W and WIP Panel
I N S T A L L A T I O N
M A N U A L
Doc. - Ref. 230-WIP210
Last modification date : February 2015
Firmware version : XLP 05.21.03.XXX and later
WIP210 Panel
www.videofied.com
Introduction
I N S T A L L A T I O N
M A N U A L
Description		
Since 2002, RSI VIDEO TECHNOLOGIES provides the only wireless video verification on the market,
thanks to the Motion Viewer™ detectors and to the Videofied ®product range
After 2 years of development, RSI VIDEO TECHNOLOGIES is proud to present the new W alarm panel.
The W alarm panel is wireless and mains powered with a backup rechargeable battery (provided).
The W panel is the first Videofied ® alarm panel that can be used as a connected device.
This panel is intended for residential and commercial markets.
Like all the Videofied ® alarm panels, the W panel is compatible with every radio device manufactured
by RSI VIDEO TECHNOLOGIES.
Technology
The W alarm panel uses the S2View® patented technology. That interactive and wireless technology
ensures signal integrity. The bidirectional radio link maximizes the signal reliability.
AES encryption protects the communication between the panel and the devices. Transmission security
is optimal.
The jamming detection feature identifies any intentional jamming from a third party.
The supervision feature consists of transmitting signals between every device of the system and the W alarm
panel. Through the supervision, the detectors transmit every 8 minutes a presence signal.
The entire RSI VIDEO TECHNOLOGIES team wishes you a successful installation.
W and WIP Panel
www.videofied.com
Summary
I N S T A L L A T I O N
M A N U A L
Introduction................................................................................................2
Summary..............................................................................................3
1. W installation and setup...............................................................................4
1.1 Panel overview......................................................................................................4
1.2 Panel mounting......................................................................................................4
1.3 Ethernet cable connexion......................................................................................5
1.4 SIM card installation.............................................................................................5
1.5 Powering and initialization....................................................................................5
1.6 Indicator lights.....................................................................................................6
1.7 Pairing the keypad...............................................................................................6
2. W panel programming...........................................................................................7
ETHERNET parameters configuration...........................................................................11
3. W panel features guide......................................................................................15
3.1 Get to access level 4.........................................................................................15
3.2 How to arm/disarm the system.............................................................................15
3.3 Arming and siren mode configuration..................................................................16
3.4 Manage badges and access codes........................................................................17
3.5 Delete the keypad................................................................................................19
3.6 Read the event log.............................................................................................20
3.7 Golden rules.........................................................................................................20
4. Ethernet parameters.............................................................................................. 21
5. Transmitter events list ......................................................................................... 22
6. 2G3G error codes................................................................................................23
7. Security and certifications notes....................................................................... 24
8. Technical specifications..................................................................................... 26
W and WIP Panel
www.videofied.com
I N S T A L L A T I O N
M A N U A L
1. W installation and setup
1.1 Panel overview
WIS100
Siren connector
Ethernet cable
connection
SIM card installation
Status LEDs
Mini-USB connector
for power supply
Battery connector
COM button
INIT button
Locking screws
1.2 Panel mounting
Fix the back casing on the
wall using the three mounting
holes (4 mm diameter) as
shown.
Bracket holes
Mounting the panel is not
required for programming.
W and WIP Panel
www.videofied.com
1. W installation and setup
I N S T A L L A T I O N
M A N U A L
1.3 Ethernet cable connection
Only for models WIP 210/220/230, WIP 620/630 and WIP 720/730
Once the panel is fixed on the wall connect a RJ45 cable between the
site internet network and the panel Ethernet port.
When the panel attempts a transmission via Ethernet, a red LED on the
connector will flash. This will allow the installer to check whether the
panel is connected to a valid network.
Do not touch the RJ45 cable when the panel is powered.
IMPORTANT :
Only connect the panel on 10Base-T SELV networks.
1.4 SIM Card Installation
Insert a Mini-SIM 2FF SIM card in the location shown in the image.
Please refer to the markings for the insertion direction.
Use a M2M (machine-to-machine) 2G3G SIM card. If the panel is used
with a smartphone application, the SIM card shall be able to receive
SMS.
DO NOT insert or remove the SIM card while the panel is powered.
1.5 Powering and initialization
AC Power
•
Connect the backup battery.
•
Install the power supply inside or outside the panel box
depending on the needed cable length.
•
Connect the power supply to the panel mini-USB connector
•
Plug the power supply in an electrical outlet.
Initialization
•
Leave the panel open. The green status LED de statut verte is on.
Press and hold the INIT button for 6-7 seconds until the status LED
turns red for 1 second.
•
The red LED blinks several times then turns off. That procedure
resets the panel memory.
•
The panel is now reset, a Videofied® keypad has to be enrolled to
configure the panel.
W and WIP Panel
www.videofied.com
I N S T A L L A T I O N
M A N U A L
1. W installation and setup
1.6 Indicator lights
Red LED blinking
(every 3 seconds)
Red LED on
Green LED on
(AC power detected)
Green LED off
(AC power not detected)
Red LED off
Battery out of order
or not detected.
