SEACE EHS Catalogue 2020 2021-XX dr01bw

EHS

Installers | Climate Solutions | Samsung Business Ireland

PDF preview unavailable. Download the PDF instead.

SEACE EHS Catalogue 2020 2021-spread LR dr01bw
Product Catalogue
Eco Heating Systems

Introduction Introduction

Highlights for 2020-2021
WindFreeTM
Samsung extends its WindFreeTM Technology with a completely new WindFreeTM wall-mounted model for its EHS TDM Plus product range. The latest TDM Plus WindFreeTM Deluxe is equipped with WindFreeTM Cooling technology, spreading fresh air gently and evenly through thousands of microholes to create "Still Air" conditions1.

TDM Plus WindFreeTM Deluxe

NEW

WindFreeTM Cooling

Wi-Fi Control (optional)

Fast Cooling

· Equipped with NASA communication protocol. · Available in capacity range 2.2-5.6 kW with optional EEV kit.

Wi-Fi Control
The new optional Wi-Fi Kit allows users to control up to 16 connectable indoor units via smartphone with the Samsung SmartThings app2. The app checks indoor temperature, outdoor temperature and air quality levels, and then recommends the optimal operating mode. It also offers the option of adding user scenes such as working, walking or resting. The geofencing functionality allows the room temperature to be automatically set at the desired level when the user approaches within a preset distance of 100 m - 150 km from the building.
Wi-Fi Kit
· Wi-Fi control up to 16 indoor units through Samsung SmartThings. · Welcome Cooling or Heating through geofencing functionality. · Individual energy monitoring for up to 16 outdoor units. · The voice command feature is available through a smartphone with Bixby3.

NEW
1 ASHRAE (the American Society of Heating, Refrigeration, and Air-Conditioning Engineers) defines "Still Air" as air currents moving at speeds below 0.15 m/s, with no cold drafts. 2 A Wi-Fi connection and Samsung SmartThings application account are required. Wi-Fi Kit to be ordered separately. Requires iOS 10.0 or later & Android 5.0 or later. 3 Currently Voice control is supported in English (US, UK, Indian), Chinese, Korean, French, German, Italian, Spanish and Portuguese.
2

ClimateHub TDM Plus
The Samsung EHS (Eco Heating System) extends the compact and modular Tank Integrated Hydro Unit for TDM Plus in addition to Mono and Split. The ClimateHub with Tank Integrated Hydro Unit saves space, but also reduces the time of installation. With a 2-zone control and advanced functions, energy efficiency and sustainability performance are optimised. Its Time Division Multi Operation means it can supply hot water while also cooling spaces.
ClimateHub TDM Plus

Floor heating

Radiator

Hot water

Quiet operation

· Compact unit size with large water tank (200 L and 260 L). · Intuitive, colour screen touch controller in multiple languages1. · Energy monitoring through touch controller. · 2-zone control, suitable for floor heating and radiators. · SmartThings compatible with optional Wi-Fi kit2. · Backup heater is included to ensure continuous heating. · Solar Power (PV) and Smart Grid ready. · Smooth servicing through the front-mounted service window.

Smooth installation

Wi-Fi Control (optional)

NEW

1 Available languages: English, German, Spanish, French, Italian and Polish. 2 A Wi-Fi connection and Samsung SmartThings application account are required. Wi-Fi Kit to be ordered separately. Requires iOS 10.0 or later & Android 5.0 or later.
3

Introduction Introduction

Product overview

Mono
The EHS Mono can connect to third party equipment such as a Domestic Hot Water (DHW) tank thanks to the Samsung Mono control kit. The Mono Control kit includes a controller, flow sensor, DHW sensor and leaving and return water sensors.
Split
The EHS Split outdoor unit is connected to a wall-mounted Hydro Unit to combine with a third party Domestic Hot Water (DHW) tank to suit all requirements. When used with the Hydro Unit, the Split enables production of domestic hot water and underfloor heating/ cooling, and heating of radiators.
TDM Plus
The EHS TDM Plus outdoor unit can connect to a third party Domestic Hot Water Tank (DHW) via a wall-mounted Hydro Unit. TDM Plus with a third party connection offers A2W and A2A home climate comfort.

Third party DHW Tank

Outdoor Unit

Wi-Fi Kit

Hot Water

3-Way Valve + Pump

Control Kit
Mixing Valve + Pump

Touch Controller
Zone 1 - Radiator

Zone 2 - Floor Heating

Solar Panel

Third party DHW Tank

Outdoor Unit

3-Way Valve
Hydro Unit

Hot Water Wi-Fi Kit

Mixing Valve + Pump

Touch Controller

Zone 1 - Radiator

Zone 2 - Floor Heating

Solar Panel

Outdoor Unit

EEV Kit
3-Way Valve

Indoor Unit Third party DHW Tank
Hot Water
Wi-Fi Kit

Hydro Unit

Mixing Valve + Pump

Touch Controller

Zone 1 - Radiator

Zone 2 - Floor Heating

Schematic drawings are for illustrative purposes only. For accurate installation information please consult the technical data book. The selection of the exact product is subject to specific application conditions. Solar panels, underfloor heating panels, radiators and non-integrated components are not provided by Samsung unless specified otherwise. For more detailed product information and technical specifications, please consult the respective product pages of this Product Catalogue.
4

Indoor Units

Available Samsung product range Outdoor Units

Controls

Tank Integrated

Wall-Mounted

Third party

R32

Hydro Unit

Hydro Unit

DHW Tank

Wireless

Wired

Centralised

Wall-Mounted

Duct

Indoor Units

Console

R410A

Mono Control Kit

Wi-Fi Kit

Available Samsung product range Outdoor Units

Controls

Tank Integrated

Wall-Mounted

Third party

R32

Hydro Unit

Hydro Unit

DHW Tank

Wireless

Wired

Centralised

Wall-Mounted

Duct

Indoor Units

Console

R410A

Mono Control Kit

Wi-Fi Kit

Available Samsung product range Outdoor Units

Controls

Tank Integrated

Wall-Mounted

Third party

R32

Hydro Unit

Hydro Unit

DHW Tank

Wireless

Wired

Centralised

Wall-Mounted

Duct

Console

R410A

Mono Control Kit

Wi-Fi Kit

5

Introduction Introduction

Product overview

ClimateHub Mono
The ClimateHub Mono configuration has a single outdoor unit that includes the hydronic system, making it easy to install and use. The system's potential can be maximised by connecting to Smart Grid or Solar Power (PV).

Solar Panel

Outdoor Unit

Wi-Fi Kit

Hot Water

Mixing Valve + Pump

Touch Controller

Tank Integrated Hydro Unit

Zone 1 - Radiator

Zone 2 - Floor Heating

ClimateHub Split
The ClimateHub Split configuration has a single outdoor unit, connected by refrigerant pipes to the tank integrated hydro unit. To maximise its potential, the system can be connected to Smart Grid or Solar Power (PV).

Outdoor Unit

Wi-Fi Kit

Hot Water

Mixing Valve + Pump

Touch Controller

Tank Integrated Hydro Unit

Zone 1 - Radiator

Zone 2 - Floor Heating

ClimateHub TDM Plus NEW
The TDM Plus system is an `All-In-One' Airto-Water (A2W) and Air-to-Air (A2A) system for a complete home climate solution. It can be used throughout the year for cooling and heating to meet a variety of different user situations and needs. It enables underfloor heating/cooling and radiator heating, as well as offering A2A cooling with various options for air conditioning. The system's potential can be maximised by connecting to Smart Grid or Solar Power (PV).

Solar Panel

Indoor Unit

Outdoor Unit

EEV

Hot Water

Kit

Wi-Fi Kit

Mixing Valve + Pump

Touch Controller

Tank Integrated Hydro Unit

Zone 1 - Radiator

Zone 2 - Floor Heating

Schematic drawings are for illustrative purposes only. For accurate installation information please consult the technical data book. The selection of the exact product is subject to specific application conditions. Solar panels, underfloor heating panels, radiators and non-integrated components are not provided by Samsung unless specified otherwise. For more detailed product information and technical specifications, please consult the respective product pages of this Product Catalogue.

6

Project: Atico en el Retiro (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Belén Imaz
7

Introduction Introduction

Project: Casa L (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Carlos Muntadas
8

Table of contents

Introduction Samsung Climate Solutions at a glance Reference projects in the spotlight Regulations and Standards Certifications NEW
Eco Heating Systems (EHS) Product Line-up Selecting the right heating system Nomenclature ClimateHub Features
Mono ClimateHub Mono Mono with Third Party DHW Tank
Split ClimateHub Split Split with Third Party DHW Tank
TDM Plus ClimateHub TDM Plus NEW TDM Plus with Third Party DHW Tank TDM Plus WindFreeTM Deluxe NEW TDM Plus Slim Duct TDM Plus MSP Duct TDM Plus Console

Controls Line-up Features
Accessories Line-up
Design and support Samsung Climate Solutions Partner Portal DVM Pro 2.0 NEW Samsung Climate Solutions Academy Hydraulic Schematics NEW

This document may either contain preliminary values or may lack some values that were not yet available at the time of creation. To obtain the latest information, please consult the Samsung Climate Solutions Partner Portal at partnerhub.samsung.com/climate or contact your direct Samsung representative.
9

Introduction Introduction

Samsung Climate Solutions at a glance

The solutions that we offer

At Samsung, we focus on providing cutting-edge innovations in indoor climate comfort and being a leader in intelligent digital connectivity solutions.

Cooling

Heating

Hot water

Ventilation

Our marketcentric product ranges

Residential Light Commercial Commercial Heating Controls

Home
RAC | FJM
CAC | FJM

Hotel

Retail

Office

Restaurant

Education

CAC DVM | HVM | ERV

EHS

CONTROLS

Expert training

Marketing platforms

Project design

Technical support

Spare parts

10

Services we provide to empower our partners

Corporate and Technology milestones that make us proud

1974
Samsung introduces its first air conditioner.
2014

2005
Samsung Electronics enters the European market for commercial air conditioning.
2015

2017
Samsung Electronics opens Samsung Electronics Air Conditioner Europe B.V. (SEACE) in Amsterdam.
2017

Arrival of the Samsung TDM concept, an all-in-one heat pump solution for heating, cooling and domestic hot water supply.

