Roofing-Underlayment-Code-GAF-Roof Underlayments-and-AsphaltApplied-Underlayments-Florida-Approval FL10626R19
12/15/2020

Florida Building Code Online

BCIS Home Log In User Registration

Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search

Product Approval
USER: Public User

Product Approval Menu > Product or Application Search > Application List > Application Detail

FL # Application Type Code Version Application Status

FL10626-R19 Revision 2020 Approved

Comments Archived

Product Manufacturer Address/Phone/Email

GAF
1 Campus Drive Parisppany, NJ 07054 (800) 766-3411 mstieh@gaf.com

Authorized Signature

Robert Nieminen lreith@nemoetc.com

Technical Representative Address/Phone/Email

William Broussard
1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 TechnicalQuestionsGAF@gaf.com

Quality Assurance Representative Address/Phone/Email

Category Subcategory

Roofing Underlayments

Compliance Method

Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received

Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report

Florida License

PE-59166

Quality Assurance Entity

UL LLC

Quality Assurance Contract Expiration Date

12/17/2021

Validated By

John W. Knezevich, PE

Validation Checklist - Hardcopy Received

Certificate of Independence

FL10626_R19_COI_2020_01_COI_NIEMINEN.pdf

Referenced Standard and Year (of Standard)

Standard ASTM D1970 ASTM D4533 ASTM D4798 ASTM D4869 ASTM D5035 ASTM D6164 ASTM D6757 FM 4474 FRSA/TRI, 6th Edition

Year 2015 2015 2011 2016 2011 2011 2016 2011 2018

https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtBNbEY5V%2boQY9nVE2RUHV0uwgULxCexQ2c%2bVr8U8ir4w%3d%3d

1/2

12/15/2020

Equivalence of Product Standards Certified By
Sections from the Code

Florida Building Code Online

Product Approval Method

Method 1 Option D

Date Submitted Date Validated Date Pending FBC Approval Date Approved

10/22/2020 10/23/2020 10/30/2020 12/15/2020

Summary of Products

FL #

Model, Number or Name

10626.1

GAF Roof Underlayments

Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-442.5 Other: 1.) The design pressure noted in this application relates to one particular underlayment system. Refer to ER Section 5.8.3 for details. 2.) Refer to ER Section 5 for other Limits of Use.

Description
Roofing Underlayments for use in sloped roof systems
Installation Instructions FL10626_R19_II_2020_10_19_FINAL_ER_GAF_UNDERLAYMENTS_FL10626R19.pdf Verified By: Robert Niemien 59166 Created by Independent Third Party: Yes Evaluation Reports FL10626_R19_AE_2020_10_19_FINAL_ER_GAF_UNDERLAYMENTS_FL10626R19.pdf Created by Independent Third Party: Yes

Back Next

Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:

https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtBNbEY5V%2boQY9nVE2RUHV0uwgULxCexQ2c%2bVr8U8ir4w%3d%3d

2/2

ENGINEER
GAF 1Campus Drive Parsippany, NJ 07054 (800) 766-3411

EVALUATE

TEST

EVALUATION REPORT

NEMO|etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245
CONSULT
Evaluation Report 01506.04.08-R19 FL10626-R19
Date of Issuance: 04/25/2008 Revision 19: 10/19/2020

SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: GAF Roof Underlayments

LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO|etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official.

This Evaluation Report consists of pages 1 through 8.

Prepared by:

Robert J.M. Nieminen, P.E.

The facsimile seal appearing was authorized by Robert

Florida Registration No. 59166, Florida DCA ANE1983

Nieminen, P.E. on 10/19/2020. This does not serve as an electronically signed document.

CERTIFICATION OF INDEPENDENCE:

1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or

distributing products it evaluates.

2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.

3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for

which the evaluation reports are being issued.

4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the

product.

5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any

project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained

specifically for that purpose.

©2019 NEMO ETC, LLC

NEMO|etc.

