I N D E X I } with SD Card N D E X DM - 830L � � 1 Features: �3� Digit Manual Multimeter � Counts 2000 � Battery Test � Max / Min Hold � Data Hold � Auto Power Off � True RMS DC VOLTAGE Range Resolution Accuracy 0.1mV 0.001V 0.01V �0.5%of rdg +3 digits 0.1V 1V DC CURRENT Range Resolution Accuracy 20mA 0.01mA 200Ma 0.1mA �1.2%or rdg +3 digits 10A 0.01A AC VOLTAGE Range Resolution Accuracy 0.1V 1V �1.2%of rdg +5 digits RESISTANCE Range Resolution Accuracy 200 0.1 2k 20k 0.001 0.01 �1.0%of rdg +3 digits 200k 0.1 2M 20M 0.001 0.01 �1.5%of rdg +3 digits Special Function: Diode Test Continuity Power � Standard Accessories Test Lead, Manual � Dimension 151(H) x 75(W) x 45(D) mm DM-830L+ True RMS �0.5%of rdg +4 digits �1.0%of rdg +5 digits �1.0%of rdg +5 digits Special Function hFE test Overload Protection Low Battery Indication CAT II 600V Power � Standard Accessories : Manual, Test Lead � Dimension : 140(H) x 72(W) x 37(D) mm 2 DM-830LN �1.0%of rdg +5 digits �0.8%of rdg +5 digits �0.8%of rdg +1 digits �1.2%of rdg +5 digits True RMS 200mV 2V 20V 200V 1000V 20mA 200mA 10A 20V 200V 750V 0.1mV 1mV 10mV 100mV 1V 10A 100A 10mA 10mV 100mV 1V �1.2%of rdg 5 digits �1.5%of rdg 5 digits 200 2K 20K 200K 2M 20M 200M �1.5%of rdg 5 digits �2%of rdg 5 digits �3%of rdg 5 digits �1.5%of rdg 5 digits 20nF 200nF 2F 200F FREQUENCY �2%of rdg 7 digits 2kHz 200kHz 0.1 1 10 100 1K 10K 100K 10p 100pF 1nF 10nF 0.001kHz 0.1kHz �1.5%of rdg 5 digits �2%of rdg 5 digits �5%of rdg 10 digits �4%of rdg 25 digits �4%of rdg 15 digits �1.5%of rdg 10 digits 20mA 200mA 10A 10A 100A 10mA �2.5%of rdg 5 digits �3%of rdg 7 digits Description Display: Measuring Condition hFE 0~1000 Ibo10A Vce2.8V AA1.5V x 2 3 True RMS True RMS 4 5 DM-97 Features: � 3� Digit Multimeter with Backlight � 3,999 Count � Auto Power Off (APO) under natural operation � Data Hold, Max./Min. � NCV � True RMS DC VOLTAGE Range Resolution Accuracy 400mV 0.1mV 4V 40V 1mV 10mV �0.5% of rdg + 5 digits 400V 100mV 1000V 1V �1.0% of rdg + 5 digits DC CURRENT Range Resolution Accuracy 400�A 0.1�A 4000�A 1�A 40mA 10�A �1.0% of rdg + 5 digits 400mA 100�A 4A 20A 1mA 10mA �2.0% of rdg + 5 digits AC VOLTAGE Range Resolution Accuracy 400mV 0.1mV � 1.5% of rdg + 10 digits 4V 1mV 40V 10mV � 0.8% of rdg + 10 digits 400V 100mV 750V 1V � 1.0% of rdg + 10 digits AC CURRENT Range Resolution Accuracy 400�A 0.1�A 4000�A 1�A 40mA 10�A �1.5% of rdg + 10 digits 400mA 100�A 4A 1mA 20A 10mA �2.0% of rdg + 10 digits RESISTANCE CAPACITANCE Range Resolution Accuracy Range Resolution Accuracy 400 0.1 �0.8% of rdg + 5 digits 40nF 10pF �2.5% of rdg + 6 digits 4k 40k 400k 1 10 100 �0.8% of rdg + 2 digits 400nF 4�F 40�F 100pF 1nF 10nF �2.5% of rdg + 5 digits 4M 40M 1K 10K �1.2% of rdg + 5 digits 400�F 4mF 100nF 1uF �5.0% of rdg + 8 digits FREQUENCY 40mF 10uF Range Resolution Accuracy 10Hz 0.001Hz TRANSISTOR hFE TEST Range Test Range 100Hz 0.01Hz 1000Hz 0.1Hz NPN or 0-1000 PNP Base