for these products or systems, the user, through his own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance and safety requirements of the application are met. The products are subject to change by Parker Hannifin GmbH at any time without notice.
Europe, Middle East, Africa. AE – United Arab Emirates,. Dubai. Tel: 971 4 8127100 parker.me@parker.com. AT – Austria, St. Florian. Tel: 43 (0)7224 66201.
Parker Worldwide Europe, Middle East, Africa AE United Arab Emirates, Dubai Tel: +971 4 8127100 parker.me@parker.com AT Austria, St. Florian Tel: +43 (0)7224 66201 parker.austria@parker.com AZ Azerbaijan, Baku Tel: +994 50 2233 458 parker.azerbaijan@parker.com BE/NL/LU Benelux, Hendrik Ido Ambacht Tel: +31 (0)541 585 000 parker.nl@parker.com BG Bulgaria, Sofia Tel: +359 2 980 1344 parker.bulgaria@parker.com BY Belarus, Minsk Tel: +48 (0)22 573 24 00 parker.poland@parker.com CH Switzerland, Etoy Tel: +41 (0)21 821 87 00 parker.switzerland@parker.com CZ Czech Republic, Klecany Tel: +420 284 083 111 parker.czechrepublic@parker.com DE Germany, Kaarst Tel: +49 (0)2131 4016 0 parker.germany@parker.com DK Denmark, Ballerup Tel: +45 43 56 04 00 parker.denmark@parker.com ES Spain, Madrid Tel: +34 902 330 001 parker.spain@parker.com FI Finland, Vantaa Tel: +358 (0)20 753 2500 parker.finland@parker.com FR France, Contamine s/Arve Tel: +33 (0)4 50 25 80 25 parker.france@parker.com GR Greece, Piraeus Tel: +30 210 933 6450 parker.greece@parker.com HU Hungary, Budaörs Tel: +36 23 885 470 parker.hungary@parker.com IE Ireland, Dublin Tel: +353 (0)1 466 6370 parker.ireland@parker.com IL Israel Tel: +39 02 45 19 21 parker.israel@parker.com IT Italy, Corsico (MI) Tel: +39 02 45 19 21 parker.italy@parker.com KZ Kazakhstan, Almaty Tel: +7 7273 561 000 parker.easteurope@parker.com NO Norway, Asker Tel: +47 66 75 34 00 parker.norway@parker.com PL Poland, Warsaw Tel: +48 (0)22 573 24 00 parker.poland@parker.com PT Portugal Tel: +351 22 999 7360 parker.portugal@parker.com RO Romania, Bucharest Tel: +40 21 252 1382 parker.romania@parker.com RU Russia, Moscow Tel: +7 495 645-2156 parker.russia@parker.com SE Sweden, Spånga Tel: +46 (0)8 59 79 50 00 parker.sweden@parker.com SK Slovakia, Banská Bystrica Tel: +421 484 162 252 parker.slovakia@parker.com SL Slovenia, Novo Mesto Tel: +386 7 337 6650 parker.slovenia@parker.com TR Turkey, Istanbul Tel: +90 216 4997081 parker.turkey@parker.com UA Ukraine, Kiev Tel: +48 (0)22 573 24 00 parker.poland@parker.com UK United Kingdom, Warwick Tel: +44 (0)1926 317 878 parker.uk@parker.com ZA South Africa, Kempton Park Tel: +27 (0)11 961 0700 parker.southafrica@parker.com North America CA Canada, Milton, Ontario Tel: +1 905 693 3000 US USA, Cleveland Tel: +1 216 896 3000 Asia Pacific AU Australia, Castle Hill Tel: +61 (0)2-9634 7777 CN China, Shanghai Tel: +86 21 2899 5000 HK Hong Kong Tel: +852 2428 8008 IN India, Mumbai Tel: +91 22 6513 7081-85 JP Japan, Tokyo Tel: +81 (0)3 6408 3901 KR South Korea, Seoul Tel: +82 2 559 0400 MY Malaysia, Shah Alam Tel: +60 3 7849 0800 NZ New Zealand, Mt Wellington Tel: +64 9 574 1744 SG Singapore Tel: +65 6887 6300 TH Thailand, Bangkok Tel: +662 186 7000 TW Taiwan, Taipei Tel: +886 2 2298 8987 South America AR Argentina, Buenos Aires Tel: +54 3327 44 4129 BR Brazil, Sao Jose dos Campos Tel: +55 800 727 5374 CL Chile, Santiago Tel: +56 2 623 1216 MX Mexico, Toluca Tel: +52 72 2275 4200 © 2021 Parker Hannifin Corporation. All rights reserved. Edition: May 2021/CAT/4083-Online/UK EMEA Product Information Centre Free phone: 00 800 27 27 5374 (from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA) US Product Information Centre Toll-free number: 1-800-27 27 537 www.parker.com Your local authorized Parker distributor Sensors and switches for Pressure, Temperature, Level and Flow Sensors and switches for Pressure, Temperature, Level and Flow Sensors and switches for Pressure, Temperature, Level and Flow All the instruments meet the guidelines of the European Community (EU). It is confirmed that these products are approved acc. to following standards. DIN/EN 61000-6-2 DIN/EN 61000-6-3 Note! This document and other information from Parker Hannifin GmbH, provide product or system options for further investigation by users having technical expertise. Before you select or use any product or system it is important that you analyse all aspects of your application and review the information concerning the product or system in the current product catalogue. Due to the variety of operating conditions and applications for these products or systems, the user, through his own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance and safety requirements of the application are met. The products are subject to change by Parker Hannifin GmbH at any time without notice. Technical subject to change. May 2021. © Copyright 2021, Parker Hannifin Corporation. All Rights Reserved. Parker's Motion & Control Technologies At Parker, we're guided by a relentless drive to help our customers become more productive and achieve higher levels of profitability by engineering the best systems for their requirements. It means looking at customer applications from many angles to find new ways to create value. Whatever the motion and control technology need, Parker has the experience, breadth of product and global reach to consistently deliver. No company knows more about motion and control technology than Parker. For further info call 00800 27 27 5374 Aerospace Key Markets Aftermarket services Commercial transports Engines General & business aviation Helicopters Launch vehicles Military aircraft Missiles Power generation Regional transports Unmanned aerial vehicles Key Products Control systems & actuation products Engine systems & components Fluid conveyance systems & components Fluid metering, delivery & atomization devices Fuel systems & components Fuel tank inerting systems Hydraulic systems & components Thermal management Wheels & brakes Climate Control Key Markets Agriculture Air conditioning Construction Machinery Food & beverage Industrial machinery Life sciences Oil & gas Precision cooling Process Refrigeration Transportation Key Products Accumulators Advanced actuators CO 2 controls Electronic controllers Filter driers Hand shut-off valves Heat exchangers Hose & fittings Pressure regulating valves Refrigerant distributors Safety relief valves Smart pumps Solenoid valves Thermostatic expansion valves Electromechanical Key Markets Aerospace Factory automation Life science & medical Machine tools Packaging machinery Paper machinery Plastics machinery & converting Primary metals Semiconductor & electronics Textile Wire & cable Key Products AC/DC drives & systems Electric actuators, gantry robots & slides Electrohydrostatic actuation systems Electromechanical actuation systems Human machine interface Linear motors Stepper motors, servo motors, drives & controls Structural extrusions Filtration Key Markets Aerospace Food & beverage Industrial plant & equipment Life sciences Marine Mobile equipment Oil & gas Power generation & renewable energy Process Transportation Water Purification Key Products Analytical gas generators Compressed air filters & dryers Engine air, coolant, fuel & oil filtration systems Fluid condition monitoring systems Hydraulic & lubrication filters Hydrogen, nitrogen & zero air generators Instrumentation filters Membrane & fiber filters Microfiltration Sterile air filtration Water desalination & purification filters & systems Fluid & Gas Handling Key Markets Aerial lift Agriculture Bulk chemical handling Construction machinery Food & beverage Fuel & gas delivery Industrial machinery Life sciences Marine Mining Mobile Oil & gas Renewable energy Transportation Key Products Check valves Connectors for low pressure fluid conveyance Deep sea umbilicals Diagnostic equipment Hose couplings Industrial hose Mooring systems & power cables PTFE hose & tubing Quick couplings Rubber & thermoplastic hose Tube fittings & adapters Tubing & plastic fittings Hydraulics Key Markets Aerial lift Agriculture Alternative energy Construction machinery Forestry Industrial machinery Machine tools Marine Material handling Mining Oil & gas Power generation Refuse vehicles Renewable energy Truck hydraulics Turf equipment Key Products Accumulators Cartridge valves Electrohydraulic actuators Human machine interfaces Hybrid drives Hydraulic cylinders Hydraulic motors & pumps Hydraulic systems Hydraulic valves & controls Hydrostatic steering Integrated hydraulic circuits Power take-offs Power units Rotary actuators Sensors Pneumatics Key Markets Aerospace Conveyor & material handling Factory automation Life science & medical Machine tools Packaging machinery Transportation & automotive Key Products Air preparation Brass fittings & valves Manifolds Pneumatic accessories Pneumatic actuators & grippers Pneumatic valves & controls Quick disconnects Rotary actuators Rubber & thermoplastic hose & couplings Structural extrusions Thermoplastic tubing & fittings Vacuum generators, cups & sensors Process Control Key Markets Alternative fuels Biopharmaceuticals Chemical & refining Food & beverage Marine & shipbuilding Medical & dental Microelectronics Nuclear Power Offshore oil exploration Oil & gas Pharmaceuticals Power generation Pulp & paper Steel Water/wastewater Key Products Analytical Instruments Analytical sample conditioning products & systems Chemical injection fittings & valves Fluoropolymer chemical delivery fittings, valves & pumps High purity gas delivery fittings, valves, regulators & digital flow controllers Industrial mass flow meters/ controllers Permanent no-weld tube fittings Precision industrial regulators & flow controllers Process control double block & bleeds Process control fittings, valves, regulators & manifold valves Sealing & Shielding Key Markets Aerospace Chemical processing Consumer Fluid power General industrial Information technology Life sciences Microelectronics Military Oil & gas Power generation Renewable energy Telecommunications Transportation Key Products Dynamic seals Elastomeric o-rings Electro-medical instrument design & assembly EMI shielding Extruded & precision-cut, fabricated elastomeric seals High temperature metal seals Homogeneous & inserted elastomeric shapes Medical device fabrication & assembly Metal & plastic retained composite seals Shielded optical windows Silicone tubing & extrusions Thermal management Vibration dampening Table of Contents Product overview Selection guide pressure sensors Selection guide pressure controller Pressure and temperature sensors SCP01 pressure sensor SCP02 pressure sensor SCP03 pressure sensor SCP07 pressure sensor SCP08 pressure sensor SCPSi pressure switch SCT-150 temperature sensor Volumetric flow rate sensors SCQ flow meter SCFT measurement turbine SCVF volume counter The Controller Family SCPSDi PressureController SCPSD PressureController SCTSD TemperatureController SCTSD-L combination switch SCLSD LevelController SCLTSD LevelTempController SCOTC OilTankController Accessories SCK cable SCA adapter Software ControllerWIN Installation and safety instructions EMC Compatibility with media (substances) Pressure range selection Appendix Conversion charts Index Old and new references 3 Page 4-5 6 7 9-35 12-15 16-21 22-26 27-28 29-30 31-33 34-35 36-51 38-41 42-45 46-51 52-99 54-59 60-65 66-77 78-81 82-87 88-93 94-99 100-105 100-101 102-103 104-105 106 106 106 106 107-108 107 108 108 Catalogue 4083/UK Product overview Measurement Pressure and temperature sensors SCP01 Pressure sensor for standard applications Page 12-15 SCP07 SCP02 Pressure sensor for mobile hydraulics Page 16-21 SCP08 SCP03 Pressure sensor for mobile and industrial applications Page 22-26 SCPSi Pressure sensor for safety requirements Page 27-28 SCT-150 Pressure sensor for press construction and die-casting Page 29-30 Pressure switch with IO-Link Page 31-33 Temperature sensor for high operating pressures Page 34-35 Volumetric flow rate sensors SCQ SCFT SCVF For quick flow changes Measures in both directions Page 38-41 Low loss measuring of volume flow Page 42-45 Measures different substances Measures lower volume flows (leakage measurements) Page 46-51 4 Catalogue 4083/UK Product overview Measurement, display and switching SCPSDi The Controller Family SCPSD SCTSD SCTSD-L Pressure display and monitoring Page 54-59 Page 60-65 SCLSD SCLTSD Temperature display and Temperature display and monitoring level monitoring Page 66-77 Page 78-81 SCOTC Level display and monitoring Page 82-87 Accessories SCK cable 41.5 Page 100-101 Ø14.5 ØD4 T1 T2 Level/temperature display and monitoring Page 88-93 Page 94-99 SCA adapter L1 L4 S1 X1) Page 102-103 Software ControllerWIN Page 104-105 5 Catalogue 4083/UK Pressure and temperature sensors Selection guide pressure sensors Pressurerange Order qty. Accuracy Display Output Electrical Plug Thread Wetted parts Approvals 0...bar / (psi) relative -1...bar / -14.5 (psi) relative 0...bar / (psi) absolut SCP01 10...1000 (145...14,504) 0,5 % Switching Output IO-Link 0,5...4,5 V (ratiometric 5V) 0,5...4,5 V (nominal 24V) 0...5 V 1...6 V 0...10 V 0...20 mA 4...20 mA (3-wire) 4...20 mA (2-wire) CAN M12 DIN EN 175301-803 Form A DIN Micro 9.4 AMP Superseal Deutsch DT04 4-pin Deutsch DT04 3-pin Junior Timer Cable 2m G1/4 BSPP ED G 1/4 O-ring 1/4 NPT 7/16-20 UNF 9/16-20 UNF Stainless steel/ Soft sealing Stainless steel/ Metall sealing CE Marine Safety SIL / PL · · · · · · · · · · · · · FKM · · SCP02 10...1000 (145...14,504) 50 pcs 0,5 % · · · · · · · · · · · · · · · · · FKM · SCP03 04...1000 (58...14,504) 3...24 (43,5...348) 50 pcs 0,5 % · · · · · · · · · · · · · · · · · · · · FKM · SCP07 10...600 (145...8702) SCP08 600/1000 (8702...14,504) 50 pcs 0,5 % 1 / 5 / 50 pcs 0,5 % · · · · · · · · FKM · · FKM · 6 Catalogue 4083/UK Pressure and temperature sensors Selection guide pressure controller Pressurerange Order qty. Accuracy Display Output Electrical Plug Thread Wetted parts Approvals 0...(bar) relative -1...bar / -14.5 (psi) relative 0...(bar) absolut Switching IO-Link 0,5...4,5 V (ratiometric 5V) 0,5...4,5 V (nominal 24V) 0...5 V 1...6 V 0...10 V 0...20 mA 4...20 mA (3-wire) 4...20 mA (2-wire) CAN M12 DIN EN 175301-803 Form A DIN Micro 9.4 AMP Superseal Deutsch DT04 4-pin Deutsch DT04 3-pin Junior Timer Cable 2m G1/4 BSPP ED G 1/4 O-Ring 1/4 NPT 7/16-20 UNF 9/16-20 UNF Stainless steel/ Soft sealing Stainless steel/ Metall sealing CE Marine Safety SIL / PL SCPSi · · · · NBR SCPSD SCPSDi · · · · · · · · · · · · NBR NBR · · · · · · 7 Catalogue 4083/UK Pressure and temperature sensors Certified sensors and switches for maritime applications The products designed for maritime use meet the current international approvals: ABS American Bureau of Shipping DNV Det Norske Veritas GL Germanischer Lloyd The portfolio extends from pressure sensors to electronic switches with display for pressure / level / temperature. Parker offers the chance to upgrade from mechanical to electronic measuring devices in the hydraulic system, with the following advantages: High accuracy Long lifetime Reliability Safety Comfortable functions High quality standards These certified products will enhance the safety and reliability of maritime hydraulic systems: SCP01/ SCPSD / SCPSDi / SCLTSD / SCTSD-L 8 Catalogue 4083/UK Pressure and temperature sensors Pressure and temperature sensors Device features Long-term stability Immune to interference Rugged design Dependable SensoControl® sensors feature long-term stability, interference immunity, a sturdy high-quality construction and a wide range of variants. The sensors are designed and manufactured in our own production facilities under established standards for the industrial instrumentation and control systems. This allows us to easily adapt them to customer requirements or to critical applications. We carefully consider the special requirements for automation and mobile hydraulics during the design phase. So our SensoControl® sensors are ideally suitable for the permanent series use in industrial and mobile applications. The SCP should be used when the pressure needs to be monitored reliably for long periods. In this case the optimal sensor type can be selected from different product series according to the needs of the application. Different connecting plugs, output signals and connection threads are also available. Temperature sensors The SCT temperature sensor should be used when a temperature signal is required. These are characterised by their pressure resistance up to 630 bar. Pressure sensors The housing and all parts of the pressure sensors that touch the substances are manufactured from stainless steel. This provides a large range of media tolerability. A wide range of applications is possible due to the combination of high interference immunity and high resistance to external influences (shock, vibration and temperature). The application areas are varied: form process engineering test rigs, conveying and lifting equipment, mobile hydraulics, general machine construction, pneumatic construction and hydraulic plant construction. 