File info: application/pdf · 150 pages · 21.44MB
Low voltage Process performance motors
Low voltage Process performance motors - MS Measuring Srl ...
Harmonized global standards and the increasing adoption of MEPS around the world are good news for all of us. However, it is important to remem-.150 pages
Extracted Text
CATALOG | FEBRUARY 2020
Low voltage Process performance motors
400 V 50 Hz, 460V 60 Hz
With expertise, and a comprehensive portfolio of products and life-cycle services, we help value-minded industrial customers improve their energy efficiency and productivity.
2
9AKK105944 EN 02-2020 | ABB Motors and Generators
Low voltage Process performance motors
Sizes 63 to 450, 0.09 to 1000 kW
4
General information
4
International motor efficiency standards
and regulations
7
Mounting arrangements
8
Cooling
9
Degrees of protection: IP code/IK code
10
Insulation
11
Voltage and frequency
12
Surface treatment
13
Variable speed drives with Process
performance motors
18
Cast iron motors
18
Ordering information
19
Rating plates
20
Technical data
56
Variant codes
63
Mechanical design
86
Dimension drawings
91
Accessories
99
Cast iron motors in brief
102
Motor construction
104
Aluminum motors
104
Ordering information
105
Rating plates
106
Technical data
123
Variant codes
128
Mechanical design
142
Dimension drawings
145
Accessories
146
Aluminum motors in brief
148
Total product offering
149
ABB's portfolio of drives
ABB Motors and Generators | 9AKK105944 EN 02-2020
3
International motor efficiency standards and regulations
Energy Efficiency Regulations, EE Regulations 2016, Canada DOE 10 CFR Part 431 (Integral Horsepower Motor Rule), US NOM-016-ENER-2016, Mexico
PRTE-145, Equador RTEE, Peru
Chile
Portaria interministerial No 553, Brazil
IRAM 62405, Argentina
BIS IS 12615, India
Singapore Indonesia SASO/IEC 60034-30, Saudi-Arabia
Regulation EC No 640/2009
MKE-2015-28, South-Korea
JIS 4213, Japan GB18613-2012, China CNS 14400, Taiwan Decree No. 21/2011/ND-CP, Vietnam
Greenhouse and Energy Minimum Standards Act, Australia
Energy efficiency and Conservation Authority New Zealand
Since the validation of IEC 60034-30:2008 and its refined version IEC 60034-30-1:2014, a worldwide energy efficiency classification system has existed for low voltage three-phase asynchronous motors. These international standards have been created to enable and increase the level of harmonization in efficiency regulations around the world and to also cover motors for explosive atmospheres. IEC 60034-30-1:2014 defines International Efficiency (IE) classes for single speed, three-phase, 50 Hz and 60 Hz induction motors. The efficiency levels defined in IEC 60034-30-1 are based on the test method specified in IEC 60034-2-1:2014. Both standards are part of an effort to unify motor testing procedures with CSA390-10 and IEEE 112 standards as well as efficiency and product labeling (IE) requirements to enable motor purchasers worldwide to easily recognize premium efficiency products. To promote transparency in the market, IEC 60034-30-1 states that both the efficiency class and efficiency value must be shown on the motor rating plate and in product documentation. The documentation must clearly indicate the efficiency testing method used as different methods can produce differing results. Minimum energy performance standards While the IEC as an international standardization organization sets guidelines for motor testing and efficiency classes, the organization does not regulate efficiency levels in countries. The biggest drivers for mandatory Minimum Energy Perfor-
mance Standard (MEPS) levels for electric motors are global climate change, government targets to curb CO2 emissions and rising electricity demand, especially in developing countries. The whole value chain, from manufacturer up to end user, must be aware of the legislation in order to meet local requirements, to save energy and reduce the carbon footprint. Harmonized global standards and the increasing adoption of MEPS around the world are good news for all of us. However, it is important to remember that harmonization is an ongoing process. Even though MEPS are already in effect in several regions and countries, they are evolving and differ in terms of scope and requirements. At the same time, more countries are planning to adopt their own MEPS regulations. A view of existing and coming MEPS regulations in the world can be seen on the World map above. To get the latest information please visit www.abb. com/motors&generators/energyefficiency.
4
9AKK105944 EN 02-2020 | ABB Motors and Generators
01 IE Classes - 4-pole motors.
IEC 60034-30-1:2014 This standard defines four International Efficiency (IE) classes for single speed electric motors that are rated according to IEC 60034-1 or IEC 60079-0 (explosive atmospheres) and designed for operation on sinusoidal voltage. �� IE4 = Super premium efficiency �� IE3 = Premium efficiency, identical to the table
in 10CFR431 (`NEMA Premium') in the USA and CSA C390-10:2015 for 60 Hz �� IE2 = High efficiency �� IE1 = Standard efficiency IEC 60034-30-1 covers the power range from 0.12 kW up to 1000 kW. Most of the different technical constructions of electric motors are covered as long as they are rated for direct on-line operation. The coverage of the standard includes: �� Single speed electric motors (single and threephase), 50 and 60 Hz �� 2, 4, 6 and 8 poles �� Rated output PN from 0.12 kW to 1000 kW �� Rated voltage UN above 50 V up to 1 kV �� Motors capable of continuous operation at their rated power with a temperature rise within the specified insulation temperature class �� Motors, marked with any ambient temperature within the range of -20 �C to +60 �C �� Motors, marked with an altitude up to 4000 m above sea level By comparing IEC 60034-30-1 to CSA C39010:2015 and "10CFR431 Subpart B � Electric motors", it can be seen that the efficiency limits and tables are well aligned and their major difference is in the scope of the output power where CSA and 10CFR431 have a maximum power of 500 hp. There are also some minor differences in the scope of excluded motors. Note: CFR is Code of Federal Regulations. The following motors are excluded from IEC 60034-30-1: �� Single-speed motors with 10 or more poles or multi-speed motors �� Motors completely integrated into a machine (for example pump, fan or compressor) that cannot be tested separately from the machine �� Brake motors, when the brake cannot be dismantled or separately fed
100
90
Efficiency %
80
IE4
IE3
70
IE2
IE1
60
50
0.12
0.37 0.75 1.5
3
7.5 15
37
Output kW
90 160
400
1000
__ 01 ABB and efficiency standards ABB determines efficiency values according to IEC 60034-2-1 using the low uncertainty method (i.e. summaration of losses), with additional load losses determined by the method of residual loss. It is good to mention and emphasize that the IEC 60034-2-1 test method, which is known as an indirect method, is technically equivalent to the test methods in the standards CSA 390-10 and IEEE 112 Method B leading to the equivalent losses and thus efficiency values. Both test methods can be used by ABB and shall be used for both Canada and the US where IEC 60034-2-1 is not recognized yet. As the world market leader, ABB offers the largest range of LV motors available. It has long advocated the need for efficiency in motors, and high efficiency products have formed the core of its portfolio for many years. The core of ABB's Process performance range is based on a full range of IE2 and IE3 motors - with many available from stock. We also supply IE4 motors for additional energy savings.
ABB Motors and Generators | 9AKK105944 EN 02-2020
5
Nominal efficiency limits defined in IEC 60034-30-1:2014 (reference values at 50 Hz, based on test methods specified in IEC 600342-1:2014).
Output
kW
0.12 0.18 0.20 0.25 0.37 0.40 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250 315 355 400 450 5001000
IE1 Standard efficiency
IE2 High efficiency
IE3 Premium efficiency
IE4 Super Premium efficiency
2 pole 45.0 52.8 54.6 58.2 63.9 64.9 69.0 72.1 75.0 77.2 79.7 81.5 83.1 84.7 86.0 87.6 88.7 89.3 89.9 90.7 91.2 91.7 92.1 92.7 93.0 93.3 93.5 93.8 94.0 94.0 94.0 94.0 94.0 94.0 94.0
4 pole 50.0 57.0 58.5 61.5 66.0 66.8 70.0 72.1 75.0 77.2 79.7 81.5 83.1 84.7 86.0 87.6 88.7 89.3 89.9 90.7 91.2 91.7 92.1 92.7 93.0 93.3 93.5 93.8 94.0 94.0 94.0 94.0 94.0 94.0 94.0
6 pole 38.3 45.5 47.6 52.1 59.7 61.1 65.8 70.0 72.9 75.2 77.7 79.7 81.4 93.1 84.7 86.4 87.7 88.6 89.2 90.2 90.8 91.4 91.9 92.6 92.9 93.3 93.5 93.8 94.0 94.0 94.0 94.0 94.0 94.0 94.0
8 pole 31.0 38.0 39.7 43.4 49.7 50.9 56.1 61.2 66.5 70.2 74.2 77.0 79.2 81.4 83.1 85.0 86.2 86.9 87.4 88.3 88.8 89.2 89.7 90.3 90.7 91.1 91.5 91.9 92.5 92.5 92.5 92.5 92.5 92.5 92.5
2 pole 4 pole
53.6 59.1 60.4 64.7 61.9 65.9 64.8 68.5 69.5 72.7 70.4 73.5 74.1 77.1 77.4 79.6 79.6 81.4 81.3 82.8 83.2 84.3 84.6 85.5 85.8 86.6 87.0 87.7 88.1 88.7 89.4 89.8 90.3 90.6 90.9 91.2 91.3 91.6 92.0 92.3 92.5 92.7 92.9 93.1 93.2 93.5 93.8 94.0 94.1 94.2 94.3 94.5 94.6 94.7 94.8 94.9 95.0 95.1 95.0 95.1 95.0 95.1 95.0 95.1 95.0 95.1 95.0 95.1 95.0 95.1
6 pole 50.6 56.6 58.2 61.6 67.6 68.8 73.1 75.9 78.1 79.8 81.8 83.3 84.6 86.0 87.2 88.7 89.7 90.4 90.9 91.7 92.2 92.7 93.1 93.7 94.0 94.3 94.6 94.8 95.0 95.0 95.0 95.0 95.0 95.0 95.0
8 pole 39.8 45.9 47.4 50.6 56.1 57.2 61.7 66.2 70.8 74.1 77.6 80.0 81.9 83.8 85.3 86.9 88.0 88.6 89.1 89.8 90.3 90.7 91.0 91.6 91.9 92.3 92.6 93.0 93.5 93.5 93.5 93.5 93.5 93.5 93.5
2 pole 60.8 65.9 67.2 69.7 73.8 74.6 77.8 80.7 82.7 84.2 85.9 87.1 88.1 89.2 90.1 91.2 91.9 92.5 92.7 93.3 93.7 94.0 94.3 94.7 95.0 95.2 95.4 95.6 95.8 95.8 95.8 95.8 95.8 95.8 95.8
4 pole 64.8 69.9 71.1 73.5 77.3 78.0 80.8 82.5 84.1 85.3 86.7 87.7 88.6 89.6 90.4 91.4 92.1 92.6 93.0 93.6 93.9 94.2 94.6 95.0 95.2 95,4 95.6 95.8 96.0 96.0 96.0 96.0 96.0 96.0 96.0
6 pole 57.7 63.9 65.4 68.6 73.5 74.4 77.2 78.9 81.0 82.5 84.3 85.6 86.8 88.0 89.1 90.3 91.2 91.7 92.2 92.9 93.3 93.7 94.1 94.6 94.9 95.1 95.4 95.6 95.8 95.8 95.8 95.8 95.8 95.8 95.8
8 pole 50.7 58.7 60.6 64.1 69.3 70.1 73.0 75.0 77.7 79.7 81.9 83.5 84.8 86.2 87.3 88.6 89.6 90.1 90.6 91.3 91.8 92.2 92.5 93.1 93.4 93.7 94.0 94.3 94.6 94.6 94.6 94.6 94.6 94.6 94.6
2 pole 66.5 70.8 71.9 74.3 78.1 78.9 81.5 83.5 85.2 86.5 88.0 89.1 90.0 90.9 91.7 92.6 93.3 93.7 94.0 94.5 94.8 95.0 95.3 95.6 95.8 96.0 96.2 96.3 96.5 96.5 96.5 96.5 96.5 96.5 96.5
4 pole 69.8 74.7 75.8 77.9 81.1 81.7 83.9 85.7 87.2 88.2 89,5 90.4 91.1 91.9 92.6 93.3 93.9 94.2 94.5 94.9 95.2 95.4 95.7 96.0 96.1 96.3 96.4 96.6 96.7 96.7 96.7 96.7 96.7 96.7 96.7
6
8
pole pole
64.9 62.3
70.1 67.2
71.4 68.4
74.1 70.8
78.0 74.3
78.7 74.9
80.9 77.0
82.7 78.4
84.5 80.8
85.9 82.6
87.4 84.5
88.6 85.9
89.5 87.1
90.5 88.3
91.3 89.3
92.3 90.4
92.9 91.2
93.4 91.7
93.7 92.1
94.2 92.7
94.5 93.1
94.8 93.4
95.1 93.7
95.4 94.2
95.6 94.4
95.8 94.7
96.0 94.9
96.2 95.1
96.3 95.4
96.5 95.4
96.6 95.4
96.6 95.4
96.6 95.4
96.6 95.4
96.6 95.4
6
9AKK105944 EN 02-2020 | ABB Motors and Generators
Mounting arrangements
Foot-mounted motor Code I / code II
IM B3 IM 1001
IM V5 IM 1011
IM V6 IM 1031
Flange-mounted motor, large flange Code I / code II
IM B6 IM 1051
IM B7 IM 1061
IM B8 IM 1071
Product code pos. 12 A: foot-mounted, term. box top R: foot-mounted, term. box RHS L: foot-mounted, term. box LHS
Product code pos. 12 B: flange mounted, large flange
IM B5 IM 3001
IM V1 IM 3011
IM V3 IM 3031
Flange-mounted motor, small flange Code I / code II
*) IM 3051
*) IM 3061
*) IM 3071
Product code pos. 12 C: flange mounted, small flange
IM B14 IM 3601
IM V18 IM 3611
IM V19 IM 3631
*) IM 3651
Foot- and flange-mounted motor with feet, large flange Code I / code II
IM B35 IM 2001
IM V15 IM 2011
IM V35 IM 2031
*) IM 2051
Foot- and flange-mounted motor with feet, small flange Code I / code II
*) IM 3661
*) IM 2061
*) IM 3671
*) IM 2071
Product code pos. 12 H: foot/flange-mounted, term. box top S: foot/flange-mounted, term. box RHS T: foot/flange-mounted, term. box LHS
Product code pos. 12 J: foot/flange-mounted, small flange
IM B34 IM 2101
IM V17 IM 2111
IM 2131
Foot-mounted motor, shaft with free extensions Code I / code II
IM 2151
IM 2161
IM 2171
Product code pos. 12
IM 1002
IM 1012
IM 1032
IM 1052
IM 1062
IM 1072
*) Not stated in IEC 60034-7. Note: If the motor is mounted shaft upwards, take measures to prevent water or any other liquid from running down the shaft into the motor.
ABB Motors and Generators | 9AKK105944 EN 02-2020
7
General information
Cooling
Designation system concerning methods of cooling refers to standard IEC 60034-6.
Explanation of the product code
International Cooling Circuit arrangement
Primary coolant
Method of movement of Secondary coolant primary coolant
IC
4
(A)
1
(A)
1
2
3
4
Position 1
0:
Free circulation (open circuit)
4:
Free circulatio (open circuit)
Method of movement of secondary coolant
6
5
Position 2
A:
For air (omitted for simplifi ed designation)
Position 3
0:
Free convection
1:
Self-circulation
6:
Machine-mounted independent component
Position 4
A:
For air (omitted for simplifi ed designation)
W:
For water
Position 5
0:
Free convection
1:
Self-circulation
6:
Machine-mounted independent component
8:
Relative displacement
8
9AKK105944 EN 02-2020 | ABB Motors and Generators
General information
Degrees of protection: IP code/IK code
Classification of degrees of protection provided by enclosures of rotating machines are refers to:
�� Standard IEC 60034-5 or EN 60529 for IP code �� Standard EN 50102 for IK code IP protection Protection of persons against getting in contact with (or approaching) live parts and against contact with moving parts inside the enclosure. Also protection of the machine against ingress of solid foreign objects. Protection of machines against the harmful effects due to the ingress of water.
Position 1
2:
Motors protected against solid objects greater than
12 mm
4:
Motors protected against solid objects greater than
1 mm
5:
Dust-protected motors
6:
Dust-tight motors
IK code Classification of degrees of protection provided by enclosure for motors against external mechanical impacts.
Position 1
Relation between IK code and impact energy:
IK code Impact energy/Joule
0:
Not protected according to EN 50102
01:
0.15
02:
0.2
03:
0.35
04: 0.5
05:
0.7
06:
1
07:
2
08: 5 (ABB Standard)
09:
10
10:
20
Position 2
3:
Motors protected against spraying water
4:
Motors protected against splashing water
5:
Motors protected against water jets
6:
Motors protected against heavy seas
ABB Motors and Generators | 9AKK105944 EN 02-2020
9
Insulation
01 Safety margins per thermal class.
ABB uses class F insulation, which, with temperature rise B, is the most common requirement among industry today. The use of class F insulation with class B temperature rise gives ABB products a 25 �C safety margin. This can be used to increase the loading for limited periods, to operate at higher ambient temperatures or altitudes, or with greater voltage and frequency tolerances. It can also be used to extend insulation. For instance, a 10 K temperature reduction will extend the insulation life. Thermal class 130 (B) �� Nominal ambient temperature 40 �C �� Max permissible temperature rise 80 K �� Hot spot temperature margin 10 K Thermal class 155 (F) �� Nominal ambient temperature 40 �C �� Max permissible temperature rise 105 K �� Hot spot temperature margin 10 K Thermal class 180 (H) �� Nominal ambient temperature 40 �C �� Max permissible temperature rise 125 K �� Hot spot temperature margin 10 K
�C
180 10
155 10
130
120
10
40
0
__ 01
80
105
125
40
40
40
B
F
H
130
155
180
10
9AKK105944 EN 02-2020 | ABB Motors and Generators
General information
Voltage and frequency
01 Voltage and frequency deviation in zones A and B.
The impact on temperature rise caused by voltage and frequency fluctuation is defined in IEC 600341. The standard divides the combinations into two zones, A and B. Zone A is the combination of voltage deviation of +/-5 % and frequency deviation of +/-2 %. Zone B is the combination of voltage deviation of +/-10 % and frequency deviation of +3/-5 %. This is illustrated in figure below. Motors are capable of supplying the rated torque in both zones A and B, but the temperature rise will be higher than at rated voltage and frequency. Motors can be run in zone B only for a short period of time.
Y 1.10
Key X axis Y axis 1 2 3
frequency p.u. voltage p.u. zone A zone B (outside zone A rating point
1 3
0.95 2
1.05 1.03
0.98
1.00
1.09 X
1.02
0.93 0.95
0.90
__ 01
ABB Motors and Generators | 9AKK105944 EN 02-2020
11
Surface treatment
The surface treatment categorization of ABB motors is based on the ISO 12944 standard. ISO 12994-5 divides paint system durability into three categories: low (L), medium (M), and high (H). Low durability corresponds to a lifetime of 2 - 5 years, medium to 5 � 15 years, and high durability to over 15 years. The durability range is not a guaranteed lifetime. Its purpose is to help the owner of the motor plan for appropriate maintenance intervals. More frequent maintenance may be required because of fading, chalking, contamination, wear and tear, or for other reasons.
ABB's standard surface treatment is corrosivity category C3, durability range M (which equal to medium corrosivity and medium durability). Special surface treatment is available in corrosivity categories C4 and C5-M, durability class M for both. In addition, surface treatment according to the NORSOK standard for offshore environments is available as an option. The standard ABB paint color for motors is Munsell blue 8B 4.5/3.25.
Corrosivity category C1, very low C2, low
C3, medium
C4, high
C5-I, very high (industrial) C5-M, very high (marine)
Outdoor atmospheres Not used
Atmospheres with low level pollution, mostly rural areas.
Urban and industrial atmospheres, moderate sulfur dioxide pollution. Coastal areas with low salinity. Industrial areas and coastal areas with moderate salinity.
Industrial areas and coastal areas with high humidity and aggressive atmosphere. Coastal and offshore areas with high salinity.
Indoor atmospheres
Use in ABB motors
Heated buildings with clean atmospheres
Not available
Unheated buildings where
Not available
condensation may occur, such
as depots and sports halls.
Production rooms with high Standard treatment humidity and some air pollution;
food processing plants,
laundries, breweries, dairies.
Chemical plants, swimming pools, coastal ship- and
Optional treatment for cast iron motors, variant code 115
boatyards.
Buildings or areas with nearly permanent condensation and high pollution.
Not available
Buildings or areas with nearly permanent condensation and high pollution.
Optional treatment for cast iron motors, variant code 754, 711
Atmospheric corrosivity categories and recommended environments.
12
9AKK105944 EN 02-2020 | ABB Motors and Generators
Variable-speed drives with process performance motors
Frequency converters provide significant benefits when used together with ABB process performance motors. The advantages include better process control and energy savings through regulation of motor speed, and smooth starting with reduced inrush current, reducing the stress on the equipment and supply network. By choosing an ABB motor�drive package, users can be confident that the motor and drive combination is optimized for their application; it is a working package with known performance, as the combination has been tested and verified. Process performance motors are designed for both DOL and variable-speed operation, and will, either as standard or by adding a few extras, be suitable for variable-speed operation. When selecting process performance motors for VSDs, the following points must be taken into consideration. The DriveSize selection software available at www.abb.com helps in selecting the optimal combination of motor, drive and supply transformer. Operating speed Process performance motors are designed to work over a wide speed range and also at speeds significantly higher than nominal. The maximum speeds can be found on motor rating plates or in DriveSize. In addition to motor speed, make sure that the maximum or critical speed of the entire application is not exceeded. Guideline maximum speed values for process performance motors are shown in Table 1.
Motor size 71-80 90-100 112-200 225-250 280 315 355 SM, ML, LKA 355 LKB 400 450
Maximum speed, r/min
2-pole motors 6000 6000 4500 3600 3600 3600 3600 3000 3600 3000
4-pole motors 4000 6000 4500 3600 2000 2200 2200 2200 2200 2200
Table 1. Guideline maximum speed values for process performance motors.
Ventilation When the motor is operating at low speeds, the cooling capacity of the fan decreases, which again reduces the motor's load capacity. A separate, constant-speed fan (variant codes 183, 422, 514) can be used to increase cooling capacity at low speed if required for loads with constant torque characteristics. Lubrication The lubrication interval of regreasable bearings depends on the running speed of the motor and the bearing temperature. Motors in frame size 280 and larger are delivered as standard with a lubrication plate in tabular format that states the relubrication intervals at different speeds and temperatures. A similar plate is optional for sizes 160�250 and can be ordered using variant code 795. Smaller motors usually have greased, sealed-for-life bearings. Please refer to the installation, operation and safety manual for further information on lubrication. Winding insulation To ensure that motors operate reliably, the effects of non-sinusoidal output voltages from the converter must be taken into consideration when selecting the correct insulation system for the motor and output filters for the converter. The insulation and filters must be selected according to Table 2.
Winding insulation and filters required
UN 500 V UN 600 V
Standard insulation
Standard insulation + dU/dt filters OR Special insulation (variant code 405)
UN 690 V
Special insulation (variant code 405) AND dU/dt-filters at converter output
600 V < UN 690 V cable length > 150 m
Special insulation (variant code 405)
Table 2. Selection of motor winding insulation and converter output filters
For more information on dU/dt filters, see the relevant ABB drives catalogs.
For other converters and cases where the guidelines shown in Table 2 cannot be applied, selection must be based on the voltages present at the motor terminals.
ABB Motors and Generators | 9AKK105944 EN 02-2020
13
01 Maximum allowed phase-to-phase voltage peaks at motor terminals, as a function pulse rise time.
Allowed phase-to-ground voltage peaks at motor terminals:
�� 1,300 V peak: standard insulation �� 1,800 V peak: special insulation, variant code
405 The maximum allowed phase-to-phase voltage peaks at the motor terminals as a function of pulse rise time are shown in Figure 01. The higher curve (special insulation) applies to motors with special winding insulation for frequency converter supply (variant code 405). Standard insulation applies to motors with a standard design.
Peak voltage ULL, kV
2,20 2,00 1,80 1,60 1,40 1,20 1,00 0,80
0,00
0,20
0,40
0,60 Rise time 10-90 %, �s
0,80
ABB Special Insul. ABB Standard Insul.
1,00
1,20
__ 01 Bearing currents Bearing voltages and currents must be avoided in all motors to ensure reliable operation of the entire application. Table 3 gives the selection rules depending on motor output power and frame size when used together with ABB converters; the same rules can also be applied as guidance when using ABB process performance motors with other converters.
Nominal power (PN and / or Frame size (IEC)
PN < 100 kW PN 100 kW OR IEC 315 Frame size IEC 355
PN 350 kW OR IEC 400 Frame size IEC 450
Precautionary measures
No action needed
Insulated non-drive end bearing
Insulated non-drive end bearing AND Common mode filter at the converter
Table 3. Precautionary measures to avoid bearing currents in variable speed drives.
Common mode filters Common mode filters are installed at the output of the frequency converter. These filters reduce common mode currents and so decrease the risk of bearing currents. Common mode filters do not significantly affect the phase of main voltages on motor terminals. For more information, see ABB drives catalogs. Insulated bearings ABB uses bearings with an insulated outer race or hybrid bearings with ceramic rolling elements. Insulated bearings at the non-drive end should be selected as indicated in Table 3. This solution can be ordered using variant code 701.
Earthing and cabling For motors with a nominal power above 30 kW, cables with a symmetrical concentric protective earth should be used across the system. The same type of cables are also recommended for motors with an output of 30 kW and below. Solutions for persistent bearing currents In very rare cases, bearing currents might still exist even if the measures specified above have been taken. For such installations, there are two advanced methods that would provide a remedy: either a shaft grounding bush, or insulated bearings at both ends. The shaft grounding bush is installed inside the motor to protect it from the environment and ensure good grounding of the shaft. The shaft grounding brush can be ordered using variant code 588. The second advanced solution is to mount insulated bearings at both ends. These can either be bearings with an insulated out race, or hybrid bearings with ceramic rolling elements. Insulated bearings at both ends can be ordered using variant code 702. Note that this variant cannot be combined with special drive-end bearing solutions, such as roller bearings or angular contact ball bearings. Electromagnetic compatibility (EMC) The high-frequency components in a variablespeed drive might cause electromagnetic interference with other equipment in the installation. To avoid this, certain measures should be taken. To meet EMC requirements, special EMC cables glands with a 360� connection to the concentric protective earth conductor should be used. Such cable glands can be used with variant code 704. Motor loadability with frequency converter drives The difference in the temperature rise of a motor run direct on line compared to the same motor run with a converter is influenced by factors such as the cooling effect of a shaft-mounted fan depending on the speed of the motor, increased losses due to harmonics generated by the converter and reduced flux above the field weakening point. The effects of all these factors are combined in the loadability curves. The loadability curves shown in Figures 02-05 are generic and give indicative guidelines for dimensioning standard low-voltage motors used with a frequency converter. The curves show the maximum continuous load torque as a function of frequency (speed), which results in the same temperature rise as opera-
14
9AKK105944 EN 02-2020 | ABB Motors and Generators
tion with the rated sinusoidal supply at nominal frequency and full rated load. Normally, process performance motors operate according to a class B temperature rise. For these motors, dimensioning should be according to the temperature rise B curve, or the motor can be slightly overloaded. In other words, it can be dimensioned according to the temperature rise F curve. However, if only a class F temperature rise with a sinusoidal supply is indicated for the motor in the technical data section, dimensioning must be done according to temperature rise curve B. If the motor is loaded according the temperature rise F curve, it will be necessary to check the temperature rise in other parts of the motor and ensure that the lubrication intervals and grease type are still appropriate.
ABB Motors and Generators | 9AKK105944 EN 02-2020
15
02 Loadability curves for ABB frequency converters with DTC control.
03 Loadability curves for other frequency converters.
04 Loadability curves for ABB frequency converters with DTC control.
05 Loadability curves for other frequency converters.
Curves are valid for a field weakening point of 50 Hz.
Temperature rise B
T/TN (%) 120
Separate cooling 100
80
Sizes 80-132
Sizes 160-450 60
40
Temperature rise F
T/TN (%) 120
Separate cooling
100
80
Sizes
80-132
Sizes 160-450 60
40
0 0
__ 02
20
40
60
80
100
Frequency (Hz)
0 0
__ 04
20
40
60
80
100
Frequency (Hz)
Temperature rise B
T/TN (%) 120
Separate cooling 100
Temperature rise F
T/TN (%) 120
Separate cooling
100
80
Sizes 80-132 60 Sizes 160-450
40
80
Sizes 80-132 60 Sizes 160-450
40
0 0
__ 03
20
40
60
80
100
Frequency (Hz)
0 0
__ 05
20
40
60
80
100
Frequency (Hz)
16
9AKK105944 EN 02-2020 | ABB Motors and Generators
Low voltage Process performance cast iron motors
18
Ordering information
19
Rating plates
20
Technical data IE2
37
Technical data IE3
50
Technical data IE4
56
Variant codes
63
Mechanical design
63
Motor frame and drain holes
66
Bearings
77
Terminal box
86
Dimension drawings
86
IE2 cast iron motors
88
IE3 cast iron motors
90
IE4 cast iron motors
91
Accessories
91
Built-in brake
94
Separate cooling
96
Silencer
97
Slide rails
99
Cast iron motors in brief
102
Motor construction
ABB Motors and Generators | 9AKK105944 EN 02-2020
17
Ordering information
Explanation of the product code
Motor type
Motor size
Product code
Mounting arrangement code, Variant codes Voltage and frequency code, Generation code
M3BP 160MLA 3GBP 161 410 - ADG
003, etc.
1 2 3 4 5 67
8 9 10 11 12 13 14
Positions 1 to 4
3GBP Totally enclosed fan cooled squirrel cage motor with cast iron frame
Positions 5 and 6
IEC size
07:
71
08:
80
09:
90
10:
100
12:
112
13:
132
16:
160
18:
180
IEC size
20:
200
22:
225
25:
250
28:
280
31:
315
35:
355
40:
400
45:
450
Position 7
Speed (Pole pairs)
1:
2 poles
2:
4 poles
3:
6 poles
4:
8 poles
5:
10 poles
6:
12 poles
7:
> 12 poles
8:
Two-speed motors for fan drive motors for constant
torque
9:
Multi-speed motors, two-speed
Positions 8 to 10 Serial number
Position 11 -(dash)
Position 12 (marked with black dot in data tables)
Mounting arrangement
A:
Foot-mounted, top-mounted terminal box
R:
Foot-mounted, terminal box RHS seen from D-end
L:
Foot-mounted, terminal box LHS seen from D-end
B:
Flange-mounted, large flange
C:
Flange-mounted, small flange (sizes 71 to 112)
H:
Foot- and flange-mounted, terminal box top-mount-
ed
Position 12 (marked with black dot in data tables)
J:
Foot- and flange-mounted, small flange with tapped
holes
S:
Foot- and flange-mounted, terminal box RHS seen
from D-end
T:
Foot- and flange-mounted, terminal box LHS seen
from D-end
V:
Flange-mounted, special flange
F:
Foot- and flange-mounted. Special flange
Position 13 (marked with black dot in data tables)
Voltage and frequency
Single-speed motors
B:
380 V 50 Hz
D:
400 V, 415 V, 690 VY 50 Hz
E:
500 V 50 Hz
F:
500 VY 50 Hz
S:
230 V, 400 VY, 415 VY 50 Hz
T:
660 V 50 Hz
U:
690 V 50 Hz
X:
Other rated voltage, connection or frequency, 690 V
maximum
Position 14 Generation code A, B, C...G...K: The product code must be, if needed, followed by variant codes.
Efficiency values are given according to IEC 600342-1; 2014 For detailed dimension drawings please see our web-pages `www.abb.com/motors&generators' or contact ABB.
18
9AKK105944 EN 02-2020 | ABB Motors and Generators
Rating plates
01 Rating plate example, motor size 100, IE2.
02 Rating plate example, motor size 160, K generation, IE3.
03 Rating plate example, motor size 315, L generation, IE3.
04 Rating plate example, motor size 315, IE4.
The motor's main rating plate shows the motor's performance values with various connections at nominal speed. The rating plate also shows the efficiency level (IE2, IE3, or IE4), year of manufacture, and the lowest nominal efficiency at 100, 75, and 50 % nominal load. The plate samples shown on this page present typical data rows. The actual content of the plate may vary according to your order and according to the motor's IE class.
__
__
01
03
__
__
02
04
ABB Motors and Generators | 9AKK105944 EN 02-2020
19
Technical data, 400 V 50 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3000 r/min = 2 poles
0.37
M3BP 71MA 2 3GBP071321-��B
0.55
M3BP 71MB 2 3GBP071322-��B
0.75
M3BP 80MB 2 3GBP081322-��B
1.1
M3BP 80MC 2 3GBP081323-��B
1.5
M3BP 90SLB 2 3GBP091322-��B
2.2
M3BP 90SLC 2 3GBP091323-��B
3
M3BP 100LB 2 3GBP101322-��B
4
M3BP 112MB 2 3GBP111322-��B
5.5
M3BP 132SMB 2 3GBP131322-��B
7.5
M3BP 132SMC 2 3GBP131324-��B
11
M3BP 160MLA 2 3GBP161410-��G
15
M3BP 160MLB 2 3GBP161420-��G
18.5
M3BP 160MLC 2 3GBP161430-��G
22
M3BP 180MLA 2 3GBP181410-��G
30
M3BP 200MLA 2 3GBP201410-��G
37
M3BP 200MLB 2 3GBP201420-��G
45
M3BP 225SMA 2 3GBP221210-��G
55
M3BP 250SMA 2 3GBP251210-��G
75
M3BP 280SMA 2 3GBP281210-��N
90
M3BP 280SMB 2 3GBP281220-��N
110
M3BP 315SA 2 3GBP311110-��N
132
M3BP 315SMA 2 3GBP311210-��N
160
M3BP 315SMB 2 3GBP311220-��N
200 1) M3BP 315MLA 2 3GBP311410-��G
250 1) M3BP 355SMA 2 3GBP351210-��G
315 1) M3BP 355SMB 2 3GBP351220-��G
355 1) M3BP 355SMC 2 3GBP351230-��G
400 1) M3BP 355MLA 2 3GBP351410-��G
450 1) M3BP 355MLB 2 3GBP351420-��G
500 1) M3BP 355LKA 2 3GBP351810-��G
560 1) M3BP 400LA 2 3GBP401510-��G
560 2) M3BP 400LKA 2 3GBP401810-��G
560 1) M3BP 355LKB 2 3GBP351820-��G
630 2) M3BP 400LB 2 3GBP401520-��G
630 2) M3BP 400LKB 2 3GBP401820-��G
710 2) M3BP 400LC 2 3GBP401530-��G
710 2) M3BP 400LKC 2 3GBP401830-��G
800 2)3) M3BP 450LA 2 3GBP451510-��G
900 2)3) M3BP 450LB 2 3GBP451520-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
2768 2813 2895 2870 2900 2885 2925 2895 2865 2890 2938 2934 2932 2952 2956 2959 2961 2967 2972 2970 2978 2976 2975 2980 2984 2980 2984 2982 2983 2982 2988 2988 2983 2987 2987 2987 2987 2990 2990
400 V 50 Hz 74.8 75.4 77.8 78.3 80.6 79.6 81.8 81.7 82.2 82.9 83.2 85.5 85.2 84.9 86.1 87.0 87.7 88.4 88.2 88.8 90.6 91.5 91.5 92.4 92.0 93.1 92.2 92.7 93.1 93.5 93.4 93.7 93.6 93.9 94.1 94.4 93.8 94.0 94.1 94.3 94.3 94.2 94.6 94.6 94.8 94.9 95.7 95.7 95.7 95.5 95.7 95.6 95.7 95.7 96.5 96.3 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 97.0 97.0 96.5 96.2 96.5 96.2 96.5 96.3 96.5 96.3 96.5 96.2 96.5 96.2
72.4 76.0 75.6 78.9 81.3 84.3 82.7 86.6 87.7 87.6 91.1 92.2 93.1 92.2 92.8 92.9 93.1 93.8 93.4 93.8 93.3 93.8 94.4 94.9 94.5 94.9 94.9 95.6 95.7 96.0 95.7 95.7 96.5 95.6 95.6 95.7 95.7 95.4 95.5
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.78 0.89 4.5 1.27 2.2 2.3 0.00039
0.79 1.29 4.3 1.86 2.4 2.5 0.00051
0.74 1.8 7.7 2.4
4.2 4.2 0.001
0.80 2.44 7.5 3.63 3.7 4.6 0.0012
0.87 3.26 7.5 4.9
2.5 2.6 0.00254
0.88 4.2 6.8 7.2
1.9 2.5 0.0028
0.87 5.75 9.1 9.7
3.1 3.5 0.00528
0.89 7.52 8.1 13.1 2.9 3.2 0.00575
0.86 10 7.0 18.3 2.6 2.7 0.0128
0.89 13.7 7.3 24.9 2.6 3.6 0.0136
0.90 19.2 7.5 35.7 2.4 3.1 0.044
0.90 26 7.5 48.8 2.5 3.3 0.053
0.92 31.5 7.5 60.2 2.9 3.4 0.063
0.87 39.6 7.7 71.1 2.8 3.3 0.076
0.90 51.6 7.7 96.9 2.7 3.1 0.178
0.90 63.5 8.2 119 3.0 3.3 0.196
0.88 78.8 6.7 145 2.5 2.5 0.244
0.88 95.8 6.8 177
2.2 2.7 0.507
0.89 128 7.8 241 2.5 3.0 0.61
0.91 149 7.5 289 2.7 3.1 0.73
0.90 187 7.6 353 2.4 3.1 0.95
0.90 223 7.3 423 2.5 3.0 1.1
0.90 268 7.3 513 2.4 3.0 1.25
0.90 335 7.7 640 2.6 3.0 2.1
0.89 423 7.7 800 2.1 3.3 3
0.89 531 7.0 1009 2.1 3.0 3.4
0.88 603 7.2 1136 2.2 3.0 3.6
0.88 677 7.1 1280 2.3 2.9 4.1
0.90 743 7.9 1440 2.2 2.9 4.3
0.90 827 7.5 1601 2.0 3.9 4.8
0.89 934 7.8 1789 2.5 3.7 7.9
0.89 934 7.8 1789 2.5 3.7 7.9
0.90 925 8.0 1792 2.2 4.1 5.2
0.89 1049 7.6 2014 2.6 3.7 8.2
0.89 1049 7.6 2014 2.6 3.7 8.2
0.89 1178 7.2 2270 2.6 3.4 9.3
0.89 1178 7.2 2270 2.6 3.4 9.3
0.87 1362 7.8 2555 1.3 3.4 12.2
0.87 1534 7.6 2874 1.5 3.1 13.5
Weight kg
Sound
pressure
Level LPA dB
11
58
11
56
16
57
18
60
24
69
25
64
36
68
37
70
68
70
70
70
127
69
141
69
170
69
190 69
283 72
298 72
347 74
405 75
540 77
590 77
770 78
865 78
925 78
1190 78
1600 83
1680 83
1750 83
2000 83
2080 83
2320 83
2950 82
2950 82
2460 83
3050 82
3050 82
3300 82
3300 82
4000
4200
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
20
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3000 r/min = 2 poles
22
M3BP 160MLD 2 3GBP161440-��G
27
M3BP 160MLE 2 3GBP161450-��G
30
M3BP 180MLB 2 3GBP181420-��G
45
3) M3BP 200MLC 2 3GBP201430-��G
55
3) M3BP 200MLD 2 3GBP201440-��G
55
M3BP 225SMB 2 3GBP221220-��G
75
3) M3BP 225SMC 2 3GBP221230-��G
75
M3BP 250SMB 2 3GBP251220-��G
80
3) M3BP 225SMD 2 3GBP221240-��G
90
3) M3BP 250SMC 2 3GBP251230-��G
110 1) M3BP 280SMC 2 3GBP281230-��G
132 1) M3BP 280MLA 2 3GBP281410-��G
160 1) M3BP 280MLB 2 3GBP281420-��G
250 1) M3BP 315LKA 2 3GBP311810-��G
315 1)3) M3BP 315LKC 2 3GBP311830-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
2933 2939 2950 2957 2953 2961 2969 2970 2964 2971 2978 2977 2976 2980 2981
400 V 50 Hz 91.7 92.8 92.2 93.1 92.7 93.5 93.3 93.8 93.8 94.4 93.9 94.3 94.4 94.6 94.5 94.8 94.4 94.8 94.9 95.2 95.1 95.1 95.3 95.3 95.5 95.7 95.7 95.7 95.7 95.7
92.8 93.0 93.3 93.2 94.3 93.6 94.0 94.4 94.3 94.8 94.5 94.8 95.3 95.2 95.4
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.90 38 8.1 71.6 3.2 3.6 0.063
0.90 46.4 8.8 87.7 3.4 3.8 0.072
0.88 53 7.9 97.1 2.8 3.3 0.092
0.88 79.1 7.9 145 3.1 3.3 0.196
0.89 95 7.8 177
2.9 3.3 0.217
0.88 96 6.5 177
2.4 2.5 0.274
0.84 136 7.4 241 3.2 3.1 0.309
0.89 128 7.6 241 2.8 3.1 0.583
0.87 140 7.3 257 3.0 2.8 0.329
0.89 153 7.6 289 2.5 3.1 0.644
0.90 186 7.9 352 2.4 3.0 1.15
0.90 221 7.5 423 2.5 3.0 1.4
0.91 265 7.6 513 2.8 3.0 1.55
0.89 423 7.6 801 2.8 2.9 2.65
0.89 533 8.8 1009 3.2 3.2 3.3
Weight kg
Sound
pressure
Level LPA dB
170
69
184 69
208 69
298 72
314 72
369 74
396 74
451 75
410 74
487 75
725 77
840 81
890 81
1440 78
1630 78
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
ABB Motors and Generators | 9AKK105944 EN 02-2020
21
Technical data, 400 V 50 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1500 r/min = 4 poles
0.25
M3BP 71MA 4 3GBP072321-��B
0.37
M3BP 71MB 4 3GBP072322-��B
0.55
M3BP 80MA 4 3GBP082321-��B
0.75
M3BP 80MD 4 3GBP082324-��B
1.1
M3BP 90SLB 4 3GBP092322-��B
1.5
M3BP 90SLD 4 3GBP092325-��B
2.2
M3BP 100LC 4 3GBP102323-��B
3
M3BP 100LD 4 3GBP102324-��B
4
M3BP 112MB 4 3GBP112322-��B
5.5
M3BP 132SMB 4 3GBP132322-��B
7.5
M3BP 132SMC 4 3GBP132323-��B
11
M3BP 160MLA 4 3GBP162410-��G
15
M3BP 160MLB 4 3GBP162420-��G
18.5
M3BP 180MLA 4 3GBP182410-��G
22
M3BP 180MLB 4 3GBP182420-��G
30
M3BP 200MLA 4 3GBP202410-��G
37
M3BP 225SMA 4 3GBP222210-��G
45
M3BP 225SMB 4 3GBP222220-��G
55
M3BP 250SMA 4 3GBP252210-��G
75
M3BP 280SMA 4 3GBP282210-��N
90
M3BP 280SMB 4 3GBP282220-��N
110
M3BP 315SA 4 3GBP312110-��N
132
M3BP 315SMA 4 3GBP312210-��N
160
M3BP 315SMB 4 3GBP312220-��N
200
M3BP 315MLA 4 3GBP312410-��G
250
M3BP 355SMA 4 3GBP352210-��G
315
M3BP 355SMB 4 3GBP352220-��G
355
M3BP 355SMC 4 3GBP352230-��G
400
M3BP 355MLA 4 3GBP352410-��G
450
M3BP 355MLB 4 3GBP352420-��G
500
M3BP 355LKA 4 3GBP352810-��G
560 3) M3BP 355LKB 4 3GBP352820-��G
560 3) M3BP 400LA 4 3GBP402510-��G
560 3) M3BP 400LKA 4 3GBP402810-��G
630
M3BP 400LB 4 3GBP402520-��G
630
M3BP 400LKB 4 3GBP402820-��G
710 3) M3BP 400LC 4 3GBP402530-��G
710 3) M3BP 400LKC 4 3GBP402830-��G
800
M3BP 450LA 4 3GBP452510-��G
900
M3BP 450LB 4 3GBP452520-��G
1000 3) M3BP 450LC 4 3GBP452530-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1365 1380 1415 1430 1435 1430 1450 1450 1440 1460 1450 1466 1470 1477 1475 1480 1479 1480 1480 1481 1481 1484 1482 1483 1486 1488 1488 1487 1489 1490 1490 1490 1491 1491 1491 1491 1491 1491 1491 1492 1491
400 V 50 Hz 68.5 70.9 71.6 73.8 70.0 71.3 81.0 81.0 81.4 82.0 84.3 85.1 85.9 85.1 86.8 86.9 86.6 87.2 89.0 89.8 89.3 90.1 90.4 91.6 91.4 92.3 91.9 92.8 92.3 93.3 93.2 94.0 93.4 93.9 93.9 94.3 94.4 94.9 94.0 94.3 94.2 94.2 94.5 94.9 94.7 95.1 94.9 95.2 95.6 95.6 95.9 96.0 95.9 96.2 95.9 96.2 96.0 96.0 96.0 96.1 96.7 96.7 96.9 96.9 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.5 96.7 96.7
69.8 74.0 68.7 78.2 80.1 83.9 83.4 85.3 86.8 88.9 90.0 91.3 92.2 92.6 93.2 93.7 93.4 93.9 94.6 93.8 94.3 94.7 95.0 94.9 95.3 95.5 95.8 95.9 95.5 95.6 96.1 96.5 96.1 96.1 96.1 96.1 96.2 96.2 96.1 96.0 96.1
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.81 0.63 3.5 1.74 1.9 2.0 0.00074
0.83 0.87 4.6 2.5
1.6 2.1 0.00088
0.80 1.45 4.5 3.7
2.0 2.5 0.00144
0.73 1.82 6.3 5
3.3 3.6 0.002
0.80 2.36 6.5 7.3
2.4 3.4 0.0044
0.83 3
6.3 10
2.7 3.4 0.0053
0.78 4.6 7.7 14.5 2.7 4.1 0.0095
0.79 6.1 7.7 19.8 2.9 3.6 0.011
0.82 7.94 7.0 26.5 2.5 2.9 0.0125
0.80 10.8 7.1 36
2.2 3.2 0.0328
0.81 14.5 7.2 49.4 2.5 3.5 0.0366
0.84 20.9 6.8 71.6 2.2 2.8 0.081
0.83 28.5 7.1 97.4 2.6 3.0 0.099
0.84 34.5 7.2 119 2.6 2.9 0.166
0.84 40.9 7.3 142 2.6 3.0 0.195
0.84 55.3 7.4 193 2.8 3.0 0.309
0.84 68 7.1 238 2.6 2.9 0.356
0.85 81.3 7.5 290 2.8 3.2 0.44
0.85 98.9 7.0 354 2.6 2.9 0.765
0.83 137 7.7 483 3.3 3.4 0.91
0.85 161 7.5 580 2.9 3.3 1.13
0.86 195 6.8 707 2.7 2.9 1.5
0.88 229 6.7 850 2.4 2.7 2
0.86 282 7.0 1030 2.6 2.9 2.2
0.86 351 7.2 1285 2.5 2.9 3.5
0.85 442 7.1 1604 2.3 2.7 5.9
0.86 550 7.3 2021 2.3 2.8 6.9
0.87 614 6.8 2279 2.4 2.7 7.2
0.85 705 6.8 2565 2.3 2.6 8.4
0.86 780 6.9 2884 2.3 2.9 8.4
0.86 865 6.8 3204 2.0 3.0 10
0.85 981 7.2 3588 2.6 2.7 10.6
0.85 982 7.4 3586 2.4 2.8 15
0.85 982 7.4 3586 2.4 2.8 15
0.87 1077 7.6 4034 2.2 2.9 16
0.87 1077 7.6 4034 2.2 2.9 16
0.86 1227 7.6 4547 2.4 3.0 17
0.86 1227 7.6 4547 2.4 3.0 17
0.86 1396 7.0 5121 1.3 2.8 23
0.86 1573 7.0 5761 1.3 2.8 25
