Snap One C4APDKD ADAPTIVE PHASE DIMMER/KEYPAD DIMMER User Manual

Control4 ADAPTIVE PHASE DIMMER/KEYPAD DIMMER

a href="https://usermanual.wiki/Snap-One" itemprop="url"> Snap One >

USER MANUAL

™Minimum Load (with neutral) All load types 1WMinimum Load (without neutral) Incandescent (Tungsten) 7W Halogen 7W Fluorescent* N/A Compact Fluorescent (CFL)* N/A LED* N/AEnvironmentalOperational Temperature 32˚ F - 104˚ F  (0˚ C - 40˚ C)All load ratings are based on an ambient  temperature of 25˚ C.Humidity 5% to 95% non-condensingStorage -4˚ F - 158˚ F  (-20˚ C - 70˚ C)MiscellaneousControl Communications ZigBee, IEEE 802.15.4, 2.4 GHz, 15-channel spread spectrum radioWallbox Volume 5.75 cubic inchesWeight 0.12 lb. (0.05 kg)Shipping Weight 0.18 lb. (0.08 kg)* NOTES: (1) The maximum load requirements for fluorescent, CFL and LED loads can vary greatly depending upon the specific fixture and/or bulb being used. These load types have significant in-rush current which can trip the protection circuitry on the device. (2) The quality and performance of these load types varies greatly from manufacturer to manufacturer. When using these load types, we recommend testing in advance. If problems are found, simply changing to a dierent bulb manufacturer may solve the problem.(3) Additionally, we do not recommend the use of fluorescent, CFL, or LED loads without a neutral wire connected to the dimmer due to the capacitive nature of these load types.Warnings and ConsiderationsWARNING! Turn OFF electrical power before installing or servicing this product. Improper use or installation can cause SERIOUS INJURY, DEATH or LOSS/DAMAGE OF PROPERTY.ATTENTION! Coupez l’alimentation électrique avant d’installer ou de réparer ce produit. Une mauvaise installation ou utilisation peut entraîner des blessures graves, décès ou perte / dommages à la propriété.WARNING! This device must be protected by a circuit breaker (20A max).ATTENTION! Cet appareil doit être protégé par un disjoncteur (20A max.)WARNING! Ground this device in accordance with the National Electric Code (NEC) requirements. DO NOT rely solely upon the yoke plate’s contact with a metal wallbox for adequate grounding. Use the device’s ground wire to make a secure connection to the safety ground of the electrical system.ATTENTION! Cet appareil doit être en conformité avec le Code national de l’électricité (NEC). Ne comptez pas uniquement au contact de la plaque avant avec un boîtier mural métallique pour la mise à la terre adéquate. Utilisez cet appareil à la terre de l’appareil pour établir une connexion sécurisée au système électrique.IMPORTANT! This device must be installed by a licensed electrician in accordance with all national and local electrical codes.IMPORTANT! If you are unsure about any part of these instructions, consult a qualified electrician.Supported Models• C4-APD120  Adaptive Phase Dimmer, 120V• C4-APD277  Adaptive Phase Dimmer, 277VIntroductionThe Control4® Adaptive Phase Dimmer operates independently or as part of a Control4 home automation system. It installs in a standard back box using typical wiring standards and communicates to the Control4 system using a wireless connection.Box Contents• Adaptive Phase Dimmer• Wire Nuts• Warranty Card• AdaptivePhaseDimmerInstallationGuide (this document)Specifications and Supported Load TypesThe specifications are described below.Model Numbers C4-APD120-xx, C4-APD277-xxPower Requirements C4-APD120: 120VAC +/-10%, 50/60Hz C4-APD277: 277VAC +/-10%, 50/60HzThis device can function with or without a neutral AC connection depending on load type. See load types and “Sample Wiring Configurations” below.Power Consumption C4-APD120: 450mW; C4-APD277: 550mWLoad Types and RatingsSupported Load Types Incandescent; Halogen; Electronic (Solid State) Low Voltage (ELV) transformers, Magnetic (Iron Core, Inductive) Low Voltage (MLV) transformers; Phase-Dimmable Fluorescents, Compact Fluorescents, and LEDs.C4-APD120 Maximum Load 1 Gang 2 Gang 3+ GangIncandescent (Tungsten) 600W 550W 500WHalogen 600W 550W 500WFluorescent* 300W 300W 300WCompact Fluorescent (CFL)* 300W 300W 300WLED* 120W 120W 120WC4-APD277 Maximum Load 1 Gang 2 Gang 3+ GangIncandescent (Tungsten) 1000 900 800Halogen 1000 900 800Fluorescent* 500 500 500Compact Fluorescent (CFL)* 500 500 500LED* 200 200 200Adaptive Phase Dimmer  Installation GuideIMPORTANT! Use this device only with copper or copper-clad wire. Do not use aluminum wiring. This product has not been approved for use with aluminum wiring.IMPORTANT! To reduce the risk of overheating and possible damage to other equipment, do not install to control a receptacle or a motor operated appliance.IMPORTANT! This product generates heat during normal operation.IMPORTANT! Using this product in a manner other than outlined in this document voids your warranty. Further, Control4 is NOT liable for any damage incurred with the misuse of this product. See “Troubleshooting.”IMPORTANT! Do NOT use a power screwdriver to install this device. If you do, you may overtighten the screws and strip them. Also, overtightening the screws may interfere with proper button operation.IMPORTANT! This is an electronic device with intricate components. Handle and install with care!Installation Instructions1  Ensure that the location and intended use meet the following criteria:• Do not exceed the load capacity requirements of the dimmer. In multi-gang installations, a reduction of the dimmers’ capacity is required to allow the dimmers to be installed side-by-side. Refer to the load ratings in the specifications above for details.• Install in accordance with all national and local electrical codes.• The range and performance of the wireless control system is highly dependent on the following: (1) distance between devices; (2) layout of the home; (3) walls separating devices; and (4) electrical equipment located near devices.2  If installing in a multi-gang scenario, use pliers to remove the inner-side breakaway tabs. Bend each tab forward first, and then back and forth until it breaks o. Remove the inner-side tabs ONLY on any device side that will be adjacent to another device. DO NOT remove tabs on any side that will become the outer side of a group of devices. Handle the device with care after removing the tabs, as the broken edge can be sharp.3  Turn o the local electrical power by either switching o the circuit breaker or removing the fuse from the fuse box. To ensure the wires do NOT have power running to them, use an inductive voltage detector.NOTE: The back box wiring shown in this document is an example. Your wire colors and functions may dier. If you are not sure which wires are the Hot, Neutral, Load, Traveler, and Ground wires, have a trained electrician perform the installation.4  Prepare each wire. Wire insulation should be stripped back 5/8 of an inch from the wire end (see Figure 1).Figure 1.  Strip Wire Insulation5  Identify your wiring application, and then see the appropriate wiring diagram in the “Sample Wiring Configurations” section below.IMPORTANT! Not grounding this product, as described in the “Warnings and Considerations” section, may result in an installation less immune to damage caused by electrical disturbances, such as ESD or lightning, and may void the warranty.6  Identify and connect the dimmer wires to the back box wires using the wire nuts.IMPORTANT!  The yellow wire is not a traditional traveler. It cannot directly power a lighting load. It must be used only to connect to a Control4 Auxiliary Keypad. See “Sample Wiring Configurations.”TIP:  If you are using a Control4 push-on (screwless) faceplate in a multi-gang installation, attach the black faceplate subplate to all of the devices that will be installed into the back box prior to attaching the devices to the back box. This will help ensure that all the devices are properly aligned and on the same plane after installation.7  Fit the wires into the back box. Bend the wires in a zigzag pattern so that they easily fold into the back box (Figure 2).Figure 2.  Bend the Wires8  Align the dimmer to the back box (the load rating label should be at the bottom) and fasten it with screws. Tighten the screws until the back side of the yoke plate is even with the wall surface, but no further. Overtightening can warp the dimmer and cause mechanical malfunction.9  Install the Control4 Faceplate following the instructions in the Faceplate Installation Guide or attach a standard Decora-style faceplate.10  Turn ON power at the circuit breaker or replace the fuse                             from the fuse box.Operation and ConfigurationOn initial power up, all status LEDs on the dimmer will illuminate green, indicating that the device has power. To set up this dimmer for use with a Control4 system, refer to the Composer Pro User Guide. To operate this dimmer as a stand-alone device:• Click the top button to turn the light on.• Click the bottom button to turn the light o.• Press and hold the top button to ramp the light up. Release the button at the desired light level.• Press and hold the bottom button to fade the light down. Release the button at the desired light level.Air Gap SwitchDuring routine lamp replacement, remove power from the lamp by engaging the air gap mechanism. 1  To engage, press on the right side of the top actuator bar until the left side pops out. All LEDs on the dimmer will turn o, and the dimmer will no longer control the light when the air gap mechanism has been engaged. 2  To return power to the dimmer and lamp, press on the left side of the top actuator bar until it snaps back into place.
