Contents
- 1. Users Manual
- 2. Supplement
Users Manual
868 MHz & 433 MHz Wireless Supervised Photoelectric Smoke Detectors Installation Instructions GENERAL DESCRIPTION The Smoke Detectors are battery-powered photoelectric smoke detectors with a built-in supervised wireless transmitter. When sufficient smoke is detected or the test feature is operated, the detector will sound its alarm horn and the transmitter will send an ALARM message. If the alarm condition remains, the message will be repeated 2 or more times (with 65 second intervals). The Alarm output in the receiver will remain activated until the alarm condition is cleared. The smoke alarm provides the following features: Smoke Alarm/base lock discourages unauthorized removal of the smoke alarm by requiring a screwdriver to remove the alarm from the base. CleanMe™ Self-diagnostics monitors its own sensitivity and operational status. If the smoke alarms drifts out of the sensitivity range or fails internal diagnostics, it extinguishes its LED Internal Signal Outputs The smoke alarm provides the following signals for interfacing: • Alarm • Alarm restore • Low battery • Maintenance alert (Visible only) Selecting a Location Selecting a suitable location is critical to the operation of smoke alarms. This equipment should be installed in accordance with the National Fire Protection Association’s (NFPA) Standard 72. See Figure 2. A-8-1.2.1.C Are More Smoke Alarms Desirable? The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms. For this reason, it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection. The additional areas include the basement, bedrooms, dining room, furnace room, utility room, and hallways not protected by the required smoke alarms. The installation of smoke alarms in kitchens, attics (finished or unfinished), or garages is not normally recommended, as these locations occasionally experience conditions that can result in improper operation. Important: Regulations pertaining to smoke alarm installations vary from state to state. For more information, contact your local fire department or local authority having jurisdiction. In addition to NFPA 72, use the following location guidelines to optimize performance and reduce the chance of false alarms from the alarm: Locate ceiling-mounted smoke alarms in the center of a room or hallway at least 4 inches from any walls or partitions. • Locate wall-mounted smoke alarms so the top of the alarm is 4 to 12 inches below the ceiling. • Locate in a suitable environment as follows: − Temperature between 40ºF (4.4ºC) and 100ºF (37.8ºC)) − Humidity between 0 and 95% noncondensing • Locate away from air conditioners, heating registers and any other ventilation source that may interfere with smoke entering the alarm. • Mount smoke alarms on a firm permanent surface. • Locate away from large metallic objects when listed with a transmitter. Smoke Testing the Smoke Alarm Smoke alarms should be tested in place annually using smoke or canned aerosol simulated smoke. Follow the instructions on the canned smoke or use the following steps to test the alarm with smoke: Installing the Alarm 1. If you are using the alarm/base lock, remove the two knockouts on the mounting base. See Figure 3. 2. Slide the battery compartment cover away from the alarm to unsnap it and lift it off. See Figure 4. 3. Follow the write mode procedure as described in the receiver installation of the operational manual. 4. Observing proper polarity, insert two 3V lithium batteries into the alarm battery compartment and replace the battery compartment cover. 5. Write message will be sent automatically 10 seconds after installing the batteries. ∗ 6. Remove the red plastic dust cover from the alarm. The alarm is shipped with a dust cover for protection on construction sites with dusty environments. 7. Using the two screws and anchors provided, mount the base 8. Attach the alarm to the mounting base as follows: Line up the raised tab on the lip of the alarm with the slot on lip of the mounting base. See figure. 4 − Insert the smoke alarm into the base and turn clockwise approximately 15 degrees. It should snap firmly into place. Important: the alarm cannot be attached to the mounting base if no batteries are installed. − 9. Test the alarm (see Smoke Testing the Alarm). ∗ To generate an additional right mode message, disconnect the batteries for 30 seconds and then reconnect them. 1. 