Introduction of the Samsung 360 Cassette, the world's first circular air conditioner that fits seamlessly into the design of any space.

Samsung WindFreeTM technology comes onto the market, gently and evenly dispersing fresh air through thousands of micro-holes to limit cold drafts.

Our flagship

innovations

that

enrich

WindFreeTM Cooling

Wi-Fi Control

Building Management System

people's lives

Our European footprint with the locations from which we operate

1 | Samsung Electronics Air Conditioner Europe B.V.

16 | Samsung offices

8 | Warehouses

9 | Training centres

11

Introduction Introduction

Samsung reference projects in the spotlight
Project Etopia
12

Joseph Daniels
CEO Project Etopia Group
"A big step in our Samsung partnership is working collaboratively on the heat pump technology. Through this partnership we are able to provide not only heating, cooling and hot water, but we can do this all whilst utilising renewable energy sources. Our class leading pilot project at the BRE innovation park in Watford, UK, uses this system and has been engineered to be more than energy positive. The real game changer for this product specifically is the ability to intelligently control and harmonise it with our smart home system, providing unseen thermal, energy and environmental control with a positive impact on both cost savings and lifestyle."
Application

Residential
Samsung products installed

TDM Plus Outdoor Unit

Wall-Mounted Hydro Unit

SmartThings

13

Introduction

Regulations and standards

Samsung strives to provide customers with new eco-friendly experiences and lead the way to a sustainable future for the global community through innovative and eco-friendly products and technology. We monitor applicable environmental standards and laws and regulations in the context of our climate solutions operations. Samsung also conducts environmental improvement activities across all product development, production, distribution, use and disposal phases.

Energy Label

Space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device are subject to Energy labelling EU Regulation No. 811/2013 and Ecodesign EU Regulation No. 813/2013 requirements.
As of September 2019, the energy efficiency scale for seasonal space heating ranges from A+++ to D, with A+++ being the most efficient. The water heating energy efficiency scale for the declared load profile for combination heat pumps ranges from to A+ to F, with A+ being the most efficient.
The energy labels should provide minimum necessary information such as; supplier's name, product model code, the rated output under three European climates (average, colder and warmer) for medium- and/or low-temperature applications (55 °C and 35 °C), European map displaying the three temperature zones, the sound power level indoors and/or outdoors. In addition, just for combination heat pumps, the energy label should also include a pictogram showing to be able to work only during off-peak hours.

Energy Label

Heat pump combination heaters

Heat pump space heaters

Name of Manufacturer Space Heating
Energy efficiency class Highest: A+++ Lowest: D

Name of model Hot water

Name of Manufacturer
Space Heating

Energy efficiency class Highest: A+ Lowest: F

Name of model
Energy efficiency class in medium/low temperature applications 55°C/35°

Operating noise for indoor and outdoor
14

Nominal capacity in Climate Zones
Cold/Average/Warm In heating mode, the EU is divided into three climate zones for calculation and classification purposes. This is to enable calculation of the energy efficiency taking into consideration the actual regional ambient temperatures.

Off-peak hour pictogram

Operating noise for indoor and outdoor

F-Gas regulation

The EU aims to reduce the environmental impact of F-gases through the reduction of the CO2 equivalent consumption of HFCs (hydrofluorocarbons). EU regulation 517/2014 prescribes a phase-down of HFCs, where the quantities of HFCs that are placed on the market are gradually reduced through the allocation of quotas by the European Commission. The phase-down targets are expressed in CO2 equivalents (= kg x GWP - Global Warming Potential) and aim to reduce HFC

consumption by 79 % in 2030. For new installations of single split air conditioners with a refrigerant charge below 3 kg, the GWP limit is set at 750 starting in 2025. The regulation has been put into force to encourage the industry and its users to transition to refrigerants with a lower GWP. Samsung is accelerating the transition towards lower GWP refrigerants, such as R32, and will continue to invest in environmentally friendly alternatives.

% of baseline consumption allowed

EU phase-down targets

100 90 80 70 60 50 40 30 20 10
0

2016

2018

2020

2022

Baseline = the average HFC consumption between 2009 and 2012

2024

2026

2028

2030

Reduction comparison between 2015 and 2030

79 % reduction

R32 Refrigerant
R32 refrigerant contributes to meeting the F-gas regulation targets as described in EU regulation 517/2014. Air conditioners with R32 refrigerant have a Global Warming Potential (GWP) of 675, which is significantly lower than the GWP of R410A (2,088). While refrigerants are an essential part of today's air conditioners, R32 would have a 68 % lower environmental impact1 than R410A if leaked into the atmosphere. It has an Ozone Depletion Potential (ODP) of zero, a high refrigeration capacity and a high thermal conductivity; meaning a high efficiency and a reduction in charging volume. Samsung's single split Residential (RAC), Multi Split (FJM) and Commercial (CAC) product ranges up to 12 kW all feature R32 refrigerant.
1 Comparison between R410A and R32 GWP. Source: European Commission.

Global Warming Potential (GWP) 2088
675

Charge ratio

100 % 74 %

Effective tCO2eq. 500

R410A

R32

15

2088

76 %

Introduction

Introduction Introduction

WEEE: Electronic Waste
Samsung adheres to the WEEE (Waste Electrical and Electronic Equipment) Directive. This Directive applies the principles of extended producer responsibility. It stipulates the safe collection, treatment, recycling and environmentally sound disposal of all electrical and electronic equipment. By working with collective recycling schemes in each EU member state Samsung co-finances the take-back and recycling of electronic products.

Batteries
Samsung has been giving new life to used batteries by funding collection, treatment and recycling by local battery recycling organisations.
Packaging
Samsung works together with recycling schemes and governmental organisations to collect, separate and reuse all packaging materials at various points in the distribution chain. Many materials can be recycled into new products and recycling helps to save natural resources. Recycling packaging helps to reuse valuable raw materials and to reduce the overall impact on the environment.

16

17

Introduction Introduction

Certifications

Heat Pump KEYMARK Certificate
The Heat Pump KEYMARK is a voluntary, independent, European certification mark (ISO type 5 certification) for all heat pumps, combination heat pumps and hot water heaters (as covered by Ecodesign, EU Regulation 813/2013 and 814/2013). It is based on independent, third-party testing and demonstrates compliance with product requirements as set in the Heat Pump KEYMARK scheme rules and with efficiency requirements as set by Ecodesign. It is aimed at certifying the product performances declared by the manufacturers.
The Heat Pump KEYMARK scheme is owned by the European Committee for standardization (CEN). The certificates are granted by independent certification bodies to products fulfilling all requirements of the scheme.
Samsung's Eco Heating Systems and the ClimateHub range are certified with a Heat Pump KEYMARK. This certification is recognised in a number of European countries which include France, Germany, the United Kingdom, Slovakia and Czech Republic.

Eurovent Certificate

Eurovent is globally known for its quality mark `Eurovent Certified Performance' which certifies performance ratings of air-conditioning and refrigeration products according to European and international standards. The `Eurovent Certified Performance' mark indicates that the prescribed quality requirement has been fulfilled and should not require the need to be proven after the customer's decision and after the manufacturer's production process.
Eurovent is an accredited third-party certification body. It builds customer confidence by leveling the competitive playing field for all manufacturers and by increasing the integrity and accuracy of the industrial performance ratings. Thus providing trustworthy services to the entire ecosystem.
Samsung air conditioning products ranging from the Residential AirConditioning (RAC), Multi Split (FJM), Commercial Air Conditioning (CAC), Digital Variable Multi S (DVM S) and Eco Heating System (EHS) line-up in the `Air­to­Water' (A2W) heat pump category are all Eurovent certified.
To check the ongoing validity of the Eurovent certified products from Samsung, please visit: www.eurovent-certification.com

18

19

20

Product Line-up

Introduction EHS

21

EHS EHS

Line-up
ClimateHub

Outdoor Unit

Tank Integrated Hydro Unit

Type

w Power Model Name

Capacity

Tank Integrated Hydro Unit (Split)

200 L(1)
AE200RNWSEG/ EU

260 L(1)
AE260RNWSEG/ EU

260 L(3)
AE260RNWSGG/ EU

Tank Integrated Hydro Unit (Mono)

200 L(1)
AE200RNWMEG/ EU

260 L(1)
AE260RNWMEG/ EU

260 L(3)
AE260RNWMGG/ EU

Tank Integrated Hydro Unit (TDM Plus)

200 L(1)

260 L(1)

AE200TNWTEH/ EU

AE260TNWTEH/EU

R32

Mono 1

Outdoor

Unit

AE050RXYDEG/EU 5.0 kW AE080RXYDEG/EU 8.0 kW

·

·

·

AE120RXYDEG/EU 12.0 kW

·

·

AE160RXYDEG/EU 16.0 kW

·

·

3

AE080RXYDGG/EU 8.0 kW

·

AE120RXYDGG/EU 12.0 kW

·

AE160RXYDGG/EU 16.0 kW

·

Split 1

AE040RXEDEG/EU 4.0 kW

·

·

AE060RXEDEG/EU 6.0 kW

·

·

AE090RXEDEG/EU 9.0 kW

·

·

3

AE090RXEDGG/EU 9.0 kW

·

R410A TDM 1 Outdoor Plus Unit

AE044MXTPEH/EU 4.4 kW AE066MXTPEH/EU 6.6 kW

·

·

·

·

AE090MXTPEH/EU 9.0 kW

·

·

AE120MXTPEH/EU 12.0 kW

·

AE160MXTPEH/EU 16.0 kW

·

3

AE090MXTPGH/EU 9.0 kW

·

·

AE120MXTPGH/EU 12.0 kW

·

AE160MXTPGH/EU 16.0 kW

·

TDM Plus Indoor
NEW

Type Capacity

2.2 kW 2.8 kW 3.6 kW 5.6 kW 7.1 kW 9.0 kW

WindFreeTM Deluxe
· · · · ·

Optional Controller

v Slim Duct
· · · ·

MSP Duct
· ·

Console
· · · ·

Model
Model name Maximum connectible Indoor Units App Voice recognition Welcome Cooling/Heating Automation Add scene Energy monitoring Product dimensions (mm) W x H x D

MIM-H04EN
Wi-Fi Kit 2.0 16
SmartThings Bixby
Geofencing Customised control with a variety of execution rules
Easy control throughout customised user mode Individual energy monitoring up to 16 outdoor units
185 x 130 x 29