0.86 1724 6.8 6404 1.3 2.7 30
Weight kg
Sound
pressure
Level LPA dB
10
45
11
45
15
45
17
50
25
50
27
56
36
56
38
58
44
59
70
67
73
64
135 62
165 62
205 62
222 62
291 63
324 66
356 66
414 67
540 70
610 70
740 68
900 68
940 68
1160 70
1610 74
1780 74
1820 78
2140 78
2140 78
2500 78
2600 78
3200 78
3200 78
3300 78
3300 78
3400 78
3400 78
4050 85
4350 85
4700 85
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
22
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1500 r/min = 4 poles
18.5
M3BP 160MLC 4 3GBP162430-��G
22
3) M3BP 160MLD 4 3GBP162440-��G
30
3) M3BP 180MLC 4 3GBP182430-��G
37
M3BP 200MLB 4 3GBP202420-��G
45
3) M3BP 200MLC 4 3GBP202430-��G
55
M3BP 225SMC 4 3GBP222230-��G
64
M3BP 225SMD 4 3GBP222240-��G
75
3) M3BP 250SMB 4 3GBP252220-��G
90
3) M3BP 250SMC 4 3GBP252230-��G
110
M3BP 280SMC 4 3GBP282230-��G
132
M3BP 280MLA 4 3GBP282410-��G
160
M3BP 280MLB 4 3GBP282420-��G
250
M3BP 315LKA 4 3GBP312810-��G
280
M3BP 315LKB 4 3GBP312820-��G
315
M3BP 315LKC 4 3GBP312830-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1469 1466 1474 1479 1479 1478 1480 1478 1478 1485 1483 1484 1487 1487 1488
400 V 50 Hz 91.4 91.9 91.6 92.4 92.3 92.8 93.4 94.4 93.6 94.4 94.0 94.6 94.2 94.6 94.4 95.1 94.6 95.3 95.1 95.4 95.3 95.5 95.6 95.9 95.7 95.8 95.8 95.9 95.8 95.9
91.7 92.5 92.7 94.4 94.2 94.4 94.1 94.8 95.0 95.1 95.1 95.7 95.2 95.4 95.3
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.84 34.7 7.6 120 3.0 3.2 0.11
0.86 40.8 6.9 143 2.5 2.9 0.125
0.83 56.5 7.3 194 2.7 2.9 0.217
0.85 67.2 7.1 238 2.6 2.9 0.343
0.83 83.6 7.5 290 2.9 3.2 0.366
0.85 99.3 7.4 355 2.9 3.1 0.474
0.85 115 8.0 412 3.3 3.3 0.542
0.85 134 7.3 484 2.8 3.1 0.866
0.84 163 7.4 581 3.1 3.3 0.941
0.86 193 7.6 707 3.0 3.0 1.85
0.86 232 7.0 849 2.7 2.8 2.3
0.85 284 7.4 1029 2.9 2.9 2.5
0.85 443 7.4 1605 2.5 2.9 4.4
0.87 491 7.6 1798 2.6 3.0 5
0.86 559 7.8 2021 2.6 3.2 5.5
Weight kg
Sound
pressure
Level LPA dB
173
62
187
62
235 62
307 63
319
63
370 66
399 66
450 67
478 67
725 68
840 75
890 75
1410 78
1520 78
1600 78
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
ABB Motors and Generators | 9AKK105944 EN 02-2020
23
Technical data, 400 V 50 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1000 r/min = 6 poles
0.18
M3BP 71MA 6 3GBP073321-��B
0.25
M3BP 71MB 6 3GBP073322-��B
0.37
M3BP 80MA 6 3GBP083321-��B
0.55
M3BP 80MB 6 3GBP083322-��B
0.75
M3BP 90SLC 6 3GBP093323-��B
1.1
M3BP 90SLE 6 3GBP093324-��B
1.5
M3BP 100L 6 3GBP103322-��B
2.2
M3BP 112MB 6 3GBP113322-��B
3
M3BP 132SMB 6 3GBP133321-��B
4
M3BP 132SMC 6 3GBP133322-��B
5.5
M3BP 132SMF 6 3GBP133324-��B
7.5
M3BP 160MLA 6 3GBP163410-��G
11
M3BP 160MLB 6 3GBP163420-��G
15
M3BP 180MLA 6 3GBP183410-��G
18.5
M3BP 200MLA 6 3GBP203410-��G
22
M3BP 200MLB 6 3GBP203420-��G
30
M3BP 225SMA 6 3GBP223210-��G
37
M3BP 250SMA 6 3GBP253210-��G
45
M3BP 280SMA 6 3GBP283210-��N
55
M3BP 280SMB 6 3GBP283220-��N
75
M3BP 315SA 6 3GBP313110-��N
90
M3BP 315SMA 6 3GBP313210-��N
110
M3BP 315SMB 6 3GBP313220-��N
132
M3BP 315MLA 6 3GBP313410-��G
160
M3BP 355SMA 6 3GBP353210-��G
200
M3BP 355SMB 6 3GBP353220-��G
250
M3BP 355SMC 6 3GBP353230-��G
315
M3BP 355MLB 6 3GBP353420-��G
355
M3BP 355LKA 6 3GBP353810-��G
400 3) M3BP 355LKB 6 3GBP353820-��G
400
M3BP 400LA 6 3GBP403510-��G
400
M3BP 400LKA 6 3GBP403810-��G
450
M3BP 400LB 6 3GBP403520-��G
450
M3BP 400LKB 6 3GBP403820-��G
500
M3BP 400LC 6 3GBP403530-��G
500
M3BP 400LKC 6 3GBP403830-��G
560
M3BP 400LD 6 3GBP403540-��G
560
M3BP 400LKD 6 3GBP403840-��G
630
M3BP 450LA 6 3GBP453510-��G
710
M3BP 450LB 6 3GBP453520-��G
800 3) M3BP 450LC 6 3GBP453530-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 900 63.7 63.8 915 67.2 65.5 925 67.6 66.5 920 73.1 74.2 960 76.3 74.7 930 78.2 78.7 950 81.3 82.1 950 82.5 83.7 975 85.3 84.2 960 84.9 85.4 965 86.1 86.6 975 88.5 89.9 972 89.3 90.6 977 90.2 90.6 988 91.6 92.2 987 92.0 92.9 986 92.6 93.3 989 93.1 93.8 989 92.7 93.0 990 93.1 93.7 989 93.7 94.1 990 94.0 94.3 990 94.3 94.5 991 95.0 95.0 991 95.3 95.4 993 95.4 95.6 993 95.7 95.8 992 95.7 96.0 992 95.7 95.9 992 96.0 96.0 993 95.8 95.8 993 95.8 95.8 994 95.8 95.8 994 95.8 95.8 993 95.8 95.6 993 95.8 95.6 993 96.6 96.6 993 96.6 96.6 994 95.8 95.9 995 96.6 96.7 995 96.6 96.6
59.0 59.5 60.9 71.9 69.5 76.5 80.7 81.6 81.2 83.9 85.5 89.7 90.5 90.0 91.7 92.7 92.8 93.4 92.4 93.4 93.9 93.7 94.0 94.6 94.9 95.2 95.4 95.5 95.4 95.5 95.1 95.1 95.2 95.2 95.2 95.2 96.0 96.0 95.3 96.1 96.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.71 0.57 3.1 1.91 2.0 2.1 0.00089
0.69 0.77 3.7 2.6
2.6 2.7 0.0011
0.69 1.09 4.1 3.8
2.4 2.5 0.0019
0.71 1.51 3.8 5.7
1.8 2.2 0.00239
0.58 2.3 4.5 7.4
2.4 3.1 0.00491
0.66 3.0 4.0 11.2 1.9 2.3 0.0054
0.69 3.7 4.3 15
1.5 2.7 0.00873
0.69 5.5 4.4 22.1 1.7 2.3 0.0125
0.63 8.0 5.5 29.4 1.8 2.9 0.0334
0.68 10 5.0 39.7 2.0 2.6 0.0334
0.71 12.9 5.1 54.4 2.0 2.3 0.0487
0.79 15.4 7.4 73.4 1.7 3.2 0.087
0.79 22.5 7.5 108 1.9 2.9 0.114
0.76 31.5 5.8 146 1.8 2.7 0.168
0.80 36.4 6.7 178 2.3 2.9 0.382
0.82 42 6.6 212 2.2 2.8 0.448
0.83 56.2 7.0 290 2.6 2.9 0.663
0.82 69.9 6.8 357 2.4 2.7 1.13
0.82 85.2 6.8 434 2.6 2.7 1.36
0.82 102 7.5 530 3.0 3.3 1.8
0.84 138 7.0 724 2.6 2.6 2.6
0.82 169 7.0 868 2.7 2.9 2.8
0.82 205 7.3 1061 2.9 3.0 3.5
0.83 201 7.4 1059 2.5 2.9 4.9
0.83 240 7.5 1271 2.7 3.0 5.8
0.83 291 7.0 1538 2.0 2.6 7.9
0.82 460 7.4 2404 2.6 2.9 11.3
0.83 570 7.0 3032 2.5 2.7 13.5
0.81 658 7.6 3417 2.7 2.9 15.5
0.83 724 7.2 3850 2.6 2.6 16.5
0.82 731 7.1 3846 2.3 2.7 17
0.82 731 7.1 3846 2.3 2.7 17
0.82 819 7.4 4323 2.4 2.8 20.5
0.82 819 7.4 4323 2.4 2.8 20.5
0.83 891 7.2 4809 2.5 2.7 22
0.83 891 7.2 4809 2.5 2.7 22
0.85 984 7.4 5386 2.4 2.8 24
0.85 984 7.4 5386 2.4 2.8 24
0.84 1127 6.5 6053 1.1 2.5 31
0.85 1244 7.0 6814 1.3 2.5 37
0.84 1415 7.2 7677 1.3 2.7 41
Weight kg
Sound
pressure
Level LPA dB
10
42
12
42
15
47
17
47
25
44
28
44
37
49
44
66
69
57
69
57
86
57
134 59
172
59
207 59
269 63
291 63
349 63
395 63
525 64
600 64
775 66
855 70
960 70
1000 70
1150 68
1520 75
1820 75
2180 75
2500 75
2600 75
2900 76
2900 76
3150 76
3150 76
3300 76
3300 76
3400 77
3400 77
4150 81
4500 81
4800 81
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
24
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1000 r/min = 6 poles
15
M3BP 160MLC 6 3GBP163430-��G
18.5
M3BP 180MLB 6 3GBP183420-��G
30
3) M3BP 200MLC 6 3GBP203430-��G
37
M3BP 225SMB 6 3GBP223220-��G
45
3) M3BP 225SMC 6 3GBP223230-��G
45
M3BP 250SMB 6 3GBP253220-��G
55
M3BP 250SMC 6 3GBP253230-��G
75
M3BP 280SMC 6 3GBP283230-��G
90
M3BP 280MLA 6 3GBP283410-��G
110
M3BP 280MLB 6 3GBP283420-��G
160
M3BP 315LKA 6 3GBP313810-��G
180
M3BP 315LKB 6 3GBP313820-��G
200
M3BP 315LKC 6 3GBP313830-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 971 89.7 90.5 90.2 975 90.7 92.0 92.0 985 92.0 93.1 92.8 985 93.1 94.0 94.0 984 92.7 93.3 93.3 989 93.4 94.1 93.9 988 93.2 93.7 93.6 990 94.2 94.7 94.5 990 94.1 94.3 93.7 990 94.5 94.8 94.4 992 95.3 95.3 94.7 992 95.3 95.4 94.8 989 95.4 95.6 95.3
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.77 31.3 7.3 147 1.8 3.6 0.131
0.79 37.2 5.8 181 1.7 2.7 0.198
0.83 56.7 6.9 290 2.3 2.8 0.531
0.83 69.1 6.6 358 2.3 2.6 0.821
0.83 84.4 6.4 436 2.3 2.6 0.821
0.83 83.7 7.0 434 2.5 2.7 1.37
0.84 101 7.1 531 2.6 2.8 1.5
0.84 137 7.3 723 2.8 2.7 2.85
0.81 170 7.1 868 2.4 2.5 3.1
0.82 205 7.5 1061 2.7 2.6 4.1
0.83 291 7.5 1540 2.6 2.8 7.3
0.83 328 7.4 1732 2.6 2.8 8.3
0.85 360 6.8 1931 2.5 2.6 9.2
Weight kg
Sound
pressure
Level LPA dB
185 59
221
59
318 63
393 63
393 63
441 63
468 63
725 66
840 70
890 70
1410 74
1520 74
1600 74
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
ABB Motors and Generators | 9AKK105944 EN 02-2020
25
Technical data, 400 V 50 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
750 r/min = 8 poles
0.09
M3BP 71MA 8 3GBP074101-��B
0.12
M3BP 71MB 8 3GBP074102-��B
0.18
M3BP 80MA 8 3GBP084101-��B
0.25
M3BP 80MB 8 3GBP084102-��B
0.37
M3BP 90SLB 8 3GBP094102-��B
0.55
M3BP 90SLC 8 3GBP094103-��B
0.75
M3BP 100LA 8 3GBP104101-��B
1.1
M3BP 100LB 8 3GBP104102-��B
1.5
M3BP 112M 8 3GBP114101-��B
2.2
M3BP 132SMA 8 3GBP134101-��B
3
4) M3BP 132SMB 8 3GBP134102-��B
4
M3BP 160MLA 8 3GBP164410-��G
5.5
M3BP 160MLB 8 3GBP164420-��G
7.5
M3BP 160MLC 8 3GBP164430-��G
11
M3BP 180MLA 8 3GBP184410-��G
15
M3BP 200MLA 8 3GBP204410-��G
18.5
M3BP 225SMA 8 3GBP224210-��G
22
M3BP 225SMB 8 3GBP224220-��G
30
M3BP 250SMA 8 3GBP254210-��G
37
M3BP 280SMA 8 3GBP284210-��G
45
M3BP 280SMB 8 3GBP284220-��G
55
M3BP 315SMA 8 3GBP314210-��G
75
M3BP 315SMB 8 3GBP314220-��G
90
M3BP 315SMC 8 3GBP314230-��G
110
M3BP 315MLA 8 3GBP314410-��G
132
M3BP 355SMA 8 3GBP354210-��G
160
M3BP 355SMB 8 3GBP354220-��G
200
M3BP 355SMC 8 3GBP354230-��G
250
M3BP 355MLB 8 3GBP354420-��G
315
M3BP 400LA 8 3GBP404510-��G
315
M3BP 400LKA 8 3GBP404810-��G
315 3) M3BP 355LKB 8 3GBP354820-��G
355
M3BP 400LB 8 3GBP404520-��G
355
M3BP 400LKB 8 3GBP404820-��G
400
M3BP 400LC 8 3GBP404530-��G
400
M3BP 400LKC 8 3GBP404830-��G
450
M3BP 450LA 8 3GBP454510-��G
500
M3BP 450LB 8 3GBP454520-��G
560
M3BP 450LC 8 3GBP454530-��G
630 3) M3BP 450LD 8 3GBP454540-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 660 49.4 46.4 39.7 670 51.5 47.6 40.0 700 57.4 53.7 46.1 680 61.5 61.3 53.5 705 66.3 64.0 57.0 655 61.8 65.6 65.2 710 74.0 72.3 67.1 695 76.0 76.4 74.5 690 74.4 75.9 74.1 715 78.3 75.1 75.5 715 79.9 79.7 76.6 728 84.0 85.1 83.6 726 84.6 85.9 84.8 727 86.0 87.3 86.5 731 86.9 87.6 86.7 737 89.5 90.8 90.3 739 90.0 91.1 90.6 738 90.5 91.4 91.0 742 91.2 91.8 91.1 741 91.7 92.0 91.2 741 92.1 92.3 91.7 742 92.4 93.0 92.4 741 93.0 93.2 93.0 741 93.3 93.7 93.3 740 93.6 93.9 94.0 744 93.9 93.8 93.3 744 94.2 94.2 93.7 742 94.5 95.0 94.8 743 94.5 94.7 94.1 744 96.1 96.0 95.6 744 96.1 96.0 95.6 742 95.5 95.7 95.2 743 95.8 96.0 95.8 743 95.8 96.0 95.8 744 96.0 96.3 95.8 744 96.0 96.3 95.8 744 96.2 96.5 96.2 744 96.3 96.4 96.2 744 96.4 96.5 96.1 745 96.6 96.7 96.2
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.60 0.44 2.7 1.3
2.0 2.5 0.00089
0.56 0.6 2.7 1.7
2.0 2.5 0.0011
0.62 0.78 3.2 2.5
2.1 2.8 0.00187
0.65 0.94 3.1 3.5
1.9 2.6 0.00239
0.54 1.43 2.8 5
1.9 2.5 0.00444
0.67 1.92 2.6 8
1.4 1.9 0.00491
0.61 2.48 3.7 10.1 1.8 2.6 0.0072
0.66 3.12 3.6 15.1 1.6 2.3 0.00871
0.74 4.11 3.5 20.9 1.9 2.6 0.0106
0.66 6.51 4.7 29.2 1.6 2.8 0.0334
0.64 8.5 4.7 39.7 1.7 2.8 0.04
0.67 10.2 5.4 52.4 1.5 2.6 0.068
0.67 13.9 5.6 72.3 1.4 2.6 0.085
0.65 19.3 4.7 98.5 1.5 2.8 0.132
0.67 27.3 4.4 143 1.8 2.6 0.214
0.74 32.4 5.3 194 2.0 2.4 0.45
0.73 40.1 5.2 239 2.0 2.3 0.669
0.74 46.8 5.5 284 2.0 2.3 0.722
0.71 66 5.8 386 2.6 2.4 1.4
0.79 72.6 7.3 476 1.7 3.0 1.85
0.78 89.2 7.6 579 1.8 3.1 2.2
0.79 106 7.1 707 1.6 2.7 3.2
0.82 146 7.1 966 1.7 2.7 4.1
0.82 170 7.4 1159 1.8 2.7 4.9
0.83 211 7.3 1419 1.8 2.7 5.8
0.80 256 7.5 1694 1.5 2.6 7.9
0.77 293 7.6 2053 1.6 2.6 9.7
0.79 385 7.4 2576 1.6 2.6 11.3
0.80 472 7.5 3213 1.6 2.7 13.5
0.81 592 7.0 4043 1.2 2.6 17
0.81 592 7.0 4043 1.2 2.6 17
0.80 595 7.9 4053 1.7 2.7 16.5
0.83 641 6.8 4562 1.2 2.5 21
0.83 641 6.8 4562 1.2 2.5 21
0.82 735 6.0 5134 1.3 2.7 24
0.82 735 6.0 5134 1.3 2.7 24
0.83 813 6.0 5775 1.0 2.5 26
0.83 902 6.4 6417 1.0 2.6 29
0.82 1038 7.0 7188 1.2 2.9 35
0.81 1162 7.6 8075 1.3 3.2 41
Weight kg
Sound
pressure
Level LPA dB
11
40
12
43
15
45
17
50
24
50
25
53
30
46
30
53
39
55
70
56
75
58
120 59
134 59
184 59
233 59
290 60
350 63
363 63
440 63
605 65
645 65
830 62
930 62
1000 64
1150 72
1520 69
1680 69
1820 69
2180 72
2900 71
2900 71
2600 75
3200 71
3200 71
3400 71
3400 71
3750 80
4000 80
4350 80
4800 80
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
26
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
750 r/min = 8 poles
18.5
M3BP 200MLB 8 3GBP204420-��G
30
M3BP 225SMC 8 3GBP224230-��G
37
M3BP 250SMB 8 3GBP254220-��G
45
3) M3BP 250SMC 8 3GBP254230-��G
55
M3BP 280SMC 8 3GBP284230-��G
75
M3BP 280MLB 8 3GBP284420-��G
132
M3BP 315LKA 8 3GBP314810-��G
150 3) M3BP 315LKB 8 3GBP314820-��G
160 3) M3BP 315LKC 8 3GBP314830-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 739 90.0 90.8 90.2 737 91.2 92.3 92.1 740 91.7 92.8 92.5 738 92.1 93.3 93.3 741 92.4 92.8 92.7 739 93.7 93.9 93.3 740 94.1 94.4 94.2 741 94.1 94.7 94.6 739 94.2 94.7 94.7
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.74 40 5.4 239 2.1 2.3 0.53
0.73 64.7 5.6 388 2.3 2.4 0.828
0.73 78.9 5.4 477 2.6 2.3 1.51
0.74 95.1 5.6 582 2.3 2.4 1.51
0.80 107 7.9 708 1.9 3.1 2.85
0.80 144 6.7 969 1.7 2.6 4.1
0.83 243 7.3 1703 1.8 2.6 7.3
0.83 278 7.7 1938 1.9 2.7 8.3
0.83 297 7.7 2068 1.9 2.8 9.2
Weight kg
Sound
pressure
Level LPA dB
318 60 393 63 468 63 468 63 725 65 890 72 1410 74 1520 74 1600 74
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
ABB Motors and Generators | 9AKK105944 EN 02-2020
27
Technical data, 400 V 50 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
600 r/min = 10 poles
15
M3BP 200MLB 10 3GBP205420-��G
37
M3BP 280SMB 10 3GBP285220-��G
45
M3BP 280SMC 10 3GBP285230-��G
55
M3BP 315SMB 10 3GBP315220-��G
75
M3BP 315SMC 10 3GBP315230-��G
90
M3BP 315MLA 10 3GBP315410-��G
110
M3BP 355SMA 10 3GBP355210-��G
132
M3BP 355SMB 10 3GBP355220-��G
160
M3BP 355SMC 10 3GBP355230-��G
200
M3BP 355MLB 10 3GBP355420-��G
250 3) M3BP 355LKB 10 3GBP355820-��G
250
M3BP 400LB 10 3GBP405520-��G
315
M3BP 400LC 10 3GBP405530-��G
355
M3BP 450LA 10 3GBP455510-��G
400
M3BP 450LB 10 3GBP455520-��G
450
M3BP 450LC 10 3GBP455530-��G
500 3) M3BP 450LD 10 3GBP455540-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 587 88.2 88.4 86.9 593 92.5 92.3 90.9 592 93.0 92.9 91.7 594 93.8 93.8 92.9 593 93.6 93.7 92.8 593 93.7 93.8 93.0 595 94.5 94.5 93.6 594 94.8 94.9 94.2 594 94.8 94.9 94.2 594 95.0 95.1 94.5 593 95.1 95.3 94.8 595 95.3 95.3 94.5 595 95.4 95.4 94.7 596 95.9 95.9 95.2 596 95.9 95.9 95.1 596 96.1 96.1 95.4 596 96.1 96.1 95.4
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.71 34.5 5.3 244 1.7 2.4 0.54
0.73 79 6.6 595 1.6 3.0 2.2
0.75 93.1 6.7 725 1.6 2.8 2.85
0.78 108 6.7 884 1.6 2.7 4.1
0.78 148 6.6 1207 1.5 2.8 4.9
0.78 177 6.6 1449 1.7 2.7 5.8
0.76 221 6.6 1765 1.3 2.5 7.9
0.79 254 6.6 2122 1.3 2.4 9.7
0.77 316 6.9 2572 1.4 2.5 11.3
0.78 389 6.5 3215 1.4 2.4 13.5
0.78 486 6.3 4025 1.4 2.3 16.5
0.74 511 6.2 4012 1.3 2.3 20
0.74 644 6.2 5055 1.3 2.3 24
0.72 742 5.8 5687 1.1 2.2 31
0.72 836 5.7 6408 1.0 2.1 34
0.73 925 5.8 7210 1.0 2.1 38
0.71 1057 5.9 8011 1.1 2.2 42
Weight kg
Sound
pressure
Level LPA dB
305 61 645 60 725 60 930 70 1000 70 1150 70 1520 73 1680 73 1820 76 2180 77 2600 79 3100 79 3400 79 4050 82 4250 82 4550 82 4800 82
Output kW
Motor type
Product code
500 r/min = 12 poles
30
M3BP 280SMB 12 3GBP286220-��G
37
M3BP 280SMC 12 3GBP286230-��G
45
M3BP 315SMB 12 3GBP316220-��G
55
M3BP 315SMC 12 3GBP316230-��G
75
M3BP 315MLA 12 3GBP316410-��G
90
M3BP 355SMA 12 3GBP356210-��G
110
M3BP 355SMB 12 3GBP356220-��G
132
M3BP 355SMC 12 3GBP356230-��G
160
M3BP 355MLB 12 3GBP356420-��G
200 3) M3BP 355LKB 12 3GBP356820-��G
200
M3BP 400LB 12 3GBP406520-��G
315
M3BP 450LB 12 3GBP456520-��G
400 3) M3BP 450LD 12 3GBP456540-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 493 90.2 89.5 493 90.6 89.8 494 92.8 92.9 493 93.0 93.2 493 93.2 93.4 495 93.5 93.5 495 93.8 93.8 495 93.9 93.9 494 93.8 94.0 494 93.9 94.1 495 95.0 95.0 496 95.6 95.6 495 95.7 95.8
86.9 87.2 92.0 92.4 92.8 92.5 92.7 92.9 93.3 93.4 94.3 94.8 95.2
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.59 81.3 5.8 581 1.9 3.0 2.2
0.58 101 6.3 716 2.0 3.2 2.85
0.76 92 6.5 869 1.6 2.6 4.1
0.77 110 6.5 1065 1.6 2.6 4.9
0.76 152 6.3 1452 1.5 2.5 5.8
0.72 192 5.7 1736 1.3 2.4 7.9
0.71 238 6.0 2122 1.4 2.5 9.7
0.71 285 6.0 2546 1.4 2.5 11.3
0.74 332 5.7 3092 1.3 2.4 13.5
0.73 421 5.8 3866 1.4 2.4 16.5
0.79 384 5.4 3858 1.1 2.2 20
0.76 625 5.5 6064 1.0 2.1 34
0.77 783 5.3 7716 1.0 2.0 42
Weight kg
Sound
pressure
Level LPA dB
645 71 725 71 930 71 1000 71 1150 71 1520 75 1680 75 1820 77 2180 77 2600 79 3100 82 4300 82 4800 82
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
28
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 460 V 60 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3600 r/min = 2 poles
0.37
M3BP 71MA 2 3GBP071321-��B
0.55
M3BP 71MB 2 3GBP071322-��B
0.75
M3BP 80MB 2 3GBP081322-��B
1.1
M3BP 80MC 2 3GBP081323-��B
1.5
M3BP 90SLB 2 3GBP091322-��B
2.2
M3BP 90SLC 2 3GBP091323-��B
3
4) M3BP 100LB 2 3GBP101322-��B
4
4) M3BP 112MB 2 3GBP111322-��B
5.5 4) M3BP 132SMB 2 3GBP131322-��B
7.5
M3BP 132SMC 2 3GBP131324-��B
11
M3BP 160MLA 2 3GBP161410-��G
15
M3BP 160MLB 2 3GBP161420-��G
18.5
M3BP 160MLC 2 3GBP161430-��G
22
M3BP 180MLA 2 3GBP181410-��G
30
M3BP 200MLA 2 3GBP201410-��G
37
M3BP 200MLB 2 3GBP201420-��G
45
M3BP 225SMA 2 3GBP221210-��G
55
M3BP 250SMA 2 3GBP251210-��G
75
M3BP 280SMA 2 3GBP281210-��N
90
M3BP 280SMB 2 3GBP281220-��N
110
M3BP 315SA 2 3GBP311110-��N
132
M3BP 315SMA 2 3GBP311210-��N
160
M3BP 315SMB 2 3GBP311220-��N
200 1)4) M3BP 315MLA 2 3GBP311410-��G
250 1) M3BP 355SMA 2 3GBP351210-��G
315 1) M3BP 355SMB 2 3GBP351220-��G
355 1) M3BP 355SMC 2 3GBP351230-��G
400 1) M3BP 355MLA 2 3GBP351410-��G
450 1)3) M3BP 355MLB 2 3GBP351420-��G
500 1) M3BP 355LKA 2 3GBP351810-��G
560 1) M3BP 400LA 2 3GBP401510-��G
560 1) M3BP 400LKA 2 3GBP401810-��G
630 1) M3BP 400LB 2 3GBP401520-��G
630 1) M3BP 400LKB 2 3GBP401820-��G
710 1) M3BP 400LC 2 3GBP401530-��G
710 1) M3BP 400LKC 2 3GBP401830-��G
800 1)3) M3BP 450LA 2 3GBP451510-��G
900 1)3) M3BP 450LB 2 3GBP451520-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
3389 3439 3510 3490 3505 3500 3530 3510 3485 3505 3547 3545 3543 3559 3562 3564 3566 3571 3575 3574 3581 3579 3579 3582 3585 3582 3586 3582 3585 3584 3588 3588 3588 3588 3588 3588 3591 3591
460 V 60 Hz 76.7 76.4 79.4 81.1 80.3 78.3 82.9 81.8 84.4 84.0 85.5 85.5 87.0 85.7 85.0 84.4 86.0 85.3 89.5 89.1 90.9 91.0 90.9 91.2 91.6 92.1 91.6 91.6 92.3 92.0 92.9 92.7 93.5 93.2 93.5 93.2 93.6 93.2 94.5 94.3 94.5 94.1 95.0 94.6 95.0 94.8 95.1 94.7 95.5 95.0 95.6 95.3 95.7 95.3 96.4 95.9 96.2 95.8 96.2 95.9 96.2 95.8 96.2 95.8 96.2 96.0 96.2 96.0 96.2 96.0 96.2 96.0 96.2 95.9 96.2 95.9
73.2 79.9 73.6 78.4 81.6 83.5 82.4 82.1 82.8 86.8 89.8 90.0 91.3 90.3 90.4 91.0 91.7 91.7 91.5 93.3 92.6 93.3 93.9 93.5 93.6 94.1 94.2 94.7 94.8 95.0 94.5 94.5 95.9 95.9 95.2 95.2 94.7 95.1
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.80 0.78 5.5 1.03 2.6 2.9 0.00039
0.83 1.04 6.0 1.52 3.0 3.5 0.00051
0.72 1.62 9.1 2.04 4.9 5.2 0.001
0.80 2.12 7.5 3.0
4.3 5.5 0.0012
0.87 2.57 7.5 4.07 2.8 3.1 0.00254
0.88 3.58 7.9 5.98 1.7 2.9 0.0028
0.87 5.1 9.1 8.0
3.4 4.2 0.00528
0.89 6.6 9.5 10.84 3.2 3.8 0.00575
0.87 8.6 7.9 15.01 2.6 3.1 0.0128
0.88 12.1 8.3 20.48 2.5 4.4 0.0136
0.90 16.7 8.6 29.6 2.6 3.5 0.044
0.90 22.4 8.7 40.4 2.7 3.8 0.053
0.92 27.2 8.7 49.8 3.1 3.8 0.063
0.87 34.3 8.8 59
3.0 3.8 0.076
0.90 44.9 8.7 80.4 2.8 3.4 0.178
0.89 55.8 9.2 99.1 3.1 3.7 0.196
0.88 68.6 7.7 120 2.6 2.7 0.244
0.88 83.2 7.7 147 2.3 3.0 0.507
0.89 112 8.9 200 2.7 3.2 0.61
0.90 132 8.6 240 3.0 3.5 0.73
0.90 163 8.4 293 2.7 3.4 0.95
0.90 194 8.2 352 2.8 3.3 1.1
0.91 233 8.3 426 2.7 3.4 1.25
0.90 293 8.7 532 2.7 3.3 2.1
0.89 370 8.6 665 1.8 3.7 3
0.89 466 7.8 839 2.2 3.3 3.4
0.88 528 8.1 945 2.2 3.3 3.6
0.88 589 8.3 1066 2.3 3.2 4.1
0.90 650 8.9 1199 2.2 3.2 4.3
0.90 722 9.0 1332.26 2.4 4.3 4.8
0.89 818 9.0 1490 2.3 3.8 7.9
0.89 818 9.0 1490 2.3 3.8 7.9
0.89 916 8.6 1676 3.0 4.5 8.2
0.89 916 8.6 1676 3.0 4.5 8.2
0.90 1026 8.4 1890 2.9 4.0 9.3
0.90 1026 8.4 1890 2.9 4.0 9.3
0.87 1188 8.0 2127 1.3 3.5 12.2
0.85 1366 7.8 2393 1.5 3.4 13.5
Weight kg
Sound
pressure
Level LPA dB
11
61
11
59
16
60
18
63
24
72
25
67
36
71
37
73
68
73
70
73
127
73
141
73
170
73
190 73
283 76
298 76
347 78
405 79
540 81
590 81
770 82
865 82
925 82
1190 83
1600 86
1680 86
1750 88
2000 88
2080 88
2320 88
2950 86
2950 86
3050 86
3050 86
3300 86
3300 86
4000
4200
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
ABB Motors and Generators | 9AKK105944 EN 02-2020
29
Technical data, 460 V 60 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3600 r/min = 2 poles
22
M3BP 160MLD 2 3GBP161440-��G
27
M3BP 160MLE 2 3GBP161450-��G
30
M3BP 180MLB 2 3GBP181420-��G
45
M3BP 200MLC 2 3GBP201430-��G
55
M3BP 200MLD 2 3GBP201440-��G
55
M3BP 225SMB 2 3GBP221220-��G
75
M3BP 225SMC 2 3GBP221230-��G
75
M3BP 250SMB 2 3GBP251220-��G
80
M3BP 225SMD 2 3GBP221240-��G
90
M3BP 250SMC 2 3GBP251230-��G
110 1)3) M3BP 280SMC 2 3GBP281230-��G
132 1)3) M3BP 280MLA 2 3GBP281410-��G
160 1)3) M3BP 280MLB 2 3GBP281420-��G
250 1)3)4) M3BP 315LKA 2 3GBP311810-��G
315 1)3)4) M3BP 315LKC 2 3GBP311830-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
460 V 60 Hz 3546 91.6 92.1 91.2 3546 92.3 92.8 92.1 3558 92.3 92.4 91.7 3563 93.4 93.3 92.2 3560 93.5 93.7 92.6 3567 93.5 93.3 91.8 3573 94.0 93.8 92.7 3575 94.0 93.9 92.8 3570 94.0 93.8 92.7 3575 94.9 94.8 93.6 3580 94.0 93.6 92.3 3579 95.0 94.8 93.7 3578 95.0 94.9 93.9 3582 95.2 94.9 93.8 3583 95.2 95.0 94.1
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
Weight kg
Sound
pressure
Level LPA dB
High-output design
0.91 32.8 9.3 59.2 3.4 4.1 0.063
170
73
0.90 40.4 9.1 72.8 3.3 3.9 0.072
184 73
0.89 45.4 9.2 80.5 3.1 3.8 0.092
208 73
0.88 68.7 9.2 120 3.2 3.7 0.196
298 76
0.89 82.2 9.0 147 3.1 3.7 0.217
314 76
0.89 82.6 7.5 147 2.5 2.8 0.274
369 78
0.86 116 8.7 200 3.3 3.4 0.309
396 78
0.89 111 8.6 200 2.9 3.4 0.583
451 79
0.88 120 8.4 213 3.1 3.2 0.329
410 78
0.89 133 8.6 240 2.7 3.4 0.644
487 79
0.90 163 8.9 292 2.5 3.3 1.15
725 82
0.90 193 8.5 351 2.6 3.3 1.4
840 83
0.91 230 8.6 426 2.9 3.3 1.55
890 83
0.89 371 8.7 666 2.9 3.2 2.65
1440 83
0.89 467 10.1 839 3.4 3.5 3.3
1630 83
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
30
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 460 V 60 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1800 r/min = 4 poles
0.25
M3BP 71MA 4 3GBP072321-��B
0.37
M3BP 71MB 4 3GBP072322-��B
0.55
M3BP 80MA 4 3GBP082321-��B
0.75
M3BP 80MD 4 3GBP082324-��B
1.1
M3BP 90SLB 4 3GBP092322-��B
1.5
M3BP 90SLD 4 3GBP092325-��B
2.2
M3BP 100LC 4 3GBP102323-��B
3
M3BP 100LD 4 3GBP102324-��B
4
M3BP 112MB 4 3GBP112322-��B
5.5
M3BP 132SMB 4 3GBP132322-��B
7.5
M3BP 132SMC 4 3GBP132323-��B
11
M3BP 160MLA 4 3GBP162410-��G
15
M3BP 160MLB 4 3GBP162420-��G
18.5
M3BP 180MLA 4 3GBP182410-��G
22
M3BP 180MLB 4 3GBP182420-��G
30
M3BP 200MLA 4 3GBP202410-��G
37
M3BP 225SMA 4 3GBP222210-��G
45
M3BP 225SMB 4 3GBP222220-��G
55
M3BP 250SMA 4 3GBP252210-��G
75
M3BP 280SMA 4 3GBP282210-��N
90
M3BP 280SMB 4 3GBP282220-��N
110
M3BP 315SA 4 3GBP312110-��N
132
M3BP 315SMA 4 3GBP312210-��N
160
M3BP 315SMB 4 3GBP312220-��N
200
M3BP 315MLA 4 3GBP312410-��G
250
M3BP 355SMA 4 3GBP352210-��G
315
M3BP 355SMB 4 3GBP352220-��G
355
M3BP 355SMC 4 3GBP352230-��G
400
M3BP 355SMC 4 3GBP352230-��G
450
M3BP 355MLA 4 3GBP352410-��G
500
M3BP 355MLB 4 3GBP352420-��G
500
M3BP 355LKA 4 3GBP352810-��G
560 3) M3BP 355LKB 4 3GBP352820-��G
560
M3BP 400LA 4 3GBP402510-��G
560
M3BP 400LKA 4 3GBP402810-��G
630
M3BP 400LB 4 3GBP402520-��G
630
M3BP 400LKB 4 3GBP402820-��G
710 3) M3BP 400LC 4 3GBP402530-��G
710 3) M3BP 400LKC 4 3GBP402830-��G
800
M3BP 450LA 4 3GBP452510-��G
900
M3BP 450LB 4 3GBP452520-��G
1000
M3BP 450LC 4 3GBP452530-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1705 1710 1701 1740 1740 1740 1755 1755 1745 1765 1760 1772 1775 1781 1780 1783 1782 1784 1782 1786 1784 1787 1785 1786 1787 1789 1789 1788 1787 1789 1790 1791 1791 1792 1792 1792 1792 1792 1792 1792 1792 1792
460 V 60 Hz 73.2 73.3 75.1 74.9 75.5 76.0 82.5 81.7 84.0 83.6 86.1 86.0 87.5 86.7 87.6 87.2 87.7 87.6 89.9 89.6 90.5 90.4 91.3 91.6 92.2 92.3 92.5 92.8 93.1 93.4 93.8 94.0 93.6 93.5 94.2 94.1 95.0 95.2 94.5 94.4 94.5 94.5 95.0 95.0 95.0 95.1 95.0 95.0 95.2 95.1 95.4 95.3 95.8 95.7 95.8 95.7 95.9 96.0 95.8 95.8 96.2 96.0 96.8 96.3 96.4 96.2 96.2 96.0 96.2 96.0 96.2 96.0 96.2 96.0 96.8 96.6 96.8 96.6 96.2 95.9 96.8 96.3 96.8 96.6
70.5 71.9 72.3 78.5 81.0 84.0 84.3 85.0 86.0 87.5 88.8 90.5 91.5 92.0 92.5 93.1 92.4 93.0 94.7 93.4 93.8 94.4 94.5 94.3 94.3 94.4 94.8 94.9 95.6 95.0 95.3 95.2 95.6 95.3 95.3 95.4 95.4 96.0 96.0 95.3 96.0 95.8
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.76 0.56 4.3 1.42 2.3 2.6 0.00074
0.78 0.77 5.5 2.05 1.9 2.7 0.00088
0.70 1.39 6.1 3.01 2.4 3.6 0.00144
0.69 1.64 7.4 4.12 3.6 3.9 0.002
0.77 2.11 7.5 6.0
2.7 4.0 0.0044
0.81 2.74 7.8 8.2
3.0 4.1 0.0053
0.78 4.08 9.0 12
3.0 4.8 0.00948
0.78 5.42 9.1 16.35 3.2 4.1 0.011
0.82 6.94 8.2 21.96 2.8 3.4 0.0125
0.79 9.64 7.6 29.8 2.4 3.6 0.0328
0.82 12.7 8.2 40.88 2.7 4.1 0.0366
0.83 18.2 7.7 59.2 2.4 3.2 0.081
0.83 24.6 8.0 80.6 2.7 3.3 0.099
0.83 30.2 8.2 99.1 2.8 3.2 0.166
0.83 35.7 8.3 118 2.8 3.3 0.195
0.83 48.3 8.4 160 3.0 3.3 0.309
0.84 59 8.1 198 2.8 3.2 0.356
0.85 70.5 8.6 240 2.7 3.3 0.44
0.84 86.3 8.0 294 2.8 3.3 0.765
0.83 119 8.9 401 3.8 3.7 0.91
0.84 141 8.7 482 3.3 3.8 1.13
0.85 170 7.6 588 2.9 3.1 1.5
0.87 199 7.4 706 2.7 3.0 2
0.85 246 7.8 856 2.9 3.2 2.2
0.86 307 8.2 1068 2.7 3.2 3.5
0.85 388 8.0 1334 2.4 3.0 5.9
0.86 481 8.3 1680 2.4 3.1 6.9
0.87 536 7.8 1894 2.5 3.0 7.2
0.87 601 6.9 2137 2.2 2.7 7.2
0.86 683 7.0 2402 2.2 2.6 8.4
0.86 755 7.3 2667 2.3 3.0 8.4
0.85 763 8.0 2666 2.4 3.4 10
0.85 858 8.5 2988 2.8 2.9 10.6
0.84 863 7.8 2985 2.7 3.1 15
0.84 863 7.8 2985 2.7 3.1 15
0.85 959 8.9 3358 2.2 3.3 16
0.85 959 8.9 3358 2.2 3.3 16
0.84 1091 7.9 3784 2.5 3.3 17
0.84 1091 7.9 3784 2.5 3.3 17
0.86 1256 6.5 4263 1.3 3.1 23
0.85 1373 7.9 4794 1.3 3.1 25
0.86 1505 7.2 5329 1.4 2.8 30
Weight kg
Sound
pressure
Level LPA dB
10
48
11
48
15
48
17
53
25
53
27
59
36
59
38
61
44
62
70
70
73
67
135 66
165 66
205 66
222 66
291 67
324 70
356 70
414 71
540 74
610 74
740 73
900 73
940 73
1160 74
1610 79
1780 74
1820 78
1820 83
2140 83
2140 83
2500 83
2600 83
3200 83
3200 83
3300 83
3300 83
3400 83
3400 83
4050 89
4350 89
4700 89
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
ABB Motors and Generators | 9AKK105944 EN 02-2020
31
Technical data, 460 V 60 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1800 r/min = 4 poles
18.5
M3BP 160MLC 4 3GBP162430-��G
22
M3BP 160MLD 4 3GBP162440-��G
30
M3BP 180MLC 4 3GBP182430-��G
37
M3BP 200MLB 4 3GBP202420-��G
45
M3BP 200MLC 4 3GBP202430-��G
55
M3BP 225SMC 4 3GBP222230-��G
64
M3BP 225SMD 4 3GBP222240-��G
75
M3BP 250SMB 4 3GBP252220-��G
90
M3BP 250SMC 4 3GBP252230-��G
110
M3BP 280SMC 4 3GBP282230-��G
132
M3BP 280MLA 4 3GBP282410-��G
160
M3BP 280MLB 4 3GBP282420-��G
250 4) M3BP 315LKA 4 3GBP312810-��G
315 4) M3BP 315LKC 4 3GBP312830-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1774 1770 1777 1783 1783 1782 1783 1782 1776 1786 1785 1785 1788 1789
460 V 60 Hz 92.4 92.7 92.5 93.2 93.2 93.6 94.2 94.5 94.4 94.5 94.4 94.5 94.4 94.4 94.8 95.0 95.2 95.3 95.2 95.2 95.3 95.3 95.6 95.6 95.3 95.1 95.3 95.1
92.1 92.6 93.0 94.1 93.9 93.8 93.4 94.4 94.6 94.3 94.4 95.0 94.1 94.1
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.83 30.2 8.7 99.5 3.3 3.6 0.11
0.84 35.4 7.8 118 2.7 3.3 0.125
0.83 48.6 8.3 161 2.9 3.3 0.217
0.84 58.6 8.5 198 2.8 3.3 0.343
0.83 72 8.6 241 3.2 3.6 0.366
0.85 86 8.5 294 3.1 3.4 0.474
0.85 100 9.4 342 3.5 3.7 0.542
0.85 116 8.4 401 3.1 3.5 0.866
0.84 141 8.6 483 3.5 3.7 0.941
0.86 169 8.7 587 3.2 3.3 1.85
0.86 202 8.1 705 2.9 3.1 2.3
0.85 247 7.3 855 3.1 3.2 2.5
0.85 389 8.4 1334 2.7 3.2 4.4
0.85 490 9.0 1680 2.9 3.6 5.5
Weight kg
Sound
pressure
Level LPA dB
173
66
187
66
235 66
307 67
319
67
370 70
399 70
450 71
478 71
725 72
840 77
890 77
1410 82
1600 82
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
32
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 460 V 60 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1200 r/min = 6 poles
0.18
M3BP 71MA 6 3GBP073321-��B
0.25
M3BP 71MB 6 3GBP073322-��B
0.37
M3BP 80MA 6 3GBP083321-��B
0.55
M3BP 80MB 6 3GBP083322-��B
0.75
M3BP 90SLC 6 3GBP093323-��B
1.1
4) M3BP 90SLE 6 3GBP093324-��B
1.5
4) M3BP 100L 6
3GBP103322-��B
2.2 4) M3BP 112MB 6 3GBP113322-��B
3
4) M3BP 132SMB 6 3GBP133321-��B
4
4) M3BP 132SMC 6 3GBP133322-��B
5.5 4) M3BP 132SMF 6 3GBP133324-��B
7.5
M3BP 160MLA 6 3GBP163410-��G
11
M3BP 160MLB 6 3GBP163420-��G
15
M3BP 180MLA 6 3GBP183410-��G
18.5
M3BP 200MLA 6 3GBP203410-��G
22
M3BP 200MLB 6 3GBP203420-��G
30
M3BP 225SMA 6 3GBP223210-��G
37
M3BP 250SMA 6 3GBP253210-��G
45
M3BP 280SMA 6 3GBP283210-��N
55
M3BP 280SMB 6 3GBP283220-��N
75
M3BP 315SA 6 3GBP313110-��N
90
M3BP 315SMA 6 3GBP313210-��N
110
M3BP 315SMB 6 3GBP313220-��N
132
M3BP 315MLA 6 3GBP313410-��G
160
M3BP 355SMA 6 3GBP353210-��G
200
M3BP 355SMB 6 3GBP353220-��G
250
M3BP 355SMC 6 3GBP353230-��G
315
M3BP 355MLB 6 3GBP353420-��G
355
M3BP 355LKA 6 3GBP353810-��G
400
M3BP 400LA 6 3GBP403510-��G
400
M3BP 400LKA 6 3GBP403810-��G
400
M3BP 355LKB 6 3GBP353820-��G
450
M3BP 400LB 6 3GBP403520-��G
450
M3BP 400LKB 6 3GBP403820-��G
500
M3BP 400LC 6 3GBP403530-��G
500
M3BP 400LKC 6 3GBP403830-��G
560
M3BP 400LD 6 3GBP403540-��G
560
M3BP 400LKD 6 3GBP403840-��G
630
M3BP 450LA 6 3GBP453510-��G
710
M3BP 450LA 6 3GBP453510-��G
710
M3BP 450LB 6 3GBP453520-��G
800
M3BP 450LB 6 3GBP453520-��G
800 3) M3BP 450LC 6 3GBP453530-��G
900 3) M3BP 450LC 6 3GBP453530-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1120 1125 1135 1135 1160 1140 1160 1160 1180 1165 1165 1179 1177 1181 1190 1189 1189 1191 1191 1192 1191 1191 1191 1192 1194 1194 1194 1193 1193 1194 1194 1193 1194 1194 1194 1194 1194 1194 1195 1194 1196 1194 1195 1195
460 V 60 Hz 69.0 68.2 72.6 71.3 74.5 73.7 71.2 70.8 80.4 78.2 81.2 81.0 82.4 82.0 84.8 84.4 86.3 84.8 86.8 86.3 87.4 86.8 89.6 90.0 90.4 91.0 91.3 91.7 92.2 92.2 92.7 93.1 93.2 93.4 93.6 93.8 93.6 93.5 93.6 93.5 94.1 94.2 94.1 94.1 95.0 94.9 95.1 95.1 95.0 94.9 95.0 94.9 95.3 95.2 95.9 95.7 95.8 95.5 95.8 95.6 95.8 95.6 95.7 95.5 95.8 95.5 95.8 95.5 95.8 95.6 95.8 95.6 95.8 95.6 95.8 95.6 96.5 96.3 96.5 96.5 96.5 96.3 96.5 96.5 96.5 98.6 96.5 96.5
63.6 66.0 69.3 65.5 73.0 78.0 79.4 81.9 81.0 84.0 84.5 88.9 90.0 90.8 91.2 92.2 92.4 93.1 92.5 93.1 93.5 93.0 94.1 94.3 93.9 94.0 94.3 94.8 94.6 94.8 94.8 94.6 94.7 94.7 94.9 94.9 94.9 94.9 95.6 95.9 95.7 95.8 95.5 95.9
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.62 0.52 3.8 1.53 2.5 2.7 0.0009
0.62 0.68 4.4 2.1
3.1 3.4 0.0011
0.64 0.97 4.9 3.1
2.8 3.1 0.0019
0.66 1.34 4.5 4.6
2.1 2.8 0.00239
0.54 2.1 5.1 6.1
2.7 3.7 0.0049
0.65 2.6 4.6 9.2
2.3 2.9 0.0054
0.68 3.31 4.9 12.4 1.6 3.2 0.00873
0.68 4.89 5.0 18.19 1.8 2.7 0.0125
0.62 7.2 6.2 24.36 1.9 3.4 0.0334
0.70 8.58 5.6 32.81 2.3 3.0 0.0334
0.70 11.2 5.7 44.97 2.1 2.7 0.0487
0.77 13.6 7.4 60.7 1.7 3.2 0.087
0.77 19.8 8.4 89.2 2.0 3.4 0.114
0.74 27.8 6.5 121 1.9 3.1 0.168
0.79 31.8 7.5 148 2.5 3.2 0.382
0.81 36.7 7.5 176 2.5 3.2 0.448
0.82 49.2 8.0 240 2.8 3.2 0.663
0.81 61.2 7.6 296 2.6 3.0 1.13
0.81 74.5 7.8 361 2.9 3.0 1.36
0.81 89.9 8.5 440 3.5 3.8 1.8
0.83 121 7.8 601 2.9 2.9 2.6
0.82 146 7.7 721 3.0 3.3 2.8
0.82 178 8.3 882 3.0 3.2 3.5
0.82 211 8.6 1057 3.0 3.3 5.8
0.83 255 7.9 1279 2.2 2.9 7.9
0.83 319 8.2 1599 3.1 3.3 9.7
0.82 403 8.5 1999 2.9 3.2 11.3
0.82 499 8.0 2521 2.8 3.0 13.5
0.80 579 8.7 2842 3.0 3.2 15.5
0.82 637 8.2 3200 2.4 3.0 17
0.82 637 8.2 3200 2.4 3.0 17
0.82 639 7.5 3204 2.7 2.7 16.5
0.82 713 7.9 3598 2.5 3.1 20.5
0.82 713 7.9 3598 2.5 3.1 20.5
0.84 777 8.1 4000 2.6 3.0 22
0.84 777 8.1 4000 2.6 3.0 22
0.85 856 7.8 4481 2.4 3.2 24
0.85 856 7.8 4481 2.4 3.2 24
0.84 978 6.8 5036 1.1 2.9 31
0.84 1099 6.5 5678 1.0 2.4 31
0.85 1085 8.2 5671 1.4 2.9 37
0.85 1221 7.0 6398 1.2 2.5 37
0.84 1235 8.4 6389 1.3 3.1 41
0.84 1392 7.2 7191 1.2 2.7 41
Weight kg
Sound
pressure
Level LPA dB
10
45
12
45
15
49
17
49
25
46
28
47
37
52
44
69
69
60
69
60
86
60
134 63
172
63
207 63
269 67
291 67
349 67
395 67
525 68
600 68
775 70
855 76
960 76
1150 72
1520 80
1680 80
1820 80
2180 80
2500 80
2900 79
2900 79
2600 80
3150 79
3150 79
3300 79
3300 79
3400 79
3400 79
4150 85
4150 85
4500 85
4500 85
4800 85
4800 85
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
ABB Motors and Generators | 9AKK105944 EN 02-2020
33
Technical data, 460 V 60 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1200 r/min = 6 poles
15
M3BP 160MLC 6 3GBP163430-��G
18.5
M3BP 180MLB 6 3GBP183420-��G
30
M3BP 200MLC 6 3GBP203430-��G
37
M3BP 225SMB 6 3GBP223220-��G
45
M3BP 225SMC 6 3GBP223230-��G
45
M3BP 250SMB 6 3GBP253220-��G
55
M3BP 250SMC 6 3GBP253230-��G
75
4) M3BP 280SMC 6 3GBP283230-��G
90
4) M3BP 280MLA 6 3GBP283410-��G
110 4) M3BP 280MLB 6 3GBP283420-��G
160
M3BP 315LKA 6 3GBP313810-��G
180
M3BP 315LKC 6 3GBP313820-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1176 1180 1188 1188 1187 1191 1189 1191 1191 1191 1193 1189
460 V 60 Hz 90.7 91.3 92.0 92.5 93.0 93.3 93.8 94.1 93.6 94.1 93.9 94.2 94.0 94.3 93.2 93.3 93.6 93.5 94.1 94.0 95.0 94.9 95.2 95.3
90.5 91.8 92.5 93.5 93.6 93.5 93.7 92.4 92.4 92.9 93.9 94.6
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.75 27.6 8.1 121 1.9 4.1 0.131
0.78 32.3 6.6 149 1.9 3.0 0.198
0.83 48.7 8.0 241 2.6 3.2 0.531
0.83 59.6 7.5 297 2.5 3.0 0.821
0.82 73.5 7.3 362 2.5 2.9 0.821
0.82 73.3 7.9 360 2.7 3.1 1.37
0.83 88.4 8.1 441 2.9 3.1 1.5
0.84 120 8.4 600 3.1 3.0 2.85
0.81 148 8.2 721 2.6 2.8 3.1
0.82 179 8.7 881 3.0 2.9 4.1
0.82 257 8.6 1280 2.9 3.1 7.3
0.83 316 7.8 1604 2.8 2.9 9.2
Weight kg
Sound
pressure
Level LPA dB
185 63
221
63
318 67
393 67
393 67
441 67
468 67
725 70
840 76
890 76
1410 78
1600 78
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
34
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 460 V 60 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
900 r/min = 8 poles
0.09
M3BP 71MA 8 3GBP074101-��B
0.12
M3BP 71MB 8 3GBP074102-��B
0.18
M3BP 80MA 8 3GBP084101-��B
0.25
M3BP 80MB 8 3GBP084102-��B
0.37
M3BP 90SLB 8 3GBP094102-��B
0.55
M3BP 90SLC 8 3GBP094103-��B
0.75
M3BP 100LA 8 3GBP104101-��B
1.1
M3BP 100LB 8 3GBP104102-��B
1.5
4) M3BP 112M 8
3GBP114101-��B
2.2 4) M3BP 132SMA 8 3GBP134101-��B
3
4) M3BP 132SMB 8 3GBP134102-��B
4
M3BP 160MLA 8 3GBP164410-��G
5.5
M3BP 160MLB 8 3GBP164420-��G
7.5
4) M3BP 160MLC 8 3GBP164430-��G
11
M3BP 180MLA 8 3GBP184410-��G
15
M3BP 200MLA 8 3GBP204410-��G
18.5
M3BP 225SMA 8 3GBP224210-��G
22
M3BP 225SMB 8 3GBP224220-��G
30
M3BP 250SMA 8 3GBP254210-��G
37
M3BP 280SMA 8 3GBP284210-��G
45
M3BP 280SMB 8 3GBP284220-��G
55
M3BP 315SMA 8 3GBP314210-��G
75
M3BP 315SMB 8 3GBP314220-��G
90
M3BP 315SMC 8 3GBP314230-��G
110
M3BP 315MLA 8 3GBP314410-��G
132
M3BP 355SMA 8 3GBP354210-��G
160
M3BP 355SMB 8 3GBP354220-��G
200
M3BP 355SMC 8 3GBP354230-��G
250
M3BP 355MLB 8 3GBP354420-��G
315
M3BP 400LA 8 3GBP404510-��G
315
M3BP 400LKA 8 3GBP404810-��G
315 3) M3BP 355LKB 8 3GBP354820-��G
355
M3BP 400LB 8 3GBP404520-��G
355
M3BP 400LKB 8 3GBP404820-��G
400
M3BP 400LC 8 3GBP404530-��G
400
M3BP 400LKC 8 3GBP404830-��G
450 3) M3BP 400LC 8 3GBP404530-��G
450 3) M3BP 400LKC 8 3GBP404830-��G
560
M3BP 450LC 8 3GBP454530-��G
630 3) M3BP 450LD 8 3GBP454540-��G
710 3) M3BP 450LD 8 3GBP454540-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
460 V 60 Hz 835 53.0 49.4 42.1 840 54.9 49.9 41.5 860 58.9 55.9 49.2 845 64.2 61.8 55.7 860 69.1 66.0 58.1 825 68.1 67.6 62.8 865 77.1 75.5 70.8 855 79.7 79.0 75.5 850 79.2 79.1 76.3 870 80.8 79.6 76.1 870 83.2 82.0 78.4 882 85.8 85.7 83.4 881 86.4 86.6 84.6 882 87.7 87.8 86.2 885 88.6 89.2 87.8 890 90.1 90.5 89.4 890 90.1 90.4 89.0 890 91.6 91.9 90.8 893 91.6 91.6 90.3 893 92.3 92.1 90.6 892 92.3 92.1 90.6 893 93.0 92.8 91.6 892 93.4 93.4 92.4 892 93.9 93.9 93.0 891 93.6 93.7 93.0 895 94.4 94.2 92.9 895 94.4 94.2 92.9 893 94.9 94.8 93.9 893 94.9 94.8 94.0 894 95.5 95.5 94.9 894 95.5 95.5 94.9 893 95.5 95.5 94.7 894 96.3 96.4 95.9 894 96.3 96.4 95.9 895 95.9 96.0 95.3 895 95.9 96.0 95.3 894 96.2 96.2 95.7 894 96.2 96.2 95.7 894 96.1 96.1 95.5 896 96.9 96.8 96.1 895 96.5 96.5 95.9
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.59 0.36 2.4 1.02 2.6 2.8 0.00089
0.49 0.57 3.1 1.35 2.5 3.2 0.0011
0.55 0.74 3.5 2.0
2.4 3.5 0.00187
0.58 0.88 3.5 2.85 2.2 3.2 0.00239
0.51 1.38 3.3 4.1
2.0 2.9 0.00444
0.62 1.7 3.0 6.45 1.6 2.3 0.00491
0.56 2.3 4.1 8.25 2.0 3.2 0.0072
0.61 2.84 4.0 12.2 1.8 2.8 0.00871
0.67 3.64 4.1 16.9 2.1 2.7 0.0106
0.63 5.93 5.2 24.1 1.7 3.2 0.0334
0.63 7.7 5.2 32.75 1.8 3.3 0.04
0.64 9.1 5.9 43.3 1.6 3.0 0.068
0.65 12.2 6.2 59.6 1.5 3.0 0.085
0.63 17 5.1 81.2 1.5 3.2 0.132
0.66 23.5 5.1 118 2.0 2.9 0.214
0.71 28.5 5.9 160 2.3 2.7 0.45
0.72 35 5.9 198 2.2 2.5 0.669
0.73 40.8 6.3 236 2.2 2.6 0.722
0.70 57.8 6.6 320 2.8 2.7 1.4
0.78 64 8.1 395 1.8 3.4 1.85
0.77 79 8.4 481 1.9 3.5 2.2
0.79 93.9 7.8 587 1.7 3.0 3.2
0.78 128 7.9 802 1.8 3.0 4.1
0.80 149 8.2 962 1.9 3.0 4.9
0.79 186 8.1 1178 1.9 3.0 5.8
0.76 230 8.3 1409 1.5 2.9 7.9
0.77 274 8.4 1703 1.6 2.8 9.7
0.79 335 8.2 2143 1.6 2.9 11.3
0.79 417 8.3 2672 1.6 2.9 13.5
0.80 520 7.0 3362 1.2 2.9 17
0.80 520 7.0 3362 1.2 2.9 17
0.79 524 8.8 3369 1.8 2.9 16.5
0.82 564 8.4 3793 1.2 2.8 21
0.82 564 8.4 3793 1.2 2.8 21
0.81 647 6.4 4273 1.3 3.0 24
0.81 647 6.4 4273 1.3 3.0 24
0.82 715 7.3 4806 1.2 2.5 24
0.82 715 7.3 4806 1.2 2.5 24
0.81 907 6.5 5979 1.4 3.1 35
0.81 1013 8.6 6717 1.5 3.4 41
0.82 1126 7.7 7575 1.2 3.2 41
Weight kg
Sound
pressure
Level LPA dB
11
43
12
46
15
48
17
53
24
53
25
56
30
49
30
56
39
58
70
59
75
61
120 63
134 63
184 63
233 63
290 64
350 67
363 67
440 67
605 68
645 69
830 62
930 62
1000 64
1150 76
1520 72
1680 72
1820 72
2180 75
2900 73
2900 73
2600 78
3200 73
3200 73
3400 73
3400 73
3400 73
3400 73
4350 80
4800 80
4800 80
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
ABB Motors and Generators | 9AKK105944 EN 02-2020
35
Technical data, 460 V 60 Hz
IE2 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
900 r/min = 8 poles
18.5
M3BP 200MLB 8 3GBP204420-��G
30
M3BP 225SMC 8 3GBP224230-��G
37
M3BP 250SMB 8 3GBP254220-��G
45
M3BP 250SMC 8 3GBP254230-��G
55
M3BP 280SMC 8 3GBP284230-��G
75
M3BP 280MLB 8 3GBP284420-��G
132
M3BP 315LKA 8 3GBP314810-��G
150 3) M3BP 315LKB 8 3GBP314820-��G
160
M3BP 315LKC 8 3GBP314830-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
460 V 60 Hz 891 90.1 90.4 889 91.6 91.9 891 92.3 92.7 891 92.3 92.9 892 93.2 93.1 890 93.4 93.4 891 94.1 94.2 892 94.1 94.1 890 93.9 94.0
89.0 91.1 92.0 92.3 92.0 92.4 93.6 93.6 93.3
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.72 35.3 6.1 198 2.3 2.6 0.53
0.72 56.3 6.4 322 2.6 2.7 0.828
0.72 68.9 6.1 396 2.8 2.6 1.51
0.74 81.7 6.4 482 2.5 2.7 1.51
0.78 95.2 8.8 588 2.0 3.5 2.85
0.79 126 7.4 804 1.8 2.9 4.1
0.82 214 8.1 1414 1.9 2.9 7.3
0.82 244 8.6 1609 2.0 3.0 8.3
0.82 261 8.5 1717 2.0 3.1 9.2
Weight kg
Sound
pressure
Level LPA dB
318 64 393 67 468 67 468 67 725 69 890 75 1410 78 1520 78 1600 78
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
36
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3000 r/min = 2 poles
0.75
M3BP 80MD 2 3GBP081340-��K
1.1
M3BP 80MG 2 3GBP081370-��K
1.5
M3BP 90LB 2 3GBP091520-��K
2.2
M3BP 90LC 2 3GBP091530-��K
3
M3BP 100LKA 2 3GBP101810-��K
4
M3BP 112MG 2 3GBP111370-��K
5.5
M3BP 132SMF 2 3GBP131260-��K
7.5
M3BP 132SMG 2 3GBP131270-��K
11
M3BP 160MLA 2 3GBP161410-��K
18.5
M3BP 160MLC 2 3GBP161430-��K
22
M3BP 180MLA 2 3GBP181410-��K
30
M3BP 200MLA 2 3GBP201410-��K
37
M3BP 200MLB 2 3GBP201420-��K
45
M3BP 225SMA 2 3GBP221210-��K
55
M3BP 250SMA 2 3GBP251210-��K
75
M3BP 280SMB 2 3GBP281220-��K
90
M3BP 280SMC 2 3GBP281230-��K
110
M3BP 315SMB 2 3GBP311220-��K
132
M3BP 315SMC 2 3GBP311230-��K
160
M3BP 315MLA 2 3GBP311410-��K
200 1) M3BP 355SMA 2 3GBP351210-��K
250 1) M3BP 355SMB 2 3GBP351220-��K
315 1) M3BP 355SMC 2 3GBP351230-��K
355 1) M3BP 355MLA 2 3GBP351410-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
2894 2883 2906 2900 2896 2888 2901 2909 2943 2949 2956 2956 2959 2968 2968 2978 2981 2982 2986 2983 2985 2984 2980 2984
400 V 50 Hz 80.7 80.4 82.7 82.4 84.2 84.7 85.9 87.5 87.1 88.2 88.1 89.4 89.2 89.9 90.1 91.2 91.2 92.0 92.4 93.0 92.7 93.1 93.3 93.7 93.7 93.9 94.0 94.0 94.3 93.7 94.7 94.4 95.7 95.6 95.9 95.9 96.1 96.2 95.6 95.6 96.4 96.1 95.8 95.5 95.8 95.7 95.8 95.8
77.2 80.6 84.6 87.6 88.0 89.6 90.1 91.4 91.6 92.6 92.7 93.0 93.2 93.0 93.6 93.5 95.0 95.2 95.9 94.9 95.3 94.5 95.0 94.9
Current
Power
factor IN Cosj A
IS/IN
B design
0.74 1.7 7.9
0.81 2.3 7.9
0.89 2.8 7.9
0.89 4.0 8.3
0.90 5.4 8.4
0.91 7.1 8.4
0.91 9.7 7.9
0.90 13.1 8.3
0.91 19.1 7.2
0.90 32 9.0
0.90 37.7 7.8
0.90 51.6 7.7
0.90 63.5 8.2
0.87 79.6 7.3
0.89 94.8 6.8
0.88 130 7.0
0.88 153 8.0
0.88 189 6.7
0.88 226 7.9
0.87 275 7.4
0.89 336 7.6
0.89 423 7.7
0.89 531 7.0
0.88 603 7.2
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
2.4
3.7 4.2 0.0008
3.6
3.7 4.2 0.001
4.9
2.3 3.3 0.0027
7.2
2.9 3.5 0.0032
9.8
3.2 3.9 0.0057
13.2 3.2 4.0 0.0104
18.1 2.3 3.4 0.0154
24.6 3.0 3.9 0.0173
35.57 2.6 3.6 0.057
59.81 3.3 3.9 0.076
70.98 3.0 3.8 0.11
96.9 2.7 3.1 0.178
119 3.0 3.3 0.196
145 3.2 3.1 0.296
177
2.4 3.0 0.426
240 2.3 3.0 0.9
288 3.0 3.1 1.15
352 1.9 2.6 1.4
422 2.4 3.0 1.7
512 2.2 2.8 1.7
640 2.0 3.1 3
800 2.1 3.3 3
1009 2.1 3.0 3.4
1136 2.2 3.0 3.6
Weight kg
Sound
pressure
Level LPA dB
18
57
19
56
31
60
35
60
50
62
56
68
77
68
77
70
141
69
183 73
234 73
289 72
314 72
409 76
452 76
665 74
725 77
940 77
1025 77
1190 78
1600 83
1680 83
1750 83
2000 83
Output kW
Motor type
Product code
3000 r/min = 2 poles
200
M3BP 315MLB 2
250
M3BP 315LKB 2
3GBP311420-��K 3GBP311820-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 2983 95.8 95.8 95.3 2982 96.4 96.7 96.7
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.88 342 7.7 640 2.5 3.1 2.1
0.91 413 7.9 800 2.5 2.7 2.9
Weight kg
Sound
pressure
Level LPA dB
1220 81 1540 77
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045.
