LCS140114249TE

Lcs140114249Te LCS140114249TE LCS140114249TE CertsReports 178747 ProductFiles assets.mhint

Lcs140114249Te LCS140114249TE LCS140114249TE CertsReports 178754 ProductFiles assets.mhint

2016-04-06

: Pdf Lcs140114249Te LCS140114249TE CertsReports 178761 ProductFiles

Open the PDF directly: View PDF PDF.
Page Count: 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 1 of 21
EMC TEST REPORT
For
Dongguan Juling Electronics Technology Co., Ltd.
Bluetooth Headphone
Model No.: HE09
Additional Model No.: HE01, HE02, HE03, HE04, HE05, HE08, HE14, HE16
Prepared for : Dongguan Juling Electronics Technology Co., Ltd.
Address : Jiuwei Industrial Zone, Qishi Town, Dongguan City, Guangdong, China
Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd.
Address : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an
District, Shenzhen, Guangdong, China
Date of receipt of test sample : January 14, 2014
Number of tested samples : 1
Serial number : Prototype
Date of Test : January 14, 2014 - January 22, 2014
Date of Report : January 22, 2014
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 2 of 21
EMC TEST REPORT
ETSI EN 301 489-17 V2.2.1 (2012-09)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility
(EMC)standard for radio equipment; Part 17: Specific conditions for Broadband Data Transmission
Systems
Report Reference No.................. : LCS140114249TE
Date of Issue................................. : January 22, 2014
Testing Laboratory Name.......... : Shenzhen LCS Compliance Testing Laboratory Ltd.
Address......................................... :
1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue,
Bao'an District, Shenzhen, Guangdong, China
Testing Location/ Procedure......... :
Full application of Harmonised standards
Partial application of Harmonised standards
Other standard testing method
Applicant’s Name ....................... : Dongguan Juling Electronics Technology Co., Ltd.
Address......................................... : Jiuwei Industrial Zone, Qishi Town, Dongguan City, Guangdong,
China
Test Specification
Standard........................................ :
ETSI EN 301 489-1 V1.9.2 (2011-09)
ETSI EN 301 489-17 V2.2.1 (2012-09)
Test Report Form No. ................. : LCSEMC-1.0
TRF Originator............................. : Shenzhen LCS Compliance Testing Laboratory Ltd.
Master TRF .................................. : Dated 2011-03
Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to
its placement and context.
Test Item Description............... :
Bluetooth Headphone
Trade Mark ................................... : N/A
Model/ Type reference ................. : HE09
Ratings.......................................... :
DC 3.7V by battery(360mAh)
Recharge Voltage: DC 5V/0.22A
Result ………………………...... : Positive
Compiled by: Supervised by: Approved by:
Tree Zhan/ File administrators Fox Zhang/ Technique principal Gavin Liang/ Manager
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 3 of 21
EMC -- TEST REPORT
Test Result: Positive
The test report merely corresponds to the test sample.
It is not permitted to copy extracts of these test result without the written permission of the test
laboratory.
Test Report No. : LCS140114249TE January 22, 2014
Date of issue
Type / Model........................... : HE09
EUT......................................... : Bluetooth Headphone
Applicant............................... : Dongguan Juling Electronics Technology Co., Ltd.
Address.................................. : Jiuwei Industrial Zone, Qishi Town, Dongguan City,
Guangdong, China
Telephone............................... : /
Fax.......................................... : /
Manufacturer........................ : Dongguan Juling Electronics Technology Co., Ltd.
Address.................................. : Jiuwei Industrial Zone, Qishi Town, Dongguan City,
Guangdong, China
Telephone............................... : /
Fax.......................................... : /
Factory................................... : Dongguan Juling Electronics Technology Co., Ltd.
