XS7/XS8C40Dppppp
2 wire, AC XS7/XS8C40Fppppp
2 wire, AC/DC XS7/XS8C40Mppppp
Flat, ush montable,
sensing distance
extending
Format E 26x26x13 3 wire, PNP 24V XS8E1A1Pppp
3 wire, NPN 24V XS8E1A1Nppp
2 wire, AC/DC XS8E1A1Mppp
Format C 40x40x15 3 wire, PNP 24V XS8C1A1Pppp
3 wire, NPN 24V XS8C1A1Nppp
2 wire, AC/DC XS8C1A1Mppp
Format D 80x80x26 3 wire, PNP 24V XS8D1A1Pppp
3 wire, NPN 24V XS8D1A1Nppp
2 wire, AC/DC XS8D1A1Mppp
Cylindrical multi
tension
M12, threaded 2 wire, AC/DC XS1/2M12Mp250
M18, threaded 2 wire, AC/DC XS1/2M18Mp250
M30, threaded 2 wire, AC/DC XS1/2M30Mp250
Cylindrical Metal, 4
wire
Ø 6,5, plain 4 wire, PNP 24V XS1L06PC410
4 wire, NPN 24V XS1L06NC410
M8, threaded 4 wire, PNP 24V XS1/2M08PC410p
4 wire, NPN 24V XS1/2M08NC410p
M12, threaded 4 wire, PNP 24V XS1/2N12PC410p
4 wire, NPN 24V XS1/2N12NC410p
M18, threaded 4 wire, PNP 24V XS1/2N18PC410p
4 wire, NPN 24V XS1/2N18NC410p
M30, threaded 4 wire, PNP 24V XS1/2N30PC410p
4 wire, NPN 24V XS1/2N30NC410p
Cylindrical Metal,
4 wire PNP + NPN
M12, threaded 4 wire, PNP+NPN, prog. 24V XS1/2/4M12KP340p
M18, threaded 4 wire, PNP+NPN, prog. 24V XS1/2/4M18KP340p
M30, threaded 4 wire, PNP+NPN, prog. 24V XS1/2/4M30KP340p
Cylindrical Plastic,
non ush,
sensing distance
standard
M8, threaded 3 wire, PNP 24V XS4P08Pp340p
3 wire, PNP 24V-48V XS4P08Pp370p
3 wire, NPN 24V XS4P08Np340p
3 wire, NPN 24V-48V XS4P08Np370p
2 wire, AC/DC XS4P08Mp230ppp
M12, threaded 3 wire, PNP 24V XS4P12Pp340p
3 wire, PNP 24V-48V XS4P12Pp370p
3 wire, NPN 24V XS4P12Np340p
3 wire, NPN 24V-48V XS4P12Np370p
2 wire, AC/DC XS4P12Mp230ppp
M18, threaded 3 wire, PNP 24V XS4P18Pp340p
3 wire, PNP 24V-48V XS4P18Pp370p
3 wire, NPN 24V XS4P18Np340p
3 wire, NPN 24V-48V XS4P18Np370p
2 wire, AC/DC XS4P18Mp230ppp
M30, threaded 3 wire, PNP 24V XS4P30Pp340p
3 wire, PNP 24V-48V XS4P30Pp370p
3 wire, NPN 24V XS4P30Np340p
3 wire, NPN 24V-48V XS4P30Np370p
2 wire, AC/DC XS4P30Mp230ppp
Compatible
Non compatible
1
2
3
4
5
6
7
8
9
10
7/14
Compatibility Modicon M340
automation platform
Inputs and OsiSense XS inductive proximity
sensors
Proximity sensors c Inputs, BMXDDI c Inputs, BMXDDM c Inputs, BMXAMI a Inputs, BMXDAI
Type Reference 1602 1603 1604T 3202K 6402K 16022 16025 3202K 0810 0800 1602 1603 1604 0805
General purpose
Cylindrical basic
ush or non ush,
sensing distance
standard,
Plastic or Metal
Ø 6,5 plain 3 wire, PNP 24V XS1/206BLPppp
3 wire, NPN 24V XS1/206BLNppp
M8, threaded 3 wire, PNP 24V XS1/208A/BLPppp
3 wire, NPN 24V XS1/208A/BLNppp
M12, threaded 3 wire, PNP 24V XS1/212A/BLPppp
3 wire, NPN 24V XS1/212A/BLNppp
M18, threaded 3 wire, PNP 24V XS1/218A/BLPppp
3 wire, NPN 24V XS1/218A/BLNppp
M30, threaded 3 wire, PNP 24V XS1/230A/BLPppp
3 wire, NPN 24V XS1/230A/BLNppp
Cylindrical,
almost ush, sensing
distance extending
Ø 6,5 plain 3 wire, PNP 24V XS1L06Pp349p
3 wire, NPN 24V XS1L06Np349p
M8, threaded 3 wire, PNP 24V XS1N08Pp349p
3 wire, NPN 24V XS1N08Np349p
M12, threaded 3 wire, PNP 24V XS1N12Pp349p
3 wire, NPN 24V XS1N12Np349p
M18, threaded 3 wire, PNP 24V XS1N18Pp349p
3 wire, NPN 24V XS1N18Np349p
M30, threaded 3 wire, PNP 24V XS1N30Pp349p
3 wire, NPN 24V XS1N30Np349p
Cylindrical,
miniature
Ø 4 plain 3 wire, PNP 24V XS1L04Pp31pp
3 wire, NPN 24V XS1L04Np31pp
M5, threaded 3 wire, PNP 24V XS1N05Pp31pp
3 wire, NPN 24V XS1N05Np31pp
Ø 6,5 plain 3 wire, PNP 24V XS2L06Pp340p
3 wire, NPN 24V XS2L06Np340p
Application
Cylindrical,
adjustable sensing
distance,
M12, threaded 3 wire, PNP 24V XS612B2Pppp
3 wire, NPN 24V XS612B2Nppp
M18, threaded 3 wire, PNP 24V XS618B2Pppp
3 wire, NPN 24V XS618B2Nppp
M30, threaded 3 wire, PNP 24V XS630B2Pppp
3 wire, NPN 24V XS630B2Nppp
Rotation monitoring M18, threaded 3 wire, PNP 24V-48V XSAV11/2373
2 wire, AC/DC XSAV11/2801
Format E 26x26x13 3 wire, PNP 24V XS9p11RPpppp
Format C 40x40x15 2 wire, AC/DC XS9p11RMpppp
Analog output M12, threaded 2 wire 4 to 20mA; 3 wire 0 to 10V XSp12ABpppp
M18, threaded 2 wire 4 to 20mA; 3 wire 0 to 10V XSp18ABpppp
M30, threaded 2 wire 4 to 20mA; 3 wire 0 to 10V XSp30ABpppp
Block format 2 wire 4 to 20mA; 3 wire 0 to 10V XS9p111Apppp
Food and beverage Cylindrical threaded Metal 3 wire, PNP 24V XS2ppSAPppp
