Savi Technology 650R-V2 RFID Tag Interrogator User Manual EchoPointSR650 101

Savi Technology Inc RFID Tag Interrogator EchoPointSR650 101

user manual pt 1

Download: Savi Technology 650R-V2 RFID Tag Interrogator User Manual EchoPointSR650 101
Mirror Download [FCC.gov]Savi Technology 650R-V2 RFID Tag Interrogator User Manual EchoPointSR650 101
Document ID1014795
Application IDrTj2iu/gBBtFC3pZzV7BKg==
Document Descriptionuser manual pt 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize214.76kB (2684495 bits)
Date Submitted2008-10-14 00:00:00
Date Available2008-10-16 00:00:00
Creation Date2008-09-19 11:22:21
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2008-09-19 11:22:33
Document TitleEchoPointSR650-101.book
Document CreatorFrameMaker 8.0
Document Author: mconde

Installation Guide
Savi Fixed Reader SR-650-101
Version 1.0
Published May 2008
Part number 805-04399-001 Rev C
Documentation for Savi Fixed Reader SR-650-101
Copyright © 2008 Savi Technology, Inc. All rights reserved. Unpublished
rights reserved under the Copyright Laws of the United States.
EchoPoint, Savi, Savi SensorTag, Savi SmartChain, Savi SmartStart,
Savi Technology, SaviTag, SmartChain, the EchoPoint Logo, the Savi Logo,
the UDAP Logo, and UDAP are trademarks or registered trademarks of
Savi Technology, Inc. in the United States and other countries.
Information in this manual is subject to change without notice and does not represent
a commitment from the vendor. The software and/or databases described in this
document are furnished under a license agreement or nondisclosure agreement. The
software and/or databases may be used or copied only in accordance with the terms
of the agreement. It is against the law to copy the software on any medium except as
specifically allowed in the license or nondisclosure agreement.
THIS DOCUMENTATION CONTAINS CONFIDENTIAL INFORMATION AND
TRADE SECRETS OF SAVI TECHNOLOGY, INC. USE, DISCLOSURE OR
REPRODUCTION IS PROHIBITED WITHOUT THE PRIOR EXPRESS
WRITTEN PERMISSION OF SAVI TECHNOLOGY, INC.
U.S. GOVERNMENT RIGHTS
Use, duplication or disclosure by the U.S. government is subject to restrictions
set forth in the Savi Technology, Inc. license agreement and as provided in DFARS
227.7202-1(a) and 227.7202-3(a) (1995), DFARS 252.227-7013(c)(1)(ii) (OCT
1988), FAR 12.212(a) (1995), FAR 52.227-19 or FAR 52.227-14 (ALT III), as
applicable. Savi Technology, Inc.
Other product names mentioned in this guide may be trademarks or registered
trademarks of their respective owners and are hereby acknowledged.
Savi Technology
A Lockheed Martin Company
351 East Evelyn Avenue
Mountain View, CA 94041-1530
Phone: 1-650-316-4700
Facsimile: 1-650-316-4750
www.savi.com
FCC Registration Required for Operation under Rule 15.240
Radio transmissions from the SR-650-101 are governed in the US by FCC Part 15 rules, and in
Canada by corresponding Industry Canada regulation RSS-210 . Still other regulations apply in
Europe and other countries.
The SR-650-101 is shipped with the default mode of operation corresponding to FCC 15.231. All
prior Savi equipment complies with 15.231. Equipment operating under this rule does not require
FCC Registration.
FCC Rule 15.240 offers some advantages in thru-put and flexibility for applications involving
containerized cargo. The SR-650-101 can be configured for operation under this rule only by a
qualified technician downloading factory-supplied configuration files.
There are restrictions in the geographical locations where such equipment may be deployed so as to
maintain a 40 km separation from five long-range radar sites in the US and Alaska. The FCC
requires notification of the locations where 15.240 operating equipment is to be installed. Savi
Technology, Inc. notifies the FCC of the initial shipping destination. However, it is the responsibility of
the end user to mail a notification of installation to the FCC as described in the form provided below
upon initial installation. It is also required that the user mail a new notification in the event the
equipment is re-located.