Model
Model name Screen size/type Intuitive user interface Operation Functions
Smart connectivity Languages MWR-WW10N
MWR-WW10JN NEW IN Q1'21
MWR-WW10KN NEW IN Q2'21
Product dimensions (mm) W x H x D

MWR-WW10*N
Touch Controller 4.3'' Color LCD display Dynamic navigation with simplified buttons Heating / Cooling/ Auto / DHW Smart Grid Ready / PV Ready / 2-zone Control / Energy consumption monitor / Energy saving SmartThings via optional Wi-Fi Kit 2.0
English, German, French, Italian, Spanish, Polish (EN, DE, FR, IT, ES, PL)
English, Portuguese, Dutch, Greek, Czech, Slovak (EN, PT, NL, EL, CS, SK)
English, Finnish, Swedish, Norwegian, Danish, Lithuanian (EN, FI, SV, NO, DA, LT) 120x120x19

22

23

EHS EHS

Line-up
EHS with Third Party DHW Tank
Mono with Third Party DHW Tank

w

Type

Power Model Name

Capacity

R32 Outdoor Unit

Mono 1

3

AE050RXYDEG/EU AE080RXYDEG/EU AE120RXYDEG/EU AE160RXYDEG/EU AE080RXYDGG/EU AE120RXYDGG/EU AE160RXYDGG/EU

5.0 kW 8.0 kW 12.0 kW 16.0 kW 8.0 kW 12.0 kW 16.0 kW

Outdoor Unit

Mono Control Kit
Mono MIM-E03CN
· · · · · · ·

DHW Tank (third party)

Split with Third Party DHW Tank

w

Type

Power Model Name

Capacity

R32

Split

1

Outdoor Unit

3

AE040RXEDEG/EU AE060RXEDEG/EU AE090RXEDEG/EU AE090RXEDGG/EU

4.0 kW 6.0 kW 9.0 kW 9.0 kW

R410A

Split

1

Outdoor Unit

3

AE120JXEDEH/EU AE160JXEDEH/EU AE120JXEDGH/EU AE160JXEDGH/EU

12.0 kW 16.0 kW 12.0 kW 16.0 kW

24

Outdoor Unit
Split(1) AE090RNYDEG/EU
· · · ·
AE160JNYDEH/EU
· ·

Wall-Mounted Hydro Unit
Wall-Mounted Hydro Unit

DHW Tank (third party)
Split(3) AE090RNYDGG/EU
·
AE160JNYDGH/EU
· ·

TDM Plus with Third Party DHW Tank
TDM Plus with Third Party DHW Tank

w

Type

Power Model Name

Capacity

R410A TDM Plus Split

1

Outdoor Unit

3

AE044MXTPEH/EU AE066MXTPEH/EU AE090MXTPEH/EU AE120MXTPEH/EU AE160MXTPEH/EU AE090MXTPGH/EU AE120MXTPGH/EU AE160MXTPGH/EU

4.4 kW 6.6 kW 9.0 kW 12.0 kW 16.0 kW 9.0 kW 12.0 kW 16.0 kW

Outdoor Unit

Wall-Mounted Hydro Unit

DHW Tank (third party)

AE090MNYDEH/EU

Split(1)

Wall-Mounted Hydro Unit

Split(3)

AE160MNYDEH/EU

AE090MNYDGH/EU

AE160MNYDGH/EU

· · ·
· ·
· · ·

25

EHS EHS

Selecting the right heating system
ClimateHub

Main Function Comfort Feature
Smart Install

A2W Cooling A2W Heating A2W Domestic Hot Water A2A Cooling Maximum Allowable Indoor unit Connections Colour Display Low Noise1 Outing Schedule / Holiday Mode Emergency Operation Wi-Fi Kit SmartThings Wired Remote Controller Zone Controller
4
Mixing Valve 3-Way Valve
4
2-Way Valve Thermostat Control PV Integrated Smart Grid Ready Energy Consumption Monitoring Set FSV with SD Card Smart Checking

Mono / Split
· · ·
· · · · · · ·2 · · · · · · · · · ·

TDM Plus
(R410A)
· · · ·
up to 7 Indoor unit
· · · · · · ·2 · · · · · · · · · ·

26

Third Party DHW Tank solutions

Mono
· · ·
· · · · · · ·2 ·3 · ·4 · · ·
·
·

Split

Split
(R410A)

TDM Plus
(R410A)

·

·

·

·

·

·

·

·

·

·

up to 7 Indoor unit

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·3

·3

·

·

·

·4

·4

·4

·

·

·

·

·

·

·

·

·

·

·

·

1 Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 2 Wired Remote Controller to be ordered separately. 3 In combination with an external room sensor. 4 Not provided by Samsung.
27

EHS EHS

Nomenclature

Indoor units

AE 260 R N W S E G

1

2

3

4

5

6

7

8

1 Classification

AE

2 Capacity

J

M 3 Year
R

T

4 Product Type

N

A/X
J L 5 Product Notation M W Y
D

P

6 Feature

M

S

T

E 7 Rating Voltage
G

G 8 Mode
H

EHS x1/10 kW (3 digits)
x Litre (3 digits) 2015 2017 2019 2020
Indoor Unit (NASA) RAC Wall-Mounted
Console LSP Duct MSP Duct Tank Integrated Hydro Unit Wall-Mounted Hydro Unit
Standard
Mono Split TDM Plus 1, 220~240 V, 50 Hz 3, 380~415 V, 50 Hz R32 Heat Pump R410A Heat Pump

Outdoor units

AE 090 R X E D E G

1

2

3

4

5

6

7

8

1 Classification

AE

2 Capacity

J

3 Year

M

R

4 Product Type

X

E

5 Product Notation

T

Y

D 6 Feature
P

E 7 Rating Voltage
G
G 8 Mode
H

EHS x1/10 kW (3 digits)
2015 2017 2019 Outdoor Unit (NASA) Split TDM Plus Mono
Standard
1, 220~240 V, 50 Hz 3, 380~415 V, 50 Hz
R32 Heat Pump R410A Heat Pump

28

29

ClimateHub Features

EHS EHS

Compact Design
The Samsung ClimateHub solution is built around a compact tank integrated hydro unit, with a large volume domestic hot water tank of either 200 L or 260 L. The compact and modular design makes for straightforward kitchen or utility room integration.
Smart Grid Ready and PV Enabled
A Smart Grid efficiently integrates the behaviour and actions of all the users connected to it. Smart Grid readiness enables users to benefit from an economically efficient and sustainable power supply. Thanks to the PV (Photovoltaic or `solar' energy) enabled feature, the system can be connected to solar panels, saving energy through renewable sources.1
1 The usage of the PV Enabled feature requires additional third party equipment to be installed.
Smooth Servicing
With a conveniently placed servicing window and intuitive servicing options available through the use of a Micro SD card or the Samsung S-Checker Mobile App, troubleshooting and start-up can be done easily from the front of the unit.1
1 Please refer to your direct Samsung contact person for more information about the S-Checker Mobile App.
30

Intuitive Control
Samsung's touch controller comes equipped with multiple language options and bright colour display ­ enabling temperature settings, energy monitoring, summer time setting and quick error monitoring.1
1 The image shows an application example and is for illustrative purposes only. Please always check latest information for understanding availability of language versions.

Quiet Operation
In order to meet increasingly strict sound level requirements, Samsung ClimateHub allows to reduce noise levels using the 4-Step Quiet Operation mode1. Subject to specific models and particular operation conditions, it is possible to achieve levels as low as 35 dB(A)2.
1 ClimateHub Mono and TDM Plus has a 3-Step Quiet Operation mode. 2 Sound pressure levels are subject to execution and operating conditions.

Smart Connectivity
The touch controller enables users to manage different temperature settings per zone, meaning high-temperature radiators and low-temperature floor heating can be utilised efficiently. With the optional Wi-Fi Kit, different aspects of the system, including controlling and monitoring up to 16 indoor units through the Samsung SmartThings App.1
1 A Wi-Fi connection and Samsung SmartThings application account are required. Wi-Fi Kit to be ordered separately. Requires iOS 10.0 or later & Android 5.0 or later.
31

EHS EHS

Comfortably cool. Surprisingly still.
Samsung introduces a completely new WindFreeTM wallmounted model for its EHS TDM Plus product range.
Equipped with WindFreeTM technology, the micro-holes spread fresh air gently and evenly to enhance indoor comfort for ultimate indoor climate convenience.

Step 1
The front panel opens, and Fast Cooling mode cools the room quickly from corner to corner.

Step 2
The set temperature is reached in Fast Cooling mode, and the front panel closes.

Step 3
WindFreeTM mode spreads fresh air uniformly through thousands of micro-holes.

WindFreeTM Cooling

Easy Control

Easy Installation

WindFreeTM technology enhances your indoor comfort by using thousands of micro-holes to disperse fresh air uniformly without any unpleasant blasts of cold wind.
In WindFreeTM mode, air is spread softly and silently, creating a `Still Air' environment1 that provides you
total well-being day and night.

Samsung WindFreeTM is designed to make life easier. It can be operated via wired or wireless controllers that feature advanced functions for a convenient control of indoor climates. Temperatures can also be managed remotely using the SmartThings App2.. Turning it on and off, selecting the cooling mode or scheduling its
operation is just one touch away.

The WindFreeTM Deluxe can be easily mounted through its snap-fit design and roller bracket. The installation process is simplified to fit in
effortlessly to the exact position. With an easy-to-remove front grill and a separate cover panel, installers can minimise product
damage and reduce service time.

1 ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers) defines "Still Air" as air currents at speeds below 0.15m/s which lacks the presence of cold drafts. 2 A Wi-Fi connection and Samsung SmartThings application account are required. Wi-Fi Kit to be ordered separately. Requires iOS 10.0 or later & Android 5.0 or later..

32

Wi-Fi Kit 2.0 ­ Mobile Remote Control and Monitoring Solution

You can remotely control and monitor up to 16 indoor units with ease by using the SmartThings App2.

Enhanced Convenience
The voice command feature is available through a smartphone with Bixby1. Temperatures can also be managed remotely anytime, and anywhere, using the SmartThings app2.