9 Catalogue 4083/UK Pressure and temperature sensors Overview SCP01 SCP02 SCP03 Pressure and temperature sensors Range of use Application Order code Refer to page Pressure sensor for standard applications Pressure sensor for mobile hydraulics Stainless steel measuring cell Small design High burst pressure Resistant to pressure peaks Resistant to shock and vibration Stainless steel measuring cell Small design Stainless steel housing High burst pressure ECE approval E1 High protection degree Resistant to shock and vibration General machine construction Injection-mould machines Die-casting machines Press construction Test benches Machine tool Mobile hydraulics Transport vehicles Conveyor vehicles Commercial vehicles Automotive technology Brake systems Oil pressure Test equipment and tech- nology Gearbox control SCP01-xxxx-xx-0x SCP02-xxx-xx-0xQ8 12-15 16-21 Pressure sensor for mobile and industrial applications Up to 1000 bar G1/4 DIN 3852-11 (E) Compact design Long term stability Wide temperature range -40...125°C (-40...257°F) Mobile hydraulic Transport vehicles Conveyor vehicles Commercial vehicles Automotive technology Brake systems Oil pressure Test equipment and tech- nology Gearbox control SCP03-xxx-24-05Q8 22-26 SCP07 Range of use Application Order code Refer to page Pressure sensor for safety requirements PLd SIL 2 Two inverted 4-20 mA outputs Up to 600 bar G1/4 DIN 3852-11 (E) Compact design Long term stability Wide temperature range -40...85°C (-40...185°F) Safety requirements Mobile hydraulic Cranes Suspended loads Tire presses SCP07-xxx-24-05Q8 27-28 10 Catalogue 4083/UK Pressure and temperature sensors Pressure and temperature sensors SCP08 SCPSi SCT-150 Range of use Application Order code Refer to page Pressure sensor for press con- IO-Link Pressure sensor or struction and die-casting switch Measurement of pressure even under high operating pressures 600 / 1000 bar (8702 / 14,504 psi) G1/4" 0-10 V / 4...20 mA 2-wire M12x1 / DIN Reinforced internal design Persistance against shock & vibration Made for high pressure ac- celeration High dynamic signal Pressure sensor / -switch Temperature measurement Industry 4.0-ready IO-Link 1.1 Smart Sensor Profile 2nd edition Plug & Play Compact Optimized design Adjustable via IO-link Readable via IO-Link Useable as IO-Link sensor or switch Monolithic pressure cell Resistance to pressures up to 630 bar Compact size Standard output signal Quick reaction time Press construction Die-casting Injection-mould machines Tool-making machines Power packs Special machine construc- tion Replacement for mechani- cal pressure switches Test benches Processing equipment Conveying and lifting equipment Machinery construction Pneumatic plant construc- tion Hydraulic plant construc- tion SCP08-xxxx-x4-0x 29-30 SCPSi-xxx-04-07 31-33 SCT-150-41-07 34-35 11 Catalogue 4083/UK Pressure and temperature sensors SCP01 pressure sensor Device features Small design Stainless steel measuring cell Stainless steel housing Shock and vibration proof Wide range of compatible substances High linearity Long-term stability Substance temperature -40...125 °C (-40...257°F) Pressure range up to 1000 bar (14,504 psi) High burst pressure Response time 1 ms Eroding milling Encapsulated electronics The SCP01 pressure sensor was designed to meet industrial requirements and is used in control, regulating and monitoring systems. The SCP01 is characterised by its compact design, high linearity and excellent interference immunity. It is suitable for quick control solutions because of its fast response speed. The compact stainless steel housing is good for harsh environmental conditions. All components which come into contact with the substance are made from stainless steel. This feature, combined with the welded, thin-layer measuring cell, ensure optimal compatibility with the substance. Typical application range General machine construction Injection-mould machines Die-casting machines Press construction Test benches Machine tool In order to ensure an exact pressure measurement and to avoid disturbances, an EDM hole is integrated. This minimises the cavitation of air and dirt, thus preventing the measuring cell from being influenced by pressure surges and pressure peaks. This product is ideal for permanent series usage in hydraulic applications because of its long lifespan, high accuracy, high reliability and sturdy stainless steel construction. 12 Catalogue 4083/UK Pressure and temperature sensors SCP01 pressure sensor Technical data SCP01-xxx-x4-0x (bar; G1/4" BSPP) SCP01Pressure range Pn relative 0...bar / (psi) Overload pressure* Pmax Burst pressure** Pburst 010 10 (145) 016 16 (232) 025 25 (363) 040 40 (580) 060 100 60 100 (870) (1450) 2 x Pn 4 x Pn 160 160 (2321) 250 250 (3626) 400 400 (5802) 600 600 (8702) 1000 1000 (14,504) 1.5 x Pn 2.5 x Pn SCP01-xxxxP-x5-0x (psi; 1/4 NPT) & SCP01-xxxxP-x7-0x (psi; 7/16-20 UNF) SCP01- 0150P Pressure range 150 Pn relative 0... (psi) Overload pressure* Pmax Burst pressure** Pburst * DIN EN 60770-1 / ** DIN 16086 / *** only 1/4 NPT 0250P 250 1000P 1000 3000P 3000 2 x Pn 4 x Pn 5000P 5000 9000P*** 9000 General Response time Long-term stability Load change Weight MTTFd Accuracy Non-linearity Accuracy Total error at 0 to 85 °C Temperature coefficient Zero point Output range Material Housing 1 ms < 0.2 % FS / a > 20 million Approx. 80 g > 100 years BFSL acc. to IEC 61298-2 ± 0.25 %FS Type ± 0.25 %FS Max. ± 0.5 %FS ±1 %FS Max. ± 0.2 %FS/10 K Max. ± 0.2 %FS/10 K Stainless steel1.4404 Ambient conditions Ambient temperature range -40...+85 °C / (-40...185°F) Fluid temperature range -40...+125 °C / (-40...257°F) Compensated range 0...+85 °C / (+32...185°F) Storage temperature -40...+125 °C / (-40...257°F) Vibration resistance IEC 60068-2-6: 20 g Shock resistance IEC 60068-2-27: 500 g Electrical protection Short-circuit, signal to GND, reverse polarity protection EM compatibility Disturbance emissions EN 61000-6-3 Resistance to interference EN 61000-6-2 Process connection Eroding milling 0.6 mm Tightening torque Max. 35 Nm Process connection G1/4A BSPP; DIN 3852 T11, Form E SAE 7/16 UNF Male O-ring 1/4 NPT Seal Sealing ring DIN 3869-14-FKM O-ring 8,12x1,83 FKM Parts in contact with substances FKM Stainless steel 1.4404, Stainless steel 1.4548 FKM Stainless steel 1.4404, Stainless steel 1.4548 Stainless steel 1.4404, Stainless steel 1.4548 Output signal 0...20 mA 2-wire 4...20 mA Auxiliary power V+ +9...36 VDC +9...36 VDC Max. load 50...500 50...500 (V+ - 9 V) / 20 mA (V+ - 9 V) / 20 mA 4...20 mA +9...36 VDC 50...500 (V+ - 9 V) / 20 mA 0.5...4.5 V (nom); 0...5 V; 1...6 V; 0...10 V +14...36 VDC 10 k 13 Catalogue 4083/UK Pressure and temperature sensors SCP01 pressure sensor Pin assignment Device plug DIN EN 175301-803 Form A 4-pole (old 43650) SCP01-...-06 2-wire PIN 4...20 mA 1 P-signal 2 n.c.* 3 V+ 3-wire 0/4...20 mA; 0.5...4.5 V (nom); 0...5 V; 0...10 V; 1...6 V P-signal 0 V / GND V+ n.c.* SCP01-...-06-MA 2-wire 4...20 mA V+ n.c.* P-signal 3-wire 0/4...20 mA; 0...10 V V+ 0 V / GND P-signal Protection class IP65 Circular connector M12x1 4-pole SCP01-...-07 2-wire PIN 4...20 mA 1 V+ 2 P-signal 3 n.c.* 4 Material Protection class 3-wire 0/4...20 mA; 0.5...4.5 (nom); 0...5 V; 0...10 V; 1...6 V V+ P-signal 0 V / GND n.c.** Metall plug IP67 Device plug (L-Industrial 9.4 mm) SCP01-...-0C 2-wire PIN 4...20 mA 1 P-signal 2 V+ 3 n.c.* 3-wire 0/4...20 mA; 0.5...4.5 (nom); 0...5 V; 0...10 V; 1...6 V P-signal V+ n.c.* 0 V / GND Protection class IP65 *n.c. = do not connect **n.c. = do not connect / When flying leeds are used on PIN 4, the PIN 4 has to be connected to GND. SCP01-...-x4-0x SCP01-...-x5-0x G1/4 BSPP ED ¼ NPT SCP01-...-x7-0x SAE 7/16-20UNF X1) = ED-seal X1) = O ring 8.92 x 1.83 14 Catalogue 4083/UK SCP01 pressure sensor SCP01-xxx-xx-07 S1) = SW22 SCP01-xxx-xx-06 S1) = SW22 SCP01-xxx-xx-0C S1) = SW22 Order code Pressure sensor SCP01 (bar) SCP01-xxx-xx-0x Pressure sensor SCP01 (bar) Marine SCP01-xxx-xx-0x-MA (approved by DNV/GL/ABS) Pressure range (bar) 0...10 bar 0...16 bar 0...25 bar 0...40 bar 0...60 bar 0...100 bar 0...160 bar 0...250 bar 0...400 bar 0...600 bar 0...1000 bar 010 016 025 040 060 100 160 250 400 600 1000 Output signal 0...20 mA 1 4...20 mA (3-wire) 2 4...20 mA (2-wire) 3 0...5 V* A 0,5...4,5 V (nom)* S 1...6 V* B 0...10 V 4 *Not approved for marine applications Process connection G 1/4" BSPP 4 Connection plug Circular connector M12x1 4-pole 7 Device connector DIN EN 175301-803 Form A 4-pole 6 Cevice plug industrial micro DIN 9.4 mm C Pressure sensor SCP01 (psi) SCP01-xxxxP-xx-0xQ8 Pressure range (psi) 0...150 psi 0...250 psi 0...1000 psi 0...3000 psi 0...5000 psi 0...9000 psi 0150P 0250P 1000P 3000P 5000P 9000P Output signal 4...20 mA (3-wire) 2 4...20 mA (2-wire) 3 0...10 V 4 Process connection SAE 7/16 UNF Male O ring (Pn max. = 400 bar) 7 1/4 NPT (Pn max. = 600 bar) 5 Connecting plug Circular connector M12x1 4-pole Order quantity 15Q8: Multiple of 50 pcs. 7 Catalogue 4083/UK Pressure and temperature sensors Pressure and temperature sensors SCP02 pressure sensor Device features Small design Stainless steel measuring cell Stainless steel housing Shock and vibration proof High protection degree E1 road approval Substance temperature -40...150 °C (-40...302°F) Up to 1000 bar (14,504 psi) 1 ms Up to 36-V wiring systems The SCP02 was designed specifically for the use in mobile working machines. The SCP02 has e1-approval and is manufactured with state of the art production methods according to ISO/TS 16949. The shock and vibration resistance, the EMC characteristics, the power supply as well as the extended temperature range all were designed for this application type. The SCP02 is suitable for quick control solutions because of its fast response speed. The compact stainless steel housing with the plastic connector allows for use in harsh environmental conditions such as those in mobile hydraulics. The components which come into contact with the substance are made from stainless steel (1.4548). This feature, combined with the welded, thin-layer measuring cell, ensures optimal compatibility with the substance. An EDM hole has been added so that you get a precise, interference-free pressure measurement. This minimises the cavitation of air and dirt, thus preventing the measuring cell from being influenced by pressure surges and pressure peaks. Typical application range Mobile hydraulics Transport vehicles Conveyor vehicles Commercial vehicles Automotive technology Brake systems Oil pressure Test equipment and technology Gearbox control 16 Catalogue 4083/UK Pressure and temperature sensors SCP02 pressure sensor Technical data SCP02- Pressure range Pn relative 0... bar / (psi) Overload pressure* Pmax Burst pressure** Pburst * DIN EN 60770-1 ** DIN 16086 010 10 (145) 025 25 (363) 035/040 40 (508/580) 060 60 (870) 100 160 100 160 (1450) (2321) 2 x Pn 4 x Pn 250 250 (3626) 400 400 (5802) 500 500 (7252) 600 600 (8702) 1000 1000 (14,504) 1.5 x Pn 2.5 x Pn General Response time Long-term stability Load change Weight MTTFd Accuracy Linearity, pressure hysteresis and reproducibility Complete accuracy Temperature coefficient Zero point Output range Material Housing Electrical plug 1 ms < 0.2 % FS / a > 100 million Approx. 55 g > 100 years 0.5 %FS 1.0 %FS (0...+80 °C) 1.5 %FS (-25...+100 °C) 2.5 %FS (-40...+125 °C) Max. ± 0.2 %FS/10 K Max. ± 0.2 %FS/10 K EN/DIN 1.4301 Plastic PBT-GF30 Ultradur B4300 G6 black Ambient conditions Ambient temperature range -40...+125 °C / (-40...257°F) Fluid temperature range -40...+150 °C / (-40...284°F) Storage temperature -40...+125 °C / (-40...257°F) Vibration resistance IEC 60068-2-6: 20 g Shock resistance IEC 60068-2-27: 500 g Electrical protection Short circuit, signal against GND/0V and protection against polarity reversal (not with ratiometric output) EM compatibility Disturbance emissions EN 61000-6-3 Resistance to interference EN 61000-6-2 Process connection Eroding milling 0.6 mm Tightening torque Max. 35 Nm Process connection Seal Parts in contact with substances G1/4A BSPP; DIN 3852 T11, Form E Sealing ring DIN 3869-14-FKM EN/DIN 1.4548 / FKM SAE-4: 7/16-20 UNF O-ring O-ring FKM EN/DIN 1.4548 / FKM SAE 6: 9/16-18 UNF O-ring O-ring FKM EN/DIN 1.4548 / FKM G1/4 DIN ISO 228-1 O-ring O-ring FKM EN/DIN 1.4548 / FKM 1/4 NPT EN/DIN 1.4548 Max. pressure range Pn 1000 bar / (14,504 psi) 400 bar / (5,802 psi) 400 bar / (5,802 psi) 600 bar / (8,702 psi) 600 bar / (8,702 psi) Output signal P signal Auxiliary power V+ Load (Ohm) 2-wire 4...20 mA +9...36 VDC 50...500 (V+ - 9 V) / 20 mA 0...5 V; 1...6 V 0.5...4.5 V nom. +9...36 VDC 10 k 0...10 V +14...36 VDC 10 k 0.5...4.5 V ratiometric 5 V 10 k 17 Catalogue 4083/UK Pressure and temperature sensors SCP02 pressure sensor Pin assignment AMP Superseal 1.5 SCP02-xxx-xx-0A PIN 2-wire 4...20 mA 1 P-signal 2 n.c.* 3 V+ Material Protection class 0...5 V; 1...6 V; 0.5...4.5 V 0.5...4.5 V nom.; 0...10 V ratiometric 0 V / GND 0 V / GND P-signal P-signal V+ V+ Plastic PBT-GF30 Ultradur B4300 G6 black IP67 DT04-4P SCP02-xxx-xx-0D DT04-3P SCP02-xxx-xx-0E 2 m fixed cable SCP02-xxx-xx-00 PIN 2-wire 4...20 mA 1 V+ 2 P-signal 3 n.c.* 4 n.c.* Material Protection class 0...5 V; 1...6 V; 0.5...4.5 V 0.5...4.5 V nom.; 0...10 V ratiometric V+ 0 V / GND V+ 0 V / GND P-signal P-signal n.c.* n.c.* Plastic PBT-GF30 Ultradur B4300 G6 black IP67 PIN 2-wire 4...20 mA A V+ B n.c.* C P-signal Material Protection class 0...5 V; 1...6 V; 0.5...4.5 V 0.5...4.5 V nom.; 0...10 V ratiometric V+ P-signal V+ P-signal 0 V / GND 0 V / GND Plastic PBT-GF30 Ultradur B4300 G6 black IP67 2-wire 4...20 mA 0...5 V; 1...6 V 0.5...4.5 V 0.5...4.5 V nom.; 0...10 V ratiometric bn black V+ n.c.* V+ P-signal V+ P-signal blue P signal 0 V / GND 0 V / GND Material Plastic PBT-GF30 Ultradur B4300 G6 black Protection class IP69k bn = brown-braun / bk = black-schwarz / bu = blue-blau *n.c. = do not connect 18 Catalogue 4083/UK Pressure and temperature sensors SCP02 pressure sensor Pin assignment M12x1 SCP02-xxx-xx-x5 PIN 2-wire 4...20 mA 1 V+ 2 P-signal 3 n.c.* 4 n.c.* 5 n.c.* Material Protection class *n.c. = do not connect 0...5 V; 1...6 V 0.5...4.5V ratiometric CAN-Assignment 0.5...4.5 V nom.; 0...10 V V+ P-signal 0 V / GND V+ P-signal 0 V / GND CAN shield, PE +UB, +24 VDC GND, 0 V n.c.* n.c.* CAN_H, CAN+ n.c.* n.c.* CAN_L, CAN- Plastic PBT-GF30 Ultradur B4300 G6 black IP67 SCP02-xxx-xx-0A AMP Superseal SCP02-xxx-xx-0D DT04-4P SCP02-xxx-xx-0E DT04-3P SCP02-xxx-xx-05 M12x1 SCP02-xxx-xx-00 Stationary cable (2 m) 19 Catalogue 4083/UK Pressure and temperature sensors SCP02 pressure sensor SCP02-xxx-x4-0x G 1/4, DIN 3852 T 11 (Form E) SCP02-xxx-x8-0x G1/4 O-ring SCP02-xxx-x5-0x 1/4 NPT X1) = ED-seal SCP02-xxx-x7-0x SAE 04 - O-ring X1) = O-ring SCP02-xxx-x6-0x SAE 06 - O-ring X1) = O-ring 8.92x1.83 SCP02-xxx-xx-0x M12x1 X1) = O-ring 11.89x1.98 S1) = SW22 20 Catalogue 4083/UK Pressure and temperature sensors SCP02 pressure sensor Order code Connection cable and single plug Pressure sensor SCP02 Pressure range 0...10 bar 0...25 bar 0...35 bar 0...40 bar 0...60 bar 0...100 bar 0...160 bar 0...250 bar 0...400 bar 0...500 bar 0...600 bar 0...1000 bar SCP02-xxxx-xx-0xQ8 010 025 035 040 060 100 160 250 400 500 600 1000 Output signal 4...20 mA (2-wire) 3 4...20 mA (3-wire) 2 0...10 V 4 0...5 V A 1...6 V B 0.5...4.5 V (ratiometric) R 0.5...4.5 V (nom.) S CAN K Process connection G1/4 BSPP 4 1/4 NPT (Pn max. = 600 bar) 5 9/16-18 UNF, SAE 6 O-ring (Pn max. = 400 bar) 6 7/16-20 UNF SAE-4 O-ring (Pn max. = 400 bar) 7 G1/4 O-ring (Pn max. = 600 bar) 8 Connection cable, assembled (open cable end) Cable length (m) 2 m 5 m 10 m Connecting plug M12 cable jack; straight M12 cable jack; 90° angled Single connector M12 cable jack; straight M12 cable jack; 90° angled Order example 50x SCP02-400-34-05Q8 50 Single sensors Pressure range 400 bar Output signal 4 to 20 mA (2-wire) G1/4 BSPP M12 connecting plug 5-pole SCK-400-xx-xx 02 05 10 45 55 SCK-145 SCK-155 Connecting plug Stationary cable 1 m 0 Circular connector M12x1 5-pole 5 Device plug AMP Superseal A Device plug DT04 4-pole D Device plug DT04 3 pole E Order quantity Q8: Multiple of 50 pcs. 21 Catalogue 4083/UK Pressure and temperature sensors SCP03 pressure sensor Device features Monolithic design No internal seal No material mix No weld seam High media compatibility Measuring range from -1 to 1000 bar Negative pressure resistant Many connections The SCP03 is a pressure sensor for liquid and gaseous media. The digitally calibrated piezoresistive measuring cell detects negative pressures from -1 bar up to high pressures of 1000 bar. The pressure connection in contact with the medium has a monolithic design. This eliminates the need for internal seals and weld seams. A mix of materials is avoided. The resulting low permeability in combination with the stainless steel results in broad media resistance. Typical application range Mobile hydraulics Transport vehicles Conveyor vehicles Commercial vehicles Automotive technology Brake systems Oil pressure Test equipment and technology Gearbox control The compact stainless-steel housing allows space-saving use, even in harsh environmental conditions. With its wide range of pressure ranges, output signals and connectors, the SCP03 can be used in industrial and mobile applications. The packaging variant optimized for OEM's is environmentally friendly, cost-optimized and facilitates handling. 22 Catalogue 4083/UK Pressure and temperature sensors SCP03 pressure sensor Technical data SCP03- Pressure range -1 ... bar Pn relative (-14.5 ... psi) 004R 3 (43,5) 010R 9 (130) 025R 24 (348) SCP03- 004 010 025 035 040 060 100 250 400 500 600 1000 Pressure range 4 10 25 35 40 60 100 250 400 500 600 1000 Pn relative 0 ... bar / (psi) (58) (145) (363) (500) (580) (870) (1450) (3626) (5800) (7300) (8702) (14,503) Overload pressure Pmax DIN EN 60770-1 (bar) 2 x Pn relative Burst pressure Pburst DIN EN 60770-1 (bar) relative 3 x Pn General Response time Load change Material Housing Material Electr. Connector Weight Accuracy parameter Non-linearity + Hysteresis + Repeatability Long-term stability Overall Accuracy @ 25°C @ 0°C...+85°C 1 ms > 100 million EN/DIN 1.4301 PBT-GF30 black Approx. 80 g 0.3 %FS 1.0 %FS / year < 10 bar (145 psi) 0.5 %FS 2 %FS 10 bar (145 psi) 0.5 %FS 1 %FS Ambient conditions Media temperature Operation / Ambient temperature Storage temperature Vibration resistance Shock resistance Conformity CE RoHs MTTFd -40...+125 °C / (-40...257°F) -40...+105 °C / (-40...221°F) -40...+125 °C / (-40...257°F) IEC 60068-2-6: 20 g IEC 60068-2-27: 100 g EN 61326-1 EN61326-3-1 Yes > 100 years Process connection Seal G1/4A BSPP; DIN 3852 T11, Form E DIN 3869-14-FKM SAE-4: 7/16-20 UNF O-ring FKM SAE 6: 9/16-18 UNF O-ring FKM G1/4 DIN ISO 228-1 O-ring FKM 1/4 NPT Wetted parts EN/DIN 1.4404 / FKM EN/DIN 1.4404 / FKM EN/DIN 1.4404 / FKM EN/DIN 1.4404 / FKM EN/DIN 1.4404 23 Catalogue 4083/UK Pressure and temperature sensors SCP03 pressure sensor Pin assignment Output signal (2 wire) 0...20 mA 0.5...4.5 V 1...6 V 4....20 mA 4...20 mA 0...5 V 0...10 V Supply Voltage V+ Load max Overvoltage 10...32 VDC 12...32 VDC (V+ - 10V) / 20 mA [k] 8...32 VDC 50 VDC 12...32 VDC 4.7 [k] Short circuit Yes Rever polarity Yes Signal on GND / V+ Yes M12x1 4-pole Pin 1 Pin 2 V+ P-Signal Pin 3 n.c. 0 V / GND Pin 4 n.c. n.c. IP 67 DIN EN 175301-803 Form A 4-pole (old 43650) Pin 1 P-Signal Pin 2 n.c 0 V / GND Pin 3 V+ Pin 4 / GND n.c IP 65 AMP Superseal 1.5 Pin 1 P-Signal 0 V / GND Pin 2 n.c P-Signal Pin 3 V+ IP 65 DT04-4P Pin 1 Pin 2 P-Signal V+ 0 V / GND Pin 3 n.c P-Signal Pin 4 / GND n.c IP 65 DT04-3P A B n.c V+ P-Signal C P-Signal 0 V / GND IP 65 Junior Timer Pin 1 P-Signal 0 V / GND Pin 2 n.c P-Signal Pin 3 V+ IP 65 Cable Bn Black V+ P-Signal Blue n.c 0 V / GND IP 69K 0.5...4.5 V ratio. 5 V ±10% 24 Catalogue 4083/UK Pressure and temperature sensors SCP03 pressure sensor Pin assignment SCP03-...-..-07 M12 4P SCP03-...-..-06 DIN EN 175301-803 Form A SCP03-...-..-0D DT04 4P SCP03-...-..-0E DT04 3P SCP03-...-..-0A Superseal SCP03-...-..-0J Junior Timer 3P SCP03-...-..