Low voltage on the
battery.
Normal operation
Low voltage on the battery.
Panel working on
battery. Battery OK.
Panel not powered or
out of order.
1.6 Pairing the remote keypad
•
Press briefly the panel INIT button and release for the enrollment of a programming keypad.
•
Insert 3 or 4 LS14500 Lithium batteries into the keypad.
•
Do not mount the keypad. It will display on of the following screens:
RSI (c) 2015
videofied.com
or
<=========XX=========>
•
Press on both CLR and ESC NO keys at the same time and release. The indicator LED on the keypad will blink rapidly. Wait
for the keypad to pair.
•
If the keypad does not pair up with the panel and shows “XX”, it certainly means that it is stilled paired to another
system. The keypad needs to be reset. Remove the batteries and press repeatedly on the keypad tamper switch for 30
seconds to 1 minute. Then proceed to the above steps.
W and WIP Panel
www.videofied.com
2. W panel programming
I N S T A L L A T I O N
M A N U A L
Use the keypad to program the panel
Keypad Display
Actions and comments
KEYPAD 1
RECORDED
OK or YES
< - LANGUAGE : - >
ENGLISH (UK)
for language selection
The system can also be programmed in : french, italian, german,
dutch, spanish, swedish, portuguese, danish, czech, turkish and
polish.
The language can be changed at any time once the panel is
programmed in the MAINTENANCE menu.
OK or YES
RADIO RANGE TEST?
OK or YES
RF TEST
x/9
Attendre
RF TEST
9/9
OK or YES
The radio range test must be run during the device learning
process in order to ensure proper pairing with the control
panel.
This test is important, it measures the strength of
communication between the device and the control panel.
The keypad will display a real time radio range value on a
scale of 9.
To receive the most accurate results you must run the radio
range test for at least 30 seconds.
Result must be 8 out of 9 or better for reliable
transmission.
RADIO RANGE TEST?
ESC
NO
INSTALLER CODE
4 TO 6 DIGITS THEN OK/YES
Using the alphanumeric keypad, enter the installer code of your
choice.
The installer code will be used for all future maintenance and
configuration.
This code is important to keep track of.
INSTALLER CODE:
OK or YES
There is no back door or Default codes to the system.
Please refer to the restriction rules for codes (Chapter 3.4).
Some codes are already used by default and therefore cannot
be used.
CONFIRM CODE
OK or YES
W and WIP Panel
www.videofied.com
2. W panel programming
CODE NAME :
I N S T A L L A T I O N
M A N U A L
You may name the installer code using the alphanumeric
keypad.
OK or YES
If using automatic setting (called installer default list),
enter the name of the list.
ACCESS 1
REGISTERED
Warning : If the wrong installer list name is used, it
cannot be set later, the system must be defaulted.
Wait
Leaving the name blank by pressing ESC NO , it will be
named ‘ACCESS 1’ by default.
ADJUSTING
DATE AND TIME
DATE (YEAR):
15/ /
To set the year
OK or YES
DATE (MONTH):
15/01/
To set the month
OK or YES
You may proceed in the same way for :
Day, Hour and Minutes
15/01/19 10:47
ENTRY COMPLETE !
CONNECTED TO
MONITOR. STATION?
OK or YES
ACCOUNT NUMBER :
ESC
NO
ACCOUNT NUMBER :
567001
Use the alphanumeric keypad to enter in a 4-8 digit account
number provided by the Central Station
OK or YES
PERIODIC TEST
PERIODIC TEST :
24 HOURS
Test Periodicity: 1 hour, 12 hours, 24 hours, 48 hours, 7 days
or no tests.
We suggest a 24 hours periodic test call.
To select periodicity
OK or YES
W and WIP Panel
www.videofied.com
I N S T A L L A T I O N
M A N U A L
2. W panel programming
TEST (hour) :
04:
OK or YES
TEST (minutes) :
04:15
OK or YES
CODE / TEST
MODIFICATION?
OK or YES
CODE / TEST
MODIFICATION
ESC
NO
ALARM: event transmitted upon occurrence.
Wait
Events list
ESC
NO
SERVER
ADRESSES ?
The CODE/STATE MODIF. menu is used to configure the
transmitted events to the monitoring station. Use the arrow
keys to toggle between events and OK or YES to modify.
ALARM/END: event is transmitted on occurrence and on
event restoral.
NOT TRANSMITTED: event is not transmitted, however it
will appear on the keypad.
Please liaise with your Monitoring Station to ensure
that the requested events to transmit are correctly set.
OK or YES
IP1 ADDRESS
0.0.0.0
ESC
NO
ADRESSES
SERVEUR ?
PORT 1
888
DOMAIN NAME 1
The IP1 address, Domain Name 1 and/or Port 1 are provided by the monitoring
station.
Leave Port details at 888 unless otherwise instructed.
Press OK or YES to enter/modify the parameter then OK or YES for validation.
WARNING : You will use either an IP address or a Domain name, but not both, leave
the Domain name blank if an IP address has already been entered.