Address.................................. : Jiuwei Industrial Zone, Qishi Town, Dongguan City,
Guangdong, China
Telephone............................... : /
Fax.......................................... : /
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 4 of 21
TABLE OF CONTENTS
1. GENERAL INFORMATION..................................................................................................................5
1.1. PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ................................................................. 5
1.2. OBJECTIVE................................................................................................................................................ 5
1.3. RELATED SUBMITTAL(S)/GRANT(S) ......................................................................................................... 5
1.4. TEST METHODOLOGY ............................................................................................................................... 5
1.5. FACILITIES................................................................................................................................................ 5
1.6. SUPPORT EQUIPMENT LIST........................................................................................................................ 6
1.7. EXTERNAL I/O.......................................................................................................................................... 6
1.8. LABORATORY ACCREDITATIONS AND LISTINGS....................................................................................... 6
1.9. MEASUREMENT UNCERTAINTY ................................................................................................................ 6
1.10. DESCRIPTION OF TEST MODES ............................................................................................................... 6
2. SUMMARY OF TEST RESULTS...........................................................................................................7
3. RADIATED DISTURBANCE.................................................................................................................8
3.1. RADIATED EMISSION LIMIT ...................................................................................................................... 8
3.2. TEST EQUIPMENT...................................................................................................................................... 8
3.3. TEST CONFIGURATION.............................................................................................................................. 9
3.4. TEST PROCEDURE ..................................................................................................................................... 9
3.5. TEST DATA ............................................................................................................................................... 9
4. GENERAL PERFORMANCE CRITERIA FOR IMMUNITY TEST..............................................12
4.1. PERFORMANCE CRITERIA FOR CONTINUOUS PHENOMENA APPLIED TO TRANSMITTER (CT) ................... 12
4.2. PERFORMANCE CRITERIA FOR TRANSIENT PHENOMENA APPLIED TO TRANSMITTER (TT)....................... 12
4.3. PERFORMANCE CRITERIA FOR CONTINUOUS PHENOMENA APPLIED TO RECEIVER (CR).......................... 12
4.4. PERFORMANCE CRITERIA FOR TRANSIENT PHENOMENA APPLIED TO RECEIVER (TR) ............................. 12
5. ETSI EN 301 489-17 V2.2.1 §7.2 – RF ELECTROMAGNETIC FIELD (80 MHz -1000 MHz and 1400
MHz –2700 MHz) .......................................................................................................................................13
5.1. TEST EQUIPMENT.................................................................................................................................... 13
5.2. TEST CONFIGURATION............................................................................................................................ 13
5.3. TEST STANDARD..................................................................................................................................... 14
5.4. TEST PROCEDURE ................................................................................................................................... 14
5.5. TEST DATA ............................................................................................................................................. 14
6. ELECTROSTATIC DISCHARGE.......................................................................................................16
6.1. TEST EQUIPMENT.................................................................................................................................... 16
6.2. TEST CONFIGURATION............................................................................................................................ 16
6.3. TEST PROCEDURE ................................................................................................................................... 17
6.4. TEST DATA ............................................................................................................................................. 17
7. TEST SETUP PHOTOGRAPHS ..........................................................................................................19
7.1.PHOTO OF RADIATED MEASUREMENT ..................................................................................................... 19
7.2.PHOTO OF RADIO-FREQUENCY, CONTINUOUS RADIATED DISTURBANCE ................................................. 20
7.3.PHOTO OF ELECTROSTATIC DISCHARGE TEST ......................................................................................... 20
8. MANUFACTURER/ APPROVAL HOLDER DECLARATION........................................................21
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 5 of 21
1. GENERAL INFORMATION
1.1. Product Description for Equipment Under Test (EUT)
EUT : Bluetooth Headphone
Model No. : HE09
Frequency Range : 2402.00-2480.00MHz
Channel Number : 79 channel for Bluetooth V4.0 (DSS)
40 channels for Bluetooth V4.0 (DTS)
Channel Spacing : 1MHz for Bluetooth V4.0 (DSS)
2MHz for Bluetooth V4.0 (DTS)
Modulation Type : GFSK, π/4-DQPSK, 8-DPSK
Bluetooth Version : V4.0
Antenna Gain : Integral antenna, 2.0dBi(Max.)
Input Voltage : DC 3.7V by battery(360mAh)
Recharge Voltage: DC 5V/0.22A
1.2. Objective
ETSI EN 301
489-1
Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro
Magnetic Compatibility (EMC) standard for radio equipment and services; Part 1:
Common technical requirements
ETSI EN 301
489-17
Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic
Compatibility (EMC) standard for radio equipment Part 17: Specific conditions for
Broadband Data Transmission Systems
The objective is to determine EUT compliance with ETSI EN 301 489-1 V1.9.2 (2011-09) and
ETSI EN 301 489-17 V2.2.1 (2012-09).
1.3. Related Submittal(s)/Grant(s)
No Related Submittals.
