Harmonized global standards and the increasing adoption of MEPS around the world are good news for all of us. However, it is important to remem-.150 pages
CATALOG | FEBRUARY 2020 Low voltage Process performance motors 400 V 50 Hz, 460V 60 Hz With expertise, and a comprehensive portfolio of products and life-cycle services, we help value-minded industrial customers improve their energy efficiency and productivity. 2 9AKK105944 EN 02-2020 | ABB Motors and Generators Low voltage Process performance motors Sizes 63 to 450, 0.09 to 1000 kW 4 General information 4 International motor efficiency standards and regulations 7 Mounting arrangements 8 Cooling 9 Degrees of protection: IP code/IK code 10 Insulation 11 Voltage and frequency 12 Surface treatment 13 Variable speed drives with Process performance motors 18 Cast iron motors 18 Ordering information 19 Rating plates 20 Technical data 56 Variant codes 63 Mechanical design 86 Dimension drawings 91 Accessories 99 Cast iron motors in brief 102 Motor construction 104 Aluminum motors 104 Ordering information 105 Rating plates 106 Technical data 123 Variant codes 128 Mechanical design 142 Dimension drawings 145 Accessories 146 Aluminum motors in brief 148 Total product offering 149 ABB's portfolio of drives ABB Motors and Generators | 9AKK105944 EN 02-2020 3 International motor efficiency standards and regulations Energy Efficiency Regulations, EE Regulations 2016, Canada DOE 10 CFR Part 431 (Integral Horsepower Motor Rule), US NOM-016-ENER-2016, Mexico PRTE-145, Equador RTEE, Peru Chile Portaria interministerial No 553, Brazil IRAM 62405, Argentina BIS IS 12615, India Singapore Indonesia SASO/IEC 60034-30, Saudi-Arabia Regulation EC No 640/2009 MKE-2015-28, South-Korea JIS 4213, Japan GB18613-2012, China CNS 14400, Taiwan Decree No. 21/2011/ND-CP, Vietnam Greenhouse and Energy Minimum Standards Act, Australia Energy efficiency and Conservation Authority New Zealand Since the validation of IEC 60034-30:2008 and its refined version IEC 60034-30-1:2014, a worldwide energy efficiency classification system has existed for low voltage three-phase asynchronous motors. These international standards have been created to enable and increase the level of harmonization in efficiency regulations around the world and to also cover motors for explosive atmospheres. IEC 60034-30-1:2014 defines International Efficiency (IE) classes for single speed, three-phase, 50 Hz and 60 Hz induction motors. The efficiency levels defined in IEC 60034-30-1 are based on the test method specified in IEC 60034-2-1:2014. Both standards are part of an effort to unify motor testing procedures with CSA390-10 and IEEE 112 standards as well as efficiency and product labeling (IE) requirements to enable motor purchasers worldwide to easily recognize premium efficiency products. To promote transparency in the market, IEC 60034-30-1 states that both the efficiency class and efficiency value must be shown on the motor rating plate and in product documentation. The documentation must clearly indicate the efficiency testing method used as different methods can produce differing results. Minimum energy performance standards While the IEC as an international standardization organization sets guidelines for motor testing and efficiency classes, the organization does not regulate efficiency levels in countries. The biggest drivers for mandatory Minimum Energy Perfor- mance Standard (MEPS) levels for electric motors are global climate change, government targets to curb CO2 emissions and rising electricity demand, especially in developing countries. The whole value chain, from manufacturer up to end user, must be aware of the legislation in order to meet local requirements, to save energy and reduce the carbon footprint. Harmonized global standards and the increasing adoption of MEPS around the world are good news for all of us. However, it is important to remember that harmonization is an ongoing process. Even though MEPS are already in effect in several regions and countries, they are evolving and differ in terms of scope and requirements. At the same time, more countries are planning to adopt their own MEPS regulations. A view of existing and coming MEPS regulations in the world can be seen on the World map above. To get the latest information please visit www.abb. com/motors&generators/energyefficiency. 4 9AKK105944 EN 02-2020 | ABB Motors and Generators 01 IE Classes - 4-pole motors. IEC 60034-30-1:2014 This standard defines four International Efficiency (IE) classes for single speed electric motors that are rated according to IEC 60034-1 or IEC 60079-0 (explosive atmospheres) and designed for operation on sinusoidal voltage. IE4 = Super premium efficiency IE3 = Premium efficiency, identical to the table in 10CFR431 (`NEMA Premium') in the USA and CSA C390-10:2015 for 60 Hz IE2 = High efficiency IE1 = Standard efficiency IEC 60034-30-1 covers the power range from 0.12 kW up to 1000 kW. Most of the different technical constructions of electric motors are covered as long as they are rated for direct on-line operation. The coverage of the standard includes: Single speed electric motors (single and threephase), 50 and 60 Hz 2, 4, 6 and 8 poles Rated output PN from 0.12 kW to 1000 kW Rated voltage UN above 50 V up to 1 kV Motors capable of continuous operation at their rated power with a temperature rise within the specified insulation temperature class Motors, marked with any ambient temperature within the range of -20 °C to +60 °C Motors, marked with an altitude up to 4000 m above sea level By comparing IEC 60034-30-1 to CSA C39010:2015 and "10CFR431 Subpart B Electric motors", it can be seen that the efficiency limits and tables are well aligned and their major difference is in the scope of the output power where CSA and 10CFR431 have a maximum power of 500 hp. There are also some minor differences in the scope of excluded motors. Note: CFR is Code of Federal Regulations. The following motors are excluded from IEC 60034-30-1: Single-speed motors with 10 or more poles or multi-speed motors Motors completely integrated into a machine (for example pump, fan or compressor) that cannot be tested separately from the machine Brake motors, when the brake cannot be dismantled or separately fed 100 90 Efficiency % 80 IE4 IE3 70 IE2 IE1 60 50 0.12 0.37 0.75 1.5 3 7.5 15 37 Output kW 90 160 400 1000 __ 01 ABB and efficiency standards ABB determines efficiency values according to IEC 60034-2-1 using the low uncertainty method (i.e. summaration of losses), with additional load losses determined by the method of residual loss. It is good to mention and emphasize that the IEC 60034-2-1 test method, which is known as an indirect method, is technically equivalent to the test methods in the standards CSA 390-10 and IEEE 112 Method B leading to the equivalent losses and thus efficiency values. Both test methods can be used by ABB and shall be used for both Canada and the US where IEC 60034-2-1 is not recognized yet. As the world market leader, ABB offers the largest range of LV motors available. It has long advocated the need for efficiency in motors, and high efficiency products have formed the core of its portfolio for many years. The core of ABB's Process performance range is based on a full range of IE2 and IE3 motors - with many available from stock. We also supply IE4 motors for additional energy savings. ABB Motors and Generators | 9AKK105944 EN 02-2020 5 Nominal efficiency limits defined in IEC 60034-30-1:2014 (reference values at 50 Hz, based on test methods specified in IEC 600342-1:2014). Output kW 0.12 0.18 0.20 0.25 0.37 0.40 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250 315 355 400 450 5001000 IE1 Standard efficiency IE2 High efficiency IE3 Premium efficiency IE4 Super Premium efficiency 2 pole 45.0 52.8 54.6 58.2 63.9 64.9 69.0 72.1 75.0 77.2 79.7 81.5 83.1 84.7 86.0 87.6 88.7 89.3 89.9 90.7 91.2 91.7 92.1 92.7 93.0 93.3 93.5 93.8 94.0 94.0 94.0 94.0 94.0 94.0 94.0 4 pole 50.0 57.0 58.5 61.5 66.0 66.8 70.0 72.1 75.0 77.2 79.7 81.5 83.1 84.7 86.0 87.6 88.7 89.3 89.9 90.7 91.2 91.7 92.1 92.7 93.0 93.3 93.5 93.8 94.0 94.0 94.0 94.0 94.0 94.0 94.0 6 pole 38.3 45.5 47.6 52.1 59.7 61.1 65.8 70.0 72.9 75.2 77.7 79.7 81.4 93.1 84.7 86.4 87.7 88.6 89.2 90.2 90.8 91.4 91.9 92.6 92.9 93.3 93.5 93.8 94.0 94.0 94.0 94.0 94.0 94.0 94.0 8 pole 31.0 38.0 39.7 43.4 49.7 50.9 56.1 61.2 66.5 70.2 74.2 77.0 79.2 81.4 83.1 85.0 86.2 86.9 87.4 88.3 88.8 89.2 89.7 90.3 90.7 91.1 91.5 91.9 92.5 92.5 92.5 92.5 92.5 92.5 92.5 2 pole 4 pole 53.6 59.1 60.4 64.7 61.9 65.9 64.8 68.5 69.5 72.7 70.4 73.5 74.1 77.1 77.4 79.6 79.6 81.4 81.3 82.8 83.2 84.3 84.6 85.5 85.8 86.6 87.0 87.7 88.1 88.7 89.4 89.8 90.3 90.6 90.9 91.2 91.3 91.6 92.0 92.3 92.5 92.7 92.9 93.1 93.2 93.5 93.8 94.0 94.1 94.2 94.3 94.5 94.6 94.7 94.8 94.9 95.0 95.1 95.0 95.1 95.0 95.1 95.0 95.1 95.0 95.1 95.0 95.1 95.0 95.1 6 pole 50.6 56.6 58.2 61.6 67.6 68.8 73.1 75.9 78.1 79.8 81.8 83.3 84.6 86.0 87.2 88.7 89.7 90.4 90.9 91.7 92.2 92.7 93.1 93.7 94.0 94.3 94.6 94.8 95.0 95.0 95.0 95.0 95.0 95.0 95.0 8 pole 39.8 45.9 47.4 50.6 56.1 57.2 61.7 66.2 70.8 74.1 77.6 80.0 81.9 83.8 85.3 86.9 88.0 88.6 89.1 89.8 90.3 90.7 91.0 91.6 91.9 92.3 92.6 93.0 93.5 93.5 93.5 93.5 93.5 93.5 93.5 2 pole 60.8 65.9 67.2 69.7 73.8 74.6 77.8 80.7 82.7 84.2 85.9 87.1 88.1 89.2 90.1 91.2 91.9 92.5 92.7 93.3 93.7 94.0 94.3 94.7 95.0 95.2 95.4 95.6 95.8 95.8 95.8 95.8 95.8 95.8 95.8 4 pole 64.8 69.9 71.1 73.5 77.3 78.0 80.8 82.5 84.1 85.3 86.7 87.7 88.6 89.6 90.4 91.4 92.1 92.6 93.0 93.6 93.9 94.2 94.6 95.0 95.2 95,4 95.6 95.8 96.0 96.0 96.0 96.0 96.0 96.0 96.0 6 pole 57.7 63.9 65.4 68.6 73.5 74.4 77.2 78.9 81.0 82.5 84.3 85.6 86.8 88.0 89.1 90.3 91.2 91.7 92.2 92.9 93.3 93.7 94.1 94.6 94.9 95.1 95.4 95.6 95.8 95.8 95.8 95.8 95.8 95.8 95.8 8 pole 50.7 58.7 60.6 64.1 69.3 70.1 73.0 75.0 77.7 79.7 81.9 83.5 84.8 86.2 87.3 88.6 89.6 90.1 90.6 91.3 91.8 92.2 92.5 93.1 93.4 93.7 94.0 94.3 94.6 94.6 94.6 94.6 94.6 94.6 94.6 2 pole 66.5 70.8 71.9 74.3 78.1 78.9 81.5 83.5 85.2 86.5 88.0 89.1 90.0 90.9 91.7 92.6 93.3 93.7 94.0 94.5 94.8 95.0 95.3 95.6 95.8 96.0 96.2 96.3 96.5 96.5 96.5 96.5 96.5 96.5 96.5 4 pole 69.8 74.7 75.8 77.9 81.1 81.7 83.9 85.7 87.2 88.2 89,5 90.4 91.1 91.9 92.6 93.3 93.9 94.2 94.5 94.9 95.2 95.4 95.7 96.0 96.1 96.3 96.4 96.6 96.7 96.7 96.7 96.7 96.7 96.7 96.7 6 8 pole pole 64.9 62.3 70.1 67.2 71.4 68.4 74.1 70.8 78.0 74.3 78.7 74.9 80.9 77.0 82.7 78.4 84.5 80.8 85.9 82.6 87.4 84.5 88.6 85.9 89.5 87.1 90.5 88.3 91.3 89.3 92.3 90.4 92.9 91.2 93.4 91.7 93.7 92.1 94.2 92.7 94.5 93.1 94.8 93.4 95.1 93.7 95.4 94.2 95.6 94.4 95.8 94.7 96.0 94.9 96.2 95.1 96.3 95.4 96.5 95.4 96.6 95.4 96.6 95.4 96.6 95.4 96.6 95.4 96.6 95.4 6 9AKK105944 EN 02-2020 | ABB Motors and Generators Mounting arrangements Foot-mounted motor Code I / code II IM B3 IM 1001 IM V5 IM 1011 IM V6 IM 1031 Flange-mounted motor, large flange Code I / code II IM B6 IM 1051 IM B7 IM 1061 IM B8 IM 1071 Product code pos. 12 A: foot-mounted, term. box top R: foot-mounted, term. box RHS L: foot-mounted, term. box LHS Product code pos. 12 B: flange mounted, large flange IM B5 IM 3001 IM V1 IM 3011 IM V3 IM 3031 Flange-mounted motor, small flange Code I / code II *) IM 3051 *) IM 3061 *) IM 3071 Product code pos. 12 C: flange mounted, small flange IM B14 IM 3601 IM V18 IM 3611 IM V19 IM 3631 *) IM 3651 Foot- and flange-mounted motor with feet, large flange Code I / code II IM B35 IM 2001 IM V15 IM 2011 IM V35 IM 2031 *) IM 2051 Foot- and flange-mounted motor with feet, small flange Code I / code II *) IM 3661 *) IM 2061 *) IM 3671 *) IM 2071 Product code pos. 12 H: foot/flange-mounted, term. box top S: foot/flange-mounted, term. box RHS T: foot/flange-mounted, term. box LHS Product code pos. 12 J: foot/flange-mounted, small flange IM B34 IM 2101 IM V17 IM 2111 IM 2131 Foot-mounted motor, shaft with free extensions Code I / code II IM 2151 IM 2161 IM 2171 Product code pos. 12 IM 1002 IM 1012 IM 1032 IM 1052 IM 1062 IM 1072 *) Not stated in IEC 60034-7. Note: If the motor is mounted shaft upwards, take measures to prevent water or any other liquid from running down the shaft into the motor. ABB Motors and Generators | 9AKK105944 EN 02-2020 7 General information Cooling Designation system concerning methods of cooling refers to standard IEC 60034-6. Explanation of the product code International Cooling Circuit arrangement Primary coolant Method of movement of Secondary coolant primary coolant IC 4 (A) 1 (A) 1 2 3 4 Position 1 0: Free circulation (open circuit) 4: Free circulatio (open circuit) Method of movement of secondary coolant 6 5 Position 2 A: For air (omitted for simplifi ed designation) Position 3 0: Free convection 1: Self-circulation 6: Machine-mounted independent component Position 4 A: For air (omitted for simplifi ed designation) W: For water Position 5 0: Free convection 1: Self-circulation 6: Machine-mounted independent component 8: Relative displacement 8 9AKK105944 EN 02-2020 | ABB Motors and Generators General information Degrees of protection: IP code/IK code Classification of degrees of protection provided by enclosures of rotating machines are refers to: Standard IEC 60034-5 or EN 60529 for IP code Standard EN 50102 for IK code IP protection Protection of persons against getting in contact with (or approaching) live parts and against contact with moving parts inside the enclosure. Also protection of the machine against ingress of solid foreign objects. Protection of machines against the harmful effects due to the ingress of water. Position 1 2: Motors protected against solid objects greater than 12 mm 4: Motors protected against solid objects greater than 1 mm 5: Dust-protected motors 6: Dust-tight motors IK code Classification of degrees of protection provided by enclosure for motors against external mechanical impacts. Position 1 Relation between IK code and impact energy: IK code Impact energy/Joule 0: Not protected according to EN 50102 01: 0.15 02: 0.2 03: 0.35 04: 0.5 05: 0.7 06: 1 07: 2 08: 5 (ABB Standard) 09: 10 10: 20 Position 2 3: Motors protected against spraying water 4: Motors protected against splashing water 5: Motors protected against water jets 6: Motors protected against heavy seas ABB Motors and Generators | 9AKK105944 EN 02-2020 9 Insulation 01 Safety margins per thermal class. ABB uses class F insulation, which, with temperature rise B, is the most common requirement among industry today. The use of class F insulation with class B temperature rise gives ABB products a 25 °C safety margin. This can be used to increase the loading for limited periods, to operate at higher ambient temperatures or altitudes, or with greater voltage and frequency tolerances. It can also be used to extend insulation. For instance, a 10 K temperature reduction will extend the insulation life. Thermal class 130 (B) Nominal ambient temperature 40 °C Max permissible temperature rise 80 K Hot spot temperature margin 10 K Thermal class 155 (F) Nominal ambient temperature 40 °C Max permissible temperature rise 105 K Hot spot temperature margin 10 K Thermal class 180 (H) Nominal ambient temperature 40 °C Max permissible temperature rise 125 K Hot spot temperature margin 10 K °C 180 10 155 10 130 120 10 40 0 __ 01 80 105 125 40 40 40 B F H 130 155 180 10 9AKK105944 EN 02-2020 | ABB Motors and Generators General information Voltage and frequency 01 Voltage and frequency deviation in zones A and B. The impact on temperature rise caused by voltage and frequency fluctuation is defined in IEC 600341. The standard divides the combinations into two zones, A and B. Zone A is the combination of voltage deviation of +/-5 % and frequency deviation of +/-2 %. Zone B is the combination of voltage deviation of +/-10 % and frequency deviation of +3/-5 %. This is illustrated in figure below. Motors are capable of supplying the rated torque in both zones A and B, but the temperature rise will be higher than at rated voltage and frequency. Motors can be run in zone B only for a short period of time. Y 1.10 Key X axis Y axis 1 2 3 frequency p.u. voltage p.u. zone A zone B (outside zone A rating point 1 3 0.95 2 1.05 1.03 0.98 1.00 1.09 X 1.02 0.93 0.95 0.90 __ 01 ABB Motors and Generators | 9AKK105944 EN 02-2020 11 Surface treatment The surface treatment categorization of ABB motors is based on the ISO 12944 standard. ISO 12994-5 divides paint system durability into three categories: low (L), medium (M), and high (H). Low durability corresponds to a lifetime of 2 - 5 years, medium to 5 15 years, and high durability to over 15 years. The durability range is not a guaranteed lifetime. Its purpose is to help the owner of the motor plan for appropriate maintenance intervals. More frequent maintenance may be required because of fading, chalking, contamination, wear and tear, or for other reasons. ABB's standard surface treatment is corrosivity category C3, durability range M (which equal to medium corrosivity and medium durability). Special surface treatment is available in corrosivity categories C4 and C5-M, durability class M for both. In addition, surface treatment according to the NORSOK standard for offshore environments is available as an option. The standard ABB paint color for motors is Munsell blue 8B 4.5/3.25. Corrosivity category C1, very low C2, low C3, medium C4, high C5-I, very high (industrial) C5-M, very high (marine) Outdoor atmospheres Not used Atmospheres with low level pollution, mostly rural areas. Urban and industrial atmospheres, moderate sulfur dioxide pollution. Coastal areas with low salinity. Industrial areas and coastal areas with moderate salinity. Industrial areas and coastal areas with high humidity and aggressive atmosphere. Coastal and offshore areas with high salinity. Indoor atmospheres Use in ABB motors Heated buildings with clean atmospheres Not available Unheated buildings where Not available condensation may occur, such as depots and sports halls. Production rooms with high Standard treatment humidity and some air pollution; food processing plants, laundries, breweries, dairies. Chemical plants, swimming pools, coastal ship- and Optional treatment for cast iron motors, variant code 115 boatyards. Buildings or areas with nearly permanent condensation and high pollution. Not available Buildings or areas with nearly permanent condensation and high pollution. Optional treatment for cast iron motors, variant code 754, 711 Atmospheric corrosivity categories and recommended environments. 12 9AKK105944 EN 02-2020 | ABB Motors and Generators Variable-speed drives with process performance motors Frequency converters provide significant benefits when used together with ABB process performance motors. The advantages include better process control and energy savings through regulation of motor speed, and smooth starting with reduced inrush current, reducing the stress on the equipment and supply network. By choosing an ABB motordrive package, users can be confident that the motor and drive combination is optimized for their application; it is a working package with known performance, as the combination has been tested and verified. Process performance motors are designed for both DOL and variable-speed operation, and will, either as standard or by adding a few extras, be suitable for variable-speed operation. When selecting process performance motors for VSDs, the following points must be taken into consideration. The DriveSize selection software available at www.abb.com helps in selecting the optimal combination of motor, drive and supply transformer. Operating speed Process performance motors are designed to work over a wide speed range and also at speeds significantly higher than nominal. The maximum speeds can be found on motor rating plates or in DriveSize. In addition to motor speed, make sure that the maximum or critical speed of the entire application is not exceeded. Guideline maximum speed values for process performance motors are shown in Table 1. Motor size 71-80 90-100 112-200 225-250 280 315 355 SM, ML, LKA 355 LKB 400 450 Maximum speed, r/min 2-pole motors 6000 6000 4500 3600 3600 3600 3600 3000 3600 3000 4-pole motors 4000 6000 4500 3600 2000 2200 2200 2200 2200 2200 Table 1. Guideline maximum speed values for process performance motors. Ventilation When the motor is operating at low speeds, the cooling capacity of the fan decreases, which again reduces the motor's load capacity. A separate, constant-speed fan (variant codes 183, 422, 514) can be used to increase cooling capacity at low speed if required for loads with constant torque characteristics. Lubrication The lubrication interval of regreasable bearings depends on the running speed of the motor and the bearing temperature. Motors in frame size 280 and larger are delivered as standard with a lubrication plate in tabular format that states the relubrication intervals at different speeds and temperatures. A similar plate is optional for sizes 160250 and can be ordered using variant code 795. Smaller motors usually have greased, sealed-for-life bearings. Please refer to the installation, operation and safety manual for further information on lubrication. Winding insulation To ensure that motors operate reliably, the effects of non-sinusoidal output voltages from the converter must be taken into consideration when selecting the correct insulation system for the motor and output filters for the converter. The insulation and filters must be selected according to Table 2. Winding insulation and filters required UN 500 V UN 600 V Standard insulation Standard insulation + dU/dt filters OR Special insulation (variant code 405) UN 690 V Special insulation (variant code 405) AND dU/dt-filters at converter output 600 V < UN 690 V cable length > 150 m Special insulation (variant code 405) Table 2. Selection of motor winding insulation and converter output filters For more information on dU/dt filters, see the relevant ABB drives catalogs. For other converters and cases where the guidelines shown in Table 2 cannot be applied, selection must be based on the voltages present at the motor terminals. ABB Motors and Generators | 9AKK105944 EN 02-2020 13 01 Maximum allowed phase-to-phase voltage peaks at motor terminals, as a function pulse rise time. Allowed phase-to-ground voltage peaks at motor terminals: 1,300 V peak: standard insulation 1,800 V peak: special insulation, variant code 405 The maximum allowed phase-to-phase voltage peaks at the motor terminals as a function of pulse rise time are shown in Figure 01. The higher curve (special insulation) applies to motors with special winding insulation for frequency converter supply (variant code 405). Standard insulation applies to motors with a standard design. Peak voltage ULL, kV 2,20 2,00 1,80 1,60 1,40 1,20 1,00 0,80 0,00 0,20 0,40 0,60 Rise time 10-90 %, µs 0,80 ABB Special Insul. ABB Standard Insul. 1,00 1,20 __ 01 Bearing currents Bearing voltages and currents must be avoided in all motors to ensure reliable operation of the entire application. Table 3 gives the selection rules depending on motor output power and frame size when used together with ABB converters; the same rules can also be applied as guidance when using ABB process performance motors with other converters. Nominal power (PN and / or Frame size (IEC) PN < 100 kW PN 100 kW OR IEC 315 Frame size IEC 355 PN 350 kW OR IEC 400 Frame size IEC 450 Precautionary measures No action needed Insulated non-drive end bearing Insulated non-drive end bearing AND Common mode filter at the converter Table 3. Precautionary measures to avoid bearing currents in variable speed drives. Common mode filters Common mode filters are installed at the output of the frequency converter. These filters reduce common mode currents and so decrease the risk of bearing currents. Common mode filters do not significantly affect the phase of main voltages on motor terminals. For more information, see ABB drives catalogs. Insulated bearings ABB uses bearings with an insulated outer race or hybrid bearings with ceramic rolling elements. Insulated bearings at the non-drive end should be selected as indicated in Table 3. This solution can be ordered using variant code 701. Earthing and cabling For motors with a nominal power above 30 kW, cables with a symmetrical concentric protective earth should be used across the system. The same type of cables are also recommended for motors with an output of 30 kW and below. Solutions for persistent bearing currents In very rare cases, bearing currents might still exist even if the measures specified above have been taken. For such installations, there are two advanced methods that would provide a remedy: either a shaft grounding bush, or insulated bearings at both ends. The shaft grounding bush is installed inside the motor to protect it from the environment and ensure good grounding of the shaft. The shaft grounding brush can be ordered using variant code 588. The second advanced solution is to mount insulated bearings at both ends. These can either be bearings with an insulated out race, or hybrid bearings with ceramic rolling elements. Insulated bearings at both ends can be ordered using variant code 702. Note that this variant cannot be combined with special drive-end bearing solutions, such as roller bearings or angular contact ball bearings. Electromagnetic compatibility (EMC) The high-frequency components in a variablespeed drive might cause electromagnetic interference with other equipment in the installation. To avoid this, certain measures should be taken. To meet EMC requirements, special EMC cables glands with a 360° connection to the concentric protective earth conductor should be used. Such cable glands can be used with variant code 704. Motor loadability with frequency converter drives The difference in the temperature rise of a motor run direct on line compared to the same motor run with a converter is influenced by factors such as the cooling effect of a shaft-mounted fan depending on the speed of the motor, increased losses due to harmonics generated by the converter and reduced flux above the field weakening point. The effects of all these factors are combined in the loadability curves. The loadability curves shown in Figures 02-05 are generic and give indicative guidelines for dimensioning standard low-voltage motors used with a frequency converter. The curves show the maximum continuous load torque as a function of frequency (speed), which results in the same temperature rise as opera- 14 9AKK105944 EN 02-2020 | ABB Motors and Generators tion with the rated sinusoidal supply at nominal frequency and full rated load. Normally, process performance motors operate according to a class B temperature rise. For these motors, dimensioning should be according to the temperature rise B curve, or the motor can be slightly overloaded. In other words, it can be dimensioned according to the temperature rise F curve. However, if only a class F temperature rise with a sinusoidal supply is indicated for the motor in the technical data section, dimensioning must be done according to temperature rise curve B. If the motor is loaded according the temperature rise F curve, it will be necessary to check the temperature rise in other parts of the motor and ensure that the lubrication intervals and grease type are still appropriate. ABB Motors and Generators | 9AKK105944 EN 02-2020 15 02 Loadability curves for ABB frequency converters with DTC control. 03 Loadability curves for other frequency converters. 04 Loadability curves for ABB frequency converters with DTC control. 05 Loadability curves for other frequency converters. Curves are valid for a field weakening point of 50 Hz. Temperature rise B T/TN (%) 120 Separate cooling 100 80 Sizes 80-132 Sizes 160-450 60 40 Temperature rise F T/TN (%) 120 Separate cooling 100 80 Sizes 80-132 Sizes 160-450 60 40 0 0 __ 02 20 40 60 80 100 Frequency (Hz) 0 0 __ 04 20 40 60 80 100 Frequency (Hz) Temperature rise B T/TN (%) 120 Separate cooling 100 Temperature rise F T/TN (%) 120 Separate cooling 100 80 Sizes 80-132 60 Sizes 160-450 40 80 Sizes 80-132 60 Sizes 160-450 40 0 0 __ 03 20 40 60 80 100 Frequency (Hz) 0 0 __ 05 20 40 60 80 100 Frequency (Hz) 16 9AKK105944 EN 02-2020 | ABB Motors and Generators Low voltage Process performance cast iron motors 18 Ordering information 19 Rating plates 20 Technical data IE2 37 Technical data IE3 50 Technical data IE4 56 Variant codes 63 Mechanical design 63 Motor frame and drain holes 66 Bearings 77 Terminal box 86 Dimension drawings 86 IE2 cast iron motors 88 IE3 cast iron motors 90 IE4 cast iron motors 91 Accessories 91 Built-in brake 94 Separate cooling 96 Silencer 97 Slide rails 99 Cast iron motors in brief 102 Motor construction ABB Motors and Generators | 9AKK105944 EN 02-2020 17 Ordering information Explanation of the product code Motor type Motor size Product code Mounting arrangement code, Variant codes Voltage and frequency code, Generation code M3BP 160MLA 3GBP 161 410 - ADG 003, etc. 1 2 3 4 5 67 8 9 10 11 12 13 14 Positions 1 to 4 3GBP Totally enclosed fan cooled squirrel cage motor with cast iron frame Positions 5 and 6 IEC size 07: 71 08: 80 09: 90 10: 100 12: 112 13: 132 16: 160 18: 180 IEC size 20: 200 22: 225 25: 250 28: 280 31: 315 35: 355 40: 400 45: 450 Position 7 Speed (Pole pairs) 1: 2 poles 2: 4 poles 3: 6 poles 4: 8 poles 5: 10 poles 6: 12 poles 7: > 12 poles 8: Two-speed motors for fan drive motors for constant torque 9: Multi-speed motors, two-speed Positions 8 to 10 Serial number Position 11 -(dash) Position 12 (marked with black dot in data tables) Mounting arrangement A: Foot-mounted, top-mounted terminal box R: Foot-mounted, terminal box RHS seen from D-end L: Foot-mounted, terminal box LHS seen from D-end B: Flange-mounted, large flange C: Flange-mounted, small flange (sizes 71 to 112) H: Foot- and flange-mounted, terminal box top-mount- ed Position 12 (marked with black dot in data tables) J: Foot- and flange-mounted, small flange with tapped holes S: Foot- and flange-mounted, terminal box RHS seen from D-end T: Foot- and flange-mounted, terminal box LHS seen from D-end V: Flange-mounted, special flange F: Foot- and flange-mounted. Special flange Position 13 (marked with black dot in data tables) Voltage and frequency Single-speed motors B: 380 V 50 Hz D: 400 V, 415 V, 690 VY 50 Hz E: 500 V 50 Hz F: 500 VY 50 Hz S: 230 V, 400 VY, 415 VY 50 Hz T: 660 V 50 Hz U: 690 V 50 Hz X: Other rated voltage, connection or frequency, 690 V maximum Position 14 Generation code A, B, C...G...K: The product code must be, if needed, followed by variant codes. Efficiency values are given according to IEC 600342-1; 2014 For detailed dimension drawings please see our web-pages `www.abb.com/motors&generators' or contact ABB. 18 9AKK105944 EN 02-2020 | ABB Motors and Generators Rating plates 01 Rating plate example, motor size 100, IE2. 02 Rating plate example, motor size 160, K generation, IE3. 03 Rating plate example, motor size 315, L generation, IE3. 04 Rating plate example, motor size 315, IE4. The motor's main rating plate shows the motor's performance values with various connections at nominal speed. The rating plate also shows the efficiency level (IE2, IE3, or IE4), year of manufacture, and the lowest nominal efficiency at 100, 75, and 50 % nominal load. The plate samples shown on this page present typical data rows. The actual content of the plate may vary according to your order and according to the motor's IE class. __ __ 01 03 __ __ 02 04 ABB Motors and Generators | 9AKK105944 EN 02-2020 19 Technical data, 400 V 50 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3000 r/min = 2 poles 0.37 M3BP 71MA 2 3GBP071321-··B 0.55 M3BP 71MB 2 3GBP071322-··B 0.75 M3BP 80MB 2 3GBP081322-··B 1.1 M3BP 80MC 2 3GBP081323-··B 1.5 M3BP 90SLB 2 3GBP091322-··B 2.2 M3BP 90SLC 2 3GBP091323-··B 3 M3BP 100LB 2 3GBP101322-··B 4 M3BP 112MB 2 3GBP111322-··B 5.5 M3BP 132SMB 2 3GBP131322-··B 7.5 M3BP 132SMC 2 3GBP131324-··B 11 M3BP 160MLA 2 3GBP161410-··G 15 M3BP 160MLB 2 3GBP161420-··G 18.5 M3BP 160MLC 2 3GBP161430-··G 22 M3BP 180MLA 2 3GBP181410-··G 30 M3BP 200MLA 2 3GBP201410-··G 37 M3BP 200MLB 2 3GBP201420-··G 45 M3BP 225SMA 2 3GBP221210-··G 55 M3BP 250SMA 2 3GBP251210-··G 75 M3BP 280SMA 2 3GBP281210-··N 90 M3BP 280SMB 2 3GBP281220-··N 110 M3BP 315SA 2 3GBP311110-··N 132 M3BP 315SMA 2 3GBP311210-··N 160 M3BP 315SMB 2 3GBP311220-··N 200 1) M3BP 315MLA 2 3GBP311410-··G 250 1) M3BP 355SMA 2 3GBP351210-··G 315 1) M3BP 355SMB 2 3GBP351220-··G 355 1) M3BP 355SMC 2 3GBP351230-··G 400 1) M3BP 355MLA 2 3GBP351410-··G 450 1) M3BP 355MLB 2 3GBP351420-··G 500 1) M3BP 355LKA 2 3GBP351810-··G 560 1) M3BP 400LA 2 3GBP401510-··G 560 2) M3BP 400LKA 2 3GBP401810-··G 560 1) M3BP 355LKB 2 3GBP351820-··G 630 2) M3BP 400LB 2 3GBP401520-··G 630 2) M3BP 400LKB 2 3GBP401820-··G 710 2) M3BP 400LC 2 3GBP401530-··G 710 2) M3BP 400LKC 2 3GBP401830-··G 800 2)3) M3BP 450LA 2 3GBP451510-··G 900 2)3) M3BP 450LB 2 3GBP451520-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 2768 2813 2895 2870 2900 2885 2925 2895 2865 2890 2938 2934 2932 2952 2956 2959 2961 2967 2972 2970 2978 2976 2975 2980 2984 2980 2984 2982 2983 2982 2988 2988 2983 2987 2987 2987 2987 2990 2990 400 V 50 Hz 74.8 75.4 77.8 78.3 80.6 79.6 81.8 81.7 82.2 82.9 83.2 85.5 85.2 84.9 86.1 87.0 87.7 88.4 88.2 88.8 90.6 91.5 91.5 92.4 92.0 93.1 92.2 92.7 93.1 93.5 93.4 93.7 93.6 93.9 94.1 94.4 93.8 94.0 94.1 94.3 94.3 94.2 94.6 94.6 94.8 94.9 95.7 95.7 95.7 95.5 95.7 95.6 95.7 95.7 96.5 96.3 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 97.0 97.0 96.5 96.2 96.5 96.2 96.5 96.3 96.5 96.3 96.5 96.2 96.5 96.2 72.4 76.0 75.6 78.9 81.3 84.3 82.7 86.6 87.7 87.6 91.1 92.2 93.1 92.2 92.8 92.9 93.1 93.8 93.4 93.8 93.3 93.8 94.4 94.9 94.5 94.9 94.9 95.6 95.7 96.0 95.7 95.7 96.5 95.6 95.6 95.7 95.7 95.4 95.5 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.78 0.89 4.5 1.27 2.2 2.3 0.00039 0.79 1.29 4.3 1.86 2.4 2.5 0.00051 0.74 1.8 7.7 2.4 4.2 4.2 0.001 0.80 2.44 7.5 3.63 3.7 4.6 0.0012 0.87 3.26 7.5 4.9 2.5 2.6 0.00254 0.88 4.2 6.8 7.2 1.9 2.5 0.0028 0.87 5.75 9.1 9.7 3.1 3.5 0.00528 0.89 7.52 8.1 13.1 2.9 3.2 0.00575 0.86 10 7.0 18.3 2.6 2.7 0.0128 0.89 13.7 7.3 24.9 2.6 3.6 0.0136 0.90 19.2 7.5 35.7 2.4 3.1 0.044 0.90 26 7.5 48.8 2.5 3.3 0.053 0.92 31.5 7.5 60.2 2.9 3.4 0.063 0.87 39.6 7.7 71.1 2.8 3.3 0.076 0.90 51.6 7.7 96.9 2.7 3.1 0.178 0.90 63.5 8.2 119 3.0 3.3 0.196 0.88 78.8 6.7 145 2.5 2.5 0.244 0.88 95.8 6.8 177 2.2 2.7 0.507 0.89 128 7.8 241 2.5 3.0 0.61 0.91 149 7.5 289 2.7 3.1 0.73 0.90 187 7.6 353 2.4 3.1 0.95 0.90 223 7.3 423 2.5 3.0 1.1 0.90 268 7.3 513 2.4 3.0 1.25 0.90 335 7.7 640 2.6 3.0 2.1 0.89 423 7.7 800 2.1 3.3 3 0.89 531 7.0 1009 2.1 3.0 3.4 0.88 603 7.2 1136 2.2 3.0 3.6 0.88 677 7.1 1280 2.3 2.9 4.1 0.90 743 7.9 1440 2.2 2.9 4.3 0.90 827 7.5 1601 2.0 3.9 4.8 0.89 934 7.8 1789 2.5 3.7 7.9 0.89 934 7.8 1789 2.5 3.7 7.9 0.90 925 8.0 1792 2.2 4.1 5.2 0.89 1049 7.6 2014 2.6 3.7 8.2 0.89 1049 7.6 2014 2.6 3.7 8.2 0.89 1178 7.2 2270 2.6 3.4 9.3 0.89 1178 7.2 2270 2.6 3.4 9.3 0.87 1362 7.8 2555 1.3 3.4 12.2 0.87 1534 7.6 2874 1.5 3.1 13.5 Weight kg Sound pressure Level LPA dB 11 58 11 56 16 57 18 60 24 69 25 64 36 68 37 70 68 70 70 70 127 69 141 69 170 69 190 69 283 72 298 72 347 74 405 75 540 77 590 77 770 78 865 78 925 78 1190 78 1600 83 1680 83 1750 83 2000 83 2080 83 2320 83 2950 82 2950 82 2460 83 3050 82 3050 82 3300 82 3300 82 4000 4200 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 20 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3000 r/min = 2 poles 22 M3BP 160MLD 2 3GBP161440-··G 27 M3BP 160MLE 2 3GBP161450-··G 30 M3BP 180MLB 2 3GBP181420-··G 45 3) M3BP 200MLC 2 3GBP201430-··G 55 3) M3BP 200MLD 2 3GBP201440-··G 55 M3BP 225SMB 2 3GBP221220-··G 75 3) M3BP 225SMC 2 3GBP221230-··G 75 M3BP 250SMB 2 3GBP251220-··G 80 3) M3BP 225SMD 2 3GBP221240-··G 90 3) M3BP 250SMC 2 3GBP251230-··G 110 1) M3BP 280SMC 2 3GBP281230-··G 132 1) M3BP 280MLA 2 3GBP281410-··G 160 1) M3BP 280MLB 2 3GBP281420-··G 250 1) M3BP 315LKA 2 3GBP311810-··G 315 1)3) M3BP 315LKC 2 3GBP311830-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 2933 2939 2950 2957 2953 2961 2969 2970 2964 2971 2978 2977 2976 2980 2981 400 V 50 Hz 91.7 92.8 92.2 93.1 92.7 93.5 93.3 93.8 93.8 94.4 93.9 94.3 94.4 94.6 94.5 94.8 94.4 94.8 94.9 95.2 95.1 95.1 95.3 95.3 95.5 95.7 95.7 95.7 95.7 95.7 92.8 93.0 93.3 93.2 94.3 93.6 94.0 94.4 94.3 94.8 94.5 94.8 95.3 95.2 95.4 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.90 38 8.1 71.6 3.2 3.6 0.063 0.90 46.4 8.8 87.7 3.4 3.8 0.072 0.88 53 7.9 97.1 2.8 3.3 0.092 0.88 79.1 7.9 145 3.1 3.3 0.196 0.89 95 7.8 177 2.9 3.3 0.217 0.88 96 6.5 177 2.4 2.5 0.274 0.84 136 7.4 241 3.2 3.1 0.309 0.89 128 7.6 241 2.8 3.1 0.583 0.87 140 7.3 257 3.0 2.8 0.329 0.89 153 7.6 289 2.5 3.1 0.644 0.90 186 7.9 352 2.4 3.0 1.15 0.90 221 7.5 423 2.5 3.0 1.4 0.91 265 7.6 513 2.8 3.0 1.55 0.89 423 7.6 801 2.8 2.9 2.65 0.89 533 8.8 1009 3.2 3.2 3.3 Weight kg Sound pressure Level LPA dB 170 69 184 69 208 69 298 72 314 72 369 74 396 74 451 75 410 74 487 75 725 77 840 81 890 81 1440 78 1630 78 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 ABB Motors and Generators | 9AKK105944 EN 02-2020 21 Technical data, 400 V 50 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1500 r/min = 4 poles 0.25 M3BP 71MA 4 3GBP072321-··B 0.37 M3BP 71MB 4 3GBP072322-··B 0.55 M3BP 80MA 4 3GBP082321-··B 0.75 M3BP 80MD 4 3GBP082324-··B 1.1 M3BP 90SLB 4 3GBP092322-··B 1.5 M3BP 90SLD 4 3GBP092325-··B 2.2 M3BP 100LC 4 3GBP102323-··B 3 M3BP 100LD 4 3GBP102324-··B 4 M3BP 112MB 4 3GBP112322-··B 5.5 M3BP 132SMB 4 3GBP132322-··B 7.5 M3BP 132SMC 4 3GBP132323-··B 11 M3BP 160MLA 4 3GBP162410-··G 15 M3BP 160MLB 4 3GBP162420-··G 18.5 M3BP 180MLA 4 3GBP182410-··G 22 M3BP 180MLB 4 3GBP182420-··G 30 M3BP 200MLA 4 3GBP202410-··G 37 M3BP 225SMA 4 3GBP222210-··G 45 M3BP 225SMB 4 3GBP222220-··G 55 M3BP 250SMA 4 3GBP252210-··G 75 M3BP 280SMA 4 3GBP282210-··N 90 M3BP 280SMB 4 3GBP282220-··N 110 M3BP 315SA 4 3GBP312110-··N 132 M3BP 315SMA 4 3GBP312210-··N 160 M3BP 315SMB 4 3GBP312220-··N 200 M3BP 315MLA 4 3GBP312410-··G 250 M3BP 355SMA 4 3GBP352210-··G 315 M3BP 355SMB 4 3GBP352220-··G 355 M3BP 355SMC 4 3GBP352230-··G 400 M3BP 355MLA 4 3GBP352410-··G 450 M3BP 355MLB 4 3GBP352420-··G 500 M3BP 355LKA 4 3GBP352810-··G 560 3) M3BP 355LKB 4 3GBP352820-··G 560 3) M3BP 400LA 4 3GBP402510-··G 560 3) M3BP 400LKA 4 3GBP402810-··G 630 M3BP 400LB 4 3GBP402520-··G 630 M3BP 400LKB 4 3GBP402820-··G 710 3) M3BP 400LC 4 3GBP402530-··G 710 3) M3BP 400LKC 4 3GBP402830-··G 800 M3BP 450LA 4 3GBP452510-··G 900 M3BP 450LB 4 3GBP452520-··G 1000 3) M3BP 450LC 4 3GBP452530-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1365 1380 1415 1430 1435 1430 1450 1450 1440 1460 1450 1466 1470 1477 1475 1480 1479 1480 1480 1481 1481 1484 1482 1483 1486 1488 1488 1487 1489 1490 1490 1490 1491 1491 1491 1491 1491 1491 1491 1492 1491 400 V 50 Hz 68.5 70.9 71.6 73.8 70.0 71.3 81.0 81.0 81.4 82.0 84.3 85.1 85.9 85.1 86.8 86.9 86.6 87.2 89.0 89.8 89.3 90.1 90.4 91.6 91.4 92.3 91.9 92.8 92.3 93.3 93.2 94.0 93.4 93.9 93.9 94.3 94.4 94.9 94.0 94.3 94.2 94.2 94.5 94.9 94.7 95.1 94.9 95.2 95.6 95.6 95.9 96.0 95.9 96.2 95.9 96.2 96.0 96.0 96.0 96.1 96.7 96.7 96.9 96.9 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.5 96.7 96.7 69.8 74.0 68.7 78.2 80.1 83.9 83.4 85.3 86.8 88.9 90.0 91.3 92.2 92.6 93.2 93.7 93.4 93.9 94.6 93.8 94.3 94.7 95.0 94.9 95.3 95.5 95.8 95.9 95.5 95.6 96.1 96.5 96.1 96.1 96.1 96.1 96.2 96.2 96.1 96.0 96.1 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.81 0.63 3.5 1.74 1.9 2.0 0.00074 0.83 0.87 4.6 2.5 1.6 2.1 0.00088 0.80 1.45 4.5 3.7 2.0 2.5 0.00144 0.73 1.82 6.3 5 3.3 3.6 0.002 0.80 2.36 6.5 7.3 2.4 3.4 0.0044 0.83 3 6.3 10 2.7 3.4 0.0053 0.78 4.6 7.7 14.5 2.7 4.1 0.0095 0.79 6.1 7.7 19.8 2.9 3.6 0.011 0.82 7.94 7.0 26.5 2.5 2.9 0.0125 0.80 10.8 7.1 36 2.2 3.2 0.0328 0.81 14.5 7.2 49.4 2.5 3.5 0.0366 0.84 20.9 6.8 71.6 2.2 2.8 0.081 0.83 28.5 7.1 97.4 2.6 3.0 0.099 0.84 34.5 7.2 119 2.6 2.9 0.166 0.84 40.9 7.3 142 2.6 3.0 0.195 0.84 55.3 7.4 193 2.8 3.0 0.309 0.84 68 7.1 238 2.6 2.9 0.356 0.85 81.3 7.5 290 2.8 3.2 0.44 0.85 98.9 7.0 354 2.6 2.9 0.765 0.83 137 7.7 483 3.3 3.4 0.91 0.85 161 7.5 580 2.9 3.3 1.13 0.86 195 6.8 707 2.7 2.9 1.5 0.88 229 6.7 850 2.4 2.7 2 0.86 282 7.0 1030 2.6 2.9 2.2 0.86 351 7.2 1285 2.5 2.9 3.5 0.85 442 7.1 1604 2.3 2.7 5.9 0.86 550 7.3 2021 2.3 2.8 6.9 0.87 614 6.8 2279 2.4 2.7 7.2 0.85 705 6.8 2565 2.3 2.6 8.4 0.86 780 6.9 2884 2.3 2.9 8.4 0.86 865 6.8 3204 2.0 3.0 10 0.85 981 7.2 3588 2.6 2.7 10.6 0.85 982 7.4 3586 2.4 2.8 15 0.85 982 7.4 3586 2.4 2.8 15 0.87 1077 7.6 4034 2.2 2.9 16 0.87 1077 7.6 4034 2.2 2.9 16 0.86 1227 7.6 4547 2.4 3.0 17 0.86 1227 7.6 4547 2.4 3.0 17 0.86 1396 7.0 5121 1.3 2.8 23 0.86 1573 7.0 5761 1.3 2.8 25 0.86 1724 6.8 6404 1.3 2.7 30 Weight kg Sound pressure Level LPA dB 10 45 11 45 15 45 17 50 25 50 27 56 36 56 38 58 44 59 70 67 73 64 135 62 165 62 205 62 222 62 291 63 324 66 356 66 414 67 540 70 610 70 740 68 900 68 940 68 1160 70 1610 74 1780 74 1820 78 2140 78 2140 78 2500 78 2600 78 3200 78 3200 78 3300 78 3300 78 3400 78 3400 78 4050 85 4350 85 4700 85 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 22 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1500 r/min = 4 poles 18.5 M3BP 160MLC 4 3GBP162430-··G 22 3) M3BP 160MLD 4 3GBP162440-··G 30 3) M3BP 180MLC 4 3GBP182430-··G 37 M3BP 200MLB 4 3GBP202420-··G 45 3) M3BP 200MLC 4 3GBP202430-··G 55 M3BP 225SMC 4 3GBP222230-··G 64 M3BP 225SMD 4 3GBP222240-··G 75 3) M3BP 250SMB 4 3GBP252220-··G 90 3) M3BP 250SMC 4 3GBP252230-··G 110 M3BP 280SMC 4 3GBP282230-··G 132 M3BP 280MLA 4 3GBP282410-··G 160 M3BP 280MLB 4 3GBP282420-··G 250 M3BP 315LKA 4 3GBP312810-··G 280 M3BP 315LKB 4 3GBP312820-··G 315 M3BP 315LKC 4 3GBP312830-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1469 1466 1474 1479 1479 1478 1480 1478 1478 1485 1483 1484 1487 1487 1488 400 V 50 Hz 91.4 91.9 91.6 92.4 92.3 92.8 93.4 94.4 93.6 94.4 94.0 94.6 94.2 94.6 94.4 95.1 94.6 95.3 95.1 95.4 95.3 95.5 95.6 95.9 95.7 95.8 95.8 95.9 95.8 95.9 91.7 92.5 92.7 94.4 94.2 94.4 94.1 94.8 95.0 95.1 95.1 95.7 95.2 95.4 95.3 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.84 34.7 7.6 120 3.0 3.2 0.11 0.86 40.8 6.9 143 2.5 2.9 0.125 0.83 56.5 7.3 194 2.7 2.9 0.217 0.85 67.2 7.1 238 2.6 2.9 0.343 0.83 83.6 7.5 290 2.9 3.2 0.366 0.85 99.3 7.4 355 2.9 3.1 0.474 0.85 115 8.0 412 3.3 3.3 0.542 0.85 134 7.3 484 2.8 3.1 0.866 0.84 163 7.4 581 3.1 3.3 0.941 0.86 193 7.6 707 3.0 3.0 1.85 0.86 232 7.0 849 2.7 2.8 2.3 0.85 284 7.4 1029 2.9 2.9 2.5 0.85 443 7.4 1605 2.5 2.9 4.4 0.87 491 7.6 1798 2.6 3.0 5 0.86 559 7.8 2021 2.6 3.2 5.5 Weight kg Sound pressure Level LPA dB 173 62 187 62 235 62 307 63 319 63 370 66 399 66 450 67 478 67 725 68 840 75 890 75 1410 78 1520 78 1600 78 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 ABB Motors and Generators | 9AKK105944 EN 02-2020 23 Technical data, 400 V 50 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1000 r/min = 6 poles 0.18 M3BP 71MA 6 3GBP073321-··B 0.25 M3BP 71MB 6 3GBP073322-··B 0.37 M3BP 80MA 6 3GBP083321-··B 0.55 M3BP 80MB 6 3GBP083322-··B 0.75 M3BP 90SLC 6 3GBP093323-··B 1.1 M3BP 90SLE 6 3GBP093324-··B 1.5 M3BP 100L 6 3GBP103322-··B 2.2 M3BP 112MB 6 3GBP113322-··B 3 M3BP 132SMB 6 3GBP133321-··B 4 M3BP 132SMC 6 3GBP133322-··B 5.5 M3BP 132SMF 6 3GBP133324-··B 7.5 M3BP 160MLA 6 3GBP163410-··G 11 M3BP 160MLB 6 3GBP163420-··G 15 M3BP 180MLA 6 3GBP183410-··G 18.5 M3BP 200MLA 6 3GBP203410-··G 22 M3BP 200MLB 6 3GBP203420-··G 30 M3BP 225SMA 6 3GBP223210-··G 37 M3BP 250SMA 6 3GBP253210-··G 45 M3BP 280SMA 6 3GBP283210-··N 55 M3BP 280SMB 6 3GBP283220-··N 75 M3BP 315SA 6 3GBP313110-··N 90 M3BP 315SMA 6 3GBP313210-··N 110 M3BP 315SMB 6 3GBP313220-··N 132 M3BP 315MLA 6 3GBP313410-··G 160 M3BP 355SMA 6 3GBP353210-··G 200 M3BP 355SMB 6 3GBP353220-··G 250 M3BP 355SMC 6 3GBP353230-··G 315 M3BP 355MLB 6 3GBP353420-··G 355 M3BP 355LKA 6 3GBP353810-··G 400 3) M3BP 355LKB 6 3GBP353820-··G 400 M3BP 400LA 6 3GBP403510-··G 400 M3BP 400LKA 6 3GBP403810-··G 450 M3BP 400LB 6 3GBP403520-··G 450 M3BP 400LKB 6 3GBP403820-··G 500 M3BP 400LC 6 3GBP403530-··G 500 M3BP 400LKC 6 3GBP403830-··G 560 M3BP 400LD 6 3GBP403540-··G 560 M3BP 400LKD 6 3GBP403840-··G 630 M3BP 450LA 6 3GBP453510-··G 710 M3BP 450LB 6 3GBP453520-··G 800 3) M3BP 450LC 6 3GBP453530-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 900 63.7 63.8 915 67.2 65.5 925 67.6 66.5 920 73.1 74.2 960 76.3 74.7 930 78.2 78.7 950 81.3 82.1 950 82.5 83.7 975 85.3 84.2 960 84.9 85.4 965 86.1 86.6 975 88.5 89.9 972 89.3 90.6 977 90.2 90.6 988 91.6 92.2 987 92.0 92.9 986 92.6 93.3 989 93.1 93.8 989 92.7 93.0 990 93.1 93.7 989 93.7 94.1 990 94.0 94.3 990 94.3 94.5 991 95.0 95.0 991 95.3 95.4 993 95.4 95.6 993 95.7 95.8 992 95.7 96.0 992 95.7 95.9 992 96.0 96.0 993 95.8 95.8 993 95.8 95.8 994 95.8 95.8 994 95.8 95.8 993 95.8 95.6 993 95.8 95.6 993 96.6 96.6 993 96.6 96.6 994 95.8 95.9 995 96.6 96.7 995 96.6 96.6 59.0 59.5 60.9 71.9 69.5 76.5 80.7 81.6 81.2 83.9 85.5 89.7 90.5 90.0 91.7 92.7 92.8 93.4 92.4 93.4 93.9 93.7 94.0 94.6 94.9 95.2 95.4 95.5 95.4 95.5 95.1 95.1 95.2 95.2 95.2 95.2 96.0 96.0 95.3 96.1 96.