ESC
NO
Press on the right arrow to configure IP/Domain name 2 and PORT2 (for the back-up
server), and IP/Domain name TMT and PORT TMT (to configure remote maintenance
server).
The panel transmits in priority to IP1 (or DOMAIN NAME 1) / PORT 1 then to
IP2 (or DOMAIN NAME 2) / PORT 2 as a backup.
STRATEGY:
ETH+2G3G
OK or YES
W and WIP Panel
www.videofied.com
I N S T A L L A T I O N
M A N U A L
2. W panel programming
STRATEGY:
ETH+2G3G
OK or YES
How the alarms and videos are transmitted to the monitoring station :
2G3G : 		 SIM card transmission only
ETH :		 Ethernet transmission only (not recommended***)
WLAN :		 Wi-Fi** transmission only (not recommended***)
ETH+2G3G :		 Ethernet* transmission with backup SIM card
2G3G+WLAN :		 Wi-Fi** transmission with backup SIM card
ETH+WLAN :		 Ethernet* transmission with backup Wi-Fi** (not recommended***)
ETH+2G3G+WLAN : Ethernet* transmission with backup Wi-Fi** then backup SIM card
*Only for models WIP 210/220/230, WIP 620/630 and WIP 720/730
**Only available when the WWB100 module is installed.
2G3G
PARAMETERS ?
***In case of internet loss or AC power loss, transmission failures can occur by using
Wi-Fi and/or Ethernet without a 2G3G line backup.
OK or YES
APN CODE
ESC
NO
2G3G
PARAMETERS ?
USER NAME
PASSWORD
The APN Code (Access Point Name), User Name and Password are supplied by the
mobile operator. Please make sure you have entered the code exactly as indicated
by your local SIM card operator.
Press OK or YES to enter/modify the parameter then OK or YES for validation.
ESC
NO
Note: When entering your SIM card settings, both APN codes, username and
password fields are case sensitive! It makes a difference between UPPER and
lower case letters.
2G3G LEVEL ?
To switch between UPPER and lower case, use the M/m key from CMA keypad or hold
a digit key (0-9) for XMA/XMB.
OK or YES
TEST IN PROGRESS
END = OK/YES
Once the 2G3G test completed, the keypad will display one of the following
results :
- A level between 0/5 and 5/5.
2G3G LEVEL
5/5 2G3G
- A GPRS Error code (please see Chapter 6 : 2G3G errors codes and contact your
technical support).
OK or YES
If the screens shuts down, press any key to light it up except OK or YES, ESC NO
or CLR.
2G3G LEVEL ?
ESC
NO
W and WIP Panel
The 2G3G level test can last several minutes. Do not interrupt the test or remove
the SIM card during the test.
IMPORTANT : Videofied will require a 3/5 grade or better for reliable
transmission of Video alarms.
www.videofied.com
10
I N S T A L L A T I O N
M A N U A L
2. W panel programming
ETHERNET parameters configuration
Only for models WIP 210/220/230, WIP 620/630 and WIP 720/730
IP
PARAMETERS ?
OK or YES
DHCP :
ENABLED
By setting the DHCP as ENABLED,
a new IP address will be assigned
dynamically to the panel every
time it connects to the network.
Network parameters will not be
asked.
ESC
NO
OK or YES
DHCP :
DISABLED
If the router forces a static IP
address for the panel, there will
then be a need to define DHCP
as DISABLED. You will then need
to fill in the following network
parameters fields :
PANEL IP
IP MASK
PRIMARY
DNS
Panel IP, IP Mask, Primary DNS,
Gateway and Secondary DNS
GATEWAY
Warning: Verify that the IP
address selected is available on
the Network and accepted by the
router.
SECONDARY
DNS
ESC
NO
IP
PARAMETERS ?
ESC
NO
ETH. STATUS ?
During this test, the panel tries to connect to the local Ethernet Network. The result of
this test can be:
•
If the connection is successful: the local IP of the panel will be displayed (you
can display other Ethernet parameters with the arrows				
).
•
ETHERNET OFF NO STATUS : the Ethernet module is switched off. Please verify
that the Ethernet cable is connected and try again..
•
NETWORK/CABLE MISSING : the panel doesn’t detect Ethernet Cable or
Network
OK or YES
TEST IN PROGRESS
OK/YES = END
PANEL IP
XXX.XXX.XXX.XXX
ESC
NO
ETH. STATUS ?
ESC
NO
W and WIP Panel
www.videofied.com
11
2. W panel programming
COMPATIBILITY
EN 50131 NORMS ?
I N S T A L L A T I O N
M A N U A L
For full compatibility with EN50131 norms, press OK or YES.
Otherwise, press ESC NO.
ESC
NO
OK or YES
AREAS CONFIGURATION
Press ESC NO to default the area names.
Enter the name of Area 1 and confirm with OK or YES.
OK or YES
Repeat the procedure for areas 2,3 and 4.
For further details, please refer to chapter 3.3.
AREA 1 NAME :
OK or YES
EXIT DELAY :
45 sec
Available delays are : 2 min, 1 min, 45 sec.
