schneider-electric.com Single phase transformers. 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6. Modicon Transformer. Catalog | October 2020
Catalog | October 2020 Modicon Transformer Single phase transformers 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6 schneider-electric.com Modicon Discover Modicon Industrial Edge control for IIoT Modicon IIoT-native edge controllers manage complex interfaces across assets and devices or directly into the cloud, with embedded safety and cybersecurity. Modicon provides performance and scalability for a wide range of industrial applications up to highperformance multi-axis machines and high-available redundant processes. Explore our offer - Modicon HVAC Controllers - Modicon PLC - Modicon Motion Controllers - Modicon PAC - Modicon I/O - Modicon Networking - Modicon Power Supply - Modicon Wiring - Modicon Safety Quick access to product information Get technical information about your product Each commercial reference presented in a catalog contains a hyperlink. Click on it to obtain the technical information of the product: Characteristics, Dimensions and drawings, Mounting and clearance, Connections and schemas, Performance curves Product image, Instruction sheet, User guide, Product certifications, End of life manual Find your catalog > With just 3 clicks, you can access the Industrial Automation and Control catalogs, in both English and French > Consult digital automation catalogs at Digi-Cat Online Select your training · Up-to-date catalogs · Embeded product selectors,360° pictures · Optimized search by commercial references > Find the right Training for your needs on our Global website > Locate the training center with the selector tool, using this link General content Modicon® Transformer Single phase transformers 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6 Selection guide for transformers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2 b Presentation............................................................................................... page 4 b Description................................................................................................. page 4 b Selection of protection...................................................................... pages 5 to 9 b References v Transformers.............................................................................................. page 10 v Separate parts.................................................................................................. page 11 v Replacement parts............................................................................................page 11 b Product reference index.......................................................................... page 12 1 Selection guide Input voltage Output voltage Modicon Transformer Single phase transformer 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6 230Vac, ±15V 24Vac 230Vac and 400Vac, ±15V 12 Vac 24Vac 115Vac 230Vac 230Vac and 400Vac, ±15V 2x24 Vac 2x115Vac Connection to world-wide line supplies United States: 120V (in phase-to-neutral) United States: 240V (in phase-to-phase) Europe: 230V (in phase-to-neutral) Single-phase (N-L1) connection Europe: 400V (in phase-to-phase) Applications Secondary winding Signalling Certifications SELV transformer (Safety Extra Low Voltage) Single winding - e marking - EAC Conformity to standards (1) - EN 61558-2-6 - EN 61558-1 - EN 62041 2-phase (L1-L2) connection Single-phase (N-L1) connection 2-phase (L1-L2) connection SELV transformer (Safety Extra Low Voltage) Single winding - C us - e marking - UL (506) - EAC - EN 61558-2-6 - UL 506 - EN 61558-1 - EN 62041 Isolation transformer - EN 61558-2-4 - EN 61558-1 - EN 62041 2-phase (L1-L2) connection Single-phase (N-L1) connection 2-phase (L1-L2) connection SELV transformer (Safety Extra Low Voltage) Isolation transformer Double winding Presence of input voltage by LED (up to 320VA) - C us, - e marking - UL (506) - EAC - EN61558-2-6 - UL506 - EN 61558-1 - EN 62041 - EN61558-2-4 - UL506 - EN 61558-1 - EN 62041 Transformer type Operating temperature Nominal power 25VA 40VA 63VA 100VA 160VA 250VA 320VA 400VA 630VA 1000VA 1600VA 2500VA Transformers 230 VAC, Single winding: ABT7ESM 40 °C ABT7ESM004B ABT7ESM006B ABT7ESM010B ABT7ESM016B ABT7ESM025B ABT7ESM032B ABT7ESM040B Transformers 230/400 VAC, Single winding: ABL6 50 °C ABL6TS02J ABL6TS04J ABL6TS06J ABL6TS10J ABL6TS16J ABL6TS25J ABL6TS02B ABL6TS04B ABL6TS06B ABL6TS10B ABL6TS16B ABL6TS25B ABL6TS40B ABL6TS63B ABL6TS100B ABL6TS160B ABL6TS250B Pages 4 (1) Consult detail on conformity to standards for each reference in the product data sheet, click on product reference to open it. Note: Phaseo Transformers shown in this document are identified as Modicon as they will undergo a future brand change. All other product documentation will reference Phaseo until the brand change occurs. ABL6TS02G ABL6TS04G ABL6TS06G ABL6TS10G ABL6TS16G ABL6TS25G ABL6TS40G ABL6TS63G ABL6TS100G ABL6TS160G ABL6TS250G 4 ABL6TS02U ABL6TS04U ABL6TS06U ABL6TS10U ABL6TS16U ABL6TS25U ABL6TS40U ABL6TS63U ABL6TS100U ABL6TS160U ABL6TS250U Transformers 230/400 VAC, Double winding: ABT7PDU 60 °C ABT7PDU004B ABT7PDU006B ABT7PDU010B ABT7PDU016B ABT7PDU025B ABT7PDU032B ABT7PDU040B ABT7PDU063B ABT7PDU100B ABT7PDU160B ABT7PDU250B ABT7PDU002G ABT7PDU004G ABT7PDU006G ABT7PDU010G ABT7PDU016G ABT7PDU025G ABT7PDU032G ABT7PDU040G ABT7PDU063G ABT7PDU100G ABT7PDU160G ABT7PDU250G 2 23 Presentation, description ABT7PDU002p...7PDU032p 4 Modicon Transformer Single phase transformers 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6 Presentation Modicon ABT7/ABL6 single-phase transformers are designed to supply control circuits in electrical equipment from a 230Vac or 400Vac supply (depending on the model) at 50 or 60 Hz. ±15V connectors at the primary ensure adaptation to the actual values of the supply networks to which they are connected. Transformers 230 V, Single winding: ABT7ESM The single-winding transformers are primarily designed for repetitive applications and offers the following as standard: b 230Vac ±15V input voltage b 24Vac output voltage b Panel mounting using 4 screws b Operating temperature of 40°C (104°F) Transformers 230/400 V, Single winding: ABL6 The single-winding transformers are designed for standard applications: b 230V/400Vac±15V input voltage b 12V, 24V, 115V or 230Vac output voltage b Panel mounting, using 4 screws (or clip-on 5 rail-mounting option available depending on the model) b Operating temperature of 50°C (122°F) b cURus certifications Transformers 230/400 V, Double winding: ABT7PDU Transformers with double winding feature an innovative design and offer high-level characteristics (depending on the model) such as: b 230V/400Vac±15V input voltage b 2x115V or 2x24Vac output voltage b Clip-on 5 rail mounting (depending on the model) or panel mounting (using 4 screws) b Series or parallel connection of secondary winding and grounding via internal jumpers b LED indicator b Operating temperature of 60°C (140°F) b cURus certification Those components are concealed behind a plastic cover making it easier to integrate the Modicon transformers in control cabinets. Protection The transformers can be protected against short-circuits by means of fuses or thermal-magnetic circuit-breakers mounted on the secondary. For operation in compliance with UL standards, short-circuit protection must be achieved using fuses (UL approved) mounted on the