S and C Electric TSIICONTRL TripSaver Service Center Configurable Controller User Manual User Guide

S&C; Electric Company TripSaver Service Center Configurable Controller User Guide

Contents

User Guide

Download: S and C Electric TSIICONTRL TripSaver Service Center Configurable Controller User Manual User Guide
Mirror Download [FCC.gov]S and C Electric TSIICONTRL TripSaver Service Center Configurable Controller User Manual User Guide
Document ID2339311
Application IDN7b3vz5lPB+0IZlkA6IO+w==
Document DescriptionUser Guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize170.02kB (2125308 bits)
Date Submitted2014-07-29 00:00:00
Date Available2014-07-29 00:00:00
Creation Date2014-07-18 11:47:07
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2014-07-18 11:55:50
Document TitleUser Guide
Document CreatorAdobe InDesign CC (Macintosh)

S&C TripSaver® II Controller
TripSaver II Controller Module User Guide
Table of Contents
Section
Page
Regulatory Information for FCC and IC .  .  .  .  .  .  .  .  .  . 2
Hardware
Contents of Controller Module .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Section
Page
Software
Download Software. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Install Software.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Launch Software. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Connect to a TripSaver II Controller Module.  .  .  .  .  . 5
July 21, 2014© S&C Electric Company
Instruction Sheet 461-506
Regulatory Information for FCC and IC
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Cet appareil est conforme aux normes Industry Canada exemptes de licence RSS
standard(s). Son fonctionnement est soumis aux deux conditions suivantes : (1) cet
appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute
interférence, y compris les interférences susceptibles de provoquer un fonctionnement
indésirable.
IMPORTANT! Changes or modifications not expressly approved by S & C Electric Company
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
——Reorient or relocate the receiving antenna.
——Increase the separation between the equipment and receiver.
——Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
——Consult the dealer or an experienced radio/TV technician for help.
CAN ICES-3 (B)/NMB-3(B)
2   S&C Instruction Sheet 461-506
Hardware
Contents of
TripSaver II
Controller Module
AC Adapter
Power Outlet Plug Adapters
USB Dongle
Contoller Module
This Manual
S&C Instruction Sheet 461-506   3
Software
Download Software
IntelliLink® TS-II controller module Setup Software is available for download only to
customers who have purchased the Controller module. For each controller module
purchased, the user is entitled to install and use S&C IntelliLink TS-II Controller module
Setup Software on no more than two computers at a time. The latest software release is
posted on the S&C Automation Customer Support Portal at www.sandc.com/support/
automation-customer-support-portal.asp. You will need a username and password to
log into the portal. If you are a new S&C customer, complete the form in the lower section
of the webpage and a new username and password will be sent to you. If you already have
a password, click the LOG-IN TO SECURE SITE button. Enter username and password
to log into the portal. Download the installer ILTS Setup-1.165.15712.0 from the portal.
Install Software
Double-click the downloaded installer file and follow the on-screen instructions. The
installer will automatically install Microsoft .NET framework onto your computer if the
required .NET version is missing. You will need administrative privileges to finish the
installation.
Launch Software
Click the green ILTS icon on your desktop or in the start menu to launch IntelliLink TS-II
Controller Module Setup Software. A warning screen will be displayed right after the
software is launched. Read the message carefully and understand the warning.
Proceed by clicking the green “I have read and understand the above warning” button.
Once you launch the software, you can configure and save settings under the Standalone
(Offline) mode.
4   S&C Instruction Sheet 461-506
Connect to a TripSaver II Controller Module
To connect to a TripSaver II Controller module to apply your new settings, follow the
steps below.
Step 1
Install USB Transceiver
A USB Transceiver must be installed on
your computer to communicate with a
TripSaver II Controller Module. Insert the
USB Transceiver into any USB port on your
computer. The installation process should
be automatic. Note: You do not need the
USB transceiver to be installed to install
the software and to run the software in
Standalone (Offline) mode.
Step 2
Assemble Power Supply and Power Up TripSaver II Controller Module
A TripSaver II Controller Module must be powered by the power module to enable
its communication capability. Complete the following steps before attempting to
communicate with your TripSaver II Controller Module.
(a) Insert the connector from the power
module onto the pins in the TripSaver II
Controller Module as shown in the
picture
(b) Install the proper power outlet plug
adapter onto the AC adapter.
(c) Plug the AC adapter into a wall outlet.
S&C Instruction Sheet 461-506   5
Connect to a TripSaver II Controller Module
(d) To verify that your TripSaver II
Controller Module is powered up,
place a magnet next to the controller
module as shown in picture and
observe the LCD screen. If the LCD
screen begins to scroll, it indicates
that the unit has been successfully
powered up.
Your setup, at the end of Step 2, should
look like the picture on the right.
6   S&C Instruction Sheet 461-506
Connect to a TripSaver II Controller Module
Step 3
Obtain Transceiver ID
A Transceiver ID unique to each TripSaver II Controller Module is needed to establish
communications between your computer and the device. The ID consists of a 32-digit
character string in the format of
“0019C900.00020000. _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _”.
You must enter the ID in order to communicate with each TripSaver II Controller
Module.
The Transceiver ID is also labelled on the top of the controller module side attached to
each TripSaver II Controller Module when it leaves S&C Electric Company.
S&C Instruction Sheet 461-506   7
Connect to a TripSaver II Controller Module
Step 4
Connect to Device
To connect to a TripSaver II Controller Module, select Connection > Connect to
Device from the main menu or click the Connect to Device icon in the quick access
toolbar. Make sure that the USB transceiver is already plugged into your computer.
Next, a Transceiver ID Request dialog
box will appear. Enter the Transceiver
ID of the TripSaver II Controller Module
you want to connect to, and click “OK” to
connect. The first 16 digits of the ID are
pre-typed. You only need to enter the last
16 digits.
Enter last 16 digits here
During the connection process, a status
bar will be displayed. Wait about ten seconds for the connection process to finish,
or click “Cancel” to cancel the connection
process.
Printed in U.S.A.
You will be able to see the Status Screen
after your TripSaver II Controller Module
is successfully connected. Now, you can
view existing settings, status information,
and event logs of the TripSaver II Controller
Module, or apply new settings to the device.
8   S&C Instruction Sheet 461-506

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Create Date                     : 2014:07:18 11:47:07-05:00
Creator                         : Adobe InDesign CC (Macintosh)
Modify Date                     : 2014:07:18 11:55:50-05:00
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2014:07:18 11:55:50-05:00
Creator Tool                    : Adobe InDesign CC (Macintosh)
Version ID                      : 1
Instance ID                     : uuid:8493b32c-9c45-4f5f-9742-831dd71d504e
Original Document ID            : adobe:docid:indd:5e627ac3-6e08-11de-b9de-d42728619a65
Document ID                     : xmp.id:7946243d-265e-49e9-afa7-750a586face5
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:231418e9-c2d2-4e6e-a8bc-daf320cda8df
Derived From Document ID        : xmp.did:9e7368be-f843-41c7-a607-3ac7b8a77206
Derived From Original Document ID: adobe:docid:indd:5e627ac3-6e08-11de-b9de-d42728619a65
Derived From Version ID         : 1
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC (Macintosh)
History Changed                 : /
History When                    : 2014:07:18 11:47:07-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U3D-TSIICONTRL

Navigation menu