Copyright © 2015 Ruckus Wireless, Inc.Published November 2015, Part Number 800-70398-001 Rev A Page 1 of 4T710 Access PointMounting GuideThis Mounting Guide provides step-by-step instructions on how to field-install the Ruckus Wireless ZoneDirector T710 access point (AP).For detailed information on planning the installation, performing a site survey, and operating the T710, refer to the ZoneFlex Outdoor Access Point User Guide, available at https://support.ruckuswireless.com.WARNING: Only trained and qualified personnel should be allowed to install, replace, or service this equipment. WARNING: Installation of this equipment must comply with local and national electrical codes. CAUTION: Make sure that you form a 80mm - 130mm (3”-5”) drip loop in any cable that is attached to the AP or the building. This will prevent water from running along the cable and entering the AP or the building where the cable terminates. CAUTION: Be sure that grounding is available and that it meets local and national electrical codes. For additional lightning protection, use lightning rods and lightning arrestors. CAUTION: Make sure that proper lightning surge protection precautions are taken according to local electrical code. WARNING: Ruckus Wireless strongly recommends that you wear eye protection before mounting the T710.THIS GUIDE IN OTHER LANGUAGES请从以下网站获得该指南的简体中文版 https://support.ruckuswireless.com.Vous trouverez la version française de ce guide à l'adresse suivante https://support.ruckuswireless.com.こ の ガ イ ド の⽇本語版は https://support.ruckuswireless.com でご覧く ださい。이 가이드의 한국어 버전은 웹 사이트(https://support.ruckuswireless.com)에서 확인하시기 바랍니다 .Veja a versão em português (Brasil) deste guia em https://support.ruckuswireless.com.Puede ver la versión en español (América Latina) de esta guía en https://support.ruckuswireless.com.BEFORE YOU BEGINBefore deploying your Ruckus Wireless T710, verify that all items listed in Package Contents are included in the package. If any item is damaged or missing, notify your authorized Ruckus Wireless sales representative. Also, make sure that you have the required hardware and tools. REQUIRED HARDWARE AND TOOLS• Customer-supplied outdoor-rated three-wire (1-2mm2 or 14-18AWG) AC cable• Customer-supplied earth-ground wire (3-5mm2 or 10-12 AWG)• 1/2” (13mm) flat-blade screwdriver or equivalent• No. 2 Phillips screwdriver• Small flat-blade screwdriver• Torque wrench or torque screwdriver with sockets• Long-nose pliers• Electrical wire stripping and terminal crimping pliers• Pipe or pole --OR-- a sturdy flat surface• Electric drill with drill bits and customer-supplied wall anchors, flat washers, and hex nuts for flat-surface mount• Two customer-supplied M16 (5/8”) carriage bolts for main mounting bracket on a wooden pole• Four customer-supplied 6mm (1/4“) bolts or screws for main mounting bracket --OR-- Four customer-supplied 14mm (1/2“) bolts or screws for main mounting bracket --OR-- Four factory-supplied 1/2” (12.7mm) wide stainless steel adjust-able clamps, 2.5” (63.5mm) diameter, for main mounting bracket on smaller poles --OR-- Two 7/8” customer-supplied (22mm) wide stainless steel adjust-able clamps for main mounting bracket on larger poles•RulerPACKAGE CONTENTSA complete T710 field installation package includes all of the items listed below:• T710 Access Point (A in Figure 1), includes crimp-type earth-ground ring terminal• Two M25 data cable glands (B in Figure 1)• One main mounting bracket (C in Figure 1)• One U-joint bracket (D in Figure 1)• Nine sets 12mm M6 x 1 hex bolt with lock and flat washers (E in Figure 1)• One hook bracket (F in Figure 1)• One set 70mm M8x1.25 hex bolt with spring lock and flat washers (G in Figure 1)• One AP attachment bracket (H in Figure 1)• Four SAE32 steel clamps, 2.5-inch diameter (I in Figure 1)• One AC power cable input end connector and cap (J in Figure 1)• One safety cable (K in