primary. Where the control circuit is isolated from the ground (IT system), a leakage detector will indicate any accidental ground faults. Description 1 Mounted using 4 screws or, depending on the model for ABT7PDU types, by clipping on a 35 mm (1.37 in) 5 rail 2 Screw terminals with ±15V connectors for connection of the AC input voltage 3 Clip-on marker tag or self-adhesive marker tag holder AR1SB3 1 4 LED (green) indicating presence of input voltage (depending on ABT7PDU types) 5 Access to the jumpers for selecting the secondary connection (opened using a screwdriver) 6 Windows (depending on ABT7PDU types) for viewing the connection via jumpers 2 of the: - 0 V to ground (J1 jumper) - Series connection, totally freeing up the "customer" secondary wiring capacity 3 (J3jumper) 4 - Parallel connection, totally freeing up the "customer" secondary wiring capacity (J2and J4 jumpers) 5 7 Screw terminals for connection of the AC output voltage Note: Phaseo Transformers shown in this document are identified as Modicon as they will 6 undergo a future brand change. All other product documentation will reference Phaseo until the brand change occurs. 7 Selection Modicon Transformer Single phase transformers 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6 Holding current (VA) 10 000 Selection Modicon ABT7/ABL6 transformers are characterized by the apparent nominal power they can supply continuously. However, they are also designed to supply, when necessary, significantly higher powers, such as contactor inrush peaks. Contactor inrush peaks can reach 10 to 20 times the required holding current. This leads to the transformer being oversized in relation to the continuous power it has to supply. The transformer must be sized so that the voltage drop at its terminals, caused by the inrush, remains with the permissible limits for the contactor to close properly. The two power values that need to be taken into account to determine which transformer rating to use are therefore: b The continuous power the transformer has to supply b The maximum inrush power it has to provide In practice, only the sum of the holding currents and the contactor inrush current need to be considered. For ABL6 transformers, the graph below can be used to select the appropriate rating according to these two currents. This gives a maximum voltage drop of 5% at the moment of inrush, compatible with correct operation of the entire installation. However, these transformers have been designed for continuous operation at nominal load and at an ambient temperature of 50°C (122 °F). A reduction in the ambient temperature may uprate the transformer, which, in some cases, allows a lower rating to be used. The graph below has been drawn up for ambient temperatures of 35...50°C (95...122 °F) 1000 200 100 25 VA 10 10 2500 VA 63 VA 40 VA 160 VA 100 VA 320 VA 250 VA 400 VA 1600 VA 1000 VA 630 VA 80 100 1000 10 000 Inrush current (VA) Operation at 35°C (95 °F) Operation at 50°C (122 °F) Example: A device with a total holding current of 200VA and inrush current of the contactor of 700VA can be supplied by a 630VA transformer if it is used at an ambient temperature of 50°C (122 °F). A 400VA transformer is sufficient if the ambient temperature is 35°C (95 °F). 