Document preview
File info: application/pdf · 4 pages · 3.23MB

Highly Efficient Condensing Boiler & Combi Units Features

Read all instructions in this manual before installing. Perform steps in the given order. Failure to do so could result in substantial property damage, severe personal injury, or death. NOTE TO CONSUMER: PLEASE KEEP ALL…

Highly Efficient Condensing Boiler & Combi Units Features

A BRAND OF Features

Full PDF Document

Loading PDF...
Download PDF

If the inline viewer fails, it will open the original document in compatibility mode automatically. You can also open the file directly.

Extracted Text

Fire Tube

ULTRA

�

Highly Efficient Condensing Boiler & Combi Units

Feat u res

DURABLE HEATING - BOILER & COMBI UNITS

Boiler Firing Rates: 85,000, 110,000, 150,000, 199,000 Btuh

Combi Firing Rates: 110,000, 150,000, 199,000 Btuh

Vertical down fired Stainless Steel Heat Exchanger for exceptional efficiency, low pressure drop, and durable performance

ABSOLUTE EFFICIENCY

Up to 96% AFUE while using an outdoor sensor (included)

10:1 turndown ratio limits short cycling and provides more efficient energy consumption

Built-in automatic bypass eliminates expensive primary / secondary piping

Equipped with a built-in highly efficient ECM Pump

WHISPER QUIET OPERATION

Thanks to a pump and combustion fan with insulating panels

EASY TO USE INTERFACE

LCD display with digits, symbols, and an intuitive menu to easily set the desired temperature, activate functions, and manage different heating zones

COMBI BOILER: FULL COMFORT SETTING

Domestic hot water preheat function for instant hot water
SMART CONNECTIVITY WITH HTP LINK

The Elite Ultra boiler is always at your fingertips with a WiFi gateway on board, allowing the boiler and its many system parameters to be monitored remotely

Set up real-time service notifications and maintenance alerts to ensure that the unit is regularly monitored, overdue for maintenance, or if professional assistance is recommended

EASY TO SERVICE WITH QUICK SNAP COMPONENT AND SENSOR CONNECTIONS

ASSE 1017 & 1070 CERTIFED THERMOSTATIC MIXING VALVE INCLUDED WITH COMBI UNITS

FIFTEEN (15) YEAR LIMITED WARRANTY

A BRAND OF

A Look Inside the EFTU-85 - 199K BTU Combi/Boiler

24 25

1.

Pressure relief valve

1

2.

Air purge valve

3.

Boiler outlet temperature sensor

4.

Air pressure switch

23

5.

Flue gas temperature sensor

22

2

6.

Main heat exchanger

18

7.

Flame detection electrode

7

8

Silencer

5

9.

Junction box

10. DHW Heat Exchanger (Combi Models Only)

21

4

11.

Condensate trap

12.

Gas valve

13.

Control panel

12

3

15.

Circulation Pump

8

16. DHW Flow Sensor (Combi Models Only)

17.

Water pressure switch

18.

Modulating Fan

6

20

19.

Boiler inlet temperature sensor

20.

Frame

9

21.

Ignition electrode

22.

Spark generator

23.

Combustion Analysis Test Point

19

24.

Air intake connection

26

25.

Exhaust vent connection

26.

Diverter valve

10

15

11

13

17

16

Vertical Fire Tube Heat

Exchanger

� Features robust SA-240 S43932 Chromium stainless steel

� Down-Fired design resists combustion

chamber fouling better than other heat

Up to

exchanger types

96

� Resists scale build-up and magnetite formation, increasing heat exchanger life and reducing maintenance

� Innovative dimpled tubes extract more heat while remaining compact, without the need for inserts that degrade over time

Water Circuit Diagram

Combi Models

Boiler Models

BCD E

A

1.

Pressure relief valve

2.

Air purge valve

3.

Boiler outlet temperature sensor

4.

DHW Temperature Sensor

5.

Flue gas temperature sensor

6.

Main heat exchanger

7.

Flame detection electrode

8

Silencer

10.

DHW heat exchanger

11.

Condensate trap

12.

Gas valve

15.

Circulation Pump

16.

DHW Flow Sensor (Combi Models Only)

17.

Water pressure switch

18.

Modulating Fan

19.

Boiler inlet temperature sensor

21.

Ignition electrode

24.

Air intake connection

25.

Exhaust vent connection

26.

Diverter valve

27.

By-pass

29.