The form is to be mailed to:
Experimental Licensing Branch
Office of Engineering & Technology
Federal Communications Commission
445 12th Street, SW
Washington, DC 20554
ATTN: RFID Registration
Selected text from FCC Rule 15.240 Operation in the band 433.5 – 434.5 MHz
(a) “Operation under this section is restricted to devices that use radio frequency energy to
identify the contents of commercial shipping containers. Operations must be limited to
commercial and industrial areas such as ports, rail terminals and warehouses.”
(e) “To prevent interference to Federal Government radar systems, operation under the
provisions of this section is not permitted within 40 kilometers of the following locations:”
DoD Radar Site
Beale Air Force Base
Cape Cod Air Force Station
Clear Air Force Station
Cavalier Air Force Station
Eglin Air Force Base
Latitude
Longitude
39o08’10”N
41o45’07”N
64o55’16”N
48o43’12”
30o43’12”
121o21’04”W
070o32’17”W
143o05’02”W
097o54’00”W
086o12’36”W
FCC RFID REGISTRATION FORM
FOR FCC RULE 15.240
To:
Experimental Licensing Branch, OET
Federal Communications Commission
445 12th Street, SW
Washington, DC 20554
ATTN: RFID Registration
Subject: Registration for Savi Technology, Inc. Model SR-650-101 RFID Fixed Interrogator
The following information concerning the end user and installation location is hereby submitted as
required by FCC Rule 15.240:
End User Company Name:
Individual to Contact:
Mailing Address of Contact:
_________________________________
_________________________________
_________________________________
_________________________________
_________________________________
Street Address of Contact Office: _______________________________
_________________________________
_________________________________
Contact Telephone Number:
_________________________________
Contact E-Mail Address:
_________________________________
Street Address of Equipment Installation: ____________________________
____________________________
____________________________
Latitude: _______________________Longitude: ______________________
FCC ID of Equipment: KL7-650R-V2
_____________________________
Contact Signature
_________________
Date
Contents
1 Introduction
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Reader Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Network Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Tag Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Models and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Contacting Savi Global Support Services . . . . . . . . . . . . . . . . . . 13
2 Designating Locations and Connecting Cables
Planning a Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Connecting Power Cables to the Savi Fixed Reader . . . . . . . . . . 15
Connecting the Network Cables . . . . . . . . . . . . . . . . . . . . . . . . . 18
SaviNet Connection (RS-485) . . . . . . . . . . . . . . . . . . . . . . . . . 18
Ethernet Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Applying Power to the Savi Fixed Reader . . . . . . . . . . . . . . . . . . 25
3 Managing the Reader Network
Identifying the Savi Fixed Reader in SmartChain Site Manager . 28
Adding and Configuring the Reader in SmartChain Site
Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Discovering a Reader Using an Ethernet Connection . . . . . . . 29
Discovering a Reader Using a SaviNet Connection (RS-485) . 31
Savi Fixed Reader SR-650
Adding a Reader Manually Using an Ethernet Connection . . . 31
Setting the Host IP and Synchronizing Time . . . . . . . . . . . . . . 32
Configuring the Reader with Savi Retriever Using a SaviNet
Connection (RS-485) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Verifying Reader Communication . . . . . . . . . . . . . . . . . . . . . . . . . 34
4 Installing the Savi Fixed Reader
Positioning the Savi Fixed Reader . . . . . . . . . . . . . . . . . . . . . . . . 35
Mounting the Savi Fixed Reader . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5 Reader Sustainment and Maintenance
Repair and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
A Using Telnet to Connect to a Savi Fixed Reader
Setting Up the Savi Fixed Reader . . . . . . . . . . . . . . . . . . . . . . . . . 41
Configuring Your PC’s IP Address . . . . . . . . . . . . . . . . . . . . . . 41
Pinging the Savi Fixed Reader . . . . . . . . . . . . . . . . . . . . . . . . . 46
Configuring the Savi Fixed Reader . . . . . . . . . . . . . . . . . . . . . . 47
B Installing and Removing Heat Shrink Tubing
Installing Heat Shrink Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Removing Heat Shrink Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Savi Fixed Reader SR-650
CHAPTER
Introduction
You can use the Savi® Fixed Reader SR-650-101 to scan, detect,
and collect tag information. The SR-650-101 reader is designed to
communicate with all models of SaviTags, and forward the collected data
to the Savi SmartChain® Site Manager or SmartChain® Client Tools host
platforms. You can network multiple readers to cover large facilities.