ABB Motors and Generators | 9AKK105944 EN 02-2020
37
Technical data, 400 V 50 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1500 r/min = 4 poles
0.75
M3BP 90L 4
3GBP092500-��K
0.75
M3BP 80MLG 4 3GBP082470-��K
0.75
M3BP 80MLG 4 3GBP082470-��K
1.1
M3BP 90LC 4 3GBP092530-��K
1.5
M3BP 90LD 4 3GBP092540-��K
2.2
M3BP 100LKA 4 3GBP102810-��K
3
M3BP 100LKB 4 3GBP102820-��K
4
M3BP 112MG 4 3GBP112370-��K
5.5
M3BP 132SMF 4 3GBP132260-��K
7.5
M3BP 132SMG 4 3GBP132270-��K
11
M3BP 160MLA 4 3GBP162410-��K
15
M3BP 160MLB 4 3GBP162420-��K
18.5
M3BP 180MLA 4 3GBP182410-��K
22
M3BP 180MLB 4 3GBP182420-��K
30
M3BP 200MLA 4 3GBP202410-��K
37
M3BP 225SMA 4 3GBP222210-��K
45
M3BP 225SMB 4 3GBP222220-��K
55
M3BP 250SMA 4 3GBP252210-��K
75
M3BP 280SMB 4 3GBP282220-��K
90
M3BP 280SMC 4 3GBP282230-��K
110
M3BP 315SMC 4 3GBP312230-��K
132
M3BP 315SMD 4 3GBP312240-��K
160
M3BP 315MLB 4 3GBP312420-��K
200
M3BP 355SMA 4 3GBP352210-��K
250
M3BP 355SMB 4 3GBP352220-��K
315
M3BP 355SMC 4 3GBP352230-��K
355
M3BP 355MLA 4 3GBP352410-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1448 1440 1449 1442 1439 1454 1452 1454 1463 1464 1477 1477 1481 1480 1483 1482 1482 1485 1485 1485 1491 1490 1490 1491 1491 1491 1490
400 V 50 Hz 85.3 85.7 82.5 82.4 84.1 85.0 84.1 83.5 85.3 84.7 86.7 87.2 87.7 88.1 88.6 89.1 89.6 89.8 90.4 90.8 91.4 91.8 92.1 92.4 92.6 93.2 93.3 94.1 93.6 93.9 93.9 94.1 94.2 94.4 95.4 95.9 95.0 95.2 95.2 95.5 96.2 96.5 96.3 96.6 96.5 96.7 96.6 96.7 96.0 96.0 96.0 96.1 96.0 96.2
84.4 80.2 83.8 81.7 82.8 86.1 87.1 88.6 88.7 90.7 91.1 91.6 92.9 94.1 93.4 93.8 94.0 95.7 94.8 95.2 96.1 96.2 96.4 96.4 95.6 95.7 95.8
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.78 1.62 8.0 4.97 3.9 4.4 0.0056
0.76 1.68 7.9 4.9
3.3 3.7 0.0027
0.79 1.62 7.0 4.94 2.9 3.7 0.0033
0.80 2.3 7.9 7.2
3.3 3.9 0.0055
0.78 3.2 8.2 9.9
3.5 4.0 0.0055
0.83 4.3 8.9 14.5 3.1 4.1 0.0144
0.83 5.9 9.0 19.7 3.5 4.2 0.0144
0.75 8.7 6.9 26.3 3.1 3.3 0.0176
0.74 11.9 7.6 36
2.8 3.9 0.0295
0.81 14.7 7.7 48.9 2.5 3.6 0.0414
0.82 21.1 7.6 71.27 2.6 3.3 0.11
0.82 28.5 8.2 96.99 3.0 3.7 0.135
0.83 34.9 7.2 119 2.8 3.0 0.219
0.82 41.5 8.2 141 2.8 3.1 0.217
0.84 54.8 7.5 193 2.7 3.2 0.385
0.83 68.9 7.2 239 3.1 3.1 0.427
0.84 82.3 8.0 290 3.2 3.5 0.525
0.85 97.8 7.9 353 3.0 3.3 0.933
0.86 133 6.4 483 2.3 2.8 1.38
0.86 158 7.1 578 2.5 2.9 1.73
0.85 194 7.8 704 2.4 3.1 2.9
0.85 234 7.9 846 2.6 3.2 3.2
0.87 278 7.9 1026 2.7 3.0 3.9
0.87 345 7.3 1282 2.1 2.7 5.9
0.86 435 6.4 1601 2.1 2.9 5.9
0.85 550 7.3 2018 2.4 3.3 6.9
0.86 616 6.3 2273 2.3 2.8 7.2
Weight kg
Sound
pressure
Level LPA dB
30
53
22
54
22
57
33
56
34
55
49
54
49
54
52
59
81
70
81
64
188 61
187
61
235 60
235 62
319
63
398 67
398 66
476 67
665 72
725 72
1000 68
1065 68
1220 68
1610 74
1780 78
1820 78
2140 78
Output kW
Motor type
Product code
1500 r/min = 4 poles
200
M3BP 315LKB 4
250
M3BP 315LKC 4
3GBP312820-��K 3GBP312830-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1487 1490
400 V 50 Hz 96.0 96.4 96.6 96.9
96.4 96.8
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.86 351 6.8 1284 2.4 3.0 3.9
0.87 432 7.8 1601 2.3 3.0 5.5
Weight kg
Sound
pressure
Level LPA dB
1520 74 1600 74
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045.
38
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1000 r/min = 6 poles
0.75
M3BP 90LG 6 3GBP093570-��K
1.1
M3BP 100LKG 6 3GBP103870-��K
1.5
M3BP 112MH 6 3GBP113380-��K
2.2
M3BP 132SMC 6 3GBP133230-��K
3
M3BP 132SMD 6 3GBP133240-��K
4
M3BP 132SMG 6 3GBP133270-��K
5.5
M3BP 132SMH 6 3GBP133280-��K
7.5
M3BP 160MLA 6 3GBP163410-��K
11
M3BP 160MLB 6 3GBP163420-��K
15
M3BP 180MLA 6 3GBP183410-��K
18.5
M3BP 200MLA 6 3GBP203410-��K
22
M3BP 200MLB 6 3GBP203420-��K
30
M3BP 225SMA 6 3GBP223210-��K
37
M3BP 250SMA 6 3GBP253210-��K
45
M3BP 280SMB 6 3GBP283220-��K
55
M3BP 280SMC 6 3GBP283230-��K
75
M3BP 315SMC 6 3GBP313230-��K
90
M3BP 315SMD 6 3GBP313240-��K
110
M3BP 315MLB 6 3GBP313420-��K
132
M3BP 315LKA 6 3GBP313810-��K
160
M3BP 355SMB 6 3GBP353220-��K
200
M3BP 355SMC 6 3GBP353230-��K
250
M3BP 355MLB 6 3GBP353420-��K
315
M3BP 355LKA 6 3GBP353810-��K
355
M3BP 355LKB 6 3GBP353820-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 938 81.5 82.8 82.2 969 84.4 84.5 82.8 972 85.8 85.6 83.6 978 87.3 87.5 86.1 977 88.5 88.8 87.5 974 89.4 89.9 89.3 966 89.6 90.4 90.2 980 90.8 91.5 91.0 979 91.2 91.8 91.1 981 92.2 92.5 91.5 990 92.8 93.2 92.6 990 93.3 93.7 93.1 989 94.1 94.7 94.5 991 94.4 94.9 94.7 992 94.7 95.1 94.6 990 95.0 95.4 95.0 994 95.3 95.6 95.2 994 95.5 95.8 95.4 994 95.7 95.9 95.7 993 95.9 96.1 95.9 995 96.1 96.1 95.6 995 96.2 96.4 96.1 995 96.4 96.6 96.5 994 96.5 96.7 96.4 995 96.5 96.6 96.1
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.74 1.8 4.8 7.7
2.4 2.7 0.0072
0.68 2.6 4.1 10.9 1.6 2.2 0.0025
0.64 3.8 4.5 14.7 1.3 2.5 0.0196
0.69 5.1 5.4 21.5 2.0 2.6 0.0416
0.69 6.9 5.9 29
1.4 2.8 0.0416
0.69 9.3 5.6 38.7 2.2 2.8 0.0416
0.73 12.1 5.0 54.1 1.8 2.7 0.0654
0.78 15.2 7.9 73
1.7 3.3 0.114
0.74 23.5 8.5 107 2.2 3.9 0.131
0.77 30.4 5.5 146 1.7 2.7 0.225
0.77 37.3 7.5 178 2.6 3.2 0.448
0.79 43 7.8 212 2.6 3.2 0.531
0.81 56.8 7.9 289 2.8 3.1 0.813
0.83 68 7.7 356 2.7 2.9 1.49
0.85 80.9 6.9 434 2.4 2.6 2.2
0.85 99.4 6.8 506 2.4 2.6 2.85
0.83 138 7.0 721 2.2 2.8 4.9
0.81 170 7.2 864 2.4 2.9 4.9
0.83 202 6.9 1058 2.3 2.7 6.3
0.82 243 6.9 1269 2.4 2.7 7.3
0.82 294 7.0 1536 2.1 2.7 9.7
0.82 367 7.3 1920 2.3 2.8 11.3
0.83 456 7.1 2399 2.3 2.7 13.5
0.83 576 6.9 3026 2.3 2.6 15.5
0.81 668 7.7 3407 2.7 2.9 16.5
Weight kg
Sound
pressure
Level LPA dB
34
44
47
49
53
66
81
57
82
57
82
57
79
57
172
59
198.7 59
234 59
291 63
318 63
392 63
467 63
680 65
725 65
1000 67
1040 67
1200 68
1410 68
1680 73
1820 73
2180 73
2500 76
2600 76
Output kW
Motor type
Product code
1000 r/min = 6 poles
160
M3BP 315LKC 6 3GBP313830-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 994 96.1 96.3 96.2
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.82 297 7.4 1537 2.7 2.9 9.2
Weight kg
Sound
pressure
Level LPA dB
1600 68
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045.
ABB Motors and Generators | 9AKK105944 EN 02-2020
39
Technical data, 460 V 60 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3600 r/min = 2 poles
0.75
M3BP 80MD 2 3GBP081340-��K
1.1
M3BP 80MG 2 3GBP081370-��K
1.5
M3BP 90LB 2 3GBP091520-��K
2.2
M3BP 90LC 2 3GBP091530-��K
3
M3BP 100LKA 2 3GBP101810-��K
4
M3BP 112MG 2 3GBP111370-��K
5.5
M3BP 132SMF 2 3GBP131260-��K
7.5
M3BP 132SMG 2 3GBP131270-��K
11
M3BP 160MLA 2 3GBP161410-��K
15
M3BP 160MLB 2 3GBP161420-��K
18.5
M3BP 160MLC 2 3GBP161430-��K
22
M3BP 180MLA 2 3GBP181410-��K
30
M3BP 200MLA 2 3GBP201410-��K
37
M3BP 200MLB 2 3GBP201420-��K
45
M3BP 225SMA 2 3GBP221210-��K
55
M3BP 250SMA 2 3GBP251210-��K
75
M3BP 280SMB 2 3GBP281220-��K
90
M3BP 280SMC 2 3GBP281230-��K
110
M3BP 315SMB 2 3GBP311220-��K
132
M3BP 315SMC 2 3GBP311230-��K
160
M3BP 315MLA 2 3GBP311410-��K
200 1) M3BP 355SMA 2 3GBP351210-��K
250 1) M3BP 355SMB 2 3GBP351220-��K
315 1) M3BP 355SMC 2 3GBP351230-��K
355 1) M3BP 355MLA 2 3GBP351410-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
3502 3500 3522 3517 3512 3500 3519 3524 3549 3554 3555 3560 3562 3564 3570 3569 3579 3582 3598 3586 3585 3586 3585 3582 3586
460 V 60 Hz 77.0 75.2 84.0 83.0 85.5 85.3 86.5 87.1 88.5 88.7 88.5 88.9 89.5 89.4 90.2 90.7 91.0 91.1 91.0 90.4 93.5 93.6 91.7 91.7 92.4 92.0 93.0 92.8 93.6 93.1 93.6 93.1 94.1 93.4 95.3 94.9 95.3 94.9 95.7 95.4 95.4 94.9 96.1 95.8 95.8 95.3 95.8 95.5 95.8 95.3
70.0 80.2 84.0 85.8 87.3 87.9 88.7 90.0 89.9 89.6 92.7 90.4 90.4 91.1 91.5 91.6 91.6 93.7 93.5 94.2 93.6 94.8 94.0 94.3 94.2
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.72 1.56 8.9 2
4.3 5.2 0.0008
0.78 2.0 9.9 3
3.6 5.3 0.001
0.88 2.4 9.6 4
2.5 4.0 0.0027
0.88 3.5 9.9 5.9
3.2 4.2 0.0032
0.89 4.7 9.9 8.1
3.5 4.6 0.0057
0.90 6.2 10.0 10.9 3.6 4.8 0.0104
0.90 8.4 9.1 14.9 2.5 3.9 0.0154
0.90 11.4 9.6 20.3 3.1 4.5 0.0173
0.91 16.6 8.7 29.54 2.7 3.9 0.057
0.89 22.7 8.5 40.27 3.8 4.8 0.063
0.89 27.9 10.5 49.64 3.8 4.7 0.076
0.89 33 9.2 58.96 4.1 4.7 0.11
0.90 44.9 8.7 80.4 2.8 3.4 0.178
0.89 55.8 9.2 99.1 3.1 3.7 0.196
0.89 67.4 7.8 120 2.8 3.7 0.296
0.90 82.7 7.9 147 2.3 3.3 0.426
0.87 115 7.9 200 2.7 3.4 0.9
0.88 133 9.0 240 3.4 3.4 1.15
0.88 165 7.5 293 1.9 2.9 1.4
0.88 197 8.9 351 2.4 3.3 1.7
0.87 242 8.3 426 2.2 3.1 1.7
0.88 295 8.5 533 2.0 3.4 3
0.89 370 8.6 665 1.8 3.7 3
0.89 466 7.8 839 2.2 3.3 3.4
0.88 528 8.1 945 2.2 3.3 3.6
Weight kg
Sound
pressure
Level LPA dB
18
61
19
60
31
65
35
65
50
65
56
71
77
74
77
73
141
75
170
74
183 75
234 77
289 76
314 76
409 79
452 81
665 74
725 80
940 80
1025 80
1190 81
1600 86
1680 86
1750 86
2000 88
Output kW
Motor type
Product code
3600 r/min = 2 poles
200
M3BP 315MLB 2
250
M3BP 315LKB 2
3GBP311420-��K 3GBP311820-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
3585 3583
460 V 60 Hz 95.8 95.6 96.1 96.1
94.6 95.8
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.88 298 8.7 533 2.6 3.4 2.1
0.91 359 9.0 666 2.6 3.0 2.9
Weight kg
Sound
pressure
Level LPA dB
1220 84 1540 80
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045.
40
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 460 V 60 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1800 r/min = 4 poles
0.55
M3BP 80MLD 4 3GBP082440-��K
0.75
M3BP 90L 4
3GBP092500-��K
1.1
M3BP 90LC 4 3GBP092530-��K
1.5
M3BP 90LD 4 3GBP092540-��K
2.2
M3BP 100LKA 4 3GBP102810-��K
3
M3BP 100LKB 4 3GBP102820-��K
4
M3BP 112MG 4 3GBP112370-��K
5.5
M3BP 132SMF 4 3GBP132260-��K
7.5
M3BP 132SMG 4 3GBP132270-��K
11
M3BP 160MLA 4 3GBP162410-��K
15
M3BP 160MLB 4 3GBP162420-��K
18.5
M3BP 180MLA 4 3GBP182410-��K
22
M3BP 180MLB 4 3GBP182420-��K
30
M3BP 200MLA 4 3GBP202410-��K
37
M3BP 225SMA 4 3GBP222210-��K
45
M3BP 225SMB 4 3GBP222220-��K
55
M3BP 250SMA 4 3GBP252210-��K
75
M3BP 280SMB 4 3GBP282220-��K
90
M3BP 280SMC 4 3GBP282230-��K
110
M3BP 315SMC 4 3GBP312230-��K
132
M3BP 315SMD 4 3GBP312240-��K
160
M3BP 315MLB 4 3GBP312420-��K
200
M3BP 355SMA 4 3GBP352210-��K
250
M3BP 355SMB 4 3GBP352220-��K
315
M3BP 355SMC 4 3GBP352230-��K
355
M3BP 355MLA 4 3GBP352410-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1747 1754 1749 1748 1760 1759 1760 1767 1766 1780 1780 1783 1783 1785 1783 1784 1787 1785 1786 1792 1791 1791 1792 1792 1793 1791
460 V 60 Hz 83.9 84 85.4 84.3 86.5 85.4 86.5 85.1 89.5 89.2 89.5 89.3 89.8 89.7 91.7 91.1 91.7 91.6 92.4 92.2 93.0 92.7 93.6 93.7 93.8 94.2 94.1 94.1 94.5 94.7 95.0 94.9 95.7 95.8 95.4 95.2 95.4 95.2 96.1 96.0 96.4 96.3 96.4 96.4 96.4 96.2 96.2 95.9 96.2 96.0 96.2 96.0
82.1 81.0 82.5 82.0 87.4 87.4 88.3 89.6 90.8 90.9 91.4 93.1 93.7 93.1 94.1 95.0 95.2 94.1 94.2 95.3 95.6 95.9 95.4 95.0 95.1 95.2
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.79 1.03 7.6 3
3.1 4
0.0028
0.76 1.45 9.3 4.1
4.2 5.2 0.0056
0.77 2.0 8.4 6
3.7 4.6 0.0055
0.75 2.9 9.5 8.1
4.0 5.0 0.0055
0.81 3.8 10.2 11.9 3.3 4.7 0.0144
0.81 5.2 10.4 16.3 3.8 4.9 0.0144
0.74 7.6 8.8 21.7 3.8 4.4 0.0176
0.73 10.4 8.7 29.81 3.0 4.5 0.0295
0.79 13 8.7 40.5 2.6 3.9 0.0414
0.80 18.9 8.7 59.14 3.4 3.7 0.11
0.82 24.7 9.5 80.47 3.3 4.1 0.135
0.82 30.3 8.4 99.04 3.1 3.5 0.219
0.82 35.8 9.3 117
3.0 3.4 0.217
0.84 47.7 8.2 161 2.8 3.9 0.385
0.83 59.3 8.8 198 3.6 3.5 0.427
0.83 71.8 8.8 241 2.9 4.7 0.525
0.84 85.8 9.1 293 3.3 3.7 0.933
0.84 117 7.4 401 2.5 3.1 1.38
0.85 139 8.2 481 2.7 3.2 1.73
0.84 172 8.8 586 2.6 3.4 2.9
0.84 206 9.0 704 2.8 3.6 3.2
0.86 241 9.0 853 2.9 3.3 3.9
0.87 301 8.3 1065 2.2 3.0 5.9
0.85 380 7.3 1333 2.2 3.2 5.9
0.86 478 7.6 1679 2.5 3.5 6.9
0.86 541 7.2 1893 2.4 3.1 7.2
Weight kg
Sound
pressure
Level LPA dB
20
48
30
56
33
56
34
58
49
57
49
57
52
62
81
73
81
69
188 68
187
67
235 68
235 66
319
69
398 65
398 72
476 71
665 75
725 75
1000 71
1065 71
1220 71
1610 77
1780 81
1820 81
2140 81
Output kW
Motor type
Product code
1800 r/min = 4 poles
200
M3BP 315LKB 4
250
M3BP 315LKC 4
250
M3BP 315LKC 4
3GBP312820-��K 3GBP312830-��K 3GBP312830-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1788 1791 1791
460 V 60 Hz 96.2 96.2 96.7 96.7 97.0 97.0
95.6 96.4 96.7
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.86 305 7.8 1068 2.6 3.3 3.9
0.86 376 8.9 1332 2.5 3.3 5.5
0.86 376 8.9 1332 2.5 3.3 5.5
Weight kg
Sound
pressure
Level LPA dB
1520 77 1600 77 1600 77
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045.
ABB Motors and Generators | 9AKK105944 EN 02-2020
41
Technical data, 460 V 60 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1200 r/min = 6 poles
0.75
M3BP 90LG 6 3GBP093570-��K
1.1
M3BP 100LKG 6 3GBP103870-��K
1.5
M3BP 112MH 6 3GBP113380-��K
2.2
M3BP 132SMC 6 3GBP133230-��K
3
M3BP 132SMD 6 3GBP133240-��K
4
M3BP 132SMG 6 3GBP133270-��K
5.5
M3BP 132SMH 6 3GBP133280-��K
7.5
M3BP 160MLA 6 3GBP163410-��K
11
M3BP 160MLB 6 3GBP163420-��K
15
M3BP 180MLA 6 3GBP183410-��K
18.5
M3BP 200MLA 6 3GBP203410-��K
22
M3BP 200MLB 6 3GBP203420-��K
30
M3BP 225SMA 6 3GBP223210-��K
37
M3BP 250SMA 6 3GBP253210-��K
45
M3BP 280SMB 6 3GBP283220-��K
55
M3BP 280SMC 6 3GBP283230-��K
75
M3BP 315SMC 6 3GBP313230-��K
90
M3BP 315SMD 6 3GBP313240-��K
110
M3BP 315MLB 6 3GBP313420-��K
132
M3BP 315LKA 6 3GBP313810-��K
160
M3BP 355SMB 6 3GBP353220-��K
200
M3BP 355SMC 6 3GBP353230-��K
250
M3BP 355MLB 6 3GBP353420-��K
315
M3BP 355LKA 6 3GBP353810-��K
355
M3BP 355LKB 6 3GBP353820-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1146 1171 1174 1180 1179 1177 1169 1182 1183 1183 1191 1191 1191 1192 1193 1190 1195 1195 1194 1194 1195 1196 1195 1195 1195
460 V 60 Hz 83.4 83.4 88.0 88.0 89.4 89.0 90.1 89.6 90.1 89.7 90.1 90.0 91.0 91.2 91.4 91.5 91.7 91.8 92.3 92.0 93.3 93.2 93.8 93.8 94.2 94.3 94.5 94.7 95.3 95.2 95.3 95.3 96.3 96.1 95.7 95.6 96.1 96.0 96.1 96.0 96.1 96.0 96.1 95.7 96.4 96.4 96.4 96.4 96.4 96.1
81.2 86.4 87.1 87.6 87.9 88.6 90.3 90.3 90.5 90.5 92.1 92.8 93.6 94.1 94.3 94.5 95.4 94.9 95.4 95.5 95.3 95.0 95.8 95.8 95.3
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.72 1.6 5.5 6.3
2.6 3.2 0.0072
0.66 2.3 4.6 9
1.3 2.7 0.0025
0.62 3.4 7.5 12.2 3.0 5.2 0.0196
0.68 4.5 6.5 17.8 2.1 3.3 0.0416
0.68 6.1 6.5 24
1.4 3.1 0.0416
0.68 8.1 6.3 32
2.3 3.2 0.0416
0.72 10.6 5.7 44.7 2.0 3.1 0.0654
0.76 13.5 8.6 60.5 1.8 3.7 0.114
0.73 20.6 9.4 88.7 2.3 4.4 0.131
0.75 27.1 6.0 121 1.8 3.1 0.225
0.77 32.3 8.6 148 2.9 3.6 0.448
0.78 37.7 8.8 176 2.9 3.6 0.531
0.80 49.9 8.9 240 3.2 3.5 0.813
0.82 59.9 8.6 296 3.0 3.2 1.49
0.85 70.6 7.9 361 2.6 2.9 2.2
0.85 86.2 7.8 420 2.6 2.9 2.85
0.82 121 7.9 600 2.5 3.1 4.9
0.80 149 8.2 719 2.7 3.2 4.9
0.81 177 7.9 880 2.6 3.0 6.3
0.81 215 7.9 1055 2.7 3.0 7.3
0.81 260 7.9 1278 2.3 3.0 9.7
0.82 320 8.3 1598 2.5 3.1 11.3
0.82 401 9.2 1997 2.3 3.0 13.5
0.83 500 7.9 2516 2.6 2.9 15.5
0.80 584 8.8 2835 3.0 3.2 16.5
Weight kg
Sound
pressure
Level LPA dB
34
47
47
52
53
69
81
60
82
60
82
60
79
60
172
63
198.7 63
234 63
291 67
318 67
392 67
467 67
680 68
725 68
1000 70
1040 70
1200 71
1410 71
1680 76
1820 76
2180 76
2500 79
2600 79
Output kW
Motor type
Product code
1200 r/min = 6 poles
160
M3BP 315LKC 6 3GBP313830-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
460 V 60 Hz 1195 96.1 96.0 95.3
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.81 259 8.4 1279 3.0 3.2 9.2
Weight kg
Sound
pressure
Level LPA dB
1600 71
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045.
42
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3000 r/min = 2 poles
0.55
M3BP 71ME 2 3GBP071350-��L
0.75
M3BP 80MC 2 3GBP081330-��L
1.1
M3BP 80ME 2 3GBP081350-��L
1.5
M3BP 90SLA 2 3GBP091010-��L
2.2
M3BP 90LA 2 3GBP091510-��L
3
M3BP 100MLA 2 3GBP101410-��L
4
M3BP 112ME 2 3GBP111350-��L
5.5
M3BP 132SMC 2 3GBP131230-��L
7.5
M3BP 132SME 2 3GBP131250-��L
11
M3BP 160MLA 2 3GBP161410-��L
15
M3BP 160MLB 2 3GBP161420-��L
18.5
M3BP 160MLC 2 3GBP161430-��L
22
M3BP 180MLA 2 3GBP181410-��L
30
M3BP 200MLA 2 3GBP201410-��L
37
M3BP 200MLB 2 3GBP201420-��L
45
M3BP 225SMA 2 3GBP221210-��L
55
M3BP 250SMA 2 3GBP251210-��L
75
M3BP 280SMB 2 3GBP281220-��L
90
M3BP 280SMC 2 3GBP281230-��L
110
M3BP 315SMB 2 3GBP311220-��L
132
M3BP 315SMC 2 3GBP311230-��L
160
M3BP 315SMD 2 3GBP311240-��L
200
M3BP 315MLA 2 3GBP311410-��L
250 1) M3BP 355SMA 2 3GBP351210-��L
315 1) M3BP 355SMB 2 3GBP351220-��L
355 1) M3BP 355SMC 2 3GBP351230-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
2755 2894 2883 2906 2900 2896 2888 2901 2909 2943 2947 2949 2943 2956 2959 2968 2968 2977 2976 2982 2982 2983 2983 2985 2980 2984
400 V 50 Hz 77.8 79.3 80.7 80.4 82.7 82.4 84.2 84.7 85.9 87.5 87.1 88.2 88.1 89.4 89.2 89.9 90.1 91.2 91.2 91.9 91.9 92.2 92.4 92.9 93.0 93.7 93.3 93.7 93.7 93.9 94.0 94.0 94.3 93.7 94.7 94.2 95.0 95.1 95.2 94.9 95.4 95.1 95.6 95.6 95.8 95.8 95.8 95.6 95.8 95.7 95.8 95.8
78.4 77.2 80.6 84.6 87.6 88.0 89.6 90.1 91.4 91.6 91.8 92.6 93.6 93.0 93.2 93.1 93.6 92.8 94.3 93.9 94.0 94.9 95.3 94.6 95.0 95.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.83 1.25 6.8 1.9
2.8 3.1 0.00045
0.74 1.7 7.9 2.4
3.7 4.2 0.0008
0.81 2.3 7.9 3.6
3.7 4.2 0.001
0.89 2.8 7.9 4.9
2.3 3.3 0.0027
0.89 4.0 8.3 7.2
2.9 3.5 0.0032
0.90 5.4 8.4 9.8
3.2 3.9 0.0057
0.91 7.1 8.4 13.2 3.2 4.0 0.0104
0.91 9.7 7.9 18.1 2.3 3.4 0.0154
0.90 13.1 8.3 24.6 3.0 3.9 0.0173
0.91 19.1 7.2 35.57 2.6 3.6 0.057
0.88 26.5 8.2 48.49 3.2 4.2 0.063
0.90 32 9.0 59.81 3.3 3.9 0.076
0.93 36.8 6.7 70.98 2.0 2.9 0.11
0.90 51.6 7.7 96.9 2.7 3.1 0.178
0.90 63.5 8.2 119 3.0 3.3 0.196
0.87 79.6 7.2 145 2.5 3.1 0.296
0.89 94.8 6.8 177
2.4 3.0 0.426
0.88 131 7.6 240 2.1 3.0 0.8
0.89 154 7.4 288 2.1 2.9 0.9
0.87 192 7.0 352 1.8 2.7 1.3
0.88 227 7.4 422 2.2 3.0 1.4
0.87 275 7.4 512 2.2 2.8 1.7
0.88 342 7.7 640 2.5 3.1 2.1
0.89 423 7.7 800 2.1 3.3 3
0.89 529 7.0 1009 2.1 3.0 3.4
0.88 605 7.2 1136 2.2 3.0 3.6
Weight kg
Sound
pressure
Level LPA dB
11
56
17
57
18
56
27
60
30
60
42
62
56
68
69
68
75
70
144 69
152
69
164 73
205 73
263 72
289 72
335 76
400 76
665 77
690 77
910 78
965 78
1025 78
1190 81
1600 83
1680 83
1750 83
Output kW
Motor type
Product code
3000 r/min = 2 poles
22
M3BP 160MLD 2 3GBP161440-��L
30
M3BP 180MLB 2 3GBP181420-��L
37
M3BP 180MLC 2 3GBP181430-��L
45
M3BP 200MLC 2 3GBP201430-��L
55
M3BP 225SMB 2 3GBP221220-��L
75
2) M3BP 225SMC 2 3GBP221230-��L
75
M3BP 250SMB 2 3GBP251220-��L
90
2) M3BP 250SMC 2 3GBP251230-��L
110
M3BP 280SMD 2 3GBP281240-��L
250
M3BP 315LKB 2 3GBP311820-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
2944 2957 2952 2955 2966 2966 2971 2968 2977 2983
400 V 50 Hz 92.7 93.5 93.3 94.0 93.7 94.5 94.0 94.5 94.3 94.6 94.7 94.8 94.7 95.1 95.0 95.4 95.2 95.2 95.8 96.0
93.5 93.9 94.5 94.4 94.1 94.1 94.8 95.0 94.4 95.5
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.90 38 8.4 71.36 3.2 3.7 0.071
0.88 52.7 8.7 96.88 3.0 3.8 0.104
0.88 64.7 8.7 120 3.1 3.7 0.115
0.89 77.6 8.0 145 2.9 3.3 0.214
0.88 95.6 7.4 177
2.9 2.9 0.274
0.88 129 8.1 241 3.3 3.0 0.329
0.90 127 7.9 241 2.8 3.3 0.644
0.90 151 8.4 290 2.7 3.4 0.644
0.88 190 7.5 353 2.4 3.1 1.15
0.90 419 7.7 800 2.5 3.3 2.9
Weight kg
Sound
pressure
Level LPA dB
174
74
215
74
229 74
305 77
355 79
408 79
479 81
495 81
725 75
1540 81
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2
ABB Motors and Generators | 9AKK105944 EN 02-2020
43
Technical data, 400 V 50 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1500 r/min = 4 poles
0.25
M3BP 71MD 4 3GBP072340-��L
0.37
M3BP 71MLE 4 3GBP072450-��L
0.55
M3BP 80MLC 4 3GBP082430-��L
0.75
M3BP 80MLE 4 3GBP082450-��L
1.1
M3BP 90LA 4 3GBP092510-��L
1.5
M3BP 90LB 4 3GBP092520-��L
2.2
M3BP 100LA 4 3GBP102510-��L
3
M3BP 100MLB 4 3GBP102420-��L
4
M3BP 112ME 4 3GBP112350-��L
5.5
M3BP 132SMB 4 3GBP132220-��L
7.5
M3BP 132SME 4 3GBP132250-��L
11
M3BP 160MLA 4 3GBP162410-��L
15
M3BP 160MLB 4 3GBP162420-��L
18.5
M3BP 180MLA 4 3GBP182410-��L
22
M3BP 180MLB 4 3GBP182420-��L
30
M3BP 200MLA 4 3GBP202410-��L
37
M3BP 225SMA 4 3GBP222210-��L
45
M3BP 225SMB 4 3GBP222220-��L
55
M3BP 250SMA 4 3GBP252210-��L
75
M3BP 280SMB 4 3GBP282220-��L
90
M3BP 280SMC 4 3GBP282230-��L
110
M3BP 315SMB 4 3GBP312220-��L
132
M3BP 315SMC 4 3GBP312230-��L
160
M3BP 315SMD 4 3GBP312240-��L
200
M3BP 315MLB 4 3GBP312420-��L
315
M3BP 355SMB 4 3GBP352220-��L
355
M3BP 355SMC 4 3GBP352230-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1416 1432 1444 1448 1437 1445 1455 1445 1451 1460 1462 1477 1477 1481 1481 1483 1482 1482 1482 1485 1485 1489 1488 1488 1487 1491 1490
400 V 50 Hz 73.5 75.1 77.3 77.4 80.8 81.6 82.5 82.5 84.1 83.7 85.3 85.0 86.7 86.6 87.7 88.2 88.6 89.4 89.6 90.1 90.4 91.0 91.4 91.8 92.1 92.3 92.6 93.2 93.0 93.5 93.6 93.9 93.9 94.1 94.2 94.4 94.6 94.7 95.0 95.2 95.2 95.5 95.4 95.5 95.6 95.9 95.8 96.0 96.0 96.4 96.0 96.1 96.0 96.2
73.8 74.5 80.1 80.1 81.2 82.7 84.6 87.6 89.0 89.6 90.3 91.1 91.6 92.9 93.3 93.4 93.8 94.0 94.1 94.8 95.2 95.0 95.5 95.8 96.4 95.7 95.8
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.80 0.6 4.8 1.68 2.0 2.6 0.0009
0.76 0.9 5.8 2.46 2.7 3.3 0.00122
0.80 1.2 6.7 4
3.0 3.5 0.0028
0.78 1.7 7.4 4.9
3.5 4.0 0.0033
0.78 2.46 8.0 7.32 3.3 3.8 0.007
0.75 3.34 7.6 9.95 3.4 4.1 0.007
0.80 4.6 7.9 14.4 3.2 4.0 0.011
0.83 5.9 7.7 19.8 2.8 3.5 0.014
0.77 8.6 7.6 26.3 3.1 4.1 0.018
0.82 11 6.6 35.9 2.2 3.3 0.031
0.79 15.6 6.7 48.9 2.5 3.4 0.037
0.82 21.1 7.6 71.27 2.6 3.3 0.11
0.82 28.5 8.2 96.99 3.0 3.7 0.135
0.83 34.9 7.2 119 2.8 3.0 0.219
0.82 41.4 8.3 142 3.0 3.2 0.243
0.84 54.8 7.5 193 2.7 3.2 0.385
0.83 68.9 7.2 239 3.1 3.1 0.427
0.84 82.3 8.0 290 3.2 3.5 0.525
0.84 100 7.1 354 2.9 3.4 0.694
0.86 133 6.4 483 2.3 2.8 1.38
0.86 158 7.1 578 2.5 2.9 1.73
0.84 198 7.0 705 2.1 3.0 2.43
0.86 231 6.7 847 2.2 2.9 2.9
0.85 282 6.9 1026 2.2 3.0 3.2
0.86 351 6.8 1284 2.4 3.0 3.9
0.85 550 7.3 2018 2.4 3.3 6.9
0.86 616 6.3 2273 2.3 2.8 7.2
Weight kg
Sound
pressure
Level LPA dB
11
45
15
45
20
45
22
50
28
50
32
50
38
54
42
63
52
64
68
66
78
63
160 61
179
61
215
60
229 60
292 63
322 67
357 66
406 68
645 75
700 75
930 71
1000 71
1065 71
1220 74
1780 78
1820 78
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2
44
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1500 r/min = 4 poles
18.5
M3BP 160MLC 4 3GBP162430-��L
30
M3BP 180MLC 4 3GBP182430-��L
37
M3BP 200MLB 4 3GBP202420-��L
55
M3BP 225SMC 4 3GBP222230-��L
75
M3BP 250SMB 4 3GBP252220-��L
110
M3BP 280SMD 4 3GBP282240-��L
132
M3BP 280MLA 4 3GBP282410-��L
160
M3BP 280MLB 4 3GBP282420-��L
280
M3BP 315LKB 4 3GBP312820-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1473 1476 1480 1478 1482 1486 1483 1484 1488
400 V 50 Hz 92.6 93.3 93.6 94.1 93.9 94.8 94.6 94.9 95.0 95.4 95.4 95.7 95.6 95.9 95.8 96.0 96.0 96.2
93.1 94.1 94.8 94.8 95.0 95.3 95.7 95.8 96.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.82 35.1 8.3 120 3.1 3.5 0.124
0.82 56.5 7.4 195 2.5 3.2 0.191
0.82 69.3 7.5 239 2.8 2.9 0.362
0.84 99.9 7.7 355 3.3 3.3 0.536
0.84 135 7.9 483 3.3 3.5 0.941
0.85 196 7.3 707 2.7 3.0 1.95
0.86 232 7.0 849 2.7 2.8 2.3
0.86 280 7.4 1029 2.9 2.9 2.5
0.86 490 7.8 1797 2.7 3.1 5
Weight kg
Sound
pressure
Level LPA dB
180 67 235 62 305 68 391 71 464 73 750 76 840 75 890 75 1520 78
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2
ABB Motors and Generators | 9AKK105944 EN 02-2020
45
Technical data, 400 V 50 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1000 r/min = 6 poles
0.25
M3BP 80MB 6 3GBP083320-��L
0.75
M3BP 90SLD 6 3GBP093040-��L
1.1
M3BP 90LF 6 3GBP093560-��L
1.5
M3BP 100MLB 6 3GBP103420-��L
2.2
M3BP 112MJ 6 3GBP113390-��L
3
M3BP 132SMB 6 3GBP133220-��L
4
M3BP 132SMF 6 3GBP133260-��L
5.5
M3BP 132SMJ 6 3GBP133290-��L
7.5
M3BP 160MLA 6 3GBP163410-��L
11
M3BP 160MLB 6 3GBP163420-��L
15
M3BP 180MLA 6 3GBP183410-��L
18.5
M3BP 200MLA 6 3GBP203410-��L
22
M3BP 200MLB 6 3GBP203420-��L
30
M3BP 225SMA 6 3GBP223210-��L
37
M3BP 250SMA 6 3GBP253210-��L
45
M3BP 280SMB 6 3GBP283220-��L
55
M3BP 280SMC 6 3GBP283230-��L
75
M3BP 315SMB 6 3GBP313220-��L
90
M3BP 315SMC 6 3GBP313230-��L
110
M3BP 315SMD 6 3GBP313240-��L
132
M3BP 315MLB 6 3GBP313420-��L
160
M3BP 355SMA 6 3GBP353210-��L
200
M3BP 355SMB 6 3GBP353220-��L
250
M3BP 355SMC 6 3GBP353230-��L
315
M3BP 355MLB 6 3GBP353420-��L
355
M3BP 355LKA 6 3GBP353810-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 942 68.6 67.0 61.7 940 78.9 80.3 79.2 944 81.0 81.7 80.1 960 82.5 82.5 80.1 962 84.3 85.5 84.7 973 85.6 85.1 82.9 971 86.8 86.5 84.7 966 88.0 89.1 88.9 975 89.1 90.0 90.0 975 90.3 91.2 91.1 979 91.2 91.9 91.6 989 91.7 91.9 91.3 989 92.2 92.4 91.5 988 92.9 93.0 92.2 990 93.3 93.7 93.5 991 93.7 94.0 93.5 992 94.1 94.3 93.8 994 94.6 94.9 94.6 994 94.9 95.1 94.7 994 95.1 95.3 95.0 995 95.4 95.5 95.1 993 95.6 95.8 95.6 993 95.8 96.2 96.1 993 95.8 96.1 95.8 993 95.8 96.1 96.0 993 95.8 96.0 95.9
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.61 0.82 4.8 2.5
2.7 2.9 0.0019
0.75 1.8 4.4 7.57 2.1 2.8 0.0056
0.75 2.62 4.7 11.1 2.1 2.8 0.0068
0.68 3.8 5.4 14.9 2.7 3.4 0.012
0.68 5.3 5.9 21.8 2.3 3.3 0.0196
0.62 8.0 6.6 29.2 2.7 3.8 0.0355
0.62 10.7 6.6 39
2.7 3.8 0.0416
0.73 12.3 4.2 54
1.7 2.7 0.0408
0.77 15.7 5.7 73.24 1.4 3.0 0.089
0.78 22.5 6.4 108 1.6 3.1 0.138
0.79 30.1 5.2 147 1.5 2.7 0.212
0.82 35.2 6.5 179 2.2 3.2 0.496
0.81 42.4 7.3 212 2.6 3.5 0.585
0.77 60.4 7.7 291 2.9 3.6 0.724
0.80 71.1 6.5 357 2.4 3.1 1.3
0.84 82 7.4 433 2.7 3.0 1.87
0.86 99 7.5 528 2.8 3.0 2.57
0.84 136 6.8 720 1.8 2.6 4.1
0.84 164 7.2 864 2.0 3.0 4.6
0.83 200 7.3 1056 2.2 3.1 4.9
0.82 242 7.3 1266 2.3 3.2 6.3
0.82 292 6.7 1538 2.5 2.6 7.9
0.82 365 6.7 1923 2.6 2.5 9.7
0.81 465 7.7 2404 3.0 3.1 11.3
0.83 571 6.8 3029 2.6 3.2 13.5
0.81 653 7.5 3413 2.9 3.2 15.5
Weight kg
Sound
pressure
Level LPA dB
14
47
29
53
33
44
41
49
53
66
75
57
82
57
81
57
146 59
180 64
212
63
272 59
297 59
349 63
431 58
645 72
725 71
930 75
1000 76
1040 75
1200 72
1520 75
1680 75
1820 75
2180 76
2500 76
Output kW
Motor type
Product code
1000 r/min = 6 poles
18.5
M3BP 180MLB 6 3GBP183420-��L
37
M3BP 225SMB 6 3GBP223220-��L
45
M3BP 250SMB 6 3GBP253220-��L
55
M3BP 250SMC 6 3GBP253230-��L
75
M3BP 280SMD 6 3GBP283240-��L
160
M3BP 315LKA 6 3GBP313810-��L
180
M3BP 315LKB 6 3GBP313820-��L
200
M3BP 315LKC 6 3GBP313830-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 980 91.7 92.5 92.0 985 93.3 93.7 93.4 991 93.7 94.1 93.6 989 94.1 94.7 94.5 991 94.6 94.9 94.5 994 95.6 95.8 95.4 994 95.8 95.9 95.4 993 95.8 96.1 95.8
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.75 38.8 6.4 180 2.1 3.1 0.22
0.80 71.5 7.0 359 2.7 3.0 0.813
0.81 85.5 7.6 434 2.9 3.3 1.5
0.80 105 7.1 531 3.0 3.1 1.49
0.85 135 7.6 723 2.8 3.0 3.0
0.81 298 7.5 1535 2.2 3.1 7.3
0.82 331 7.6 1729 2.3 3.1 8.3
0.82 367 7.0 1923 2.2 2.8 9.2
Weight kg
Sound
pressure
Level LPA dB
219
65
382 68
465 68
466 68
740 73
1410 76
1520 76
1600 76
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2
46
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 460 V 60 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3600 r/min = 2 poles
0.55
M3BP 71ME 2 3GBP071350-��L
0.75
M3BP 80MC 2 3GBP081330-��L
1.1
M3BP 80ME 2 3GBP081350-��L
1.5
M3BP 90SLA 2 3GBP091010-��L
2.2
M3BP 90LA 2 3GBP091510-��L
3
M3BP 100MLA 2 3GBP101410-��L
4
M3BP 112ME 2 3GBP111350-��L
5.5
M3BP 132SMC 2 3GBP131230-��L
7.5
M3BP 132SME 2 3GBP131250-��L
11
M3BP 160MLA 2 3GBP161410-��L
15
M3BP 160MLB 2 3GBP161420-��L
18.5
M3BP 160MLC 2 3GBP161430-��L
22
M3BP 180MLA 2 3GBP181410-��L
30
M3BP 200MLA 2 3GBP201410-��L
37
M3BP 200MLB 2 3GBP201420-��L
45
M3BP 225SMA 2 3GBP221210-��L
55
M3BP 250SMA 2 3GBP251210-��L
75
3) M3BP 280SMB 2 3GBP281220-��L
90
3) M3BP 280SMC 2 3GBP281230-��L
110
M3BP 315SMB 2 3GBP311220-��L
132 3) M3BP 315SMC 2 3GBP311230-��L
160
M3BP 315SMD 2 3GBP311240-��L
200
M3BP 315MLA 2 3GBP311410-��L
250 1) M3BP 355SMA 2 3GBP351210-��L
315 1) M3BP 355SMB 2 3GBP351220-��L
355 1) M3BP 355SMC 2 3GBP351230-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
3386 3502 3500 3522 3517 3512 3500 3519 3524 3549 3554 3555 3560 3562 3564 3570 3569 3579 3578 3584 3584 3585 3585 3586 3583 3585
460 V 60 Hz 76.8 76.7 77.0 75.2 84.0 83.0 85.5 85.3 86.5 87.1 88.5 88.7 88.5 88.9 89.5 89.4 90.2 90.7 91.0 91.1 91.0 90.3 91.7 91.8 91.7 91.7 92.3 92.0 92.9 92.7 93.6 93.2 93.6 93.1 93.0 92.4 93.7 93.2 95.0 94.3 94.1 93.5 95.4 94.9 95.8 95.6 95.8 95.2 95.8 95.4 95.8 95.4
74.0 70.0 80.2 84.0 85.8 87.3 87.9 88.7 90.0 89.9 89.5 90.7 90.3 90.4 91.0 91.5 91.7 90.5 91.7 92.7 91.7 93.6 94.6 93.5 94.2 94.2
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.81 1.1 8.4 1.55 3.3 3.9 0.00045
0.72 1.56 8.9 2
4.3 5.2 0.0008
0.78 2
9.9 3
4.4 5.3 0.001
0.88 2.4 9.6 4
2.5 4.0 0.0027
0.88 3.5 9.9 5.9
3.2 4.2 0.0032
0.89 4.7 9.9 8.1
3.5 4.6 0.0057
0.90 6.2 10.0 10.9 3.6 4.8 0.0104
0.90 8.4 9.1 14.9 2.5 3.9 0.0154
0.90 11.4 9.6 20.3 3.1 4.5 0.0173
0.91 16.6 8.7 29.5 2.7 3.9 0.057
0.89 22.7 8.5 40.3 3.8 4.8 0.063
0.89 27.9 10.5 49.6 3.8 4.7 0.076
0.89 33 9.2 59.0 4.1 4.7 0.11
0.90 44.9 8.7 80.4 2.8 3.4 0.178
0.89 55.8 9.2 99.1 3.1 3.7 0.196
0.89 67.4 7.8 120 2.7 3.7 0.296
0.90 82.7 7.9 147 2.3 3.3 0.426
0.87 116 8.5 199 2.1 3.3 0.8
0.89 135 8.3 239 2.2 3.2 0.9
0.87 168 7.8 293 1.8 3.0 1.3
0.88 200 8.3 351 2.2 3.3 1.4
0.87 242 8.3 426 2.2 3.1 1.7
0.88 298 8.7 533 2.6 3.4 2.1
0.89 373 8.6 666 2.1 3.7 3
0.89 465 7.9 840 2.2 3.3 3.4
0.88 527 8.1 946 2.2 3.3 3.6
Weight kg
Sound
pressure
Level LPA dB
11
59
17
61
18
60
27
65
30
65
42
65
56
71
69
74
75
73
144 75
152
74
164 75
205 77
263 76
289 76
335 79
400 81
665 77
690 82
910 81
965 83
1025 81
1190 84
1600 86
1680 86
1750 86
Output kW
Motor type
Product code
3600 r/min = 2 poles
22
M3BP 160MLD 2 3GBP161440-��L
30
M3BP 180MLB 2 3GBP181420-��L
37
M3BP 180MLC 2 3GBP181430-��L
45
M3BP 200MLC 2 3GBP201430-��L
55
M3BP 225SMB 2 3GBP221220-��L
75
M3BP 225SMC 2 3GBP221230-��L
75
M3BP 250SMB 2 3GBP251220-��L
90
M3BP 250SMC 2 3GBP251230-��L
110
M3BP 280SMD 2 3GBP281240-��L
250
M3BP 315LKB 2 3GBP311820-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
3552 3563 3560 3562 3571 3571 3575 3573 3580 3585
460 V 60 Hz 91.7 92.0 93.3 93.5 93.0 93.3 93.6 94.0 93.6 93.5 94.1 94.0 94.1 94.1 95.0 95.0 95.0 94.7 95.8 95.6
91.2 92.9 92.7 93.4 92.3 93.0 93.1 94.0 93.4 94.7
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.90 32.9 9.7 59.2 3.5 4.2 0.071
0.88 45.7 10.0 80.4 3.3 4.3 0.104
0.88 56.1 10.0 99.3 3.4 4.2 0.115
0.89 67.2 9.1 121 3.1 3.7 0.214
0.89 82.1 8.5 147 3.0 3.2 0.274
0.89 111 9.3 201 3.4 3.4 0.329
0.90 110 9.0 200 3.0 3.6 0.644
0.90 132 9.5 241 2.8 3.7 0.644
0.88 166 8.5 293 2.5 3.4 1.15
0.90 364 8.8 666 2.6 3.7 2.9
Weight kg
Sound
pressure
Level LPA dB
174
78
215
78
229 78
305 81
355 83
408 83
479 85
495 85
725 78
1540 84
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2
ABB Motors and Generators | 9AKK105944 EN 02-2020
47
Technical data, 460 V 60 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1800 r/min = 4 poles
0.25
M3BP 71MD 4 3GBP072340-��L
0.37
M3BP 71MLE 4 3GBP072450-��L
0.55
M3BP 80MLC 4 3GBP082430-��L
0.75
M3BP 80MLE 4 3GBP082450-��L
1.1
4) M3BP 90LA 4 3GBP092510-��L
1.5
4) M3BP 90LB 4
3GBP092520-��L
2.2 3) M3BP 100LA 4 3GBP102510-��L
3
4) M3BP 100MLB 4 3GBP102420-��L
4
M3BP 112ME 4 3GBP112350-��L
5.5 4) M3BP 132SMB 4 3GBP132220-��L
7.5
4) M3BP 132SME 4 3GBP132250-��L
11
M3BP 160MLA 4 3GBP162410-��L
15
M3BP 160MLB 4 3GBP162420-��L
18.5
M3BP 180MLA 4 3GBP182410-��L
22
M3BP 180MLB 4 3GBP182420-��L
30
M3BP 200MLA 4 3GBP202410-��L
37
M3BP 225SMA 4 3GBP222210-��L
45
M3BP 225SMB 4 3GBP222220-��L
55
M3BP 250SMA 4 3GBP252210-��L
75
4) M3BP 280SMB 4 3GBP282220-��L
90
M3BP 280SMC 4 3GBP282230-��L
110
M3BP 315SMB 4 3GBP312220-��L
132 4) M3BP 315SMC 4 3GBP312230-��L
160 4) M3BP 315SMD 4 3GBP312240-��L
200
M3BP 315MLB 4 3GBP312420-��L
315
M3BP 355SMB 4 3GBP352220-��L
355
M3BP 355SMC 4 3GBP352230-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1727 1740 1749 1753 1743 1751 1760 1748 1755 1763 1765 1777 1780 1783 1784 1785 1783 1784 1785 1785 1786 1791 1790 1790 1788 1792 1791
460 V 60 Hz 73.4 73.4 78.2 77.5 81.1 80.7 83.5 82.9 84.7 83.7 86.4 85.5 86.9 86.1 87.8 87.6 90.1 90.5 90.4 90.3 91.4 91.4 92.4 92.2 93.0 92.7 93.6 93.7 93.6 93.7 94.1 94.1 94.5 94.7 95.0 94.9 95.4 95.2 94.5 94.2 95.4 95.2 95.8 95.5 95.0 94.9 95.0 94.8 96.2 96.2 96.2 96.0 96.2 96.0
70.4 74.4 77.6 79.8 80.6 82.6 83.5 85.9 89.5 88.9 90.2 91.0 91.4 93.1 93.2 93.1 94.0 95.0 94.2 93.0 94.2 94.4 94.1 93.8 95.6 95.1 95.2
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.77 0.53 5.8 1.38 2.4 3.2 0.0009
0.73 0.81 6.9 2.02 3.1 4.0 0.00122
0.78 1.1 8.0 3.3
3.5 4.3 0.0028
0.76 1.45 8.8 4.05 3.3 4.9 0.0033
0.75 2.2 9.3 6.02 3.7 4.6 0.007
0.73 3.02 8.8 8.21 4.1 4.9 0.007
0.78 4.07 9.3 11.9 3.6 4.8 0.011
0.83 5.17 9.1 16.4 3.1 4.2 0.014
0.75 7.43 9.3 21.7 3.5 4.9 0.018
0.79 9.67 7.5 29.7 2.4 3.8 0.031
0.76 13.6 7.7 40.5 2.7 3.9 0.037
0.82 18.2 8.7 59.1 2.9 4.2 0.11
0.82 24.7 9.5 80.5 3.3 4.1 0.135
0.82 30.3 8.4 99
3.1 3.5 0.219
0.82 35.8 9.3 117
3.3 3.7 0.243
0.84 47.7 8.2 161 2.8 3.9 0.385
0.83 59.3 8.8 198 3.6 3.5 0.427
0.83 71.8 8.8 241.2 2.9 4.7 0.525
0.83 87.5 7.9 294.3 3.2 4.4 0.694
0.84 117 7.4 401 2.5 3.1 1.38
0.85 139 8.2 481 2.7 3.2 1.73
0.84 172 7.9 587 2.2 3.3 2.43
0.85 204 7.6 705 2.4 3.2 2.9
0.85 246 7.8 854 2.4 3.3 3.2
0.86 305 7.8 1068 2.6 3.3 3.9
0.87 494 7.5 1679 2.2 3.5 6.9
0.86 541 7.2 1893 2.4 3.1 7.2
Weight kg
Sound
pressure
Level LPA dB
11
48
15
48
20
48
22
53
28
53
32
53
38
57
42
66
52
67
68
69
78
66
160 68
179
67
215
68
229 67
292 69
322 65
357 72
406 73
645 77
700 78
930 74
1000 74
1065 74
1220 77
1780 81
1820 81
Output kW
Motor type
Product code
1800 r/min = 4 poles
18.5 4) M3BP 160MLC 4 3GBP162430-��L
30
M3BP 180MLC 4 3GBP182430-��L
37
M3BP 200MLB 4 3GBP202420-��L
55
4) M3BP 225SMC 4 3GBP222230-��L
75
M3BP 250SMB 4 3GBP252220-��L
110
M3BP 280SMD 4 3GBP282240-��L
132 4) M3BP 280MLA 4 3GBP282410-��L
160 4) M3BP 280MLB 4 3GBP282420-��L
280 4) M3BP 315LKB 4 3GBP312820-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1777 1780 1783 1782 1784 1788 1785 1786 1789
460 V 60 Hz 92.4 92.6 94.3 94.5 94.5 94.9 94.1 94.4 95.4 95.4 95.8 95.9 95.7 95.7 96.0 96.0 95.8 95.6
91.5 93.9 94.4 93.6 94.6 95.3 95.4 95.4 94.9
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.80 31.2 9.2 99.4 3.3 3.9 0.124
0.81 49 8.5 161 2.9 3.7 0.191
0.82 59.9 8.6 198 3.1 3.3 0.362
0.84 86.7 8.7 295 3.4 3.6 0.536
0.84 117 9.1 401 3.6 4.0 0.941
0.84 171 8.4 588 2.9 3.3 1.95
0.86 202 8.1 705 2.9 3.1 2.3
0.86 242 9.1 855 3.1 3.2 2.5
0.84 437 9.2 1494 3.2 3.4 5
Weight kg
Sound
pressure
Level LPA dB
180 71 235 65 305 68 391 75 464 77 750 80 840 78 890 78 1520 81
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2
48
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 460 V 60 Hz
IE3 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1200 r/min = 6 poles
0.75
M3BP 90SLD 6 3GBP093040-��L
1.1
3) M3BP 90LF 6
3GBP093560-��L
1.5
3) M3BP 100MLB 6 3GBP103420-��L
2.2 4) M3BP 112MJ 6 3GBP113390-��L
3
4) M3BP 132SMB 6 3GBP133220-��L
4
4) M3BP 132SMF 6 3GBP133260-��L
5.5
M3BP 132SMJ 6 3GBP133290-��L
7.5
M3BP 160MLA 6 3GBP163410-��L
11
M3BP 160MLB 6 3GBP163420-��L
15
M3BP 180MLA 6 3GBP183410-��L
18.5
M3BP 200MLA 6 3GBP203410-��L
22
M3BP 200MLB 6 3GBP203420-��L
30
4) M3BP 225SMA 6 3GBP223210-��L
37
M3BP 250SMA 6 3GBP253210-��L
45
M3BP 280SMB 6 3GBP283220-��L
55
M3BP 280SMC 6 3GBP283230-��L
75
M3BP 315SMB 6 3GBP313220-��L
90
M3BP 315SMC 6 3GBP313230-��L
110 4) M3BP 315SMD 6 3GBP313240-��L
132
M3BP 315MLB 6 3GBP313420-��L
160
M3BP 355SMA 6 3GBP353210-��L
200
M3BP 355SMB 6 3GBP353220-��L
250
M3BP 355SMC 6 3GBP353230-��L
315
M3BP 355MLB 6 3GBP353420-��L
355
M3BP 355LKA 6 3GBP353810-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1152 1152 1165 1164 1174 1182 1176 1179 1179 1182 1190 1191 1190 1191 1192 1193 1195 1195 1194 1196 1193 1193 1194 1194 1194
460 V 60 Hz 82.5 82.4 75.0 76.2 85.2 85.0 88.5 88.1 87.5 86.5 87.5 86.6 91.0 91.4 91.0 91.3 91.7 92.0 91.7 91.9 93.0 92.9 93.0 92.8 93.5 93.3 94.1 94.2 94.5 94.3 94.5 94.5 95.0 94.7 95.0 94.9 95.0 94.8 95.8 95.5 95.8 95.8 95.8 95.8 95.8 95.8 95.8 95.8 95.8 95.7
80.1 74.4 82.9 86.0 83.9 84.4 90.6 90.6 91.2 91.0 91.8 91.4 92.1 94.8 93.1 93.5 93.6 93.8 93.7 94.4 95.1 95.2 95.1 95.1 94.9
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.75 1.6 5.2 6.2
2.3 3.3 0.0056
0.73 2.5 5.5 9.09 2.3 3.3 0.0068
0.65 3.4 6.1 12.3 2.9 4.0 0.012
0.67 4.84 6.8 18
2.5 3.9 0.0196
0.58 7.5 7.3 24.2 2.9 4.3 0.0355
0.58 9.9 7.3 32.3 2.9 4.3 0.0416
0.62 10.5 6.0 44.6 2.0 3.1 0.0408
0.77 13.5 6.7 60.7 1.4 3.8 0.089
0.76 19.8 7.2 89.1 1.9 3.6 0.138
0.78 26.1 5.7 122 1.6 3.1 0.212
0.82 30.6 7.5 149 2.6 3.7 0.496
0.81 36.7 8.3 177
3.1 4.2 0.585
0.77 52.6 8.7 241 3.5 4.3 0.724
0.80 61.8 7.4 297 2.7 4.4 1.3
0.83 72 8.4 360 2.9 3.3 1.87
0.84 87 8.6 441 3.0 3.3 2.57
0.84 118 7.7 600 2.0 2.9 4.1
0.84 143 8.2 720 2.2 3.3 4.6
0.83 175 8.3 880 2.4 3.4 4.9
0.82 211 8.3 1055 2.5 3.5 6.3
0.82 257 7.6 1281 2.6 2.8 7.9
0.82 320 7.7 1600 2.8 2.7 9.7
0.81 408 8.8 2000 3.2 3.4 11.3
0.83 495 7.9 2521 2.8 3.6 13.5
0.80 579 8.6 2840 3.2 3.6 15.5
Weight kg
Sound
pressure
Level LPA dB
29
56
33
47
41
52
53
69
75
60
82
60
81
57
146 68
180 67
212
69
272 68
297 68
349 67
431 69
645 75
725 74
930 78
1000 79
1040 78
1200 72
1520 78
1680 78
1820 78
2180 79
2500 76
Output kW
Motor type
Product code
1200 r/min = 6 poles
18.5
M3BP 180MLB 6 3GBP183420-��L
37
M3BP 225SMB 6 3GBP223220-��L
45
M3BP 250SMB 6 3GBP253220-��L
55
M3BP 250SMC 6 3GBP253230-��L
75