Personalised Climate Environment
Operates in your preferred mode according to the user settings. The geofencing functionality allows the room temperature to be automatically set at the desired level when the user approaches within a preset distance from the building. The Wi-Fi-Kit (optional) is mandatory to enable a multi-device experience interoperable with smart appliances.

Energy Usage Monitoring3
Energy usage can be monitored daily, weekly and monthly at a glance.

Provides ease of installation
Allows for easy setup possible for up to 16 indoor units.

1 App Voice Recognition: Bixby voice is an intelligent voice assistant that helps you use the device more conveniently.

1 Currently Voice control is supported in English (US, UK, Indian), Chinese, Korean, French, German, Italian, Spanish and Portuguese. 2 A Wi-Fi connection and Samsung SmartThings application account are required. Wi-Fi Kit to be ordered separately. Requires iOS 10.0 or later & Android 5.0 or later. 3 Current and daily, weekly or monthly energy usage of the outdoor unit is reference data calculated for information and reference purposes only.

Energy monitoring
Allows you to view your daily, weekly, and monthly energy usage at a glance

Energy service
Allows you to quickly check the energy usage of multiple devices in your home

Automation
Operates in your preferred mode according to the user settings

Welcome cooling/heating
Pre-cooling and pre-heating before your arrival at home

33

EHS Mono

Mono
34

Project: Atico en el Retiro (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Belén Imaz
35

Mono Mono

Specifications

ClimateHub Mono
· Integrated solution for heating and domestic hot water · Compact unit size with large water tank (200 L & 260 L) · Intuitive, colour screen touch controller in multiple languages · Energy monitoring through touch controller · Smooth servicing through the front-mounted service window

· PV and Smart Grid ready · 2-zone Control, suitable for floor heating and radiators · SCOP rating of A+++* · SmartThings compatible with optional Wi-Fi kit · Backup heater is included to ensure continuous heating

System
Tank Integrated Hydro Unit Outdoor Unit

Indoor Unit Outdoor Unit
Controller

Operation

Nominal Capacity

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

Power Input (Nominal)

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

COP (Nominal Heating) A7/W35¹ / A7/W55²

EER (Nominal Cooling) A35/W18¹

SCOP LWT 35°C/ 55°C

Seasonal Space Heating enr.efficiency s LWT 35°C/ 55°C

Seasonal Space Heating Eff. class * LWT 35°C/ 55°C
Current

MCA MFA

Water Flow Rate Leaving Water Temperature³

Low / Medium temperature
Heating

Cooling

Functions

Smart Grid Ready / PV Enabled

3-Step Quiet Mode

2-zone Control

Power Supply Water Tank Volume

Declared Load Profile Average water heating efficiency wh Average Energy Efficiency Class

Sound
Heater Piping Dimensions

Sound Pressure4
Sound Power Back-up heater Capacity Water Pipe (Space Heating) Water pipe (DHW) Net Weight

Heating Std Cooling Std Heating Std Default (Option) Inlet/ Outlet Inlet/ Outlet

Power Supply Compressor Base Heater Sound

Net Dimensions (WxHxD)
Type Capacity Sound Pressure4

Dimensions Refrigerant

Sound Power Net Weight Net Dimensions (WxHxD) Type Factory Charging

Heating Std Cooling Std Heating Std

Piping Operation

Water Pipe (Space Heating) Ambient Temperature

Inlet/ Outlet Heating Cooling DHW

kW kW kW kW W/W W/W W/W ETA%
-
A A l/min
  , #, V, Hz litres L/XL ETA% dB(A) dB(A) dB(A) kW , mm , mm kg mm , V, Hz kW dB(A) dB(A) dB(A) kg mm
tCOe kg , mm   

AE200RNWMEG/EU AE050RXYDEG/EU
MWR-WW10N

AE200RNWMEG/EU AE080RXYDEG/EU
MWR-WW10N

AE200RNWMEG/EU AE120RXYDEG/EU
MWR-WW10N

5.0/4.3 5.0
1.03/1.52 1.14
4.85/2.83 4.39
4.46/3.2
175/ 125

8.0/7.1 7.5
1.77/2.53 1.90
4.52/2.81 3.95
4.44/3.23
175/ 126

12.0/11.3 12.0
2.65/3.73 2.77
4.53/3.03 4.33
4.69/3.51
185/ 138

A+++ / A++
16.00 20.00
14.4/7.8
15~65 5~25
  
1, 2, 220~240 V, 50 Hz 200 L 115 A 26 26 40
2 (4/6) 28/28 22/22 130.0 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary
45 45 61 58.5 880 x 798 x 310
0.68 1.00 28/28 -25~35 10~46 -25~43

A+++ / A++
22.00 27.50
23.1/12.8
15~65 5~25
  
1, 2, 220~240 V, 50 Hz 200 L 115 A 26 26 40
2 (4/6) 28/28 22/22 130.0 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15
48 48 63 76.0 940 x 998 x 330 R32 (Fluorinated greenhouse gas, GWP=675) 0.78 1.15 28/28 -25~35 10~46 -25~43

A+++ / A++
28.00 35.00
34.6/20.4
15~65 5~25
  
1, 2, 220~240 V, 50 Hz 200 L 110 A 30 30 44
2 (4/6) 28/28 22/22 130.0 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15
50 50 64 110.0 940 x 1,420 x 330
1.49 2.20 28/28 -25~35 10~46 -25~43

36

Accessories

Touch Controller MWR-WW10N

Touch Controller MCM-A300N

DMS2.5 MIM-D01AN

Wi-Fi Kit MIM-H04EN

External Room Sensor MRW-TA

Backup Heater (4/6kW) MHC-*00FE

AE200RNWMEG/EU AE160RXYDEG/EU
MWR-WW10N
16.0/15.0 14.0
3.62/5.18 3.28
4.42/2.90 4.27
4.48/3.53
176/ 138
A+++ / A++
32.00 40.00
46.2/27.1
15~65 5~25
  
1, 2, 220~240 V, 50 Hz 200 L 110 A 30 30 44
2 (4/6) 28/28 22/22 130.0 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15
52 54 66 110.0 940 x 1,420 x 330
1.49 2.20 28/28 -25~35 10~46 -25~43

AE260RNWMEG/EU AE080RXYDEG/EU
MWR-WW10N

AE260RNWMEG/EU AE120RXYDEG/EU
MWR-WW10N

8.0/7.1 7.5
1.77/2.53 1.90
4.52/2.81 3.95
4.44/3.23
175/ 126

12.0/11.3 12.0
2.65/3.73 2.77
4.53/3.03 4.33
4.69/3.51
185/ 138

A+++ / A++

A+++ / A++

22.00 27.50

28.00 35.00

23.1/12.8

34.6/20.4

15~65

15~65

5~25

5~25













1, 2, 220~240 V, 50 Hz 260 XL 123

1, 2, 220~240 V, 50 Hz 260 XL 117

A

A

26

30

26

30

40

44

2 (4/6)

2 (4/6)

28/28

28/28

22/22

22/22

140.0

140.0

595 x 1,800 x 700

595 x 1,800 x 700

1, 220~240 V, 50 Hz

1, 220~240 V, 50 Hz

BLDC Twin Rotary 0.15 48

BLDC Twin Rotary 0.15 50

48

50

63

64

76.0

110.0

940 x 998 x 330

940 x 1,420 x 330

R32 (Fluorinated greenhouse gas, GWP=675)

0.78

1.49

1.15

2.20

28/28

28/28

-25~35

-25~35

10~46

10~46

-25~43

-25~43

AE260RNWMEG/EU AE160RXYDEG/EU
MWR-WW10N
16.0/15.0 14.0
3.62/5.18 3.28
4.42/2.90 4.27
4.48/3.53
176/ 138
A+++ / A++
32.00 40.00
46.2/27.1
15~65 5~25
  
1, 2, 220~240 V, 50 Hz 260 XL 117 A 30 30 44
2 (4/6) 28/28 22/22 140.0 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15
52 54 66 110.0 940 x 1,420 x 330
1.49 2.20 28/28 -25~35 10~46 -25~43

*A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++
1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB].
2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB].
365°C down to +10°C (max. 60°C down to -5°C)
4Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions.
37

Mono Mono

Specifications
ClimateHub Mono (Continued)

System
Tank Integrated Hydro Unit Outdoor Unit

Indoor Unit Outdoor Unit
Controller

Operation

Nominal Capacity

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

Power Input (Nominal)

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

COP (Nominal Heating) A7/W35¹ / A7/W55²

EER (Nominal Cooling) A35/W18¹

SCOP LWT 35°C/ 55°C

Seasonal Space Heating enr.efficiency s LWT 35°C/ 55°C

Seasonal Space Heating Eff. class * LWT 35°C/ 55°C

Current

MCA

MFA

Water Flow Rate

Low / Medium temperature

Leaving Water Temperature³ Heating

Cooling

Functions

Smart Grid Ready / PV Enabled

3-Step Quiet Mode

2-zone Control

Power Supply

Water Tank Volume

Declared Load Profile

Average water heating efficiency wh

Average Energy Efficiency Class

Sound

Sound Pressure4

Heating Std

Heater Piping

Sound Power Back-up heater Capacity Water Pipe (Space Heating) Water pipe (DHW)

Cooling Std Heating Std Default (Option) Inlet/ Outlet Inlet/ Outlet

Dimensions

Net Weight

Power Supply Compressor Base Heater Sound

Net Dimensions (WxHxD)
Type Capacity Sound Pressure4

Dimensions

Sound Power Net Weight

Heating Std Cooling Std Heating Std

Net Dimensions (WxHxD)

Refrigherant

Type Factory Charging

Piping Operation

Water Pipe (Space Heating) Ambient Temperature

Inlet/ Outlet Heating Cooling DHW

kW kW kW kW W/W W/W W/W ETA%
-
A A l/min
  , #, V, Hz litres L/XL ETA% dB(A) dB(A) dB(A) kW , mm , mm kg mm , V, Hz kW dB(A) dB(A) dB(A) kg mm
tCOe kg , mm   