Working with Savi Signposts, SR-650-101 readers provide a complete
RFID solution for real-time, end-to-end visibility of goods and critical
assets moving through the supply chain.
Figure 1-1 Savi Fixed Reader SR-650-101
Savi Fixed Reader SR-650-101 Installation Guide
CHAPTER
Introduction
Features
◆
Long-range, omnidirectional communication enables effective
monitoring of thousands of tagged items over a 328-foot (100 meters)
radius—ideal for yards, terminals, and warehouses.
◆
Ethernet connectivity supports wired and wireless installations, allowing
multiple readers to be easily networked together.
◆
Universal Data Appliance Protocol™ (UDAP™) provides
interoperability with other data collection devices, including bar code
scanners and other RFID readers.
◆
SmartChain Site Manager provides a seamless interface to the Savi
SmartChain platform and applications.
◆
Rugged, weatherproof packaging permits indoor and outdoor usage.
Reader Description
The Savi Fixed Reader SR-650-101 has an omnidirectional read pattern
with an adjustable range of up to 300 feet (91.44 meters), and can be
networked to provide cellular coverage of a nearly unlimited area. Its power
source can be 92 to 250 VAC or 12 to 24 VDC. A portable tripod mount,
a solar power unit, or a cable for powering the reader from a vehicle are all
available for use with the SR-650-101 reader.
The Savi Fixed Reader SR-650-101 operates at 433.92 MHz.
Network Communication
The Savi Fixed Reader SR-650-101 supports two types of network
protocols: SaviNet (RS-485) and Ethernet via RJ-45 connector;
10Base-T (TCP/IP).
The Savi Fixed Reader SR-650-101 is compatible with SaviNet installations
using the RS-485 protocol, and can be used in a mixed configuration that
includes both older Savi Fixed Interrogator 2.0 and SaviReader 410 models.
Savi Fixed Reader SR-650-101 Installation Guide
Reader Description
Tag Communication
The Savi Fixed Reader SR-650-101 can transmit control commands and
data over a UHF link to SaviTags. In return, the SaviTags transmit status
information, recognition codes, and data over the UHF link to the reader,
depending on the commands the tag received.
The Savi Fixed Reader SR-650-101 supports three UHF air interface
protocols for SaviTags, which are formats through which Savi products
transmit data:
Batch Collection System® (BCS)
◆ Extended BCS (EBCS)
◆ EchoPoint
◆
BCS and EBCS air protocols support 20-bit tag identification; EchoPoint
air protocol supports 32-bit tag identification.
The following table lists the SaviTag models that are compatible with the
Savi Fixed Reader SR-650-101.
Tag Model Number
Air Interface Protocols
Support
SealTag II
BCS
Yes
SealTag III
BCS
Yes
ST-410-108
EBCS
Yes
ST-410-113
No
ST-410-115
No
ST-410-118
EBCS
Yes
ST-412U1
EBCS
Yes
ST-602
EchoPoint
Yes
ST-604
EchoPoint
Yes
ST-645
EchoPoint
Yes
ST-654
BCS, EBCS, and EchoPoint
Yes
ST-655
BCS, EBCS, and EchoPoint
Yes
Savi Fixed Reader SR-650-101 Installation Guide
CHAPTER
Introduction
Specifications
The Savi Fixed Reader SR-650-101 can be mounted in permanent or
semipermanent sites, as well as in a mobile vehicle. SR-650-101 readers are
designed for indoor or outdoor use.