4) M3BP 280SMD 6 3GBP283240-��L
160
M3BP 315LKA 6 3GBP313810-��L
180
M3BP 315LKB 6 3GBP313820-��L
200
M3BP 315LKC 6 3GBP313830-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1183 1188 1192 1191 1192 1195 1195 1194
460 V 60 Hz 93.0 93.0 94.1 94.4 94.5 94.5 94.5 94.7 94.8 94.7 95.8 95.6 95.8 95.6 96.1 96.1
91.9 93.8 93.5 94.0 93.8 94.6 94.8 95.5
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.73 34.2 7.4 149 2.5 3.5 0.22
0.80 61.8 8.0 297 3.0 3.3 0.813
0.80 75 8.6 361 3.2 3.6 1.5
0.81 90.1 8.2 441 3.3 3.5 1.49
0.85 116 8.7 601 3.1 3.3 3
0.81 259 8.5 1279 2.5 3.5 7.3
0.82 287 8.7 1438 2.6 3.4 8.3
0.81 322 8.0 1599 2.5 3.1 9.2
Weight kg
Sound
pressure
Level LPA dB
219
69
382 72
465 72
466 72
740 76
1410 79
1520 79
1600 79
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Temperature rise class F 3) Efficiency class IE1 4) Efficiency class IE2
ABB Motors and Generators | 9AKK105944 EN 02-2020
49
Technical data, 400 V 50 Hz
IE4 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE4 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3000 r/min = 2 poles
11
M3BP 160MLA 2 3GBP161410-��M
15
M3BP 160MLB 2 3GBP161420-��M
18.5
M3BP 160MLC 2 3GBP161430-��M
22
M3BP 180MLA 2 3GBP181410-��M
30
M3BP 200MLA 2 3GBP201410-��M
37
M3BP 200MLB 2 3GBP201420-��M
45
M3BP 225SMA 2 3GBP221210-��M
55
M3BP 250SMA 2 3GBP251210-��M
75
M3BP 280SMB 2 3GBP281220-��M
90
M3BP 280SMC 2 3GBP281230-��M
110
M3BP 315SMB 2 3GBP311220-��M
132
M3BP 315SMC 2 3GBP311230-��M
160
M3BP 315MLA 2 3GBP311410-��M
200
M3BP 315MLB 2 3GBP311420-��M
200 1) M3BP 355SMA 2 3GBP351210-��M
250
M3BP 315LKB 2 3GBP311820-��M
250 1) M3BP 355SMB 2 3GBP351220-��M
315 1) M3BP 355SMC 2 3GBP351230-��M
355 1) M3BP 355MLA 2 3GBP351410-��M
400 1) M3BP 355MLB 2 3GBP351420-��M
450 1) M3BP 355MLC 2 3GBP351430-��M
500 1) M3BP 355LKA 2 3GBP351810-��M
560 2) M3BP 400LA 2 3GBP401510-��M
630 2) M3BP 400LB 2 3GBP401520-��M
710 2) M3BP 400LC 2 3GBP401530-��M
800 2)3) M3BP 450LA 2 3GBP451510-��M
900 2)3) M3BP 450LB 2 3GBP451520-��M
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
2953 2955 2943 2960 2957 2955 2971 2976 2980 2981 2982 2986 2983 2983 2985 2982 2983 2984 2981 2982 2983 2982 2988 2987 2987 2990 2990
400 V 50 Hz 92.6 92.9 93.3 93.5 93.7 94.4 94.0 94.3 94.5 94.8 94.8 95.4 95.0 95.2 95.3 95.5 95.6 95.6 95.8 95.6 96.0 96.0 96.2 96.3 96.3 96.5 96.5 96.8 96.5 96.2 96.5 96.8 96.5 96.6 96.5 96.5 96.5 96.7 96.5 96.2 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.2 96.5 96.3 96.5 96.2 96.5 96.2
92.4 93.0 94.5 94.1 94.9 95.4 94.5 95.2 94.9 95.0 95.3 95.9 96.3 96.7 95.4 96.8 96.2 95.9 96.3 95.5 95.7 96.0 95.7 95.6 95.7 95.4 95.5
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.88 19.5 8.3 35.6 3.3 4.1 0.0514
0.88 26.5 9.0 48.5 3.8 4.4 0.0612
0.90 31.9 8.6 60.7 3.3 4.0 0.079
0.88 38.4 8.5 71.5 2.7 3.5 0.126
0.91 50.5 7.3 96.9 2.1 3.0 0.196
0.89 63.7 7.5 121 2.7 3.7 0.217
0.88 77.5 8.0 145 3.4 3.6 0.323
0.88 94.4 8.4 178 3.3 3.6 0.634
0.87 129 7.3 240 2.5 2.9 0.9
0.88 153 8.0 288 3.0 3.1 1.15
0.88 189 6.7 352 1.9 2.6 1.4
0.88 226 7.9 422 2.4 3.0 1.7
0.90 268 7.3 512 2.2 2.7 2.1
0.90 333 6.8 640 1.9 2.6 2.2
0.90 336 7.6 640 2.0 3.1 3
0.91 413 7.9 800 2.5 2.7 2.9
0.90 415 7.6 800 2.2 3.0 3.4
0.89 533 7.8 1008 2.3 2.8 3.6
0.90 595 7.5 1137 2.3 2.6 4.1
0.88 677 7.1 1280 2.3 2.9 4.1
0.90 743 7.9 1440 2.2 2.9 4.3
0.90 827 7.5 1601 2.0 3.9 4.8
0.89 934 7.8 1789 2.5 3.7 7.9
0.89 1049 7.6 2014 2.6 3.7 8.2
0.89 1178 7.2 2270 2.6 3.4 9.3
0.87 1362 7.8 2555 1.3 3.4 12.2
0.87 1534 7.6 2874 1.5 3.1 13.5
Weight kg
Sound
pressure
Level LPA dB
140.6 69
169.8 69
179
67
224 67
289.1 72
309 72
395 74
483 75
665 77
725 77
940 77
1025 77
1190 77
1220 77
1600 83
1540 77
1680 83
1750 83
2000 83
2000 83
2080 83
2320 83
2950 82
2950 82
3050 82
4000 85
4000 85
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class 3
50
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE4 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE4 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1500 r/min = 4 poles
11
M3BP 160MLA 4 3GBP162410-��M
15
M3BP 160MLB 4 3GBP162420-��M
18.5
M3BP 180MLA 4 3GBP182410-��M
22
M3BP 180MLB 4 3GBP182420-��M
30
M3BP 200MLA 4 3GBP202410-��M
37
M3BP 225SMA 4 3GBP222210-��M
45
M3BP 225SMB 4 3GBP222220-��M
55
M3BP 250SMA 4 3GBP252210-��M
75
M3BP 280SMC 4 3GBP282230-��M
90
M3BP 280MLA 4 3GBP282410-��M
110
M3BP 315SMC 4 3GBP312230-��M
132
M3BP 315SMD 4 3GBP312240-��M
160
M3BP 315MLB 4 3GBP312420-��M
200
M3BP 315LKB 4 3GBP312820-��M
200
M3BP 355SMA 4 3GBP352210-��M
250
M3BP 315LKC 4 3GBP312830-��M
250
M3BP 355SMB 4 3GBP352220-��M
315
M3BP 355SMC 4 3GBP352230-��M
355
M3BP 355MLA 4 3GBP352410-��M
400
M3BP 355MLB 4 3GBP352420-��M
450
M3BP 355MLC 4 3GBP352430-��M
500
M3BP 355LKA 4 3GBP352810-��M
630
M3BP 400LB 4 3GBP402520-��M
800
M3BP 450LA 4 3GBP452510-��M
900
M3BP 450LB 4 3GBP452520-��M
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1477 1478 1482 1479 1486 1480 1478 1483 1487 1489 1491 1490 1490 1490 1491 1490 1491 1490 1491 1490 1489 1490 1491 1491 1491
400 V 50 Hz 93.3 93.4 93.9 94.1 94.2 94.2 94.5 95.0 94.9 94.9 95.2 95.7 95.4 96.0 95.7 95.8 96.0 96.4 96.1 96.5 96.3 96.5 96.4 96.6 96.6 96.8 96.7 96.9 96.7 96.8 96.7 96.9 96.7 96.8 96.7 96.8 96.7 96.9 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.7 96.5
92.9 93.2 93.5 94.9 94.2 95.6 96.2 95.4 96.1 96.4 96.1 96.2 96.4 96.8 96.4 96.8 96.5 96.5 96.5 96.3 96.5 96.1 96.2 96.2 96.0
Current
Power
factor IN Cosj A
IS/IN
B-design
0.79 21.6 7.6
0.76 30.6 8.3
0.83 34.2 8.6
0.82 41 6.7
0.76 60.2 8.7
0.84 66.9 7.5
0.85 80.8 7.3
0.83 100 7.8
0.86 130 7.8
0.85 160 8.8
0.85 194 7.8
0.85 234 7.9
0.87 278 7.9
0.87 346 7.6
0.87 345 7.3
0.87 432 7.8
0.87 433 7.8
0.86 554 7.4
0.87 616 7.9
0.85 700 6.8
0.86 779 6.8
0.86 865 6.8
0.86 1091 7.6
0.86 1388 7.0
0.85 1575 7.0
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
71.1 2.7 3.7 0.123 98.4 3.5 3.9 0.127 121 3.0 3.8 0.191 142 2.1 2.7 0.188 194 4.1 4.2 0.369 239 3.1 3.2 0.536 291 2.5 2.9 0.536 354 3.3 3.5 0.933 481 2.8 2.9 1.85 577 3.4 3.2 2.3 704 2.4 3.1 2.9 846 2.6 3.2 3.2 1026 2.7 3.0 3.9 1282 2.5 2.9 5 1282 2.1 2.7 5.9 1601 2.3 3.0 5.5 1601 2.5 2.9 6.9 2017 2.8 2.9 7.2 2274 2.7 2.9 8.4 2563 2.1 2.8 8.4 2886 2.4 2.8 8.4 3204 2.0 3.0 10 4034 2.2 2.9 16 5121 1.3 2.8 23 5761 1.3 2.8 25
Weight kg
Sound
pressure
Level LPA dB
188 62
175
62
226 62
231.6 62
304 63
383 66
402.6 66
467 67
725 72
840 72
1000 68
1065 68
1220 68
1480 74
1610 74
1600 74
1780 74
1820 74
2140 78
2140 78
2140 78
2500 78
3300 78
4050 85
4050 85
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class 3
Output kW
Motor type
1500 r/min = 4 poles 560 3) M3BP 400LA 4 710 3) M3BP 400LC 4 1000 3) M3BP 450LC 4
Product code
3GBP402510-��M 3GBP402530-��M 3GBP452530-��M
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 1491 96.7 96.7 96.3 1491 96.7 96.7 96.2 1491 96.7 96.7 96.1
Current
Power
factor IN Cosj A
IS/IN
F-design
0.85 982 7.4
0.84 1227 7.6
0.86 1724 6.8
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
3586 2.4 2.8 15 4547 2.4 3.0 17 6404 1.3 2.7 30
Weight kg
Sound
pressure
Level LPA dB
3200 78 3300 78 4350 85
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class 3
ABB Motors and Generators | 9AKK105944 EN 02-2020
51
Technical data, 400 V 50 Hz
IE4 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE4 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1000 r/min = 6 poles
7.5
M3BP 160MLA 6 3GBP163410-��M
11
M3BP 160MLB 6 3GBP163420-��M
15
M3BP 180MLA 6 3GBP183410-��M
18.5
M3BP 200MLA 6 3GBP203410-��M
22
M3BP 200MLB 6 3GBP203420-��M
30
M3BP 225SMA 6 3GBP223210-��M
37
M3BP 250SMA 6 3GBP253210-��M
45
M3BP 280SMB 6 3GBP283220-��M
55
M3BP 280SMC 6 3GBP283230-��M
75
M3BP 315SMC 6 3GBP313230-��M
90
M3BP 315SMD 6 3GBP313240-��M
110
M3BP 315MLB 6 3GBP313420-��M
132
M3BP 315LKA 6 3GBP313810-��M
160
M3BP 315LKC 6 3GBP313830-��M
160
M3BP 355SMB 6 3GBP353220-��M
200
M3BP 355SMC 6 3GBP353230-��M
250
M3BP 355MLB 6 3GBP353420-��M
315
M3BP 355LKA 6 3GBP353810-��M
355
M3BP 355LKB 6 3GBP353820-��M
400
M3BP 400LA 6 3GBP403510-��M
450
M3BP 400LB 6 3GBP403520-��M
500
M3BP 400LC 6 3GBP403530-��M
560
M3BP 400LD 6 3GBP403540-��M
630
M3BP 450LA 6 3GBP453510-��M
710
M3BP 450LB 6 3GBP453520-��M
800 3) M3BP 450LC 6 3GBP453530-��M
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 984 91.3 91.0 89.4 980 92.3 92.3 91.7 985 92.9 92.8 91.8 991 93.4 94.1 93.6 986 93.7 94.0 94.0 988 94.2 94.5 94.1 989 94.5 94.9 94.8 992 94.8 95.1 94.6 990 95.1 95.4 95.1 994 95.4 95.6 95.2 994 95.6 95.8 95.4 994 95.8 96.0 95.8 993 96.0 96.2 96.0 994 96.2 96.4 96.3 995 96.2 96.2 95.7 995 96.3 96.5 96.1 995 96.5 96.7 96.6 994 96.6 96.7 96.5 995 96.7 96.7 96.3 993 96.6 96.7 96.4 993 96.6 96.7 96.4 994 96.6 96.5 95.8 993 96.6 96.6 96.1 995 96.6 96.6 95.9 995 96.6 96.7 96.1 995 96.6 96.6 96.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.75 15.7 7.1 72.8 1.8 3.6 0.133
0.76 22.8 7.3 109 1.9 3.4 0.133
0.72 32.6 7.4 147 2.8 3.8 0.254
0.81 35.2 7.8 178 2.3 3.5 0.448
0.81 42.4 6.9 216 2.5 3.1 0.531
0.78 59.2 7.3 290 3.0 3.4 0.813
0.81 69.4 6.8 357 2.1 2.8 1.49
0.85 80.9 6.9 434 2.4 2.6 2.2
0.85 99.4 6.8 506 2.4 2.6 2.85
0.83 138 7.0 721 2.2 2.8 4.9
0.81 170 7.2 864 2.4 2.9 4.9
0.83 202 6.9 1057 2.3 2.7 6.3
0.82 243 6.9 1269 2.4 2.7 7.3
0.82 297 7.4 1537 2.7 2.9 9.2
0.82 294 7.0 1536 2.1 2.7 9.7
0.82 367 7.3 1920 2.3 2.8 11.3
0.83 456 7.1 2399 2.3 2.7 13.5
0.83 576 6.9 3026 2.3 2.6 15.5
0.81 668 7.7 3407 2.7 2.9 16.5
0.82 729 7.4 3846 2.5 2.6 17
0.82 820 7.0 4327 2.4 2.4 18.6
0.83 900 8.0 4803 2.6 3.1 22
0.85 984 7.4 5386 2.4 2.8 24
0.82 1146 7.5 6046 1.4 3.2 31
0.85 1244 7.0 6814 1.3 2.5 37
0.84 1415 7.2 7677 1.3 2.7 41
Weight kg
Sound
pressure
Level LPA dB
186.9 59 189 59 240 59 291 63 306 63 369 63 457 63 680 65 725 65 1000 67 1040 67 1200 68 1410 68 1600 68 1680 73 1820 73 2180 73 2500 76 2600 76 2900 76 2990 76 3300 76 3400 77 4150 81 4500 81 4800 81
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class 3
52
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 460 V 60 Hz
IE4 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE4 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3600 r/min = 2 poles
11
M3BP 160MLA 2 3GBP161410-��M
15
M3BP 160MLB 2 3GBP161420-��M
18.5
M3BP 160MLC 2 3GBP161430-��M
22
M3BP 180MLA 2 3GBP181410-��M
30
M3BP 200MLA 2 3GBP201410-��M
37
M3BP 200MLB 2 3GBP201420-��M
45
M3BP 225SMA 2 3GBP221210-��M
55
M3BP 250SMA 2 3GBP251210-��M
75
M3BP 280SMB 2 3GBP281220-��M
90
M3BP 280SMB 2 3GBP281230-��M
110
M3BP 315SMB 2 3GBP311220-��M
155
M3BP 315SMC 2 3GBP311230-��M
200
M3BP 315MLB 2 3GBP311420-��M
200 1) M3BP 355SMA 2 3GBP351210-��M
250
M3BP 315LKB 2 3GBP311820-��M
250 1) M3BP 355SMB 2 3GBP351220-��M
315 1) M3BP 355SMC 2 3GBP351230-��M
355 1) M3BP 355MLA 2 3GBP351410-��M
400 1) M3BP 355MLB 2 3GBP351420-��M
450 1)3) M3BP 355MLC 2 3GBP351430-��M
500 1) M3BP 355LKA 2 3GBP351810-��M
560 2) M3BP 400LA 2 3GBP401510-��M
630 2)3) M3BP 400LA 2 3GBP401510-��M
710 2)3) M3BP 400LB 2 3GBP401520-��M
780 2)3) M3BP 400LC 2 3GBP401530-��M
800 2)3) M3BP 450LA 2 3GBP451510-��M
900 2)3) M3BP 450LB 2 3GBP451520-��M
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
3558 3559 3555 3564 3562 3560 3575 3579 3582 3582 3598 3583 3584 3586 3583 3585 3586 3583 3582 3585 3584 3588 3588 3587 3587 3591 3591
460 V 60 Hz 92.4 92.4 92.4 92.3 93.0 93.2 93.0 93.0 93.6 93.8 94.1 94.2 94.5 94.1 94.5 94.3 95.0 94.6 95.4 95.0 95.4 94.9 95.8 95.5 96.2 96.2 96.2 95.8 96.2 96.2 96.2 95.8 96.2 95.8 96.2 95.9 96.2 95.6 96.2 95.8 96.2 95.9 96.2 95.8 96.2 95.9 96.2 95.9 96.2 95.9 96.2 95.9 96.2 95.9
91.1 91.1 92.6 92.0 93.4 93.6 92.9 93.2 93.3 93.8 93.5 94.7 95.5 94.8 95.8 94.8 94.8 94.9 94.3 94.8 95.0 94.5 94.7 94.7 94.8 94.7 95.1
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.90 16.6 9.9 29.5 3.1 4.5 0.0514
0.90 22.5 10.8 40.2 3.6 4.8 0.0612
0.89 27.9 9.7 50.4 4.0 4.8 0.079
0.87 33.4 9.5 59.3 3.7 4.4 0.126
0.91 43.9 8.3 80.4 2.3 3.3 0.196
0.89 55.1 8.5 99.2 3.1 4.5 0.217
0.87 67.7 9.2 120 3.7 4.1 0.323
0.89 82.5 9.2 148 3.7 4.0 0.634
0.87 113 8.2 200 2.5 3.2 0.9
0.88 133 9.0 240 3.4 3.4 1.15
0.88 165 7.5 293 1.9 2.9 1.4
0.89 228 7.7 413 2.1 2.8 1.7
0.90 290 7.7 533 2.0 2.9 2.2
0.88 295 8.5 533 2.0 3.4 3
0.91 359 9.0 666 2.6 3.0 2.9
0.90 363 8.5 666 2.3 3.3 3.4
0.89 466 8.7 839 2.3 3.1 3.6
0.90 518 8.5 944 2.3 2.9 4.1
0.88 589 8.3 1066 2.3 3.2 4.1
0.90 650 8.9 1199 2.2 3.2 4.3
0.90 722 9.0 1332 2.4 4.3 4.8
0.89 818 9.0 1490 2.3 3.8 7.9
0.89 914 7.9 1676 2.0 3.5 7.9
0.89 1029 7.9 1890 2.1 3.4 8.2
0.90 1116 8.2 2076 2.5 3.5 9.3
0.87 1188 8.0 2127 1.3 3.5 12.2
0.85 1366 7.8 2393 1.5 3.4 13.5
Weight kg
Sound
pressure
Level LPA dB
141
73
170
73
179
71
224 71
289 76
309 76
395 78
483 79
665 80
725 80
940 80
1025 82
1220 80
1600 86
1540 80
1680 86
1750 86
2000 86
2000 88
2080 88
2320 88
2950 86
2950 86
2950 86
3050 86
4000 90
4000 90
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class 3
ABB Motors and Generators | 9AKK105944 EN 02-2020
53
Technical data, 460 V 60 Hz
IE4 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE4 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1800 r/min = 4 poles
11
M3BP 160MLA 4 3GBP162410-��M
15
M3BP 160MLB 4 3GBP162420-��M
18.5
M3BP 180MLA 4 3GBP182410-��M
22
M3BP 180MLB 4 3GBP182420-��M
30
M3BP 200MLA 4 3GBP202410-��M
37
M3BP 225SMA 4 3GBP222210-��M
45
M3BP 225SMB 4 3GBP222220-��M
55
M3BP 250SMA 4 3GBP252210-��M
75
M3BP 280SMC 4 3GBP282230-��M
90
M3BP 280MLA 4 3GBP282410-��M
110
M3BP 315SMC 4 3GBP312230-��M
132
M3BP 315SMD 4 3GBP312240-��M
160
M3BP 315MLB 4 3GBP312420-��M
200
M3BP 355SMA 4 3GBP352210-��M
250
M3BP 355SMB 4 3GBP352220-��M
315
M3BP 355SMC 4 3GBP352230-��M
355
M3BP 355MLA 4 3GBP352410-��M
400
M3BP 355MLB 4 3GBP352420-��M
450
M3BP 355MLB 4 3GBP352420-��M
450
M3BP 355MLC 4 3GBP352430-��M
500
M3BP 355MLC 4 3GBP352430-��M
500
M3BP 355LKA 4 3GBP352810-��M
560 4) M3BP 400LA 4 3GBP402510-��M
630
M3BP 400LB 4 3GBP402520-��M
710 3) M3BP 400LC 4 3GBP402530-��M
800 4) M3BP 450LA 4 3GBP452510-��M
900
M3BP 450LB 4 3GBP452520-��M
1000 3) M3BP 450LC 4 3GBP452530-��M
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1780 1782 1781 1782 1789 1784 1782 1785 1787 1790 1792 1791 1791 1792 1792 1791 1792 1791 1790 1791 1789 1791 1792 1793 1792 1792 1792 1792
460 V 60 Hz 93.6 93.5 94.1 93.9 94.5 94.7 94.5 95.0 95.0 94.7 95.4 95.5 95.4 95.7 95.8 95.0 96.2 96.1 96.2 96.2 96.2 96.0 96.5 96.3 96.5 96.5 96.5 96.2 96.8 96.6 96.8 96.6 96.8 96.6 96.8 96.7 96.8 96.7 96.8 96.7 96.8 96.8 96.8 96.3 96.2 96.0 96.8 96.6 96.8 96.6 96.7 96.5 96.8 96.3 96.8 96.6
92.5 92.6 93.9 94.8 93.7 95.1 95.5 94.1 95.3 95.4 95.3 95.6 95.9 95.4 96.0 96.1 96.0 96.1 96.3 96.2 96.3 95.2 95.3 95.9 96.0 96.0 96.0 95.8
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.77 19.2 8.6 59
3.0 4.2 0.123
0.75 27 9.5 81.7 3.8 4.6 0.127
0.82 29.9 9.2 100 3.2 4.3 0.191
0.82 35.3 7.7 118 2.3 3.1 0.188
0.74 53.3 9.5 160 4.3 4.9 0.369
0.83 58.6 8.6 198 3.4 3.5 0.536
0.83 71.1 8.4 241 2.8 3.2 0.536
0.81 88.3 7.9 294 3.8 4.0 0.933
0.84 116 8.9 400 3.0 3.2 1.85
0.84 136 9.8 481 3.6 3.5 2.3
0.83 172 8.8 586 2.6 3.4 2.9
0.84 206 9.0 704 2.8 3.6 3.2
0.86 241 9.0 853 2.9 3.3 3.9
0.87 301 8.3 1065 2.2 3.0 5.9
0.86 381 8.8 1332 2.7 3.2 6.9
0.85 479 8.5 1679 3.1 3.2 7.2
0.86 542 9.0 1890 2.9 3.2 8.4
0.85 609 8.5 2132 2.6 3.2 8.4
0.86 677 7.6 2400 2.2 2.8 8.4
0.85 685 8.2 2399 2.5 3.1 8.4
0.85 761 7.4 2669 2.2 2.8 8.4
0.85 763 8.0 2666 2.4 3.4 10
0.84 863 7.8 2985 2.7 3.1 15
0.85 960 8.9 3355 2.2 3.3 16
0.84 1091 7.9 3784 2.5 3.3 17
0.85 1222 6.5 4263 1.3 3.1 23
0.85 1373 7.9 4794 1.3 3.1 25
0.86 1505 7.2 5329 1.4 2.8 30
Weight kg
Sound
pressure
Level LPA dB
188 66
175
66
226 66
232 66
304 67
383 70
403 72
467 71
725 72
840 75
1000 71
1065 71
1220 71
1610 77
1780 77
1820 77
2140 81
2140 82
2140 82
2140 82
2140 82
2500 83
3200 83
3300 83
3300 83
4050 89
4050 89
4350 89
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class 3
54
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 460 V 60 Hz
IE4 cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE4 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1200 r/min = 6 poles
7.5
4) M3BP 160MLA 6 3GBP163410-��M
11
M3BP 160MLB 6 3GBP163420-��M
15
M3BP 180MLA 6 3GBP183410-��M
18.5
M3BP 200MLA 6 3GBP203410-��M
22
M3BP 200MLB 6 3GBP203420-��M
30
M3BP 225SMA 6 3GBP223210-��M
37
M3BP 250SMA 6 3GBP253210-��M
45
4) M3BP 280SMB 6 3GBP283220-��M
55
4) M3BP 280SMC 6 3GBP283230-��M
90
M3BP 315SMD 6 3GBP313240-��M
110
M3BP 315MLB 6 3GBP313420-��M
132
M3BP 315LKA 6 3GBP313810-��M
160
M3BP 315LKC 6 3GBP313830-��M
160
M3BP 355SMB 6 3GBP353220-��M
200
M3BP 355SMC 6 3GBP353230-��M
250
M3BP 355MLB 6 3GBP353420-��M
315
M3BP 355LKA 6 3GBP353810-��M
355
M3BP 355LKB 6 3GBP353820-��M
400
M3BP 400LA 6 3GBP403510-��M
450
M3BP 400LA 6 3GBP403510-��M
500 4) M3BP 400LC 6 3GBP403530-��M
560 4) M3BP 400LC 6 3GBP403530-��M
630 3) M3BP 400LD 6 3GBP403540-��M
710
M3BP 450LA 6 3GBP453510-��M
710
M3BP 450LB 6 3GBP453520-��M
800
M3BP 450LC 6 3GBP453530-��M
900 3) M3BP 450LC 6 3GBP453530-��M
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1186 1184 1186 1192 1189 1190 1191 1193 1190 1195 1194 1194 1195 1195 1196 1195 1195 1195 1194 1193 1195 1194 1193 1195 1196 1195 1195
460 V 60 Hz 91.3 90.6 93.0 93.5 93.0 92.7 94.1 94.1 94.1 93.8 95.0 94.9 95.0 94.8 95.3 95.2 95.3 95.3 95.8 95.6 96.2 96.0 96.2 96.0 96.2 96.0 96.2 96.0 96.2 95.7 96.5 96.5 96.5 96.5 96.5 96.2 96.5 96.4 96.5 96.6 96.4 96.0 96.5 96.3 96.5 96.5 96.5 96.3 96.5 96.2 96.5 96.4 96.6 96.6
88.3 92.8 91.1 93.4 93.4 94.1 94.5 94.3 94.5 94.9 95.4 95.5 95.3 95.3 95.0 95.8 95.9 95.4 95.9 96.2 95.1 95.5 95.9 95.5 95.5 95.7 96.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.73 14.1 7.8 60.4 1.9 4.0 0.133
0.77 19.2 7.1 88.8 1.7 3.5 0.133
0.79 29.1 7.9 122 2.9 4.4 0.254
0.80 31 8.8 148.3 2.7 4.0 0.448
0.80 37.1 8.1 178.6 3.0 3.5 0.531
0.75 52.6 7.7 242.6 1.5 1.8 0.813
0.80 61.3 7.7 297 2.4 3.1 1.49
0.85 70.6 7.9 361 2.6 2.9 2.2
0.85 86.2 7.8 420 2.6 2.9 2.85
0.80 149 8.2 719 2.7 3.2 4.9
0.81 177 7.9 880 2.6 3.0 6.3
0.81 215 7.9 1055 2.7 3.0 7.3
0.81 259 8.4 1279 3.0 3.2 9.2
0.81 260 7.9 1278 2.3 3.0 9.7
0.82 320 8.3 1598 2.5 3.1 11.3
0.82 401 9.2 1997 2.3 3.0 13.5
0.83 500 7.9 2516 2.6 2.9 15.5
0.80 584 8.8 2835 3.0 3.2 16.5
0.81 642 8.1 3199 2.5 2.9 17
0.83 705 7.3 3602 2.2 2.7 17
0.82 793 8.8 3995 2.6 3.7 22
0.84 867 8.0 4479 2.3 3.3 22
0.86 952 7.5 5042 2.3 2.8 24
0.82 1126 7.1 5674 1.4 3.2 31
0.85 1085 8.2 5671 1.4 2.9 37
0.83 1254 8.4 6393 1.4 3.3 41
0.84 1392 7.2 7191 1.2 2.7 41
Weight kg
Sound
pressure
Level LPA dB
187
63
189 63
240 63
291 67
306 67
369 67
457 67
680 68
725 68
1040 70
1200 71
1410 71
1600 71
1680 76
1820 76
2180 76
2500 79
2600 79
2900 79
2900 79
3300 79
3300 79
3400 79
4150 85
4500 85
4800 85
4800 85
1) -3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 2) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045. 3) Temperature rise class F 4) Efficiency class IE1
ABB Motors and Generators | 9AKK105944 EN 02-2020
55
Variant codes
Cast iron motors
Variant codes specify additional options and features to the standard motor. The desired features are listed as three-digit variant codes in the motor order. Note also that there are variants that cannot be used together.
Most of the variant codes apply to IE2, IE3, and IE4 motors. However, confirm the availability of variants for IE3 and IE4 motors with your ABB sales office before making an order.
Frame size
Code/Variants
71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
Administration 529 Customer witnessed visual inspection of complete order line. 530 Two-year extension on standard warranty 531 Sea freight packing 533 Wooden sea freight packing 590 Mounting of customer supplied part other than coupling. 683 Prepared for ABB Ability Smart Sensor 684 ABB Ability Smart sensor mounted
- - - - - - - - - - - - -
Balancing 417 Vibration acc. to Grade B (IEC 60034-14). 423 Balanced without key. 424 Full-key balancing
Bearings and Lubrication
036 Transport lock for bearings.
037 Roller bearing at D-end.
039 Cold-resistant grease
040 Heat-resistant grease
041 Bearings regreasable via grease nipples.
043 SPM compatible nipples for vibration measurement
057 2RS bearings at both ends.
- - - - -
058 Angular contact bearing at D-end, shaft force away from bearing.
059 Angular contact bearing at N-end, shaft force towards bearing.
- - - - - - - - - - -
060 Angular contact bearing at D-end, shaft force towards bearing.
- - - - - - - - - - -
061 Angular contact bearing at N-end, shaft force away from bearing.
- - - - - - - - - - -
107 Pt100 2-wire in bearings.
- - - - - -
128 Double PT100, 2-wire in bearings
- - - - - -
129 Double PT100, 3-wire in bearings
- - - - - -
130 Pt100 3-wire in bearings.
- - - - - -
188 63-series bearing in D-end
194 2Z bearings greased for life at both ends.
- - - - -
420 Bearing mounted PTC thermistors.
- - - - - - - - - - -
433 Outlet grease collector
- - - - - - - - - - -
506 Nipples for vibration measurement : SKF Marlin Quick Connect stud - - - - - - CMSS-2600-3
593 Bearings grease suitable for food and beverage industry.
654 Provision for vibration sensors (M8x1)
795 Lubrication information plate
- - - - - -
796 Grease nipples JIS B 1575 PT 1/8 Type A
797 Stainless steel SPM nipples
798 Stainless steel grease nipples
799 Grease nipples flat type DIN 3404, thread M10x1
800 Grease nipples JIS B 1575 PT 1/8" pin type
- - - - - -
Brakes 517 KFB holding brake 518 SFB-SH holding brake
- - - - - - - - - - - - - - - - - - - - - - - -
Branch standard designs 142 Manilla connection.
- - - - -
= Included as standard = Available as option - = Not applicable
56
9AKK105944 EN 02-2020 | ABB Motors and Generators
Frame size
Code/Variants
71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
172 Smoke venting specification, 300 �C, 1 hour, DOL use, class F300 ac- - - - - - - - - - - - cording to EN 12101-3
173 Smoke venting specification, 200 �C, 2 hours, DOL use, class F200 according to EN 12101-3
- - - - - - - - - - - -
174 Smoke venting specification, 400 �C, 2 hours, DOL use, class F400 according to EN 12101-3
- - - - - - - - - - - -
177 Design for high ambient applications
- - - - - - - - - - -
178 Stainless steel / acid proof bolts.
204 Jacking bolts for foot mounted motors.
- - - - - -
209 Non-standard voltage or frequency, (special winding).
386 Smoke venting specification, 200 �C, 2 hours, VSD use, Class F200 according to EN 12101-3.
- - - - - - - - - - - -
387 Smoke venting specification, 300 �C, 1 hour, VSD use, Class F300 ac- - - - - - - - - - - - cording to EN 12101-3
389 Smoke Venting specification, 400 �C, 2 hours, VSD use, Class F400 according to EN 12101-3
- - - - - - - - - - - -
392 Smoke Venting specification, 250 �C, 2 hours, DOL use, Class T250
- - - - - - - - - - - -
393 Smoke venting specification, 250 �C, 2 hours, VSD use, Class T250
- - - - - - - - - - - -
396 Motor designed for minimum ambient temperature -20 �C to -40 �C, with space heaters (code 450/451 must be added)
397 Motor designed for minimum ambient temperature -40 �C to -55 �C, - - - - - - with space heaters (code 450/451 must be added)
398 Motor designed for minimum ambient temperature -20 �C to -40 �C
399 Motor designed for minimum ambient temperature -40 �C to -55 �C - - - - - -
425 Corrosion protected stator and rotor core.
524 Special run-out tolerances on flange and shaft for close coupled pump applications.
- - - - - - - - - - - - -
625 Design for mining applications.
-
786 Special design shaft upwards (V3, V36, V6) for outdoor mounting.
- - - - - - - - - - - -
877 Design for high ambient applications, motor without fan and fan cover
- - - - - - - - - - -
Cooling system
044 Unidirectional fan for reduced noise level. Rotation clockwise seen from D-end. Available only for 2-pole motors.
- - - - - - - - - - -
045 Unidirectional fan for reduced noise level. Rotation counter clockwise - - - - - - - - - - - seen from D-end. Available only for 2-pole motors.
068 Light alloy metal fan
075 Cooling method IC418 (without fan).
183 Separate motor cooling (fan axial, N-end).
206 Steel fan
-
422 Separate motor cooling (on top) with integrated fan motor
- - - - - - - - - - -
514 Separate motor cooling (fan on top)
- - - - - - - - - - -
791 Stainless steel fan cover
- - - - - - - - -
Coupling 035 Assembly of customer supplied coupling-half.
- - - - - - - - - - -
Documentation 141 Binding 2D main dimension drawing. 370 Motor model drawing in 3D 374 Binding 2D motor detailed drawing 536 Photos of manufactured motors 537 Advanced data sheet 722 Rotor dimension drawing (incl. torosional stiffness) 777 Premium documentation package
Drain holes 065 Plugged existing drain holes. 448 Draining holes with metal plugs.
- - - - - - - - - - -
Earthing Bolt 067 External earthing bolt. 525 External earthing bolts on motor feet
-
Hazardous Environments 456 Ex ec IIC T3 Gc acc. IEC/EN 60079-7 with certificates.
- - - - - - - - - - - - -
Heating elements 450 Heating element, 100-120 V 451 Heating element, 200 - 240 V
= Included as standard = Available as option - = Not applicable
ABB Motors and Generators | 9AKK105944 EN 02-2020
57
Frame size
Code/Variants
71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
Insulation system 014 Winding insulation class H. 405 Special winding insulation for frequency converter supply. 406 Winding insulation for supply > 690 <= 1000 volts
- - - - - - - -
Marine
024 Fulfilling Bureau Veritas (BV) requirements, with certificate.
025 Fulfilling Det Norske Veritas (DNV) requirements, with certificate.
026 Fulfilling Lloyds Register of Shipping (LR) requirements, with certifi- cate.
027 Fulfilling American Bureau of Shipping (ABS) requirements, with certificate.
049 Fulfilling Germanischer Lloyd (GL) requirements, with certificate.
050 Fulfilling Registro Italiano Navale (RINA) requirements, with certificate.
051 Fulfilling Russian Maritime Register of Shipping (RS) requirements, with certificate.
096 Fulfilling Lloyds Register of Shipping (LR) requirements, without certificate (non-essential duty only)
186 Fulfilling Det Norske Veritas (DNV) requirements, without certificate
481 Fulfilling Nippon Kaiji Kyokai (NK) requirements, with certificate.
483 Fulfilling China Classification Societies (CCS) requirements (Beijing), with certificate.
484 Fulfilling Korea Register of Shipping (KR) requirements, with certifi- cate.
491 Fulfilling Nippon Kaiji Kyokai (NK) requirements, without certificate.
492 Fulfilling Registro Italiano Navale (RINA) requirements, without certificate.
493 Fulfilling China Classification Societies (CCS) requirements (Beijing), without certificate.
494 Fulfilling Korea Register of Shipping (KR) requirements, without certificate.
496 Fulfilling Bureau Veritas (BV) requirements, without certificate(non- essential duty only)
497 Fulfilling Russian Maritime Register of Shipping (RS) requirements, - without certificate.
675 Fulfilling American Bureau of Shipping (ABS) requirements, without certificate (non-essential duty only)
676 Fulfilling Germanischer Lloyd (GL) requirements, without certificate (non-essential duty only)
Mounting arrangements
008 IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3).
- - - - - - - - - -
009 IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3).
047 IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5).
- - - - - - - - - -
064 NEMA D-flange
- - - - - - - - - - - - - - -
066 Modified for specified mounting position differing from IM B3 (1001), IM B5 (3001), B14 (3601), IM B35 (2001), IM B34 (2101)
305 Additional lifting lugs.
- - - - - -
320 IM2001 foot/flat bottom flange mounted, from IM1001 (B35 flat bot- - - - - - - - - tom flange from B3)
Noise reduction 055 Noise reduction cover for foot mounted motor
- - - - - - - - - - -
Painting 105 Paint thickness report. 114 Special paint color, standard grade 115 Painting system C4M acc. to ISO 12944-2: 1998. 168 Primer paint only. 303 Painted insulation layer on inside of the terminal boxes. 710 Thermally sprayed zink metallizing with acrylic top coat 711 Painting system C5-M very high, acc. to ISO 12944-5:2007 712 Painting system C5-M according to Petrobras specification. 713 Painting system according Total Egina specification. 754 Painting system C5M acc. to ISO 12944-2:1998 755 Norsok M-501 revision 6, Coating system no. 1
- - - - - - - - - - - -
Protection
= Included as standard = Available as option - = Not applicable
58
9AKK105944 EN 02-2020 | ABB Motors and Generators
Frame size
Code/Variants
71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
005 Protective roof 072 Radial seal at D-end. Not possible for 2-pole , 280 and 315 frames 073 Sealed against oil at D-end. 158 Degree of protection IP65. 211 Weather protected, IP xx W 250 Degree of protection IP66 401 Protective roof, horizontal motor. 403 Degree of protection IP56. 404 Degree of protection IP56, without fan and fan cover. 434 Degree of protection IP56, open deck. 520 Motor protection cover made of glass fiber. Vertical motor, shaft
down. 783 Labyrinth sealing at D-end. 784 Gamma-seal at D-end.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - -
Rating & instruction plates
002 Restamping voltage, frequency and output, continuous duty.
004 Additional text on std rating plate (max 12 digits on free text line).
095 Restamping output (maintained voltage, frequency), intermittent duty.
098 Stainless rating plate.
- -
126 Tag plate
135 Mounting of additional identification plate, stainless.
138 Mounting of additional identification plate, aluminium.
- - - - - - - - - -
139 Additional identification plate delivered loose.
159 Additional plate with text "Made in ...."
160 Additional rating plate affixed.
161 Additional rating plate delivered loose.
163 Frequency converter rating plate. Rating data according to quotation.
181 Rating plate with ABB standard loadability values for VSD operation. Other auxiliaries for VSD operation to be selected as necessary.
332 Baldor Catalogue #
- -
333 Not for use in the USA
- -
360 Cargotec rating plate
- - - - - -
528 Rating plate sticker
- - - - -
818 Restamping as generator
- - - - - -
Shaft & rotor 069 Two shaft extensions according to catalog drawings. 070 Special shaft extension at D-End, standard shaft material 131 Motor delivered with half key (key not exceeding shaft diameter) 155 Cylindrical shaft extension, D-end, without key-way. 164 Shaft extension with closed keyway 165 Shaft extension with open keyway 410 Shaft material stainless steel 591 Special shaft extension according to customer specification. 600 Special shaft extension at N-end, standard shaft material. 630 Shaft material certificate 3.1/3.2 according to EN10204:2004
- - - - - - - - - - - - - - - -
Standards and Regulations
010 Fulfilling CSA Safety Certificate.
- - - - - -
208 Fulfilling Underwriters Laboratories (UL), listed requirements
252 Shell DEP 33.66.05.31-GEN. February 2012, with standard winding >55 - - - - - - - - - - - - kW.
331 IE1 motor not for sale for use in EU
421 VIK design (Verband der Industriellen Energie- und Kraftwirtschaft e.V.).
-
540 China energy label
- -
543 Australian MEPS
- - -
546 SABS rating plate
-
548 Certificate of conformity according TR-CU 004/2011 for customs union RU, KZ, BY, AM, KG.
822 WIMES 3.03i6 Compliant Design for DOL operation
- - - - - - -
823 WIMES 3.03i6 Compliant Design for VSD operation
Stator winding temperature sensors
= Included as standard = Available as option - = Not applicable
ABB Motors and Generators | 9AKK105944 EN 02-2020
59
Frame size
Code/Variants
71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
120 KTY 84-130 (1 per phase) in stator winding.
- - - - - -
121 Bimetal detectors, break type (NCC), (3 in series), 130 �C, in stator winding
122 Bimetal detectors, break type (NCC), (3 in series), 150 �C, in stator winding
123 Bimetal detectors, break type (NCC), (3 in series), 170 �C, in stator winding
124 Bimetal detectors, break type (NCC), (3 in series), 140 �C, in stator winding
- - - - - -
125 Bimetal detectors, break type (NCC), (2x3 in series), 150 �C, in stator - - - - - - winding
127 Bimetal detectors, break type (NCC), (3 in series, 130 �C & 3 in series, 150 �C), in stator winding
435 PTC - thermistors (3 in series), 130 �C, in stator winding
437 PTC - thermistors (3 in series), 170 �C, in stator winding
438 PTC - thermistors (3 in series), 190 �C, in stator winding
- - - - - - - - - - -
439 PTC - thermistors (2x3 in series), 150 �C, in stator winding
441 PTC - thermistors (3 in series, 130 �C & 3 in series, 150 �C), in stator winding
442 PTC - thermistors (3 in series, 150 �C & 3 in series, 170 �C), in stator winding
445 Pt100 2-wire in stator winding, 1 per phase
446 Pt100 2-wire in stator winding, 2 per phase
- - - - - -
502 Pt100 3-wire in stator winding, 1 per phase
- - - - - -
503 Pt100 3-wire in stator winding, 2 per phase
- - - - - -
511 PTC thermistors (2 x 3 in series), 130 �C, in stator winding
- - - - - -
515 Pt100 3-wire in stator winding, 3 per phase
- - - - - - - - - - -
Terminal box
015 Motor supplied in D connection.
- - - - -
017 Motor supplied in Y connection.
- - - - -
019 Larger than standard terminal box.
- - - - - -
020 Detached terminal box.
- - - - - - - - - - -
021 Terminal box LHS (seen from D-end).
-
022 Cable entry LHS (seen from D-end).
157 Terminal box degree of protection IP65.
- - - - - - -
180 Terminal box RHS (seen from D-end).
-
230 Standard metal cable gland.
- -
277 Cable sealing end unit, size small for C-opening
- - - - - - - - - - -- - - -
278 Cable sealing end unit, size medium for D-opening
- - - - - - - - - - - -
279 Cable sealing end unit, size large for D-opening
- - - - - - - - - - - -
292 Adapter C-C
- - - - - - - - - - -- - - -
293 Adapter D-D
- - - - - - - - - - - - - -
294 Adapter E-D
- - - - - - - - - - - -
295 Adapter E-2D
- - - - - - - - - - - -
296 Adapter E-3D
- - - - - - - - - - - - - -
351 Terminal block turned according to cable entry
- - - - - - - - - - - -
375 Standard plastic cable gland
- - - - -
376 Two standard plastic cable glands
- - - - -
380 Separate terminal box for temperature detectors, std. material
- - - - - -
400 4 x 90 degr turnable terminal box.
- -
413 Extended cable connection, no terminal box.
- - - - - -
418 Separate terminal box for auxiliaries, standard material.
444 Adapter E-2E
-------------- -
447 Top mounted separate terminal box for monitoring equipment.
- - - - - - - - - - -
466 Terminal box at N-end.
- - - - - -
467 Lower than standard terminal box and rubber extended cable. Cable - - - - - - - - - - length 2 m
468 Cable entry from D-end.
- -
469 Cable entry from N-end.
-
526 Existing cable entries plugged
- -
553 Terminal box degree of protection IP66.
-
554 Cast iron flange for cable glands drilled and tapped according to order.
- - - - - -
557 Nickel plated cable glands mounted according to order.
-
= Included as standard = Available as option - = Not applicable
60
9AKK105944 EN 02-2020 | ABB Motors and Generators
Frame size
Code/Variants
71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
565 Adapter for terminal box on the side (RHS)
- - - - - - - - - -
566 Adapter for terminal box on the side (LHS)
- - - - - - - - - -
567 Separate terminal box material: cast Iron
- - - - - -
568 Separate terminal box for heating elements, std. material
- - - - - -
569 Separate terminal box for brakes
- - - - - -
624 Prepared for inch cable glands according to BSPP standard.
727 Stainless steel flange for cable glands drilled and tapped according to order.
- - - - - -
730 Prepared for NPT cable glands.
731 Two standard metal cable glands.
740 Prepared for PG cable glands.
- - - - - - - - - - -
742 Protective cover for accessory terminal block in main terminal box.
- - - - - - - - - - -
743 Non-drilled cast iron flange for cable glands
- - - - - -
744 Stainless steel non-drilled flange for cable glands.
- - - - - -
745 Painted steel flange equipped with nickel plated brass cable glands - - - - - -
746 Stainless steel cable flange equipped with standard nickel plated brass cable glands
- - - - - -
Testing
140 Test confirmation.
- - - - - - - - - - -
145 Type test report from a catalogue motor, 400V 50Hz.
146 Type test with report for one motor from specific delivery batch.
148 Routine test report.
149 Test according to separate test specification.
- - - - - - - - - - -
150 Customer witnessed testing. Specify test procedure with other codes.
222 Torque/speed test, type test and multi-point load test with report for one motor from specific delivery batch.
560 Shaft voltage test.
561 Overspeed test,for one motor from specific delivery batch
562 Overvoltage test.
760 Vibration level test
761 Vibration spectrum test for one motor from specific delivery batch. - - - - - -
762 Noise level test for one motor from specific delivery batch.
763 Noise spectrum test for one motor from specific delivery batch.
- - - - - -
764 Test for one motor from specific delivery batch with ABB frequency - - - - - - converter available at ABB test field. ABB standard test procedure.