current is approximate 15�A Vce is about 4.5V 10kHz 1Hz �0.5% of rdg + 4 digits TEMPERATURE 100kHz 1MHz 10MHz 10Hz 100Hz 1kHz Special Function Range Resolution Accuracy -40oC ~ 1000oC 1oC <400oC�0.8% of rdg + 4 digits >400oC�1.5% of rdg + 15 digits -0oF ~ 1832oF 1oF <750oF�1.0% of rdg + 5 digits >750oF�1.5% of rdg + 15 digits Diode Test Function Protection Transistor Testing Input impedance 10M Continuity Buzzer Lower 30+10 Sampling Rate 3 times per second Low Battery Display Lower 2.4V AC Frequency Response 40-400Hz Auto Power OFF Approx. 30 min. Power � Standard Accessories : Test Lead, Manual, TP 01 Temperature Probe Bead type � Dimension : 185(H) x 93(W) x 35(D)mm 6 DM-98 Features : 5/6 DC VOLTAGE Range Resolution Accuracy 0.1mV 0.001V 0.01V �0.5% of rdg + 3 digits 0.1V 1V DC CURRENT Range Resolution Accuracy 600uA 0.1uA 6000uA 1uA 60mA 0.01mA �1.2% of rdg + 3digits 600mA 0.1mA 10A 0.01A AC VOLTAGE Range Resolution Accuracy 600mV 0.1mV 6V 0.001V 60V 0.01V �0.8% of rdg + 5digits 600V 0.1V 750V 1V AC CURRENT Range Resolution Accuracy 600uA 0.1uA 6000uA 1uA 60mA 0.01mA �1.5% of rdg + 3digits 600mA 0.1mA 10A 0.01A RESISTANCE Range Resolution Accuracy 0.1 0.001k 0.01k �1.0% of rdg + 3digits 0.1k 0.001M 0.01M �1.5% of rdg + 3digits TEMPERATURE Range Resolution -20~0oC 0~400oC 1oC 400~1000oC -4~32oF 32~752oF 1oF 752~1832oF Accuracy �5% of rdg + 3digits �1.0% of rdg + 2digits �2.0% of rdg �5.0% of rdg + 6digits �1.0% of rdg + 4digits �2.0% of rdg CAPACITANCE Range Resolution Accuracy 10nF 0.001nF 100nF 0.01nF 10F 10mF 0.1nF 0.001F �4.0% of rdg + 5digits 100F 0.01F 100mF 0.1F 1000mF 0.001mF 1000F 0.01mF �5.0% of rdg + 5digits Special Function : Diode test Continuity Buzzer Power AA1.5V X 2 � Standard Accessories : Manual, Test Lead � Dimension : 188(H) x 88(W) x 58(D) mm FREQUENCY / DUTY Range Resolution Accuracy 0.1Hz 0.001kHz 0.01kHz 0.1kHz �1.0% of rdg + 3digits 0.001MHz Range Resolution Accuracy 1%~99% 0.1% �3% of rdg + 3digits 7 36/7 9V (6F22) X 1 8 DM-83T Features : DIGITAL MULTIMETER DC VOLTAGE Range Resolution Accuracy 200mV 0.1mV 2V 20V 1mV 10mV �1.0% of rdg + 4 digits 200V 100mV 600V 1V �1.0% of rdg + 4 digits AC VOLTAGE Range Resolution Accuracy 1mV �0.8% of rdg + 6 digits 10mV �1.0% of rdg + 6 digits DC CURRENT AC CURRENT Range Resolution Accuracy Range Resolution Accuracy 200uA 0.1�A 200uA 0.1�A 2000uA 20mA 200mA 1�A 10�A 100�A 2000uA �1.0% of rdg + 5 digits 20mA 200mA 1�A 10�A 100�A �1.5% of rdg + 5digits 2A 1mA 2A 1mA 10A 10mA �2.0% of rdg + 5 digits 10A 10mA �2.0% of rdg + 10 digits RESISTANCE TEMPERATURE Range Resolution 200 0.1 2K 1 Accuracy Range Resolution Accuracy -40~1000oC 1oC <400oC�1.0% of rdg + 5 digits >400oC�1.5% of rdg + 15 digits 0~1832oF 1oF <750oFC�1.0% of rdg + 5 digits >750oF�1.5% of rdg + 15 digits 20K 10 �0.8% of rdg + 1 digits Power 200K 2M 100 1K � Standard Accessories : Manual, Test Lead � Dimension : 140(H) x 72(W) x 37(D) mm 20M 10K �1.2% of