Specification
Description
Physical characteristics
Length: 12 inches (30.48 cm) in diameter
Height: 7 inches (17.78 cm)
Weight: 4.2 pounds (1.91 kg)
Case material: Polypropylene with UV inhibitors
Environment
Temperature: -26°F to +140°F (-32°C to +60°C)
operating; -40°F to +158°F (-40°C to +70°C) storage
Humidity: 100% condensing
RF receiver/transmitter
UHF transceiver (uplink and downlink)
Frequency: 433.92 MHz
Range: Typical transmit range is approximately 328
feet (100 meters) line of sight from the reader to
ST-65x and ST-41x tags. Typical transmit range is
approximately 100 feet (30.48 meters) line of sight
from the reader to ST-645 tags. Typical receive range
is approximately 328 feet (100 meters) line of sight
from all Savi tags
Modulation: FSK, deviation +/- 35KHz for receive,
+/- 50KHz for transmit
Data rate: 27.8Kbps
Air protocol: BCS Commands, EBCS Commands
(refer to Convergence RFID Air Protocol document)
EchoPoint Air Protocol 2.1 (refer to EchoPoint Air
Protocol document)
✦ Two-way UHF commands
✦ Seal extension commands
Data coding: Manchester
Rx Signal Strength Indicator (RSSI): Supported
Architecture: Single UHF board with two channels
Maximum transmit power: 0.15mW
Savi Fixed Reader SR-650-101 Installation Guide
Reader Description
Specification
Description
Network
Interface:
✦ UDAP protocol over Ethernet 10Base-T
✦ Reader network supports wireless connectivity
to host computer via external 802.11b
communications
Memory
On board non-volatile memory of 512 Kbytes for
interim tag data
Tag compatibility
All Savi RFID tags
Interfaces
✦ RS-232 interface via DB-9 female connector
Protocol: Savi Proprietary Serial Protocol
Data rate: 9600 Kbps
Flow control: CTS used for busy reader
indication; half duplex communication
Data format: 8 data bits, none parity, 1 stop
RS-232 signals: TXD, RXD, CTS, RTS (connected,
but not essential for operation)
✦ RS-485 2-wire differential via proprietary 4-pin
differential
Protocol: SaviNet Proprietary Protocol
Data rate: 38.4 Kbps
Data format: 8 data bits, none parity, 1 stop
✦ Ethernet via RJ-45 connector; 10Base-T
Antenna
Internal UHF: Orthogonal (omni) dual loop antenna
Shock and vibration
MIL STD 810E Method 514.4, Category 10
Protection type
Sealed to IP42, protection against objects larger than
.04 inches (1mm) in diameter and protection from
water falling as much as 15 degrees from vertical
Power
AC Source: Universal Power Supply
92-250 VAC, 50/60 Hz, 300 mA max
DC Source: 12-24 VDC, 500 mA
Indicators: Standard seven-segment LED display
Savi Fixed Reader SR-650-101 Installation Guide
CHAPTER
Introduction
Specification
Description
Regulatory requirements
Radiated emission (intentional):
U.S. emission standards as contained in FCC Part 15
Canada RSS210
European Community emission standards as
contained in EN 300 220 (433 MHz)
Electromagnetic Immunity:
ESD compliance
Exposed to 8 kV air discharge or 4 kV contact
discharge in accordance with EN 301 489-1
Radiated emission (unintentional):
U.S. emissions standards as contained in FCC Part 15
Medical Device EMC, IEC 60601-1-2
European Community emission standards as
contained in EN 301 489-1
Safety approval:
U.S UL 1950
European EN 60950
Ordnance safety:
HERO pending; unit will meet requirements for 24”
minimum safe separation distance
Accessories
10
Savi Mounting Kit SRA-1001 (not included); Savi
Heavy Duty Mounting Kit SRA-1024 (not included)
Savi Fixed Reader SR-650-101 Installation Guide
Reader Description
Models and Options
Savi fixed readers are supplied with cables necessary for operation.