AE260RNWMGG/EU AE080RXYDGG/EU
MWR-WW10N

AE260RNWMGG/EU AE120RXYDGG/EU
MWR-WW10N

AE260RNWMGG/EU AE160RXYDGG/EU
MWR-WW10N

8.0/7.1 7.5
1.77/2.53 1.90
4.52/2.81 3.95
4.44/3.23
175/ 126

12.0/11.3 12.0
2.65/3.73 2.77
4.53/3.03 4.33
4.69/3.51
185/ 138

16.0/15.0 14.0
3.62/5.18 3.28
4.42/2.90 4.27
4.48/3.53
176/ 138

A+++ / A++
10.00 16.10
23.1/12.8
15~65 5~25
  
3, 4, 380~415 V, 50 Hz 260 XL 123 A 26 26 40 6 28/28 22/22 140.0
595 x 1,800 x 700 3, 380~415 V, 50 Hz
BLDC Twin Rotary 0.15 48 48 63 75.0
940 x 998 x 330
0.78 1.15 28/28 -25~35 10~46 -25~43

A+++ / A++
10.00 16.10
34.6/20.4
15~65 5~25
  
3, 4, 380~415 V, 50 Hz 260 XL 117 A 30 30 44 6 28/28 22/22 140.0
595 x 1,800 x 700 3, 380~415 V, 50 Hz
BLDC Twin Rotary 0.15 50 50 64 111.0
940 x 1,420 x 330 R32 (Fluorinated greenhouse gas, GWP=675)
1.49 2.20 28/28 -25~35 10~46 -25~43

A+++ / A++
12.00 16.10
46.2/27.1
15~65 5~25
  
3, 4, 380~415 V, 50 Hz 260 XL 117 A 30 30 44 6 28/28 22/22 140.0
595 x 1,800 x 700 3, 380~415 V, 50 Hz
BLDC Twin Rotary 0.15 52 54 66 111.0
940 x 1,420 x 330
1.49 2.20 28/28 -25~35 10~46 -25~43

38

*A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++
1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB].
2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB].
365°C down to +10°C (max. 60°C down to -5°C)
4Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions.

Project: Atico en el Retiro (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Belén Imaz
39

Mono Mono

Specifications

Mono with Third Party DHW Tank
· Intuitive, colour screen touch controller in multiple languages · Energy monitoring through touch controller · PV and Smart Grid ready

· 2-zone Control, suitable for floor heating and radiators · SmartThings compatible with optional Wi-Fi kit

System Outdoor Unit

Operation
Functions Power Supply Compressor Base Heater Sound Dimensions Piping Refrigerant

Outdoor Unit Control Kit

Nominal Capacity

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

Power Input (Nominal)

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

COP (Nominal Heating) A7/W35¹ / A7/W55²

EER (Nominal Cooling) A35/W18¹

Seasonal space heating enr.efficiency s LWT 35°C/ 55°C

Seasonal space heating eff. class** LWT 35°C/ 55°C

Current

MCA

Leaving Water Temperature2

MFA Heating

Cooling

Smart Grid Ready / PV Enabled

3-Step Quiet Mode

2-zone Control

Type Capacity Sound Pressure4
Sound Power Net Weight Net Dimensions (WxHxD) Water Pipe Type Factory Charging

Heating Std Cooling Std Heating Std
Inlet/ Outlet

Operation

Ambient Temperature

Heating Cooling DHW

kW kW kW kW W/W W/W ETA%
-
A A   , V, Hz kW dB(A) dB(A) dB(A) kg mm , mm
tCOe kg   

AE050RXYDEG/EU MIM-E03CN

AE080RXYDEG/EU MIM-E03CN

AE120RXYDEG/EU MIM-E03CN

5.0/4.3 5.0
1.03/1.52 1.14
4.85/2.83 4.39
175/ 125

8.0/7.1 7.5
1.77/2.53 1.90
4.52/2.81 3.95
175/ 126

12.0/11.3 12.0
2.65/3.73 2.77
4.55/3.03 4.33
185/ 138

A+++ / A++
16.00 20.00 15~65 5~25
  
1, 220~240 V, 50 Hz BLDC Twin Rotary 45 45 61 58.5 880 x 798 x 310 25/ 25
0.68 1.00 -25~35 10~46 -25~43

A+++ / A++
22.00 27.50 15~65 5~25
  
1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15 48 48 63 76.0 940 x 998 x 330 25/ 25
R32 (Fluorinated greenhouse gas, GWP=675) 0.78 1.15
-25~35 10~46 -25~43

A+++ / A++
28.00 35.00 15~65 5~25
  
1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15 50 50 64 110.0 940 x 1,420 x 330 25/ 25
1.49 2.20 -25~35 10~46 -25~43

40

Accessories

Mono Control Kit MIM-E03CN

Touch Controller MCM-A300N

DMS2.5 MIM-D01AN

Wi-Fi Kit MIM-H04EN

External Room Sensor MRW-TA

AE160RXYDEG/EU MIM-E03CN
16.0/15.0 14.0
3.62/5.18 3.28
4.42/2.90 4.27
176/ 138
A+++ / A++
32.00 40.00 15~65 5~25
  
1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15 52 54 66 110.0 940 x 1,420 x 330 25/ 25
1.49 2.20 -25~35 10~46 -25~43

AE080RXYDGG/EU MIM-E03CN

AE120RXYDGG/EU MIM-E03CN

8.0/7.1 7.5
1.77/2.53 1.90
4.52/2.81 3.95
175/ 126

12.0/11.3 12.0
2.65/3.73 2.77
4.53/3.03 4.33
185/ 138

A+++ / A++

A+++ / A++

10.00

10.00

16.10 15~65

16.10 15~65

5~25

5~25













3, 380~415 V, 50 Hz

3, 380~415 V, 50 Hz

BLDC Twin Rotary 0.15 48

BLDC Twin Rotary 0.15 50

48

50

63

64

75.0

111.0

940 x 998 x 330

940 x 1,420 x 330

25/ 25

25/ 25

R32 (Fluorinated greenhouse gas, GWP=675)

0.78

1.49

1.15

2.20

-25~35

-25~35

10~46

10~46

-25~43

-25~43

AE160RXYDGG/EU MIM-E03CN
16.0/15.0 14.0
3.62/5.18 3.28
4.42/2.90 4.27
176/ 138
A+++ / A++
12.00 16.10 15~65 5~25
  
3, 380~415 V, 50 Hz BLDC Twin Rotary 0.15 52 54 66 111.0 940 x 1,420 x 330 25/ 25
1.49 2.20 -25~35 10~46 -25~43

*A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++
1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB].
2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB].
365°C down to +10°C (max. 60°C down to -5°C)
4Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions.
41

Dimensional Drawings
Mono Tank Integrated Hydro Unit
AE200/260RNW**G/EU

Mono Outdoor
AE050RXYDEG/EU
880



310

Mono

364 798

Mono

NO
1 2 3 4 5 6 7 8 9
42

Name
Space heating Inlet Space heating Outlet
DHW Inlet Secondary water return
DHW Outlet Heat Pump In Heat Pump Out
T/P v/v Drain Holes

AE200RNWMEG/EU

Description

AE260RNWM*G/EU

ø28

ø28

ø28

ø28

ø22

ø22

N/A

ø22

ø22

ø22

ø28

ø28

ø28

ø28

Female PT 1/2"

Female PT 1/2"

(Option) Connect with the provided drain plug

 

497 227

NO
1 2 3

Name

Description

Water Pipe(Out)

BSPP male 1"

Water Pipe(In)

BSPP male 1"

Power & Communication Wiring Conduit Holes

364
43

Dimensional Drawings
Mono Outdoor
AE080RXYD*G/EU
514 245

Mono Outdoor
AE120/160RXYD*G/EU

Mono Mono

940

385

 

998

NO
1 2 3

Name

Description

Water Pipe(Out)

BSPP male 1"

Water Pipe(In)

BSPP male 1"

Power & Communication Wiring Conduit Holes

44

330

360 385







NO
1 2 3

Name

Description

Water Pipe(Out)

BSPP male 1"

Water Pipe(In)

BSPP male 1"

Power & Communication Wiring Conduit Holes

45

Mono Mono

Dimensional Drawings
Mono Control Kit
MIM-E03CN

NO 1

Name Conduit Holes for Wiring (Rubber)

46

Project: Casa L (Spain) Project Architecture: ÁBATON
Interior Design: BATAVIA Photography: Carlos Muntadas
47

Mono Split

Split
48

Project: Casa L (Spain) Project Architecture: ÁBATON
Interior Design: BATAVIA Photography: Carlos Muntadas
49

Split Split

Specifications
ClimateHub Split
· Integrated solution for heating and domestic hot water · 4-step quiet operation mode (down to 35 db(A)*) · Compact unit size with large water tank (200 L & 260 L)

System
Tank Integrated Hydro Unit Outdoor Unit
50

Indoor Unit Outdoor Unit
Controller

Operation

Nominal Capacity

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

Power Input (Nominal)

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

COP (Nominal Heating) A7/W35¹ / A7/W55²

EER (Nominal Cooling) A35/W18¹

SCOP LWT 35°C/ 55°C

Seasonal space heating enr.efficiency s LWT 35°C/ 55°C

Average Seasonal space heating eff. class ** LWT 35°C/ 55°C

Current

MCA

MFA

Leaving Water Temperature³

Heating Cooling

Functions

Smart Grid Ready / PV Enabled

4-Step Quiet Mode

2-zone Control

Power Supply

Water Tank Volume

Declared Load Profile

Average water heating efficiency wh

Average Energy Efficiency Class

kW kW kW kW W/W W/W W/W ETA%
-
A A   , #, V, Hz litres L/XL ETA%

Heater Sound
Piping Dimensions Power Supply Compressor Base Heater Sound
Dimensions
Piping
Operation

Back-up heater Capacity

Default (Option) kW

Sound Pressure4

Heating Std

dB(A)

Cooling Std

dB(A)

Sound Power

Heating Std

dB(A)

Water pipe (Space Heating) Inlet/Outlet

, mm

Water pipe (DHW)

Inlet/Outlet

, mm

Net Weight

kg

Net Dimensions (WxHxD)

mm

, V, Hz

Type

-

Capacity

kW

Sound Pressure4

Heating Std

dB(A)

Cooling Std

dB(A)

Night Mode

dB(A)

Sound Power

Heating Std

dB(A)

Net Weight

kg

Net Dimensions (WxHxD)

mm

Refrigerant

Type

-

Factory Charging

tCOe

kg

Piping Connections

Liquid Pipe

, mm (inch)

