ResMed AIR104G Continuous Positive Airway Pressure Device User Manual

ResMed Ltd Continuous Positive Airway Pressure Device Manual

a href="https://usermanual.wiki/ResMed" itemprop="url"> ResMed >

Manual

  ResMed Confidential Proprietary Information, not to be reproduced or made available to third parties  without prior consent from ResMed and not to be used in any unauthorised way.   ResMed Ltd 2016. DOC NO  378015 PAGE  1 of 35 SPECIFICATION – PRINTED MATERIALS REV  5  Rev Change Note Date document drafted Document prepared by (Name) Document Checked by (Name) 1  C36080 11 Mar 2014 Lisa Oliver Alison Besley (or delegate - refer to change note) 2  C36759 28 May 2014 Lisa Oliver Catherine Macalpine Alison Besley (or delegate – refer to change note) 3  C37528 18 Aug 2014 Verena Pirnbacher Alison Besley (or delegate – refer to change note) 4  mC0362  15 Jan 2016 Priya Varghese Alison Besley (or delegate – refer to change note) 5  mC0484 1 Aug 2016 Melanie Theaker Kristina Poeche or delegate refer to change note  AirCurve 10 VAuto S ST User Guide (device with humidifier)  AMER Eng Ref Reference for internal use only Not for printing or web publishing 1. DOCUMENT SCOPE This guide has been developed in Author-it. The content is written in AMER Eng in order to make sure that only one language (AmE) is used consistently for all Newport content in the production database. Imperial measurements, metric measurements as well as cm H2O and hPa are included where applicable. Once published from Author-it the following changes are applied to create this AMER Eng Ref: • Instances of hPa deleted with exception of:  Environmental conditions, Operating altitude: “Sea level to 8,500’ (2,591 m); air pressure range 1013 hPa to 738 hPa”. This guide includes content which is applicable to: Device:  AirCurve 10 VAuto S ST Integrated humidifier (standard water tub):  Yes Integrated humidifier (cleanable water tub): No CAM:  Yes Images and screens show an AirCurve 10 S device. 2. CHANGE HISTORY This change history provides an overall summary to assess importance of changes when documents are later introduced onto a BOM. Document versions, copyright and release dates are automatic updates and not detailed below.
  ResMed Confidential Proprietary Information, not to be reproduced or made available to third parties  without prior consent from ResMed and not to be used in any unauthorised way.   ResMed Ltd 2016. DOC NO  378015 PAGE  2 of 35 SPECIFICATION – PRINTED MATERIALS REV  5  REVISION 5 Changes trigger new document numbers for published multis if published multis are already available Section Heading Summary of change Languages/Country variations Update of AMER SPA/POB exception: Technical specifications: Remove FCC ID: 2ACHL-AIR104G, 2ACHL-AIR103G  IC: 9103A-AIR104G, 9103A-AIR103G The AirCurve 10 device complies with FCC Rules and Industry Canada rules. The AirCurve 10 device should be used at a minimum distance of 0.8" (2 cm) from the body during operation.  Additional information regarding the FCC Rules and IC compliance for this device can be found on www.resmed.com/downloads/devices  Therapy data Update paragraph to include ‘if wireless network is available’ Wireless – Notes section Add a new paragraph under the bullet points:  Please be aware that within the wireless network the availability and quality of the network may be affected by terrain, buildings and the weather. Wireless communication depends on network availability. Coverage is not available everywhere and varies by service.  Technical Specifications  classification Update classification table to: IEC 60601-1:2005+A1:2012 Technical Specifications – wireless module Update the technology section with the following: 4G (USA and Canada only) 3G (USA and Canada only) 2G GSM (all regions except USA and Canada) Technical Specifications – FCC rules Update with the following: FCCID: 2ACHL-AIR104G, 2ACHL-AIR103G IC: 9103A-AIR104G, 9103A-AIR103G The AirCurve 10 device complies with FCC Rules and Industry Canada Rules              REVISION 4 Backwards compatible change / Changes trigger new document numbers for published multis Section Heading Summary of change All  Technical review: >378013-8#1  Data according to D000-0245 Machines Data Rev. 55 Caring for your device The following Legionella warning added after the first paragraph: “Regularly clean your tubing assembly, water tub and mask to receive optimal therapy and to prevent the growth of germs that can adversely affect your health”.  The following LMR 880 was added to the list of warnings: “Regularly check the antibacterial filter for signs of moisture or other contaminants, particularly during nebulization or humidification. Failure to do so could result in increased breathing system resistance.”
Download:
Mirror Download [FCC.gov]
Document ID3173803
Application IDX9q1y1kQJ/tMIHr+vaKXNg==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize368.22kB (4602759 bits)
Date Submitted2016-10-25 00:00:00
Date Available2017-04-23 00:00:00
Creation Date2016-08-08 13:58:57
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2016-08-08 13:58:57
Document TitleManual
Document CreatorAdobe Acrobat Pro DC 15.17.20053
Document Author: Lisa Oliver
FCC ID Filing: 2ACHL-AIR104G

Navigation menu