Variable speed drives
429 Separate motor cooling (fan top, N-end) and 1024 pulse tacho (Leine - - - - - - - - - - - & Linde 861) mounted.
470 Prepared for hollow shaft pulse tacho (L&L equivalent).
- - - - - -
472 1024 pulse tacho (L&L 861007455-1024).
- - - -
473 2048 pulse tacho (L&L 861007455-2048).
- - - -
474 Separate motor cooling (axial fan, N-end) and prepared for hollow shaft tacho (L&L equivalent)
- - - - - -
476 Separate motor cooling (axial fan, N-end) and 1024 pulse tacho (L&L - - - - - - 861007455-1024)
477 Separate motor cooling (axial fan, N-end) and 2048 pulse tacho (L&L - - - - - - 861007455-2048)
478 Separate motor cooling (fan on top, N-end) and prepared for hollow - - - - - - - - - - - shaft tacho (L&L equivalent)
479 Mounting of other type of pulse tacho with shaft extension, tacho not included.
- - - - - - - -
486 Separate motor cooling (fan top, N-end) and prepared for DC-tacho. - - - - - - - - - - -
510 Separate motor cooling (fan top, N-end) and 2048 pulse tacho (Leine - - - - - - - - - - - & Linde 861) mounted.
570 Prepared for hollow shaft pulse tacho (L&L 503).
- - - - - - - - - - -
572 1024 pulse tacho (L&L 503).
- - - - - - - - - - -
573 2048 pulse tacho (L&L 503).
- - - - - - - - - - -
582 1024 pulse tacho, GHK912-GBR-1024, BEI IDEACOD
- - - - - - - - - - -
583 2048 pulse tacho, GHK912-GBR-2048, BEI IDEACOD
- - - - - - - - - - -
588 Shaft grounding device
- - - - - - - -
658 Special tacho mounted, price category 1
- - - - - -
659 Special tacho mounted, price category 2
- - - - - -
660 Special tacho mounted, price category 3
- - - - - -
680 2048 pulse tacho, Ex d, tD, L&L 841910001
- - - - - - - - - - -
= Included as standard = Available as option - = Not applicable
ABB Motors and Generators | 9AKK105944 EN 02-2020
61
Code/Variants 701 Insulated bearing at N-end. 702 Insulated bearings at both ends 704 EMC cable entry. Y/D starting 117 Terminals for Y/D start at both speeds (two speed windings). 118 Terminals for Y/D start at high speed (two speed windings). 119 Terminals for Y/D start at low speed (two speed windings).
= Included as standard = Available as option - = Not applicable
Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
- - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
62
9AKK105944 EN 02-2020 | ABB Motors and Generators
Mechanical design
Motor frame and drain holes
Motor frame
01 As standard,
motor sizes 71 - 450 are
The motor frame, end shields and main terminal
delivered with drain holes and closable plugs.
box are made of cast iron. Feet are integrated with the frame, except for sizes 160-250 with side
mounted terminal box, which have detachable feet.
Motors can be supplied for foot mounting, flange
mounting, and combinations of these.
Drain holes
Motors are provided with drain holes fitted with
closable plugs as standard. The plugs are made of
plastic material and are delivered in open position.
When mounting arrangement differs from foot
mounted IM B3, mention variant code 066 when
ordering to ensure the drain plug is mounted in the
lowest position.
open closed
open
__ 01
ABB Motors and Generators | 9AKK105944 EN 02-2020
63
Lifting lugs The motors are provided as standard with lifting lugs according to the table below. For improved lifting possibilities can variant code 305 be added, please refer to the variant code section for information about availability.
Frame size 71, 80 90-132 160-200 225-250 280, 315
355
400
450
Type of lugs No lugs, weight of motors is less than 25kg Detachable eye bolt Integrated in casting / detachable eye bolt Integrated in casting / detachable eye bolt Detachable eye bolt
Detachable eye bolt
Detachable eye bolt
Detachable eye bolt
Foot mounted motors -
Flange mounted motors -
2 pcs on top of motor diagonally placed, size M8
2 pcs on top of motor diagonally placed, size M8
2 pcs on top of motor diagonally placed, integrated in frame casting
Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end. 2 pcs eye bolts size M12 delivered with each motor
2 pcs on top of motor diagonally placed, integrated in frame casting
Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end. 2 pcs eye bolts size M16 delivered with each motor
1 pcs close to terminal box on top, size M24
Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end, one location on top close to terminal box. 2 pcs eye bolts size M24 delivered with each motor
1 pcs close to terminal box on top, size M30
Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end, one location on top close to terminal box. 2 pcs eye bolts size M30 delivered with each motor
1 pcs close to terminal box on top, size M36
Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end, one location on top close to terminal box. 2 pcs eye bolts size M36 delivered with each motor
Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end, one location on top close to terminal box. 3 pcs eye bolts size M42 delivered with each motor
Locations for eye bolts: 4 pcs at N-end and 4 pcs at D-end, one location on top close to terminal box. 2 pcs eye bolts size M42 delivered with each motor
64
9AKK105944 EN 02-2020 | ABB Motors and Generators
Mechanical design
Heating elements
Heating elements are installed into windings to keep them free of corrosion in humid conditions. The required power of heating elements is shown in the table. You can order heating elements with variant code 450 or 451.
Motor 71 size
Power 8 (W)
80 90
8
25
100 112 132 160 180 25 25 25 25 50
Motor 200 225 250 280 315 355 400 450 size Power 50 50 50 60 2x60 2x60 2x60 2x100 (W)
ABB Motors and Generators | 9AKK105944 EN 02-2020
65
Mechanical design
Bearings
Process performance motors are normally fitted with single-row deep-groove ball bearings, as shown in the table below. If the bearing at the D-end is replaced with a roller bearing (NU- or NJ-), higher radial forces can be handled. Roller bearings are suitable for belt-drive applications and can be ordered with variant code 037. When high axial forces are involved, angular-contact ball bearings should be used. When ordering a motor with an angular-contact ball bearing, specify also the method of mounting and the direction and magnitude of axial force. The variant codes for ordering angular-contact ball bearings are 058 and 059.
Standard and alternative designs
Standard design
Motor size 71 80 90 100 112 132 160 180 200 225 250 280
315
355
400
450
1) On request
Number of poles 2 - 8 2 - 8 2 - 8 2 - 8 2 - 8 2 - 8 2 - 12 2 - 12 2 - 12 2 - 12 2 - 12 2 4 - 12 2 4 - 12 2 4 - 12 2 4 - 12 2 4 - 12
Deep groove ball bearings
D-end 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6206-2Z/C3 6206-2Z/C3 6208-2Z/C3 6309/C3 6310/C3 6312/C3 6313/C3 6315/C3 6316/C3 6316/C3 6316/C3 6319/C3 6316M/C3 6322/C3 6317M/C3 6324/C3 6317M/C3 6326M/C3
N-end 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6205-2Z/C3 6208-2Z/C3 6209/C3 6209/C3 6210/C3 6212/C3 6213/C3 6316/C3 6316/C3 6316/C3 6316/C3 6316M/C3 6316/C3 6317M/C3 6319/C3 6317M/C3 6322/C3
Alternative designs
Roller bearings (037)
Ang. contact ball bearings (058, 059)
D-end NU 203 ECP/C3 NU 204 ECP/C3 NU 205 ECP/C3 NU 206 ECP/C3 NU 206 ECP/C3 NU 208 ECP/C3 NU 309 ECP/C3 NU 310 ECP/C3 NU 312 ECP/C3 NU 313 ECP/C3 NU 315 ECP/C3
1)
NU 316 ECP/C3
1)
NU 319 ECP/C3
1)
NU 322 ECP/C3
1)
NU 324 ECP/C3
1)
NU 326 ECP/C3
D-end 7203 B 7204 B 7205 B 7206 B 7206 B 7208 B 7309 B 7310 B 7312 B 7313 B 7315 B 7316 B 7316 B 7316 B 7319 B 7316 B 7322 B 7317 B 7324 B 7317 B 7326 B
N-end 7202 B 7203 B 7204 B 7205 B 7205 B 7208 B 7209 B 7209 B 7210 B 7212 B 7213 B 7616 B 7316 B 7316 B 7316 B 7316 B 7316 B 7317 B 7319 B 7317 B 7322 B
66
9AKK105944 EN 02-2020 | ABB Motors and Generators
01 Motor sizes 71 - 132. 02 Motor sizes 160 - 250. 03 Motor sizes 280 - 450 Labyrinth seal. 04 V-ring. 05 Radial seal.
Axially-locked bearings All motors are equipped as standard with an axially locked bearing at the D-end. Transport locking Motors with roller bearings or an angular-contact ball bearing are fitted with a transport lock before dispatch to prevent damage to bearings during transport. A warning sign is attached to motors larger than 250 when transport locking is used. Locking may also be fitted in other cases if severe transport conditions are expected. Bearing seals These tables present the standard and alternative sizes and types of bearing seals per motor size.
Bearing seals
Standard design
Alternative design
NumMotor ber of size poles
71
2 - 12
80 2 - 12
90 2 - 12
100 2 - 12
112 2 - 12
132 2 - 12
160 2 - 12
180 2 - 12
200 2 - 12
225 2 - 12
250 2 - 12
Axial seal
D-end Gamma seal Gamma seal Gamma seal Gamma seal Gamma seal VA40 RB45 RB50 RB60 RB65 RB75
N-end Gamma seal Gamma seal Gamma seal Gamma seal Gamma seal VA40 RB45 RB45 RB50 RB60 RB65
Radial seal at D-end (DIN 3760)
Variant code 072 17x28x7 20x40x7 25x42x7 30x47x7 30x47x7 40x62x7 45x62x8 50x68x8 60x80x8 65x85x10 75x95x10
__
__
__
01
02
03
__
__
04
05
Bearing seals
Motor size 280 280
Number of poles 2 4 - 12 4 - 12
315 315 SM, ML
2 4 - 12 4 - 12
315 LK
4 - 12 4 - 12
355
2
355
4 - 12
400
2
400
4 - 12
450
2
450
4 - 12
Table is valid for IE2 motors Axial seal: RB45...75 = Gamma-ring VA16...65 = V-ring, type A VS80...95 = V-ring, type S
Standard design
D-end Labyrinth seal VS80
N-end, IE2-IE3 motors VS80 VS80
N-end, IE4 motors Labyrinth seal Labyrinth seal Labyrinth seal
Labyrinth seal VS95
VS80 VS80
Labyrinth seal Labyrinth seal Labyrinth seal
Labyrinth seal VS80
Labyrinth seal Labyrinth seal
Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal
VS80 VS80 Labyrinth seal VS95 Labyrinth seal Labyrinth seal
Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal
Alternative design
D-end Labyrinth seal Radial seal 80x110x10 Labyrinth seal Radial seal 95x125x10 -
-
N-end Labyrinth seal Labyrinth seal Radial seal 80x110x10 Labyrinth seal Labyrinth seal Radial seal 80x110x10 Labyrinth seal Radial seal 80x110x10 Labyrinth seal Labyrinth seal Labyrinth seal -
ABB Motors and Generators | 9AKK105944 EN 02-2020
67
Bearing life and lubrication Bearing life The nominal life L10h of a bearing is defined according to ISO 281 as the number of operating hours achieved or exceeded by 90 % of identical bearings in a large test series under specified conditions. 50 % of bearings achieve at least five times this lifetime. The calculated bearing life L10h for power transmission by means of coupling is for horizontally mounted motors in sizes 280 to 315 200,000 hours. Lubrication On delivery, motors in frame size 160 and above are prelubricated with high-quality grease. Before first start-up, see instructions for relubricaton and recommended grease in the Manual for low voltage motors delivered together with the motor, or see the lubrication plate on the motor. Motors with bearings greased for life Motors in frame sizes 71 - 132 are equipped with bearings greased for life, while this is available as an option for frame sizes 160 - 250. Bearings are lubricated with high-quality, high-temperature grease. Bearing types are stated on the rating plate. The approximate lifetime of bearings in four-pole motors is about 40 000 duty hours. Lifetime is subject to the load conditions of the application run by the motor.
Lubrication intervals ABB follows the L1 principle in defining lubrication intervals. This means that 99 % of motors will make the interval time. The lubrication intervals can also be calculated according to the L10 principle, which usually gives twice as long interval times. L10 values are available from ABB at request. Motors with relubrication nipples In frame sizes 280 - 450, the bearing system allows the use of a valve disc to ease lubrication. Motors are lubricated while running. The grease outlet opening has closing valves at both ends. These should be opened before greasing and closed 1 - 2 hours after regreasing. This ensures that the construction is tight and bearings remain dust- and dirt-free. A grease-collection method can be used optionally. The following tables show lubrication intervals according to the L1 principle for various nominal speeds in 25 �C ambient temperature. These values apply to horizontally mounted motors (B3) with 80 �C bearing temperature and high-quality grease containing lithium-complex soap and mineral or PAO-oil.
68
9AKK105944 EN 02-2020 | ABB Motors and Generators
Lubrication intervals in duty hours for ball bearings
Frame size
Amount Amount
of
of
grease grease
g/bear- g/N- Output
ing
end
kW
Speed 3600 r/min
Ball bearings
Lubrication intervals in duty hours
160
13
13
18.5
160
13
13
> 18.5
180
15
15
22
180
15
15
> 22
200
20
15
37
200
20
15
> 37
225
23
20
45
250
23
20
> 45
250
30
23
55
250
30
23
> 55
280
35
35
all
280
40
40
315
35
35
all
315
55
40
355
35
35
all
355
70
40
400
40
40
all
400
85
55
450
40
40
all
450
95
70
9000 7500 7000 6000 5500 3000 4000 1500 2500 1000 1900 1900 1900 1500 1500 -
Speed 3000 r/min
12 000 10 000 9000 8500 8000 5500 6500 2500 4000 1500 3200 3200 3200 2700 2700 -
Speed
Output 1800
kW
r/min
15 > 15 22 > 22 30 > 30 45 > 45 55 > 55
all
all
all
all
all
18 000 15 000 15 500 14 000 14 500 10 000 13 000 5000 9000 3500 7800 5900 4000 3200 2500
Speed 1500 r/min
21 500 18 000 18 500 17 000 17 500 12 000 16 500 6000 11 500 4500 9600 7600 5600
4700 3900
Speed
Output 1000
kW
r/min
Speed
Output 500-900
kW
r/min
11 > 11 15 > 15 22 > 22 30 > 30 37 > 37
all
all
all
all
all
24 000 all
22 500 all
24 000 all
21 000 all
23 000 all
16 000 all
22 000 all
8000 all
15 000 all
6000 all
-
13 900 all
-
11 800 all
-
9600 all
-
-
8600 all
-
7700 all
24 000 24 000 24 000 24 000 24 000 20 000 24 000 10 000 18 000 7000 15 000 12 900 10 700 9700 8700
Lubrication intervals in duty hours for roller bearings
Frame size
Amount Amount
of
of
grease grease
g/bear- g/N- Output
ing
end
kW
Speed 3600 r/min
Roller bearings
Lubrication intervals in duty hours
160
13
13
18.5
160
13
13
> 18.5
180
15
15
22
180
15
15
> 22
200
20
15
37
200
20
15
> 37
225
23
20
45
225
23
20
> 45
250
30
23
55
250
30
23
> 55
280
35
35
all
280
40
40
315
35
35
all
315
55
40
355
35
35
all
355
70
40
400
40
40
all
400
85
55
450
40
40
all
450
95
70
4500 3500 3500 3000 2750 1500 2000 750 1000 500 900 900 900 -
Speed 3000 r/min
6000 5000 4500 4000 4000 2500 3000 1250 2000 750 1600 1600 1600 1300 1300 -
Speed
Output 1800
kW
r/min
15 > 15 22 > 22 30 > 30 45 > 45 55 > 55
all
all
all
all
all
9000 7500 7500 7000 7000 5000 6500 2500 4500 1500 4000 2900 2000 1600 1300
Speed 1500 r/min
10 500 9000 9000 8500 8500 6000 8000 3000 5500 2000 5300 3800 2800 2400 2000
Speed
Output 1000
kW
r/min
11 > 11 15 > 15 22 > 22 30 > 30 37 > 37
all
all
all
all
all
12 000 11 000 12 000 10500 11 500 8000 11 000 4000 7500 3000 7000 5900 4800 4300 3800
Speed
Output 500-900
kW
r/min
all
12 000
all
12 000
all
12 000
all
12 000
all
12 000
all
10 000
all
12 000
all
5000
all
9000
all
3500
-
all
8500
-
all
6500
-
all
5400
-
all
4800
-
all
4400
ABB Motors and Generators | 9AKK105944 EN 02-2020
69
Mechanical design
Radial forces
Permissible loading on the shaft The following table shows permissible radial forces on the shaft in Newtons, assuming zero axial force, a 25 �C ambient temperature, and normal conditions. The values are given for a calculated bearing life of 20 000 and 40 000 hours per motor size. These calculated values further assume mounting position IM B3 (foot-mounted), with force directed sideways. In some cases, the strength of the shaft affects permissible forces. Permissible loads of simultaneous radial and axial forces can be supplied on request. If the radial force is applied between points X0 and Xmax, the permissible force FR can be calculated with the following formula:
X FR = FX0 - E (FX0 - F ) Xmax
Where: E:
length of the shaft extension in the standard version
FR
X
F Xmax
F X0
Permissible radial forces
Motor size Poles
71
2
4
6
8
80
2
4
6
8
90
2
4
6
8
100
2
4
6
8
112
2
4
6
8
132
2
4
6
8
Length of shaft extension E (mm) 30 30 30 30 40 40 40 40 50 50 50 50 60 60 60 60 60 60 60 60 80 80 80 80
Basic design with deep groove ball bearings Roller bearings
Mounting arrangement IM B3
Mounting arrangement IM B3
20,000 h
40,000 h
20,000 h
40,000 h
FX0(N) 540 700 780 860 710 940 1060 1185 820 1035 1185 1300 1130 1425 1635 1820 1170 1475 1690 1860 1840 2320 2660 2925
FXmax(N) 460 605 665 730 600 810 895 1020 690 870 995 1095 925 1165 1335 1520 980 1235 1310 1310 1500 1890 2165 2380
FX0(N) 420 555 620 685 385 725 840 940 650 820 940 1035 900 1135 1295 1445 925 1170 1340 1475 1460 1840 2110 2320
FXmax(N) 360 480 530 580 350 625 710 810 545 690 790 870 735 925 1060 1205 775 980 1120 1235 1190 1500 1715 1890
FX0(N) 1285 1615 1640 1640 1910 2335 2335 2335 2205 2715 3065 3340 2905 3575 4040 4460 3000 3695 4170 4550 4255 5240 5915 6450
FXmax(N) 650 650 650 600 865 865 865 865 1330 1330 1330 1330 1900 1900 1900 1900 1970 1970 1970 1970 3465 4265 3680 3680
FX0(N) 1040 1310 1450 1580 1555 1945 2160 2335 1790 2205 2490 2715 2360 2905 3280 3620 2435 3000 3390 3695 3455 4255 4805 5240
FXmax(N) 650 650 650 600 865 865 865 865 1330 1330 1330 1330 1900 1900 1900 1900 1970 1970 1970 1970 2815 3465 3680 3680
70
9AKK105944 EN 02-2020 | ABB Motors and Generators
Permissible radial forces
Motor size Poles 160 MLA 2
4 6 8 160 MLB 2 4 6 8 160 MLC 2 4 6 8 160 MLD 2 4 160 MLE 2 180 MLA 2 4 6 8 180 MLB 2 4 6 180 MLC 4 200 MLA 2 4 6 8 200 MLB 2 4 6 200 MLC 2 4 6 200 MLD 2 225 SMA 2 4 6 8 225 SMB 2 4 6 8 225 SMC 2 4 225 SMD 2 4 250 SMA 2 4 6 8 250 SMB 2 4 6 250 SMC 2 4 6
Length of shaft extension E (mm) 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 140 140 140 110 140 140 140 110 140 110 140 140 140 140 140 140 140 140 140 140 140
Ball bearings
20,000 h
FX0(N) 3540 4000 4170 4600 3540 4085 4100 4200 3400 3700 3600 4170 3585 3400 3185 4100 4270 4700 4785 4170 4185 4370 3700 5600 6285 6800 6800 5670 5700 6400 5000 5400 5800 4985 6400 7300 7600 8500 6100 7085 7100 8000 5600 6400 5500 5800 7700 8700 9400 9600 7100 7800 8900 6800 7400 8200
FXmax(N) 2740 3100 3200 3585 2740 3300 3355 3270 2600 3000 2900 3370 2900 2755 2570 3385 3485 3800 3900 3400 3400 3570 3055 4685 5200 5700 5700 4700 4700 5370 4185 4500 4885 4170 5400 5900 6200 6900 5185 5700 5700 6485 4700 5200 4640 4700 6285 7000 7600 7800 5800 6300 7200 5500 6000 6600
40,000 h
FX0(N) 2955 3325 3440 3855 2955 3370 3400 3455 2855 3070 2870 3370 3000 2755 2640 3455 3525 3855 3870 3470 3440 3525 3010 4700 5240 5700 5600 4700 4700 5300 4185 4425 4740 4170 5355 6155 6370 7100 5155 5885 5840 6600 4685 5300 4600 4725 6500 7300 7800 7900 6000 6470 7355 5670 6055 6670
FXmax(N) 2285 2570 2655 2985 2270 2725 2755 2670 2200 2485 2325 2725 2440 2240 2140 2825 2885 3155 3170 2825 2810 2885 2470 3925 4370 4770 4685 3925 3925 4425 3500 3685 3955 3485 4500 4970 5140 5725 4340 4755 4700 5340 3940 4285 3880 3800 5285 5900 6355 6400 4885 5240 5955 4600 4900 5400
Roller bearings
20,000 h
FX0(N) 7100 8000 8600 9300 7085 8300 8600 9000 6800 7800 8000 9000 7100 7600 6785 8125 8600 9400 9800 7900 8500 9000 7900 10900 12500 13600 14100 11000 12000 13200 10400 11600 12500 10400 13300 15400 16400 17900 13000 15100 16000 17300 12600 14500 12420 13500 17100 19800 21600 22700 16700 18900 21200 16300 18100 20300
FXmax(N) 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 5500 5500 5500 5500 5500 5500 5500 5500 9100 9550 9550 9550 9200 9550 9550 8700 9550 9550 8700 10700 10250 10250 10250 10700 10250 10250 10250 10600 10250 10460 10250 10900 13800 13800 13800 10900 13800 13800 10900 13800 13800
40,000 h
FX0(N) 6140 6870 7270 7955 6070 7055 7300 7570 5885 6640 6700 7585 6140 6370 5770 7025 7300 7900 8255 6770 7200 7600 6655 9470 10700 11670 12000 9500 10185 11200 8900 9800 10600 8900 11500 13200 14000 15300 11200 12900 13500 14700 10770 12385 10640 11400 14900 17000 18400 19300 14400 16200 18000 14000 15400 17200
FXmax(N) 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 4300 5500 5500 5500 5500 5500 5500 5500 5440 7900 8900 9550 9550 7900 8500 9385 7455 8200 8800 7400 9700 10250 10250 10250 9455 10250 10250 10250 9070 10000 8960 9270 10900 13785 13800 13800 10900 13100 13800 10900 12485 13800
ABB Motors and Generators | 9AKK105944 EN 02-2020
71
Permissible radial forces
Motor size Poles
280 SM_ 2
4
6
8
280 ML_ 2
4
6
8
315 SM_ 2
4
6
8
315 ML_ 2
4
6
8
315 LK_
2
4
6
8
355 SM_ 2
4
6
8
355 ML_ 2
4
6
8
355 LK_ 2
4
6
8
400 L_
2
4
6
8
400 LK_ 2
4
6
8
450 L_
2
4
6
8
Length of shaft extension E (mm) 140 140 140 140 140 140 140 140 140 170 170 170 140 170 170 170 140 170 170 170 140 210 210 210 140 210 210 210 140 210 210 210 170 210 210 210 170 210 210 210 170 210 210 210
Ball bearings
20,000 h
FX0(N) 7300 9200 10600 11700 7400 9200 10500 11600 7300 11400 13000 14400 7400 11500 13200 14500 7400 11500 13200 14600 7350 15200 17500 19300 7350 15300 17600 19400 7350 15200 17500 19400 7650 15600 17800 19700 7650 15600 17800 19700 7400 17000 19000 21300
FXmax(N) 6000 7800 8900 9200 6200 7900 9000 9500 6000 9400 9600 9600 6400 9700 11100 12200 6550 10000 11400 12600 6450 12600 14000 14000 6550 12900 13600 13600 6650 13000 13000 13000 6850 13550 15450 16000 6850 11500 11500 11500 6700 15200 17000 19000
40,000 h
FX0(N) 5800 7300 8400 9200 5800 7300 8300 9200 5800 9000 10300 11400 5850 9100 10400 11500 5800 9100 10450 11550 5750 12000 13800 15250 5750 12000 13900 15300 5650 11850 13700 15200 4400 12150 13850 15350 4400 12150 13850 15350 3500 13000 14000 16500
FXmax(N) 4900 6200 7000 7800 5000 6200 7100 7900 4950 7450 8500 9400 5050 7650 8800 9700 5150 7850 9050 10000 5050 9950 11400 12600 5100 10100 11600 12900 5100 10200 11900 13000 3900 10550 12000 13350 3900 10550 11500 11500 3300 11600 13000 14600
Roller bearings
20,000 h
FX0(N) 20400 25100 28300 30900 20600 25000 28300 30800 20300 32500 37000 40300 20600 32700 36900 40200 20800 33100 37300 40800 20600 45500 51400 56000 20800 45900 51500 56000 21000 46000 52000 56500 23900 52500 60000 65700 23900 52500 60000 65700 24000 62000 70000 76000
FXmax(N) 6000 9200 9200 9200 6200 9500 9400 9500 6000 9600 9600 9600 5850 13600 13600 13600 5550 13350 13350 13350 7200 14000 14000 14000 6750 13600 13600 13600 6550 13000 13000 13000 9050 16000 16000 16000 9050 11500 11500 11500 7500 25000 24000 23000
40,000 h
FX0(N) 16500 20300 23000 25100 16700 20300 22900 25000 16500 26600 30000 32700 16700 26500 29900 32600 16800 26800 30300 33100 16700 36900 41700 45500 16800 37200 42100 45900 17000 37300 42000 46000 19350 43300 48800 53200 19350 43300 48800 53200 19000 50000 56000 62000
FXmax(N) 6000 9200 9200 9200 6200 9500 9400 9500 6000 9600 9600 9600 5850 13600 13600 13600 5550 13350 13350 13350 7200 14000 14000 14000 6750 13600 13600 13600 6550 13000 13000 13000 9050 16000 16000 16000 9050 11500 11500 11500 7500 25000 24000 23000
72
9AKK105944 EN 02-2020 | ABB Motors and Generators
Mechanical design
Axial forces
01 Mounting arrangement IM B3.
02 Mounting arrangement IM V1.
The following tables present permissible axial forces on the shaft in Newtons, assuming zero radial force, a 25 �C ambient temperature, and normal conditions. The values are given for a calculated bearing life of 20,000 and 40,000 hours per motor size. At 60 Hz, the values must be reduced by 10 percent, and for two-speed motors, the higher speed determines permissible axial force. Permissible loads of simultaneous radial and axial forces can be supplied on request. For axial force FAD, it is assumed that the D-bearing is locked with a locking ring.
FAZ FAD
FAD FAZ
__
__
01
02
Permissible axial forces
Motor size Poles
71
2
4
6
8
80
2
4
6
8
90
2
4
6
8
100
2
4
6
8
Length of shaft extension E (mm) 30 30 30 30 40 40 40 40 50 50 50 50 60 60 60 60
Mounting arrangement IM B3
Deep groove ball bearings
20,000 h
40,000 h
FAD(N) 615 760 870 960 880 1075 1215 1330 780 985 1140 1265 925 1480 1690 1865
FAZ(N) 285 430 540 630 300 495 635 750 500 705 860 985 570 860 1070 1245
FAD(N) 505 615 695 765 735 880 985 1070 620 775 890 985 735 1190 1350 1480
FAZ(N) 175 285 365 435 155 300 405 490 340 495 610 705 350 570 730 860
Mounting arrangement IM V1
Deep groove ball bearings
20,000 h
40,000 h
FAD(N) 630 790 890 985 915 1130 1270 1400 840 1070 1225 1355 1285 1600 1815 1995
FAZ(N) 275 410 525 615 280 455 600 705 455 650 800 925 510 780 995 1160
FAD(N) 520 645 720 785 770 935 1040 1140 680 860 975 1075 1060 1305 1470 1610
FAZ(N) 165 265 355 415 135 260 370 450 300 440 555 645 290 490 650 775
ABB Motors and Generators | 9AKK105944 EN 02-2020
73
Permissible axial forces
Motor size Poles
112
2
4
6
8
132
2
4
6
8
160 MLA 2
4
6
8
160 MLB 2
4
6
8
160 MLC 2
4
6
8
160 MLD 2
4
160 MLE 2
180 MLA 2
4
6
8
180 MLB 2
4
6
180 MLC 4
200 MLA 2
4
6
8
200 MLB 2
4
6
200 MLC 2
4
6
200 MLD 2
Length of shaft extension E (mm) 60 60 60 60 80 80 80 80 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110
Mounting arrangement IM B3
Deep groove ball bearings
20,000 h
40,000 h
FAD(N) 1155 1445 1655 1830 1765 2210 2535 2800 2850 3450 3690 4155 2850 3435 3600 3750 2775 3150 3135 3675 2865 2900 2500 3300 3600 4140 4220 3340 3580 3800 3220 4460 5000 5000 5000 4440 4720 5000 3940 4480 4980 3940
FAZ(N) 595 885 1095 1270 965 1410 1735 2000 2850 3450 3690 4155 2850 3435 3600 3750 2775 3150 3135 3675 2865 2900 2500 3300 3600 4140 4220 3340 3580 3800 3220 4460 5260 5480 5880 4440 4720 5480 3940 4480 4980 3940
FAD(N) 935 1155 1315 1445 1420 1755 2000 2205 2325 2775 2970 3315 2325 2760 2880 2970 2280 2535 2490 2910 2330 2320 2025 2700 2920 3320 3360 2725 2900 3040 2560 3640 4260 4720 4700 3620 3840 4420 3180 3620 3980 3200
FAZ(N) 375 595 755 885 620 955 1200 1405 2325 2775 2970 3315 2325 2760 2880 2970 2280 2535 2490 2910 2330 2320 2025 2700 2920 3320 3360 2725 2900 3040 2560 3640 4260 4720 4700 3620 3840 4420 3180 3620 3980 3200
Mounting arrangement IM V1
Deep groove ball bearings
20,000 h
40,000 h
FAD(N) 1290 1595 1810 1985 1925 2420 2770 3055 3100 3820 4100 4440 3120 3880 4120 4140 3080 3620 3680 4240 3220 3420 2900 3660 4160 4800 4960 3760 4220 4500 3880 5000 5000 5000 5000 5000 5000 5000 4600 5000 5000 4660
FAZ(N) 505 785 995 1170 855 1270 1580 1835 2578 3150 3410 3845 2570 3085 3240 3450 2500 2770 2700 3260 2540 2470 2150 2940 3150 3675 3740 2960 3095 3285 2660 3965 4680 5265 5195 3905 4060 4800 3385 3775 4165 3370
FAD(N) 1070 1300 1465 1600 1580 1965 2235 2455 2570 3120 3325 3640 2580 3180 3360 3340 2560 2985 3005 3445 2665 2820 2420 3060 3460 3940 4040 3125 3500 3700 3220 4200 5000 5000 5000 4220 4700 5000 3880 4520 5000 3925
FAZ(N) 280 495 650 780 510 815 1045 1235 2048 2450 2635 3045 2030 2385 2480 2650 1980 2135 2025 2465 1985 1870 1670 2340 2450 2815 2820 2320 2375 2485 2000 3125 3640 4065 3955 3085 3120 3660 2665 2875 3105 2635
74
9AKK105944 EN 02-2020 | ABB Motors and Generators
Permissible axial forces
Motor size Poles
225 SMA 2
4
6
8
225 SMB 2
4
6
8
225 SMC 2
4
225 SMD 2
4
250 SMA 2
4
6
8
250 SMB 2
4
6
250 SMC 2
4
6
280 SM_ 2
4
6
8
280 ML_ 2
4
6
8
315 SM_ 2
4
6
8
315 ML_ 2
4
6
8
315 LK_
2
4
6
8
Length of shaft extension E (mm) 110 140 140 140 110 140 140 140 110 140 110 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 170 170 170 140 170 170 170 140 170 170 170
Mounting arrangement IM B3
Deep groove ball bearings
20,000 h
40,000 h
FAD(N) 4980 5000 5000 5000 4860 5000 5000 5000 4380 5000 4320 4800 6000 6000 6000 6000 5620 6000 6000 5260 5960 6000 6200 8000 7250 10300 6100 7800 8950 10000 6180 9400 10900 12000 6050 9250 10650 11500 6000 9100 10500 11750
FAZ(N) 4980 6080 6520 7420 4860 5880 6020 6940 4380 5240 4320 4800 6080 7140 7880 8200 5620 6320 7480 5260 5960 6860 4250 6000 9250 8300 4100 5800 6950 8000 4200 7400 8900 10000 4050 7250 8650 9900 3950 7150 8500 9750
FAD(N) 4060 4920 5000 5000 3960 4780 4840 5000 3540 4260 3480 3820 4920 5820 6000 6000 4540 5100 6000 4220 4760 5520 4900 6250 7150 7950 4800 6000 6900 7700 4850 7250 8350 9200 4750 7100 8100 8900 4650 7000 7950 8900
FAZ(N) 4060 4920 5260 5960 3960 4780 4840 5560 3540 4260 3480 3820 4920 5820 6380 6600 4540 5100 6040 4220 4760 5520 2900 4250 5150 5950 2800 4000 4900 5700 2850 5250 6350 7000 2750 5100 6100 6800 2650 5000 5950 6900
Mounting arrangement IM V1
Deep groove ball bearings
20,000 h
40,000 h
FAD(N) 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 7550 9600 11150 12200 8150 10450 12350 13450 7950 11750 13600 15350 8650 12500 14900 15400 9100 13100 15700 16900
FAZ(N) 4375 5445 5735 6535 4245 5175 5155 6055 3670 4445 3590 3895 5345 6300 6950 7125 4830 5325 6370 4395 4900 5575 3150 4550 5500 7000 2750 4050 4750 5800 2600 5500 6300 7900 2300 5050 5800 6300 1350 3850 4100 6300
FAD(N) 4780 5000 5000 5000 4780 5000 5000 5000 4440 5000 4400 5000 5840 6000 6000 6000 5640 6000 6000 5400 6000 6000 6200 7800 9000 9850 6800 8650 10250 11050 6600 9550 11050 12450 7300 10300 12350 13600 7750 10900 13100 14100
FAZ(N) 3455 4225 4395 5095 3345 3995 3915 4635 2900 3425 2790 2935 4225 4920 5350 5385 3810 4085 4830 3415 3700 4135 1800 2750 3350 4700 1400 2250 2600 3450 1300 3300 3750 5000
1)
2900 3250 3400
1)
1700 1550 3450
ABB Motors and Generators | 9AKK105944 EN 02-2020
75
Permissible axial forces
Motor size Poles
355 SM_ 2
4
6
8
355 ML_ 2
4
6
8
355 LK_ 2
4
6
8
400 L, LK_ 2
4
6
8
450 L_
2
4
6
8
1) On request.
Length of shaft extension E (mm) 140 210 210 210 140 210 210 210 140 210 210 210 170 210 210 210 170 210 210 210
Mounting arrangement IM B3
Deep groove ball bearings
20,000 h
40,000 h
FAD(N) 3050 8600 10550 12200 2900 8360 10100 12000 2650 8200 9900 11450 2150 7100 8850 10450 1800 7600 9000 10800
FAZ(N) 6850 12400 14350 16000 6700 12150 13900 15800 6450 12000 13700 15250 7150 13100 14850 16450 6800 13500 15000 16800
FAD(N) 1750 5900 7300 8550 1600 5650 6900 7300 1350 5450 6700 7800
1)
4300 5500 6750
1)
4500 5600 7000
FAZ(N) 5550 9700 11100 12350 5400 9450 10700 11000 5150 9250 10500 11600 5800 10300 11500 12750 5500 10500 11500 12900
Mounting arrangement IM V1
Deep groove ball bearings
20,000 h
40,000 h
FAD(N) 6350 13250 15650 17350 7100 14600 18050 21100 8250 15650 19100 21200 8650 16050 18450 20100 11500 20000 26000 27800
FAZ(N) 4250 8600 9580 12500 3700 7950 8600 11650 2650 6600 7050 8700 2150 6400 6750 8350
1)
4400 3700 5500
FAD(N) 4950 10450 12350 13600 5750 11850 14700 17000 6900 12850 15800 17500 7220 13150 15100 16450 10000 17700 22200 23700
FAZ(N) 2900 5850 6270 8900 2350 5150 5300 7600 1300 3800 3750 5000
1)
3400 3400 4700
1)
1200
1)
1350
76
9AKK105944 EN 02-2020 | ABB Motors and Generators
Terminal box
Standard terminal box
Degree of protection and mounting options The degree of protection for the standard terminal box is IP 55. By default, terminal boxes are mounted on top of the motor at D-end. In motor sizes 71 132, the terminal box is integrated in motor frame. On request, the terminal box can also be mounted on the left or right side regardless of motor size (see Mounting options). Turnability In frame sizes 71 to 132 the terminal box is integrated into the frame and can therefore not be turned. Please use the variant code 400 if there is a need to have 4*90� turnability. The standard terminal boxes for motor sizes 160 to 355 can be turned 4*90�. On frame sizes 400-450 the terminal box can not be turned without turning the terminal board. In these frame sizes you need to specify the cable entry direction when ordering, by using the variant codes 022, 468 or 469. Cable entries The terminal box is provided with tapped holes for cable glands. No cable glands are included as standard, the entry holes are closed with blanking plugs made of plastic. Very large motors have an angle adapter between the terminal box and the cable gland. Please refer to the table on the next page for further information about the amount and size of threaded holes, plugs and cable sealing units provided as standard. Different types of cable glands are available as option. Please refer to the terminal box alternatives section for more details.
Cable type and terminations If no cable type is specified in the order, it will be a PVC-insulated non-armored cable, and its termination parts are determined as shown in the following table. Terminations are suitable for copper and aluminum cables. Cables are connected to terminals by cable lugs, which are not included in the delivery. Ordering To ensure the delivery of desired terminations for the motor, state the cable type, quantity, size, and outer diameter when ordering. Non-standard designs of terminal boxes, such as non-standard size or higher degree of protection, are available as options. See section Variant codes for all options available.
ABB Motors and Generators | 9AKK105944 EN 02-2020
77
Standard delivery Standard delivery if no other information is provided. For other network voltages than voltage code D (see description on page 18) and/or side-mounted motors, please contact your ABB sales office.
Motor size
Pole number
Size of gland
plate open-
Terminal box ing on termi- 45� angle
type
nal box
adapter
IE2, IE3, IE4 motors
71
2-8
80
2-8
90
2-8
100-132
2-8
160-180
2-8
200-250
2-8
280
2-8
315SM_, ML_
2-8
315LKA, LKB
2-4
315LKC
2-4
315LK_
6-8
355SMA - SMC
2-4
355SMA, SMB
6-8
355SMC
6
355SMC
8
355MLA
2-4
355MLB, LK_
2-4
355ML_, LK_
6-8
400
2-6
400LA, LB
8
400LC
8
450 LA
2
450 LA
4
450 LB, LC
2-4
450 LA
6
450 LB, LC
6
450
8
integr.
-
integr.
-
integr.
-
integr.
-
63
B
160
C
210
C
370
D
370
D
750
E
370
D
750
E
370
D
750
E
370
D
750
E
750
E
750
E
750
E
750
E
750
E
1200
E
1200
E
1200
E
750
E
1200
E
750
E
E-2D E-2D E-2D E-2D E-2D E-2D E-2D E-2D E-2D E-2D
Amount
and size of
threaded
Max. con-
plugged
nectable core
holes, or
cross-sec- Number and
cable sealing tion mm2/ size of termi-
end unit
phase
nal bolts
2xM16x1.5 2xM25x1.5 2xM25x1.5 2x M32x1.5 2xM40x1.5 2xM63x1.5 2xM63x1.5 2xM63x1.5 2xM63x1.5 2xM75x1.5 2xM63x1.5 2xM75x1.5 2xM63x1.5 2xM75x1.5 2xM63x1.5 2xM75x1.5 4xM75x1.5 2xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5 4xM75x1.5
1x2.5 1x4 1x6 1x10 1x35 1x70 2x150 2x240 2x240 4x240 2x240 4x240 2x240 4x240 2x240 4x240 4x240 4x240 4x240 4x240 4x240 6x240 6x240 6x240 4x240 6x240 4x240
6 x M4 6 x M4 6 x M5 6 x M5 6 x M6 6 x M10 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12 6 x M12
Auxiliary cable entries
160 - 450
2-8
2x M20x1.5
Motor size 71-112 132 160-250 280-400 450
Earthing on frame M4 M5 clamp M10 M10
Earthing in main terminal box M4 M5 M6 2xM10 4xM12
78
9AKK105944 EN 02-2020 | ABB Motors and Generators
Terminal box
Terminal box dimensions
01 Terminal box type 63 and 160.
For motor sizes 71 to 132 the terminal box is integrated in motor frame and the dimensions for
H 1
terminal boxes can be found in the motor dimen-
02 Terminal box types 210
and 370.
sion drawings in ABB Library.
A1
03 Terminal box type 750
+ adapter.
To match the correct terminal box with motor
04 Terminal box type 1200 + adapter.
sizes 160 - 450, find the motor type and correspondent terminal box type on the previous page. The
B 1
box types and heir dimensions are presented on
this page.
__
B1
H1
04
B 1
H 1
B 1
H 1
__ 01
A1
__ 02
A1
__ 03
A 1
Terminal box types acc.
to current capacity
A1 B1
63
247 247
160
300 310
210
416 306
370
451 347
750 with E-D adapter
686 413
750 without E-D adapter 523 413
1200 with E-2D adapter 1000 578
1200 without E-2D adapter
697 578
1200 with E-2E adapter 1195 578
1200 with E-3D adapter 1250 578
Gland plate H1 opening 109 B 154 C 177 C 200 D 219 D 219 E 285 2xD 285 E
285 2xE 285 3xD
Dimensions for terminal box inlets Corresponds to motor sizes 160 and above
d
e
c
f
g
Flange opening B C *) C **) D E
c
e
f
g
d
mm mm mm mm thread type
31
120 30
120 M6
71
194 62
193 M6
67 193 62 193 M8
100 300 80 292 M10
115 370 100 360 M12
Note! The C flange is different depending on frame size *) for frame sizes 200-225 **) for frame size 280
ABB Motors and Generators | 9AKK105944 EN 02-2020
79
Terminal box
Cable glands
The motors are delivered as standard with plugged cable entries or cable sealing units as described in the previous section. There is available a broad selection of different type of cable glands, which are suitable for different types of cable and outer diameter ranges.
Cable
gland(s)
EMC Cable Cable
nickel plated gland(s)
gland(s)
Size of thread- brass, variant nickelplated plastic, vari-
ed opening for code 230 or brass, variant antcode 375
cable gland 731
code 704
or 376
Metric (std) M16 x 1.5 M20 x 1.5 M25 x 1.5 M32 x 1.5 M40 x 1.5 M50 x 1.5 M63 x 1.5 *) M75 x 1.5
Cable outer diameter, mm
4-12 4-12 10-18 14-24 22-32 26-35 35-45 46-62
Cable outer diameter, mm
Cable outer diameter, mm
4-8 4-12 10-18 14-24
4-12 4-12 10-18 14-24
22-32 26-35 35-45 46-62
22-32 26-35 35-45 not available
Gland plates with threaded openings for cable glands of nonstandard size If the standard size of threaded openings for cable glands is not suitable then nonstandard size openings are also available, either by fitting the reducers to make the openings smaller or by increasing the amount or size of holes. The maximum possible size and amount for each gland plate size is listed below. Threaded openings of non-standard size can be ordered by using variant codes 554 and 727.
Gland plate size B C D E
Maximum amount and size of threaded holes 2 x M40 2 x M63 2 x M90 or 3 x M75 2 x M90 or 4 x M75
Threaded openings for cable glands with NPT thread (variant code 730) The standard delivery for the motors are provided with openings for cable glands with metric threads as listed in the section describing the standard terminal box. If NPT threads will be needed, the variant code 730 is to be ordered. If nothing else is stated on the order, the sizes in tables below will be delivered.
Motor frame size 80-112 132 160-180 200-250 280 315-450
Main cable entries NPT plug
1 x �"
-
2 x �"
1 x �"
2 x 1 �"
1 x 1 �"
2 x 1 �"
1 x 1 �"
2 x 2"
1 x 2"
2 x 3"
1 x 3"
Motor frame size 80-112 132 160-450
Cable entries for auxiliaries 2 x �" 1 x �" 2 x �"
NPT plug 2 x �" 1 x �" 2 x �"
80
9AKK105944 EN 02-2020 | ABB Motors and Generators
Terminal box
Terminal boxes and boards
01 Integrated terminal box for motor sizes 71 - 132. Tapped holes for cable entries.
02 Terminal board for motor sizes 71 - 80.
03 Terminal board for motor sizes 90 - 112, IE2, and 90 - 100, IE3.
04 Terminal board for motor sizes 132, IE2, and motor sizes 112 - 132, IE3.
05 Terminal box for motor sizes 160 - 250. Connection flanges with tapped cable entries.
06 Terminal board for motor sizes 160 - 250.
The pictures below show standard terminal boxes and the corresponding terminal boards for various motor sizes. Motor sizes 71 - 132
__ 01
Motor sizes 160 - 250
__ 05
__
__
02
06
__ 03
__ 04
ABB Motors and Generators | 9AKK105944 EN 02-2020
81
07 Terminal box for motor sizes 280 - 315, except LKC. Connection flange with tapped cable entries.
08 Terminal board for motor sizes 280 - 315, except LKC.
09 Terminal box for motor sizes 315-355, except for 355MLB, LK_2-4 where picture 11 applies. Connection flange with tapped cable entries.
10 Terminal board for motor sizes 355-400 and 315 LKC.
11 Terminal box for motor sizes 450, with adapter and cable sealing end unit.
12 Terminal board for motor sizes 450.
Motor sizes 280 - 315
__ 07
__ 08
__ 09
__ 10
Motor size 450
__ 11
__ 12
82
9AKK105944 EN 02-2020 | ABB Motors and Generators
Terminal box
Terminal box alternatives
01 Main terminal box. 02 Adapters, Flange with glands; cable sealing end units.
__ 01 Optional adapters There is a broad selection of cable termination accessories available to allow termination of one or several cables. The most common ones are explained below. How to order? �� Check first that the teminal box itself allows
mounting of the desired cable and cores (refer to motor type and terminal box type cross reference on previous page) �� If very large cables are used it might be necessary to use a larger terminal box than standard. Select the right cable gland(s) or cable sealing end unit(s) that match outer diamater of the cable(s) �� Select appropriate adapter or flange �� Note that turning the terminal box to a nonstandard position might limit the use of some adapters.
__ 02 Main terminal box and maximum single core cross-section You can select one size larger than standard terminal box if a larger single cross-section is needed. The standard sizes of the main terminal box are listed in the following table. The terminal box is named according to its current-carrying capacity, from 120 to 1200. Check also the capacity of the cable entry to make sure that the cables fit. A larger terminal box can be ordered with variant code 019.
Standard terminal box 120 210 370 750 1200
Large terminal box 210 370 750 1200 -
Size of opening, large box B C D E -
Max single cross-section mm2 /phase 1 x 70 2 x 240 2 x 300 4 x 500 -
Ordering example
Motor Cables
200 kW, 4 pole, 400 V 50 Hz 2 pieces, outer diameter 58 mm, single core cross section 185 mm2, clamping device needed, cables coming from below
Needed one terminal box for anticondensation heaters and another for temperature detectors, material must be cast iron.
Motor
M3BP 315 MLA 4-pole, B3
Adapter
D-D - variant code 293
Cable sealing end unit Variant code 278
Clamping
Variant code 231
Auxiliaries
Variant codes 380, 567, 568
ABB Motors and Generators | 9AKK105944 EN 02-2020
83
Optional adapters To allow easy termination of cables entering the terminal box from above or below, an angle adapter is recommended. These are available for motor sizes 280 and above and can also be used to allow the mounting of several cable sealing end units or gland plates. For exact suitability on a certain motor size, refer to the `terminal box opening' column in section Standard terminal box.
Adapter
Variant code
292
Suited for motor sizes 280
Opening to terminal box Flange or opening for end unit Material Notes
C C Steel
293 315, 355
D D Steel
294
315 LKC IE2, 355 SM_ 2-4 poles, 400 - 450
E
295
315 LKC IE2, 355 SM_ 2-4 poles, 400 - 450
E
296
315 LKC IE2, 355 SM_ 2-4 poles, 400 - 450
E
444
315 LKC IE2, 355 SM_ 2-4 poles, 400 - 450
E
D
2 x D
3 x D
2 x E
Cast iron
Steel
Steel
Included as standard Only possible on delivery for frame type 1200 terminal sizes 400-450 and box. 355MLB, LK_ 2-4.
Steel
Only possible on type 1200 terminal box.
Cable sealing end units As an alternative to flanges and cable glands, cable sealing end units can be used. These allow more space for spreading the cores for easy termination. Cable sealing end units have rubber-sealed entries for one of two main cables. In addition, there are two plugged M20 holes for auxiliary cables.
End unit
Small
Medium
Large
Variant code Suited for motor sizes
Opening to terminal box Cable outer diameter Cable entry for auxiliary cable
Additional optional variants
277 280
C 1 - 2 cables, 48 - 60 mm 2 x M20 plugged holes EMC cable gland (704); Standard gland with clamping device (231)
278
315, 355, except 315 LKC IE2, 355 SM_ 2-4 poles
D
1 - 2 cables, 48 - 60 mm
2 x M20 plugged holes
EMC cable gland (704); Standard gland with clamping device (231)
279
315, 355, except 315 LKC IE2, 355 SM_ 2-4 poles
D
1 - 2 cables, 60 - 80 mm
2 x M20 plugged holes
EMC cable gland (704); Standard gland with clamping device (231)
84
9AKK105944 EN 02-2020 | ABB Motors and Generators
Auxiliary terminal box You can equip motors from frame size 160 upward with one or several auxiliary terminal boxes for connection of auxiliaries like heaters or temperature detectors. The standard auxiliary terminal box material for motor sizes 280 - 450 is aluminum and for 160 - 250 cast iron. For 280 - 450, cast iron as box material is also available as an option. Connection terminals are of spring-loaded type for quick and easy connection. These are suitable for up to 2.5 mm2 wires. Auxiliary terminal boxes for 280 - 450 are equipped with an earthing terminal. The first auxiliary terminal box is located on the right-hand side at D-end as standard. The standard cable entry size is M20 for the aluminum box and M16 for the cast iron box, and the number of entries depends on the terminal box type and the number of selected auxiliaries.
Related variant codes 380 418 567 568 569
Separate terminal box for temperature detectors,standard material Separate terminal box for auxiliaries, standard material Separate terminal box material: cast iron Separate terminal box for heating elements, standard material Separate terminal box for brake
Small auxiliary aluminum terminal box Large auxiliary aluminum terminal box for motor Auxiliary cast iron terminal box
for motor sizes 280 - 450
sizes 280 - 450.
Frame size for motor sizes 160 - 250
(variant codes 418, 568, 380, 569)
The size of terminal box ordered with these codes (variant code 418):
The size of terminal box ordered with depends on the number of accessories ordered. 111 x 162 mm, max. 18 strips. No earth-
these codes depends on the number 80 x 250 mm, max 30 strips. Earthing size M4
ing.
of accessories ordered.
80 x 125 mm, max 12 strips. Earthing
size M4
Frame size for motor sizes 280 - 450 (variant code 567): 208 x 180 mm, max 30 strips. Earthing size M6
ABB Motors and Generators | 9AKK105944 EN 02-2020
85
Dimension drawings
Process performance IE2 cast iron motors
L
HD
EC B B'
Foot-mounted motor IM 1001, IM B3
H
K A
DS
PN
LS
Flange-mounted motor IM 3001, IM B5 DS
D
F
GA
M S
45�
Sizes 80 to 200
S
M
LS
45� Sizes 225 to 450
Protective roof, variant code 005
IM1001, IMB3 and IM3001, IMB5
IM1001, IMB3
IM B5 (IM3001)
D Motor size 2
71
14
80
19
90SL_
24
90L_
24
100L_
28
100ML_
28
100LK_
28
112
28
132
38
160 1)
42
160 2)
42
180
48
200
55
225
55
250
60
280SM_
75
280ML_
65
315 SA
65
315 SM_
65
315 ML_
65
315 LK_
65
355 SM_
70
355 ML_
70
355 LK_
70
400 L_
80
400 LK_
80
450
80
GA 4-8 2
F 4-8 2
14 16 16 5
19 21.5 21.5 6
24 27 27 8
24 27 27 8
28 31 31 8
28 31 31 8
28 31 31 8
28 31 31 8
38 41 41 10
42 45 45 12
42 45 45 12
48 51.5 51.5 14
55 59 59 16
60 59 64 16
65 64 69 18
75 79.5 79.5 20
75 69 79.5 18
80 69 85 18
80 69 85 18
90 69 95 18
90 69 95 18
100 74.5 106 20
100 74.5 106 20
100 74.5 106 20
110 85 126 22
100 85 106 22
120 85 127 22
E
L max
A
B
B1 C
HD K
MN
P
S
4-8 2
4-8 2
4-8
max
5
30 30 295 294 112 90 -
45 178 7
130 110 160 10
6
40 40 363 363 125 100 -
50 194 10 165 130 200 12
8
50 50 356 356 140 100 125 56 218 10 165 130 200 12
8
50 50 390 390 140 100 125 56 218 10 165 130 200 12
8
60 60 381 381 160 140 -
63 247 12 215 180 250 15
8
60 60 403 403 160 140 -
63 247 12 215 180 250 15
8
60 60 435 435 160 140 -
63 247 12 215 180 250 15
8
60 60 403 403 190 140 -
70 259 12 215 180 250 15
10 80 80 532 532 216 140 178 89 300 12 265 230 300 15
12 110 110 584 584 254 210 254 108 421 14.5 300 250 350 19
12 110 110 681 681 254 210 254 108 421 14.5 300 250 350 19
14 110 110 726 726 279 241 279 121 461 14.5 300 250 350 19
16 110 110 821 821 318 267 305 133 528 18.5 350 300 400 19
18 110 140 849 879 356 286 311 149 573 18.5 400 350 450 19
18 140 140 884 884 406 311 349 168 626 24 500 450 550 19
20 140 140 1053 1054 457 368 419 190 733 24 500 450 550 18.5
20 140 140 1189 1189 457 368 419 190 785 24 500 450 550 18.5
22 140 170 1088 1118 508 406
216 845 28 600 550 660 23
22 140 170 1190 1220 508 406 457 216 845 28 600 550 660 23
25 140 170 1285 1315 508 457 508 216 852 30 600 550 660 23
25 140 170 1491 1521 508 457 508 216 880 30 600 550 660 23
28 140 210 1409 1479 610 500 560 254 958 35 740 680 800 23
28 140 210 1514 1584 610 560 630 254 958 35 740 680 800 23
28 140 210 1764 1834 610 710 900 254 958 35 740 680 800 23
28 170 210 1851 1891 710 900 1000 224 1045 35 940 880 1000 28
28 170 210 1851 1891 686 710 800 280 1045 35 740 680 800 24
32 170 210 2147 2187 800 1000 1120 250 1293 42 1080 1000 1150 28
1) MLA, MLB 2, MLB 8, MLC 2 2) MLB 4-6, M3C 4-8, MLD, ML3
86
9AKK105944 EN 02-2020 | ABB Motors and Generators
IMB14 (IM3601)
Motor size M N
P
S
T
71
85 70 105 6 2.5
80
100 80 120 6 3
90
115 95 140 8 3
100
130 110 160 8 3.5
112
130 110 160 8 3.5
132
165 130 200 10 3.5
The table gives the main dimension in mm. For detailed drawings please see our web pages www.abb.com/motors&generators.