3 wire, NPN 24V XS2ppSANppp
2 wire, AC/DC XS2ppSAMAppp
Cylindrical threaded Plastic 3 wire, PNP 24V-48V XS2ppAAPppp
3 wire, NPN 24V XS2ppAANppp
2 wire, AC/DC XS2ppAAMAppp
Factor 1 Cylindrical threaded Metal 4 wire, PNP+NPN 24V XS1MppKPM40
Forme C, 40 x 117 x 41 4 wire, PNP+NPN 24V XS7C40KPM40
Cylindrical threaded Metal 3 wire, PNP 24V XS1M18PASpp
Packaging Format 12x26x40 3 wire, PNP 24V XS7G12Pp140
3 wire, NPN 24V XS7G12Np140
4 wire, PNP 24V-48V XS7G12Pp440
4 wire, NPN 24V-48V XS7G12Np440
2 wire, AC/DC XS7G12Mp230
Material handling Format C 40x40x40 2 wire, DC 24V-48V XS7T4DAppp
4 wire, PNP 24V-48V XS7T4PCppp
4 wire, NPN 24V-48V XS7T4NCppp
Format D 80x80x26 2 wire, DC 24V-48V XS7D1pppp
Welding Cylindrical Metal 3 wire, PNP 24V XS1MppPAWpp
2 wire, DC 24V-48V XSLCppp
Compatible
Non compatible
1
2
3
4
5
6
7
8
9
10
7/15
Proximity sensors c Inputs, BMXDDI c Inputs, BMXDDM c Inputs, BMXAMI a Inputs, BMXDAI
Type Reference 1602 1603 1604T 3202K 6402K 16022 16025 3202K 0810 0800 1602 1603 1604 0805
General purpose
Cylindrical basic
ush or non ush,
sensing distance
standard,
Plastic or Metal
Ø 6,5 plain 3 wire, PNP 24V XS1/206BLPppp
3 wire, NPN 24V XS1/206BLNppp
M8, threaded 3 wire, PNP 24V XS1/208A/BLPppp
3 wire, NPN 24V XS1/208A/BLNppp
M12, threaded 3 wire, PNP 24V XS1/212A/BLPppp
3 wire, NPN 24V XS1/212A/BLNppp
M18, threaded 3 wire, PNP 24V XS1/218A/BLPppp
3 wire, NPN 24V XS1/218A/BLNppp
M30, threaded 3 wire, PNP 24V XS1/230A/BLPppp
3 wire, NPN 24V XS1/230A/BLNppp
Cylindrical,
almost ush, sensing
distance extending
Ø 6,5 plain 3 wire, PNP 24V XS1L06Pp349p
3 wire, NPN 24V XS1L06Np349p
M8, threaded 3 wire, PNP 24V XS1N08Pp349p
3 wire, NPN 24V XS1N08Np349p
M12, threaded 3 wire, PNP 24V XS1N12Pp349p
3 wire, NPN 24V XS1N12Np349p
M18, threaded 3 wire, PNP 24V XS1N18Pp349p
3 wire, NPN 24V XS1N18Np349p
M30, threaded 3 wire, PNP 24V XS1N30Pp349p
3 wire, NPN 24V XS1N30Np349p
Cylindrical,
miniature
Ø 4 plain 3 wire, PNP 24V XS1L04Pp31pp
3 wire, NPN 24V XS1L04Np31pp
M5, threaded 3 wire, PNP 24V XS1N05Pp31pp
3 wire, NPN 24V XS1N05Np31pp
Ø 6,5 plain 3 wire, PNP 24V XS2L06Pp340p
3 wire, NPN 24V XS2L06Np340p
Application
Cylindrical,
adjustable sensing
distance,
M12, threaded 3 wire, PNP 24V XS612B2Pppp
3 wire, NPN 24V XS612B2Nppp
M18, threaded 3 wire, PNP 24V XS618B2Pppp
3 wire, NPN 24V XS618B2Nppp
M30, threaded 3 wire, PNP 24V XS630B2Pppp
3 wire, NPN 24V XS630B2Nppp
Rotation monitoring M18, threaded 3 wire, PNP 24V-48V XSAV11/2373
2 wire, AC/DC XSAV11/2801
Format E 26x26x13 3 wire, PNP 24V XS9p11RPpppp
Format C 40x40x15 2 wire, AC/DC XS9p11RMpppp
Analog output M12, threaded 2 wire 4 to 20mA; 3 wire 0 to 10V XSp12ABpppp
M18, threaded 2 wire 4 to 20mA; 3 wire 0 to 10V XSp18ABpppp
M30, threaded 2 wire 4 to 20mA; 3 wire 0 to 10V XSp30ABpppp
Block format 2 wire 4 to 20mA; 3 wire 0 to 10V XS9p111Apppp
Food and beverage Cylindrical threaded Metal 3 wire, PNP 24V XS2ppSAPppp
3 wire, NPN 24V XS2ppSANppp
2 wire, AC/DC XS2ppSAMAppp
Cylindrical threaded Plastic 3 wire, PNP 24V-48V XS2ppAAPppp
3 wire, NPN 24V XS2ppAANppp
2 wire, AC/DC XS2ppAAMAppp
Factor 1 Cylindrical threaded Metal 4 wire, PNP+NPN 24V XS1MppKPM40
Forme C, 40 x 117 x 41 4 wire, PNP+NPN 24V XS7C40KPM40
Cylindrical threaded Metal 3 wire, PNP 24V XS1M18PASpp
Packaging Format 12x26x40 3 wire, PNP 24V XS7G12Pp140
3 wire, NPN 24V XS7G12Np140
4 wire, PNP 24V-48V XS7G12Pp440
4 wire, NPN 24V-48V XS7G12Np440
2 wire, AC/DC XS7G12Mp230
Material handling Format C 40x40x40 2 wire, DC 24V-48V XS7T4DAppp
4 wire, PNP 24V-48V XS7T4PCppp
4 wire, NPN 24V-48V XS7T4NCppp
Format D 80x80x26 2 wire, DC 24V-48V XS7D1pppp
Welding Cylindrical Metal 3 wire, PNP 24V XS1MppPAWpp
2 wire, DC 24V-48V XSLCppp
Compatible
Non compatible
1
2
3
4
5
6
7
8
9
10
7/16
Modicon M340
automation platform
Power consumption table
Choice of BMXCPSppppp
power supplies
Introduction
The power required to supply each BMXXBPpp00 rack depends on the type and
number of modules installed in the racks. It is therefore necessary to draw up a
power consumption table rack-by-rack to determine the BMXCPSppppp power
supply module that best ts each rack.