Gas Pipe

, mm (inch)

Piping length (ODU-IDU)5 Max.[Equiv.]

m

Level difference (IDU-IDU)5 Max.

m

Ambient Temperature

Heating



Cooling



DHW



AE200RNWSEG/EU AE040RXEDEG/EU
MWR-WW10N

AE200RNWSEG/EU AE060RXEDEG/EU
MWR-WW10N

AE200RNWSEG/EU AE090RXEDEG/EU
MWR-WW10N

4.4/3.9 5.0
0.85/1.32 1.09
5.20/2.95 4.59
4.58/3.25
180/ 127

6.0/5.2 6.5
1.22/1.81 1.47
4.92/2.87 4.42
4.58/3.31
180/ 129

9.0/8.0 8.7
1.87/2.73 2.11
4.81/2.93 4.12
4.45/3.24
175/ 127

A+++ / A++
16.00 20.00 15~65 5~25
  
1, 2, 220~240 V, 50 Hz 200 L 120 A+
2 (4/6) 26 26 40
28/28 22/22 136 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary
44 46 <35 58 46.5 880 x 638 x 310
0.81 1.2 6.35 (1/4") 15.88 (5/8") 30.00 20.00 -25~35 10~46 -25~43

A+++ / A++
16.00 20.00 15~65 5~25
  
1, 2, 220~240 V, 50 Hz 200 L 120 A+
2 (4/6) 26 26 40
28/28 22/22 136 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary
47 47 35 60 46.5 880 x 638 x 310 R32 (Fluorinated greenhouse gas, GWP=675) 0.81 1.2 6.35 (1/4") 15.88 (5/8") 30.00 20.00 -25~35 10~46 -25~43

A+++ / A++
22.00 27.50 15~65 5~25
  
1, 2, 220~240 V, 50 Hz 200 L 119 A+
2 (4/6) 26 26 40
28/28 22/22 136 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15
49 49 35 64 73.0 940 x 998 x 330
0.95 1.4 6.35 (1/4") 15.88 (5/8") 35.00 20.00 -25~35 10~46 -25~43

Accessories

Touch Controller MWR-WW10N

Touch Controller MCM-A300N

DMS2.5 MIM-D01AN

Wi-Fi Kit MIM-H04EN

External Room Sensor MRW-TA

Backup Heater (4/6kW) MHC-*00FE

AE260RNWSEG/EU AE040RXEDEG/EU
MWR-WW10N
4.4/3.9 5.0
0.85/1.32 1.09
5.20/2.95 4.59
4.58/3.25
180/ 127
A+++ / A++
16.00 20.00 15~65 5~25
  
1, 2, 220~240 V, 50 Hz 260 XL 123 A+
2 (4/6) 26 26 40
28/28 22/22 146.0 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary
44 46 <35 58 46.5 880 x 638 x 310
0.81 1.2 6.35 (1/4") 15.88 (5/8") 30.00 20.00 -25~35 10~46 -25~43

AE260RNWSEG/EU AE060RXEDEG/EU
MWR-WW10N

AE260RNWSEG/EU AE090RXEDEG/EU
MWR-WW10N

6.0/5.2 6.5
1.22/1.81 1.47
4.92/2.87 4.42
4.58/3.31
180/ 129

9.0/8.0 8.7
1.87/2.73 2.11
4.81/2.93 4.12
4.45/3.24
175/ 127

A+++ / A++

A+++ / A++

16.00

22.00

20.00

27.50

15~65

15~65

5~25

5~25













1, 2, 220~240 V, 50 Hz

1, 2, 220~240 V, 50 Hz

260

260

XL

XL

123

123

A+

A+

2 (4/6)

2 (4/6)

26

26

26

26

40

40

28/28

28/28

22/22

22/22

146.0

146.0

595 x 1,800 x 700

595 x 1,800 x 700

1, 220~240 V, 50 Hz

1, 220~240 V, 50 Hz

BLDC Twin Rotary

BLDC Twin Rotary

-

0.15

47

49

47

49

35

35

60

64

46.5

73.0

880 x 638 x 310

940 x 998 x 330

R32 (Fluorinated greenhouse gas, GWP=675)

0.81

0.95

1.2

1.4

6.35 (1/4")

6.35 (1/4")

15.88 (5/8")

15.88 (5/8")

30.00

35.00

20.00

20.00

-25~35

-25~35

10~46

10~46

-25~43

-25~43

AE260RNWSGG/EU AE090RXEDGG/EU
MWR-WW10N
9.0/8.0 8.7
1.87/2.73 2.11
4.81/2.93 4.12
4.45/3.24
175/ 127
A+++ / A++
10.00 16.10 15~65 5~25
  
3, 4, 380~415 V, 50 Hz 260 XL 123 A+ 6 26 26 40 28/28 22/22 146.0
595 x 1,800 x 700 3, 380~415 V, 50 Hz
BLDC Twin Rotary 0.15 49 49 35 64 72.0
940 x 998 x 330
0.95 1.4 6.35 (1/4") 15.88 (5/8") 35.00 20.00 -25~35 10~46 -25~43

*35dB(A) is only applicable for 6kW and 9kW outdoor units down to +4°C stated in 3 m distance in an anechoic environment.
**A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++
1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB].
2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB].
365°C down to +10°C (max. 60°C down to -5°C)
4Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions.
5 ODU : Outdoor Unit, IDU : Indoor Unit
51

Split Split

Specifications

Split with Third Party DHW Tank

· Connectable with R32 Split Outdoor Unit in combination of third party Tank · Competible with thermostats, solar panels and back-up boilers · Intuitive, colour screen touch controller in multiple languages · Energy monitoring through touch controller · PV and Smart Grid ready

· 2-zone Control, suitable for floor heating and radiators · SmartThings compatible with optional Wi-Fi kit

System
Wall-Mounted Hydro Unit Outdoor unit

Indoor Unit Outdoor Unit

Operation

Nominal Capacity

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

Power Input (Nominal)

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

COP (Nominal Heating) A7/W35¹

EER (Nominal Cooling) A35/W18¹

Seasonal space heating enr.efficiency s LWT 35°C/ 55°C

Seasonal Space Heating Eff. Class LWT 35°C/ 55°C

Current

MCA

MFA

Leaving Water Temperature2

Heating

Cooling

Functions

Smart Grid Ready / PV Enabled

4-Step Quiet Mode

2-zone Control

Power Supply

Heater

Back-up heater Capacity

Default (Option)

Sound

Sound Pressure³

Heating Std

Cooling Std

Sound Power

Heating Std

Dimensions Net Weight

Net Dimensions (WxHxD)

Piping

Water pipe

Inlet/Outlet

Compressor Type

Base Heater Capacity

Sound

Sound Pressure3

Heating Std

Cooling Std

Sound Power

Heating Std

Dimensions Net Weight

Net Dimensions (WxHxD)

Refrigerant Type

Factory Charging

Piping

Piping Connections

Operation

Piping length (ODU-IDU)4 Level difference (IDU-IDU)4 Chargeless Length Ambient Temperature

Liquid Pipe Gas Pipe Max.[Equiv.] Max.
Heating Cooling DHW

kW kW kW kW W/W W/W ETA%
-
A A   , V, Hz kW dB(A) dB(A) dB(A) kg mm , inch kW dB(A) dB(A) dB(A) kg mm
tCOe kg , mm (inch) , mm (inch) m m , mm   

AE090RNYDEG/EU AE040RXEDEG/EU

AE090RNYDEG/EU AE060RXEDEG/EU

AE090RNYDEG/EU AE090RXEDEG/EU

4.4/3.9 5.0
0.85/1.32 1.09
5.20/2.95 4.59
180/ 127

6.0/5.2 6.5
1.22/1.81 1.47
4.92/2.87 4.42
180/ 129

9.0/8.0 8.7
1.87/2.73 2.11
4.81/2.93 4.12
175/ 127

A+++ / A++
16.00 20.00 15~65 5~25



1, 2, 220~240 V, 50 Hz 4 26 26 40
45,0 510 x 850 x 315
1+1/4'' BLDC Twin Rotary
44 46 58 46.5 880 x 638 x 310

A+++ / A++
16.00 20.00 15~65 5~25



1, 2, 220~240 V, 50 Hz 4 26 26 40
45,0 510 x 850 x 315
1+1/4'' BLDC Twin Rotary
47 47 60 46.5 880 x 638 x 310

A+++ / A++
22.00 27.50 15~65 5~25



1, 2, 220~240 V, 50 Hz 4 26 26 40
45,0 510 x 850 x 315
1+1/4'' BLDC Twin Rotary
0.15 49 49 64 73.0 940 x 998 x 330

R32 (Fluorinated greenhouse gas, GWP=675)

1.2 0.81 6.35 (1/4'') 15.88 (5/8'') 30 20 15 -25~35 10~46 -25~43

1.2 0.81 6.35 (1/4'') 15.88 (5/8'') 30 20 15 -25~35 10~46 -25~43

1.4 0.95 6.35 (1/4'') 15.88 (5/8'') 35 20 15 -25~35 10~46 -25~43

52

Accessories

Touch Controller (included) MWR-WW10N

Touch Controller MCM-A300N

DMS2.5 MIM-D01AN

Wi-Fi Kit MIM-H04EN

External Room Sensor MRW-TA

AE090RNYDGG/EU
AE090RXEDGG/EU
9.0/8.0 8.7
1.87/2.73 2.11
4.81/2.93 4.12
175/127
A+++ / A++
10.00 16.10 15~65 5~25



3, 2, 380~415 V, 50 Hz 6 26 26 40
46.5 510 x 850 x 315
1+1/4'' BLDC Twin Rotary
0.15 49 49 64 72.0 940 x 998 x 330 R32 (Fluorinated greenhouse gas, GWP=675) 1.4 0.95 6.35 (1/4'') 15.88 (5/8'') 35 20 15 -25~35 10~46 -25~43

**A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++
1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB].
2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB].
3Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions.
4 ODU : Outdoor Unit, IDU : Indoor Unit
53

Specifications
Split with Third Party DHW Tank (R410A)
· Connectable with R410A Split Outdoor Unit in combination of third party Tank · Competible with room thermostats, solar pumps, 2- or 3-way valves and back-up boilers