1.4. Test Methodology
All measurements contained in this report were conducted with ETSI EN 301 489-1 V1.9.2 (2011-09)
and ETSI EN 301 489-17 V2.2.1 (2012-09).
1.5. Facilities
All measurement facilities used to collect the measurement data are located at 1/F., Xingyuan Industrial
Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China.
The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and CISPR
Publication 22.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 6 of 21
1.6. Support equipment List
Manufacturer Description Model Serial Number Certificate
-- -- -- -- --
1.7. External I/O
I/O Port Description Quantity Cable
USB Port 1 N/A
1.8. Laboratory Accreditations And Listings
Site Description
EMC Lab. : Accredited by CNAS, June 04, 2010
The Certificate Registration Number. is L4595.
Accredited by FCC, April 22, 2011
The Certificate Registration Number. is 899208.
Accredited by Industry Canada, May. 02, 2011
The Certificate Registration Number. is 9642A-1
Name of Firm : Shenzhen LCS Compliance Testing Laboratory Ltd.
Site Location : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District,
Shenzhen, Guangdong, China
1.9. Measurement Uncertainty
Item MU Remark
Uncertainty for Power point Conducted Emissions Test 2.42dB
3.54dB Polarize: V
Uncertainty for Radiation Emission test in 3m chamber
(30MHz to 1GHz) 4.10dB Polarize: H
2.08dB Polarize: H
Uncertainty for Radiation Emission test in 3m chamber
(1GHz to 25GHz) 2.56dB Polarize: V
1.10. Description Of Test Modes
MODE 1
Normal Operating (Bluetooth is active)
MODE 2
Idle
***Note: All test modes were tested, but we only recorded the worst case in this report.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 7 of 21
2. SUMMARY OF TEST RESULTS
Rule Description of Test Result
§7.1 Reference to clauses EN 301 489-1
§8.4 AC mains power input/output ports N/A
§7.1 Reference to clauses EN 301 489-1§8.3 DC power input/output
ports N/A*
§7.1
Reference to clauses EN 301 489-1
§8.2 Enclosure of ancillary equipment measured on a stand
alone basis
Compliant
§7.1 Reference to clauses EN 301 489-1
§8.5 Harmonic current emissions (AC mains input port) N/A
§7.1 Reference to clauses EN 301 489-1
§8.6 Voltage fluctuations and flicker (AC mains input port) N/A
§7.1 Reference to clauses EN 301 489-1§8.7 Telecommunication ports N/A*
§7.2 Reference to clauses EN 301 489-1 §9.3 Electrostatic discharge
(EN 61000-4-2) Compliant
§7.2
Reference to clauses EN 301 489-1
§9.2 Radio frequency electromagnetic field (80 MHz to
1 000 MHz and 1 400 MHz to 2 000 MHz)(EN 61000-4-3)
Compliant
§7.2 Reference to clauses EN 301 489-1§9.4 Fast transients, common
mode (EN 61000-4-4) N/A
§7.2 Reference to clauses EN 301 489-1§9.8 Surges
(EN 61000-4-5) N/A
§7.2 Reference to clauses EN 301 489-1§9.5 Radio frequency, common
mode (EN 61000-4-6) N/A
§7.2
Reference to clauses EN 301 489-1
§9.6 Transients and surges in the vehicular environment
(ISO 7637-2)
N/A*
§7.2 Reference to clauses EN 301 489-1§9.7 Voltage dips and
interruptions (EN 61000-4-11) N/A
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 8 of 21
3. RADIATED DISTURBANCE
3.1. Radiated Emission Limit
ETSI 301 489-1 V1.9.2 (2011-09)/EN 55022 Class B
Limits for radiated disturbance Blow 1GHz
FREQUENCY
(MHz)
DISTANCE
(Meters)
FIELD STRENGTHS LIMIT
(dBμV/m)
30 ~ 230 3 40
230 ~ 1000 3 47
Note: (1) The smaller limit shall apply at the combination point between two frequency bands. (2)
Distance refers to the distance in meters between the measuring instrument antenna and the
closed point of any part of the EUT.
Limits for radiated disturbance Above 1GHz
FREQUENCY
(MHz)
DISTANCE
(Meters)
Average Limit
(dBμV/m)
Peak Limit
(dBμV/m)
1000-3000 3 50 70
3000-6000 3 54 74
Note: The lower limit applies at the transition frequency.
3.2. Test Equipment
Item Test Equipment Manufacturer Model No. Serial No. Last Cal. Due Cal.