The calculation sheet on the page opposite can be used to calculate the power
consumption of the 2 or 3 voltages provided (depending on the model) by the
BMXCPSppppp power supply module: 3.3 V c, 24 V c (rack) and 24 V c (sensors).
Method
Check and select a power supply module corresponding to the power available on
b
the 2 or 3 voltages.
Check that the sum of the absorbed power on these three voltages does not
b
exceed the maximum power of the power supply module.
b Values to be entered depending on the Modicon M340 PAC
conguration.
1
2
3
4
5
6
7
8
9
10
7/17
Modicon M340
automation platform
Power consumption table
Calculation sheet
Choice of BMXCPSppppp
power supplies
Module reference Format Number Consumption in mA (1)
Rack no.
0 - 1 - 2 - 3
S: Standard
D: Double
3.3 V c
voltage
24 V c
rack voltage
24 V c
sensor voltage
Module Total Module Total Module Total
Processor
(rack 0)
BMXP341000(H) S 72
BMXP342000 S 72
BMXP342010/20102 S 90
BMXP342020(H) S 95
BMXP342030/20302(H) S 135
Rack expansion
(rack 0, 1, 2 or 3)
BMXXBE1000 22 160
Discrete I/O
BMXDAI0805
S 76 13
BMXDAI1602
(H) S 90 60
BMXDAI1603
(H) S 90 60
BMXDAI1604
(H) S 90 60
BMXDAO1605
(H) S 100 95
BMXDDI1602
(H) S 90
BMXDDI1603
(H) S 90
BMXDDI1604T
S 76
BMXDDI3202K
S 140 110
BMXDDI6402K
S 200 110
BMXDDM16022
(H) S 100 30
BMXDDM16025
(H) S 100 50 30
BMXDDM3202K
S 150 55
BMXDDO1602
(H) S 100
BMXDDO1612
(H) S 100
BMXDDO3202K
S 150
BMXDDO6402K
S 240
BMXDRA0804T
S 61 104
BMXDRA0805
(H) S 100 55
BMXDRA1605
(H) S 100 95
Analog I/O
BMXAMI0410
(H) S 150 45
BMXAMI0800
S 150 30
BMXAMI0810
S 150 45
BMXAMM0600
(H) S 150 130
BMXAMO0210
(H) S 150 110
BMXAMO0410
S 150 84
BMXAMO0802
S 150 74
BMXART0414
(H) S 150 40
BMXART0814
(H) S 150 100
Counting
BMXEHC0200
(H) S 200 40 80
BMXEHC0800
(H) S 200 80
Motion control
BMXMSP0200
S 200 150
Communication
BMXEIA0100
S 160
BMXNOE0100
(H) S 90
BMXNOE0110
(H) S 90
BMXNOM0200
(H) S 80
BMXNOC0401
S 555
BMXNOR0200(H)
S 95
Power consumption Total current (mA)
x 3.3 V x 24 V x 24 V
Power consumed
(mW)
+ + =
Available power (mW) Total power (mW)
Choice of power
supply module
BMXCPS2010
D 24 V c isolated 8250 16,800 17,000
BMXCPS3020
(H) D 24 to 48 V c isolated 14,850 31,200 32,000
BMXCPS2000
D 100 to 240 V a8250 16,800 10,800 20,000
BMXCPS3500
(H) D14,850 31,200 21,600 36,000
BMXCPS3540T
D 125 V c14,850 31,200 21,600 36,000
(1) Typical value given for 100% of inputs or outputs at state 1.
yyyy
Photocopy this document or use the
M340 Design software, available on our website:
www.schneider-electric.com
1
2
3
4
5
6
7
8
9
10
7/18
Modicon M340
automation platform
Dedicated services offer for your installed base
Operation services
Introduction
Our competent and efcient experts can provide effective maintenance, upgrading
and modernization of your facilities.
Our services offer is structured around two phases of your installation life cycle:
Operation: b
Spare parts and repairs
v
Maintenance contracts
v
Training
v
Modernization: b
Consultancy and expertise
v
Project management
v
Customization services are also available to accommodate your specic
requirements.
Operation services
Spare parts and repairs Everything you need to get your equipment back to work as quickly as possible
We are able to respond very quickly to requests for spare parts, exchanges and
repairs to your installed automation equipment (automation platforms, Human
Machine Interfaces, drives, distributed I/O) with:
Supply of tested, certied and compatible spare parts b
Repaired parts will be of the same quality as new products b
Availability of our teams to respond to your requests 24/7 b
Standard replacements or fast exchange service for certain parts with the option b
to receive the replacement product the next business day
Maintenance contracts Improving the long-term reliability and performance of your installations
We provide a contract solution to full your logistical, technical, human and nancial
requirements. This solution is based around the following services:
Hotline with priority access to our group of experts b
Software via the Internet with access to the latest upgrades of the current software b
Spare parts stock b - a Schneider Electric owned stock of spare parts on your site or
in one of our warehouses
On-site assistance with agreed upon servicing time b(1)
Extended warranty offering up to 5 years manufacturer warranty on installed b
equipment ranges on your site (1)
Maintenance & Modernization Consultancy providing analysis of existing systems b
and proposal of a detailed improvement plan (1)
Modernization - a complete process to update your legacy systems based upon b
your specic requirements (1)
(1) Also available as a stand alone offer. Please consult our Customer Care Center.