Accessories

EHS Controller (included) MWR-WW00N

Touch Controller MCM-A300N

DMS2.5 MIM-D01AN

Wi-Fi Kit MIM-H04EN

External Room Sensor MRW-TA

Split Split

System
Wall-Mounted Hydro Unit Outdoor unit

Indoor Unit Outdoor Unit

Operation

Nominal Capacity

Power Input (Nominal)

COP (Nominal Heating) A7/W35¹
EER (Nominal Cooling) A35/W18¹
Seasonal space heating enr.efficiency s LWT 35°C/ 55°C
Seasonal Space Heating Eff. Class LWT 35°C/ 55°C
Current

Leaving Water Temperature

Functions

Smart Grid Ready/PV Enabled

3-Step Quiet Mode

2-zone Control²

Power Supply

Heater

Capacity

Sound

Sound Pressure3

Piping Dimensions
Compressor Base Heater Sound

Sound Power Water pipe Net Weight Net Dimensions (WxHxD) Type Capacity Sound Pressure3

Dimensions Refrigerant

Sound Power Net Weight Net Dimensions (WxHxD) Type

Heating A7/W35¹ Cooling A35/W18¹ Heating A7/W35¹ Cooling A35/W18¹
MCA MFA Heating Cooling
Heating Std Cooling Std Heating Std Inlet/Outlet
Heating Std Cooling Std Heating Std

Factory Charging

Piping

Piping Connections

Operation

Piping length (ODU-IDU)4 Level difference (IDU-IDU)4 Chargeless Length Ambient Temperature

Liquid Pipe
Gas Pipe
Max.[Equiv.] Max.
Heating Cooling DHW

kW kW kW kW W/W W/W ETA%
-
A A   , V, Hz kW dB(A) dB(A) dB(A) , inch kg mm kW dB(A) dB(A) dB(A) kg mm
tCOe kg , mm (inch) , mm (inch) m m , mm   

AE160JNYDEH/EU AE120JXEDEH/EU

AE160JNYDGH/EU AE120JXEDGH/EU

AE160JNYDEH/EU AE160JXEDEH/EU

12.0 12.0 2.59 3.10 4.63 3.87
184/ 107

12.0 12.0 2.59 3.10 4.63 3.87
184/ 107

16.0 15.0 3.76 4.14 4.26 3.62
173/ 115

A+++ / A+

A+++ / A+

A++ / A+

28.00 35.00 25~55 5~25
-


1, 2, 220~240 V, 50 Hz 6 33 33 47
1+1/4'' 45.0 510 x 850 x 315 BLDC Twin Rotary 0.15 50 50 64 100.0 940 x 1,420 x 330

10.00 16.10 25~55 5~25
-


3, 2, 380~415 V, 50 Hz 6 33 33 47
1+1/4'' 46.5 510 x 850 x 315 BLDC Twin Rotary 0.15 50 50 64 101.5 940 x 1,420 x 330

32.00 37.50 25~55 5~25
-


1, 2, 220~240 V, 50 Hz 6 33 33 47
1+1/4'' 45.0 510 x 850 x 315 BLDC Twin Rotary 0.15 52 54 66 100.0 940 x 1,420 x 330

R410A (Fluorinated greenhouse gas, GWP=2,088)

6.22

6.22

6.22

2.98

2.98

2.98

9.52 (3/8'')

9.52 (3/8'')

9.52 (3/8'')

15.88 (5/8'')
50 30 15 -25~35 10~46 -25~43

15.88 (5/8'')
50 30 15 -25~35 10~46 -25~43

15.88 (5/8'')
50 30 15 -25~35 10~46 -25~43

AE160JNYDGH/EU AE160JXEDGH/EU
16.0 15.0 3.76 4.14 4.26 3.62
173/ 115
A++ / A+
12.00 16.10 25~55 5~25
-
 
3, 2, 380~415 V, 50 Hz 6 33 33 47
1+1/4'' 46.5 510 x 850 x 315 BLDC Twin Rotary 0.15 52 54 66 101.5 940 x 1,420 x 330 R410A (Fluorinated greenhouse gas, GWP=2,088) 6.22 2.98
9.52 (3/8'')
15.88 (5/8'')
50 30 15 -25~35 10~46 -25~43

54

1 A2W Conditions : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB].
2 Not provided by Samsung.
3 Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions.
4 ODU: Outdoor Unit, IDU: Indoor Unit
55

Dimensional Drawings
Split Tank Integrated Hydro Unit
AE200/260RNW**G/EU

Split Outdoor
AE040/060RXEDEG/EU

Split Split

NO
1 2 3 4 5 6 7 8 9
56

Name
Space heating Inlet Space heating Outlet
DHW Inlet Secondary water return
DHW Outlet Refrigerant liquid pipe
Refrigerant gas pipe T/P v/v
Drain Holes

AE200RNWSEG/EU

Description

AE260RNWS*G/EU

Ø28

Ø28

Ø28

Ø28

Ø22

Ø22

N/A

Ø22

Ø22

Ø22

Ø9.52

Ø9.52

Ø15.88

Ø15.88

Female PT 1/2"

Female PT 1/2"

(Option) Connect with the provided drain plug

NO
1 2 3

Name
Refrigerant liquid pipe Refrigerant gas pipe Drain holes

Description 6.35(1/4) 15.88(5/8) Connect with the provided drain plug.
57

Split

Dimensional Drawings
Split Outdoor
AE090RXED*G/EU

NO
1 2 3 4 5 6

Name
Refrigerant gas pipe Refrigerant liquid pipe Piping intake knockout hole Power wiring conduit Communication wiring conduit
Drain Hole

58

Description
6.35(1/4) 15.88(5/8) Front / Side / Rear / Bottom Front / Side / Rear , 34 [1-3/8] Front / Side / Rear , 22 [7/8] Connect with the provided drain plug

Split Outdoor
AE120/160JXED*H/EU

12mm

330

943

940

300

1420

655

3-TOP

621





NO
1 2 3 4


Name Refrigerant gas pipe Refrigerant liquid pipe
Drain Hole Power wiring conduit

Description
 15.88  9.52 Connect with the provided drain plug
N/A

59

570 1107
Split

Split Split

Dimensional Drawings
Split Wall-Mounted Hydro Unit
AE090RNYD*G/EU, AE160JNYD*H/EU

NO 1 2 3 4
60

Name
Refrigerant gas pipe Refrigerant liquid pipe Water pipe inlet/outlet Drain Hose Connector

Project: Atico en el Retiro (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Belén Imaz
61

62

TDM Plus

Split TDM Plus

63

TDM Plus TDM Plus

Specifications

ClimateHub TDM Plus (R410A)
· 'All in one' air-to-water and air-to-air system · PV and Smart Grid ready · Compact unit size with large water tank (200L & 260L) · 2-zone control, suitable for floor heating and radiators · Intuitive, colour screen touch controller in multiple languages

· SCOP rating of A+++** · Energy monitoring through touch controller · SmartThings compatible with optional Wi-Fi kit · Smooth servicing through the front-mounted service window · Backup heater is included to ensure continuous heating

System
Tank Integrated Hydro Unit Outdoor Unit

Indoor Unit Outdoor Unit
Controller

Operation

Nominal Capacity

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

Power Input (Nominal)

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

COP (Nominal Heating) A7/W35¹ / A7/W55²

EER (Nominal Cooling) A35/W18¹

SCOP LWT 35°C/ 55°C

Seasonal space heating enr.efficiency s LWT 35°C/ 55°C

Average Seasonal space heating eff. class ** LWT 35°C/ 55°C

Current

MCA

MFA

Maximum allowable IDU5 connections (Hydro A2W unit not included)

Max. number of IDU5 Total capacity Min. (Cooling) Total capacity Min. (Cooling)

Leaving Water Temperature³ Heating

Cooling

Functions

Smart Grid Ready / PV Enabled

3-Step Quiet Mode

2-zone Control

Power Supply

Water Tank Volume

Declared Load Profile

Average water heating efficiency wh

Average Energy Efficiency Class

Heater Sound
Piping Dimensions
Power Supply Compressor Base Heater Sound
Dimensions
Refrigerant

Back-up heater Capacity Sound Pressure4
Sound Power Water pipe (Space Heating) Net Weight Net Dimensions (WxHxD)

Default (Option) Heating Std Cooling Std Heating Std Inlet/Outlet

Type Capacity Sound Pressure4
Sound Power Net Weight Net Dimensions (WxHxD) Type Factory Charging

Heating Std Cooling Std Heating Std

Piping Operation

Piping Connections
Piping length (ODU-IDU)5 Level difference (IDU-IDU)5 Chargeless length Ambient Temperature A2W
Ambient Temperature A2A

Liquid Pipe Gas Pipe Max.[Equiv.] Max.
Heating Cooling DHW Heating Cooling

kW kW kW kW W/W W/W W/W ETA% -
A A EA kW kW   , #, V, Hz litres L/XL ETA%
kW dB(A) dB(A) dB(A) , inch kg mm , V, Hz kW dB(A) dB(A) dB(A) kg mm Type tCOe kg , mm (inch) , mm (inch) m m m     

64

AE200TNWTEH/EU AE044MXTPEH/EU
MWR-WW10N

AE200TNWTEH/EU AE066MXTPEH/EU
MWR-WW10N

4.4/ 3.8 5.1
0.93/ 1.37 1.03
4.73/ 2.80 4.95
4.41/ 2.83 173/ 110

6.6/ 4.8 6.7
1.47/ 1.85 1.48
4.49/ 2.59 4.53
4.41/ 2.96 173/ 115

A++ / A+

A++ / A+

18.00 25.00
2 2.20 4.40 15~55 5~25

20.00 25.00
3 3.30 6.60 15~55 5~25













1, 2, 220~240 V, 50 Hz 200 L 115

1, 2, 220~240 V, 50 Hz 200 L 115

A+

A+

2 (4/6)

2 (4/6)

29

29

29

29

43

43

1+1/4''

1+1/4''

137

137

595 x 1,800 x 700

595 x 1,800 x 700

1, 2, 220~240 V, 50 Hz

1, 2, 220~240 V, 50 Hz

Rotary Comp

Rotary Comp

-

-

47

48

46

47

65

67

61.0

61.0

880 x 793 x 310

880 x 793 x 310

R410A (Fluorinated greenhouse gas, GWP=2,088)