1 EMI Test Receiver ROHDE & SCHWARZ ESCI 101142 2013-06-18 2014-06-17
2 EMI Test Receiver ROHDE & SCHWARZ ESPI 101840 2013-06-18 2014-06-17
3 3m Semi Anechoic
Chamber SIDT FRANKONIA SAC-3M 03CH03-HY 2013-06-18 2014-06-17
4 Amplifier SCHAFFNER COA9231A 18667 2013-06-18 2014-06-17
5 Amplifier Agilent 8449B 3008A02120 2013-06-16 2014-06-15
6 Amplifier MITEQ
AMF-6F-260
400 9121372 2013-06-16 2014-06-15
7 Spectrum Analyzer Agilent E4407B
MY4144029
2 2013-06-16 2014-06-15
8 Signal analyzer Agilent
E4448A(Exte
rnal mixers to
40GHz)
US44300469 2013-06-16 2014-06-15
9 Loop Antenna R&S HFH2-Z2 860004/001 2013-06-18 2014-06-17
10 By-log Antenna SCHWARZBECK VULB9163 9163-470 2013-06-10 2014-06-09
11 Horn Antenna EMCO 3115 6741 2013-06-10 2014-06-09
12 Horn Antenna SCHWARZBECK BBHA9170 BBHA91701
54 2013-06-10 2014-06-09
13 RF Cable-R03m Jye Bao RG142 CB021 2013-06-18 2014-06-17
14 RF Cable-HIGH SUHNER SUCOFLEX
106 03CH03-HY 2013-06-18 2014-06-17
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 9 of 21
3.3. Test Configuration
Spectrum
analyzer
Horn
antenna
3m
4m
1m
Turntable
EUT
0.8m
Antenna
tower
Pre-amp
Above 1000MHz
3.4. Test Procedure
Please refer to ETSI EN 301 489-1 Clause 8.2.3 and EN 55022 Clause 6 for the measurement
methods.
3.5. Test Data
The worst test mode of the EUT was Mode 1, and its test data was showed as the follow:
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 10 of 21
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 11 of 21
Test Mode: Mode 1(above 1GHz) Tested by: Andy
Test voltage: DC 3.7V by battery Test Distance: 3m
Detector Function: Peak+AV Test Results: Passed
Polarization Frequency
MHz
Emission Level
dBμV/m
Limits
dBμV/m
Margin
dBμV/m
1402.53 55.45 37.66 70.00 50.00
-14.55 -12.34
1855.24 54.60 35.12 70.00 50.00 -15.40 -14.88
3217.61 56.41 32.92 74.00 54.00
-17.59 -21.08
3963.19 60.47 36.93 74.00 54.00
-13.53 -17.07
4449.68 61.89 39.48 74.00 54.00
-12.11 -14.52
Horizontal
4864.23 63.35 37.58 74.00 54.00
-10.65 -16.42
1383.15 53.91 34.40 70.00 50.00
-16.09 -15.60
1875.30 58.07 34.88 70.00 50.00
-11.93 -15.12
3226.21 58.05 37.51 74.00 54.00
-15.95 -16.49
3734.08 61.75 36.59 74.00 54.00
-12.25 -17.41
4446.38 59.93 38.14 74.00 54.00
-14.07 -15.86
Vertical
4855.59 63.49 36.47 74.00 54.00
-10.51 -17.53
1. Field strength limits for frequency above 1000MHz are based on average limits. However,
Peak mode field strength shall not exceed the average limits specified plus 20dB.
2. Measurements above show only up to 6 maximum emissions noted.
3. Data of measurement within this frequency range shown “ -- ” in the table above means the
reading of emissions are attenuated more than 20dB below the permissible limits or the field
strength is too small to be measured.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 12 of 21
4. GENERAL PERFORMANCE CRITERIA FOR IMMUNITY TEST
4.1. Performance criteria for Continuous phenomena applied to Transmitter (CT)
For equipment of type II or type III that requires a communication link that is maintained during the test, it
shall be verified by appropriate means supplied by the manufacturer that the communication link is
maintained during each individual exposure in the test sequence.
Where the EUT is a transmitter, tests shall be repeated with the EUT in standby mode to ensure that any
unintentional transmission does not occur.