5 Selection of protection Modicon Transformer Single phase transformers 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6 Recommended protection for the primary Protection on the primary by fuse or thermal magnetic circuit breaker Transformer Reference Power ABT7ESM004B ABT7ESM006B ABT7ESM010B ABT7ESM016B ABT7ESM025B ABT7ESM032B ABT7ESM040B 40 VA 63 VA 100 VA 160 VA 250 VA 320 VA 400 VA 230 Vac single-phase input voltage MDL fuses aM fuses TeSys UL Listed (1) GV2RT 0.3 A 0.25 A GV2RT03 0.4 A 0.5 A GV2RT03 0.5 A 0.5 A GV2RT04 1 A 1 A GV2RT05 1.25 A 2 A GV2RT06 1.5 A 2 A GV2RT06 2 A 2 A GV2RT07 Acti9 IC60 (2) 0.5 A D curve (3) 0.5 A D curve (3) 0.5 A D curve 1 A D curve 2 A D curve (3) 2 A D curve (3) 3 A D curve (3) Recommended protection for the secondary Protection on the secondary by fuses of thermal circuit breaker Transformer Reference Power ABT7ESM004B ABT7ESM006B ABT7ESM010B ABT7ESM016B ABT7ESM025B ABT7ESM032B ABT7ESM040B 40 VA 63 VA 100 VA 160 VA 250 VA 320 VA 400 VA 24 Vac secondary gG fuse (1) aM fuses 1 A 1 A 2 A 2 A 4 A 4 A 6 A 6 A 10 A 10 A 12 A 12 A 16 A 16 A TeSys Acti9 IC60 (2) GB2 (IEC/ CSA-c/US) GB2CD07 2 A C curve GB2CD08 3 A C curve GB2CD09 4 A C curve GB2CD12 6 A C curve GB2CD16 10 A C curve GB2CD20 16 A C curve GB2CD21 16 A C curve (1) For operation in compliance with UL (2) Check on our website for the exact reference. For installation in North America, please select a UL489 compliant circuit breaker (3) Protection on the secondary is necessary 6 Selection of protection (continued) Modicon Transformer Single phase transformers 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6 Recommended protection for the primary Protection on the primary by fuse or thermal magnetic circuit breaker Transformer 230 Vac single-phase Reference Power MDL aM TeSys TeSys fuses UL fuses GB2 (IEC/ GV2RT listed (1) CSA-c/US) Acti9 IC60 (2) ABT7PDU002G 25 VA 0.2 A 0.25 A ABT7PDU004B/G 40 VA 0.3 A 0.25 A GB2DB05 GV2RT03 0.5 A D curve (3) ABT7PDU006B/G 63 VA 0.5 A 0.5 A GB2DB06 GV2RT04 0.5 A D curve (3) ABT7PDU010B/G 100 VA 0.5 A 0.5 A GB2DB06 GV2RT04 1 A D curve (3) ABT7PDU016B/G 160 VA 1 A 1 A GB2DB07 GV2RT05 1 A D curve (3) ABT7PDU025B/G 250 VA 1.25 A 2 A GB2DB07 GV2RT06 2 A D curve (3) ABT7PDU032B/G 320 VA 1.5 A 2 A GB2DB07 GV2RT07 2 A D curve ABT7PDU040B/G 400 VA 2 A 2 A GB2DB09 GV2RT07 3 A D curve (3) ABT7PDU063B/G 630 VA 3 A 4 A GB2DB12 GV2RT08 6 A D curve (3) (3) ABT7PDU100B/G 1000 VA 5 A 6 A GB2DB16 GV2RT10 10 A D curve (3) (3) ABT7PDU160B/G 1600 VA 8 A 8 A GB2DB21 GV2RT14 16 A D curve (3) (3) ABT7PDU250B/G 2500 VA 12 A 25 A D curve (3) 400 Vac single-phase MDL aM TeSys fuses UL fuses GB2 (IEC/ Listed (1) CSA-c/US) 0.25 A 0.16 A 0.25 A 0.16 A 0.25 A 0.25 A 0.3 A 0.5 A GB2DB05 0.5 A 0.5 A GB2DB06 0.75 A 1 A GB2DB06 1 A 1 A GB2DB06 1.25 A 2 A (3) GB2DB07 2 A 2 A GB2DB09 (3) 3 A 4 A (3) GB2DB12 (3) 4 A 6 A (3) GB2DB14 (3) 7 A 8 A (3) GB2DB21 (3) TeSys Acti9 IC60 (2) GV2RT GV2RT03 0.5 A D curve GV2RT04 1 A D curve GV2RT05 1 A D curve GV2RT05 1 A D curve GV2RT06 2 A D curve 4 A D curve (3) 6 A D curve (3) GV2RT10 10 A D curve (3) GV2RT14 16 A D curve (3) Recommanded protection for the secondary Protection on the secondary by fuses of thermal circuit breaker Transformer 24 Vac secondary Reference Power gG fuse (1) aM fuses TeSys Acti9 IC60 (2) GB2 (IEC/ CSA-c/ US) ABT7PDU004B 40 VA 2 A 2 A GB2CD07 2 A C curve ABT7PDU006B 63 VA 2 A 2 A GB2CD08 3 A C curve ABT7PDU010B 100 VA 4 A 4 A GB2CD09 4 A C curve ABT7PDU016B 160 VA 6 A 6 A GB2CD12 6 A C curve ABT7PDU025B 250 VA 10 A 10 A GB2CD16 10 A C curve ABT7PDU032B 320 VA 12 A 12 A GB2CD20 16 A C curve ABT7PDU040B 400 VA 16 A 16 A GB2CD21 16 A C curve ABT7TDU063B 630 VA 25 A 25 A 25 A C curve ABT7TDU100B 1000 VA 40 A 40 A 40 A C curve ABT7TDU160B 1600 VA 63 A 63 A 63 A C curve ABT7TDU250B 2500 VA 100 A 100 A 48 Vac secondary gG fuse (1) aM fuses 1 A 1 A 1 A 1 A 2 A 2 A 2 A 2 A 4 A 4 A 6 A 6 A 8 A 8 A 12 A 12 A 20 A 20 A 32 A 32 A 50 A 50 A TeSys Acti9 IC60 (2) GB2 (IEC/ CSA-c/US) GB2CD06 1 A C curve GB2CD06 1 A C curve GB2CD07 2 A C curve GB2CD08 3 A C curve GB2CD10 6 A C curve GB2CD12 10 A C curve GB2CD14 10 A C curve GB2CD20 16 A C curve GB2CD22 20 A C curve 32 A C curve 50 A C curve Transformer