Training Dedicated training plans to allow you to acquire the necessary competencies to
optimize productivity of your installed base
We are committed to providing your teams with the necessary competencies to
operate more effectively, make the operations more secure and optimize the
efciency of your installed equipment:
Identication of your needs by systematic analysis of the competency and b
functions of your teams
Proposal of a set of training modules covering your entire installed automation b
equipment base
Preparation of customized modules to suit your needs (content, schedule, etc.). b
Note: To check availability of services required, please contact our Customer Care Center.
Project
management
Operation
Modernization
Spare parts
and repairs
Consultancy
and expertise
Training
Maintenance
contracts
1
2
3
4
5
6
7
8
9
10
7/19
Introduction (continued) Modicon M340
automation platform
Dedicated services offer for your installed base
Modernization services
Customization services
Modernization services
Consultancy and expertise Proven expertise, tools and methods to give you a clear vision of the improvement
opportunities and guide you toward a successful modernization project
With our M2C (Maintenance & Modernization
Consultancy) offer, we help you check the state of your
installed base by:
Dening the scope and depth of the analysis in b
collaboration with you
Collecting the technical data without shutting down b
production
Analyzing and identifying avenues for improvement b
Producing a recommendation b
Customer benets:
Reduction in the impact of of lost system availability b
Improved system availability b
Improved performance b
The M2C (Maintenance & Modernization Consultancy) offer
Our experts will analyze your existing systems, propose an action plan and deploy
the appropriate solutions.
Process consultancy b
Based on audit implementation dedicated to your application, our consultants will
help you assess opportunities, dene various solutions, estimate budgets and draw
up a deployment plan.
Installed base consultancy b
For preventive maintenance operations or in case of detected failures or detected
malfunctions, our tools and methods can be used for diagnosis and control of critical
automation functions, such as communication networks, high-power drives and
process control automation.
A detailed report with comments is submitted as part of our service.
Project management Professional tools, methods and a proven experience in project management to
help reduce risks and improve performance.
Our services are provided by experienced project managers who have a precise
knowledge of the evolution of our equipment and use efcient tools and methods
with proven effectiveness to:
Limit production down time by using our conversion and software/hardware b
migration solutions
Improve performance of existing tools by: b
Analyzing the performance levels to be achieved and designing, validating and
v
implementing the new architecture
Updating your application following modernization of your equipment
v
Provide long-term support by helping to ensure: b
The design and deployment of a standardized solution for projects spanning
v
several production sites
A contractual approach that provides a change from the usual investment process,
v
combining maintenance of existing facilities and scheduled modernization
Training of maintenance teams on the operation of the new system
v
Wide range of migration offers
Solution Change the
CPU
Keep the I/O
racks &
wiring
Change the
I/O racks &
keep the
wiring
Migrate your
application
Manage your
project
Execute your
project
Platform (1) TSX47 to TSX107
April series 1000
Modicon p84, compact
April SMC
Merlin Gerin PB
AEG
Symax
Service available