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.71 0.57 3.1 1.91 2.0 2.1 0.00089 0.69 0.77 3.7 2.6 2.6 2.7 0.0011 0.69 1.09 4.1 3.8 2.4 2.5 0.0019 0.71 1.51 3.8 5.7 1.8 2.2 0.00239 0.58 2.3 4.5 7.4 2.4 3.1 0.00491 0.66 3.0 4.0 11.2 1.9 2.3 0.0054 0.69 3.7 4.3 15 1.5 2.7 0.00873 0.69 5.5 4.4 22.1 1.7 2.3 0.0125 0.63 8.0 5.5 29.4 1.8 2.9 0.0334 0.68 10 5.0 39.7 2.0 2.6 0.0334 0.71 12.9 5.1 54.4 2.0 2.3 0.0487 0.79 15.4 7.4 73.4 1.7 3.2 0.087 0.79 22.5 7.5 108 1.9 2.9 0.114 0.76 31.5 5.8 146 1.8 2.7 0.168 0.80 36.4 6.7 178 2.3 2.9 0.382 0.82 42 6.6 212 2.2 2.8 0.448 0.83 56.2 7.0 290 2.6 2.9 0.663 0.82 69.9 6.8 357 2.4 2.7 1.13 0.82 85.2 6.8 434 2.6 2.7 1.36 0.82 102 7.5 530 3.0 3.3 1.8 0.84 138 7.0 724 2.6 2.6 2.6 0.82 169 7.0 868 2.7 2.9 2.8 0.82 205 7.3 1061 2.9 3.0 3.5 0.83 201 7.4 1059 2.5 2.9 4.9 0.83 240 7.5 1271 2.7 3.0 5.8 0.83 291 7.0 1538 2.0 2.6 7.9 0.82 460 7.4 2404 2.6 2.9 11.3 0.83 570 7.0 3032 2.5 2.7 13.5 0.81 658 7.6 3417 2.7 2.9 15.5 0.83 724 7.2 3850 2.6 2.6 16.5 0.82 731 7.1 3846 2.3 2.7 17 0.82 731 7.1 3846 2.3 2.7 17 0.82 819 7.4 4323 2.4 2.8 20.5 0.82 819 7.4 4323 2.4 2.8 20.5 0.83 891 7.2 4809 2.5 2.7 22 0.83 891 7.2 4809 2.5 2.7 22 0.85 984 7.4 5386 2.4 2.8 24 0.85 984 7.4 5386 2.4 2.8 24 0.84 1127 6.5 6053 1.1 2.5 31 0.85 1244 7.0 6814 1.3 2.5 37 0.84 1415 7.2 7677 1.3 2.7 41 Weight kg Sound pressure Level LPA dB 10 42 12 42 15 47 17 47 25 44 28 44 37 49 44 66 69 57 69 57 86 57 134 59 172 59 207 59 269 63 291 63 349 63 395 63 525 64 600 64 775 66 855 70 960 70 1000 70 1150 68 1520 75 1820 75 2180 75 2500 75 2600 75 2900 76 2900 76 3150 76 3150 76 3300 76 3300 76 3400 77 3400 77 4150 81 4500 81 4800 81 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 24 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1000 r/min = 6 poles 15 M3BP 160MLC 6 3GBP163430-··G 18.5 M3BP 180MLB 6 3GBP183420-··G 30 3) M3BP 200MLC 6 3GBP203430-··G 37 M3BP 225SMB 6 3GBP223220-··G 45 3) M3BP 225SMC 6 3GBP223230-··G 45 M3BP 250SMB 6 3GBP253220-··G 55 M3BP 250SMC 6 3GBP253230-··G 75 M3BP 280SMC 6 3GBP283230-··G 90 M3BP 280MLA 6 3GBP283410-··G 110 M3BP 280MLB 6 3GBP283420-··G 160 M3BP 315LKA 6 3GBP313810-··G 180 M3BP 315LKB 6 3GBP313820-··G 200 M3BP 315LKC 6 3GBP313830-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 971 89.7 90.5 90.2 975 90.7 92.0 92.0 985 92.0 93.1 92.8 985 93.1 94.0 94.0 984 92.7 93.3 93.3 989 93.4 94.1 93.9 988 93.2 93.7 93.6 990 94.2 94.7 94.5 990 94.1 94.3 93.7 990 94.5 94.8 94.4 992 95.3 95.3 94.7 992 95.3 95.4 94.8 989 95.4 95.6 95.3 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.77 31.3 7.3 147 1.8 3.6 0.131 0.79 37.2 5.8 181 1.7 2.7 0.198 0.83 56.7 6.9 290 2.3 2.8 0.531 0.83 69.1 6.6 358 2.3 2.6 0.821 0.83 84.4 6.4 436 2.3 2.6 0.821 0.83 83.7 7.0 434 2.5 2.7 1.37 0.84 101 7.1 531 2.6 2.8 1.5 0.84 137 7.3 723 2.8 2.7 2.85 0.81 170 7.1 868 2.4 2.5 3.1 0.82 205 7.5 1061 2.7 2.6 4.1 0.83 291 7.5 1540 2.6 2.8 7.3 0.83 328 7.4 1732 2.6 2.8 8.3 0.85 360 6.8 1931 2.5 2.6 9.2 Weight kg Sound pressure Level LPA dB 185 59 221 59 318 63 393 63 393 63 441 63 468 63 725 66 840 70 890 70 1410 74 1520 74 1600 74 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 ABB Motors and Generators | 9AKK105944 EN 02-2020 25 Technical data, 400 V 50 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 750 r/min = 8 poles 0.09 M3BP 71MA 8 3GBP074101-··B 0.12 M3BP 71MB 8 3GBP074102-··B 0.18 M3BP 80MA 8 3GBP084101-··B 0.25 M3BP 80MB 8 3GBP084102-··B 0.37 M3BP 90SLB 8 3GBP094102-··B 0.55 M3BP 90SLC 8 3GBP094103-··B 0.75 M3BP 100LA 8 3GBP104101-··B 1.1 M3BP 100LB 8 3GBP104102-··B 1.5 M3BP 112M 8 3GBP114101-··B 2.2 M3BP 132SMA 8 3GBP134101-··B 3 4) M3BP 132SMB 8 3GBP134102-··B 4 M3BP 160MLA 8 3GBP164410-··G 5.5 M3BP 160MLB 8 3GBP164420-··G 7.5 M3BP 160MLC 8 3GBP164430-··G 11 M3BP 180MLA 8 3GBP184410-··G 15 M3BP 200MLA 8 3GBP204410-··G 18.5 M3BP 225SMA 8 3GBP224210-··G 22 M3BP 225SMB 8 3GBP224220-··G 30 M3BP 250SMA 8 3GBP254210-··G 37 M3BP 280SMA 8 3GBP284210-··G 45 M3BP 280SMB 8 3GBP284220-··G 55 M3BP 315SMA 8 3GBP314210-··G 75 M3BP 315SMB 8 3GBP314220-··G 90 M3BP 315SMC 8 3GBP314230-··G 110 M3BP 315MLA 8 3GBP314410-··G 132 M3BP 355SMA 8 3GBP354210-··G 160 M3BP 355SMB 8 3GBP354220-··G 200 M3BP 355SMC 8 3GBP354230-··G 250 M3BP 355MLB 8 3GBP354420-··G 315 M3BP 400LA 8 3GBP404510-··G 315 M3BP 400LKA 8 3GBP404810-··G 315 3) M3BP 355LKB 8 3GBP354820-··G 355 M3BP 400LB 8 3GBP404520-··G 355 M3BP 400LKB 8 3GBP404820-··G 400 M3BP 400LC 8 3GBP404530-··G 400 M3BP 400LKC 8 3GBP404830-··G 450 M3BP 450LA 8 3GBP454510-··G 500 M3BP 450LB 8 3GBP454520-··G 560 M3BP 450LC 8 3GBP454530-··G 630 3) M3BP 450LD 8 3GBP454540-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 660 49.4 46.4 39.7 670 51.5 47.6 40.0 700 57.4 53.7 46.1 680 61.5 61.3 53.5 705 66.3 64.0 57.0 655 61.8 65.6 65.2 710 74.0 72.3 67.1 695 76.0 76.4 74.5 690 74.4 75.9 74.1 715 78.3 75.1 75.5 715 79.9 79.7 76.6 728 84.0 85.1 83.6 726 84.6 85.9 84.8 727 86.0 87.3 86.5 731 86.9 87.6 86.7 737 89.5 90.8 90.3 739 90.0 91.1 90.6 738 90.5 91.4 91.0 742 91.2 91.8 91.1 741 91.7 92.0 91.2 741 92.1 92.3 91.7 742 92.4 93.0 92.4 741 93.0 93.2 93.0 741 93.3 93.7 93.3 740 93.6 93.9 94.0 744 93.9 93.8 93.3 744 94.2 94.2 93.7 742 94.5 95.0 94.8 743 94.5 94.7 94.1 744 96.1 96.0 95.6 744 96.1 96.0 95.6 742 95.5 95.7 95.2 743 95.8 96.0 95.8 743 95.8 96.0 95.8 744 96.0 96.3 95.8 744 96.0 96.3 95.8 744 96.2 96.5 96.2 744 96.3 96.4 96.2 744 96.4 96.5 96.1 745 96.6 96.7 96.2 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.60 0.44 2.7 1.3 2.0 2.5 0.00089 0.56 0.6 2.7 1.7 2.0 2.5 0.0011 0.62 0.78 3.2 2.5 2.1 2.8 0.00187 0.65 0.94 3.1 3.5 1.9 2.6 0.00239 0.54 1.43 2.8 5 1.9 2.5 0.00444 0.67 1.92 2.6 8 1.4 1.9 0.00491 0.61 2.48 3.7 10.1 1.8 2.6 0.0072 0.66 3.12 3.6 15.1 1.6 2.3 0.00871 0.74 4.11 3.5 20.9 1.9 2.6 0.0106 0.66 6.51 4.7 29.2 1.6 2.8 0.0334 0.64 8.5 4.7 39.7 1.7 2.8 0.04 0.67 10.2 5.4 52.4 1.5 2.6 0.068 0.67 13.9 5.6 72.3 1.4 2.6 0.085 0.65 19.3 4.7 98.5 1.5 2.8 0.132 0.67 27.3 4.4 143 1.8 2.6 0.214 0.74 32.4 5.3 194 2.0 2.4 0.45 0.73 40.1 5.2 239 2.0 2.3 0.669 0.74 46.8 5.5 284 2.0 2.3 0.722 0.71 66 5.8 386 2.6 2.4 1.4 0.79 72.6 7.3 476 1.7 3.0 1.85 0.78 89.2 7.6 579 1.8 3.1 2.2 0.79 106 7.1 707 1.6 2.7 3.2 0.82 146 7.1 966 1.7 2.7 4.1 0.82 170 7.4 1159 1.8 2.7 4.9 0.83 211 7.3 1419 1.8 2.7 5.8 0.80 256 7.5 1694 1.5 2.6 7.9 0.77 293 7.6 2053 1.6 2.6 9.7 0.79 385 7.4 2576 1.6 2.6 11.3 0.80 472 7.5 3213 1.6 2.7 13.5 0.81 592 7.0 4043 1.2 2.6 17 0.81 592 7.0 4043 1.2 2.6 17 0.80 595 7.9 4053 1.7 2.7 16.5 0.83 641 6.8 4562 1.2 2.5 21 0.83 641 6.8 4562 1.2 2.5 21 0.82 735 6.0 5134 1.3 2.7 24 0.82 735 6.0 5134 1.3 2.7 24 0.83 813 6.0 5775 1.0 2.5 26 0.83 902 6.4 6417 1.0 2.6 29 0.82 1038 7.0 7188 1.2 2.9 35 0.81 1162 7.6 8075 1.3 3.2 41 Weight kg Sound pressure Level LPA dB 11 40 12 43 15 45 17 50 24 50 25 53 30 46 30 53 39 55 70 56 75 58 120 59 134 59 184 59 233 59 290 60 350 63 363 63 440 63 605 65 645 65 830 62 930 62 1000 64 1150 72 1520 69 1680 69 1820 69 2180 72 2900 71 2900 71 2600 75 3200 71 3200 71 3400 71 3400 71 3750 80 4000 80 4350 80 4800 80 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 26 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 750 r/min = 8 poles 18.5 M3BP 200MLB 8 3GBP204420-··G 30 M3BP 225SMC 8 3GBP224230-··G 37 M3BP 250SMB 8 3GBP254220-··G 45 3) M3BP 250SMC 8 3GBP254230-··G 55 M3BP 280SMC 8 3GBP284230-··G 75 M3BP 280MLB 8 3GBP284420-··G 132 M3BP 315LKA 8 3GBP314810-··G 150 3) M3BP 315LKB 8 3GBP314820-··G 160 3) M3BP 315LKC 8 3GBP314830-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 739 90.0 90.8 90.2 737 91.2 92.3 92.1 740 91.7 92.8 92.5 738 92.1 93.3 93.3 741 92.4 92.8 92.7 739 93.7 93.9 93.3 740 94.1 94.4 94.2 741 94.1 94.7 94.6 739 94.2 94.7 94.7 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.74 40 5.4 239 2.1 2.3 0.53 0.73 64.7 5.6 388 2.3 2.4 0.828 0.73 78.9 5.4 477 2.6 2.3 1.51 0.74 95.1 5.6 582 2.3 2.4 1.51 0.80 107 7.9 708 1.9 3.1 2.85 0.80 144 6.7 969 1.7 2.6 4.1 0.83 243 7.3 1703 1.8 2.6 7.3 0.83 278 7.7 1938 1.9 2.7 8.3 0.83 297 7.7 2068 1.9 2.8 9.2 Weight kg Sound pressure Level LPA dB 318 60 393 63 468 63 468 63 725 65 890 72 1410 74 1520 74 1600 74 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 ABB Motors and Generators | 9AKK105944 EN 02-2020 27 Technical data, 400 V 50 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 600 r/min = 10 poles 15 M3BP 200MLB 10 3GBP205420-··G 37 M3BP 280SMB 10 3GBP285220-··G 45 M3BP 280SMC 10 3GBP285230-··G 55 M3BP 315SMB 10 3GBP315220-··G 75 M3BP 315SMC 10 3GBP315230-··G 90 M3BP 315MLA 10 3GBP315410-··G 110 M3BP 355SMA 10 3GBP355210-··G 132 M3BP 355SMB 10 3GBP355220-··G 160 M3BP 355SMC 10 3GBP355230-··G 200 M3BP 355MLB 10 3GBP355420-··G 250 3) M3BP 355LKB 10 3GBP355820-··G 250 M3BP 400LB 10 3GBP405520-··G 315 M3BP 400LC 10 3GBP405530-··G 355 M3BP 450LA 10 3GBP455510-··G 400 M3BP 450LB 10 3GBP455520-··G 450 M3BP 450LC 10 3GBP455530-··G 500 3) M3BP 450LD 10 3GBP455540-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 587 88.2 88.4 86.9 593 92.5 92.3 90.9 592 93.0 92.9 91.7 594 93.8 93.8 92.9 593 93.6 93.7 92.8 593 93.7 93.8 93.0 595 94.5 94.5 93.6 594 94.8 94.9 94.2 594 94.8 94.9 94.2 594 95.0 95.1 94.5 593 95.1 95.3 94.8 595 95.3 95.3 94.5 595 95.4 95.4 94.7 596 95.9 95.9 95.2 596 95.9 95.9 95.1 596 96.1 96.1 95.4 596 96.1 96.1 95.4 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.71 34.5 5.3 244 1.7 2.4 0.54 0.73 79 6.6 595 1.6 3.0 2.2 0.75 93.1 6.7 725 1.6 2.8 2.85 0.78 108 6.7 884 1.6 2.7 4.1 0.78 148 6.6 1207 1.5 2.8 4.9 0.78 177 6.6 1449 1.7 2.7 5.8 0.76 221 6.6 1765 1.3 2.5 7.9 0.79 254 6.6 2122 1.3 2.4 9.7 0.77 316 6.9 2572 1.4 2.5 11.3 0.78 389 6.5 3215 1.4 2.4 13.5 0.78 486 6.3 4025 1.4 2.3 16.5 0.74 511 6.2 4012 1.3 2.3 20 0.74 644 6.2 5055 1.3 2.3 24 0.72 742 5.8 5687 1.1 2.2 31 0.72 836 5.7 6408 1.0 2.1 34 0.73 925 5.8 7210 1.0 2.1 38 0.71 1057 5.9 8011 1.1 2.2 42 Weight kg Sound pressure Level LPA dB 305 61 645 60 725 60 930 70 1000 70 1150 70 1520 73 1680 73 1820 76 2180 77 2600 79 3100 79 3400 79 4050 82 4250 82 4550 82 4800 82 Output kW Motor type Product code 500 r/min = 12 poles 30 M3BP 280SMB 12 3GBP286220-··G 37 M3BP 280SMC 12 3GBP286230-··G 45 M3BP 315SMB 12 3GBP316220-··G 55 M3BP 315SMC 12 3GBP316230-··G 75 M3BP 315MLA 12 3GBP316410-··G 90 M3BP 355SMA 12 3GBP356210-··G 110 M3BP 355SMB 12 3GBP356220-··G 132 M3BP 355SMC 12 3GBP356230-··G 160 M3BP 355MLB 12 3GBP356420-··G 200 3) M3BP 355LKB 12 3GBP356820-··G 200 M3BP 400LB 12 3GBP406520-··G 315 M3BP 450LB 12 3GBP456520-··G 400 3) M3BP 450LD 12 3GBP456540-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 493 90.2 89.5 493 90.6 89.8 494 92.8 92.9 493 93.0 93.2 493 93.2 93.4 495 93.5 93.5 495 93.8 93.8 495 93.9 93.9 494 93.8 94.0 494 93.9 94.1 495 95.0 95.0 496 95.6 95.6 495 95.7 95.8 86.9 87.2 92.0 92.4 92.8 92.5 92.7 92.9 93.3 93.4 94.3 94.8 95.2 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.59 81.3 5.8 581 1.9 3.0 2.2 0.58 101 6.3 716 2.0 3.2 2.85 0.76 92 6.5 869 1.6 2.6 4.1 0.77 110 6.5 1065 1.6 2.6 4.9 0.76 152 6.3 1452 1.5 2.5 5.8 0.72 192 5.7 1736 1.3 2.4 7.9 0.71 238 6.0 2122 1.4 2.5 9.7 0.71 285 6.0 2546 1.4 2.5 11.3 0.74 332 5.7 3092 1.3 2.4 13.5 0.73 421 5.8 3866 1.4 2.4 16.5 0.79 384 5.4 3858 1.1 2.2 20 0.76 625 5.5 6064 1.0 2.1 34 0.77 783 5.3 7716 1.0 2.0 42 Weight kg Sound pressure Level LPA dB 645 71 725 71 930 71 1000 71 1150 71 1520 75 1680 75 1820 77 2180 77 2600 79 3100 82 4300 82 4800 82 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 28 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 460 V 60 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3600 r/min = 2 poles 0.37 M3BP 71MA 2 3GBP071321-··B 0.55 M3BP 71MB 2 3GBP071322-··B 0.75 M3BP 80MB 2 3GBP081322-··B 1.1 M3BP 80MC 2 3GBP081323-··B 1.5 M3BP 90SLB 2 3GBP091322-··B 2.2 M3BP 90SLC 2 3GBP091323-··B 3 4) M3BP 100LB 2 3GBP101322-··B 4 4) M3BP 112MB 2 3GBP111322-··B 5.5 4) M3BP 132SMB 2 3GBP131322-··B 7.5 M3BP 132SMC 2 3GBP131324-··B 11 M3BP 160MLA 2 3GBP161410-··G 15 M3BP 160MLB 2 3GBP161420-··G 18.5 M3BP 160MLC 2 3GBP161430-··G 22 M3BP 180MLA 2 3GBP181410-··G 30 M3BP 200MLA 2 3GBP201410-··G 37 M3BP 200MLB 2 3GBP201420-··G 45 M3BP 225SMA 2 3GBP221210-··G 55 M3BP 250SMA 2 3GBP251210-··G 75 M3BP 280SMA 2 3GBP281210-··N 90 M3BP 280SMB 2 3GBP281220-··N 110 M3BP 315SA 2 3GBP311110-··N 132 M3BP 315SMA 2 3GBP311210-··N 160 M3BP 315SMB 2 3GBP311220-··N 200 1)4) M3BP 315MLA 2 3GBP311410-··G 250 1) M3BP 355SMA 2 3GBP351210-··G 315 1) M3BP 355SMB 2 3GBP351220-··G 355 1) M3BP 355SMC 2 3GBP351230-··G 400 1) M3BP 355MLA 2 3GBP351410-··G 450 1)3) M3BP 355MLB 2 3GBP351420-··G 500 1) M3BP 355LKA 2 3GBP351810-··G 560 1) M3BP 400LA 2 3GBP401510-··G 560 1) M3BP 400LKA 2 3GBP401810-··G 630 1) M3BP 400LB 2 3GBP401520-··G 630 1) M3BP 400LKB 2 3GBP401820-··G 710 1) M3BP 400LC 2 3GBP401530-··G 710 1) M3BP 400LKC 2 3GBP401830-··G 800 1)3) M3BP 450LA 2 3GBP451510-··G 900 1)3) M3BP 450LB 2 3GBP451520-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 3389 3439 3510 3490 3505 3500 3530 3510 3485 3505 3547 3545 3543 3559 3562 3564 3566 3571 3575 3574 3581 3579 3579 3582 3585 3582 3586 3582 3585 3584 3588 3588 3588 3588 3588 3588 3591 3591 460 V 60 Hz 76.7 76.4 79.4 81.1 80.3 78.3 82.9 81.8 84.4 84.0 85.5 85.5 87.0 85.7 85.0 84.4 86.0 85.3 89.5 89.1 90.9 91.0 90.9 91.2 91.6 92.1 91.6 91.6 92.3 92.0 92.9 92.7 93.5 93.2 93.5 93.2 93.6 93.2 94.5 94.3 94.5 94.1 95.0 94.6 95.0 94.8 95.1 94.7 95.5 95.0 95.6 95.3 95.7 95.3 96.4 95.9 96.2 95.8 96.2 95.9 96.2 95.8 96.2 95.8 96.2 96.0 96.2 96.0 96.2 96.0 96.2 96.0 96.2 95.9 96.2 95.9 73.2 79.9 73.6 78.4 81.6 83.5 82.4 82.1 82.8 86.8 89.8 90.0 91.3 90.3 90.4 91.0 91.7 91.7 91.5 93.3 92.6 93.3 93.9 93.5 93.6 94.1 94.2 94.7 94.8 95.0 94.5 94.5 95.9 95.9 95.2 95.2 94.7 95.1 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.80 0.78 5.5 1.03 2.6 2.9 0.00039 0.83 1.04 6.0 1.52 3.0 3.5 0.00051 0.72 1.62 9.1 2.04 4.9 5.2 0.001 0.80 2.12 7.5 3.0 4.3 5.5 0.0012 0.87 2.57 7.5 4.07 2.8 3.1 0.00254 0.88 3.58 7.9 5.98 1.7 2.9 0.0028 0.87 5.1 9.1 8.0 3.4 4.2 0.00528 0.89 6.6 9.5 10.84 3.2 3.8 0.00575 0.87 8.6 7.9 15.01 2.6 3.1 0.0128 0.88 12.1 8.3 20.48 2.5 4.4 0.0136 0.90 16.7 8.6 29.6 2.6 3.5 0.044 0.90 22.4 8.7 40.4 2.7 3.8 0.053 0.92 27.2 8.7 49.8 3.1 3.8 0.063 0.87 34.3 8.8 59 3.0 3.8 0.076 0.90 44.9 8.7 80.4 2.8 3.4 0.178 0.89 55.8 9.2 99.1 3.1 3.7 0.196 0.88 68.6 7.7 120 2.6 2.7 0.244 0.88 83.2 7.7 147 2.3 3.0 0.507 0.89 112 8.9 200 2.7 3.2 0.61 0.90 132 8.6 240 3.0 3.5 0.73 0.90 163 8.4 293 2.7 3.4 0.95 0.90 194 8.2 352 2.8 3.3 1.1 0.91 233 8.3 426 2.7 3.4 1.25 0.90 293 8.7 532 2.7 3.3 2.1 0.89 370 8.6 665 1.8 3.7 3 0.89 466 7.8 839 2.2 3.3 3.4 0.88 528 8.1 945 2.2 3.3 3.6 0.88 589 8.3 1066 2.3 3.2 4.1 0.90 650 8.9 1199 2.2 3.2 4.3 0.90 722 9.0 1332.26 2.4 4.3 4.8 0.89 818 9.0 1490 2.3 3.8 7.9 0.89 818 9.0 1490 2.3 3.8 7.9 0.89 916 8.6 1676 3.0 4.5 8.2 0.89 916 8.6 1676 3.0 4.5 8.2 0.90 1026 8.4 1890 2.9 4.0 9.3 0.90 1026 8.4 1890 2.9 4.0 9.3 0.87 1188 8.0 2127 1.3 3.5 12.2 0.85 1366 7.8 2393 1.5 3.4 13.5 Weight kg Sound pressure Level LPA dB 11 61 11 59 16 60 18 63 24 72 25 67 36 71 37 73 68 73 70 73 127 73 141 73 170 73 190 73 283 76 298 76 347 78 405 79 540 81 590 81 770 82 865 82 925 82 1190 83 1600 86 1680 86 1750 88 2000 88 2080 88 2320 88 2950 86 2950 86 3050 86 3050 86 3300 86 3300 86 4000 4200 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 ABB Motors and Generators | 9AKK105944 EN 02-2020 29 Technical data, 460 V 60 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3600 r/min = 2 poles 22 M3BP 160MLD 2 3GBP161440-··G 27 M3BP 160MLE 2 3GBP161450-··G 30 M3BP 180MLB 2 3GBP181420-··G 45 M3BP 200MLC 2 3GBP201430-··G 55 M3BP 200MLD 2 3GBP201440-··G 55 M3BP 225SMB 2 3GBP221220-··G 75 M3BP 225SMC 2 3GBP221230-··G 75 M3BP 250SMB 2 3GBP251220-··G 80 M3BP 225SMD 2 3GBP221240-··G 90 M3BP 250SMC 2 3GBP251230-··G 110 1)3) M3BP 280SMC 2 3GBP281230-··G 132 1)3) M3BP 280MLA 2 3GBP281410-··G 160 1)3) M3BP 280MLB 2 3GBP281420-··G 250 1)3)4) M3BP 315LKA 2 3GBP311810-··G 315 1)3)4) M3BP 315LKC 2 3GBP311830-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 460 V 60 Hz 3546 91.6 92.1 91.2 3546 92.3 92.8 92.1 3558 92.3 92.4 91.7 3563 93.4 93.3 92.2 3560 93.5 93.7 92.6 3567 93.5 93.3 91.8 3573 94.0 93.8 92.7 3575 94.0 93.9 92.8 3570 94.0 93.8 92.7 3575 94.9 94.8 93.6 3580 94.0 93.6 92.3 3579 95.0 94.8 93.7 3578 95.0 94.9 93.9 3582 95.2 94.9 93.8 3583 95.2 95.0 94.1 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 Weight kg Sound pressure Level LPA dB High-output design 0.91 32.8 9.3 59.2 3.4 4.1 0.063 170 73 0.90 40.4 9.1 72.8 3.3 3.9 0.072 184 73 0.89 45.4 9.2 80.5 3.1 3.8 0.092 208 73 0.88 68.7 9.2 120 3.2 3.7 0.196 298 76 0.89 82.2 9.0 147 3.1 3.7 0.217 314 76 0.89 82.6 7.5 147 2.5 2.8 0.274 369 78 0.86 116 8.7 200 3.3 3.4 0.309 396 78 0.89 111 8.6 200 2.9 3.4 0.583 451 79 0.88 120 8.4 213 3.1 3.2 0.329 410 78 0.89 133 8.6 240 2.7 3.4 0.644 487 79 0.90 163 8.9 292 2.5 3.3 1.15 725 82 0.90 193 8.5 351 2.6 3.3 1.4 840 83 0.91 230 8.6 426 2.9 3.3 1.55 890 83 0.89 371 8.7 666 2.9 3.2 2.65 1440 83 0.89 467 10.1 839 3.4 3.5 3.3 1630 83 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 30 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 460 V 60 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1800 r/min = 4 poles 0.25 M3BP 71MA 4 3GBP072321-··B 0.37 M3BP 71MB 4 3GBP072322-··B 0.55 M3BP 80MA 4 3GBP082321-··B 0.75 M3BP 80MD 4 3GBP082324-··B 1.1 M3BP 90SLB 4 3GBP092322-··B 1.5 M3BP 90SLD 4 3GBP092325-··B 2.2 M3BP 100LC 4 3GBP102323-··B 3 M3BP 100LD 4 3GBP102324-··B 4 M3BP 112MB 4 3GBP112322-··B 5.5 M3BP 132SMB 4 3GBP132322-··B 7.5 M3BP 132SMC 4 3GBP132323-··B 11 M3BP 160MLA 4 3GBP162410-··G 15 M3BP 160MLB 4 3GBP162420-··G 18.5 M3BP 180MLA 4 3GBP182410-··G 22 M3BP 180MLB 4 3GBP182420-··G 30 M3BP 200MLA 4 3GBP202410-··G 37 M3BP 225SMA 4 3GBP222210-··G 45 M3BP 225SMB 4 3GBP222220-··G 55 M3BP 250SMA 4 3GBP252210-··G 75 M3BP 280SMA 4 3GBP282210-··N 90 M3BP 280SMB 4 3GBP282220-··N 110 M3BP 315SA 4 3GBP312110-··N 132 M3BP 315SMA 4 3GBP312210-··N 160 M3BP 315SMB 4 3GBP312220-··N 200 M3BP 315MLA 4 3GBP312410-··G 250 M3BP 355SMA 4 3GBP352210-··G 315 M3BP 355SMB 4 3GBP352220-··G 355 M3BP 355SMC 4 3GBP352230-··G 400 M3BP 355SMC 4 3GBP352230-··G 450 M3BP 355MLA 4 3GBP352410-··G 500 M3BP 355MLB 4 3GBP352420-··G 500 M3BP 355LKA 4 3GBP352810-··G 560 3) M3BP 355LKB 4 3GBP352820-··G 560 M3BP 400LA 4 3GBP402510-··G 560 M3BP 400LKA 4 3GBP402810-··G 630 M3BP 400LB 4 3GBP402520-··G 630 M3BP 400LKB 4 3GBP402820-··G 710 3) M3BP 400LC 4 3GBP402530-··G 710 3) M3BP 400LKC 4 3GBP402830-··G 800 M3BP 450LA 4 3GBP452510-··G 900 M3BP 450LB 4 3GBP452520-··G 1000 M3BP 450LC 4 3GBP452530-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1705 1710 1701 1740 1740 1740 1755 1755 1745 1765 1760 1772 1775 1781 1780 1783 1782 1784 1782 1786 1784 1787 1785 1786 1787 1789 1789 1788 1787 1789 1790 1791 1791 1792 1792 1792 1792 1792 1792 1792 1792 1792 460 V 60 Hz 73.2 73.3 75.1 74.9 75.5 76.0 82.5 81.7 84.0 83.6 86.1 86.0 87.5 86.7 87.6 87.2 87.7 87.6 89.9 89.6 90.5 90.4 91.3 91.6 92.2 92.3 92.5 92.8 93.1 93.4 93.8 94.0 93.6 93.5 94.2 94.1 95.0 95.2 94.5 94.4 94.5 94.5 95.0 95.0 95.0 95.1 95.0 95.0 95.2 95.1 95.4 95.3 95.8 95.7 95.8 95.7 95.9 96.0 95.8 95.8 96.2 96.0 96.8 96.3 96.4 96.2 96.2 96.0 96.2 96.0 96.2 96.0 96.2 96.0 96.8 96.6 96.8 96.6 96.2 95.9 96.8 96.3 96.8 96.6 70.5 71.9 72.3 78.5 81.0 84.0 84.3 85.0 86.0 87.5 88.8 90.5 91.5 92.0 92.5 93.1 92.4 93.0 94.7 93.4 93.8 94.4 94.5 94.3 94.3 94.4 94.8 94.9 95.6 95.0 95.3 95.2 95.6 95.3 95.3 95.4 95.4 96.0 96.0 95.3 96.0 95.8 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.76 0.56 4.3 1.42 2.3 2.6 0.00074 0.78 0.77 5.5 2.05 1.9 2.7 0.00088 0.70 1.39 6.1 3.01 2.4 3.6 0.00144 0.69 1.64 7.4 4.12 3.6 3.9 0.002 0.77 2.11 7.5 6.0 2.7 4.0 0.0044 0.81 2.74 7.8 8.2 3.0 4.1 0.0053 0.78 4.08 9.0 12 3.0 4.8 0.00948 0.78 5.42 9.1 16.35 3.2 4.1 0.011 0.82 6.94 8.2 21.96 2.8 3.4 0.0125 0.79 9.64 7.6 29.8 2.4 3.6 0.0328 0.82 12.7 8.2 40.88 2.7 4.1 0.0366 0.83 18.2 7.7 59.2 2.4 3.2 0.081 0.83 24.6 8.0 80.6 2.7 3.3 0.099 0.83 30.2 8.2 99.1 2.8 3.2 0.166 0.83 35.7 8.3 118 2.8 3.3 0.195 0.83 48.3 8.4 160 3.0 3.3 0.309 0.84 59 8.1 198 2.8 3.2 0.356 0.85 70.5 8.6 240 2.7 3.3 0.44 0.84 86.3 8.0 294 2.8 3.3 0.765 0.83 119 8.9 401 3.8 3.7 0.91 0.84 141 8.7 482 3.3 3.8 1.13 0.85 170 7.6 588 2.9 3.1 1.5 0.87 199 7.4 706 2.7 3.0 2 0.85 246 7.8 856 2.9 3.2 2.2 0.86 307 8.2 1068 2.7 3.2 3.5 0.85 388 8.0 1334 2.4 3.0 5.9 0.86 481 8.3 1680 2.4 3.1 6.9 0.87 536 7.8 1894 2.5 3.0 7.2 0.87 601 6.9 2137 2.2 2.7 7.2 0.86 683 7.0 2402 2.2 2.6 8.4 0.86 755 7.3 2667 2.3 3.0 8.4 0.85 763 8.0 2666 2.4 3.4 10 0.85 858 8.5 2988 2.8 2.9 10.6 0.84 863 7.8 2985 2.7 3.1 15 0.84 863 7.8 2985 2.7 3.1 15 0.85 959 8.9 3358 2.2 3.3 16 0.85 959 8.9 3358 2.2 3.3 16 0.84 1091 7.9 3784 2.5 3.3 17 0.84 1091 7.9 3784 2.5 3.3 17 0.86 1256 6.5 4263 1.3 3.1 23 0.85 1373 7.9 4794 1.3 3.1 25 0.86 1505 7.2 5329 1.4 2.8 30 Weight kg Sound pressure Level LPA dB 10 48 11 48 15 48 17 53 25 53 27 59 36 59 38 61 44 62 70 70 73 67 135 66 165 66 205 66 222 66 291 67 324 70 356 70 414 71 540 74 610 74 740 73 900 73 940 73 1160 74 1610 79 1780 74 1820 78 1820 83 2140 83 2140 83 2500 83 2600 83 3200 83 3200 83 3300 83 3300 83 3400 83 3400 83 4050 89 4350 89 4700 89 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 ABB Motors and Generators | 9AKK105944 EN 02-2020 31 Technical data, 460 V 60 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1800 r/min = 4 poles 18.5 M3BP 160MLC 4 3GBP162430-··G 22 M3BP 160MLD 4 3GBP162440-··G 30 M3BP 180MLC 4 3GBP182430-··G 37 M3BP 200MLB 4 3GBP202420-··G 45 M3BP 200MLC 4 3GBP202430-··G 55 M3BP 225SMC 4 3GBP222230-··G 64 M3BP 225SMD 4 3GBP222240-··G 75 M3BP 250SMB 4 3GBP252220-··G 90 M3BP 250SMC 4 3GBP252230-··G 110 M3BP 280SMC 4 3GBP282230-··G 132 M3BP 280MLA 4 3GBP282410-··G 160 M3BP 280MLB 4 3GBP282420-··G 250 4) M3BP 315LKA 4 3GBP312810-··G 315 4) M3BP 315LKC 4 3GBP312830-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1774 1770 1777 1783 1783 1782 1783 1782 1776 1786 1785 1785 1788 1789 460 V 60 Hz 92.4 92.7 92.5 93.2 93.2 93.6 94.2 94.5 94.4 94.5 94.4 94.5 94.4 94.4 94.8 95.0 95.2 95.3 95.2 95.2 95.3 95.3 95.6 95.6 95.3 95.1 95.3 95.1 92.1 92.6 93.0 94.1 93.9 93.8 93.4 94.4 94.6 94.3 94.4 95.0 94.1 94.1 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.83 30.2 8.7 99.5 3.3 3.6 0.11 0.84 35.4 7.8 118 2.7 3.3 0.125 0.83 48.6 8.3 161 2.9 3.3 0.217 0.84 58.6 8.5 198 2.8 3.3 0.343 0.83 72 8.6 241 3.2 3.6 0.366 0.85 86 8.5 294 3.1 3.4 0.474 0.85 100 9.4 342 3.5 3.7 0.542 0.85 116 8.4 401 3.1 3.5 0.866 0.84 141 8.6 483 3.5 3.7 0.941 0.86 169 8.7 587 3.2 3.3 1.85 0.86 202 8.1 705 2.9 3.1 2.3 0.85 247 7.3 855 3.1 3.2 2.5 0.85 389 8.4 1334 2.7 3.2 4.4 0.85 490 9.0 1680 2.9 3.6 5.5 Weight kg Sound pressure Level LPA dB 173 66 187 66 235 66 307 67 319 67 370 70 399 70 450 71 478 71 725 72 840 77 890 77 1410 82 1600 82 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 32 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 460 V 60 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1200 r/min = 6 poles 0.18 M3BP 71MA 6 3GBP073321-··B 0.25 M3BP 71MB 6 3GBP073322-··B 0.37 M3BP 80MA 6 3GBP083321-··B 0.55 M3BP 80MB 6 3GBP083322-··B 0.75 M3BP 90SLC 6 3GBP093323-··B 1.1 4) M3BP 90SLE 6 3GBP093324-··B 1.5 4) M3BP 100L 6 3GBP103322-··B 2.2 4) M3BP 112MB 6 3GBP113322-··B 3 4) M3BP 132SMB 6 3GBP133321-··B 4 4) M3BP 132SMC 6 3GBP133322-··B 5.5 4) M3BP 132SMF 6 3GBP133324-··B 7.5 M3BP 160MLA 6 3GBP163410-··G 11 M3BP 160MLB 6 3GBP163420-··G 15 M3BP 180MLA 6 3GBP183410-··G 18.5 M3BP 200MLA 6 3GBP203410-··G 22 M3BP 200MLB 6 3GBP203420-··G 30 M3BP 225SMA 6 3GBP223210-··G 37 M3BP 250SMA 6 3GBP253210-··G 45 M3BP 280SMA 6 3GBP283210-··N 55 M3BP 280SMB 6 3GBP283220-··N 75 M3BP 315SA 6 3GBP313110-··N 90 M3BP 315SMA 6 3GBP313210-··N 110 M3BP 315SMB 6 3GBP313220-··N 132 M3BP 315MLA 6 3GBP313410-··G 160 M3BP 355SMA 6 3GBP353210-··G 200 M3BP 355SMB 6 3GBP353220-··G 250 M3BP 355SMC 6 3GBP353230-··G 315 M3BP 355MLB 6 3GBP353420-··G 355 M3BP 355LKA 6 3GBP353810-··G 400 M3BP 400LA 6 3GBP403510-··G 400 M3BP 400LKA 6 3GBP403810-··G 400 M3BP 355LKB 6 3GBP353820-··G 450 M3BP 400LB 6 3GBP403520-··G 450 M3BP 400LKB 6 3GBP403820-··G 500 M3BP 400LC 6 3GBP403530-··G 500 M3BP 400LKC 6 3GBP403830-··G 560 M3BP 400LD 6 3GBP403540-··G 560 M3BP 400LKD 6 3GBP403840-··G 630 M3BP 450LA 6 3GBP453510-··G 710 M3BP 450LA 6 3GBP453510-··G 710 M3BP 450LB 6 3GBP453520-··G 800 M3BP 450LB 6 3GBP453520-··G 800 3) M3BP 450LC 6 3GBP453530-··G 900 3) M3BP 450LC 6 3GBP453530-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1120 1125 1135 1135 1160 1140 1160 1160 1180 1165 1165 1179 1177 1181 1190 1189 1189 1191 1191 1192 1191 1191 1191 1192 1194 1194 1194 1193 1193 1194 1194 1193 1194 1194 1194 1194 1194 1194 1195 1194 1196 1194 1195 1195 460 V 60 Hz 69.0 68.2 72.6 71.3 74.5 73.7 71.2 70.8 80.4 78.2 81.2 81.0 82.4 82.0 84.8 84.4 86.3 84.8 86.8 86.3 87.4 86.8 89.6 90.0 90.4 91.0 91.3 91.7 92.2 92.2 92.7 93.1 93.2 93.4 93.6 93.8 93.6 93.5 93.6 93.5 94.1 94.2 94.1 94.1 95.0 94.9 95.1 95.1 95.0 94.9 95.0 94.9 95.3 95.2 95.9 95.7 95.8 95.5 95.8 95.6 95.8 95.6 95.7 95.5 95.8 95.5 95.8 95.5 95.8 95.6 95.8 95.6 95.8 95.6 95.8 95.6 96.5 96.3 96.5 96.5 96.5 96.3 96.5 96.5 96.5 98.6 96.5 96.5 63.6 66.0 69.3 65.5 73.0 78.0 79.4 81.9 81.0 84.0 84.5 88.9 90.0 90.8 91.2 92.2 92.4 93.1 92.5 93.1 93.5 93.0 94.1 94.3 93.9 94.0 94.3 94.8 94.6 94.8 94.8 94.6 94.7 94.7 94.9 94.9 94.9 94.9 95.6 95.9 95.7 95.8 95.5 95.9 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.62 0.52 3.8 1.53 2.5 2.7 0.0009 0.62 0.68 4.4 2.1 3.1 3.4 0.0011 0.64 0.97 4.9 3.1 2.8 3.1 0.0019 0.66 1.34 4.5 4.6 2.1 2.8 0.00239 0.54 2.1 5.1 6.1 2.7 3.7 0.0049 0.65 2.6 4.6 9.2 2.3 2.9 0.0054 0.68 3.31 4.9 12.4 1.6 3.2 0.00873 0.68 4.89 5.0 18.19 1.8 2.7 0.0125 0.62 7.2 6.2 24.36 1.9 3.4 0.0334 0.70 8.58 5.6 32.81 2.3 3.0 0.0334 0.70 11.2 5.7 44.97 2.1 2.7 0.0487 0.77 13.6 7.4 60.7 1.7 3.2 0.087 0.77 19.8 8.4 89.2 2.0 3.4 0.114 0.74 27.8 6.5 121 1.9 3.1 0.168 0.79 31.8 7.5 148 2.5 3.2 0.382 0.81 36.7 7.5 176 2.5 3.2 0.448 0.82 49.2 8.0 240 2.8 3.2 0.663 0.81 61.2 7.6 296 2.6 3.0 1.13 0.81 74.5 7.8 361 2.9 3.0 1.36 0.81 89.9 8.5 440 3.5 3.8 1.8 0.83 121 7.8 601 2.9 2.9 2.6 0.82 146 7.7 721 3.0 3.3 2.8 0.82 178 8.3 882 3.0 3.2 3.5 0.82 211 8.6 1057 3.0 3.3 5.8 0.83 255 7.9 1279 2.2 2.9 7.9 0.83 319 8.2 1599 3.1 3.3 9.7 0.82 403 8.5 1999 2.9 3.2 11.3 0.82 499 8.0 2521 2.8 3.0 13.5 0.80 579 8.7 2842 3.0 3.2 15.5 0.82 637 8.2 3200 2.4 3.0 17 0.82 637 8.2 3200 2.4 3.0 17 0.82 639 7.5 3204 2.7 2.7 16.5 0.82 713 7.9 3598 2.5 3.1 20.5 0.82 713 7.9 3598 2.5 3.1 20.5 0.84 777 8.1 4000 2.6 3.0 22 0.84 777 8.1 4000 2.6 3.0 22 0.85 856 7.8 4481 2.4 3.2 24 0.85 856 7.8 4481 2.4 3.2 24 0.84 978 6.8 5036 1.1 2.9 31 0.84 1099 6.5 5678 1.0 2.4 31 0.85 1085 8.2 5671 1.4 2.9 37 0.85 1221 7.0 6398 1.2 2.5 37 0.84 1235 8.4 6389 1.3 3.1 41 0.84 1392 7.2 7191 1.2 2.7 41 Weight kg Sound pressure Level LPA dB 10 45 12 45 15 49 17 49 25 46 28 47 37 52 44 69 69 60 69 60 86 60 134 63 172 63 207 63 269 67 291 67 349 67 395 67 525 68 600 68 775 70 855 76 960 76 1150 72 1520 80 1680 80 1820 80 2180 80 2500 80 2900 79 2900 79 2600 80 3150 79 3150 79 3300 79 3300 79 3400 79 3400 79 4150 85 4150 85 4500 85 4500 85 4800 85 4800 85 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 ABB Motors and Generators | 9AKK105944 EN 02-2020 33 Technical data, 460 V 60 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1200 r/min = 6 poles 15 M3BP 160MLC 6 3GBP163430-··G 18.5 M3BP 180MLB 6 3GBP183420-··G 30 M3BP 200MLC 6 3GBP203430-··G 37 M3BP 225SMB 6 3GBP223220-··G 45 M3BP 225SMC 6 3GBP223230-··G 45 M3BP 250SMB 6 3GBP253220-··G 55 M3BP 250SMC 6 3GBP253230-··G 75 4) M3BP 280SMC 6 3GBP283230-··G 90 4) M3BP 280MLA 6 3GBP283410-··G 110 4) M3BP 280MLB 6 3GBP283420-··G 160 M3BP 315LKA 6 3GBP313810-··G 180 M3BP 315LKC 6 3GBP313820-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1176 1180 1188 1188 1187 1191 1189 1191 1191 1191 1193 1189 460 V 60 Hz 90.7 91.3 92.0 92.5 93.0 93.3 93.8 94.1 93.6 94.1 93.9 94.2 94.0 94.3 93.2 93.3 93.6 93.5 94.1 94.0 95.0 94.9 95.2 95.3 90.5 91.8 92.5 93.5 93.6 93.5 93.7 92.4 92.4 92.9 93.9 94.6 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.75 27.6 8.1 121 1.9 4.1 0.131 0.78 32.3 6.6 149 1.9 3.0 0.198 0.83 48.7 8.0 241 2.6 3.2 0.531 0.83 59.6 7.5 297 2.5 3.0 0.821 0.82 73.5 7.3 362 2.5 2.9 0.821 0.82 73.3 7.9 360 2.7 3.1 1.37 0.83 88.4 8.1 441 2.9 3.1 1.5 0.84 120 8.4 600 3.1 3.0 2.85 0.81 148 8.2 721 2.6 2.8 3.1 0.82 179 8.7 881 3.0 2.9 4.1 0.82 257 8.6 1280 2.9 3.1 7.3 0.83 316 7.8 1604 2.8 2.9 9.2 Weight kg Sound pressure Level LPA dB 185 63 221 63 318 67 393 67 393 67 441 67 468 67 725 70 840 76 890 76 1410 78 1600 78 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 34 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 460 V 60 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 900 r/min = 8 poles 0.09 M3BP 71MA 8 3GBP074101-··B 0.12 M3BP 71MB 8 3GBP074102-··B 0.18 M3BP 80MA 8 3GBP084101-··B 0.25 M3BP 80MB 8 3GBP084102-··B 0.37 M3BP 90SLB 8 3GBP094102-··B 0.55 M3BP 90SLC 8 3GBP094103-··B 0.75 M3BP 100LA 8 3GBP104101-··B 1.1 M3BP 100LB 8 3GBP104102-··B 1.5 4) M3BP 112M 8 3GBP114101-··B 2.2 4) M3BP 132SMA 8 3GBP134101-··B 3 4) M3BP 132SMB 8 3GBP134102-··B 4 M3BP 160MLA 8 3GBP164410-··G 5.5 M3BP 160MLB 8 3GBP164420-··G 7.5 4) M3BP 160MLC 8 3GBP164430-··G 11 M3BP 180MLA 8 3GBP184410-··G 15 M3BP 200MLA 8 3GBP204410-··G 18.5 M3BP 225SMA 8 3GBP224210-··G 22 M3BP 225SMB 8 3GBP224220-··G 30 M3BP 250SMA 8 3GBP254210-··G 37 M3BP 280SMA 8 3GBP284210-··G 45 M3BP 280SMB 8 3GBP284220-··G 55 M3BP 315SMA 8 3GBP314210-··G 75 M3BP 315SMB 8 3GBP314220-··G 90 M3BP 315SMC 8 3GBP314230-··G 110 M3BP 315MLA 8 3GBP314410-··G 132 M3BP 355SMA 8 3GBP354210-··G 160 M3BP 355SMB 8 3GBP354220-··G 200 M3BP 355SMC 8 3GBP354230-··G 250 M3BP 355MLB 8 3GBP354420-··G 315 M3BP 400LA 8 3GBP404510-··G 315 M3BP 400LKA 8 3GBP404810-··G 315 3) M3BP 355LKB 8 3GBP354820-··G 355 M3BP 400LB 8 3GBP404520-··G 355 M3BP 400LKB 8 3GBP404820-··G 400 M3BP 400LC 8 3GBP404530-··G 400 M3BP 400LKC 8 3GBP404830-··G 450 3) M3BP 400LC 8 3GBP404530-··G 450 3) M3BP 400LKC 8 3GBP404830-··G 560 M3BP 450LC 8 3GBP454530-··G 630 3) M3BP 450LD 8 3GBP454540-··G 710 3) M3BP 450LD 8 3GBP454540-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 460 V 60 Hz 835 53.0 49.4 42.1 840 54.9 49.9 41.5 860 58.9 55.9 49.2 845 64.2 61.8 55.7 860 69.1 66.0 58.1 825 68.1 67.6 62.8 865 77.1 75.5 70.8 855 79.7 79.0 75.5 850 79.2 79.1 76.3 870 80.8 79.6 76.1 870 83.2 82.0 78.4 882 85.8 85.7 83.4 881 86.4 86.6 84.6 882 87.7 87.8 86.2 885 88.6 89.2 87.8 890 90.1 90.5 89.4 890 90.1 90.4 89.0 890 91.6 91.9 90.8 893 91.6 91.6 90.3 893 92.3 92.1 90.6 892 92.3 92.1 90.6 893 93.0 92.8 91.6 892 93.4 93.4 92.4 892 93.9 93.9 93.0 891 93.6 93.7 93.0 895 94.4 94.2 92.9 895 94.4 94.2 92.9 893 94.9 94.8 93.9 893 94.9 94.8 94.0 894 95.5 95.5 94.9 894 95.5 95.5 94.9 893 95.5 95.5 94.7 894 96.3 96.4 95.9 894 96.3 96.4 95.9 895 95.9 96.0 95.3 895 95.9 96.0 95.3 894 96.2 96.2 95.7 894 96.2 96.2 95.7 894 96.1 96.1 95.5 896 96.9 96.8 96.1 895 96.5 96.5 95.9 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.59 0.36 2.4 1.02 2.6 2.8 0.00089 0.49 0.57 3.1 1.35 2.5 3.2 0.0011 0.55 0.74 3.5 2.0 2.4 3.5 0.00187 0.58 0.88 3.5 2.85 2.2 3.2 0.00239 0.51 1.38 3.3 4.1 2.0 2.9 0.00444 0.62 1.7 3.0 6.45 1.6 2.3 0.00491 0.56 2.3 4.1 8.25 2.0 3.2 0.0072 0.61 2.84 4.0 12.2 1.8 2.8 0.00871 0.67 3.64 4.1 16.9 2.1 2.7 0.0106 0.63 5.93 5.2 24.1 1.7 3.2 0.0334 0.63 7.7 5.2 32.75 1.8 3.3 0.04 0.64 9.1 5.9 43.3 1.6 3.0 0.068 0.65 12.2 6.2 59.6 1.5 3.0 0.085 0.63 17 5.1 81.2 1.5 3.2 0.132 0.66 23.5 5.1 118 2.0 2.9 0.214 0.71 28.5 5.9 160 2.3 2.7 0.45 0.72 35 5.9 198 2.2 2.5 0.669 0.73 40.8 6.3 236 2.2 2.6 0.722 0.70 57.8 6.6 320 2.8 2.7 1.4 0.78 64 8.1 395 1.8 3.4 1.85 0.77 79 8.4 481 1.9 3.5 2.2 0.79 93.9 7.8 587 1.7 3.0 3.2 0.78 128 7.9 802 1.8 3.0 4.1 0.80 149 8.2 962 1.9 3.0 4.9 0.79 186 8.1 1178 1.9 3.0 5.8 0.76 230 8.3 1409 1.5 2.9 7.9 0.77 274 8.4 1703 1.6 2.8 9.7 0.79 335 8.2 2143 1.6 2.9 11.3 0.79 417 8.3 2672 1.6 2.9 13.5 0.80 520 7.0 3362 1.2 2.9 17 0.80 520 7.0 3362 1.2 2.9 17 0.79 524 8.8 3369 1.8 2.9 16.5 0.82 564 8.4 3793 1.2 2.8 21 0.82 564 8.4 3793 1.2 2.8 21 0.81 647 6.4 4273 1.3 3.0 24 0.81 647 6.4 4273 1.3 3.0 24 0.82 715 7.3 4806 1.2 2.5 24 0.82 715 7.3 4806 1.2 2.5 24 0.81 907 6.5 5979 1.4 3.1 35 0.81 1013 8.6 6717 1.5 3.4 41 0.82 1126 7.7 7575 1.2 3.2 41 Weight kg Sound pressure Level LPA dB 11 43 12 46 15 48 17 53 24 53 25 56 30 49 30 56 39 58 70 59 75 61 120 63 134 63 184 63 233 63 290 64 350 67 363 67 440 67 605 68 645 69 830 62 930 62 1000 64 1150 76 1520 72 1680 72 1820 72 2180 75 2900 73 2900 73 2600 78 3200 73 3200 73 3400 73 3400 73 3400 73 3400 73 4350 80 4800 80 4800 80 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 ABB Motors and Generators | 9AKK105944 EN 02-2020 35 Technical data, 460 V 60 Hz IE2 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 900 r/min = 8 poles 18.5 M3BP 200MLB 8 3GBP204420-··G 30 M3BP 225SMC 8 3GBP224230-··G 37 M3BP 250SMB 8 3GBP254220-··G 45 M3BP 250SMC 8 3GBP254230-··G 55 M3BP 280SMC 8 3GBP284230-··G 75 M3BP 280MLB 8 3GBP284420-··G 132 M3BP 315LKA 8 3GBP314810-··G 150 3) M3BP 315LKB 8 3GBP314820-··G 160 M3BP 315LKC 8 3GBP314830-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 460 V 60 Hz 891 90.1 90.4 889 91.6 91.9 891 92.3 92.7 891 92.3 92.9 892 93.2 93.1 890 93.4 93.4 891 94.1 94.2 892 94.1 94.1 890 93.9 94.0 89.0 91.1 92.0 92.3 92.0 92.4 93.6 93.6 93.3 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.72 35.3 6.1 198 2.3 2.6 0.53 0.72 56.3 6.4 322 2.6 2.7 0.828 0.72 68.9 6.1 396 2.8 2.6 1.51 0.74 81.7 6.4 482 2.5 2.7 1.51 0.78 95.2 8.8 588 2.0 3.5 2.85 0.79 126 7.4 804 1.8 2.9 4.1 0.82 214 8.1 1414 1.9 2.9 7.3 0.82 244 8.6 1609 2.0 3.0 8.3 0.82 261 8.5 1717 2.0 3.1 9.2 Weight kg Sound pressure Level LPA dB 318 64 393 67 468 67 468 67 725 69 890 75 1410 78 1520 78 1600 78 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 36 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3000 r/min = 2 poles 0.75 M3BP 80MD 2 3GBP081340-··K 1.1 M3BP 80MG 2 3GBP081370-··K 1.5 M3BP 90LB 2 3GBP091520-··K 2.2 M3BP 90LC 2 3GBP091530-··K 3 M3BP 100LKA 2 3GBP101810-··K 4 M3BP 112MG 2 3GBP111370-··K 5.5 M3BP 132SMF 2 3GBP131260-··K 7.5 M3BP 132SMG 2 3GBP131270-··K 11 M3BP 160MLA 2 3GBP161410-··K 18.5 M3BP 160MLC 2 3GBP161430-··K 22 M3BP 180MLA 2 3GBP181410-··K 30 M3BP 200MLA 2 3GBP201410-··K 37 M3BP 200MLB 2 3GBP201420-··K 45 M3BP 225SMA 2 3GBP221210-··K 55 M3BP 250SMA 2 3GBP251210-··K 75 M3BP 280SMB 2 3GBP281220-··K 90 M3BP 280SMC 2 3GBP281230-··K 110 M3BP 315SMB 2 3GBP311220-··K 132 M3BP 315SMC 2 3GBP311230-··K 160 M3BP 315MLA 2 3GBP311410-··K 200 1) M3BP 355SMA 2 3GBP351210-··K 250 1) M3BP 355SMB 2 3GBP351220-··K 315 1) M3BP 355SMC 2 3GBP351230-··K 355 1) M3BP 355MLA 2 3GBP351410-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 2894 2883 2906 2900 2896 2888 2901 2909 2943 2949 2956 2956 2959 2968 2968 2978 2981 2982 2986 2983 2985 2984 2980 2984 400 V 50 Hz 80.7 80.4 82.7 82.4 84.2 84.7 85.9 87.5 87.1 88.2 88.1 89.4 89.2 89.9 90.1 91.2 91.2 92.0 92.4 93.0 92.7 93.1 93.3 93.7 93.7 93.9 94.0 94.0 94.3 93.7 94.7 94.4 95.7 95.6 95.9 95.9 96.1 96.2 95.6 95.6 96.4 96.1 95.8 95.5 95.8 95.7 95.8 95.8 77.2 80.6 84.6 87.6 88.0 89.6 90.1 91.4 91.6 92.6 92.7 93.0 93.2 93.0 93.6 93.5 95.0 95.2 95.9 94.9 95.3 94.5 95.0 94.9 Current Power factor IN Cosj A IS/IN B design 0.74 1.7 7.9 0.81 2.3 7.9 0.89 2.8 7.9 0.89 4.0 8.3 0.90 5.4 8.4 0.91 7.1 8.4 0.91 9.7 7.9 0.90 13.1 8.3 0.91 19.1 7.2 0.90 32 9.0 0.90 37.7 7.8 0.90 51.6 7.7 0.90 63.5 8.2 0.87 79.6 7.3 0.89 94.8 6.8 0.88 130 7.0 0.88 153 8.0 0.88 189 6.7 0.88 226 7.9 0.87 275 7.4 0.89 336 7.6 0.89 423 7.7 0.89 531 7.0 0.88 603 7.2 Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 2.4 3.7 4.2 0.0008 3.6 3.7 4.2 0.001 4.9 2.3 3.3 0.0027 7.2 2.9 3.5 0.0032 9.8 3.2 3.9 0.0057 13.2 3.2 4.0 0.0104 18.1 2.3 3.4 0.0154 24.6 3.0 3.9 0.0173 35.57 2.6 3.6 0.057 59.81 3.3 3.9 0.076 70.98 3.0 3.8 0.11 96.9 2.7 3.1 0.178 119 3.0 3.3 0.196 145 3.2 3.1 0.296 177 2.4 3.0 0.426 240 2.3 3.0 0.9 288 3.0 3.1 1.15 352 1.9 2.6 1.4 422 2.4 3.0 1.7 512 2.2 2.8 1.7 640 2.0 3.1 3 800 2.1 3.3 3 1009 2.1 3.0 3.4 1136 2.2 3.0 3.6 Weight kg Sound pressure Level LPA dB 18 57 19 56 31 60 35 60 50 62 56 68 77 68 77 70 141 69 183 73 234 73 289 72 314 72 409 76 452 76 665 74 725 77 940 77 1025 77 1190 78 1600 83 1680 83 1750 83 2000 83 Output kW Motor type Product code 3000 r/min = 2 poles 200 M3BP 315MLB 2 250 M3BP 