Truly Instrument TET351 Infrared Ear & Forehead Thermometer User Manual

Truly Instrument Ltd. Infrared Ear & Forehead Thermometer Users Manual

Contents

2ABG7-TET351_User manual Rev0

Download: Truly Instrument TET351 Infrared Ear & Forehead Thermometer User Manual
Mirror Download [FCC.gov]Truly Instrument TET351 Infrared Ear & Forehead Thermometer User Manual
Document ID2173076
Application IDselNgBCIA8XUVE2rlmXQhQ==
Document Description2ABG7-TET351_User manual Rev0
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize22.38kB (279708 bits)
Date Submitted2014-01-22 00:00:00
Date Available2014-01-22 00:00:00
Creation Date2014-01-15 08:59:22
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2014-01-15 09:34:03
Document TitleUsers Manual
Document CreatorPScript5.dll Version 5.2
Document Author: 080519001

Contents
Infrared Ear & Forehead Thermometer
Cautions
Special Features
Measurement Principle
Product Application
Product Description
Ear Measurement
Connect iOS device via Bluetooth 5
Correct Measurement Method 6
When the Measurement
Result is Abnormal
Memory Function
Unit ( C/ F) Switch
Replacing the Batteries
Cleaning and Care
FCC Statement
Product Specifications
10
Display Message
10
Thank you for purchasing
infrared ear thermometer. Please
read through this manual before
using the product.
1.Do not drop or shock the unit.
2.Do not immerse the unit into water.
3.Keep the unit out of reach by
children.
4.If the unit does not function,contact
the dealer.
5.Consult doctor if the result of
measurement is out of normal
body temperature range.
6.Do not disassemble the unit. Open
the battery cover only when
replacing battery.
7.Dispose used battery according to
local recycling regulation.
8.The product function maybe reset
when it is subjected to electrostatic
discharge disturbance test. Just
follow the instruction described in
this manual to set the function
again for normal operation.
1.Ensure the probe is facing eardrum
in straight line. Otherwise, the
measured temperature will be lower
than the actual body temperature.
Lower
measured
temperature
36.8 oC
eardrum
eardrum
Ear canal
● The probe is not facing the ear
drum or is not placed in a corretive
position in the canal. See “Correct
Measurement Method”.
● Excess ear wax build-up.
3.Temperatures measured from left
and right ears are different:
There could be slight difference in
temperatures when taking from
both ears. Therefore, always take
the temperature from the same ear.
Ear canal
2.For accurate
result, clean the
probe with
cotton bud
before measuring.
eardrum
Ear canal
When the Measurement Result
is Abnormal
1.Possible causes for high
temperature:
● After exercise, meal, or crying.
● Prolong is staying in high
temperature environment.
● Thermometer is taken out from low
temperature environment. Keep
the thermometer in room
temperature for at least 30 minutes
before using.
2.Possible causes for low
temperature:
● The probe is dirty.
● Just exposed in cold temperature
environment before taking
measurement.
● Forehead: The probe is not facing
forehead instraight.
● The thermometer is pulled out from
the ear before measurement
complete.
● The probe is not fitted snugly into
the ear canal.
-6-
Memory function
This thermometer stores the last 30
temperature readings.
● When power on, press
power/memory button to recall first
reading.
● Repeat pressing power/memory
button to recall the next reading.
● Delete memory:
Press both power/memory and
measurement buttons and hold for 3
seconds. The signal “Clr” displayed
and the memory will be deleted.
Unit (oC/oF) Switch
When the product is in off state,
press and hold "power/memory"
button for 10 seconds until the
display shows " C" or " F" altenately.
Release the button when the display
is showing your desired unit.
Replacing the Batteries
This thermometer is powered by 2
AAA batteries. When the power is
low, the low battery signal is
displayed. To replace batteries:
1.Press and push the battery cover to
open it.
-7
35.8 C - 38 C
34.7 C - 37.3 C
35.5 C - 37.5 C
36.6 C - 38 C
1.One second measure time.
2.LCD display for easy measurement
reading.
3.Backlight display.
4.Memory for 30 readings.
5.Auto power off.
Measurement Principle
-2-
2.Remove the old batteries and
replace with new ones. Make sure
the batteries are
in right polarity
direction.
3.Close the battery
cover.
Note:
To protect the environment, dispose of
empty batteries at your retail store of at
appropriate collection sites according
to national or local regulations.
Cleaning and care
1.Use a soft, dry cloth to clean the
exterior of the thermometer.
2.Keep the thermometer away from
direct sunlight, dust and
contamination environment.
3.Store the thermometer in normal
room temperature, or within
10-40 C.
FCC Statement
This equipment has been tested and
found to comply with the limits for a
Class B digital device, pursuant to
part 15 of FCC Rules. These limits
are designed to provide reasonable
protection against harmful
interference in a residential
installation. This equipment
generates and can radiate radio
frequency energy and, if not
installed and used in accordance
with the instructions, may cause
harmful interference to radio
communications. However, there is
no guarantee that interference will
-8-
note: Press the button
to
select the forehead mode.
2.Infrared: Start measuring Pull ear