Pressure gauge

C

AF

E

B

D

CAPTION

A

Central Heating Supply

D

DHW Cold Inlet

B

DHW Hot outlet

E

Central Heating (and Indirect Water Heater) Return

C

Gas inlet

F

Indirect Water Heater Supply

Figure 1 - Water Circuit Diagrams

Specifications

Model

EFTU-85WBN EFTU-110WBN EFTU-150WBN EFTU-199WBN EFTU-110WCN EFTU-150WCN EFTU-199WCN

Type

Boiler

Boiler

Boiler

Boiler

Combi

Combi

Combi

Installation

Indoor, Wall Hung, Fully Condensing

Minimum / Maximum Input (Btu/Hr)1

DOE AFUE2 (%)

Heating Capacity1, 2 (MBH)

Net AHRI Rating, Water (MBH)2

Hot Water Capacity

35oF Rise 45oF Rise 77oF Rise

8,500 / 85,000
96 79 69
N/A

11,000 / 110,000
95 101 88
N/A

15,000 / 150,000
95 138 120
N/A

19,900 / 199,000
95 184 160
N/A

11,000 / 110,000
95 101 88 5.8 4.5 2.6

15,000 / 150,000
95 138 120 7.9 6.1 3.6

19,900 / 199,000
95 184 160 10.5 8.2 4.8

Flue System

Category IV, Sealed Combustion Direct Vent, Power Vent

Minimum - Maximum Exhaust Vent Run3 Minimum - Maximum Intake Air Pipe Run3
Approved Exhaust Vent Materials3

2" (6 - 100 feet), 3" (6 - 150 feet) 2" (0 - 100 feet), 3" (0 - 150 feet)

3" (6 - 150 feet) 2" (6 - 100 feet), 3" (6 - 150 feet) 3" (6 - 150 feet) 3" (0 - 150 feet) 2" (0 - 100 feet), 3" (0 - 150 feet) 3" (0 - 150 feet) PVC, CPVC, PP, Stainless Steel

Shipping Weight (lbs)

110

110

120

131

110

121

132

Gas Supply

NG

Pressure

LP

3.5" to 10.5" WC 8" to 13" WC

Power Supply

General Operating Conditions

Ignition System

Burner System

Gas Valve System

W

Dimensions (in Inches)

H

D

120V, 60 Hz, less than 12A

Ambient Temperature Range: 33 � 104oF (0.6 � 40oC) Product Approvals and Requirements: ANSI Z21.13 / CSA 4.9
ELU Direct Electronic Spark Ignition / Flame Rectification
Premixed Fuel Modulation / Stainless Steel Burner
Air Ratio Valve

17

EELLUU ELU 19.75
Residen3t8i.a25l Condensing Gas B oRilersidential Condens

18.5

17

18.5

Approx. Full Boiler Weight (lbs)

Insta10l7lation 107

RReessi1id2d2eennttiiaallICCnoo1s3ntn9ad.5dleRleanentssiiiondnngegnG1Gt0ai7assl BCBooinillederre12n8.s5ing

G

140.5
as Boiler

Boiler Water Content (Gallons)

1.4

1.4

2.0

2.8

1.5

2.1

2.8

Boiler Setpoint Temperature Range Commissioning 68 � 122oF Low TempeCraotumre /m86i-s1s79iooFnHiignhgTemperature

DHW

Indirect

Setpoint Range

TempIeInrnastsuttraealllaattiioonn

Installation

104 � 149oF

DHW Setpoint Range (Combi Models) Maintenance

M9a7i�n1t49eonF ance

Heat ExchanCgCeoroMmmAWmmPiissssiioonniinnggCommissioning

50

Parts Water Pressure (PSI)

Pressure Relief Valve

Part3s0

DHW Max MPMreasasiuinrnetteennaannNcc/eAe MaiNn/AtenanceN/A

N/A

150

150

150

Control Panel / Main Controller

Connection Sizes

CH Supply / Return
DHW Inlet /PPOauatrrletttss
Gas Inlet

Warranty Parts

AristonThermo LCD Display / AristonThermo GALEVO2 Control
W1 1/a4"rMraalenNtPyT
3/4" Male NPT
3/4" Male NPT

Materials

CabinWeWt aarrrraannttyy
Heat Exchanger

Warranty

Painted Steel SA-240-S43932 Stainless Steel Water Tube

Safety Devices

Flame Rectifier Probe, Temperature Limit Control (190oF), Water Pressure Switch (Min. 8 PSI), Freeze Protection, Blocked Condensate Pressure Switch, Condensate Trap, Flue Temperature High Limit Sensor (210oF), Blocked
Vent Pressure Switch