(1) Our migration service offer also includes SCADA, Human Machine Interfaces, drives,
communication networks and distributed I/O.
Customization services
We are able to meet your specic requirements and provide you with adapted
products:
Protective coating for Human Machine Interfaces, automation platforms and b
distributed I/O modules for use in harsh environments
Customized cable lengths to match your specic needs b
Customized front panels for Human Machine Interfaces b
Note: To check availability of services required, please contact our Customer Care Center.
1
2
3
4
5
6
7
8
9
10
7/20
Index Product reference index
1
110XCA28201 4/23
110XCA28202 4/23
110XCA28203 4/23
4
490NOC00005 3/41
490NOR00003 3/41
490NOR00005 3/41
490NOT00005 3/41
490NTC00005 3/40
490NTC00005U 3/40
490NTC00015 3/40
490NTC00040 3/40
490NTC00040U 3/40
490NTC00080 3/40
490NTC00080U 3/40
490NTW00002 3/40
490NTW00002U 3/40
490NTW00005 3/40
490NTW00005U 3/40
490NTW00012 3/40
490NTW00012U 3/40
490NTW00040 3/40
490NTW00040U 3/40
490NTW00080 3/40
490NTW00080U 3/40
499NEH10410 3/42
499NES18100 3/43
499NMS25101 3/44
499NMS25102 3/44
499NSS25101 3/44
499NSS25102 3/44
9
990NAA26320 4/23
990NAA26350 4/23
A
ABE7ACC01 5/19
ABE7ACC02 5/19
ABE7ACC10 5/19
ABE7ACC11 5/19
ABE7ACC12 5/17
ABE7ACC20 5/19
ABE7ACC21 5/19
ABE7ACC82 5/19
ABE7ACC84 5/19
ABE7ACC85 5/19
ABE7BV10 5/19
ABE7BV20 5/19
ABE7CPA01 5/18
ABE7CPA02 2/23
5/18
ABE7CPA03 2/23
5/18
ABE7CPA11 5/18
ABE7CPA12 5/18
ABE7CPA13 5/18
ABE7CPA21 2/23
5/18
ABE7CPA31 2/23
5/18
ABE7CPA31E 2/23
5/18
ABE7CPA410 2/23
5/18
6/7
ABE7CPA412 2/23
5/18
6/7
ABE7FU012 5/19
ABE7FU050 5/19
ABE7FU100 5/19
ABE7FU200 5/19
ABE7FU400 5/19
ABE7FU630 5/19
ABE7H08R10 5/13
ABE7H08R11 5/13
ABE7H08R21 5/13
ABE7H08S21 5/13
ABE7H12R10 5/13
ABE7H12R11 5/13
ABE7H12R20 5/13
ABE7H12R21 5/13
ABE7H12R50 5/13
ABE7H12S21 5/13
ABE7H16C10 5/12
ABE7H16C11 5/12
ABE7H16C21 5/12
ABE7H16C31 5/12
ABE7H16CM11 5/12
ABE7H16CM21 5/12
ABE7H16F43 5/13
ABE7H16R10 5/13
ABE7H16R11 5/13
ABE7H16R20 5/13
ABE7H16R21 5/13
ABE7H16R23 5/13
ABE7H16R30 5/13
ABE7H16R31 5/13
ABE7H16R50 5/13
ABE7H16S21 5/13
ABE7H16S43 5/13
ABE7H20E100 5/12
ABE7H20E200 5/12
ABE7H20E300 5/12
ABE7H32E150 5/12
ABE7H32E300 5/12
ABE7H34E000 5/12
ABE7H34E100 5/12
ABE7H34E200 5/12
ABE7H34E300 5/12
ABE7P08T330 5/16
ABE7P16F310 5/15
ABE7P16F312 5/15
ABE7P16T111 5/16
ABE7P16T210 5/16
ABE7P16T212 5/16
ABE7P16T214 5/16
ABE7P16T215 5/16
ABE7P16T230 5/16
ABE7P16T318 5/16
ABE7P16T330 5/16
ABE7P16T332 5/16
ABE7P16T334 5/16
ABE7R08S111 5/14
ABE7R08S210 5/14
ABE7R08S216 5/14
ABE7R16M111 5/15
ABE7R16S111 5/14
ABE7R16S111E 5/14
ABE7R16S210 5/14
ABE7R16S210E 5/14
ABE7R16S212 5/14
ABE7R16T111 5/15
ABE7R16T210 5/15
ABE7R16T212 5/15
ABE7R16T230 5/15
ABE7R16T231 5/15
ABE7R16T330 5/15
ABE7R16T332 5/15
ABE7R16T370 5/15
ABE7S16E2B1 5/14
ABE7S16E2B1E 5/14
ABE7S16E2E0 5/14
ABE7S16E2E1 5/14
ABE7S16E2F0 5/14
ABE7S16E2M0 5/14
ABE7S16E2M0E 5/14
ABE7S16S1B2 5/14
ABE7S16S1B2E 5/14
ABE7S16S2B0 5/14
ABE7S16S2B0E 5/14
ABE7TES160 5/19
ABFC08R02B 5/19
ABFC08R02R 5/19
ABFC08R02W 5/19
ABFC08R12B 5/19
ABFC08R12R 5/19
ABFC08R12W 5/19
ABL1A02 5/25
5/29
ABL4RSM24035 5/29
ABL4RSM24050 5/29
ABL4RSM24100 5/29
ABL4RSM24200 5/29
ABL4WSR24200 5/29
ABL4WSR24300 5/29
ABL4WSR24400 5/29
ABL8BBU24200 5/25
5/29
ABL8BBU24400 5/25
5/29
ABL8BPK24A03 5/25
5/29
ABL8BPK24A07 5/25
5/29
ABL8BPK24A12 5/25
5/29
ABL8BUF24400 5/25
5/29
ABL8DCC05060 5/25
5/29
ABL8DCC12020 5/25
5/29
ABL8FUS01 5/25
5/29
ABL8FUS02 5/25
5/29
ABL8PRP24100 5/25
5/29
ABL8RED24400 5/25
5/29
ABL8RPM24200 5/25
ABL8RPS24030 5/25
ABL8RPS24050 5/25
ABL8RPS24100 5/25
ABL8WPS24200 5/25
ABL8WPS24400 5/25
ABR7S11 5/17
ABR7S21 5/17
ABR7S23 5/17
ABR7S33 5/17
ABR7S33E 5/17
ABR7S37 5/17
ABS7EA3E5 5/17
ABS7EA3F5 5/17
ABS7EA3M5 5/17
ABS7EC3AL 5/17
ABS7EC3B2 5/17
