S and C Electric TSIICONTRL TripSaver Service Center Configurable Controller User Manual User Guide
S&C; Electric Company TripSaver Service Center Configurable Controller User Guide
Contents
- 1. User Guide
- 2. Module integration instructions
User Guide
S&C TripSaver® II Controller TripSaver II Controller Module User Guide Table of Contents Section Page Regulatory Information for FCC and IC . . . . . . . . . . 2 Hardware Contents of Controller Module . . . . . . . . . . . . . . . . . . . . 3 Section Page Software Download Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Install Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Launch Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Connect to a TripSaver II Controller Module. . . . . . 5 July 21, 2014© S&C Electric Company Instruction Sheet 461-506 Regulatory Information for FCC and IC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme aux normes Industry Canada exemptes de licence RSS standard(s). Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute interférence, y compris les interférences susceptibles de provoquer un fonctionnement indésirable. IMPORTANT! Changes or modifications not expressly approved by S & C Electric Company could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ——Reorient or relocate the receiving antenna. ——Increase the separation between the equipment and receiver. ——Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ——Consult the dealer or an experienced radio/TV technician for help. CAN ICES-3 (B)/NMB-3(B) 2 S&C Instruction Sheet 461-506 Hardware Contents of TripSaver II Controller Module AC Adapter Power Outlet Plug Adapters USB Dongle Contoller Module This Manual S&C Instruction Sheet 461-506 3 Software Download Software IntelliLink® TS-II controller module Setup Software is available for download only to customers who have purchased the Controller module. For each controller module purchased, the user is entitled to install and use S&C IntelliLink TS-II Controller module Setup Software on no more than two computers at a time. The latest software release is posted on the S&C Automation Customer Support Portal at www.sandc.com/support/ automation-customer-support-portal.asp. You will need a username and password to log into the portal. If you are a new S&C customer, complete the form in the lower section of the webpage and a new username and password will be sent to you. If you already have a password, click the LOG-IN TO SECURE SITE button. Enter username and password to log into the portal. Download the installer ILTS Setup-1.165.15712.0 from the portal. Install Software Double-click the downloaded installer file and follow the on-screen instructions. The installer will automatically install Microsoft .NET framework onto your computer if the required .NET version is missing. You will need administrative privileges to finish the installation. Launch Software Click the green ILTS icon on your desktop or in the start menu to launch IntelliLink TS-II Controller Module Setup Software. A warning screen will be displayed right after the software is launched. Read the message carefully and understand the warning. Proceed by clicking the green “I have read and understand the above warning” button. Once you launch the software, you can configure and save settings under the Standalone (Offline) mode. 4 S&C Instruction Sheet 461-506 Connect to a TripSaver II Controller Module To connect to a TripSaver II Controller module to apply your new settings, follow the steps below. Step 1 Install USB Transceiver A USB Transceiver must be installed on your computer to communicate with a TripSaver II Controller Module. Insert the USB Transceiver into any USB port on your computer. The installation process should be automatic. Note: You do not need the USB transceiver to be installed to install the software and to run the software in Standalone (Offline) mode. Step 2 Assemble Power Supply and Power Up TripSaver II Controller Module A TripSaver II Controller Module must be powered by the power module to enable its communication capability. Complete the following steps before attempting to communicate with your TripSaver II Controller Module. (a) Insert the connector from the power module onto the pins in the TripSaver II Controller Module as shown in the picture (b) Install the proper power outlet plug adapter onto the AC adapter. (c) Plug the AC adapter into a wall outlet. S&C Instruction Sheet 461-506 5 Connect to a TripSaver II Controller Module (d) To verify that your TripSaver II Controller Module is powered up, place a magnet next to the controller module as shown in picture and observe the LCD screen. If the LCD screen begins to scroll, it indicates that the unit has been successfully powered up. Your setup, at the end of Step 2, should look like the picture on the right. 6 S&C Instruction Sheet 461-506 Connect to a TripSaver II Controller Module Step 3 Obtain Transceiver ID A Transceiver ID unique to each TripSaver II Controller Module is needed to establish communications between your computer and the device. The ID consists of a 32-digit character string in the format of “0019C900.00020000. _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _”. You must enter the ID in order to communicate with each TripSaver II Controller Module. The Transceiver ID is also labelled on the top of the controller module side attached to each TripSaver II Controller Module when it leaves S&C Electric Company. S&C Instruction Sheet 461-506 7 Connect to a TripSaver II Controller Module Step 4 Connect to Device To connect to a TripSaver II Controller Module, select Connection > Connect to Device from the main menu or click the Connect to Device icon in the quick access toolbar. Make sure that the USB transceiver is already plugged into your computer. Next, a Transceiver ID Request dialog box will appear. Enter the Transceiver ID of the TripSaver II Controller Module you want to connect to, and click “OK” to connect. The first 16 digits of the ID are pre-typed. You only need to enter the last 16 digits. Enter last 16 digits here During the connection process, a status bar will be displayed. Wait about ten seconds for the connection process to finish, or click “Cancel” to cancel the connection process. Printed in U.S.A. You will be able to see the Status Screen after your TripSaver II Controller Module is successfully connected. Now, you can view existing settings, status information, and event logs of the TripSaver II Controller Module, or apply new settings to the device. 8 S&C Instruction Sheet 461-506
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2014:07:18 11:47:07-05:00 Creator : Adobe InDesign CC (Macintosh) Modify Date : 2014:07:18 11:55:50-05:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:07:18 11:55:50-05:00 Creator Tool : Adobe InDesign CC (Macintosh) Version ID : 1 Instance ID : uuid:8493b32c-9c45-4f5f-9742-831dd71d504e Original Document ID : adobe:docid:indd:5e627ac3-6e08-11de-b9de-d42728619a65 Document ID : xmp.id:7946243d-265e-49e9-afa7-750a586face5 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:231418e9-c2d2-4e6e-a8bc-daf320cda8df Derived From Document ID : xmp.did:9e7368be-f843-41c7-a607-3ac7b8a77206 Derived From Original Document ID: adobe:docid:indd:5e627ac3-6e08-11de-b9de-d42728619a65 Derived From Version ID : 1 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC (Macintosh) History Changed : / History When : 2014:07:18 11:47:07-05:00 Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 8EXIF Metadata provided by EXIF.tools