315LKB 2 3GBP311420-··K 3GBP311820-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 2983 95.8 95.8 95.3 2982 96.4 96.7 96.7 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.88 342 7.7 640 2.5 3.1 2.1 0.91 413 7.9 800 2.5 2.7 2.9 Weight kg Sound pressure Level LPA dB 1220 81 1540 77 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. ABB Motors and Generators | 9AKK105944 EN 02-2020 37 Technical data, 400 V 50 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1500 r/min = 4 poles 0.75 M3BP 90L 4 3GBP092500-··K 0.75 M3BP 80MLG 4 3GBP082470-··K 0.75 M3BP 80MLG 4 3GBP082470-··K 1.1 M3BP 90LC 4 3GBP092530-··K 1.5 M3BP 90LD 4 3GBP092540-··K 2.2 M3BP 100LKA 4 3GBP102810-··K 3 M3BP 100LKB 4 3GBP102820-··K 4 M3BP 112MG 4 3GBP112370-··K 5.5 M3BP 132SMF 4 3GBP132260-··K 7.5 M3BP 132SMG 4 3GBP132270-··K 11 M3BP 160MLA 4 3GBP162410-··K 15 M3BP 160MLB 4 3GBP162420-··K 18.5 M3BP 180MLA 4 3GBP182410-··K 22 M3BP 180MLB 4 3GBP182420-··K 30 M3BP 200MLA 4 3GBP202410-··K 37 M3BP 225SMA 4 3GBP222210-··K 45 M3BP 225SMB 4 3GBP222220-··K 55 M3BP 250SMA 4 3GBP252210-··K 75 M3BP 280SMB 4 3GBP282220-··K 90 M3BP 280SMC 4 3GBP282230-··K 110 M3BP 315SMC 4 3GBP312230-··K 132 M3BP 315SMD 4 3GBP312240-··K 160 M3BP 315MLB 4 3GBP312420-··K 200 M3BP 355SMA 4 3GBP352210-··K 250 M3BP 355SMB 4 3GBP352220-··K 315 M3BP 355SMC 4 3GBP352230-··K 355 M3BP 355MLA 4 3GBP352410-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1448 1440 1449 1442 1439 1454 1452 1454 1463 1464 1477 1477 1481 1480 1483 1482 1482 1485 1485 1485 1491 1490 1490 1491 1491 1491 1490 400 V 50 Hz 85.3 85.7 82.5 82.4 84.1 85.0 84.1 83.5 85.3 84.7 86.7 87.2 87.7 88.1 88.6 89.1 89.6 89.8 90.4 90.8 91.4 91.8 92.1 92.4 92.6 93.2 93.3 94.1 93.6 93.9 93.9 94.1 94.2 94.4 95.4 95.9 95.0 95.2 95.2 95.5 96.2 96.5 96.3 96.6 96.5 96.7 96.6 96.7 96.0 96.0 96.0 96.1 96.0 96.2 84.4 80.2 83.8 81.7 82.8 86.1 87.1 88.6 88.7 90.7 91.1 91.6 92.9 94.1 93.4 93.8 94.0 95.7 94.8 95.2 96.1 96.2 96.4 96.4 95.6 95.7 95.8 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.78 1.62 8.0 4.97 3.9 4.4 0.0056 0.76 1.68 7.9 4.9 3.3 3.7 0.0027 0.79 1.62 7.0 4.94 2.9 3.7 0.0033 0.80 2.3 7.9 7.2 3.3 3.9 0.0055 0.78 3.2 8.2 9.9 3.5 4.0 0.0055 0.83 4.3 8.9 14.5 3.1 4.1 0.0144 0.83 5.9 9.0 19.7 3.5 4.2 0.0144 0.75 8.7 6.9 26.3 3.1 3.3 0.0176 0.74 11.9 7.6 36 2.8 3.9 0.0295 0.81 14.7 7.7 48.9 2.5 3.6 0.0414 0.82 21.1 7.6 71.27 2.6 3.3 0.11 0.82 28.5 8.2 96.99 3.0 3.7 0.135 0.83 34.9 7.2 119 2.8 3.0 0.219 0.82 41.5 8.2 141 2.8 3.1 0.217 0.84 54.8 7.5 193 2.7 3.2 0.385 0.83 68.9 7.2 239 3.1 3.1 0.427 0.84 82.3 8.0 290 3.2 3.5 0.525 0.85 97.8 7.9 353 3.0 3.3 0.933 0.86 133 6.4 483 2.3 2.8 1.38 0.86 158 7.1 578 2.5 2.9 1.73 0.85 194 7.8 704 2.4 3.1 2.9 0.85 234 7.9 846 2.6 3.2 3.2 0.87 278 7.9 1026 2.7 3.0 3.9 0.87 345 7.3 1282 2.1 2.7 5.9 0.86 435 6.4 1601 2.1 2.9 5.9 0.85 550 7.3 2018 2.4 3.3 6.9 0.86 616 6.3 2273 2.3 2.8 7.2 Weight kg Sound pressure Level LPA dB 30 53 22 54 22 57 33 56 34 55 49 54 49 54 52 59 81 70 81 64 188 61 187 61 235 60 235 62 319 63 398 67 398 66 476 67 665 72 725 72 1000 68 1065 68 1220 68 1610 74 1780 78 1820 78 2140 78 Output kW Motor type Product code 1500 r/min = 4 poles 200 M3BP 315LKB 4 250 M3BP 315LKC 4 3GBP312820-··K 3GBP312830-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1487 1490 400 V 50 Hz 96.0 96.4 96.6 96.9 96.4 96.8 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.86 351 6.8 1284 2.4 3.0 3.9 0.87 432 7.8 1601 2.3 3.0 5.5 Weight kg Sound pressure Level LPA dB 1520 74 1600 74 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 38 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1000 r/min = 6 poles 0.75 M3BP 90LG 6 3GBP093570-··K 1.1 M3BP 100LKG 6 3GBP103870-··K 1.5 M3BP 112MH 6 3GBP113380-··K 2.2 M3BP 132SMC 6 3GBP133230-··K 3 M3BP 132SMD 6 3GBP133240-··K 4 M3BP 132SMG 6 3GBP133270-··K 5.5 M3BP 132SMH 6 3GBP133280-··K 7.5 M3BP 160MLA 6 3GBP163410-··K 11 M3BP 160MLB 6 3GBP163420-··K 15 M3BP 180MLA 6 3GBP183410-··K 18.5 M3BP 200MLA 6 3GBP203410-··K 22 M3BP 200MLB 6 3GBP203420-··K 30 M3BP 225SMA 6 3GBP223210-··K 37 M3BP 250SMA 6 3GBP253210-··K 45 M3BP 280SMB 6 3GBP283220-··K 55 M3BP 280SMC 6 3GBP283230-··K 75 M3BP 315SMC 6 3GBP313230-··K 90 M3BP 315SMD 6 3GBP313240-··K 110 M3BP 315MLB 6 3GBP313420-··K 132 M3BP 315LKA 6 3GBP313810-··K 160 M3BP 355SMB 6 3GBP353220-··K 200 M3BP 355SMC 6 3GBP353230-··K 250 M3BP 355MLB 6 3GBP353420-··K 315 M3BP 355LKA 6 3GBP353810-··K 355 M3BP 355LKB 6 3GBP353820-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 938 81.5 82.8 82.2 969 84.4 84.5 82.8 972 85.8 85.6 83.6 978 87.3 87.5 86.1 977 88.5 88.8 87.5 974 89.4 89.9 89.3 966 89.6 90.4 90.2 980 90.8 91.5 91.0 979 91.2 91.8 91.1 981 92.2 92.5 91.5 990 92.8 93.2 92.6 990 93.3 93.7 93.1 989 94.1 94.7 94.5 991 94.4 94.9 94.7 992 94.7 95.1 94.6 990 95.0 95.4 95.0 994 95.3 95.6 95.2 994 95.5 95.8 95.4 994 95.7 95.9 95.7 993 95.9 96.1 95.9 995 96.1 96.1 95.6 995 96.2 96.4 96.1 995 96.4 96.6 96.5 994 96.5 96.7 96.4 995 96.5 96.6 96.1 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.74 1.8 4.8 7.7 2.4 2.7 0.0072 0.68 2.6 4.1 10.9 1.6 2.2 0.0025 0.64 3.8 4.5 14.7 1.3 2.5 0.0196 0.69 5.1 5.4 21.5 2.0 2.6 0.0416 0.69 6.9 5.9 29 1.4 2.8 0.0416 0.69 9.3 5.6 38.7 2.2 2.8 0.0416 0.73 12.1 5.0 54.1 1.8 2.7 0.0654 0.78 15.2 7.9 73 1.7 3.3 0.114 0.74 23.5 8.5 107 2.2 3.9 0.131 0.77 30.4 5.5 146 1.7 2.7 0.225 0.77 37.3 7.5 178 2.6 3.2 0.448 0.79 43 7.8 212 2.6 3.2 0.531 0.81 56.8 7.9 289 2.8 3.1 0.813 0.83 68 7.7 356 2.7 2.9 1.49 0.85 80.9 6.9 434 2.4 2.6 2.2 0.85 99.4 6.8 506 2.4 2.6 2.85 0.83 138 7.0 721 2.2 2.8 4.9 0.81 170 7.2 864 2.4 2.9 4.9 0.83 202 6.9 1058 2.3 2.7 6.3 0.82 243 6.9 1269 2.4 2.7 7.3 0.82 294 7.0 1536 2.1 2.7 9.7 0.82 367 7.3 1920 2.3 2.8 11.3 0.83 456 7.1 2399 2.3 2.7 13.5 0.83 576 6.9 3026 2.3 2.6 15.5 0.81 668 7.7 3407 2.7 2.9 16.5 Weight kg Sound pressure Level LPA dB 34 44 47 49 53 66 81 57 82 57 82 57 79 57 172 59 198.7 59 234 59 291 63 318 63 392 63 467 63 680 65 725 65 1000 67 1040 67 1200 68 1410 68 1680 73 1820 73 2180 73 2500 76 2600 76 Output kW Motor type Product code 1000 r/min = 6 poles 160 M3BP 315LKC 6 3GBP313830-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 994 96.1 96.3 96.2 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.82 297 7.4 1537 2.7 2.9 9.2 Weight kg Sound pressure Level LPA dB 1600 68 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. ABB Motors and Generators | 9AKK105944 EN 02-2020 39 Technical data, 460 V 60 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3600 r/min = 2 poles 0.75 M3BP 80MD 2 3GBP081340-··K 1.1 M3BP 80MG 2 3GBP081370-··K 1.5 M3BP 90LB 2 3GBP091520-··K 2.2 M3BP 90LC 2 3GBP091530-··K 3 M3BP 100LKA 2 3GBP101810-··K 4 M3BP 112MG 2 3GBP111370-··K 5.5 M3BP 132SMF 2 3GBP131260-··K 7.5 M3BP 132SMG 2 3GBP131270-··K 11 M3BP 160MLA 2 3GBP161410-··K 15 M3BP 160MLB 2 3GBP161420-··K 18.5 M3BP 160MLC 2 3GBP161430-··K 22 M3BP 180MLA 2 3GBP181410-··K 30 M3BP 200MLA 2 3GBP201410-··K 37 M3BP 200MLB 2 3GBP201420-··K 45 M3BP 225SMA 2 3GBP221210-··K 55 M3BP 250SMA 2 3GBP251210-··K 75 M3BP 280SMB 2 3GBP281220-··K 90 M3BP 280SMC 2 3GBP281230-··K 110 M3BP 315SMB 2 3GBP311220-··K 132 M3BP 315SMC 2 3GBP311230-··K 160 M3BP 315MLA 2 3GBP311410-··K 200 1) M3BP 355SMA 2 3GBP351210-··K 250 1) M3BP 355SMB 2 3GBP351220-··K 315 1) M3BP 355SMC 2 3GBP351230-··K 355 1) M3BP 355MLA 2 3GBP351410-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 3502 3500 3522 3517 3512 3500 3519 3524 3549 3554 3555 3560 3562 3564 3570 3569 3579 3582 3598 3586 3585 3586 3585 3582 3586 460 V 60 Hz 77.0 75.2 84.0 83.0 85.5 85.3 86.5 87.1 88.5 88.7 88.5 88.9 89.5 89.4 90.2 90.7 91.0 91.1 91.0 90.4 93.5 93.6 91.7 91.7 92.4 92.0 93.0 92.8 93.6 93.1 93.6 93.1 94.1 93.4 95.3 94.9 95.3 94.9 95.7 95.4 95.4 94.9 96.1 95.8 95.8 95.3 95.8 95.5 95.8 95.3 70.0 80.2 84.0 85.8 87.3 87.9 88.7 90.0 89.9 89.6 92.7 90.4 90.4 91.1 91.5 91.6 91.6 93.7 93.5 94.2 93.6 94.8 94.0 94.3 94.2 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.72 1.56 8.9 2 4.3 5.2 0.0008 0.78 2.0 9.9 3 3.6 5.3 0.001 0.88 2.4 9.6 4 2.5 4.0 0.0027 0.88 3.5 9.9 5.9 3.2 4.2 0.0032 0.89 4.7 9.9 8.1 3.5 4.6 0.0057 0.90 6.2 10.0 10.9 3.6 4.8 0.0104 0.90 8.4 9.1 14.9 2.5 3.9 0.0154 0.90 11.4 9.6 20.3 3.1 4.5 0.0173 0.91 16.6 8.7 29.54 2.7 3.9 0.057 0.89 22.7 8.5 40.27 3.8 4.8 0.063 0.89 27.9 10.5 49.64 3.8 4.7 0.076 0.89 33 9.2 58.96 4.1 4.7 0.11 0.90 44.9 8.7 80.4 2.8 3.4 0.178 0.89 55.8 9.2 99.1 3.1 3.7 0.196 0.89 67.4 7.8 120 2.8 3.7 0.296 0.90 82.7 7.9 147 2.3 3.3 0.426 0.87 115 7.9 200 2.7 3.4 0.9 0.88 133 9.0 240 3.4 3.4 1.15 0.88 165 7.5 293 1.9 2.9 1.4 0.88 197 8.9 351 2.4 3.3 1.7 0.87 242 8.3 426 2.2 3.1 1.7 0.88 295 8.5 533 2.0 3.4 3 0.89 370 8.6 665 1.8 3.7 3 0.89 466 7.8 839 2.2 3.3 3.4 0.88 528 8.1 945 2.2 3.3 3.6 Weight kg Sound pressure Level LPA dB 18 61 19 60 31 65 35 65 50 65 56 71 77 74 77 73 141 75 170 74 183 75 234 77 289 76 314 76 409 79 452 81 665 74 725 80 940 80 1025 80 1190 81 1600 86 1680 86 1750 86 2000 88 Output kW Motor type Product code 3600 r/min = 2 poles 200 M3BP 315MLB 2 250 M3BP 315LKB 2 3GBP311420-··K 3GBP311820-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 3585 3583 460 V 60 Hz 95.8 95.6 96.1 96.1 94.6 95.8 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.88 298 8.7 533 2.6 3.4 2.1 0.91 359 9.0 666 2.6 3.0 2.9 Weight kg Sound pressure Level LPA dB 1220 84 1540 80 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 40 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 460 V 60 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1800 r/min = 4 poles 0.55 M3BP 80MLD 4 3GBP082440-··K 0.75 M3BP 90L 4 3GBP092500-··K 1.1 M3BP 90LC 4 3GBP092530-··K 1.5 M3BP 90LD 4 3GBP092540-··K 2.2 M3BP 100LKA 4 3GBP102810-··K 3 M3BP 100LKB 4 3GBP102820-··K 4 M3BP 112MG 4 3GBP112370-··K 5.5 M3BP 132SMF 4 3GBP132260-··K 7.5 M3BP 132SMG 4 3GBP132270-··K 11 M3BP 160MLA 4 3GBP162410-··K 15 M3BP 160MLB 4 3GBP162420-··K 18.5 M3BP 180MLA 4 3GBP182410-··K 22 M3BP 180MLB 4 3GBP182420-··K 30 M3BP 200MLA 4 3GBP202410-··K 37 M3BP 225SMA 4 3GBP222210-··K 45 M3BP 225SMB 4 3GBP222220-··K 55 M3BP 250SMA 4 3GBP252210-··K 75 M3BP 280SMB 4 3GBP282220-··K 90 M3BP 280SMC 4 3GBP282230-··K 110 M3BP 315SMC 4 3GBP312230-··K 132 M3BP 315SMD 4 3GBP312240-··K 160 M3BP 315MLB 4 3GBP312420-··K 200 M3BP 355SMA 4 3GBP352210-··K 250 M3BP 355SMB 4 3GBP352220-··K 315 M3BP 355SMC 4 3GBP352230-··K 355 M3BP 355MLA 4 3GBP352410-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1747 1754 1749 1748 1760 1759 1760 1767 1766 1780 1780 1783 1783 1785 1783 1784 1787 1785 1786 1792 1791 1791 1792 1792 1793 1791 460 V 60 Hz 83.9 84 85.4 84.3 86.5 85.4 86.5 85.1 89.5 89.2 89.5 89.3 89.8 89.7 91.7 91.1 91.7 91.6 92.4 92.2 93.0 92.7 93.6 93.7 93.8 94.2 94.1 94.1 94.5 94.7 95.0 94.9 95.7 95.8 95.4 95.2 95.4 95.2 96.1 96.0 96.4 96.3 96.4 96.4 96.4 96.2 96.2 95.9 96.2 96.0 96.2 96.0 82.1 81.0 82.5 82.0 87.4 87.4 88.3 89.6 90.8 90.9 91.4 93.1 93.7 93.1 94.1 95.0 95.2 94.1 94.2 95.3 95.6 95.9 95.4 95.0 95.1 95.2 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.79 1.03 7.6 3 3.1 4 0.0028 0.76 1.45 9.3 4.1 4.2 5.2 0.0056 0.77 2.0 8.4 6 3.7 4.6 0.0055 0.75 2.9 9.5 8.1 4.0 5.0 0.0055 0.81 3.8 10.2 11.9 3.3 4.7 0.0144 0.81 5.2 10.4 16.3 3.8 4.9 0.0144 0.74 7.6 8.8 21.7 3.8 4.4 0.0176 0.73 10.4 8.7 29.81 3.0 4.5 0.0295 0.79 13 8.7 40.5 2.6 3.9 0.0414 0.80 18.9 8.7 59.14 3.4 3.7 0.11 0.82 24.7 9.5 80.47 3.3 4.1 0.135 0.82 30.3 8.4 99.04 3.1 3.5 0.219 0.82 35.8 9.3 117 3.0 3.4 0.217 0.84 47.7 8.2 161 2.8 3.9 0.385 0.83 59.3 8.8 198 3.6 3.5 0.427 0.83 71.8 8.8 241 2.9 4.7 0.525 0.84 85.8 9.1 293 3.3 3.7 0.933 0.84 117 7.4 401 2.5 3.1 1.38 0.85 139 8.2 481 2.7 3.2 1.73 0.84 172 8.8 586 2.6 3.4 2.9 0.84 206 9.0 704 2.8 3.6 3.2 0.86 241 9.0 853 2.9 3.3 3.9 0.87 301 8.3 1065 2.2 3.0 5.9 0.85 380 7.3 1333 2.2 3.2 5.9 0.86 478 7.6 1679 2.5 3.5 6.9 0.86 541 7.2 1893 2.4 3.1 7.2 Weight kg Sound pressure Level LPA dB 20 48 30 56 33 56 34 58 49 57 49 57 52 62 81 73 81 69 188 68 187 67 235 68 235 66 319 69 398 65 398 72 476 71 665 75 725 75 1000 71 1065 71 1220 71 1610 77 1780 81 1820 81 2140 81 Output kW Motor type Product code 1800 r/min = 4 poles 200 M3BP 315LKB 4 250 M3BP 315LKC 4 250 M3BP 315LKC 4 3GBP312820-··K 3GBP312830-··K 3GBP312830-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1788 1791 1791 460 V 60 Hz 96.2 96.2 96.7 96.7 97.0 97.0 95.6 96.4 96.7 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.86 305 7.8 1068 2.6 3.3 3.9 0.86 376 8.9 1332 2.5 3.3 5.5 0.86 376 8.9 1332 2.5 3.3 5.5 Weight kg Sound pressure Level LPA dB 1520 77 1600 77 1600 77 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. ABB Motors and Generators | 9AKK105944 EN 02-2020 41 Technical data, 460 V 60 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1200 r/min = 6 poles 0.75 M3BP 90LG 6 3GBP093570-··K 1.1 M3BP 100LKG 6 3GBP103870-··K 1.5 M3BP 112MH 6 3GBP113380-··K 2.2 M3BP 132SMC 6 3GBP133230-··K 3 M3BP 132SMD 6 3GBP133240-··K 4 M3BP 132SMG 6 3GBP133270-··K 5.5 M3BP 132SMH 6 3GBP133280-··K 7.5 M3BP 160MLA 6 3GBP163410-··K 11 M3BP 160MLB 6 3GBP163420-··K 15 M3BP 180MLA 6 3GBP183410-··K 18.5 M3BP 200MLA 6 3GBP203410-··K 22 M3BP 200MLB 6 3GBP203420-··K 30 M3BP 225SMA 6 3GBP223210-··K 37 M3BP 250SMA 6 3GBP253210-··K 45 M3BP 280SMB 6 3GBP283220-··K 55 M3BP 280SMC 6 3GBP283230-··K 75 M3BP 315SMC 6 3GBP313230-··K 90 M3BP 315SMD 6 3GBP313240-··K 110 M3BP 315MLB 6 3GBP313420-··K 132 M3BP 315LKA 6 3GBP313810-··K 160 M3BP 355SMB 6 3GBP353220-··K 200 M3BP 355SMC 6 3GBP353230-··K 250 M3BP 355MLB 6 3GBP353420-··K 315 M3BP 355LKA 6 3GBP353810-··K 355 M3BP 355LKB 6 3GBP353820-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1146 1171 1174 1180 1179 1177 1169 1182 1183 1183 1191 1191 1191 1192 1193 1190 1195 1195 1194 1194 1195 1196 1195 1195 1195 460 V 60 Hz 83.4 83.4 88.0 88.0 89.4 89.0 90.1 89.6 90.1 89.7 90.1 90.0 91.0 91.2 91.4 91.5 91.7 91.8 92.3 92.0 93.3 93.2 93.8 93.8 94.2 94.3 94.5 94.7 95.3 95.2 95.3 95.3 96.3 96.1 95.7 95.6 96.1 96.0 96.1 96.0 96.1 96.0 96.1 95.7 96.4 96.4 96.4 96.4 96.4 96.1 81.2 86.4 87.1 87.6 87.9 88.6 90.3 90.3 90.5 90.5 92.1 92.8 93.6 94.1 94.3 94.5 95.4 94.9 95.4 95.5 95.3 95.0 95.8 95.8 95.3 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.72 1.6 5.5 6.3 2.6 3.2 0.0072 0.66 2.3 4.6 9 1.3 2.7 0.0025 0.62 3.4 7.5 12.2 3.0 5.2 0.0196 0.68 4.5 6.5 17.8 2.1 3.3 0.0416 0.68 6.1 6.5 24 1.4 3.1 0.0416 0.68 8.1 6.3 32 2.3 3.2 0.0416 0.72 10.6 5.7 44.7 2.0 3.1 0.0654 0.76 13.5 8.6 60.5 1.8 3.7 0.114 0.73 20.6 9.4 88.7 2.3 4.4 0.131 0.75 27.1 6.0 121 1.8 3.1 0.225 0.77 32.3 8.6 148 2.9 3.6 0.448 0.78 37.7 8.8 176 2.9 3.6 0.531 0.80 49.9 8.9 240 3.2 3.5 0.813 0.82 59.9 8.6 296 3.0 3.2 1.49 0.85 70.6 7.9 361 2.6 2.9 2.2 0.85 86.2 7.8 420 2.6 2.9 2.85 0.82 121 7.9 600 2.5 3.1 4.9 0.80 149 8.2 719 2.7 3.2 4.9 0.81 177 7.9 880 2.6 3.0 6.3 0.81 215 7.9 1055 2.7 3.0 7.3 0.81 260 7.9 1278 2.3 3.0 9.7 0.82 320 8.3 1598 2.5 3.1 11.3 0.82 401 9.2 1997 2.3 3.0 13.5 0.83 500 7.9 2516 2.6 2.9 15.5 0.80 584 8.8 2835 3.0 3.2 16.5 Weight kg Sound pressure Level LPA dB 34 47 47 52 53 69 81 60 82 60 82 60 79 60 172 63 198.7 63 234 63 291 67 318 67 392 67 467 67 680 68 725 68 1000 70 1040 70 1200 71 1410 71 1680 76 1820 76 2180 76 2500 79 2600 79 Output kW Motor type Product code 1200 r/min = 6 poles 160 M3BP 315LKC 6 3GBP313830-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 460 V 60 Hz 1195 96.1 96.0 95.3 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.81 259 8.4 1279 3.0 3.2 9.2 Weight kg Sound pressure Level LPA dB 1600 71 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 42 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3000 r/min = 2 poles 0.55 M3BP 71ME 2 3GBP071350-··L 0.75 M3BP 80MC 2 3GBP081330-··L 1.1 M3BP 80ME 2 3GBP081350-··L 1.5 M3BP 90SLA 2 3GBP091010-··L 2.2 M3BP 90LA 2 3GBP091510-··L 3 M3BP 100MLA 2 3GBP101410-··L 4 M3BP 112ME 2 3GBP111350-··L 5.5 M3BP 132SMC 2 3GBP131230-··L 7.5 M3BP 132SME 2 3GBP131250-··L 11 M3BP 160MLA 2 3GBP161410-··L 15 M3BP 160MLB 2 3GBP161420-··L 18.5 M3BP 160MLC 2 3GBP161430-··L 22 M3BP 180MLA 2 3GBP181410-··L 30 M3BP 200MLA 2 3GBP201410-··L 37 M3BP 200MLB 2 3GBP201420-··L 45 M3BP 225SMA 2 3GBP221210-··L 55 M3BP 250SMA 2 3GBP251210-··L 75 M3BP 280SMB 2 3GBP281220-··L 90 M3BP 280SMC 2 3GBP281230-··L 110 M3BP 315SMB 2 3GBP311220-··L 132 M3BP 315SMC 2 3GBP311230-··L 160 M3BP 315SMD 2 3GBP311240-··L 200 M3BP 315MLA 2 3GBP311410-··L 250 1) M3BP 355SMA 2 3GBP351210-··L 315 1) M3BP 355SMB 2 3GBP351220-··L 355 1) M3BP 355SMC 2 3GBP351230-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 2755 2894 2883 2906 2900 2896 2888 2901 2909 2943 2947 2949 2943 2956 2959 2968 2968 2977 2976 2982 2982 2983 2983 2985 2980 2984 400 V 50 Hz 77.8 79.3 80.7 80.4 82.7 82.4 84.2 84.7 85.9 87.5 87.1 88.2 88.1 89.4 89.2 89.9 90.1 91.2 91.2 91.9 91.9 92.2 92.4 92.9 93.0 93.7 93.3 93.7 93.7 93.9 94.0 94.0 94.3 93.7 94.7 94.2 95.0 95.1 95.2 94.9 95.4 95.1 95.6 95.6 95.8 95.8 95.8 95.6 95.8 95.7 95.8 95.8 78.4 77.2 80.6 84.6 87.6 88.0 89.6 90.1 91.4 91.6 91.8 92.6 93.6 93.0 93.2 93.1 93.6 92.8 94.3 93.9 94.0 94.9 95.3 94.6 95.0 95.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.83 1.25 6.8 1.9 2.8 3.1 0.00045 0.74 1.7 7.9 2.4 3.7 4.2 0.0008 0.81 2.3 7.9 3.6 3.7 4.2 0.001 0.89 2.8 7.9 4.9 2.3 3.3 0.0027 0.89 4.0 8.3 7.2 2.9 3.5 0.0032 0.90 5.4 8.4 9.8 3.2 3.9 0.0057 0.91 7.1 8.4 13.2 3.2 4.0 0.0104 0.91 9.7 7.9 18.1 2.3 3.4 0.0154 0.90 13.1 8.3 24.6 3.0 3.9 0.0173 0.91 19.1 7.2 35.57 2.6 3.6 0.057 0.88 26.5 8.2 48.49 3.2 4.2 0.063 0.90 32 9.0 59.81 3.3 3.9 0.076 0.93 36.8 6.7 70.98 2.0 2.9 0.11 0.90 51.6 7.7 96.9 2.7 3.1 0.178 0.90 63.5 8.2 119 3.0 3.3 0.196 0.87 79.6 7.2 145 2.5 3.1 0.296 0.89 94.8 6.8 177 2.4 3.0 0.426 0.88 131 7.6 240 2.1 3.0 0.8 0.89 154 7.4 288 2.1 2.9 0.9 0.87 192 7.0 352 1.8 2.7 1.3 0.88 227 7.4 422 2.2 3.0 1.4 0.87 275 7.4 512 2.2 2.8 1.7 0.88 342 7.7 640 2.5 3.1 2.1 0.89 423 7.7 800 2.1 3.3 3 0.89 529 7.0 1009 2.1 3.0 3.4 0.88 605 7.2 1136 2.2 3.0 3.6 Weight kg Sound pressure Level LPA dB 11 56 17 57 18 56 27 60 30 60 42 62 56 68 69 68 75 70 144 69 152 69 164 73 205 73 263 72 289 72 335 76 400 76 665 77 690 77 910 78 965 78 1025 78 1190 81 1600 83 1680 83 1750 83 Output kW Motor type Product code 3000 r/min = 2 poles 22 M3BP 160MLD 2 3GBP161440-··L 30 M3BP 180MLB 2 3GBP181420-··L 37 M3BP 180MLC 2 3GBP181430-··L 45 M3BP 200MLC 2 3GBP201430-··L 55 M3BP 225SMB 2 3GBP221220-··L 75 2) M3BP 225SMC 2 3GBP221230-··L 75 M3BP 250SMB 2 3GBP251220-··L 90 2) M3BP 250SMC 2 3GBP251230-··L 110 M3BP 280SMD 2 3GBP281240-··L 250 M3BP 315LKB 2 3GBP311820-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 2944 2957 2952 2955 2966 2966 2971 2968 2977 2983 400 V 50 Hz 92.7 93.5 93.3 94.0 93.7 94.5 94.0 94.5 94.3 94.6 94.7 94.8 94.7 95.1 95.0 95.4 95.2 95.2 95.8 96.0 93.5 93.9 94.5 94.4 94.1 94.1 94.8 95.0 94.4 95.5 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.90 38 8.4 71.36 3.2 3.7 0.071 0.88 52.7 8.7 96.88 3.0 3.8 0.104 0.88 64.7 8.7 120 3.1 3.7 0.115 0.89 77.6 8.0 145 2.9 3.3 0.214 0.88 95.6 7.4 177 2.9 2.9 0.274 0.88 129 8.1 241 3.3 3.0 0.329 0.90 127 7.9 241 2.8 3.3 0.644 0.90 151 8.4 290 2.7 3.4 0.644 0.88 190 7.5 353 2.4 3.1 1.15 0.90 419 7.7 800 2.5 3.3 2.9 Weight kg Sound pressure Level LPA dB 174 74 215 74 229 74 305 77 355 79 408 79 479 81 495 81 725 75 1540 81 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2 ABB Motors and Generators | 9AKK105944 EN 02-2020 43 Technical data, 400 V 50 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1500 r/min = 4 poles 0.25 M3BP 71MD 4 3GBP072340-··L 0.37 M3BP 71MLE 4 3GBP072450-··L 0.55 M3BP 80MLC 4 3GBP082430-··L 0.75 M3BP 80MLE 4 3GBP082450-··L 1.1 M3BP 90LA 4 3GBP092510-··L 1.5 M3BP 90LB 4 3GBP092520-··L 2.2 M3BP 100LA 4 3GBP102510-··L 3 M3BP 100MLB 4 3GBP102420-··L 4 M3BP 112ME 4 3GBP112350-··L 5.5 M3BP 132SMB 4 3GBP132220-··L 7.5 M3BP 132SME 4 3GBP132250-··L 11 M3BP 160MLA 4 3GBP162410-··L 15 M3BP 160MLB 4 3GBP162420-··L 18.5 M3BP 180MLA 4 3GBP182410-··L 22 M3BP 180MLB 4 3GBP182420-··L 30 M3BP 200MLA 4 3GBP202410-··L 37 M3BP 225SMA 4 3GBP222210-··L 45 M3BP 225SMB 4 3GBP222220-··L 55 M3BP 250SMA 4 3GBP252210-··L 75 M3BP 280SMB 4 3GBP282220-··L 90 M3BP 280SMC 4 3GBP282230-··L 110 M3BP 315SMB 4 3GBP312220-··L 132 M3BP 315SMC 4 3GBP312230-··L 160 M3BP 315SMD 4 3GBP312240-··L 200 M3BP 315MLB 4 3GBP312420-··L 315 M3BP 355SMB 4 3GBP352220-··L 355 M3BP 355SMC 4 3GBP352230-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1416 1432 1444 1448 1437 1445 1455 1445 1451 1460 1462 1477 1477 1481 1481 1483 1482 1482 1482 1485 1485 1489 1488 1488 1487 1491 1490 400 V 50 Hz 73.5 75.1 77.3 77.4 80.8 81.6 82.5 82.5 84.1 83.7 85.3 85.0 86.7 86.6 87.7 88.2 88.6 89.4 89.6 90.1 90.4 91.0 91.4 91.8 92.1 92.3 92.6 93.2 93.0 93.5 93.6 93.9 93.9 94.1 94.2 94.4 94.6 94.7 95.0 95.2 95.2 95.5 95.4 95.5 95.6 95.9 95.8 96.0 96.0 96.4 96.0 96.1 96.0 96.2 73.8 74.5 80.1 80.1 81.2 82.7 84.6 87.6 89.0 89.6 90.3 91.1 91.6 92.9 93.3 93.4 93.8 94.0 94.1 94.8 95.2 95.0 95.5 95.8 96.4 95.7 95.8 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.80 0.6 4.8 1.68 2.0 2.6 0.0009 0.76 0.9 5.8 2.46 2.7 3.3 0.00122 0.80 1.2 6.7 4 3.0 3.5 0.0028 0.78 1.7 7.4 4.9 3.5 4.0 0.0033 0.78 2.46 8.0 7.32 3.3 3.8 0.007 0.75 3.34 7.6 9.95 3.4 4.1 0.007 0.80 4.6 7.9 14.4 3.2 4.0 0.011 0.83 5.9 7.7 19.8 2.8 3.5 0.014 0.77 8.6 7.6 26.3 3.1 4.1 0.018 0.82 11 6.6 35.9 2.2 3.3 0.031 0.79 15.6 6.7 48.9 2.5 3.4 0.037 0.82 21.1 7.6 71.27 2.6 3.3 0.11 0.82 28.5 8.2 96.99 3.0 3.7 0.135 0.83 34.9 7.2 119 2.8 3.0 0.219 0.82 41.4 8.3 142 3.0 3.2 0.243 0.84 54.8 7.5 193 2.7 3.2 0.385 0.83 68.9 7.2 239 3.1 3.1 0.427 0.84 82.3 8.0 290 3.2 3.5 0.525 0.84 100 7.1 354 2.9 3.4 0.694 0.86 133 6.4 483 2.3 2.8 1.38 0.86 158 7.1 578 2.5 2.9 1.73 0.84 198 7.0 705 2.1 3.0 2.43 0.86 231 6.7 847 2.2 2.9 2.9 0.85 282 6.9 1026 2.2 3.0 3.2 0.86 351 6.8 1284 2.4 3.0 3.9 0.85 550 7.3 2018 2.4 3.3 6.9 0.86 616 6.3 2273 2.3 2.8 7.2 Weight kg Sound pressure Level LPA dB 11 45 15 45 20 45 22 50 28 50 32 50 38 54 42 63 52 64 68 66 78 63 160 61 179 61 215 60 229 60 292 63 322 67 357 66 406 68 645 75 700 75 930 71 1000 71 1065 71 1220 74 1780 78 1820 78 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2 44 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1500 r/min = 4 poles 18.5 M3BP 160MLC 4 3GBP162430-··L 30 M3BP 180MLC 4 3GBP182430-··L 37 M3BP 200MLB 4 3GBP202420-··L 55 M3BP 225SMC 4 3GBP222230-··L 75 M3BP 250SMB 4 3GBP252220-··L 110 M3BP 280SMD 4 3GBP282240-··L 132 M3BP 280MLA 4 3GBP282410-··L 160 M3BP 280MLB 4 3GBP282420-··L 280 M3BP 315LKB 4 3GBP312820-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1473 1476 1480 1478 1482 1486 1483 1484 1488 400 V 50 Hz 92.6 93.3 93.6 94.1 93.9 94.8 94.6 94.9 95.0 95.4 95.4 95.7 95.6 95.9 95.8 96.0 96.0 96.2 93.1 94.1 94.8 94.8 95.0 95.3 95.7 95.8 96.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.82 35.1 8.3 120 3.1 3.5 0.124 0.82 56.5 7.4 195 2.5 3.2 0.191 0.82 69.3 7.5 239 2.8 2.9 0.362 0.84 99.9 7.7 355 3.3 3.3 0.536 0.84 135 7.9 483 3.3 3.5 0.941 0.85 196 7.3 707 2.7 3.0 1.95 0.86 232 7.0 849 2.7 2.8 2.3 0.86 280 7.4 1029 2.9 2.9 2.5 0.86 490 7.8 1797 2.7 3.1 5 Weight kg Sound pressure Level LPA dB 180 67 235 62 305 68 391 71 464 73 750 76 840 75 890 75 1520 78 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2 ABB Motors and Generators | 9AKK105944 EN 02-2020 45 Technical data, 400 V 50 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1000 r/min = 6 poles 0.25 M3BP 80MB 6 3GBP083320-··L 0.75 M3BP 90SLD 6 3GBP093040-··L 1.1 M3BP 90LF 6 3GBP093560-··L 1.5 M3BP 100MLB 6 3GBP103420-··L 2.2 M3BP 112MJ 6 3GBP113390-··L 3 M3BP 132SMB 6 3GBP133220-··L 4 M3BP 132SMF 6 3GBP133260-··L 5.5 M3BP 132SMJ 6 3GBP133290-··L 7.5 M3BP 160MLA 6 3GBP163410-··L 11 M3BP 160MLB 6 3GBP163420-··L 15 M3BP 180MLA 6 3GBP183410-··L 18.5 M3BP 200MLA 6 3GBP203410-··L 22 M3BP 200MLB 6 3GBP203420-··L 30 M3BP 225SMA 6 3GBP223210-··L 37 M3BP 250SMA 6 3GBP253210-··L 45 M3BP 280SMB 6 3GBP283220-··L 55 M3BP 280SMC 6 3GBP283230-··L 75 M3BP 315SMB 6 3GBP313220-··L 90 M3BP 315SMC 6 3GBP313230-··L 110 M3BP 315SMD 6 3GBP313240-··L 132 M3BP 315MLB 6 3GBP313420-··L 160 M3BP 355SMA 6 3GBP353210-··L 200 M3BP 355SMB 6 3GBP353220-··L 250 M3BP 355SMC 6 3GBP353230-··L 315 M3BP 355MLB 6 3GBP353420-··L 355 M3BP 355LKA 6 3GBP353810-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 942 68.6 67.0 61.7 940 78.9 80.3 79.2 944 81.0 81.7 80.1 960 82.5 82.5 80.1 962 84.3 85.5 84.7 973 85.6 85.1 82.9 971 86.8 86.5 84.7 966 88.0 89.1 88.9 975 89.1 90.0 90.0 975 90.3 91.2 91.1 979 91.2 91.9 91.6 989 91.7 91.9 91.3 989 92.2 92.4 91.5 988 92.9 93.0 92.2 990 93.3 93.7 93.5 991 93.7 94.0 93.5 992 94.1 94.3 93.8 994 94.6 94.9 94.6 994 94.9 95.1 94.7 994 95.1 95.3 95.0 995 95.4 95.5 95.1 993 95.6 95.8 95.6 993 95.8 96.2 96.1 993 95.8 96.1 95.8 993 95.8 96.1 96.0 993 95.8 96.0 95.9 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.61 0.82 4.8 2.5 2.7 2.9 0.0019 0.75 1.8 4.4 7.57 2.1 2.8 0.0056 0.75 2.62 4.7 11.1 2.1 2.8 0.0068 0.68 3.8 5.4 14.9 2.7 3.4 0.012 0.68 5.3 5.9 21.8 2.3 3.3 0.0196 0.62 8.0 6.6 29.2 2.7 3.8 0.0355 0.62 10.7 6.6 39 2.7 3.8 0.0416 0.73 12.3 4.2 54 1.7 2.7 0.0408 0.77 15.7 5.7 73.24 1.4 3.0 0.089 0.78 22.5 6.4 108 1.6 3.1 0.138 0.79 30.1 5.2 147 1.5 2.7 0.212 0.82 35.2 6.5 179 2.2 3.2 0.496 0.81 42.4 7.3 212 2.6 3.5 0.585 0.77 60.4 7.7 291 2.9 3.6 0.724 0.80 71.1 6.5 357 2.4 3.1 1.3 0.84 82 7.4 433 2.7 3.0 1.87 0.86 99 7.5 528 2.8 3.0 2.57 0.84 136 6.8 720 1.8 2.6 4.1 0.84 164 7.2 864 2.0 3.0 4.6 0.83 200 7.3 1056 2.2 3.1 4.9 0.82 242 7.3 1266 2.3 3.2 6.3 0.82 292 6.7 1538 2.5 2.6 7.9 0.82 365 6.7 1923 2.6 2.5 9.7 0.81 465 7.7 2404 3.0 3.1 11.3 0.83 571 6.8 3029 2.6 3.2 13.5 0.81 653 7.5 3413 2.9 3.2 15.5 Weight kg Sound pressure Level LPA dB 14 47 29 53 33 44 41 49 53 66 75 57 82 57 81 57 146 59 180 64 212 63 272 59 297 59 349 63 431 58 645 72 725 71 930 75 1000 76 1040 75 1200 72 1520 75 1680 75 1820 75 2180 76 2500 76 Output kW Motor type Product code 1000 r/min = 6 poles 18.5 M3BP 180MLB 6 3GBP183420-··L 37 M3BP 225SMB 6 3GBP223220-··L 45 M3BP 250SMB 6 3GBP253220-··L 55 M3BP 250SMC 6 3GBP253230-··L 75 M3BP 280SMD 6 3GBP283240-··L 160 M3BP 315LKA 6 3GBP313810-··L 180 M3BP 315LKB 6 3GBP313820-··L 200 M3BP 315LKC 6 3GBP313830-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 980 91.7 92.5 92.0 985 93.3 93.7 93.4 991 93.7 94.1 93.6 989 94.1 94.7 94.5 991 94.6 94.9 94.5 994 95.6 95.8 95.4 994 95.8 95.9 95.4 993 95.8 96.1 95.8 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.75 38.8 6.4 180 2.1 3.1 0.22 0.80 71.5 7.0 359 2.7 3.0 0.813 0.81 85.5 7.6 434 2.9 3.3 1.5 0.80 105 7.1 531 3.0 3.1 1.49 0.85 135 7.6 723 2.8 3.0 3.0 0.81 298 7.5 1535 2.2 3.1 7.3 0.82 331 7.6 1729 2.3 3.1 8.3 0.82 367 7.0 1923 2.2 2.8 9.2 Weight kg Sound pressure Level LPA dB 219 65 382 68 465 68 466 68 740 73 1410 76 1520 76 1600 76 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2 46 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 460 V 60 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3600 r/min = 2 poles 0.55 M3BP 71ME 2 3GBP071350-··L 0.75 M3BP 80MC 2 3GBP081330-··L 1.1 M3BP 80ME 2 3GBP081350-··L 1.5 M3BP 90SLA 2 3GBP091010-··L 2.2 M3BP 90LA 2 3GBP091510-··L 3 M3BP 100MLA 2 3GBP101410-··L 4 M3BP 112ME 2 3GBP111350-··L 5.5 M3BP 132SMC 2 3GBP131230-··L 7.5 M3BP 132SME 2 3GBP131250-··L 11 M3BP 160MLA 2 3GBP161410-··L 15 M3BP 160MLB 2 3GBP161420-··L 18.5 M3BP 160MLC 2 3GBP161430-··L 22 M3BP 180MLA 2 3GBP181410-··L 30 M3BP 200MLA 2 3GBP201410-··L 37 M3BP 200MLB 2 3GBP201420-··L 45 M3BP 225SMA 2 3GBP221210-··L 55 M3BP 250SMA 2 3GBP251210-··L 75 3) M3BP 280SMB 2 3GBP281220-··L 90 3) M3BP 280SMC 2 3GBP281230-··L 110 M3BP 315SMB 2 3GBP311220-··L 132 3) M3BP 315SMC 2 3GBP311230-··L 160 M3BP 315SMD 2 3GBP311240-··L 200 M3BP 315MLA 2 3GBP311410-··L 250 1) M3BP 355SMA 2 3GBP351210-··L 315 1) M3BP 355SMB 2 3GBP351220-··L 355 1) M3BP 355SMC 2 3GBP351230-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 3386 3502 3500 3522 3517 3512 3500 3519 3524 3549 3554 3555 3560 3562 3564 3570 3569 3579 3578 3584 3584 3585 3585 3586 3583 3585 460 V 60 Hz 76.8 76.7 77.0 75.2 84.0 83.0 85.5 85.3 86.5 87.1 88.5 88.7 88.5 88.9 89.5 89.4 90.2 90.7 91.0 91.1 91.0 90.3 91.7 91.8 91.7 91.7 92.3 92.0 92.9 92.7 93.6 93.2 93.6 93.1 93.0 92.4 93.7 93.2 95.0 94.3 94.1 93.5 95.4 94.9 95.8 95.6 95.8 95.2 95.8 95.4 95.8 95.4 74.0 70.0 80.2 84.0 85.8 87.3 87.9 88.7 90.0 89.9 89.5 90.7 90.3 90.4 91.0 91.5 91.7 90.5 91.7 92.7 91.7 93.6 94.6 93.5 94.2 94.2 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.81 1.1 8.4 1.55 3.3 3.9 0.00045 0.72 1.56 8.9 2 4.3 5.2 0.0008 0.78 2 9.9 3 4.4 5.3 0.001 0.88 2.4 9.6 4 2.5 4.0 0.0027 0.88 3.5 9.9 5.9 3.2 4.2 0.0032 0.89 4.7 9.9 8.1 3.5 4.6 0.0057 0.90 6.2 10.0 10.9 3.6 4.8 0.0104 0.90 8.4 9.1 14.9 2.5 3.9 0.0154 0.90 11.4 9.6 20.3 3.1 4.5 0.0173 0.91 16.6 8.7 29.5 2.7 3.9 0.057 0.89 22.7 8.5 40.3 3.8 4.8 0.063 0.89 27.9 10.5 49.6 3.8 4.7 0.076 0.89 33 9.2 59.0 4.1 4.7 0.11 0.90 44.9 8.7 80.4 2.8 3.4 0.178 0.89 55.8 9.2 99.1 3.1 3.7 0.196 0.89 67.4 7.8 120 2.7 3.7 0.296 0.90 82.7 7.9 147 2.3 3.3 0.426 0.87 116 8.5 199 2.1 3.3 0.8 0.89 135 8.3 239 2.2 3.2 0.9 0.87 168 7.8 293 1.8 3.0 1.3 0.88 200 8.3 351 2.2 3.3 1.4 0.87 242 8.3 426 2.2 3.1 1.7 0.88 298 8.7 533 2.6 3.4 2.1 0.89 373 8.6 666 2.1 3.7 3 0.89 465 7.9 840 2.2 3.3 3.4 0.88 527 8.1 946 2.2 3.3 3.6 Weight kg Sound pressure Level LPA dB 11 59 17 61 18 60 27 65 30 65 42 65 56 71 69 74 75 73 144 75 152 74 164 75 205 77 263 76 289 76 335 79 400 81 665 77 690 82 910 81 965 83 1025 81 1190 84 1600 86 1680 86 1750 86 Output kW Motor type Product code 3600 r/min = 2 poles 22 M3BP 160MLD 2 3GBP161440-··L 30 M3BP 180MLB 2 3GBP181420-··L 37 M3BP 180MLC 2 3GBP181430-··L 45 M3BP 200MLC 2 3GBP201430-··L 55 M3BP 225SMB 2 3GBP221220-··L 75 M3BP 225SMC 2 3GBP221230-··L 75 M3BP 250SMB 2 3GBP251220-··L 90 M3BP 250SMC 2 3GBP251230-··L 110 M3BP 280SMD 2 3GBP281240-··L 250 M3BP 315LKB 2 3GBP311820-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 3552 3563 3560 3562 3571 3571 3575 3573 3580 3585 460 V 60 Hz 91.7 92.0 93.3 93.5 93.0 93.3 93.6 94.0 93.6 93.5 94.1 94.0 94.1 94.1 95.0 95.0 95.0 94.7 95.8 95.6 91.2 92.9 92.7 93.4 92.3 93.0 93.1 94.0 93.4 94.7 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.90 32.9 9.7 59.2 3.5 4.2 0.071 0.88 45.7 10.0 80.4 3.3 4.3 0.104 0.88 56.1 10.0 99.3 3.4 4.2 0.115 0.89 67.2 9.1 121 3.1 3.7 0.214 0.89 82.1 8.5 147 3.0 3.2 0.274 0.89 111 9.3 201 3.4 3.4 0.329 0.90 110 9.0 200 3.0 3.6 0.644 0.90 132 9.5 241 2.8 3.7 0.644 0.88 166 8.5 293 2.5 3.4 1.15 0.90 364 8.8 666 2.6 3.7 2.9 Weight kg Sound pressure Level LPA dB 174 78 215 78 229 78 305 81 355 83 408 83 479 85 495 85 725 78 1540 84 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2 ABB Motors and Generators | 9AKK105944 EN 02-2020 47 Technical data, 460 V 60 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1800 r/min = 4 poles 0.25 M3BP 71MD 4 3GBP072340-··L 0.37 M3BP 71MLE 4 3GBP072450-··L 0.55 M3BP 80MLC 4 3GBP082430-··L 0.75 M3BP 80MLE 4 3GBP082450-··L 1.1 4) M3BP 90LA 4 3GBP092510-··L 1.5 4) M3BP 90LB 4 3GBP092520-··L 2.2 3) M3BP 100LA 4 3GBP102510-··L 3 4) M3BP 100MLB 4 3GBP102420-··L 4 M3BP 112ME 4 3GBP112350-··L 5.5 4) M3BP 132SMB 4 3GBP132220-··L 7.5 4) M3BP 132SME 4 3GBP132250-··L 11 M3BP 160MLA 4 3GBP162410-··L 15 M3BP 160MLB 4 3GBP162420-··L 18.5 M3BP 180MLA 4 3GBP182410-··L 22 M3BP 180MLB 4 3GBP182420-··L 30 M3BP 200MLA 4 3GBP202410-··L 37 M3BP 225SMA 4 3GBP222210-··L 45 M3BP 225SMB 4 3GBP222220-··L 55 M3BP 250SMA 4 3GBP252210-··L 75 4) M3BP 280SMB 4 3GBP282220-··L 90 M3BP 280SMC 4 3GBP282230-··L 110 M3BP 315SMB 4 3GBP312220-··L 132 4) M3BP 315SMC 4 3GBP312230-··L 160 4) M3BP 315SMD 4 3GBP312240-··L 200 M3BP 315MLB 4 3GBP312420-··L 315 M3BP 355SMB 4 3GBP352220-··L 355 M3BP 355SMC 4 3GBP352230-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1727 1740 1749 1753 1743 1751 1760 1748 1755 1763 1765 1777 1780 1783 1784 1785 1783 1784 1785 1785 1786 1791 1790 1790 1788 1792 1791 460 V 60 Hz 73.4 73.4 78.2 77.5 81.1 80.7 83.5 82.9 84.7 83.7 86.4 85.5 86.9 86.1 87.8 87.6 90.1 90.5 90.4 90.3 91.4 91.4 92.4 92.2 93.0 92.7 93.6 93.7 93.6 93.7 94.1 94.1 94.5 94.7 95.0 94.9 95.4 95.2 94.5 94.2 95.4 95.2 95.8 95.5 95.0 94.9 95.0 94.8 96.2 96.2 96.2 96.0 96.2 96.0 70.4 74.4 77.6 79.8 80.6 82.6 83.5 85.9 89.5 88.9 90.2 91.0 91.4 93.1 93.2 93.1 94.0 95.0 94.2 93.0 94.2 94.4 94.1 93.8 95.6 95.1 95.2 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.77 0.53 5.8 1.38 2.4 3.2 0.0009 0.73 0.81 6.9 2.02 3.1 4.0 0.00122 0.78 1.1 8.0 3.3 3.5 4.3 0.0028 0.76 1.45 8.8 4.05 3.3 4.9 0.0033 0.75 2.2 9.3 6.02 3.7 4.6 0.007 0.73 3.02 8.8 8.21 4.1 4.9 0.007 0.78 4.07 9.3 11.9 3.6 4.8 0.011 0.83 5.17 9.1 16.4 3.1 4.2 0.014 0.75 7.43 9.3 21.7 3.5 4.9 0.018 0.79 9.67 7.5 29.7 2.4 3.8 0.031 0.76 13.6 7.7 40.5 2.7 3.9 0.037 0.82 18.2 8.7 59.1 2.9 4.2 0.11 0.82 24.7 9.5 80.5 3.3 4.1 0.135 0.82 30.3 8.4 99 3.1 3.5 0.219 0.82 35.8 9.3 117 3.3 3.7 0.243 0.84 47.7 8.2 161 2.8 3.9 0.385 0.83 59.3 8.8 198 3.6 3.5 0.427 0.83 71.8 8.8 241.2 2.9 4.7 0.525 0.83 87.5 7.9 294.3 3.2 4.4 0.694 0.84 117 7.4 401 2.5 3.1 1.38 0.85 139 8.2 481 2.7 3.2 1.73 0.84 172 7.9 587 2.2 3.3 2.43 0.85 204 7.6 705 2.4 3.2 2.9 0.85 246 7.8 854 2.4 3.3 3.2 0.86 305 7.8 1068 2.6 3.3 3.9 0.87 494 7.5 1679 2.2 3.5 6.9 0.86 541 7.2 1893 2.4 3.1 7.2 Weight kg Sound pressure Level LPA dB 11 48 15 48 20 48 22 53 28 53 32 53 38 57 42 66 52 67 68 69 78 66 160 68 179 67 215 68 229 67 292 69 322 65 357 72 406 73 645 77 700 78 930 74 1000 74 1065 74 1220 77 1780 81 1820 81 Output kW Motor type Product code 1800 r/min = 4 poles 18.5 4) M3BP 160MLC 4 3GBP162430-··L 30 M3BP 180MLC 4 3GBP182430-··L 37 M3BP 200MLB 4 3GBP202420-··L 55 4) M3BP 225SMC 4 3GBP222230-··L 75 M3BP 250SMB 4 3GBP252220-··L 110 M3BP 280SMD 4 3GBP282240-··L 132 4) M3BP 280MLA 4 3GBP282410-··L 160 4) M3BP 280MLB 4 3GBP282420-··L 280 4) M3BP 315LKB 4 3GBP312820-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1777 1780 1783 1782 1784 1788 1785 1786 1789 460 V 60 Hz 92.4 92.6 94.3 94.5 94.5 94.9 94.1 94.4 95.4 95.4 95.8 95.9 95.7 95.7 96.0 96.0 95.8 95.6 91.5 93.9 94.4 93.6 94.6 95.3 95.4 95.4 94.9 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.80 31.2 9.2 99.4 3.3 3.9 0.124 0.81 49 8.5 161 2.9 3.7 0.191 0.82 59.9 8.6 198 3.1 3.3 0.362 0.84 86.7 8.7 295 3.4 3.6 0.536 0.84 117 9.1 401 3.6 4.0 0.941 0.84 171 8.4 588 2.9 3.3 1.95 0.86 202 8.1 705 2.9 3.1 2.3 0.86 242 9.1 855 3.1 3.2 2.5 0.84 437 9.2 1494 3.2 3.4 5 Weight kg Sound pressure Level LPA dB 180 71 235 65 305 68 391 75 464 77 750 80 840 78 890 78 1520 81 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2 48 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 460 V 60 Hz IE3 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1200 r/min = 6 poles 0.75 M3BP 90SLD 6 3GBP093040-··L 1.1 3) M3BP 90LF 6 3GBP093560-··L 1.5 3) M3BP 100MLB 6 3GBP103420-··L 2.2 4) M3BP 112MJ 6 3GBP113390-··L 3 4) M3BP 132SMB 6 3GBP133220-··L 4 4) M3BP 132SMF 6 3GBP133260-··L 5.5 M3BP 132SMJ 6 3GBP133290-··L 7.5 M3BP 160MLA 6 3GBP163410-··L 11 M3BP 160MLB 6 3GBP163420-··L 15 M3BP 180MLA 6 3GBP183410-··L 18.5 M3BP 200MLA 6 3GBP203410-··L 22 M3BP 200MLB 6 3GBP203420-··L 30 4) M3BP 225SMA 6 3GBP223210-··L 37 M3BP 250SMA 6 3GBP253210-··L 45 M3BP 280SMB 6 3GBP283220-··L 55 M3BP 280SMC 6 3GBP283230-··L 75 M3BP 315SMB 6 3GBP313220-··L 90 M3BP 315SMC 6 3GBP313230-··L 110 4) M3BP 315SMD 6 3GBP313240-··L 132 M3BP 315MLB 6 3GBP313420-··L 160 M3BP 355SMA 6 3GBP353210-··L 200 M3BP 355SMB 6 3GBP353220-··L 250 M3BP 355SMC 6 3GBP353230-··L 315 M3BP 355MLB 6 3GBP353420-··L 355 M3BP 355LKA 6 3GBP353810-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1152 1152 1165 1164 1174 1182 1176 1179 1179 1182 1190 1191 1190 1191 1192 1193 1195 1195 1194 1196 1193 1193 1194 1194 1194 460 V 60 Hz 82.5 82.4 75.0 76.2 85.2 85.0 88.5 88.1 87.5 86.5 87.5 86.6 91.0 91.4 91.0 91.3 91.7 92.0 91.7 91.9 93.0 92.9 93.0 92.8 93.5 93.3 94.1 94.2 94.5 94.3 94.5 94.5 95.0 94.7 95.0 94.9 95.0 94.8 95.8 95.5 95.8 95.8 95.8 95.8 95.8 95.8 95.8 95.8 95.8 95.7 80.1 74.4 82.9 86.0 83.9 84.4 90.6 90.6 91.2 91.0 91.8 91.4 92.1 94.8 93.1 93.5 93.6 93.8 93.7 94.4 95.1 95.2 95.1 95.1 94.9 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.75 1.6 5.2 6.2 2.3 3.3 0.0056 0.73 2.5 5.5 9.09 2.3 3.3 0.0068 0.65 3.4 6.1 12.3 2.9 4.0 0.012 0.67 4.84 6.8 18 2.5 3.9 0.0196 0.58 7.5 7.3 24.2 2.9 4.3 0.0355 0.58 9.9 7.3 32.3 2.9 4.3 0.0416 0.62 10.5 6.0 44.6 2.0 3.1 0.0408 0.77 13.5 6.7 60.7 1.4 3.8 0.089 0.76 19.8 7.2 89.1 1.9 3.6 0.138 0.78 26.1 5.7 122 1.6 3.1 0.212 0.82 30.6 7.5 149 2.6 3.7 0.496 0.81 36.7 8.3 177 3.1 4.2 0.585 0.77 52.6 8.7 241 3.5 4.3 0.724 0.80 61.8 7.4 297 2.7 4.4 1.3 0.83 72 8.4 360 2.9 3.3 1.87 0.84 87 8.6 441 3.0 3.3 2.57 0.84 118 7.7 600 2.0 2.9 4.1 0.84 143 8.2 720 2.2 3.3 4.6 0.83 175 8.3 880 2.4 3.4 4.9 0.82 211 8.3 1055 2.5 3.5 6.3 0.82 257 7.6 1281 2.6 2.8 7.9 0.82 320 7.7 1600 2.8 2.7 9.7 0.81 408 8.8 2000 3.2 3.4 11.3 0.83 495 7.9 2521 2.8 3.6 13.5 0.80 579 8.6 2840 3.2 3.6 15.5 Weight kg Sound pressure Level LPA dB 29 56 33 47 41 52 53 69 75 60 82 60 81 57 146 68 180 67 212 69 272 68 297 68 349 67 431 69 645 75 725 74 930 78 1000 79 1040 78 1200 72 1520 78 1680 78 1820 78 2180 79 2500 76 Output kW Motor type Product code 1200 r/min = 6 poles 18.5 M3BP 180MLB 6 3GBP183420-··L 37 M3BP 225SMB 6 3GBP223220-··L 45 M3BP 250SMB 6 3GBP253220-··L 55 M3BP 250SMC 6 3GBP253230-··L 75 4) M3BP 280SMD 6 3GBP283240-··L 160 M3BP 315LKA 6 3GBP313810-··L 180 M3BP 315LKB 6 3GBP313820-··L 200 M3BP 315LKC 6 3GBP313830-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1183 1188 1192 1191 1192 1195 1195 1194 460 V 60 Hz 93.0 93.0 94.1 94.4 94.5 94.5 94.5 94.7 94.8 94.7 95.8 95.6 95.8 95.6 96.1 96.1 91.9 93.8 93.5 94.0 93.8 94.6 94.8 95.5 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.73 34.2 7.4 149 2.5 3.5 0.22 0.80 61.8 8.0 297 3.0 3.3 0.813 0.80 75 8.6 361 3.2 3.6 1.5 0.81 90.1 8.2 441 3.3 3.5 1.49 0.85 116 8.7 601 3.1 3.3 3 0.81 259 8.5 1279 2.5 3.5 7.3 0.82 287 8.7 1438 2.6 3.4 8.3 0.81 322 8.0 1599 2.5 3.1 9.2 Weight kg Sound pressure Level LPA dB 219 69 382 72 465 72 466 72 740 76 1410 79 1520 79 1600 79 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2 ABB Motors and Generators | 9AKK105944 EN 02-2020 49 Technical data, 400 V 50 Hz IE4 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE4 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3000 r/min = 2 poles 11 M3BP 160MLA 2 3GBP161410-··M 15 M3BP 160MLB 2 3GBP161420-··M 18.5 M3BP 160MLC 2 3GBP161430-··M 22 M3BP 180MLA 2 3GBP181410-··M 30 M3BP 200MLA 2 3GBP201410-··M 37 M3BP 200MLB 2 3GBP201420-··M 45 M3BP 225SMA 2 3GBP221210-··M 55 M3BP 250SMA 2 3GBP251210-··M 75 M3BP 280SMB 2 3GBP281220-··M 90 M3BP 280SMC 2 3GBP281230-··M 110 M3BP 315SMB 2 3GBP311220-··M 132 M3BP 315SMC 2 3GBP311230-··M 160 M3BP 315MLA 2 3GBP311410-··M 200 M3BP 315MLB 2 3GBP311420-··M 200 1) M3BP 355SMA 2 3GBP351210-··M 250 M3BP 315LKB 2 3GBP311820-··M 250 1) M3BP 355SMB 2 3GBP351220-··M 315 1) M3BP 355SMC 2 3GBP351230-··M 355 1) M3BP 355MLA 2 3GBP351410-··M 400 1) M3BP 355MLB 2 3GBP351420-··M 450 1) M3BP 355MLC 2 3GBP351430-··M 500 1) M3BP 355LKA 2 3GBP351810-··M 560 2) M3BP 400LA 2 3GBP401510-··M 630 2) M3BP 400LB 2 3GBP401520-··M 710 2) M3BP 400LC 2 3GBP401530-··M 800 2)3) M3BP 450LA 2 3GBP451510-··M 900 2)3) M3BP 450LB 2 3GBP451520-··M Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 2953 2955 2943 2960 2957 2955 2971 2976 2980 2981 2982 2986 2983 2983 2985 2982 2983 2984 2981 2982 2983 2982 2988 2987 2987 2990 2990 400 V 50 Hz 92.6 92.9 93.3 93.5 93.7 94.4 94.0 94.3 94.5 94.8 94.8 95.4 95.0 95.2 95.3 95.5 95.6 95.6 95.8 95.6 96.0 96.0 96.2 96.3 96.3 96.5 96.5 96.8 96.5 96.2 96.5 96.8 96.5 96.6 96.5 96.5 96.5 96.7 96.5 96.2 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.2 96.5 96.3 96.5 96.2 96.5 96.2 92.4 93.0 94.5 94.1 94.9 95.4 94.5 95.2 94.9 95.0 95.3 95.9 96.3 96.7 95.4 96.8 96.2 95.9 96.3 95.5 95.7 96.0 95.7 95.6 95.7 95.4 95.5 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.88 19.5 8.3 35.6 3.3 4.1 0.0514 0.88 26.5 9.0 48.5 3.8 4.4 0.0612 0.90 31.9 8.6 60.7 3.3 4.0 0.079 0.88 38.4 8.5 71.5 2.7 3.5 0.126 0.91 50.5 7.3 96.9 2.1 3.0 0.196 0.89 63.7 7.5 121 2.7 3.7 0.217 0.88 77.5 8.0 145 3.4 3.6 0.323 0.88 94.4 8.4 178 3.3 3.6 0.634 0.87 129 7.3 240 2.5 2.9 0.9 0.88 153 8.0 288 3.0 3.1 1.15 0.88 189 6.7 352 1.9 2.6 1.4 0.88 226 7.9 422 2.4 3.0 1.7 0.90 268 7.3 512 2.2 2.7 2.1 0.90 333 6.8 640 1.9 2.6 2.2 0.90 336 7.6 640 2.0 3.1 3 0.91 413 7.9 800 2.5 2.7 2.9 0.90 415 7.6 800 2.2 3.0 3.4 0.89 533 7.8 1008 2.3 2.8 3.6 0.90 595 7.5 1137 2.3 2.6 4.1 0.88 677 7.1 1280 2.3 2.9 4.1 0.90 743 7.9 1440 2.2 2.9 4.3 0.90 827 7.5 1601 2.0 3.9 4.8 0.89 934 7.8 1789 2.5 3.7 7.9 0.89 1049 7.6 2014 2.6 3.7 8.2 0.89 1178 7.2 2270 2.6 3.4 9.3 0.87 1362 7.8 2555 1.3 3.4 12.2 0.87 1534 7.6 2874 1.5 3.1 13.5 Weight kg Sound pressure Level LPA dB 140.6 69 169.8 69 179 67 224 67 289.1 72 309 72 395 74 483 75 665 77 725 77 940 77 1025 77 1190 77 1220 77 1600 83 1540 77 1680 83 1750 83 2000 83 2000 83 2080 83 2320 83 2950 82 2950 82 3050 82 4000 85 4000 85 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class 3 50 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE4 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE4 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1500 r/min = 4 poles 11 M3BP 160MLA 4 3GBP162410-··M 15 M3BP 160MLB 4 3GBP162420-··M 18.5 M3BP 180MLA 4 3GBP182410-··M 22 M3BP 180MLB 4 3GBP182420-··M 30 M3BP 200MLA 4 3GBP202410-··M 37 M3BP 225SMA 4 3GBP222210-··M 45 M3BP 225SMB 4 3GBP222220-··M 55 M3BP 250SMA 4 3GBP252210-··M 75 M3BP 280SMC 4 3GBP282230-··M 90 M3BP 280MLA 4 3GBP282410-··M 110 M3BP 315SMC 4 3GBP312230-··M 132 M3BP 315SMD 4 3GBP312240-··M 160 M3BP 315MLB 4 3GBP312420-··M 200 M3BP 315LKB 4 3GBP312820-··M 200 M3BP 355SMA 4 3GBP352210-··M 250 M3BP 315LKC 4 3GBP312830-··M 250 M3BP 355SMB 4 3GBP352220-··M 315 M3BP 355SMC 4 3GBP352230-··M 355 M3BP 355MLA 4 3GBP352410-··M 400 M3BP 355MLB 4 3GBP352420-··M 450 M3BP 355MLC 4 3GBP352430-··M 500 M3BP 355LKA 4 3GBP352810-··M 630 M3BP 400LB 4 3GBP402520-··M 800 M3BP 450LA 4 3GBP452510-··M 900 M3BP 450LB 4 3GBP452520-··M Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1477 1478 1482 1479 1486 1480 1478 1483 1487 1489 1491 1490 1490 1490 1491 1490 1491 1490 1491 1490 1489 1490 1491 1491 1491 400 V 50 Hz 93.3 93.4 93.9 94.1 94.2 94.2 94.5 95.0 94.9 94.9 95.2 95.7 95.4 96.0 95.7 95.8 96.0 96.4 96.1 96.5 96.3 96.5 96.4 96.6 96.6 96.8 96.7 96.9 96.7 96.8 96.7 96.9 96.7 96.8 96.7 96.8 96.7 96.9 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.5 92.9 93.2 93.5 94.9 94.2 95.6 96.2 95.4 96.1 96.4 96.1 96.2 96.4 96.8 96.4 96.8 96.5 96.5 96.5 96.3 96.5 96.1 96.2 96.2 96.0 Current Power factor IN Cosj A IS/IN B-design 0.79 21.6 7.6 0.76 30.6 8.3 0.83 34.2 8.6 0.82 41 6.7 0.76 60.2 8.7 0.84 66.9 7.5 0.85 80.8 7.3 0.83 100 7.8 0.86 130 7.8 0.85 160 8.8 0.85 194 7.8 0.85 234 7.9 0.87 278 7.9 0.87 346 7.6 0.87 345 7.3 0.87 432 7.8 0.87 433 7.8 0.86 554 7.4 0.87 616 7.9 0.85 700 6.8 0.86 779 6.8 0.86 865 6.8 0.86 1091 7.6 0.86 1388 7.0 0.85 1575 7.0 Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 71.1 2.7 3.7 0.123 98.4 3.5 3.9 0.127 121 3.0 3.8 0.191 142 2.1 2.7 0.188 194 4.1 4.2 0.369 239 3.1 3.2 0.536 291 2.5 2.9 0.536 354 3.3 3.5 0.933 481 2.8 2.9 1.85 577 3.4 3.2 2.3 704 2.4 3.1 2.9 846 2.6 3.2 3.2 1026 2.7 3.0 3.9 1282 2.5 2.9 5 1282 2.1 2.7 5.9 1601 2.3 3.0 5.5 1601 2.5 2.9 6.9 2017 2.8 2.9 7.2 2274 2.7 2.9 8.4 2563 2.1 2.8 8.4 2886 2.4 2.8 8.4 3204 2.0 3.0 10 4034 2.2 2.9 16 5121 1.3 2.8 23 5761 1.3 2.8 25 Weight kg Sound pressure Level LPA dB 188 62 175 62 226 62 231.6 62 304 63 383 66 402.6 66 467 67 725 72 840 72 1000 68 1065 68 1220 68 1480 74 1610 74 1600 74 1780 74 1820 74 2140 78 2140 78 2140 78 2500 78 3300 78 4050 85 4050 85 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class 3 Output kW Motor type 1500 r/min = 4 poles 560 3) M3BP 400LA 4 710 3) M3BP 400LC 4 1000 3) M3BP 450LC 4 Product code 3GBP402510-··M 3GBP402530-··M 3GBP452530-··M Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 1491 96.7 96.7 96.3 1491 96.7 96.7 96.2 1491 96.7 96.7 96.1 Current Power factor IN Cosj A IS/IN F-design 0.85 982 7.4 0.84 1227 7.6 0.86 1724 6.8 Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 3586 2.4 2.8 15 4547 2.4 3.0 17 6404 1.3 2.7 30 Weight kg Sound pressure Level LPA dB 3200 78 3300 78 4350 85 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class 3 ABB Motors and Generators | 9AKK105944 EN 02-2020 51 Technical data, 400 V 50 Hz IE4 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE4 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1000 r/min = 6 poles 7.5 M3BP 160MLA 6 3GBP163410-··M 11 M3BP 160MLB 6 3GBP163420-··M 15 M3BP 180MLA 6 3GBP183410-··M 18.5 M3BP 200MLA 6 3GBP203410-··M 22 M3BP 200MLB 6 3GBP203420-··M 30 M3BP 225SMA 6 3GBP223210-··M 37 M3BP 250SMA 6 3GBP253210-··M 45 M3BP 280SMB 6 3GBP283220-··M 55 M3BP 280SMC 6 3GBP283230-··M 75 M3BP 315SMC 6 3GBP313230-··M 90 M3BP 315SMD 6 3GBP313240-··M 110 M3BP 315MLB 6 3GBP313420-··M 132 M3BP 315LKA 6 3GBP313810-··M 160 M3BP 315LKC 6 3GBP313830-··M 160 M3BP 355SMB 6 3GBP353220-··M 200 M3BP 355SMC 6 3GBP353230-··M 250 M3BP 355MLB 6 3GBP353420-··M 315 M3BP 355LKA 6 3GBP353810-··M 355 M3BP 355LKB 6 3GBP353820-··M 400 M3BP 400LA 6 3GBP403510-··M 450 M3BP 400LB 6 3GBP403520-··M 500 M3BP 400LC 6 3GBP403530-··M 560 M3BP 400LD 6 3GBP403540-··M 630 M3BP 450LA 6 3GBP453510-··M 710 M3BP 450LB 6 3GBP453520-··M 800 3) M3BP 450LC 6 3GBP453530-··M Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 984 91.3 91.0 89.4 980 92.3 92.3 91.7 985 92.9 92.8 91.8 991 93.4 94.1 93.6 986 93.7 94.0 94.0 988 94.2 94.5 94.1 989 94.5 94.9 94.8 992 94.8 95.1 94.6 990 95.1 95.4 95.1 994 95.4 95.6 95.2 994 95.6 95.8 95.4 994 95.8 96.0 95.8 993 96.0 96.2 96.0 994 96.2 96.4 96.3 995 96.2 96.2 95.7 995 96.3 96.5 96.1 995 96.5 96.7 96.6 994 96.6 96.7 96.5 995 96.7 96.7 96.3 993 96.6 96.7 96.4 993 96.6 96.7 96.4 994 96.6 96.5 95.8 993 96.6 96.6 96.1 995 96.6 96.6 95.9 995 96.6 96.7 96.1 995 96.6 96.6 96.