ROOFING COMPONENT EVALUATION:

1. SCOPE:

Product Category:

Roofing

Sub-Category:

Underlayment

Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following

Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth

herein.

2. STANDARDS:

Section 1504.3.1 1507.1.1, 1507.2.4, 1507.2.9.2 / R905.1.1, R905.2.8.2 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(5) / R905.1.1.1(5) 1507.1.1 / R905.1.1 1507.3.3, R905.3.3 1507.11.2 TAS 110

Property Wind resistance Material standard
Tear Strength
Tensile strength
Liquid water transmission Material standard Material standard Material standard Accelerated Weathering

Standard FM 4474 ASTM D1970
ASTM D4533
ASTM D5035
ASTM D4869 ASTM D6757 FRSA/TRI, Sixth Edition ASTM D6164 ASTM D4798

3. REFERENCES:
Entity ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) Intertek (TST 1558) NEMO (TST 6049) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) UL (TST 1740) UL (TST 1740)

Examination ASTM D1623 & FRSA/TRI (Slippage) ASTM D6164 (GA) ASTM D6164 (GA) ASTM D1970 (GA) ASTM D1970 (GA) ASTM D1970 (GA) ASTM D4869 (Dadra, India) Physical Properties (ON) ASTM D1970 (IN) ASTM D226 (OK) ASTM D4798 (NC) Wind Uplift Wind Uplift Wind Uplift ASTM D4533 (various) ASTM D1970 (AL) ASTM D4533 (LA) ASTM D4533 (Dadra, India) ASTM D4533 (Dadra, India) ASTM D4533, D5035 (VA) ASTM D4533 (Umerkui Kilvani, India) ASTM D4533 (Parzai, India) ASTM D1970 (AR) ASTM D5035 (various) ASTM D6757 (TX) ASTM D6757 (NC)

Reference G34150.08.11 G40630.01.14-2B G46160.09.14-3A GAF-SC13285.03.17-3 GAF-SC13285.03.17-4 GAF-SC13285.03.17-1 F8549.02-106-18 4q-GAF-19-SSMBB-03.A GAF-324-02-01 GAF-339-02-01 GAF-349-02-01 GAF-434-02-01 GAF-434-02-03 GAF-434-02-04 GAF-818-02-01 MSA-047-02-01 GAF-826-02-01 GAF-847-02-01 GAF-914-02-01 376T0012 376T0018 376T0018 376T0032 376T0103 02NK22569 10NK11990

Year 2011 2015
2015
2011
2016 2016 2018 2011 2011
Date 11/14/2011 01/07/2014 09/09/2014 03/01/2017 03/01/2017 03/08/2017 11/08/2016 05/13/2019 11/30/2011 03/13/2012 07/03/2012 09/16/2013 09/16/2013 09/16/2013 12/05/2017 04/11/2018 06/4/2018 06/4/2018 04/10/2019 07/15/2019 07/31/2019 07/31/2019 10/22/2019 09/11/2020 06/04/2002 05/18/2011

NEMO ETC, LLC
Certificate of Authorization #32455

7TH EDITION (2020) FBC NON-HVHZ EVALUATION GAF Roof Underlayments

Evaluation Report 01506.04.08-R19 FL10626-R19
Revision 19: 10/19/2020 Page 2 of 8

Entity NEMO ETC UL, LLC (QUA 9625) UL, LLC (QUA 9625) UL, LLC (QUA 9625)

Examination Traceability Quality Control Quality Control Quality Control

Reference FBC Cross-Listing Service Confirmation Service Confirmation (AL) Florida BCIS

