MXZ-3C30NA2 MULTI-ZONE INVERTER HEAT-PUMP SYSTEM

1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Unit: inch 13 MXZ-3C24NA MXZ-3C30NA Unit: inch (mm) Lock nut Conduit plates

MXZ-3C30NA2

2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. ... (For data on specific indoor units, see the MXZ-C Technical and Service Manual.) Cooling*.

PDF preview unavailable. Download the PDF instead.

mitsubishi mxz-3c30na2-u1 article 1464020679927 en ss
Job Name: System Reference:

MXZ-3C30NA2
MULTI-ZONE INVERTER HEAT-PUMP SYSTEM

Date:

FEATURES · Variable speed INVERTER-driven compressor · Optional base pan heater · Quiet outdoor unit operation as low as 56 dB(A) · High pressure protection · Compressor thermal protection · Compressor overcurrent detection · Fan motor overheating/voltage protection

Specifications are subject to change without notice.

© 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

SPECIFICATIONS: MXZ-3C30NA2

Cooling* (Non-ducted / Ducted)
Heating at 47°F* (Non-ducted / Ducted)
Heating at 17°F* (Non-ducted/Ducted) Connectable Capacity
Electrical Requirements
Voltage Compressor Fan Motor (ECM) Sound Pressure Level
External Dimensions (H x W x D) Net Weight External Finish Refrigerant Pipe Size O.D. Max. Refrigerant Line Length Max. Piping Length for Each Indoor Unit Max. Refrigerant Pipe Height Difference Connection Method Refrigerant

Rated Capacity Capacity Range Rated Total Input Rated Capacity Capacity Range Rated Total Input Rated Capacity Rated Total Input
Power Supply Recommended Fuse/Breaker Size MCA Indoor - Outdoor S1-S2 Indoor - Outdoor S2-S3
Cooling Heating
Liquid (High Pressure) Gas (Low Pressure)
If IDU is Above ODU If IDU is Below ODU

(For data on specific indoor units, see the MXZ-C Technical and Service Manual.)

Btu/h Btu/h
W Btu/h Btu/h
W Btu/h
W Btu/h Voltage, Phase, Hertz
A A V V
F.L.A. dB(A) dB(A)
In mm Lbs / kg
In / mm In / mm Ft / m Ft / m Ft / m Ft / m

28,400 / 27,400 9,500 - 28,400 / 9,500 - 27,400
2,680 / 2,860 28,600 / 27,600 15,500 - 36,000 / 15,500 - 35,000
2,150 / 2,220 16,000 / 15,100
2,120 / 2,140 12,000 - 36,000 208 / 230V, 1-Phase, 60 Hz
25 22.1 AC 208 / 230 DC ±24 INVERTER-driven Scroll Hermetic 2.43 52 56 31-11/32 x 37-13/32 x 13 (796 x 950 x 330) 137 (62) Munsell No. 3Y 7.8/11 1/4 (12.7) A: 1/2 (6.35) ; B,C: 3/8 (9.52) 230 (70) 82 (25) 49 (15) 49 (15) Flared/Flared R410A

* Rating Conditions per AHRI Standard: Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WB

Heating at 47ºF | Indoor: 70º F (21º C) DB Heating at 47ºF | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB

Heating at 17º F | Indoor: 70º F (21º C) DB Heating at 17º F | Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB

OPERATING RANGE:

ENERGY EFFICIENCIES:

Cooling Heating

Outdoor 14 to 115° F (-10 to 46° C) DB 5 to 65° F (-15 to 18° C) WB

Indoor Unit Type
Non-ducted (09+09+12)
Ducted and Non-ducted
Ducted (09+09+12)

SEER 19.0 17.6 16.2

EER 10.6 10.1 9.6

HSPF 10.6 10.1 9.6

COP @ 47°F 3.90

COP @ 17°F 2.77

3.77

2.78

3.64

2.78

NOTES: For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity can exceed rated, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time.

Specifications are subject to change without notice.

© 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

OUTDOOR UNIT ACCESSORIES: MXZ-3C30NA2

Air Outlet Guide

Air Outlet Guide (1 Piece)

Refrigeration Ball Valve - 1/2"

Ball Valve

Refrigeration Ball Valve - 1/4" Refrigeration Ball Valve - 3/8"

Refrigeration Ball Valve - 5/8"

Distribution pipe for Branch Box

M-NET Converter

Drain Socket

Drain Socket

Hail Guards

Hail Guard

Mounting Pad

Condensing Unit Mounting Pad: 16" x 36" x 3" Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic

Optional Defrost Heater

Base Heater

Adaptor: 1/2" x 3/8"

Port Adapter

Adaptor: 1/2" x 5/8" Adaptor: 3/8" x 1/2"

Adaptor: 3/8" x 5/8"

Power Supplies and Auxiliary Components M-Net Control Wire, 1,000' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated)

Power Supplies And Auxiliary Components M-Net Control Wire, 250' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated)

18" Single Fan Stand

24" Single Fan Stand

Stand

Condenser Wall Bracket

Condenser Wall Bracket -Stainless Steel Finish

Outdoor Unit Stand -- 12" High

  PAC-SH96SG-E   BV12FFSI2   BV14FFSI2   BV38FFSI2   BV58FFSI2   PAC-IF01MNT-E   PAC-SG60DS-E   HG-A9   ULTRILITE1   DSD-400P   PAC-646BH-E   MAC-A455JP-E   MAC-A456JP-E   MAC-A454JP-E   PAC-SG76RJ-E   CW162S-1000   CW162S-250   QSMS1801M   QSMS2401M   QSWB2000M-1   QSWBSS   QSMS1201M

Specifications are subject to change without notice.

© 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

MXZ-3C24NA MXZ-3C30NA

OUTDOOR UNIT DIMENSIONS: MXZ-3C30NA2

UnitU: ninit:cihnc(hmm)

Conduit plates Conduit connector
Lock nut

OBH702A FORM# M_SUBMITTAL_MXZ-3C30NA2_en - 202103
Specifications are subject to change without notice.

1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com
13
© 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.


Adobe PDF Library 15.0 Adobe InDesign 16.1 (Windows)