For the selection
OK or YES
ENTRY DELAY :
15 sec
Available delays are : 15 seconds, 30 seconds, 45 seconds,
1 minute et 2 minutes.
For the selection
OK or YES
RECORDING
DEVICES
PRESS PROGRAM
BUTTON OF DEVICE
Each device has a unique programming button or a specific
manipulation. Please refer to the Installation Sheet for the
device you would like to program.
DEVICE
RECORDED
OK or YES
RADIO RANGE TEST?
OK or YES
RF TEST
x/9
Attendre
RF TEST
9/9
W and WIP Panel
Please check the radio level of each device on its final
location.
The result must be 8 out of 9 as a minimum.
Please refer to the RF test section on page 6 for further
details.
www.videofied.com
12
2. W panel programming
I N S T A L L A T I O N
M A N U A L
RF TEST
9/9
OK or YES
RADIO RANGE TEST?
Each device is recorded in an area.
ESC
NO
Each area can be configured as delayed or immediate. Areas
are used to set up special arming modes as well.
AREA ALLOCATION :
AREA 1
To select the
device area
OK or YES
Please refer to the chapter 3.3 for further details about
special arming modes.
By default (area set as Automatic), area 1 is delayed whereas
areas 2, 3 and 4 are immediate. Recording a keypad or a
badge reader in an area will automatically delay that area.
NAME + LOCATION :
The name of the device shall contain every needed
information to be properly processed in case of alarm.
OK or YES
FUNCTIONAL
DEVICE TEST ?
During the functional device test, the device LED turns on
when it detects an intrusion.
OK or YES
TEST IN PROGRESS
END = OK/YES
OK or YES
ENTERING A NEW DEVICE ?
ESC
NO
Press OK or YES to enter another device or ESC NO to move on
to the next step.
Each system can embrace a maximum of 25 devices,
programming keypad included.
BADGE ENTERED ?
OK or YES
RECORDING A
NEW BADGE ?
ESC
NO
ESC
NO
END OF
CONFIGURATION
W and WIP Panel
Press OK or YES if you use one or more badges. ESC NO if you
are not using any badges.
These badges will be used as a first user access (Level 3) and
will be mandatory to access the engineer level (Level 4).
If you wish to use an user code, please skip this step and when
initial programming is completed go to the BADGES/ACCESS
CODES menu (please refer to chapter 3.4 for further details).
Badges and codes are limited to 49 user accesses and 1
engineer code.
www.videofied.com
13
I N S T A L L A T I O N
M A N U A L
2. W panel programming
When the configuration is over, close the panel box as shown below and lock the panel. You can find screws to lock the
panel inside the box (see chapter 1.1 on page 4). Then stick the provided tag to seal the panel.
Box locking and sealing is mandatory to comply with NF&A2P and EN50131 standards.
Locking screws
location
Sealing tag
The keypad displays :
OPERATION
COMPLETED?
OK or YES
SYSTEM CHECK
IN PROGRESS
Before completing programming make sure that no device is
tampered. Each device must be closed and its LED indicator
shall be turned off.
After initial programming has been completed, make use of the
menu overview document (available on our technical support
portal), to see full programming options.
INSTALLATION SUCCESSFUL !
W and WIP Panel
www.videofied.com
14
I N S T A L L A T I O N
M A N U A L
3. W panel features guide
3.1 Get to Access level 4
Tue 29/10
DISARMED
11:23
LVL:1
ACCESS LEVEL
ACCESS LEVEL
LEVEL : 1
OK or YES
To unlock and get access to the installer level 4, you need to successively enter TWO
codes (in any order) :
•
INSTALLER CODE (entered during intial programming)
•
USER CODE (Level3): the user must authorize the installer to get access to the
configuration of his panel.
ACCESS LEVEL
LEVEL : 4
OK or YES
BADGE OR CODE
OK or YES
3.2 How to Arm/Disarm the System
When in standby mode, the system can be armed with the remote keypad , the remote keyfob and/or the remote badge reader.
Full arming with
personal code
With remote
keypad
Enter your user code
and press OK or YES
With remote
badge reader
BR250
N/A
With remote
keyfob
N/A
W and WIP Panel
Full arming with badge
Special Arming 1
Special Arming 2
Press
Press
enter your user code
enter your user code
and press OK or YES
and press OK or YES
N/A
N/A
Present your badge on
the keypad
( XMB model only)
Present your badge on
the badge reader
N/A
Press
Press
www.videofied.com
15
I N S T A L L A T I O N
M A N U A L
3. W panel features guide
3.3 Arming and Siren Mode Configuration
• Use		
to go to menu :
CONFIGURATION (LEVEL 4) > SPECIAL ARMING MODES > FULL ARM, SP1 or SP2
• There are 3 different arming modes :
FULL ARM : Arming of all areas and all devices. Use a badge or a user code and press OK /
SP1 : Partial Arming (1) is enabled by entering the user code and pressing
SP2 : Partial Arming (2) is enabled by pressing
on the keypad or
on the keyfob.
and entering the user code. On the keyfob, SP2 is enabled by pressing
For each arming mode, it is possible to specify how each of the 4 areas will be armed and how the system will behave during an alarm.