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.75 15.7 7.1 72.8 1.8 3.6 0.133 0.76 22.8 7.3 109 1.9 3.4 0.133 0.72 32.6 7.4 147 2.8 3.8 0.254 0.81 35.2 7.8 178 2.3 3.5 0.448 0.81 42.4 6.9 216 2.5 3.1 0.531 0.78 59.2 7.3 290 3.0 3.4 0.813 0.81 69.4 6.8 357 2.1 2.8 1.49 0.85 80.9 6.9 434 2.4 2.6 2.2 0.85 99.4 6.8 506 2.4 2.6 2.85 0.83 138 7.0 721 2.2 2.8 4.9 0.81 170 7.2 864 2.4 2.9 4.9 0.83 202 6.9 1057 2.3 2.7 6.3 0.82 243 6.9 1269 2.4 2.7 7.3 0.82 297 7.4 1537 2.7 2.9 9.2 0.82 294 7.0 1536 2.1 2.7 9.7 0.82 367 7.3 1920 2.3 2.8 11.3 0.83 456 7.1 2399 2.3 2.7 13.5 0.83 576 6.9 3026 2.3 2.6 15.5 0.81 668 7.7 3407 2.7 2.9 16.5 0.82 729 7.4 3846 2.5 2.6 17 0.82 820 7.0 4327 2.4 2.4 18.6 0.83 900 8.0 4803 2.6 3.1 22 0.85 984 7.4 5386 2.4 2.8 24 0.82 1146 7.5 6046 1.4 3.2 31 0.85 1244 7.0 6814 1.3 2.5 37 0.84 1415 7.2 7677 1.3 2.7 41 Weight kg Sound pressure Level LPA dB 186.9 59 189 59 240 59 291 63 306 63 369 63 457 63 680 65 725 65 1000 67 1040 67 1200 68 1410 68 1600 68 1680 73 1820 73 2180 73 2500 76 2600 76 2900 76 2990 76 3300 76 3400 77 4150 81 4500 81 4800 81 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class 3 52 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 460 V 60 Hz IE4 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE4 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3600 r/min = 2 poles 11 M3BP 160MLA 2 3GBP161410-··M 15 M3BP 160MLB 2 3GBP161420-··M 18.5 M3BP 160MLC 2 3GBP161430-··M 22 M3BP 180MLA 2 3GBP181410-··M 30 M3BP 200MLA 2 3GBP201410-··M 37 M3BP 200MLB 2 3GBP201420-··M 45 M3BP 225SMA 2 3GBP221210-··M 55 M3BP 250SMA 2 3GBP251210-··M 75 M3BP 280SMB 2 3GBP281220-··M 90 M3BP 280SMB 2 3GBP281230-··M 110 M3BP 315SMB 2 3GBP311220-··M 155 M3BP 315SMC 2 3GBP311230-··M 200 M3BP 315MLB 2 3GBP311420-··M 200 1) M3BP 355SMA 2 3GBP351210-··M 250 M3BP 315LKB 2 3GBP311820-··M 250 1) M3BP 355SMB 2 3GBP351220-··M 315 1) M3BP 355SMC 2 3GBP351230-··M 355 1) M3BP 355MLA 2 3GBP351410-··M 400 1) M3BP 355MLB 2 3GBP351420-··M 450 1)3) M3BP 355MLC 2 3GBP351430-··M 500 1) M3BP 355LKA 2 3GBP351810-··M 560 2) M3BP 400LA 2 3GBP401510-··M 630 2)3) M3BP 400LA 2 3GBP401510-··M 710 2)3) M3BP 400LB 2 3GBP401520-··M 780 2)3) M3BP 400LC 2 3GBP401530-··M 800 2)3) M3BP 450LA 2 3GBP451510-··M 900 2)3) M3BP 450LB 2 3GBP451520-··M Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 3558 3559 3555 3564 3562 3560 3575 3579 3582 3582 3598 3583 3584 3586 3583 3585 3586 3583 3582 3585 3584 3588 3588 3587 3587 3591 3591 460 V 60 Hz 92.4 92.4 92.4 92.3 93.0 93.2 93.0 93.0 93.6 93.8 94.1 94.2 94.5 94.1 94.5 94.3 95.0 94.6 95.4 95.0 95.4 94.9 95.8 95.5 96.2 96.2 96.2 95.8 96.2 96.2 96.2 95.8 96.2 95.8 96.2 95.9 96.2 95.6 96.2 95.8 96.2 95.9 96.2 95.8 96.2 95.9 96.2 95.9 96.2 95.9 96.2 95.9 96.2 95.9 91.1 91.1 92.6 92.0 93.4 93.6 92.9 93.2 93.3 93.8 93.5 94.7 95.5 94.8 95.8 94.8 94.8 94.9 94.3 94.8 95.0 94.5 94.7 94.7 94.8 94.7 95.1 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.90 16.6 9.9 29.5 3.1 4.5 0.0514 0.90 22.5 10.8 40.2 3.6 4.8 0.0612 0.89 27.9 9.7 50.4 4.0 4.8 0.079 0.87 33.4 9.5 59.3 3.7 4.4 0.126 0.91 43.9 8.3 80.4 2.3 3.3 0.196 0.89 55.1 8.5 99.2 3.1 4.5 0.217 0.87 67.7 9.2 120 3.7 4.1 0.323 0.89 82.5 9.2 148 3.7 4.0 0.634 0.87 113 8.2 200 2.5 3.2 0.9 0.88 133 9.0 240 3.4 3.4 1.15 0.88 165 7.5 293 1.9 2.9 1.4 0.89 228 7.7 413 2.1 2.8 1.7 0.90 290 7.7 533 2.0 2.9 2.2 0.88 295 8.5 533 2.0 3.4 3 0.91 359 9.0 666 2.6 3.0 2.9 0.90 363 8.5 666 2.3 3.3 3.4 0.89 466 8.7 839 2.3 3.1 3.6 0.90 518 8.5 944 2.3 2.9 4.1 0.88 589 8.3 1066 2.3 3.2 4.1 0.90 650 8.9 1199 2.2 3.2 4.3 0.90 722 9.0 1332 2.4 4.3 4.8 0.89 818 9.0 1490 2.3 3.8 7.9 0.89 914 7.9 1676 2.0 3.5 7.9 0.89 1029 7.9 1890 2.1 3.4 8.2 0.90 1116 8.2 2076 2.5 3.5 9.3 0.87 1188 8.0 2127 1.3 3.5 12.2 0.85 1366 7.8 2393 1.5 3.4 13.5 Weight kg Sound pressure Level LPA dB 141 73 170 73 179 71 224 71 289 76 309 76 395 78 483 79 665 80 725 80 940 80 1025 82 1220 80 1600 86 1540 80 1680 86 1750 86 2000 86 2000 88 2080 88 2320 88 2950 86 2950 86 2950 86 3050 86 4000 90 4000 90 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class 3 ABB Motors and Generators | 9AKK105944 EN 02-2020 53 Technical data, 460 V 60 Hz IE4 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE4 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1800 r/min = 4 poles 11 M3BP 160MLA 4 3GBP162410-··M 15 M3BP 160MLB 4 3GBP162420-··M 18.5 M3BP 180MLA 4 3GBP182410-··M 22 M3BP 180MLB 4 3GBP182420-··M 30 M3BP 200MLA 4 3GBP202410-··M 37 M3BP 225SMA 4 3GBP222210-··M 45 M3BP 225SMB 4 3GBP222220-··M 55 M3BP 250SMA 4 3GBP252210-··M 75 M3BP 280SMC 4 3GBP282230-··M 90 M3BP 280MLA 4 3GBP282410-··M 110 M3BP 315SMC 4 3GBP312230-··M 132 M3BP 315SMD 4 3GBP312240-··M 160 M3BP 315MLB 4 3GBP312420-··M 200 M3BP 355SMA 4 3GBP352210-··M 250 M3BP 355SMB 4 3GBP352220-··M 315 M3BP 355SMC 4 3GBP352230-··M 355 M3BP 355MLA 4 3GBP352410-··M 400 M3BP 355MLB 4 3GBP352420-··M 450 M3BP 355MLB 4 3GBP352420-··M 450 M3BP 355MLC 4 3GBP352430-··M 500 M3BP 355MLC 4 3GBP352430-··M 500 M3BP 355LKA 4 3GBP352810-··M 560 4) M3BP 400LA 4 3GBP402510-··M 630 M3BP 400LB 4 3GBP402520-··M 710 3) M3BP 400LC 4 3GBP402530-··M 800 4) M3BP 450LA 4 3GBP452510-··M 900 M3BP 450LB 4 3GBP452520-··M 1000 3) M3BP 450LC 4 3GBP452530-··M Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1780 1782 1781 1782 1789 1784 1782 1785 1787 1790 1792 1791 1791 1792 1792 1791 1792 1791 1790 1791 1789 1791 1792 1793 1792 1792 1792 1792 460 V 60 Hz 93.6 93.5 94.1 93.9 94.5 94.7 94.5 95.0 95.0 94.7 95.4 95.5 95.4 95.7 95.8 95.0 96.2 96.1 96.2 96.2 96.2 96.0 96.5 96.3 96.5 96.5 96.5 96.2 96.8 96.6 96.8 96.6 96.8 96.6 96.8 96.7 96.8 96.7 96.8 96.7 96.8 96.8 96.8 96.3 96.2 96.0 96.8 96.6 96.8 96.6 96.7 96.5 96.8 96.3 96.8 96.6 92.5 92.6 93.9 94.8 93.7 95.1 95.5 94.1 95.3 95.4 95.3 95.6 95.9 95.4 96.0 96.1 96.0 96.1 96.3 96.2 96.3 95.2 95.3 95.9 96.0 96.0 96.0 95.8 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.77 19.2 8.6 59 3.0 4.2 0.123 0.75 27 9.5 81.7 3.8 4.6 0.127 0.82 29.9 9.2 100 3.2 4.3 0.191 0.82 35.3 7.7 118 2.3 3.1 0.188 0.74 53.3 9.5 160 4.3 4.9 0.369 0.83 58.6 8.6 198 3.4 3.5 0.536 0.83 71.1 8.4 241 2.8 3.2 0.536 0.81 88.3 7.9 294 3.8 4.0 0.933 0.84 116 8.9 400 3.0 3.2 1.85 0.84 136 9.8 481 3.6 3.5 2.3 0.83 172 8.8 586 2.6 3.4 2.9 0.84 206 9.0 704 2.8 3.6 3.2 0.86 241 9.0 853 2.9 3.3 3.9 0.87 301 8.3 1065 2.2 3.0 5.9 0.86 381 8.8 1332 2.7 3.2 6.9 0.85 479 8.5 1679 3.1 3.2 7.2 0.86 542 9.0 1890 2.9 3.2 8.4 0.85 609 8.5 2132 2.6 3.2 8.4 0.86 677 7.6 2400 2.2 2.8 8.4 0.85 685 8.2 2399 2.5 3.1 8.4 0.85 761 7.4 2669 2.2 2.8 8.4 0.85 763 8.0 2666 2.4 3.4 10 0.84 863 7.8 2985 2.7 3.1 15 0.85 960 8.9 3355 2.2 3.3 16 0.84 1091 7.9 3784 2.5 3.3 17 0.85 1222 6.5 4263 1.3 3.1 23 0.85 1373 7.9 4794 1.3 3.1 25 0.86 1505 7.2 5329 1.4 2.8 30 Weight kg Sound pressure Level LPA dB 188 66 175 66 226 66 232 66 304 67 383 70 403 72 467 71 725 72 840 75 1000 71 1065 71 1220 71 1610 77 1780 77 1820 77 2140 81 2140 82 2140 82 2140 82 2140 82 2500 83 3200 83 3300 83 3300 83 4050 89 4050 89 4350 89 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class 3 54 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 460 V 60 Hz IE4 cast iron motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE4 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1200 r/min = 6 poles 7.5 4) M3BP 160MLA 6 3GBP163410-··M 11 M3BP 160MLB 6 3GBP163420-··M 15 M3BP 180MLA 6 3GBP183410-··M 18.5 M3BP 200MLA 6 3GBP203410-··M 22 M3BP 200MLB 6 3GBP203420-··M 30 M3BP 225SMA 6 3GBP223210-··M 37 M3BP 250SMA 6 3GBP253210-··M 45 4) M3BP 280SMB 6 3GBP283220-··M 55 4) M3BP 280SMC 6 3GBP283230-··M 90 M3BP 315SMD 6 3GBP313240-··M 110 M3BP 315MLB 6 3GBP313420-··M 132 M3BP 315LKA 6 3GBP313810-··M 160 M3BP 315LKC 6 3GBP313830-··M 160 M3BP 355SMB 6 3GBP353220-··M 200 M3BP 355SMC 6 3GBP353230-··M 250 M3BP 355MLB 6 3GBP353420-··M 315 M3BP 355LKA 6 3GBP353810-··M 355 M3BP 355LKB 6 3GBP353820-··M 400 M3BP 400LA 6 3GBP403510-··M 450 M3BP 400LA 6 3GBP403510-··M 500 4) M3BP 400LC 6 3GBP403530-··M 560 4) M3BP 400LC 6 3GBP403530-··M 630 3) M3BP 400LD 6 3GBP403540-··M 710 M3BP 450LA 6 3GBP453510-··M 710 M3BP 450LB 6 3GBP453520-··M 800 M3BP 450LC 6 3GBP453530-··M 900 3) M3BP 450LC 6 3GBP453530-··M Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1186 1184 1186 1192 1189 1190 1191 1193 1190 1195 1194 1194 1195 1195 1196 1195 1195 1195 1194 1193 1195 1194 1193 1195 1196 1195 1195 460 V 60 Hz 91.3 90.6 93.0 93.5 93.0 92.7 94.1 94.1 94.1 93.8 95.0 94.9 95.0 94.8 95.3 95.2 95.3 95.3 95.8 95.6 96.2 96.0 96.2 96.0 96.2 96.0 96.2 96.0 96.2 95.7 96.5 96.5 96.5 96.5 96.5 96.2 96.5 96.4 96.5 96.6 96.4 96.0 96.5 96.3 96.5 96.5 96.5 96.3 96.5 96.2 96.5 96.4 96.6 96.6 88.3 92.8 91.1 93.4 93.4 94.1 94.5 94.3 94.5 94.9 95.4 95.5 95.3 95.3 95.0 95.8 95.9 95.4 95.9 96.2 95.1 95.5 95.9 95.5 95.5 95.7 96.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.73 14.1 7.8 60.4 1.9 4.0 0.133 0.77 19.2 7.1 88.8 1.7 3.5 0.133 0.79 29.1 7.9 122 2.9 4.4 0.254 0.80 31 8.8 148.3 2.7 4.0 0.448 0.80 37.1 8.1 178.6 3.0 3.5 0.531 0.75 52.6 7.7 242.6 1.5 1.8 0.813 0.80 61.3 7.7 297 2.4 3.1 1.49 0.85 70.6 7.9 361 2.6 2.9 2.2 0.85 86.2 7.8 420 2.6 2.9 2.85 0.80 149 8.2 719 2.7 3.2 4.9 0.81 177 7.9 880 2.6 3.0 6.3 0.81 215 7.9 1055 2.7 3.0 7.3 0.81 259 8.4 1279 3.0 3.2 9.2 0.81 260 7.9 1278 2.3 3.0 9.7 0.82 320 8.3 1598 2.5 3.1 11.3 0.82 401 9.2 1997 2.3 3.0 13.5 0.83 500 7.9 2516 2.6 2.9 15.5 0.80 584 8.8 2835 3.0 3.2 16.5 0.81 642 8.1 3199 2.5 2.9 17 0.83 705 7.3 3602 2.2 2.7 17 0.82 793 8.8 3995 2.6 3.7 22 0.84 867 8.0 4479 2.3 3.3 22 0.86 952 7.5 5042 2.3 2.8 24 0.82 1126 7.1 5674 1.4 3.2 31 0.85 1085 8.2 5671 1.4 2.9 37 0.83 1254 8.4 6393 1.4 3.3 41 0.84 1392 7.2 7191 1.2 2.7 41 Weight kg Sound pressure Level LPA dB 187 63 189 63 240 63 291 67 306 67 369 67 457 67 680 68 725 68 1040 70 1200 71 1410 71 1600 71 1680 76 1820 76 2180 76 2500 79 2600 79 2900 79 2900 79 3300 79 3300 79 3400 79 4150 85 4500 85 4800 85 4800 85 1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1 ABB Motors and Generators | 9AKK105944 EN 02-2020 55 Variant codes Cast iron motors Variant codes specify additional options and features to the standard motor. The desired features are listed as three-digit variant codes in the motor order. Note also that there are variants that cannot be used together. Most of the variant codes apply to IE2, IE3, and IE4 motors. However, confirm the availability of variants for IE3 and IE4 motors with your ABB sales office before making an order. Frame size Code/Variants 71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450 Administration 529 Customer witnessed visual inspection of complete order line. 530 Two-year extension on standard warranty 531 Sea freight packing 533 Wooden sea freight packing 590 Mounting of customer supplied part other than coupling. 683 Prepared for ABB Ability Smart Sensor 684 ABB Ability Smart sensor mounted - - - - - - - - - - - - - Balancing 417 Vibration acc. to Grade B (IEC 60034-14). 423 Balanced without key. 424 Full-key balancing Bearings and Lubrication 036 Transport lock for bearings. 037 Roller bearing at D-end. 039 Cold-resistant grease 040 Heat-resistant grease 041 Bearings regreasable via grease nipples. 043 SPM compatible nipples for vibration measurement 057 2RS bearings at both ends. - - - - - 058 Angular contact bearing at D-end, shaft force away from bearing. 059 Angular contact bearing at N-end, shaft force towards bearing. - - - - - - - - - - - 060 Angular contact bearing at D-end, shaft force towards bearing. - - - - - - - - - - - 061 Angular contact bearing at N-end, shaft force away from bearing. - - - - - - - - - - - 107 Pt100 2-wire in bearings. - - - - - - 128 Double PT100, 2-wire in bearings - - - - - - 129 Double PT100, 3-wire in bearings - - - - - - 130 Pt100 3-wire in bearings. - - - - - - 188 63-series bearing in D-end 194 2Z bearings greased for life at both ends. - - - - - 420 Bearing mounted PTC thermistors. - - - - - - - - - - - 433 Outlet grease collector - - - - - - - - - - - 506 Nipples for vibration measurement : SKF Marlin Quick Connect stud - - - - - - CMSS-2600-3 593 Bearings grease suitable for food and beverage industry. 654 Provision for vibration sensors (M8x1) 795 Lubrication information plate - - - - - - 796 Grease nipples JIS B 1575 PT 1/8 Type A 797 Stainless steel SPM nipples 798 Stainless steel grease nipples 799 Grease nipples flat type DIN 3404, thread M10x1 800 Grease nipples JIS B 1575 PT 1/8" pin type - - - - - - Brakes 517 KFB holding brake 518 SFB-SH holding brake - - - - - - - - - - - - - - - - - - - - - - - - Branch standard designs 142 Manilla connection. - - - - - = Included as standard = Available as option - = Not applicable 56 9AKK105944 EN 02-2020 | ABB Motors and Generators Frame size Code/Variants 71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450 172 Smoke venting specification, 300 ºC, 1 hour, DOL use, class F300 ac- - - - - - - - - - - - cording to EN 12101-3 173 Smoke venting specification, 200 ºC, 2 hours, DOL use, class F200 according to EN 12101-3 - - - - - - - - - - - - 174 Smoke venting specification, 400 ºC, 2 hours, DOL use, class F400 according to EN 12101-3 - - - - - - - - - - - - 177 Design for high ambient applications - - - - - - - - - - - 178 Stainless steel / acid proof bolts. 204 Jacking bolts for foot mounted motors. - - - - - - 209 Non-standard voltage or frequency, (special winding). 386 Smoke venting specification, 200 ºC, 2 hours, VSD use, Class F200 according to EN 12101-3. - - - - - - - - - - - - 387 Smoke venting specification, 300 ºC, 1 hour, VSD use, Class F300 ac- - - - - - - - - - - - cording to EN 12101-3 389 Smoke Venting specification, 400 ºC, 2 hours, VSD use, Class F400 according to EN 12101-3 - - - - - - - - - - - - 392 Smoke Venting specification, 250 ºC, 2 hours, DOL use, Class T250 - - - - - - - - - - - - 393 Smoke venting specification, 250 ºC, 2 hours, VSD use, Class T250 - - - - - - - - - - - - 396 Motor designed for minimum ambient temperature -20 °C to -40 °C, with space heaters (code 450/451 must be added) 397 Motor designed for minimum ambient temperature -40 °C to -55 °C, - - - - - - with space heaters (code 450/451 must be added) 398 Motor designed for minimum ambient temperature -20 °C to -40 °C 399 Motor designed for minimum ambient temperature -40 °C to -55 °C - - - - - - 425 Corrosion protected stator and rotor core. 524 Special run-out tolerances on flange and shaft for close coupled pump applications. - - - - - - - - - - - - - 625 Design for mining applications. - 786 Special design shaft upwards (V3, V36, V6) for outdoor mounting. - - - - - - - - - - - - 877 Design for high ambient applications, motor without fan and fan cover - - - - - - - - - - - Cooling system 044 Unidirectional fan for reduced noise level. Rotation clockwise seen from D-end. Available only for 2-pole motors. - - - - - - - - - - - 045 Unidirectional fan for reduced noise level. Rotation counter clockwise - - - - - - - - - - - seen from D-end. Available only for 2-pole motors. 068 Light alloy metal fan 075 Cooling method IC418 (without fan). 183 Separate motor cooling (fan axial, N-end). 206 Steel fan - 422 Separate motor cooling (on top) with integrated fan motor - - - - - - - - - - - 514 Separate motor cooling (fan on top) - - - - - - - - - - - 791 Stainless steel fan cover - - - - - - - - - Coupling 035 Assembly of customer supplied coupling-half. - - - - - - - - - - - Documentation 141 Binding 2D main dimension drawing. 370 Motor model drawing in 3D 374 Binding 2D motor detailed drawing 536 Photos of manufactured motors 537 Advanced data sheet 722 Rotor dimension drawing (incl. torosional stiffness) 777 Premium documentation package Drain holes 065 Plugged existing drain holes. 448 Draining holes with metal plugs. - - - - - - - - - - - Earthing Bolt 067 External earthing bolt. 525 External earthing bolts on motor feet - Hazardous Environments 456 Ex ec IIC T3 Gc acc. IEC/EN 60079-7 with certificates. - - - - - - - - - - - - - Heating elements 450 Heating element, 100-120 V 451 Heating element, 200 - 240 V = Included as standard = Available as option - = Not applicable ABB Motors and Generators | 9AKK105944 EN 02-2020 57 Frame size Code/Variants 71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450 Insulation system 014 Winding insulation class H. 405 Special winding insulation for frequency converter supply. 406 Winding insulation for supply > 690 <= 1000 volts - - - - - - - - Marine 024 Fulfilling Bureau Veritas (BV) requirements, with certificate. 025 Fulfilling Det Norske Veritas (DNV) requirements, with certificate. 026 Fulfilling Lloyds Register of Shipping (LR) requirements, with certifi- cate. 027 Fulfilling American Bureau of Shipping (ABS) requirements, with certificate. 049 Fulfilling Germanischer Lloyd (GL) requirements, with certificate. 050 Fulfilling Registro Italiano Navale (RINA) requirements, with certificate. 051 Fulfilling Russian Maritime Register of Shipping (RS) requirements, with certificate. 096 Fulfilling Lloyds Register of Shipping (LR) requirements, without certificate (non-essential duty only) 186 Fulfilling Det Norske Veritas (DNV) requirements, without certificate 481 Fulfilling Nippon Kaiji Kyokai (NK) requirements, with certificate. 483 Fulfilling China Classification Societies (CCS) requirements (Beijing), with certificate. 484 Fulfilling Korea Register of Shipping (KR) requirements, with certifi- cate. 491 Fulfilling Nippon Kaiji Kyokai (NK) requirements, without certificate. 492 Fulfilling Registro Italiano Navale (RINA) requirements, without certificate. 493 Fulfilling China Classification Societies (CCS) requirements (Beijing), without certificate. 494 Fulfilling Korea Register of Shipping (KR) requirements, without certificate. 496 Fulfilling Bureau Veritas (BV) requirements, without certificate(non- essential duty only) 497 Fulfilling Russian Maritime Register of Shipping (RS) requirements, - without certificate. 675 Fulfilling American Bureau of Shipping (ABS) requirements, without certificate (non-essential duty only) 676 Fulfilling Germanischer Lloyd (GL) requirements, without certificate (non-essential duty only) Mounting arrangements 008 IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3). - - - - - - - - - - 009 IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). 047 IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5). - - - - - - - - - - 064 NEMA D-flange - - - - - - - - - - - - - - - 066 Modified for specified mounting position differing from IM B3 (1001), IM B5 (3001), B14 (3601), IM B35 (2001), IM B34 (2101) 305 Additional lifting lugs. - - - - - - 320 IM2001 foot/flat bottom flange mounted, from IM1001 (B35 flat bot- - - - - - - - - tom flange from B3) Noise reduction 055 Noise reduction cover for foot mounted motor - - - - - - - - - - - Painting 105 Paint thickness report. 114 Special paint color, standard grade 115 Painting system C4M acc. to ISO 12944-2: 1998. 168 Primer paint only. 303 Painted insulation layer on inside of the terminal boxes. 710 Thermally sprayed zink metallizing with acrylic top coat 711 Painting system C5-M very high, acc. to ISO 12944-5:2007 712 Painting system C5-M according to Petrobras specification. 713 Painting system according Total Egina specification. 754 Painting system C5M acc. to ISO 12944-2:1998 755 Norsok M-501 revision 6, Coating system no. 1 - - - - - - - - - - - - Protection = Included as standard = Available as option - = Not applicable 58 9AKK105944 EN 02-2020 | ABB Motors and Generators Frame size Code/Variants 71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450 005 Protective roof 072 Radial seal at D-end. Not possible for 2-pole , 280 and 315 frames 073 Sealed against oil at D-end. 158 Degree of protection IP65. 211 Weather protected, IP xx W 250 Degree of protection IP66 401 Protective roof, horizontal motor. 403 Degree of protection IP56. 404 Degree of protection IP56, without fan and fan cover. 434 Degree of protection IP56, open deck. 520 Motor protection cover made of glass fiber. Vertical motor, shaft down. 783 Labyrinth sealing at D-end. 784 Gamma-seal at D-end. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Rating & instruction plates 002 Restamping voltage, frequency and output, continuous duty. 004 Additional text on std rating plate (max 12 digits on free text line). 095 Restamping output (maintained voltage, frequency), intermittent duty. 098 Stainless rating plate. - - 126 Tag plate 135 Mounting of additional identification plate, stainless. 138 Mounting of additional identification plate, aluminium. - - - - - - - - - - 139 Additional identification plate delivered loose. 159 Additional plate with text "Made in ...." 160 Additional rating plate affixed. 161 Additional rating plate delivered loose. 163 Frequency converter rating plate. Rating data according to quotation. 181 Rating plate with ABB standard loadability values for VSD operation. Other auxiliaries for VSD operation to be selected as necessary. 332 Baldor Catalogue # - - 333 Not for use in the USA - - 360 Cargotec rating plate - - - - - - 528 Rating plate sticker - - - - - 818 Restamping as generator - - - - - - Shaft & rotor 069 Two shaft extensions according to catalog drawings. 070 Special shaft extension at D-End, standard shaft material 131 Motor delivered with half key (key not exceeding shaft diameter) 155 Cylindrical shaft extension, D-end, without key-way. 164 Shaft extension with closed keyway 165 Shaft extension with open keyway 410 Shaft material stainless steel 591 Special shaft extension according to customer specification. 600 Special shaft extension at N-end, standard shaft material. 630 Shaft material certificate 3.1/3.2 according to EN10204:2004 - - - - - - - - - - - - - - - - Standards and Regulations 010 Fulfilling CSA Safety Certificate. - - - - - - 208 Fulfilling Underwriters Laboratories (UL), listed requirements 252 Shell DEP 33.66.05.31-GEN. February 2012, with standard winding >55 - - - - - - - - - - - - kW. 331 IE1 motor not for sale for use in EU 421 VIK design (Verband der Industriellen Energie- und Kraftwirtschaft e.V.). - 540 China energy label - - 543 Australian MEPS - - - 546 SABS rating plate - 548 Certificate of conformity according TR-CU 004/2011 for customs union RU, KZ, BY, AM, KG. 822 WIMES 3.03i6 Compliant Design for DOL operation - - - - - - - 823 WIMES 3.03i6 Compliant Design for VSD operation Stator winding temperature sensors = Included as standard = Available as option - = Not applicable ABB Motors and Generators | 9AKK105944 EN 02-2020 59 Frame size Code/Variants 71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450 120 KTY 84-130 (1 per phase) in stator winding. - - - - - - 121 Bimetal detectors, break type (NCC), (3 in series), 130 ºC, in stator winding 122 Bimetal detectors, break type (NCC), (3 in series), 150 ºC, in stator winding 123 Bimetal detectors, break type (NCC), (3 in series), 170 ºC, in stator winding 124 Bimetal detectors, break type (NCC), (3 in series), 140 ºC, in stator winding - - - - - - 125 Bimetal detectors, break type (NCC), (2x3 in series), 150 ºC, in stator - - - - - - winding 127 Bimetal detectors, break type (NCC), (3 in series, 130 ºC & 3 in series, 150 ºC), in stator winding 435 PTC - thermistors (3 in series), 130 ºC, in stator winding 437 PTC - thermistors (3 in series), 170 ºC, in stator winding 438 PTC - thermistors (3 in series), 190 ºC, in stator winding - - - - - - - - - - - 439 PTC - thermistors (2x3 in series), 150 ºC, in stator winding 441 PTC - thermistors (3 in series, 130 ºC & 3 in series, 150 ºC), in stator winding 442 PTC - thermistors (3 in series, 150 ºC & 3 in series, 170 ºC), in stator winding 445 Pt100 2-wire in stator winding, 1 per phase 446 Pt100 2-wire in stator winding, 2 per phase - - - - - - 502 Pt100 3-wire in stator winding, 1 per phase - - - - - - 503 Pt100 3-wire in stator winding, 2 per phase - - - - - - 511 PTC thermistors (2 x 3 in series), 130 ºC, in stator winding - - - - - - 515 Pt100 3-wire in stator winding, 3 per phase - - - - - - - - - - - Terminal box 015 Motor supplied in D connection. - - - - - 017 Motor supplied in Y connection. - - - - - 019 Larger than standard terminal box. - - - - - - 020 Detached terminal box. - - - - - - - - - - - 021 Terminal box LHS (seen from D-end). - 022 Cable entry LHS (seen from D-end). 157 Terminal box degree of protection IP65. - - - - - - - 180 Terminal box RHS (seen from D-end). - 230 Standard metal cable gland. - - 277 Cable sealing end unit, size small for C-opening - - - - - - - - - - -- - - - 278 Cable sealing end unit, size medium for D-opening - - - - - - - - - - - - 279 Cable sealing end unit, size large for D-opening - - - - - - - - - - - - 292 Adapter C-C - - - - - - - - - - -- - - - 293 Adapter D-D - - - - - - - - - - - - - - 294 Adapter E-D - - - - - - - - - - - - 295 Adapter E-2D - - - - - - - - - - - - 296 Adapter E-3D - - - - - - - - - - - - - - 351 Terminal block turned according to cable entry - - - - - - - - - - - - 375 Standard plastic cable gland - - - - - 376 Two standard plastic cable glands - - - - - 380 Separate terminal box for temperature detectors, std. material - - - - - - 400 4 x 90 degr turnable terminal box. - - 413 Extended cable connection, no terminal box. - - - - - - 418 Separate terminal box for auxiliaries, standard material. 444 Adapter E-2E -------------- - 447 Top mounted separate terminal box for monitoring equipment. - - - - - - - - - - - 466 Terminal box at N-end. - - - - - - 467 Lower than standard terminal box and rubber extended cable. Cable - - - - - - - - - - length 2 m 468 Cable entry from D-end. - - 469 Cable entry from N-end. - 526 Existing cable entries plugged - - 553 Terminal box degree of protection IP66. - 554 Cast iron flange for cable glands drilled and tapped according to order. - - - - - - 557 Nickel plated cable glands mounted according to order. - = Included as standard = Available as option - = Not applicable 60 9AKK105944 EN 02-2020 | ABB Motors and Generators Frame size Code/Variants 71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450 565 Adapter for terminal box on the side (RHS) - - - - - - - - - - 566 Adapter for terminal box on the side (LHS) - - - - - - - - - - 567 Separate terminal box material: cast Iron - - - - - - 568 Separate terminal box for heating elements, std. material - - - - - - 569 Separate terminal box for brakes - - - - - - 624 Prepared for inch cable glands according to BSPP standard. 727 Stainless steel flange for cable glands drilled and tapped according to order. - - - - - - 730 Prepared for NPT cable glands. 731 Two standard metal cable glands. 740 Prepared for PG cable glands. - - - - - - - - - - - 742 Protective cover for accessory terminal block in main terminal box. - - - - - - - - - - - 743 Non-drilled cast iron flange for cable glands - - - - - - 744 Stainless steel non-drilled flange for cable glands. - - - - - - 745 Painted steel flange equipped with nickel plated brass cable glands - - - - - - 746 Stainless steel cable flange equipped with standard nickel plated brass cable glands - - - - - - Testing 140 Test confirmation. - - - - - - - - - - - 145 Type test report from a catalogue motor, 400V 50Hz. 146 Type test with report for one motor from specific delivery batch. 148 Routine test report. 149 Test according to separate test specification. - - - - - - - - - - - 150 Customer witnessed testing. Specify test procedure with other codes. 222 Torque/speed test, type test and multi-point load test with report for one motor from specific delivery batch. 560 Shaft voltage test. 561 Overspeed test,for one motor from specific delivery batch 562 Overvoltage test. 760 Vibration level test 761 Vibration spectrum test for one motor from specific delivery batch. - - - - - - 762 Noise level test for one motor from specific delivery batch. 763 Noise spectrum test for one motor from specific delivery batch. - - - - - - 764 Test for one motor from specific delivery batch with ABB frequency - - - - - - converter available at ABB test field. ABB standard test procedure. Variable speed drives 429 Separate motor cooling (fan top, N-end) and 1024 pulse tacho (Leine - - - - - - - - - - - & Linde 861) mounted. 470 Prepared for hollow shaft pulse tacho (L&L equivalent). - - - - - - 472 1024 pulse tacho (L&L 861007455-1024). - - - - 473 2048 pulse tacho (L&L 861007455-2048). - - - - 474 Separate motor cooling (axial fan, N-end) and prepared for hollow shaft tacho (L&L equivalent) - - - - - - 476 Separate motor cooling (axial fan, N-end) and 1024 pulse tacho (L&L - - - - - - 861007455-1024) 477 Separate motor cooling (axial fan, N-end) and 2048 pulse tacho (L&L - - - - - - 861007455-2048) 478 Separate motor cooling (fan on top, N-end) and prepared for hollow - - - - - - - - - - - shaft tacho (L&L equivalent) 479 Mounting of other type of pulse tacho with shaft extension, tacho not included. - - - - - - - - 486 Separate motor cooling (fan top, N-end) and prepared for DC-tacho. - - - - - - - - - - - 510 Separate motor cooling (fan top, N-end) and 2048 pulse tacho (Leine - - - - - - - - - - - & Linde 861) mounted. 570 Prepared for hollow shaft pulse tacho (L&L 503). - - - - - - - - - - - 572 1024 pulse tacho (L&L 503). - - - - - - - - - - - 573 2048 pulse tacho (L&L 503). - - - - - - - - - - - 582 1024 pulse tacho, GHK912-GBR-1024, BEI IDEACOD - - - - - - - - - - - 583 2048 pulse tacho, GHK912-GBR-2048, BEI IDEACOD - - - - - - - - - - - 588 Shaft grounding device - - - - - - - - 658 Special tacho mounted, price category 1 - - - - - - 659 Special tacho mounted, price category 2 - - - - - - 660 Special tacho mounted, price category 3 - - - - - - 680 2048 pulse tacho, Ex d, tD, L&L 841910001 - - - - - - - - - - - = Included as standard = Available as option - = Not applicable ABB Motors and Generators | 9AKK105944 EN 02-2020 61 Code/Variants 701 Insulated bearing at N-end. 702 Insulated bearings at both ends 704 EMC cable entry. Y/D starting 117 Terminals for Y/D start at both speeds (two speed windings). 118 Terminals for Y/D start at high speed (two speed windings). 119 Terminals for Y/D start at low speed (two speed windings). = Included as standard = Available as option - = Not applicable Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 62 9AKK105944 EN 02-2020 | ABB Motors and Generators Mechanical design Motor frame and drain holes Motor frame 01 As standard, motor sizes 71 - 450 are The motor frame, end shields and main terminal delivered with drain holes and closable plugs. box are made of cast iron. Feet are integrated with the frame, except for sizes 160-250 with side mounted terminal box, which have detachable feet. Motors can be supplied for foot mounting, flange mounting, and combinations of these. Drain holes Motors are provided with drain holes fitted with closable plugs as standard. The plugs are made of plastic material and are delivered in open position. When mounting arrangement differs from foot mounted IM B3, mention variant code 066 when ordering to ensure the drain plug is mounted in the lowest position. open closed open __ 01 ABB Motors and Generators | 9AKK105944 EN 02-2020 63 Lifting lugs The motors are provided as standard with lifting lugs according to the table below. For improved lifting possibilities can variant code 305 be added, please refer to the variant code section for information about availability. Frame size 71, 80 90-132 160-200 225-250 280, 315 355 400 450 Type of lugs No lugs, weight of motors is less than 25kg Detachable eye bolt Integrated in casting / detachable eye bolt Integrated in casting / detachable eye bolt Detachable eye bolt Detachable eye bolt Detachable eye bolt Detachable eye bolt Foot mounted motors - Flange mounted motors - 2 pcs on top of motor diagonally placed, size M8 2 pcs on top of motor diagonally placed, size M8 2 pcs on top of motor diagonally placed, integrated in frame casting Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end. 2 pcs eye bolts size M12 delivered with each motor 2 pcs on top of motor diagonally placed, integrated in frame casting Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end. 2 pcs eye bolts size M16 delivered with each motor 1 pcs close to terminal box on top, size M24 Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end, one location on top close to terminal box. 2 pcs eye bolts size M24 delivered with each motor 1 pcs close to terminal box on top, size M30 Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end, one location on top close to terminal box. 2 pcs eye bolts size M30 delivered with each motor 1 pcs close to terminal box on top, size M36 Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end, one location on top close to terminal box. 2 pcs eye bolts size M36 delivered with each motor Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end, one location on top close to terminal box. 3 pcs eye bolts size M42 delivered with each motor Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end, one location on top close to terminal box. 2 pcs eye bolts size M42 delivered with each motor 64 9AKK105944 EN 02-2020 | ABB Motors and Generators Mechanical design Heating elements Heating elements are installed into windings to keep them free of corrosion in humid conditions. The required power of heating elements is shown in the table. You can order heating elements with variant code 450 or 451. Motor 71 size Power 8 (W) 80 90 8 25 100 112 132 160 180 25 25 25 25 50 Motor 200 225 250 280 315 355 400 450 size Power 50 50 50 60 2x60 2x60 2x60 2x100 (W) ABB Motors and Generators | 9AKK105944 EN 02-2020 65 Mechanical design Bearings Process performance motors are normally fitted with single-row deep-groove ball bearings, as shown in the table below. If the bearing at the D-end is replaced with a roller bearing (NU- or NJ-), higher radial forces can be handled. Roller bearings are suitable for belt-drive applications and can be ordered with variant code 037. When high axial forces are involved, angular-contact ball bearings should be used. When ordering a motor with an angular-contact ball bearing, specify also the method of mounting and the direction and magnitude of axial force. The variant codes for ordering angular-contact ball bearings are 058 and 059. Standard and alternative designs Standard design Motor size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450 1) On request Number of poles 2 - 8 2 - 8 2 - 8 2 - 8 2 - 8 2 - 8 2 - 12 2 - 12 2 - 12 2 - 12 2 - 12 2 4 - 12 2 4 - 12 2 4 - 12 2 4 - 12 2 4 - 12 Deep groove ball bearings D-end 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6206-2Z/C3 6206-2Z/C3 6208-2Z/C3 6309/C3 6310/C3 6312/C3 6313/C3 6315/C3 6316/C3 6316/C3 6316/C3 6319/C3 6316M/C3 6322/C3 6317M/C3 6324/C3 6317M/C3 6326M/C3 N-end 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6205-2Z/C3 6208-2Z/C3 6209/C3 6209/C3 6210/C3 6212/C3 6213/C3 6316/C3 6316/C3 6316/C3 6316/C3 6316M/C3 6316/C3 6317M/C3 6319/C3 6317M/C3 6322/C3 Alternative designs Roller bearings (037) Ang. contact ball bearings (058, 059) D-end NU 203 ECP/C3 NU 204 ECP/C3 NU 205 ECP/C3 NU 206 ECP/C3 NU 206 ECP/C3 NU 208 ECP/C3 NU 309 ECP/C3 NU 310 ECP/C3 NU 312 ECP/C3 NU 313 ECP/C3 NU 315 ECP/C3 1) NU 316 ECP/C3 1) NU 319 ECP/C3 1) NU 322 ECP/C3 1) NU 324 ECP/C3 1) NU 326 ECP/C3 D-end 7203 B 7204 B 7205 B 7206 B 7206 B 7208 B 7309 B 7310 B 7312 B 7313 B 7315 B 7316 B 7316 B 7316 B 7319 B 7316 B 7322 B 7317 B 7324 B 7317 B 7326 B N-end 7202 B 7203 B 7204 B 7205 B 7205 B 7208 B 7209 B 7209 B 7210 B 7212 B 7213 B 7616 B 7316 B 7316 B 7316 B 7316 B 7316 B 7317 B 7319 B 7317 B 7322 B 66 9AKK105944 EN 02-2020 | ABB Motors and Generators 01 Motor sizes 71 - 132. 02 Motor sizes 160 - 250. 