Zebex Z-217XP Handheld Terminal (WIFI & BT) User Manual
Zebex Industries Inc Handheld Terminal (WIFI & BT) Users Manual
Zebex >
User Manual
Handheld Computer Z-2170 User’s Manual ( Version 1.02) ZEBEX INDUSTRIES INC. Editorial Record Version Date of edited Ver1.00 2014/05/14 Subject Z-2170 Plus User’s Manual Page Content Initial release Version 1.00 Date 2014/05/14 Page 2 / 44 ZEBEX INDUSTRIES INC. Table of Contents Preface ......................................................................................................... 4 About This Manual.............................................................................................................. 4 Copyright............................................................................................................................. 5 Safety Information............................................................................................................... 5 Unpacking .................................................................................................... 7 Package Contents ................................................................................................................ 7 Optional Parts...................................................................................................................... 8 General Guide ........................................................................................... 11 Getting Started .......................................................................................... 13 Inserting the Battery .......................................................................................................... 13 Remove the Battery........................................................................................................... 13 Charging the Battery ......................................................................................................... 14 System Reset ..................................................................................................................... 17 PC System Requirements .................................................................................................. 18 Connecting To PC ............................................................................................................. 18 Specifications .................................................................................................................... 20 Using Barcode Scanner ........................................................................... 21 Scanning Barcodes ............................................................................................................ 21 Volume Control ................................................................................................................. 22 Using the Zebex PowerPack ................................................................... 23 Backlight ........................................................................................................................... 23 Calculator .......................................................................................................................... 25 File Transfer....................................................................................................................... 26 Function Key Manager...................................................................................................... 29 Preload Manager................................................................................................................ 34 Preload Operation.............................................................................................................. 35 Switch................................................................................................................................ 38 Scan Manager .................................................................................................................... 40 Backup/Restore.................................................................................................................. 43 Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 3 / 44 ZEBEX INDUSTRIES INC. Preface About This Manual Thank you for your purchase of the ZEBEX Z-2170 Plus Handheld Terminal. ZEBEX Z-2170 Plus is at the forefront of handheld terminal technology, and this manual will provide the necessary information on the many and varied options available to you. The Z-2170 Plus is a compact, ergonomic, modular and durable handheld terminal. It is designed for easy upgrade with an integrated WiFi wireless communication, 1D barcode scanner and 2D Imager, solution. The design is complies with IP54 regulations and ideal for the mobile worker as it simple and easy to use anywhere along a supply chain. Symbols used in this manual A triangular shape indicates you should exercise caution. A circle shape indicates something you should not to do. A black circle indicates something you must to do. A note symbol indicates the information is important and you should observe. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 4 / 44 ZEBEX INDUSTRIES INC. Copyright ZEBEX Industries Inc. makes no warranty of any kind with regard to this material. Including but not limited to the imply warranties of merchantability and fitness for a particular purpose. ZEBEX Industries Inc. shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance or use of this product. ZEBEX Industries Inc. will be under no liability in respect of any defect arising from fair wear and tear, willful damage, negligence, abnormal working conditions, failure to follow the instructions and warnings, or misuse or alteration or repair of the products without written approval. No part of this document may be reproduced, transmitted, stored in a retrieval system, transcribed or translated into any language or computer language in any form or by any means electronic, mechanical, magnetic, optical, chemical, manual or otherwise, with express writ- ten consent and authorization. We reserve the right to make changes in product design without reservation and without notification. The material in this guide is for information only and is subject to change without notice. ZEBEX is a registered trademark of ZEBEX INDUSTRIES INC. © Copyright 2014 ZEBEX. Safety Information Your safety is of the utmost importance so please observe and follow the following guidelines that allow you to use the scanner in a safe and responsible way. Laser Safety The Z-2170 Plus handheld terminal complies with safety standard IEC825-1(1993) for a Class 2 laser product. It also complies with U.S.21CFR1040 as applicable to a Class II laser product. Avoid staring at direct laser light as the laser beam may hurt your eyes. LASER BEAM Never look directly into the laser beam. Doing so can cause eye damage. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 5 / 44 ZEBEX INDUSTRIES INC. Safety Operation WARNING Disassembly and Modification Never try to disassemble or modify the device in any way. All servicing should be carried out be qualified Zebex personnel or Zebex- approved engineers. Interior Parts and Components Never touch interior high voltage parts or components. Doing so creates the danger of electrical shock. Drop and Knock the Device Be careful when using the device; do not drop or knock the device as irreversible damage to the unit may occur. Extreme temperature Do not operate the device under extreme temperature. Battery and Charger The use of third-party battery or charger may either damage the device or shorten the life of the device. CAUTION Dropping and Damage Should the drop the device and damage it, immediately turn off the power and contact your original dealer or an authorized ZEBEX service provider. Continued use creates the danger of fire and electrical shock. Abnormal Conditions Should the device become hot or start to emit smoke or an original dealer or an authorized ZEBEX service provider. Continued use creates the danger of fire and electrical shock. Foreign Objects Should any foreign matter ever get into the device, immediately turn off the power and contact your original dealer or an authorized ZEBEX service provider. Continued use creates the danger of fire and electrical shock. Moisture Keep the device away from vases, planters, cups, glasses and other containers of liquid. Also keep it away from metal. Water and metal getting into the device creates the danger of fire and electrical shock. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 6 / 44 ZEBEX INDUSTRIES INC. Unpacking Package Contents Power Adapter Z-2170 Plus selection Type: North America/Japan/ Taiwan/Europe Handheld Terminal Battery Pack Stylus Pen Sling (for stylus Pen) Hand strip Holder Hand Strip Hand Strip Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 7 / 44 ZEBEX INDUSTRIES INC. Optional Parts Cradle package Docking Cradle RS232 Cable (Connect from cradle tp PC) Power Adapter USB cable (From Cradle to PC USB port) Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 8 / 44 ZEBEX INDUSTRIES INC. Purchaseable accessories Power Adapter Britain Plug head RS232 Cable U.S. Plug head USB cable (From Cradle to PC USB port) Australia Plug head Main Battery Stylus Pen Subject Z-2170 Plus User’s Manual Europe Plug head Version 1.00 Date 2014/05/14 Page 9 / 44 ZEBEX INDUSTRIES INC. Sling (for stylus Pen) Hand strip Holder Hand Strip Britain Adapter Head Australia Adapter Head Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 10 / 44 ZEBEX INDUSTRIES INC. General Guide LED indicator (Left) Indicates the status of read barcode : Green for successful read. LED indicator (Right) Indicates the status of battery charge : Red for battery charging and Green for full. LCD screen Display various data when a program is being run. Scan button The trigger of barcode reading. Keypad Reset switch (inside the hole) Scan windows Emits a laser for barcode reading. Buzzer Outputs operation confirmation tones. Stylus pen For touch screen operation and needle for press RESET switch. 10 Hand strip Protects the Handheld Terminal from dropping. 11 Battery Main battery 12 Communication port Connect to cradle for communication or charging 13 Memory Expansion Slot MicroSD expansion slot Subject Z-2170 Plus User’s Manual A total of 29 keys are provided to the power and other function keys. Use reset needle (take off the other side of stylus pen cover) to press the RESET switch located inside the Version 1.00 Date 2014/05/14 Page 11 / 44 ZEBEX INDUSTRIES INC. ENT Escape Key SCAN ENT Backspace Key Arrow Key abc 2 def 3 ghi jkl 6 pqr stu 8 vwx mno Enter Key 9 yz Alphanumeric Key 0@ F1 F2 F3 F4 Power Key Function Key Space Key Tab Key Shift Key Using the Keypad ENT Enter key Press to confirm entries or commands. BS Backspace key Press to move cursor and deletes the previous character each time. Arrow Arrow keys Press these to move around the screen. 