Areas :
1 2 3 4
Each time you press the corresponding number, the system will toggle the arming 		
state for the respective area.
State :
A A A A
Press OK / YES after this configuration step. The system will then display what siren 		
mode will be in effect for this special profile. Select the siren mode using the direction
arrows then press OK / YES.
Armed
Siren
Immediate triggering of all sirens
Disarmed
Delay Beeps
Entry/Exit delay beeps, then triggering of all sirens
Perimeter
(by default : all opening contacts*)
Silent
No Sirens, No Beeps
External
(by default : all opening contacts
with external access*)
Without Siren
Beeps on the keypad only
* You can set your devices as : External, Perimeter, ou External +Perimeter. Please go to the menu:
CONFIGURATION (LVL 4) > AREAS AND DEVICES > DEVICES > DEVICES CONFIGURATION > DEVICE TYPE
W and WIP Panel
www.videofied.com
16
I N S T A L L A T I O N
M A N U A L
3. W panel features guide
3.4 Manage badges and access codes
Access Level
Access Level
Definition & Rights
LVL 1
Standby Level
LVL 2
Restricted USER level, where it is only possible to arm/disarm the system.
LVL 3
USER level, where it is possible to arm/disarm the system, check the event log, test the
devices.
Modifications of the settings are not possible at this level.
User Level 3 can create Level 2 or Level 3 access codes or badges.
INSTALLER level, where it is possible to modify the setup of the panel. .
LVL 4
To access Level 4, the approval of a Level 3 oe Level 2 user is required.
Installer Level 4 can creat the first Level 3 access code only.
Codes and badges get rights access to one of the 4 available levels of access.
How to return to the LVL1?
•
After 1 min of no use of the keypad and no tests running, the display returns to the standby display and LVL1.
•
When standby display, if the ESC NO key is held during 5s, the level is changed to LVL1.
W and WIP Panel
www.videofied.com
17
I N S T A L L A T I O N
M A N U A L
3. W panel features guide
Enter a new end user Badge/Code
Delete an end user Badge/Code
BADGES
ACCESS CODES
ENTER A
BADGE/CODE
Press twice on the
right arrow
OK or YES
ENTER A
BADGE/CODE
DELETING
BADGES/CODES
OK or YES
OK or YES
BADGE OR CODE
Badges/codes list
Enter a 4-6 digit user code and
Select badge/code
then
OK or YES
OK or YES
or present a badge in front of the reader
until you hear the registration beep.
CONFIRM THE
CODE
DELETING CODE
ACCESS 5
OK or YES
OK or YES
CODE NAME :
CODE
DELETED
OK or YES
ACCESS 2
ENTRY COMPLETE
Reserved Codes
Up to 49 codes (or badges) can be
registered into the panel with the engineer
code.
A code has 4 to 6 digits (0 to 9).
The table presents the reserved code
possibilities that cannot be used.
Those codes are used for maintenance or
as panic/duress codes.
A total of 186 codes are forbidden.
W and WIP Panel
Reserved Codes
000000
From 9998 to 9999
From 99998 to 99999
From 999898 to 999999
From 314157 to 314159
When a code is created (1000 for example),
the 2 next codes and previous codes (0998,
0999, 1001 and 1002) will be automatically
reserved.
The +1 code (1001) is used for disarming
under duress.
All user codes +1
The +2 code (1002) is used for panic.
All user codes +2
The -1 and -2 codes (0998 et 0999) are
reserved to prevent conflicts when creating a
new user code.
All user codes -1
All user codes -2
www.videofied.com
18
I N S T A L L A T I O N
M A N U A L
3. W panel features guide
3.5 Delete the keypad or any other device
ACCESS LEVEL
CONFIGURATION
OK or YES
GENERAL
PARAMETERS
AREAS AND
DEVICES
OK or YES
DEVICES
OK or YES
ADD A NEW
DEVICE
DEVICE
CONFIGURATION
OK or YES
Devices list
to select the device
and press
OK or YES
A1 : KEYPAD
KEYPAD 1
OK or YES
DELETE
OK or YES
< = = = = XX = = = = >
You can now remove the
batteries from the device
W and WIP Panel
www.videofied.com
19
I N S T A L L A T I O N
M A N U A L
3. W panel features guide
3.6 Read the event log
EVENT
LOG
OK or YES
When user disarms the system, the keypad indicates the last event.
SELECT LAST
EVENTS
In case of the user needs to read the full log file, use the keypad to go in EVENT LOG,
press OK or YES on SELECT LAST EVENTS and use arrow to list the events.
OK or YES
15/10/13
11:10
SYSTEM DISARMED
15/10/13
11:29
MODIFIED PARAMET
Press OK or YES for more information about an event
3.7 Golden rules
1.
Area 1 device are delayed by default (Area mode parameter
set as Auto). When you register a keypad or a badge reader
into an area set as Auto, that area will automatically be delayed.
2.
Never position a panel next to a high voltage electrical
cabinet. The interference will affect radio and 2G3G
performance.
3.
Press CLR to erase a typing mistake.
4.
7.