Reference Power ABT7PDU002G ABT7PDU004G ABT7PDU006G ABT7PDU010G ABT7PDU016G ABT7PDU025G ABT7PDU032G ABT7PDU040G ABT7TDU063G ABT7TDU100G ABT7TDU160G ABT7TDU250G 25 VA 40 VA 63 VA 100 VA 160 VA 250 VA 320 VA 400 VA 630 VA 1000 VA 1600 VA 2500 VA 115 Vac secondary gG fuse (1) aM fuses 0.5 A 0.5 A 1 A 1 A 2 A 2 A 4 A 4 A 8 A 12 A 20 A 0.25 A 0.5 A 0.5 A 1 A 1 A 2 A 2 A 4 A 4 A 8 A 12 A 20 A TeSys Acti9 IC60 GB2 (IEC/ (2) CSA-c/US) GB2CD05 GB2CD05 0.5 A C curve GB2CD05 1 A C curve GB2CD06 2 A C curve GB2CD06 2 A C curve GB2CD07 3 A C curve GB2CD07 4 A C curve GB2CD09 4 A C curve GB2CD14 10 A C curve GB2CD20 16 A C curve GB2CD22 20 A C curve 230 Vac secondary gG fuse (1) aM fuses 0.5 A 0.5 A 1 A 1 A 2 A 2 A 4 A 6 A 10 A 0.16 A 0.25 A 0.25 A 0.5 A 0.5 A 1 A 1 A 2 A 2 A 4 A 6 A 10 A (1) For operation in compliance with UL. (2) Check on our website for the exact reference. For installation in North America. please select a UL489 compliant circuit breaker. (3) Protection on the secondary is necessary. TeSys Acti9 IC60 (2) GB2 (IEC/ CSA-c/US) GB2CD06 0.5 A C curve GB2CD07 1 A C curve GB2CD07 1 A C curve GB2CD08 2 A C curve GB2CD08 2 A C curve GB2CD07 2 A C curve GB2CD09 4 A C curve GB2CD12 6 A C curve GB2CD16 10 A C curve 7 Selection of protection (continued) Modicon Transformer Single phase transformers 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6 Recommended protection for the primary Protection on the primary by fuse or thermal magnetic circuit breaker Transformer 230 Vac single-phase input voltage Reference Power MDL fuses aM TeSys TeSys UL listed (1) fuses GB2 (IEC/ GV2RT CSA-c/ US) Acti9 IC60 (2) ABL6TS02J 25 VA 0.18 A 0.16 A ABL6TS04J 40 VA 0.25 A 0.25 A GB2DB05 GV2RT03 0.5 A D curve (3) ABL6TS06J 63 VA 0.37 A 0.5 A GB2DB05 GV2RT03 0.5 A D curve (3) ABL6TS10J 100 VA 0.5 A 0.5 A GB2DB06 GV2RT04 1 A D curve (3) ABL6TS16J 160 VA 1 A 1 A GB2DB07 GV2RT05 2 A D curve (3) ABL6TS25J 250 VA 1.25 A 2 A GB2DB07 GV2RT06 2 A D curve (3) 400 Vac single-phase input voltage MDL fuses aM TeSys TeSys UL Listed (1) fuses GB2 (IEC/ GV2RT CSA-c/US) Acti9 IC60 (2) 0.25 A 0.25 A 0.25 A 0.3 A 0.5 A 0.75 A 0.16 A 0.16 A 0.25 A 0.5 A 0.5 A 1 A GB2DB05 GV2RT03 GB2DB06 GV2RT04 GB2DB06 GV2RT05 0.5 A D curve 1 A D curve 1 A D curve Recommanded protection for the secondary Protection on the secondary by fuses of thermal circuit breaker Transformer 12 Vac secondary Reference Power gG fuse (1) aM fuses TeSys Acti9 IC60 (2) GB2 (IEC/ CSA-c/US) ABL6TS02J 25 VA 2 A 2 A GB2CD07 2 A C curve ABL6TS04J 40 VA 4 A 4 A GB2CD08 3 A C curve ABL6TS06J 63 VA 6 A 6 A GB2CD10 6 A C curve ABL6TS10J 100 VA 8 A 8 A GB2CD14 10 A C curve ABL6TS16J 160 VA 12 A 12 A GB2CD20 16 A C curve ABL6TS25J 250 VA 20 A 20 A GB2CD22 20 A C curve Recommended protection for the primary Protection on the primary by fuse or thermal magnetic circuit breaker Transformer 230 Vac single-phase input voltage Reference Power MDL fuses aM TeSys TeSys UL listed (1) fuses GB2 (IEC/ GV2RT CSA-c/ US) Acti9 IC60 (2) ABL6TS02B 25 VA 0.18 A 0.16 A ABL6TS04B 40 VA 0.25 A 0.25 A GB2DB05 GV2RT03 0.5 A D curve (3) ABL6TS06B 63 VA 0.37 A 0.5 A GB2DB05 GV2RT03 0.5 A D curve (3) ABL6TS10B 100 VA 0.5 A 0.5 A GB2DB05 GV2RT04 1 A D curve (3) ABL6TS16B 160 VA 1 A 1 A GB2DB06 GV2RT05 2 A D curve (3) ABL6TS25B 250 VA 1.25 A 2 A GB2DB07 GV2RT06 2 A D curve (3) ABL6TS40B 400 VA 2 A 2 A GB2DB09 GV2RT07 3 A D curve (3) ABL6TS63B 630 VA 3 A 4 A GB2DB12 GV2RT08 6 A D curve (3) ABL6TS100B 1000 VA 5 A 6 A GB2DB16 GV2RT10 10 A D curve (3) ABL6TS160B 1600 VA 8 A 8 A GB2DB20 GV2RT14 16 A D curve (3) ABL6TS250B 2500 VA 12 A GB2DB22 GV2RT16 20 A D curve (3) 400 Vac single-phase input voltage MDL fuses aM TeSys TeSys UL Listed (1) fuses GB2 (IEC/ GV2RT CSA-c/US) Acti9 IC60 (2) 0.25 A 0.25 