Available accessories include a solar power unit, a vehicle power cable,
the AC power adapter and cables, spare batteries, a battery charger, and
mounting hardware. Contact your Savi Customer Service representative
for information about ordering additional equipment or accessories.
The table shows Savi Fixed Reader SR-650-101 models and options. All
product options are based on a common hardware and software platform
with a universal power supply. The difference between the product options
is the type of power plug with which the unit is shipped. All models operate
at 433.92 MHz.
Model
Description
Power/Plug
SR-650-101
Savi Fixed Reader SR-650-101,
RS-485 cable
92-250 VAC 50/60 Hz,
U.S. Plug
SR-650-101-2
Savi Fixed Reader SR-650-101,
RS-485 cable
92-250 VAC 50/60 Hz,
European Plug
SR-650-101-3
Savi Fixed Reader SR-650-101,
RS-485 cable
92-250 VAC 50/60 Hz,
Japan Plug
SR-650-101-6
Savi Fixed Reader SR-650-101,
RS-485 cable
92-250 VAC 50/60 Hz,
Type 2 Plug
SR-650-101-7
Savi Fixed Reader SR-650-101,
RS-485 cable
92-250 VAC 50/60 Hz,
U.K. Plug
SR-650-101-8
Savi Fixed Reader SR-650-101,
RS-485 cable
92-250 VAC 50/60 Hz,
China Plug
SR-650-101-9
Savi Fixed Reader SR-650-101,
RS-485 cable
92-250 VAC 50/60 Hz,
Australian Plug
SR-650-101-D
Savi Fixed Reader SR-650-101,
RS-485 cable
12 VDC, Pigtail wires
SR-650-101-T
Savi Fixed Reader SR-650-101,
RS-485 cable
Solar DC Input, Transportable
SR-650-101-E
Savi Fixed Reader SR-650-101,
Ethernet cable
92-250 VAC 50/60 Hz,
U.S. Plug
Savi Fixed Reader SR-650-101 Installation Guide
11
CHAPTER
12
Introduction
Model
Description
Power/Plug
SR-650-101-2E
Savi Fixed Reader SR-650-101,
Ethernet cable
92-250 VAC 50/60 Hz,
European Plug
SR-650-101-3E
Savi Fixed Reader SR-650-101,
Ethernet cable
92-250 VAC 50/60 Hz,
Japan Plug
SR-650-101-6E
Savi Fixed Reader SR-650-101,
Ethernet cable
92-250 VAC 50/60 Hz,
Type 2 Plug
SR-650-101-7E
Savi Fixed Reader SR-650-101,
Ethernet cable
92-250 VAC 50/60 Hz,
U.K. Plug
SR-650-101-8E
Savi Fixed Reader SR-650-101,
Ethernet cable
92-250 VAC 50/60 Hz,
China Plug
SR-650-101-9E
Savi Fixed Reader SR-650-101,
Ethernet cable
92-250 VAC 50/60 Hz,
Australian Plug
SR-650-101-DE
Savi Fixed Reader SR-650-101,
Ethernet cable
12 VDC, Pigtail wires
SR-650-101-TE
Savi Fixed Reader SR-650-101,
Ethernet cable
Solar DC Input, Transportable
Savi Fixed Reader SR-650-101 Installation Guide
Contacting Savi Global Support Services
Contacting Savi Global Support
Services
If you cannot find the information you need, contact Savi Global Support
Services.
Check www.savi.com/services/su.contact.shtml for contact information.
◆ Send email to help@savi.com.
◆ Call 1-888-994-7284 (North America only) or 650-316-4760 between
5 a.m. and 5 p.m. Pacific time.