Do not fix the keypad at the beginning of the installation as it
will need to be portable during programming.
8.
Always clean the lens of the cameras after the installation. Use
a clean, dry cloth, taking care not to exert pressure on
the lens.
9.
Internal components are fragile, be careful opening or closing
the panel.
Never register the same device twice (delete from the system
first).
10.
LCD screen goes dark after 30 seconds of inactivity, press an
arrow or numeric key to light it up.
5.
The panel can register of up to 25 devices of all types,
including the keypad and the keyfobs.
11.
Infrared detectors should never be installed in stairs or close
to stairs (false alarm risks).
6.
Follow the Motionviewer installation instructions. Consider the
infrared field of detection when installing the Montionviewer
cameras, in order to protect goods or an entry point instead
of a zone.
12.
A colon display [:] means that the parameter can be changed.
W and WIP Panel
Press OK / YES to display the colon
www.videofied.com
20
I N S T A L L A T I O N
M A N U A L
4. Ethernet parameters
To configure Ethernet parameters, using the direction arrows, go to the menu :
Lvl. 4
CONFIGURATION
OK or YES
GENERAL PARAMETERS
OK or YES
ETHERNET
To configure or modify Ethernet Parameters, go to:
• IP Parameters:
If you wish to use the Ethernet transmission mode, two options are available:
DHCP Enable: IP address is assigned by the DHCP service on the network. (Dynamic IP address). This is the
default option.
2. DHCP Disable: IP address must be defined in Ethernet parameters. IP address will NOT be automatically obtained
from DHCP service on the network. Each connection from the panel to the network (alarms transmission), the
XT-iP will have the same connection parameters. You must first connect to the router in order to get the network
parameters and all available IP addresses. The following parameters must be filled in the IP PARAMETERS submenu: PANEL IP, IP MASK, GATEWAY, PRIMARY DNS, SECONDARY DNS.
1.
• Constant Ethernet:
Three options are available:
1. “Auto” Mode - We recommend this mode. If main powered, the panel will be connected constantly to the local
Network. In case of an alarm, the alarm will be sent in few seconds to the monitoring station. When the main
power is cut, the Ethernet module will switch off after a delay (DELAY BEFORE OFF – 30 by default) in order to save
battery life. In case of an alarm, the panel will at first connect to the local Network. It adds few seconds to the total
process of sending an alarm.
You can set the delay in this menu :
CONFIGURATION (LVL 4) > GENERAL PARAMETERS > ETHERNET > CONSTANT ETH. > DELAY BEFORE OFF.
2. “ON” Mode - The panel will be connected constantly to the local Network. This option will impact back-up
battery life.
3. “OFF” Mode - For each transmission of alarm and video, the panel will connect to the local Network.
•
PING reply, Time Out Server, Max Seg. Size:
• PING REPLY: Enables ping response.
• Time Out Server: In case of disconnection to the local Network, the panel will try after that time to re-connect.
• Max Seg. Size: Maximum size of packet sent.
W and WIP Panel
www.videofied.com
21
I N S T A L L A T I O N
M A N U A L
5. Transmitted events list
The W panel can be configured to enable or disable the transmission of specific
events like alarms or malfunctions.
The installer can modify the default sending settings for those events, although it
will end the EN50131 standard compliance.
These are the default transmitted events :
DEVICE (intrusions)
ALERT (Panic Buttons)
PANEL LOW BATT.
TAMPER
DEVICE LOW BATT.
PERIODIC TEST
DURESS CODE
FIRE
MEDICAL ASSIST.
ETHERNET CABLE
AC POWER LOSS (AC Power supply)
The following events are not sent by default :
PANEL RESET
PHONELINE FAULT
RADIO JAMMING
SUPERVISION
5 WRONG CODES
ALARM CANCEL
ARM/DISARM (On/Off)
ZONE BYPASS (bypass function enabling/dsiabling)
SWINGER SHUTDOWN
There is 3 different transmission states :
ALARM : event transmitted upon occurrence
ALARM/END : event is transmitted on occurrence and on event restoral
NOT TRANSMITTED : event is not transmitted, however it will appear on the keypad.
Example :
If the monitoring station system is set to receive arms and disarms, the ARM / DISARM parameter must be
changed from NOT TRANSMITTED to ALARM / END.
How to modify the transmission state
• At initial programming, right after the PERIODIC TEST CALL step:
CODE/STATE
MODIFICATION
Press OK or YES to access EVENT TRANS. MODIFICATION menu.
• After initial programming, using a remote keypad :
Use the arrows 		
to access :
CONFIGURATION (level 4) > CONFIGURATION MONITOR. STATION > MONITORING PARAMETERS > EVENT TRANS. MODIFICATION
Then use the arrows 		
W and WIP Panel
to determine the event to modify. Press OK or YES to edit.
www.videofied.com
22
I N S T A L L A T I O N
M A N U A L
6. 2G3G error codes
Security limitations on the SIM card must be disabled.
The PIN of the SIM card has to be disabled or 0000.
The following is a list of error codes that can appear after the 2G3G test.