rdg + 5 digits Features : 5/6 � True RMS � hFE test � Duty cycle test DM-85T DC VOLTAGE Range Resolution Accuracy 600mV 0.1mV 6V 1mV �1.0% of rdg + 4 digits 60V 10mV 600V 100mV �1.0% of rdg + 4 digits AC VOLTAGE Range Resolution Accuracy 6V 60V 1mV 10mV �0.8% of rdg + 6 digits 600V 100mV �1.0% of rdg + 6 digits DC CURRENT AC CURRENT Range Resolution Accuracy Range Resolution Accuracy 600uA 0.1�A 600uA 0.1�A 6000uA 60mA 1�A 10�A 6000uA �1.0% of rdg + 5 digits 60mA 1�A 10�A �1.5% of rdg + 5 digits 600mA 100�A 600mA 100�A 6A 1mA 6A 1mA 10A 10mA �2.0% of rdg + 10 digits 10A 10mA �2.0% of rdg + 10 digits RESISTANCE CAPACITANCE Range Resolution Accuracy Range Resolution Accuracy 600 0.1 �0.8% of rdg + 5 digits 60nF 10pF �2.5% of rdg + 6digits 6K 1 600nF 100pF 60K 600K 10 100 �0.8% of rdg + 1 digits 6F 60F 1pF 10nF �2.5% of rdg + 5digits 6M 1K 600F 100nF 60M 10K �1.2% of rdg + 5 digits 6mF 1F �5.0% of rdg + 8digits 60mF 10F FREQUENCY Range Resolution Accuracy 10Hz 0.01Hz 100Hz 0.001Hz 1KHz 10KHz 1Hz 10Hz �0.5% of rdg + 4 digits 100KHz 100Hz 1mHz 1kHz 10mHz 10kHz TEMPERATURE Range Resolution Accuracy -40~1000oC 1oC <7oC�1.0% of rdg + 5 digits >400oC�1.5% of rdg + 15 digits 0~1832oF 1oF <750oFC�1.0% of rdg + 5 digits >750oF�1.5% of rdg + 15 digits Power � Standard Accessories : Manual, Test Lead � Dimension : 140(H) x 72(W) x 37(D) mm 9 10 � 3� Digit � 2000 Count � True RMS Digit � True RMS �2% of rdg + 5 digits 270(H) x 123(W) x 35(D)mm 11 Features: �3� Digit Clamp Meter with Backlight Manual Range � 1999 Count �Fully Protected in all RANGE �Jaw Open: 52mm � Clamp Torch � True RMS � NCV AC VOLTAGE DC VOLTAGE Range Resolution Accuracy Range Resolution Accuracy 20V 750V 10mV 1V �1.0% of rdg + 5 digits 200mV �1.2% of rdg + 5 digits 20V 0.1mV 10mV �0.5% of rdg + 5 digits 1000V 1V �1.0% of rdg + 5 digits �1.0% of rdg + 5 digits AC CURRENT RESISTANCE Diode Test Range Resolution Accuracy Range Resolution Accuracy Continuity Test 200A 1000A 0.1A 1A �2.0% of rdg + 5 digits 200 2k 0.1 1 �0.8% of rdg + 5 digits Function Protection Sampling Rate 2 or 3 times/sec POWER AAA1.5V x 2 20k 200k 2m 20m 200m 10 100 1k 10k 100 Input Impedance �0.8% of rdg + 1 digits 10M � Standard Accessories : Soft Carrying Case, Manual, Test Lead � Dimension : �1.2% of rdg + 5 digits 123(H) x 270(W) x 35(D)mm CM-2070C 200mV 2V 20V 200V 1000V 200mV 2V 20V 200V 750V 0.1mV 1mV 10mV 100mV 1V 0.1mV 1mV 10mV 100mV 1V �1.0% of rdg + 5 digits AC CURRENT �0.5% of rdg + 5 digits 200A 100mA 1000A 1A �1.0% of rdg + 5 digits RESISTANCE �1.5% of rdg + 5 digits �1.0% of rdg + 5 digits �1.5% of rdg + 5 digits 200 2k 20k 200k 2M 20M 0.1 1 10 100k 1K 10K TEMPERATURE �2.0% of rdg + 5 digits (-40-1000)oC 1oC (0-1832)oF 1oF POWER �0.8% of rdg + 5 digits 9V (6F22) X 1 <400oC+1.0% of rdg + 5 digits >400oC+1.5% of rdg + 5 digits <750oC�1.0% of rdg + 5 digits >750oC�1.5% of rdg + 5 digits �0.8% of rdg + 3 digits �1.2% of rdg + 5 digits � Standard Accessories : Test lead, Manual, Soft Carrying Case TP04 Temperature probe � Dimension : 123(H) x 270(W) x 35(D)mm Digit Clamp Meter with Backlight 4000 Count � True RMS �0.8% �1.0% 4A 1mA 40A 10mA 10 digits �2.5% of rdg + 5 digits 4mF 1 40mF 10 �5% of rdg + 10 digits 10Hz 100Hz 1kHz 10kHz 100kHz 1MHz 10MHz 0.01Hz 0.1Hz 1Hz 10Hz 100Hz 1kHz 10kHz �0.5% of rdg + 4 digits 1 digits �1.0% 12 13 CM-2055 Features: 600V 10A 80A 80~100A 600V 10A 80A 80~100A 10k AAA 1.5V X 2 Continuity Buzzer MAX Test Voltage Overall Protection 0.1V 1mA 10mA 10mA 0.1V 1mA 10mA 10mA 1 �1.0% of rdg + 2 digits �2.5% of rdg + 10 digits �4.5% of rdg + 10 digits �1.5% of rdg + 5 digits �2.0% of rdg + 10 digits �3.5% of rdg + 10 digits �1.0% of rdg + 3 digits <100 Ohm 3V DC 600V rms � Standard Accessories : Manual, Carrying Case, Test Lead � Dimension : 202(H) x 70(W) x 30(D) mm AC/DC CLAMP METER � True RMS 10K 14 � 3� Digit Clamp Meter with Backlight � 2000 Count � Clamp Torch � Jaw Open : 52mm � Auto Power Off (APO) � True RMS � 33/4 Digit Clamp Meter with Backlight � 4000 Count � Clamp Torch � Jaw Open : 52mm � Non Contact Voltage (NCV) � Duty Cycle : 1-99% � Frequency / Tempreature � Auto Power Off (APO) � True RMS 40A 0.01A 0.1A 1A �1.0% of rdg + 5 digits �1.5% of rdg + 5 digits 400 F 4 F 40 F 10K 100mF 1 F 10 F �5.0% of rdg + 10 digits 35(D)mm 40A 0.01A 0.1A 1A �1.5% of rdg + 5 digits 1 �1.0% of rdg + 10 digits 4nF 40nF 400nF 4 F 40 F 400 F 4mF 40mF 10Hz 1pF 10pF 100pF 1nF 10nF 100nF 1 F 10 F 0.01Hz 0.1Hz 1Hz 10Hz 100Hz 1KHz 10Hz �5.0% of rdg + 10 digits �2.5% of rdg + 5 digits �5.0% of rdg + 10 digits �0.5% of rdg + 4 digits (-40~1000)oC AAA1.5Vx2 : 270(H) x 123(W) x 35(D)mm 15 Features: 16 / / 17 Features: � 4 Digit LCD Display with Black Screen � 9,999 Count � Auto Power Off (APO) � Conductor Size: 55mm x 32mm � Data Logging System 300 groups memory � Measure 2 times / sec. � Double Insulation Protection Level � Spare 1 & 10 Test Ring, to detect Self Precision RESISTANCE Range 0.010~0.099 0.10~0.99 1.0~49.9 50.0~99.5 100~199 200~395 400~590 600~880 900~1000 POWER Resolution 0.001 0.01 0.1 0.5 1 5 10 20 30 Accuracy � 1%of rdg + 0.1 digits � 1.5%of rdg + 0.5 digits � 2%of rdg + 1 digits � 5%of rdg + 5 digits � 10%of rdg + 10 digits � 20%of rdg + 20 digits � 25%of rdg + 30 digits � Standard Accessories : Hard Carrying Case, Test Loop, Manual � Dimension : 285(H) x 85(W) x 58(D)mm 18 Features: � Ground resistence test, loop resistence test, AC current test, AC voltage test � Clamp Size 68mm � Display 2.4 inches color LCD screen � Measure Time 1 time/sec � Data Storage Maximum 500 groups of data, display "FULL" symbol to indicate that the storage is full � Auto Power Off (APO) � Spare 1 & 10 Test Ring to detect Self Protection RESISTANCE Range 0.02~9.99 10.0~99.9 100~199 200~299 300~699 700~999 1.00K~1.19K 1.20K~2.00K CURRENT Range 0.100mA~0.999mA 1.00mA~9.99mA 10.0A~99.9A 0.100A~0.999A 