When you contact Savi Global Support Services by telephone or email, have
the following information available:
◆
◆
◆
◆
◆
◆
Contact information (company name, your name, email, and phone
number)
Problem description
Product type
Software version
Serial number or license information
Savi Fixed Reader SR-650-101 Installation Guide
13
CHAPTER
14
Introduction
Savi Fixed Reader SR-650-101 Installation Guide
CHAPTER
Designating Locations
and Connecting Cables 2
Before physically installing the Savi Fixed Reader SR-650-101, you must:
1. Consult a site plan to determine the reader’s installation location.
2. Connect power cables and network cables.
3. Supply power.
Planning a Site
To plan a site you must conduct a site survey and plan the RFID network
configuration. Once the site plan is in place, refer to it to determine where
to install Savi fixed readers. Follow the directions in this manual to ensure
proper installation of each Savi Fixed Reader SR-650-101.
Connecting Power Cables to the
Savi Fixed Reader
Note: The Savi Fixed Reader SR-650-101 is rated for use in severe
environments. For additional precautions, Savi recommends the use
of heat shrink tubing (Savi part number 680-02423-001) for units subject
to outdoor use.
Before you connect the Savi fixed reader’s power cable, be sure to check
relevant configuration or wiring diagrams.
The power source can be 12 to 24 VDC or 92 to 250 VAC. The socketoutlet should be installed near the equipment and should be easily
accessible. The Savi Fixed Reader SR-650-101 does not require adjustment
or modification for different power sources. The appropriate power cable is
supplied based on the requirements specified when the order was placed.
Savi Fixed Reader SR-650-101 Installation Guide
15
CHAPTER
Designating Locations and Connecting Cables
You can also power the Savi Fixed Reader SR-650-101 from a Savi Solar
Power Module or by vehicle power. A fixed-length, molded cable is
supplied with the Solar Power Module. You can purchase the Vehicle
Power Cable as an accessory.
To connect the power cable to the reader:
1. If you are installing the Savi Fixed Reader SR-650-101 in an outdoor
location, slide heat shrink tubing onto the power cable before connecting
the cable to the reader.
2. On the Savi fixed reader, plug the cable’s female connector into the
power input socket. See Figure 2-1.
a. Turn the connector to align its notch on the side nearest the Savi
fixed reader’s dome.
b. Firmly push the locking ring forward and rotate it clockwise to lock
the connector.
Figure 2-1 Power connector
Connector
panel
Insert the female connector
of the power cable into the
power input
16
Savi Fixed Reader SR-650-101 Installation Guide
Connecting Power Cables to the Savi Fixed Reader
Figure 2-2 Power cable
Connector shell
Plug to AC outlet
3. Ensure that the heat shrink tubing is protecting the power cable’s
connector shell.
Position the heat shrink tubing so it is not completely against the
reader’s connector panel and covering the entire connector shell but
is .25 of an inch (6.35 mm) from the connector panel.
4. Apply heat to the heat shrink tubing to contract and bind the protective
covering to the power cable and its connector shell.
For detailed instructions regarding application of the heat shrink tubing,
follow the procedures in Appendix B.
Warning: To avoid static electricity shock, connect the network
cables before applying power to the Savi fixed reader. Complete
“Connecting the Network Cables” on page 18, and then proceed
to “Applying Power to the Savi Fixed Reader” on page 25.
Savi Fixed Reader SR-650-101 Installation Guide
17
CHAPTER
Designating Locations and Connecting Cables
Connecting the Network Cables
Before you connect the Savi fixed reader’s network cables, check relevant
configuration or wiring diagrams.
Note: The Savi Fixed Reader SR-650-101 is rated for use in severe
environments. For additional precautions, Savi recommends the use of
heat shrink tubing (Savi part number 680-02423-001) for units subject
to outdoor use.
You can connect the Savi fixed reader using two types of network
protocols:
◆
SaviNet connection (RS-485)
◆
Ethernet via RJ-45 connector; 10Base-T
SaviNet Connection (RS-485)
SaviNet requires an 8-foot (2.4 meters) network cable with an RS-485 to
RS-232 converter on one end and an RS-485 connector on the other end
to connect the Savi Fixed Reader SR-650-101 to the host computer.