03 Motor sizes 280 - 450 Labyrinth seal. 04 V-ring. 05 Radial seal. Axially-locked bearings All motors are equipped as standard with an axially locked bearing at the D-end. Transport locking Motors with roller bearings or an angular-contact ball bearing are fitted with a transport lock before dispatch to prevent damage to bearings during transport. A warning sign is attached to motors larger than 250 when transport locking is used. Locking may also be fitted in other cases if severe transport conditions are expected. Bearing seals These tables present the standard and alternative sizes and types of bearing seals per motor size. Bearing seals Standard design Alternative design NumMotor ber of size poles 71 2 - 12 80 2 - 12 90 2 - 12 100 2 - 12 112 2 - 12 132 2 - 12 160 2 - 12 180 2 - 12 200 2 - 12 225 2 - 12 250 2 - 12 Axial seal D-end Gamma seal Gamma seal Gamma seal Gamma seal Gamma seal VA40 RB45 RB50 RB60 RB65 RB75 N-end Gamma seal Gamma seal Gamma seal Gamma seal Gamma seal VA40 RB45 RB45 RB50 RB60 RB65 Radial seal at D-end (DIN 3760) Variant code 072 17x28x7 20x40x7 25x42x7 30x47x7 30x47x7 40x62x7 45x62x8 50x68x8 60x80x8 65x85x10 75x95x10 __ __ __ 01 02 03 __ __ 04 05 Bearing seals Motor size 280 280 Number of poles 2 4 - 12 4 - 12 315 315 SM, ML 2 4 - 12 4 - 12 315 LK 4 - 12 4 - 12 355 2 355 4 - 12 400 2 400 4 - 12 450 2 450 4 - 12 Table is valid for IE2 motors Axial seal: RB45...75 = Gamma-ring VA16...65 = V-ring, type A VS80...95 = V-ring, type S Standard design D-end Labyrinth seal VS80 N-end, IE2-IE3 motors VS80 VS80 N-end, IE4 motors Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal VS95 VS80 VS80 Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal VS80 Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal VS80 VS80 Labyrinth seal VS95 Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Alternative design D-end Labyrinth seal Radial seal 80x110x10 Labyrinth seal Radial seal 95x125x10 - - N-end Labyrinth seal Labyrinth seal Radial seal 80x110x10 Labyrinth seal Labyrinth seal Radial seal 80x110x10 Labyrinth seal Radial seal 80x110x10 Labyrinth seal Labyrinth seal Labyrinth seal - ABB Motors and Generators | 9AKK105944 EN 02-2020 67 Bearing life and lubrication Bearing life The nominal life L10h of a bearing is defined according to ISO 281 as the number of operating hours achieved or exceeded by 90 % of identical bearings in a large test series under specified conditions. 50 % of bearings achieve at least five times this lifetime. The calculated bearing life L10h for power transmission by means of coupling is for horizontally mounted motors in sizes 280 to 315 200,000 hours. Lubrication On delivery, motors in frame size 160 and above are prelubricated with high-quality grease. Before first start-up, see instructions for relubricaton and recommended grease in the Manual for low voltage motors delivered together with the motor, or see the lubrication plate on the motor. Motors with bearings greased for life Motors in frame sizes 71 - 132 are equipped with bearings greased for life, while this is available as an option for frame sizes 160 - 250. Bearings are lubricated with high-quality, high-temperature grease. Bearing types are stated on the rating plate. The approximate lifetime of bearings in four-pole motors is about 40 000 duty hours. Lifetime is subject to the load conditions of the application run by the motor. Lubrication intervals ABB follows the L1 principle in defining lubrication intervals. This means that 99 % of motors will make the interval time. The lubrication intervals can also be calculated according to the L10 principle, which usually gives twice as long interval times. L10 values are available from ABB at request. Motors with relubrication nipples In frame sizes 280 - 450, the bearing system allows the use of a valve disc to ease lubrication. Motors are lubricated while running. The grease outlet opening has closing valves at both ends. These should be opened before greasing and closed 1 - 2 hours after regreasing. This ensures that the construction is tight and bearings remain dust- and dirt-free. A grease-collection method can be used optionally. The following tables show lubrication intervals according to the L1 principle for various nominal speeds in 25 °C ambient temperature. These values apply to horizontally mounted motors (B3) with 80 °C bearing temperature and high-quality grease containing lithium-complex soap and mineral or PAO-oil. 68 9AKK105944 EN 02-2020 | ABB Motors and Generators Lubrication intervals in duty hours for ball bearings Frame size Amount Amount of of grease grease g/bear- g/N- Output ing end kW Speed 3600 r/min Ball bearings Lubrication intervals in duty hours 160 13 13 18.5 160 13 13 > 18.5 180 15 15 22 180 15 15 > 22 200 20 15 37 200 20 15 > 37 225 23 20 45 250 23 20 > 45 250 30 23 55 250 30 23 > 55 280 35 35 all 280 40 40 315 35 35 all 315 55 40 355 35 35 all 355 70 40 400 40 40 all 400 85 55 450 40 40 all 450 95 70 9000 7500 7000 6000 5500 3000 4000 1500 2500 1000 1900 1900 1900 1500 1500 - Speed 3000 r/min 12 000 10 000 9000 8500 8000 5500 6500 2500 4000 1500 3200 3200 3200 2700 2700 - Speed Output 1800 kW r/min 15 > 15 22 > 22 30 > 30 45 > 45 55 > 55 all all all all all 18 000 15 000 15 500 14 000 14 500 10 000 13 000 5000 9000 3500 7800 5900 4000 3200 2500 Speed 1500 r/min 21 500 18 000 18 500 17 000 17 500 12 000 16 500 6000 11 500 4500 9600 7600 5600 4700 3900 Speed Output 1000 kW r/min Speed Output 500-900 kW r/min 11 > 11 15 > 15 22 > 22 30 > 30 37 > 37 all all all all all 24 000 all 22 500 all 24 000 all 21 000 all 23 000 all 16 000 all 22 000 all 8000 all 15 000 all 6000 all - 13 900 all - 11 800 all - 9600 all - - 8600 all - 7700 all 24 000 24 000 24 000 24 000 24 000 20 000 24 000 10 000 18 000 7000 15 000 12 900 10 700 9700 8700 Lubrication intervals in duty hours for roller bearings Frame size Amount Amount of of grease grease g/bear- g/N- Output ing end kW Speed 3600 r/min Roller bearings Lubrication intervals in duty hours 160 13 13 18.5 160 13 13 > 18.5 180 15 15 22 180 15 15 > 22 200 20 15 37 200 20 15 > 37 225 23 20 45 225 23 20 > 45 250 30 23 55 250 30 23 > 55 280 35 35 all 280 40 40 315 35 35 all 315 55 40 355 35 35 all 355 70 40 400 40 40 all 400 85 55 450 40 40 all 450 95 70 4500 3500 3500 3000 2750 1500 2000 750 1000 500 900 900 900 - Speed 3000 r/min 6000 5000 4500 4000 4000 2500 3000 1250 2000 750 1600 1600 1600 1300 1300 - Speed Output 1800 kW r/min 15 > 15 22 > 22 30 > 30 45 > 45 55 > 55 all all all all all 9000 7500 7500 7000 7000 5000 6500 2500 4500 1500 4000 2900 2000 1600 1300 Speed 1500 r/min 10 500 9000 9000 8500 8500 6000 8000 3000 5500 2000 5300 3800 2800 2400 2000 Speed Output 1000 kW r/min 11 > 11 15 > 15 22 > 22 30 > 30 37 > 37 all all all all all 12 000 11 000 12 000 10500 11 500 8000 11 000 4000 7500 3000 7000 5900 4800 4300 3800 Speed Output 500-900 kW r/min all 12 000 all 12 000 all 12 000 all 12 000 all 12 000 all 10 000 all 12 000 all 5000 all 9000 all 3500 - all 8500 - all 6500 - all 5400 - all 4800 - all 4400 ABB Motors and Generators | 9AKK105944 EN 02-2020 69 Mechanical design Radial forces Permissible loading on the shaft The following table shows permissible radial forces on the shaft in Newtons, assuming zero axial force, a 25 °C ambient temperature, and normal conditions. The values are given for a calculated bearing life of 20 000 and 40 000 hours per motor size. These calculated values further assume mounting position IM B3 (foot-mounted), with force directed sideways. In some cases, the strength of the shaft affects permissible forces. Permissible loads of simultaneous radial and axial forces can be supplied on request. If the radial force is applied between points X0 and Xmax, the permissible force FR can be calculated with the following formula: X FR = FX0 - E (FX0 - F ) Xmax Where: E: length of the shaft extension in the standard version FR X F Xmax F X0 Permissible radial forces Motor size Poles 71 2 4 6 8 80 2 4 6 8 90 2 4 6 8 100 2 4 6 8 112 2 4 6 8 132 2 4 6 8 Length of shaft extension E (mm) 30 30 30 30 40 40 40 40 50 50 50 50 60 60 60 60 60 60 60 60 80 80 80 80 Basic design with deep groove ball bearings Roller bearings Mounting arrangement IM B3 Mounting arrangement IM B3 20,000 h 40,000 h 20,000 h 40,000 h FX0(N) 540 700 780 860 710 940 1060 1185 820 1035 1185 1300 1130 1425 1635 1820 1170 1475 1690 1860 1840 2320 2660 2925 FXmax(N) 460 605 665 730 600 810 895 1020 690 870 995 1095 925 1165 1335 1520 980 1235 1310 1310 1500 1890 2165 2380 FX0(N) 420 555 620 685 385 725 840 940 650 820 940 1035 900 1135 1295 1445 925 1170 1340 1475 1460 1840 2110 2320 FXmax(N) 360 480 530 580 350 625 710 810 545 690 790 870 735 925 1060 1205 775 980 1120 1235 1190 1500 1715 1890 FX0(N) 1285 1615 1640 1640 1910 2335 2335 2335 2205 2715 3065 3340 2905 3575 4040 4460 3000 3695 4170 4550 4255 5240 5915 6450 FXmax(N) 650 650 650 600 865 865 865 865 1330 1330 1330 1330 1900 1900 1900 1900 1970 1970 1970 1970 3465 4265 3680 3680 FX0(N) 1040 1310 1450 1580 1555 1945 2160 2335 1790 2205 2490 2715 2360 2905 3280 3620 2435 3000 3390 3695 3455 4255 4805 5240 FXmax(N) 650 650 650 600 865 865 865 865 1330 1330 1330 1330 1900 1900 1900 1900 1970 1970 1970 1970 2815 3465 3680 3680 70 9AKK105944 EN 02-2020 | ABB Motors and Generators Permissible radial forces Motor size Poles 160 MLA 2 4 6 8 160 MLB 2 4 6 8 160 MLC 2 4 6 8 160 MLD 2 4 160 MLE 2 180 MLA 2 4 6 8 180 MLB 2 4 6 180 MLC 4 200 MLA 2 4 6 8 200 MLB 2 4 6 200 MLC 2 4 6 200 MLD 2 225 SMA 2 4 6 8 225 SMB 2 4 6 8 225 SMC 2 4 225 SMD 2 4 250 SMA 2 4 6 8 250 SMB 2 4 6 250 SMC 2 4 6 Length of shaft extension E (mm) 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 140 140 140 110 140 140 140 110 140 110 140 140 140 140 140 140 140 140 140 140 140 Ball bearings 20,000 h FX0(N) 3540 4000 4170 4600 3540 4085 4100 4200 3400 3700 3600 4170 3585 3400 3185 4100 4270 4700 4785 4170 4185 4370 3700 5600 6285 6800 6800 5670 5700 6400 5000 5400 5800 4985 6400 7300 7600 8500 6100 7085 7100 8000 5600 6400 5500 5800 7700 8700 9400 9600 7100 7800 8900 6800 7400 8200 FXmax(N) 2740 3100 3200 3585 2740 3300 3355 3270 2600 3000 2900 3370 2900 2755 2570 3385 3485 3800 3900 3400 3400 3570 3055 4685 5200 5700 5700 4700 4700 5370 4185 4500 4885 4170 5400 5900 6200 6900 5185 5700 5700 6485 4700 5200 4640 4700 6285 7000 7600 7800 5800 6300 7200 5500 6000 6600 40,000 h FX0(N) 2955 3325 3440 3855 2955 3370 3400 3455 2855 3070 2870 3370 3000 2755 2640 3455 3525 3855 3870 3470 3440 3525 3010 4700 5240 5700 5600 4700 4700 5300 4185 4425 4740 4170 5355 6155 6370 7100 5155 5885 5840 6600 4685 5300 4600 4725 6500 7300 7800 7900 6000 6470 7355 5670 6055 6670 FXmax(N) 2285 2570 2655 2985 2270 2725 2755 2670 2200 2485 2325 2725 2440 2240 2140 2825 2885 3155 3170 2825 2810 2885 2470 3925 4370 4770 4685 3925 3925 4425 3500 3685 3955 3485 4500 4970 5140 5725 4340 4755 4700 5340 3940 4285 3880 3800 5285 5900 6355 6400 4885 5240 5955 4600 4900 5400 Roller bearings 20,000 h FX0(N) 7100 8000 8600 9300 7085 8300 8600 9000 6800 7800 8000 9000 7100 7600 6785 8125 8600 9400 9800 7900 8500 9000 7900 10900 12500 13600 14100 11000 12000 13200 10400 11600 12500 10400 13300 15400 16400 17900 13000 15100 16000 17300 12600 14500 12420 13500 17100 19800 21600 22700 16700 18900 21200 16300 18100 20300 FXmax(N) 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 5500 5500 5500 5500 5500 5500 5500 5500 9100 9550 9550 9550 9200 9550 9550 8700 9550 9550 8700 10700 10250 10250 10250 10700 10250 10250 10250 10600 10250 10460 10250 10900 13800 13800 13800 10900 13800 13800 10900 13800 13800 40,000 h FX0(N) 6140 6870 7270 7955 6070 7055 7300 7570 5885 6640 6700 7585 6140 6370 5770 7025 7300 7900 8255 6770 7200 7600 6655 9470 10700 11670 12000 9500 10185 11200 8900 9800 10600 8900 11500 13200 14000 15300 11200 12900 13500 14700 10770 12385 10640 11400 14900 17000 18400 19300 14400 16200 18000 14000 15400 17200 FXmax(N) 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 5500 5500 5500 5500 5500 5500 5500 5440 7900 8900 9550 9550 7900 8500 9385 7455 8200 8800 7400 9700 10250 10250 10250 9455 10250 10250 10250 9070 10000 8960 9270 10900 13785 13800 13800 10900 13100 13800 10900 12485 13800 ABB Motors and Generators | 9AKK105944 EN 02-2020 71 Permissible radial forces Motor size Poles 280 SM_ 2 4 6 8 280 ML_ 2 4 6 8 315 SM_ 2 4 6 8 315 ML_ 2 4 6 8 315 LK_ 2 4 6 8 355 SM_ 2 4 6 8 355 ML_ 2 4 6 8 355 LK_ 2 4 6 8 400 L_ 2 4 6 8 400 LK_ 2 4 6 8 450 L_ 2 4 6 8 Length of shaft extension E (mm) 140 140 140 140 140 140 140 140 140 170 170 170 140 170 170 170 140 170 170 170 140 210 210 210 140 210 210 210 140 210 210 210 170 210 210 210 170 210 210 210 170 210 210 210 Ball bearings 20,000 h FX0(N) 7300 9200 10600 11700 7400 9200 10500 11600 7300 11400 13000 14400 7400 11500 13200 14500 7400 11500 13200 14600 7350 15200 17500 19300 7350 15300 17600 19400 7350 15200 17500 19400 7650 15600 17800 19700 7650 15600 17800 19700 7400 17000 19000 21300 FXmax(N) 6000 7800 8900 9200 6200 7900 9000 9500 6000 9400 9600 9600 6400 9700 11100 12200 6550 10000 11400 12600 6450 12600 14000 14000 6550 12900 13600 13600 6650 13000 13000 13000 6850 13550 15450 16000 6850 11500 11500 11500 6700 15200 17000 19000 40,000 h FX0(N) 5800 7300 8400 9200 5800 7300 8300 9200 5800 9000 10300 11400 5850 9100 10400 11500 5800 9100 10450 11550 5750 12000 13800 15250 5750 12000 13900 15300 5650 11850 13700 15200 4400 12150 13850 15350 4400 12150 13850 15350 3500 13000 14000 16500 FXmax(N) 4900 6200 7000 7800 5000 6200 7100 7900 4950 7450 8500 9400 5050 7650 8800 9700 5150 7850 9050 10000 5050 9950 11400 12600 5100 10100 11600 12900 5100 10200 11900 13000 3900 10550 12000 13350 3900 10550 11500 11500 3300 11600 13000 14600 Roller bearings 20,000 h FX0(N) 20400 25100 28300 30900 20600 25000 28300 30800 20300 32500 37000 40300 20600 32700 36900 40200 20800 33100 37300 40800 20600 45500 51400 56000 20800 45900 51500 56000 21000 46000 52000 56500 23900 52500 60000 65700 23900 52500 60000 65700 24000 62000 70000 76000 FXmax(N) 6000 9200 9200 9200 6200 9500 9400 9500 6000 9600 9600 9600 5850 13600 13600 13600 5550 13350 13350 13350 7200 14000 14000 14000 6750 13600 13600 13600 6550 13000 13000 13000 9050 16000 16000 16000 9050 11500 11500 11500 7500 25000 24000 23000 40,000 h FX0(N) 16500 20300 23000 25100 16700 20300 22900 25000 16500 26600 30000 32700 16700 26500 29900 32600 16800 26800 30300 33100 16700 36900 41700 45500 16800 37200 42100 45900 17000 37300 42000 46000 19350 43300 48800 53200 19350 43300 48800 53200 19000 50000 56000 62000 FXmax(N) 6000 9200 9200 9200 6200 9500 9400 9500 6000 9600 9600 9600 5850 13600 13600 13600 5550 13350 13350 13350 7200 14000 14000 14000 6750 13600 13600 13600 6550 13000 13000 13000 9050 16000 16000 16000 9050 11500 11500 11500 7500 25000 24000 23000 72 9AKK105944 EN 02-2020 | ABB Motors and Generators Mechanical design Axial forces 01 Mounting arrangement IM B3. 02 Mounting arrangement IM V1. The following tables present permissible axial forces on the shaft in Newtons, assuming zero radial force, a 25 °C ambient temperature, and normal conditions. The values are given for a calculated bearing life of 20,000 and 40,000 hours per motor size. At 60 Hz, the values must be reduced by 10 percent, and for two-speed motors, the higher speed determines permissible axial force. Permissible loads of simultaneous radial and axial forces can be supplied on request. For axial force FAD, it is assumed that the D-bearing is locked with a locking ring. FAZ FAD FAD FAZ __ __ 01 02 Permissible axial forces Motor size Poles 71 2 4 6 8 80 2 4 6 8 90 2 4 6 8 100 2 4 6 8 Length of shaft extension E (mm) 30 30 30 30 40 40 40 40 50 50 50 50 60 60 60 60 Mounting arrangement IM B3 Deep groove ball bearings 20,000 h 40,000 h FAD(N) 615 760 870 960 880 1075 1215 1330 780 985 1140 1265 925 1480 1690 1865 FAZ(N) 285 430 540 630 300 495 635 750 500 705 860 985 570 860 1070 1245 FAD(N) 505 615 695 765 735 880 985 1070 620 775 890 985 735 1190 1350 1480 FAZ(N) 175 285 365 435 155 300 405 490 340 495 610 705 350 570 730 860 Mounting arrangement IM V1 Deep groove ball bearings 20,000 h 40,000 h FAD(N) 630 790 890 985 915 1130 1270 1400 840 1070 1225 1355 1285 1600 1815 1995 FAZ(N) 275 410 525 615 280 455 600 705 455 650 800 925 510 780 995 1160 FAD(N) 520 645 720 785 770 935 1040 1140 680 860 975 1075 1060 1305 1470 1610 FAZ(N) 165 265 355 415 135 260 370 450 300 440 555 645 290 490 650 775 ABB Motors and Generators | 9AKK105944 EN 02-2020 73 Permissible axial forces Motor size Poles 112 2 4 6 8 132 2 4 6 8 160 MLA 2 4 6 8 160 MLB 2 4 6 8 160 MLC 2 4 6 8 160 MLD 2 4 160 MLE 2 180 MLA 2 4 6 8 180 MLB 2 4 6 180 MLC 4 200 MLA 2 4 6 8 200 MLB 2 4 6 200 MLC 2 4 6 200 MLD 2 Length of shaft extension E (mm) 60 60 60 60 80 80 80 80 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 Mounting arrangement IM B3 Deep groove ball bearings 20,000 h 40,000 h FAD(N) 1155 1445 1655 1830 1765 2210 2535 2800 2850 3450 3690 4155 2850 3435 3600 3750 2775 3150 3135 3675 2865 2900 2500 3300 3600 4140 4220 3340 3580 3800 3220 4460 5000 5000 5000 4440 4720 5000 3940 4480 4980 3940 FAZ(N) 595 885 1095 1270 965 1410 1735 2000 2850 3450 3690 4155 2850 3435 3600 3750 2775 3150 3135 3675 2865 2900 2500 3300 3600 4140 4220 3340 3580 3800 3220 4460 5260 5480 5880 4440 4720 5480 3940 4480 4980 3940 FAD(N) 935 1155 1315 1445 1420 1755 2000 2205 2325 2775 2970 3315 2325 2760 2880 2970 2280 2535 2490 2910 2330 2320 2025 2700 2920 3320 3360 2725 2900 3040 2560 3640 4260 4720 4700 3620 3840 4420 3180 3620 3980 3200 FAZ(N) 375 595 755 885 620 955 1200 1405 2325 2775 2970 3315 2325 2760 2880 2970 2280 2535 2490 2910 2330 2320 2025 2700 2920 3320 3360 2725 2900 3040 2560 3640 4260 4720 4700 3620 3840 4420 3180 3620 3980 3200 Mounting arrangement IM V1 Deep groove ball bearings 20,000 h 40,000 h FAD(N) 1290 1595 1810 1985 1925 2420 2770 3055 3100 3820 4100 4440 3120 3880 4120 4140 3080 3620 3680 4240 3220 3420 2900 3660 4160 4800 4960 3760 4220 4500 3880 5000 5000 5000 5000 5000 5000 5000 4600 5000 5000 4660 FAZ(N) 505 785 995 1170 855 1270 1580 1835 2578 3150 3410 3845 2570 3085 3240 3450 2500 2770 2700 3260 2540 2470 2150 2940 3150 3675 3740 2960 3095 3285 2660 3965 4680 5265 5195 3905 4060 4800 3385 3775 4165 3370 FAD(N) 1070 1300 1465 1600 1580 1965 2235 2455 2570 3120 3325 3640 2580 3180 3360 3340 2560 2985 3005 3445 2665 2820 2420 3060 3460 3940 4040 3125 3500 3700 3220 4200 5000 5000 5000 4220 4700 5000 3880 4520 5000 3925 FAZ(N) 280 495 650 780 510 815 1045 1235 2048 2450 2635 3045 2030 2385 2480 2650 1980 2135 2025 2465 1985 1870 1670 2340 2450 2815 2820 2320 2375 2485 2000 3125 3640 4065 3955 3085 3120 3660 2665 2875 3105 2635 74 9AKK105944 EN 02-2020 | ABB Motors and Generators Permissible axial forces Motor size Poles 225 SMA 2 4 6 8 225 SMB 2 4 6 8 225 SMC 2 4 225 SMD 2 4 250 SMA 2 4 6 8 250 SMB 2 4 6 250 SMC 2 4 6 280 SM_ 2 4 6 8 280 ML_ 2 4 6 8 315 SM_ 2 4 6 8 315 ML_ 2 4 6 8 315 LK_ 2 4 6 8 Length of shaft extension E (mm) 110 140 140 140 110 140 140 140 110 140 110 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 170 170 170 140 170 170 170 140 170 170 170 Mounting arrangement IM B3 Deep groove ball bearings 20,000 h 40,000 h FAD(N) 4980 5000 5000 5000 4860 5000 5000 5000 4380 5000 4320 4800 6000 6000 6000 6000 5620 6000 6000 5260 5960 6000 6200 8000 7250 10300 6100 7800 8950 10000 6180 9400 10900 12000 6050 9250 10650 11500 6000 9100 10500 11750 FAZ(N) 4980 6080 6520 7420 4860 5880 6020 6940 4380 5240 4320 4800 6080 7140 7880 8200 5620 6320 7480 5260 5960 6860 4250 6000 9250 8300 4100 5800 6950 8000 4200 7400 8900 10000 4050 7250 8650 9900 3950 7150 8500 9750 FAD(N) 4060 4920 5000 5000 3960 4780 4840 5000 3540 4260 3480 3820 4920 5820 6000 6000 4540 5100 6000 4220 4760 5520 4900 6250 7150 7950 4800 6000 6900 7700 4850 7250 8350 9200 4750 7100 8100 8900 4650 7000 7950 8900 FAZ(N) 4060 4920 5260 5960 3960 4780 4840 5560 3540 4260 3480 3820 4920 5820 6380 6600 4540 5100 6040 4220 4760 5520 2900 4250 5150 5950 2800 4000 4900 5700 2850 5250 6350 7000 2750 5100 6100 6800 2650 5000 5950 6900 Mounting arrangement IM V1 Deep groove ball bearings 20,000 h 40,000 h FAD(N) 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 7550 9600 11150 12200 8150 10450 12350 13450 7950 11750 13600 15350 8650 12500 14900 15400 9100 13100 15700 16900 FAZ(N) 4375 5445 5735 6535 4245 5175 5155 6055 3670 4445 3590 3895 5345 6300 6950 7125 4830 5325 6370 4395 4900 5575 3150 4550 5500 7000 2750 4050 4750 5800 2600 5500 6300 7900 2300 5050 5800 6300 1350 3850 4100 6300 FAD(N) 4780 5000 5000 5000 4780 5000 5000 5000 4440 5000 4400 5000 5840 6000 6000 6000 5640 6000 6000 5400 6000 6000 6200 7800 9000 9850 6800 8650 10250 11050 6600 9550 11050 12450 7300 10300 12350 13600 7750 10900 13100 14100 FAZ(N) 3455 4225 4395 5095 3345 3995 3915 4635 2900 3425 2790 2935 4225 4920 5350 5385 3810 4085 4830 3415 3700 4135 1800 2750 3350 4700 1400 2250 2600 3450 1300 3300 3750 5000 1) 2900 3250 3400 1) 1700 1550 3450 ABB Motors and Generators | 9AKK105944 EN 02-2020 75 Permissible axial forces Motor size Poles 355 SM_ 2 4 6 8 355 ML_ 2 4 6 8 355 LK_ 2 4 6 8 400 L, LK_ 2 4 6 8 450 L_ 2 4 6 8 1) On request. Length of shaft extension E (mm) 140 210 210 210 140 210 210 210 140 210 210 210 170 210 210 210 170 210 210 210 Mounting arrangement IM B3 Deep groove ball bearings 20,000 h 40,000 h FAD(N) 3050 8600 10550 12200 2900 8360 10100 12000 2650 8200 9900 11450 2150 7100 8850 10450 1800 7600 9000 10800 FAZ(N) 6850 12400 14350 16000 6700 12150 13900 15800 6450 12000 13700 15250 7150 13100 14850 16450 6800 13500 15000 16800 FAD(N) 1750 5900 7300 8550 1600 5650 6900 7300 1350 5450 6700 7800 1) 4300 5500 6750 1) 4500 5600 7000 FAZ(N) 5550 9700 11100 12350 5400 9450 10700 11000 5150 9250 10500 11600 5800 10300 11500 12750 5500 10500 11500 12900 Mounting arrangement IM V1 Deep groove ball bearings 20,000 h 40,000 h FAD(N) 6350 13250 15650 17350 7100 14600 18050 21100 8250 15650 19100 21200 8650 16050 18450 20100 11500 20000 26000 27800 FAZ(N) 4250 8600 9580 12500 3700 7950 8600 11650 2650 6600 7050 8700 2150 6400 6750 8350 1) 4400 3700 5500 FAD(N) 4950 10450 12350 13600 5750 11850 14700 17000 6900 12850 15800 17500 7220 13150 15100 16450 10000 17700 22200 23700 FAZ(N) 2900 5850 6270 8900 2350 5150 5300 7600 1300 3800 3750 5000 1) 3400 3400 4700 1) 1200 1) 1350 76 9AKK105944 EN 02-2020 | ABB Motors and Generators Terminal box Standard terminal box Degree of protection and mounting options The degree of protection for the standard terminal box is IP 55. By default, terminal boxes are mounted on top of the motor at D-end. In motor sizes 71 132, the terminal box is integrated in motor frame. On request, the terminal box can also be mounted on the left or right side regardless of motor size (see Mounting options). Turnability In frame sizes 71 to 132 the terminal box is integrated into the frame and can therefore not be turned. Please use the variant code 400 if there is a need to have 4*90° turnability. The standard terminal boxes for motor sizes 160 to 355 can be turned 4*90°. On frame sizes 400-450 the terminal box can not be turned without turning the terminal board. In these frame sizes you need to specify the cable entry direction when ordering, by using the variant codes 022, 468 or 469. Cable entries The terminal box is provided with tapped holes for cable glands. No cable glands are included as standard, the entry holes are closed with blanking plugs made of plastic. Very large motors have an angle adapter between the terminal box and the cable gland. Please refer to the table on the next page for further information about the amount and size of threaded holes, plugs and cable sealing units provided as standard. Different types of cable glands are available as option. Please refer to the terminal box alternatives section for more details. Cable type and terminations If no cable type is specified in the order, it will be a PVC-insulated non-armored cable, and its termination parts are determined as shown in the following table. Terminations are suitable for copper and aluminum cables. Cables are connected to terminals by cable lugs, which are not included in the delivery. Ordering To ensure the delivery of desired terminations for the motor, state the cable type, quantity, size, and outer diameter when ordering. Non-standard designs of terminal boxes, such as non-standard size or higher degree of protection, are available as options. See section Variant codes for all options available. ABB Motors and Generators | 9AKK105944 EN 02-2020 77 Standard delivery Standard delivery if no other information is provided. For other network voltages than voltage code D (see description on page 18) and/or side-mounted motors, please contact your ABB sales office. Motor size Pole number Size of gland plate open- Terminal box ing on termi- 45° angle type nal box adapter IE2, IE3, IE4 motors 71 2-8 80 2-8 90 2-8 100-132 2-8 160-180 2-8 200-250 2-8 280 2-8 315SM_, ML_ 2-8 315LKA, LKB 2-4 315LKC 2-4 315LK_ 6-8 355SMA - SMC 2-4 355SMA, SMB 6-8 355SMC 6 355SMC 8 355MLA 2-4 355MLB, LK_ 2-4 355ML_, LK_ 6-8 400 2-6 400LA, LB 8 400LC 8 450 LA 2 450 LA 4 450 LB, LC 2-4 450 LA 6 450 LB, LC 6 450 8 integr. - integr. - integr. - integr. - 63 B 160 C 210 C 370 D 370 D 750 E 370 D 750 E 370 D 750 E 370 D 750 E 750 E 750 E 750 E 750 E 750 E 1200 E 1200 E 1200 E 750 E 1200 E 750 E E-2D E-2D E-2D E-2D E-2D E-2D E-2D E-2D E-2D E-2D Amount and size of threaded Max. con- plugged nectable core holes, or cross-sec- Number and cable sealing tion mm2/ size of termi- end unit phase nal bolts 2xM16x1.5 2xM25x1.5 2xM25x1.5 2x M32x1.5 2xM40x1.5 2xM63x1.5 2xM63x1.5 2xM63x1.5 2xM63x1.5 2xM75x1.5 2xM63x1.5 2xM75x1.5 2xM63x1.5 2xM75x1.5 2xM63x1.5 2xM75x1.5 4xM75x1.5 2xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 1x2.5 1x4 1x6 1x10 1x35 1x70 2x150 2x240 2x240 4x240 2x240 4x240 2x240 4x240 2x240 4x240 4x240 4x240 4x240 4x240 4x240 6x240 6x240 6x240 4x240 6x240 4x240 6 x M4 6 x M4 6 x M5 6 x M5 6 x M6 6 x M10 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 Auxiliary cable entries 160 - 450 2-8 2x M20x1.5 Motor size 71-112 132 160-250 280-400 450 Earthing on frame M4 M5 clamp M10 M10 Earthing in main terminal box M4 M5 M6 2xM10 4xM12 78 9AKK105944 EN 02-2020 | ABB Motors and Generators Terminal box Terminal box dimensions 01 Terminal box type 63 and 160. For motor sizes 71 to 132 the terminal box is integrated in motor frame and the dimensions for H 1 terminal boxes can be found in the motor dimen- 02 Terminal box types 210 and 370. sion drawings in ABB Library. A1 03 Terminal box type 750 + adapter. To match the correct terminal box with motor 04 Terminal box type 1200 + adapter. sizes 160 - 450, find the motor type and correspondent terminal box type on the previous page. The B 1 box types and heir dimensions are presented on this page. __ B1 H1 04 B 1 H 1 B 1 H 1 __ 01 A1 __ 02 A1 __ 03 A 1 Terminal box types acc. to current capacity A1 B1 63 247 247 160 300 310 210 416 306 370 451 347 750 with E-D adapter 686 413 750 without E-D adapter 523 413 1200 with E-2D adapter 1000 578 1200 without E-2D adapter 697 578 1200 with E-2E adapter 1195 578 1200 with E-3D adapter 1250 578 Gland plate H1 opening 109 B 154 C 177 C 200 D 219 D 219 E 285 2xD 285 E 285 2xE 285 3xD Dimensions for terminal box inlets Corresponds to motor sizes 160 and above d e c f g Flange opening B C *) C **) D E c e f g d mm mm mm mm thread type 31 120 30 120 M6 71 194 62 193 M6 67 193 62 193 M8 100 300 80 292 M10 115 370 100 360 M12 Note! The C flange is different depending on frame size *) for frame sizes 200-225 **) for frame size 280 ABB Motors and Generators | 9AKK105944 EN 02-2020 79 Terminal box Cable glands The motors are delivered as standard with plugged cable entries or cable sealing units as described in the previous section. There is available a broad selection of different type of cable glands, which are suitable for different types of cable and outer diameter ranges. Cable gland(s) EMC Cable Cable nickel plated gland(s) gland(s) Size of thread- brass, variant nickelplated plastic, vari- ed opening for code 230 or brass, variant antcode 375 cable gland 731 code 704 or 376 Metric (std) M16 x 1.5 M20 x 1.5 M25 x 1.5 M32 x 1.5 M40 x 1.5 M50 x 1.5 M63 x 1.5 *) M75 x 1.5 Cable outer diameter, mm 4-12 4-12 10-18 14-24 22-32 26-35 35-45 46-62 Cable outer diameter, mm Cable outer diameter, mm 4-8 4-12 10-18 14-24 4-12 4-12 10-18 14-24 22-32 26-35 35-45 46-62 22-32 26-35 35-45 not available Gland plates with threaded openings for cable glands of nonstandard size If the standard size of threaded openings for cable glands is not suitable then nonstandard size openings are also available, either by fitting the reducers to make the openings smaller or by increasing the amount or size of holes. The maximum possible size and amount for each gland plate size is listed below. Threaded openings of non-standard size can be ordered by using variant codes 554 and 727. Gland plate size B C D E Maximum amount and size of threaded holes 2 x M40 2 x M63 2 x M90 or 3 x M75 2 x M90 or 4 x M75 Threaded openings for cable glands with NPT thread (variant code 730) The standard delivery for the motors are provided with openings for cable glands with metric threads as listed in the section describing the standard terminal box. If NPT threads will be needed, the variant code 730 is to be ordered. If nothing else is stated on the order, the sizes in tables below will be delivered. Motor frame size 80-112 132 160-180 200-250 280 315-450 Main cable entries NPT plug 1 x ¾" - 2 x ¾" 1 x ¾" 2 x 1 ¼" 1 x 1 ¼" 2 x 1 ½" 1 x 1 ½" 2 x 2" 1 x 2" 2 x 3" 1 x 3" Motor frame size 80-112 132 160-450 Cable entries for auxiliaries 2 x ¾" 1 x ¾" 2 x ¾" NPT plug 2 x ¾" 1 x ¾" 2 x ¾" 80 9AKK105944 EN 02-2020 | ABB Motors and Generators Terminal box Terminal boxes and boards 01 Integrated terminal box for motor sizes 71 - 132. Tapped holes for cable entries. 02 Terminal board for motor sizes 71 - 80. 03 Terminal board for motor sizes 90 - 112, IE2, and 90 - 100, IE3. 04 Terminal board for motor sizes 132, IE2, and motor sizes 112 - 132, IE3. 05 Terminal box for motor sizes 160 - 250. Connection flanges with tapped cable entries. 06 Terminal board for motor sizes 160 - 250. The pictures below show standard terminal boxes and the corresponding terminal boards for various motor sizes. Motor sizes 71 - 132 __ 01 Motor sizes 160 - 250 __ 05 __ __ 02 06 __ 03 __ 04 ABB Motors and Generators | 9AKK105944 EN 02-2020 81 07 Terminal box for motor sizes 280 - 315, except LKC. Connection flange with tapped cable entries. 08 Terminal board for motor sizes 280 - 315, except LKC. 09 Terminal box for motor sizes 315-355, except for 355MLB, LK_2-4 where picture 11 applies. Connection flange with tapped cable entries. 10 Terminal board for motor sizes 355-400 and 315 LKC. 11 Terminal box for motor sizes 450, with adapter and cable sealing end unit. 12 Terminal board for motor sizes 450. Motor sizes 280 - 315 __ 07 __ 08 __ 09 __ 10 Motor size 450 __ 11 __ 12 82 9AKK105944 EN 02-2020 | ABB Motors and Generators Terminal box Terminal box alternatives 01 Main terminal box. 02 Adapters, Flange with glands; cable sealing end units. __ 01 Optional adapters There is a broad selection of cable termination accessories available to allow termination of one or several cables. The most common ones are explained below. How to order? Check first that the teminal box itself allows mounting of the desired cable and cores (refer to motor type and terminal box type cross reference on previous page) If very large cables are used it might be necessary to use a larger terminal box than standard. Select the right cable gland(s) or cable sealing end unit(s) that match outer diamater of the cable(s) Select appropriate adapter or flange Note that turning the terminal box to a nonstandard position might limit the use of some adapters. __ 02 Main terminal box and maximum single core cross-section You can select one size larger than standard terminal box if a larger single cross-section is needed. The standard sizes of the main terminal box are listed in the following table. The terminal box is named according to its current-carrying capacity, from 120 to 1200. Check also the capacity of the cable entry to make sure that the cables fit. A larger terminal box can be ordered with variant code 019. Standard terminal box 120 210 370 750 1200 Large terminal box 210 370 750 1200 - Size of opening, large box B C D E - Max single cross-section mm2 /phase 1 x 70 2 x 240 2 x 300 4 x 500 - Ordering example Motor Cables 200 kW, 4 pole, 400 V 50 Hz 2 pieces, outer diameter 58 mm, single core cross section 185 mm2, clamping device needed, cables coming from below Needed one terminal box for anticondensation heaters and another for temperature detectors, material must be cast iron. Motor M3BP 315 MLA 4-pole, B3 Adapter D-D - variant code 293 Cable sealing end unit Variant code 278 Clamping Variant code 231 Auxiliaries Variant codes 380, 567, 568 ABB Motors and Generators | 9AKK105944 EN 02-2020 83 Optional adapters To allow easy termination of cables entering the terminal box from above or below, an angle adapter is recommended. These are available for motor sizes 280 and above and can also be used to allow the mounting of several cable sealing end units or gland plates. For exact suitability on a certain motor size, refer to the `terminal box opening' column in section Standard terminal box. Adapter Variant code 292 Suited for motor sizes 280 Opening to terminal box Flange or opening for end unit Material Notes C C Steel 293 315, 355 D D Steel 294 315 LKC IE2, 355 SM_ 2-4 poles, 400 - 450 E 295 315 LKC IE2, 355 SM_ 2-4 poles, 400 - 450 E 296 315 LKC IE2, 355 SM_ 2-4 poles, 400 - 450 E 444 315 LKC IE2, 355 SM_ 2-4 poles, 400 - 450 E D 2 x D 3 x D 2 x E Cast iron Steel Steel Included as standard Only possible on delivery for frame type 1200 terminal sizes 400-450 and box. 355MLB, LK_ 2-4. Steel Only possible on type 1200 terminal box. Cable sealing end units As an alternative to flanges and cable glands, cable sealing end units can be used. These allow more space for spreading the cores for easy termination. Cable sealing end units have rubber-sealed entries for one of two main cables. In addition, there are two plugged M20 holes for auxiliary cables. End unit Small Medium Large Variant code Suited for motor sizes Opening to terminal box Cable outer diameter Cable entry for auxiliary cable Additional optional variants 277 280 C 1 - 2 cables, 48 - 60 mm 2 x M20 plugged holes EMC cable gland (704); Standard gland with clamping device (231) 278 315, 355, except 315 LKC IE2, 355 SM_ 2-4 poles D 1 - 2 cables, 48 - 60 mm 2 x M20 plugged holes EMC cable gland (704); Standard gland with clamping device (231) 279 315, 355, except 315 LKC IE2, 355 SM_ 2-4 poles D 1 - 2 cables, 60 - 80 mm 2 x M20 plugged holes EMC cable gland (704); Standard gland with clamping device (231) 84 9AKK105944 EN 02-2020 | ABB Motors and Generators Auxiliary terminal box You can equip motors from frame size 160 upward with one or several auxiliary terminal boxes for connection of auxiliaries like heaters or temperature detectors. The standard auxiliary terminal box material for motor sizes 280 - 450 is aluminum and for 160 - 250 cast iron. For 280 - 450, cast iron as box material is also available as an option. Connection terminals are of spring-loaded type for quick and easy connection. These are suitable for up to 2.5 mm2 wires. Auxiliary terminal boxes for 280 - 450 are equipped with an earthing terminal. The first auxiliary terminal box is located on the right-hand side at D-end as standard. The standard cable entry size is M20 for the aluminum box and M16 for the cast iron box, and the number of entries depends on the terminal box type and the number of selected auxiliaries. Related variant codes 380 418 567 568 569 Separate terminal box for temperature detectors,standard material Separate terminal box for auxiliaries, standard material Separate terminal box material: cast iron Separate terminal box for heating elements, standard material Separate terminal box for brake Small auxiliary aluminum terminal box Large auxiliary aluminum terminal box for motor Auxiliary cast iron terminal box for motor sizes 280 - 450 sizes 280 - 450. Frame size for motor sizes 160 - 250 (variant codes 418, 568, 380, 569) The size of terminal box ordered with these codes (variant code 418): The size of terminal box ordered with depends on the number of accessories ordered. 111 x 162 mm, max. 18 strips. No earth- these codes depends on the number 80 x 250 mm, max 30 strips. Earthing size M4 ing. of accessories ordered. 80 x 125 mm, max 12 strips. Earthing size M4 Frame size for motor sizes 280 - 450 (variant code 567): 208 x 180 mm, max 30 strips. Earthing size M6 ABB Motors and Generators | 9AKK105944 EN 02-2020 85 Dimension drawings Process performance IE2 cast iron motors L HD EC B B' Foot-mounted motor IM 1001, IM B3 H K A DS PN LS Flange-mounted motor IM 3001, IM B5 DS D F GA M S 45° Sizes 80 to 200 S M LS 45° Sizes 225 to 450 Protective roof, variant code 005 IM1001, IMB3 and IM3001, IMB5 IM1001, IMB3 IM B5 (IM3001) D Motor size 2 71 14 80 19 90SL_ 24 90L_ 24 100L_ 28 100ML_ 28 100LK_ 28 112 28 132 38 160 1) 42 160 2) 42 180 48 200 55 225 55 250 60 280SM_ 75 280ML_ 65 315 SA 65 315 SM_ 65 315 ML_ 65 315 LK_ 65 355 SM_ 70 355 ML_ 70 355 LK_ 70 400 L_ 80 400 LK_ 80 450 80 GA 4-8 2 F 4-8 2 14 16 16 5 19 21.5 21.5 6 24 27 27 8 24 27 27 8 28 31 31 8 28 31 31 8 28 31 31 8 28 31 31 8 38 41 41 10 42 45 45 12 42 45 45 12 48 51.5 51.5 14 55 59 59 16 60 59 64 16 65 64 69 18 75 79.5 79.5 20 75 69 79.5 18 80 69 85 18 80 69 85 18 90 69 95 18 90 69 95 18 100 74.5 106 20 100 74.5 106 20 100 74.5 106 20 110 85 126 22 100 85 106 22 120 85 127 22 E L max A B B1 C HD K MN P S 4-8 2 4-8 2 4-8 max 5 30 30 295 294 112 90 - 45 178 7 130 110 160 10 6 40 40 363 363 125 100 - 50 194 10 165 130 200 12 8 50 50 356 356 140 100 125 56 218 10 165 130 200 12 8 50 50 390 390 140 100 125 56 218 10 165 130 200 12 8 60 60 381 381 160 140 - 63 247 12 215 180 250 15 8 60 60 403 403 160 140 - 63 247 12 215 180 250 15 8 60 60 435 435 160 140 - 63 247 12 215 180 250 15 8 60 60 403 403 190 140 - 70 259 12 215 180 250 15 10 80 80 532 532 216 140 178 89 300 12 265 230 300 15 12 110 110 584 584 254 210 254 108 421 14.5 300 250 350 19 12 110 110 681 681 254 210 254 108 421 14.5 300 250 350 19 14 110 110 726 726 279 241 279 121 461 14.5 300 250 350 19 16 110 110 821 821 318 267 305 133 528 18.5 350 300 400 19 18 110 140 849 879 356 286 311 149 573 18.5 400 350 450 19 18 140 140 884 884 406 311 349 168 626 24 500 450 550 19 20 140 140 1053 1054 457 368 419 190 733 24 500 450 550 18.5 20 140 140 1189 1189 457 368 419 190 785 24 500 450 550 18.5 22 140 170 1088 1118 508 406 216 845 28 600 550 660 23 22 140 170 1190 1220 508 406 457 216 845 28 600 550 660 23 25 140 170 1285 1315 508 457 508 216 852 30 600 550 660 23 25 140 170 1491 1521 508 457 508 216 880 30 600 550 660 23 28 140 210 1409 1479 610 500 560 254 958 35 740 680 800 23 28 140 210 1514 1584 610 560 630 254 958 35 740 680 800 23 28 140 210 1764 1834 610 710 900 254 958 35 740 680 800 23 28 170 210 1851 1891 710 900 1000 224 1045 35 940 880 1000 28 28 170 210 1851 1891 686 710 800 280 1045 35 740 680 800 24 32 170 210 2147 2187 800 1000 1120 250 1293 42 1080 1000 1150 28 1) MLA, MLB 2, MLB 8, MLC 2 2) MLB 4-6, M3C 4-8, MLD, ML3 86 9AKK105944 EN 02-2020 | ABB Motors and Generators IMB14 (IM3601) Motor size M N P S T 71 85 70 105 6 2.5 80 100 80 120 6 3 90 115 95 140 8 3 100 130 110 160 8 3.5 112 130 110 160 8 3.5 132 165 130 200 10 3.5 The table gives the main dimension in mm. For detailed drawings please see our web pages www.abb.com/motors&generators. ABB Motors and Generators | 9AKK105944 EN 02-2020 87 Dimension drawings Process performance IE3 cast iron motors L HD EC B B' Foot-mounted motor IM 1001, IM B3 H K A DS PN LS Flange-mounted motor IM 3001, IM B5 DS D F GA M S 45° Sizes 80 to 200 S M LS 45° Sizes 225 to 450 Protective roof, variant code 005 IM1001, IMB3 and IM3001, IMB5 IM1001, IMB3 IM B5 (IM3001) D Motor size 2 71 14 80 19 90SL_ 24 90L_ 24 100L_ 28 100ML_ 28 100LK_ 28 112 28 132 38 160 1) 42 160 2) 42 180 48 200 55 225 55 250 60 280SM_ 65 280ML_ 65 315 SM_ 65 315 ML_ 65 315 LK_ 65 355 SM_ 70 355 ML_ 70 355 LK_ 70 400 L_ 80 400 LK_ 80 450 80 GA 4-8 2 F 4-8 2 14 16 16 5 19 21.5 21.5 6 24 27 27 8 24 27 27 8 28 31 31 8 28 31 31 8 28 31 31 8 28 31 31 8 38 41 41 10 42 45 45 12 42 45 45 12 48 51.5 51.5 14 55 59 59 16 60 59 64 16 65 64 69 18 75 69 79.5 18 75 69 79.5 18 80 69 85 18 90 69 95 18 90 69 95 18 100 74.5 106 20 100 74.5 106 20 100 74.5 106 20 110 85 126 22 100 85 106 22 120 85 127 22 E L max A B B1 C HD K MN P S 4-8 2 4-8 2 4-8 max 5 30 30 295 294 112 90 - 45 178 7 130 110 160 10 6 40 40 363 363 125 100 - 50 194 10 165 130 200 12 8 50 50 356 356 140 100 125 56 218 10 165 130 200 12 8 50 50 390 390 140 100 125 56 218 10 165 130 200 12 8 60 60 381 381 160 140 - 63 247 12 215 180 250 15 8 60 60 403 403 160 140 - 63 247 12 215 180 250 15 8 60 60 435 435 160 140 - 63 247 12 215 180 250 15 8 60 60 442 442 190 140 - 70 258 12 215 180 250 15 10 80 80 532 532 216 140 178 89 300 12 265 230 300 15 12 110 110 584 584 254 210 254 108 421 14.5 300 250 350 19 12 110 110 681 681 254 210 254 108 421 14.5 300 250 350 19 14 110 110 726 726 279 241 279 121 461 14.5 300 250 350 19 16 110 110 821 821 318 267 305 133 528 18.5 350 300 400 19 18 110 140 849 879 356 286 311 149 573 18.5 400 350 450 19 18 140 140 884 884 406 311 349 168 626 24 500 450 550 19 20 140 140 1088 1088 457 368 419 190 762 24 500 450 550 18 20 140 140 1189 1189 457 368 419 190 785 24 500 450 550 18 22 140 170 1174 1204 508 406 457 216 852 30 600 550 660 23 25 140 170 1285 1315 508 457 508 216 852 30 600 550 660 23 25 140 170 1491 1521 508 457 508 216 880 30 600 550 660 23 28 140 210 1409 1479 610 500 560 254 958 35 740 680 800 23 28 140 210 1514 1584 610 560 630 254 958 35 740 680 800 23 28 140 210 1764 1834 610 710 900 254 958 35 740 680 800 23 28 170 210 1851 1891 710 900 1000 224 1045 35 940 880 1000 28 28 170 210 1851 1891 686 710 800 280 1045 35 740 680 800 24 32 170 210 2147 2187 800 1000 1120 250 1293 42 1080 1000 1150 28 1) MLA 2 2) Other except MLA 2 88 9AKK105944 EN 02-2020 | ABB Motors and Generators IMB14 (IM3601) Motor size M N P S T 71 85 70 105 6 2.5 80 100 80 120 6 3 90 115 95 140 8 3 100 130 110 160 8 3.5 112 130 110 160 8 3.5 132 165 130 200 10 3.5 The table gives the main dimension in mm. For detailed drawings please see our web pages www.abb.com/motors&generators. ABB Motors and Generators | 9AKK105944 EN 02-2020 89 Dimension drawings Process performance IE4 cast iron motors L HD EC B B' Foot-mounted motor IM 1001, IM B3 H K A DS PN LS Flange-mounted motor IM 3001, IM B5 DS D F GA M S 45° Sizes 80 to 200 S M LS 45° Sizes 225 to 450 Protective roof, variant code 005 IM1001, IMB3 and IM3001, IMB5 IM1001, IMB3 IM B5 (IM3001) D Motor size 2 160 MLA 2 42 160 MLA 4-6, 42 MLB 2-4 160 MLB 6 pole 180 2-4 pole 48 180 MLA 6 - 200 55 225 55 250 60 280 SM_ 65 280 MLA - 315 SM_ 65 315 LK_ 65 355 SM_ 70 355 ML_ 70 355 LK_ 70 400 L_ 80 400 LK_ 80 450 80 GA 4-8 2 - 45 42 45 F 4-8 2 45 12 45 12 42 45 45 12 48 51.5 51.5 14 48 51.5 51.5 14 55 59 59 16 60 59 64 16 65 64 69 18 75 69 79.5 18 75 - 79.5 - 80 69 85 18 90 69 95 18 100 74.5 106 20 100 74.5 106 20 100 74.5 106 20 110 85 126 22 100 85 106 22 120 85 127 22 E L max A B B1 C HD HD K MN P S 4-8 2 4-8 2 4-8 1) 2) 12 110 110 584 584 254 210 254 108 421 - 14.5 300 250 350 19 12 110 110 681 681 254 210 254 108 421 - 14.5 300 250 350 19 12 110 110 721 721 254 210 254 108 421 - 14.5 300 250 350 19 14 110 110 726 726 279 241 279 121 461 - 14.5 300 250 350 19 14 110 110 766 766 279 241 279 121 461 - 14.5 300 250 350 19 16 110 110 822 822 318 267 305 133 528 - 18.5 350 300 400 19 18 110 140 849 879 356 286 311 149 574 - 18.5 400 350 450 19 18 140 140 884 884 406 311 349 168 626 - 24 500 450 550 19 20 140 140 1088 1088 457 368 419 190 762 - 24 500 450 550 18 20 - 140 - 1189 457 419 457 190 - 785 24 500 450 550 15 22 140 170 1174 1204 508 406 457 216 - - 28 600 550 660 23 25 140 170 1491 1521 508 508 560 216 - 880 28 600 550 660 23 28 140 210 1409 1479 610 500 560 254 958 - 35 740 680 800 23 20 140 210 1514 1584 610 560 630 254 944 958 35 740 680 800 23 28 140 210 1764 1834 610 710 900 254 958 - 35 740 680 800 23 28 170 210 1851 1891 710 900 1000 224 1045 - 35 940 880 1000 28 28 170 210 1851 1891 686 710 800 280 1045 - 35 740 680 800 24 32 170 210 2147 2187 800 1000 1120 250 1293 - 42 1080 1000 1150 28 1) Terminal box 370 2) Terminal box 750 Tolerances A, B C, CA D ± 0.8 ± 0.8 ISO k6 < Ø 50 mm ISO m6 > Ø 50 mm Tolerances F ISO h9 H + 0 -0.5 N ISO j6 The table gives the main dimension in mm. For detailed drawings please see our web pages www.abb.com/motors&generators. 