-00 Cable SCP03-xxx-x4-0x G 1/4, DIN 3852 T 11 (Form E) SCP03-xxx-x8-0x G 1/4 O-ring SCP03-xxx-x5-0x 1/4 NPT X1) = ED-seal SCP03-xxx-x6-0x SAE 06 - O-ring X1) = O-ring SCP03-xxx-x7-0x SAE 04 - O-ring 25 Catalogue 4083/UK Pressure and temperature sensors SCP03 pressure sensor Order code Pressure sensor SCP03 Pressure range -1...3 bar -1...9 bar -1...24 bar 0...4 bar 0...10 bar 0...25 bar 0...35 bar 0...60 bar 0...100 bar 0...250 bar 0...400 bar 0...500 bar 0...600 bar 0...1000 bar Order example SCP03-xxx-xx-0xQ8 004R 010R 025R 004 010 025 035 060 100 250 400 500 600 1000 150x SCP03-400-34-07Q8 150 Single sensors (multiple of 50's) Pressure range 0...400 bar Output signal 4 to 20 mA (2-wire) G1/4 BSPP M12 connecting plug 4-pole Output signal 0...20 mA 1 4...20 mA (2-wire) 3 4...20 mA (3-wire) 2 0...10 V 4 0...5 V A 1...6 V B 0.5...4.5 V (ratiometric) R 0.5...4.5 V (nom.) S Process connection G1/4 BSPP 4 1/4 NPT (Pn max. = 600 bar) 5 9/16-18 UNF, SAE 6 O-ring (Pn max. = 400 bar) 6 7/16-20 UNF SAE-4 O-ring (Pn max. = 400 bar) 7 G1/4 O-ring (Pn max. = 600 bar) 8 Connecting plug Device connector DIN EN 175301-803 Form A 4-pole 6 Circular connector M12x1 4-pole 7 Stationary cable 2 m 0 Device plug AMP Superseal A Device plug DT04 4 pole D Device plug DT04 3 pole E Junior Timer 3-pole J Order quantity Minimum order qty: Q8: Multiple of 50 pcs. 26 Catalogue 4083/UK Pressure and temperature sensors Pressure sensor SCP07 Device features For safety requirements PLd SIL 2 Two inverted 4-20 mA outputs Up to 600 bar (8,702 psi) G1/4 DIN 3852-11 (E) Compact design Long term stability Wide temperature range -40...85°C (-40...185°F) The SCP07 is a safety-related pressure transmitter and can be used in applications that require a Performance Level d according to EN ISO13849 or a SIL 2 according to IEC61508. The SCP07 supervises the signals of its measurement cell and convert the pressure in two inverted 4-20 mA output signals. The control unit can monitor the safetyrelated functionality and the electrical connectivity of the SCP07. Typical application range Mobile hydraulic Cranes Suspended loads Tire presses 27 Catalogue 4083/UK Pressure and temperature sensors Pressure sensor SCP07 Technical data SCP07Pressure range Pn 0... bar / (psi) relative Overload pressure Pmax DIN EN 60770-1 bar / (psi) relative Burst pressure Pburst 60770-1 bar / (psi) relative 010 10 (145) 50 (725) 250 (3626) 025 25 (363) 50 (725) 250 (3626) 060 60 (870) 200 (2901) 1000 (14,504) 100 100 (1450) 200 (2901) 1000 (14,504) 250 250 (3626) 500 (7252) 2500 (36,259) 400 400 (5802) 800 (11,603) 4000 (58,015) 600 600 (8702) 1600 (23,206) >4000 (>58,015) General Response time Load change Material Housing Weight Process Connection Material Material diaphragm Wetted parts Seal Installation torque Ambient Conditions Media temperature Operation / Ambient temperature Storage temperature Vibration Shock Conformity CE E1 Accuracy Parameter Non-linearity + Hysteresis+Repeatability Long-term stability Overall Accuracy @ -40°C...-25°C @ -25°C...0°C @ 0...85°C Safety classification IEC 61508:2010 Safety-related subsystem Hardware architecture HFT SFF (incl. control unit) PFH EN ISO 13849-1:2010 Category DC (incl. control unit) CCF MTTFD 1 ms >100 million Stainless steel 1.4301 Approx. 50 g G1/4, DIN 3852 T11 (E) Stainless steel 1.4548 Stainless steel 1.4548 FKM Stainless steel 1.4548 ED Type: FKM Max. 35 Nm -40...125°C / (-40...257°F) -40...85°C / (-40...185°F) -40...100°C / (-40...212°F) IEC 60068-2-6 :20g IEC 60068-2-27 :500g EN 61326-1, EN 61326-3-1 All vehicle types with +12/24 V and battery (-) at the chassis 0,5 %FS 0,2 %FS / year 2,5 %FS 1,5 %FS 1 %FS SIL 2 Type B 1oo1 0 95 % 8,4 *10E-9 PLd 2 93,8 % 70 >100 years MTEBlFec(StNric29a5l 0C0o) nnection 420,7 years Output signal 4...20 mA / 20...4 mA Supply voltage V+ Loadmax Protection 9...32 VDC ripple @50HZ 10 % (V+-5.5 V) / 0,02 A [] Overvoltage yes Short circuit yes Reverse polarity yes M12x1 Signal on GND/V+ yes Protection class IEC 60529 IP67 (mounted connector) Material PBT-GF30 Pin 1 Pin 2 V+ 20...4 mA Pin 3 GND Pin 4 4...20 mA Pin 5 Do not connect! Signal 20 mA UNDEFINED Output 2 Output 1 4 mA UNDEFINED SAFE STATE 0 %FS Pressure 100 %FS Order code Pressure sensor SCP07 SCP07-xxx-24-05Q8 Pressure range 0...10 bar................................................................-010 0...25 bar................................................................-025 0...60 bar................................................................-060 0...100 bar..............................................................-100 0...250 bar..............................................................-250 0...400 bar..............................................................-400 0...600 bar..............................................................-600 Order quantity Q8: Multiple of 50 pcs. 28 Catalogue 4083/UK Pressure and temperature sensors Pressure sensor SCP08 Device features 600 / 1000 bar (8,702 / 14,504 psi) G1/4" 0-10V / 4...20mA 2-wire M12x1 / DIN Reinforced internal design Persistance against shock & vibration Made for high pressure acceleration High dynamic signal Particularly in die-casting applications the controlling for the piston requires a high dynamic pressure sensor. During this fast, high energetic process the components are stressed by shock, vibration and pressure acceleration. Typical applications Press construction Die-casting The pressure sensor SCP08 measures the pressure via a special designed measurement cell and has a high adapted overload pressure to withstand the pressure peaks. To avoid abrasion of the cell due to Diesel or similar effects, the process connection is protected by an adjusted drilling. The dimension of the drilling still guaranties an instantaneous pressure response. To increase shock and vibration resistance, the relevant internal components are covered and reinforced. The speed of the sensor influences directly the quality of the production process. The unique combination of accuracy, durability and high dynamic response makes the SCP08 ideal for the requirements of die-casting applications. 29 Catalogue 4083/UK Pressure and temperature sensors Pressure sensor SCP08 Technical data SCP08Pressure range Pn 0... bar / (psi) relative Overload pressure Pmax bar / (psi) relative Burst pressure Pburst bar / (psi) relative 600 600 (8702) 1200 (17,405) 1800 (26,107) 1000 1000 (14,504) 1500 (21,756) 2000 (29,008) General Response time 0...10 V 0,3 ms 4...20 mA 2-Leiter 0,5 ms* Load change >10 million. Material Housing Stainless steel 304 Weight Approx. 80 g Ambient Conditions Media temperature -40...125°C / (-40...257°F) Operation- / Ambient temperature -40 to 105°C / (-40...221°F) Storage temperature -40 to 125°C / (-40...257°F) Vibration 20 g rms Shock 1 m on concrete Conformity CE yes Overall Accuracy @ RT *1 0,5 %FS @ -10°C...85°C *1 *2 2 %FS @ -40...105°C *1 *2 2,5 %FS Long-term stability 0,2 %FS / year *1 incl. Non-linearity + Hysteresis + Offset + Gain *2 incl. Repeatability + Temperature effects RT = Room Temperature 20°C Process Connection Thread G1/4, DIN 3852 T11 (E) Eroding milling 0,6 mm Volume measured <1 mm3 Seal ED Type: FKM Material Stainless steel 17-4 PH Material diaphragm Stainless steel 17-4 PH Wetted parts FKM Stainless steel 17-4 PH Installation Installation torque Max. 35 Nm General no restriction Recommended preventive activities to avoid air inclusion: · Bleed air · Installation with Process connection on top *with 2 m cable Output signal 0...10 V 4...20 mA 2-wire Supply voltage V+ Loadmax Pro- Overvoltage tection Short circuit 12...32 VDC 10...32 VDC 10 k (V+ -10 V) / 20 mA 36 signal on GND/V+ yes Reverse polarity yes Signal on GND/V+ yes M12x1 Protection class IP67 (mounted connector) 0...10 V 4...20 mA 2-wire Pin 1 Pin 2 V+ P-signal V+ P-signal Pin 3 V- Pin 4 DIN EN 175301-803 Form A Protection class (mounted connector)) IP65 0...10 V Pin 1 Pin 2 Pin 3 V+ VP-signal Pin 4 4...20 mA 2-wire V+ P-signal Binder S763-4 EN 175301-803-A 5 4 22 8 6 1 2 SW 22 FKM seal Snubber 0,6 G1/4 Order code 1 2 22 SW 22 FKM seal Snubber 0,6 G1/4 Pressure sensor SCP-08 4...20 mA; 2-wire SCP08-xxxx-x4-0x ENTGRATEN UND SCHARFE KANTEN BRECHEN ZEICHNUNG Pressure range (bar) 0...600 bar 0...1000 bar ENTGRATEN UND SCHARFE KANTEN BRECHEN Datum Name Signum BENENNUNG: Bearb. 12.07.2018 Scholz Gepr. 600 Freigeg. ZEICHNUNG NICHT SKALIEREN SC Toleranzen: DIN ISO 1000WERKSTOFF: ZEICHNUNGSNR. Output signal 4...20 mA (2-wire) 1 Pinbeleg. angepasst 18.09.18 Scholz Rev. Datum Änderung Name Datum Name Signum BENENNUNG: MASSSTAB: Bearb. 12.07.2018 Scholz Gepr. SCP08-1000-44-0 Freigeg. 3 0...10V WERKSTOFF: 1 Pinbeleg. angepasst 18.09.18 Scholz Rev. Änderung Connecting plug Datum Name 4 ZEICHNUNGSNR. MASSSTAB: 94052097_1 BLATT 1 VON 1 DIN EN 175301-803 Form A 4 pole 6 M12x1 4 pole 7 Order quantity Q2: Multiple of 5 pcs. Q8: Multiple of 50 pcs. 30 Catalogue 4083/UK Pressure and temperature sensors SCPSi pressure switch Device features Pressure sensor / -switch Temperature measurement Industry 4.0-ready IO-Link 1.1 Smart Sensor Profile 2nd edition Plug & Play Compact Optimized design Adjustable via IO-Link Readable via IO-Link Useable as IO-Link sensor or switch Monolithic pressure cell The fully electronic pressure switch SCPSi is adjustable and free from susceptible mechanical and moving components. nation with the smart functions & setting options, opens up new possibilities in machine design for the machine designer, with considerable savings potential. With its digital interface and smart functions, the SCPSi iis future-proof for the increasing demands of automation solutions. The 2 switching outputs are individually and safely parameterized from the machine control system via the standardized digital IO-Link interface (IEC 61131-9). This replaces manual programming and the commissioning phase is considerably shortened. Devices can be replaced during operation without the need for reparameterization. In order to react promptly to machine status changes or process adjustments, the re-parameterization is carried out during operation. As an alternative to the switching functions, diagnostic values, process data and status messages are recorded directly via IO-Link and enable subsequent more complex analyses. Via the integrated temperature measurement of the pressure measuring cell, the media or ambient temperature is recorded. The compact stainless steel housing allows space-saving use, even in harsh environments. The proven stainless steel measuring cell with the wide pressure range (from -1 up to 600 bar) allows a wide range of applications for liquid and gaseous media. The media-contacting pressure connection with the pressure measuring cell is monolithically manufactured from a stainless steel without welds and sets new standards in media compatibility and pressure resistance. The packaging variant optimized for OEM`s is environmentally friendly, cost-optimized and facilitates handling. Application examples Injection-mould machines Tool-making machines Power packs Special machine construction Replacement for mechanical pressure switches IO-Link replaces time-consuming manual programming and eliminates the need for a sensitive key display with the manufacturer-dependent setting menu. This more compact, more resistant design without key display, in combi- 31 Catalogue 4083/UK Pressure and temperature sensors SCPSi pressure switch Technical data SCPSi Pressure range Pn vacuum tight / relative Pn Overload pressure relative Pmax Burst pressure relative Pburst Wetted parts Set point SP Range Reset point rP Range Steps / Incremental Smallest hysteresis (SP-rP) & (FH-FL) bar (psi) bar (psi) bar (psi) mbar bar 001 004 010 025 060 100 250 400 600 -1...1 -1...4 -1...10 -1...25 0...60 0...100 0...250 0...400 0...600 (-14...14) (-14...58) (14...145) (-14...362) (0...870) (0...1450) (0...3625) (0...5801) (0...8702) 6 10 030 80 200 300 750 1200 1400 (87) (145) (435) (1160) (2900) (4351) (10877) (17404) (20305) 9 (130) 15 (217) 100 (1450) 150 (2175) 500 800 1000 2000 2200 (7251) (11603) (14503) (29007) (31908) 1.4542 (17-4PH); 1.4548; FKM Monolitisch 316L; FKM 1 - 100 % 0 - 99 % 0,1 1 1 1 10 10 10 100 100 0,001 0,01 0,01 0,01 0,1 0,1 0,1 1 1 Genral Overall Accuracy @ RT [*1] Min. pressure cycles Material housing Weight Conformity RoHS CE UKCA Process connection Thread Seal Installation torque Ambient conditions Media temperature Operation / Ambient temperature Storage temperature Vibration Shock MTTFd Accuracy @ -40°C...-25°C @ -25...0°C @ 0...85°C Temperature signal Output Short circuit Resolution Accuracy t0,9 Protection Overvoltage Short circuit Reverse polarity Signal on GND/V+ Factory setting SP1 / rP1 SP2 / rP2 0,5 %FS > 100 million Stainless steel 1.4404 approx. 80 g 2011/65/EU, 2015/863 Yes Yes G1/4, DIN 3852 T11 (E) ED type: FKM Max. 35 Nm -25 to 85 °C (-13 to 185°F) -25 to 85 ° C (-13 to 185°F) -40 to 85 °C (-40 to 185°F) DIN EN 60068-2-6, 20 g DIN EN 60068-2-27, 500 g >100 year 2,5 %FS 1,5 %FS 1 %FS Via IO-Link -40 to 125 °C 1 K ± 10°K 80 sek. 70 V yes yes yes 40 / 60% FS; Hno 30 / 70% FS; Hno Electronic Connectivity Power supply voltage V(+) Connector Consumption 18...30VDC M12 < 15 mA @ 24V Output 2 switching outputs, NPN / PNP, 1 IO-Link output Switch current Max. switch frequency Response time IO-Link Interface Max. 200mA 200 Hz 3 ms Revision IO-Link V1.1 Process Data Variable; Device Identification; Device Diagnosis Min. process cycle time Transmission type Profile 4 ms COM2, 38.4kBaud Smart Sensor Profile 2nd Edition v1.1.2 SIO-Mode yes Master port type A Process data analogue (in Pa) 2 Byte Process data 1 Byte scaling factor Process data binary 1 byte SDCI Standard IEC 61131-9 Vendor ID 271 / 10f (hex) Device IODD https://ioddfinder.io-link.com/#/ M12x1 Protection class (mounted connector) IP67 Pin 1 Pin 2 Pin 3 Pin 4 V(+) S2 out 0V / GND S1 out / IO-Link 32 Catalogue 4083/UK Pressure and temperature sensors SCPSi pressure switch Order code SCPSi Pressure switch Druckbereich 0...001 bar 0...004 bar 0...010 bar 0...025 bar 0...060 bar 0...100 bar 0...250 bar 0...400 bar 0...600 bar SCPSi-xxx-04-07 001 004 010 025 060 100 250 400 600 33 Catalogue 4083/UK Pressure and temperature sensors SCT-150 temperature sensor Device features Withstands pressures up to 630 bar (9137psi) Compact design Heavy-duty steel housing Simple installation -25 °C...+100 °C (-13...212°F) The SCT electronic temperature sensor features a compact design and high pressure resistance. The SCT is used where temperatures have to be measured under high pressure and a compact housing is necessary. With its pressure resistance up to 630 bar, the SCT temperature sensor is well suited for hydraulic applications. Application examples Test benches Processing equipment Conveying and lifting equipment Machine construction Pneumatic plant construction Hydraulic plant construction It can be used for precise and quick temperature measurements. The SCT series temperature sensors are compatible with the SCE panel meters. So both the hydraulic pressure and the substance temperature can be measured, checked and evaluated. 34 Catalogue 4083/UK Pressure and temperature sensors SCT-150 temperature sensor Technical data Input Measuring range Accuracy Response time Output OutputT (scaling for output!) Load Process connection G1/4A ED or M10x1 Seal Housing Operating pressure Pn Parts in contact with substances Ambient conditions Power supply V+ Current consumption Ambient temperature range Fluid temperature range Storage temperature Electrical connection Protection degree -25...+100 °C / (-13...212°F) < ± 7 K 0.9 = 13.5 0...20 mA = -50...+125 °C 250 FKM Steel C15K/CF 630 bar / (9137 psi) Steel C15K/CF, FKM +11...+24 VDC < 30 mA -20...+70 °C / (-4...158°F) -25...+125 °C / (-13...257°F) -25...+80 °C / (-13...176°F) M12x1 IP67 SCT-150-xx-07 Circular connector M12x1; 4-pole S1) = 19 SCT-150-41-07 G1/4A ED Pin assignment Cable Assignment 1 V+ 2 T-signal 3 0 V / GND 4 n.c.* *n.c. = do not connect L1) = 61 X1) = ED seal SCT-150-14-07 M10x1 Order code Temperature sensor G1/4 Temperature sensor M10x1 SCT-150-41-07 SCT-150-14-07 X1) = O-ring 35 Catalogue 4083/UK Volumetric flow rate sensors Volumetric flow rate sensors Device features Different measurement techniques Quick Not dependent on viscosity Without loss Many measurement ranges Analogue output signal M12 connecting plug 24 VDC The flow sensors used in SensoControl® provide accurate volume flow information in hydraulic systems (e.g. in testing equipment). The sensors deliver a output signal that is proportional to the volumetric flow rate for further processing to an electronic system. They are compatible with conventional, well-known standards. M12 connecting plug 24 VDC 0/4 to 20 mA The volumetric flow rate can be easily displayed when using the SCE-020 panel meter. In order to meet the many different application requirements, three different measuring principles are available: SCVF geared counter SCFT turbine SCQ spring/piston The volumetric flow rate sensors are used in control, regulation or monitoring systems where analogue signals are needed to capture the volume flow. 36 Catalogue 4083/UK Volumetric flow rate sensors Overview SCQ SCFT SCVF Range of use Applications For quick flow changes Measures in both directions Low loss measuring of volume flow Measures different substances Measures lower volume flows (leakage measurements) Response speed 2 ms Reverse operation Wide viscosity range Compact size Up to 420 bar (6092 psi) Response speed 50 ms Many measurement ranges Low flow resistance Up to 800 l/min Up to 420 bar (6092 psi) Very wide measurement range Not dependent on viscosity Up to 400 bar (6092 psi) Test rigs General machine construction Hydraulic plant construction Order code Refer to page SCQ-xxx-10-07 37-41 SCFT-xxx-22-07 42-45 SCVF-xxx-10-07 46-51 Volumetric flow rate sensors 37 Catalogue 4083/UK Volumetric flow rate sensors SCQ flow meter Device features Measurement principle Spring/piston principle Response time 2 ms Measurement in both directions Wide viscosity range Compact design Withstands pressures up to 420 bar (6092 psi) Function The piston (K) is moved due to a flow from A to B or from B to A. In the idle state, the spring (F) and the piston (K) are in equilibrium. The delta (S) is proportional to the flow and is converted to a value through the built-in electronics. Through the change in direction of the piston (B to A), the flow direction can be indicated. (e.g. -45.8 l/min) The reaction time of the piston movement is less than 2 ms. Application When working with high-pressure hydraulics, it is very important to be able to quickly detect the flow rate. Installation with a connection block permits the combined measurement of p, T and Q. Rapid assembly of the SCQs is achieved with an in-line adaptor for tube or hose installation. Use under extreme conditions (such as high load changes or rapid pressure increases) is possible because of the sturdy construction. The SCQ is the perfect solution when recording highly dynamic volume flow changes. Rapid load changes, which can cause damage for example in valves and pumps, can be safely detected. Due to its unique measurement process, the SCQ can capture volume flow in both directions. SCQ measurement principle 38 Catalogue 4083/UK Volumetric flow rate sensors SCQ flow meter Technical data SCQMeasuring range QN Qmax Substance connection Weight (g) Accuracy Deviation from characteristic curve Response time Thermal drift Repeat accuracy Resistance to pressure Pressure range Operating pressure Pn Overload pressure Pmax Pressure drop P (bar) @ (FS) Material Housing Seal Parts in contact with substances Ambient conditions Operating temperature Storage temperature Tmax Fluid Filtration ±2 % FS @ 46cSt. 2 ms ±0.05 % FS/°C ± 0.5 % FS 3...420 bar 315 bar / (4569 psi) 420 bar / (6092 psi) Refer to diagram Steel NBR Steel, NBR +10...