ABS7SA2M 5/17
ABS7SA3MA 5/17
ABS7SC1B 5/17
ABS7SC2E 5/17
ABS7SC3BA 5/17
ABS7SC3E 5/17
AR1SB3 5/19
ASI20MACC5 5/25
5/29
ASITERV2 3/71
B
BMXAMI0410 2/22
BMXAMI0410H 6/7
BMXAMI0800 2/22
BMXAMI0810 2/22
BMXAMM0600 2/22
BMXAMM0600H 6/7
BMXAMO0210 2/22
BMXAMO0210H 6/7
BMXAMO0410 2/22
BMXAMO0802 2/22
BMXART0414 2/22
BMXART0414H 6/7
BMXART0814 2/22
BMXART0814H 6/7
BMXCPS2000 1/9
BMXCPS2010 1/9
BMXCPS3020 1/9
BMXCPS3020H 6/4
BMXCPS3500 1/9
BMXCPS3500H 6/4
BMXCPS3540T 1/9
BMXDAI0805 2/12
BMXDAI1602 2/12
BMXDAI1602H 6/6
BMXDAI1603 2/12
BMXDAI1603H 6/6
BMXDAI1604 2/12
BMXDAI1604H 6/6
BMXDAO1605 2/12
BMXDAO1605H 6/6
BMXDDI1602 2/12
BMXDDI1602H 6/6
BMXDDI1603 2/12
BMXDDI1603H 6/6
BMXDDI1604T 2/12
BMXDDI3202K 2/12
BMXDDI6402K 2/12
BMXDDM16022 2/13
BMXDDM16022H 6/6
BMXDDM16025 2/13
BMXDDM16025H 6/6
BMXDDM3202K 2/13
BMXDDO1602 2/12
BMXDDO1602H 6/6
BMXDDO1612 2/12
BMXDDO1612H 6/6
BMXDDO3202K 2/12
BMXDDO6402K 2/12
BMXDRA0804T 2/12
BMXDRA0805 2/12
BMXDRA0805H 6/6
BMXDRA1605 2/12
BMXDRA1605H 6/6
BMXEHC0200 2/31
BMXEHC0200H 6/9
BMXEHC0800 2/31
BMXEHC0800H 6/9
BMXEIA0100 3/71
BMXFCA150 2/23
6/7
BMXFCA152 2/23
6/7
BMXFCA300 2/23
6/7
BMXFCA302 2/23
6/7
BMXFCA500 2/23
6/7
BMXFCA502 2/23
6/7
BMXFCC051 2/13
BMXFCC053 2/13
BMXFCC101 2/13
BMXFCC103 2/13
BMXFCC201 2/13
BMXFCC203 2/13
BMXFCC301 2/13
BMXFCC303 2/13
BMXFCC501 2/13
BMXFCC503 2/13
BMXFCC1001 2/13
BMXFCC1003 2/13
BMXFCW301 2/13
BMXFCW301S 2/23
6/7
BMXFCW303 2/13
BMXFCW501 2/13
BMXFCW501S 2/23
6/7
BMXFCW503 2/13
BMXFCW1001 2/13
BMXFCW1003 2/13
BMXFTA150 2/23
BMXFTA152 2/23
1
2
3
4
5
6
7
8
9
10
7/21
BMXFTA300 2/23
BMXFTA302 2/23
BMXFTB2000
2/13
2/23
2/31
6/6
6/7
6/9
BMXFTB2010 6/6
6/7
BMXFTB2020 2/31
6/6
6/7
6/9
BMXFTB2820 2/23
2/33
BMXFTW301 2/13
6/6
BMXFTW301S 2/23
6/7
BMXFTW308S 2/23
BMXFTW501 2/13
6/6
BMXFTW501S 2/23
6/7
BMXFTW508S 2/23
BMXFTW1001 2/13
6/6
BMXMSP0200 2/33
BMXNOC0401 3/21
BMXNOE0100 3/19
BMXNOE0100H 6/8
BMXNOE0110 3/19
BMXNOE0110H 6/8
BMXNOM0200 3/75
BMXNOM0200H 6/8
BMXNOR0200H 3/25
6/8
BMXP341000 1/7
3/75
BMXP341000H 6/3
BMXP342000 1/7
3/75
BMXP342010 3/75
BMXP3420102 1/7
3/66
3/75
BMXP342020 1/7
3/18
3/75
BMXP342020H 6/3
BMXP3420302 1/7
3/18
3/66
BMXP3420302H 6/3
BMXRMS008MP 1/7
6/3
BMXRMS008MPF 1/7
6/3
BMXRMS128MPF 1/7
6/3
BMXRWS128MWF 3/25
BMXRWSB000M 3/19
BMXRWSFC032M 3/19
BMXXBC008K 1/13
6/5
BMXXBC015K 1/13
6/5
BMXXBC030K 1/13
6/5
BMXXBC050K 1/13
6/5
BMXXBC120K 1/13
6/5
BMXXBE1000 1/13
BMXXBE1000H 6/5
BMXXBE2005 1/13
BMXXBP0400 1/11
BMXXBP0400H 6/5
BMXXBP0600 1/11
BMXXBP0600H 6/5
BMXXBP0800 1/11
BMXXBP0800H 6/5
BMXXBP1200 1/11
BMXXCAUSBH018 1/7
4/23
6/3
BMXXCAUSBH045 1/7
4/23
6/3
BMXXEM010 1/11
6/5
BMXXSP0400 1/11
6/5
BMXXSP0600 1/11
6/5
BMXXSP0800 1/11
6/5
BMXXSP1200 1/11
BMXXTSCPS10 1/9
6/4
BMXXTSCPS20 1/9
6/4
BMXXTSHSC20 2/31
6/9
E
EUSENG1CFTAL10 4/46
EUSENG3CFTAL10 4/46
EUSENG2CFTV11 4/33
EUSENG2CFUV11 4/33
F
FTXBLA10 3/69
FTXC78B 3/69
FTXC78F5 3/69
FTXC78M5 3/69
FTXCM08B 3/69
FTXCM12B 3/69
FTXCN12F5 3/68
FTXCN12M5 3/68
FTXCN3203 3/68
FTXCN3206 3/68
FTXCN3210 3/68
FTXCN3220 3/68
FTXCN3230 3/68
FTXCN3250 3/68
FTXCNCT1 3/69
FTXCNTL12 3/69
FTXCY1208 3/69
FTXCY1212 3/69
FTXDG12 3/69
FTXDP2115 3/69
FTXDP2130 3/69
FTXDP2150 3/69
FTXDP2206 3/69
FTXDP2210 3/69
FTXDP2220 3/69
FTXDP2250 3/69
FTXMLA10 3/69
L
LAD90 5/25
5/29
LU9GC3 3/76
S
SR2CBL06 4/23
SR2MEM02 5/25
5/29
STBXCA4002 4/23
STBXSP3010 1/11
6/5
STBXSP3020 1/11
6/5
T
TCSCCN4F3M05T 3/68
TCSCCN4F3M1T 3/68
TCSCCN4F3M3T 3/68
TCSCTN011M11F 3/69
TCSEAAF11F13F00 3/41
TCSEAAF1LFH00 3/41
TCSEAAF1LFS00 3/41
TCSEAAF1LFU00 3/41
TCSEAM0100 3/41
TCSECL1M1M1S2 3/41
TCSECL1M1M3S2 3/41
TCSECL1M1M10S2 3/41
TCSECL1M1M25S2 3/41
TCSECL1M1M40S2 3/41
TCSECL1M3M1S2 3/41
TCSECL1M3M3S2 3/41
TCSECL1M3M10S2 3/41
TCSECL1M3M25S2 3/41
TCSECL1M3M40S2 3/41
TCSECN300R2 3/40
TCSEK1MDRS 3/40
