VHC94/PVHC94 Asymmetric 9" × 4' VDT Parabolic / 1 or 2-Lamp T5, T5HO, T8 Project Information Project Name Type Catalog No. Date Construction Luminaire housing and end caps are die formed code gauge cold rolled steel. Louver and upper reflector surfaces are formed from low brightness iridescent suppressive specular anodized aluminum. Aluminum louver is secured in open or closed position by four torsion spring latches. Features • Optional 15 cell louver meets IES standard RP-1 glare control on room side • Ideal for today’s computer intensive electronic offices • Wide light distribution provides uniform illumination • Unique optical system eliminates glare • T8 Two lamp version features lamps stacked over/under • Low iridescent anodized aluminum louver and reflector • White powder coat finish painted after fabrication • Surface and pendant mount available • Symmetric and double wall wash distribution companions available Finish White painted parts are treated with a five stage phosphate bonding process and finished after fabrication with a minimum 90% reflective gloss baked enamel. location. NEC/CEC-compliant ballast disconnect is standard. Ceiling Compatibility Luminaire is available to fit most standard ceiling types. NEC-compliant T-bar clips supplied with all grid trim fixtures. See ceiling details on reverse. For continuous row mounting in hard ceilings use F trim and either EOR (end of row) or INT (intermediate mount) options. Contact your Columbia representative for compatibility information for specific ceiling types. Surface or Pendant Mount Standard luminaire is static. Air extract option available to remove room air and cool lamps. Companion surface or pendant mount version (SM ceiling type) matches performance and aesthetics of recessed versions. Installation Certification AIR HANDLING An access plate is furnished with each luminaire for fast wiring access from the plenum. No need to open fixture. Electrical All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924. Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. All ballast leads extend a minimum of 6" through access Ordering Information VHC 94 Model – – No. of Lamps VHC VDT Parabolic Example VHC94-132GT-LS113-S-EU-1ww 1 One 2 Two Ceiling Type GT Integral Cross Tee (Grid ends lay into standard T-bar, sides act as integral cross tee to support tile) F Overlap Flange G Lay-in (GT is typically recommended) SM Surface Mount (Static only) 1 LS – NO. CELLS CROSSWISE 1 One – – – AIR FUNCTIONS Voltage Options S Static H Heat Extract Only (No dampers) U 120V-277V 347 347V FO735 35K 75 CRI T8 Lamps Installed FO835 35K 80 CRI T8 Lamps Installed F5835 35K 80 CRI T5 Lamps Installed GLR Fast Blow Fuse GMF Slow Blow Fuse EL Emergency Battery Pack MSEE Master/Satellite End-to-End NO. CELLS LENGTHWISE distribution options 13 Thirteen 15 Fifteen (132 versions meet IES RP-1 on room side) 1WW Asymmetric Wall Wash Size Lamp Type Louver Finish Ballast 94 9" × 4' 28 4', T5: 28 Watt 32 4', T8: 32, 30, 28 or 25 Watt 54 4', T5HO: 54 or 51 Watt T8 only uses over/ under lamp position LS Low Iridescent Specular E Electronic T8, Instant Start (Std.) EP Electronic T5, Programmed Start (std. T5/T5HO, optional T8) ED Electronic dimming For dimming and other specific ballast vendor show as option Page 1/2 Rev. 11/18/09 1WW Parabolics / VHC94/PVHC94 asymmetric © 2009 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com VHC94/PVHC94 Asymmetric 9" × 4' VDT Parabolic / 1 or 2-Lamp T5, T5HO, T8 Photometric Data Test 10538 Test Date 6/10/03 Luminaire Data Zonal Lumen Summary VHC94-132G-LS113-EB81WW VHC Parabolic 9" × 48" 1-Lamp with 1 × 13 Cell Specular Asymmetric Louver B232I120 1.15 FO32/741 2850 35 N/A Luminaire Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Zone 0-30 0-40 0-60 0-90 0-180 wall illuminance Lumens % Lamp % Fixt. 622 1087 1746 1845 1845 21.8 38.2 61.3 64.7 64.7 Distance down from ceiling T8 VHC 1-Lamp 33.7 59.0 94.7 100.0 100.0 36" Indoor Candela Plot Average Luminance Angle Candela Values (Candela/Sq. M.) 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 0.0 22.5 45.0 67.5 90.0 653 655 648 629 604 571 532 484 430 368 295 152 8 3 2 1 1 0 0 653 610 565 534 535 563 588 599 580 534 463 335 46 6 3 1 1 0 0 653 580 557 633 720 771 792 791 750 643 511 398 250 96 67 14 2 1 0 653 557 609 738 823 874 913 887 760 687 595 463 363 289 208 83 12 1 0 653 554 627 763 846 906 944 858 721 649 549 440 380 368 287 114 22 1 0 90.0 Total Luminaire Efficiency 64.7% Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 61 Non-compliant $3.93 based on 3000 hrs. and $0.08 per KWH 72" 8 84" 7 96" Footcandle levels shown are initial for a single fixture. For data on specific room sizes, mounting distances and floor reflectance contact your Columbia representative. Recommended mounting distance from the wall is 36". A uniform wash will be provided if the mounting distance from the wall is between 12" and 48". Type G Type GT Side 6¼" 48" 87/8" Surface End Side For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 1½" allowed. 63/8" Type F End For lay-in installation in grid ceilings. Fixture mounts on exposed tees at ends of fixture. Self flange attached to side supports tile, eliminating need for intermediary tees. Designed for end tees of 1" width. Type SG 49" (48½" E.O.R., 481/16" Int.) 9½" 3½" 4½" 9½" 49" K.O. Dimensions A - 2" Dia. K.O. B - 7/32" Dia. K.O. C - 7/8" Dia. K.O. D - 5/8" Dia. K.O. NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 2/2 Rev. 11/18/09 10 Ceiling Compatibility Recessed (Type G) 24½" 6" 12" 18" 24" 30" 36" 42" 48" 54" 60" Vertical Footcandles Energy Data Dimensional Data 4 16 24 28 29 25 22 19 17 15 Side End Side For tile, plaster or plasterboard type ceilings. Overlapping extruded aluminum trim conceals edges of ceiling opening.Wing hanger suspension system included. For row mounting, row information is required. End For 9/16" slot grid type ceilings. Louver will be level with the ceiling plane. Slot grid tees must be field installed all around the fixture. For availability of side flanges, contact the factory. Flange kit rough in dimensions for single unit only: 97/8" × 481/8" Parabolics / VHC94/PVHC94 asymmetric © 2009 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2010:09:26 14:50:16-04:00 Modify Date : 2010:09:26 14:50:16-04:00 Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2010:09:26 14:50:16-04:00 Document ID : uuid:52c1a8af-e201-4ee3-add9-066a64a42665 Instance ID : uuid:64f2bc43-8c26-4b12-b94d-81ad46cc42ba Format : application/pdf Page Count : 2 Signing Date : 2010:09:26 14:50:16-04:00 Signing Authority : ARE Acrobat Product v8.0 P23 0002337 Annotation Usage Rights : Create, Delete, Modify, Copy, Import, Export Document Usage Rights : FullSave Form Usage Rights : Add, FillIn, Delete, SubmitStandalone Signature Usage Rights : ModifyEXIF Metadata provided by EXIF.tools