Trane US CONT8245 COLOR WIFI Z-WAVE THERMOSTAT User Manual part 1

Trane US, Inc. COLOR WIFI Z-WAVE THERMOSTAT part 1

Contents

User manual part 1

Download: Trane US CONT8245 COLOR WIFI Z-WAVE THERMOSTAT User Manual part 1
Mirror Download [FCC.gov]Trane US CONT8245 COLOR WIFI Z-WAVE THERMOSTAT User Manual part 1
Document ID3987320
Application ID5Z8YjecBErmjevCqFq1RnQ==
Document DescriptionUser manual part 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize286.42kB (3580298 bits)
Date Submitted2018-09-01 00:00:00
Date Available2018-09-01 00:00:00
Creation Date2018-05-03 15:34:30
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2018-08-27 14:03:29
Document TitleUser manual part 1
Document CreatorAdobe InDesign CC 13.0 (Windows)

American Standard Gold 824
Smart Control User Guide
The Gold 824 is an easy-touse, programmable control
with a color touch-screen.
When connected with
Nexia™ smart home, you can
control your home’s heating
and cooling system and
up to 230 separate Z-Wave
devices from a smart phone,
PC or tablet from virtually
anywhere.
This guide will help you
configure and connect your
Gold 824 Smart Control
quickly and easily.
Start using your
new Gold 824
now! See “Start
Here!” on page
3.
012-5060-05
Congratulations!
Thank you for choosing the American Standard
Gold 824 Smart Control. The intuitive interface
and powerful features incorporated into the
compact design of the color touch-screen control
represent the latest in climate control technology
from the industry’s leader in residential HVAC
systems.
This guide will introduce you to the unit’s many
features and get you started using your Gold 824
Smart Control right away.
The Gold 824 Smart Control can be accessed
remotely with your smart device and it can serve
as the central hub of an entire network of smart
home devices. To fully enjoy these benefits your
Gold 824 must be connected to the Nexia™
platform. Nexia provides an all-in-one cloud
based app that allows you to access your Gold
824 anytime/anywhere connecting your smart
devices through Z-Wave technology. See the full
line of available features and functions at:
http://www.nexiahome.com/
For tutorials search: Gold 824.
page 2
Nexia™ smart home allows you to:
• Monitor and control your HVAC system
using an internet-enabled smart phone,
tablet or computer from anywhere in the
world.
• Build a network of up to 230 Z-Wave
enabled products on one account.
• View weather information including
outdoor temperature, five-day forecasts,
radar and weather alerts.
• Receive text and e-mail notifications that
inform you of happenings in your home.
• Receive software updates automatically.
Up to four smart controls of any combination of the
1050, 850, Gold 824 and 624 are allowed on your Nexia™
smart home account for no additional cost. A monthly
subscription charge may apply beyond this number of
devices.
Contents
User Setup Wizard.................................................... 3
Navigating the Control.......................................... 4
Temperature Control Panel.................................. 7
Adding Widgets........................................................ 8
Home Screen Customization............................... 9
Menu Screen............................................................10
Settings Screen.......................................................11
Scheduling...............................................................12
Changing Periods...................................................14
Adding Periods.......................................................15
Deleting Periods.....................................................16
Overriding Schedules...........................................17
Configuring 1-Touch Presets..............................18
Setting Access Restrictions.................................20
Nexia™ smart home..............................................21
Network Setup........................................................22
Nexia™ Registration...............................................24
Adding/Removing Z-Wave Devices (via
XL824)........................................................................27
Adding Z-Wave Devices (via mobile app).....28
Advanced Z-Wave Settings.................................29
Other Features........................................................31
Notices.......................................................................32
FCC Notice................................................................32
ICC NOTICE...............................................................32
824 User Guide
Start Here!
The User Setup
Wizard guides
you through the
Gold 824’s User
configurable
settings.
To complete the Setup Wizard and connect the
Gold 824 to Nexia™ smart home, you need:
• A high-speed connection to the Internet
(wired or wireless)
• Your wireless (WiFi) network name and
password
• An internet browser
• A valid e-mail address
Accessing the User Setup Wizard
Menu
Settings
To access the User Setup Wizard, press
MENU > SETTINGS > USER SETUP WIZARD.
When the Setup Wizard is activated, the process
cannot be cancelled. The Wizard will guide you
through the following steps:
012-5060-05
Screen Settings
• Adjust the Screen brightness, backlight,
screen saver and color themes.
Schedule Settings
• Set the Gold 824 scheduling feature to
enabled or disabled. When Scheduling is
disabled, 1-Touch Presets are available.
Guided Scheduling (Scheduling Enabled)
• Automatically create schedules based on
answers to a series of questions.
1-Touch Presets (Scheduling Disabled)
• Configure heating and cooling target
temperatures for Home, Away and Sleep
conditions. The Presets are selectable from
the Home Screen.
Network Setup
• Select your wireless network and enter
your password. If your wireless network is
available but not shown in the list, select
Hidden Network, and manually enter your
network’s name (SSID).
User Setup Wizard
com/as for help.
Nexia™ smart home Registration (requires
Internet connection)
• Your Gold 824 control comes equipped
with remote access and other features from
Nexia™ smart home.
Weather (requires Nexia registration)
• Input the Zip Code of the location for
appropriate weather information including
five-day forecasts, radar display and
weather alerts.
That’s it! You can now begin enjoying the
benefits of your new American Standard Gold
824 Smart Control!
NOTE: Wireless Setup is not required when the
Gold 824 is hard-wired to your home network.
NOTE: If you are having difficulty enrolling
the Gold 824 to your account, visit the
troubleshooting section on www.nexiahome.
page 3
Navigating the Control
page 4
Home Screen - Simple View
Default Home Screen can be customized with several
widgets. To learn more about this feature see the
section in this user guide about customization.
824 User Guide
Home Screen View
Homeowners may toggle between Home Screen Options
by pressing: Home Screen > Menu > Settings > Home
View Options. Select Simple View or Classic View.
NOTE: Simple View is the default view.
Simple View
OR
Classic View
012-5060-05
page 5
Home Screen - Classic View
page 6
Home Screen can be customized with several widgets. To learn more
about this feature see the section in this user guide about customization.
824 User Guide
Temperature Control Panel
The Temperature Control Panel is where target
temperatures are manually set and adjusted.
The panel is shown on the Classic View Home
Screen only.
Available when
Scheduling is Enabled
Press to disable
Schedule and
maintain current
temperature
settings.
Temporarily
overrides
Schedule
Touch Heating and Cooling Set-points to
show panel.
View and edit
Schedule
Hold
Perm
Hold
Until
Available when
Scheduling is Disabled
Press Away, Home or
Sleep to activate
1-Touch Presets
Away
Cooling Set Point
(press to change)
82º
OR
Mode
Indicator
Home
62º
Show
Schedule
Sleep
Schedule Status Area
012-5060-05
Press to
increase
the
set point
Press to
decrease
the
set point
Heating Set
Point (press to change)
page 7
Adding Widgets
Optionally, up to 2 widgets may be chosen to appear on
your home screen. They can be selected by navigating to
Menu > Settings > Screen > Screen Layout
When scheduling is
enabled, the Preset
button is disabled
and a Permanent
Hold button is
displayed. The
system will follow
the custom schedule
you’ve created. You
may override the
schedule by adjusting the temperature
settings with the
up/down arrows at
the right of the
screen. At the next
period change, the
schedule will resume.
To maintain a temperature indefinitely, adjust the setpoint to the desired temperature
and press the Permanent Hold button. It will then display ON, and the control will
maintain that temperature setpoint until you manually change it. Press the Permanent
Hold button again to turn Permanent Hold OFF. The Control resumes following the
schedule.
page 8
824 User Guide
Homeowners may customize the Home Screen by pressing:
Menu > Settings > Screen > Screen Layout
Home Screen Customization
Choose up to two widgets to show up on the Home Screen. Make
selection and press Apply.
012-5060-05
page 9
Menu Screen
page 10
Navigate to Menu Screen by pressing: Home Screen > Menu
824 User Guide
Navigate to Settings Screen by pressing: Home Screen > Menu > Settings
Press to modify screen
brightness, backlight timer,
screensaver, and color theme
Press to configure 1-Touch Presets
(if scheduling is enabled, Away
will be the only option)
Press to set
Temperature scale,
Deadband,
Calibration* and
Displayed Outdoor
Temperature
Sensor source
Push to set Time, Date,
and Daylight Savings
Manually set the
Date, Time and
Time Zone
Press to restart
the thermostat
Press to manually
upgrade sofware.
See Software
Upgrades for
more information.
Press to set system
maintenance and service
reminders
Settings Screen
Press to start the User
Setup Wizard
Press to add or remove devices
prior to Nexia registration
* Allow at least 1 hour for the Control to acclimate to the ambient room conditions. Temperature display may be inaccurate during the acclimation period.
012-5060-05
page 11
Scheduling
page 12
Schedule Screen
Navigate to Scheduling Screen by pressing: Home Screen > Menu > Schedules
824 User Guide
Navigate to Grouping Screen by pressing: Home Screen > Menu >
Schedules > Grouping
Grouping Screen
HINT: To copy a schedule between days, group them, press Apply, then open the grouping menu and de-select the days. Press Apply again.
012-5060-05
page 13
Changing Periods
To change Periods press: Home Screen > Menu > Schedules > Press Schedule time
Press to adjust
Start and End
Times
Changing Period Start or End Times
1. Press anywhere in the Period to make it
active. Other Periods will dim and the Start
and End times for this Period will be in a
black box.
2. Press the TIME START or TIME END and
adjust the time using the UP and DOWN
arrows. Note: The Gold 824 uses intelligent
technology and will not allow setting an
illogical start or end time. Periods must be
at least 30 minutes in duration.
Changing Period Set Points
1. Press the active Period’s Cooling or Heating
Set Point.
Schedule
6:00 am
Time
Start
Time
End
78º
Press in the red or blue area, then adjust
the Set Point using the up
and down arrows
Mon Tue Wed Thu Fri Sat Sun
8:00 am
6:00 pm
85º
Wake
Away
70º
62º
78º
10:00 pm
82º
Use the Up and
Down
ArrowsSleep
to
Home
change values
70º
62º
2. Adjust the Set Point using the UP or DOWN
arrows.
Changing the Period Name
Apply
1. Press the PERIOD NAME (Wake, Away, etc.).
2. Select a predefined name or press NEW and
select NEXT.
3. If selecting a new name, enter the name
using the on-screen keyboard.
4. Press NEXT.
page 14
Press Apply to save
changes and exit
Cancel
Press in the gray area
to rename the period
When all changes have been made, press APPLY
to save and exit, or press CANCEL to discard all
changes that were made to this Schedule.
824 User Guide
Navigate to add Periods by pressing: Home Screen > Menu > Schedules > Add Period
The Gold 824 Smart Control is capable of
adjusting the temperature settings throughout
the day according to a user-programmable
schedule.
Each day of the week can have its own unique
schedule, and each day can have a maximum of
four Periods.
Important: Scheduling must be enabled
before a schedule can be defined. To verify
that Scheduling is enabled, navigate to
MENU > SETTINGS > SCHEDULES and verify
that ENABLED is highlighted.
To set or modify schedules, navigate to HOME
> MENU > SCHEDULES or select SHOW
SCHEDULES from the Temperature Control
Panel.
Periods define the time of day when the target
temperature is adjusted. Each day can have from
1-4 Periods, and each day can have different
number of periods. The Scheduling Screen
shows the start time for each Period highlighted
across the top row.
Adding Periods
1. Press ADD PERIOD, the Add Period Screen
is displayed.
012-5060-05
2. Press the green circle where you would like
to insert a Period.
3. Choose a name for the new Period or select
New to define a custom name and press
NEXT.
4. If selecting a new name, enter the name
using the on-screen keyboard.
Adding Periods
5. Press NEXT.
6. Add additional periods, the maximum per
day is 4.
7. Press APPLY to save your changes and
return to the Schedule Screen. The new
period should be displayed.
Press the green target to insert a new period
Add Period
6:00 am
8:00 am
6:00 pm
10:00 pm
78º
85º
78º
82º
Wake
Away
Home
Sleep
70º
62º
70º
62º
Apply
Cancel
page 15

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2018:05:03 15:34:30-05:00
Creator                         : Adobe InDesign CC 13.0 (Windows)
Modify Date                     : 2018:08:27 14:03:29+08:00
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08
Metadata Date                   : 2018:08:27 14:03:29+08:00
Creator Tool                    : Adobe InDesign CC 13.0 (Windows)
Instance ID                     : uuid:eb8f4918-d0c4-4f3b-b2f9-6283d0d1a74c
Original Document ID            : xmp.did:C1A732EB845EE3119901AE1D2D34838F
Document ID                     : xmp.id:9e9f281c-6e17-ba4b-b15c-1eab69f9347d
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:50fa2baa-8596-2942-8a71-61ab2cbf9810
Derived From Document ID        : xmp.did:C6A732EB845EE3119901AE1D2D34838F
Derived From Original Document ID: xmp.did:C1A732EB845EE3119901AE1D2D34838F
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.0 (Windows)
History Changed                 : /
History When                    : 2018:05:03 15:34:30-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 15
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XVR-CONT8245

Navigation menu