White Rodgers 16E09 101 Electronic Temperature Control Specification Sheet 130516_16E09_101_ETempCntrl_SS
2015-03-28
: White-Rodgers White-Rodgers-16E09-101-Electronic-Temperature-Control-Specification-Sheet-676458 white-rodgers-16e09-101-electronic-temperature-control-specification-sheet-676458 white-rodgers pdf
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
Electronic Temperature Control Universal Save tes Minu 6 30 0 llation a t s In Time 16E09-101 • Refrigeration or Heating Applications • Alarm Output with Selectable Delay Prevents false alarms • No Common Wire Required* Saves 30-60 minutes installation time when upgrading a mechanical control Multiple Input Voltage (24/120/208/240 Volts AC) *Electrical load must be greater than 2.5 amps and uninterrupted Superior Temperature Control and Accuracy for Both Refrigeration and Heating Applications...and It’s Universal, Too! • 16E09-101 replaces most mechanical and electronic single stage controls using an SPDT output relay • Offers the widest multiple voltage operating range: 24/120/208/240 VAC for truly universal replacement • Does not require a common wire when electrical load is greater than 2.5 amps — saving 30 to 60 minutes installation time when upgrading a mechanical control • Offers a wider than industry standard setpoint temperature range (-40°F to 220°F) and adjustable differential settings • Reduces inventory — 16E09-101 replaces most competitive mechanical and electronic refrigeration controls Features Applications Includes Multiple Input Voltages (24/120/208/240 Volts) Convenience Store Freezer Control NTC Sensor with 7.5-Ft. Leads Reach-In Coolers Cross-Reference Replacement Guide No Common Wire Required (Electrical load must be greater than 2.5 amps and uninterrupted) Supermarket Display Cases (meat/produce) Boiler Control Optional Multiple Sensor (4) Averaging Restaurant/Convenience Store Walk-In Coolers Electronic Temperature Accuracy Condenser Fan Cycling Alarm Output (with selectable delay – up to 99 minutes) Pump Control Adjustable Anti-Short Cycle Delay Space and Return-Air Temperature Setpoint Locking Function Job #: WRDG_130516 File Name: 130516_16E09_101_ETempCntrl_SS.ai Printing & Finishing: 4/C Offset Colors: CMYK DIE Revision: 04 Time: 10a Size: 8.5" x 11" Updates: jd07.15.10, jd07.19.10, jd07.28.10, BBpff8.13.10 Printout Size 100% This printout is for indicating color breaks only. Do not use for color matching. Do not measure for accuracy. 16E09-101 Universal 24/120/208/240 Volts 16E09-101 Universal Replacement • Alarm Output with Selectable Delay Prevents false alarms • No Common Wire Required (Electrical load must be greater than 2.5 amps and uninterrupted) Saves 30-60 minutes installation time when upgrading a mechanical control Electronic Refrigeration or Heating Control Control Material Cover and Case: NEMA 1 high-impact plastic Thermoplastic: Non-flammable UL94V0 Specifications Setpoint Range: -40° to 220°F (-40° to 104°C) For Additional Information Visit www.white-rodgers.com Load Relay Electrical Ratings N.C. and Load Contacts (Maximum Load Current) Switch Action: SPDT Differential Range: 1° to 30°F (1° to 30°C) Ambient Humidity: 0 to 95% RH, non-condensing Supply Voltage: 24/120/208/240 VAC, 60Hz Dimensions Sensor: Negative Temperature Coefficient with 7.5-Ft. Leads (Maximum length for remote temperature sensing – 400 feet) 6 3/4" L x 3" W x 2 9/16" D Control Enclosure Ambient Temperatures Operating: -29° to 140°F (-34° to 60°C) Storage: -40° to 185°F (-40° to 85°C) Immersion Well: F89-0286 Replacement 7.5-Ft. NTC Remote Sensor: F136-0114 Well Heat Transfer Compound: F145-0650 16E09-101 Optional Accessories/Service