smoothly to flatten ear canal and
place the probe facing eardrum in
straight line. Press measurement
button until you hear the beep
signal.
How to pull the ear
● For babies below
12 months: Pull ear
smoothly backward.
Product Application
For measurement of body
temperature through eardrum and
forehead.
Product Description
Special Features
MODEL: TET-351
User Manual
Rev.00
Correct Measurement Method
ear
Axillary
Oral
Rectal
Cautions
Measuring the temperature of
the eardrum and forehead with
infrared.
-1-
Normal body temperature range
according to World Health
Organization(WHO)
1. Probe
2. LCD display
3. Power/memory button
4. temperature mode button : ear or
forehead
5.Measurement button
6. Battery cover
Ear Measurement
1.Press Power/Memory button Ready
signal beep + All display
+ last measurement result
+ Ready display
The " oC "
symbol is blinking.
● For children above
12 months old and
adults: Pull ear
smoothly upward.
Forehead: While taking the
temperature, the screen indicates
and audible bips sound. As soon
as the probe is placed on the area
of the temple, release the button,
wait for the validation sound beep
before removing the thermometer.
3.Measurement result
When the measurement is
complete, the temperature will be
displayed with backlight.
4.Interval Between Measurements
If you need to take another
measurement, allow an interval of
8 seconds until the signal “ C ( F)”
flashes. If you press the
Measurement button within 8
seconds, the beep signal will be
sounded.
5.Turn off the thermometer
● Push Power/memory button until
the “OFF” signal is displayed.
● The thermometer will turn off
automatically without use for 1
minute.
-3-
not occur in a particular installation.
If this equipment does cause
harmful interference to radio or
television reception, which can be
determined by turning the
equipment off and on, the user is
encouraged to try to correct the
interference by one or more of the
following measures:
Reorient or relocate the receiving
antenna.
Increase the separation between the
equipment and receiver.
Connect the equipment into an
outlet on a circuit different from that
to which the receiver is connected.
Consult the dealer or an
experienced radio/TV technician for
help.
This device complies with Part 15 of
FCC Rules. Operation is subject to
the following two conditions: (1)This
device may not cause harmful
interference, and (2)This device
must accept any interference
received, including interference that
may cause undesired operation.
Note: The manufacturer is not
responsible for any radio or TV
interference caused by unauthorized
modifications to this equipment.
such modifications could void the
user’s authority to operate this
equipment.
-9-
Connect iOS device via Bluetooth
1. Installation
Prior to first use, Download and install
application to your iOS device.
(Bluetooth 4.0 capabilities,
e.g. iPhone 4S, iPhone 5, NewiPad
and iPadMini).
2. Open application, and then press
the Blood Pressure icon on
Measure screen.
3. Press the “Enter” button.
5. When the measurement is
complete, the temperature will
display on Thermometer monitor &
save on iOS application screen.
6. This thermometer stores the last
temperature readings:
-5-
-4-
Product Specifications
Infrared measurement
Measurement method
4. Press the “Thermometer” button.
Measurement range
34-42.2 oC
Accuracy
+/-0.2 oC
(ambient temp.16-35 oC)
+/-0.3 oC (ambient temp.
10-16 o C, 35-40oC)
Measuring time
1 second
Display
LCD display
Memory
Stores last 30 readings
Auto power off
1 minute after not being
used
Batteries
2 x AAA batteries
Operating temperature
10-40 C
Storage temperature
-20~+55 C
Dimensions
152 x 52 x 36 mm
Weight
66g
(notincluding batteries)
This appliance conforms to the
following standards:
EN60601-1: Medical electrical
equipment
Part 1: General
requirements for safety
EN12470-5: Clinical thermometers
Part 5: Performance of
infrared ear thermometers
(with maximum device)
93/42/EEC : Medical Device Directive
ASTM E 1965-98: Standard
Specification for
Infrared
Thermometers for
Intermittent
Determination of
Patient Temperature
Display Message
Display
message Situation
Solution
Ambient temperature Allow the
is out of operating
thermometer remain
range (10-40 oC)
in room temperature
(10-40 oC) for 30
minutes.
Sensor error
Contact the dealer.
Memory error
Contact the dealer.
Check the measured
Temperature
measured is higher object and take a
than normal human new measure.
temperature range
(above 42.2 C )
Temperature
measured is lower
than normal human
temperature range
(below 34oC )
Check the measured
object and take a
new measure.
Low battery
Replace batteries.
-10-
-11-

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2014:01:15 09:34:03+08:00
Create Date                     : 2014:01:15 08:59:22+08:00
Metadata Date                   : 2014:01:15 09:34:03+08:00
Format                          : application/pdf
Title                           : <5445542D3335315452554C59C0B6D1C0D3A2CEC4CBB5C3F7CAE92E706466>
Creator                         : 080519001
Document ID                     : uuid:7de34d4c-7cb7-4d8f-914b-93db08dd7fc1
Instance ID                     : uuid:3da0b21e-29f9-4723-802d-ecd08ceeced9
Page Count                      : 1
Author                          : 080519001
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ABG7-TET351

Navigation menu