90 9AKK105944 EN 02-2020 | ABB Motors and Generators Accessories Built-in brake (variant code 412) Brake design Electromagnetic disc brakes are applied by the action of a set of springs and are released when voltage is applied to the brake coil. This means that the motor will brake automatically in case of any voltage failure, as significant safety feature. The brake is always functional, irrespective of the mounting position of the brake motor. Detailed view 1 Connection box, (with rectifier, optional) 2 Manual release (optional) 3 Modified N-end shield 4 V-ring seal 5 Adapter flange for brake 6 Brake 7 V-ring seal 8 Fan cover 9 Fan Brake disc The brake linings are made of asbestos-free material. The linings are highly resistant to wear and have excellent thermal conductivity, providing consistent performance also in high temperatures. The brake disc withstands a large number of braking instances and is insensitive to dust and moisture. Note that changing from a used to a new disc will result in a different braking torque. Replacing the brake disc The brake disc must be replaced when the minimum permissible lining thickness has been reached. For minimum lining thickness, refer to the brake manufacturer's catalog. Rectifier Rectifier is a devise for DC brake applications. It is highly resistant to temperature changes as well as to voltage peaks and has additional protection for the auxiliary contact of the contactor. Thanks to its compact design, it can be placed inside the motor's terminal box. Rectifier is an optional element. Torque adjustment Reducing the torque of the brake is possible with most brake types. Refer to the brake manufacturer's catalog or contact ABB for more information. Manual release Manual release bolts are provided as standard. A manual release handle is an optional element. Manual release overrides the action of brake springs as long as it is applied. Though the manual release handle is optionally available for all motor sizes, it cannot be used in combination with the Pintsch Bamag brake type SFB. Brake rating plates The brake comes with two rating plates, one attached to the brake itself and another delivered loose, together with the motor. Variant code 412 is marked on the motor's rating plate (if it is listed among the five first codes on the motor order). ABB Motors and Generators | 9AKK105944 EN 02-2020 91 J J J 01 Foot-mounted: IM B3 (IM1001), IM B6 (IM 1051), IM B7 (IM1061), IM B8 (IM 1071), IM V5 (IM 1011), IM V6 (IM 1031). 02 Flange-mounted: IM B5 (IM 3001), IM V1 (IM 3011), IM V3 (IM 3031), IM B14 (IM 3601), IM V18 (IM 3611), IM V19 (IM 3631). 03 Foot- and flangemounted: IM B35 (IM 2001), IM V15 (IM 2011), IM V36 (IM 2031). Available brake types Motors can be fitted with recommended brakes from either Pintsch Bamag or Stromag, as seen in the tables below. Other brakes can be provided on request. Brake type KFB 10 KFB 16 KFB 25 KFB 40 KFB 63 KFB 1000 KFB 1600 On request Brake torque Nm 100 160 250 400 630 1000 1600 For motor size 160 160 - 180 180 - 225 200 - 250 225 - 280 280 - 315 315 - 355 355 - 450 Pintsch & Bamag, type KFB, IP 67, 110 V DC Electromagnetic Double-Disc Spring-Applied Brake Brake type SFB 16 SFB 25 SFB 40 SFB 63 SFB 100 SFB 160 SFB 250 SFB 400 On request Brake torque Nm 160 250 400 630 1000 1600 2500 4000 For motor size 200 - 225 200 - 225 225 - 250 250 280 - 315 315 - 355 355 - 400 400 450 Pintsch & Bamag,type SFB, IP 67, 110 V DC Electromagnetic Double-Disc Spring-Applied Brake Brake type Brake torque Nm NFF 10 100 NFF 16 160 NFF 25 250 NFF 40 400 NFF 63 630 For sizes 280-450 on request Stromag, type NFF, 110 V DC, IP66 For motor size 160 160 - 180 180 - 225 200 - 250 225 - 250 Options for the brake On new manufacture only Hand release (not possible for Pintsch Bamag brake type SFB) Rectifier Micro switch Proximity switch (not possible for Stromag brake) Standstill heater On request Special brake voltage Raised brake torque Combination with brake, separate cooling fan and/or tacho For other variants, please contact ABB Dimensions of brake motor L LC __ 01 L LC __ 02 L LC __ 03 92 9AKK105944 EN 02-2020 | ABB Motors and Generators Foot-mounted Flange-mounted Foot- and flange-mounted Motor size Poles L LC J L LC J L LC J 160 1) 2-8 773 511 372 773 511 372 773 511 372 160 2) 2-8 871 608 372 871 608 372 871 608 372 180 2-8 935 687 372 935 687 372 935 687 372 200 2-8 1011 695 460 1011 695 460 1011 695 460 225 2 1085 729 460 1085 729 460 1085 729 460 225 4-8 1115 729 460 1105 729 460 1115 729 460 250 2-8 1119 755 460 1119 755 460 1119 755 460 1)MLA-2, MLB-2, MLC-2, MLA-4, MLA-6, MLA-8 and MLB-8 -poles 2)MLD-2, MLE-2, MLB-4, MLC-4, MLD-4, MLB-6, MLC-6 and MLC-8 -poles Motor sizes 280 to 450 on request. Other dimensions same as Process performance cast iron motors sizes 180 to 250 ABB Motors and Generators | 9AKK105944 EN 02-2020 93 Accessories Separate cooling Axial fan, N-end Fan motors with an axial fan are available for motor sizes 71-450 and can be ordered can be ordered with variant code 183. The values here are given for 400 V, but technical data for other voltages can be found in MotSize. Axial fan, N-end, for motor sizes 160 - 450, IE3 Main motor Fan motor type (at 50 Hz) Voltage V at 50 Hz M3BP 160 250 M3BP 71MA 400 4 B14 M3BP 280 315 ML M3BP 80MLE 400 4 B14 M3BP 315 LK - M3BP 90LB 400 355 SM 4 B14 M3BP 355 ML, LK M3BP 400 100MLB 4 B14 Power kW 0.25 0.75 1.5 3.0 Current A 0.64 1.7 3.3 6.1 Axial fan, N-end, for motor sizes 71 - 132 Main mo- Fan motor tor type M3BP 71 Wistro 132 M3BP 80 Wistro 156 M3BP 90 Wistro 169 M3BP 100 Wistro 187 M3BP 112 Wistro 210 M3BP 132 Wistro 250 Voltage Voltage range at range at Power Cur- 50 Hz, V 60 Hz, V W rent A 380 500 380 - 575 29 0,06 220 - 290 220 - 332 28 0,1 380 500 380 - 575 34 0,06 220 - 290 220 - 332 34 0,1 380 - 380 - 575 75 0,19 500 220 - 290 220 - 332 78 0,33 380 - 380 - 575 94 0,17 500 220 - 290 220 - 332 87 0,31 380 - 380 - 575 99 0,17 500 220 - 290 220 - 332 103 0,31 380 500 380 - 575 148 0,25 220 - 290 220 - 332 146 0,45 Fan on top, N-end The non-axial fan available for motor sizes 280 and above is a Ziehl-Abbegg fan with an integrated motor. This cooling option is suited for 400 V, 50 Hz networks and can be ordered with variant code 422. MV at 50 Hz Main Fan mo- Voltmotor tor type age V M3BP 280 ZiehlAbegg RH35 400 VY 460 VY M3BP 315 ZiehlAbegg RH40 400 VY 460 VY M3BP 355 ZiehlAbegg RH45 400 VY 460 VY M3BP 400 ZiehlAbegg RH50 400 VY 460 VY M3BP 450 ZiehlAbegg RH56 400 VY 460 VY Power Freq. Hz kW 50 0.35 Current A 0.83 60 0.5 0.9 50 0.50 1.0 60 0.8 1.4 50 0.90 1.8 60 1.4 2.2 50 1.55 3.3 60 2.5 4.3 50 2.30 4.5 60 2.5 4.3 Axial fan, N-end, for motor sizes 160 - 450, IE2 Main motor Fan motor type (at 50 Hz) Voltage V at 50 Hz M3BP 160 250 M3BP 71MA 400 4 B14 M3BP 280 315 ML M3BP 80MD 400 4 B14 M3BP 315 LK - M3BP 90SLD 400 355 SM 4 B14 M3BP 355 ML M3BP 100LD 400 - 450 L 4 B14 Power Current kW A 0.25 0.64 0.75 1.83 1.5 3.0 3.0 6.3 Special motor and fan on top, N-end A special ABB fan motor type is available for motor sizes 280 and above. It is suited for environments where IP 65 is the required IP class or where the input voltage must be other than 360 420 V (50 Hz). The values here are given for 400 V, but technical data for other voltages can be found in MotSize. 94 9AKK105944 EN 02-2020 | ABB Motors and Generators The centrifugal impeller used in the fan is a ZiehlAbegg impeller.This type of cooling can be ordered with variant code 514. Special motor and fan on top, N-end, for motor sizes 280 - 450 Fan motor Voltage V Main motor type at 50 Hz M3BP 280 M3BP 80 400 - 315 MD 4 B34 M3BP 355 M3BP 400 M3BP 90 400 SLD 4 B34 M3BP 100 400 LD 4 B34 M3BP 450 M3BP 112 400 MB 4 B34 Power kW Current A 0.75 1.83 1.5 3.0 3.0 6.3 4.0 8.2 ABB Motors and Generators | 9AKK105944 EN 02-2020 95 Accessories Silencer for motor sizes 280 - 450 LV 80 AV O O S DV LVT Both foot-mounted and flange-mounted motors can be fitted with a silencer to reduce noise level by about 5 - 6 dB(A). The silencer is painted blue and made of 2 mm steel sheet. The sound absorbing material is 40 mm thick polyurethane foam. On the rim there is a rubber strip for sealing on the floor. The silencer fits loosely over the motor. The variant code for ordering a silencer is 055. Motor size AV LV LVT DV O1) 280 SM_ 681 1010 1090 616 50 315 SM_ 760 1094 1191 697 60 315 ML_ 760 1205 1302 697 60 315 LK_ 760 1411 1508 697 60 355 SM_ 850 1335 1441 777 65 355 ML_ 850 1440 1546 777 65 355 LK_ 850 1690 1796 777 65 400 L_ 938 1750 1873 866 75 400 LK_ 938 1750 1873 866 75 450 L_ 1050 2110 2230 990 80 1) Clearance for motor cooling. 2) Clearance for removal of silencer. Note: The dimensions are only valid for standard foot-mounted motors. S2) 762 852 852 852 958 958 958 1045 1045 1045 Weight kg 38 47 51 58 62 67 77 88 88 120 96 9AKK105944 EN 02-2020 | ABB Motors and Generators Accessories Slide rails for motor sizes 160 - 250 E H B N 1 M Ymax. L Xmax. 3 5 F O D C 2 4 G A 1 Motor | 2 Rail | 3 Movable adjusting bolt | 4 Fixing bolt, motor | 5 Plate A set of slide rails includes two complete rails with screws for mounting the motor on the rails. Screws for mounting the rails on the foundation are not included.Slide rails have unmachined lower surfaces and should, before tightening down, be supporter in a suitable manner. Slide rails can be ordered with article numbers shown in the table. Article no. Weight/ Motor size Type 3GZV103001- A B C D E F G H L M N O Xmax Ymax rail kg Frame sizes 71 to 132 on request 160 - 180 TT180/12 -14 200 - 225 TT225/16 -15 250 TT280/20 -16 75 42 700 630 57 17 26 M12 120 M12 50 - 520 82 50 864 800 68 17 27 M16 140 M16 65 17 670 116 70 1072 1000 90 20 27 M18 150 M20 80 20 870 580 12.0 740 20.4 940 43.0 ABB Motors and Generators | 9AKK105944 EN 02-2020 97 Accessories Slide rails for motor sizes 280 - 400 d h (e2) l1 l2 l3 a b1 c e1 e3 g c b2 e4 Slide rails for motor sizes 280 - 315. d h (e2) l2 l1 l2 l3 f2 a b4 c1 e1 e3 g c1 b1 h1 h2 f f1 b1 b2 e4 b5 Slide rails for motor sizes 355 - 400. Note: Slide rails that do not fulfill the DIN standard are available for motor size 450 on request. A set of slide rails includes two complete rails with screws for mounting the motor on the rails. Screws for mounting the rails on the foundation are not included. Slide rails have unmachined lower surfaces and should be supported in a suitable manner before tightening down. Slide rails can be ordered with article numbers shown in the table. Motor size Article no. 280 3GZF334730-55 315 3GZF334730-56 355 - 400 3GZF334730-57 l1 l2 l3 a 800 600 900 16 1000 720 1100 16 1250 485 1350 16 h b1 b2 c d 75 100 120 35 28 80 120 140 40 28 80 120 140 35 28 Bolts Horizontal Weight e1 e2 e3 e4 to feet bolts 100 100 200 165 M20x90 M24x300 140 140 240 190 M24x100 M24x300 140 140 240 190 M24x100 M24x300 kg/2 pc 50 80 90 98 9AKK105944 EN 02-2020 | ABB Motors and Generators Motors in brief Cast iron motors, sizes 71 - 132 Motor size Stator and end shields Material Paint color shade Corrosion class Feet Bearings D-end N-end Axially locked bearings Bearing seals D-end N-end Lubrication Measuring nipples for condition monitoring of the bearings Rating plate Material Terminal box Frame and cover Corrosion class Cover screws Connections Threaded openings Terminals Cable glands Fan Material Fan cover Material Paint color shade Corrosion class Stator winding Material Insulation Winding protection Rotor winding Material Balancing method Keyway Drain holes Enclosure Cooling method *) 6206-2Z/C3 in IE3 71 80 90 Cast iron Munsell blue 8B 4.5/3.25 C3 (medium) Integrated cast iron feet 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 Locked at D-end V-ring Labyrinth seal in IE2, V-ring in IE3 Permanently lubricated shielded bearings Not included 100 6206-2Z/C3 6205-2Z/C3 Stainless steel Cast iron C3 (medium) Zinc-electroplated steel 2xM16 2xM25 2xM25 6 terminals for connection with cable lugs (not included) Cable flange included, glands as option Glass-fiber reinforced polypropylene Steel Munsell blue 8B 4.5/3.25 C3 (medium) Copper Insulation class F. Temperature rise class B unless otherwise stated. 3 PTC thermistors, 150 °C Pressure die-cast aluminum Half-key balancing as standard Closed keyway Drain holes with closable plastic plugs, open on delivery IP 55 IC 411 112 132 6206-2Z/C 6208-2Z/C3 6205-2Z/C3 *) 6208-2Z/C3 ABB Motors and Generators | 9AKK105944 EN 02-2020 99 Motors in brief Cast iron motors, sizes 160 - 250 Motor size Stator and end shields Material Paint color shade Corrosion class Feet Material Bearings D-end N-end Axially locked bearings Bearing seals D-end N-end Lubrication Measuring nipples for condition monitoring of the bearings Rating plate Material Terminal box Frame and cover Corrosion class Cover screws Connections Cable entries Terminals Cable glands Fan Material Fan cover Material Paint color shade Corrosion class Stator winding Material Insulation Winding protection Rotor winding Material Balancing method Keyway Drain holes Enclosure Cooling method 160 180 200 225 Cast iron Munsell blue 8B 4.5/3.25 C3 (medium) Integrated cast iron feet, bolted feet when terminal box on LHS/RHS 6309/C3 6310/C3 6312/C3 6313/C3 6209/C3 6209/C3 6210/C3 6212/C3 Locked at D-end Gamma-ring Gamma-ring Regreasable bearings, regreasing nipples M6x1 Included Stainless steel Cast iron C3 (medium) Zinc-electroplated steel 2xM40, 2xM20 2xM63, 2xM20 6 terminals for connection with cable lugs (not included) Cable flange included, glands as option Glass-fiber reinforced polypropylene Steel Munsell blue 8B 4.5/3.25 C3 (medium) Copper Insulation class F. Temperature rise class B unless otherwise stated. 3 PTC thermistors, 150 °C Pressure die-cast aluminum Half-key balancing as standard Closed keyway Drain holes with closable plastic plugs, open on delivery IP 55 IC 411 250 6315/C3 6213/C3 100 9AKK105944 EN 02-2020 | ABB Motors and Generators Motors in brief Cast iron motors, sizes 280 - 450 Motor size Stator and end shields Material Paint color shade Corrosion class Feet Material Bearings D-end 2-pole 4-12-pole N-end 2-pole 4-12-pole Axially locked bearings Bearing seals D-end N-end Lubrication Measuring nipples for condition monitoring of the bearings Rating plate Material Terminal box Frame and cover Corrosion class Cover screws Connections Cableentries 2-4-pole 6-8-pole Fan Fan cover Stator winding Rotor winding Balancing method Keyway Drain holes Enclosure Cooling method Terminals Cable glands Material Material Paint color shade Corrosion class Material Insulation Winding protection Material 280 315 355 Cast iron Munsell blue 8B 4.5/3.25 C3 (medium) Integrated cast iron feet 6316/C3 6316/C3 6316M/C3 6316/C3 6319/C3 6322/C3 6316/C3 6316/C3 6316M/C3 6316/C3 6316/C3 6316/C3 Locked at D-end V-ring or labyrinth seal V-ring or labyrinth seal Regreasable bearings, regreasing nipples M10x1 Included 400 450 6317M/C3 6324/C3 6317M/C3 6319/C3 6317M/C3 6326M/C3 6317M/C3 6322/C3 Stainless steel Cast iron Cover steel C3 (medium) Steel Zinc-electroplated steel 2xM63+2xM20 2xM63, 2xØ4860+2xM20 2xØ48-60, 60-80, 2xM20 2xØ60-80 (2-6-pole), 2xØ60-80, 2xM20 2xM2+0 2xØ32-49, 48-60, 2M20 2xØ48-60 (8-pole), 2xM20 See section Standard terminal box for detailed information. 6 terminals for connection with cable lugs (not included) Cable flange, glands as option Glass-fiber reinforced polypropylene Steel Munsell blue 8B 4.5/3.25 C3 (medium) Copper Insulation class F. Temperature rise class B unless otherwise stated. 3 PTC thermistors, 155 °C Pressure die-cast aluminum Half-key balancing Open keyway Drain holes with closable plastic plugs, open on delivery IP 55 IC 411 ABB Motors and Generators | 9AKK105944 EN 02-2020 101 Motor construction Exploded view, frame size 315 1 Stator frame 2 End shield, D-end 3 Screws for end shield, D-end 4 End shield, N-end 5 Screws for end shield, N-end 6 Rotor with shaft 7 Key, D-end 8 Terminal box 9 Terminal board 10 Intermediate flange 11 Screws for terminal box cover 12 Outer bearing cover, D-end 13 Valve disc with labyrinth seal, D-end; standard in 2-pole motors, V-ring in 4-8 pole motors 14 Bearing, D-end 15 Inner bearing cover, D-end 16 Screws for bearing cover 17 Outer bearing cover, N-end 18 Seal, N-end 19 Wave spring 20 Valve disc, N-end 21 Bearing, N-end 22 Inner bearing cover, N-end 23 Screws for bearing cover 24 Fan 25 Fan cover 26 Screws for fan cover 27 Rating plate 28 Lubrication plate 29 Grease nipple, D-end 30 Grease nipple, N-end 31 SPM nipple, D-end 32 SPM nipple, N-end 102 9AKK105944 EN 02-2020 | ABB Motors and Generators Low voltage Process performance aluminum motors 104 Ordering information 105 Rating plates 106 Technical data IE2 106 400 V, 50 Hz 111 460V, 60Hz 115 Technical data IE3 115 400 V, 50 Hz 120 460V, 60Hz 123 Variant codes 128 Mechanical design 128 Motor frame and drain holes 129 Bearings 139 Terminal box 142 Dimension drawings 142 IE2 aluminum motors 143 IE3 aluminum motors, J/L-generation 144 IE3 aluminum motors, K-generation 145 Accessories 145 Slide rails 146 Aluminum motors in brief 146 Motor sizes 63 - 132 147 Motor sizes 160 - 280 ABB Motors and Generators | 9AKK105944 EN 02-2020 103 Ordering information Explanation of the product code Motor type Motor size Product code Code for mounting arrangement, Voltage and frequency code, Generation code followed by variant codes M3AA 112MB 3GAA 111 320 - ADE, 122, 003 etc. 1 2 3 4 5 67 8 9 10 11 12 13 14... Positions 1 to 4 3GAA: Totally enclosed motor with aluminum stator frame Positions 5 and 6 IEC size 06: 63 07: 71 08: 80 09: 90 10: 100 11: 112 13: 132 IEC size 16: 160 18: 180 20: 200 22: 225 25: 250 28: 280 Position 7 Pole pairs 1: 2 poles 2: 4 poles 3: 6 poles 4: 8 poles 5: 10 poles 6: 12 poles 7: > 12 poles 8: Two-speed motors 9: Multi-speed motors Positions 8 to 10 Running number Position 11 - (dash) Position 11 - (dash) Position 12 (marked with black dot in data tables) Mounting arrangement A: Foot-mounted motor B: Flange-mounted motor. Large flange with clearance holes. C: Flange-mounted motor. Small flange with tapped holes. F: Foot- and flange-mounted motor. Special flange. Position 12 (marked with black dot in data tables) H: Foot- and flange-mounted motor. Large flange with clearance holes. J: Foot- and flange-mounted motor. Small flange with tapped holes. N: Flange-mounted (CI ring flange FF) P: Foot-and flange-mounted motor (CI ring flange FF) V: Flange-mounted motor. Special flange. Position 13 (marked with black dot in data tables) Voltage and frequency code Single-speed motors B: 380 V 50 Hz D: 400 V, 415 V, 690 VY 50 Hz E: 500 V 50 Hz F: 500 VY 50 Hz S: 230 V, 400 VY, 415 VY 50 Hz T: 660 V 50 Hz U: 690 V 50 Hz X: Other rated voltage, connection or frequency, 690 V maximum Two-speed motors A: 220 V 50 Hz B: 380 V 50 Hz D: 400 V 50 Hz E: 500 V 50 Hz S: 230 V 50 Hz X: Other rated voltage, connection or frequency, 690 V maximum Remark: For voltage code X the variant code "209 Non-standard voltage or frequency (special winding)" must be ordered. Position 14 Version A, B, C...:Generation code followed by variant codes Efficiency values are given according to IEC 600342-1; 2014 For detailed dimension drawings please see our web-pages `www.abb.com/motors&generators' or contact ABB. 104 9AKK105944 EN 02-2020 | ABB Motors and Generators Rating plates The motor's main rating plate shows the motor's 01 Motor sizes 71 to 80. performance values with various connections at 02 Motor sizes 90 to 132. nominal speed. The rating plate also shows the ef- 03 Motor sizes 160 to 280. ficiency level (IE2, IE3, or IE4), year of manufacture, and the lowest nominal efficiency at 100, 75, and 50 % nominal load. The material of the rating plate is aluminum as standard. __ 01 __ 02 __ 03 ABB Motors and Generators | 9AKK105944 EN 02-2020 105 Technical data, 400 V 50 Hz IE2 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3000 r/min = 2 poles 0.18 M3AA 63A 2 3GAA061311-··E 0.25 M3AA 63B 2 3GAA061312-··E 0.37 M3AA 71A 2 3GAA071311-··E 0.55 M3AA 71B 2 3GAA071312-··E 0.75 M3AA 80B 2 3GAA081312-··E 1.1 M3AA 80C 2 3GAA081313-··E 1.5 M3AA 90L 2 3GAA091500-··E 2.2 M3AA 90LB 2 3GAA091520-··E 3 M3AA 100LB 2 3GAA101520-··E 4 M3AA 112MB 2 3GAA111320-··E 5.5 M3AA 132SB 2 3GAA131120-··E 7.5 M3AA 132SC 2 3GAA131130-··E 11 M3AA 160MLA 2 3GAA161410-··G 15 M3AA 160MLB 2 3GAA161420-··G 18.5 M3AA 160MLC 2 3GAA161430-··G 22 M3AA 180MLA 2 3GAA181410-··G 30 M3AA 200MLA 2 3GAA201410-··G 37 M3AA 200MLB 2 3GAA201420-··G 45 M3AA 225SMA 2 3GAA221210-··G 55 M3AA 250SMA 2 3GAA251210-··G 75 M3AA 280SMA 2 3GAA281210-··G 90 1) M3AA 280SMB 2 3GAA281220-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 2790 2790 2800 2790 2895 2875 2900 2870 2920 2885 2915 2915 2938 2934 2932 2952 2956 2959 2961 2967 2968 2971 400 V 50 Hz 67.3 65.1 71.4 70.1 73.8 75.8 78.4 79.8 80.6 80.4 80.6 80.4 84.1 85.0 84.6 85.7 86.4 86.1 86.1 87.0 88.0 88.2 88.5 89.2 90.6 91.5 91.5 92.5 92.0 93.1 92.2 92.8 93.1 93.5 93.4 93.7 93.6 93.9 94.1 94.4 94.4 94.7 94.9 95.2 58.2 64.7 73.9 78.7 77.3 77.9 83.5 84.9 84.0 88.0 86.9 88.6 91.1 92.2 93.1 92.2 92.8 92.9 93.1 93.8 94.2 94.7 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.75 0.51 4.5 0.61 2.4 2.6 0.00015 0.76 0.66 4.8 0.86 2.8 2.7 0.00017 0.76 0.95 4.9 1.26 2.7 2.7 0.00035 0.78 1.29 5.3 1.88 2.9 2.8 0.00045 0.79 1.7 8.1 2.4 3.7 3.9 0.0009 0.80 2.4 7.8 3.6 3.6 3.5 0.0012 0.86 2.9 7.6 4.9 2.5 3.3 0.0024 0.86 4.4 6.9 7.3 2.8 3.2 0.0027 0.86 5.8 9.3 9.8 3.3 3.9 0.005 0.88 7.6 7.6 13.2 2.5 2.8 0.0062 0.82 11 7.9 18 2.6 3.6 0.016 0.88 13.6 7.6 24.5 2.2 3.2 0.022 0.90 19.2 7.5 35.7 2.4 3.1 0.044 0.90 26 7.5 48.8 2.5 3.3 0.053 0.92 31.5 7.5 60.2 2.9 3.4 0.063 0.87 39.5 7.7 71.1 2.8 3.3 0.076 0.90 51.4 7.7 96.9 2.7 3.1 0.178 0.90 63.5 8.2 119 3.0 3.3 0.196 0.88 78.8 6.7 145 2.5 2.5 0.244 0.88 95.8 6.8 177 2.2 2.7 0.507 0.89 128 7.1 241 2.5 2.8 0.583 0.89 153 7.8 289 2.6 3.2 0.644 Weight kg Sound pressure Level LPA dB 4 60 4.2 61 4.9 58 5.9 58 10.5 60 11 60 16 60 18 63 25 62 30 68 52 73 52 73 91 69 105 69 123 69 132 69 210 72 225 72 263 74 304 75 389 75 425 75 1) Temperature rise class F 106 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE2 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3000 r/min = 2 poles 11 M3AA 132SMF 2 3GAA131260-··E 15 M3AA 132SMG 2 3GAA131270-··E 18.5 M3AA 132SMJ 2 3GAA131290-··E 22 M3AA 160MLD 2 3GAA161440-··G 27 M3AA 160MLE 2 3GAA161450-··G 30 M3AA 180MLB 2 3GAA181420-··G 45 M3AA 200MLC 2 3GAA201430-··G 55 1) M3AA 200MLD 2 3GAA201440-··G 55 M3AA 225SMB 2 3GAA221220-··G 75 1) M3AA 225SMC 2 3GAA221230-··G 75 1) M3AA 225SMD 2 3GAA221240-··G 75 M3AA 250SMB 2 3GAA251220-··G 80 1) M3AA 225SMD 2 3GAA221240-··G 90 1) M3AA 250SMC 2 3GAA251230-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 2900 2905 2895 2933 2939 2950 2957 2953 2961 2969 2967 2970 2964 2971 400 V 50 Hz 90.3 90.5 90.4 90.8 91.1 92.0 91.7 92.8 92.2 93.1 92.7 93.5 93.3 93.8 93.8 94.4 93.9 94.3 94.4 94.6 94.4 94.6 94.5 94.8 94.4 94.8 95.0 95.3 89.4 90.0 92.1 92.8 93.1 93.3 93.2 94.3 93.6 94.0 94.0 94.3 94.3 94.9 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.87 20.2 8.5 36.2 2.7 3.7 0.0186 0.84 28.5 9.1 49.3 3.3 4.0 0.02 0.89 32.9 9.7 61 3.2 4.3 0.0256 0.90 38 8.1 71.6 3.2 3.6 0.063 0.90 46.4 8.8 87.7 3.4 3.8 0.072 0.88 53 7.9 97.1 2.8 3.3 0.092 0.90 78.2 8.1 145 3.1 3.3 0.196 0.89 95 7.8 177 2.9 3.3 0.217 0.88 96 6.5 177 2.4 2.5 0.274 0.84 136 7.4 241 3.2 3.1 0.309 0.87 131 7.7 241 3.2 3.0 0.329 0.89 128 7.6 241 2.8 3.1 0.583 0.87 140 7.3 257 3.0 2.8 0.329 0.89 153 7.6 289 2.5 3.1 0.644 Weight kg Sound pressure Level LPA dB 77 68 81 69 93 68 123 69 145 69 149 69 225 72 241 72 286 74 312 74 317 74 351 75 317 74 386 75 1) Temperature rise class F ABB Motors and Generators | 9AKK105944 EN 02-2020 107 Technical data, 400 V 50 Hz IE2 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1500 r/min = 4 poles 0.12 M3AA 63A 4 3GAA062311-··E 0.18 M3AA 63B 4 3GAA062312-··E 0.25 M3AA 71A 4 3GAA072311-··E 0.37 M3AA 71B 4 3GAA072312-··E 0.55 M3AA 80A 4 3GAA082311-··E 0.75 M3AA 80E 4 3GAA082315-··E 1.1 M3AA 90LB 4 3GAA092520-··E 1.5 M3AA 90LD 4 3GAA092540-··E 2.2 M3AA 100LC 4 3GAA102530-··E 3 M3AA 100LD 4 3GAA102540-··E 4 M3AA 112MB 4 3GAA112320-··E 5.5 M3AA 132M 4 3GAA132300-··E 7.5 M3AA 132MA 4 3GAA132310-··E 11 M3AA 160MLA 4 3GAA162410-··G 15 M3AA 160MLB 4 3GAA162420-··G 18.5 M3AA 180MLA 4 3GAA182410-··G 22 M3AA 180MLB 4 3GAA182420-··G 30 M3AA 200MLA 4 3GAA202410-··G 37 M3AA 225SMA 4 3GAA222210-··G 45 M3AA 225SMB 4 3GAA222220-··G 55 M3AA 250SMA 4 3GAA252210-··G 75 M3AA 280SMA 4 3GAA282210-··G 85 M3AA 280SMB 4 3GAA282220-··G 90 1) M3AA 280SMB 4 3GAA282220-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1360 1370 1365 1375 1375 1425 1435 1435 1450 1445 1445 1465 1460 1466 1470 1477 1475 1480 1479 1480 1480 1478 1480 1478 400 V 50 Hz 55.0 51.3 63.5 61.0 65.1 66.0 69.7 71.9 72.8 76.1 79.8 80.4 83.7 83.7 84.2 84.1 86.4 86.2 85.7 86.1 86.7 86.5 89.0 89.5 88.7 89.4 90.4 91.6 91.4 92.4 91.9 92.9 92.3 93.3 93.2 94.0 93.4 93.9 93.9 94.3 94.4 94.9 94.3 94.9 94.8 95.3 94.6 95.4 43.0 54.3 62.7 71.1 75.2 77.9 81.7 81.9 84.1 85.1 85.2 88.6 88.9 91.4 92.2 92.7 93.2 93.7 93.4 93.9 94.6 94.6 95.0 95.2 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.64 0.49 3.2 0.84 2.4 2.5 0.00027 0.61 0.67 3.7 1.25 2.8 2.9 0.00034 0.76 0.72 4.0 1.74 2.0 2.1 0.00066 0.79 0.96 3.8 2.5 2.0 2.2 0.0008 0.77 1.41 4.5 3.8 1.8 2.2 0.0013 0.72 1.88 6.6 5 3.5 3.6 0.002 0.78 2.4 6.6 7.3 2.9 3.2 0.0043 0.76 3.3 7.0 9.9 3.1 3.5 0.0048 0.79 4.6 7.3 14.4 2.8 3.4 0.009 0.79 6.3 7.0 19.8 2.4 3.0 0.011 0.75 8.8 7.3 26.4 3.1 3.4 0.0126 0.79 10.9 6.3 36 1.9 2.6 0.038 0.79 14.7 6.4 49 1.8 2.6 0.048 0.84 20.9 6.8 71.6 2.2 2.8 0.081 0.83 28.5 7.1 97.4 2.6 3.0 0.099 0.84 34.5 7.2 119 2.6 2.9 0.166 0.84 40.9 7.3 142 2.6 3.0 0.195 0.84 55.2 7.4 193 2.8 3.0 0.309 0.84 68 7.1 238 2.6 2.9 0.356 0.85 81.3 7.5 290 2.8 3.2 0.44 0.85 98.9 7.0 354 2.6 2.9 0.765 0.85 135 7.1 484 2.8 3.0 0.866 0.84 153 8.0 548 3.4 3.6 0.941 0.84 163 7.7 581 3.2 3.4 0.941 Weight kg Sound pressure Level LPA dB 3.7 51 4.2 54 5.2 45 5.9 45 8.5 50 15 54 16 50 17 50 25 54 28 63 34 64 48 66 59 63 99 62 118 62 146 62 163 62 218 63 240 66 273 66 314 67 389 67 418 67 418 67 1) Temperature rise class F Output kW Motor type Product code 1500 r/min = 4 poles 15 M3AA 132SMH 4 3GAA132280-··E 18.5 M3AA 160MLC 4 3GAA162430-··G 22 1) M3AA 160MLD 4 3GAA162440-··G 30 1) M3AA 180MLC 4 3GAA182430-··G 37 M3AA 200MLB 4 3GAA202420-··G 45 1) M3AA 200MLC 4 3GAA202430-··G 55 M3AA 225SMC 4 3GAA222230-··G 64 M3AA 225SMD 4 3GAA222240-··G 75 1) M3AA 250SMB 4 3GAA252220-··G 90 1) M3AA 250SMC 4 3GAA252230-··G 1) Temperature rise class F Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1455 1469 1464 1474 1479 1479 1478 1480 1478 1478 400 V 50 Hz 90.6 91.0 91.4 92.5 91.6 92.6 92.3 93.5 93.4 94.4 93.6 94.4 94.0 94.7 94.2 94.6 94.4 95.1 94.6 95.3 90.3 92.3 92.7 93.5 94.4 94.2 94.5 94.1 94.8 95.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.77 29.8 7.1 98.4 2.4 2.9 0.0517 0.84 34.7 7.6 120 3.0 3.2 0.11 0.85 41.3 6.9 143 2.5 2.9 0.125 0.83 56.5 7.3 194 2.7 2.9 0.217 0.85 67.2 7.1 238 2.6 2.9 0.343 0.83 83.6 7.5 290 2.9 3.2 0.366 0.85 99.3 7.4 355 2.9 3.1 0.474 0.85 115 8.2 412 3.3 3.3 0.542 0.85 134 7.3 484 2.8 3.1 0.866 0.84 163 7.4 581 3.1 3.3 0.941 Weight kg Sound pressure Level LPA dB 82 67 127 62 140 62 177 62 234 63 246 63 287 66 314 66 350 67 377 67 108 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE2 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1000 r/min = 6 poles 0.09 M3AA 63A 6 3GAA063311-··E 0.12 M3AA 63B 6 3GAA063312-··E 0.18 M3AA 71A 6 3GAA073311-··E 0.25 M3AA 71B 6 3GAA073312-··E 0.37 M3AA 80A 6 3GAA083311-··E 0.55 M3AA 80B 6 3GAA083312-··E 0.75 M3AA 90LB 6 3GAA093520-··E 1.1 M3AA 90LD 6 3GAA093540-··E 1.5 M3AA 100LC 6 3GAA103530-··E 2.2 M3AA 112MB 6 3GAA113320-··E 3 M3AA 132S 6 3GAA133100-··E 4 M3AA 132MB 6 3GAA133320-··E 5.5 M3AA 132MC 6 3GAA133330-··E 7.5 M3AA 160MLA 6 3GAA163410-··G 11 M3AA 160MLB 6 3GAA163420-··G 15 M3AA 180MLA 6 3GAA183410-··G 18.5 M3AA 200MLA 6 3GAA203410-··G 22 M3AA 200MLB 6 3GAA203420-··G 30 M3AA 225SMA 6 3GAA223210-··G 37 M3AA 250SMA 6 3GAA253210-··G 45 1) M3AA 280SMA 6 3GAA283210-··G 55 1) M3AA 280SMB 6 3GAA283220-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 890 50.7 48.5 42.0 890 52.3 48.8 41.5 885 59.5 61.1 56.5 895 64.0 63.6 59.5 905 68.0 70.7 68.3 905 68.7 71.8 69.7 930 77.6 78.0 75.6 935 78.2 79.2 77.5 945 80.3 81.4 80.7 955 81.9 81.8 79.2 960 83.3 82.9 80.5 975 86.4 85.8 83.1 965 86.1 85.6 83.0 975 88.5 89.8 89.7 972 89.3 90.6 90.5 977 90.5 91.5 91.0 988 91.6 92.3 91.7 987 92.0 92.9 92.8 986 92.6 93.3 92.8 989 93.1 93.8 93.4 988 93.2 94.0 93.9 988 93.2 94.1 94.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.62 0.41 2.8 0.96 2.0 2.2 0.00042 0.60 0.55 3.0 1.29 2.2 2.4 0.00052 0.71 0.61 3.1 1.94 1.7 1.9 0.00092 0.71 0.79 3.3 2.6 2.2 2.2 0.0012 0.73 1.07 3.6 3.9 1.6 2.1 0.002 0.73 1.58 3.3 5.8 1.6 1.8 0.0026 0.71 1.96 4.0 7.7 2.0 2.3 0.0048 0.66 2.94 4.2 11.2 2.2 2.6 0.0056 0.73 3.6 3.9 15.1 1.7 2.0 0.009 0.72 5.3 5.2 21.9 1.8 2.2 0.01 0.65 7.69 4.3 29.8 1.6 2.3 0.031 0.70 9.4 7.3 39.2 2.1 4.4 0.045 0.67 13.3 6.2 54.3 2.5 2.8 0.049 0.79 15.4 7.4 73.4 1.7 3.2 0.087 0.79 22.5 7.5 108 1.9 2.9 0.114 0.77 31 5.8 146 1.8 2.7 0.168 0.80 36.4 6.7 178 2.3 2.9 0.382 0.82 42 6.6 212 2.2 2.8 0.448 0.83 56.2 7.0 290 2.6 2.9 0.663 0.82 69.9 6.8 357 2.4 2.7 1.13 0.84 82.9 6.8 434 2.4 2.6 1.37 0.84 101 7.1 531 2.6 2.8 1.5 Weight kg Sound pressure Level LPA dB 4.2 48 4.5 53 5.5 42 6.5 42 9 47 10 47 18 44 20 44 26 49 34 56 46 57 54 57 59 61 98 59 125 59 148 59 196 63 218 63 266 63 294 63 378 63 404 63 1) Temperature rise class F Output kW Motor type Product code 1000 r/min = 6 poles 15 M3AA 160MLC 6 3GAA163430-··G 18.5 M3AA 180MLB 6 3GAA183420-··G 30 1) M3AA 200MLC 6 3GAA203430-··G 37 M3AA 225SMB 6 3GAA223220-··G 45 1) M3AA 225SMC 6 3GAA223230-··G 45 M3AA 250SMB 6 3GAA253220-··G 55 1) M3AA 250SMC 6 3GAA253230-··G 1) Temperature rise class F Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 971 89.7 91.2 975 90.7 92.0 985 92.0 93.1 985 93.1 94.0 984 92.6 93.9 989 93.4 94.1 988 93.2 94.1 91.2 92.0 92.9 94.0 94.0 93.9 94.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.77 31.3 7.3 147 1.8 3.6 0.131 0.79 37.2 5.8 181 1.7 2.7 0.198 0.83 56.7 6.9 290 2.3 2.8 0.531 0.83 69.1 6.6 358 2.3 2.6 0.821 0.83 84.4 6.4 436 2.3 2.6 0.821 0.83 83.7 7.0 434 2.5 2.7 1.37 0.84 101 7.1 531 2.6 2.8 1.5 Weight kg Sound pressure Level LPA dB 138 59 162 59 245 63 300 63 300 63 341 63 367 63 ABB Motors and Generators | 9AKK105944 EN 02-2020 109 Technical data, 400 V 50 Hz IE2 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 750 r/min = 8 poles 0.09 M3AA 71A 8 3GAA074001-··E 0.12 M3AA 71B 8 3GAA074002-··E 0.18 M3AA 80A 8 3GAA084001-··E 0.25 M3AA 80B 8 3GAA084002-··E 0.37 M3AA 90S 8 3GAA094100-··E 0.55 M3AA 90L 8 3GAA094500-··E 0.75 M3AA 100LA 8 3GAA104510-··E 1.1 M3AA 100LB 8 3GAA104520-··E 2.2 M3AA 132S 8 3GAA134100-··E 3 M3AA 132M 8 3GAA134300-··E 4 M3AA 160 MLA 8 3GAA164410-··G 5.5 M3AA 160 MLB 8 3GAA164420-··G 11 M3AA 180 MLA 8 3GAA184410-··G 15 M3AA 200 MLA 8 3GAA204410-··G 18.5 M3AA 225 SMA 8 3GAA224210-··G 22 M3AA 225 SMB 8 3GAA224220-··G 30 M3AA 250 SMA 8 3GAA254210-··G 37 M3AA 280 SMA 8 3GAA284210-··E 75 M3AA 160 MLC 8 3GAA164430-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 675 48.8 45.2 665 51.5 49.0 690 57.2 55.4 690 61.4 60.0 695 59.4 55.9 660 61.7 59.5 720 70.7 67.1 695 76.0 74.9 715 77.7 79.2 715 79.3 78.8 728 84.0 85.1 726 84.6 85.9 731 86.9 88.5 737 90.1 91.3 739 91.0 92.0 738 91.6 92.3 742 92.3 92.8 740 92.2 93.0 727 86.0 87.3 37.8 41.9 48.8 54.0 47.8 53.0 59.9 70.9 77.6 75.5 83.6 84.8 87.9 90.8 91.5 92.0 92.2 92.6 86.5 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.57 0.46 2.5 1.27 2.2 2.1 0.00092 0.60 0.56 2.5 1.72 2.2 2.1 0.0012 0.61 0.74 2.9 2.4 2.3 2.3 0.0018 0.60 0.97 3.1 3.4 2.5 2.5 0.0024 0.54 1.6 2.7 5 1.7 2.1 0.0032 0.58 2.3 2.5 7.6 1.5 1.6 0.0043 0.47 3.2 3.9 9.9 2.5 3.3 0.0069 0.66 3.1 3.4 15.1 1.7 2.2 0.0082 0.65 6.2 3.4 29.3 1.3 1.9 0.031 0.64 8.5 3.2 40 1.2 1.8 0.037 0.67 10.2 5.4 52.4 1.5 2.6 0.068 0.67 13.9 5.6 72.3 1.4 2.6 0.085 0.67 27.3 4.4 143 1.8 2.6 0.214 0.74 32.4 5.3 194 2.0 2.4 0.45 0.73 40.1 5.2 239 2.0 2.3 0.669 0.74 46.8 5.5 284 2.0 2.3 0.722 0.71 66 5.8 386 2.6 2.4 1.4 0.74 78.1 5.6 477 2.4 2.3 1.51 0.65 19.3 4.7 98.5 1.5 2.8 0.132 Weight kg Sound pressure Level LPA dB 5.5 40 6.5 43 8.5 45 9.5 50 13 52 16 52 20 46 23 53 46 56 53 58 84 59 98 59 175 59 217 60 266 63 279 63 340 63 403 63 137 59 Output kW Motor type Product code 750 r/min = 8 poles 0.18 M3AA 71C 8 3GAA074003-··E 0.37 M3AA 80C 8 3GAA084003-··E 0.75 1) M3AA 90LF 8 3GAA094560-··E 1.5 1) M3AA 100LG 8 3GAA104570-··E 3.8 1) M3AA 132MF 8 3GAA134360-··E 18.5 M3AA 200 MLB 8 3GAA204420-··E 30 M3AA 225 SMC 8 3GAA224230-··E 37 M3AA 250 SMB 8 3GAA254220-··E 45 1) M3AA 250 SMC 8 3GAA254230-··G 1) Temperature rise class F Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 660 49.8 48.5 41.7 685 63.1 63.2 58.1 635 58.5 57.8 51.2 685 70.7 70.9 67.3 710 76.7 79.3 78.1 739 90.1 90.9 90.3 737 91.6 92.6 92.4 740 92.7 93.6 93.4 738 92.2 93.4 93.4 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.63 0.82 2.7 2.6 2.1 2.0 0.0015 0.62 1.36 3.3 5.1 2.3 2.3 0.0031 0.60 3.1 2.7 10.5 1.7 2.0 0.0048 0.64 4.7 3.1 20.9 1.9 2.0 0.009 0.68 10.5 3.7 51.1 1.4 2.5 0.049 0.74 40 5.4 239 2.1 2.3 0.53 0.73 64.7 5.6 388 2.3 2.4 0.828 0.73 78.9 5.4 477 2.6 2.3 1.51 0.74 95.1 5.6 582 2.3 2.4 1.51 Weight kg Sound pressure Level LPA dB 7 40 11 45 18 43 26 46 54 68 245 60 300 63 367 63 367 63 110 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 460 V 60 Hz IE2 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3600 r/min = 2 poles 0.25 M3AA 63B 2 3GAA061312-··E 0.37 M3AA 71A 2 3GAA071311-··E 0.55 M3AA 71B 2 3GAA071312-··E 0.75 M3AA 80B 2 3GAA081312-··E 1.1 M3AA 80C 2 3GAA081313-··E 1.5 M3AA 90L 2 3GAA091500-··E 2.2 M3AA 90LB 2 3GAA091520-··E 3 M3AA 100LB 2 3GAA101520-··E 4 M3AA 112MB 2 3GAA111320-··E 5.5 M3AA 132SB 2 3GAA131120-··E 7.5 M3AA 132SC 2 3GAA131130-··E 11 M3AA 160MLA 2 3GAA161410-··G 15 M3AA 160MLB 2 3GAA161420-··G 18.5 M3AA 160MLC 2 3GAA161430-··G 22 M3AA 180MLA 2 3GAA181410-··G 30 M3AA 200MLA 2 3GAA201410-··G 37 M3AA 200MLB 2 3GAA201420-··G 45 M3AA 225SMA 2 3GAA221210-··G 55 M3AA 250SMA 2 3GAA251210-··G 75 M3AA 280SMA 2 3GAA281210-··G 90 1) M3AA 280SMB 2 3GAA281220-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 3420 3400 3420 3505 3490 3510 3480 3530 3490 3515 3525 3547 3545 3543 3559 3562 3564 3566 3571 3568 3575 460 V 60 Hz 73.8 71.6 77.5 77.5 81.9 82.6 82.5 81.4 82.6 81.9 85.1 85.0 85.8 85.9 87.5 86.7 87.6 88.4 88.5 87.8 89.5 89.2 91.4 91.5 92.1 92.3 92.4 92.8 92.4 92.4 93.1 92.8 93.4 93.2 93.5 93.2 93.8 93.5 94.4 94.3 94.9 94.7 65.4 74.3 80.7 77.5 78.7 82.9 84.2 84.5 87.8 85.3 87.6 90.3 91.2 92.1 91.1 91.4 91.7 91.7 92.1 93.2 93.7 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.71 0.59 5.7 0.69 3.6 3.5 0.00017 0.71 0.84 5.9 1.03 3.2 3.5 0.00035 0.75 1.12 6.6 1.53 3.2 3.7 0.00045 0.80 1.43 9.6 2 3.7 4.5 0.0009 0.78 2.1 9.1 3 3.9 4.2 0.0012 0.84 2.6 8.4 4 2.8 3.8 0.0024 0.85 3.7 7.9 6 2.6 3.7 0.0027 0.84 5.1 10.0 8.1 4.1 4.6 0.005 0.91 6.2 8.1 10.9 2.7 3.0 0.0062 0.86 9 8.5 14.9 2.5 4.1 0.016 0.89 12 8.7 20.3 2.3 3.7 0.022 0.90 16.7 8.6 29.6 2.6 3.5 0.044 0.90 22.4 8.7 40.4 2.7 3.8 0.053 0.92 27.2 8.7 49.8 3.1 3.8 0.063 0.87 34.3 8.8 59 3.0 3.8 0.076 0.90 44.9 8.7 80.4 2.8 3.4 0.178 0.89 55.8 9.2 99.1 3.1 3.7 0.196 0.88 68.6 7.7 120 2.6 2.7 0.244 0.88 83.2 7.7 147 2.3 3.0 0.507 0.89 112 8.0 200 2.6 3.2 0.583 0.89 133 8.9 240 2.8 3.5 0.644 Weight kg Sound pressure Level LPA dB 4.2 4.9 61 5.9 61 10.5 63 11 63 16 63 18 66 25 65 30 71 52 76 52 76 91 73 105 73 123 73 132 73 210 76 225 76 263 78 304 79 389 79 425 79 1) Temperature rise class F Output kW Motor type Product code 3600 r/min = 2 poles 11 M3AA 132SMF 2 3GAA131260-··E 15 M3AA 132SMG 2 3GAA131270-··E 17.5 M3AA 132SMG 2 3GAA131270-··E 18.5 M3AA 132SMJ 2 3GAA131290-··E 21.5 M3AA 132SMJ 2 3GAA131290-··E 22 M3AA 160MLD 2 3GAA161440-··G 30 M3AA 160MLE 2 3GAA161450-··G 30 M3AA 180MLB 2 3GAA181420-··G 45 M3AA 200MLC 2 3GAA201430-··G 55 M3AA 200MLD 2 3GAA201440-··G 55 M3AA 225SMB 2 3GAA221220-··G 75 M3AA 225SMC 2 3GAA221230-··G 75 M3AA 250SMB 2 3GAA251220-··G 80 M3AA 225SMD 2 3GAA221240-··G 90 M3AA 250SMC 2 3GAA251230-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 3504 3510 3495 3500 3486 3546 3539 3558 3563 3560 3567 3573 3575 3570 3575 460 V 60 Hz 90.9 90.3 90.7 90.4 91.0 91.5 91.6 91.8 91.4 92.2 92.4 92.8 92.5 93.2 93.0 93.1 93.4 93.3 94.3 94.4 93.9 93.7 94.3 94.1 94.5 94.4 94.5 94.4 95.1 95.0 88.3 88.8 90.5 90.9 92.0 92.0 92.7 92.4 92.2 93.4 92.4 93.0 93.3 93.3 94.