Qiaohua FM400KR Fog Machine User Manual

SHENZHEN QIAOHUA INDUSTRIES LIMITED Fog Machine

User Manual

400W Metal Fog Machine with Wireless Remote Control Set User Manual READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFETY INSTRUCTION CAUTION:-Risk of burn, fire or electrical shock. -For indoor use only. -Please read instruction manual before using. -Don’t immerse in liquid. -Not for space heating purpose.I. FOG MACHINE TECHNICAL SPECIFICATIONS Item Code:5724042                          Fuse: 5A, 125V Model: FM400-E                                       Preheat Time: 3~ 5 Minutes Rating Voltage: AC120V, 60Hz                        Fog Output: 2,000 CFM Power: 400W                                     Tank Capacity: 0.55 Liter Ambient Temperature: -10 ~ 45°C                      Dimensions: L236.5 × W147 × H194 mm     L9.3 × W5.7 × H7.6 inch II. RECEIVER: TECHNICAL SPECIFICATIONS Item Name: Receiver                            Model Number: QT-14R Rating Voltage: AC120V, 60Hz                          Working Current: 50mA Max. III. TRANSMITTER: TECHNICAL SPECIFICATIONS Item Name: Transmitter            Model Number: QT-14T Working Voltage: 12V DC                 Working Current: 15mA Max. Require: 1 x 12V, 27A Battery (Included)     WARNING:   To prevent risk of personal injury, fire, and electric shock: ●  Never leave unit unattended while plugged in. Unplug when not in use. ●  Read all important safety instructions and cautions.●  Connect only to a properly grounded outlet.●  Place product on a flat, level HARD surface and conn ect the cord to prevent the product from overturning.●  For use only in covered areas. Keep unit dry, do not expose to rain or moisture. Do not immerse unit.
●  Leave enough space for good ventilation. Keep unit cool and away from other objects.●  Use only with SVI Fog Liquid (sold separately).●  Do not operate unit without fog liquid.●  Pour fog liquid carefully to avoid spills which could result in electrical shock. Do not use if liquid spills onto unit. Let unit dry completely before plugging in. ●  Do not overfill the liquid. ●  Keep away from flames and flammable/explosive substances to avoid fire or explosions. Never pour flammable liquids such as gas, perfume etc. into the fog machine. ●  Keep product and fog liquid out of reach of children. Use only under adult supervision. ●  Do not spray in the direction of flames or people. Stay at least 20 inches (50cm) from the nozzle at the front of the unit. ●  Do not obstruct the nozzle. ●  Do not open unit. No user serviceable parts inside, please refer to your vendor. Only an electrician can change the power cord. ●  Clean unit before storage to avoid damages. OPERATION INSTRUCTION: 1. Remove all packaging before use. NOTE: Please contact the store if you find any broken or missing parts. 2. Place the unit on a flat, level surface. 3. Unscrew the lid on the reservoir tank towards the back of the Fog Machine and pour the Fog Liquid inside. Do not spill Fog Liquid onto the unit. Do not overfill. If liquid gets into Fog Machine, allow unit to dry completely before plugging in. Do not cut, pinch, or break the tube connected through the tank lid. Close the lid to the reservoir tank tightly. Always make sure there is enough Fog Liquid in the tank before using the Fog Machine. 4. Plug the Receiver into the back of the Fog Machine. Now connect the unit with the proper power supply (120V AC). 5. Warm up time is approximately 3 - 5 minutes. When fully heated, the light on the Receiver will turn on and the Fog Machine will be ready to produce fog. 6. Remove the battery’s insulating piece at the back of the Transmitter for the first time you  use it. You can see the “ON/OFF” buttons on the transmitter. Push “ON” to produce fog, and press “OFF” to stop the flow of fog. 7. Unplug the unit before refilling the fog machine, and follow the directions in Step 3. 8. Unplug the unit when not in use. A.  Fog Machine B.  Receiver C.  Fog Liquid(not included) D. Power Cable E.  Transmitter
ADDITIONAL INFORMATION a) It is normal for condensation to appear on the nozzle of the Fog Machine. b) A small amount of fog may spray during or after operation. c) The unit will have to reheat after long bursts of use. The unit will stop operation for a short period  in  order  to  heat  up  to  operating  temperature  again.  While  this  is  happening,  fog cannot be produced. The light on the Receiver will turn on again when the unit is ready to generate more fog. MAINTENANCE & SERVICING Note:  Use  of  fogger  liquids  not  included  or  those  other  than  SVI  Fog  Liquid  are  not recommended and may result in blockage, leakage, or other damage to the unit. INSPECTION:Before each use, check unit for any cracks in the enclosure, remote control, cords, and plugs. Make sure there are no exposed wires. Do not use if any of the above conditions are found.CLEANING:Should you experience low fog output after many hours of continuous operation or after the machine has been idle or in storage for a long time, it is recommended to run a cleaning solution through the system to prevent the accumulation of particles in the heating element. a. While the unit is unplugged and cool, empty all Fog Liquid from the machine and replace with a fog machine cleaning solution in the tank. SVI Fog Machine Cleaning Fluid (not included) is recommended. Plug unit in and allow to warm as usual. b. Run unit in a well-ventilated area until tank is empty. c. Cleaning is now complete. All fog machines are prone to clogging due to the consistency of Fog Liquid and the high temperatures at which it vaporizes. However a well maintained machine should provide years of reliable use. STORAGE:It is important to remove all fluid from the unit when storing for an extended period of time.1. When the unit is unplugged and cool, empty all Fog Liquid from the machine. Plug in unit and     allow to warm as usual.2. Run unit in a well-ventilated area for 10-seconds to confirm tank is empty and dry.3. Store on a flat, level surface. Keep in a well-ventilated, cool and dry location.For best performance, operate unit for 10-minutes every 3 months. Follow the Operation Instructions and Storage instructions accordingly.FUSE REPLACEMENT If the Fog Machine does not work at all when it is connected to the power socket, then it is probably that the fuse has been broken.
WARNING: Risk of electric shock and fire. Disconnect from power socket before replacing the fuse. 1. Turn the fuse knob counterclockwise to reveal the fuse. 2. Replace the fuse with the same size and type fuse: 5A, 125V 3. Place fuse in cover and reinstall by turning clockwise. Be sure not to over tighten.Note: This  device  complies  with  Part 15  of  the  FCC  Rules.  Operation  is  subject  to  the following  two  conditions:  (1)  this  device  may  not  cause  harmful  interference,  and  (2)  this device must accept any interference received, including interference that may cause undesired operation.Caution:  Changes  or  modifications  not  expressly  approved  by  the  party  responsible  for compliance could void user’s authority to operate the equipment. NOTE: This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  B digital  device,  pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide reasonable protection against harmful interference in a residential installation. This equipment generates,  uses  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in accordance  with the  instructions,  may  cause  harmful  interference  to radio  communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment  does  cause  harmful  interference  to  radio  or  television  reception,  which  can  be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   -- Reorient or relocate the receiving antenna.   -- Increase the separation between the equipment and receiver.   -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   -- Consult the dealer or an experienced radio/TV technician for help. Congratulations on the purchase of your new fog machine! FOR INDOOR USE ONLY SAVE THESE INSTRUCTIONS© Seasonal Visions InternationalEmeryville, CA 94608 Tel: 510-428-3921All Rights ReservedMADE IN CHINA

Navigation menu