A 0.25 A 0.3 A 0.5 A 0.75 A 1.5 A 2.5 A 3.5 A 5 A 7.5 A 0.16 A 0.16 A 0.25 A 0.5 A 0.5 A 1 A 1 A 2 A 4 A 4 A 8 A (3) GB2DB05 GV2RT03 GB2DB06 GV2RT04 GB2DB06 GV2RT05 GB2DB07 GV2RT06 GB2DB09 GV2RT07 GB2DB10 GV2RT08 GB2DB14 GV2RT10 GB2DB20 GV2RT14 0.5 A D curve 1 A D curve 1 A D curve 2 A D curve 3 A D curve 6 A D curve 10 A D curve 10 A D curve Recommanded protection for the secondary Protection on the secondary by fuses of thermal circuit breaker Transformer 24 Vac secondary Reference Power gG fuse (1) aM fuses TeSys Acti9 IC60 GB2 (IEC/ (2) CSA-c/US) ABL6TS02B 25 VA 1 A 1 A GB2CD06 1 A C curve ABL6TS04B 40 VA 1 A 1 A GB2CD07 2 A C curve ABL6TS06B 63 VA 2 A 2 A GB2CD08 3 A C curve ABL6TS10B 100 VA 4 A 4 A GB2CD09 4 A C curve ABL6TS16B 160 VA 6 A 6 A GB2CD12 6 A C curve ABL6TS25B 250 VA 10 A 10 A GB2CD16 10 A C curve ABL6TS40B 400 VA 16 A 16 A GB2CD21 16 A C curve ABL6TS63B 630 VA 25 A 25 A 25 A C curve ABL6TS100B 1000 VA 40 A 40 A 40 A C curve ABL6TS160B 1600 VA 63 A 63 A 63 A C curve ABL6TS250B 2500 VA 100 A 100 A (1) For operation in compliance with UL (2)Check on our website for the exact reference. For installation in North America, please select a UL489 compliant circuit breaker (3) Protection on the secondary is necessary 8 Selection of protection (continued) Modicon Transformer Single phase transformers 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6 Recommended protection for the primary Protection on the primary by fuse or thermal magnetic circuit breaker Transformer 230 Vac single-phase input voltage Reference Power MDL fuses aM TeSys GB2 TeSys GV2RT Acti9 IC60 (2) UL listed fuses (IEC/CSA-c/ (1) US) ABL6TS02G 25 VA 0.18 A 0.16 A ABL6TS04G 40 VA 0.25 A 0.25 A GB2DB05 GV2RT03 0.5 A D curve (3) ABL6TS06G 63 VA 0.37 A 0.5 A GB2DB06 GV2RT03 0.5 A D curve (3) ABL6TS10G 100 VA 0.5 A 0.5 A GB2DB06 GV2RT04 1 A D curve (3) ABL6TS16G 160 VA 1 A 1 A GB2DB07 GV2RT05 1 A D curve (3) ABL6TS25G 250 VA 1.25 A 2 A GB2DB07 GV2RT06 2 A D curve (3) ABL6TS40G 400 VA 2 A 2 A GB2DB09 GV2RT07 4 A D curve (3) ABL6TS63G 630 VA 3 A 4 A GB2DB12 GV2RT08 6 A D curve (3) ABL6TS100G 1000 VA 5 A 6 A GB2DB16 GV2RT10 10 A D curve (3) ABL6TS160G 1600 VA 8 A 8 A GB2DB16 GV2RT14 10 A D curve (3) ABL6TS250G 2500 VA 25A(3) 400 Vac single-phase input voltage MDL fuses aM TeSys GB2 TeSys GV2RT Acti9 IC60 (2) UL Listed(1) fuses (IEC/CSA-c/ US) 0.25 A 0.16 A 0.25 A 0.16 A 0.25 A 0.25 A 0.3 A 0.5 A GB2DB05 GV2RT03 0.5 A D curve 0.5 A 0.5 A GB2DB06 GV2RT04 1 A D curve 0.75 A 1 A GB2DB06 GV2RT05 1 A D curve 1.5 A 2 A (3) GB2DB07 GV2RT06 2 A D curve 2.5 A 4 A (3) GB2DB08 GV2RT07 3 A D curve 3.5 A 4 A GB2DB10 GV2RT08 6 A D curve 5 A 4 A GB2DB12 GV2RT10 6 A D curve 10 A (3) GB2DB22 GV2RT16 (3) Recommanded protection for the secondary Protection on the secondary by fuses of thermal circuit breaker Transformer 115 Vac secondary Reference Power gG fuse (1) aM fuses TeSys GB2 (IEC/ CSA-c/US) ABL6TS02G 25 VA 0.25 A ABL6TS04G 40 VA 0.5 A 0.5 A ABL6TS06G 63 VA 0.5 A 0.5 A GB2CD05 ABL6TS10G 100 VA 1 A 1 A GB2CD06 ABL6TS16G 160 VA 1 A 1 A GB2CD07 ABL6TS25G 250 VA 2 A 2 A GB2CD07 ABL6TS40G 400 VA 4 A 4 A GB2CD09 ABL6TS63G 630 VA 6 A 6 A GB2CD12 ABL6TS100G 1000 VA 8 A 8 A GB2CD16 ABL6TS160G 1600 VA 12 A 12 A GB2CD21 ABL6TS250G 2500 VA 20 A 20 A GB2CD22 Acti9 IC60 (2) 0.5 A C curve 1 A C curve 2 A C curve 2 A C curve 4 A C curve 6 A C curve 10 A C curve 16 A C curve 20 A C curve Recommended protection for the primary Protection on the primary by fuse or thermal magnetic circuit breaker Transformer 230 Vac single-phase input voltage Reference Power MDL fuses aM TeSys GB2 TeSys GV2RT Acti9 IC60 (2) UL listed fuses (IEC/CSA-c/ (1) US) ABL6TS02U 25 VA 0.18 A 0.16 A ABL6TS04U 40 VA 0.25 A 0.25 A GB2DB05 GV2RT03 0.5 A D curve (3) ABL6TS06U 63 VA 0.37 A 0.5 A GB2DB05 GV2RT03 0.5 A D curve (3) ABL6TS10U 100 VA 0.5 A 0.5 A GB2DB05 GV2RT04 1 A D curve (3) ABL6TS16U 160 VA 1 A 1 A GB2DB06 GV2RT05 2 A D curve (3) ABL6TS25U 250 VA 1.25 A 2 A GB2DB07 GV2RT06 2 A D curve (3) ABL6TS40U 400 VA 2 A 2 A GB2DB09 GV2RT07 3 A D curve (3) ABL6TS63U 630 VA 3 A 4 A GB2DB14 GV2RT10 (3) 10 A D curve (3) ABL6TS100U 1000 VA 5 A 6 A GB2DB20 GV2RT14 (3) 10 A D curve (3) ABL6TS160U 1600 VA 8 A 8 A GB2DB20 GV2RT14 16 A D curve (3) ABL6TS250U 2500 VA 16 A (3) 400 Vac single-phase input voltage MDL fuses aM TeSys GB2 TeSys GV2RT Acti9 IC60 (2) UL Listed(1) fuses (IEC/CSA-c/ US) 0.25 A 0.16 A 0.25 A 0.16 A 0.25 A 0.25 A 0.3 A 0.5 A GB2DB05 GV2RT03 0.5 A D curve 0.5 A 0.5 A GB2DB06 GV2RT04 1 A D curve 0.75 A 1 A GB2DB06 GV2RT05 1 A D curve 1.5 A 2 A (3) GB2DB07 GV2RT06 2 A D curve 2.5 A 4 A (3) GB2DB10 GV2RT08(3) 4 A D curve 5 A (3) 4 A GB2DB12 GV2RT10 (3) 6 A D curve 5 A (3) 4 A GB2DB14 GV2RT10 6 A D curve 10 A (3) GB2DB22 GV2RT16 (3) 16 A D curve Recommanded protection for the secondary Protection on the secondary by fuses of thermal circuit breaker Transformer 230 Vac secondary Reference Power gG fuse aM TeSys Acti9 IC60 (2) (1) fuses GB2 (IEC/ CSA-c/US) ABL6TS02U 25 VA 0.16 A ABL6TS04U 40 VA 0.16 A ABL6TS06U 63 VA 0.25 A ABL6TS10U 100 VA 0.5 A 0.5 A GB2CD05 0.5 A C curve ABL6TS16U 160 VA 0.5 A 0.5 A GB2CD06 1 A C curve ABL6TS25U 250 VA 1 A 1 A GB2CD06 1 A C curve ABL6TS40U 400 VA 2 A 2 A GB2CD07 2 A C curve ABL6TS63U 630 VA 2 A 2 A GB2CD08 3 A C curve ABL6TS100U 1000 VA 4 A 4 A GB2CD09 4 A C curve ABL6TS160U 1600 VA 6 A 6 A GB2CD14 6 A C curve ABL6TS250U 2500 VA 10 A 10 A GB2CD16 10 A C curve (1) For operation in compliance with UL (2) Check on our website for the exact reference. For installation in North America, please select a UL489 compliant circuit breaker. (3) Protection on the secondary is necessary 9 References ABT7ESM0ppB ABL6TSppp Modicon Transformer Single phase transformers 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6 Transformers with single phase (N-L1) or phase-to-phase (L1-L2) connection Input voltage Secondary Type Voltage Nominal power Reference Weight kg/lb Transformers 230 VAC, Single winding 230 Vac single phase, (N-L1) or phase to phase (L1-L2) connection ± 15 V Single winding 24V 40VA 63VA 100VA 160VA 250VA 320VA 400VA ABT7ESM004B ABT7ESM006B ABT7ESM010B ABT7ESM016B ABT7ESM025B ABT7ESM032B ABT7ESM040B 1.020/2.249 1.140/2.513 1.900/4.189 2.720/5.997 3.540/7.804 4.080/8.995 5.100/11.244 Transformers 230/400 VAC, Single winding 230 Vac single phase, (N-L1), Single winding 400 Vac phase to phase (L1-L2) ± 15 V 12V 25VA 40VA 63VA 100VA 160VA 250VA ABL6TS02J ABL6TS04J ABL6TS06J ABL6TS10J ABL6TS16J ABL6TS25J 0.700/1.543 1.200/2.646 1.600/3.527 2.100/4.630 3.200/7.055 4.400/9.700 24V 25VA 40VA 63VA 100VA 160VA 250VA 400VA 630VA 1000VA 1600VA 2500VA ABL6TS02B ABL6TS04B ABL6TS06B ABL6TS10B ABL6TS16B ABL6TS25B ABL6TS40B ABL6TS63B ABL6TS100B ABL6TS160B ABL6TS250B 0.700/1.543 1.200/2.646 1.600/3.527 2.100/4.630 3.200/7.055 4.400/9.700 6.500/14.330 9.800/21.605 14.300/31.526 19.400/42.770 27.400/60.407 115V 25VA 40VA 63VA 100VA 160VA 250VA 400VA 630VA 1000VA 1600VA 2500VA ABL6TS02G ABL6TS04G ABL6TS06G ABL6TS10G ABL6TS16G ABL6TS25G ABL6TS40G ABL6TS63G ABL6TS100G ABL6TS160G ABL6TS250G 0.700/1.543 1.200/2.646 1.600/3.527 2.100/4.630 3.200/7.055 4.400/9.700 6.500/14.330 9.800/21.605 14.300/31.526 19.400/42.770 27.400/60.407 230V 25VA 40VA 63VA 100VA 160VA 250VA 400VA 630VA 1000VA 1600VA 2500VA ABL6TS02U ABL6TS04U ABL6TS06U ABL6TS10U ABL6TS16U ABL6TS25U ABL6TS40U ABL6TS63U ABL6TS100U ABL6TS160U ABL6TS250U 0.700/1.543 1.200/2.646 1.600/3.527 2.100/4.630 3.200/7.055 4.400/9.700 6.500/14.330 9.800/21.605 14.300/31.526 