0-9 Alphanumeric keypad Press to enter numerical or alphabetical data. F1-F4 Function keys Press to access function keys 1-4. SP Space key SF/Fn Shift key TAB Tab key Press to add a space character. The key is used in combination with other keys to type special characters or perform other function keys. 1. Press after SF/Fn key and press Up key to turn the input method into upper alphabetical. 2. Press after SF/Fn key and press Down key to turn the input method into lower alphabetical. 3. Press after SF/Fn key and press Left or Right key to turn the input method into numerical. 4. Press after SF/Fn key and press F1-F4 key to F a tab F8 kindention. Press fto add ESC Power 1. Press to turn the power on 2. Press to turn the power off and go into the suspend mode. Escape key Press to perform a cancel action. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 12 / 44 ZEBEX INDUSTRIES INC. Getting Started Inserting the Battery Insert the battery pack as shown and make sure it is aligned correctly. Remove the Battery Push the side lock to unlock the lid and remove the battery pack. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 13 / 44 ZEBEX INDUSTRIES INC. Charging the Battery The Li-ion rechargeable battery can be charged while inserted in the recharging slot of the cradle. Charging by cradle USB Interface AC Power Adapter Jack In RS232/COM port Interface Cradle - rear view Left LED Right LED Cradle-front view Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 14 / 44 ZEBEX INDUSTRIES INC. Cradle LEDs Left LED - The LED lit when a battery is inserted into the rear battery slot of the cradle for recharge. It remains lit until the charge is complete. Right LED - The LED lit when the cradle is connected to AC power. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 15 / 44 ZEBEX INDUSTRIES INC. Charging the battery in the cradle Insert the battery into the compartment at the rear of the cradle. Connect the power jack to the cradle and plug AC adapter into the socket. NOTES When charging the battery for the first time, charge for at least 12 hours prior to use. When charging the battery for the first time, be sure to turn the switch to the ON position as illustrated below to turn on the backup battery and avoid the low battery message on the screen. Off ON Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 16 / 44 ZEBEX INDUSTRIES INC. System Reset Using the Warm reset function Warm reset function allows you to return the device to the default settings, wile not wiping all data from the memory. Insert the needle into the reset hole as shown and press down gently, to reset the device. ENT SCAN ENT abc def 3 ghi jkl mno 6 pqr stu 8 vwx 9 yz 0@ F1 F2 F3 F4 Reset Using the Cold reset function Cool reset function allows you to return the device to the factory settings, wile wiping all data from the memory. Press down and hold the power key for 8 seconds to cold reset the device. WARNING Cold reset will erase ALL pre-configured data on the scanner. Check carefully to make sure you have uploaded all important files to your PC before proceeding with the reset. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 17 / 44 ZEBEX INDUSTRIES INC. PC System Requirements Windows XP Operating System 256 MB RAM 2 GB free HDD space USB ports communication Interface WLAN transmitter (optional) Bluetooth transmitter/receiver (optional) Connecting To PC In order to use the software supplied with the Terminal, the mobile data terminal must be connected to a PC. Connecting via USB Cradle The cradle must also be connected via one of your PC’s USB ports. Attach one end of the cable to the USB interface on the cradle and the other to your PC. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 18 / 44 ZEBEX INDUSTRIES INC. About The Product The Z-2170 Plus is a compact, ergonomic and durable portable data terminal. It is designed with an integrated wireless communication and 1D laser barcode scanner, touch screen and 29-keys keypad. The design is ideal for the mobile worker as it simple and easy to use anywhere along a supply chain. It complies with IP54 regulations. The Z-2170 Plus features a Ti AM3715 ARM Cortex-A8 (1GHz) with Windows CE.NET version 6.0 operation system. This combination delivers high performance, low power consumption and the diversity of a wireless networking platform. Compared with other systems currently available on the market, Z-2170 Plus is the most cost-effective to offering optimum performance. Features Pocket size design Microsoft Windows CE.NET 6.0 operating system 2.4” TFT color display with touch pane Micro SD I/O Slot for extra storage or Wireless solution with IEEE802.11b/g Easy system control tools – PowerPack, saving time and cost for software development Prerequisites Skills Required The following skills are required by developers aiming to develop application software for the ZEBEX Z-2170 Plus. ● Windows programming ● Good knowledge of one or more of the following: * Visual C++ * Visual Basic .NET * Visual studio .NET * Visual C# * Active Server Pages and web programming The following skills or experiences are also desirable. ● Windows CE devices ● IE 6.0 ActiveSync ● Some networking experience Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 19 / 44 ZEBEX INDUSTRIES INC. Specifications Model System CPU Memory LCD Display Audio Z-2170 Plus Windows CE 6.0 Ti AM3715 ARM Cortex-A8 1GHz 512 MB flash ROM/512 MB flash RAM 2.4" QVGA, TFT (240 x 320) One speaker output, AC97 Codec with speaker output and touch panel control Internal Microphone input Operating System Main Battery Backup Battery Vibrator Scan Engine Light Source Scan Rate Print Contrast Decoding Capability Barcode Symbologies 3.7V 2,200mAH Li-ion rechargeable battery One rechargeable Li-ion backup battery Only Barcode Scan OK 1D engine or 2D Imager 650 nm visible Laser Diode 100 scans per second 30% @ UPC/EAN 100% UPC/ EAN/ JAN, Code 128/EAN 128, Code 39, Code 93, Interleaved 2 of 5, Discrete 2 of 5, Codabar, MSI/Plessey 1 x Micro SD I/O card RS-232, USB 2.0 802.11 b/g/n BT 2.1+EDR (L) 162 mm x (W) 60.0 mmx (H) 37.3 mm Approx. 