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.94 17.2 9.0 30 2.8 4.3 0.0187 0.89 23.6 9.5 40.7 3.5 4.6 0.02 0.90 27 8.9 47.8 2.8 3.8 0.02 0.91 28.2 10.5 50.3 3.3 5.3 0.0256 0.89 33.2 9.7 58.9 2.9 4.3 0.0256 0.91 32.8 9.3 59.2 3.4 4.1 0.063 0.91 44.6 9.1 80.9 3.3 3.9 0.072 0.89 45.4 9.2 80.5 3.1 3.8 0.092 0.88 68.7 9.2 120 3.2 3.7 0.196 0.89 82.2 9.0 147 3.1 3.7 0.217 0.89 82.6 7.5 147 2.5 2.8 0.274 0.86 116 8.7 200 3.3 3.4 0.309 0.89 111 8.6 200 2.9 3.4 0.583 0.88 120 8.4 213 3.1 3.2 0.329 0.89 133 8.6 240 2.7 3.4 0.644 Weight kg Sound pressure Level LPA dB 77 68 81 72 81 69 93 71 93 68 123 73 145 73 149 73 225 76 241 76 286 78 312 78 351 79 317 78 386 79 ABB Motors and Generators | 9AKK105944 EN 02-2020 111 Technical data, 460 V 60 Hz IE2 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1800 r/min = 4 poles 0.12 M3AA 63A 4 3GAA062311-··E 0.18 M3AA 63B 4 3GAA062312-··E 0.25 M3AA 71A 4 3GAA072311-··E 0.37 M3AA 71B 4 3GAA072312-··E 0.55 M3AA 80A 4 3GAA082311-··E 0.75 M3AA 80D 4 3GAA082314-··E 1.1 M3AA 90LB 4 3GAA092520-··E 1.5 M3AA 90LD 4 3GAA092540-··E 2.2 M3AA 100LC 4 3GAA102530-··E 3 M3AA 100LD 4 3GAA102540-··E 4 M3AA 112MB 4 3GAA112320-··E 5.5 M3AA 132M 4 3GAA132300-··E 7.5 M3AA 132MA 4 3GAA132310-··E 11 M3AA 160MLA 4 3GAA162410-··G 15 M3AA 160MLB 4 3GAA162420-··G 18.5 M3AA 180MLA 4 3GAA182410-··G 22 M3AA 180MLB 4 3GAA182420-··G 30 M3AA 200MLA 4 3GAA202410-··G 37 M3AA 225SMA 4 3GAA222210-··G 45 M3AA 225SMB 4 3GAA222220-··G 55 M3AA 250SMA 4 3GAA252210-··G 75 M3AA 280SMA 4 3GAA282210-··G 90 M3AA 280SMB 4 3GAA282220-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1690 1700 1685 1695 1695 1730 1740 1750 1760 1750 1745 1769 1764 1772 1775 1781 1780 1783 1782 1784 1782 1782 1782 460 V 60 Hz 57.9 53.6 66.6 63.3 69.3 68.7 74.4 74.9 77.7 78.7 82.6 82.5 84.6 83.7 85.4 84.1 87.5 86.9 88.2 87.5 87.6 87.5 89.7 89.6 89.5 89.6 91.3 91.6 92.2 92.4 92.5 92.8 93.1 93.4 93.8 94.0 93.6 93.5 94.2 94.1 95.2 95.4 94.7 94.8 94.9 95.0 45.3 55.8 64.0 71.9 76.6 79.8 80.7 80.6 84.2 85.6 85.7 87.9 88.3 90.5 91.5 91.9 92.5 93.1 92.5 93.1 94.9 94.1 94.3 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.56 0.46 3.6 0.68 2.9 3.3 0.00027 0.55 0.61 4.0 1 3.4 3.7 0.00034 0.68 0.66 4.8 1.41 2.3 2.7 0.00066 0.72 0.86 5.3 2 2.2 2.6 0.0008 0.74 1.2 5.5 3 2.0 2.8 0.0013 0.70 1.62 7.0 4.1 3.0 3.9 0.0016 0.76 2.1 7.6 6 3.1 3.9 0.0043 0.72 3 8.2 8.1 3.8 4.6 0.0048 0.75 4.2 9.1 11.9 3.4 4.5 0.009 0.80 5.3 8.2 16.3 3.6 4.2 0.011 0.77 7.4 8.2 21.8 3.3 3.7 0.0126 0.79 9.5 7.3 29.8 2.0 3.0 0.038 0.81 12.8 7.5 40.6 1.9 3.0 0.048 0.83 18.2 7.7 59.2 2.4 3.2 0.081 0.83 24.6 8.0 80.6 2.7 3.3 0.099 0.83 30.2 8.2 99.1 2.8 3.2 0.166 0.83 35.7 8.3 118 2.8 3.3 0.195 0.83 48.2 8.4 160 3.0 3.3 0.309 0.84 59 8.1 198 2.8 3.2 0.356 0.85 70.5 8.6 240 2.7 3.3 0.44 0.84 86.3 8.0 294 2.8 3.3 0.765 0.85 116 8.2 401 3.0 3.3 0.866 0.84 141 9.0 482 3.6 3.8 0.941 Weight kg Sound pressure Level LPA dB 3.7 4.2 5.2 48 5.9 48 8.5 53 10 53 16 53 17 53 25 57 28 66 34 67 48 69 59 66 99 66 118 66 146 66 163 66 218 67 240 70 273 70 314 71 389 71 418 71 Output kW Motor type Product code 1800 r/min = 4 poles 11 M3AA 132SMF 4 3GAA132260-··E 15 M3AA 132SMH 4 3GAA132280-··E 18.5 M3AA 160MLC 4 3GAA162430-··G 22 M3AA 160MLD 4 3GAA162440-··G 30 M3AA 180MLC 4 3GAA182430-··G 37 M3AA 200MLB 4 3GAA202420-··G 45 M3AA 200MLC 4 3GAA202430-··G 55 M3AA 225SMC 4 3GAA222230-··G 64 M3AA 225SMD 4 3GAA222240-··G 75 M3AA 250SMB 4 3GAA252220-··G 90 M3AA 250SMC 4 3GAA252230-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1765 1760 1774 1770 1777 1783 1783 1782 1783 1782 1776 460 V 60 Hz 91.5 91.2 91.7 91.5 92.4 92.7 92.5 93.2 93.2 93.6 94.2 94.6 94.4 94.5 94.4 94.6 94.4 94.4 94.8 95.0 95.2 95.3 89.6 90.2 92.0 92.6 93.0 94.1 93.9 93.8 93.4 94.4 94.6 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.80 18.7 8.8 59.5 2.2 3.5 0.0433 0.78 26 8.2 81.54 2.6 3.4 0.0517 0.83 30.2 8.7 99.5 3.3 3.6 0.11 0.84 35.4 7.8 118 2.7 3.3 0.125 0.83 48.6 8.3 161 2.9 3.3 0.217 0.84 58.6 8.5 198 2.8 3.3 0.343 0.83 72 8.6 241 3.2 3.6 0.366 0.85 86 8.5 294 3.1 3.4 0.474 0.85 100 9.4 342 3.5 3.7 0.542 0.85 116 8.4 401 3.1 3.5 0.866 0.84 141 8.6 483 3.5 3.7 0.941 Weight kg Sound pressure Level LPA dB 83 68 82 70 127 66 140 66 177 66 234 67 246 67 287 70 314 70 350 71 377 71 112 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 460 V 60 Hz IE2 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1200 r/min = 6 poles 0.09 M3AA 63A 6 3GAA063311-··E 0.12 M3AA 63B 6 3GAA063312-··E 0.18 M3AA 71A 6 3GAA073311-··E 0.25 M3AA 71B 6 3GAA073312-··E 0.37 M3AA 80A 6 3GAA083311-··E 0.55 M3AA 80B 6 3GAA083312-··E 0.75 M3AA 90LB 6 3GAA093520-··E 1.1 M3AA 90LD 6 3GAA093540-··E 1.5 M3AA 100LC 6 3GAA103530-··E 2.2 M3AA 112MB 6 3GAA113320-··E 3 M3AA 132S 6 3GAA133100-··E 4 M3AA 132MB 6 3GAA133320-··E 5.5 M3AA 132MC 6 3GAA133330-··E 7.5 M3AA 160MLA 6 3GAA163410-··G 11 M3AA 160MLB 6 3GAA163420-··G 15 M3AA 180MLA 6 3GAA183410-··G 18.5 M3AA 200MLA 6 3GAA203410-··G 22 M3AA 200MLB 6 3GAA203420-··G 30 M3AA 225SMA 6 3GAA223210-··G 37 M3AA 250SMA 6 3GAA253210-··G 45 M3AA 280SMA 6 3GAA283210-··G 55 M3AA 280SMB 6 3GAA283220-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1110 1110 1110 1110 1125 1120 1140 1141 1150 1160 1161 1177 1165 1179 1177 1181 1190 1189 1189 1191 1190 1190 460 V 60 Hz 53.4 48.9 55.1 50.6 65.3 64.1 68.8 67.2 73.4 73.5 74.6 75.0 79.6 79.2 80.3 80.0 83.3 83.3 84.4 83.8 85.4 84.3 87.3 86.1 87.6 86.5 89.6 90.1 90.4 91.0 91.6 91.9 92.2 92.2 92.7 93.1 93.2 93.4 93.6 93.8 93.8 94.2 94.0 94.3 40.6 42.2 58.4 61.5 69.8 71.7 75.4 77.1 81.4 80.6 81.0 82.9 83.4 88.9 90.0 91.1 91.1 92.2 92.4 93.1 93.6 93.7 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.55 0.38 3.2 0.76 2.4 2.6 0.00042 0.53 0.51 3.4 1.02 2.6 3.0 0.00052 0.64 0.54 3.8 1.54 2.1 2.5 0.00092 0.61 0.74 4.1 2.1 2.7 3.0 0.0012 0.69 0.91 4.3 3.1 1.8 2.6 0.002 0.68 1.36 4.0 4.6 1.8 2.4 0.0026 0.67 1.71 4.5 6.2 2.1 2.7 0.0048 0.64 2.6 5.0 9.1 2.4 3.1 0.0056 0.70 3.2 4.4 12.4 1.8 2.4 0.009 0.65 5 5.9 18.1 2.5 3.3 0.01 0.67 6.84 4.7 24.3 1.7 2.8 0.031 0.69 8.3 8.0 32.4 2.2 5.1 0.045 0.67 11.8 6.8 44.96 2.7 3.2 0.049 0.77 13.6 7.4 60.7 1.7 3.2 0.087 0.77 19.8 8.4 89.2 2.0 3.4 0.114 0.75 27.4 6.5 121 1.9 3.1 0.168 0.79 31.8 7.5 148 2.5 3.2 0.382 0.81 36.7 7.5 176 2.5 3.2 0.448 0.82 49.2 8.0 240 2.8 3.2 0.663 0.81 61.2 7.6 296 2.6 3.0 1.13 0.83 72.5 7.6 361 2.6 2.9 1.37 0.83 88.4 8.1 441 2.9 3.1 1.5 Weight kg Sound pressure Level LPA dB 4.2 4.5 5.5 42 6.5 42 9 47 10 47 18 44 20 47 26 49 34 56 46 60 54 60 59 64 98 63 125 63 148 63 196 67 218 67 266 67 294 67 378 67 404 67 Output kW Motor type Product code 1200 r/min = 6 poles 15 M3AA 160MLC 6 3GAA163430-··G 18.5 M3AA 180MLB 6 3GAA183420-··G 30 M3AA 200MLC 6 3GAA203430-··G 37 M3AA 225SMB 6 3GAA223220-··G 45 M3AA 225SMC 6 3GAA223230-··G 45 M3AA 250SMB 6 3GAA253220-··G 55 M3AA 250SMC 6 3GAA253230-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1176 1180 1188 1188 1187 1191 1189 460 V 60 Hz 90.7 91.3 92.0 92.5 93.0 93.3 93.8 94.1 93.6 94.1 93.9 94.2 94.0 94.3 90.5 91.8 92.5 93.5 93.6 93.5 93.7 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.75 27.6 8.1 121 1.9 4.1 0.131 0.78 32.3 6.6 149 1.9 3.0 0.198 0.83 48.7 8.0 241 2.6 3.2 0.531 0.83 59.6 7.5 297 2.5 3.0 0.821 0.82 73.5 7.3 362 2.5 2.9 0.821 0.82 73.3 7.9 360 2.7 3.1 1.37 0.83 88.4 8.1 441 2.9 3.1 1.5 Weight kg Sound pressure Level LPA dB 138 63 162 63 245 67 300 67 300 67 341 67 367 67 ABB Motors and Generators | 9AKK105944 EN 02-2020 113 Technical data, 460 V 60 Hz IE2 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 900 r/min = 8 poles 0.055 M3AA 63B 8 3GAA064002-··E 0.09 M3AA 71A 8 3GAA074001-··E 0.12 M3AA 71B 8 3GAA074002-··E 0.18 M3AA 80A 8 3GAA084001-··E 0.25 M3AA 80B 8 3GAA084002-··E 0.37 M3AA 90S 8 3GAA094100-··E 0.55 M3AA 90L 8 3GAA094500-··E 0.75 M3AA 100LA 8 3GAA104510-··E 1.1 M3AA 100LB 8 3GAA104520-··E 1.5 M3AA 112M 8 3GAA114300-··E 2.2 M3AA 132S 8 3GAA134100-··E 3 M3AA 132M 8 3GAA134300-··E 4 M3AA 160MLA 8 3GAA164410-··G 5.5 M3AA 160MLB 8 3GAA164420-··G 7.5 M3AA 160MLC 8 3GAA164430-··G 11 M3AA 180MLA 8 3GAA184410-··G 15 M3AA 200MLA 8 3GAA204410-··G 18.5 M3AA 225SMA 8 3GAA224210-··G 22 M3AA 225SMB 8 3GAA224220-··G 30 M3AA 250SMA 8 3GAA254210-··G 37 M3AA 280SMA 8 3GAA284210-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 460 V 60 Hz 850 36.9 31.7 840 50.8 46.2 830 54.3 50.3 850 59.5 56.2 850 63.5 60.7 851 62.9 58.7 811 65.5 62.5 865 74.2 71.3 860 77.4 75.9 855 78.6 77.4 870 79.0 78.2 865 81.0 81.8 882 85.8 85.7 881 86.4 86.6 882 87.7 87.9 885 88.6 89.2 890 91.5 91.8 890 92.1 92.3 890 92.4 92.6 893 93.0 93.0 892 93.1 93.2 24.3 38.3 42.6 49.0 53.9 50.4 55.5 64.6 71.0 73.1 74.9 79.8 83.4 84.6 86.3 87.8 90.8 91.2 91.6 91.9 92.3 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.42 0.45 2.0 0.62 2.7 3.2 0.00045 0.50 0.44 2.9 1.02 2.7 2.7 0.00092 0.52 0.53 2.9 1.38 2.7 2.8 0.0012 0.55 0.69 3.3 2 2.6 2.9 0.0018 0.54 0.91 3.6 2.8 2.8 3.1 0.0024 0.48 1.56 3.0 4.1 1.9 2.7 0.0032 0.49 2.15 2.8 6.1 1.6 2.1 0.0043 0.51 2.4 4.2 8.2 2.6 3.4 0.0069 0.57 3.1 4.0 12.2 2.2 2.9 0.0082 0.61 3.9 4.2 16.7 2.1 2.8 0.01 0.64 5.4 4.1 24.1 1.4 2.4 0.031 0.68 6.8 3.2 33.1 1.2 2.0 0.037 0.64 9.1 5.9 43.3 1.6 3.0 0.068 0.65 12.2 6.2 59.6 1.5 3.0 0.085 0.63 17 5.1 81.2 1.5 3.2 0.132 0.66 23.5 5.1 118 2.0 2.9 0.214 0.71 28.5 5.9 160 2.3 2.7 0.45 0.72 35 5.9 198 2.2 2.5 0.669 0.73 40.8 6.3 236 2.2 2.6 0.722 0.70 57.8 6.6 320 2.8 2.7 1.4 0.73 68.3 6.4 396 2.6 2.6 1.51 Weight kg Sound pressure Level LPA dB 5.3 5.5 40 6.5 43 8.5 45 9.5 50 13 55 16 55 20 46 23 53 28 55 46 59 53 61 84 63 98 63 137 63 175 63 217 64 266 67 279 67 340 67 403 67 Output kW Motor type Product code 900 r/min = 8 poles 0.18 M3AA 71C 8 3GAA074003-··E 0.37 M3AA 80C 8 3GAA084003-··E 0.75 M3AA 90LF 8 3GAA094560-··E 1.5 M3AA 100LG 8 3GAA104570-··E 2 M3AA 112MF 8 3GAA114360-··E 4.4 1) M3AA 132MF 8 3GAA134360-··E 18.5 M3AA 200MLB 8 3GAA204420-··G 30 M3AA 225SMC 8 3GAA224230-··G 37 M3AA 250SMB 8 3GAA254220-··G 45 M3AA 250SMC 8 3GAA254230-··G Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 460 V 60 Hz 830 53.5 50.1 845 65.8 64.0 810 66.1 63.5 845 76.6 75.6 850 79.1 79.1 860 80.0 82.1 891 91.2 91.4 889 92.8 93.1 891 93.6 93.9 891 93.4 93.9 42.4 57.8 57.1 71.7 75.7 80.9 90.2 92.4 93.3 93.4 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.56 0.75 3.1 2 2.5 2.6 0.0015 0.57 1.23 3.7 4.1 2.6 2.8 0.0031 0.52 2.9 3.0 8.8 2.0 2.5 0.0048 0.60 4 3.7 16.9 2.1 2.5 0.009 0.63 5 4.0 22.4 1.9 2.6 0.0126 0.69 10 3.8 48.8 1.3 2.6 0.049 0.72 35.3 6.1 198 2.3 2.6 0.53 0.72 56.3 6.4 322 2.6 2.7 0.828 0.72 68.9 6.1 396 2.8 2.6 1.51 0.74 81.7 6.4 482 2.5 2.7 1.51 Weight kg Sound pressure Level LPA dB 7 42 11 47 18 46 26 49 32 60 54 71 245 64 300 67 367 67 367 67 1) Temperature rise class F 114 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE3 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3000 r/min = 2 poles 0.75 M3AA 80B 2 3GAA081612-··J 1.1 M3AA 80C 2 3GAA081613-··J 1.1 M3AA 80C 2 3GAA081613-··J 1.5 M3AA 90L 2 3GAA091500-··J 2.2 M3AA 90LB 2 3GAA091520-··J 3 M3AA 100LB 2 3GAA101520-··J 4 M3AA 112MB 2 3GAA111320-··J 5.5 M3AA 132SB 2 3GAA131120-··J 7.5 M3AA 132SC 2 3GAA131130-··J 22 M3AA 180MLA 2 3GAA181410-··L 30 M3AA 200MLA 2 3GAA201410-··L 37 M3AA 200MLB 2 3GAA201420-··L 45 M3AA 225SMA 2 3GAA221210-··L 55 M3AA 250SMA 2 3GAA251210-··L 75 M3AA 280SMA 2 3GAA281210-··L 90 1) M3AA 280SMB 2 3GAA281220-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 2885 2871 2871 2906 2903 2896 2888 2901 2909 2944 2957 2952 2955 2966 2971 2968 400 V 50 Hz 80.7 80.9 82.7 82.8 82.7 82.8 84.2 84.7 85.9 86.3 87.1 88.2 88.1 89.4 89.2 89.9 90.1 91.3 92.7 93.5 93.3 94.0 93.7 94.5 94.0 94.5 94.3 94.6 94.7 95.1 95.0 95.4 80.2 80.7 80.7 84.6 84.9 88.0 89.6 90.1 91.5 93.4 93.9 94.5 94.4 94.1 94.8 95.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.76 1.7 7.5 2.5 4.1 4.6 0.002 0.80 2.4 7.6 3.66 4.0 4.2 0.002 0.80 2.4 7.6 3.66 4.0 4.2 0.002 0.89 2.8 7.9 4.9 2.3 3.3 0.0027 0.79 4.7 7.4 7.2 3.2 3.8 0.003 0.90 5.4 8.4 9.8 3.2 3.9 0.0057 0.91 7.1 8.4 13.2 3.2 4.0 0.0104 0.91 9.7 7.9 18.1 2.3 3.4 0.0154 0.90 13.1 8.3 24.6 3.0 3.9 0.0173 0.90 38 8.4 71.4 3.2 3.7 0.071 0.88 52.7 8.7 96.9 3.0 3.8 0.104 0.88 64.7 8.7 120 3.1 3.7 0.115 0.89 77.6 8.0 145 2.9 3.3 0.214 0.88 95.6 7.4 177 2.9 2.9 0.274 0.90 127 7.9 241 2.8 3.3 0.644 0.90 151 8.4 290 2.7 3.4 0.644 Weight kg Sound pressure Level LPA dB 9.4 60 11 60 11 60 16 60 18 63 31 62 35 68 56 68 63 70 133 74 171 74 185 74 254 77 302 79 413 81 421 81 1) Temperature rise class F Output kW Motor type Product code 1500 r/min = 4 poles 0.75 M3AA 80ME 4 3GAA082614-··J 1.1 M3AA 90LB 4 3GAA092520-··J 1.5 M3AA 90LD 4 3GAA092540-··J 2.2 M3AA 100LC 4 3GAA102530-··J 3 M3AA 100LD 4 3GAA102540-··J 4 M3AA 112MB 4 3GAA112320-··J 5.5 M3AA 132M 4 3GAA132300-··J 7.5 M3AA 132MA 4 3GAA132310-··J 18.5 M3AA 180MLA 4 3GAA182410-··L 30 M3AA 200MLA 4 3GAA202410-··L 37 M3AA 225SMA 4 3GAA222210-··L 55 M3AA 250SMA 4 3GAA252210-··L 75 M3AA 280SMA 4 3GAA282210-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1424 1437 1445 1455 1445 1451 1460 1462 1473 1476 1480 1478 1482 400 V 50 Hz 82.5 83.2 84.1 83.7 85.3 85.0 86.7 86.6 87.9 88.4 88.6 89.4 89.6 90.1 90.6 91.1 92.6 93.3 93.6 94.1 93.9 94.8 94.6 94.9 95.0 95.5 81.8 81.2 82.7 84.6 87.8 89.0 89.6 90.5 93.1 94.1 94.8 94.8 95.3 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.76 1.74 6.1 5 2.5 3.4 0.0016 0.78 2.46 8.0 7.32 3.3 3.8 0.007 0.75 3.34 7.6 9.95 3.4 4.1 0.007 0.80 4.6 7.9 14.4 3.2 4.0 0.011 0.83 5.9 7.7 19.8 2.8 3.5 0.014 0.77 8.6 7.6 26.3 3.1 4.1 0.018 0.82 11 6.6 35.9 2.2 3.3 0.031 0.79 15.6 6.7 48.9 2.5 3.4 0.037 0.82 35.1 8.3 120 3.1 3.5 0.124 0.82 56.5 7.4 195 2.5 3.2 0.191 0.82 69.3 7.5 239 2.8 2.9 0.362 0.84 99.9 7.7 355 3.3 3.3 0.536 0.82 138 7.9 483 3.6 3.8 0.941 Weight kg Sound pressure Level LPA dB 13.1 54 17 50 20 50 25 54 32 63 34 64 48 66 59 63 137 67 193 62 249 68 331 71 410 73 ABB Motors and Generators | 9AKK105944 EN 02-2020 115 Technical data, 400 V 50 Hz IE3 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1000 r/min = 6 poles 0.75 M3AA 90LB 6 3GAA093520-··J 1.1 M3AA 90LD 6 3GAA093540-··J 1.5 M3AA 100LC 6 3GAA103530-··J 2.2 M3AA 112MB 6 3GAA113320-··J 3 M3AA 132S 6 3GAA133100-··J 4 M3AA 132MA 6 3GAA133310-··J 5.5 M3AA 132MC 6 3GAA133330-··J 18.5 M3AA 200MLA 6 3GAA203410-··L 37 M3AA 250SMA 6 3GAA253210-··L 45 M3AA 280SMA 6 3GAA283210-··L 55 M3AA 280SMB 6 3GAA283220-··L Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 930 78.9 78.9 76.7 928 81.0 81.7 81.2 962 84.7 85.0 83.3 957 84.3 85.0 84.0 972 85.6 85.5 83.6 964 86.8 88.0 87.8 970 88.5 89.4 88.8 980 91.7 92.5 92.0 985 93.3 93.7 93.4 991 93.7 94.1 93.6 989 94.1 94.7 94.4 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.68 2.08 3.9 7.7 2.3 2.7 0.007 0.77 2.71 4.0 11.3 1.7 2.2 0.007 0.69 3.6 5.3 14.9 2.5 3.1 0.014 0.65 5.9 5.3 21.9 2.3 3.0 0.018 0.69 7.4 5.3 29.5 1.8 3.0 0.031 0.75 8.9 4.5 39.1 1.8 3.0 0.039 0.67 13.3 6.1 54.2 2.3 3.1 0.044 0.75 38.8 6.4 180 2.1 3.1 0.22 0.80 71.5 7.0 359 2.7 3.0 0.813 0.81 85.5 7.6 434 2.9 3.3 1.5 0.80 105 7.1 531 3.0 3.1 1.49 Weight kg Sound pressure Level LPA dB 17 44 19 44 28 49 33 56 48 57 60 61 64 61 177 65 320 68 399 68 400 68 116 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE3 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3000 r/min = 2 poles 0.75 M3AA 80MB 2 3GAA081320-··K 1.1 M3AA 80MC 2 3GAA081330-··K 1.5 M3AA 90LB 2 3GAA091520-··K 2.2 M3AA 90LC 2 3GAA091530-··K 3 M3AA 100LC 2 3GAA101530-··K 4 M3AA 112MB 2 3GAA111320-··K 5.5 M3AA 132SB 2 3GAA131120-··K 7.5 M3AA 132SC 2 3GAA131130-··K 11 M3AA 160MLA 2 3GAA161410-··K 15 M3AA 160MLB 2 3GAA161420-··K 18.5 M3AA 160MLC 2 3GAA161430-··K 22 M3AA 180MLA 2 3GAA181410-··K 30 M3AA 200MLA 2 3GAA201410-··K 37 M3AA 200MLB 2 3GAA201420-··K 45 M3AA 225SMA 2 3GAA221210-··K 55 M3AA 250SMA 2 3GAA251210-··K 75 1) M3AA 280SMA 2 3GAA281210-··K 90 1) M3AA 280SMB 2 3GAA281220-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 2894 2883 2906 2900 2896 2888 2901 2909 2943 2947 2949 2956 2958 2961 2968 2968 2971 2968 400 V 50 Hz 83.1 82.8 83.9 83.6 86.1 86.6 87.4 88.8 87.9 88.9 88.5 89.8 89.3 90.0 90.7 91.8 91.2 92.0 91.9 92.2 92.4 93.0 92.7 93.1 93.3 93.7 93.7 94.1 94.0 94.0 94.3 93.7 94.7 95.1 95.0 95.4 80.0 82.0 86.5 88.9 88.7 90.0 90.2 92.0 91.6 91.8 92.6 92.7 93.4 93.8 93.0 93.6 94.8 95.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.74 1.74 7.9 2.4 3.7 4.2 0.0008 0.81 2.3 7.9 3.6 3.7 4.2 0.001 0.89 2.8 7.9 4.9 2.3 3.3 0.0027 0.89 4 8.3 7.2 2.9 3.5 0.0032 0.90 5.4 8.4 9.8 3.2 3.9 0.0057 0.91 7.1 8.4 13.2 3.2 4.0 0.0104 0.91 9.7 7.9 18.1 2.3 3.4 0.0154 0.90 13.1 8.3 24.6 3.0 3.9 0.0173 0.91 19.1 7.2 35.57 2.6 3.6 0.057 0.88 26.7 8.2 48.6 3.2 4.2 0.063 0.90 32.1 9.0 59.9 3.3 3.9 0.076 0.90 37.7 7.8 71.0 3.4 3.8 0.11 0.89 52 7.7 96.8 2.7 3.1 0.178 0.88 64.4 8.2 119 3.0 3.3 0.196 0.87 79.6 7.3 145 3.2 3.1 0.296 0.89 94.8 6.8 177 2.4 3.0 0.426 0.90 127 7.9 241 2.8 3.3 0.644 0.90 151 8.4 290 2.7 3.4 0.644 Weight kg Sound pressure Level LPA dB 9.5 57 10.5 56 17 60 20 60 28 62 38 68 58 68 63 70 106 69 123 69 137 73 176 73 225 72 241 72 326 76 351 76 412 81 420 81 1) Temperature rise class F Output kW Motor type Product code 3000 r/min = 2 poles 22 M3AA 160MLD 2 3GAA161440-··K 30 M3AA 180MLB 2 3GAA181420-··K 37 1) M3AA 180MLC 2 3GAA181430-··K 45 M3AA 200MLC 2 3GAA201430-··K 55 M3AA 225SMB 2 3GAA221220-··K 75 1) M3AA 225SMC 2 3GAA221230-··K 75 1) M3AA 250SMB 2 3GAA251220-··K 90 1) M3AA 250SMC 2 3GAA251230-··K 1) Temperature rise class F Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 2944 2957 2952 2955 2966 2966 2971 2968 400 V 50 Hz 92.7 93.5 93.3 94.0 93.7 94.5 94.0 94.6 94.3 94.6 94.7 94.8 94.7 95.1 95.0 95.4 93.4 93.9 94.5 94.5 94.1 94.1 94.8 95.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.90 38 8.4 71.4 3.2 3.7 0.071 0.88 52.7 8.7 96.9 3.0 3.8 0.104 0.88 64.7 8.7 120 3.1 3.7 0.115 0.89 77.6 8.0 145 2.9 3.3 0.214 0.88 95.6 7.4 177 2.9 2.9 0.274 0.88 129 8.1 241 3.3 3.0 0.329 0.90 127 7.9 241 2.8 3.3 0.644 0.90 151 8.4 290 2.7 3.4 0.644 Weight kg Sound pressure Level LPA dB 131 74 162 74 176 74 250 77 288 79 328 79 405 81 414 81 ABB Motors and Generators | 9AKK105944 EN 02-2020 117 Technical data, 400 V 50 Hz IE3 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1500 r/min = 4 poles 0.75 M3AA 80ME 4 3GAA082350-··K 1.1 M3AA 90LC 4 3GAA092530-··K 1.5 M3AA 90LD 4 3GAA092540-··K 2.2 M3AA 100LE 4 3GAA102550-··K 3 M3AA 100LF 4 3GAA102560-··K 4 M3AA 112MB 4 3GAA112320-··K 5.5 M3AA 132MB 4 3GAA132320-··K 7.5 M3AA 132MC 4 3GAA132330-··K 11 M3AA 160MLA 4 3GAA162410-··K 15 M3AA 160MLB 4 3GAA162420-··K 18.5 M3AA 180MLA 4 3GAA182410-··K 22 M3AA 180MLB 4 3GAA182420-··K 30 M3AA 200MLA 4 3GAA202410-··K 37 M3AA 225SMA 4 3GAA222210-··K 45 M3AA 225SMB 4 3GAA222220-··K 55 M3AA 250SMA 4 3GAA252210-··K 75 M3AA 280SMA 4 3GAA282210-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1440 1442 1439 1454 1452 1454 1464 1464 1477 1474 1481 1480 1481 1482 1482 1485 1482 400 V 50 Hz 84.0 83.9 85.6 85.1 85.3 84.7 89.1 89.5 88.8 89.2 88.6 89.1 89.6 90.2 90.6 91.0 91.4 91.8 92.1 92.2 92.6 93.2 93.3 94.1 93.6 93.9 93.9 94.1 94.2 94.4 95.4 95.9 95.0 95.5 81.9 83.4 82.8 88.6 88.3 88.6 89.5 90.9 91.1 91.3 92.9 94.1 93.4 93.8 94.0 95.7 95.3 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.76 1.68 7.9 4.9 3.3 3.7 0.0027 0.80 2.3 7.9 7.2 3.3 3.9 0.0055 0.78 3.2 8.2 9.9 3.5 4.0 0.0055 0.83 4.3 8.9 14.5 3.1 4.1 0.0144 0.83 5.9 9.0 19.7 3.5 4.2 0.0144 0.75 8.7 7.5 26.3 3.5 3.7 0.0176 0.78 11.4 7.0 35.9 2.8 3.9 0.0295 0.81 14.7 7.7 48.9 2.5 3.6 0.0414 0.82 21.1 7.6 71.3 2.6 3.3 0.11 0.81 29 7.8 97.2 3.0 3.7 0.135 0.83 34.9 7.2 119 2.8 3.0 0.219 0.82 41.5 8.2 141 2.8 3.1 0.217 0.84 55.1 7.5 193 2.7 3.2 0.385 0.83 68.9 7.2 239 3.1 3.1 0.427 0.84 82.3 8.0 290 3.2 3.5 0.525 0.85 97.8 7.9 353 3.0 3.3 0.933 0.82 138 7.9 483 3.6 3.8 0.941 Weight kg Sound pressure Level LPA dB 13.5 54 19 56 19 51 36 54 36 54 44 59 68 70 68 64 126 61 140 61 177 60 176 62 246 63 315 67 316 66 376 67 409 73 Output kW Motor type Product code 1500 r/min = 4 poles 18.5 M3AA 160MLC 4 3GAA162430-··K 30 M3AA 180MLC 4 3GAA182430-··K 37 1) M3AA 200MLB 4 3GAA202420-··K 55 M3AA 225SMC 4 3GAA222230-··K 75 M3AA 250SMB 4 3GAA252220-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1473 1476 1480 1478 1482 400 V 50 Hz 92.6 93.4 93.6 94.2 93.9 94.8 94.6 94.9 95.0 95.4 93.1 94.2 94.8 94.8 95.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.82 35.1 8.3 120 3.1 3.5 0.124 0.82 56.5 7.4 195 2.5 3.2 0.191 0.82 69.3 7.5 239 2.8 2.9 0.362 0.84 99.9 7.7 355 3.3 3.3 0.536 0.84 135 7.9 483 3.3 3.5 0.941 Weight kg Sound pressure Level LPA dB 135 67 176 62 244 68 318 71 389 73 1) Temperature rise class F 118 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 400 V 50 Hz IE3 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1000 r/min = 6 poles 0.75 M3AA 90LD 6 3GAA093540-··K 1.1 M3AA 100LE 6 3GAA103550-··K 1.5 M3AA 100LF 6 3GAA103560-··K 2.2 M3AA 112MC 6 3GAA113330-··K 3 M3AA 132MC 6 3GAA133330-··K 4 M3AA 132MD 6 3GAA133340-··K 5.5 M3AA 132ME 6 3GAA133350-··K 7.5 M3AA 160MLA 6 3GAA163410-··K 11 M3AA 160MLB 6 3GAA163420-··K 15 M3AA 180MLA 6 3GAA183410-··K 18.5 M3AA 200MLA 6 3GAA203410-··K 22 M3AA 200MLB 6 3GAA203420-··K 30 M3AA 225SMA 6 3GAA223210-··K 37 M3AA 250SMA 6 3GAA253210-··K 45 M3AA 280SMA 6 3GAA283210-··K 55 M3AA 280SMB 6 3GAA283220-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 937 80.3 80.5 79.5 963 84.0 85.0 84.0 969 85.7 85.9 84.2 967 87.2 87.9 87.1 978 88.5 88.8 87.7 973 88.5 89.3 89.1 973 89.5 90.2 89.6 980 90.8 91.5 91.0 979 91.2 91.8 91.1 987 92.2 92.5 91.5 990 92.8 93.2 92.6 990 93.3 93.7 93.1 989 94.1 94.7 94.5 991 94.4 94.9 94.7 991 93.7 94.1 93.6 989 94.1 94.8 94.5 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.76 1.78 4.6 7.6 2.1 2.3 0.0055 0.69 2.6 5.6 10.9 2.3 3.1 0.0138 0.65 3.7 7.0 14.7 3.3 4.1 0.0138 0.69 5.2 6.5 21.7 2.4 3.5 0.0187 0.69 7 6.2 29.2 2.0 3.0 0.0402 0.72 9.1 5.6 39.2 1.9 2.7 0.0402 0.74 12 5.8 53.9 2.0 2.9 0.039 0.78 15.2 7.9 73 1.7 3.3 0.114 0.74 23.5 8.5 107 2.2 3.9 0.131 0.77 30.4 5.5 146 1.7 2.7 0.225 0.77 37.3 7.5 178 2.6 3.2 0.448 0.79 43 7.8 212 2.6 3.2 0.531 0.81 56.8 7.9 289 2.8 3.1 0.813 0.83 68 7.7 356 2.7 2.9 1.49 0.81 85.5 7.6 434 2.9 3.3 1.5 0.80 105 7.1 531 3.0 3.1 1.49 Weight kg Sound pressure Level LPA dB 19 55 35 49 35 49 43 68 66 61 67 61 63 61 125 59 139 59 175 59 218 63 245 63 310 63 367 63 398 68 399 68 Output kW Motor type Product code 1000 r/min = 6 poles 18.5 M3AA 180MLB 6 3GAA183420-··K 37 M3AA 225SMB 6 3GAA223220-··K 45 M3AA 250SMB 6 3GAA253220-··K 55 M3AA 250SMC 6 3GAA253230-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 400 V 50 Hz 980 91.7 92.5 92.0 985 93.3 93.8 93.5 991 93.7 94.1 93.6 989 94.1 94.8 94.6 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.75 38.8 6.4 180 2.1 3.1 0.22 0.80 71.5 7.0 359 2.7 3.0 0.813 0.81 85.5 7.6 434 2.9 3.3 1.5 0.80 105 7.1 531 3.0 3.1 1.49 Weight kg Sound pressure Level LPA dB 168 65 307 68 389 68 390 68 ABB Motors and Generators | 9AKK105944 EN 02-2020 119 Technical data, 460V 60Hz IE3 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 3600 r/min = 2 poles 0.75 M3AA 80MB 2 3GAA081320-··K 1.1 M3AA 80MC 2 3GAA081330-··K 1.5 M3AA 90LB 2 3GAA091520-··K 2.2 M3AA 90LC 2 3GAA091530-··K 3 M3AA 100LC 2 3GAA101530-··K 4 M3AA 112MB 2 3GAA111320-··K 5.5 M3AA 132SB 2 3GAA131120-··K 7.5 M3AA 132SC 2 3GAA131130-··K 11 M3AA 160MLA 2 3GAA161410-··K 15 M3AA 160MLB 2 3GAA161420-··K 18.5 M3AA 160MLC 2 3GAA161430-··K 22 M3AA 180MLA 2 3GAA181410-··K 30 M3AA 200MLA 2 3GAA201410-··K 37 M3AA 200MLB 2 3GAA201420-··K 45 M3AA 225SMA 2 3GAA221210-··K 55 M3AA 250SMA 2 3GAA251210-··K 90 M3AA 280SMB 2 3GAA281220-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 3502 3500 3522 3517 3512 3500 3519 3524 3549 3554 3555 3560 3562 3564 3570 3569 3573 460 V 60 Hz 77.0 75.1 84.0 83.0 85.5 85.3 86.5 87.1 88.5 88.7 88.5 88.9 89.5 89.4 90.2 90.7 91.0 91.1 91.0 90.4 91.7 91.9 91.7 91.7 92.4 92.1 93.0 92.8 93.6 93.1 93.6 93.1 95.0 95.0 69.9 80.2 84.0 85.8 87.2 87.9 88.7 90.0 89.9 89.6 90.7 90.4 90.5 91.2 91.5 91.6 94.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.72 1.56 8.9 2 4.3 5.2 0.0008 0.78 2 9.9 3 4.4 5.3 0.001 0.88 2.4 9.6 4 2.5 4.0 0.0027 0.88 3.5 9.9 5.9 3.2 4.2 0.0032 0.89 4.7 9.9 8.1 3.5 4.6 0.0057 0.90 6.2 10.0 10.9 3.6 4.8 0.0104 0.90 8.4 9.1 14.9 2.5 3.9 0.0154 0.90 11.4 9.6 20.3 3.1 4.5 0.0173 0.91 16.6 8.7 29.5 2.7 3.9 0.057 0.89 23.2 8.5 40.3 3.8 4.8 0.063 0.89 28.4 10.5 49.7 3.8 4.7 0.076 0.89 33 9.2 59.0 4.1 4.7 0.11 0.89 45.8 8.7 80.4 2.8 3.4 0.178 0.88 56.7 9.2 99.1 3.1 3.7 0.196 0.89 67.4 7.8 120 3.3 3.7 0.296 0.90 82.7 7.9 147 2.3 3.3 0.426 0.90 132 9.5 241 2.8 3.7 0.644 Weight kg Sound pressure Level LPA dB 9.5 61 10.5 60 17 65 20 65 28 65 38 71 58 74 63 73 106 75 123 74 137 75 176 77 225 76 241 76 326 79 351 81 420 85 Output kW Motor type Product code 3600 r/min = 2 poles 22 M3AA 160MLD 2 3GAA161440-··K 30 M3AA 180MLB 2 3GAA181420-··K 37 M3AA 180MLC 2 3GAA181430-··K 45 M3AA 200MLC 2 3GAA201430-··K 55 M3AA 225SMB 2 3GAA221220-··K 75 M3AA 225SMC 2 3GAA221230-··K 75 M3AA 250SMB 2 3GAA251220-··K 90 M3AA 250SMC 2 3GAA251230-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 3552 3563 3560 3562 3571 3571 3575 3573 460 V 60 Hz 92.9 93.2 93.3 93.5 93.9 94.2 94.4 94.8 94.4 94.3 94.9 94.8 94.9 94.9 95.0 95.0 92.5 92.9 93.6 94.3 93.2 93.9 94.1 94.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.90 32.9 9.7 59.2 3.5 4.2 0.071 0.88 45.7 10.0 80.4 3.3 4.3 0.104 0.88 56.1 10.0 99.3 3.4 4.2 0.115 0.89 67.2 9.1 121 3.1 3.7 0.214 0.89 82.1 8.5 147 3.0 3.2 0.274 0.89 111 9.3 201 3.4 3.4 0.329 0.90 110 9.0 200 3.0 3.6 0.644 0.90 132 9.5 241 2.8 3.7 0.644 Weight kg Sound pressure Level LPA dB 131 78 162 78 176 78 250 81 288 83 328 83 405 85 414 85 120 9AKK105944 EN 02-2020 | ABB Motors and Generators Technical data, 460V 60Hz IE3 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1800 r/min = 4 poles 0.75 M3AA 80ME 4 3GAA082350-··K 1.1 M3AA 90LC 4 3GAA092530-··K 1.5 M3AA 90LD 4 3GAA092540-··K 2.2 M3AA 100LE 4 3GAA102550-··K 3 M3AA 100LF 4 3GAA102560-··K 4 M3AA 112MB 4 3GAA112320-··K 5.5 M3AA 132MB 4 3GAA132320-··K 7.5 M3AA 132MC 4 3GAA132330-··K 11 M3AA 160MLA 4 3GAA162410-··K 15 M3AA 160MLB 4 3GAA162420-··K 18.5 M3AA 180MLA 4 3GAA182410-··K 22 M3AA 180MLB 4 3GAA182420-··K 30 M3AA 200MLA 4 3GAA202410-··K 37 M3AA 225SMA 4 3GAA222210-··K 45 M3AA 225SMB 4 3GAA222220-··K 55 M3AA 250SMA 4 3GAA252210-··K 75 M3AA 280SMA 4 3GAA282210-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1748 1749 1748 1760 1759 1760 1769 1766 1780 1777 1783 1783 1783 1783 1784 1787 1784 460 V 60 Hz 85.5 84.4 86.5 85.4 86.5 85.1 89.5 89.2 89.5 89.3 89.5 89.4 91.7 91.7 91.7 91.6 92.4 92.2 93.0 92.6 93.6 93.7 93.8 94.2 94.1 94.0 94.5 94.7 95.0 94.9 95.7 95.8 95.4 95.5 81.6 82.5 82.0 87.4 87.4 88.0 90.5 90.8 90.9 91.2 93.1 93.7 93.0 94.1 95.0 95.2 94.8 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.74 1.48 9.5 4 3.8 4.5 0.0027 0.77 2 8.4 6 3.7 4.6 0.0055 0.75 2.9 9.5 8.1 4.0 5.0 0.0055 0.81 3.8 10.2 11.9 3.3 4.7 0.0144 0.81 5.2 10.4 16.3 3.8 4.9 0.0144 0.74 7.6 8.8 21.7 3.8 4.4 0.0176 0.75 10 8.0 29.7 3.0 4.5 0.0295 0.79 13 8.7 40.5 2.6 3.9 0.0414 0.80 18.9 8.7 59.1 3.4 3.7 0.11 0.79 25.7 8.9 80.6 3.3 4.1 0.135 0.82 30.3 8.4 99.0 3.1 3.5 0.219 0.82 35.8 9.3 117 3.0 3.4 0.217 0.83 48.2 8.5 161 2.8 3.9 0.385 0.83 59.3 8.8 198 3.6 3.5 0.427 0.83 71.8 8.8 241 2.9 4.7 0.525 0.84 85.8 9.1 293 3.3 3.7 0.933 0.82 120 9.1 401 4.0 4.3 0.941 Weight kg Sound pressure Level LPA dB 13.5 57 19 56 19 57 36 57 36 57 44 62 68 73 68 69 126 68 140 67 177 68 176 66 246 69 315 65 316 72 376 71 409 77 Output kW Motor type Product code 1800 r/min = 4 poles 18.5 M3AA 160MLC 4 3GAA162430-··K 30 M3AA 180MLC 4 3GAA182430-··K 37 M3AA 200MLB 4 3GAA202420-··K 55 M3AA 225SMC 4 3GAA222230-··K 75 M3AA 250SMB 4 3GAA252220-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1777 1780 1783 1782 1784 460 V 60 Hz 92.8 93.0 94.3 94.5 94.5 94.9 94.8 95.0 95.4 95.4 92.0 93.9 94.4 94.3 94.6 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.80 31.2 9.2 99.4 3.3 3.9 0.124 0.81 49 8.5 161 2.9 3.7 0.191 0.82 59.9 8.6 198 3.1 3.3 0.362 0.84 86.7 8.7 295 3.4 3.6 0.536 0.84 117 9.1 401 3.6 4.0 0.941 Weight kg Sound pressure Level LPA dB 135 71 176 65 244 68 318 75 389 77 ABB Motors and Generators | 9AKK105944 EN 02-2020 121 Technical data, 460V 60Hz IE3 Process performance aluminum motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014 Output kW Motor type Product code 1200 r/min = 6 poles 0.75 M3AA 90LD 6 3GAA093540-··K 1.1 M3AA 100LE 6 3GAA103550-··K 2.2 M3AA 112MC 6 3GAA113330-··K 3 M3AA 132MC 6 3GAA133330-··K 4 M3AA 132MD 6 3GAA133340-··K 5.5 M3AA 132ME 6 3GAA133350-··K 7.5 M3AA 160MLA 6 3GAA163410-··K 11 M3AA 160MLB 6 3GAA163420-··K 15 M3AA 180MLA 6 3GAA183410-··K 18.5 M3AA 200MLA 6 3GAA203410-··K 22 M3AA 200MLB 6 3GAA203420-··K 30 M3AA 225SMA 6 3GAA223210-··K 37 M3AA 250SMA 6 3GAA253210-··K 45 M3AA 280SMA 6 3GAA283210-··K 55 M3AA 280SMB 6 3GAA283220-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1148 1168 1172 1181 1176 1177 1182 1183 1189 1191 1191 1191 1192 1192 1191 460 V 60 Hz 82.5 81.9 87.5 87.5 89.5 89.6 89.5 89.4 89.5 89.9 91.0 91.3 91.4 91.5 91.7 91.8 92.3 92.0 93.3 93.2 93.8 93.8 94.2 94.3 94.5 94.7 94.5 94.5 94.5 94.7 79.6 85.8 88.4 88.1 88.9 90.4 90.3 90.5 90.5 92.1 92.8 93.6 94.1 93.6 94.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 CENELEC-design 0.73 1.56 5.1 6.2 2.2 2.8 0.0055 0.66 2.3 6.3 9 2.4 3.5 0.0138 0.66 4.6 7.3 17.9 2.5 4.0 0.0187 0.67 6.3 7.0 24.2 2.2 3.5 0.0402 0.69 8 6.2 32.4 2.0 3.0 0.0402 0.72 10.4 6.6 44.6 2.1 3.3 0.039 0.76 13.5 8.6 60.5 1.8 3.7 0.114 0.73 20.6 9.4 88.7 2.3 4.4 0.131 0.75 27.1 6.0 120 1.8 3.1 0.225 0.77 32.3 8.6 148 2.9 3.6 0.448 0.78 37.7 8.8 176 2.9 3.6 0.531 0.80 49.9 8.9 240 3.2 3.5 0.813 0.82 59.9 8.6 296 3.0 3.2 1.49 0.80 75 8.6 361 3.2 3.6 1.5 0.81 90.1 8.2 441 3.3 3.5 1.49 Weight kg Sound pressure Level LPA dB 19 61 35 52 43 71 66 64 67 64 63 64 125 63 139 63 175 63 218 67 245 67 310 67 367 67 398 72 399 72 Output kW Motor type Product code 1200 r/min = 6 poles 18.5 M3AA 180MLB 6 3GAA183420-··K 37 M3AA 225SMB 6 3GAA223220-··K 45 M3AA 250SMB 6 3GAA253220-··K 55 M3AA 250SMC 6 3GAA253230-··K Efficiency IEC 60034-30-1; 2014 Full Speed load r/min 100% 3/4 load 75% 1/2 load 50% 1183 1188 1192 1191 460 V 60 Hz 93.0 93.0 94.1 94.4 94.5 94.5 94.5 94.7 91.9 93.8 93.6 94.0 Current Power factor IN Cosj A IS/IN Torque TN Nm TI/TN Moment of inertia J = 1/4 Tb/TN GD2kgm2 High-output design 0.73 34.2 7.4 149 2.5 3.5 0.22 0.80 61.8 8.0 297 3.0 3.3 0.813 0.80 75 8.6 361 3.2 3.6 1.5 0.81 90.1 8.2 441 3.3 3.5 1.49 Weight kg Sound pressure Level LPA dB 168 69 307 72 389 72 390 72 122 9AKK105944 EN 02-2020 | ABB Motors and Generators Variant codes Aluminum motors Variant codes specify additional options and features to the standard motor. The desired features are listed as three-digit variant codes in the motor order. Note also that there are variants that cannot be used together. Most of the variant codes apply to IE2 and IE3 motors. However, confirm the availability of variants for IE3 motors with your ABB sales office before making an order. Variant codes for L generation motors on request! Code/Variants Administration 531 Sea freight packing 533 Wooden sea freight packing Balancing 417 Vibration acc. to Grade B (IEC 60034-14). 423 Balanced without key. 424 Full-key balancing Bearings and Lubrication 036 Transport lock for bearings. 037 Roller bearing at D-end. 039 Cold-resistant grease 040 Heat-resistant grease 041 Bearings regreasable via grease nipples. 043 SPM compatible nipples for vibration measurement 057 2RS bearings at both ends. 058 Angular contact bearing at D-end, shaft force away from bearing. 059 Angular contact bearing at N-end, shaft force towards bearing. 188 63-series bearing in D-end 593 Bearings grease suitable for food and beverage industry. 796 Grease nipples JIS B 1575 PT 1/8 Type A 797 Stainless steel SPM nipples 798 Stainless steel grease nipples Brakes 213 Brake with increased degree of protection. 412 Built-in brake. Branch standard designs 071 Cooling Tower duty 079 Silumin-alloy rotor cage. 142 Manilla connection. 178 Stainless steel / acid proof bolts. 199 Extreme heavy duty design. 209 Non-standard voltage or frequency, (special winding). 217 Cast iron D-end shield (on aluminum motor). 385 Paint free motor 425 Corrosion protected stator and rotor core. 983 Shock resistant design Cooling system 053 Metal fan cover. 068 Light alloy metal fan 075 Cooling method IC418 (without fan). 183 Separate motor cooling (fan axial, N-end). 189 Separate motor cooling, IP44, 400V, 50Hz (fan axial, N-end). Documentation 141 Binding 2D main dimension drawing. Drain holes 065 Plugged existing drain holes. Earthing Bolt = Included as standard = Available as option - = Not applicable Frame size 63 71 80 90 100 112 132 160 180 200 225 250 280 - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - -- - - - - - - - - - - - - -- - - - - - - - - - - - - -- - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - ABB Motors and Generators | 9AKK105944 EN 02-2020 123 Code/Variants 067 External earthing bolt. Hazardous Environments 334 Ex t, Dust group III B T125C Db, IP6X (non-conductive dust) acc. IEC/ EN60079-31. 335 Ex t, Dust group III B T125C Dc, IP5X (non-conductive dust) acc. IEC/ EN60079-31. 336 Ex t, Dust group III C T125 Db, IP6X (conductive dust) acc. IEC/ EN60079-31. 337 Ex t, Dust group III C T125 Dc, IP6X (conductive dust) acc. IEC/ EN60079-31. 340 Ex t, Dust group III B T125C Dc (non-conductive dust) with manufactur- ers declaration 456 Ex ec IIC T3 Gc acc. IEC/EN 60079-7 with certificates. 480 Ex nA II acc. to ATEX directive 2014/34/EU, temp. class T3. 804 DIP/Ex tD, IEC 61241, T125 ºC, IP55 (zone 22). 805 DIP/Ex tD, IEC 61241, T125 ºC, IP65 (zone 21). Heating elements 450 Heating element, 100-120 V 451 Heating element, 200 - 240 V Insulation system 014 Winding insulation class H. 405 Special winding insulation for frequency converter supply. 406 Winding insulation for supply > 690 <= 1000 volts Marine 024 Fulfilling Bureau Veritas (BV) requirements, with certificate. 025 Fulfilling Det Norske Veritas (DNV) requirements, with certificate. 026 Fulfilling Lloyds Register of Shipping (LR) requirements, with certifi- cate. 027 Fulfilling American Bureau of Shipping (ABS) requirements, with certificate. 049 Fulfilling Germanischer Lloyd (GL) requirements, with certificate. 050 Fulfilling Registro Italiano Navale (RINA) requirements, with certificate. 051 Fulfilling Russian Maritime Register of Shipping (RS) requirements, with certificate. 096 Fulfilling Lloyds Register of Shipping (LR) requirements, without cer- tificate (non-essential duty only) 186 Fulfilling Det Norske Veritas (DNV) requirements, without certificate 481 Fulfilling Nippon Kaiji Kyokai (NK) requirements, with certificate. 483 Fulfilling China Classification Societies (CCS) requirements (Beijing), with certificate. 484 Fulfilling Korea Register of Shipping (KR) requirements, with certifi- cate. 491 Fulfilling Nippon Kaiji Kyokai (NK) requirements, without certificate. 492 Fulfilling Registro Italiano Navale (RINA) requirements, without certifi- cate. 493 Fulfilling China Classification Societies (CCS) requirements (Beijing), without certificate. 494 Fulfilling Korea Register of Shipping (KR) requirements, without certifi- cate. 496 Fulfilling Bureau Veritas (BV) requirements, without certificate(non- essential duty only) 497 Fulfilling Russian Maritime Register of Shipping (RS) requirements, without certificate. 675 Fulfilling American Bureau of Shipping (ABS) requirements, without certificate (non-essential duty only) 676 Fulfilling Germanischer Lloyd (GL) requirements, without certificate (non-essential duty only) Mounting arrangements 007 IM 3001 flange mounted, IEC flange, from IM 1001 (B5 from B3). 008 IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3). 009 IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). 047 IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5). 048 IM 3001 flange mounted, IEC flange, from IM 3601 (B5 from B14). 066 Modified for specified mounting position differing from IM B3 (1001), IM B5 (3001), B14 (3601), IM B35 (2001), IM B34 (2101) 080 (IM 3001) Flange mounted, DIN A-flange. = Included as standard = Available as option - = Not applicable 124 9AKK105944 EN 02-2020 | ABB Motors and Generators Frame size 63 71 80 90 100 112 132 160 180 200 225 250 280 - - - - - - - - - - - - - - - -- - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - -- - - - - - - - - - -- Code/Variants 090 (IM 2101) foot/flange mounted, DIN C-flange, from IM 1001 (B34 from B3). 091 (IM 2001) foot/flange mounted, DIN A-flange, from IM 1001 (B35 from B3). 093 IM 3601 flange mounted, IEC flange, from IM 1001 (B14 from B3). 200 Flange ring holder. 218 Flange ring FT 85. 219 Flange ring FT 100. 220 Flange ring FF 100. 223 Flange ring FF 115. 224 Flange ring FT 115. 226 Flange ring FF 130. 227 Flange ring FT 130. 229 Flange FT 130. 233 Flange ring FF 165. 234 Flange ring FT 165. 235 Flange FF 165. 236 Flange FT 165. 243 Flange ring FF 215. 244 Flange ring FT 215. 245 Flange FF 215. 253 Flange ring FF 265. 254 Flange ring FT 265. 255 Flange FF 265. 260 Flange FT 115. 313 IM 3601 flange mounted, IEC flange, from IM 2101 (B14 from B34). 314 IM 3001 flange mounted, IEC flange, from IM 2101 (B5 from B34). 317 IM 3601 flange mounted, IEC flange, from IM 2001 (B14 from B35). Painting 114 Special paint color, standard grade Protection 005 Protective roof. 072 Radial seal at D-end. Not possible for 2-pole , 280 and 315 frames 158 Degree of protection IP65. 211 Weather protected, IP xx W 250 Degree of protection IP66 403 Degree of protection IP56. 404 Degree of protection IP56, without fan and fan cover. 784 Gamma-seal at D-end. Rating & instruction plates 002 Restamping voltage, frequency and output, continuous duty. 004 Additional text on std rating plate (max 12 digits on free text line). 095 Restamping output (maintained voltage, frequency), intermittent duty. 098 Stainless rating plate. 126 Tag plate 135 Mounting of additional identification plate, stainless. 138 Mounting of additional identification plate, aluminium. 139 Additional identification plate delivered loose. 159 Additional plate with text "Made in ...." 160 Additional rating plate affixed. 161 Additional rating plate delivered loose. 163 Frequency converter rating plate. Rating data according to quotation. 270 Additional rating plate with standard data, delivered loose 332 Baldor Catalogue # 333 Not for use in the USA 818 Restamping as generator Shaft & rotor 069 Two shaft extensions according to catalog drawings. 070 Special shaft extension at D-End, standard shaft material 131 Motor delivered with half key (key not exceeding shaft diameter) 165 Shaft extension with open keyway 410 Shaft material stainless steel = Included as standard = Available as option - = Not applicable Frame size 63 71 80 90 100 112 132 160 180 200 225 250 280 - - - - - - - - - -- - - - - - - - - - -- - - - - - - - - -- - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - -- - - - - - -- - - - - - - - - -- - - - - - - -- - - - - - -- - - - - - - - - - -- - - - - - - - - - -- - - - - - - - - -- - - - - - - - -- - - - - - - - - -- - - - - - - - - - -- - - - - - - - - - -- - - - - - - - - - -- - - - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ABB Motors and Generators | 9AKK105944 EN 02-2020 125 Code/Variants 591 Special shaft extension according to customer specification. 600 Special shaft extension at N-end, standard shaft material. Standards and Regulations 010 Fulfilling CSA Safety Certificate. 011 Fulfilling CSA Energy Efficiency Verification IE3 (code 010 included). 208 Fulfilling Underwriters Laboratories (UL), listed requirements 331 IE1 motor not for sale for use in EU 540 China energy label 542 NBR design 543 Australian MEPS 544 Australian HE MEPS 545 China Compulsory Certificate (CCC) 548 Certificate of conformity according TR-CU 004/2011 for customs union RU, KZ, BY, AM, KG. 822 WIMES 3.03i6 Compliant Design for DOL operation 823 WIMES 3.03i6 Compliant Design for VSD operation Stator winding temperature sensors 120 KTY 84-130 (1 per phase) in stator winding. 121 Bimetal detectors, break type (NCC), (3 in series), 130 ºC, in stator winding 122 Bimetal detectors, break type (NCC), (3 in series), 150 ºC, in stator winding 123 Bimetal detectors, break type (NCC), (3 in series), 170 ºC, in stator winding 124 Bimetal detectors, break type (NCC), (3 in series), 140 ºC, in stator winding 125 Bimetal detectors, break type (NCC), (2x3 in series), 150 ºC, in stator winding 127 Bimetal detectors, break type (NCC), (3 in series, 130 ºC & 3 in series, 150 ºC), in stator winding 321 Bimetal detectors, closing type (NO), (3 in parallel), 130ºC, in stator winding. 322 Bimetal detectors, closing type (NO), (3 in parallel), 150ºC, in stator winding. 323 Bimetal detectors, closing type (NO), (3 in parallel), 170ºC, in stator winding. 325 Bimetal detectors, closing type (NO), (2x3 in parallel), 150ºC, in stator winding. 