ABB Motors and Generators | 9AKK105944 EN 02-2020
87
Dimension drawings
Process performance IE3 cast iron motors
L
HD
EC B B'
Foot-mounted motor IM 1001, IM B3
H
K A
DS
PN
LS
Flange-mounted motor IM 3001, IM B5 DS
D
F
GA
M S
45�
Sizes 80 to 200
S
M
LS
45� Sizes 225 to 450
Protective roof, variant code 005
IM1001, IMB3 and IM3001, IMB5
IM1001, IMB3
IM B5 (IM3001)
D Motor size 2
71
14
80
19
90SL_
24
90L_
24
100L_
28
100ML_
28
100LK_
28
112
28
132
38
160 1)
42
160 2)
42
180
48
200
55
225
55
250
60
280SM_
65
280ML_
65
315 SM_
65
315 ML_
65
315 LK_
65
355 SM_
70
355 ML_
70
355 LK_
70
400 L_
80
400 LK_
80
450
80
GA 4-8 2
F 4-8 2
14 16 16 5
19 21.5 21.5 6
24 27 27 8
24 27 27 8
28 31 31 8
28 31 31 8
28 31 31 8
28 31 31 8
38 41 41 10
42 45 45 12
42 45 45 12
48 51.5 51.5 14
55 59 59 16
60 59 64 16
65 64 69 18
75 69 79.5 18
75 69 79.5 18
80 69 85 18
90 69 95 18
90 69 95 18
100 74.5 106 20
100 74.5 106 20
100 74.5 106 20
110 85 126 22
100 85 106 22
120 85 127 22
E
L max
A
B
B1 C
HD K
MN
P
S
4-8 2
4-8 2
4-8
max
5
30 30 295 294 112 90 -
45 178 7
130 110 160 10
6
40 40 363 363 125 100 -
50 194 10 165 130 200 12
8
50 50 356 356 140 100 125 56 218 10 165 130 200 12
8
50 50 390 390 140 100 125 56 218 10 165 130 200 12
8
60 60 381 381 160 140 -
63 247 12 215 180 250 15
8
60 60 403 403 160 140 -
63 247 12 215 180 250 15
8
60 60 435 435 160 140 -
63 247 12 215 180 250 15
8
60 60 442 442 190 140 -
70 258 12 215 180 250 15
10 80 80 532 532 216 140 178 89 300 12 265 230 300 15
12 110 110 584 584 254 210 254 108 421 14.5 300 250 350 19
12 110 110 681 681 254 210 254 108 421 14.5 300 250 350 19
14 110 110 726 726 279 241 279 121 461 14.5 300 250 350 19
16 110 110 821 821 318 267 305 133 528 18.5 350 300 400 19
18 110 140 849 879 356 286 311 149 573 18.5 400 350 450 19
18 140 140 884 884 406 311 349 168 626 24 500 450 550 19
20 140 140 1088 1088 457 368 419 190 762 24 500 450 550 18
20 140 140 1189 1189 457 368 419 190 785 24 500 450 550 18
22 140 170 1174 1204 508 406 457 216 852 30 600 550 660 23
25 140 170 1285 1315 508 457 508 216 852 30 600 550 660 23
25 140 170 1491 1521 508 457 508 216 880 30 600 550 660 23
28 140 210 1409 1479 610 500 560 254 958 35 740 680 800 23
28 140 210 1514 1584 610 560 630 254 958 35 740 680 800 23
28 140 210 1764 1834 610 710 900 254 958 35 740 680 800 23
28 170 210 1851 1891 710 900 1000 224 1045 35 940 880 1000 28
28 170 210 1851 1891 686 710 800 280 1045 35 740 680 800 24
32 170 210 2147 2187 800 1000 1120 250 1293 42 1080 1000 1150 28
1) MLA 2 2) Other except MLA 2
88
9AKK105944 EN 02-2020 | ABB Motors and Generators
IMB14 (IM3601)
Motor size M N
P
S
T
71
85 70 105 6 2.5
80
100 80 120 6 3
90
115 95 140 8 3
100
130 110 160 8 3.5
112
130 110 160 8 3.5
132
165 130 200 10 3.5
The table gives the main dimension in mm. For detailed drawings please see our web pages www.abb.com/motors&generators.
ABB Motors and Generators | 9AKK105944 EN 02-2020
89
Dimension drawings
Process performance IE4 cast iron motors
L
HD
EC B B'
Foot-mounted motor IM 1001, IM B3
H
K A
DS
PN
LS
Flange-mounted motor IM 3001, IM B5 DS
D
F
GA
M S
45�
Sizes 80 to 200
S
M
LS
45� Sizes 225 to 450
Protective roof, variant code 005
IM1001, IMB3 and IM3001, IMB5
IM1001, IMB3
IM B5 (IM3001)
D Motor size 2
160 MLA 2 42
160 MLA 4-6, 42 MLB 2-4
160 MLB 6 pole
180 2-4 pole 48
180 MLA 6 -
200
55
225
55
250
60
280 SM_
65
280 MLA -
315 SM_
65
315 LK_
65
355 SM_
70
355 ML_
70
355 LK_
70
400 L_
80
400 LK_
80
450
80
GA 4-8 2
-
45
42 45
F 4-8 2 45 12 45 12
42 45 45 12
48 51.5 51.5 14
48 51.5 51.5 14
55 59 59 16
60 59 64 16
65 64 69 18
75 69 79.5 18
75 -
79.5 -
80 69 85 18
90 69 95 18
100 74.5 106 20
100 74.5 106 20
100 74.5 106 20
110 85 126 22
100 85 106 22
120 85 127 22
E
L max
A
B
B1 C
HD HD K
MN
P
S
4-8 2
4-8 2
4-8
1)
2)
12 110 110 584 584 254 210 254 108 421 -
14.5 300 250 350 19
12 110 110 681 681 254 210 254 108 421 -
14.5 300 250 350 19
12 110 110 721 721 254 210 254 108 421 -
14.5 300 250 350 19
14 110 110 726 726 279 241 279 121 461 -
14.5 300 250 350 19
14 110 110 766 766 279 241 279 121 461 -
14.5 300 250 350 19
16 110 110 822 822 318 267 305 133 528 -
18.5 350 300 400 19
18 110 140 849 879 356 286 311 149 574 -
18.5 400 350 450 19
18 140 140 884 884 406 311 349 168 626 -
24 500 450 550 19
20 140 140 1088 1088 457 368 419 190 762 -
24 500 450 550 18
20 -
140 -
1189 457 419 457 190 -
785 24 500 450 550 15
22 140 170 1174 1204 508 406 457 216 -
-
28 600 550 660 23
25 140 170 1491 1521 508 508 560 216 -
880 28 600 550 660 23
28 140 210 1409 1479 610 500 560 254 958 -
35 740 680 800 23
20 140 210 1514 1584 610 560 630 254 944 958 35 740 680 800 23
28 140 210 1764 1834 610 710 900 254 958 -
35 740 680 800 23
28 170 210 1851 1891 710 900 1000 224 1045 -
35 940 880 1000 28
28 170 210 1851 1891 686 710 800 280 1045 -
35 740 680 800 24
32 170 210 2147 2187 800 1000 1120 250 1293 -
42 1080 1000 1150 28
1) Terminal box 370 2) Terminal box 750
Tolerances A, B C, CA D
� 0.8 � 0.8 ISO k6 < � 50 mm ISO m6 > � 50 mm
Tolerances
F
ISO h9
H
+ 0 -0.5
N
ISO j6
The table gives the main dimension in mm. For detailed drawings please see our web pages www.abb.com/motors&generators.
90
9AKK105944 EN 02-2020 | ABB Motors and Generators
Accessories
Built-in brake (variant code 412)
Brake design Electromagnetic disc brakes are applied by the action of a set of springs and are released when voltage is applied to the brake coil. This means that the motor will brake automatically in case of any voltage failure, as significant safety feature. The brake is always functional, irrespective of the mounting position of the brake motor. Detailed view
1 Connection box, (with rectifier, optional) 2 Manual release (optional) 3 Modified N-end shield 4 V-ring seal 5 Adapter flange for brake 6 Brake 7 V-ring seal 8 Fan cover 9 Fan
Brake disc The brake linings are made of asbestos-free material. The linings are highly resistant to wear and have excellent thermal conductivity, providing consistent performance also in high temperatures. The brake disc withstands a large number of braking instances and is insensitive to dust and moisture. Note that changing from a used to a new disc will result in a different braking torque. Replacing the brake disc The brake disc must be replaced when the minimum permissible lining thickness has been reached. For minimum lining thickness, refer to the brake manufacturer's catalog. Rectifier Rectifier is a devise for DC brake applications. It is highly resistant to temperature changes as well as to voltage peaks and has additional protection for the auxiliary contact of the contactor. Thanks to its compact design, it can be placed inside the motor's terminal box. Rectifier is an optional element. Torque adjustment Reducing the torque of the brake is possible with most brake types. Refer to the brake manufacturer's catalog or contact ABB for more information. Manual release Manual release bolts are provided as standard. A manual release handle is an optional element. Manual release overrides the action of brake springs as long as it is applied. Though the manual release handle is optionally available for all motor sizes, it cannot be used in combination with the Pintsch Bamag brake type SFB. Brake rating plates The brake comes with two rating plates, one attached to the brake itself and another delivered loose, together with the motor. Variant code 412 is marked on the motor's rating plate (if it is listed among the five first codes on the motor order).
ABB Motors and Generators | 9AKK105944 EN 02-2020
91
J
J
J
01 Foot-mounted: IM B3 (IM1001), IM B6 (IM 1051), IM B7 (IM1061), IM B8 (IM 1071), IM V5 (IM 1011), IM V6 (IM 1031).
02 Flange-mounted: IM B5 (IM 3001), IM V1 (IM 3011), IM V3 (IM 3031), IM B14 (IM 3601), IM V18 (IM 3611), IM V19 (IM 3631).
03 Foot- and flangemounted: IM B35 (IM 2001), IM V15 (IM 2011), IM V36 (IM 2031).
Available brake types Motors can be fitted with recommended brakes from either Pintsch Bamag or Stromag, as seen in the tables below. Other brakes can be provided on request.
Brake type KFB 10 KFB 16 KFB 25 KFB 40 KFB 63 KFB 1000 KFB 1600 On request
Brake torque Nm 100 160 250 400 630 1000 1600
For motor size 160 160 - 180 180 - 225 200 - 250 225 - 280 280 - 315 315 - 355 355 - 450
Pintsch & Bamag, type KFB, IP 67, 110 V DC Electromagnetic Double-Disc Spring-Applied Brake
Brake type SFB 16 SFB 25 SFB 40 SFB 63 SFB 100 SFB 160 SFB 250 SFB 400 On request
Brake torque Nm 160 250 400 630 1000 1600 2500 4000
For motor size 200 - 225 200 - 225 225 - 250 250 280 - 315 315 - 355 355 - 400 400 450
Pintsch & Bamag,type SFB, IP 67, 110 V DC Electromagnetic Double-Disc Spring-Applied Brake
Brake type
Brake torque Nm
NFF 10
100
NFF 16
160
NFF 25
250
NFF 40
400
NFF 63
630
For sizes 280-450 on request
Stromag, type NFF, 110 V DC, IP66
For motor size 160 160 - 180 180 - 225 200 - 250 225 - 250
Options for the brake On new manufacture only �� Hand release (not possible for Pintsch Bamag
brake type SFB) �� Rectifier �� Micro switch �� Proximity switch (not possible for Stromag
brake) �� Standstill heater On request �� Special brake voltage �� Raised brake torque �� Combination with brake, separate cooling fan
and/or tacho �� For other variants, please contact ABB
Dimensions of brake motor L LC
__ 01
L LC
__ 02
L LC
__ 03
92
9AKK105944 EN 02-2020 | ABB Motors and Generators
Foot-mounted
Flange-mounted
Foot- and flange-mounted
Motor size Poles
L
LC
J
L
LC
J
L
LC
J
160 1)
2-8
773
511
372
773
511
372
773
511
372
160 2)
2-8
871
608
372
871
608
372
871
608
372
180
2-8
935
687
372
935
687
372
935
687
372
200
2-8
1011
695
460
1011
695
460
1011
695
460
225
2
1085
729
460
1085
729
460
1085
729
460
225
4-8
1115
729
460
1105
729
460
1115
729
460
250
2-8
1119
755
460
1119
755
460
1119
755
460
1)MLA-2, MLB-2, MLC-2, MLA-4, MLA-6, MLA-8 and MLB-8 -poles 2)MLD-2, MLE-2, MLB-4, MLC-4, MLD-4, MLB-6, MLC-6 and MLC-8 -poles Motor sizes 280 to 450 on request. Other dimensions same as Process performance cast iron motors sizes 180 to 250
ABB Motors and Generators | 9AKK105944 EN 02-2020
93
Accessories
Separate cooling
Axial fan, N-end Fan motors with an axial fan are available for motor sizes 71-450 and can be ordered can be ordered with variant code 183. The values here are given for 400 V, but technical data for other voltages can be found in MotSize.
Axial fan, N-end, for motor sizes 160 - 450, IE3
Main motor
Fan motor type (at 50 Hz)
Voltage V at 50 Hz
M3BP 160 250
M3BP 71MA 400 4 B14
M3BP 280 315 ML
M3BP 80MLE 400 4 B14
M3BP 315 LK - M3BP 90LB 400
355 SM
4 B14
M3BP 355 ML, LK
M3BP
400
100MLB 4
B14
Power kW 0.25
0.75
1.5
3.0
Current A 0.64
1.7
3.3
6.1
Axial fan, N-end, for motor sizes 71 - 132
Main mo- Fan motor
tor
type
M3BP 71 Wistro 132
M3BP 80 Wistro 156
M3BP 90 Wistro 169
M3BP 100 Wistro 187
M3BP 112 Wistro 210
M3BP 132 Wistro 250
Voltage Voltage
range at range at Power Cur-
50 Hz, V 60 Hz, V W
rent A
380 500
380 - 575 29
0,06
220 - 290 220 - 332 28 0,1
380 500
380 - 575 34
0,06
220 - 290 220 - 332 34 0,1
380 - 380 - 575 75 0,19 500
220 - 290 220 - 332 78 0,33
380 - 380 - 575 94 0,17 500
220 - 290 220 - 332 87 0,31
380 - 380 - 575 99 0,17 500
220 - 290 220 - 332 103 0,31
380 500
380 - 575 148 0,25
220 - 290 220 - 332 146 0,45
Fan on top, N-end The non-axial fan available for motor sizes 280 and above is a Ziehl-Abbegg fan with an integrated motor. This cooling option is suited for 400 V, 50 Hz networks and can be ordered with variant code 422.
MV at 50 Hz Main Fan mo- Voltmotor tor type age V
M3BP 280 ZiehlAbegg RH35
400 VY
460 VY
M3BP 315 ZiehlAbegg RH40
400 VY 460 VY
M3BP 355 ZiehlAbegg RH45
400 VY
460 VY
M3BP 400 ZiehlAbegg RH50
400 VY 460 VY
M3BP 450 ZiehlAbegg RH56
400 VY
460 VY
Power Freq. Hz kW
50
0.35
Current A
0.83
60
0.5
0.9
50
0.50 1.0
60
0.8
1.4
50
0.90 1.8
60
1.4
2.2
50
1.55 3.3
60
2.5
4.3
50
2.30 4.5
60
2.5
4.3
Axial fan, N-end, for motor sizes 160 - 450, IE2
Main motor
Fan motor type (at 50 Hz)
Voltage V at 50 Hz
M3BP 160 250
M3BP 71MA 400 4 B14
M3BP 280 315 ML
M3BP 80MD 400 4 B14
M3BP 315 LK - M3BP 90SLD 400
355 SM
4 B14
M3BP 355 ML M3BP 100LD 400
- 450 L
4 B14
Power Current
kW
A
0.25 0.64
0.75 1.83
1.5
3.0
3.0
6.3
Special motor and fan on top, N-end A special ABB fan motor type is available for motor sizes 280 and above. It is suited for environments where IP 65 is the required IP class or where the input voltage must be other than 360 � 420 V (50 Hz). The values here are given for 400 V, but technical data for other voltages can be found in MotSize.
94
9AKK105944 EN 02-2020 | ABB Motors and Generators
The centrifugal impeller used in the fan is a ZiehlAbegg impeller.This type of cooling can be ordered with variant code 514.
Special motor and fan on top, N-end, for motor sizes 280 - 450
Fan motor Voltage V
Main motor type
at 50 Hz
M3BP 280 M3BP 80 400
- 315
MD 4 B34
M3BP 355 M3BP 400
M3BP 90 400 SLD 4 B34
M3BP 100 400 LD 4 B34
M3BP 450 M3BP 112 400 MB 4 B34
Power kW Current A
0.75
1.83
1.5
3.0
3.0
6.3
4.0
8.2
ABB Motors and Generators | 9AKK105944 EN 02-2020
95
Accessories
Silencer for motor sizes 280 - 450
LV 80
AV
O
O
S DV
LVT
Both foot-mounted and flange-mounted motors can be fitted with a silencer to reduce noise level by about 5 - 6 dB(A). The silencer is painted blue and made of 2 mm steel sheet. The sound absorbing material is 40 mm thick polyurethane foam. On the rim there is a rubber strip for sealing on the floor. The silencer fits loosely over the motor. The variant code for ordering a silencer is 055.
Motor size
AV
LV
LVT
DV
O1)
280 SM_
681
1010
1090
616
50
315 SM_
760
1094
1191
697
60
315 ML_
760
1205
1302
697
60
315 LK_
760
1411
1508
697
60
355 SM_
850
1335
1441
777
65
355 ML_
850
1440
1546
777
65
355 LK_
850
1690
1796
777
65
400 L_
938
1750
1873
866
75
400 LK_
938
1750
1873
866
75
450 L_
1050
2110
2230
990
80
1) Clearance for motor cooling. 2) Clearance for removal of silencer. Note: The dimensions are only valid for standard foot-mounted motors.
S2) 762 852 852 852 958 958 958 1045 1045 1045
Weight kg 38 47 51 58 62 67 77 88 88 120
96
9AKK105944 EN 02-2020 | ABB Motors and Generators
Accessories
Slide rails for motor sizes 160 - 250
E H
B N
1 M
Ymax.
L
Xmax. 3
5
F
O
D C
2
4
G A
1 Motor | 2 Rail | 3 Movable adjusting bolt | 4 Fixing bolt, motor | 5 Plate A set of slide rails includes two complete rails with screws for mounting the motor on the rails. Screws for mounting the rails on the foundation are not included.Slide rails have unmachined lower surfaces and should, before tightening down, be supporter in a suitable manner. Slide rails can be ordered with article numbers shown in the table.
Article no.
Weight/
Motor size Type
3GZV103001- A B C D E F G H L M N O Xmax Ymax rail kg
Frame sizes 71 to 132 on request
160 - 180 TT180/12
-14
200 - 225 TT225/16
-15
250
TT280/20
-16
75 42 700 630 57 17 26 M12 120 M12 50 -
520
82 50 864 800 68 17 27 M16 140 M16 65 17 670
116 70 1072 1000 90 20 27 M18 150 M20 80 20 870
580 12.0 740 20.4 940 43.0
ABB Motors and Generators | 9AKK105944 EN 02-2020
97
Accessories
Slide rails for motor sizes 280 - 400
d h
(e2)
l1
l2 l3
a
b1
c e1
e3
g c
b2 e4
Slide rails for motor sizes 280 - 315.
d h
(e2)
l2
l1
l2 l3
f2 a
b4
c1 e1
e3
g c1
b1 h1 h2
f f1 b1 b2 e4 b5
Slide rails for motor sizes 355 - 400.
Note: Slide rails that do not fulfill the DIN standard are available for motor size 450 on request. A set of slide rails includes two complete rails with screws for mounting the motor on the rails. Screws for mounting the rails on the foundation are not included. Slide rails have unmachined lower surfaces and should be supported in a suitable manner before tightening down. Slide rails can be ordered with article numbers shown in the table.
Motor
size
Article no.
280
3GZF334730-55
315
3GZF334730-56
355 - 400 3GZF334730-57
l1 l2 l3 a 800 600 900 16 1000 720 1100 16 1250 485 1350 16
h b1 b2 c d 75 100 120 35 28 80 120 140 40 28 80 120 140 35 28
Bolts Horizontal Weight
e1 e2 e3 e4 to feet bolts 100 100 200 165 M20x90 M24x300 140 140 240 190 M24x100 M24x300 140 140 240 190 M24x100 M24x300
kg/2 pc 50 80 90
98
9AKK105944 EN 02-2020 | ABB Motors and Generators
Motors in brief
Cast iron motors, sizes 71 - 132
Motor size
Stator and end shields Material
Paint color shade
Corrosion class
Feet
Bearings
D-end
N-end
Axially locked bearings
Bearing seals
D-end
N-end
Lubrication
Measuring nipples for condition monitoring of the bearings
Rating plate
Material
Terminal box
Frame and cover
Corrosion class
Cover screws
Connections
Threaded openings
Terminals
Cable glands
Fan
Material
Fan cover
Material
Paint color shade
Corrosion class
Stator winding
Material
Insulation
Winding protection
Rotor winding
Material
Balancing method
Keyway
Drain holes
Enclosure
Cooling method
*) 6206-2Z/C3 in IE3
71
80
90
Cast iron
Munsell blue 8B 4.5/3.25
C3 (medium)
Integrated cast iron feet
6203-2Z/C3
6204-2Z/C3
6205-2Z/C3
6202-2Z/C3
6203-2Z/C3
6204-2Z/C3
Locked at D-end
V-ring
Labyrinth seal in IE2, V-ring in IE3
Permanently lubricated shielded bearings
Not included
100
6206-2Z/C3 6205-2Z/C3
Stainless steel
Cast iron
C3 (medium)
Zinc-electroplated steel
2xM16
2xM25
2xM25
6 terminals for connection with cable lugs (not included)
Cable flange included, glands as option
Glass-fiber reinforced polypropylene
Steel
Munsell blue 8B 4.5/3.25
C3 (medium)
Copper
Insulation class F. Temperature rise class B unless otherwise stated.
3 PTC thermistors, 150 �C
Pressure die-cast aluminum
Half-key balancing as standard
Closed keyway
Drain holes with closable plastic plugs, open on delivery
IP 55
IC 411
112
132
6206-2Z/C
6208-2Z/C3
6205-2Z/C3 *) 6208-2Z/C3
ABB Motors and Generators | 9AKK105944 EN 02-2020
99
Motors in brief
Cast iron motors, sizes 160 - 250
Motor size
Stator and end shields Material
Paint color shade
Corrosion class
Feet
Material
Bearings
D-end
N-end
Axially locked bearings
Bearing seals
D-end
N-end
Lubrication
Measuring nipples for condition monitoring of the bearings
Rating plate
Material
Terminal box
Frame and cover
Corrosion class
Cover screws
Connections
Cable entries
Terminals
Cable glands
Fan
Material
Fan cover
Material
Paint color shade
Corrosion class
Stator winding
Material
Insulation
Winding protection
Rotor winding
Material
Balancing method
Keyway
Drain holes
Enclosure
Cooling method
160
180
200
225
Cast iron
Munsell blue 8B 4.5/3.25
C3 (medium)
Integrated cast iron feet, bolted feet when terminal box on LHS/RHS
6309/C3
6310/C3
6312/C3
6313/C3
6209/C3
6209/C3
6210/C3
6212/C3
Locked at D-end
Gamma-ring
Gamma-ring
Regreasable bearings, regreasing nipples M6x1
Included
Stainless steel
Cast iron
C3 (medium)
Zinc-electroplated steel
2xM40, 2xM20
2xM63, 2xM20
6 terminals for connection with cable lugs (not included)
Cable flange included, glands as option
Glass-fiber reinforced polypropylene
Steel
Munsell blue 8B 4.5/3.25
C3 (medium)
Copper
Insulation class F. Temperature rise class B unless otherwise stated.
3 PTC thermistors, 150 �C
Pressure die-cast aluminum
Half-key balancing as standard
Closed keyway
Drain holes with closable plastic plugs, open on delivery
IP 55
IC 411
250
6315/C3 6213/C3
100
9AKK105944 EN 02-2020 | ABB Motors and Generators
Motors in brief
Cast iron motors, sizes 280 - 450
Motor size
Stator and end shields Material
Paint color shade
Corrosion class
Feet
Material
Bearings
D-end
2-pole
4-12-pole
N-end
2-pole
4-12-pole
Axially locked bearings
Bearing seals
D-end
N-end
Lubrication
Measuring nipples for condition monitoring of the bearings
Rating plate
Material
Terminal box
Frame and cover
Corrosion class
Cover screws
Connections
Cableentries
2-4-pole
6-8-pole
Fan Fan cover
Stator winding
Rotor winding Balancing method Keyway Drain holes Enclosure Cooling method
Terminals Cable glands Material Material Paint color shade Corrosion class Material Insulation Winding protection Material
280
315
355
Cast iron
Munsell blue 8B 4.5/3.25
C3 (medium)
Integrated cast iron feet
6316/C3
6316/C3
6316M/C3
6316/C3
6319/C3
6322/C3
6316/C3
6316/C3
6316M/C3
6316/C3
6316/C3
6316/C3
Locked at D-end
V-ring or labyrinth seal
V-ring or labyrinth seal
Regreasable bearings, regreasing nipples M10x1
Included
400
450
6317M/C3 6324/C3 6317M/C3 6319/C3
6317M/C3 6326M/C3 6317M/C3 6322/C3
Stainless steel
Cast iron
Cover steel
C3 (medium)
Steel
Zinc-electroplated steel
2xM63+2xM20
2xM63, 2x�4860+2xM20
2x�48-60, 60-80, 2xM20
2x�60-80 (2-6-pole), 2x�60-80, 2xM20 2xM2+0
2x�32-49, 48-60, 2M20
2x�48-60 (8-pole), 2xM20
See section Standard terminal box for detailed information.
6 terminals for connection with cable lugs (not included)
Cable flange, glands as option
Glass-fiber reinforced polypropylene
Steel
Munsell blue 8B 4.5/3.25
C3 (medium)
Copper
Insulation class F. Temperature rise class B unless otherwise stated.
3 PTC thermistors, 155 �C
Pressure die-cast aluminum
Half-key balancing
Open keyway
Drain holes with closable plastic plugs, open on delivery
IP 55
IC 411
ABB Motors and Generators | 9AKK105944 EN 02-2020
101
Motor construction
Exploded view, frame size 315
1 Stator frame 2 End shield, D-end 3 Screws for end shield, D-end 4 End shield, N-end 5 Screws for end shield, N-end 6 Rotor with shaft 7 Key, D-end 8 Terminal box 9 Terminal board 10 Intermediate flange 11 Screws for terminal box cover 12 Outer bearing cover, D-end
13 Valve disc with labyrinth seal, D-end; standard in 2-pole motors, V-ring in 4-8 pole motors 14 Bearing, D-end 15 Inner bearing cover, D-end 16 Screws for bearing cover 17 Outer bearing cover, N-end 18 Seal, N-end 19 Wave spring 20 Valve disc, N-end 21 Bearing, N-end 22 Inner bearing cover, N-end
23 Screws for bearing cover 24 Fan 25 Fan cover 26 Screws for fan cover 27 Rating plate 28 Lubrication plate 29 Grease nipple, D-end 30 Grease nipple, N-end 31 SPM nipple, D-end 32 SPM nipple, N-end
102
9AKK105944 EN 02-2020 | ABB Motors and Generators
Low voltage Process performance aluminum motors
104
Ordering information
105
Rating plates
106
Technical data IE2
106
400 V, 50 Hz
111
460V, 60Hz
115
Technical data IE3
115
400 V, 50 Hz
120
460V, 60Hz
123
Variant codes
128
Mechanical design
128
Motor frame and drain holes
129
Bearings
139
Terminal box
142
Dimension drawings
142
IE2 aluminum motors
143
IE3 aluminum motors, J/L-generation
144
IE3 aluminum motors, K-generation
145
Accessories
145
Slide rails
146
Aluminum motors in brief
146
Motor sizes 63 - 132
147
Motor sizes 160 - 280
ABB Motors and Generators | 9AKK105944 EN 02-2020
103
Ordering information
Explanation of the product code
Motor type
Motor size
Product code
Code for mounting arrangement, Voltage and frequency code, Generation code followed by variant codes
M3AA 112MB 3GAA 111 320 - ADE, 122, 003 etc.
1 2 3 4 5 67
8 9 10 11 12 13 14...
Positions 1 to 4 3GAA: Totally enclosed motor with aluminum stator frame
Positions 5 and 6
IEC size
06:
63
07:
71
08:
80
09:
90
10:
100
11:
112
13:
132
IEC size
16:
160
18:
180
20:
200
22:
225
25:
250
28:
280
Position 7
Pole pairs
1:
2 poles
2:
4 poles
3:
6 poles
4:
8 poles
5:
10 poles
6:
12 poles
7:
> 12 poles
8:
Two-speed motors
9:
Multi-speed motors
Positions 8 to 10 Running number
Position 11 - (dash)
Position 11 - (dash)
Position 12 (marked with black dot in data tables)
Mounting arrangement
A:
Foot-mounted motor
B:
Flange-mounted motor. Large flange with clearance
holes.
C:
Flange-mounted motor. Small flange with tapped
holes.
F:
Foot- and flange-mounted motor. Special flange.
Position 12 (marked with black dot in data tables)
H:
Foot- and flange-mounted motor. Large flange with
clearance holes.
J:
Foot- and flange-mounted motor. Small flange with
tapped holes.
N:
Flange-mounted (CI ring flange FF)
P:
Foot-and flange-mounted motor (CI ring flange FF)
V:
Flange-mounted motor. Special flange.
Position 13 (marked with black dot in data tables)
Voltage and frequency code
Single-speed motors
B:
380 V 50 Hz
D:
400 V, 415 V, 690 VY 50 Hz
E:
500 V 50 Hz
F:
500 VY 50 Hz
S:
230 V, 400 VY, 415 VY 50 Hz
T:
660 V 50 Hz
U:
690 V 50 Hz
X:
Other rated voltage, connection or frequency, 690 V
maximum
Two-speed motors
A:
220 V 50 Hz
B:
380 V 50 Hz
D:
400 V 50 Hz
E:
500 V 50 Hz
S:
230 V 50 Hz
X:
Other rated voltage, connection or frequency, 690 V
maximum
Remark: For voltage code X the variant code "209 Non-standard voltage or frequency (special winding)" must be ordered.
Position 14 Version A, B, C...:Generation code followed by variant codes
Efficiency values are given according to IEC 600342-1; 2014 For detailed dimension drawings please see our web-pages `www.abb.com/motors&generators' or contact ABB.
104
9AKK105944 EN 02-2020 | ABB Motors and Generators
Rating plates
The motor's main rating plate shows the motor's
01 Motor sizes 71 to 80.
performance values with various connections at
02 Motor sizes 90 to 132. nominal speed. The rating plate also shows the ef-
03 Motor sizes 160 to 280. ficiency level (IE2, IE3, or IE4), year of manufacture,
and the lowest nominal efficiency at 100, 75, and
50 % nominal load. The material of the rating plate
is aluminum as standard.
__ 01
__ 02
__ 03
ABB Motors and Generators | 9AKK105944 EN 02-2020
105
Technical data, 400 V 50 Hz
IE2 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3000 r/min = 2 poles
0.18
M3AA 63A 2
3GAA061311-��E
0.25
M3AA 63B 2
3GAA061312-��E
0.37
M3AA 71A 2
3GAA071311-��E
0.55
M3AA 71B 2
3GAA071312-��E
0.75
M3AA 80B 2
3GAA081312-��E
1.1
M3AA 80C 2
3GAA081313-��E
1.5
M3AA 90L 2
3GAA091500-��E
2.2
M3AA 90LB 2 3GAA091520-��E
3
M3AA 100LB 2 3GAA101520-��E
4
M3AA 112MB 2 3GAA111320-��E
5.5
M3AA 132SB 2 3GAA131120-��E
7.5
M3AA 132SC 2 3GAA131130-��E
11
M3AA 160MLA 2 3GAA161410-��G
15
M3AA 160MLB 2 3GAA161420-��G
18.5
M3AA 160MLC 2 3GAA161430-��G
22
M3AA 180MLA 2 3GAA181410-��G
30
M3AA 200MLA 2 3GAA201410-��G
37
M3AA 200MLB 2 3GAA201420-��G
45
M3AA 225SMA 2 3GAA221210-��G
55
M3AA 250SMA 2 3GAA251210-��G
75
M3AA 280SMA 2 3GAA281210-��G
90
1) M3AA 280SMB 2 3GAA281220-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
2790 2790 2800 2790 2895 2875 2900 2870 2920 2885 2915 2915 2938 2934 2932 2952 2956 2959 2961 2967 2968 2971
400 V 50 Hz 67.3 65.1 71.4 70.1 73.8 75.8 78.4 79.8 80.6 80.4 80.6 80.4 84.1 85.0 84.6 85.7 86.4 86.1 86.1 87.0 88.0 88.2 88.5 89.2 90.6 91.5 91.5 92.5 92.0 93.1 92.2 92.8 93.1 93.5 93.4 93.7 93.6 93.9 94.1 94.4 94.4 94.7 94.9 95.2
58.2 64.7 73.9 78.7 77.3 77.9 83.5 84.9 84.0 88.0 86.9 88.6 91.1 92.2 93.1 92.2 92.8 92.9 93.1 93.8 94.2 94.7
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.75 0.51 4.5 0.61 2.4 2.6 0.00015
0.76 0.66 4.8 0.86 2.8 2.7 0.00017
0.76 0.95 4.9 1.26 2.7 2.7 0.00035
0.78 1.29 5.3 1.88 2.9 2.8 0.00045
0.79 1.7 8.1 2.4
3.7 3.9 0.0009
0.80 2.4 7.8 3.6
3.6 3.5 0.0012
0.86 2.9 7.6 4.9
2.5 3.3 0.0024
0.86 4.4 6.9 7.3
2.8 3.2 0.0027
0.86 5.8 9.3 9.8
3.3 3.9 0.005
0.88 7.6 7.6 13.2 2.5 2.8 0.0062
0.82 11 7.9 18
2.6 3.6 0.016
0.88 13.6 7.6 24.5 2.2 3.2 0.022
0.90 19.2 7.5 35.7 2.4 3.1 0.044
0.90 26 7.5 48.8 2.5 3.3 0.053
0.92 31.5 7.5 60.2 2.9 3.4 0.063
0.87 39.5 7.7 71.1 2.8 3.3 0.076
0.90 51.4 7.7 96.9 2.7 3.1 0.178
0.90 63.5 8.2 119 3.0 3.3 0.196
0.88 78.8 6.7 145 2.5 2.5 0.244
0.88 95.8 6.8 177
2.2 2.7 0.507
0.89 128 7.1 241 2.5 2.8 0.583
0.89 153 7.8 289 2.6 3.2 0.644
Weight kg
Sound
pressure
Level LPA dB
4
60
4.2
61
4.9
58
5.9
58
10.5 60
11
60
16
60
18
63
25
62
30
68
52
73
52
73
91
69
105 69
123
69
132
69
210 72
225 72
263 74
304 75
389 75
425 75
1) Temperature rise class F
106
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE2 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3000 r/min = 2 poles
11
M3AA 132SMF 2 3GAA131260-��E
15
M3AA 132SMG 2 3GAA131270-��E
18.5
M3AA 132SMJ 2 3GAA131290-��E
22
M3AA 160MLD 2 3GAA161440-��G
27
M3AA 160MLE 2 3GAA161450-��G
30
M3AA 180MLB 2 3GAA181420-��G
45
M3AA 200MLC 2 3GAA201430-��G
55
1) M3AA 200MLD 2 3GAA201440-��G
55
M3AA 225SMB 2 3GAA221220-��G
75
1) M3AA 225SMC 2 3GAA221230-��G
75
1) M3AA 225SMD 2 3GAA221240-��G
75
M3AA 250SMB 2 3GAA251220-��G
80
1) M3AA 225SMD 2 3GAA221240-��G
90
1) M3AA 250SMC 2 3GAA251230-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
2900 2905 2895 2933 2939 2950 2957 2953 2961 2969 2967 2970 2964 2971
400 V 50 Hz 90.3 90.5 90.4 90.8 91.1 92.0 91.7 92.8 92.2 93.1 92.7 93.5 93.3 93.8 93.8 94.4 93.9 94.3 94.4 94.6 94.4 94.6 94.5 94.8 94.4 94.8 95.0 95.3
89.4 90.0 92.1 92.8 93.1 93.3 93.2 94.3 93.6 94.0 94.0 94.3 94.3 94.9
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.87 20.2 8.5 36.2 2.7 3.7 0.0186
0.84 28.5 9.1 49.3 3.3 4.0 0.02
0.89 32.9 9.7 61
3.2 4.3 0.0256
0.90 38 8.1 71.6 3.2 3.6 0.063
0.90 46.4 8.8 87.7 3.4 3.8 0.072
0.88 53 7.9 97.1 2.8 3.3 0.092
0.90 78.2 8.1 145 3.1 3.3 0.196
0.89 95 7.8 177
2.9 3.3 0.217
0.88 96 6.5 177
2.4 2.5 0.274
0.84 136 7.4 241 3.2 3.1 0.309
0.87 131 7.7 241 3.2 3.0 0.329
0.89 128 7.6 241 2.8 3.1 0.583
0.87 140 7.3 257 3.0 2.8 0.329
0.89 153 7.6 289 2.5 3.1 0.644
Weight kg
Sound
pressure
Level LPA dB
77
68
81
69
93
68
123
69
145 69
149 69
225 72
241 72
286 74
312
74
317
74
351 75
317
74
386 75
1) Temperature rise class F
ABB Motors and Generators | 9AKK105944 EN 02-2020
107
Technical data, 400 V 50 Hz
IE2 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1500 r/min = 4 poles
0.12
M3AA 63A 4
3GAA062311-��E
0.18
M3AA 63B 4
3GAA062312-��E
0.25
M3AA 71A 4
3GAA072311-��E
0.37
M3AA 71B 4
3GAA072312-��E
0.55
M3AA 80A 4
3GAA082311-��E
0.75
M3AA 80E 4
3GAA082315-��E
1.1
M3AA 90LB 4 3GAA092520-��E
1.5
M3AA 90LD 4 3GAA092540-��E
2.2
M3AA 100LC 4 3GAA102530-��E
3
M3AA 100LD 4 3GAA102540-��E
4
M3AA 112MB 4 3GAA112320-��E
5.5
M3AA 132M 4 3GAA132300-��E
7.5
M3AA 132MA 4 3GAA132310-��E
11
M3AA 160MLA 4 3GAA162410-��G
15
M3AA 160MLB 4 3GAA162420-��G
18.5
M3AA 180MLA 4 3GAA182410-��G
22
M3AA 180MLB 4 3GAA182420-��G
30
M3AA 200MLA 4 3GAA202410-��G
37
M3AA 225SMA 4 3GAA222210-��G
45
M3AA 225SMB 4 3GAA222220-��G
55
M3AA 250SMA 4 3GAA252210-��G
75
M3AA 280SMA 4 3GAA282210-��G
85
M3AA 280SMB 4 3GAA282220-��G
90
1) M3AA 280SMB 4 3GAA282220-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1360 1370 1365 1375 1375 1425 1435 1435 1450 1445 1445 1465 1460 1466 1470 1477 1475 1480 1479 1480 1480 1478 1480 1478
400 V 50 Hz 55.0 51.3 63.5 61.0 65.1 66.0 69.7 71.9 72.8 76.1 79.8 80.4 83.7 83.7 84.2 84.1 86.4 86.2 85.7 86.1 86.7 86.5 89.0 89.5 88.7 89.4 90.4 91.6 91.4 92.4 91.9 92.9 92.3 93.3 93.2 94.0 93.4 93.9 93.9 94.3 94.4 94.9 94.3 94.9 94.8 95.3 94.6 95.4
43.0 54.3 62.7 71.1 75.2 77.9 81.7 81.9 84.1 85.1 85.2 88.6 88.9 91.4 92.2 92.7 93.2 93.7 93.4 93.9 94.6 94.6 95.0 95.2
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.64 0.49 3.2 0.84 2.4 2.5 0.00027
0.61 0.67 3.7 1.25 2.8 2.9 0.00034
0.76 0.72 4.0 1.74 2.0 2.1 0.00066
0.79 0.96 3.8 2.5
2.0 2.2 0.0008
0.77 1.41 4.5 3.8
1.8 2.2 0.0013
0.72 1.88 6.6 5
3.5 3.6 0.002
0.78 2.4 6.6 7.3
2.9 3.2 0.0043
0.76 3.3 7.0 9.9
3.1 3.5 0.0048
0.79 4.6 7.3 14.4 2.8 3.4 0.009
0.79 6.3 7.0 19.8 2.4 3.0 0.011
0.75 8.8 7.3 26.4 3.1 3.4 0.0126
0.79 10.9 6.3 36
1.9 2.6 0.038
0.79 14.7 6.4 49
1.8 2.6 0.048
0.84 20.9 6.8 71.6 2.2 2.8 0.081
0.83 28.5 7.1 97.4 2.6 3.0 0.099
0.84 34.5 7.2 119 2.6 2.9 0.166
0.84 40.9 7.3 142 2.6 3.0 0.195
0.84 55.2 7.4 193 2.8 3.0 0.309
0.84 68 7.1 238 2.6 2.9 0.356
0.85 81.3 7.5 290 2.8 3.2 0.44
0.85 98.9 7.0 354 2.6 2.9 0.765
0.85 135 7.1 484 2.8 3.0 0.866
0.84 153 8.0 548 3.4 3.6 0.941
0.84 163 7.7 581 3.2 3.4 0.941
Weight kg
Sound
pressure
Level LPA dB
3.7
51
4.2
54
5.2
45
5.9
45
8.5
50
15
54
16
50
17
50
25
54
28
63
34
64
48
66
59
63
99
62
118
62
146 62
163
62
218 63
240 66
273 66
314 67
389 67
418 67
418 67
1) Temperature rise class F
Output kW
Motor type
Product code
1500 r/min = 4 poles
15
M3AA 132SMH 4 3GAA132280-��E
18.5
M3AA 160MLC 4 3GAA162430-��G
22
1) M3AA 160MLD 4 3GAA162440-��G
30
1) M3AA 180MLC 4 3GAA182430-��G
37
M3AA 200MLB 4 3GAA202420-��G
45
1) M3AA 200MLC 4 3GAA202430-��G
55
M3AA 225SMC 4 3GAA222230-��G
64
M3AA 225SMD 4 3GAA222240-��G
75
1) M3AA 250SMB 4 3GAA252220-��G
90
1) M3AA 250SMC 4 3GAA252230-��G
1) Temperature rise class F
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1455 1469 1464 1474 1479 1479 1478 1480 1478 1478
400 V 50 Hz 90.6 91.0 91.4 92.5 91.6 92.6 92.3 93.5 93.4 94.4 93.6 94.4 94.0 94.7 94.2 94.6 94.4 95.1 94.6 95.3
90.3 92.3 92.7 93.5 94.4 94.2 94.5 94.1 94.8 95.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.77 29.8 7.1 98.4 2.4 2.9 0.0517
0.84 34.7 7.6 120 3.0 3.2 0.11
0.85 41.3 6.9 143 2.5 2.9 0.125
0.83 56.5 7.3 194 2.7 2.9 0.217
0.85 67.2 7.1 238 2.6 2.9 0.343
0.83 83.6 7.5 290 2.9 3.2 0.366
0.85 99.3 7.4 355 2.9 3.1 0.474
0.85 115 8.2 412 3.3 3.3 0.542
0.85 134 7.3 484 2.8 3.1 0.866
0.84 163 7.4 581 3.1 3.3 0.941
Weight kg
Sound
pressure
Level LPA dB
82
67
127
62
140 62
177
62
234 63
246 63
287 66
314 66
350 67
377 67
108
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE2 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1000 r/min = 6 poles
0.09
M3AA 63A 6
3GAA063311-��E
0.12
M3AA 63B 6
3GAA063312-��E
0.18
M3AA 71A 6
3GAA073311-��E
0.25
M3AA 71B 6
3GAA073312-��E
0.37
M3AA 80A 6
3GAA083311-��E
0.55
M3AA 80B 6
3GAA083312-��E
0.75
M3AA 90LB 6 3GAA093520-��E
1.1
M3AA 90LD 6 3GAA093540-��E
1.5
M3AA 100LC 6 3GAA103530-��E
2.2
M3AA 112MB 6 3GAA113320-��E
3
M3AA 132S 6 3GAA133100-��E
4
M3AA 132MB 6 3GAA133320-��E
5.5
M3AA 132MC 6 3GAA133330-��E
7.5
M3AA 160MLA 6 3GAA163410-��G
11
M3AA 160MLB 6 3GAA163420-��G
15
M3AA 180MLA 6 3GAA183410-��G
18.5
M3AA 200MLA 6 3GAA203410-��G
22
M3AA 200MLB 6 3GAA203420-��G
30
M3AA 225SMA 6 3GAA223210-��G
37
M3AA 250SMA 6 3GAA253210-��G
45
1) M3AA 280SMA 6 3GAA283210-��G
55
1) M3AA 280SMB 6 3GAA283220-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 890 50.7 48.5 42.0 890 52.3 48.8 41.5 885 59.5 61.1 56.5 895 64.0 63.6 59.5 905 68.0 70.7 68.3 905 68.7 71.8 69.7 930 77.6 78.0 75.6 935 78.2 79.2 77.5 945 80.3 81.4 80.7 955 81.9 81.8 79.2 960 83.3 82.9 80.5 975 86.4 85.8 83.1 965 86.1 85.6 83.0 975 88.5 89.8 89.7 972 89.3 90.6 90.5 977 90.5 91.5 91.0 988 91.6 92.3 91.7 987 92.0 92.9 92.8 986 92.6 93.3 92.8 989 93.1 93.8 93.4 988 93.2 94.0 93.9 988 93.2 94.1 94.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.62 0.41 2.8 0.96 2.0 2.2 0.00042
0.60 0.55 3.0 1.29 2.2 2.4 0.00052
0.71 0.61 3.1 1.94 1.7 1.9 0.00092
0.71 0.79 3.3 2.6
2.2 2.2 0.0012
0.73 1.07 3.6 3.9
1.6 2.1 0.002
0.73 1.58 3.3 5.8
1.6 1.8 0.0026
0.71 1.96 4.0 7.7
2.0 2.3 0.0048
0.66 2.94 4.2 11.2 2.2 2.6 0.0056
0.73 3.6 3.9 15.1 1.7 2.0 0.009
0.72 5.3 5.2 21.9 1.8 2.2 0.01
0.65 7.69 4.3 29.8 1.6 2.3 0.031
0.70 9.4 7.3 39.2 2.1 4.4 0.045
0.67 13.3 6.2 54.3 2.5 2.8 0.049
0.79 15.4 7.4 73.4 1.7 3.2 0.087
0.79 22.5 7.5 108 1.9 2.9 0.114
0.77 31 5.8 146 1.8 2.7 0.168
0.80 36.4 6.7 178 2.3 2.9 0.382
0.82 42 6.6 212 2.2 2.8 0.448
0.83 56.2 7.0 290 2.6 2.9 0.663
0.82 69.9 6.8 357 2.4 2.7 1.13
0.84 82.9 6.8 434 2.4 2.6 1.37
0.84 101 7.1 531 2.6 2.8 1.5
Weight kg
Sound
pressure
Level LPA dB
4.2
48
4.5
53
5.5
42
6.5
42
9
47
10
47
18
44
20
44
26
49
34
56
46
57
54
57
59
61
98
59
125 59
148 59
196 63
218 63
266 63
294 63
378 63
404 63
1) Temperature rise class F
Output kW
Motor type
Product code
1000 r/min = 6 poles
15
M3AA 160MLC 6 3GAA163430-��G
18.5
M3AA 180MLB 6 3GAA183420-��G
30
1) M3AA 200MLC 6 3GAA203430-��G
37
M3AA 225SMB 6 3GAA223220-��G
45
1) M3AA 225SMC 6 3GAA223230-��G
45
M3AA 250SMB 6 3GAA253220-��G
55
1) M3AA 250SMC 6 3GAA253230-��G
1) Temperature rise class F
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 971 89.7 91.2 975 90.7 92.0 985 92.0 93.1 985 93.1 94.0 984 92.6 93.9 989 93.4 94.1 988 93.2 94.1
91.2 92.0 92.9 94.0 94.0 93.9 94.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.77 31.3 7.3 147 1.8 3.6 0.131
0.79 37.2 5.8 181 1.7 2.7 0.198
0.83 56.7 6.9 290 2.3 2.8 0.531
0.83 69.1 6.6 358 2.3 2.6 0.821
0.83 84.4 6.4 436 2.3 2.6 0.821
0.83 83.7 7.0 434 2.5 2.7 1.37
0.84 101 7.1 531 2.6 2.8 1.5
Weight kg
Sound
pressure
Level LPA dB
138 59
162
59
245 63
300 63
300 63
341 63
367 63
ABB Motors and Generators | 9AKK105944 EN 02-2020
109
Technical data, 400 V 50 Hz
IE2 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
750 r/min = 8 poles
0.09
M3AA 71A 8
3GAA074001-��E
0.12
M3AA 71B 8
3GAA074002-��E
0.18
M3AA 80A 8
3GAA084001-��E
0.25
M3AA 80B 8
3GAA084002-��E
0.37
M3AA 90S 8
3GAA094100-��E
0.55
M3AA 90L 8
3GAA094500-��E
0.75
M3AA 100LA 8 3GAA104510-��E
1.1
M3AA 100LB 8 3GAA104520-��E
2.2
M3AA 132S 8 3GAA134100-��E
3
M3AA 132M 8 3GAA134300-��E
4
M3AA 160 MLA 8 3GAA164410-��G
5.5
M3AA 160 MLB 8 3GAA164420-��G
11
M3AA 180 MLA 8 3GAA184410-��G
15
M3AA 200 MLA 8 3GAA204410-��G
18.5
M3AA 225 SMA 8 3GAA224210-��G
22
M3AA 225 SMB 8 3GAA224220-��G
30
M3AA 250 SMA 8 3GAA254210-��G
37
M3AA 280 SMA 8 3GAA284210-��E
75
M3AA 160 MLC 8 3GAA164430-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 675 48.8 45.2 665 51.5 49.0 690 57.2 55.4 690 61.4 60.0 695 59.4 55.9 660 61.7 59.5 720 70.7 67.1 695 76.0 74.9 715 77.7 79.2 715 79.3 78.8 728 84.0 85.1 726 84.6 85.9 731 86.9 88.5 737 90.1 91.3 739 91.0 92.0 738 91.6 92.3 742 92.3 92.8 740 92.2 93.0 727 86.0 87.3
37.8 41.9 48.8 54.0 47.8 53.0 59.9 70.9 77.6 75.5 83.6 84.8 87.9 90.8 91.5 92.0 92.2 92.6 86.5
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.57 0.46 2.5 1.27 2.2 2.1 0.00092
0.60 0.56 2.5 1.72 2.2 2.1 0.0012
0.61 0.74 2.9 2.4
2.3 2.3 0.0018
0.60 0.97 3.1 3.4
2.5 2.5 0.0024
0.54 1.6 2.7 5
1.7 2.1 0.0032
0.58 2.3 2.5 7.6
1.5 1.6 0.0043
0.47 3.2 3.9 9.9
2.5 3.3 0.0069
0.66 3.1 3.4 15.1 1.7 2.2 0.0082
0.65 6.2 3.4 29.3 1.3 1.9 0.031
0.64 8.5 3.2 40
1.2 1.8 0.037
0.67 10.2 5.4 52.4 1.5 2.6 0.068
0.67 13.9 5.6 72.3 1.4 2.6 0.085
0.67 27.3 4.4 143 1.8 2.6 0.214
0.74 32.4 5.3 194 2.0 2.4 0.45
0.73 40.1 5.2 239 2.0 2.3 0.669
0.74 46.8 5.5 284 2.0 2.3 0.722
0.71 66 5.8 386 2.6 2.4 1.4
0.74 78.1 5.6 477 2.4 2.3 1.51
0.65 19.3 4.7 98.5 1.5 2.8 0.132
Weight kg
Sound
pressure
Level LPA dB
5.5
40
6.5
43
8.5
45
9.5
50
13
52
16
52
20
46
23
53
46
56
53
58
84
59
98
59
175
59
217
60
266 63
279 63
340 63
403 63
137
59
Output kW
Motor type
Product code
750 r/min = 8 poles
0.18
M3AA 71C 8
3GAA074003-��E
0.37
M3AA 80C 8
3GAA084003-��E
0.75 1) M3AA 90LF 8 3GAA094560-��E
