Radwin 5XACMOD 5 GHz Wireless Module User Manual Manual r1
Radwin Ltd. 5 GHz Wireless Module Manual r1
Radwin >
Contents
- 1. Manual r1
- 2. Manual
- 3. User Manual
Manual r1
AP0158770 5 GHz Wireless Module REFERENCE GUIDE Regulatory Compliance FCC/IC - Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and IC RSS standards. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. It is the responsibility of the installer to ensure that when using the outdoor antenna kits, only those antennas certified with the product are used. The use of any antenna other than those certified with the product is expressly forbidden by FCC rules 47 CFR part 15.204 and IC RSS standards. Warning Avertissement Caution Il est de la responsabilité de l'installateur de s'assurer que lorsque vous utilisez les kits d'antennes extérieures, seules les antennes certifiés avec le produit sont utilisés. L'utilisation d'une antenne autre que ceux qui sont certifiés avec le produit est expressément interdite par la réglementation FCC partie 47 CFR 15.204 et IC normes RSS. Outdoor units and antennas should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities. Failure to do so may void the product warranty and may expose the end user or the service provider to legal and financial liabilities. Resellers or distributors of this equipment are not liable for injury, damage or violation of regulations associated with the installation of outdoor units or antennas. The installer should configure the output power level of antennas according to country regulations and antenna type. AP0158770 Reference Guide Prudence Les unités extérieures et les antennes doivent être installés que par des professionnels expérimentés d'installation qui sont familiers avec les normes locales et les codes de sécurité et, si applicable, sont agréées par les autorités gouvernementales de réglementation compétents. Ne pas le faire peut annuler la garantie du produit et peuvent exposer l'utilisateur final ou le fournisseur de services d'obligations juridiques et financiers. Revendeurs ou distributeurs de ces équipements ne sont pas responsables des blessures, des dommages ou violation des règlements liés à l'installation des unités extérieures ou des antennes. L'installateur doit configurer le niveau de puissance de sortie des antennes conformément aux réglementations nationales et le type d'antenne. This equipment should be installed and operated with a minimum distance of 354cm between the radiator and your body. Warning Cet équipement doit être installé et utilisé à une distance minimale de 354cm entre le radiateur et votre corps. Avertissement The module is granted to operate under FCC certification in the 5.1 GHz and 5.8 GHz bands only. Warning This device complies with Part 15 of the FCC rules and with Industry Canada licenseexempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme la norme d'Industrie Canada exempts de licence RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: 1. Cet appareil ne peut pas causer d'interférences, et 2. Cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement de l'appareil. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada AP0158770 Reference Guide ii Overview The AP0158770 is a wireless module operating in the 5.1 GHz and 5.8 GHz frequency bands. It is a TDD OFDM radio supporting 5 MHz, 10 MHz, 20 MHz, 40 MHz and 80 MHz channel bandwidths. The wireless module cannot work as a stand-alone device. It can operate and be controlled only when attached to a digital main board and altogether assembled in an enclosure suitable for outdoor use. The assembly of the wireless module attached to the digital main board is hereafter referred to as ‘ODU’. The ODU in its various outdoor enclosures is manufactured by RADWIN. The wireless module is certified as a limited modular approval type under the FCC ID: Q3K5XACMOD for 5.1 GHz and 5.8 GHz bands. It is also certified under IC: 5100A-5XACMOD for 5.8 GHz band. Condition of Use The AP0158770 wireless module is a proprietary radio interface and can only be connected to digital boards manufactured by RADWIN. The ODU resides in an outdoor enclosure also manufactured and assembled by RADWIN or its subcontractors. The wireless module is not for sale to the general public. FCC rules and IC Regulation Restrictions The ODU firmware is factory programmed to operate under the FCC rules and Industry Canada regulation restrictions. The firmware is locked and inaccessible by any third party. As a result of the above the user interface allows both the installer and the user to control the ODU only within the boundaries of the regional restrictions. Antennas The AP0158770 wireless module is certified with a wide range of antenna types covering both Point-to-Point and Point-to-Multipoint systems up to 32 dBi gain. AP0158770 Reference Guide Certified Antennas Following is the list of antennas certified for use with the AP0158770 5 GHz Wireless Module: Antenna Type Manufacturer Model Number Antenna Max Gain (dBi) Sector Dual Pole Integrated 120 Deg RADWIN Ltd. MT0128930 11 Sector Dual Pole 120 Deg RADWIN Ltd. RW-9061-5004 11 Sector Dual Pole Integrated 95 Deg RADWIN Ltd. AM0135060 12 Sector Dual Pole 90 Deg RADWIN Ltd. RW-9061-5001 14 Sector Dual Pole 60 Deg RADWIN Ltd. RW-9061-5002 16.5 Sector Dual Pole Integrated 90 Deg RADWIN Ltd. MT0125250 13 Flat Panel Dual Pole Integrated RADWIN Ltd. AM0119960 16 Flat Panel Dual Pole Integrated RADWIN Ltd. AM0111760 16.5 Flat Panel Dual Pole Integrated RADWIN Ltd. MT0070760 24 Flat Panel Dual Pole External RADWIN Ltd. RW-9612-5001 23 Flat Panel Dual Pole External RADWIN Ltd. RW-9622-5001 29 Dual Pole Dish RADWIN Ltd. RW-9721-5158 29 Dual Pole Dish RADWIN Ltd. RW-9732-4958* 32 Shark Fin Monopole RADWIN Ltd. RW-9401-5002 12.5 * Not applicable for 4.9 GHz band Maximum Output Power 5725 – 5850 MHz band - FCC/IC The maximum output power can be set as follows, when operating in the 5.8 GHz band, under FCC and IC regulations. The power values are for PtP systems and PtMP systems with 0 to 6 dBi total antenna assembly gain. For PtMP systems the total EIRP is limited to 36 dBm. Therefore the output power for these systems, using higher than 6 dBi total antenna assembly gains will be reduced to comply with 36 dBm EIRP. The highest conducted output power shall be limited to 30 dBm in all channel bandwidths 5150 – 5250 MHz band – FCC The maximum output power can be set as follows when transmitting in the 5.1 GHz band, under FCC regulations. The total EIRP limit for PtP applications is 53 dBm. The total EIRP limit for PtMP applications is 36 dBm. The total EIRP limit for PtMP applications when transmitting at elevations above 30° relative to the horizon is 21 dBm. 5 MHz: 25.0 dBm 10 MHz: 27.0 dBm 20 MHz: 27.0 dBm 40 MHz: 27.0 dBm 80 MHz: 29.0 dBm AP0158770 Reference Guide US FCC IDs and Industry Canada Certification Numbers and covered configurations Channel BW [MHz] Center Freq. Range [MHz] 5730 - 5845 10 5731 - 5844 20 5735 - 5840 40 5745 - 5830 80 5765 - 5810 5157.5 - 5245 10 5162 – 5245 20 5165 – 5240 40 5172 - 5230 80 5190 - 5210 1, 2 1. The table is relevant for all RADWIN outdoor radio unit platforms into which the AP0158770 RF Module is assembled. 2. Under FCC ID: Q3K-5XACMOD, IC: 5100A-5XACMOD Radio parameters accessed by end-user The following parameters can be accessed by user: 1. 2. 3. 4. Output Power Frequency channel Channel bandwidth Antenna gain in external antenna type device AP0158770 Reference Guide
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 6 Language : en-US Tagged PDF : Yes Author : User Creator : Microsoft® Word 2010 Create Date : 2015:02:05 18:08:29+02:00 Modify Date : 2015:02:05 18:08:29+02:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools