Truly Instrument TET351 Infrared Ear & Forehead Thermometer User Manual

Truly Instrument Ltd. Infrared Ear & Forehead Thermometer Users Manual

Contents

2ABG7-TET351_User manual Rev0

Infrared Ear & Forehead Thermometer  Thank you for purchasing                infrared ear thermometer. Please read through this manual before using the product.● For babies below    12 months: Pull ear    smoothly backward. ● For children above    12 months old and    adults: Pull ear    smoothly upward.  How to pull the ear    Product Description1. Probe2. LCD display3. Power/memory button4. temperature mode button : ear or    forehead5.Measurement button6. Battery coverNormal body temperature range according to World Health Organization(WHO)earOralAxillaryRectal35.8     - 38 oC oC36.6     - 38 oC oC34.7     - 37.3 oC oC35.5     - 37.5 oC oCProduct Application For measurement of body temperature through eardrum and forehead.1.Do not drop or shock the unit.2.Do not immerse the unit into water.3.Keep the unit out of reach by    children.4.If the unit does not function,contact    the dealer.5.Consult doctor if the result of    measurement is out of normal    body temperature range.6.Do not disassemble the unit. Open    the battery cover only when    replacing battery.7.Dispose used battery according to    local recycling regulation.8.The product function maybe reset    when it is subjected to electrostatic    discharge disturbance test. Just    follow the instruction described in    this manual to set the function    again for normal operation. Cautions1.One second measure time.2.LCD display for easy measurement    reading.3.Backlight display.4.Memory for 30 readings.5.Auto power off.Special FeaturesMeasurement Principle Measuring the temperature of the eardrum and forehead with infrared.Cautions                                   2Special Features                  2Measurement Principle              2Product Application                    3Product Description                  3Ear Measurement                  3Connect iOS device via Bluetooth    5Correct Measurement Method   6When the Measurement Result is Abnormal                     6Memory Function                  7Unit (oC/oF) Switch                      7Replacing the Batteries             7Cleaning and Care                  8FCC Statement                          8Product Specifications             10Display Message                10Contents-1-eardrum Ear canaloC36.8Lower measured temperatureeardrumEar canaleardrumEar canal2.For accurate    result, clean the    probe with    cotton bud    before measuring.     1.Ensure the probe is facing eardrum    in straight line. Otherwise, the    measured temperature will be lower    than the actual body temperature. Correct Measurement MethodWhen the Measurement Result is Abnormal1.Possible causes for high    temperature:● After exercise, meal, or crying.● Prolong is staying in high    temperature environment.● Thermometer is taken out from low    temperature environment. Keep    the thermometer in room    temperature for at least 30 minutes     before using.2.Possible causes for low    temperature:● The probe is dirty.● Just exposed in cold temperature    environment before taking    measurement.● Forehead: The probe is not facing    forehead instraight.● The thermometer is pulled out from    the ear before measurement    complete.● The probe is not fitted snugly into    the ear canal.● The probe is not facing the ear    drum or is not placed in a corretive   position in the canal. See “Correct   Measurement Method”.● Excess ear wax build-up.3.Temperatures measured from left    and right ears are different:   There could be slight difference in     temperatures when taking from    both ears. Therefore, always take    the temperature from the same ear.This thermometer is powered by 2 AAA batteries. When the power islow, the low battery signal isdisplayed. To replace batteries:1.Press and push the battery cover to    open it.2.Remove the old batteries and    replace with new ones. Make sure    the batteries are    in right polarity    direction.3.Close the battery    cover.  Note:To protect the environment, dispose of empty batteries at your retail store of at appropriate collection sites according to national or local regulations.  Memory functionThis thermometer stores the last 30  temperature readings.● When power on,  press    power/memory button to recall first    reading.● Repeat pressing power/memory    button to recall the next reading.● Delete memory:   Press both power/memory and    measurement buttons and hold for 3    seconds. The signal “Clr” displayed    and the memory will be deleted.Cleaning and care1.Use a soft, dry cloth to clean the    exterior of the thermometer.2.Keep the thermometer away from    direct sunlight, dust and    contamination environment.3.Store the thermometer in normal    room temperature, or within    10-40oC.      Display message Situation Solution Allow the thermometer remain in room temperature(10-40  C) for 30 minutes. Ambient temperature is out of operating range (10-40       o o C)Sensor error Contact the dealer.Contact the dealer.Temperature measured is higher than normal humantemperature range(above 42.2     ) oC oCCheck the measured object and take a new measure.Temperature measured is lower than normal human temperature range (below 34    )  Check the measured object and take a new measure.Low battery              Replace batteries.Memory error Display MessageMeasurement method  34-42.2 oCAccuracy +/-0.2oCo+/-0.3 C (ambient temp.1 secondLCD displayStores last 30 readings Auto power off 1 minute after not being used 2 x AAA batteries Operating temperature   -20~+55 oCDimensions                     152 x 52 x 36 mm66g (notincluding batteries) Infrared measurementMeasurement rangeMeasuring time             DisplayMemory Batteries oC10-40Storage temperature WeightoC (ambient temp.16-35    )       o   C, 35-40                     o    C)10-16Product SpecificationsReplacing the Batteries-6- -7 -8- -10- -11--9--2- -3- -4-This appliance conforms to the following standards:EN60601-1: Medical electrical                     equipment                      Part 1: General                     requirements for safetyEN12470-5: Clinical thermometers                      Part 5: Performance of                     infrared ear thermometers                     (with maximum device)93/42/EEC : Medical Device DirectiveASTM E 1965-98: Standard                               Specification for                               Infrared                               Thermometers for                              Intermittent                               Determination of                               Patient TemperatureMODEL: TET-351User ManualRev.00   Forehead: While taking the    temperature, the screen indicates    and audible bips sound. As soon    as the probe is placed on the area    of the temple, release the button,    wait for the validation sound beep    before removing the thermometer.4.Interval Between Measurements    If you need to take another    measurement, allow an interval of    8 seconds until the signal “oC (oF)”    flashes. If you press the    Measurement button within 8    seconds, the beep signal will be    sounded.5.Turn off the thermometer   ● Push Power/memory button until       the “OFF” signal is displayed.   ● The thermometer will turn off       automatically without use for 1       minute.2.Infrared: Start measuring Pull ear    smoothly to flatten ear canal and    place the probe facing eardrum in   straight line. Press measurement    button until you hear the beep    signal.note: Press the button           to           select the forehead mode.3.Measurement result   When the measurement is    complete, the temperature will be    displayed with backlight. not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and  (2)This device must accept any interference received, including interference that may cause undesired operation.Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. such modifications could void the user’s authority to operate this equipment.  FCC StatementThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residentialinstallation. This equipmentgenerates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will  -5-Connect iOS device via Bluetooth 1. InstallationPrior to first use, Download and install application to your iOS device. (Bluetooth 4.0 capabilities, e.g. iPhone 4S, iPhone 5, NewiPadand iPadMini).2. Open application, and then press     the Blood Pressure icon on     Measure screen.    3. Press the “Enter” button.  4. Press the “Thermometer” button.  6. This thermometer stores the last      temperature readings:5. When the measurement is     complete, the temperature will     display on Thermometer monitor &     save on iOS application screen.  oCEar Measurement1.Press Power/Memory button Ready    signal beep + All display              + last measurement result              + Ready display        The "     "    symbol is blinking.Unit (oC/oF) SwitchWhen the product is in off state, press and hold "power/memory" button for 10 seconds until the display shows "oC" or "oF" altenately. Release the button when the display is showing your desired unit.123465

Navigation menu