™Figure 3. Dimmer with Actuator BarButton Tap SequencesThe button tap sequences are defined in the table below. Button tap sequences that require a single (1) button should use the top button.Function Button SequenceIdentify 4ZigBee Channel 7Reboot 15Factory Reset 9-4-9Leave Mesh and Reset 13-4-13TroubleshootingIf the light does not turn on:• Ensure that at least one (1) LED on the face of the dimmer is lit.• Ensure that the light bulb is not burned out and is screwed in tightly.• Ensure that the circuit breaker is not turned OFF or tripped.• Check for proper wiring (see “Sample Wiring Configurations”). • For help on the installation or operation of this product, email or call the Control4 Technical Support Center. Please provide your exact model number. Contact support@control4.com or see the web site www.control4.com.Care and Cleaning• Do NOT paint the dimmer or its wall plate.• Do NOT use any chemical cleaners to clean the dimmer.• Clean surface of the dimmer with a soft damp cloth as needed.Regulatory/Safety Information  To review Regulatory information for your particular Control4 products, see the information located on the Control4 website at: http://www.control4.com/regulatory/.Patent InformationApplicable patents are available at http://www.control4.com/legal/patents.WarrantyFor complete warranty information, including details on consumer legal rights as well as warranty exclusions, review the Warranty card or visit www.control4.com/warranty.Figure 6. Multiple Device Location Using Auxiliary Keypad, With Neutral ConnectionFigure 7. Multiple Device Location with Auxiliary Keypad, Without Neutral ConnectionFigure 8. Multiple Device Location Using Configurable Keypad, Neutral RequiredCopyright ©2013 Control4. . All rights reserved. Control4, the Control4 logo, the Control4 iQ logo and the Control4 certified logo are registered trademarks or trademarks of Control4 Corporation in the United States and/or other countries. All other names and brands may be claimed as the property of their respective owners Pricing and specifications are subject to change without notice About this DocumentPart Number: 200-00306 Rev A,  2/15/2013Sample Wiring ConfigurationsFigure 4. Single Device Location, With Neutral ConnectionFigure 5. Single Device Location, Without Neutral ConnectionActuator Bar
™Minimum Load (with neutral) All load types 1WMinimum Load (without neutral) Incandescent (Tungsten) 7W Halogen 7W Fluorescent* N/A Compact Fluorescent (CFL)* N/A LED* N/AEnvironmentalOperational Temperature 32˚ F - 104˚ F  (0˚ C - 40˚ C)All load ratings are based on an ambient  temperature of 25˚ C.Humidity 5% to 95% non-condensingStorage -4˚ F - 158˚ F  (-20˚ C - 70˚ C)MiscellaneousControl Communications ZigBee, IEEE 802.15.4, 2.4 GHz, 15-channel spread spectrum radioWallbox Volume 5.75 cubic inchesWeight 0.12 lb. (0.05 kg)Shipping Weight 0.22 lb. (0.10 kg)* NOTES: (1) The maximum load requirements for fluorescent, CFL and LED loads can vary greatly depending upon the specific fixture and/or bulb being used. These load types have significant in-rush current which can trip the protection circuitry on the device. (2) The quality and performance of these load types varies greatly from manufacturer to manufacturer. When using these load types, we recommend testing in advance. If problems are found, simply changing to a dierent bulb manufacturer may solve the problem.