Table 1 - Technical Specifications

DANGER

DANGER

NOTES:

1 2 3

Listed Input and Output Ratings are at minimum vent lengths at an altitude of 0 - 2000 ft. NuRmeabdearlsl iwnsitlrlubcetiolnoswinerthwisitmhalnounagl beerfovreenintisntagllainngd. P/eorrfoarlmtitsutedpessingRrteheaeadtgaeivlrleitnhsatrnuc2ti0o0ns0ifnt.this manual before installing. P

Ratings based on standard test procedures prescribed by the US Department of Energy. order. Failure to do so could result in substantial property damage, seovredreer.pFearsilounrealto do so could result in substantial prope

The EFTUrequires a special venting system. Use only the vent materials and methods detaileidnjuinryt, horedseeaitnhs. tallation instructions.

injury, or death.

DDAANNGGEERR

DANGER

15 Year Limited Warranty WARNING

WARNING

RReeaaddaallllininsstrturucctImitoionpnsrosipninetrhthinsismtmaalalnanutuiaoalnlb,beaRefdoefojrauerdseitnaminsllestiatnaltslli,ltnirangulg.tce.PtriPeoaerntfrisofornimnr,mstshestirestvepimcpsesai,nnionutrhtamhelebageginvifveotenrneainscteaImclliopnurgol.dpPeveorriifdnosrmtalslatetiposn,inadthjuesgtmivent, alteration, service, o

oordrdeer.r.FFaailiulureretotopdrdoodsusoocctcowouauldrldrarernestsuyulatltninidnscosuarubdubsesstreat.anFpntaritoaiilapul lepreprotrtyopopdedearotrmytysadodgaaecmo,masuageldgeve,r,erseseeuvpveleterreirsneopspneuearbsrlsointonajnaunalrtlyia,ploroprdrdouepcaettrhwty.adrraamntaygaen, dsecvaeurseepperospoenratly damage, severe

ininjujuryr,y,oorrddeeaathth.C. alifornia Proposition 6in5juWrya, ronrindge:aTth.is product contains chemicals knCoawlifnortnoiathPeroposition 65 Warning: This product contain

State of California to cause cancer, birth defects, or other reproductivSethaatermof. California to cause cancer, birth defects, or oth

w

ww.htproducts.com �
In accordance with our company

272
policy

Dof uoncghoianginpreodBucltvidmp, rNoveemwenBtIp,mIpremHorpodTpdrdouProupcfprcteoetWewrsWwrriaeniAdarnrsArvstaRr,ateaRnalNnsMltlaTNyltNtahytIahitINeoAaiOneNonnmdGn,TrdG,icaa�IgcaadnCha�dujuuEjtsfusasetstecomAtptmpurmeorrenoepiantpres,kter,aetetralytostclyetedIphermdnraarravaomatpenmidtorsTaigounagtpcenh,hgetes,se,Wwrese,wsreiarsenirvAgrirevstvirmhvcehtaRitceaeroneertl,Nltoeuo,aoyptotrImpeairNopmernUamsnrrdGkaso,iaoeSoincaninrandptAaeulntjrueolnisonsnideanLtjtaunmijpcuncrLcryeertco,yCn.ecp,oc�theocor,.aProuadtnr0udlyeetdgleeaddle7ivartamsahvot/mhoti.oiid2i.onradnagu2,erpsy,/desTap2rNehtvreve0ioOcesmder2wTe,uaiIo0ptcnChretuomrEsf�suapaotcMientnucatreilKfeniinrcaTjarunetLrcsiyoeeI,nTrocvsor-eud9sledt6ahvtehoi.rdight

to

make

product

c

CCaalilfiofornrniaiaPProroppoonssoitititoiiconen6a65n5dWWwaairlnrlninniongtg: b:TTehhihsCiseapllpdriofrooldiradunbucialctetcPfcoroonrnpttatoyaipsniionstgisocrcnhahep6emh5micicWiacalalserlsnrkrikonnrogsow: wiTnhntliiostoeptrhtrahoeteduurec.tncootnicteaiannsdchweilml nicoat lbsekhneolwdnlitaobtlehefor typographical erro

SStatateteoof fCCaalilfiofornrniaiatotoccaauusseeccaanncceer,r,bbiriStrhtahdtdeefoeffeccCtstas,l,oifororronothitaheetrorrercepapruorsodeduucactitnvivecehrh,aabrmrirmt.h. defects, or other reproductive harm. The surfaces of these products contacted by potable (consumable) waterTchoentsauirnfalecsess of these products contacted by potable (con