2. Hold a smoldering punk or cotton wick close to the smoke entry openings. Gently direct the smoke into the alarm for 20 seconds or until an alarm is indicated. BE SURE TO PROPERLY EXTINGUISH THE SMOKE SOURCE AFTER TESTING! The alarm LED should remain on and the alarm will sound a temporal rhythm until the Test/Silence button is pressed. The alarm automatically resets when smoke is no longer present. Understanding the Test/Silence Button The Test/Silence button on the alarm performs three functions as follows: Testing = Press the Test/Silence button for 2 seconds. The alarm performs a sounder test and a sensitivity test. Silence alarm = Press to silence the sounder during an alarm. After a few minutes, the sounder and alarm resume if smoke is still present. Silence trouble chirp = Press to silence a trouble chirp. The trouble chirp resumes after 24 hours if the trouble condition is not corrected. Testing the Alarm Sensitivity The smoke alarm provides a sensitivity level test mode that allows you to check the smoke alarms sensitivity using the Test/Silence button and the LED indicator on the alarm as follows: 1. 2. Press the Test/Silence button on the smoke alarm for 2 seconds. Once the test starts, the alarm LED flashes one to nine times. Count the number of times the LED flashes and use the following table to determine the status of the smoke sensitivity and what action to take, if any. Flashes Obscuration %/ft (approx) N/A 2, 3 N/A 8, 9 3.1 2.6 2.1 1.6 N/A Indication Action Unserviceable hardware fault detected. Detector is not sensitive enough. Detector is within normal sensitivity range. Reset unit and rerun sensitivity test. If the error persists, replace the unit. Detector is too sensitive. Clean the unit. Reset unit and run sensitivity test. If the error persists, replace the unit N/A Verify that the smoke chambers is snapped down securely. Clean the unit and replace the smoke chamber. After the flashes, if the sensitivity is within limits and all other tests pass, the alarm goes into alarm and resets after 3 seconds. If the sensitivity is not within limits, or an unserviceable hardware fault has been detected, the smoke alarm LED extinguishes until the alarm is serviced. Attaching and Removing the Smoke Alarm To remove the smoke alarm from the mounting base, grasp the alarm and turn it counterclockwise approximately 15 degrees. The smoke alarm should snap off of the mounting base. To remove the alarm from the mounting base when the alarm/base lock is used, insert a small screwdriver into the locking tab slot on the side of the base and press in while simultaneously turning the alarm counterclockwise 15 degrees. See Figure 5. Attach the smoke alarm to its mounting base as follows: − Line up the raised tab on the lip of the smoke alarm with slot on the lip of the mounting base. See Figure 4. − Insert the smoke alarm into the base and turn clockwise approximately 15 degrees. It should snap firmly into place. Understanding the LED The LED on the alarm indicates the status of the alarm as follows: FLASHING = Flashes every 9 seconds to indicate normal operation. ON = Detects smoke. OFF = Trouble or maintenance is required. When to Replace the Batteries The Smoke Detector requires two 3V lithium A batteries as listed on the battery compartment cover. The required batteries are available where other batteries are sold. Battery life is a minimum of 1 year and varies depending on how often the alarm is tested. When the batteries are low, the alarm extinguishes its LED and chirps every 30 seconds until the batteries are replaced. The sounder can be silenced for 24 hours by pushing the Test/Silence button. Replacing the Batteries Use only 3V lithium A batteries as listed on the battery compartment cover. Remove the alarm from the mounting base. See Attaching and Removing the Alarm. Slide the battery compartment cover away from the alarm to unsnap it and lift it off. See Figure 4. Remove the batteries and dispose of properly. Observing correct polarity, insert two new 3V lithium batteries into the battery compartment and replace the cover. Reattach the alarm to the mounting base. See Attaching and Removing the Alarm. Test the alarm (see Smoke Testing the Alarm). Cleaning the Smoke Chamber Clean the alarm cover with a dry or damp (water) cloth as needed to keep it free from dust and dirt When necessary, clean the alarm interior and replace the smoke chamber as follows: Remove the chamber from its mounting base. See Attaching and Removing the Alarm. Remove the batteries. See Replacing the Batteries. Slide a flat-blade screwdriver in the slot on the alarm cap and gently push the handle down to pry the cap up and off. See Figure 6. Press in on the sides of the chamber and pull it up and away from the alarm and discard. See Figure 7. Blow out or use a soft-bristled brush to remove dust and dirt from the smoke chamber base. Line the new smoke chamber up with the smoke chamber base and snap down into place. Replace the alarm cap as follows: Line the cap up with the smoke alarm. Insert the cap into the smoke alarm and turn clockwise approximately 15 degrees. It should snap firmly into place. Observing the proper polarity, put the batteries back in the alarm and replace the battery