With a SaviNet connection, you can:
◆
Connect one reader directly to a host computer
◆
Attach multiple readers in a daisy chain pattern
Connecting to the Host Computer
To directly connect the Savi Fixed Reader SR-650-101 to the host computer
using the RS-485 port:
1. If you are installing the Savi fixed reader in an outdoor location, slide
heat shrink tubing onto the network cable before connecting the cable to
the reader.
For detailed instructions regarding application of the heat shrink tubing,
follow the procedures in Appendix B.
2. Plug the SaviNet cable’s RS-485 female connector into the
NETWORK IN port on the Savi fixed reader. Ensure that the notch is
correctly aligned. See Figure 2-3.
18
Savi Fixed Reader SR-650-101 Installation Guide
Connecting the Network Cables
Note: The SaviNet cable with converter is provided with Savi
software (such as Savi Retriever) since only one computerconnector cable is required per network. The SaviNet cable is
also available separately (Savi part number 830-00911-001).
Figure 2-3 RS-485 ports
Network In
(RS-485 port)
Network Out
(RS-485 port)
3. Push the locking ring forward firmly and rotate clockwise to lock
the connector.
4. Connect the RS-232 converter end of the cable to the host computer’s
RS-232 port.
Savi Fixed Reader SR-650-101 Installation Guide
19
CHAPTER
Designating Locations and Connecting Cables
Connecting Two or More Savi Fixed Readers
If you are connecting several Savi fixed readers in a daisy chain
configuration, use a standard Savi-provided network cable to connect each
reader, as shown in Figure 2-4.
Figure 2-4 Savi fixed readers in daisy chain configuration
Network Out
Network In
Network Out
Network In
Network Out
Network In
To Host
Computer
Network In
Network Out
To connect the multiple Savi fixed readers:
1. If you are installing the Savi fixed reader in an outdoor location, slide
heat shrink tubing onto the network cables before connecting the cables
to the reader.
For detailed instructions regarding application of the heat shrink tubing,
follow the procedures in Appendix B.
2. Connect the first cable’s female connector (cable 1 in Figure 2-4) to
the NETWORK IN port on the Savi fixed reader.
The other end of this cable connection connects to the host computer.
3. Using a second, unconnected cable (cable 2 in Figure 2-4), plug the
cable’s male connector into the NETWORK OUT port on the
Savi fixed reader.
4. Connect the female connector end of the second network cable
(cable 2 in Figure 2-4) to the next reader’s NETWORK IN port.
20
Savi Fixed Reader SR-650-101 Installation Guide
Connecting the Network Cables
5. Continue to link new readers as necessary (cables 3 and 4 in Figure 2-4).
The final reader in the chain must be terminated with a matched resistive
load (termination cable assembly) to prevent signal reflections in long
cable runs.
Note: The termination cable assembly (Savi part number
830-04598-001) is included with the reader. If the distance
between readers is greater than 100 feet (30.48 meters),
additional network cables are available (Savi part number
830-00169-100). A cable adapter (Savi part number
625-00921-001) is included to connect two cables.
Ethernet Connection
You can connect the Savi Fixed Reader SR-650-101 directly to a network
hub via the built-in Ethernet connection. The readers are the source of RFID
tag read and service events. SmartChain Site Manager records, stores, and
forwards these events to Savi SmartChain. SmartChain Site Manager also
sends commands for reader management or control logic. The readers
communicate with SmartChain Site Manager using UDAP.
SmartChain Site Manager and SmartChain are available separately from
Savi Technology.
Savi Fixed Reader SR-650-101 Installation Guide
21
CHAPTER
Designating Locations and Connecting Cables
To connect the Savi Fixed Reader SR-650-101 to an Ethernet hub:
1. Connect an RJ-45 connector to the Ethernet cable.
The other end of the Ethernet cable includes an RJ-45 connector with a
protective connector shell.
Figure 2-5 Ethernet cable and RJ-45 connector
RJ-45 connector with
connector shell
22
RJ-45 connectors
Cable
Savi Fixed Reader SR-650-101 Installation Guide
Connecting the Network Cables
2. Cover the RJ-45 connector with an RJ-45 sleeve. Connect this end of the
Ethernet cable to the Ethernet hub.