NEMO|etc.
Date 04/22/2020 09/29/2020 05/04/2020 Current

4. PRODUCT DESCRIPTION:

Product

4.1

LibertyTM SBS Self-Adhering Base/Ply Sheet

4.2 StormGuard® Film Surfaced Leak Barrier

4.3

WeatherWatch® Mineral Surfaced Leak Barrier

4.4

Deck-ArmorTM Premium Breathable Roof Deck Protection

4.5

FeltBuster® High-Traction Synthetic Roofing Felt

4.6 Shingle-Mate® Roof Deck Protection

4.7 StormSafeTM Anchor Sheet

4.8 Tiger PawTM Roof Deck Protection

4.9

RoofProTM SBS-Modified All-Purpose Underlayment

4.10

VersaShield® Fire-Resistant Roof Deck Protection

4.11 Ruberoid® Mop Granule

4.12 Ruberoid® Mop Granule FR

Material Standard
ASTM D1970
ASTM D1970
ASTM D1970
1507.1.1.1(2&3, Exception) / R905.1.1.1(2&3, Exception) 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) ASTM D226, Type II (Table 1) 1507.1.1.1(2&3, Exception) / R905.1.1.1(2&3, Exception) 1507.1.1.1(2&3, Exception) / R905.1.1.1(2&3, Exception)
AC165
ASTM D6757
ASTM D6164 FRSA/TRI 09-18
ASTM D6164 FRSA/TRI 09-18

Plant(s)
Savannah, GA Mt. Vernon, IN Savannah, GA Arkadelphia, AR Mt. Vernon, IN Savannah, GA Tuscaloosa, AL
Dadra, India
Dadra, India Richmond, VA Spartanburg, SC
Pryor, OK
North Bay, ON
Dadra, India Parzai, India Umerkui Kilvani, India
Fontana, CA
Conover, NC
Savannah, GA
Savannah, GA

5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation.

NEMO ETC, LLC
Certificate of Authorization #32455

7TH EDITION (2020) FBC NON-HVHZ EVALUATION GAF Roof Underlayments

Evaluation Report 01506.04.08-R19 FL10626-R19
Revision 19: 10/19/2020 Page 3 of 8

NEMO|etc.
5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:

Underlayment
LibertyTM SBS Self-Adhering Base/Ply Sheet
StormGuard® Film Surfaced Leak Barrier
WeatherWatch® Mineral Surfaced Leak Barrier
Deck-ArmorTM Premium Breathable Roof Deck Protection FeltBuster® High-Traction Synthetic Roofing Felt Shingle-Mate® Roof Deck Protection Tiger PawTM Roof Deck Protection RoofProTM SBS-Modified AllPurpose Underlayment VersaShield® Fire-Resistant Roof Deck Protection
Ruberoid® Mop Granule
Ruberoid® Mop Granule FR

Asphalt Shingles
(1507.2)
Yes
Yes
Yes Yes Yes Yes Yes Yes Yes
No
No

TABLE 1: ROOF COVER OPTIONS

Clay and Concrete Tile
(1507.3)

Mechanical Adhesive-

Attach

Set

Metal

Panels
(1507.4)

Shingles
(1507.5)

No

No

No

No

No

No

Yes

Yes

No

No

No

No

No

No

Yes

Yes

No

No

No

No

No

No

No

No

No

No

Yes

Yes

No

No

No

No

No

No

No

No

Yes

Yes

(Cap Sheet in 2-ply system)

(Cap Sheet in 2-ply system)
See 5.6.1

No

No

Yes
(Cap Sheet in 2-ply system)

Yes
(Cap Sheet in 2-ply system)
See 5.6.1

No

No

Slate or Slate-Type Shingles
(1507.7)
No
Yes
No
Yes No No Yes Yes No
No
No

Wood

Shingles
(1507.8)
Yes
(joint strips, 1507.1.1.3 / R905.1.1.3)
Yes
(joint strips, 1507.1.1.3 / R905.1.1.3)
Yes
(joint strips, 1507.1.1.3 / R905.1.1.3)

Shakes
(1507.9)
Yes
(joint strips, 1507.1.1.3 / R905.1.1.3)
Yes
(joint strips, 1507.1.1.3 / R905.1.1.3)
Yes
(joint strips, 1507.1.1.3 / R905.1.1.3)

No

No

No

No

No

No

No

No

Yes

Yes

No

No

No

No

No

No

5.6.1 Adhesive-set is limited to use of following underlayment / tile-adhesive combinations.

TABLE 1A: ALLOWABLE UNDERLAYMENT / TILE-ADHESIVE COMBINATIONS1

Underlayment

Adhesive

Ruberoid® Mop Granule; Ruberoid® Mop Granule FR

Dupont "Tile BondTM Roof Tile Adhesive"

Florida Product Approval FL22525

1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.