1.00A~9.99A 10.0A~60.0A GROUND VOLTAGE Range 1.00V~9.99V 10.0V~99.9V 100V~600V SOIL RESISTIVITY Range 0.00m~99.99m 100.0m~999.9m 1000m~9999m 10.00km~99.99km 100.0km~999.9km 1000km~9999km Resolution 0.01 0.5 1 5 10 20 30 50 Resolution 0.001mA 0.01mA 0.1mA 0.001A 0.01A 0.1A Resolution 0.01V 0.1V 1V Resolution 0.01m 0.1m 1m 10m 100m 1km Accuracy � 2%of rdg � 0.1 digits � 3%of rdg � 0.5 digits � 5%of rdg � 1 digits � 10%of rdg � 5 digits � 15%of rdg � 10 digits � 20%of rdg � 20 digits � 25%of rdg � 30 digits � 35%of rdg � 50 digits Accuracy � 2.5%of rdg � 0.1mA digits � 2.5%of rdg � 0.5mA digits � 2.5%of rdg � 1mA digits � 2.5%of rdg � 0.1A digits � 2.5%of rdg � 0.5A digits � 2.5%of rdg � 1 digits Accuracy � 2.5%of rdg � 0.1V digits � 2.5%of rdg � 1V digits � 2.5%of rdg � 5V digits Accuracy p=2naR (note1) 3.7V Lithum X 1 Standard Accessories : Test line 4 pcs, Single test time 2 pcs Hard Carrying, Manual, Test loop Dimension : 273(H) x 106(W) x 53(D)mm 19 20 AC IV Features: � Display LCD with Bargraph � Backlight Red & Green Double Colour � Signal Intensity four level � Flash Light No operation sensing signal will shutdown � Auto Power Off (APO 3 minutes) PSD II Features : � Compact, easy-to-wear and convenient to use. � Indoor and outdoor use � Equipped with self-testing functions. � Audio indications. � Able to sense a wide variety of AC high � Voltage systems. � Low power consumption. Specification : � Dimension : 157(H) x 27(W) x 23(D) mm � Weight : Approx 32 g (OPTIONAL) 21 HP-500 NON-CONTACT HIGH VOLTAGE DETECTOR Technical Data : Basic Functions Frequency Range Voltage Ranges OFF TEST POWER Standard Accessories Dimension Range 40 ~ 70 Hz 240V-69kV-115kV-138kV-230kV-500kV 9V (6F22) X 1 Manual & warranty card 115 (D) X 115 (W) X 169 (H) mm Features : � 9 Voltage Settings � Bright LED Visual INDICATION with Buzzer � Protection class IP65 � Non-Contact Test Detection by Proximity � Light Weight, Robust and Compact � The Max Detection Range Can be 500 kV � The measuring wire is Horizontal with the lighting lamp placed vertical to it. V. Instrument structure 22 9V (6F22) X 1 9V (6F22) x 1 23 Power : 9V (6F22) X 1 24 Manual 25 1 LX-103 26 SOUND LEVEL METER / CALIBRATOR (advanced Software program for all Windows) CAL-900 Standards Sound Pressure Accuracy Frequency Application Temperature Coefficient Altitude Effects Temperature Range Power Dimension Weight GB/T15173, IEC942 94 dB and 114 dB 0.3 dB 1000�0.01% Hz allows calibration with A,B,C or D weighting networks or linear. Calibration of 1" and 1/2" microphones 0 to 0.01 dB/oC Approximately 0.1dB decrease for each2000 feet increase in altitude from sea level to 12,000 feet elevation, or comparable atmospheric pressure charge (approximately every 50mm of Hg decrease) -10 to = 50oC (operating) -40 to =65oC (storage with batteries removed) AAA 1.5V X 4 (UM - 4) 137 x 51 x 51mm 200g 27 0.40~30.00 m/s 0.01 m/s �2.0% of rdg + 0.5m/s 