4.2. Performance criteria for Transient phenomena applied to Transmitter (TT)
For equipment of type II or type III that requires a communication link that is maintained during the test,
this shall be verified by appropriate means supplied by the manufacturer during each individual exposure in
the test sequence. Where the EUT is a transmitter, tests shall be repeated with the EUT in standby mode to
ensure that any unintentional transmission does not occur.
4.3. Performance criteria for Continuous phenomena applied to Receiver (CR)
For equipment of type II or III that requires a communication link that is maintained during the test, it shall
be verified by appropriate means supplied by the manufacturer that the communication link is maintained
during each individual exposure in the test sequence. Where the EUT is a transceiver, under no
circumstances shall the transmitter operate unintentionally during the test.
4.4. Performance criteria for Transient phenomena applied to Receiver (TR)
For equipment of type II or type III that requires a communication link that is maintained during the test,
this shall be verified by appropriate means supplied by the manufacturer during each individual exposure in
the test sequence. Where the EUT is a transceiver, under no circumstances shall the transmitter operate
unintentionally during the test.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 13 of 21
5. ETSI EN 301 489-17 V2.2.1 §7.2 – RF ELECTROMAGNETIC FIELD (80 MHz
-1000 MHz and 1400 MHz –2700 MHz)
Please refer to ETSI EN 301 489-1, ETSI EN 301 489-17 and EN 61000-4-3.
5.1. Test Equipment
Item Test Equipment Manufacturer Model No. Serial No. Last Cal. Due Cal.
1 Signal Generator R&S SMR40 10016 2013-06-16 2014-06-15
2 Amplifier AR 500A100 17034 2013-06-18 2014-06-17
3 Amplifier AR 100W/1000M1 17028 2013-06-18 2014-06-17
4 Isotropic Field Monitor AR FM2000 16829 2013-06-18 2014-06-17
5 Isotropic Field Probe AR FP2000 16755 2013-06-18 2014-06-17
6 Bi-conic Antenna EMCO 3108 9507-2534 2013-06-18 2014-06-17
7 By-log-periodic Antenna AR AT1080 16812 2013-06-18 2014-06-17
8 EMS Test Software ROHDE &
SCHWARZ ESK1 N/A 2013-06-18 2014-06-17
5.2. Test Configuration
0.8m
Power Amp Signal
Generator EUT Monitoring by
using a camera
Control Room
9x6x6
EUT & Support
Units
PC Controller to
control S.G. & PA as
well as forward
power
3 meter
1.5 meter
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 14 of 21
5.3. Test Standard
ETSI 301 489-1 V1.9.2 (2011-09)/ (EN 61000-4-3: 2006+A1: 2008+A2: 2010)
Test level 2 at 3V / m
Test Level
Level Field Strength V/m
1. 1
2. 3
3. 10
X Special
Performance criterion: A
5.4. Test Procedure
The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. EUT is set 3
meter away from the transmitting antenna which is mounted on an antenna tower. Both horizontal
and vertical polarization of the antenna are set on test. Each of the four sides of EUT must be faced
this transmitting antenna and measured individually. In order to judge the EUT performance, a CCD
camera is used to monitor EUT screen. All the scanning conditions are as follows:
Condition of Test Remarks
---------------------------------------------- ----------------------------------
1. Fielded Strength 3 V/m (Severity Level 2)
2. Radiated Signal Unmodulated
3. Scanning Frequency 80 – 1000 1400-2700MHz
4. Dwell time of radiated 0.0015 decade/s
5. Waiting Time 3 Sec.
5.5. Test Data
PASS.
Please refer to the following page.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 15 of 21
RF Field Strength Susceptibility Test Results
Standard IEC 61000-4-3 ; EN 61000-4-3
Applicant Dongguan Juling Electronics Technology Co., Ltd.
EUT Bluetooth Headphone Temperature 24
M/N HE09 Humidity 53
Field Strength 3V/m Criterion
A
Test Mode Mode 1 Test Engineer Andy
Frequency
Range 80-1000MHz, 1.4GHz-2.7GHz, Test Date January 18, 2013
Modulation None Pulse ;AM 1KHz 80%
Steps 1%
Field Modulation Polarity Position Observation Result
3V/m Yes H/V
Right, Left, Front,
Back CT, CR PASS
3V/m Yes H/V
Right, Left, Front,
Back CT, CR PASS
3V/m Yes H/V
Right, Left, Front,
Back CT, CR PASS
3V/m Yes H/V
Right, Left, Front,
Back CT, CR PASS
Note:
During the test, the communication link is maintained. Unintentional transmission is not founded from the EUT.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 16 of 21
6. ELECTROSTATIC DISCHARGE
Please refer to ETSI EN 301 489-1 and EN 61000-4-2.