1.5
1) M3AA 100LG 8 3GAA104570-��E
3.8 1) M3AA 132MF 8 3GAA134360-��E
18.5
M3AA 200 MLB 8 3GAA204420-��E
30
M3AA 225 SMC 8 3GAA224230-��E
37
M3AA 250 SMB 8 3GAA254220-��E
45
1) M3AA 250 SMC 8 3GAA254230-��G
1) Temperature rise class F
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 660 49.8 48.5 41.7 685 63.1 63.2 58.1 635 58.5 57.8 51.2 685 70.7 70.9 67.3 710 76.7 79.3 78.1 739 90.1 90.9 90.3 737 91.6 92.6 92.4 740 92.7 93.6 93.4 738 92.2 93.4 93.4
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.63 0.82 2.7 2.6
2.1 2.0 0.0015
0.62 1.36 3.3 5.1
2.3 2.3 0.0031
0.60 3.1 2.7 10.5 1.7 2.0 0.0048
0.64 4.7 3.1 20.9 1.9 2.0 0.009
0.68 10.5 3.7 51.1 1.4 2.5 0.049
0.74 40 5.4 239 2.1 2.3 0.53
0.73 64.7 5.6 388 2.3 2.4 0.828
0.73 78.9 5.4 477 2.6 2.3 1.51
0.74 95.1 5.6 582 2.3 2.4 1.51
Weight kg
Sound
pressure
Level LPA dB
7
40
11
45
18
43
26
46
54
68
245 60
300 63
367 63
367 63
110
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 460 V 60 Hz
IE2 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3600 r/min = 2 poles
0.25
M3AA 63B 2
3GAA061312-��E
0.37
M3AA 71A 2
3GAA071311-��E
0.55
M3AA 71B 2
3GAA071312-��E
0.75
M3AA 80B 2
3GAA081312-��E
1.1
M3AA 80C 2
3GAA081313-��E
1.5
M3AA 90L 2
3GAA091500-��E
2.2
M3AA 90LB 2 3GAA091520-��E
3
M3AA 100LB 2 3GAA101520-��E
4
M3AA 112MB 2 3GAA111320-��E
5.5
M3AA 132SB 2 3GAA131120-��E
7.5
M3AA 132SC 2 3GAA131130-��E
11
M3AA 160MLA 2 3GAA161410-��G
15
M3AA 160MLB 2 3GAA161420-��G
18.5
M3AA 160MLC 2 3GAA161430-��G
22
M3AA 180MLA 2 3GAA181410-��G
30
M3AA 200MLA 2 3GAA201410-��G
37
M3AA 200MLB 2 3GAA201420-��G
45
M3AA 225SMA 2 3GAA221210-��G
55
M3AA 250SMA 2 3GAA251210-��G
75
M3AA 280SMA 2 3GAA281210-��G
90
1) M3AA 280SMB 2 3GAA281220-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
3420 3400 3420 3505 3490 3510 3480 3530 3490 3515 3525 3547 3545 3543 3559 3562 3564 3566 3571 3568 3575
460 V 60 Hz 73.8 71.6 77.5 77.5 81.9 82.6 82.5 81.4 82.6 81.9 85.1 85.0 85.8 85.9 87.5 86.7 87.6 88.4 88.5 87.8 89.5 89.2 91.4 91.5 92.1 92.3 92.4 92.8 92.4 92.4 93.1 92.8 93.4 93.2 93.5 93.2 93.8 93.5 94.4 94.3 94.9 94.7
65.4 74.3 80.7 77.5 78.7 82.9 84.2 84.5 87.8 85.3 87.6 90.3 91.2 92.1 91.1 91.4 91.7 91.7 92.1 93.2 93.7
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.71 0.59 5.7 0.69 3.6 3.5 0.00017
0.71 0.84 5.9 1.03 3.2 3.5 0.00035
0.75 1.12 6.6 1.53 3.2 3.7 0.00045
0.80 1.43 9.6 2
3.7 4.5 0.0009
0.78 2.1 9.1 3
3.9 4.2 0.0012
0.84 2.6 8.4 4
2.8 3.8 0.0024
0.85 3.7 7.9 6
2.6 3.7 0.0027
0.84 5.1 10.0 8.1
4.1 4.6 0.005
0.91 6.2 8.1 10.9 2.7 3.0 0.0062
0.86 9
8.5 14.9 2.5 4.1 0.016
0.89 12 8.7 20.3 2.3 3.7 0.022
0.90 16.7 8.6 29.6 2.6 3.5 0.044
0.90 22.4 8.7 40.4 2.7 3.8 0.053
0.92 27.2 8.7 49.8 3.1 3.8 0.063
0.87 34.3 8.8 59
3.0 3.8 0.076
0.90 44.9 8.7 80.4 2.8 3.4 0.178
0.89 55.8 9.2 99.1 3.1 3.7 0.196
0.88 68.6 7.7 120 2.6 2.7 0.244
0.88 83.2 7.7 147 2.3 3.0 0.507
0.89 112 8.0 200 2.6 3.2 0.583
0.89 133 8.9 240 2.8 3.5 0.644
Weight kg
Sound
pressure
Level LPA dB
4.2
4.9
61
5.9
61
10.5 63
11
63
16
63
18
66
25
65
30
71
52
76
52
76
91
73
105 73
123
73
132
73
210 76
225 76
263 78
304 79
389 79
425 79
1) Temperature rise class F
Output kW
Motor type
Product code
3600 r/min = 2 poles
11
M3AA 132SMF 2 3GAA131260-��E
15
M3AA 132SMG 2 3GAA131270-��E
17.5
M3AA 132SMG 2 3GAA131270-��E
18.5
M3AA 132SMJ 2 3GAA131290-��E
21.5
M3AA 132SMJ 2 3GAA131290-��E
22
M3AA 160MLD 2 3GAA161440-��G
30
M3AA 160MLE 2 3GAA161450-��G
30
M3AA 180MLB 2 3GAA181420-��G
45
M3AA 200MLC 2 3GAA201430-��G
55
M3AA 200MLD 2 3GAA201440-��G
55
M3AA 225SMB 2 3GAA221220-��G
75
M3AA 225SMC 2 3GAA221230-��G
75
M3AA 250SMB 2 3GAA251220-��G
80
M3AA 225SMD 2 3GAA221240-��G
90
M3AA 250SMC 2 3GAA251230-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
3504 3510 3495 3500 3486 3546 3539 3558 3563 3560 3567 3573 3575 3570 3575
460 V 60 Hz 90.9 90.3 90.7 90.4 91.0 91.5 91.6 91.8 91.4 92.2 92.4 92.8 92.5 93.2 93.0 93.1 93.4 93.3 94.3 94.4 93.9 93.7 94.3 94.1 94.5 94.4 94.5 94.4 95.1 95.0
88.3 88.8 90.5 90.9 92.0 92.0 92.7 92.4 92.2 93.4 92.4 93.0 93.3 93.3 94.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.94 17.2 9.0 30
2.8 4.3 0.0187
0.89 23.6 9.5 40.7 3.5 4.6 0.02
0.90 27 8.9 47.8 2.8 3.8 0.02
0.91 28.2 10.5 50.3 3.3 5.3 0.0256
0.89 33.2 9.7 58.9 2.9 4.3 0.0256
0.91 32.8 9.3 59.2 3.4 4.1 0.063
0.91 44.6 9.1 80.9 3.3 3.9 0.072
0.89 45.4 9.2 80.5 3.1 3.8 0.092
0.88 68.7 9.2 120 3.2 3.7 0.196
0.89 82.2 9.0 147 3.1 3.7 0.217
0.89 82.6 7.5 147 2.5 2.8 0.274
0.86 116 8.7 200 3.3 3.4 0.309
0.89 111 8.6 200 2.9 3.4 0.583
0.88 120 8.4 213 3.1 3.2 0.329
0.89 133 8.6 240 2.7 3.4 0.644
Weight kg
Sound
pressure
Level LPA dB
77
68
81
72
81
69
93
71
93
68
123
73
145 73
149 73
225 76
241 76
286 78
312
78
351 79
317
78
386 79
ABB Motors and Generators | 9AKK105944 EN 02-2020
111
Technical data, 460 V 60 Hz
IE2 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1800 r/min = 4 poles
0.12
M3AA 63A 4
3GAA062311-��E
0.18
M3AA 63B 4
3GAA062312-��E
0.25
M3AA 71A 4
3GAA072311-��E
0.37
M3AA 71B 4
3GAA072312-��E
0.55
M3AA 80A 4
3GAA082311-��E
0.75
M3AA 80D 4
3GAA082314-��E
1.1
M3AA 90LB 4 3GAA092520-��E
1.5
M3AA 90LD 4 3GAA092540-��E
2.2
M3AA 100LC 4 3GAA102530-��E
3
M3AA 100LD 4 3GAA102540-��E
4
M3AA 112MB 4 3GAA112320-��E
5.5
M3AA 132M 4 3GAA132300-��E
7.5
M3AA 132MA 4 3GAA132310-��E
11
M3AA 160MLA 4 3GAA162410-��G
15
M3AA 160MLB 4 3GAA162420-��G
18.5
M3AA 180MLA 4 3GAA182410-��G
22
M3AA 180MLB 4 3GAA182420-��G
30
M3AA 200MLA 4 3GAA202410-��G
37
M3AA 225SMA 4 3GAA222210-��G
45
M3AA 225SMB 4 3GAA222220-��G
55
M3AA 250SMA 4 3GAA252210-��G
75
M3AA 280SMA 4 3GAA282210-��G
90
M3AA 280SMB 4 3GAA282220-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1690 1700 1685 1695 1695 1730 1740 1750 1760 1750 1745 1769 1764 1772 1775 1781 1780 1783 1782 1784 1782 1782 1782
460 V 60 Hz 57.9 53.6 66.6 63.3 69.3 68.7 74.4 74.9 77.7 78.7 82.6 82.5 84.6 83.7 85.4 84.1 87.5 86.9 88.2 87.5 87.6 87.5 89.7 89.6 89.5 89.6 91.3 91.6 92.2 92.4 92.5 92.8 93.1 93.4 93.8 94.0 93.6 93.5 94.2 94.1 95.2 95.4 94.7 94.8 94.9 95.0
45.3 55.8 64.0 71.9 76.6 79.8 80.7 80.6 84.2 85.6 85.7 87.9 88.3 90.5 91.5 91.9 92.5 93.1 92.5 93.1 94.9 94.1 94.3
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.56 0.46 3.6 0.68 2.9 3.3 0.00027
0.55 0.61 4.0 1
3.4 3.7 0.00034
0.68 0.66 4.8 1.41 2.3 2.7 0.00066
0.72 0.86 5.3 2
2.2 2.6 0.0008
0.74 1.2 5.5 3
2.0 2.8 0.0013
0.70 1.62 7.0 4.1
3.0 3.9 0.0016
0.76 2.1 7.6 6
3.1 3.9 0.0043
0.72 3
8.2 8.1
3.8 4.6 0.0048
0.75 4.2 9.1 11.9 3.4 4.5 0.009
0.80 5.3 8.2 16.3 3.6 4.2 0.011
0.77 7.4 8.2 21.8 3.3 3.7 0.0126
0.79 9.5 7.3 29.8 2.0 3.0 0.038
0.81 12.8 7.5 40.6 1.9 3.0 0.048
0.83 18.2 7.7 59.2 2.4 3.2 0.081
0.83 24.6 8.0 80.6 2.7 3.3 0.099
0.83 30.2 8.2 99.1 2.8 3.2 0.166
0.83 35.7 8.3 118 2.8 3.3 0.195
0.83 48.2 8.4 160 3.0 3.3 0.309
0.84 59 8.1 198 2.8 3.2 0.356
0.85 70.5 8.6 240 2.7 3.3 0.44
0.84 86.3 8.0 294 2.8 3.3 0.765
0.85 116 8.2 401 3.0 3.3 0.866
0.84 141 9.0 482 3.6 3.8 0.941
Weight kg
Sound
pressure
Level LPA dB
3.7
4.2
5.2
48
5.9
48
8.5
53
10
53
16
53
17
53
25
57
28
66
34
67
48
69
59
66
99
66
118
66
146 66
163
66
218 67
240 70
273 70
314 71
389 71
418 71
Output kW
Motor type
Product code
1800 r/min = 4 poles
11
M3AA 132SMF 4 3GAA132260-��E
15
M3AA 132SMH 4 3GAA132280-��E
18.5
M3AA 160MLC 4 3GAA162430-��G
22
M3AA 160MLD 4 3GAA162440-��G
30
M3AA 180MLC 4 3GAA182430-��G
37
M3AA 200MLB 4 3GAA202420-��G
45
M3AA 200MLC 4 3GAA202430-��G
55
M3AA 225SMC 4 3GAA222230-��G
64
M3AA 225SMD 4 3GAA222240-��G
75
M3AA 250SMB 4 3GAA252220-��G
90
M3AA 250SMC 4 3GAA252230-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1765 1760 1774 1770 1777 1783 1783 1782 1783 1782 1776
460 V 60 Hz 91.5 91.2 91.7 91.5 92.4 92.7 92.5 93.2 93.2 93.6 94.2 94.6 94.4 94.5 94.4 94.6 94.4 94.4 94.8 95.0 95.2 95.3
89.6 90.2 92.0 92.6 93.0 94.1 93.9 93.8 93.4 94.4 94.6
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.80 18.7 8.8 59.5 2.2 3.5 0.0433
0.78 26 8.2 81.54 2.6 3.4 0.0517
0.83 30.2 8.7 99.5 3.3 3.6 0.11
0.84 35.4 7.8 118 2.7 3.3 0.125
0.83 48.6 8.3 161 2.9 3.3 0.217
0.84 58.6 8.5 198 2.8 3.3 0.343
0.83 72 8.6 241 3.2 3.6 0.366
0.85 86 8.5 294 3.1 3.4 0.474
0.85 100 9.4 342 3.5 3.7 0.542
0.85 116 8.4 401 3.1 3.5 0.866
0.84 141 8.6 483 3.5 3.7 0.941
Weight kg
Sound
pressure
Level LPA dB
83
68
82
70
127
66
140 66
177
66
234 67
246 67
287 70
314 70
350 71
377 71
112
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 460 V 60 Hz
IE2 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1200 r/min = 6 poles
0.09
M3AA 63A 6
3GAA063311-��E
0.12
M3AA 63B 6
3GAA063312-��E
0.18
M3AA 71A 6
3GAA073311-��E
0.25
M3AA 71B 6
3GAA073312-��E
0.37
M3AA 80A 6
3GAA083311-��E
0.55
M3AA 80B 6
3GAA083312-��E
0.75
M3AA 90LB 6 3GAA093520-��E
1.1
M3AA 90LD 6 3GAA093540-��E
1.5
M3AA 100LC 6 3GAA103530-��E
2.2
M3AA 112MB 6 3GAA113320-��E
3
M3AA 132S 6 3GAA133100-��E
4
M3AA 132MB 6 3GAA133320-��E
5.5
M3AA 132MC 6 3GAA133330-��E
7.5
M3AA 160MLA 6 3GAA163410-��G
11
M3AA 160MLB 6 3GAA163420-��G
15
M3AA 180MLA 6 3GAA183410-��G
18.5
M3AA 200MLA 6 3GAA203410-��G
22
M3AA 200MLB 6 3GAA203420-��G
30
M3AA 225SMA 6 3GAA223210-��G
37
M3AA 250SMA 6 3GAA253210-��G
45
M3AA 280SMA 6 3GAA283210-��G
55
M3AA 280SMB 6 3GAA283220-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1110 1110 1110 1110 1125 1120 1140 1141 1150 1160 1161 1177 1165 1179 1177 1181 1190 1189 1189 1191 1190 1190
460 V 60 Hz 53.4 48.9 55.1 50.6 65.3 64.1 68.8 67.2 73.4 73.5 74.6 75.0 79.6 79.2 80.3 80.0 83.3 83.3 84.4 83.8 85.4 84.3 87.3 86.1 87.6 86.5 89.6 90.1 90.4 91.0 91.6 91.9 92.2 92.2 92.7 93.1 93.2 93.4 93.6 93.8 93.8 94.2 94.0 94.3
40.6 42.2 58.4 61.5 69.8 71.7 75.4 77.1 81.4 80.6 81.0 82.9 83.4 88.9 90.0 91.1 91.1 92.2 92.4 93.1 93.6 93.7
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.55 0.38 3.2 0.76 2.4 2.6 0.00042
0.53 0.51 3.4 1.02 2.6 3.0 0.00052
0.64 0.54 3.8 1.54 2.1 2.5 0.00092
0.61 0.74 4.1 2.1
2.7 3.0 0.0012
0.69 0.91 4.3 3.1
1.8 2.6 0.002
0.68 1.36 4.0 4.6
1.8 2.4 0.0026
0.67 1.71 4.5 6.2
2.1 2.7 0.0048
0.64 2.6 5.0 9.1
2.4 3.1 0.0056
0.70 3.2 4.4 12.4 1.8 2.4 0.009
0.65 5
5.9 18.1 2.5 3.3 0.01
0.67 6.84 4.7 24.3 1.7 2.8 0.031
0.69 8.3 8.0 32.4 2.2 5.1 0.045
0.67 11.8 6.8 44.96 2.7 3.2 0.049
0.77 13.6 7.4 60.7 1.7 3.2 0.087
0.77 19.8 8.4 89.2 2.0 3.4 0.114
0.75 27.4 6.5 121 1.9 3.1 0.168
0.79 31.8 7.5 148 2.5 3.2 0.382
0.81 36.7 7.5 176 2.5 3.2 0.448
0.82 49.2 8.0 240 2.8 3.2 0.663
0.81 61.2 7.6 296 2.6 3.0 1.13
0.83 72.5 7.6 361 2.6 2.9 1.37
0.83 88.4 8.1 441 2.9 3.1 1.5
Weight kg
Sound
pressure
Level LPA dB
4.2
4.5
5.5
42
6.5
42
9
47
10
47
18
44
20
47
26
49
34
56
46
60
54
60
59
64
98
63
125 63
148 63
196 67
218 67
266 67
294 67
378 67
404 67
Output kW
Motor type
Product code
1200 r/min = 6 poles
15
M3AA 160MLC 6 3GAA163430-��G
18.5
M3AA 180MLB 6 3GAA183420-��G
30
M3AA 200MLC 6 3GAA203430-��G
37
M3AA 225SMB 6 3GAA223220-��G
45
M3AA 225SMC 6 3GAA223230-��G
45
M3AA 250SMB 6 3GAA253220-��G
55
M3AA 250SMC 6 3GAA253230-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1176 1180 1188 1188 1187 1191 1189
460 V 60 Hz 90.7 91.3 92.0 92.5 93.0 93.3 93.8 94.1 93.6 94.1 93.9 94.2 94.0 94.3
90.5 91.8 92.5 93.5 93.6 93.5 93.7
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.75 27.6 8.1 121 1.9 4.1 0.131
0.78 32.3 6.6 149 1.9 3.0 0.198
0.83 48.7 8.0 241 2.6 3.2 0.531
0.83 59.6 7.5 297 2.5 3.0 0.821
0.82 73.5 7.3 362 2.5 2.9 0.821
0.82 73.3 7.9 360 2.7 3.1 1.37
0.83 88.4 8.1 441 2.9 3.1 1.5
Weight kg
Sound
pressure
Level LPA dB
138 63
162
63
245 67
300 67
300 67
341 67
367 67
ABB Motors and Generators | 9AKK105944 EN 02-2020
113
Technical data, 460 V 60 Hz
IE2 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
900 r/min = 8 poles
0.055
M3AA 63B 8
3GAA064002-��E
0.09
M3AA 71A 8
3GAA074001-��E
0.12
M3AA 71B 8
3GAA074002-��E
0.18
M3AA 80A 8
3GAA084001-��E
0.25
M3AA 80B 8
3GAA084002-��E
0.37
M3AA 90S 8
3GAA094100-��E
0.55
M3AA 90L 8
3GAA094500-��E
0.75
M3AA 100LA 8 3GAA104510-��E
1.1
M3AA 100LB 8 3GAA104520-��E
1.5
M3AA 112M 8 3GAA114300-��E
2.2
M3AA 132S 8 3GAA134100-��E
3
M3AA 132M 8 3GAA134300-��E
4
M3AA 160MLA 8 3GAA164410-��G
5.5
M3AA 160MLB 8 3GAA164420-��G
7.5
M3AA 160MLC 8 3GAA164430-��G
11
M3AA 180MLA 8 3GAA184410-��G
15
M3AA 200MLA 8 3GAA204410-��G
18.5
M3AA 225SMA 8 3GAA224210-��G
22
M3AA 225SMB 8 3GAA224220-��G
30
M3AA 250SMA 8 3GAA254210-��G
37
M3AA 280SMA 8 3GAA284210-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
460 V 60 Hz 850 36.9 31.7 840 50.8 46.2 830 54.3 50.3 850 59.5 56.2 850 63.5 60.7 851 62.9 58.7 811 65.5 62.5 865 74.2 71.3 860 77.4 75.9 855 78.6 77.4 870 79.0 78.2 865 81.0 81.8 882 85.8 85.7 881 86.4 86.6 882 87.7 87.9 885 88.6 89.2 890 91.5 91.8 890 92.1 92.3 890 92.4 92.6 893 93.0 93.0 892 93.1 93.2
24.3 38.3 42.6 49.0 53.9 50.4 55.5 64.6 71.0 73.1 74.9 79.8 83.4 84.6 86.3 87.8 90.8 91.2 91.6 91.9 92.3
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.42 0.45 2.0 0.62 2.7 3.2 0.00045
0.50 0.44 2.9 1.02 2.7 2.7 0.00092
0.52 0.53 2.9 1.38 2.7 2.8 0.0012
0.55 0.69 3.3 2
2.6 2.9 0.0018
0.54 0.91 3.6 2.8
2.8 3.1 0.0024
0.48 1.56 3.0 4.1
1.9 2.7 0.0032
0.49 2.15 2.8 6.1
1.6 2.1 0.0043
0.51 2.4 4.2 8.2
2.6 3.4 0.0069
0.57 3.1 4.0 12.2 2.2 2.9 0.0082
0.61 3.9 4.2 16.7 2.1 2.8 0.01
0.64 5.4 4.1 24.1 1.4 2.4 0.031
0.68 6.8 3.2 33.1 1.2 2.0 0.037
0.64 9.1 5.9 43.3 1.6 3.0 0.068
0.65 12.2 6.2 59.6 1.5 3.0 0.085
0.63 17 5.1 81.2 1.5 3.2 0.132
0.66 23.5 5.1 118 2.0 2.9 0.214
0.71 28.5 5.9 160 2.3 2.7 0.45
0.72 35 5.9 198 2.2 2.5 0.669
0.73 40.8 6.3 236 2.2 2.6 0.722
0.70 57.8 6.6 320 2.8 2.7 1.4
0.73 68.3 6.4 396 2.6 2.6 1.51
Weight kg
Sound
pressure
Level LPA dB
5.3
5.5
40
6.5
43
8.5
45
9.5
50
13
55
16
55
20
46
23
53
28
55
46
59
53
61
84
63
98
63
137
63
175
63
217
64
266 67
279 67
340 67
403 67
Output kW
Motor type
Product code
900 r/min = 8 poles
0.18
M3AA 71C 8
3GAA074003-��E
0.37
M3AA 80C 8
3GAA084003-��E
0.75
M3AA 90LF 8 3GAA094560-��E
1.5
M3AA 100LG 8 3GAA104570-��E
2
M3AA 112MF 8 3GAA114360-��E
4.4 1) M3AA 132MF 8 3GAA134360-��E
18.5
M3AA 200MLB 8 3GAA204420-��G
30
M3AA 225SMC 8 3GAA224230-��G
37
M3AA 250SMB 8 3GAA254220-��G
45
M3AA 250SMC 8 3GAA254230-��G
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
460 V 60 Hz 830 53.5 50.1 845 65.8 64.0 810 66.1 63.5 845 76.6 75.6 850 79.1 79.1 860 80.0 82.1 891 91.2 91.4 889 92.8 93.1 891 93.6 93.9 891 93.4 93.9
42.4 57.8 57.1 71.7 75.7 80.9 90.2 92.4 93.3 93.4
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.56 0.75 3.1 2
2.5 2.6 0.0015
0.57 1.23 3.7 4.1
2.6 2.8 0.0031
0.52 2.9 3.0 8.8
2.0 2.5 0.0048
0.60 4
3.7 16.9 2.1 2.5 0.009
0.63 5
4.0 22.4 1.9 2.6 0.0126
0.69 10 3.8 48.8 1.3 2.6 0.049
0.72 35.3 6.1 198 2.3 2.6 0.53
0.72 56.3 6.4 322 2.6 2.7 0.828
0.72 68.9 6.1 396 2.8 2.6 1.51
0.74 81.7 6.4 482 2.5 2.7 1.51
Weight kg
Sound
pressure
Level LPA dB
7
42
11
47
18
46
26
49
32
60
54
71
245 64
300 67
367 67
367 67
1) Temperature rise class F
114
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE3 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3000 r/min = 2 poles
0.75
M3AA 80B 2
3GAA081612-��J
1.1
M3AA 80C 2
3GAA081613-��J
1.1
M3AA 80C 2
3GAA081613-��J
1.5
M3AA 90L 2
3GAA091500-��J
2.2
M3AA 90LB 2 3GAA091520-��J
3
M3AA 100LB 2 3GAA101520-��J
4
M3AA 112MB 2 3GAA111320-��J
5.5
M3AA 132SB 2 3GAA131120-��J
7.5
M3AA 132SC 2 3GAA131130-��J
22
M3AA 180MLA 2 3GAA181410-��L
30
M3AA 200MLA 2 3GAA201410-��L
37
M3AA 200MLB 2 3GAA201420-��L
45
M3AA 225SMA 2 3GAA221210-��L
55
M3AA 250SMA 2 3GAA251210-��L
75
M3AA 280SMA 2 3GAA281210-��L
90
1) M3AA 280SMB 2 3GAA281220-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
2885 2871 2871 2906 2903 2896 2888 2901 2909 2944 2957 2952 2955 2966 2971 2968
400 V 50 Hz 80.7 80.9 82.7 82.8 82.7 82.8 84.2 84.7 85.9 86.3 87.1 88.2 88.1 89.4 89.2 89.9 90.1 91.3 92.7 93.5 93.3 94.0 93.7 94.5 94.0 94.5 94.3 94.6 94.7 95.1 95.0 95.4
80.2 80.7 80.7 84.6 84.9 88.0 89.6 90.1 91.5 93.4 93.9 94.5 94.4 94.1 94.8 95.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.76 1.7 7.5 2.5
4.1 4.6 0.002
0.80 2.4 7.6 3.66 4.0 4.2 0.002
0.80 2.4 7.6 3.66 4.0 4.2 0.002
0.89 2.8 7.9 4.9
2.3 3.3 0.0027
0.79 4.7 7.4 7.2
3.2 3.8 0.003
0.90 5.4 8.4 9.8
3.2 3.9 0.0057
0.91 7.1 8.4 13.2 3.2 4.0 0.0104
0.91 9.7 7.9 18.1 2.3 3.4 0.0154
0.90 13.1 8.3 24.6 3.0 3.9 0.0173
0.90 38 8.4 71.4 3.2 3.7 0.071
0.88 52.7 8.7 96.9 3.0 3.8 0.104
0.88 64.7 8.7 120 3.1 3.7 0.115
0.89 77.6 8.0 145 2.9 3.3 0.214
0.88 95.6 7.4 177
2.9 2.9 0.274
0.90 127 7.9 241 2.8 3.3 0.644
0.90 151 8.4 290 2.7 3.4 0.644
Weight kg
Sound
pressure
Level LPA dB
9.4
60
11
60
11
60
16
60
18
63
31
62
35
68
56
68
63
70
133
74
171
74
185 74
254 77
302 79
413 81
421 81
1) Temperature rise class F
Output kW
Motor type
Product code
1500 r/min = 4 poles
0.75
M3AA 80ME 4 3GAA082614-��J
1.1
M3AA 90LB 4 3GAA092520-��J
1.5
M3AA 90LD 4 3GAA092540-��J
2.2
M3AA 100LC 4 3GAA102530-��J
3
M3AA 100LD 4 3GAA102540-��J
4
M3AA 112MB 4 3GAA112320-��J
5.5
M3AA 132M 4 3GAA132300-��J
7.5
M3AA 132MA 4 3GAA132310-��J
18.5
M3AA 180MLA 4 3GAA182410-��L
30
M3AA 200MLA 4 3GAA202410-��L
37
M3AA 225SMA 4 3GAA222210-��L
55
M3AA 250SMA 4 3GAA252210-��L
75
M3AA 280SMA 4 3GAA282210-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1424 1437 1445 1455 1445 1451 1460 1462 1473 1476 1480 1478 1482
400 V 50 Hz 82.5 83.2 84.1 83.7 85.3 85.0 86.7 86.6 87.9 88.4 88.6 89.4 89.6 90.1 90.6 91.1 92.6 93.3 93.6 94.1 93.9 94.8 94.6 94.9 95.0 95.5
81.8 81.2 82.7 84.6 87.8 89.0 89.6 90.5 93.1 94.1 94.8 94.8 95.3
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.76 1.74 6.1 5
2.5 3.4 0.0016
0.78 2.46 8.0 7.32 3.3 3.8 0.007
0.75 3.34 7.6 9.95 3.4 4.1 0.007
0.80 4.6 7.9 14.4 3.2 4.0 0.011
0.83 5.9 7.7 19.8 2.8 3.5 0.014
0.77 8.6 7.6 26.3 3.1 4.1 0.018
0.82 11 6.6 35.9 2.2 3.3 0.031
0.79 15.6 6.7 48.9 2.5 3.4 0.037
0.82 35.1 8.3 120 3.1 3.5 0.124
0.82 56.5 7.4 195 2.5 3.2 0.191
0.82 69.3 7.5 239 2.8 2.9 0.362
0.84 99.9 7.7 355 3.3 3.3 0.536
0.82 138 7.9 483 3.6 3.8 0.941
Weight kg
Sound
pressure
Level LPA dB
13.1 54
17
50
20
50
25
54
32
63
34
64
48
66
59
63
137
67
193
62
249 68
331
71
410 73
ABB Motors and Generators | 9AKK105944 EN 02-2020
115
Technical data, 400 V 50 Hz
IE3 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1000 r/min = 6 poles
0.75
M3AA 90LB 6 3GAA093520-��J
1.1
M3AA 90LD 6 3GAA093540-��J
1.5
M3AA 100LC 6 3GAA103530-��J
2.2
M3AA 112MB 6 3GAA113320-��J
3
M3AA 132S 6 3GAA133100-��J
4
M3AA 132MA 6 3GAA133310-��J
5.5
M3AA 132MC 6 3GAA133330-��J
18.5
M3AA 200MLA 6 3GAA203410-��L
37
M3AA 250SMA 6 3GAA253210-��L
45
M3AA 280SMA 6 3GAA283210-��L
55
M3AA 280SMB 6 3GAA283220-��L
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 930 78.9 78.9 76.7 928 81.0 81.7 81.2 962 84.7 85.0 83.3 957 84.3 85.0 84.0 972 85.6 85.5 83.6 964 86.8 88.0 87.8 970 88.5 89.4 88.8 980 91.7 92.5 92.0 985 93.3 93.7 93.4 991 93.7 94.1 93.6 989 94.1 94.7 94.4
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.68 2.08 3.9 7.7
2.3 2.7 0.007
0.77 2.71 4.0 11.3 1.7 2.2 0.007
0.69 3.6 5.3 14.9 2.5 3.1 0.014
0.65 5.9 5.3 21.9 2.3 3.0 0.018
0.69 7.4 5.3 29.5 1.8 3.0 0.031
0.75 8.9 4.5 39.1 1.8 3.0 0.039
0.67 13.3 6.1 54.2 2.3 3.1 0.044
0.75 38.8 6.4 180 2.1 3.1 0.22
0.80 71.5 7.0 359 2.7 3.0 0.813
0.81 85.5 7.6 434 2.9 3.3 1.5
0.80 105 7.1 531 3.0 3.1 1.49
Weight kg
Sound
pressure
Level LPA dB
17
44
19
44
28
49
33
56
48
57
60
61
64
61
177
65
320 68
399 68
400 68
116
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE3 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3000 r/min = 2 poles
0.75
M3AA 80MB 2 3GAA081320-��K
1.1
M3AA 80MC 2 3GAA081330-��K
1.5
M3AA 90LB 2 3GAA091520-��K
2.2
M3AA 90LC 2 3GAA091530-��K
3
M3AA 100LC 2 3GAA101530-��K
4
M3AA 112MB 2 3GAA111320-��K
5.5
M3AA 132SB 2 3GAA131120-��K
7.5
M3AA 132SC 2 3GAA131130-��K
11
M3AA 160MLA 2 3GAA161410-��K
15
M3AA 160MLB 2 3GAA161420-��K
18.5
M3AA 160MLC 2 3GAA161430-��K
22
M3AA 180MLA 2 3GAA181410-��K
30
M3AA 200MLA 2 3GAA201410-��K
37
M3AA 200MLB 2 3GAA201420-��K
45
M3AA 225SMA 2 3GAA221210-��K
55
M3AA 250SMA 2 3GAA251210-��K
75
1) M3AA 280SMA 2 3GAA281210-��K
90
1) M3AA 280SMB 2 3GAA281220-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
2894 2883 2906 2900 2896 2888 2901 2909 2943 2947 2949 2956 2958 2961 2968 2968 2971 2968
400 V 50 Hz 83.1 82.8 83.9 83.6 86.1 86.6 87.4 88.8 87.9 88.9 88.5 89.8 89.3 90.0 90.7 91.8 91.2 92.0 91.9 92.2 92.4 93.0 92.7 93.1 93.3 93.7 93.7 94.1 94.0 94.0 94.3 93.7 94.7 95.1 95.0 95.4
80.0 82.0 86.5 88.9 88.7 90.0 90.2 92.0 91.6 91.8 92.6 92.7 93.4 93.8 93.0 93.6 94.8 95.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.74 1.74 7.9 2.4
3.7 4.2 0.0008
0.81 2.3 7.9 3.6
3.7 4.2 0.001
0.89 2.8 7.9 4.9
2.3 3.3 0.0027
0.89 4
8.3 7.2
2.9 3.5 0.0032
0.90 5.4 8.4 9.8
3.2 3.9 0.0057
0.91 7.1 8.4 13.2 3.2 4.0 0.0104
0.91 9.7 7.9 18.1 2.3 3.4 0.0154
0.90 13.1 8.3 24.6 3.0 3.9 0.0173
0.91 19.1 7.2 35.57 2.6 3.6 0.057
0.88 26.7 8.2 48.6 3.2 4.2 0.063
0.90 32.1 9.0 59.9 3.3 3.9 0.076
0.90 37.7 7.8 71.0 3.4 3.8 0.11
0.89 52 7.7 96.8 2.7 3.1 0.178
0.88 64.4 8.2 119 3.0 3.3 0.196
0.87 79.6 7.3 145 3.2 3.1 0.296
0.89 94.8 6.8 177
2.4 3.0 0.426
0.90 127 7.9 241 2.8 3.3 0.644
0.90 151 8.4 290 2.7 3.4 0.644
Weight kg
Sound
pressure
Level LPA dB
9.5
57
10.5 56
17
60
20
60
28
62
38
68
58
68
63
70
106 69
123
69
137
73
176
73
225 72
241 72
326 76
351 76
412 81
420 81
1) Temperature rise class F
Output kW
Motor type
Product code
3000 r/min = 2 poles
22
M3AA 160MLD 2 3GAA161440-��K
30
M3AA 180MLB 2 3GAA181420-��K
37
1) M3AA 180MLC 2 3GAA181430-��K
45
M3AA 200MLC 2 3GAA201430-��K
55
M3AA 225SMB 2 3GAA221220-��K
75
1) M3AA 225SMC 2 3GAA221230-��K
75
1) M3AA 250SMB 2 3GAA251220-��K
90
1) M3AA 250SMC 2 3GAA251230-��K
1) Temperature rise class F
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
2944 2957 2952 2955 2966 2966 2971 2968
400 V 50 Hz 92.7 93.5 93.3 94.0 93.7 94.5 94.0 94.6 94.3 94.6 94.7 94.8 94.7 95.1 95.0 95.4
93.4 93.9 94.5 94.5 94.1 94.1 94.8 95.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.90 38 8.4 71.4 3.2 3.7 0.071
0.88 52.7 8.7 96.9 3.0 3.8 0.104
0.88 64.7 8.7 120 3.1 3.7 0.115
0.89 77.6 8.0 145 2.9 3.3 0.214
0.88 95.6 7.4 177
2.9 2.9 0.274
0.88 129 8.1 241 3.3 3.0 0.329
0.90 127 7.9 241 2.8 3.3 0.644
0.90 151 8.4 290 2.7 3.4 0.644
Weight kg
Sound
pressure
Level LPA dB
131
74
162
74
176
74
250 77
288 79
328 79
405 81
414 81
ABB Motors and Generators | 9AKK105944 EN 02-2020
117
Technical data, 400 V 50 Hz
IE3 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1500 r/min = 4 poles
0.75
M3AA 80ME 4 3GAA082350-��K
1.1
M3AA 90LC 4 3GAA092530-��K
1.5
M3AA 90LD 4 3GAA092540-��K
2.2
M3AA 100LE 4 3GAA102550-��K
3
M3AA 100LF 4 3GAA102560-��K
4
M3AA 112MB 4 3GAA112320-��K
5.5
M3AA 132MB 4 3GAA132320-��K
7.5
M3AA 132MC 4 3GAA132330-��K
11
M3AA 160MLA 4 3GAA162410-��K
15
M3AA 160MLB 4 3GAA162420-��K
18.5
M3AA 180MLA 4 3GAA182410-��K
22
M3AA 180MLB 4 3GAA182420-��K
30
M3AA 200MLA 4 3GAA202410-��K
37
M3AA 225SMA 4 3GAA222210-��K
45
M3AA 225SMB 4 3GAA222220-��K
55
M3AA 250SMA 4 3GAA252210-��K
75
M3AA 280SMA 4 3GAA282210-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1440 1442 1439 1454 1452 1454 1464 1464 1477 1474 1481 1480 1481 1482 1482 1485 1482
400 V 50 Hz 84.0 83.9 85.6 85.1 85.3 84.7 89.1 89.5 88.8 89.2 88.6 89.1 89.6 90.2 90.6 91.0 91.4 91.8 92.1 92.2 92.6 93.2 93.3 94.1 93.6 93.9 93.9 94.1 94.2 94.4 95.4 95.9 95.0 95.5
81.9 83.4 82.8 88.6 88.3 88.6 89.5 90.9 91.1 91.3 92.9 94.1 93.4 93.8 94.0 95.7 95.3
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.76 1.68 7.9 4.9
3.3 3.7 0.0027
0.80 2.3 7.9 7.2
3.3 3.9 0.0055
0.78 3.2 8.2 9.9
3.5 4.0 0.0055
0.83 4.3 8.9 14.5 3.1 4.1 0.0144
0.83 5.9 9.0 19.7 3.5 4.2 0.0144
0.75 8.7 7.5 26.3 3.5 3.7 0.0176
0.78 11.4 7.0 35.9 2.8 3.9 0.0295
0.81 14.7 7.7 48.9 2.5 3.6 0.0414
0.82 21.1 7.6 71.3 2.6 3.3 0.11
0.81 29 7.8 97.2 3.0 3.7 0.135
0.83 34.9 7.2 119 2.8 3.0 0.219
0.82 41.5 8.2 141 2.8 3.1 0.217
0.84 55.1 7.5 193 2.7 3.2 0.385
0.83 68.9 7.2 239 3.1 3.1 0.427
0.84 82.3 8.0 290 3.2 3.5 0.525
0.85 97.8 7.9 353 3.0 3.3 0.933
0.82 138 7.9 483 3.6 3.8 0.941
Weight kg
Sound
pressure
Level LPA dB
13.5 54
19
56
19
51
36
54
36
54
44
59
68
70
68
64
126 61
140 61
177
60
176
62
246 63
315 67
316
66
376 67
409 73
Output kW
Motor type
Product code
1500 r/min = 4 poles
18.5
M3AA 160MLC 4 3GAA162430-��K
30
M3AA 180MLC 4 3GAA182430-��K
37
1) M3AA 200MLB 4 3GAA202420-��K
55
M3AA 225SMC 4 3GAA222230-��K
75
M3AA 250SMB 4 3GAA252220-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1473 1476 1480 1478 1482
400 V 50 Hz 92.6 93.4 93.6 94.2 93.9 94.8 94.6 94.9 95.0 95.4
93.1 94.2 94.8 94.8 95.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.82 35.1 8.3 120 3.1 3.5 0.124
0.82 56.5 7.4 195 2.5 3.2 0.191
0.82 69.3 7.5 239 2.8 2.9 0.362
0.84 99.9 7.7 355 3.3 3.3 0.536
0.84 135 7.9 483 3.3 3.5 0.941
Weight kg
Sound
pressure
Level LPA dB
135 67
176
62
244 68
318 71
389 73
1) Temperature rise class F
118
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 400 V 50 Hz
IE3 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1000 r/min = 6 poles
0.75
M3AA 90LD 6 3GAA093540-��K
1.1
M3AA 100LE 6 3GAA103550-��K
1.5
M3AA 100LF 6 3GAA103560-��K
2.2
M3AA 112MC 6 3GAA113330-��K
3
M3AA 132MC 6 3GAA133330-��K
4
M3AA 132MD 6 3GAA133340-��K
5.5
M3AA 132ME 6 3GAA133350-��K
7.5
M3AA 160MLA 6 3GAA163410-��K
11
M3AA 160MLB 6 3GAA163420-��K
15
M3AA 180MLA 6 3GAA183410-��K
18.5
M3AA 200MLA 6 3GAA203410-��K
22
M3AA 200MLB 6 3GAA203420-��K
30
M3AA 225SMA 6 3GAA223210-��K
37
M3AA 250SMA 6 3GAA253210-��K
45
M3AA 280SMA 6 3GAA283210-��K
55
M3AA 280SMB 6 3GAA283220-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 937 80.3 80.5 79.5 963 84.0 85.0 84.0 969 85.7 85.9 84.2 967 87.2 87.9 87.1 978 88.5 88.8 87.7 973 88.5 89.3 89.1 973 89.5 90.2 89.6 980 90.8 91.5 91.0 979 91.2 91.8 91.1 987 92.2 92.5 91.5 990 92.8 93.2 92.6 990 93.3 93.7 93.1 989 94.1 94.7 94.5 991 94.4 94.9 94.7 991 93.7 94.1 93.6 989 94.1 94.8 94.5
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.76 1.78 4.6 7.6
2.1 2.3 0.0055
0.69 2.6 5.6 10.9 2.3 3.1 0.0138
0.65 3.7 7.0 14.7 3.3 4.1 0.0138
0.69 5.2 6.5 21.7 2.4 3.5 0.0187
0.69 7
6.2 29.2 2.0 3.0 0.0402
0.72 9.1 5.6 39.2 1.9 2.7 0.0402
0.74 12 5.8 53.9 2.0 2.9 0.039
0.78 15.2 7.9 73
1.7 3.3 0.114
0.74 23.5 8.5 107 2.2 3.9 0.131
0.77 30.4 5.5 146 1.7 2.7 0.225
0.77 37.3 7.5 178 2.6 3.2 0.448
0.79 43 7.8 212 2.6 3.2 0.531
0.81 56.8 7.9 289 2.8 3.1 0.813
0.83 68 7.7 356 2.7 2.9 1.49
0.81 85.5 7.6 434 2.9 3.3 1.5
0.80 105 7.1 531 3.0 3.1 1.49
Weight kg
Sound
pressure
Level LPA dB
19
55
35
49
35
49
43
68
66
61
67
61
63
61
125 59
139 59
175
59
218 63
245 63
310 63
367 63
398 68
399 68
Output kW
Motor type
Product code
1000 r/min = 6 poles
18.5
M3AA 180MLB 6 3GAA183420-��K
37
M3AA 225SMB 6 3GAA223220-��K
45
M3AA 250SMB 6 3GAA253220-��K
55
M3AA 250SMC 6 3GAA253230-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
400 V 50 Hz 980 91.7 92.5 92.0 985 93.3 93.8 93.5 991 93.7 94.1 93.6 989 94.1 94.8 94.6
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.75 38.8 6.4 180 2.1 3.1 0.22
0.80 71.5 7.0 359 2.7 3.0 0.813
0.81 85.5 7.6 434 2.9 3.3 1.5
0.80 105 7.1 531 3.0 3.1 1.49
Weight kg
Sound
pressure
Level LPA dB
168 65 307 68 389 68 390 68
ABB Motors and Generators | 9AKK105944 EN 02-2020
119
Technical data, 460V 60Hz
IE3 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
3600 r/min = 2 poles
0.75
M3AA 80MB 2 3GAA081320-��K
1.1
M3AA 80MC 2 3GAA081330-��K
1.5
M3AA 90LB 2 3GAA091520-��K
2.2
M3AA 90LC 2 3GAA091530-��K
3
M3AA 100LC 2 3GAA101530-��K
4
M3AA 112MB 2 3GAA111320-��K
5.5
M3AA 132SB 2 3GAA131120-��K
7.5
M3AA 132SC 2 3GAA131130-��K
11
M3AA 160MLA 2 3GAA161410-��K
15
M3AA 160MLB 2 3GAA161420-��K
18.5
M3AA 160MLC 2 3GAA161430-��K
22
M3AA 180MLA 2 3GAA181410-��K
30
M3AA 200MLA 2 3GAA201410-��K
37
M3AA 200MLB 2 3GAA201420-��K
45
M3AA 225SMA 2 3GAA221210-��K
55
M3AA 250SMA 2 3GAA251210-��K
90
M3AA 280SMB 2 3GAA281220-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
3502 3500 3522 3517 3512 3500 3519 3524 3549 3554 3555 3560 3562 3564 3570 3569 3573
460 V 60 Hz 77.0 75.1 84.0 83.0 85.5 85.3 86.5 87.1 88.5 88.7 88.5 88.9 89.5 89.4 90.2 90.7 91.0 91.1 91.0 90.4 91.7 91.9 91.7 91.7 92.4 92.1 93.0 92.8 93.6 93.1 93.6 93.1 95.0 95.0
69.9 80.2 84.0 85.8 87.2 87.9 88.7 90.0 89.9 89.6 90.7 90.4 90.5 91.2 91.5 91.6 94.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.72 1.56 8.9 2
4.3 5.2 0.0008
0.78 2
9.9 3
4.4 5.3 0.001
0.88 2.4 9.6 4
2.5 4.0 0.0027
0.88 3.5 9.9 5.9
3.2 4.2 0.0032
0.89 4.7 9.9 8.1
3.5 4.6 0.0057
0.90 6.2 10.0 10.9 3.6 4.8 0.0104
0.90 8.4 9.1 14.9 2.5 3.9 0.0154
0.90 11.4 9.6 20.3 3.1 4.5 0.0173
0.91 16.6 8.7 29.5 2.7 3.9 0.057
0.89 23.2 8.5 40.3 3.8 4.8 0.063
0.89 28.4 10.5 49.7 3.8 4.7 0.076
0.89 33 9.2 59.0 4.1 4.7 0.11
0.89 45.8 8.7 80.4 2.8 3.4 0.178
0.88 56.7 9.2 99.1 3.1 3.7 0.196
0.89 67.4 7.8 120 3.3 3.7 0.296
0.90 82.7 7.9 147 2.3 3.3 0.426
0.90 132 9.5 241 2.8 3.7 0.644
Weight kg
Sound
pressure
Level LPA dB
9.5
61
10.5 60
17
65
20
65
28
65
38
71
58
74
63
73
106 75
123
74
137
75
176
77
225 76
241 76
326 79
351 81
420 85
Output kW
Motor type
Product code
3600 r/min = 2 poles
22
M3AA 160MLD 2 3GAA161440-��K
30
M3AA 180MLB 2 3GAA181420-��K
37
M3AA 180MLC 2 3GAA181430-��K
45
M3AA 200MLC 2 3GAA201430-��K
55
M3AA 225SMB 2 3GAA221220-��K
75
M3AA 225SMC 2 3GAA221230-��K
75
M3AA 250SMB 2 3GAA251220-��K
90
M3AA 250SMC 2 3GAA251230-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
3552 3563 3560 3562 3571 3571 3575 3573
460 V 60 Hz 92.9 93.2 93.3 93.5 93.9 94.2 94.4 94.8 94.4 94.3 94.9 94.8 94.9 94.9 95.0 95.0
92.5 92.9 93.6 94.3 93.2 93.9 94.1 94.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.90 32.9 9.7 59.2 3.5 4.2 0.071
0.88 45.7 10.0 80.4 3.3 4.3 0.104
0.88 56.1 10.0 99.3 3.4 4.2 0.115
0.89 67.2 9.1 121 3.1 3.7 0.214
0.89 82.1 8.5 147 3.0 3.2 0.274
0.89 111 9.3 201 3.4 3.4 0.329
0.90 110 9.0 200 3.0 3.6 0.644
0.90 132 9.5 241 2.8 3.7 0.644
Weight kg
Sound
pressure
Level LPA dB
131
78
162
78
176
78
250 81
288 83
328 83
405 85
414 85
120
9AKK105944 EN 02-2020 | ABB Motors and Generators
Technical data, 460V 60Hz
IE3 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1800 r/min = 4 poles
0.75
M3AA 80ME 4 3GAA082350-��K
1.1
M3AA 90LC 4 3GAA092530-��K
1.5
M3AA 90LD 4 3GAA092540-��K
2.2
M3AA 100LE 4 3GAA102550-��K
3
M3AA 100LF 4 3GAA102560-��K
4
M3AA 112MB 4 3GAA112320-��K
5.5
M3AA 132MB 4 3GAA132320-��K
7.5
M3AA 132MC 4 3GAA132330-��K
11
M3AA 160MLA 4 3GAA162410-��K
15
M3AA 160MLB 4 3GAA162420-��K
18.5
M3AA 180MLA 4 3GAA182410-��K
22
M3AA 180MLB 4 3GAA182420-��K
30
M3AA 200MLA 4 3GAA202410-��K
37
M3AA 225SMA 4 3GAA222210-��K
45
M3AA 225SMB 4 3GAA222220-��K
55
M3AA 250SMA 4 3GAA252210-��K
75
M3AA 280SMA 4 3GAA282210-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1748 1749 1748 1760 1759 1760 1769 1766 1780 1777 1783 1783 1783 1783 1784 1787 1784
460 V 60 Hz 85.5 84.4 86.5 85.4 86.5 85.1 89.5 89.2 89.5 89.3 89.5 89.4 91.7 91.7 91.7 91.6 92.4 92.2 93.0 92.6 93.6 93.7 93.8 94.2 94.1 94.0 94.5 94.7 95.0 94.9 95.7 95.8 95.4 95.5
81.6 82.5 82.0 87.4 87.4 88.0 90.5 90.8 90.9 91.2 93.1 93.7 93.0 94.1 95.0 95.2 94.8
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.74 1.48 9.5 4
3.8 4.5 0.0027
0.77 2
8.4 6
3.7 4.6 0.0055
0.75 2.9 9.5 8.1
4.0 5.0 0.0055
0.81 3.8 10.2 11.9 3.3 4.7 0.0144
0.81 5.2 10.4 16.3 3.8 4.9 0.0144
0.74 7.6 8.8 21.7 3.8 4.4 0.0176
0.75 10 8.0 29.7 3.0 4.5 0.0295
0.79 13 8.7 40.5 2.6 3.9 0.0414
0.80 18.9 8.7 59.1 3.4 3.7 0.11
0.79 25.7 8.9 80.6 3.3 4.1 0.135
0.82 30.3 8.4 99.0 3.1 3.5 0.219
0.82 35.8 9.3 117
3.0 3.4 0.217
0.83 48.2 8.5 161 2.8 3.9 0.385
0.83 59.3 8.8 198 3.6 3.5 0.427
0.83 71.8 8.8 241 2.9 4.7 0.525
0.84 85.8 9.1 293 3.3 3.7 0.933
0.82 120 9.1 401 4.0 4.3 0.941
Weight kg
Sound
pressure
Level LPA dB
13.5 57
19
56
19
57
36
57
36
57
44
62
68
73
68
69
126 68
140 67
177
68
176
66
246 69
315 65
316
72
376 71
409 77
Output kW
Motor type
Product code
1800 r/min = 4 poles
18.5
M3AA 160MLC 4 3GAA162430-��K
30
M3AA 180MLC 4 3GAA182430-��K
37
M3AA 200MLB 4 3GAA202420-��K
55
M3AA 225SMC 4 3GAA222230-��K
75
M3AA 250SMB 4 3GAA252220-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1777 1780 1783 1782 1784
460 V 60 Hz 92.8 93.0 94.3 94.5 94.5 94.9 94.8 95.0 95.4 95.4
92.0 93.9 94.4 94.3 94.6
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.80 31.2 9.2 99.4 3.3 3.9 0.124
0.81 49 8.5 161 2.9 3.7 0.191
0.82 59.9 8.6 198 3.1 3.3 0.362
0.84 86.7 8.7 295 3.4 3.6 0.536
0.84 117 9.1 401 3.6 4.0 0.941
Weight kg
Sound
pressure
Level LPA dB
135 71
176
65
244 68
318 75
389 77
ABB Motors and Generators | 9AKK105944 EN 02-2020
121
Technical data, 460V 60Hz
IE3 Process performance aluminum motors
IP 55 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30-1; 2014
Output kW
Motor type
Product code
1200 r/min = 6 poles
0.75
M3AA 90LD 6 3GAA093540-��K
1.1
M3AA 100LE 6 3GAA103550-��K
2.2
M3AA 112MC 6 3GAA113330-��K
3
M3AA 132MC 6 3GAA133330-��K
4
M3AA 132MD 6 3GAA133340-��K
5.5
M3AA 132ME 6 3GAA133350-��K
7.5
M3AA 160MLA 6 3GAA163410-��K
11
M3AA 160MLB 6 3GAA163420-��K
15
M3AA 180MLA 6 3GAA183410-��K
18.5
M3AA 200MLA 6 3GAA203410-��K
22
M3AA 200MLB 6 3GAA203420-��K
30
M3AA 225SMA 6 3GAA223210-��K
37
M3AA 250SMA 6 3GAA253210-��K
45
M3AA 280SMA 6 3GAA283210-��K
55
M3AA 280SMB 6 3GAA283220-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1148 1168 1172 1181 1176 1177 1182 1183 1189 1191 1191 1191 1192 1192 1191
460 V 60 Hz 82.5 81.9 87.5 87.5 89.5 89.6 89.5 89.4 89.5 89.9 91.0 91.3 91.4 91.5 91.7 91.8 92.3 92.0 93.3 93.2 93.8 93.8 94.2 94.3 94.5 94.7 94.5 94.5 94.5 94.7
79.6 85.8 88.4 88.1 88.9 90.4 90.3 90.5 90.5 92.1 92.8 93.6 94.1 93.6 94.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
CENELEC-design
0.73 1.56 5.1 6.2
2.2 2.8 0.0055
0.66 2.3 6.3 9
2.4 3.5 0.0138
0.66 4.6 7.3 17.9 2.5 4.0 0.0187
0.67 6.3 7.0 24.2 2.2 3.5 0.0402
0.69 8
6.2 32.4 2.0 3.0 0.0402
0.72 10.4 6.6 44.6 2.1 3.3 0.039
0.76 13.5 8.6 60.5 1.8 3.7 0.114
0.73 20.6 9.4 88.7 2.3 4.4 0.131
0.75 27.1 6.0 120 1.8 3.1 0.225
0.77 32.3 8.6 148 2.9 3.6 0.448
0.78 37.7 8.8 176 2.9 3.6 0.531
0.80 49.9 8.9 240 3.2 3.5 0.813
0.82 59.9 8.6 296 3.0 3.2 1.49
0.80 75 8.6 361 3.2 3.6 1.5
0.81 90.1 8.2 441 3.3 3.5 1.49
Weight kg
Sound
pressure
Level LPA dB
19
61
35
52
43
71
66
64
67
64
63
64
125 63
139 63
175
63
218 67
245 67
310 67
367 67
398 72
399 72
Output kW
Motor type
Product code
1200 r/min = 6 poles
18.5
M3AA 180MLB 6 3GAA183420-��K
37
M3AA 225SMB 6 3GAA223220-��K
45
M3AA 250SMB 6 3GAA253220-��K
55
M3AA 250SMC 6 3GAA253230-��K
Efficiency IEC 60034-30-1; 2014
Full Speed load r/min 100%
3/4 load 75%
1/2 load 50%
1183 1188 1192 1191
460 V 60 Hz 93.0 93.0 94.1 94.4 94.5 94.5 94.5 94.7
91.9 93.8 93.6 94.0
Current
Power
factor IN Cosj A
IS/IN
Torque
TN Nm
TI/TN
Moment of inertia J = 1/4 Tb/TN GD2kgm2
High-output design
0.73 34.2 7.4 149 2.5 3.5 0.22
0.80 61.8 8.0 297 3.0 3.3 0.813
0.80 75 8.6 361 3.2 3.6 1.5
0.81 90.1 8.2 441 3.3 3.5 1.49
Weight kg
Sound
pressure
Level LPA dB
168 69 307 72 389 72 390 72
122
9AKK105944 EN 02-2020 | ABB Motors and Generators
Variant codes
Aluminum motors
Variant codes specify additional options and features to the standard motor. The desired features are listed as three-digit variant codes in the motor order. Note also that there are variants that cannot be used together.
Most of the variant codes apply to IE2 and IE3 motors. However, confirm the availability of variants for IE3 motors with your ABB sales office before making an order. Variant codes for L generation motors on request!
Code/Variants Administration 531 Sea freight packing 533 Wooden sea freight packing Balancing 417 Vibration acc. to Grade B (IEC 60034-14). 423 Balanced without key. 424 Full-key balancing Bearings and Lubrication 036 Transport lock for bearings. 037 Roller bearing at D-end. 039 Cold-resistant grease 040 Heat-resistant grease 041 Bearings regreasable via grease nipples. 043 SPM compatible nipples for vibration measurement 057 2RS bearings at both ends. 058 Angular contact bearing at D-end, shaft force away from bearing. 059 Angular contact bearing at N-end, shaft force towards bearing. 188 63-series bearing in D-end 593 Bearings grease suitable for food and beverage industry. 796 Grease nipples JIS B 1575 PT 1/8 Type A 797 Stainless steel SPM nipples 798 Stainless steel grease nipples Brakes 213 Brake with increased degree of protection. 412 Built-in brake. Branch standard designs 071 Cooling Tower duty 079 Silumin-alloy rotor cage. 142 Manilla connection. 178 Stainless steel / acid proof bolts. 199 Extreme heavy duty design. 209 Non-standard voltage or frequency, (special winding). 217 Cast iron D-end shield (on aluminum motor). 385 Paint free motor 425 Corrosion protected stator and rotor core. 983 Shock resistant design Cooling system 053 Metal fan cover. 068 Light alloy metal fan 075 Cooling method IC418 (without fan). 183 Separate motor cooling (fan axial, N-end). 189 Separate motor cooling, IP44, 400V, 50Hz (fan axial, N-end). Documentation 141 Binding 2D main dimension drawing. Drain holes 065 Plugged existing drain holes. Earthing Bolt
= Included as standard = Available as option - = Not applicable
Frame size 63 71 80 90 100 112 132 160 180 200 225 250 280
- - - - - -
- - - - - - - - -
- - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - -- - - - - - - - - --
- - - - - - - - - - - - -- - - - - - - - - - - - - -- - - - - - - - - - - - - -- - - - - - - - - - -
- - - - - - - - - - - -
ABB Motors and Generators | 9AKK105944 EN 02-2020
123
Code/Variants
067 External earthing bolt.
Hazardous Environments 334 Ex t, Dust group III B T125C Db, IP6X (non-conductive dust) acc. IEC/
EN60079-31. 335 Ex t, Dust group III B T125C Dc, IP5X (non-conductive dust) acc. IEC/
EN60079-31. 336 Ex t, Dust group III C T125 Db, IP6X (conductive dust) acc. IEC/
EN60079-31. 337 Ex t, Dust group III C T125 Dc, IP6X (conductive dust) acc. IEC/
EN60079-31. 340 Ex t, Dust group III B T125C Dc (non-conductive dust) with manufactur-
ers declaration 456 Ex ec IIC T3 Gc acc. IEC/EN 60079-7 with certificates. 480 Ex nA II acc. to ATEX directive 2014/34/EU, temp. class T3. 804 DIP/Ex tD, IEC 61241, T125 �C, IP55 (zone 22). 805 DIP/Ex tD, IEC 61241, T125 �C, IP65 (zone 21).