19.400/42.770 27.400/60.407 10 References (continued) Modicon Transformer Single phase transformers 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6 ABT7PDU002p...032p ABT7PDU040p...250p ABL6AM0p AR1SB3 Transformers with single phase (N-L1) or phase-to-phase (L1-L2) connection Input voltage Secondary Type Voltage Nominal power Reference Weight kg/lb Transformers 230/400 V, Double winding With cover, connected by internal jumpers with LED indicators 230 Vac single phase, (N-L1), Double winding 2 x 24V 400 Vac phase to phase (L1-L2) ± 15 V 40VA 63VA 100VA 160VA 250VA 320VA ABT7PDU004B ABT7PDU006B ABT7PDU010B ABT7PDU016B ABT7PDU025B ABT7PDU032B 1.400/3.086 1.940/4.277 2.860/6.305 4.400/9.700 5.600/12.346 7.100/15.653 2 x 115V 25VA 40VA 63VA 100VA 160VA 250VA 320VA ABT7PDU002G ABT7PDU004G ABT7PDU006G ABT7PDU010G ABT7PDU016G ABT7PDU025G ABT7PDU032G 1.100/2.425 1.400/3.086 1.940/4.277 2.860/6.305 4.400/9.700 5.600/12.346 7.100/15.653 Without cover, connected by external jumpers 230 Vac single phase, (N-L1), Double winding 2 x 24V 400 Vac phase to phase (L1-L2) ± 15 V 400VA 630VA 1000VA 1600VA 2500VA ABT7PDU040B ABT7PDU063B ABT7PDU100B ABT7PDU160B ABT7PDU250B 7.400/16.314 7.900/17.418 14.000/30.865 20.000/44.092 28.000/61.729 2 x 115V 400VA 630VA 1000VA 1600VA 2500VA ABT7PDU040G ABT7PDU063G ABT7PDU100G ABT7PDU160G ABT7PDU250G 7.400/16.314 7.900/17.418 14.000/30.865 20.000/44.092 28.000/61.729 Separate parts for ABT7 and ABL6 Designation Use on transformers Plates for mounting on5 rail ABL6TS02J, ABL6TS02B, ABL6TS02G, ABL6TS02U Order in multiples of 5 Unit reference ABL6AM00 Weight kg/lb 0.045/0.099 ABT7ESM004B, ABT7ESM006B, 5 ABL6TS04J, ABL6TS04B, ABL6TS04G, ABL6TS04U ABL6AM01 0.050/0.110 ABL6TS06J, ABL6TS06B, 5 ABL6TS06G, ABL6TS06U ABL6AM02 0.055/0.121 ABT7ESM010B,ABL6TS10J, 5 ABL6TS10B, ABL6TS10G, ABL6TS10U ABL6AM03 0.065/0.143 ABT7ESM016B 5 ABL6AM04 0.085/0.187 Self-adhesive marker tag 50 holder 20 x 10 mm (0.78 x 0.39 in) Replacement parts for ABT7 and ABL6 Designation Use on Pack of 10 jumpers ABT7PDU double-winding transformer AR1SB3 0.001/0.002 Reference ABT7JMP01 Weight kg/lb 0.010/0.022 11 Index Modicon Transformer Single phase transformers 230 to 400 Vac, 25 to 2500 VA Modicon ABT7, ABL6 A ABT7PDU032B 11 ABL6AM00 11 ABT7PDU032G 11 ABL6AM01 11 ABT7PDU040B 11 ABL6AM02 11 ABT7PDU040G 11 ABL6AM03 11 ABT7PDU063B 11 ABL6AM04 11 ABT7PDU063G 11 ABL6TS02B 10 ABT7PDU100B 11 ABL6TS02G 10 ABT7PDU100G 11 ABL6TS02J 10 ABT7PDU160B 11 ABL6TS02U 10 ABT7PDU160G 11 ABL6TS04B 10 ABT7PDU250B 11 ABL6TS04G 10 ABT7PDU250G 11 ABL6TS04J 10 ABT7TDU063B 7 ABL6TS04U 10 ABT7TDU063G 7 ABL6TS06B 10 ABT7TDU100B 7 ABL6TS06G 10 ABT7TDU100G 7 ABL6TS06J 10 ABT7TDU160B 7 ABL6TS06U 10 ABT7TDU160G 7 ABL6TS100B 10 ABT7TDU250B 7 ABL6TS100G 10 ABT7TDU250G 7 ABL6TS100U 10 AR1SB3 11 ABL6TS10B 10 ABL6TS10G 10 ABL6TS10J 10 ABL6TS10U 10 ABL6TS160B 10 ABL6TS160G 10 ABL6TS160U 10 ABL6TS16B 10 ABL6TS16G 10 ABL6TS16J 10 ABL6TS16U 10 ABL6TS250B 10 ABL6TS250G 10 ABL6TS250U 10 ABL6TS25B 10 ABL6TS25G 10 ABL6TS25J 10 ABL6TS25U 10 ABL6TS40B 10 ABL6TS40G 10 ABL6TS40U 10 ABL6TS63B 10 ABL6TS63G 10 ABL6TS63U 10 ABT7ESM004B 10 ABT7ESM006B 10 ABT7ESM010B 10 ABT7ESM016B 10 ABT7ESM025B 10 ABT7ESM032B 10 ABT7ESM040B 10 ABT7JMP01 11 ABT7PDU002G 11 ABT7PDU004B 11 ABT7PDU004G 11 ABT7PDU006B 11 ABT7PDU006G 11 ABT7PDU010B 11 ABT7PDU010G 11 ABT7PDU016B 11 ABT7PDU016G 11 ABT7PDU025B 11 ABT7PDU025G 11 12 Learn more about our products at www.schneider-electric.com The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Design: Schneider Electric Photos: Schneider Electric Schneider Electric Industries SAS Head Office 35, rue Joseph Monier - CS 30323 F-92500 Rueil-Malmaison Cedex France DIA3ED2170403EN October 2020 - V3.0Adobe PDF Library 15.0