Figure 2-6 RJ-45 connector and sleeve
3. Remove the protective cap from the Ethernet port on the Savi Fixed
Reader SR-650-101.
Figure 2-7 Ethernet port
Ethernet port
Savi Fixed Reader SR-650-101 Installation Guide
23
CHAPTER
Designating Locations and Connecting Cables
4. Connect the RJ-45 connector with the connector shell into the Ethernet
port.
Figure 2-8 Connected Savi Fixed Reader SR-650-101
Note: Replace and tighten the protective cap when the Ethernet port is
not used.
24
Savi Fixed Reader SR-650-101 Installation Guide
Applying Power to the Savi Fixed Reader
Applying Power to the Savi Fixed
Reader
After connecting power and network cables, apply power to the reader by
connecting the male connector end of the power cable to the appropriate
power source, such as the Savi Solar Power Module or an AC outlet.
Figure 2-9 Savi Fixed Reader SR-650-101 LED display panel
LED display
panel
To confirm that power is present in the reader:
1. Observe the indicators on the LED display panel. The power indicator
should be illuminated whenever power is present.
a. During the initial power-on sequence, the Savi fixed reader
concurrently displays a dot and a dash.
b. After this initial display, the reader identification number (ID)
appears in the LED display as a sequence of five digits.
Savi fixed reader ID number 01234 displays: 0, then 1, then 2, then 3,
and then 4 in sequence during the initialization process.
Savi Fixed Reader SR-650-101 Installation Guide
25
CHAPTER
Designating Locations and Connecting Cables
c. After the ID display, the reader’s default IP address appears in the
LED display.
Savi fixed reader IP address 10.7.19.11 displays: IP, then =, then 10,
then 7, then 19, and then 11 in sequence.
Note: Upon changing the reader’s default IP address, the reader’s
new IP address appears in the LED display. To change the reader’s
IP address, see “Adding and Configuring the Reader in SmartChain
Site Manager” on page 29.
d. The final state of the indicator displays a dot and a blinking dash.
2. If at any time you are not sure that the Savi fixed reader is operating
properly, reset the reader by disconnecting and then reconnecting the
power source.
After resetting the Savi Fixed Reader SR-650-101, it should repeat the
power-on sequence described above.
The Savi fixed reader is now ready for you to verify communication
functions.
Note: The Savi Fixed Reader SR-650-101 has a watchdog sensor
that automatically resets the reader if power fluctuations or other
interruptions occur that might affect the reader’s performance.
26
Savi Fixed Reader SR-650-101 Installation Guide
CHAPTER
Managing the Reader
Network
The Savi Fixed Reader SR-650-101 communicates with the SmartChain
Site Manager host computer, using the SaviNet (RS-485) or Ethernet
protocols. When the reader communicates with the Savi Retriever host
computer, only the SaviNet (RS-485) protocol is required.
This chapter provides the information you need to manage and configure
your Savi Fixed Reader SR-650-101 with the appropriate host computer.
It includes information about:
◆
Identifying readers in SmartChain Site Manager using the reader’s
unique device number or serial number
◆
Adding and configuring readers for Ethernet and SaviNet (RS-485)
connections with SmartChain Site Manager
◆
Configuring readers for SaviNet (RS-485) connection with
Savi Retriever
Savi Fixed Reader SR-650-101 Installation Guide
27

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2008:09:19 11:22:33-07:00
Create Date                     : 2008:09:19 11:22:21-07:00
Metadata Date                   : 2008:09:19 11:22:33-07:00
Creator Tool                    : FrameMaker 8.0
Format                          : application/pdf
Title                           : EchoPointSR650-101.book
Creator                         : mconde
Document ID                     : uuid:69bcf855-84a7-4955-a5f8-e0bde9fe3c9a
Instance ID                     : uuid:775b71e6-4e69-4bd4-a173-f2e6d313e637
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Page Count                      : 29
Author                          : mconde
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KL7-650R-V2

Navigation menu