Heating elements 450 Heating element, 100-120 V 451 Heating element, 200 - 240 V
Insulation system 014 Winding insulation class H. 405 Special winding insulation for frequency converter supply. 406 Winding insulation for supply > 690 <= 1000 volts
Marine 024 Fulfilling Bureau Veritas (BV) requirements, with certificate. 025 Fulfilling Det Norske Veritas (DNV) requirements, with certificate. 026 Fulfilling Lloyds Register of Shipping (LR) requirements, with certifi-
cate. 027 Fulfilling American Bureau of Shipping (ABS) requirements, with
certificate. 049 Fulfilling Germanischer Lloyd (GL) requirements, with certificate. 050 Fulfilling Registro Italiano Navale (RINA) requirements, with certificate. 051 Fulfilling Russian Maritime Register of Shipping (RS) requirements,
with certificate. 096 Fulfilling Lloyds Register of Shipping (LR) requirements, without cer-
tificate (non-essential duty only) 186 Fulfilling Det Norske Veritas (DNV) requirements, without certificate 481 Fulfilling Nippon Kaiji Kyokai (NK) requirements, with certificate. 483 Fulfilling China Classification Societies (CCS) requirements (Beijing),
with certificate. 484 Fulfilling Korea Register of Shipping (KR) requirements, with certifi-
cate. 491 Fulfilling Nippon Kaiji Kyokai (NK) requirements, without certificate. 492 Fulfilling Registro Italiano Navale (RINA) requirements, without certifi-
cate. 493 Fulfilling China Classification Societies (CCS) requirements (Beijing),
without certificate. 494 Fulfilling Korea Register of Shipping (KR) requirements, without certifi-
cate. 496 Fulfilling Bureau Veritas (BV) requirements, without certificate(non-
essential duty only) 497 Fulfilling Russian Maritime Register of Shipping (RS) requirements,
without certificate. 675 Fulfilling American Bureau of Shipping (ABS) requirements, without
certificate (non-essential duty only) 676 Fulfilling Germanischer Lloyd (GL) requirements, without certificate
(non-essential duty only)
Mounting arrangements 007 IM 3001 flange mounted, IEC flange, from IM 1001 (B5 from B3). 008 IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3). 009 IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). 047 IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5). 048 IM 3001 flange mounted, IEC flange, from IM 3601 (B5 from B14). 066 Modified for specified mounting position differing from IM B3 (1001),
IM B5 (3001), B14 (3601), IM B35 (2001), IM B34 (2101) 080 (IM 3001) Flange mounted, DIN A-flange.
= Included as standard = Available as option - = Not applicable
124
9AKK105944 EN 02-2020 | ABB Motors and Generators
Frame size 63 71 80 90 100 112 132 160 180 200 225 250 280
- - -
- - -
- - -
- - -
- - - --
- - - - - - -- - - - - - - - - -- - - - - - - - - --
- -
- - - - - - - - - - - - - - -
- - - - - - - - -
- - -
- - - - - - - - -
-
- - - - - - -
- - -
- -
-
-
- - - - - - -
-
-
- - - - - - - - - - - - - - -- - - - - --
- - - - - - - - - --
Code/Variants 090 (IM 2101) foot/flange mounted, DIN C-flange, from IM 1001 (B34 from
B3). 091 (IM 2001) foot/flange mounted, DIN A-flange, from IM 1001 (B35 from
B3). 093 IM 3601 flange mounted, IEC flange, from IM 1001 (B14 from B3). 200 Flange ring holder. 218 Flange ring FT 85. 219 Flange ring FT 100. 220 Flange ring FF 100. 223 Flange ring FF 115. 224 Flange ring FT 115. 226 Flange ring FF 130. 227 Flange ring FT 130. 229 Flange FT 130. 233 Flange ring FF 165. 234 Flange ring FT 165. 235 Flange FF 165. 236 Flange FT 165. 243 Flange ring FF 215. 244 Flange ring FT 215. 245 Flange FF 215. 253 Flange ring FF 265. 254 Flange ring FT 265. 255 Flange FF 265. 260 Flange FT 115. 313 IM 3601 flange mounted, IEC flange, from IM 2101 (B14 from B34). 314 IM 3001 flange mounted, IEC flange, from IM 2101 (B5 from B34). 317 IM 3601 flange mounted, IEC flange, from IM 2001 (B14 from B35).
Painting 114 Special paint color, standard grade
Protection 005 Protective roof. 072 Radial seal at D-end. Not possible for 2-pole , 280 and 315 frames 158 Degree of protection IP65. 211 Weather protected, IP xx W 250 Degree of protection IP66 403 Degree of protection IP56. 404 Degree of protection IP56, without fan and fan cover. 784 Gamma-seal at D-end.
Rating & instruction plates 002 Restamping voltage, frequency and output, continuous duty. 004 Additional text on std rating plate (max 12 digits on free text line). 095 Restamping output (maintained voltage, frequency), intermittent duty. 098 Stainless rating plate. 126 Tag plate 135 Mounting of additional identification plate, stainless. 138 Mounting of additional identification plate, aluminium. 139 Additional identification plate delivered loose. 159 Additional plate with text "Made in ...." 160 Additional rating plate affixed. 161 Additional rating plate delivered loose. 163 Frequency converter rating plate. Rating data according to quotation. 270 Additional rating plate with standard data, delivered loose 332 Baldor Catalogue # 333 Not for use in the USA 818 Restamping as generator
Shaft & rotor 069 Two shaft extensions according to catalog drawings. 070 Special shaft extension at D-End, standard shaft material 131 Motor delivered with half key (key not exceeding shaft diameter) 165 Shaft extension with open keyway 410 Shaft material stainless steel
= Included as standard = Available as option - = Not applicable
Frame size
63 71 80 90 100 112 132 160 180 200 225 250 280 - - - - - - - - - --
- - - - - - - - - --
- - - - - - - - -- - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - -- - - - - - -- - - - - - - - - -- - - - - - - -- - - - - - -- - - - - - - - - - -- - - - - - - - - - -- - - - - - - - - -- - - - - - - - -- - - - - - - - - -- - - - - - - - - - -- - - - - - - - - - -- - - - - - - - - - -- - - - - - - - - - -- - - - - - - - -- - - - - - - - -- - - - - - - - --
- - - - - - - - - - - --
- - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - -
ABB Motors and Generators | 9AKK105944 EN 02-2020
125
Code/Variants 591 Special shaft extension according to customer specification. 600 Special shaft extension at N-end, standard shaft material.
Standards and Regulations 010 Fulfilling CSA Safety Certificate. 011 Fulfilling CSA Energy Efficiency Verification IE3 (code 010 included). 208 Fulfilling Underwriters Laboratories (UL), listed requirements 331 IE1 motor not for sale for use in EU 540 China energy label 542 NBR design 543 Australian MEPS 544 Australian HE MEPS 545 China Compulsory Certificate (CCC) 548 Certificate of conformity according TR-CU 004/2011 for customs
union RU, KZ, BY, AM, KG. 822 WIMES 3.03i6 Compliant Design for DOL operation 823 WIMES 3.03i6 Compliant Design for VSD operation
Stator winding temperature sensors 120 KTY 84-130 (1 per phase) in stator winding. 121 Bimetal detectors, break type (NCC), (3 in series), 130 �C, in stator
winding 122 Bimetal detectors, break type (NCC), (3 in series), 150 �C, in stator
winding 123 Bimetal detectors, break type (NCC), (3 in series), 170 �C, in stator
winding 124 Bimetal detectors, break type (NCC), (3 in series), 140 �C, in stator
winding 125 Bimetal detectors, break type (NCC), (2x3 in series), 150 �C, in stator
winding 127 Bimetal detectors, break type (NCC), (3 in series, 130 �C & 3 in series,
150 �C), in stator winding 321 Bimetal detectors, closing type (NO), (3 in parallel), 130�C, in stator
winding. 322 Bimetal detectors, closing type (NO), (3 in parallel), 150�C, in stator
winding. 323 Bimetal detectors, closing type (NO), (3 in parallel), 170�C, in stator
winding. 325 Bimetal detectors, closing type (NO), (2x3 in parallel), 150�C, in stator
winding. 327 Bimetal detectors, closing type (NO), (3 in parallel, 130�C & 3 in parallel,
150�C), in stator winding. 435 PTC - thermistors (3 in series), 130 �C, in stator winding 436 PTC - thermistors (3 in series), 150 �C, in stator winding 437 PTC - thermistors (3 in series), 170 �C, in stator winding 439 PTC - thermistors (2x3 in series), 150 �C, in stator winding 440 PTC - thermistors (3 in series, 110�C & 3 in series, 130�C), in stator
winding. 441 PTC - thermistors (3 in series, 130 �C & 3 in series, 150 �C), in stator
winding 442 PTC - thermistors (3 in series, 150 �C & 3 in series, 170 �C), in stator
winding 445 Pt100 2-wire in stator winding, 1 per phase 446 Pt100 2-wire in stator winding, 2 per phase
Terminal box 015 Motor supplied in D connection. 016 9 terminals in terminal box 017 Motor supplied in Y connection. 019 Larger than standard terminal box. 021 Terminal box LHS (seen from D-end). 022 Cable entry LHS (seen from D-end). 136 Extended cable connection, standard terminal box. 137 Extended cable connection, low terminal box, "Flying leads". 180 Terminal box RHS (seen from D-end). 230 Standard metal cable gland. 375 Standard plastic cable gland 376 Two standard plastic cable glands
= Included as standard = Available as option - = Not applicable
126
9AKK105944 EN 02-2020 | ABB Motors and Generators
Frame size 63 71 80 90 100 112 132 160 180 200 225 250 280
- - - - - - - - - - --
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - -
- - - -
- - - - - - -
-
- - - - - - -
- -
- - - - - - - --
- - - - - - - --
- - - - - - - --
- - - - - - - --
- - - - - - - --
- - - - - - - - - - --
- - -
- - - - - - - - - -
- - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - -- - - - - - - - - - - - - - - -- - - - - - - --
Code/Variants 418 Separate terminal box for auxiliaries, standard material. 467 Lower than standard terminal box and rubber extended cable. Cable
length 2 m 729 Aluminum non-drilled flange for cable glands 731 Two standard metal cable glands. 739 Prepared for metric cable glands according to DIN 42925, draft aug.
1999. 740 Prepared for PG cable glands.
Testing 140 Test confirmation. 145 Type test report from a catalogue motor, 400V 50Hz. 146 Type test with report for one motor from specific delivery batch. 147 Type test with report for motor from specific delivery batch, customer
witnessed. 148 Routine test report. 153 Reduced test for classification society. 221 Type test and multi-point load test with report for one motor from
specific delivery batch. 222 Torque/speed curve, type test and multi-point load test with report
for one motor from specific delivery batch. 760 Vibration level test 762 Noise level test for one motor from specific delivery batch. 763 Noise spectrum test for one motor from specific delivery batch.
Variable speed drives 470 Prepared for hollow shaft pulse tacho (L&L equivalent). 472 1024 pulse tacho (L&L 861007455-1024). 473 2048 pulse tacho (L&L 861007455-2048). 474 Separate motor cooling (axial fan, N-end) and prepared for hollow
shaft tacho (L&L equivalent) 476 Separate motor cooling (axial fan, N-end) and 1024 pulse tacho (L&L
861007455-1024) 477 Separate motor cooling (axial fan, N-end) and 2048 pulse tacho (L&L
861007455-2048) 570 Prepared for hollow shaft pulse tacho (L&L 503). 572 1024 pulse tacho (L&L 503). 573 2048 pulse tacho (L&L 503). 574 Separate motor cooling (fan axial, N-end) and prepared for hollow
shaft tacho (L&L 503). 576 Separate motor cooling (fan axial, N-end) and 1024 pulse tacho (L&L
503). 577 Separate motor cooling (fan axial, N-end) and 2048 pulse tacho (L&L
503). 580 Separate motor cooling, IP44, 400 V, 50Hz (axial fan, N-end) and 1024
pulse tacho (L&L 503) 581 Separate motor cooling, IP44, 400V, 50Hz (fan axial, N-end) and 2048
pulse tacho (L&L 503). 588 Shaft grounding device 661 1024 Pulse tacho mounted, Hohner series 59, 11-30V 662 2048 Pulse tacho mounted, Hohner series 59, 11-30V 701 Insulated bearing at N-end. 702 Insulated bearings at both ends 704 EMC cable entry.
= Included as standard = Available as option - = Not applicable
Frame size 63 71 80 90 100 112 132 160 180 200 225 250 280
- - - - - - - - - -
- - - - - - - - - - - - - - - - - - - --
- - - - -
- - - - - - - - - - - - - -
- - - -
- - -
- - - - - - - - - - - - - - - --
- - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - -
- - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - -
- - - - - - - - - - - - - -- - - - - - - -- - - - - - - - - - - - - - - - - - -- - -
ABB Motors and Generators | 9AKK105944 EN 02-2020
127
Mechanical design
Motor frame and drain holes
Motor frame The motor frame is made of aluminum alloy. Frame sizes 63 to 180 have aluminum feet and sizes 200 to 280 have cast iron feet. The bearing end shields of sizes 63 to 132 are made of aluminum, and those of 160 to 280 are made of cast iron. Drain holes Motors that will be operated in very humid or wet environments and especially under intermittent duty should be provided with drain holes. The IM designation, such as IM 3031, determines the intended mounting arrangement for the motor. Motors are provided with closable plastic plugs in the drain holes. The plugs on delivery, when mounting the motors, ensure that the drainholes face downwards. In the case of vertical mounting, the upper plug must be hammered home completely. In very dusty environments both plugs should be hammered home. Motors are supplied with drain holes both at the D-end and N-end. When mounting arrangement differs from foot mountedIM B3, please use variant code 066 when ordering.See variant codes 065, 066 and 076 under the heading "Drain holes".
Open
Open Closed Open
128
9AKK105944 EN 02-2020 | ABB Motors and Generators
Mechanical design
Bearings
The motors are provided with bearings according to the tables below. Greater axial forces can be tolerated if the motors are provided with angular contact ball bearings.
Standard design: deep groove ball bearings
Motor size
63
71
80
90
100
1121)
1122)
132 3)
132 4)
160
180
200
225
250
280
2 pole
280
4-8 pole
1)all types except 2)112 J-gen 3)all types except 4)SM_
Foot- and flange-mounted motor
D-end 6201-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6306-2Z/C3 6306-2Z/C3 6206-2Z/C3 6208-2Z/C3 6308-2Z/C3 6309-2Z/C3 6310-2Z/C3 6312-2Z/C3 6313-2Z/C3 6315-2Z/C3 6315/C3 6316/C3
N-end 6201-2Z/C3 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6205-2Z/C3 6205-2Z/C3 6206-2Z/C3 6206-2Z/C3 6209-2Z/C3 6209-2Z/C3 6210-2Z/C3 6212-2Z/C3 6213-2Z/C3 6213/C3 6213/C3
Note that in such cases the axial force must only operate in one direction. Motor versions with roller bearings tolerate greater radial forces. Alternative design with roller bearings It is recommended to use roller bearings in belt drives for motor sizes 160 to 280. See variant code 037 under the heading "Bearings and lubrication".
Motor size 63 71 80 90 100 1121) 1122)
1)all types except 2)112 J-gen 3)all types except 4)SM_
Foot- and flange-mounted motor
D-end NU 205 NU 306 NU 306 NU 206
N-end 6201-2Z/C3 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6205-2Z/C3 6205-2Z/C3
Motor size
132 3)
132 4)
160
180
200
225
250
280
2 pole
280
4-8 pole
1)all types except 2)112 J-gen 3)all types except 4)SM_
Foot- and flange-mounted motor
D-end NU 208 NU 308 NU 309 ECP NU 310 ECP NU 312 ECP NU 313 ECP NU 315 ECP NU 315 ECP NU 316 ECP
N-end 6206-2Z/C3 6206-2Z/C3 6209-2Z/C3 6209-2Z/C3 6210-2Z/C3 6212-2Z/C3 6213-2Z/C3 6213/C3 6213/C3
Alternative design: angular contact ball bearings See variant codes 058 and 059 under the heading "Bearings and lubrication".
Motor size
63
71
80
90
100
1121)
1122)
132 3)
132 4)
160
180
200
225
250
280
2 pole
280
4-8 pole
1)all types except 2)112 J-gen 3)all types except 4)SM_
D-end
058 7205 B 7306 B 7306 B 7206 B 7208 B 7308 B 7309 BEP 7310 BEP 7312 BEP 7313 BEP 7315 BEP 7315 BEP 7316 BEP
N-end
059 7204 B 7205 B 7205 B 7205 B 7206 B 7206 B 7209 BEP 7209 BEP 7210 BEP 7212 BEP 7213 BEP 7213 BEP 7213 BEP
Transport locking Motors provided with roller bearings or angular contact ball bearings are fitted with a transport lock to prevent damage to the bearings, due to vibration, during transport. Axially locked bearings The table below shows which of the motor's bearings are axially locked in the bearing seat. In motor size 63 the locking is done by an internal
ABB Motors and Generators | 9AKK105944 EN 02-2020
129
01 Motor sizes 71 - 132. 02 Motor sizes 160 - 250.
retaining ring, in motor sizes 71 to 280 by an inner bearing cover.
Motor size 63
71-132 160-280
Foot-mounted motors
On request at D-end D-end 1)
D-end
Flange-mounted motors
Large flange Small flange
On request at On request at
D-end
D-end
D-end 1)
D-end 1)
D-end
-
1) A spring-washer at the N-end presses the rotor toward the D-end.
Bearing seals
Motor size 71 80 90 100 112 132 160 180 200 225 250
Number of poles
Standard design, axial seal
D-end N-end
Alternative design Radial seal (Din3760) Variant code 073
2-12
V-16A Labyrinth seal 17x28x7
2-12
V-20A Labyrinth seal 20x40x7
2-12
V-25A Labyrinth seal 25x42x7
2-12
V-30A Labyrinth seal 30x47x7
2-12
V-30A Labyrinth seal 30x47x7
2-12
V-40A Labyrinth seal 40x62x7
2-12
V-45A V-45A
45x65x8
2-12
V-50A V-45A
50x72x8
2-12
V-60A V-50A
60x80x8
2-12
V-65A V-60A
65x85x8
2-12
V-75A V-65A
75x95x8
__
__
01
02
130
9AKK105944 EN 02-2020 | ABB Motors and Generators
Bearing life and lubrication Bearing life The nominal life is defined as the number of hours that are attained or exceeded by 90 percent of identical bearings, in a large test series, under certain specified conditions.50 percent of the bearings attain a life of as much as5 times this figure. The life of bearings is dependent on various factors such as bearing load, motor speed, operating temperature and the purity of the grease. The permissible radial and axial loading for different motor sizes is shown in the table on the following pages. The table is valid for 50 Hz. For 60 Hz and/or some other bearing life than specified in the table the values are changed according to the table below. The table values assume the occurrence of only radial or axial forces. In the case of simultaneous radial and axial forces information can be supplied on request. It is assumed that the radial force is applied at the end of the motor shaft. Permissible force at changed bearing life or supply frequency
Bearing life in hours at
50 Hz 25 000 40 000 63 000 80 000
60 Hz 21 000 33 000 52 000 67 000
100 % of value for 25.000 hours 100 % of value for 40.000 hours 86 % of value for 40.000 hours 80 % of value for 40.000 hours
Lubrication The motors are delivered with bearing grease for use at normal temperatures in dry or humid environments. The motors are lubricated for ambient temperatures 40�C and in other temperatures above 40�C, see table next page. Motor sizes 63 to 250 are provided with shielded bearings. As an option, motor sizes 90 to 250 are provided with grease nipples for regreasing, see variant code 041 under the heading "Bearings and lubrications". Motor size 280 is provided with grease nipples for re-greasing as standard.
The lubrication interval L1, suitable for relubricated bearings, is defined as the number of operating hours after which 99 percent of the bearings are adequately lubricated. Lubrication intervals and grease quantities are specified on a plate on the motor as well as in the manual supplied with the motor. The grease lifetime L10, suitable for permanent lubricated bearings, is defined as the number of operating hours after which 90 percent of the bearings are adequately lubricated. 50 percent of the bearings achieve two times this figure. Maximum lifetime, however, should be regarded as 40,000 hours. In case of high ambient temperatures the shaft loads must be reduced compared to permissible loadings in the table, please contact ABB. Lubrication intervals ABB follows the L1-principle in defining lubrication interval. That means that 99 percent of the motors are sure to make the interval time. The lubrication intervals can also be calculated according to the L10-principle, which are normally doubled compared to L1-values. Values available from ABB at request. The table below gives lubrication intervals according to the L1-principle for different speeds. The values are valid for horizontal mounted motors (B3), with about 80�C bearing temperature and using good quality grease with lithium complex soap and with mineral or PAO-oil. For more information, see ABB's Low Voltage Motors Manual.
ABB Motors and Generators | 9AKK105944 EN 02-2020
131
Lubrication intervals for ball and roller bearings
Amount of Frame size grease g
3600 r/min 3000 r/min
Ball bearings: lubrication intervals in duty hours
280
60
2000
3500
280
70
-
-
Roller bearings: lubrication intervals in duty hours
280
60
1000
1750
280
70
-
-
1800 r/min
8000
4000
1500 r/min
10 500
5250
1000 r/min 500-750 r/min
14 000
17 000
7000
8500
Grease lifetime In vertically mounted motors, the grease lifetime is half the figures as in following table. For applications corresponding to the empty cells in the table, please contact ABB. These applications can imply reduced lifetime for bearings and winding. Motors with roller bearings (optional) have considerably shorter grease life. For continuous operation regreasing nipples should be considered.
132
9AKK105944 EN 02-2020 | ABB Motors and Generators
Grease lifetime
Ambient temperature and rated output
25 �C
40 �C
50 �C
60 �C
70 �C
80 �C
Motor 63 71 80 90 100 1121) 1122) 132 3) 132 4) 160 180 200
r/min 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750 3000 1500 1000 750
Basic 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 38 000 40 000 40 000 40 000 27 000 40 000 40 000 40 000
High 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000
38 000 40 000 40 000
27 000 40 000 40 000
Basic 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 39 000 40 000 40 000 40 000 39 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 33 000 40 000 40 000 40 000 31 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 38 000 40 000 40 000 40 000 27 000 40 000 40 000 40 000
High 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 39 000 40 000 40 000 40 000 39 000 40 000 40 000 40 000 40 000 40 000 35 000 35 000 33 000 40 000 40 000 40 000 31 000 40 000 40 000 40 000 36 000 40 000 40 000
38 000 40 000 40 000
27 000 40 000 40 000
Basic 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 39 000 40 000 40 000 40 000 33 000 40 000 40 000 40 000 25 000 40 000 40 000 40 000 25 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 21 000 40 000 40 000 40 000 20 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 38 000 40 000 40 000 40 000 27 000 40 000 40 000 40 000
High 40 000 40 000 40 000 40 000 40 000 40 000 40 000 40 000 39 000 40 000 40 000 40 000 33 000 40 000 40 000 40 000 25 000 40 000 40 000 40 000 25 000 40 000 40 000 40 000 30 000
21 000 40 000 40 000 40 000 20 000 40 000 40 000 40 000 19 000 40 000 40 000
38 000 24 000 40 000
18 000 40 000 40 000
Basic 31 000 33 000 33 000 33 000 27 000 33 000 33 000 33 000 23 000 33 000 33 000 33 000 20 000 33 000 33 000 33 000 15 000 30 000 33 000 33 000 15 000 30 000 33 000 33 000 26 000 27 000 40 000 40 000 13 000 26 000 33 000 33 000 12 000 24 000 33 000 33 000 26 000 40 000 40 000 40 000 38 000 40 000 40 000 40 000 24 000 40 000 40 000 40 000
High 31 000 33 000 33 000 33 000 27 000 33 000 33 000 33 000 23 000 33 000 33 000 33 000 20 000 33 000 33 000 33 000 15 000 30 000 33 000 33 000 15 000 30 000 33 000 33 000 17 000
13 000 26 000 33 000 33 000 12 000 24 000 33 000 33 000 9000 38 000 40 000
23 000 12 000 40 000
10 000 32000 40 000
Basic 17 000 18 000 18 000 18 000 15 000 18 000 18 000 18 000 13 000 18 000 18 000 18 000 11 000 18 000 18 000 18 000 8000 17 000 18 000 18 000 8000 17 000 18 000 18 000
7000 14 000 18 000 18 000 6000 13 000 18 000 18 000 14 000 40 000 40 000 40 000 23 000 26 000 40 000 37000 14 000 40 000 40 000 40 000
High 17 000 18 000 18 000 18 000 15 000 18 000 18 000 18 000 13 000 18 000 18 000 18 000 11 000 18 000 18 000 18 000 8000 17 000 18 000 18 000 8000 17 000 18 000 18 000
7000 14 000 18 000 18 000 6000 13 000 18 000 18 000 5000 20 000 24 000
12 000 6000 24 000
5000 18 000 30 000
Basic 9000 9000 9000 9000 8000 9000 9000 9000 7000 9000 9000 9000 6000 9000 9000 9000 4000 9000 9000 9000 4000 9000 9000 9000
High 9000 9000 9000 9000 8000 9000 9000 9000 7000 9000 9000 9000 6000 9000 9000 9000 4000 9000 9000 9000 4000 9000 9000 9000
4000 4000 7000 7000 9000 9000 9000 9000 3000 3000 7000 7000 9000 9000 9000 9000 8000 2000 37000 10 000 40 000 12 000 40 000 13 000 7000 13 000 3000 29 000 12 000 21 000 8000 3000 30 000 10 000 38 000 17 000 40 000
1) all types except 2)112 J-gen 3)all types except 4)SM_
ABB Motors and Generators | 9AKK105944 EN 02-2020
133
Grease lifetime
Ambient temperature and rated output
25 �C
40 �C
50 �C
60 �C
70 �C
80 �C
Motor 225
250
r/min 3000 1500 1000 750 3000 1500 1000 750
Basic 23 000 40 000 40 000 40 000 16 000 40 000 40 000 40 000
High 23 000 40 000 40 000
16 000 40 000 40 000
Basic 23 000 40 000 40 000 40 000 16 000 40 000 40 000 40 000
High 18 000 40 000 40 000
13 000 39 000 40 000
Basic 23 000 40 000 40 000 40 000 16 000 40 000 40 000 40 000
High 10 000 23 000 40 000
7000 21 000 40 000
Basic 20 000 40 000 40 000 40 000 12 000 40 000 40 000 40 000
High 6000 12 000 40 000
4000 11 000 40 000
Basic 12 000 40 000 40 000 40 000 7000 33 000 40 000 40 000
High 3000 6000 40 000
2000 6000 25 000
Basic High 7000 1000 25 000 3000 40 000 27 000 40 000 4000 1000 19 000 3000 36 000 13 000 40 000
1) all types except 2)112 J-gen 3)all types except 4)SM_
Grease lifetime L10 in deep groove ball bearings of type 2Z in horizontally mounted motors in continu-
ous running duty.
134
9AKK105944 EN 02-2020 | ABB Motors and Generators
Mechanical design
Radial forces
Permissible loading on shaft The tables give the permissible radial force in Newtons, assuming zero axial force, ambient temperature of 25�C. Permissible loads of simultaneous radial and axial forces will be supplied on request. The bearing life, L10, is calculated according to SKF's theory on bearing life L10aah, which also takes the purity of the grease into consideration. An adequate lubrication is a necessary prerequisite for the table at right. If the radial force is applied between points X0 and Xmax, the permissible force FR can be calculated from the following formula:
X FR = FX0 - E (FX0 - F ) Xmax
Where: E: length of the shaft extension in the standard version
FR
X
F Xmax
F X0
ABB Motors and Generators | 9AKK105944 EN 02-2020
135
Permissible radial forces
Motor size 63 71 80 80 90 100 112 1121) 132 2) 132 3)
Poles 2-8 2-8 2 4-8 2-8 2-8 2-8 2-6 2-8 2-8
1) 112 J-gen 2) 62-series bearings 3)63-series bearings
Length of shaft extension E (mm) 23 30 40 40 50 60 60 60 80 80
Ball bearings Basic design with deep groove ball bearings
25000 hours
40000 hours
FX0 (N) 490 680 630 930 1010 2280 2280 1770 2120 2600
FXmax (N) 400 570 750 750 810 1800 1800 1430 1610 2100
FX0 (N) 490 680 930 930 1010 2280 2280 1560 2120 2600
FXmax (N) 400 570 750 750 810 1800 1800 1260 1610 2100
Motor size Poles
160
2
4
6
8
180
2
4
6
8
200
2
4
6
8
225
2
4
6
8
250
2
4
6
8
280
2
4
6
8
Ball bearings
Basic design with deep groove ball
Length bearings
of shaft 20 000 hrs extension
40 000 hrs
E (mm) FX0(N)
FXmax(N) FX0(N)
FXmax(N)
110
4760
3860
4100
3320
110
5180
4200
4380
3545
110
5160
4180
4360
3540
110
6280
4300
5320
4300
110
6060
4960
5280 1)
4305 1)
110
4800
3940
4020
3300
110
6280
5140
5280
4380
110
6960
5500
5880
4800
110
7800
6500
6760 2)
5640 2)
110
8400
7020
7180
5980
110
8960
7480
7600
6340
110
10480
8740
8940
7400
110
8520
7180
7360 3)
6200 3)
140
8380
6780
7200
5820
140
10 960 8860
9360
7560
140
12 100 9780
10 340 8360
140
10 480 4) 8500 4) 9080 4) 7360 4)
140
10 840 8780
9380
7600
140
12 600 10 220 10 700 8680
140
14 660 11 880 12 540 10 160
140
6780
5500
5680
4600
140
8060
6540
6640
5380
140
8980
7280
7360
5960
140
9180
7460
7460
6060
1) The maximum lifetime of the grease is 38000 h 2) The maximum lifetime of the grease is 27000 h 3) The maximum lifetime of the grease is 23000 h 4) The maximum lifetime of the grease is 16000 h
Roller bearings Alternative design with roller bearings
20 000 hrs
40 000 hrs
FX0(N) 6580 7340 7780 8860 7600 7280 8680 9440 10 360 11 560 12 480 14 100 12 320 13 380 15 860 17 220 16 220 18 020 20 240 22 680 16 280 19 480 21 920 22 240
FXmax(N) 4300 4300 4300 4300 5500 5500 5500 5500 8640 9550 9550 9550 10 380 10 250 10 250 10 250 10 900 13 800 13 800 13 800 13 200 15 780 17 760 18 020
FX0(N) 5620 6180 6500 7440 6560 6140 7280 7920 8880 9800 10 520 11 920 10 560 11 320 13 420 14 580 13 960 15 320 17 140 19 220 14 000 16 540 18 580 18 860
FXmax(N) 4300 4300 4300 4300 5500 5500 5500 5500 7400 8180 8780 9550 8900 9160 10 250 10 250 10 900 13 800 13 800 13 800 11 360 13 400 15 060 15 300
136
9AKK105944 EN 02-2020 | ABB Motors and Generators
Mechanical design
Axial forces
01 Mounting arrangement IM B3.
02 Mounting arrangement IM V1.
The following tables present permissible axial forces on the shaft in Newtons, assuming zero radial force, a 25 �C ambient temperature, and normal conditions. The values are given for a calculated bearing life of 20,000 and 40,000 hours per motor size. At 60 Hz, the values must be reduced by 10 percent, and for two-speed motors, the higher speed determines permissible axial force. Permissible loads of simultaneous radial and axial forces can be supplied on request. For axial force FAD, it is assumed that the D-bearing is locked with a locking ring.
FAZ FAD
FAD FAZ
__
__
01
02
Permissible axial forces
Motor size 63
71
80
90
100
Mounting arrangement IM B3, deep groove ball bearings
20 000 hours
40 000 hours
Poles 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8
FAD (N) 480 565 580 590 625 780 890 985 810 1015 1170 1300 885 1170 1270 1410 1620 2065 2390 2660
FAZ (N) 125 165 190 195 325 480 590 685 470 675 830 960 485 650 870 1010 1120 1565 1890 2160
FAD (N) 420 470 490 590 515 630 710 780 650 810 925 1015 720 945 1005 1110 1280 1615 1860 2065
FAZ (N) 105 115 145 205 215 330 410 480 315 470 595 675 320 425 605 710 780 1115 1360 1565
Mounting arrangement IM V1, deep groove ball bearings
20 000 hours
40 000 hours
FAD (N) 495 585 600
FAZ (N) 115 155 180
FAD (N) 440 490 550
FAZ (N) 95 105 115
640 800 925 1020 845 1075 1225 1350 945 1245 1360 1485 1710 2180 2510 2780
315 470 570 665 450 640 795 925 450 600 815 960 1060 1485 1815 2080
530 650 745 815 690 865 980 1070 775 1020 1095 1185 1370 1735 1980 2185
200 320 390 455 290 430 550 645 280 375 550 660 715 1035 1285 1485
ABB Motors and Generators | 9AKK105944 EN 02-2020
137
Permissible axial forces
Mounting arrangement IM B3, deep groove ball bearings
Motor
size
Poles
112 M, 2
MB
4
6
8
112 J- 2
gen
4
6
8
132 M, 4
MA
6
8
132 MC 6
132 MBA 4
132 S 6
8
132 SB 2
132 SBB, 2 SC
132
2
SMB, 4 SMC
132 SMD 4
132 SME 2
160
2
4
6
8
180
2
4
6
8
200
2
4
6
8
225
2
4
6
8
250
2
4
6
8
280
2
4
6
8
20 000 hours
FAD (N) 1615 2060 2385 2655 1500 1600 1720 1760 2245 2595 2875 2580 2235 2600 2885 1760 1760
FAZ (N) 1115 1560 1885 2155 1000 1100 1220 1260 1645 1980 2270 1980 1635 2000 2285 1160 1160
2210 2840
2830 2210 4160 4740 4840 5980 5480 4360 5980 6000 5000 5000 5000 5000 5000 5000 5000 5000 6000 4) 6000 6000 6000 5260 6500 7500 7740
1610 2240
2200 1610 4160 4740 4840 5980 5480 4360 5980 6620 6880 7660 8300 9880 7380 7600 10140 11 420 9020 4) 9800 11520 13 700 5260 6500 7500 7740
40 000 hours
FAD (N) 1275 1610 1860 2060 1160 2160 1380 1420 1760 2025 2240 2010 1750 2030 2245 1400 1395
FAZ (N) 775 1110 1360 1560 660 760 880 920 1160 1425 1640 1410 1150 1435 1645 800 795
1740 2205
2230 1730 3425 3920 4000 4920 4600 1) 3540 4940 5460 5000 2) 5000 5000 5000 5000 3) 5000 5000 5000 6000 4) 6000 6000 6000 4220 5160 6040 6180
1140 1605
1595 1130 3425 3920 4000 4920 4600 1) 3540 4630 5460 5700 2) 6340 6880 8160 6120 3) 6220 8420 9460 7500 4) 8040 9520 11 380 4220 5160 6040 6180
1) The maximum lifetime of the grease is 38 000 h 2) The maximum lifetime of the grease is 27 000 h 3) The maximum lifetime of the grease is 23 000 h 4) The maximum lifetime of the grease is 16 000 h
Mounting arrangement IM V1, deep groove ball bearings
20 000 hours
40 000 hours
FAD (N) 1725 2210 2540 2790 1610 2100 2430 2880 2460 2815 3130 2885 2495 2780 3100 1910 1945
FAZ (N) 1040 1460 1785 2055 1010 1430 1760 1740 1505 1850 2115 1780 1465 1885 2145 1075 1045
FAD (N) 1385 1110 2010 2195 1260 985 1885 2075 1970 2245 2490 2315 2010 2210 2460 1540 1575
FAZ (N) 700 1010 1260 1475 675 885 1135 1325 1015 1280 1470 1210 980 1315 1505 705 670
2435 3150
3195 2490 4560 5260 5400 6560 5920 5080 6000 6000 5000 5000 5000 5000 5000 5000 5000 5000 6000 4) 6000 6000 6000 6400 7920 8500 8500
1470 2035
1995 1425 3810 4310 4420 5580 5115 3860 5445 6120 6350 6950 7505 9215 6770 6795 9270 10 595 8335 4) 8820 10 275 12 645 4400 5400 6180 6435
1950 2515
2560 2005 3860 4440 4540 5460 5060 1) 4240 5600 6000 5000 2) 5000 5000 5000 5000 3) 5000 5000 5000 6000 4) 6000 6000 6000 5420 6640 7840 7980
985 1400
1355 940 3110 3490 3560 4480 4255 1) 3020 4385 4900 5230 2) 5650 6025 7435 5490 3) 5475 7490 8535 6755 4) 7120 8235 10 205 3420 4120 4640 4775
138
9AKK105944 EN 02-2020 | ABB Motors and Generators
Mechanical design
Terminal box
Sizes 63 to 180 The terminal box is made of aluminum alloy and is located on top of the stator. The lower part of the box is integrated with the stator. It is provided with two knockout openings on each side. Sizes 132 SM_ and 160 - 180 also have a third smaller opening. Cable glands are not included. Sizes 200 to 280 The terminal box and cover are made of deep drawn steel and mounted on top of the stator. The box is bolted to the stator and is not rotatable. The size of the box is the same for all frame sizes. The motors can also be provided with an extra large terminal box, standard for voltage code S and frame size 280. See variant code 019 under the heading "Terminal box". This will increase the dimension HD by 32 mm. The box is supplied with two FL 21 openings. The right opening is provided with a flange with two holes for M63 cable glands. The holes are sealed by means of plastic plugs. Cable glands are not supplied. The opening on the other side is provided with a cover flange. The box can also be provided with an FL 13 opening towards the N-end. When new motors are manufactured the terminal box can be mounted on the left or the right side. See variant codes 021 and 180 under the heading "Terminal box". In the basic design the terminal box is provided with twoFL 13 flange openings, one on each side. The opening on the right side, seen from the Dend, is supplied with a flange with two holes for M40 cable glands. On delivery the holes are sealed by means of plastic plugs. Cable glands are not supplied. The opening on the other side is provided with a cover flange.
Dimensions for terminal box
Dimensions
Motor size
HB
HD
HE
Code 019: Larger than standard terminal box
200 ML
332.5 603 240
225 SM
353 578 260.5
250 SM
376 626 283.5
Code 021: Terminal box on left-hand side seen from D end
Code 180: Terminal box on right-hand side seen from D end
200 ML
332 532 239
225 SM
354 579 260.5
250 SM
377 627 284
Code 467: Lower than standard terminal box without screw terminals and extended rubber connection cable 2 m.
160
211.5 371.5
180
226.5 406.5
200 ML
248 448
225 SM
269 494
250 SM
292 542
280
292 572
Refer to the Dimension drawings section for dimensions HB, HD and HE.
ABB Motors and Generators | 9AKK105944 EN 02-2020
139
01 Terminal board for motor sizes 63 to 80.
Connections
02 Terminal board for motor sizes 90 to 112.
03 Terminal board for motor size 132.
04 Terminal board for motor sizes 160 to 180 in G-generation.
05 Terminal board for motor sizes 160 to 200 in L-generation.
06 Terminal board for
motor sizes 200 to 280 in G-generation.
__
__
01
05
07 Terminal board for
motor sizes 225 to 280
in L-generation.
__
__
02
06
__
__
03
07
The terminal block is provided with six terminals for connecting Cu-cable. The terminals are marked in accordance with IEC 60034-8.
__ 04
140
9AKK105944 EN 02-2020 | ABB Motors and Generators
Connection openings
Motor size
63
Opening Knock-out opening
71-80 90-112 132 1) 132 2) 160-180 200-250 280
Knock-out opening Knock-out opening Knock-out opening Knock-out opening Knock-out opening 2 x FL 13 2 x FL 21
1) All types except 2) 2) SM_
Metric cable entry 1 x M16 x 1.5 1 x Pg 11 2 x ( 2 x M20 ) 2 x (M25 + M20) 2 x (M25 + M20) 2 x (M40 x M32 + M12) 2 x (2 x M40) + M16 1 x (2 x M40 + M16) 1 x (2 x M63 + M16)
Method of connection
Cable lug
Terminal bolt size
Maximum connectable Cu-cable area, mm 2
M4
2.5
Cable lug
M4
4
Screw terminal M4
6
Cable lug
M5
10
Cable lug
M6
35
Cable lug
M6
35
Cable lug
M10
70
Cable lug
M10
70
ABB Motors and Generators | 9AKK105944 EN 02-2020
141
Dimension drawings
Process performance IE2 aluminum motors
Foot-mounted motor IM1001, B3 and flange-mounted motor IM3001, B5
Motor size Poles
D
63
11
71
14
80
19
90
S 8
24
90
L2, L8, LB 2-8
24
90
LD 4-6
24
100
LB2, LC 4-8, LA8, LB8
28
100
LD 4
28
112
28
132
SB2, M4, MA4, MBA4
38
132
SC2, MC6
38
132
SM_
38
160
MLA 2-8, MLB2, MLB8
42
160
MLB 4-6, MLC 2-8, MLD 2-4 42
180
48
200
55
225
55
225
60
250
60
250
65
280
65
280
75
GA F 12.5 4 12.5 5 21.5 6 27 8 27 8 27 8 31 8 31 8 31 8 41 10 41 10 41 10 45 12 45 12 51.5 14 59 16 59 16 63 18 64 18 69 18 69 18 79.5 20
E
L max A
B
B1 C
HD K
23 217 100 80
40 169 7
30 240 112 90
45 180 7
40 265.5 125 100
50 193.5 10
50 284.5 140 125
56 217 10
50 309.5 140 125
56 217 10
50 331.5 140 125
56 217 10
60 351 160 140
63 237 12
60 373 160 140
63 237 12
60 393 190 140
70 249 12
80 447 216 140 178 89 295.5 12
80 487 216 140 178 89 295.5 12
80 550 216 140 178 89 321 12
110 584 254 210 254 108 370 15
110 681 254 210 254 108 370 15
110 726 279 241 279 121 405 15
110 821 318 267 305 133 532 18
110 850 356 286 311 149 579 18
140 880 356 286 311 149 579 18
140 884 406 406 349 168 627 22
140 884 406 406 349 168 627 22
140 884 457 457 419 190 657 24
140 884 457 457 419 190 657 24
MN
P
S
115 95 140 7
130 110 160 10
165 130 200 12
165 130 200 12
165 130 200 12
165 130 200 12
215 180 250 15
215 180 250 15
215 180 250 15
265 230 300 14.5
265 230 300 14.5
265 230 300 14.5
300 250 350 19
300 250 350 19
300 250 350 19
400 350 400 19
400 350 450 19
400 350 450 19
500 450 550 19
500 450 550 19
500 450 550 19
500 450 550 19
IMB14 (IM3601)
Motor size M
N
63
75
60
71
85
70
80
100 80
90
115
95
P
S
90
5
105 6
120 6
140 8
Motor size M
N
P
S
100
130 110 160 8
112
130 110 160 8
132
165 130 200 10
132SM_ 165 130 200 10
Tolerances A, B D
�0,8 ISO j6 � 28 mm ISO k6 < � 38 mm ISO m6 � 55 mm
Tolerances
F
ISO h9
H
-0,5
N
ISO js6
C
�0,8
The table gives the main dimension in mm. For detailed drawings please see our web pages www.abb.com/motors&generators.
142
9AKK105944 EN 02-2020 | ABB Motors and Generators
Dimension drawings
Process performance IE3 aluminum motors, J/L-generation
Foot-mounted motor IM1001, B3 and flange-mounted motor IM3001, B5
Motor size 80 80 90 90 100 100 112 112 132 132 160 160 180 200 225 225 250 250 280 280
Poles B 2, C2 E 4 L2, L8, LB2-8 LD4-6 LC4 LB2, LC6, LD 4 MB2 MB4-6 S6, M4, MA4 SB2, SC2, MA6, MC6 MLA2 MLB2, MLC2, 4-6 p
2 pole 4-6 poles 2 pole 4-6 poles 2 pole 4-6 poles
D
GA F
E
L max A
B
B1 C
HD K
19 21.5 6
40 265.5 125 100
50 193.5 10
19 21.5 6
40 293 125 100
50 193.5 10
24 27 8
50 309.5 140 125
56 217 10
24 27 8
50 331.5 140 125
56 217 10
28 31 8
60 351 160 140
63 237 12
28 31 8
60 393 160 140
63 237 12
28 31 8
60 390 190 140
70 258 12
28 31 8
60 410 190 140
70 258 12
38 41 10 80 447 216 140 178 89 295.5 12
38 41 10 80 487 216 140 178 89 295.5 12
42 45 12 110 584 254 210 254 108 370 15
42 45 12 110 681 254 210 254 108 370 15
48 51.5 14 110 681 279 241 279 121 390 15
55 59 16 110 726 318 267 305 133 425 18
55 59 16 110 821 356 286 311 149 531 18
60 64 18 140 851 356 286 311 149 531 18
60 64 18 140 880 406 311 349 168 578 22
65 69 18 140 880 406 311 349 168 578 22
65 69 18 140 884 457 457 419 190 631 24
75 79.5 20 140 884 457 457 419 190 631 24
MN
P
S
165 130 200 12
165 130 200 12
165 130 200 12
165 130 200 12
215 180 250 15
215 180 250 15
215 180 250 15
215 180 250 15
265 230 300 14.5
265 230 300 14.5
300 250 350 19
300 250 350 19
300 250 350 19
400 350 400 19
400 350 450 19
400 350 450 19
500 450 550 19
500 450 550 19
500 450 550 19
500 450 550 19
IMB14 (IM3601)
Motor size M
N
P
S
80
100 80
120 6
90
115
95
140 8
100
130 110 160 8
Motor size M
N
P
S
112
130 110 160 8
132
165 130 200 10
Tolerances A, B D
�0,8 ISO j6 � 28 mm ISO k6 < � 38 mm ISO m6 � 55 mm
Tolerances
F
ISO h9
H
-0,5
N
ISO js6
C
�0,8
The table gives the main dimension in mm. For detailed drawings please see our web pages www.abb.com/motors&generators.
ABB Motors and Generators | 9AKK105944 EN 02-2020
143
Dimension drawings
Process performance IE3 aluminum motors, K-generation
Foot-mounted motor IM1001, B3 and flange-mounted motor IM3001, B5
Motor size 80 80 90 100 112 132 160 180 200 225 225 250 250
Poles MB2, MC2 ME4 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2 4-6 2 4-6
D
GA F
19 21.5 6
19 21.5 6
24 27 8
28 31 8
28 31 8
38 41 10
42 45 12
48 51.5 14
55 59 16
55 59 16
60 64 18
60 64 18
65 69 18
E
L max A
B
B1 C
HD K
40 265.5 125 100
50 193.5 10
40 293.5 125 100
50 193.5 10
50 331.5 140 125
56 217 10
60 432 160 140
63 237 12
60 431 190 140
70 260 12
80 487 216 140 178 89 298 12
110 681 254 210 254 108 370 15
110 726 279 241 279 121 405 15
110 821 318 267 305 133 532 18
110 850 356 286 311 149 553 18
140 880 356 286 311 149 553 18
140 884 406 311 349 168 601 22
140 884 406 311 349 168 601 22
M
N
P
S
165 130 200 12
165 130 200 12
165 130 200 12
215 180 250 15
215 180 250 15
265 230 300 14.5
300 250 350 19
300 250 350 19
400 350 400 19
400 350 450 19
400 350 450 19
500 450 550 19
500 450 550 19
IMB14 (IM3601)
Motor size M
N
P
S
80
100 80
120 6
90
115
95
140 8
100
130 110 160 8
Motor size M
N
P
S
112
130 110 160 8
132
165 130 200 10
Tolerances A, B D
�0,8 ISO j6 � 28 mm ISO k6 < � 38 mm ISO m6 � 55 mm
Tolerances
F
ISO h9
H
-0,5
N
ISO js6
C
�0,8
The table gives the main dimension in mm. For detailed drawings please see our web pages www.abb.com/motors&generators.
144
9AKK105944 EN 02-2020 | ABB Motors and Generators
Accessories
Slide rails for motor sizes 160 to 280
E H
B N
1 M
Ymax.
L
Xmax. 3
5
F
O
D C
2
4
G A
1 Motor | 2 Rail | 3 Movable adjusting bolt | 4 Fixing bolt, motor | 5 Plate
Motor size Type
1)
Product code 3GZV103001-
160-180 200-225 250-280
TT180/12 -14 TT225/16 -15 TT280/20 -16
1) Smaller sizes on request.
Weight A B C D E F G H L M N O Xmax Ymax (kg)
75 42 700 630 57 17 26 M12 120 M12 50 -
520 580 12.0
82 50 864 800 68 17 27 M16 140 M16 65 17 670 740 20.4
116 70 1072 1000 90 20 27 M18 150 M20 80 20 870 940 43.0
Each set includes two complete slide rails including screw for mounting the motor on the rails. Screws for mounting the rails on the foundation are not included. Slide rails are supplied with unmachined lower surfaces and should, prior to tightenng down, be supported in a suitable manner.
ABB Motors and Generators | 9AKK105944 EN 02-2020
145
Motors in brief
Aluminum motors, sizes 63 - 132
Motor size Stator and end shields
Feet
M3AA Material Paint colour shade Corrosion class
Bearings
D-end
N-end Axially-locked bearings Inner bearing cover
Bearing seal
D-end
N-end
Lubrication
Measuring nipples for condition monitoring of the bearings
Rating plate
Material
Terminal box
Material
Cover screws material
Connections
Openings
Fan Fan cover
Stator winding
Rotor winding Balancing Key ways Drain holes
Terminals Cable glands Material Material Paint colour shade Corrosion class Material Insulation Winding protection Material
External earthing bolt Enclosure Cooling method
63
71
80
90
100
112
132
Die-cast aluminum alloy
Munsell blue 8B 4.5/3.25
C3 medium according IEO/EN 12944-5
Separate
Integrated aluminum feet
bolt on feet
6201-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6306-2Z/C3 6306-2Z/C3 6208-2Z/C3 6308-2Z/C3 (SM)
6201-2Z/C3 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6205-2Z/C3 6206-2Z/C3
ND-end re- Locked at D-end taining ring
V-ring
Labyrinth seal
Permanent grease lubrication. Grease temperature range -40�C to +160�C
Not included
Aluminum
Die-cast aluminum alloy, integrated to stator
Zinc-electroplated steel
1xM16
2x(M20 + M20)
2x(M20 + M20)
2x(M20+M25)
6 terminals for connection with cable lugs (not included)
Optional
Glass-fiber reinforced polypropylene
Polypropylene
Munsell blue 8B 4.5/3.25
C3 medium according IEO/EN 12944-5
Copper
Insulation class F
Optional
Die-cast aluminum
Half key balancing
Closed key way
Without
Drain holes with closable plastic plugs, open on delivery
drain holes
As option
IP 55
IC 411
2x(M20+M25) 1) 2x(M40+M32+M12) 2)
1) S, SB, M, MA 2) SC, MC, SMA-SME
146
9AKK105944 EN 02-2020 | ABB Motors and Generators
Motors in brief
Aluminum motors, sizes 160 - 280
Motor size
M3AA
Stator and end shields Material
Paint colour shade
Corrosion class
Feet
Bearings
D-end
N-end
Axially-locked bearings Inner bearing cover
Bearing seal
D-end
N-end
Lubrication
Measuring nipples for condition monitoring of the bearings
Rating plate
Material
Terminal box
Material
Connections
Cover screws material Openings
Fan Fan cover
Stator winding
Rotor winding Balancing Key ways Drain holes External earthing bolt Enclosure Cooling method
Terminals Cable glands Material Material Paint colour shade Corrosion class Material Insulation Winding protection Material
160
180
200
225
Die-cast aluminum alloy
Extruded aluminum alloy
Munsell blue 8B 4.5/3.25
C3 medium according IEO/EN 12944-5
Separate aluminum feet
Separate cast iron feet
6309-2Z/C3
6310-2Z/C3
6312-2Z/C3
6313-2Z/C3
6209-2Z/C3
6209-2Z/C3
6210-2Z/C3
6212-2Z/C3
Locked at D-end
Axial seal
Axial seal
Permanently lubricated shielded bearings
Not included
250
6315-2Z/C3 6213-2Z/C3
Aluminum
Die-cast aluminum alloy, integrated Deep-drawn steel sheet, bolted to stator to stator Zinc-electroplated steel
(2xM40+M16+(2xM40)
2xFL13, 2xM40 + 1xM16
Knock-out
6 terminals for connection with cable lugs (not included)
Optional
Glass-fiber reinforced polypropylene
Steel
Munsell blue 8B 4.5/3.25
C3 medium according IEO/EN 12944-5
Copper
Insulation class F
3 PTC thermistors, 150 �C
Die-cast aluminum
Half key balancing
Closed key way
Drain holes with closable plastic plugs, open on delivery
As option
IP 55
IC411
280 6316/C3 6213/C3 Regreasable
2xFL21
ABB Motors and Generators | 9AKK105944 EN 02-2020
147
Total product offering
Motors, generators and mechanical power transmission products with a complete portfolio of services
IEC motors �� Low voltage motors �� High voltage induction and synchronous mo-
tors �� Marine motors �� Motors for explosive atmospheres �� Motors for food and beverage �� Motors for variable speed drives �� Permanent magnet motors �� Synchronous reluctance motors �� Traction motors NEMA motors �� Low voltage motors �� High voltage induction and synchronous mo-
tors �� Marine motors �� Motors for explosive atmospheres �� Motors for variable speed drives �� Permanent magnet motors �� Servomotors �� Washdown motors
Generators �� Generators for wind turbines �� Generators for diesel and gas engine
power plants �� Generators for steam and gas turbine
power plants �� Generators for marine applications �� Generators for industrial applications �� Generators for traction applications �� Synchronous condensers for reactive power
compensation Mechanical power transmission components, bearings, gearings �� Mounted bearings �� Enclosed gearing �� Mechanical drive components �� Couplings �� Sheaves and bushings �� Conveyor components �� Geared motor units Life cycle services
148
9AKK105944 EN 02-2020 | ABB Motors and Generators
ABB's portfolio of drives
Optimal solution for you
Being able to rely on the continuous high performance and efficiency of your operations is something you want to take for granted. ABB variablefrequency drives are made with all this in mind, established upon more than 40 years of experience and backed by a broad range of life cycle services. ABB drives help you to optimize your processes and systems with state-of-the-art motor control technology, resulting in increased energy efficiency, better product quality, and reduced operating costs with higher output, less downtime, and reduced need for maintenance. All ABB drives are designed for easy selection, ordering, installation and use, and they offer integrated safety features, giving you more time to focus on what matters for you and your business.
Our portfolio offers low-voltage AC and DC drives, medium-voltage AC drives, and motion control drives spanning the fractional-kilowatt to multimegawatt power level. There is a drive available for essentially every industry and application and for all types of motors, in environments ranging from water utility facilities to clean electrical rooms, and to harsh coal mines and windy offshore platforms to food and beverage production. This wide product range allows you to select the best-fitting drive solution, providing maximum reliability and efficiency for every need.
ABB Motors and Generators | 9AKK105944 EN 02-2020
149
Contact us
For more information and contact details: www.abb.com/motors&generators
� Copyright 2020 ABB. All rights reserved. Specifications subject to change without notice.
9AKK105944 EN 02-2020