280 g (battery included) Card Slots Communications / Interfaces WLAN Bluetooth Dimensions Weight Environmental Operating Temp. Storage Temp Operating Humidity Drop Durability Environmental Sealing Regulatory Approvals Cradle 0°C ~ 50°C -20°C ~ 60°C 5% ~ 95% (non-condensing) Withstand 1.5M drop to concrete IP54 rated sealing CE & FCC Part 15B Single slot USB / RS-232 charging cradle with spare battery slot IE6.0 / Active sync / Update from Micro-SD card / PowerPack Utility / Support Software SDK Software &Development Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 20 / 44 ZEBEX INDUSTRIES INC. Using Barcode Scanner Scanning Barcodes The Z-2170 Plus is a highly versatile tool that can scan a wide range of barcodes but it is imperative that it is used in the correct manner. To scan a barcode: 1. Hold the Z-2170 Plus horizontally and point it directly at the barcode you wish to scan. 2. Once in the correct position, press the SCAN button. An audible alarm is heard and the barcode digits will appear on the LCD screen if the scan is successful. Barcode Scanning Position This device can read from 30 to 180mm distance. 1. Position the laser scanner close to the barcode when scanning small barcodes. And position it is a distance from the barcode when scanning large barcodes 2. The reader can be detected by a red beam. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 21 / 44 ZEBEX INDUSTRIES INC. Band Scanning Position Make sure that the bars enter the laser beam when scanning large barcodes. Scanning operations may fail if the laser beam are positioned incorrectly as below. Caution: Never look directly into the laser or shine the laser into the eyes. Volume Control To set the volume, go to Control Panel and click on Volume and Sound. Or press [SF/Fn] on the keypad; press F1 for volume up or F2 for volume down. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 22 / 44 ZEBEX INDUSTRIES INC. Using the Zebex PowerPack “PowerPack” designed by Zebex provides an easy to use system management tool. It saves users time and effort in developing applications. The PowerPack management tool is included in each of our WinCE product. It is free of charge and offers useful functions without any programming skills from the users. To access PowerPack, follow below path from the home screen: Start >> Programs and choose “PowerPack” Backlight This application is for setting the LCD panel and key pad bakclight. It allows operators to set the duration or to turn it on or off. The Backlight settings screen include 2 parts: LCD Panel Keypad Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 23 / 44 ZEBEX INDUSTRIES INC. The LCD Panel setting: Auto Timeout: This function is used to turn off the LCD backlight automaticually after certain period of inactivity. You can set the Auto off time from 15 sec to 15 min using the Timer setup as illustrated below. Always ON: This function is used to set the backlight to always on until the system goes into suspend mode. Always OFF: This function is used to set the backlight to always off. The Keypad Backlight setting: Auto Mode: This function is used to set the keypad backlight to auto off after certain period of inactivity. The interval of the time for auto off is fixed on 5 seconds. Always ON: This function is used to set the keypad backlight to always on until the system into suspend mode. Always OFF: This function is used to set the backlight to always off. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 24 / 44 ZEBEX INDUSTRIES INC. Calculator This calculator function allows operators to add, subtract, multiply, and divide that simply provide basic logistic function in our daily basis. The upper zone of the display area displays the memory content, and the lower zone is key pad. Button description: MC MR MS M+ CE +/0~9 * : Clear buffer of memory. : Got the value of buffer. : Storage the value to buffer. : Append the value to the buffer. : Clear the display area to “0”, but keep the value in buffer. : Clear the display and the buffer of memory. : Change the value sign form Plus to Minus or Minus to Plus. : Numeric key. : Division function. : Multiplication function. - : Subtraction function. + : Addition function. ﹒ : A decimal point of dot. = :To be equal to, The amount. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 25 / 44 ZEBEX INDUSTRIES INC. File Transfer File Transfer is a simple file transferring tool. It lets users transfer files to another device via Bluetooth. OBEX agreement which is used by cell phone and Notebook PC is also used here so you can transfer files to cell phone or Notebook PC, or perform file transfer between two terminals using this application. File Transfer is capable to auto-search devices with Bluetooth communication, so all devices within valid range will be listed in window of “1. Select Remote Device”. Function Instructions: Select Remote Device All devices with Bluetooth Communication functions are listed on the display. Query: For searching usable devices. Stop: Stop searching. Connect: For connecting with one device. Disconnect: For disconnecting with current devices. Select Transfer File Select file need to be transferred, press button for selecting file. Start Transfer: Start transferring file to targeted devices. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 26 / 44 ZEBEX INDUSTRIES INC. Ex. File Transfer By Using Bluetooth File Transfer by Bluetooth: Make sure Bluetooth devices are activated, Bluetooth Communication Devices can be activated under Switch Function within PowerPack software utilities. Select “Query“ for searching Bluetooth devices, below window will pop up on display. 1. Select Bluetooth devices for receiving file, select “Connect” for connecting with devices, or select “Disconnect” to disconnect with current devices. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 27 / 44 ZEBEX INDUSTRIES INC. 2. Click ” … ” button to select the file need to be transferred, then click ”OK ” button to confirm. 3. Select “Start Transfer” button to start file transferring. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 28 / 44 ZEBEX INDUSTRIES INC. Function Key Manager This application utility provides an easier way to configure the function keys for your device. Through this application you can set the keys to instantly start programs like Window Media Player, Calculator, or any application program you wish including windows system function such as increasing or decreasing the volume or adjusting the brightness of your LCD panel. You can find this application from “\settings\control Panel\”. Program provides eight different function keys (F1~F8) for the setting. Default settings are shown as below: F1: SIP ON/OFF F2: Backlight Manager F3: Power Switch F4: Backup/Restore F5: Volume + F6: Volume F7: Backlight + F8: Backlight - Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 29 / 44 ZEBEX INDUSTRIES INC. Function Key Manager Set Up Instruction Enable/ Disable : Enable or Disable Function Key. Internal Function : SIP ON/OFF Backlight Manager Power Switch Stylus Calibration Wi-Fi ON/OFF Bluetooth ON/OFF Backup/Restore Volume + Volume – Backlight + Backlight – Cut Copy Paste Program File : Install application program according to demand, this function can be used for setting up auto-execution. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 30 / 44 ZEBEX INDUSTRIES INC. Edit Internal Function items: 1. Select the item to be modified by clicking the ”Edit” button to enter the configuration window as below: 2. Select a new functional item and select “OK” to complete setting. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 31 / 44 ZEBEX INDUSTRIES INC. Edit application software for auto-execution: 1. Select Program File checkbox and click “Browse” to browse files. 2. Select the software required for auto-execution, then select “OK” to complete the selecting process. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 32 / 44 ZEBEX INDUSTRIES INC. 3. The selected program will appear in the column. Select ”OK“ to complete the editing process. When Function Key Manager reappears on the display, the function key is updated with the new program. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 33 / 44 ZEBEX INDUSTRIES INC. Preload Manager The Preload Manager is an auto execution program for starting programs at system boot. Preload Manager has 2 main functions: Priority and Edit. Priority: Providing “UP”and “DOWN” two selections for adjusting priority on the lists. Edit: Providing ”Remove“ and “Browse..” two functionalities, below are instructions: Remove: Deleting selected functionalities. Browse: Selecting program for preloading, files can be selected from window by clicking Browse buttons. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 34 / 44 ZEBEX INDUSTRIES INC. Preload Operation Selected Program: 1. By clicking ”Browse..”, below menu will appear, select preload program by using folder. Programs can be selected more than once. 2. Confirming file by clicking “OK” will get back to Preload Manager main page. Then complete its process. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 35 / 44 ZEBEX INDUSTRIES INC. Reset preload priority: If the preload priority need to be set up to (1)play music -> (2)open explorer -> (3)check everything, please follow steps listed below: 1. Select by clicking play music.exe program and click ”Up” button to move up the music.exe. 2. Then select by clicking check everything program and click “Down” button to move down check everything program. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 36 / 44 ZEBEX INDUSTRIES INC. Remove a program: In order to remove “open explorer” program, select by clicking program, then select “Remove” by clicking on button to finish command. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 37 / 44 ZEBEX INDUSTRIES INC. Switch The WiFi and Bluetooth switch utility. To turn these functions on or off, simply tick the check box of the functions. Wireless configuration window appears when the WiFi selection is ticked. A list of SSID will appear automatically after scanning. Select a SSID from the list and hit “Connect” to enter the Wireless Properties screen. Select the network type and enter the passkey then select “OK” to connect to the network. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 38 / 44 ZEBEX INDUSTRIES INC. You may also select “Advanced” tab to setup your preferred networks. To manage your preferred networks, select Up or Down to change their priorities or select delete to delete the network. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 39 / 44 ZEBEX INDUSTRIES INC. Scan Manager The Scan Manager program is a barcode reader set up program, it offers you an easy way to enable or disable the barcode scanner, and also offer you to set up each barcode symbolic properties. Below are instructions of functions on main page: Output Mode: provides three output methods such as Copy & Paste / Key Emulation / None (Copy to Clipboard). Copy & Paste: Copy and paste the barcode information into application that need to execute data as input. (ex. WordPad) Key Emulation: Transfer barcode information via Key Emulation to executed software’s edit window. Key Emulation function can also be used for barcode scanning under conditions of Terminal Emulation, Command Prompt and some other program without touch panel. Read data will be transferred to application program. None (copy to clipboard): Function provide required barcode information to application program, after this function was activated, scanner will read barcode information and save data into clipboard. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 40 / 44 ZEBEX INDUSTRIES INC. Terminal Character: Set the terminator control code with barcode data. It offers “Enter”, “Space”, “Tab”, and “None” for selections. Terminator control code will be sent every time when barcode was read. Suffix: Set the suffix character with barcode data. Prefix: Set the preamble character with barcode data. Vibrator: Select to switch to the vibrator mode. Settings: To set the barcode parameter value of each kind of barcode for barcode scanner. Press the "Setting" button in the application to start the barcode setting. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 41 / 44 ZEBEX INDUSTRIES INC. To check the barcode type selection for enable the type of barcode for read, press the "Properties" tab on top to see the barcode parameter value of each kind of barcode. The default values of EAN/UPC code and Code39: Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 42 / 44 ZEBEX INDUSTRIES INC. Backup/Restore You can find this application at the desktop or from Control Panel, Backup/Restore. This application provides you an easy way to backup or restore the device setting using Flash Disk and storage card. Flash Disk can be used when there is no storage card. When a SD Card is installed into the device, the program will detect it automatically and make the SD Card selection available. Subject Z-2170 Plus User’s Manual Version 1.00 Date 2014/05/14 Page 43 / 44 ZEBEX INDUSTRIES INC. Backup: Select the storage for saving the data then select ”Backup” to proceed with the backup. Display will restore when backup is finished. Restore: To restore your settings, press the “Restore” button. NOTES Subject Z-2170 Plus User’s Manual Barcode settings are not backed up by this function. To back up your barcode settings please use barcode setting->Export/Import Setting. Backup time may vary depending on the size of data you have on the device. When restoring system, you must select “Yes” to warm boot the device to complete the process. Version 1.00 Date 2014/05/14 Page 44 / 44 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. 15.21 FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. 15.19 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC RF Radiation Exposure Statement: 1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter RF exposure procedures. 2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. Europe - EU Declaration of Conformity This device complies with the essential requirements of the R&TTE Directive 1999/5/ EC with essential test suites as per standards: EN 300 328: Electromagnetic compatibility and Radio Spectrum Matters (ERM); Wideband transmission systems; Data transmission equipment operating in the 2.4 GHz ISM band and using spread spectrum modulation techniques EN 301 489-17: Electromagnetic compatibility and Radio Spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for 2.4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment EN 60950-1: Safety of information technology equipment, including electrical business equipment EN 62311: Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz) Translated Statements of Compliance Hereby, declares that this product is in compliance with the essential require-ments and other relevant provisions of Directive 1999/5/EC.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 47 Page Layout : OneColumn XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:03d59da7-51fe-47fe-90bc-36978421a7c3 Producer : Acrobat Distiller 9.3.3 (Windows) Keywords : Company : ZBT Comments : Source Modified : D:20140604085104 Create Date : 2014:06:04 16:52:34+08:00 Creator Tool : Acrobat PDFMaker 9.1 for Word Modify Date : 2014:10:02 17:40:16+08:00 Metadata Date : 2014:10:02 17:40:16+08:00 Document ID : uuid:4b1c5bf6-007f-437f-a52c-c7785d356d96 Instance ID : uuid:2027775e-baaf-461b-a315-03a5c46b259f Subject : 91 Format : application/pdf Creator : GLLS Title : 簡易使用說明 Description : Tagged PDF : No Author : GLLSEXIF Metadata provided by EXIF.tools