(3) Additionally, we do not recommend the use of fluorescent, CFL, or LED loads without a neutral wire connected to the dimmer due to the capacitive nature of these load types.Warnings and ConsiderationsWARNING! Turn OFF electrical power before installing or servicing this product. Improper use or installation can cause SERIOUS INJURY, DEATH or LOSS/DAMAGE OF PROPERTY.ATTENTION! Coupez l’alimentation électrique avant d’installer ou de réparer ce produit. Une mauvaise installation ou utilisation peut entraîner des blessures graves, décès ou perte / dommages à la propriété.WARNING! This device must be protected by a circuit breaker (20A max).ATTENTION! Cet appareil doit être protégé par un disjoncteur (20A max.)WARNING! Ground this device in accordance with the National Electric Code (NEC) requirements. DO NOT rely solely upon the yoke plate’s contact with a metal wallbox for adequate grounding. Use the device’s ground wire to make a secure connection to the safety ground of the electrical system.ATTENTION! Cet appareil doit être en conformité avec le Code national de l’électricité (NEC). Ne comptez pas uniquement au contact de la plaque avant avec un boîtier mural métallique pour la mise à la terre adéquate. Utilisez cet appareil à la terre de l’appareil pour établir une connexion sécurisée au système électrique.IMPORTANT! This device must be installed by a licensed electrician in accordance with all national and local electrical codes.IMPORTANT! If you are unsure about any part of these instructions, consult a qualified electrician.Supported Models• C4-KD120  Keypad Dimmer, 120V• C4-KD277  Keypad Dimmer, 277VIntroductionThe Control4® Keypad Dimmer operates independently or as part of a Control4 home automation system. It installs in a standard back box using typical wiring standards and communicates to the Control4 system using a wireless connection.Box Contents• Keypad Dimmer• Wire Nuts• Warranty Card• KeypadDimmerInstallationGuide (this document)• KeypadButtonInstallationGuideSpecifications and Supported Load TypesThe specifications are described below.Model Numbers C4-KD120-xx, C4-KD277-xxPower Requirements C4-KD120: 120VAC +/-10%, 50/60Hz C4-KD277: 277VAC +/-10%, 50/60HzThis device can function with or without a neutral AC connection depending on load type. See load types and “Sample Wiring Configurations” below.Power Consumption C4-KD120: 450mW; C4-KD277: 550mWLoad Types and RatingsSupported Load Types Incandescent; Halogen; Electronic (Solid State) Low Voltage (ELV) transformers, Magnetic (Iron Core, Inductive) Low Voltage (MLV) transformers; Phase-Dimmable Fluorescents, Compact Fluorescents, and LEDs.C4-KD120 Maximum Load 1 Gang 2 Gang 3+ GangIncandescent (Tungsten) 600W 550W 500WHalogen 600W 550W 500WFluorescent* 300W 300W 300WCompact Fluorescent (CFL)* 300W 300W 300WLED* 120W 120W 120WC4-KD277 Maximum Load 1 Gang 2 Gang 3+ GangIncandescent (Tungsten) 1000 900 800Halogen 1000 900 800Fluorescent* 500 500 500Compact Fluorescent (CFL)* 500 500 500LED* 200 200 200Keypad Dimmer  Installation GuideIMPORTANT! Use this device only with copper or copper-clad wire. Do not use aluminum wiring. This product has not been approved for use with aluminum wiring.IMPORTANT! To reduce the risk of overheating and possible damage to other equipment, do not install to control a receptacle or a motor operated appliance.IMPORTANT! This product generates heat during normal operation.IMPORTANT! Using this product in a manner other than outlined in this document voids your warranty. Further, Control4 is NOT liable for any damage incurred with the misuse of this product. See “Troubleshooting.”IMPORTANT! Do NOT use a power screwdriver to install this device. If you do, you may overtighten the screws and strip them. Also, overtightening the screws may interfere with proper button operation.IMPORTANT! This is an electronic device with intricate components. Handle and install with care!Installation Instructions1  Ensure that the location and intended use meet the following criteria:• Do not exceed the load capacity requirements of the dimmer. In multi-gang installations, a reduction of the dimmers’ capacity is required to allow the dimmers to be installed side-by-side. Refer to the load ratings in the specifications above for details.• Install in accordance with all national and local electrical codes.