+60 °C / (50...140°F) -20...80 °C / (-4...176°F) +80 °C / (176°F) 25 µm Pin assignment M12x1; 4-pole PIN Assignment 1 V+ 2 Q signal 3 0 V / GND 4 150 -150...+150 l/min -165...+165 l/min M42 (NG16) 1050 Viscosity range Protection degree Electrical connection Plug Supply voltage Current consumption Output Load Signal noise EM compatibility Disturbance emissions Resistance to interference 15...100 cSt. IP67 DIN EN 60529 M12x1; 4-pole +18...+30 VDC 40 mA 0...20 mA = -FS...+FS (10 mA = 0 l/min) 150 < 5 mV EN 61000-6-3 EN 61000-6-2 39 Catalogue 4083/UK SCQ flow meter Screw plug hole and pressure-drop curve SCQ-150 30 Nm torque 50x30 77 ca. 97 SW27 hex27 X1) M42x1.5 X2) x1) O-ring 36.17x2.62 x2) PTFE with O-ring 2.64x2.62 Volumetric flow rate sensors 40 Catalogue 4083/UK Volumetric flow rate sensors SCQ flow meter SCAQ-GI-R1/2 100 8.5 36 SCAQ-150 80 30 10 44 M8 44 20 tief 60 120 68 42 A B Y X 15 10 42.5 55 0.5 2.1 G3/4 ø34 G1/4 ø16 1.3 19 80 Order code SCQ-150 (-150 to +150 l/min) M12x1, 4-pole; connecting plug; IP67 0 to 20 mA; -150...+150 l/min Accessories SCQ-150 Connector block G3/4 BSPP inner (A-B) and M42 inner With screw plug: M42 outer and G3/4 BSPP outer (A-B) Spare parts Spacer ring for SCQ-060 Seal kit for SCQ-060 Seal kit for SCQ-150 SCQ-150-10-07 SCAQ-150 SC-910 SC-911 SC-912 Connection cable and single plug Connection cable, assembled (open cable end) SCK-400-xx-xx Cable length (m) 2 m 02 5 m 05 10 m 10 Connecting plug M12 cable jack; straight 45 M12 cable jack; 90° angled 55 Single connector M12 cable jack; straight M12 cable jack; 90° angled SCK-145 SCK-155 41 Catalogue 4083/UK Volumetric flow rate sensors SCFT measurement turbine Device features Measurement principle: Turbine Response speed 50 ms Measurement range from 1 to 800 l/min Low flow resistance Suitable for reverse operation Built-in pressure and temperature ports Flow Rotation Output Function The turbine wheel is driven by the oil flow. The generated frequencies are processed through the digital electronics and influences from the disturbing flow effects are compensated for. Because of the low flow resistance QR, the hydraulic circuit operates with very low losses. Reverse operation is also possible because of the special vane (winged) design - so the turbine can be operated in Magnetic recording both directions. The turbine is fitted with an EMA-3 screw coupling for Axial turbine measuring pressure. Oil temperature can measured di- rectly in the oil flow of the turbine by connecting the tem- perature sensor (SCT-150). This provides all important measurements at the installation location. Application The SCFT is the ideal solution if the volumetric flow rate needs to be recorded loss-free across a wide flow range (up to 800 l/min.). 42 Catalogue 4083/UK Volumetric flow rate sensors SCFT measurement turbine Technical data SCFT- Flow measuring range Qn (l/min) Accuracy (± %) FS/IR @ 21cSt. Operating pressure Pn bar / (psi) Ports (A - B) Pressure drop P (bar) @ (FS) Weight (g) FS = Full Scale IR = Indicated Reading 015 1...15 060 3...60 150 5...150 300 8...300 ± 1 % FS 350 (5076) G1/2 BSPP 1.5 700 ± 1 % IR 350 (5076) G3/4 BSPP 1.5 1600 ± 1 % IR 350 (5076) G3/4 BSPP 1.5 1600 ± 1 % IR 350 (5076) G1 BSPP 4 1700 600 15...600 800 20...800 ± 1 % IR ± 1 % IR 290 (4206) G1 1/4 BSPP 400 (5801) G1 7/8 UNF 4 5 2700 5000 Accuracy Response time Thermal drift Repeat accuracy Resistance to pressure Qmax (l/min) Overload pressure Pmax Material Housing Seal Parts in contact with substances Ambient conditions Ambient temperature Storage temperature Tmax Fluid Filtration Viscosity range Protection class 50 ms ±0.05 % FS/°C ± 0.5 % FS QN x 1.1 PN x 1.2 Aluminium FKM Aluminium, steel, FKM -10...+50 °C / (14...122°F) -20...+80 °C / (-4...176°F) -20...+80 °C / (-4...176°F) 25 µm (10 µm for SCFT-015) 15...100 cSt. IP66 EN60529 Ports Temperature measurement (SCT-150-14-07) Pressure connection Pressure (VSTI) Electrical connection Plug Power supply V+ Output signal Complete output current range Current consumption Protection degree M10x1 OR EMA3 G1/4 BSPP M12x1; 5-pole 18...30 V 4...20 mA 0...FS l/min 0...21 mA < 30 mA IP66 EN60529 Pin assignment M12x1; 5-pole *n.c. = do not connect PIN Assignment 1 V+ 2 n.c. 3 Q signal 4 n.c.* 5 0 V / GND 43 Catalogue 4083/UK Volumetric flow rate sensors N R C E SCFT measurement turbine FLOW A B P Q M S # SCFT-015 A 37 B 136 C 37 E 115 M 70 N 0 P 25 Q N/A R 0 S 115 SCFT-060 62 190 50 130 103 5 50 92 5 157 SCFT-150 62 190 50 130 103 5 50 92 5 157 SCFT-300 62 190 50 134 103 7 52 90 9 150 SCFT-600 62 212 75 149 127 9 62 106 11 168 SCFT-800 100 212 75 152 126 10 60 104 10 181 44 Catalogue 4083/UK SCFT measurement turbine Order code SCFT M12x1, 5-pole; connecting plug; IP66 4...20 mA (3-wire) 1...15 l/min 3...60 l/min 5...150 l/min 8...300 l/min 15...600 l/min 20...800 l/min SCFT-015-22-07 SCFT-060-22-07 SCFT-150-22-07 SCFT-300-22-07 SCFT-600-22-07 SCFT-800-22-07 Connection cable and single plug Connection cable, assembled (open cable end) SCK-400-xx-xx Cable length (m) 2 m 02 5 m 05 10 m 10 Connecting plug M12 cable jack; straight 45 M12 cable jack; 90° angled 55 Single connector M12 cable jack; straight M12 cable jack; 90° angled SCK-145 SCK-155 Volumetric flow rate sensors 45 Catalogue 4083/UK Volumetric flow rate sensors SCVF volume counter Device features Measurement principle: Volume/geared counter Eight measurement ranges from 0.01 - 2 to 1 - 300 l/min Accuracy ± 0.5 % FS Withstands pressures up to 400 bar (5802 psi) High viscosity range Low noise Exact flow rate measurement over a wide viscosity range Versatile usage for different substances Gear counter for highly accurate flow rate measurements in hydraulic systems Function The SCVF geared counter functions as a volume flow meter. A very precisely crafted pair of geared wheels is driven by the fluid flow. The SCVF works over a wide viscosity range. Different seals permit usage in many different applications. Applications Due to the wide viscosity range, any liquid can be measured that can be pumped and has a certain degree of lubricating capability. Brake fluid (EPDM seal) Skydrol Mineral oils Hydraulic oil and Grease The SCVF is the ideal solution when carrying out precise flow rate measurements over a wide viscosity range. 46 Catalogue 4083/UK Volumetric flow rate sensors SCVF volume counter Technical data SCVFFlow measuring range (l/ min) Pressure range PN bar / (psi) Overload pressure PO bar / (psi) Connection Sound level dB (A) Resolution (pulses / litre) 002 004 015 0.01...2.0 0.02...4.0 0.2...15 040 0.4...40 060 0.4...60 080 0.4...80 150 300 0.6...150 1.0...300 400 (5802) 480 (6962) G3/8 BSPP < 60 40,000 315 (4569) 400 (5802) G3/8 BSPP < 60 25,000 400 (5802) 480 (6962) G3/8 BSPP < 60 4082 400 (5802) 480 (6962) G1/2 BSPP < 70 965 400 (5802) 480 (6962) G1/2 BSPP < 70 965 400 (5802) 480 (6962) G1/2 BSPP < 70 965 315 (4569) 350 (5076) G1 BSPP < 70 333.33 315 (4569) 350 (5076) G1 BSPP < 72 191 Accuracy Deviation from characteristic curve Response time Repeat accuracy Substance *) Material Housing Seal Ambient conditions Ambient temperature Storage temperature Fluid temperature Viscosity range Protection degree ± 0.3 % FS 20 cSt. ± 0.5 % FS 20 cSt. < 10 ms 0.01 % FS Hydraulic oil (25 micron filter) Material 1.7139 Contains no non-ferrous metal or silicone Steel FKM EPDM on request 0...+55 °C / (32...131°F) -25...+85 °C / (-13...185°F) -30...120 °C / (-22...148°F) Refer to diagram p. 48 IP65 DIN EN 60529 FS = Full scale value *)When using other substances, please state the viscosity range and the type of seals. (Attach the data sheet of the substance if possible) Electrical connection Plug Power supply V+ Current consumption Output signal Load EM compatibility Disturbance emissions Resistance to interference M12x1; 4-pole +18...+30 VDC < 28 mA 0...20 mA 0...FS l/min 150 EN 61000-6-3 EN 61000-6-2 Pin assignment M12x1; 4-pole PIN Assignment 1 V+ 2 Q-signal 3 0 V / GND 4 47 Catalogue 4083/UK SCVF volume counter Technical data SCVF-002 p - Viscosity SCVF-004 p -Viscosity p [bar] p [bar] Volumetric flow rate sensors p [bar] Q [l/min] SCVF-015 p -Viscosity Q [l/min] SCVF-040/060/080 p -Viscosity p [bar] Q [l/min] SCVF-150 p -Viscosity Q [l/min] SCVF-300 p -Viscosity p [bar] p [bar] p = pressure loss Q [l/min] 48 Q [l/min] Catalogue 4083/UK M12x1 SCVF volume counter J D 42 G F P 57 X2 C X1 øN M P M L Volumetric flow rate sensors L 58 K øN A K Type SCVF-002 SCVF-004 SCVF-015 SCVF-040 SCVF-060 SCVF-080 SCVF-150 SCVF-300 Weight [kg] 1.8 2 2 5.2 9 13 All measurements in mm Torque [Nm] 14 14 14 35 120 120 A CDF GJ KL M øN P 85 10 60 50 87 - 70 40 20 6.5 M6 85 9 60 56 - 70 40 20 6.5 M6 85 13 60 57 94 - 70 40 20 9 M6 120 13 95 72 109 10.5 84 72 35 16 M8 170 18 120 89 140 46.5 46 95 50 25 M12 170 22 120 105 142 40 46 95 50 25 M12 49 Catalogue 4083/UK Volumetric flow rate sensors B F L M øN c f J R C SCVF volume counter Dimensioned drawings connection plate A E K øH P øG øe ød X Type kg A B C SCVF-002 SCVF-004 1.8 85 90 35 SCVF-015 SCVF-040 SCVF-060 2.9 100 120 37 SCVF-080 SCVF-150 SCVF-300 14 160 165 80 All measurements in mm E F øG øH J 65 76 7 11 7 80 106 7 11 7 140 145 9 15 9 K L M øN P R c ød 70 40 20 6.5 M6/t = 14 17 0.7 25 84 72 35 12 M8/t = 18 17.5 0.7 29 46 95 50 25 M12/t = 24 28 1 42 øe BSPP f G3/8 13 G 1/2 15 G1 19 50 Catalogue 4083/UK SCVF volume counter Order code SCVF M12x1, 4-pole; connecting plug; IP65; incl. connection plate 0...20 mA 0.01...2 l/min SCVF-002-10-07 0.02...4 l/min SCVF-004-10-07 0.2...15 l/min SCVF-015-10-07 0.4...40 l/min SCVF-040-10-07 0.4...60 l/min SCVF-060-10-07 0.4...80 l/min SCVF-080-10-07 0.6...150 l/min SCVF-150-10-07 1...300 l/min SCVF-300-10-07 Connection cable and single plug Connection cable, assembled (open cable end) SCK-400-xx-xx Cable length (m) 2 m 02 5 m 05 10 m 10 Connecting plug M12 cable jack; straight 45 M12 cable jack; 90° angled 55 Single connector M12 cable jack; straight M12 cable jack; 90° angled SCK-145 SCK-155 Volumetric flow rate sensors 51 Catalogue 4083/UK The Controller Family Device features Large display Freely adjustable Rugged metal construction Compact size Long-term stability Dependable Immune to interference This controller is used in control, regulation or monitoring systems where switching signals or analogue signals are used or a display is required. The controller can replace the following: Mechanical switches Mechanical displays (pressure gauges, thermometers, inspection glass) Sensors All the above mentioned functions can be combined in one device. All control devices have a compact and pivoting metal housing so that they can be mounted optimally under adverse installation conditions. The large display can always be perfectly positioned so that it is easy to read even at longer distances. Both of the switching outputs can be set individually either as NO or NC. They also both have hysteresis and the window functions. Therefore the on and off switching values as well as delay times (attenuation) for each of the switching points can be chosen freely. Thanks to these easy switching functions, intelligent adjustments can be set which are normally not possible using a mechanical switch. Therefore, many switches can be replaced with one controller. The controllers offer good practical characteristics combined with diverse mounting and setting options. Because of its compact design, long lifespan and high functionality, this controller is ideal for the permanent series use in hydraulic and pneumatic applications. The Controller Family 52 Catalogue 4083/UK The Controller Family Overview SCPSDi SCPSD SCTSD SCTSD-L Range of use Applications Pressure display and monitoring Compact size Resistant to pres- sure peaks Resistant to shock and vibration IO link Compact size Resistant to pres- sure peaks Resistant to shock and vibration Test benches Processing equipment Conveying and lifting equipment General machine construction Pneumatic plant construction Hydraulic plant construction Temperature display and monitoring Temperature display Modular design Suitable for control panel and tank construction High pressure version Temperature display and level monitoring Temperature display Fixed level contacts Order code SCPSDi-xxx-x4-x7 Refer to page 54-59 SCPSD-xxx-x4-xx 60-65 SCTSD-150-xx-xx 66-77 SCTSD-L-xxxxx-xxxxxQ2 78-81 SCLSD SCLTSD SCOTC Range of use Level indication and monitoring Level/temperature display and monitoring Level display Practical monitoring with window function Continuous level measure- ment Level display Temperature display Continuous level measure- ment One bore hole Applications Test benches Processing equipment Conveying and lifting equipment General machine construction Pneumatic plant construction Hydraulic plant construction Level display Temperature display Continuous level measurement One bore hole Connection to the filling coupling Connection to the air filter Order code SCLSD-xxx-x0-07 Refer to page 82-87 SCLTSD-xxx-x0-07 88-93 SCOTC-xxx-x0-07 94-99 53 Catalogue 4083/UK The Controller Family SCPSDi PressureController Device features IO LINK Compact size VDMA menu Rugged ECO mode MPa, bar, PSI > 360° pivot function Metal housing 180° reversible display Installation width 35 mm Analogue output V/mA Installation height 78 mm Operator safety improved with LOCK 1 2 3 4 I/O The SCPSDi is an electronic pressure switch with: Pressure display Two programmable switching outputs Optional analogue output signal IO-Link interface VDMA menu navigation The key features of the SCPSDi are the innovative design and the resulting installation options combined with the diverse connection possibilities. These unique functions make the SCPSDi ideal for permanent series use in industrial applications. Innovative construction design The external-thread pressure port is stop-free and can be turned independently of the housing. So you can install the pressure connection without turning the housing. The small size means that it can easily be installed in cramped quarters. After the installation, the housing can be fully rotated over 360° with no stop. It also locks into position while under pressure. For the internal-thread pressure port, all components that come into contact with the pressurized substance are made from stainless steel. It does not have any seals so it can be used with a wide range of substances including corrosive and aggressive media. The display is readable from large distances and can be rotated through 180° for overhead installation. A horizontally-mounted display is optionally available. Reliable / safe / sturdy The pressure is recorded with a long-term stable and maintenance-free measuring cell. A functional error is signalled and can be processed further according to DESINA. The metal housing is void of moving seals and is resistant to moisture, shock and vibrations. Easy to use The terminology and symbols used, as well as the menu structure used for setting parameters can be easily browsed using the buttons in accordance with the VDMA standard journal (VDMA 24574-1) or automatically using IO Link. Universal Each switching output can be adjusted individually: NO/NC contact On/off switching pressures Delay times Hysteresis / window function The optional analogue output is switchable between 0/4 to 20 mA and 0 to 10 V. An unintentional parameter change is prevented with use of the LOCK function (button lock). Numerous versions are available for the many different applications. Diverse pressures ranges up to 600 bar Diverse inner and outer threads With or without analogue outputt The Controller Family 54 Catalogue 4083/UK SCPSDi PressureController Device features Display Active-lit LED display Pressure display Units are displayed Bar / PSI / MPa Switch status is shown 180° rotation for top mount ECO mode* Design No moveable seals Few housing elements No mixing of materials Ergonomic Minimal surface area for dirt Compact size Plug in the front Compact installation dimensions Sloped display Measuring component Hermetically sealed and welded stainless steel membrane Zero-point stability Long-term stability No wear and tear Excellent pressure resistance Up to a nominal pressure of 600 bar Innovative construction of external threads The external-thread pressure port is stop-free and can be turned independently of the housing. So you can install the pressure connection without turning the housing. The housing can be set in any direction for optimal cable routing and locks under pressure. Self-contained housing No force is exerted on the measuring component during installation Stainless steel BSPP/UNF/NPT NBR sealing Housing Metal housing No movable elements, therefore wear-free Not sensitive to external environment Waterproof IP67 Rugged Adjustments and settings VDMA menu navigation Two large buttons LOCK function** M12 Threaded metal connection The plug cannot be over-rotated or broken off VDMA-compliant assignment of pins IO link DESINA 2 switching outputs Switchable analogue output 0...20 mA 4...20 mA 0...10 V Excellent interference immunity Inner thread All components that come into contact with the substance being measured are made from stainless steel No internal sealing components Wide range of compatible substances Resistant against corrosive and aggressive substances * ECO mode (activated via menu): pressure switch is run with minimum power in this mode ** LOCK function (button lock): Prevents accidental changing of the pressure switch parameters The Controller Family 55 Catalogue 4083/UK SCPSDi PressureController Technical data SCPSDi- 010 016 025 060 100 250 400 600 Pressure range Pn, relative bar / (psi) Adjusting range RSP...SP (Lowest reset switch point ... highest switch point) -1...10 -1...16 -1...25 0...60 0...100 0...250 0...400 0...600 (-14.5...145) (-14.5...232) (-14.5...363) (0...870) (0...1450) (0...3625) (0...5802) (0...8702) Overload pressure * Pmax Burst pressure ** Pburst Display resolution Increment size bar / (psi) 0.01 (0.15) 0.01 (0.15) 0.01 (0.15) 2 x Pn 3 x Pn 0.1 0.1 (1.45) (1.45) 1 (14.5) 1 (14.5) 1 (14.5) Smallest adjustable difference between 0.01 SP and RSP (SP-RSP) bar / (psi) (0.15) 0.01 (0.15) 0.01 (0.15) 0.1 (1.45) 0.1 (1.45) 1 (14.5) 1 (14.5) 1 (14.5) * DIN EN 60770-1 ** DIN 16086 Input values Switching cycles 100 million Scanning rate 10 ms Process connection Inner/outer thread G1/4 BSPP, 7/16 UNF, NPT Tightening torque 35 Nm Parts in contact with substances Inner thread Stainless steel 1.4301; 1.4404 Outer thread Stainless steel 1.4301; 1.4404; 1.0718 CF; NBR Temperature range of substance -20...