NEMO ETC, LLC
Certificate of Authorization #32455

7TH EDITION (2020) FBC NON-HVHZ EVALUATION GAF Roof Underlayments

Evaluation Report 01506.04.08-R19 FL10626-R19
Revision 19: 10/19/2020 Page 4 of 8

5.7 Allowable Substrates:

NEMO|etc.

TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS

Underlayment

Application

Primer

Substrates

LibertyTM SBS Self-Adhering Base/Ply Sheet StormGuard® Film Surfaced Leak Barrier Weather Watch® Mineral Surfaced Leak Barrier

self-adhering

(Optional) ASTM D41

plywood

LibertyTM SBS Self-Adhering Base/Ply Sheet

StormGuard® Film Surfaced Leak Barrier

self-adhering None

ASTM D226 felt, Type II

Weather Watch® Mineral Surfaced Leak Barrier

LibertyTM SBS Self-Adhering Base/Ply Sheet

StormGuard® Film Surfaced Leak Barrier Weather Watch® Mineral Surfaced Leak Barrier

self-adhering ASTM D41 metal (flashing metal, valley metal, etc.)

Ruberoid® Mop Granule Ruberoid® Mop Granule FR

hot asphalt

ASTM D41 structural concrete

Ruberoid® Mop Granule Ruberoid® Mop Granule FR

hot asphalt

None

GAFGLAS® #80 UltimaTM Base Sheet or Ruberoid® 20 Smooth

5.8 5.8.1 5.8.2
5.8.3
5.8.3.1 #1

Attachment Limitations:

For use under mechanically attached NON-TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but ­ for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1.

For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but ­ for mechanically attached base sheets - not less than:

· FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1 (for Two-Ply Asphalt Applied Hot Mop Underlayment)

or

· Section 5.8.3 herein (for other underlayment systems).

Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).

Direct-to-Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.

Maximum Design Pressure = -442.5 psf.

Deck:

Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having

Jurisdiction

Base Sheet: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Ply 4,

Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to

25 lbs/square.

Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type

IV hot asphalt at 20 to 25 lbs/square.

NEMO ETC, LLC
Certificate of Authorization #32455

7TH EDITION (2020) FBC NON-HVHZ EVALUATION GAF Roof Underlayments

Evaluation Report 01506.04.08-R19 FL10626-R19
Revision 19: 10/19/2020 Page 5 of 8

5.8.3.2 #2 #3 #4
5.9

NEMO|etc.

Mechanically-Attached Base Sheet:

The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.

Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements.

Maximum Design Pressure = -45 psf.

Deck:

Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having

Jurisdiction.

Base Sheet: GAFGLAS® #80 UltimaTM Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min.

1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c. at the

min. 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced, staggered center rows in the field

of the sheet.

Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type

IV hot asphalt at 20 to 25 lbs/square.

Maximum Design Pressure = -75 psf.

Deck:

Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having

Jurisdiction.

Base Sheet: GAFGLAS® #80 UltimaTM Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min.

1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c. at the

min. 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced, staggered center rows in the

field of the sheet.

Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type

IV hot asphalt at 20 to 25 lbs/square.

Maximum Design Pressure = -97.5 psf.

Deck:

Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having

Jurisdiction.

Base Sheet: GAFGLAS® #80 UltimaTM Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga., min.

1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch o.c. at the

min. 2-inch wide side laps and 4-inch o.c. at four (4), equally spaced center rows in the field of the

sheet.

Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type

IV hot asphalt at 20 to 25 lbs/square.

Exposure Limitations:

TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, Shingle-Mate® Roof Deck Protection, StormSafeTM Anchor Sheet, Tiger PawTM Roof Deck Protection, RoofProTM SBS-Modified All-Purpose Underlayment, VersaShield® Fire-Resistant Roof Deck Protection, LibertyTM SBS SelfAdhering Base/Ply Sheet, StormGuard® Film Surfaced Leak Barrier and WeatherWatch® Mineral Surfaced Leak Barrier
Ruberoid® Mop Granule and Ruberoid® Mop Granule FR

Prepared Roof Cover Installation Type
Mechanically attached
Adhesive-set tile roof system Mechanically attached

Maximum Exposure (days)
30
180 UNLIMITED

NEMO ETC, LLC
Certificate of Authorization #32455

7TH EDITION (2020) FBC NON-HVHZ EVALUATION GAF Roof Underlayments

Evaluation Report 01506.04.08-R19 FL10626-R19
Revision 19: 10/19/2020 Page 6 of 8

NEMO|etc.

5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.

Underlayment Ruberoid® Mop Granule Ruberoid® Mop Granule FR

TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS

Tile Profile

Staging Method

Flat

Max. 10-tile stack

Flat

Max. 6-tile stack (4 over 2)

Lugged

Max. 10-tile stack

Flat or Lugged

Max. 6-tile stack (4 over 2)

Lugged

Max. 10-tile stack

Maximum Staging Slope 4:12 5:12 5:12 5:12 4:12

6.
6.1
6.2
6.3 6.3.1

INSTALLATION:
GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below.
Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application and prime the substrate (if applicable).
Deck-ArmorTM Premium Breathable Roof Deck Protection or Tiger PawTM Roof Deck Protection:
Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception) or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.

6.4 6.4.1

FeltBuster® High-Traction Synthetic Roofing Felt:
Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.

6.5 6.5.1 6.5.2
6.5.3

StormSafeTM Anchor Sheet:
StormSafeTM Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems.
Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception) or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.
One the same day, install LibertyTM SBS Self-Adhering Base/Ply; StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier over the StormSafeTM Anchor Sheet.

6.6 6.6.1

RoofProTM SBS-Modified All-Purpose Underlayment and Shingle-Mate® Roof Deck Protection:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.

NEMO ETC, LLC
Certificate of Authorization #32455

7TH EDITION (2020) FBC NON-HVHZ EVALUATION GAF Roof Underlayments

Evaluation Report 01506.04.08-R19 FL10626-R19
Revision 19: 10/19/2020 Page 7 of 8

6.7 6.7.1
6.8 6.8.1
6.8.2 6.8.3 6.8.4
6.9 6.9.1
6.9.2 6.9.3
7.
8.
9.

NEMO|etc.
VersaShield® Fire-Resistant Roof Deck Protection: Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D6757) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.
LibertyTM SBS Self-Adhering Base/Ply Sheet, StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier: Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. Back-nailing is required. Back-nailing shall consist of Approved cap nails spaced 18-inch o.c., encapsulated within min. 4-inch side laps. When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. LibertyTM SBS Self-Adhering Base/Ply Sheet, StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system.
Ruberoid® Mop Granule; Ruberoid® Mop Granule FR: Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Sections 5.8.2 and 5.8.3 herein for attachment limitations. Refer to Table 4 for tile staging limitations.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards.
QUALITY ASSURANCE ENTITY:
UL, LLC. ­ QUA9625; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -

NEMO ETC, LLC
Certificate of Authorization #32455

7TH EDITION (2020) FBC NON-HVHZ EVALUATION GAF Roof Underlayments

Evaluation Report 01506.04.08-R19 FL10626-R19
Revision 19: 10/19/2020 Page 8 of 8


Adobe Acrobat Standard DC 20.13.20074 Adobe Acrobat Standard DC 20.13.20074