0.01~0.1 �2.0% of rdg + 1.8Km/h Km/h 0.01 ft/s �2.0% of rdg + 1.6 ft/s 0.01 knots �2.0% of rdg + 1.0knots 0.90~67.10 miles/h 0.01 miles/h �2.0% of rdg + 1miles/h 0.01~1 ft/m �2.0% of rdg + 10ft/m 0~9999 0.01~1 Soft Carrying Case, AAA 1.5V X 4 28 29 30 31 32 9V (6F22) X 1 Features: Technical Data : Basic Functions Ambient Temperature Range -20~60oC (-4~140oF) RH WB (Wet bulb Temperature) DP (Dew point Temperature) POWER 0~100%RH -20~60oC (-4~140oF) -50~60oC (-58~140oF) Resolution 0.1 oC / oF 0.1% 0.1 oC / oF 0.1 oC / oF Accuracy �1.0oC (0~45oC) �1.5oC(-20~0oC, 45 to 60oC) �2.0% RH(20%~90%) �4.0% RH(0~10%,80~100%) �1.0oC (0~45oC) �1.5oC(-20~0oC, 45~60oC) �1.0oC (0 to 45oC) �1.5oC(-50~0oC, 45~60oC) � Standard Accessories : Hard Carrying Case, Manual � Dimension : 184(H) x 60(W) x 29(D)mm 33 9V (6F22) X 1 34 Features: � �C or �F Selection � Circular Laser � Auto Power Off (APO) � Colour LED Display � High Alaram Indicators Accuracy MTX1 -50 ~ 550�C/58~1022�F -30�C-0�C(-22�F-32�F), �3�C 0�C-55�C(-22�F-1022�F), �(1.5%+2�C) Distance Spot Ratio Emissivity Resolution 12:1 adjustable 0.1~1.0 0.1�C / 0.1�F POWER AAA 1.5V x 2 � Standard Accessories : Manual � Dimension : 43(H) x 155(W) x 160(D)mm MT4 Features: � oC or oF Selection � Circular Laser � Auto Power Off (APO) � Colour LCD Display � LCD Alaram Indicator MTX2 -50�C ~ 580�C -58~1076�F Accuracy 50~0�C / -58~32�F; �4�C/7.2�F 0-550�C / 32~1022�F; �2%(�2�C/3.6�F) Distance Spot Ratio Emissivity Resolution 13:1 adjustable 0.1~1.0 0.1�C / 0.1�F POWER 9V (6F22) X 1 � Standard Accessories : Soft Carrying Case Manual � Dimension : 155(H) x 99(W) x 28(D)mm MT6 Features: � oC or oF Selection Circular � Circular Laser � Auto Power Off (APO) � Data Hold Function � Colour LCD Display Distance Spot Ratio Emmissivity Spectral Response Resolution POWER 9V (6F22) X 1 -20oC to 0oC/-4oF to 32:4oC/7oF Above 0oC/32oF:�2%of reading�2oC/3.6oF 12:1 adjustable 0.1 ~ 1.0 8 ~ 14um 0.1oC / 0.1oF � Standard Accessories : Soft Carrying Case, Manual � Dimension : 132(H) x 55(W) x 168(D)mm MT8 Features: � oC or oF Selection � Colour LCD � Auto Power Off (APO) � Circular Laser � Data Hold Function Features: � oC or oF Selection Circular � Circular Laser � Auto Power Off (APO) � Data Hold Function � Colour LCD Display Technical Data : Basic Functions Temperature Range Accuracy Distance Spot Ratio Emissivity Spectral Response Resolution POWER 9V (6F22) X 1 MT6 -50 ~ 750oC / -4~1382oF � 2.0% of rdg+2oC digits 12:1 adjustable 0.1~1.0 (8~14)um 0.1oC / 0.1oF � Standard Accessories : Soft Carrying Case, Manual � Dimension : 132(H) x 55(W) x 168(D)mm Relative Humidity Accuracy Distance Spot Ratio Emmissivity Spectral Response Resolution POWER MT-8 / 0~99%RH 5%RH 12:1 adjustable 0.10~1.00 8~14um 0.1oC / 0.1oF � Standard Accessories : Manual � Dimension : 148(H) x 102(W) x 46 (D)mm 35 Automatic High & Low Alarm Auto Power Off (APO) Response Time -50~500�C -58~932�F < 250 