+105 °C MTTFd > 100 years Output values Accuracy* ± 0.5% FS typ.; +/- 1% FS max. Temperature drift ± 0.03% FS/K Long-term stability ± 0.2% FS/a Repeat accuracy ± 0.25% FS Switch point accuracy ± 0.5% FS typ.; +/- 1% FS max. Display accuracy ± 0.5% FS +/- 1 digit typ. ± 1% FS +/- 1 digit max. Max. display value 110% Pn Analogue output +/- 0.5% FS typ.; +/- 1% FS max. * Including non-linearity, hysteresis, zero-point and full-scale deviations (corresponds to measurement deviations according to IEC 61298-2) Response speed Switching output Analogue output 10 ms 10 ms Electrical connection Supply voltage V+ Electrical connection Short circuit protection Reverse polarity protection Overload protection Current consumption Switch-on current Outputs Switching output 1 Switching output 2 IO Link Analogue output *see ECN15003 Nominal 24 VDC; 12...30 VDC M12x1; 4-pole according to DIN EN 61076-2-101 Yes Yes Yes < 50 mA; in ECO mode < 40 mA < 100 mA High-side/low-side switch (PNP/ NPN) Switching current: max. 200 mA Short-circuit current: 400 mA (short-term), Short-circuit resistance Switching voltage: Supply voltage 1.5 VDC High-side (PNP)* Optional Switching current: max. 500 mA Short-circuit current: 800 mA (momentary), short-circuit-proof Switching voltage: V+ 1.5 VDC Specification V1.0 PNO Order No. 2.802 4...20 mA, 0...20 mA, 0...10 V The Controller Family 56 Catalogue 4083/UK SCPSDi PressureController Technical data Housing Rotating Readability of the display Display Material Protection degree Weight Ambient conditions Ambient temperature range Storage temperature range Vibration resistance Shock resistance EM compatibility Disturbance emissions Interference immunity General MTTFd RoHS-compliant > 360° viewing angle can be rotated 180° Configurable (programming) 4-digit 7-segment LED with additional symbols for units and switching status display; Digit height: ~6 mm, Height of units: ~2 mm Die-cast nickel-plated zinc IP67 148 g -25...+85 °C (-13...185°F) -40...+85 °C (-40...185°F) 20 g; 10...500 Hz; IEC600682-6 50 g; 11 ms; IEC60068-2-29 EN 61000-6-3 EN 61000-6-2 > 100 years Yes Pin assignment M12x1; 4-pole PIN Assignment 1 V+ 2 S2 out / analogue 3 0 V / GND 4 S1 out / IO Link The Controller Family 57 Catalogue 4083/UK SCPSDi PressureController SCPSDi-xxx-xx-17 SCPSDi-xxx-xx-27 S1) SW22 SCSD-S22 The Controller Family 58 Catalogue 4083/UK SCPSDi PressureController SCPSDi-xxx-x4-17 G1/4ED L1) 77.5 L2) 35 X1) ED seal Order code SCPSDi 2 switching outputs; SCPSDi-xxx-04-x7- SCPSDi 2 switching outputs Marine; SCPSDi-xxx-04-x7-MA (approved by DNV/GL/ABS) without analogue output, G 1/4, M12x1; 4-pole 1 switching output; 1 switching output Marine; (approved by DNV/GL/ABS) switchable analogue output, G 1/4, M12x1; 4-pole SCPSDi-xxx-14-x7 SCPSDi-xxx-14-x7-MA SCPSDi-xxx-x4-27 G1/4 Pressure range 010 016 025 060 100 250 400 600 Version Outer thread Inner thread 010 016 025 060 100 250 400 600 1 2 Connection cable and single plug Connection cable, assembled (open cable end) SCK-400-xx-xx Cable length (m) 2 m 02 5 m 05 10 m 10 Connecting plug M12 cable jack; straight 45 M12 cable jack; 90° angled 55 Single connector M12 cable jack; straight M12 cable jack; 90° angled SCK-145 SCK-155 Accessories: Securing clamp SCSD-S27 The Controller Family 59 Catalogue 4083/UK SCPSD PressureController Device features Compact size High protection class Rugged Many variants Dependable Pivoting Easily operable Analogue output Long-term stability Password Excellent interference im- MPa, bar, PSI munity Metal housing 1 2 3 4 The PressureController combines the functions of a pressure switch, a pressure sensor and a display device. Pressure gauge (manometer) Switching outputs Analogue signal The PressureController is easy to operate, has a compact design and is very reliable. The PressureController features excellent technical specifications, optimal pressure management and a wide variety of installation options. This makes it perfect for permanent series use in industrial applications. Easy to use The parameters are set using the keys or over a programming module. High functionality Each switching output can be adjusted individually: NO/NC contact On/off switching pressures Delay times Hysteresis / window function Attenuation Thanks to these easy switching functions, intelligent adjustments can be set which are normally not possible using a mechanical switch. Therefore, many switches can be replaced with one controller. The analogue output is individually adjustable 0/4...20 mA switchable Starting pressure selectable End pressure selectable Reliable and safe The pressure is recorded with a long term stable measuring cell. A functional error is signalled and can be processed further according to DESINA. Parameters can be password protected to avoid unauthorised changes. Rugged The housing is made of metal and is resistant to moisture, shock and vibrations. The electronics are protected against reverse polarity, over-voltage and short-circuits. Everything at a glance The large illuminated display can be read from long distances. The pressures can be displayed in MPa, bar or PSI. Optimal installation possibilities The SCPSD is ideal for installation under critical conditions because of its compact design and excellent interference immunity. The display is always easy to read because the housing can be positioned as needed. Universal Diverse versions are available for the many different applications. The Controller Family 60 Catalogue 4083/UK SCPSD PressureController Device features Everything at a glance Sloped display Digital display Large Illuminated Display PSI/bar/Mpa Current pressure Minimum pressure Maximum pressure Switching points Variable installation Compact size 290° pivotable Pressure port Stainless steel Long term stable measuring cell Wide range of compatible sub- stances SensoControl I II bar/PSI UNIT Thread Inner thread Optical interface Switch status is shown Easy to use 3 large buttons Display of the unit Rugged Metal housing Waterproof Excellent interference immunity Vibration proof Shock proof Tube clamp Safe installation with the sturdy SCSD-S27 clamp Outer thread Programming module Adjustable through ControllerWIN Software The Controller Family 61 Catalogue 4083/UK SCPSD PressureController Technical data SCPSDPressure range Pn relative bar / (psi) Adjusting range RSP...SP Overload pressure Pn bar / (psi) Burst pressure Pn bar / (psi) Display resolution bar / (psi) Smallest adjustable difference between SP and RSP (SP-RSP) bar / (psi) Measuring component Parts in contact with substances 004 010 016 060 100 250 -1...4 -1...10 -1...16 0...60 0...100 0...250 (-14.5...58) (-14.5...145) (-14.5...232) (0...870) (0...1450) (0...3626) 10 (145) 12 (174) 0.01 (0.15) 20 (290) 25 (363) 0.01 (0.15) 40 (580) 50 (725) 0.01 (0.15) 120 (1740) 550 (7977) 0.1 (1.45) 200 (2400) 800 (11,603) 0.1 (1.45) 500 (7521) 1200 (17,405) 1 (14.5) 0.03 0.06 0.09 0.3 0.6 2 (0.44) (0.87) (1.31) (4.35) (8.7) (29) Ceramic Stainless steel 1.4404; Ceramic AL2O3; NBR Thin film DMS Stainless steel 1.4404; 1.4542 400 0...400 (0...5802) 800 (11,603) 1700 (24,656) 1 (14.5) 3 (43.5) 600 0...600 (0...8702) 1200 (17,405) 2200 (31,908) 1 (14.5) 3 (43.5) Input parameters Switching cycles 100 million Polling rate 5 ms Connector thread G1/4 BSPP; ED soft seal NBR* (DIN 3852 T2, Form X); ED (DIN3852 T11, Form E) Tightening torque 35 Nm Temperature range of substance -20...+85 °C (-4...185°F) Weight Approx. 300 g MTTFd > 100 years Output values Accuracy ± 0.5 % FS typ.; ± 1 % FS max. Temperature drift ± 0.02 % FS/°K type (at -20...+85 °C) ± 0.03 % FS/°K max. Long-term stability ± 0.2 % FS/a Repeat accuracy ± 0.25 % FS Switching point accuracy ± 0.5 % FS typ.; ± 1 % FS max. Display accuracy ± 0.5 % FS type ± 1 Digit ± 1 % FS max. ± 1 Digit Response speed Switching output 10 ms Analogue output 10 ms Electrical connection Supply voltage V+ 15 to 30 VDC nominal 24 VDC; Protection class 3 Electrical connection M12x1; 4-pole; 5-pole; with gold-plated contacts device connector Short-circuit protection Yes Protection against wrong Yes insertion Overload protection Yes Current consumption < 100 mA Housing Adjustable direction to 290°C (554°F) Material Painted zinc die cast Z 410 Foil material Polyester Display 4-digit 7-segment LED; red; digit height 9 mm Protection degree IP67 DIN EN 60529; The Controller Family 62 Catalogue 4083/UK SCPSD PressureController Technical data Pin assignment Ambient conditions Ambient temperature range -20...+85 °C (-4...185°F) Storage temperature range -40...+100 °C (-40...212°F) Vibration resistance 20 g; 10...500 Hz IEC60068-2-6** Shock resistance 50 g; 11 ms IEC60068-2-29** EM compatibility Disturbance emissions EN 61000-6-3 Resistance to interference EN 61000-6-2 Outputs Switching outputs Two MOSFET high-side switches (PNP) Contact functions NO / NC contact; window / hysteresis; function freely adjustable Switching voltage Switching current max. V+ -1.5 VDC 0.5 A per switch Short-circuit current 2.4 A per switch Analogue output 0/4...20 mA; programmable; freely scalable; RL (Supply voltage - 8 V)/ 20 mA ( 500 ) * different sealing material (FKM, EPDM etc.) upon request ** does not apply for version DIN EN 175301-803 Form A (old DIN43650) Information about selecting the pressure range The following parameters are relevant when working with pressure switches: System pressure Switching point pressure Since a 400-bar (5802 psi) pressure switch has a comparable resolution (of 1 bar, 14.5 psi) as that of a 600-bar (8702 psi) pressure switch (also 1 bar), it is possible to use a 600-bar (8702 psi) pressure switch even when there is a smaller nominal pressure (for example, 315 bar, 4569 psi). SCPSD-xxx-14-x7 1 switching and 1 analogue output M12x1; 4-pole PIN Assignment 1 V+ 2 Analogue out 3 0 V / GND 4 S1 out SCPSD-xxx-04-x7 2 switching outputs; M12x1; 4-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out SCPSD-xxx-14-x5 2 switching outputs; 1 analogue output; M12x1; 5-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out 5 Analogue out This is a positive feature because it provides the same precision with improved safety and fewer product variants. The Controller Family 63 Catalogue 4083/UK 10 12 (20.1) 93.5 9.1 (20.1) 93.5 14.1 (25.1) 98.5 SCPSD PressureController Outer thread SCPSD-xxx-x4-1x 39.5 SensoControl I II bar/PSI UNIT Inner thread SCPSD-xxx-x4-2x Up to 10 bar (145 psi) 39.5 SensoControl I II bar/PSI UNIT G1/4A ø18.8 G1/4 ø26.8 M12 connecting plug SCPSD-xxx-x4-x5 46.3 Clamp (accessory) SCSD-S27 57 From 16 bar (232 psi) 39.5 SensoControl I II bar/PSI UNIT G1/4 ø26.8 40.5 3 30 19 SW27 ø32 7 SCSD-S27 73 87 The Controller Family 73.4 64 Catalogue 4083/UK SCPSD PressureController Order code Connection cable and single plug SCPSD digital pressure switch 2 switching outputs; no analogue output: SCPSD-xxx-04-x7 M12x1 connecting plug; 4-pole 1 switching output; with analogue output: SCPSD-xxx-14-x7 M12x1 connecting plug; 4-pole 2 switching outputs; with analogue output SCPSD-xxx-14-x5 M12x1 connecting plug; 5-pole Pressure range 004 004 010 010 016 016 060 060 100 100 250 250 400 400 600 600 Connection cable, assembled (open cable end) Cable length (m) 2 m 5 m 10 m Connecting plug M12 cable jack; straight M12 cable jack; 90° angled Single connector M12 cable jack; straight M12 cable jack; 90° angled SCK-400-xx-xx 02 05 10 45 55 SCK-145 SCK-155 Version G1/4 BSPP outer thread 1 G1/4 BSPP inner thread 2 Accessories: PC Programming KITSCSD-PRG-KIT Securing clamp SCSD-S27 Reducing adapter M22x1.5SCA-1/4-M22x1.5-ED Reducing adapter G1/2 BSPPSCA-1/4-ED-1/2-ED Attenuation adapter SCA-1/4EDX1/4-D Attenuation adapter SCA-1/2EDX1/2-D Flange adapter SCAF-1/4-40 for mechanical pressure switch Order example SCPSD-100-04-27 Pressure range 100 bar 2 switching outputs G1/4 BSPP inner thread M12 connecting plug SCPSD-004-14-17 Pressure range 4 bar 1 switching output 1 analogue output G1/4 BSPP outer thread M12 connecting plug The Controller Family 65 Catalogue 4083/UK SCTSD TemperatureController Device features Compact size Rugged Dependable Easily operable Metal housing High protection class Modular construction Many variants Analogue output Pivoting Password °C, °F 1 2 3 4 The TemperatureController combines the functions of a temperature switch, a temperature sensor and a display device. Temperature display (Thermometer) Switching outputs Analogue signal Simple operation, extensive functionality and a modular design are the most important characteristics of the TemperatureController. The TemperatureController offers excellent technical specifications, optimum temperature management, combined with a variety of installation options. It is perfect for applications when the temperature needs to be reliably monitored and easily viewed. The analogue output is individually adjustable 0/4...20 mA switchable Adjustable start temperature Adjustable end temperature Reliable and safe A functional error is signalled and can be processed further according to DESINA. Parameters can be password protected to avoid unauthorised changes. Rugged The housing is made of metal and is resistant to moisture, shock and vibrations. The electronics are protected against reverse polarity, over-voltage and short-circuits. Easy to use The normal temperature monitoring limit values adjustments (e.g. cooling and alarm) are made either with the keys or the programming module. High functionality Each switching output can be adjusted individually: NO/NC contact On/off switching pressures Delay times Hysteresis / window function time delay Thanks to these easy switching functions, intelligent adjustments can be set which are normally not possible using a mechanical switch. Therefore, many switches can be replaced with one controller. Everything at a glance The large illuminated display can be read from long distances. The temperature can be selected to °C or °F. The temperature is always optimally readable due to the modular construction and the pivoting housing. Optimal installation possibilities Sensors in various lengths are available for different tank sizes. These can be directly connected to the TemperatureController via a cable. Additionally the temperature sensor is available up to 630 bar for high pressure applications. Universal Diverse versions are available for the many different applications. 66 Catalogue 4083/UK The Controller Family Temperature in °C The Controller Family SCTSD TemperatureController Application example Tank temperature monitoring Machine On / Off The facility should shut down when the tank temperature falls below 10°C (50°F) or climbs above 60°C (140°F). A protective wire-break mechanism should be considered to improve safety. Cooling If the temperature climbs above 50°C (122°F), the tank temperature should be cooled with a refrigerating unit down to 40°C (104°F). SP1 = 60 °C (140°F) SP2 = 50 °C (122°F) rSP2 = 40 °C (104°F) rSP1 = 10 °C (50°F) Machine On/Off Machine Switching output 1 SP1 = 60 °C/ (140°F) On rSP2 = 10 °C / (50°F) Window function, NO contact Off Cooling Cooling Switching output 2 SP2 = 50 °C/ (122°F) On rSP2 = 40 °C / (104°F) Hysteresis / NO contacts Off Tank temperature The output S1 is closed if the temperature is between 60°C and 10°C. If the temperature exceeds 50 °C, the contact S2 closes and only resets at 40 °C. Time 67 Catalogue 4083/UK SCTSD Modular TemperatureController Device features Everything at a glance Sloped display Digital display Large Illuminated Display °C, °F Current temperature Minimum temperature Maximum temperature Switching points Variable installation Compact size 290° pivotable Connect as required 2 switching outputs Analogue output 0...20 or 4...20 mA Freely programmable Scalable Plug M12 DIN EN 175301-803 Form A (old DIN43650) Optical interface Switch status is shown Easy to use 3 large buttons Display of the unit Rugged Metal housing Waterproof Excellent interference immunity Vibration proof Shock proof Tube clamp Safe installation with the sturdy SCSD-S27 clamp Programming module Adjustable through ControllerWIN Software The Controller Family 68 Catalogue 4083/UK SCTSD Modular TemperatureController Device features Adjustable height Through clamping thread SCA-TT-10-1/2 Cable SCK-410-03-45-45 High pressure temperature sensor 630 bar SCTT-20-010-07 Temperature sensor Stainless steel Wide range of compatible substances Diverse lengths SCTT-10-xxx-07 Connection adapter SCA-TT-10-SD Immersion tube Additional with High pressures Aggressive substance Immersion tube SCA-TT-10-xxx The Controller Family 69 Catalogue 4083/UK SCTSD Modular TemperatureController Technical data Input parameters SCT-150 Display range -50...+150 °C / (-58...302°F) Sensor input PT1000 Sensor connection M12x1; 4-pole Output values Switching accuracy at 25 °C ± 0.35 % FS Display accuracy at 25 °C ± 0.35 % FS ± 1 Digit Electrical connection Supply voltage V+ 15...30 VDC nominal 24 VDC; Protection class 3 Electrical connection M12x1; 4-pole; 5-pole; Device plug DIN EN 175301-803 Form A (old DIN43650) Short-circuit protection Yes Overload protection Yes Current consumption < 100 mA EM compatibility Disturbance emissions EN 61000-6-3 Resistance to interference EN 61000-6-2 * does not apply for version DIN EN 175301-803 Form A (old DIN43650) Temperature sensor SCTT-10-xxx-07 Measuring component PT1000/DIN EN 60751, Class B Measuring range Response time -40...