• The range and performance of the wireless control system is highly dependent on the following: (1) distance between devices; (2) layout of the home; (3) walls separating devices; and (4) electrical equipment located near devices.2  If installing in a multi-gang scenario, use pliers to remove the inner-side breakaway tabs. Bend each tab forward first, and then back and forth until it breaks o. Remove the inner-side tabs ONLY on any device side that will be adjacent to another device. DO NOT remove tabs on any side that will become the outer side of a group of devices. Handle the device with care after removing the tabs, as the broken edge can be sharp.3  Turn o the local electrical power by either switching o the circuit breaker or removing the fuse from the fuse box. To ensure the wires do NOT have power running to them, use an inductive voltage detector.NOTE: The back box wiring shown in this document is an example. Your wire colors and functions may dier. If you are not sure which wires are the Hot, Neutral, Load, Traveler, and Ground wires, have a trained electrician perform the installation.4  Prepare each wire. Wire insulation should be stripped back 5/8 of an inch from the wire end (see Figure 1).Figure 1.  Strip Wire Insulation5  Identify your wiring application, and then see the appropriate wiring diagram in the “Sample Wiring Configurations” section below.IMPORTANT! Not grounding this product, as described in the “Warnings and Considerations” section, may result in an installation less immune to damage caused by electrical disturbances, such as ESD or lightning, and may void the warranty.6  Identify and connect the dimmer wires to the back box wires using the wire nuts.IMPORTANT!  The yellow wire is not a traditional traveler. It cannot directly power a lighting load. It must be used only to connect to a Control4 Auxiliary Keypad. See “Sample Wiring Configurations.”TIP:  If you are using a Control4 push-on (screwless) faceplate in a multi-gang installation, attach the black faceplate subplate to all of the devices that will be installed into the back box prior to attaching the devices to the back box. This will help ensure that all the devices are properly aligned and on the same plane after installation.7  Fit the wires back into the back box. Bend the wires in a zigzag pattern so that they easily fold into the back box (Figure 2).Figure 2.  Bend the Wires8  Align the dimmer to the back box (the load rating label should be at the bottom) and fasten it with screws. Tighten the screws until the back side of the yoke plate is even with the wall surface, but no further. Overtightening can warp the dimmer and cause mechanical malfunction.9  Install the Control4 Faceplate following the instructions in the FaceplateInstallationGuideor attach a standard Decora-style faceplate.10  Attach the buttons, actuator bar, and sensor bar as described in the KeypadButtonInstallationGuide.11  Turn ON power at the circuit breaker or replace the fuse                             from the fuse box.Operation and ConfigurationOn initial power up, all status LEDs on the dimmer will illuminate green indicating that the device has power. To set up this dimmer for use with a Control4 system, refer to the ComposerProUserGuide. To operate this dimmer as a stand-alone device prior to configuration in Composer Pro:• If the light is o, click any button to turn the light on.• If the light is on, click any button to turn the light o.• Press and hold any button to ramp the light up/down. Release the button at the desired light level.• If the split up/down buttons have been installed in the bottom button slot, the up and down arrows will ramp and fade the light respectively.
Download:
Mirror Download [FCC.gov]
Document ID1968590
Application IDs2j28XyO3JmmihvcpuhaHg==
Document DescriptionUSER MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize297.12kB (3714044 bits)
Date Submitted2013-05-20 00:00:00
Date Available2013-05-20 00:00:00
Creation Date2017-10-27 11:12:16
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-10-27 11:12:16
Document TitleUSER MANUAL
Document CreatorAdobe InDesign CS6 (Macintosh)
FCC ID Filing: R33C4APDKD

Navigation menu