2G3G LEVEL :
ERROR XXX
In case of 2G3G errors during initial programming, we strongly suggest to continue with
the installation and perform the 2G3G level test again once achieved.
This error checklist is provided for information purposes only.
This is not a comprehensive list, but it is representative of
most cases. Some events or codes are subject to change by
SIM card operators.
Codes
03 ou 04LP
Errors
No network coverage or no SIM card
inserted
003
SIM card not detected/not inserted
010
SIM not inserted
011
PIN code necessary
-> PIN code must be deactivated
However, the 2G3G level test errors results in the majority of
cases have the following causes :
•
SIM Card activation Delay:
Some operators require an additional delay up to 48 hours to
activate automatic data transmission. Please check with your
operator prior to installation.
•
APN CODE, USERNAME and PASSWORD :
The 2G3G settings are supplied by the operator. Please make
sure you have entered the code exactly as indicated by your
local SIM card operator.
012
PUK code necessary, SIM card blocked
013
Default SIM card
014
SIM card busy
015
Error on SIM
Note: When entering your SIM card settings, both APN codes,
username and password fields are case sensitive! (It makes a
difference between UPPER and lower case letters).
•
•
No network coverage
Typographical error in the APN Code,
username, password
To switch between UPPER and lower case, use the M/m key
from CMA keypad or hold a digit key (0-9) for XMA/XMB.
Insufficient GPRS Network:
•
SIM card not activated
030, 043,
057, 102,
132, ...
W and WIP Panel
When the panel is unable to find any signal, proceed to GPRS
level test in another location on site. You can also find the
network state or condition of use by directly contacting your
local operator.
www.videofied.com
23
I N S T A L L A T I O N
M A N U A L
7. Security and certification notes
Certifications
868MHz (WIP 210/220/230 and W 210)
Compliant with the annex IV from the R&TTE 1999/5/CE Directive
NF&A2P - 2 boucliers – suivant le référentiel NF324-H58
Matériels de sécurité électroniques, détection d’intrusion
CENTRALE D’ALARME + TRANSMETTEUR
Marque commerciale :
Référence Produits :
Videofied
Centrale WIP210
Videofied
Centrale WIP220
Videofied
Centrale WIP230
Videofied
Centrale W210
Normes :
NF EN50131-1: 2007 - Grade 2 – Classe II
NF EN50131-3:2009 - Grade 2		
NF EN50131-5-3:2005 - Grade 2
NF EN50131-6:2008 Grade 2 –Type B		
NF C 48-212:2004
NF EN50130-4:1995; A1:1998; A2:2003
NF EN50130-5: 1998 Classe II
Organisme certificateur :
CNPP Cert.
Route de La Chapelle Réanville CS22265
F—27950 SAINT MARCEL
Tel : +33(0)2.32.53.63.63
Fax: +33(0)2.32.53.64.46
Sites Internet : http://www.cnpp.com
Email : certification@cnpp.com
N° de Certification :
RTC 50131-3:2009
RTC 50131-6:2008
Organisme certificateur :
AFNOR Certification
11, rue François de Pressensé
93571 Saint Denis La Plaine Cedex
Tel : +33(0)1.41.62.80.00
Fax: +33(0)1.49.17.90.00
Sites Internet : http://www.afnor.org
et http://www.marque-nf.com
Email : certification@afnor.org
915MHz (WIP 620 /630)
UL 1610
USA FCC (Part 15C, 22H, 24E and 27)
Canada IC (RSS-210 Issue 8, RSS-132, RSS-133 and RSS-139)
920MHz (WIP 720/730)
Australia A-Tick
(AS/NZS4268, AS/CHS42 and AS/NZS 60950)
Ce symbole, apposé sur le produit ou sur son emballage, indique que ce produit ne doit pas être traité avec
les déchets ménagers. Il doit être remis à un point de collecte approprié pour le recyclage des équipements
électriques et électroniques. En s’assurant que ce produit est bien mis au rebut de manière appropriée, vous
aiderez à prévenir les conséquences négatives potentielles pour l’environnement et la
santé humaine. Le recyclage des matériaux aidera à préserver les ressources naturelles.
Pour toute information supplémentaire au sujet du recyclage de ce produit, vous pouvez
contacter votre municipalité, votre déchetterie ou la société qui a installé le produit.
W and WIP Panel
www.videofied.com
24
I N S T A L L A T I O N
M A N U A L
7. Security and certification notes
Notes de sécurité / (EN) Security notes / (DE) Hinweise zur Sicherheit
Français
•
•
•
•
Retirez la batterie avant toute
opération de maintenance !
Attention ! Il y a un risque d'explosion
si la batterie utilisée est remplacée
par un mauvais modèle !
Respectez la polarité lors de la mise
en place de la batterie !
Ne jetez pas la batterie usagée !
Ramenez-la à votre installateur ou à
un point de collecte spécialisé.
English
•
•
•
•
Remove the battery before any
maintenance !
WARNING, there is a risk of explosion
if a battery is replaced by an improper
model !
Observe polarity when setting up the
battery!