+125 °C 0.5 = 6 s/ 0.9 = 25 s Accuracy ± 0.3 K + 0.005* t Material Stainless Steel 1.4571 Nominal pressure (max) 10 bar Temperature of substance -40...+125 °C / (-40...257°F) Ambient temperature -25...+80 °C / (-13...176°F) (for the connector area) Storage temperature -25...+85 °C / (-13...185°F) Housing Material Foil material Display Protection degree Ambient conditions Ambient temperature range Storage temperature range Vibration resistance Shock resistance Outputs Switching outputs Contact functions Response speed Accuracy Analogue output Orientation adjustable to 290° Die-cast zinc Z 410; painted Polyester 4-digit 7-segment LED; red; digit height 9 mm IP67 EN 60529 IP65 with device plug DIN EN 175301-803 Form A (old DIN43650) -20...+85 °C / (-4...185°F) -40...+100 °C / (-40...212°F) 20 g; 10...500 Hz IEC60068-2-6* 50 g; 11 ms IEC60068-2-29* 2 x PNP high-side switch, 0.7 A/switch NO / NC contact; window / hysteresis 300 ms ± 1 % FS 0/4...20 mA; programmable; freely scalable; 4...20 mA = -40...125 °C / (-40...257°F) High pressure sensor SCTT-20-010-07 Measuring component PT1000/DIN EN 60751, Class B Measuring range Response time -40...+125 °C / (-40/257°F) 0.5 = 3 s/ 0.9 = 15 s Accuracy ± 0.3 K + 0.005*t Material Stainless Steel 1.4404 Threaded stud M10x1 Seal O ring 7.65x1.78 mm; FKM Measuring pipe diameter 7 mm Installation length 18.5 mm Nominal pressure Pn Overload pressure Pmax Burst pressure Pburst Temperature of substance 630 bar 800 bar 1200 bar -40...+125 °C /(-40...257°F) Ambient temperature -25...+80 °C / (-13...176°F) (for the connector area) Storage temperature -25...+85 °C / (-13...185°F) The Controller Family 70 Catalogue 4083/UK SCTSD Modular TemperatureController Pin assignment SCTSD-150-00-06 1 switching output DIN EN 175301-803 Form A 4-pole (old 43650) PIN Assignment 1 V+ 2 0 V / GND 3 S1 out - SCTSD-150-00-07 2 switching outputs M12x1; 4-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out SCTSD-150-10-07 1 switching output, 1 analogue output M12x1; 4-pole PIN Assignment 1 V+ 2 Analogue out 3 0 V / GND 4 S1 out SCTT-x0-xxx-07 SCTSD-150-10-05 2 switching outputs, 1 analogue output M12x1; 5-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out 5 Analogue out The Controller Family Measuring range Display resolution Increment size -50...150 °C / (-58...302°F) 0.1 °C / (32.2°F) Lowest reset switch point RSP -50 °C / (-58°F) Largest switching value SP 150 °C / (302°F) Smallest adjustable difference between SP and RSP (SP-RSP) 0.8 / (33.4°F) 71 Catalogue 4083/UK 73.4 12.1 14 (20.1) 93.5 SCTSD Modular TemperatureController M12 connecting plug SCTSD-150-x4-05 46.3 39.5 SensoControl I II UNIT °C/°F SW27 ø32 M12x1 M24x1.5 Temperature sensor SCTT-10-xxx-07 ø20 M12x1 DIN 43650 SCTSD-xxx-00-06 47.7 High pressure temperature sensor SCTT-20-010-07 Ø15 M12x1 42.5 SW17 HEX17 8 17.5 O-Ring 7.65x1.78 Ø7 M10x1 Connection adapter (accessory) SCA-TT-10-SD M24x1.5 Clamping thread (accessory) SCA-TT-10-1/2 30 41 14 28 SW27 EolasticDichtung G1/2A ø26.8 Material: Stainless Steel 1.4404 Male stud: G1/2A BSPP DIN3852-E Seal type: ED (Eolastic seal type) Screw plug hole G1/2A BSPP DIN3852-E Replacement seals: ED1/2VITX (FKM) 14 SW19 SW27 EolasticDichtung G1/2A ø26.8 GE10LR1/2EDOMD71: (with 10 mm bore hole) Stainless Steel 1.4571 EO-2-functional nut: FM10L71 Male stud: G1/2A BSPP DIN3852-E Seal type: ED (Eolastic seal type) Replacement seal: ED1/2VITX (FKM) L ø10 The Controller Family 72 Catalogue 4083/UK SCTSD Modular TemperatureController Ø14.5 Sensor cable 3 m (accessory) SCK-410-03-45-45 46 41.5 Ø14.5 Order code SCTSD module 1 switch output; no analogue output DIN EN 175301-803 Form A (old DIN 43650) connecting plug SCTSD-150-00-06 Clamp (accessory) SCSD-S27 57 2 switch outputs; no analogue output SCTSD-150-00-07 M12x1 connecting plug; 4-pole 1 switch output; with analogue output SCTSD-150-10-07 M12x1 connecting plug; 4-pole 2 switch outputs; with analogue output SCTSD-150-10-07 M12x1 connecting plug; 5-pole 40.5 7 SCSD-S27 19 3 30 Accessories: Securing clamp SCSD-S27 Sensor cable 3 m (SCTSD-SCTT)SCK-410-03-45-45 Clamping thread G1/2 BSPP SCA-TT-10-1/2 Connection adapter (SCTSD-SCTT) SCA-TT-10-SD High pressure temperature sensorSCTT-20-10-07 Immersion tube G1/2 BSPPSCA-TT-10-xxx 73 Length mm 87 100 mm 100 150 mm 150 250 mm 250 Order example Temperature sensor SCTT-10-xxx-07 Components for the control panel - high pressure version Securing clamp SCSD-S27 Sensor cable 3 m (SCTSD-SCTT)SCK-410-03-45-45 High pressure temperature sensorSCTT-20-10-07 Components for the control panel Securing clamp SCSD-S27 Sensor cable 3 m (SCTSD-SCTT)SCK-410-03-45-45 Clamping thread G1/2 BSPP SCA-TT-10-1/2 Temperature sensor 150 mm SCTT-10-150-07 Optional: Immersion tube G1/2 BSPP 100 mm SCA-TT-10-100 Length mm 100 mm 100 150 mm 150 250 mm 250 Connection cable and single plug Connection cable, assembled (open cable end) SCK-400-xx-xx Cable length (m) 2 m 02 5 m 05 10 m 10 Direct mounting components Connection adapter (SCTSD-SCTT) SCA-TT-10-SD Temperature sensor 100 mm SCTT-10-100-07 Optional: Immersion tube G1/2 BSPP 200 mm SCA-TT-10-200 Connecting plug M12 cable jack; straight M12 cable jack; 90° angled Single connector M12 cable jack; straight M12 cable jack; 90° angled 45 55 SCK-145 SCK-155 The Controller Family 73 Catalogue 4083/UK SCTSD high pressure TemperatureController Device features Everything at a glance Sloped display Digital display Large Illuminated Display °C, °F Current temperature Minimum temperature Maximum temperature Switching points Rugged Metal housing Waterproof Excellent interference immunity Vibration proof Shock proof SensoControl I II UNIT °C/°F Optical interface Switch status is shown Easy to use 3 large buttons Display of the unit Connect as required 2 switching outputs Analogue output 0...20 or 4...20 mA Freely programmable Scalable M12 connecting plug Variable installation Compact size 290° pivotable High pressure resistance Up to 630 bar (1166 psi) Programming module Adjustable through ControllerWIN Software The Controller Family 74 Catalogue 4083/UK SCTSD high pressure TemperatureController Technical data Input values SCTSD-150-x2-0x Measuring range -40...+100 °C / (-40...212°F) Input for measuring ele- PT1000/DIN EN 60751; ment Class B Range of use Liquid media, air Output values Switching accuracy at 25 °C ± 0.35 % FS Display accuracy at 25 °C ± 0.35 % FS ± 1 Digit Temperature margin of error ± 0.01 % FS/°C typ. (for -20...+85 °C / -4...185°F) Long-term stability ± 0.2 % FS/a Electrical connection Supply voltage V+ 15 to 30 VDC (with protection against polarity reversal) Electrical connection M12x1; 4-pole; 5-pole; with gold-plated contacts Short-circuit protection Yes Overload protection Yes Current consumption < 100 mA Mechanical connection Threaded male stud M10x1 Seal O-ring 7.65x1.78 mm; FKM Measuring pipe diameter 7 mm Installation length 18.5 mm Material Stainless Steel 1.4404 PN pressure Pmax Burst pressure 630 bar 800 bar 1200 bar Housing Adjustable direction to 290°C Material Die-cast zinc Z 410; painted Foil material Polyester Display 4-digit 7-segment LED; red; digit height 9 mm Protection degree IP67 EN 60529 Ambient conditions Ambient temperature range -25...+80 °C / (-13...185°F) Storage temperature range -25...+85 °C / (-13...185°F) Media temperature range -40...+100 °C / (-40...212°F) Vibration resistance 20 g; 10...500 Hz IEC60068-2-6* Shock resistance 50 g; 11 ms IEC60068-2-29 EM compatibility Disturbance emissions EN 61000-6-3 Resistance to interference EN 61000-6-2 Outputs Switching outputs 2 x PNP high-side switch Contact functions NO / NC contact; window / hysteresis Switching current: 0.5 A / switch to 85 °C; / (185°F) 0,7 A / switch to 70 °C / (158°F) Response speed 0.7 s maximum load current Optional analogue output Measuring range 0/4...20 mA Response speed (0-95 %) 300 ms Analogue output error ± 1 % FS Load 500 from V+ > 18 VDC The Controller Family 75 Catalogue 4083/UK SCTSD high pressure TemperatureController 73.4 M12 connecting plug SCTSD-150-x4-05 46.3 39.5 SensoControl I II UNIT °C/°F 93 Pin assignment SCTSD-150-02-07 2 switching outputs M12x1; 4-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out SW27 ø32 O-Ring 7.65x1.78 Ø7 M10x1 9 18.5 SCTSD-150-12-07 1 switching output, 1 analogue output M12x1; 4-pole PIN Assignment 1 V+ 2 Analogue out 3 0 V / GND 4 S1 out SCTSD-150-12-05 2 switching outputs, 1 analogue output M12x1; 5-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out 5 Analogue out The Controller Family Measuring range Display resolution Increment size -40...100 °C / (-40...212°F) 0.1 °C / (32.2°F) Lowest reset switch point RSP -40 °C / (-40°F) Largest switching value SP 100 °C / (212°F) Smallest adjustable difference between SP and RSP (SP-RSP) 0.8 / (33.4°F) 76 Catalogue 4083/UK SCTSD high pressure TemperatureController Order code SCTSD high pressure 2 switch outputs; no analogue output M12x1 connecting plug; 4-pole SCTSD-150-02-07 1 switch output; with analogue output SCTSD-150-12-07 M12x1 connecting plug; 4-pole 2 switch outputs; with analogue output SCTSD-150-12-05 M12x1 connecting plug; 5-pole Accessories PC Programming Kit SCSD-PRG-KIT Connection cable and single plug Connection cable, assembled (open cable end) SCK-400-xx-xx Cable length (m) 2 m 02 5 m 05 10 m 10 Connecting plug M12 cable jack; straight 45 M12 cable jack; 90° angled 55 Single connector M12 cable jack; straight M12 cable jack; 90° angled SCK-145 SCK-155 The Controller Family 77 Catalogue 4083/UK SCTSD-L combination switch Device features Compact design Temperature display Individually adjustable temperature switching outputs Small switching hysteresis Preset For standard oils For cooling For switching off (Tmax) Fixed level contacts Only one float Preset level Warning and shutdown min. Shut-down min./max. Up to one meter probe length 1 2 3 4 The SCTSD-L combination switch was designed to meet the requirements of hydraulic facility construction. It combines the functions of a fixed mechanical level switch with an adjustable temperature switch with display. Level The tank level is measured using a highly dynamic, fully encapsulated magnetic float which switches the bi-stable reed contacts. The M12 pin assignments are compatible with conventional existing systems. The level contacts are pre-determined according to the normal tank sizes. There are two standard switch output versions available: Warning minimum level and shutdown minimum level Shutdown maximum and minimum levels The switching positions were chosen according to the proven experiences of plant constructors and the DIN. For safety reasons (fail-safe / closed circuit), the switching behaviour of the standard switch is an NC contact. Optionally the contacts can be changed at the factory and pre-set in line with the customer's requirements. Temperature The temperature is detected using a sensor; it is then evaluated and constantly displayed using the SCTSD TemperatureController (as described in the SCTSD section). Thanks to the easy switching functions (e.g. switching windows), intelligent switching settings can be achieved that are not possible using a mechanical temperature switch. Normally the outputs for the normal temperature functions cooling on/off and shutdown are pre-installed as standard. The temperature thresholds were designed for standard oils (HLP). It is possible to adjust the temperature monitoring temperature limits (e.g. cooling and shutdown) for each output individually using the keys: On/off switching temperature limits NO/NC contact Hysteresis / window function Time delay and attenuation Optional (see: SCTSD-L-....-KIT5 ) 3 different versions of temperature switching outputs are available: 2 switching outputs 1 switching and 1 analogue output 2 switching outputs and one analogue output 78 Catalogue 4083/UK The Controller Family SCTSD-L combination switch Technical data General Measurement principle Float Viscosity Density Connector thread Protection tube Probe length Lmax Operating pressure Accuracy Material Protection tube Connector thread Ambient conditions Temperature of substance Storage temperature Magnetic float reed switches NBR, Ø 18 mm, length 25 mm, magnetic Max. 250 cSt at 25 °C at least 0.750 g/cm³ G3/4 outer thread Ø 8 mm Lowest switching point + 35 mm 1 bar max. ±2 mm Brass Brass -20...+85 °C / (-4...185°F) -40...+100 °C / (-40...212°F) Fill level pin assignments M12x1; 4-pole PIN Assignment 1 IN 2 OUT S2 3 n.c.* 4 OUT S1 *n.c. = do not connect Preset temperatures Switching output 1* 50 °C (122°F) contact closed (cooling on) 45 °C (113°F) contact open (cooling off) Switching output 2* 63 °C (145°F) contact open (shutdown) 60 °C (140°F) contact closed Level switching outputs Switching current: 0.5 A max. Switching voltage 100 V max. Switching power 10 W max. Switching function NO or NC (bi-stable) Contact material Rhodium Plug M12x1; 4 pin Smallest difference between 30 mm L1 and L2 Smallest switching position L1 30 mm from the tank lid *) Each temperature switching output can be individually re-programmed or adjusted: NO/NC contact On/off switching temperature Hysteresis / window function Time delay and attenuation The Controller Family 79 Catalogue 4083/UK The Controller Family SCTSD-L combination switch Temperature pin assignment SCTSD-150-0X-0X (Refer chapter SCTSD) SCTSD-L-xxxxO-xxFO SCTSD-L-xxxxx-xxxxx-KIT5 2 switching outputs M12x1; 4-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out SCTSD-L-xxxxx-xxxxx-17-KIT5 1 switching output, 1 analogue output M12x1; 4-pole PIN Assignment 1 V+ 2 Analogue out 3 0 V / GND 4 S1 out SCTSD-L-xxxxO-xxFO SCTSD-L-xxxxx-xxxxx-15-KIT5 2 switching outputs, 1 analogue output M12x1; 5-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out 5 Analogue out 80 Catalogue 4083/UK SCTSD-L combination switch Order code Combination switch Combination switch Marine (approved by DNV/GL/ABS) 2 level outputs, temperature display 2 temperature switching outputs SCTSD-L-xxxxx-xxxxxQ2 SCTSD-L-xxxxx-xxxxx-MAQ2 Combination switch SCTSD-L-xxxxx-xxxxx-1xQ2 Combination switch Marine SCTSD-L-xxxxx-xxxxx-1x-MAQ2 (approved by DNV/GL/ABS) 2 level outputs, temperature display 1 temperature-analogue output (0/4..20 mA) Length (L1 mm)* min. 40 mm / max. 950 mm xxx Version Falling closing Falling open Rsing closing Rising open Length (L2 in mm)* min. 40 mm / max. 950 mm FC FO RC RO xxx Version Falling closing FC Falling open FO Rising closing RC Rising open RO Plug-in connection M12; 4-pole (1 temperature switching output) 7 M12; 5-pole (2 temperature switching outputs) 5 Q2: Minimum order qty. 5 pcs. *Switching output 1 (L1) can be above or below switching output 2 (L2) L1 and L2 are multiples of 10 mm Smallest difference between L1 and L2 = 30 mm The Controller Family 81 Catalogue 4083/UK SCLSD LevelController Device features Proven measuring system Level display mm / inch / % display High and low display Analogue output Switching outputs No surge pipe necessary Replacement for several mechanical switches Pivoting 1 2 3 4 The LevelController combines the functions of a level switch, a level sensor and a level display. Level display (inspection glass) Switching outputs Analogue signal The LevelController is ideal for the monitoring tank contents. Reliable and safe The position of the float is finely ( 5 mm) and continuously recorded and shown in the display in mm or inch. Through this continuous recording, the danger of individual mechanical contacts "sticking" no longer exists. Therefore the operational reliability of the monitored plant is increased. Parameters can be password protected to avoid unauthorised changes. Easy to use The parameters are set using the keys or over a programming module. High functionality Each switching output can be adjusted individually: NO/NC contact Upper and lower level switching point Delay times Hysteresis / window function Attenuation The analogue output is individually adjustable: 0/4...20 mA switchable Upper level adjustable Lower level adjustable Everything at a glance The display can be read from long distances. Using the selectable percent display the full level is uniformly displayed independent of the tank shape. An offset can also be entered (difference from the sensor to the tank bottom) to give a realistic indication of the level from the tank bottom. Different uses can easily be implemented or corrected at a later date using the menu-driven level switching points. As the switching point no longer needs to be specified at the time of order, the versions of mechanical level switches required is reduced. Universal Thanks to these easy switching functions (hysteresis and window functions, NC or NO functions), intelligent adjustments can be set which are normally not possible using a mechanical level switch. Therefore, many switches can be replaced with one controller. With the optional analogue output, the level and temperature can be monitored easily with a controller (e.g. for leakage monitoring). The Controller Family 82 Catalogue 4083/UK SCLSD LevelController Application example: Tank temperature monitoring Since the conventional specifications for mechanical level switches (the mm data from the tank lid) are often used during project planning, these data are selected here for a practical example. SensoControl I II UNIT mm/inch % Facility off If the tank level falls below 310 mm (measured from the tank top / dry run) or climbs above 70 mm (measured from MAX the tank top / overflow), switch off should occur. A protective wire-break mechanism should be considered to improve safety. Automatic tank filling If the tank level falls below 240 mm (measured from the MIN tank top), the tank should be automatically filled to 110 mm (measured from the tank top) with a pump. Measurement display Display in mm without offset SCLSD370 High 330 40 Low Resulting switch value for a SCLSD-370 mm Stop above: 370 mm - 70 mm = 300 mm Stop below: 370 mm - 310 mm = 60 mm Window function, NO contact The output S1 is closed, if the level is between 300 and 60 mm. Load stop: 370 mm - 110 mm = 260 mm Load on: 370 mm - 240 mm = 130 mm Hysteresis function, NC contact If the level falls below 130 mm, the contact closes and opens again when 260 mm is exceeded. Length in mm from lower edge to level sensor The Controller Family SP1 = 300 mm SP2 = 260 mm rSP2 = 130 mm rSP1 = 60 mm Tank level Facility On / Off Switching output 1 SP1 = 300 mm rSP1 = 60 mm Window function / NO contact Fill tank Switching output 2 SP2 = 260 mm rSP2 = 130 mm Hysteresis NC contact Facility On Off Fill tank On Off The output S1 is closed if the level is between 300 and 60 mm. If the level falls below 130 mm, the contact closes and opens again when 260 mm is exceeded. Time 83 Catalogue 4083/UK SCLSD LevelController Device features Everything at a glance Sloped display Digital display Large Illuminated Display mm, inch, or % Actual level High and low display Switching points Rugged Metal housing Waterproof Excellent interference immunity Vibration proof Shock proof SensoControl I II UNIT mm/inch % Variable installation Compact size 290° pivotable G3/4 BSPP Flange for DIN Programming module Adjustable with ControllerWIN Software Optical interface Switch status is shown Easy to use 3 large buttons Display of the unit Connect as required 2 switching outputs Analogue output 0...20 or 4...20 mA Freely programmable Scalable M12 connecting plugs No surge pipe necessary Electronic attenuation adjustable attenuation Proven measuring system High float dynamics Small design Universal usage The Controller Family 84 Catalogue 4083/UK SCLSD LevelController Technical data Input parameters Measuring component Connector thread Parts in contact with substances Temperature range of substance Output values Switching point accuracy Display accuracy Response speed Resolution Float Material Dimensions Viscosity Density Level rod Material Dimensions Operating pressure Electrical connection Supply voltage V+ Electrical connection Short-circuit protection Protection against wrong insertion Overload protection Current consumption Resistance reed chain with float G3/4 BSPP; nickel-plated brass; ED soft seal NBR* Brass; nickel-plated brass; NBR* -20...