TCSEK3MDS 3/40
TCSEGPA23F14FK 6/8
TCSESM043F1CU0 3/45
TCSESM043F23F0 3/45
TCSESM043F2CU0 3/45
TCSESM063F2CS1 3/46
TCSESM063F2CU1 3/46
TCSESM083F1CS0 3/46
TCSESM083F1CU0 3/46
TCSESM083F23F0 3/45
TCSESM083F23F1 3/46
TCSESM083F2CS0 3/46
TCSESM083F2CU0 3/46
TCSESM103F23G0 3/47
TCSESM103F2LG0 3/47
TCSESM163F23F0 3/47
TCSESM163F2CU0 3/47
TCSESM243F2CU0 3/47
TCSESU033FN0 3/44
TCSESU043F1CS0 3/45
TCSESU043F1N0 3/44
TCSESU043F2CS0 3/45
TCSESU051F0 3/43
TCSESU053FN0 3/44
TCSESU083FN0 3/43
TCSMCN3M4F3C2 3/75
3/77
TCSMCN3M4M3S2 3/75
3/77
6/8
TCSXCN3M4F3S4 3/75
6/8
TCSWAAC 3/59
TCSWAB2D 3/59
TCSWAB2O 3/58
TCSWAB2S 3/59
TCSWAB5D 3/58
TCSWAB5DN 3/58
TCSWAB5O 3/58
TCSWAB5S 3/58
TCSWAB5V 3/58
TCSWAB5VN 3/58
TCSWABAC2 3/59
TCSWABAC15 3/59
TCSWABC5 3/59
TCSWABC10 3/59
TCSWABDON 3/58
TCSWABMK 3/59
TCSWABP 3/59
TCSWABP68 3/59
TCSWAMC67 3/59
TCSWAMCD 3/59
TCSGWA242 3/58
TCSGWA242F 3/58
TCSGWA272 3/58
TCSGWABDH 3/58
TCSGWC241 3/58
TCSNWA241 3/58
TCSNWA241F 3/58
TCSNWA271 3/58
TCSNWA271F 3/58
TCSNWA2A1 3/58
TLACDCBA005 3/68
TLACDCBA015 3/68
TLACDCBA030 3/68
TLACDCBA050 3/68
TLXCDLFOFS33 4/57
TLXCDLUOFS33 4/57
TLXCDLTOFS33 4/57
TLXCDSTOFS33 4/57
TLXCDSUOFS33 4/57
TSXCANCA50 3/68
TSXCANCA100 3/68
TSXCANCA300 3/68
TSXCANCADD03 3/68
TSXCANCADD1 3/68
TSXCANCADD3 3/68
TSXCANCADD5 3/68
TSXCANCB50 3/68
TSXCANCB100 3/68
TSXCANCB300 3/68
TSXCANCBDD03 3/68
TSXCANCBDD1 3/68
TSXCANCBDD3 3/68
TSXCANCBDD5 3/68
TSXCANCD50 3/68
TSXCANCD100 3/68
TSXCANCD300 3/68
TSXCANKCDF90T 3/68
TSXCANKCDF90TP 3/68
TSXCANKCDF180T 3/68
TSXCANTDM4 3/68
TSXCBY010K 1/13
6/5
TSXCBY030K 1/13
6/5
TSXCBY050K 1/13
6/5
TSXCBY120K 1/13
6/5
TSXCBY180K 1/13
6/5
TSXCBY280K 1/13
6/5
TSXCBY1000 1/13
6/5
TSXCBYACC10 1/13
6/5
TSXCBYK9 1/13
6/5
TSXCRJMD25 4/23
TSXCSA100 3/77
TSXCSA200 3/77
TSXCSA500 3/77
TSXCUSB485 4/23
TSXPCX1031 4/23
TSXSCA50 3/76
TSXSCA62 3/76
TSXSCPCM4530 3/77
TSXTLYEX 1/13
6/5
TWDXCAISO 3/76
TWDXCARJ003 3/77
TWDXCARJ010 3/77
TWDXCARJ030 3/77
TWDXCAT3RJ 3/76
U
UAGSBTCFUCD10 4/31
UAGSBTDFUWB13 4/31
UAGSEWLFFCD33 4/33
UAGSEWLFUCD33 4/33
UNYLAGZAUWB20 4/31
UNYLFZZAUWB12 4/31
UNYLHVZAUWB10 4/31
UNYLPCZAUCD10 4/31
UNYLTSZAUWB10 4/31
UNYSDUMFUCD20 4/23
UNYSDUZFFCD22 4/29
UNYSDUZFUCD22 4/29
UNYSMUZUCD22 4/31
Index Product reference index
1
2
3
4
5
6
7
8
9
10
7/22
U
UNYSPUEFFCD50 4/22
UNYSPUEFGCD50 4/22
UNYSPUEFTCD50 4/22
UNYSPUEFUCD50 4/22
UNYSPUEZFCD50 4/22
UNYSPUEZGCD50 4/22
UNYSPUEZGTCD50 4/22
UNYSPUEZLGCD50 4/22
UNYSPUEZLTCD50 4/22
UNYSPUEZLUCD50 4/22
UNYSPUEZTCD50 4/22
UNYSPUEZUCD50 4/22
UNYSPUEZUGCD50 4/22
UNYSPUMFGCD50 4/21
UNYSPUMFTCD50 4/21
UNYSPUMFUCD50 4/21
UNYSPUMZGCD50 4/21
UNYSPUMZGTCD50 4/21
UNYSPUMZSGCD50 4/21
UNYSPUMZSTCD50 4/21
UNYSPUMZSUCD50 4/21
UNYSPUMZTCD50 4/21
UNYSPUMZUCD50 4/21
UNYSPUMZUGCD50 4/21
UNYSPUSFGCD50 4/20
UNYSPUSFTCD50 4/20
UNYSPUSFUCD50 4/20
UNYSPUSZGCD50 4/20
UNYSPUSZGTCD50 4/20
UNYSPUSZTCD50 4/20
UNYSPUSZUCD50 4/20
UNYSPUSZUGCD50 4/20
UNYSPUXFFCD41 4/22
UNYSPUXFGCD41 4/22
UNYSPUXFTCD41 4/22
UNYSPUXFUCD41 4/22
UNYSPUXZFCD41 4/22
UNYSPUXZGCD41 4/22
UNYSPUXZTCD41 4/22
UNYSPUXZUCD41 4/22
UNYSPUZFUCD31E 4/27
UNYSRTZFUCD10 4/25
UNYUDEVFUCD21E 4/23
UNYUSE909CDM 4/23
UNYXCAUSB033 4/23
V
VJC104188 4/42
VJC104288 4/42
VJC109081 4/44
VJC109082 4/44
VJC109083 4/44
VJC109088 4/44
VJC109206 4/43
VJC109310-01-00 4/47
VJC109310-02-00 4/47
VJC109320-01-000 4/47
VJC109320-02-00 4/47
VJC109330-02-00 4/47
VJC109350-02-00 4/47
VJC109370-01-00 4/47
VJC109370-02-00 4/47
VJC109390-02-00 4/47
VJC109401 4/43
VJC109511 4/44
VJC109512 4/44
VJC109910 4/38
VJC109911 4/38
VJC109912 4/38
VJC109918 4/38
VJC109920 4/38
VJC109921 4/38
VJC109922 4/38
VJC309317 4/47
VJC309322 4/47
VJC309331-00-00 4/47
VJC309350-00-00 4/47
VJC309351-00-00 4/47
VJC309352-00-00 4/47
VJC309353-00-00 4/47
VJC309354-00-00 4/47
VJC309355-00-00 4/47