327 Bimetal detectors, closing type (NO), (3 in parallel, 130ºC & 3 in parallel, 150ºC), in stator winding. 435 PTC - thermistors (3 in series), 130 ºC, in stator winding 436 PTC - thermistors (3 in series), 150 ºC, in stator winding 437 PTC - thermistors (3 in series), 170 ºC, in stator winding 439 PTC - thermistors (2x3 in series), 150 ºC, in stator winding 440 PTC - thermistors (3 in series, 110ºC & 3 in series, 130ºC), in stator winding. 441 PTC - thermistors (3 in series, 130 ºC & 3 in series, 150 ºC), in stator winding 442 PTC - thermistors (3 in series, 150 ºC & 3 in series, 170 ºC), in stator winding 445 Pt100 2-wire in stator winding, 1 per phase 446 Pt100 2-wire in stator winding, 2 per phase Terminal box 015 Motor supplied in D connection. 016 9 terminals in terminal box 017 Motor supplied in Y connection. 019 Larger than standard terminal box. 021 Terminal box LHS (seen from D-end). 022 Cable entry LHS (seen from D-end). 136 Extended cable connection, standard terminal box. 137 Extended cable connection, low terminal box, "Flying leads". 180 Terminal box RHS (seen from D-end). 230 Standard metal cable gland. 375 Standard plastic cable gland 376 Two standard plastic cable glands = Included as standard = Available as option - = Not applicable 126 9AKK105944 EN 02-2020 | ABB Motors and Generators Frame size 63 71 80 90 100 112 132 160 180 200 225 250 280 - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - -- - - - - - - - - - - - - - - -- - - - - - - -- Code/Variants 418 Separate terminal box for auxiliaries, standard material. 467 Lower than standard terminal box and rubber extended cable. Cable length 2 m 729 Aluminum non-drilled flange for cable glands 731 Two standard metal cable glands. 739 Prepared for metric cable glands according to DIN 42925, draft aug. 1999. 740 Prepared for PG cable glands. Testing 140 Test confirmation. 145 Type test report from a catalogue motor, 400V 50Hz. 146 Type test with report for one motor from specific delivery batch. 147 Type test with report for motor from specific delivery batch, customer witnessed. 148 Routine test report. 153 Reduced test for classification society. 221 Type test and multi-point load test with report for one motor from specific delivery batch. 222 Torque/speed curve, type test and multi-point load test with report for one motor from specific delivery batch. 760 Vibration level test 762 Noise level test for one motor from specific delivery batch. 763 Noise spectrum test for one motor from specific delivery batch. Variable speed drives 470 Prepared for hollow shaft pulse tacho (L&L equivalent). 472 1024 pulse tacho (L&L 861007455-1024). 473 2048 pulse tacho (L&L 861007455-2048). 474 Separate motor cooling (axial fan, N-end) and prepared for hollow shaft tacho (L&L equivalent) 476 Separate motor cooling (axial fan, N-end) and 1024 pulse tacho (L&L 861007455-1024) 477 Separate motor cooling (axial fan, N-end) and 2048 pulse tacho (L&L 861007455-2048) 570 Prepared for hollow shaft pulse tacho (L&L 503). 572 1024 pulse tacho (L&L 503). 573 2048 pulse tacho (L&L 503). 574 Separate motor cooling (fan axial, N-end) and prepared for hollow shaft tacho (L&L 503). 576 Separate motor cooling (fan axial, N-end) and 1024 pulse tacho (L&L 503). 577 Separate motor cooling (fan axial, N-end) and 2048 pulse tacho (L&L 503). 580 Separate motor cooling, IP44, 400 V, 50Hz (axial fan, N-end) and 1024 pulse tacho (L&L 503) 581 Separate motor cooling, IP44, 400V, 50Hz (fan axial, N-end) and 2048 pulse tacho (L&L 503). 588 Shaft grounding device 661 1024 Pulse tacho mounted, Hohner series 59, 11-30V 662 2048 Pulse tacho mounted, Hohner series 59, 11-30V 701 Insulated bearing at N-end. 702 Insulated bearings at both ends 704 EMC cable entry. = Included as standard = Available as option - = Not applicable Frame size 63 71 80 90 100 112 132 160 180 200 225 250 280 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - -- - - - - - - - - - - - - - - - - - -- - - ABB Motors and Generators | 9AKK105944 EN 02-2020 127 Mechanical design Motor frame and drain holes Motor frame The motor frame is made of aluminum alloy. Frame sizes 63 to 180 have aluminum feet and sizes 200 to 280 have cast iron feet. The bearing end shields of sizes 63 to 132 are made of aluminum, and those of 160 to 280 are made of cast iron. Drain holes Motors that will be operated in very humid or wet environments and especially under intermittent duty should be provided with drain holes. The IM designation, such as IM 3031, determines the intended mounting arrangement for the motor. Motors are provided with closable plastic plugs in the drain holes. The plugs on delivery, when mounting the motors, ensure that the drainholes face downwards. In the case of vertical mounting, the upper plug must be hammered home completely. In very dusty environments both plugs should be hammered home. Motors are supplied with drain holes both at the D-end and N-end. When mounting arrangement differs from foot mountedIM B3, please use variant code 066 when ordering.See variant codes 065, 066 and 076 under the heading "Drain holes". Open Open Closed Open 128 9AKK105944 EN 02-2020 | ABB Motors and Generators Mechanical design Bearings The motors are provided with bearings according to the tables below. Greater axial forces can be tolerated if the motors are provided with angular contact ball bearings. Standard design: deep groove ball bearings Motor size 63 71 80 90 100 1121) 1122) 132 3) 132 4) 160 180 200 225 250 280 2 pole 280 4-8 pole 1)all types except 2)112 J-gen 3)all types except 4)SM_ Foot- and flange-mounted motor D-end 6201-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6306-2Z/C3 6306-2Z/C3 6206-2Z/C3 6208-2Z/C3 6308-2Z/C3 6309-2Z/C3 6310-2Z/C3 6312-2Z/C3 6313-2Z/C3 6315-2Z/C3 6315/C3 6316/C3 N-end 6201-2Z/C3 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6205-2Z/C3 6205-2Z/C3 6206-2Z/C3 6206-2Z/C3 6209-2Z/C3 6209-2Z/C3 6210-2Z/C3 6212-2Z/C3 6213-2Z/C3 6213/C3 6213/C3 Note that in such cases the axial force must only operate in one direction. Motor versions with roller bearings tolerate greater radial forces. Alternative design with roller bearings It is recommended to use roller bearings in belt drives for motor sizes 160 to 280. See variant code 037 under the heading "Bearings and lubrication". Motor size 63 71 80 90 100 1121) 1122) 1)all types except 2)112 J-gen 3)all types except 4)SM_ Foot- and flange-mounted motor D-end NU 205 NU 306 NU 306 NU 206 N-end 6201-2Z/C3 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6205-2Z/C3 6205-2Z/C3 Motor size 132 3) 132 4) 160 180 200 225 250 280 2 pole 280 4-8 pole 1)all types except 2)112 J-gen 3)all types except 4)SM_ Foot- and flange-mounted motor D-end NU 208 NU 308 NU 309 ECP NU 310 ECP NU 312 ECP NU 313 ECP NU 315 ECP NU 315 ECP NU 316 ECP N-end 6206-2Z/C3 6206-2Z/C3 6209-2Z/C3 6209-2Z/C3 6210-2Z/C3 6212-2Z/C3 6213-2Z/C3 6213/C3 6213/C3 Alternative design: angular contact ball bearings See variant codes 058 and 059 under the heading "Bearings and lubrication". Motor size 63 71 80 90 100 1121) 1122) 132 3) 132 4) 160 180 200 225 250 280 2 pole 280 4-8 pole 1)all types except 2)112 J-gen 3)all types except 4)SM_ D-end 058 7205 B 7306 B 7306 B 7206 B 7208 B 7308 B 7309 BEP 7310 BEP 7312 BEP 7313 BEP 7315 BEP 7315 BEP 7316 BEP N-end 059 7204 B 7205 B 7205 B 7205 B 7206 B 7206 B 7209 BEP 7209 BEP 7210 BEP 7212 BEP 7213 BEP 7213 BEP 7213 BEP Transport locking Motors provided with roller bearings or angular contact ball bearings are fitted with a transport lock to prevent damage to the bearings, due to vibration, during transport. Axially locked bearings The table below shows which of the motor's bearings are axially locked in the bearing seat. In motor size 63 the locking is done by an internal ABB Motors and Generators | 9AKK105944 EN 02-2020 129 01 Motor sizes 71 - 132. 02 Motor sizes 160 - 250. retaining ring, in motor sizes 71 to 280 by an inner bearing cover. Motor size 63 71-132 160-280 Foot-mounted motors On request at D-end D-end 1) D-end Flange-mounted motors Large flange Small flange On request at On request at D-end D-end D-end 1) D-end 1) D-end - 1) A spring-washer at the N-end presses the rotor toward the D-end. Bearing seals Motor size 71 80 90 100 112 132 160 180 200 225 250 Number of poles Standard design, axial seal D-end N-end Alternative design Radial seal (Din3760) Variant code 073 2-12 V-16A Labyrinth seal 17x28x7 2-12 V-20A Labyrinth seal 20x40x7 2-12 V-25A Labyrinth seal 25x42x7 2-12 V-30A Labyrinth seal 30x47x7 2-12 V-30A Labyrinth seal 30x47x7 2-12 V-40A Labyrinth seal 40x62x7 2-12 V-45A V-45A 45x65x8 2-12 V-50A V-45A 50x72x8 2-12 V-60A V-50A 60x80x8 2-12 V-65A V-60A 65x85x8 2-12 V-75A V-65A 75x95x8 __ __ 01 02 130 9AKK105944 EN 02-2020 | ABB Motors and Generators Bearing life and lubrication Bearing life The nominal life is defined as the number of hours that are attained or exceeded by 90 percent of identical bearings, in a large test series, under certain specified conditions.50 percent of the bearings attain a life of as much as5 times this figure. The life of bearings is dependent on various factors such as bearing load, motor speed, operating temperature and the purity of the grease. The permissible radial and axial loading for different motor sizes is shown in the table on the following pages. The table is valid for 50 Hz. For 60 Hz and/or some other bearing life than specified in the table the values are changed according to the table below. The table values assume the occurrence of only radial or axial forces. In the case of simultaneous radial and axial forces information can be supplied on request. It is assumed that the radial force is applied at the end of the motor shaft. Permissible force at changed bearing life or supply frequency Bearing life in hours at 50 Hz 25 000 40 000 63 000 80 000 60 Hz 21 000 33 000 52 000 67 000 100 % of value for 25.000 hours 100 % of value for 40.000 hours 86 % of value for 40.000 hours 80 % of value for 40.000 hours Lubrication The motors are delivered with bearing grease for use at normal temperatures in dry or humid environments. The motors are lubricated for ambient temperatures 40°C and in other temperatures above 40°C, see table next page. Motor sizes 63 to 250 are provided with shielded bearings. As an option, motor sizes 90 to 250 are provided with grease nipples for regreasing, see variant code 041 under the heading "Bearings and lubrications". Motor size 280 is provided with grease nipples for re-greasing as standard. The lubrication interval L1, suitable for relubricated bearings, is defined as the number of operating hours after which 99 percent of the bearings are adequately lubricated. Lubrication intervals and grease quantities are specified on a plate on the motor as well as in the manual supplied with the motor. The grease lifetime L10, suitable for permanent lubricated bearings, is defined as the number of operating hours after which 90 percent of the bearings are adequately lubricated. 50 percent of the bearings achieve two times this figure. Maximum lifetime, however, should be regarded as 40,000 hours. In case of high ambient temperatures the shaft loads must be reduced compared to permissible loadings in the table, please contact ABB. Lubrication intervals ABB follows the L1-principle in defining lubrication interval. That means that 99 percent of the motors are sure to make the interval time. The lubrication intervals can also be calculated according to the L10-principle, which are normally doubled compared to L1-values. Values available from ABB at request. The table below gives lubrication intervals according to the L1-principle for different speeds. The values are valid for horizontal mounted motors (B3), with about 80°C bearing temperature and using good quality grease with lithium complex soap and with mineral or PAO-oil. For more information, see ABB's Low Voltage Motors Manual. ABB Motors and Generators | 9AKK105944 EN 02-2020 131 Lubrication intervals for ball and roller bearings Amount of Frame size grease g 3600 r/min 3000 r/min Ball bearings: lubrication intervals in duty hours 280 60 2000 3500 280 70 - - Roller bearings: lubrication intervals in duty hours 280 60 1000 1750 280 70 - - 1800 r/min 8000 4000 1500 r/min 10 500 5250 1000 r/min 500-750 r/min 14 000 17 000 7000 8500 Grease lifetime In vertically mounted motors, the grease lifetime is half the figures as in following table. For applications corresponding to the empty cells in the table, please contact ABB. These applications can imply reduced lifetime for bearings and winding. Motors with roller bearings (optional) have considerably shorter grease life. For continuous operation regreasing nipples should be considered. 132 9AKK105944 EN 02-2020 | ABB Motors and Generators Grease lifetime Ambient temperature and rated output 25 °C 40 °C 50 °C 60 °C 70 °C 80 °C Motor 63 71 80 90 100 1121) 1122) 132 3) 132 4) 160 180 200 r/min 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 Basic 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 38 000 40 000 40 000 40 000 27 000 40 000 40 000 40 000 High 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 38 000 40 000 40 000 27 000 40 000 40 000 Basic 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 39 000 40 000 40 000 40 000 39 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 33 000 40 000 40 000 40 000 31 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 38 000 40 000 40 000 40 000 27 000 40 000 40 000 40 000 High 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 39 000 40 000 40 000 40 000 39 000 40 000 40 000 40 000 40 000 40 000 35 000 35 000 33 000 40 000 40 000 40 000 31 000 40 000 40 000 40 000 36 000 40 000 40 000 38 000 40 000 40 000 27 000 40 000 40 000 Basic 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 39 000 40 000 40 000 40 000 33 000 40 000 40 000 40 000 25 000 40 000 40 000 40 000 25 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 21 000 40 000 40 000 40 000 20 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 38 000 40 000 40 000 40 000 27 000 40 000 40 000 40 000 High 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 39 000 40 000 40 000 40 000 33 000 40 000 40 000 40 000 25 000 40 000 40 000 40 000 25 000 40 000 40 000 40 000 30 000 21 000 40 000 40 000 40 000 20 000 40 000 40 000 40 000 19 000 40 000 40 000 38 000 24 000 40 000 18 000 40 000 40 000 Basic 31 000 33 000 33 000 33 000 27 000 33 000 33 000 33 000 23 000 33 000 33 000 33 000 20 000 33 000 33 000 33 000 15 000 30 000 33 000 33 000 15 000 30 000 33 000 33 000 26 000 27 000 40 000 40 000 13 000 26 000 33 000 33 000 12 000 24 000 33 000 33 000 26 000 40 000 40 000 40 000 38 000 40 000 40 000 40 000 24 000 40 000 40 000 40 000 High 31 000 33 000 33 000 33 000 27 000 33 000 33 000 33 000 23 000 33 000 33 000 33 000 20 000 33 000 33 000 33 000 15 000 30 000 33 000 33 000 15 000 30 000 33 000 33 000 17 000 13 000 26 000 33 000 33 000 12 000 24 000 33 000 33 000 9000 38 000 40 000 23 000 12 000 40 000 10 000 32000 40 000 Basic 17 000 18 000 18 000 18 000 15 000 18 000 18 000 18 000 13 000 18 000 18 000 18 000 11 000 18 000 18 000 18 000 8000 17 000 18 000 18 000 8000 17 000 18 000 18 000 7000 14 000 18 000 18 000 6000 13 000 18 000 18 000 14 000 40 000 40 000 40 000 23 000 26 000 40 000 37000 14 000 40 000 40 000 40 000 High 17 000 18 000 18 000 18 000 15 000 18 000 18 000 18 000 13 000 18 000 18 000 18 000 11 000 18 000 18 000 18 000 8000 17 000 18 000 18 000 8000 17 000 18 000 18 000 7000 14 000 18 000 18 000 6000 13 000 18 000 18 000 5000 20 000 24 000 12 000 6000 24 000 5000 18 000 30 000 Basic 9000 9000 9000 9000 8000 9000 9000 9000 7000 9000 9000 9000 6000 9000 9000 9000 4000 9000 9000 9000 4000 9000 9000 9000 High 9000 9000 9000 9000 8000 9000 9000 9000 7000 9000 9000 9000 6000 9000 9000 9000 4000 9000 9000 9000 4000 9000 9000 9000 4000 4000 7000 7000 9000 9000 9000 9000 3000 3000 7000 7000 9000 9000 9000 9000 8000 2000 37000 10 000 40 000 12 000 40 000 13 000 7000 13 000 3000 29 000 12 000 21 000 8000 3000 30 000 10 000 38 000 17 000 40 000 1) all types except 2)112 J-gen 3)all types except 4)SM_ ABB Motors and Generators | 9AKK105944 EN 02-2020 133 Grease lifetime Ambient temperature and rated output 25 °C 40 °C 50 °C 60 °C 70 °C 80 °C Motor 225 250 r/min 3000 1500 1000 750 3000 1500 1000 750 Basic 23 000 40 000 40 000 40 000 16 000 40 000 40 000 40 000 High 23 000 40 000 40 000 16 000 40 000 40 000 Basic 23 000 40 000 40 000 40 000 16 000 40 000 40 000 40 000 High 18 000 40 000 40 000 13 000 39 000 40 000 Basic 23 000 40 000 40 000 40 000 16 000 40 000 40 000 40 000 High 10 000 23 000 40 000 7000 21 000 40 000 Basic 20 000 40 000 40 000 40 000 12 000 40 000 40 000 40 000 High 6000 12 000 40 000 4000 11 000 40 000 Basic 12 000 40 000 40 000 40 000 7000 33 000 40 000 40 000 High 3000 6000 40 000 2000 6000 25 000 Basic High 7000 1000 25 000 3000 40 000 27 000 40 000 4000 1000 19 000 3000 36 000 13 000 40 000 1) all types except 2)112 J-gen 3)all types except 4)SM_ Grease lifetime L10 in deep groove ball bearings of type 2Z in horizontally mounted motors in continu- ous running duty. 134 9AKK105944 EN 02-2020 | ABB Motors and Generators Mechanical design Radial forces Permissible loading on shaft The tables give the permissible radial force in Newtons, assuming zero axial force, ambient temperature of 25°C. Permissible loads of simultaneous radial and axial forces will be supplied on request. The bearing life, L10, is calculated according to SKF's theory on bearing life L10aah, which also takes the purity of the grease into consideration. An adequate lubrication is a necessary prerequisite for the table at right. If the radial force is applied between points X0 and Xmax, the permissible force FR can be calculated from the following formula: X FR = FX0 - E (FX0 - F ) Xmax Where: E: length of the shaft extension in the standard version FR X F Xmax F X0 ABB Motors and Generators | 9AKK105944 EN 02-2020 135 Permissible radial forces Motor size 63 71 80 80 90 100 112 1121) 132 2) 132 3) Poles 2-8 2-8 2 4-8 2-8 2-8 2-8 2-6 2-8 2-8 1) 112 J-gen 2) 62-series bearings 3)63-series bearings Length of shaft extension E (mm) 23 30 40 40 50 60 60 60 80 80 Ball bearings Basic design with deep groove ball bearings 25000 hours 40000 hours FX0 (N) 490 680 630 930 1010 2280 2280 1770 2120 2600 FXmax (N) 400 570 750 750 810 1800 1800 1430 1610 2100 FX0 (N) 490 680 930 930 1010 2280 2280 1560 2120 2600 FXmax (N) 400 570 750 750 810 1800 1800 1260 1610 2100 Motor size Poles 160 2 4 6 8 180 2 4 6 8 200 2 4 6 8 225 2 4 6 8 250 2 4 6 8 280 2 4 6 8 Ball bearings Basic design with deep groove ball Length bearings of shaft 20 000 hrs extension 40 000 hrs E (mm) FX0(N) FXmax(N) FX0(N) FXmax(N) 110 4760 3860 4100 3320 110 5180 4200 4380 3545 110 5160 4180 4360 3540 110 6280 4300 5320 4300 110 6060 4960 5280 1) 4305 1) 110 4800 3940 4020 3300 110 6280 5140 5280 4380 110 6960 5500 5880 4800 110 7800 6500 6760 2) 5640 2) 110 8400 7020 7180 5980 110 8960 7480 7600 6340 110 10480 8740 8940 7400 110 8520 7180 7360 3) 6200 3) 140 8380 6780 7200 5820 140 10 960 8860 9360 7560 140 12 100 9780 10 340 8360 140 10 480 4) 8500 4) 9080 4) 7360 4) 140 10 840 8780 9380 7600 140 12 600 10 220 10 700 8680 140 14 660 11 880 12 540 10 160 140 6780 5500 5680 4600 140 8060 6540 6640 5380 140 8980 7280 7360 5960 140 9180 7460 7460 6060 1) The maximum lifetime of the grease is 38000 h 2) The maximum lifetime of the grease is 27000 h 3) The maximum lifetime of the grease is 23000 h 4) The maximum lifetime of the grease is 16000 h Roller bearings Alternative design with roller bearings 20 000 hrs 40 000 hrs FX0(N) 6580 7340 7780 8860 7600 7280 8680 9440 10 360 11 560 12 480 14 100 12 320 13 380 15 860 17 220 16 220 18 020 20 240 22 680 16 280 19 480 21 920 22 240 FXmax(N) 4300 4300 4300 4300 5500 5500 5500 5500 8640 9550 9550 9550 10 380 10 250 10 250 10 250 10 900 13 800 13 800 13 800 13 200 15 780 17 760 18 020 FX0(N) 5620 6180 6500 7440 6560 6140 7280 7920 8880 9800 10 520 11 920 10 560 11 320 13 420 14 580 13 960 15 320 17 140 19 220 14 000 16 540 18 580 18 860 FXmax(N) 4300 4300 4300 4300 5500 5500 5500 5500 7400 8180 8780 9550 8900 9160 10 250 10 250 10 900 13 800 13 800 13 800 11 360 13 400 15 060 15 300 136 9AKK105944 EN 02-2020 | ABB Motors and Generators Mechanical design Axial forces 01 Mounting arrangement IM B3. 02 Mounting arrangement IM V1. The following tables present permissible axial forces on the shaft in Newtons, assuming zero radial force, a 25 °C ambient temperature, and normal conditions. The values are given for a calculated bearing life of 20,000 and 40,000 hours per motor size. At 60 Hz, the values must be reduced by 10 percent, and for two-speed motors, the higher speed determines permissible axial force. Permissible loads of simultaneous radial and axial forces can be supplied on request. For axial force FAD, it is assumed that the D-bearing is locked with a locking ring. FAZ FAD FAD FAZ __ __ 01 02 Permissible axial forces Motor size 63 71 80 90 100 Mounting arrangement IM B3, deep groove ball bearings 20 000 hours 40 000 hours Poles 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 FAD (N) 480 565 580 590 625 780 890 985 810 1015 1170 1300 885 1170 1270 1410 1620 2065 2390 2660 FAZ (N) 125 165 190 195 325 480 590 685 470 675 830 960 485 650 870 1010 1120 1565 1890 2160 FAD (N) 420 470 490 590 515 630 710 780 650 810 925 1015 720 945 1005 1110 1280 1615 1860 2065 FAZ (N) 105 115 145 205 215 330 410 480 315 470 595 675 320 425 605 710 780 1115 1360 1565 Mounting arrangement IM V1, deep groove ball bearings 20 000 hours 40 000 hours FAD (N) 495 585 600 FAZ (N) 115 155 180 FAD (N) 440 490 550 FAZ (N) 95 105 115 640 800 925 1020 845 1075 1225 1350 945 1245 1360 1485 1710 2180 2510 2780 315 470 570 665 450 640 795 925 450 600 815 960 1060 1485 1815 2080 530 650 745 815 690 865 980 1070 775 1020 1095 1185 1370 1735 1980 2185 200 320 390 455 290 430 550 645 280 375 550 660 715 1035 1285 1485 ABB Motors and Generators | 9AKK105944 EN 02-2020 137 Permissible axial forces Mounting arrangement IM B3, deep groove ball bearings Motor size Poles 112 M, 2 MB 4 6 8 112 J- 2 gen 4 6 8 132 M, 4 MA 6 8 132 MC 6 132 MBA 4 132 S 6 8 132 SB 2 132 SBB, 2 SC 132 2 SMB, 4 SMC 132 SMD 4 132 SME 2 160 2 4 6 8 180 2 4 6 8 200 2 4 6 8 225 2 4 6 8 250 2 4 6 8 280 2 4 6 8 20 000 hours FAD (N) 1615 2060 2385 2655 1500 1600 1720 1760 2245 2595 2875 2580 2235 2600 2885 1760 1760 FAZ (N) 1115 1560 1885 2155 1000 1100 1220 1260 1645 1980 2270 1980 1635 2000 2285 1160 1160 2210 2840 2830 2210 4160 4740 4840 5980 5480 4360 5980 6000 5000 5000 5000 5000 5000 5000 5000 5000 6000 4) 6000 6000 6000 5260 6500 7500 7740 1610 2240 2200 1610 4160 4740 4840 5980 5480 4360 5980 6620 6880 7660 8300 9880 7380 7600 10140 11 420 9020 4) 9800 11520 13 700 5260 6500 7500 7740 40 000 hours FAD (N) 1275 1610 1860 2060 1160 2160 1380 1420 1760 2025 2240 2010 1750 2030 2245 1400 1395 FAZ (N) 775 1110 1360 1560 660 760 880 920 1160 1425 1640 1410 1150 1435 1645 800 795 1740 2205 2230 1730 3425 3920 4000 4920 4600 1) 3540 4940 5460 5000 2) 5000 5000 5000 5000 3) 5000 5000 5000 6000 4) 6000 6000 6000 4220 5160 6040 6180 1140 1605 1595 1130 3425 3920 4000 4920 4600 1) 3540 4630 5460 5700 2) 6340 6880 8160 6120 3) 6220 8420 9460 7500 4) 8040 9520 11 380 4220 5160 6040 6180 1) The maximum lifetime of the grease is 38 000 h 2) The maximum lifetime of the grease is 27 000 h 3) The maximum lifetime of the grease is 23 000 h 4) The maximum lifetime of the grease is 16 000 h Mounting arrangement IM V1, deep groove ball bearings 20 000 hours 40 000 hours FAD (N) 1725 2210 2540 2790 1610 2100 2430 2880 2460 2815 3130 2885 2495 2780 3100 1910 1945 FAZ (N) 1040 1460 1785 2055 1010 1430 1760 1740 1505 1850 2115 1780 1465 1885 2145 1075 1045 FAD (N) 1385 1110 2010 2195 1260 985 1885 2075 1970 2245 2490 2315 2010 2210 2460 1540 1575 FAZ (N) 700 1010 1260 1475 675 885 1135 1325 1015 1280 1470 1210 980 1315 1505 705 670 2435 3150 3195 2490 4560 5260 5400 6560 5920 5080 6000 6000 5000 5000 5000 5000 5000 5000 5000 5000 6000 4) 6000 6000 6000 6400 7920 8500 8500 1470 2035 1995 1425 3810 4310 4420 5580 5115 3860 5445 6120 6350 6950 7505 9215 6770 6795 9270 10 595 8335 4) 8820 10 275 12 645 4400 5400 6180 6435 1950 2515 2560 2005 3860 4440 4540 5460 5060 1) 4240 5600 6000 5000 2) 5000 5000 5000 5000 3) 5000 5000 5000 6000 4) 6000 6000 6000 5420 6640 7840 7980 985 1400 1355 940 3110 3490 3560 4480 4255 1) 3020 4385 4900 5230 2) 5650 6025 7435 5490 3) 5475 7490 8535 6755 4) 7120 8235 10 205 3420 4120 4640 4775 138 9AKK105944 EN 02-2020 | ABB Motors and Generators Mechanical design Terminal box Sizes 63 to 180 The terminal box is made of aluminum alloy and is located on top of the stator. The lower part of the box is integrated with the stator. It is provided with two knockout openings on each side. Sizes 132 SM_ and 160 - 180 also have a third smaller opening. Cable glands are not included. Sizes 200 to 280 The terminal box and cover are made of deep drawn steel and mounted on top of the stator. The box is bolted to the stator and is not rotatable. The size of the box is the same for all frame sizes. The motors can also be provided with an extra large terminal box, standard for voltage code S and frame size 280. See variant code 019 under the heading "Terminal box". This will increase the dimension HD by 32 mm. The box is supplied with two FL 21 openings. The right opening is provided with a flange with two holes for M63 cable glands. The holes are sealed by means of plastic plugs. Cable glands are not supplied. The opening on the other side is provided with a cover flange. The box can also be provided with an FL 13 opening towards the N-end. When new motors are manufactured the terminal box can be mounted on the left or the right side. See variant codes 021 and 180 under the heading "Terminal box". In the basic design the terminal box is provided with twoFL 13 flange openings, one on each side. The opening on the right side, seen from the Dend, is supplied with a flange with two holes for M40 cable glands. On delivery the holes are sealed by means of plastic plugs. Cable glands are not supplied. The opening on the other side is provided with a cover flange. Dimensions for terminal box Dimensions Motor size HB HD HE Code 019: Larger than standard terminal box 200 ML 332.5 603 240 225 SM 353 578 260.5 250 SM 376 626 283.5 Code 021: Terminal box on left-hand side seen from D end Code 180: Terminal box on right-hand side seen from D end 200 ML 332 532 239 225 SM 354 579 260.5 250 SM 377 627 284 Code 467: Lower than standard terminal box without screw terminals and extended rubber connection cable 2 m. 160 211.5 371.5 180 226.5 406.5 200 ML 248 448 225 SM 269 494 250 SM 292 542 280 292 572 Refer to the Dimension drawings section for dimensions HB, HD and HE. ABB Motors and Generators | 9AKK105944 EN 02-2020 139 01 Terminal board for motor sizes 63 to 80. Connections 02 Terminal board for motor sizes 90 to 112. 03 Terminal board for motor size 132. 04 Terminal board for motor sizes 160 to 180 in G-generation. 05 Terminal board for motor sizes 160 to 200 in L-generation. 06 Terminal board for motor sizes 200 to 280 in G-generation. __ __ 01 05 07 Terminal board for motor sizes 225 to 280 in L-generation. __ __ 02 06 __ __ 03 07 The terminal block is provided with six terminals for connecting Cu-cable. The terminals are marked in accordance with IEC 60034-8. __ 04 140 9AKK105944 EN 02-2020 | ABB Motors and Generators Connection openings Motor size 63 Opening Knock-out opening 71-80 90-112 132 1) 132 2) 160-180 200-250 280 Knock-out opening Knock-out opening Knock-out opening Knock-out opening Knock-out opening 2 x FL 13 2 x FL 21 1) All types except 2) 2) SM_ Metric cable entry 1 x M16 x 1.5 1 x Pg 11 2 x ( 2 x M20 ) 2 x (M25 + M20) 2 x (M25 + M20) 2 x (M40 x M32 + M12) 2 x (2 x M40) + M16 1 x (2 x M40 + M16) 1 x (2 x M63 + M16) Method of connection Cable lug Terminal bolt size Maximum connectable Cu-cable area, mm 2 M4 2.5 Cable lug M4 4 Screw terminal M4 6 Cable lug M5 10 Cable lug M6 35 Cable lug M6 35 Cable lug M10 70 Cable lug M10 70 ABB Motors and Generators | 9AKK105944 EN 02-2020 141 Dimension drawings Process performance IE2 aluminum motors Foot-mounted motor IM1001, B3 and flange-mounted motor IM3001, B5 Motor size Poles D 63 11 71 14 80 19 90 S 8 24 90 L2, L8, LB 2-8 24 90 LD 4-6 24 100 LB2, LC 4-8, LA8, LB8 28 100 LD 4 28 112 28 132 SB2, M4, MA4, MBA4 38 132 SC2, MC6 38 132 SM_ 38 160 MLA 2-8, MLB2, MLB8 42 160 MLB 4-6, MLC 2-8, MLD 2-4 42 180 48 200 55 225 55 225 60 250 60 250 65 280 65 280 75 GA F 12.5 4 12.5 5 21.5 6 27 8 27 8 27 8 31 8 31 8 31 8 41 10 41 10 41 10 45 12 45 12 51.5 14 59 16 59 16 63 18 64 18 69 18 69 18 79.5 20 E L max A B B1 C HD K 23 217 100 80 40 169 7 30 240 112 90 45 180 7 40 265.5 125 100 50 193.5 10 50 284.5 140 125 56 217 10 50 309.5 140 125 56 217 10 50 331.5 140 125 56 217 10 60 351 160 140 63 237 12 60 373 160 140 63 237 12 60 393 190 140 70 249 12 80 447 216 140 178 89 295.5 12 80 487 216 140 178 89 295.5 12 80 550 216 140 178 89 321 12 110 584 254 210 254 108 370 15 110 681 254 210 254 108 370 15 110 726 279 241 279 121 405 15 110 821 318 267 305 133 532 18 110 850 356 286 311 149 579 18 140 880 356 286 311 149 579 18 140 884 406 406 349 168 627 22 140 884 406 406 349 168 627 22 140 884 457 457 419 190 657 24 140 884 457 457 419 190 657 24 MN P S 115 95 140 7 130 110 160 10 165 130 200 12 165 130 200 12 165 130 200 12 165 130 200 12 215 180 250 15 215 180 250 15 215 180 250 15 265 230 300 14.5 265 230 300 14.5 265 230 300 14.5 300 250 350 19 300 250 350 19 300 250 350 19 400 350 400 19 400 350 450 19 400 350 450 19 500 450 550 19 500 450 550 19 500 450 550 19 500 450 550 19 IMB14 (IM3601) Motor size M N 63 75 60 71 85 70 80 100 80 90 115 95 P S 90 5 105 6 120 6 140 8 Motor size M N P S 100 130 110 160 8 112 130 110 160 8 132 165 130 200 10 132SM_ 165 130 200 10 Tolerances A, B D ±0,8 ISO j6 Ø 28 mm ISO k6 < Ø 38 mm ISO m6 Ø 55 mm Tolerances F ISO h9 H -0,5 N ISO js6 C ±0,8 The table gives the main dimension in mm. For detailed drawings please see our web pages www.abb.com/motors&generators. 142 9AKK105944 EN 02-2020 | ABB Motors and Generators Dimension drawings Process performance IE3 aluminum motors, J/L-generation Foot-mounted motor IM1001, B3 and flange-mounted motor IM3001, B5 Motor size 80 80 90 90 100 100 112 112 132 132 160 160 180 200 225 225 250 250 280 280 Poles B 2, C2 E 4 L2, L8, LB2-8 LD4-6 LC4 LB2, LC6, LD 4 MB2 MB4-6 S6, M4, MA4 SB2, SC2, MA6, MC6 MLA2 MLB2, MLC2, 4-6 p 2 pole 4-6 poles 2 pole 4-6 poles 2 pole 4-6 poles D GA F E L max A B B1 C HD K 19 21.5 6 40 265.5 125 100 50 193.5 10 19 21.5 6 40 293 125 100 50 193.5 10 24 27 8 50 309.5 140 125 56 217 10 24 27 8 50 331.5 140 125 56 217 10 28 31 8 60 351 160 140 63 237 12 28 31 8 60 393 160 140 63 237 12 28 31 8 60 390 190 140 70 258 12 28 31 8 60 410 190 140 70 258 12 38 41 10 80 447 216 140 178 89 295.5 12 38 41 10 80 487 216 140 178 89 295.5 12 42 45 12 110 584 254 210 254 108 370 15 42 45 12 110 681 254 210 254 108 370 15 48 51.5 14 110 681 279 241 279 121 390 15 55 59 16 110 726 318 267 305 133 425 18 55 59 16 110 821 356 286 311 149 531 18 60 64 18 140 851 356 286 311 149 531 18 60 64 18 140 880 406 311 349 168 578 22 65 69 18 140 880 406 311 349 168 578 22 65 69 18 140 884 457 457 419 190 631 24 75 79.5 20 140 884 457 457 419 190 631 24 MN P S 165 130 200 12 165 130 200 12 165 130 200 12 165 130 200 12 215 180 250 15 215 180 250 15 215 180 250 15 215 180 250 15 265 230 300 14.5 265 230 300 14.5 300 250 350 19 300 250 350 19 300 250 350 19 400 350 400 19 400 350 450 19 400 350 450 19 500 450 550 19 500 450 550 19 500 450 550 19 500 450 550 19 IMB14 (IM3601) Motor size M N P S 80 100 80 120 6 90 115 95 140 8 100 130 110 160 8 Motor size M N P S 112 130 110 160 8 132 165 130 200 10 Tolerances A, B D ±0,8 ISO j6 Ø 28 mm ISO k6 < Ø 38 mm ISO m6 Ø 55 mm Tolerances F ISO h9 H -0,5 N ISO js6 C ±0,8 The table gives the main dimension in mm. For detailed drawings please see our web pages www.abb.com/motors&generators. ABB Motors and Generators | 9AKK105944 EN 02-2020 143 Dimension drawings Process performance IE3 aluminum motors, K-generation Foot-mounted motor IM1001, B3 and flange-mounted motor IM3001, B5 Motor size 80 80 90 100 112 132 160 180 200 225 225 250 250 Poles MB2, MC2 ME4 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2 4-6 2 4-6 D GA F 19 21.5 6 19 21.5 6 24 27 8 28 31 8 28 31 8 38 41 10 42 45 12 48 51.5 14 55 59 16 55 59 16 60 64 18 60 64 18 65 69 18 E L max A B B1 C HD K 40 265.5 125 100 50 193.5 10 40 293.5 125 100 50 193.5 10 50 331.5 140 125 56 217 10 60 432 160 140 63 237 12 60 431 190 140 70 260 12 80 487 216 140 178 89 298 12 110 681 254 210 254 108 370 15 110 726 279 241 279 121 405 15 110 821 318 267 305 133 532 18 110 850 356 286 311 149 553 18 140 880 356 286 311 149 553 18 140 884 406 311 349 168 601 22 140 884 406 311 349 168 601 22 M N P S 165 130 200 12 165 130 200 12 165 130 200 12 215 180 250 15 215 180 250 15 265 230 300 14.5 300 250 350 19 300 250 350 19 400 350 400 19 400 350 450 19 400 350 450 19 500 450 550 19 500 450 550 19 IMB14 (IM3601) Motor size M N P S 80 100 80 120 6 90 115 95 140 8 100 130 110 160 8 Motor size M N P S 112 130 110 160 8 132 165 130 200 10 Tolerances A, B D ±0,8 ISO j6 Ø 28 mm ISO k6 < Ø 38 mm ISO m6 Ø 55 mm Tolerances F ISO h9 H -0,5 N ISO js6 C ±0,8 The table gives the main dimension in mm. For detailed drawings please see our web pages www.abb.com/motors&generators. 144 9AKK105944 EN 02-2020 | ABB Motors and Generators Accessories Slide rails for motor sizes 160 to 280 E H B N 1 M Ymax. L Xmax. 3 5 F O D C 2 4 G A 1 Motor | 2 Rail | 3 Movable adjusting bolt | 4 Fixing bolt, motor | 5 Plate Motor size Type 1) Product code 3GZV103001- 160-180 200-225 250-280 TT180/12 -14 TT225/16 -15 TT280/20 -16 1) Smaller sizes on request. Weight A B C D E F G H L M N O Xmax Ymax (kg) 75 42 700 630 57 17 26 M12 120 M12 50 - 520 580 12.0 82 50 864 800 68 17 27 M16 140 M16 65 17 670 740 20.4 116 70 1072 1000 90 20 27 M18 150 M20 80 20 870 940 43.0 Each set includes two complete slide rails including screw for mounting the motor on the rails. Screws for mounting the rails on the foundation are not included. Slide rails are supplied with unmachined lower surfaces and should, prior to tightenng down, be supported in a suitable manner. ABB Motors and Generators | 9AKK105944 EN 02-2020 145 Motors in brief Aluminum motors, sizes 63 - 132 Motor size Stator and end shields Feet M3AA Material Paint colour shade Corrosion class Bearings D-end N-end Axially-locked bearings Inner bearing cover Bearing seal D-end N-end Lubrication Measuring nipples for condition monitoring of the bearings Rating plate Material Terminal box Material Cover screws material Connections Openings Fan Fan cover Stator winding Rotor winding Balancing Key ways Drain holes Terminals Cable glands Material Material Paint colour shade Corrosion class Material Insulation Winding protection Material External earthing bolt Enclosure Cooling method 63 71 80 90 100 112 132 Die-cast aluminum alloy Munsell blue 8B 4.5/3.25 C3 medium according IEO/EN 12944-5 Separate Integrated aluminum feet bolt on feet 6201-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6306-2Z/C3 6306-2Z/C3 6208-2Z/C3 6308-2Z/C3 (SM) 6201-2Z/C3 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6205-2Z/C3 6206-2Z/C3 ND-end re- Locked at D-end taining ring V-ring Labyrinth seal Permanent grease lubrication. Grease temperature range -40°C to +160°C Not included Aluminum Die-cast aluminum alloy, integrated to stator Zinc-electroplated steel 1xM16 2x(M20 + M20) 2x(M20 + M20) 2x(M20+M25) 6 terminals for connection with cable lugs (not included) Optional Glass-fiber reinforced polypropylene Polypropylene Munsell blue 8B 4.5/3.25 C3 medium according IEO/EN 12944-5 Copper Insulation class F Optional Die-cast aluminum Half key balancing Closed key way Without Drain holes with closable plastic plugs, open on delivery drain holes As option IP 55 IC 411 2x(M20+M25) 1) 2x(M40+M32+M12) 2) 1) S, SB, M, MA 2) SC, MC, SMA-SME 146 9AKK105944 EN 02-2020 | ABB Motors and Generators Motors in brief Aluminum motors, sizes 160 - 280 Motor size M3AA Stator and end shields Material Paint colour shade Corrosion class Feet Bearings D-end N-end Axially-locked bearings Inner bearing cover Bearing seal D-end N-end Lubrication Measuring nipples for condition monitoring of the bearings Rating plate Material Terminal box Material Connections Cover screws material Openings Fan Fan cover Stator winding Rotor winding Balancing Key ways Drain holes External earthing bolt Enclosure Cooling method Terminals Cable glands Material Material Paint colour shade Corrosion class Material Insulation Winding protection Material 160 180 200 225 Die-cast aluminum alloy Extruded aluminum alloy Munsell blue 8B 4.5/3.25 C3 medium according IEO/EN 12944-5 Separate aluminum feet Separate cast iron feet 6309-2Z/C3 6310-2Z/C3 6312-2Z/C3 6313-2Z/C3 6209-2Z/C3 6209-2Z/C3 6210-2Z/C3 6212-2Z/C3 Locked at D-end Axial seal Axial seal Permanently lubricated shielded bearings Not included 250 6315-2Z/C3 6213-2Z/C3 Aluminum Die-cast aluminum alloy, integrated Deep-drawn steel sheet, bolted to stator to stator Zinc-electroplated steel (2xM40+M16+(2xM40) 2xFL13, 2xM40 + 1xM16 Knock-out 6 terminals for connection with cable lugs (not included) Optional Glass-fiber reinforced polypropylene Steel Munsell blue 8B 4.5/3.25 C3 medium according IEO/EN 12944-5 Copper Insulation class F 3 PTC thermistors, 150 °C Die-cast aluminum Half key balancing Closed key way Drain holes with closable plastic plugs, open on delivery As option IP 55 IC411 280 6316/C3 6213/C3 Regreasable 2xFL21 ABB Motors and Generators | 9AKK105944 EN 02-2020 147 Total product offering Motors, generators and mechanical power transmission products with a complete portfolio of services IEC motors Low voltage motors High voltage induction and synchronous mo- tors Marine motors Motors for explosive atmospheres Motors for food and beverage Motors for variable speed drives Permanent magnet motors Synchronous reluctance motors Traction motors NEMA motors Low voltage motors High voltage induction and synchronous mo- tors Marine motors Motors for explosive atmospheres Motors for variable speed drives Permanent magnet motors Servomotors Washdown motors Generators Generators for wind turbines Generators for diesel and gas engine power plants Generators for steam and gas turbine power plants Generators for marine applications Generators for industrial applications Generators for traction applications Synchronous condensers for reactive power compensation Mechanical power transmission components, bearings, gearings Mounted bearings Enclosed gearing Mechanical drive components Couplings Sheaves and bushings Conveyor components Geared motor units Life cycle services 148 9AKK105944 EN 02-2020 | ABB Motors and Generators ABB's portfolio of drives Optimal solution for you Being able to rely on the continuous high performance and efficiency of your operations is something you want to take for granted. ABB variablefrequency drives are made with all this in mind, established upon more than 40 years of experience and backed by a broad range of life cycle services. ABB drives help you to optimize your processes and systems with state-of-the-art motor control technology, resulting in increased energy efficiency, better product quality, and reduced operating costs with higher output, less downtime, and reduced need for maintenance. All ABB drives are designed for easy selection, ordering, installation and use, and they offer integrated safety features, giving you more time to focus on what matters for you and your business. Our portfolio offers low-voltage AC and DC drives, medium-voltage AC drives, and motion control drives spanning the fractional-kilowatt to multimegawatt power level. There is a drive available for essentially every industry and application and for all types of motors, in environments ranging from water utility facilities to clean electrical rooms, and to harsh coal mines and windy offshore platforms to food and beverage production. This wide product range allows you to select the best-fitting drive solution, providing maximum reliability and efficiency for every need. ABB Motors and Generators | 9AKK105944 EN 02-2020 149 Contact us For more information and contact details: www.abb.com/motors&generators © Copyright 2020 ABB. All rights reserved. Specifications subject to change without notice. 9AKK105944 EN 02-2020Adobe PDF Library 10.0.1 Adobe InDesign CS6 (Windows)