+85 °C / (-4...185°F) ± 1 % FS at 25 °C (77°F) ± 1 % FS ± 1 Digit at 25 °C (77°F) 700 ms 7.5 mm NBR Ø 18 mm, Length 35 mm Max. 250 cSt at 25 °C (77°F) at least 0.750 g/cm³ Stainless steel Ø 8 mm 1 bar 15...30 VDC nominal 24 VDC; Protection class 3 M12x1; 4-pole; 5-pole; with gold-plated contacts Yes Yes Yes < 100 mA Housing Adjustable direction to 290°C Material Die-cast zinc Z 410; painted Foil material Polyester Display 4-digit 7-segment LED; red; digit height 9 mm Protection degree IP67 DIN EN 60529 Ambient conditions Ambient temperature range -20...+85 °C / (-4...185°F) Storage temperature range -40...+100 °C / (-40...212°F) EM compatibility Disturbance emissions EN 61000-6-3 Resistance to interference EN 61000-6-2 Outputs Switching outputs Two MOSFET high-side switches (PNP) Contact functions NO / NC contact; window / hysteresis function freely adjustable Switching voltage Switching current max. V+ -1.5 VDC 0.5 A per switch Short-circuit current 2.4 A per switch Analogue output 0/4...20 mA; programmable; freely scalable RL (power supply- 8 V)/ 20 mA ( 500 ) * different sealing material (FKM, EPDM etc.) upon request The Controller Family 85 Catalogue 4083/UK SCLSD LevelController Display possibilities Example of a percent display SensoControl I II UNIT mm/inch % = = UNIT = SCLSD-XXX SET1 Max Example of a mm display SensoControl I II UNIT mm/inch % SCLSD- 250 370 520 Length of 250 mm 370 mm 520 mm sensor High range 40 mm Display in mm with Offset SCLSD250 370 520 High High High 210 330 480 Display in mm with Offset 200 mm SCLSD250 370 520 High High High 410 530 680 SET0 170 mm 290 mm 440 mm Measurement display Activer range Min Low range 40 mm 40 40 40 Low Low Low 240 240 240 Low Low Low Offset = 200 mm L1 L2 Sensor length active range Measurement range 250 mm 40...210 mm 370 mm 40...330 mm 520 mm 40...480 mm 800 mm 40...760 mm 1000 mm 40...960 mm Display resolution Increment size 1 mm 1 mm 1 mm 1 mm 1 mm Increment size 5 mm 5 mm 5 mm 10 mm 10 mm Lowest reset Largest switch- Smallest adjustable switch point ing value difference between RSP SP SP and RSP (SP-RSP) 40 mm 210 mm 5 mm 40 mm 330 mm 5 mm 40 mm 480 mm 5 mm 40 mm 760 mm 10 mm 40 mm 960 mm 10 mm Pin assignment SCLSD-xxx-00-07 2 switching outputs; M12x1; 4-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out SCLSD-xxx-10-07 1 switching output, 1 analogue output, M12x1; 4-pole PIN Assignment 1 V+ 2 Analogue out 3 0 V / GND 4 S1 out The Controller Family 86 Catalogue 4083/UK SCLSD LevelController 39.5 SensoControl I II UNIT mm/inch % SW32 hex.32 EDSealing G3/4 ø32 13.5 91.5 <40 SensoControl I II UNIT mm/inch % L1 L2 L1 ø8 L1 = length of the sensor (mm) L2 = active range (mm) SCLSD-xxx-10-05 2 switching outputs, 1 analogue output M12x1; 5-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out 5 Analogue out Order code SCLSD LevelController 2 switching outputs; 2 switching outputs Marine; (approved by DNV/GL/ABS) no analogue output M12x1 connecting plug; 4-pole 1 switching output; 1 switching output Marine; (approved by DNV/GL/ABS) with analogue output M12x1 connecting plug; 4-pole 2 switching outputs; 2 switching outputs Marine; (approved by DNV/GL/ABS) with analogue output M12x1 connecting plug; 5-pole Length (Installation length L1 mm) 250 mm 370 mm 520 mm 800 mm 1000 mm SCLSD-xxx-00-07 SCLSD-xxx-00-07-MA SCLSD-xxx-10-07 SCLSD-xxx-00-07-MA SCLSD-xxx-10-05 SCLSD-xxx-10-05-MA 250 370 520 800 1000 Accessories PC Programming Kit Flange adapter 6-hole connection DIN 24557, part 2 SCSD-PRG-KIT SCAF-3/4-90 Connection cable and single plug Connection cable, assembled (open cable end) SCK-400-xx-xx Cable length (m) 2 m 02 5 m 05 10 m 10 Connecting plug M12 cable jack; straight 45 M12 cable jack; 90° angled 55 Single connector M12 cable jack; straight M12 cable jack; 90° angled SCK-145 SCK-155 The Controller Family 87 Catalogue 4083/UK SCLTSD LevelTempController Device features Proven measuring system Pivoting Level display mm / inch / % display High and low display Analogue output Switching outputs Only one hole No surge pipe necessary Replacement for several mechanical switches 1 2 3 4 1 2 3 4 With the LevelTempController,you can set up and display the temperature and the level individually using a common platform. When monitoring the tank, this integration of level and temperature functionality opens up many possibilities. The LevelTempController combines the functions of a level and temperature switch, a level and temperature sensor and a level and temperature indicator: Level and temperature display (thermometer / inspection glass) Switching outputs Analogue signal Level The position of the float is finely ( 5 mm) and continuously recorded and shown in the display in mm or inch. Because the level is continuously recorded, the danger of individual mechanical contacts "sticking" no longer exists. Therefore the operational reliability of the monitored plant is greatly increased. Using the selectable percent display, the full level is uniformly displayed for the users, independent of the tank shape. An offset can also be entered (difference from the sensor to the tank bottom) to give a realistic indication of the level from the tank bottom. Different uses can easily be implemented or corrected at a later date using the menu-driven level switching points. As the switching point no longer needs to be specified at the time of order, the versions of mechanical level switches required is reduced. Temperature The temperature in the substance is continuously recorded and displayed. The switching outputs can be individually set up just like the LevelController. Naturally all the convenient switching functions are available: window, hysteresis function and open / close as well as an analogue output for temperature. Reliable and safe Parameters can be password protected to avoid unauthorised changes. Universal Thanks to these easy switching functions (hysteresis and window functions, NC or NO functions), intelligent adjustments can be set on the LevelTempController which are normally not possible using a mechanical level switch. Therefore, many switches can be replaced with one controller. With the optional analogue outputs, the level and temperature can be monitored easily with a controller. Level: e.g. for leakage monitoring Temperature: e.g. coolers, heating, alarm, shutdown The Controller Family 88 Catalogue 4083/UK SCLTSD LevelTempController Application examples SCLSD Length in mm from lower edge to level sensor SP1 = 300 mm SP2 = 260 mm rSP2 = 130 mm rSP1 = 60 mm Tank level Application example Refer to page 83 Facility On/Off Switching output 1 SP1 = 300 mm rSP1 = 60 mm Window function/ NO contact Facility On Off Fill tank Fill tank Switching output 2 On SP2 = 260 mm rSP2 = 130 mm Hysteresis NC contact Off The output S1 is closed if the level is between 300 and 60 mm. If the level falls below 130 mm, the contact closes and opens again when 260 mm is exceeded. Time SCTSD Temperature in °C SP1 = 60 °C SP2 = 50 °C rSP2 = 40 °C rSP1 = 10 °C Tank temperature Application example Refer to page 67 Facility On/Off Switching output 1 SP1 = 60 °C/ (140°F) rSP2 = 10 °C / (50°F) Window function, NO contact Facility On Off Cooling Cooling Switching output 2 On SP2 = 50 °C/ (122°F) rSP2 = 40 °C / (104°F) Hysteresis/NO contacts Off The output S1 is closed if the temperature is between 60 °C and 10 °C. If the temperature exceeds 50 °C, the contact S2 closes and only resets at 40°C. Time The Controller Family 89 Catalogue 4083/UK SCLTSD LevelTempController Device features Everything at a glance Sloped display Digital display Large Illuminated Switching points Display level mm, inch, or % Actual level High and low display Temperature display °C, °F Current temperature Rugged Metal housing Waterproof Excellent interference immunity Vibration proof Shock proof SensoControl I II SensoControl I II UNIT mm/inch % UNIT °C/°F Variable installation A coupling hole Compact size 290° pivotable G3/4 BSPP DIN flange Programming module Adjustable with ControllerWIN Software Optical interface Switch status is shown Easy to use 3 large buttons Display of the unit Connect as required 2 switching outputs Analogue output 0...20 or 4...20 mA Freely programmable Scalable M12 connecting plugs Twin concept 2 in 1 No surge pipe necessary Electronic attenuation adjustable attenuation Level Proven measuring system High float dynamics Small design Universal usage The Controller Family Temperature sensor Integrated in the rod end 90 Catalogue 4083/UK SCLTSD LevelTempController Technical data Electrical connection Supply voltage V+ 15...30 VDC nominal 24 VDC; Protection class 3 Electrical connection M12x1; 4-pole; 5-pole; with gold-plated contacts Short-circuit protection Yes Protection against wrong Yes insertion Overload protection Yes Current consumption < 100 mA Housing Adjustable direction to 290°C Material Die-cast zinc Z 410; painted Foil material Polyester Display 4-digit 7-segment LED; red; digit height 9 mm Protection degree IP67 DIN EN 60529 Ambient conditions Ambient temperature range -20...+85 °C / (-4...185°F) Temperature range of substance 80 °C / ( 176°F) Storage temperature range -40...+100 °C / (-40...212°F) EM compatibility Disturbance emissions EN 61000-6-3 Resistance to interference EN 61000-6-2 Outputs Switching outputs Two MOSFET high-side switches (PNP) Contact functions NO / NC contact; window / hysteresis function freely adjustable Switching voltage Switching current max. V+ -1.5 VDC 0.5 A per switch Short-circuit current 2.4 A per switch Analogue output 0/4 to 20 mA; programmable; freely scalable RL (V+ - 8 V)/ / 20 mA ( 500 ) Level Input parameters Measuring component Connector thread Parts in contact with substances Temperature range of substance Output values Switching point accuracy Display accuracy Response speed Resolution Float Material Dimensions Viscosity Density Level rod Material Dimensions Operating pressure Temperature Output values Switching point accuracy Display accuracy Response speed Analogue output Resistance reed chain with float G3/4 BSPP; nickel-plated brass; ED soft seal NBR* Brass; nickel-plated brass; NBR* 80 °C / ( 176°F) ± 1 % FS at 25 °C / (77°F) ± 1 % FS ± 1 Digit at 25 °C / (77°F) 700 ms 7.5 mm NBR Ø 18 mm, Length 35 mm Max. 250 cSt at 25 °C / (77°F) at least 0.750 g/cm³ Stainless steel Ø 8 mm 1 bar ± 0.35 % FS at 25 °C / (77°F) ± 0.35 % FS ± 1 Digit at 25 °C / (77°F) 300 ms 0/4...20 mA; programmable; freely scalable; 4...20 mA = -40...125 °C / (-40...257°F) * different sealing material (FKM, EPDM etc.) upon request The Controller Family 91 Catalogue 4083/UK SCLTSD LevelTempController Display possibilities Example of a percent display Example of a mm display SensoControl I II SensoControl I II UNIT mm/inch % UNIT °C/°F = = UNIT = SET1 Max SensoControl I II SensoControl I II UNIT mm/inch % UNIT °C/°F SCLTSD- 250 370 520 Length of 250 mm 370 mm 520 mm sensor High range 40 mm Display in mm without Offset SCLTSD250 370 520 High High High 210 330 480 Display in mm with Offset 200 mm SCLTSD250 370 520 High High High 410 530 680 SET0 170 mm 290 mm 440 mm Measurement display Active range Min Low range 40 mm 40 40 40 Low Low Low 240 240 240 Low Low Low Offset = 200 mm L1 L2 Sensor length active range Measurement range 250 mm 40...210 mm 370 mm 40...330 mm 520 mm 40...480 mm 800 mm 40...760 mm 1000 mm 40...960 mm Display reso- Increment Lowest reset Largest switch- Smallest adjustable lution size switch point ing value difference between Increment size RSP SP SP and RSP (SP-RSP) 1 mm 5 mm 40 mm 210 mm 5 mm 1 mm 5 mm 40 mm 330 mm 5 mm 1 mm 5 mm 40 mm 480 mm 5 mm 1 mm 10 mm 40 mm 760 mm 10 mm 1 mm 10 mm 40 mm 960 mm 10 mm Pin assignment SCLTSD-xxx-00-07 for temperature and level 2 switching outputs; M12x1; 4-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out SCLTSD-xxx-10-07 for temperature and level 1 switching output, 1 analogue output, M12x1; 4-pole PIN Assignment 1 V+ 2 Analogue out 3 0 V / GND 4 S1 out The Controller Family 92 Catalogue 4083/UK SCLTSD LevelTempController 79.2 SensoControl I II SensoControl I II UNIT mm/inch % UNIT °C/°F 13.5 G3/4 L1 109.5 Order code SCLTSD LevelTempController 2 switching outputs; 2 switching outputs Marine; (approved by DNV/GL/ABS) no analogue output M12x1 connecting plug; 4-pole 1 switching output; 1 switching output Marine; (approved by DNV/GL/ABS) with analogue output M12x1 connecting plug; 4-pole 2 switching output; 2 switching output Marine (approved by DNV/GL/ABS) with analogue output M12x1 connecting plug; 5-pole Installation length (L1 mm) 250 mm 370 mm 520 mm 800 mm 1000 mm SCLTSD-xxx-00-07 SCLTSD-xxx-00-07-MA SCLTSD-xxx-10-07 SCLTSD-xxx-10-07-MA SCLTSD-xxx-10-05 SCLTSD-xxx-10-05-MA 250 370 520 800 1000 ø8 L1 = length of the sensor (mm) L2 = active range (mm) Accessories PC Programming Kit Flange adapter 6-hole connection DIN 24557, part 2 SCSD-PRG-KIT SCAF-3/4-90 Connection cable and single plug Connection cable, assembled (open cable end) SCK-400-xx-xx Cable length (m) 2 m 02 5 m 05 10 m 10 SCLTSD-xxx-10-05 for temperature and level 2 switching outputs, 1 analogue output; M12x1; 5-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out 5 Analogue out Connecting plug M12 cable jack; straight M12 cable jack; 90° angled Single connector M12 cable jack; straight M12 cable jack; 90° angled 45 55 SCK-145 SCK-155 The Controller Family 93 Catalogue 4083/UK SCOTC OilTankController Device features Proven measuring system Level and temperature display mm / inch / % display High and low display Only one hole Continuous level measurement Connection Filling coupling Air filter Low pressure No surge pipe necessary 1 2 3 4 1 2 3 4 In addition to the LevelTempController, the OilTankController also offers standardised connections for an air filter and a fill coupling. When monitoring the tank for series use, this integration of level and temperature functionality together with air filter and fill adapter port opens up many possibilities. An additional connecting hole is required for the four functions. The OilTankController combines the functions of a level and temperature switch, a level and temperature sensor and a level and temperature display: Level and temperature display (thermometer / inspection glass) Switching outputs Analogue signal Level The position of the float is finely ( 5 mm) and continuously recorded and shown in the display in mm or inch. Because the level is continuously recorded, the danger of individual mechanical contacts "sticking" no longer exists. Therefore the operational reliability of the monitored plant is greatly increased. Using the selectable percent display, the full level is uniformly displayed for the users, independent of the tank shape. An offset can also be entered (difference from the sensor to the tank bottom) to give a realistic indication of the level from the tank bottom. Different uses can easily be implemented or corrected at a later date using the menu-driven level switching points. As the switching point no longer needs to be specified at the time of order, the versions of mechanical level switches required is reduced. Temperature The temperature in the substance is continuously recorded and displayed. The switching outputs can be individually set up just like the LevelController. Naturally all the convenient switching functions are available: window, hysteresis function and open/close as well as an analogue output for temperature. Reliable and safe Parameters can be password protected to avoid unauthorised changes. Universal In combination with the comfortable switch functions like hysteresis and window function, open/close contact functions LevelTempController intelligent settings can be made which are not possible with a mechanical level/ temperature switch. Therefore, many switches can be replaced with one controller. With the optional analogue outputs, the level and temperature can be monitored easily with a controller. Level: e.g. for leakage monitoring Temperature: e.g. coolers, heating, alarm, shutdown The Controller Family 94 Catalogue 4083/UK SCOTC OilTankController Application examples SCLSD Length in mm from lower edge to level sensor SP1 = 300 mm SP2 = 260 mm rSP2 = 130 mm rSP1 = 60 mm Tank level Application example Refer to page 83 Facility On/Off Switching output 1 SP1 = 300 mm rSP1 = 60 mm Window function/ NO contact Facility On Off Fill tank Fill tank Switching output 2 On SP2 = 260 mm rSP2 = 130 mm Hysteresis NC contact Off The output S1 is closed if the level is between 300 and 60 mm. If the level falls below 130 mm, the contact closes and opens again when 260 mm is exceeded. Time SCTSD Temperature in °C SP1 = 60°C SP2 = 50°C rSP2 = 40°C rSP1 = 10°C Tank temperature Application example Refer to page 67 Facility On / Off Facility Switching output 1 On SP1 = 60 °C/ (140°F) rSP2 = 10 °C / (50°F) Window function, NO Off contact Cooling Cooling Switching output 2 On SP2 = 50 °C/ (122°F) rSP2 = 40 °C / (104°F) Hysteresis/NO contact Off The output S1 is closed if the temperature is between 60 °C and 10 °C. If the temperature exceeds 50 °C, the contact S2 closes and only resets at 40°C. Time The Controller Family 95 Catalogue 4083/UK SCOTC OilTankController Device features Getting to the point Compact construction (4 in 1) Easy adjustment of the switching points using the menu Analogue output Safety control Cost savings in the logistics, assembly and maintenance Level and temperature Display Adjustable switching output Analogue output The extended version with safety control Additional fixed switching contacts Level min/max Temperature too high Real fill level The level controller continuously measures the position of the float and continuously shows the position in the display. Up to 1000 mm No surge pipe necessary Electronic attenuation adjustable attenuation Temperature sensor Integrated in the rod end 6-hole standard for Ventilation filter* (DIN 24557, part 2) G3/4 BSPP for Filling coupling* G1/8 BSPP for Low pressure switch* Clogging indicator* 6-hole standard for Tank connection (DIN 24557, part 2) Filling tube No whirl-up Whirl-up protection Programming module Adjustable with ControllerWIN Software The Controller Family *Venting filter, filling coupling, low pressure switch and clogging indicator are not included in the delivery. 