VJC309356-00-00 4/47
VJC903288 4/42
VJCNS101110 4/39
VJCNS101110-11 4/39
VJCNS101111 4/39
VJCNS101111-12 4/39
VJCNS101112 4/39
VJCNS101112-13 4/39
VJCNS101113 4/39
VJCNS101113-14 4/39
VJCNS101114 4/39
VJCNS101114-15 4/39
VJCNS101115 4/39
VJCNS101115-99 4/39
VJCNS101199 4/39
VJCNS102010 4/40
VJCNS102010-11 4/42
VJCNS102011 4/40
VJCNS102011-12 4/42
VJCNS102012 4/40
VJCNS102012-13 4/42
VJCNS102013 4/40
VJCNS102013-14 4/42
VJCNS102014 4/40
VJCNS102014-15 4/42
VJCNS102015 4/40
VJCNS102015-99 4/42
VJCNS102088 4/40
VJCNS102099 4/40
VJCNS102210 4/41
VJCNS102210-11 4/42
VJCNS102211 4/41
VJCNS102211-12 4/42
VJCNS102212 4/41
VJCNS102212-13 4/42
VJCNS102213 4/41
VJCNS102213-14 4/42
VJCNS102214 4/41
VJCNS102214-15 4/42
VJCNS102215 4/41
VJCNS102215-99 4/42
VJCNS102288 4/41
VJCNS102299 4/41
VJCNS103088 4/40
VJCNS103099 4/40
VJCNS103099-99 4/42
VJCNS103288 4/41
VJCNS103299 4/41
VJCNS103299-99 4/42
VJCNS103688 4/40
VJCNS103788 4/40
VJCNS103888 4/41
VJCNS103988 4/41
VJCNS301111 4/38
VJCNS301127 4/38
VJCNS301150 4/38
VJCNS301156 4/38
VJCNS301159 4/38
VJCNS305140 4/43
VJCNS305141 4/43
VJCNS305142 4/43
VJCNS305144 4/43
VJCNS305146 4/43
VJCNS305148 4/43
VJCNS305149 4/43
VJCNS305151 4/43
VJCNSL11-F11 4/39
VJCNSL11-L27 4/39
VJCNSL27-F12 4/39
VJCNSL27-L59 4/39
VJCNSL50-F13 4/39
VJCNSL56-L11 4/39
VJCNSL59-F13 4/39
VJCNSL59-L50 4/39
VJH209912 4/50
VJH209922 4/50
VJHNS204320 4/51
VJHNS204321 4/51
VJHNS204323 4/51
VJHNS211011 4/50
VJHNS211011-12 4/50
VJHNS211012 4/50
VJHNS211012-13 4/50
VJHNS211013 4/50
VJHNS211013-14 4/50
VJHNS211014 4/50
VJHNS211014-15 4/50
VJHNS211015 4/50
VJHNS211015-16 4/50
VJHNS211016 4/50
VJHNS211016-45 4/50
VJHNS211045 4/50
VJHNS211045-99 4/50
VJHNS211099 4/50
VJHNS212000 4/50
VJHNS212200 4/50
VJHNS212400 4/50
VW3A8114 3/76
VW3A8306 3/77
VW3A8306D30 3/77
VW3A8306R03 3/77
VW3A8306R10 3/77
VW3A8306R30 3/77
VW3A8306RC 3/76
VW3A8306TF03 3/76
VW3A8306TF10 3/76
VW3CANA71 3/69
VW3CANCARR03 3/69
VW3CANCARR1 3/69
VW3CANKCDF180T 3/69
VW3CANTAP2 3/68
VW3M3805R010 3/68
VW3M8223R30 2/33
X
XBTZ938 3/77
XGSZ24 3/76
XZCC12FCM50B 3/69
XZCC12FDM50B 3/69
XZCC12MCM50B 3/69
XZCC12MDM50B 3/69
XZCC12FCM50B 3/41
XZCC12FDM50B 3/41
XZCP1164L2 3/41
XZCP1164L5 3/41
XZCP1264L2 3/41
XZCP1264L5 3/41
Product reference index
Index
ART. 960539
The information and dimensions in this catalog are provided for the convenience of our customers.
While this information is believed to be accurate, Schneider Electric reserves the right to make
updates and changes without prior notication and assumes no liability for any errors or omissions.
Advantys, Altistart, Altivar, Citect, Compact, Concept, ConneXium, ConneXview, Ethway,
FactoryCast, FIPIO, FIPway, ISAway, Lexium, LL984, M340, Magelis, Merlin Gerin, Modbus,
Modicon, Modsoft, Momentum, OFS, OPC Factory Server, Osicoder, OsiSense, OsiTrack,
PCIway, Phaseo, PL7, PlantStruxure, Premium, Preventa, ProWorx, Quantum, SoCollaborative,
Symax, Tego, Telefast, TeSys, Transparent Ready, TSX Micro, Twido, TwidoSoft, TwidoSuite,
Uni-TE, Uni-Telway, Unity, Vijeo, Vijeo Designer, Vijeo Historian, X-Way, ZelioSoft, and Schneider
Electric and logo are trademarks or registered trademarks of Schneider Electric or its afliates in
the United States and other countries. Other trademarks used herein are the property of their
respective owners.
Design: Schneider Electric
Photos: Schneider Electric
© 2011 Schneider Electric. All rights reserved. 08/2011
DIA6ED2110104EN-US
http://www.schneider-electric.com/
Schneider Electric USA, Inc.
8001 Knightdale Blvd.
Knightdale, NC 27545
USA Customer Care Center
Tel: 888-778-2733
Schneider Electric Canada
5985 McLaughlin Rd.
Missassauga, Ontario, Canada L5R 1B8
Canada Customer Care Center
Tel: 800 -565- 6699
Modicon M340 automation platform
2011