Items Applied voltage: 120 VAC Full load amps: Locked rotor amps: Non-inductive amps: Horsepower: 24 VAC: Pilot duty: Minimum load: 16 Amps 9.2 Amps 8 Amps 96 Amps 55.2 Amps 48 Amps 16 Amps 16 Amps 16 Amps 1 hp 1 hp 1 hp 100 VA, 30 VAC Max. (Class 2) 125 VA, 24 to 240 VAC 1 Amp @ 24 VAC 208 VAC 240 VAC Alarm Relay Electrical Ratings N.O. contacts: 1 Amp (5 to 24 volts AC or DC) Typical Wiring Line Voltage Application (Non-Power Stealing) Line Voltage Application (Power Stealing) Alarm Output For optional connection to customer alarm equipment PTC NTC Binary Input (Gold-Plated Contacts) NTC* Temperature Sensor PS SW2 NON PS Alarm Output For optional connection to customer alarm equipment PTC* Temperature Sensor GND BIN NTC Binary Input (Gold-Plated Contacts) PS SW2 NTC* Temperature Sensor LOAD LINE NEUT NC Load Note: Do not use Output Relay to control Line Voltage when using 24 VAC Power SW2 24 VAC TH TR Voltage Input 120 VAC 208/240 VAC Hot L1 Neutral L2 24 VAC TH - Thermostat Hot TR - Thermostat Return PS NON PS LOAD LINE NEUT NC LOAD LINE NEUT NC Voltage Input 120 VAC 208/240 VAC Hot L1 Neutral L2 GND BIN Binary Input (Gold-Plated Contacts) NON PS 24 VAC TH TR PTC ALARM PTC* Temperature Sensor GND BIN ALARM PTC NTC NTC* Temperature Sensor Alarm Output For optional connection to customer alarm equipment ALARM PTC* Temperature Sensor VAC Applications (Non-Power Stealing) 24 VAC TH TR 24 VAC TH - Thermostat Hot TR - Thermostat Return 24 VAC Class 2 Transformer 24 VAC TH - Thermostat Hot TR - Thermostat Return Load Load *Note: Alarm connection contacts close when sensor fails or temperature range is exceeded. NTC - Negative Temperature Coefficient PTC - Positive Temperature Coefficient Note: Sensor type (PTC or NTC) must meet temperature specifications. If averaging, 4 sensors of the same type must be used. 16E09-101* Replaces the Following Models Danfoss UT72 Honeywell T4031A1073 T4031C1004 T4031C1012 T6031A1029 T6054A1005 T6054A1054 T675A1045 T675A1136 T675A1425 T675A1441 T675A1458 T675A1508 T675A1516 T675A1524 T675A1540 T675A1565 T675A1706 T675A1722 T675A1771 T675A1854 T675F1032 *16E09-101 is not rated as a limit control T678C1005 T7079A1004 T7079A1012 T7079A1046 T7079A1053 †16E09-101 Ranco ETC Commercial Temperature Controls 060-100† 060-101† 060-109† 060-200† ETC-111000 ETC-112000 Job #: WRDG_130516 Printing & Finishing: 4/C Offset Colors: CMYK DIE A319ABC-24-01 A320ABC-1C A419ABC-1C White-Rodgers 1609-33† 1609-100† 1609-101† 1609-102† 1609-103† 1609-104† 1609-105† 1687-9† 201-8† 201-20† 230-22† 241-2† 2A37-1† is a replacement on non-inductive applications up to 16 amps St. Louis, Missouri 314-553-3600 www.white-rodgers.com www.emerson.com File Name: 130516_16E09_101_ETempCntrl_SS.ai Johnson Controls A19ABA-40C† A19ABC-24C† A19BAB-3C† A19BAC-1C† A19BAF-1C A19BBC-2C† A319ABC-12-01 Revision: 04 Time: 10a Size: 8.5" x 11" The Emerson logo is a trademark and a service mark of Emerson Electric Co. Updates: jd07.15.10, jd07.19.10, jd07.28.10, BBpff8.13.10 WR-4975-2 Printout Size 100% This printout is for indicating color breaks only. Do not use for color matching. Do not measure for accuracy.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:30 Create Date : 2010:08:13 10:00:29-05:00 Modify Date : 2010:08:13 10:09:19-05:00 Creator Tool : Adobe Illustrator(R) 13.0 Metadata Date : 2010:08:13 10:09:19-05:00 Producer : Acrobat Distiller 8.2.0 (Macintosh) Format : application/pdf Creator : BillBarta Title : 130516_16E09_101_ETempCntrl_SS.ai Document ID : uuid:8b74461d-c13c-9e44-ba19-af4b5310f548 Instance ID : uuid:05662a88-8db4-1b49-bf2d-01bbc4ed6793 Page Count : 2 Author : BillBartaEXIF Metadata provided by EXIF.tools