Goodman D Electronic Controls OEM Direct
Goodman Integrated Furnace Controls Models 50T35-743 50A55-743 50M56-743 50M56-707 Control Type IFC Direct OEM Replacement Single Stage Systems PSC Blower Motor IFC Direct OEM Replacement Single Stage Systems PSC Blower…
Goodman Integrated Furnace Controls Models 50T35-743 50A55-743 50M56-743 50M56-707 Control Type IFC Direct OEM Replacement Single Stage Systems PSC Blower Motor IFC Direct OEM
Full PDF Document
If the inline viewer fails, it will open the original document in compatibility mode automatically. You can also open the file directly.
Extracted Text
Goodman Electronic Controls Fast and Easy Direct OEM Replacement for Air Handler, Integrated Furnace and Outdoor Controls D OEM Direct Direct OEM Replacement Control Fast drop-in OEM mounting and wiring. Source with other HVAC Controls Save time by finding these boards at your local HVAC distributor. System Diagnostics for Faster Servicing 7 segment or flashing diagnostic LED aids in quicker and accurate system troubleshooting. Complete Cross Reference Extensive and up-to-date cross reference by OEM model number. Goodman ComfortNetTM Communicating Systems Controls to support legacy 24VAC or communicating system wiring. 50T35-743 50M56-707 50M56-743 Goodman Integrated Furnace Controls NEW Models 50T35-743 50A55-743 50M56-743 50M56-707 Control Type IFC Direct OEM Replacement Single Stage Systems PSC Blower Motor IFC Direct OEM Replacement Single Stage Systems PSC Blower Motor IFC Direct OEM Replacement Single Stage Systems PSC Blower Motor IFC Direct OEM Replacement Single Stage Systems PSC Blower Motor Blower Speeds Heat, Cool Heat, Cool Lo Heat, Hi Heat, Cool Heat, Cool Key Differentiator Versatility 9-pin Main Connector Replaces 9 Parts 7s Ignitor Warm-up Replaces 10 Parts 2-stage Gas Valve Replaces 9 Parts 17s Ignitor Warm-up Replaces 14 Parts Harness Included Yes -- -- -- Diagnostics System Diagnostic LED System Diagnostic LED System Diagnostic LED w/ Fault Recall System Diagnostic LED w/ Fault Recall, Flame Test Pad Mounting Drop-in Replacement Drop-in Replacement Drop-in Replacement Drop-in Replacement Fuse On Board On Board On Board On Board Ignitor Voltage 120V 120V 120V 120V Dedicated Humidification (Optional) 120V or 24V 120V 120V 120V Electronic Air Cleaner (Optional) 120V 120V 120V 120V Heat-on-Delay 30s 30s 30s 30s Heat-off-Delay 90/120/150s 90/120/150/180s 100/150s 100/150s Cool-on-Delay 5s 5s 6s 6s Cool-off-Delay 60s 45s 45s 45s Goodman ComfortNetTM Communicating Systems Models 50C51-707 48C21-707 Control Type IFC Direct OEM Replacement Two-Stage, Variable Speed Blower Motor Communicating or Legacy 24V Systems Air Handler Direct OEM Replacement TwoStage Electric Heat, Variable Speed Blower Motor Communicating or Legacy 24V Systems Versatility Replaces 13 Parts Replaces 13 Parts Harness Included -- -- Diagnostics 7 Segment System 7 Segment System Diagnostic LED Diagnostic LED Mounting Drop-in Replacement Drop-in Replacement Fuse On Board On Board Ignitor Voltage 120V -- Dedicated Humidification 120V -- (Optional) Electronic Air Cleaner 120V -- (Optional) Heat-on-Delay 30s Os (electric) Heat-off-Delay 90/120/150/180s 90s (electric) Cool-on-Delay 5s (legacy) 5s (legacy) Cool-off-Delay 45s (legacy) 60s (legacy) Model 49S25-707 Control Type AC or Heat Pump Direct OEM Replacement Two-Stage Compressor, PSC or ECM Outdoor Fan Motor - Communicating or Legacy 24V Systems Versatility Replaces 11 Parts Harnesses Included -- Diagnostics 7 Segment System Diagnostic LED Mounting Drop-in Replacement Fuse On Board Compressor Short Cycle Delay 3min Compressor Minimum 30s Run Time Field Test Time RV Shift Delay 5s 0/5/15/30s (comm) 30s (legacy) Maximum Defrost Cycle Time 10min Compressor Run Time Until Defrost 30/60/90/120 min Outdoor Fan On/Off Delay 1s 50M56-707 50A55-743 50T35-743 50M56-743 50C51-707 48C21-707 49S25-707 50M56-707 50A55-743 50T35-743 50M56-743 50C51-707 48C21-707 49S25-707 50M56-707 50A55-743 50T35-743 50M56-743 50C51-707 48C21-707 49S25-707 Cross Reference Information Control Number ICM280 ICM286 ICM2810 0130F00005 0130F00005S 0130F00006 0130F00006S B18099-06 B18099-08 B18099-13 B1809913S PCB00109 PCBBF110 PCBBF110S PCBBF112 PCBBF122 PCBBF123 PCBBF132S PCBBF140S PCBBF140 PCBBF138S PCBBF138 PCBBF136S ICM X X X Goodman X X X X X X X X X X X X X X X X X X X X Control Number PCBBF136 X PCBBF135S X PCBBF135 X PCBBF134S X PCBBF134 X PCBBF162 PCBBF162S PCBGR102 PCBGR102S PCBHR103 PCBHR103S PCBHR104 PCBHR104S PCBJA101 PCBJA101S PCBJA102 PCBJA102S PCBJA103 PCBJA103S PCBJA104 PCBJA104S PCBKF101S PCBKF102 PCBKF102S PCBKF103 PCBKF105S X X X X X X X X X X X X X X X X X X X X X Control Number Trane CNT04664 X White-Rodgers 48C21-289 X 48C21-707 X 48C21-290-01 X 48C21-290-02 X 48C21-290-04 X 49C25-289-01 X 49J22-289 X 49J22-289-02 X 49K25-289-01 X 49S25-707 X 50A55-289 X 50A55-743 X 50C51-289-01 X 50C51-289-02 X 50C51-289-90 X 50C51-290 X 50C51-290-01 X 50C51-290-02 X 50C51-290-03 X 50C51-707 X 50M56-289 X 50M56-290 X 50M56-707 X 50M56-743 X 50T55-289 X 50M56-291 X 50M56-281 X 50T35-730 X 50T35-730-1 X 50T35-743 X THE WHITE-RODGERS MOBILE APP: Answers at your fingertips, with your smartphone or tablet. Latest cross reference Installation instructions Spec sheets Product selection R-4610-2 (8/20) �2020 Emerson Electric Co. � White-Rodgers and Emerson are trademarks of Emerson Electric Co. All rights reserved � Customer Service or Technical Help: 888-725-9797 � Emerson.com/White-Rodgers