Figure 1)•This Mounting Guide Figure 1: T710 field-installation package contentsThe field installation package can also include: • Service Level Agreement/Limited Warranty Statement• Regulatory Statement• Registration card• Declaration of Conformity, if requiredNOTE: This kit can include extra screws, nuts and washers. You may use the extras wherever required.STEP 1: CONNECTING AND SEALING THE RJ-45 CABLESThe T710 may use zero, or one or two RJ-45 cables, one for Ethernet when configured as a Root AP (RAP), and one when the T710 is supplying PoE out to a peripheral device, such as a small cell or micro cell radio. When the T710 uses RJ-45 cables, connect and seal the cables using the M25 data cable glands (B in Figure 1).1Feed the end of the cable through the sealing nut, rubber O-ring, clamping ring assembly and cable gland base as shown in Figure 2.Figure 2: RJ-45 cable and cable gland assembly2Use a wide flat-blade screwdriver to remove the required (RESET/PoE OUT or PoE IN) blanking cap from the T710.3Connect the cable to the Ethernet port in the T710. 4Tighten the cable gland base into the T710 chassis to 7 N.m or 62 in-lbs.CAUTION! THE MINIMUM SOFTWARE REVISION FOR THE T710 IS ZONEFLEX (ZF) 9.12.2 OR LATER. DO NOT CONNECT THE T710 TO A RUCKUS WIRELESS CONTROLLER WITH ZF 9.12.1 OR EARLIER.F G HEACB DIJ KCable gland baseClamping ring assemblyRubber O-ringSealing nut
Copyright © 2015 Ruckus Wireless, Inc.Published November 2015, Part Number 800-70398-001 Rev A Page 2 of 45Wrap the clamping ring assembly around the rubber O-ring. Make sure that the clamping ring assembly fully encloses the rubber O-ring.6Seat the clamping ring assembly and rubber O-ring in the cable gland base.7Hand-tighten the sealing nut. STEP 2: ASSEMBLE THE MOUNTING BRACKET1Assemble the Mounting Bracket as shown in Figure 3.Figure 3: Assemble the mounting bracket2Continue with Step 3.STEP 3: ATTACH THE MOUNTING BRACKET TO THE AP1Attach the Mounting bracket to the bottom of the AP as shown in Figure 4. Figure 4: Use four bolts and lock washers to attach the mounting bracketSTEP 4: ATTACH THE MOUNTING BRACKET TO A POLE1Wrap the steel clamps around the pole, then insert steel clamps into the clamp slots on the mounting bracket. Figure 5: Steel clamp slots for a vertical pole2Tighten the clamps to 3 N.m or 27 in-lbs, or per manufacturer’s specifications.Figure 6: Bracket attached to pole 3Continue with Step 5.STEP 5: POWERING THE AP WITH AC1Separate the AC cable connector parts by unscrewing the boot from the cable gland and the cable gland from the connector housing.2Feed the end of the AC cable through the boot and cable gland.3Strip the AC cable as shown.4Insert the stripped part of the conductors into the appropriate terminals on the connector housing. The conductors are color-coded and must be connected to the appropriate terminals as shown in Figure 7.Typical AC wire colors:-  (Earth Ground): Green (US), Green/Yellow (EU)- 1 (Neutral/Return): White or Gray (US), Blue (EU)- 2 (Line/Hot): Black (US), Brown (EU)- 3 (not used)NOTE: The color coding of wire conductors varies by region. Before completing this step, check your local wiring standards for guidance.5Using a small screwdriver, tighten the small screws around the connector housing to fix the connector pins into the terminals.6Mate the cable gland with the connector housing, and then hand-tighten.
Download:
Mirror Download [FCC.gov]
Document ID2901675
Application IDH/RHuYugdjcsSKXWzqAPKw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize125.23kB (1565335 bits)
Date Submitted2016-02-11 00:00:00
Date Available2016-08-09 00:00:00
Creation Date2007-02-21 14:03:02
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2015-11-17 20:19:43
Document TitleSC8800-S Access Point Mounting Guide
Document CreatorFrameMaker 11.0.2
Document Author: Ruckus Wireless, Inc.
FCC ID Filing: S9GT710

Navigation menu