ms Round Features: Professional High Temperature Infrared Thermometer � User Selectable oC or oF � Circular Laser Targeting � Automatic Data Hold � Over Range Indication � Trigger Lock � Type K Input � USB interface � Colour LCD Display with Backlight � Auto Power Off (APO) Dimension : 192(H) x 120(W) x 59(D) mm 36 < 250 ms 1.5% BODY SCAN - II Model Temperature range Basic accuracy Optimum measuring distance Response time Optical response Auto shutdown Low battery indication High-temperature alarm Data hold Unit conversion (C/F) Operating environment Transport and storage environment Scan II 32oC~42oC (89.6oF~109.2oF) �0.3oC (�0.6oF) 5cm ~ 10cm 500ms 8 m~14 m 3 3 Sound alaram for >32.7oC/98.96oF 3 3 15oC~30oC(59oF~86oF)<85%RH -20oC~60oC(-4oF~140oF), <85%RH 37 VT-110 Features: THERMAL IMAGER Specification : IR Resolution 33x33 (1089 pixels) Display Resolution 240*320 pixels Visual Image Resolution Field Angle Infrared Temperature Range Accuracy Dew Point Temperature Range Accuracy Wet Bulb Temperature Range Accuracy Thermal Sensitivity Emissivity Image Frequency 300,000 pixels 32 X 32o -20-380oC/-4-716oF >0oC, �2% or reading �2oC/3.6oF <0oC, �3oC/5.4oF Note: Accuracy is measured in an enviroment of 18-28 degree -30~100oC/-22~212oF �1.0oC/1.8oF (25oC/77oF,35~ 70%RH) -30~100oC/-22~212oF �1.0oC/1.8oF (25oC/77oF,35~ 70%RH) 0.15oC/0.27oF Adjustable 0.1-1.0 9HZ Wavelength Range 8-14um Focus Mode Fixed Palette Ink colour, black and white, rainbow colour, ocean blue, iron red View Options File Format Bleeding of the visual and the infrared from full infrared to full visual in 25% steps BMP Storage 8GB Micro SD Card Memory View Scroll all saved images and view them on the screen USB function Connect USB cable with PC, meter works as U Disk, stored data in SD cared can be download to other power supply and meter. USB can power supply to the meter directly and meter works as usual during this time. Auto Power Off 3 minutes, 5 minutes, 10 minutes are optional Working Temperature -5~40oC/23~104oF Storage Temperature Range -20~55oC/-4~131oF Relative Humidity Power 10~80%RH AA 1.5V X 4 & USB Power Supply 38 � Thermocouple Calibrator � Accuracy �0.02% � Power : 9V (6F22) X 1 CALIBRATOR Features: OHM Measurement : Output Range 4 Wire 0.00-400.00 0.1 400.0-1500.0 0.5 1500.0-3200.0 1.0 INPUT ACCURACY � 2 Wire & 3 Wire 0.15 1 1.5 OHM Simulate : Range Output accuracy � 0.00-400.00 0.1 400.0-1500.0 0.5 1500.0-3200.0 1.0 Allow Excitation(mA) 0.1~3.0 0.05~0.8 0.05~0.4 RTD Specification : RTD Type Range �c(�f) PT10(385) PT50(385) PT100(385) PT200(385) Pt500(385) Pt100(385) Pt100(385)J IS -200.0~800.0 (-328.0~1472.0) -200.0~800.0 (-328.0~1472.0) -200.0~800.0 (-328.0~1472.0) -200.0~630.0 (-328.0~1166.0) -200.0~630.0 (-328.0~1166.0) -200.0~630.0 (-328.0~1166.0) -200.0~800.0 (-328.0~1472.0) Accuracy (�C) Input 4w 2w/3w Output 1.5 1.5 1.5 0.3 0.5 0.5 0.3 0.4 0.4 0.2 0.4 0.4 0.2 0.4 0.4 0.2 0.4 0.4 0.3 