96 Catalogue 4083/UK SCOTC OilTankController Technical data SCOTC Tank installation length Adjustment range 250 250 mm 40...210 mm 370 370 mm 40...330 mm 520 520 mm 40...480 mm 800 800 mm 40...760 mm 1000 1000 mm 40...960 mm Electrical connection Supply voltage V+ 15 to 30 VDC nominal 24 VDC; Protection class 3 Electrical connection M12x1; 4-pole; 5-pole; with gold-plated contacts Short-circuit protection Yes Protection against wrong Yes insertion Overload protection Yes Current consumption < 100 mA Housing Material Die-cast zinc Z 410; painted Aluminium Foil material Polyester Display 4-digit 7-segment LED; red; digit height 9 mm Protection degree IP67 DIN EN 60529 Ambient conditions Ambient temperature range -20...+80 °C / (-4...176°F) Temperature range of substance 80 °C / ( 176°F) Storage temperature range -40...+100 °C / (-40...212°F) Sampling period 300 ms Display refresh 1 s EM compatibility Disturbance emissions EN 61000-6-3 Resistance to interference EN 61000-6-2 Outputs Switching outputs Two MOSFET high-side switches (PNP) Contact functions NO / NC contact; window / hysteresis function freely adjustable Switching voltage Switching current max. V+ -1.5 VDC 0.5 A per switch Short-circuit current 2.4 A per switch Optional analogue output Measuring range 0/4...20 mA; programmable Response speed (0 to 95%) 300 ms Error ± 1 % FS Load 500 from Vb > 18 VDC Level Input variables Measuring component Reed chain resistance Connector thread 6 hole standardDIN 24557, part 2 Output variables Switching point accuracy ± 1 % FS at 25 °C Display accuracy ± 1 % FS ± 1 Digit at 25 °C Response speed 700 ms Resolution 5 mm...520 mm; 10 mm > 520 mm Float Material Polypropylene Dimensions Ø 35 mm, Length 40 mm Level rod Material Brass Dimensions Ø 12 mm Operating pressure 1 bar max. Optional Lo-Hi contact (S3 out) Alarm contact In series switched Lo and Hi NC contact Maximum load current 0.7 A Temperature Input variables Sensor element PT1000 Filling tube Response time Ø 18x1 mm 0.9 = 60 s Output variables Switching point accuracy ± 0.5 % FS at 25 °C / (77°F) Display accuracy ± 0.5 % FS ± 1 Digit at 25 °C / (77°F) Response speed 300 ms Analogue output 0/4...20 mA; programmable; freely scalable; 4...20 mA = -40...125 °C / (-40...257°F) Optional temperature switch (S3 out) Alarm contact with > 65 °C Open contact Maximum charging current 0.7 A The Controller Family 97 Catalogue 4083/UK SCOTC OilTankController Pin assignment Without safety-control-output SCOTC-xxxx-00-07 for temperature and level 2 switching outputs M12x1; 4-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out SCOTC-xxxx-10-07 for temperature and level 1 switching outputs, 1 analogue output M12x1; 5-pole PIN Assignment 1 V+ 2 Analogue out 3 0 V / GND 4 S1 out SCOTC-xxxx-10-05 for temperature and level 2 switching outputs, 1 analogue output M12x1; 5-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out 5 Analogue out With safety-control-output SCOTC-xxxx-00-05 Level: Two variable switching outputs, One fixed safety-control-output level min/max; M12x1; 5-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out 5 S3 out (L-Low / L-High) SCOTC-xxxx-00-05 Temperature: Two variable switching outputs, One fixed safety-control-output temperature max. 65 °C M12x1; 5-pole PIN Assignment 1 V+ 2 S2 out 3 0 V / GND 4 S1 out 5 S3 out (T-High) L1 Sensor length Measurement range 250 mm 370 mm 520 mm 800 mm 1000 mm L2 active range 170 mm 290 mm 440 mm 720 mm 920 mm Display resolu- Increment tion increment size size 1 mm 5 mm 1 mm 5 mm 1 mm 5 mm 1 mm 10 mm 1 mm 10 mm Lowest reset switch point RSP 40 40 40 40 40 Largest switch- Smallest adjustable ing value difference between SP SP and RSP (SP-RSP) 210 5 mm 330 5 mm 480 5 mm 760 10 mm 960 10 mm The Controller Family 98 Catalogue 4083/UK SCOTC OilTankController 110 90 SensoControl G3/4 95 G1/8 40 M5 L2 L1 73 M5 L1 = length of the sensor (mm) L2 = active range (mm) Order code SCOTC OilTankController * 2 switching outputs; no analogue output SCOTC-xxxx-00-07 M12x1 connecting plug; 4-pole 2 switching outputs; with analogue output SCOTC-xxxx-10-07 M12x1 connecting plug; 4-pole 1 switching output; with analogue output SCOTC-xxxx-10-05 M12x1 connecting plug; 5-pole 3 switching outputs; no analogue output SCOTC-xxxx-00-05 M12x1 connecting plug; 5-pole with safety control Length (Installation length L1 mm) 250 mm 370 mm 520 mm 800 mm 1000 mm 250 370 520 800 1000 Accessories PC Programming Kit SCSD-PRG-KIT Connection cable and single plug Connection cable, assembled (open cable end) SCK-400-xx-xx Cable length (m) 2 m 02 5 m 05 10 m 10 Connecting plug M12 cable jack; straight 45 M12 cable jack; 90° angled 55 Single connector M12 cable jack; straight M12 cable jack; 90° angled SCK-145 SCK-155 The Controller Family *Venting filter, filling coupling, low pressure switch and clogging indicator are not included in the delivery. 99 Catalogue 4083/UK Accessories SCK cable Device features One cable for all Compact size Interference-free Compatible to: Sensors Controllers M12 plug DIN EN 175301 (Device plug) Available in a variety of lengths The SensoControl® cable was designed for use with the Pin assignment industrial sensors and switches. Thus the M12 cable and M12 plug are SCK-400-xx-x5 Compact Shielded Five-pole PIN 4 3 1 bn 2 wh 5 3 bu 5-pole version 1 The 5-pole cable is suitable for both 4-pole and 5-pole 2 4 bk 5 gy connections. The sensor variants with a 4-pole connector are fully compatible with the 5-pole cable. SCK-400-xx-56 So despite different pin counts on the pressures switch (Controller Family SCxSD and SCOTC) and sensors, it is always possible to use just one cable version (5-pole) regardless of the plug version. PIN 1 ye 2 gn 3 bn The SCK-400-xxx-x5 cables fit to all components in this catalogue using M12 connectors. Shielding Shielding protects against interference and ensures improved operational safety. Higher EMC protection brown white blue black grey braun weiß blau schwarz grau yellow green brown gelb grün braun 100 Catalogue 4083/UK 29.5 Accessories SCK cable Connection cable SCK-400-xx-45 SCK-400-xx-55 SCK-400-xx-56 26.5 Ø14.5 Single connector SCK-006 (Device plug) 41.5 ~45 38.5 27.5 Ø14.5 ~45 29.5 27.5 Single connector SCK-145 56 SCK-155 54 Ø20 37 Ø20 Connection cable and single plug Connection cable, assembled (open cable end) SCK-400-xx-xx Cable length (m) 2 m 02 5 m 05 10 m 10 Connecting plug M12 cable jack; straight 45 M12 cable jack; 90° angled 55 Cable socket DIN EN 175301-803 Form A 56 (old DIN 43650) Single connector M12 cable jack; straight M12 cable jack; 90° angled Cable socket DIN EN 175301-803 Form A (old DIN 43650) SCK-145 SCK-155 SCK-006 101 Catalogue 4083/UK Accessories SCA adapter SCA-1/4 reduction adapter The SCA-1/4 provides compatibility for earlier sensor SCA-1/4-M22x1.5-ED versions with the hydraulic connection M22x1.5 or G1/2 SCA-1/4-ED-1/2-ED BSPP. L1 When replacing earlier versions This allows facilities to be updated without major planning overhead. L4 S1 ØD4 T1 T2 X1) X1) EOLASTIC-seal T1 T2 ØD4 L1 L4 S1 Weight (g/1 St) PN (bar)1) DF ** SCA-1/4-M22x1.5-ED M22x1.5 G1/4 BSPP 27 24 14 27 56 400 4 SCA-1/4ED1/2-ED G1/2 BSPP G1/4 BSPP 27 24 14 27 56 400 4 SCA-1/4 attenuation adapter System-related pressure spikes are reduced with the SCA-1/4-EDX-1/4-D. SCA-1/4-EDX-1/4-D L1 Attenuation for pressure peaks L4 S1 The G1/2 BSPP version ensures compatibility for earlier sensor versions to the G1/2 BSPP hydraulic connection. When replacing earlier versions ØD4 T1 T2 X2) X1) X1) EOLASTIC-seal T1 T2 ØD4 L1 L4 S1 Weight (g/1 St) PN (bar)1) DF ** SCA-1/4EDX1/4-D G1/4A BSPP G1/4 BSPP 19 34 12 22 61 630 3.5 102 Catalogue 4083/UK T2 L3 L1 Accessories SCA adapter SCPSD flange adapter SCAF-1/4-40 for mechanical pressure switch When replacing existing mechanical pressures switches SCAF-1/4-40 with 40x40mm flange connections L1 L3 L2 T1 SCAF-1/4-40 for mechanical pressure switch SCAF-1/4-40 T1 T2 L1 L2 L3 Weight (g/1 St) PN (bar)1) Alu DF ** G1/4 BSPP 5.5 40 20 31 15 400 4 SCLSD/SCLTSD flange adapter SCAF-3/4-90 6-hole connection DIN 24557, part 2 For LevelController and LevelTemp Controller (SCLSD SCAF-3/4-90 and SCLTSD), a compatibility to the tank connections L1 6-hole DIN 24557, part 2, is ensured. L3 L2 T1 T2 6x60° SCAF-3/4-90 6-hole connection DIN 24557, part 2 T1 T2 L1 G3/4 BSPP 5.5 90 SCAF-3/4-90 L2 L3 10 73 Weight (g/1 St) 520 Material Nickel-plated brass ** DF = Design Factor (safety factor) 103 Catalogue 4083/UK Accessories ControllerWIN software Device features Suitable for the Controller Family Simple adjustment of all parameters Saving of the parameters Adjustment with PC/laptop at the workbench at the desk in the plant The ControllerWIN software allows the adjustment and saving of all parameters, including: Switching points NO / NC contact function Window / hysteresis Scaling of the analogue output Passwords Function A no-contact infra-red interface is used to compare the data with the corresponding functional controller. This can take place directly in the facility or externally using a power supply unit (not included in the delivery). It is not necessary to disconnect the power supply or pull the cable out (operations are not interrupted). From the Controller Family product series: SCPSD SCTSD SCLSD SCLTSD SCOTC A programming adapter is connected to the corresponding controller and the data is transmitted to a PC. The SCSD-PRG_KIT programming kit includes all components (adapter, software and power supply) required for adjusting the controller with the PC or laptop: At the workbench At the desk In the plant Application Saving and logging the adjusted values Programming multiple controllers Easy exchange of existing controllers The programming kit is the ideal solution in each of these cases. 104 Catalogue 4083/UK ControllerWIN software Technical data System requirements Operating system WIN 98/2000/ME/NT/XP PC / laptop connection RS232 (USB using conventional adapter) Controller connection Parker infra-red interface SCxSD/SCOTC Accessories Accessories for: PressureController SensoControl SensoControl I II I II bar/PSI bar/PSI UNIT UNIT TemperatureController LevelController LevelTempController OilTankController SensoControl I II SensoControl I II UNIT °C/°F UNIT °C/°F SensoControl I II UNIT mm/inch % SensoControl I II UNIT mm/inch % SensoControl I II SensoCIontrolII SensoControl I II SensoControl UNIT mm/inch % mm/inch % °C/°F UNIT UNIT UNIT I II SensoControl °C/°F SensoControl Pressure display and monitoring Temperature display and Level indication and Level and temperature display and 40 40 monitoring monitoring monitoring Order code PC Programming KIT 105 L2 L2 L1 L1 SCSD-PRG-KIT Catalogue 4083/UK Installation and safety instructions Pressure / bar Installation and safety instructions The CE mark indicates a high-quality device that complies with the European directive 89/336/EWG and EMVG. The sensor will be damaged if the data sheet specifications and maximum recommended feed voltage levels are exceeded! We confirm that these products comply with the following standards: EMC Electromagnetic emission: Electromagnetic immunity: EN 61000-6-3 EN 61000-6-2 Important Electromagnetic disturbances can affect the desired signal. Apply all general EMC strategies when planning facilities and machines. We recommend using shielded cables (SCK400-xx-x5) in order to achieve better EMC immunity. Make sure you route analogue and data cables so that there is a sufficient gap between them. An effective earthing strategy will help you to avoid measuring errors. Always connect metal housings with the reference ground. The PE protective earth should have a low-ohm connection. According to VDE 0701, the PE resistance must be measured. Compatibility with media (substances) SensoControl® products which come into contact with the substance are not produced in an oil-free or fat-free environment. Therefore these products are not suitable for use in applications which use explosive mixtures of oil and gas (e.g. oxygen or compression). This could lead to a danger of explosion! Danger of explosion! Only use substances which are compatible with the components that come into contact with the substance. (Refer to the data sheets) Please consult with the plant manufacturer or the manufacturer of the substance if you have any questions. (Refer to catalogue 4100 chapter C). Pressure range selection PO Power feed voltage Pressure Each sensor series specifies the recommended feed voltage to used when operating the standard sensor. We recommend using a low-noise, high-quality, constant voltage source. Certain specifications (such as sensitivity and thermal sensitivity shift) may change when other power feeds are used. Each sensor is trimmed to its peak performance. The sensor's performance may change when other power feed types are used. Make sure you comply with the polarity and earthing regulations. Improperly connected feed wires can damage sensors and amplifiers! If one pole of the sensor feed is automatically earthed via the sensor's processing system, then you should avoid an additional earth on the sensor signal wire. This would cause the sensor to short circuit and damage the sensor. Do not apply feed-in voltage to the output wires. This will permanently damage the sensors! PN Time / ms When selecting pressure components, ensure that the overload pressure Pmax will not be exceeded. It is possible that the pressure cell can be deformed when the overload pressure Pmax is exceeded (depending on the duration, frequency and level of the pressure spike). Note: The "diesel effect" caused by entrapped air can result in pressure spikes that far exceed the maximum pressure. The nominal pressure PN of the pressure component (sensor/switch) should be higher than the nominal pressure of the system to be measured. 106 Catalogue 4083/UK Appendix Temperature conversion table Celsius to Fahrenheit °C °F 150 302 145 293 140 284 135 275 130 266 125 257 120 248 115 239 110 230 105 221 100 212 95 203 90 194 85 185 80 176 75 167 70 158 65 149 60 140 55 131 50 122 45 113 40 104 35 95 30 86 25 77 20 68 15 59 10 50 5 41 0 32 -5 23 -10 14 -15 5 -20 -4 -25 -13 -30 -22 -35 -31 -40 -40 -45 -49 -50 -58 Fahrenheit to celsius °F °C 340 171 330 166 320 160 310 154 300 149 290 143 280 138 270 132 260 127 250 121 240 116 230 110 220 104 210 99 200 93 190 88 180 82 170 77 160 71 150 66 140 60 130 54 120 49 110 43 100 38 90 32 80 27 70 21 60 16 50 10 40 4 30 -1 20 -7 10 -12 0 -18 -10 -23 -20 -29 -30 -34 -40 -40 -50 -46 -60 -51 Pressure conversion table bar to psi bar 1000 800 600 500 400 250 160 100 60 40 35 25 16 10 6 4 2.5 1.6 1 psi 14505 11604 8703 7253 5802 3626 2321 1451 870 580 508 363 232 145 87 58 36 23 15 psi to bar psi bar 10000 689 9000 620 7000 483 6000 414 4000 276 3000 207 2500 172 1000 69 900 62 600 41 500 34 400 28 250 17 150 10.3 100 6.9 90 6.2 60 4.1 40 2.8 25 1.7 10 0.7 Examples Temperature conversion Initial value: 100 °C in °F: 212 °F °F in °C: 37.78 °C Pressure conversion Initial value: 35 bar in psi: 507.675 psi psi in bar: 2.41296 bar Appendix 107 Catalogue 4083/UK Appendix Index SCxSD SC-910 SC-911 SC-912 SCA-1/4EDX1/2-ED SCA-1/4EDX1/4-D SCA-1/4-M22x1.5-ED SCAF-1/4-40 SCAF-3/4-90 SCAQ-150 SCAQ-GI-R1/2 SCA-TT-10-1/2 SCA-TT-10-xxx SCFT-... SCK-006 SCK-145 SCK-155 SCK-400-... SCK-410-03-45-45 SCLSD-... SCLTSD-... SCOTC-... SCP01-... SCP02-... SCP03-... 52-53 41 41 41 102 102 102 103 103 41 41 72 72 42-45 101 101 101 100 73 82-87 88-93 94-99 12-15 16-21 22-26 SCP07 SCP08 SCPSD-... SCPSDi-... SCPSi SCQ-150-10-07 SCSD-PRG-KIT SCSD-S27 SCT-150-... SCTSD-150-... SCTSD-L-... SCTT-10-xxx-07 SCTT-20-10-07 SCVF-... 27-28 29-30 60-65 54-59 31-33 41 105 59 34-35 71 78-81 70 70 46-51 Old and new references Old order number SCK-007 SCK-045 SCK-047 SCK-055 SCK-057 SCK-147 SCK-157 SCK-200-xxx-45 SCK-200-xxx-47 SCK-200-xxx-55 SCK-200-xxx-56 SCK-200-xxx-57 SCK-400-xxx-06 SCK-400-xxx-07 SCK-400-xxx-47 SCK-400-xxx-57 SCPSD-xxx-04-05 SCPSD-xxx-04-06 SCPSD-xxx-04-07 SCPSD-xxx-14-05 New order number SCK-145 SCK-145 SCK-145 SCK-155 SCK-155 SCK-145 SCK-155 SCK-400-xxx-45 SCK-400-xxx-45 SCK-400-..55 SCK400-xxx-56 SCK-400-..55 SCK-400-xxx-56 SCK-400-xxx-45 SCK-400-xxx-45 SCK-400-..55 SCPSD-xxx-04-17 SCPSD-xxx-04-16 SCPSD-xxx-04-17 SCPSD-xxx-14-15 Please ask about compatible products for non-listed items. Old order number SCP-xxx-x4-0x-MO SCP-xxx-x4-0x SCP-xxx-10-06 SCP-xxx-10-07 SCP-xxx-12-06 SCP-xxx-12-07 SCP-xxx-20-06 SCP-xxx-20-07 SCP-xxx-22-06 SCP-xxx-22-07 SCP-xxx-30-06 SCP-xxx-30-07 SCP-xxx-32-06 SCP-xxx-32-07 SCP-xxx-40-06 SCP-xxx-40-07 SCP-xxx-42-06 SCP-xxx-42-07 SCT-150-14-00 New order number SCP02-xxx-x4-0x SCP01-xxx-x4-0x SCP01-xxx-14-06 + SCA-1/4-M22x1.5-ED SCP01-xxx-14-07 + SCA-1/4-M22x1.5-ED SCP01-xxx-14-06 + SCA-1/4-ED-1/2-ED SCP01-xxx-14-07 + SCA-1/4-ED-1/2-ED SCP01-xxx-24-06 + SCA-1/4-M22x1.5-ED SCP01-xxx-24-07 + SCA-1/4-M22x1.5-ED SCP01-xxx-24-06 + SCA-1/4-ED-1/2-ED SCP01-xxx-24-07 + SCA-1/4-ED-1/2-ED SCP01-xxx-34-06 + SCA-1/4-M22x1.5-ED SCP01-xxx-24-07 + SCA-1/4-M22x1.5-ED SCP01-xxx-34-06 + SCA-1/4-ED-1/2-ED SCP01-xxx-24-07 + SCA-1/4-ED-1/2-ED SCP01-xxx-44-06 + SCA-1/4-M22x1.5-ED SCP01-xxx-44-07 + SCA-1/4-M22x1.5-ED SCP01-xxx-44-06 + SCA-1/4-ED-1/2-ED SCP01-xxx-44-07 + SCA-1/4-ED-1/2-ED SCT-150-14-07+SCK-400-05-45 Appendix 108 Catalogue 4083/UK Notes Appendix 109 Catalogue 4083/UK Notes Appendix 110 Catalogue 4083/UKAdobe InDesign 16.1 (Windows) Adobe PDF Library 15.0