6.1. Test Equipment
Item Test Equipment Manufacturer Model No. Serial No. Last Cal. Due Cal.
1 ESD Simulator KIKUSUI KC001311 KES4021 2013-06-18 2014-06-17
6.2. Test Configuration
EN 61000-4-2 specifies that a tabletop EUT shall be placed on a non-conducting table which is 80
centimeters above a ground reference plane and that floor mounted equipment shall be placed on a
insulating support approximately 10 centimeters above a ground plane. During the tests, the EUT is
positioned over a ground reference plane in conformance with this requirement.
For tabletop equipment, a 1.5 by 1.0-meter metal sheet (HCP) is placed on the table and connected
to the ground plane via a metal strap with two 470 k Ohms resistors in series. The EUT and attached
cables are isolated from this metal sheet by 0.5-millimeter thick insulating material. A Vertical
Coupling Plane (VCP) grounded on the ground plane through the same configuration as in the HCP
is used.
470 k
Ω
VCP
10 cm
EUT
HCP
0.5 mm Thick
Insulator
Ground
470 kΩ
0.8 m
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 17 of 21
6.3. Test Procedure
ETSI 301 489-1 V1.9.2 (2011-09)/ EN 61000-4-2: 2009
Test level 3 for Air Discharge at ±8 kV
Test level 2 for Contact Discharge at ±4 kV
6.3.1. Air Discharge
This test is done on a non-conductive surface. The round discharge tip of the discharge electrode
shall be approached as fast as possible to touch the EUT. After each discharge, the discharge
electrode shall be removed from the EUT. The generator is then re-triggered for a new single
discharge and repeated 10 times for each pre-selected test point. This procedure shall be repeated
until all the air discharge completed.
6.3.2. Contact Discharge
All the procedure shall be same as Section 6.3.1. except that the tip of the discharge electrode shall
touch the EUT before the discharge switch is operated.
6.3.3. Indirect Discharge For Horizontal Coupling Plane
At least 10 single discharges (in the most sensitive polarity) shall be applied at the front edge of each
HCP opposite the center point of each unit (if applicable) of the EUT and 0.1m from the front of the
EUT. The long axis of the discharge electrode shall be in the plane of the HCP and perpendicular to
its front edge during the discharge.
6.3.4. Indirect Discharge For Vertical Coupling Plane
At least 10 single discharges (in the most sensitive polarity) shall be applied to the center of one
vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed
parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the
coupling plane, with this plane in sufficient different positions that the four faces of the EUT are
completely illuminated.
6.4. Test Data
PASS.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 18 of 21
Electrostatic Discharge Test Results
Standard IEC 61000-4-2 ; EN 61000-4-2
Applicant Dongguan Juling Electronics Technology Co., Ltd.
EUT Bluetooth Headphone Temperature 24
M/N HE09 Humidity 54
Criterion B Pressure 1021mbar
Test Mode Mode 1 Test Date January 18, 2013
Test Engineer Andy
Test Result Of Mode 1
Test Voltage Coupling Observation Result (Pass/Fail)
±2KV, ±4kV Contact Discharge TT, TR Pass
±2KV, ±4kV, ±8kV Air Discharge TT, TR Pass
±2KV, ±4kV Indirect Discharge HCP TT, TR Pass
±2KV, ±4kV Indirect Discharge VCP TT, TR Pass
Note:
During the test, the communication link is maintained. Unintentional transmission is not founded from
the EUT.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 19 of 21
7. TEST SETUP PHOTOGRAPHS
7.1.Photo of Radiated Measurement
Below 1G
Above 1G
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 20 of 21
7.2.Photo of Radio-frequency, Continuous radiated disturbance
7.3.Photo of Electrostatic Discharge Test
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 21 of 21
8. MANUFACTURER/ APPROVAL HOLDER DECLARATION
The following identical model(s):
HE01 HE02 HE03 HE04
HE05 HE08 HE09 HE14
HE16 -- -- --
Belong to the tested device:
Product description : Bluetooth Headphone
Model name : HE09
Remark: PCB board, structure and internal of these model(s) are the same,
So no additional models were tested.
---------------THE END OF REPORT-------------