0.4 0.4 Allowable Excitation(mA) 0.1~3.0 0.1~3.0 0.1~3.0 0.1~3.0 0.05~0.8 0.05~0.4 0.1~3.0 39 CC-09 MULTIFUNCTION CALIBRATOR / FORCE GUAGE Features: � 5� Digit LED � Calibration of DC Volt, Amp Meters � Calibration of AC Volt, Amp Frequency Meters � Calibration of Resistance Meters, Clamp & Multi Meters Technical Data: Output Range Accuracy Voltage Current Frequency 100�A, 500�A, 2.5mA, 10mA, 25mA, 100mA, 250mA, 1A, 2.5A, 10A, 50A 50Hz, 60Hz, 400Hz, 1kHz DCI: �(0.03% of reading +0.02% FS) ACI: �(0.05% of reading +0.03% FS) <0.1% Turns Ratio Input Max. Current Clamp Jaw DC Impendence DC Burden AC Burden Frequencies Accuracy Resistance 10, 24, 50, 100, 240, 500() 1, 2, 4, 5, 10, 25 (k) 10x1k, 24x1k, 50x1k 100x1k, 240x1k, 500x1k, 1kx1k, 2.4kx1k, 5kx1k, 10kx1k, 24kx1k �(0.2% of reading +20m) Special Function : Stability Ripple Power Supply Distortion DC : <0.01%FS / 3 min. AC : <0.02%FS / 3 min. <0.2% 230V AC, 50 (60) Hz <0.5% � Standard Accessories : Key Adjuster, Power Cod, Pair of Output Leads 50A, Briefcase, Optional Accessories Standard Current Coil � Dimension : 190(L) x 480(W) x 545(H)mm 40 mbar 0.1 0.1 0.1 0.1 1 1 1 0.1 0.1 Power : 9V (6F22) X 1 mbar 41 42 43 44 45 DC REGULATED POWER SUPPLY 46 9V (6F22) X 1 47 Units of measurement : meters (m) /hpa ALTIMETER / DISTANCE METER UDM-01 Features: � With laser pointer � Foot/Meter display options � LCD screen with LED backlight � Support sum-up, multiplication and subtraction of 2 measurement data. � All stored measurement data can be cleared. � Altitude history & Graphical Display of the last 12 hour altitude readings. � Total Altitude Gain & Loss � Max./Min. memory for Altimeter and Barometer Pressure � Barometer Pressure History & Graphical Display � Electronic barometer Weather Forecast(Sunny, Slightly Cloudy, Cloudy, Small Rain, Large Rain) � Pressure Trend Indicators � Perpetual Calendar with day of week � 12/24 hour selectable � Low battery indication 48 Technical Data Basic Function Measurement Range Auto shutdown Memory Accuracy Ultrasonic Frequency Working temperature Laser beam: Wattage Wavelength POWER 9V (6F22) X 1 Range 0.5~18m After 15 seconds without pressing any key can store 3 measurement data for calculation of area and volume �0.5% 40 kHz 0oC~43oC 1mW 650nm � Standard Accessories : Soft Carrying Case, Manual � Dimension : 142(H) X 73(W) X 47(D)mm Features: LD-40 / LD-70 / LD-100 � Area/Volume measurement function � Pythagorean proposition measurement function � Add and subtract measurement function � Continuous measurement function Specification : Basic Function Range Distance Measurement Precision Measurement Unit Options Area Volume Funtion Volume Measurement Function Automatically Cut Off Laser Automatic Shutdown POWER AA 1.5V X 2 LD-40 0.05-40m LD-70 0.05-70m �1.5mm mm/in/ft � � 20s 150s � Standard Accessories : Soft Carrying Case, Manual � Dimension : 118(H) X 53(W) X 26(D)mm LD-100 0.05-100m 49 50