compartment cover. Reattach the alarm to its mounting base. . See Attaching and Removing the Alarm. Test the alarm sensitivity. (See Testing the Alarm Sensitivity). Maintaining the Alarm The Smoke Detectors are designed for easy field service and maintenance. When installed and used properly, they require minimal maintenance. The smoke alarm should be tested weekly. See Testing the Alarm Sensitivity and Smoke Testing the Alarm. When a Smoke Detector requires maintenance, it extinguishes its LED and initiates the external signals described in the following table. Signal Maintenance alert (LED OFF) Low battery Maintenance required Detector failed to power up on self test. Perform a sensitivity test. See Testing the Detector Sensitivity. If the problem persists, replace the detector. Batteries in the detector are low. Replace the batteries. FIRE PREVENTION AND ESCAPE The purpose of an early warning smoke alarm is to detect the presence of fire in its early stages and sound an alarm giving the occupants time to exit the premises safely. Avoid Fire Hazards No detection device can protect life in all situations. Therefore, safeguards should be taken to avoid potentially dangerous situations as follows: Do not smoke in bed Do not leave children home alone Never clean with flammable liquids such as gasoline. Properly store materials, Use general good housekeeping techniques to keep your home neat and tidy. A cluttered basement, attic or other storage area is an open invitation to fire. Use combustible materials and electrical appliances carefully and only for their intended uses. Do not overload electrical outlets. Do not store explosive and/or fast burning materials in your home. Even after proper precautions have been taken, fires can start. Be prepared. Be Prepared Practice the following steps to prepare you and your family in the event of a fire: Perform fire drills regularly. Use them to assure recognition of an alarm signal. Draw a floor plan and show two exits from each room. It is important that children be instructed carefully, because they tend to hide in times of crises. Establish one meeting place outside the home. Insist that everyone meet there during an alarm. This will eliminate the tragedy of someone reentering the house for a missing member who is actually safe. If you have children and/or physically challenged people residing in your household, use window decals to help emergency personnel identify the sleeping quarters of these individuals. In Case of Fire In the event of a fire, you should do the following: Leave immediately. Don't stop to pack or search for valuables. In heavy smoke, hold your breath and stay low crawl if necessary. The clearest air is usually near the floor. If you have to go through a closed door, carefully feel the door and door knob to see if undue heat is present. If they seem cool, brace your foot against the bottom of the door with your hip against the door and one hand against the top edge. Open it slightly. If a rush of hot air is felt, slam the door quickly and latch it. Unvented fire tends to build up considerable pressure. Be sure all members of the household realizes and understands this danger. Use your neighbor's phone or a street fire alarm box to call the fire department. The job of extinguishing the fire should be left to the professionals. WARNING! Smoke alarms CANNOT provide warnings for fires resulting from explosions, smoking in bed or other furniture, ignition of flammable liquids, vapors and gases, children playing with matches or lighters. ROKONET LIMITED WARRANTY CAUTION NOTICE Rokonet Electronics Ltd. and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 12 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller can not guarantee the performance of the security system which uses this product. Sellers obligation and liability under this warranty is expressly limited to repairing and replacing, at Sellers option, within a reasonable time after the date of delivery, any product not meeting the specifications. SELLER MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, AND MAKES NO WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR ANY PARTICULAR PURPOSE. IN NO CASE SHALL SELLER BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER. Sellers obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or consequential damages or delay. Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any persona; injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection. Buyer understands that a properly installed and maintained alarm may only reduce the risk of burglary, robbery or fire without warning, but is not insurance or a guaranty that such will not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR LOSS BASED ON A CLAIM THAT THE PRODUCT FAILS TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING FROM UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLERS MAXIMUM LIABILITY SHALL NOT EXCEED THE PURCHASE PRICE OF THE PRODUCT, WHICH SHALL BE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. This device complies with U.S. FCC Part 15 and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty. WARNING: This product should be tested at least once a week. This device may not cause interference, and This device must accept any interference, including interference that may cause undesired operation of the device. Changes or modifications not expressly approved by GardTec Ltd may void the user’s authority to operate this equipment. The communication quality of this unit may be affected by its surrounding environment. Nearby electrical equipment may interfere with its normal operation. The operation of this unit must, therefore, be tested at each installation since its transmission quality may vary as a result of operational conditions. Simultaneous transmissions from two different units may cause message interference resulting in loss of information. WARNING! LIMITATIONS OF SMOKE ALARMS Wireless smoke alarms are very reliable, but may not work under all conditions. No fire alarm provides total protection of life or property. Smoke alarms are not a substitute for life insurance. Smoke alarms require a source of power to work. This smoke alarm will not operate and the alarm will not sound if batteries are dead or not installed properly. Smoke alarms may not be heard. A sound sleeper or someone who has taken drugs or alcohol may not awaken if the alarm is installed outside a bedroom. Closed or partially closed doors and distance can block sound. This alarm is not designed for the hearing impaired. Smoke alarms may not always activate and provide warning early enough. Smoke alarms only activate when enough smoke reaches the alarm. If a fire starts in a chimney, wall, roof, on the other side of closed doors, or on a different level of the property enough smoke may not reach the alarm for it to alarm. SMOKE ALARMS ARE A SIGNIFICANT HELP IN REDUCING LOSS, INJURY AND EVEN DEATH. HOWEVER, NO MATTER HOW GOOD A DETECTION DEVICE IS, NOTHING WORKS PERFECTLY UNDER EVERY CIRCUMSTANCE AND WE MUST WARN YOU THAT YOU CANNOT EXPECT A SMOKE ALARM TO ENSURE THAT YOU WILL NEVER SUFFER ANY DAMAGE OR INJURY. 7 Specifications Voltage…………………………….…..2 X 3VDC Typical average standby current……………25µA Typical test current…………………………2mA Typical alarm current………………………70mA Battery life…………………………… 1year (min) Battery type…………...……………….3V lithium, ……………………...Duracell® DL123A, MN1500 …………………..Sanyo® and Panasonic® CR123A …………………………..Eveready® energizer E91 Low battery threshold…low battery signal at 2.70V Sounder…………………….85dB at 10 feet (3.3m) Low battery beep rate……...1 every 30 sec. + 2 sec. Sensitivity………………………………2.3%+0.8%/ft Operating temperature….……40º-100ºF (4.4º-37.8ºC) Operating humidity……….....0-95% non-condensing Color……………………………………………..white Alarm dimensions………..5.5” x 2.3” (14cm x 5.6cm) Base dimensions……4.88” x 0.38” (12.3cm x 0.95cm) Drift compensation adjustment………..0.5%/ft. max Marking (868.65 MHz, 433.92 MHz) …………..CE Listings (not including RF transmitter)………UL217, CSFM Radioactivity………………Contains NO radioactivity Transmitter Characteristics: Supervision Transmission: every 65 min. In order to continue improving its product, Rokonet Electronics Ltd. reserves the right to change specifications and/or designs without any prior notice. Changes or modifications to this equipment not expressly approved by the party responsible for compliance, Rokonet Electronics Ltd.. could void the user's authority to operate the equipment. RWT30EUV2: Not restricted for use in any European Community Countries. RWT32S86800A: Restricted for use in the Slovak Republic. Ordering Part Number P/N RWT32S86800A RWT30EUV2 ISRAEL Tel. +972 (0)3 9616555 Fax. +972 (0)3 9616584 Email: info@rokonet.co.il Description 868.65 MHz wireless smoke detector 433.92 MHz wireless smoke detector ITALY Tel. +39 02 392 5354 Fax. +39 02 392 5131 Email: info@rokonet.it SPAIN Tel. +34 91 4902133 Fax. +34 91 4902134 Email: sales@rokonet.es UK Tel. +44 (0)1527 576 765 Fax. +44 (0)1527 576 816 Email: info@rokonet.co.uk USA Tel. +1 305 592 3820 Fax. +1 305 592 3825 Email: sales@rokonetusa.com BRAZIL Tel. +55 21 2496 3544 Fax. +55 21 2496 3547 Email: rokonet-brasil@uol.com.br www.rokonet.com Rokonet Electronics Ltd. 01/05 5INT32 B
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2004:12:28 13:45:28+02:00 Modify Date : 2004:12:28 13:45:28+02:00 Page Count : 8 Creation Date : 2004:12:28 11:45:28Z Mod Date : 2004:12:28 11:45:28Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : Suzette_Y Metadata Date : 2004:12:28 11:45:28Z Creator : Suzette_Y Title : Microsoft Word - 5INT32 B 3.docEXIF Metadata provided by EXIF.tools