Do not throw the battery when it is
used! Dispose of it properly according
to Lithium Metal requirements
Deutsch
•
•
•
•
Batterien vor jeglichen Wartungsarbeiten
entfernen!
Vorsicht, es besteht Explosionsgefahr,
wenn eine Batterie durch eine Batterie
falschen Models ersetzt wird!
Achten Sie beim Einsetzen der Batterie auf
die Polung!
Entsorgen Sie Batterie nicht im normalen
Haushaltsmüll!
Bringen
Sie
Ihre
verbrauchten Batterie zu den öffentlichen
Sammelstellen.
FCC Regulatory Information for USA and CANADA
FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC
authorization to operate this equipment.
FCC Part 15.105 Class B
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance of 20 cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.
Operation is subject to the following two conditions:
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la Partie 15 des règlementations de la FCC et avec la norme RSS-210 de l’Industrie Canadienne.
Son fonctionnement est soumis aux deux conditions suivantes :
Cet appareil ne doit pas causer d’interférences nuisibles et
Cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant entraîner un fonctionnement indésirable.
W and WIP Panel
www.videofied.com
25
I N S T A L L A T I O N
M A N U A L
8. Technical specifications
Transmission
Electrical data
Communicator
Power Supply
Communicator type
2G & LAN Ethernet (WIP210)
W210 / WIP 210 / WIP 220 / WIP 230
2G (W210)
5VDC/1A Mini-USB connector
LAN Ethernet (WIP220 / WIP620 / WIP720)
AC/DC adapter (110/230VAC/50-60 Hz) available (WPS100)
3G
LAN
Ethernet (WIP230 / WIP630 / WIP730)
WIP 620 / WIP 630 / WIP 720 / WIP730
Security protocol
Frontel
12VDC/1A - Wire connection		
IP Stack
TCP/IP
Video
transmission
By
Frontel
protocol
to
Backup battery
central
monitoring
station
or
App
servers
Battery technology
Rechargeable 3.7V Lithium-ion battery
2G3G Antenna
Integrated
Battery voltage (Fully charged)
4.1 V
Low battery level
3.95 V
Optional modules
Guaranteed autonomy when the low battery level is reached
Wi-Fi
WWB100 (WLAN 802.11 b/g/n)
3 days with 6 alarms
Wired Input/Outputs
WIO100 (out of NF&A2P compliance)
Average current consumption in standby mode
600 µA
Wired
Siren
WIS100
Max consumption
1A
RF S2View® technology
Radio type
Bidirectionnal RF
Operating frequency
868MHz - WIP210/220/230 - W210 (Europe, South Africa, Asia)
915MHz - FHSS - WIP620/630 (USA, Canada, South America)
920MHz - FHSS - WIP720/730 (Australia, South America)
Transmission security
AES encryption algorithm
Radio jam detection
Yes
Supervision
Yes
Antenna
Integrated
Tamper Detection
Tamper
Wall and cover tamper detection
Video
Video format
Images per second
Image size
Video length
WMV or MPEG
320x240 or 640x480 pixels
4 to 12 seconds
Miscellaneous
Programming
Keypad or USB
Max number of devices
24
Max number of codes/badges
50
Arming modes
Areas
Event log
4,000 events stored on flash memory
Box
Physical and Environmental Data
Operating temperature
Maximum relative humidity
Material
International Protection Marking
Dimensions
Panel
-10°/+55°C
75%, non-condensing
ABS—ULV0
IP31 / IK06
143 mm x 200 mm x 44mm (LxWxD)
Installation/Mounting
Control Panel/Base
Two screws secures control panel cover to base; Three screws
secure control panel base to the wall
EMEA SALES
North American Headquarters
23, avenue du Général Leclerc
92340 BOURG-LA-REINE
FRANCE
E-Mail : emeasales@rsivideotech.com
1375 Willow Lake Blvd, Suite 103
Vadnais Heights, MN 55110
USA
E-Mail : usasales@rsivideotech.com
W and WIP Panel
www.videofied.com
26

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c014 79.156797, 2014/08/20-09:53:02
Create Date                     : 2015:02:27 11:52:30+01:00
Metadata Date                   : 2015:02:27 11:52:57+01:00
Modify Date                     : 2015:02:27 11:52:57+01:00
Creator Tool                    : Adobe InDesign CC 2014 (Windows)
Instance ID                     : uuid:fba3304a-35d7-4dba-a10b-afba1e189f1b
Original Document ID            : xmp.did:b6cf5c01-dd1a-7b43-b3e0-0d914de4fa70
Document ID                     : xmp.id:5e09bcb6-809f-9648-9180-78d3ab1d0650
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:63d319a8-6450-7942-af57-95f0bdeb087d
Derived From Document ID        : xmp.did:0a9d11a9-b181-dd40-9214-a93b6fc0f0d2
Derived From Original Document ID: xmp.did:b6cf5c01-dd1a-7b43-b3e0-0d914de4fa70
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2014 (Windows)
History Changed                 : /
History When                    : 2015:02:27 11:52:30+01:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Count                      : 26
Creator                         : Adobe InDesign CC 2014 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: X46WP01

Navigation menu