5.43

5.43

2.6

2.6

9.52 (3/8'')

9.52 (3/8'')

15.88 (5/8'')

15.88 (5/8'')

30

30

20

20

10

10

-25~35

-25~35

10~46

10~46

-25~43

-25~43

-25~24

-25~24

10~46

10~46

Accessories

Touch Controller MWR-WW10N

Touch Controller MCM-A300N

DMS2.5 MIM-D01AN

Wi-Fi Kit MIM-H04EN

External Room Sensor MRW-TA

Backup Heater (4/6kW) MHC-*00FE

AE200TNWTEH/EU
AE090MXTPEH/EU
MWR-WW10N
9.0/ 7.7 8.0
2.12/ 2.82 1.85
4.25/ 2.72 4.32
4.42/ 3.01 174/ 117 A++ / A+
22.00 27.50
4 4.50 9.00 15~55 5~25



1, 2, 220~240 V, 50 Hz 200 L 115 A+
2 (4/6) 29 29 43
1+1/4'' 137
595 x 1,800 x 700 1, 2, 220~240 V, 50 Hz
Rotary Comp 51 50 69
74.0 940 x 998 x 330
5.01 2.4 9.52 (3/8'') 15.88 (5/8'') 30 20 10 -25~35 10~46 -25~43 -25~24 10~46

AE200TNWTEH/EU AE090MXTPGH/EU
MWR-WW10N

AE260TNWTEH/EU AE044MXTPEH/EU
MWR-WW10N

9.0/ 7.7 8.0
2.12/ 2.82 1.86
4.25/ 2.69 4.30
4.44/ 2.86 175/ 111

4.4/ 3.8 5.1
0.93/ 1.37 1.03
4.73/ 2.80 4.95
4.41/ 2.83 173/ 110

A+++ / A+

A++ / A+

10.00 16.10
4 4.50 9.00 15~55 5~25

18.00 25.00
2 2.20 4.40 15~55 5~25













1, 2, 220~240 V, 50 Hz 200 L 115

1, 2, 220~240 V, 50 Hz 260 XL 105

A+

A

2 (4/6)

2 (4/6)

29

29

29

29

43

43

1+1/4''

1+1/4''

137

147

595 x 1,800 x 700

595 x 1,800 x 700

3, 4, 380~415 V, 50 Hz

1, 2, 220~240 V, 50 Hz

Rotary Comp

Rotary Comp

-

-

51

47

50

46

69

65

76.0

61.0

940 x 998 x 330

880 x 793 x 310

R410A (Fluorinated greenhouse gas, GWP=2,088)

5.01

5.43

2.4

2.6

9.52 (3/8'')

9.52 (3/8'')

15.88 (5/8'')

15.88 (5/8'')

30

30

20

20

10

10

-25~35

-25~35

10~46

10~46

-25~43

-25~43

-25~24

-25~24

10~46

10~46

AE260TNWTEH/EU
AE066MXTPEH/EU
MWR-WW10N
6.6/ 4.8 6.7
1.47/ 1.85 1.48
4.49/ 2.59 4.53
4.41/ 2.96 173/ 115 A++ / A+
20.00 25.00
3 3.30 6.60 15~55 5~25



1, 2, 220~240 V, 50 Hz 260 XL 105 A
2 (4/6) 29 29 43
1+1/4'' 147
595 x 1,800 x 700 1, 2, 220~240 V, 50 Hz
Rotary Comp 48 47 67
61.0 880 x 793 x 310
5.43 2.6 9.52 (3/8'') 15.88 (5/8'') 30 20 10 -25~35 10~46 -25~43 -25~24 10~46

*35dB(A) is only applicable for 6kW and 9kW outdoor units down to +4°C stated in 3 m distance in an anechoic environment.
**A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++
1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB].
2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB].
365°C down to +10°C (max. 60°C down to -5°C)
4Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions.
5 ODU : Outdoor Unit, IDU : Indoor Unit
65

TDM Plus TDM Plus

Specifications
ClimateHub TDM Plus (R410A) (Continued)

System
Tank Integrated Hydro Unit Outdoor Unit

Indoor Unit Outdoor Unit
Controller

Operation

Nominal Capacity

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

Power Input (Nominal)

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

COP (Nominal Heating) A7/W35¹ / A7/W55²

EER (Nominal Cooling) A35/W18¹

SCOP LWT 35°C/ 55°C

Seasonal space heating enr.efficiency s LWT 35°C/ 55°C

Average Seasonal space heating eff. class ** LWT 35°C/ 55°C

Current
Maximum allowable IDU5 connections (Hydro A2Wunit not included) Leaving Water Temperature³

MCA MFA Max. number of IDU5 Total capacity Min. (Cooling) Total capacity Min. (Cooling) Heating Cooling

Functions

Smart Grid Ready / PV Enabled

3-Step Quiet Mode

2-zone Control

Power Supply

Water Tank Volume

Declared Load Profile

Average water heating efficiency wh

Average Energy Efficiency Class

Heater Sound
Piping Dimensions
Power Supply Compressor Base Heater Sound
Dimensions
Refrigerant

Back-up heater Capacity Sound Pressure4
Sound Power Water pipe (Space Heating) Net Weight Net Dimensions (WxHxD)

Default (Option) Heating Std Cooling Std Heating Std Inlet/Outlet

Type Capacity Sound Pressure4
Sound Power Net Weight Net Dimensions (WxHxD) Type Factory Charging

Heating Std Cooling Std Heating Std

Piping Operation

Piping Connections
Piping length (ODU-IDU)5 Level difference (IDU-IDU)5 Chargeless length Ambient Temperature A2W
Ambient Temperature A2A

Liquid Pipe Gas Pipe Max.[Equiv.] Max.
Heating Cooling DHW Heating Cooling

kW kW kW kW W/W W/W W/W ETA% -
A A EA kW kW   , #, V, Hz litres L/XL ETA% -
kW dB(A) dB(A) dB(A) , inch kg mm , V, Hz kW dB(A) dB(A) dB(A) kg mm Type tCOe kg , mm (inch) , mm (inch) m m m     

66

AE260TNWTEH/EU AE090MXTPEH/EU
MWR-WW10N

AE260TNWTEH/EU AE120MXTPEH/EU
MWR-WW10N

9.0/ 7.7 8.0
2.12/ 2.82 1.85
4.25/ 2.72 4.32
4.42/ 3.01 174/ 117

12.0/ 10.7 12.0
2.72/ 3.91 2.90
4.41/ 2.74 4.14
4.65/ 2.92 183/114

A++ / A+

A+++ / A+

22.00 27.50
4 4.50 9.00 15~55

28.00 35.00
5 6.00 12.10 15~55

5~25

5~25













1, 2, 220~240 V, 50 Hz 260 XL 105

1, 2, 220~240 V, 50 Hz 260 XL 95

A

A

2 (4/6)

2 (4/6)

29

29

29

29

43

47

1+1/4''

1+1/4''

147

147

595 x 1,800 x 700

595 x 1,800 x 700

1, 2, 220~240 V, 50 Hz

1, 2, 220~240 V, 50 Hz

Rotary Comp

Rotary Comp

-

-

51

52

50

51

69

70

74.0

107.0

940 x 998 x 330

940 x 1,420 x 330

R410A (Fluorinated greenhouse gas, GWP=2,088)

5.01

7.31

2.4

3.5

9.52 (3/8'')

9.52 (3/8'')

15.88 (5/8'')

15.88 (5/8'')

30

70

20

30

10

10

-25~35

-25~35

10~46

10~46

-25~43

-25~43

-25~24

-25~24

10~46

10~46

Accessories

Touch Controller MWR-WW10N

Touch Controller MCM-A300N

DMS2.5 MIM-D01AN

Wi-Fi Kit MIM-H04EN

External Room Sensor MRW-TA

Backup Heater (4/6kW) MHC-*00FE

AE260TNWTEH/EU
AE160MXTPEH/EU
MWR-WW10N
16.0/ 14.6 14.5
3.95/ 5.32 3.84
4.05/2.74 3.78
4.63/3.06 182/ 119 A+++ / A+ 32.00 40.00
7 7.70 15.40 15~55 5~25



1, 2, 220~240 V, 50 Hz 260 XL 95 A
2 (4/6) 29 29 47
1+1/4'' 147
595 x 1,800 x 700 1, 2, 220~240 V, 50 Hz
Rotary Comp 55 54 73
107.0 940 x 1,420 x 330
7.31 3.5 9.52 (3/8'') 15.88 (5/8'') 70 30 10 -25~35 10~46 -25~43 -25~24 10~46

AE260TNWTEH/EU AE090MXTPGH/EU
MWR-WW10N

AE260TNWTEH/EU AE120MXTPGH/EU
MWR-WW10N

9.0/ 7.7 8.0
2.12/ 2.82 1.86
4.25/2.69 4.30
4.44/2.86 175/ 111

12.0/ 10.7 12.0
2.72/ 3.91 2.90
4.41/ 2.74 4.14
4.65/2.92 183/ 114

A+++ / A+

A+++ / A+

10.00 16.10
4 4.50 9.00 15~55

10.00 16.10
5 6.00 12.10 15~55

5~25

5~25













1, 2, 220~240 V, 50 Hz 260 XL 105

1, 2, 220~240 V, 50 Hz 260 XL 95

A

A

2 (4/6)

2 (4/6)

29

29

29

29

43

47

1+1/4''

1+1/4''

147

147

595 x 1,800 x 700

595 x 1,800 x 700

3, 4, 380~415 V, 50 Hz

3, 4, 380~415 V, 50 Hz

Rotary Comp

Rotary Comp

-

-

51

52

50

51

69

70

76.0

107.0

940 x 998 x 330

940 x 1,420 x 330

R410A (Fluorinated greenhouse gas, GWP=2,088)

5.01

7.31

2.4

3.5

9.52 (3/8'')

9.52 (3/8'')

15.88 (5/8'')

15.88 (5/8'')

30

70

20

30

10

10

-25~35

-25~35

10~46

10~46

-25~43

-25~43

-25~24

-25~24

10~46

10~46

AE260TNWTEH/EU
AE160MXTPGH/EU
MWR-WW10N
16.0/ 14.6 14.5
3.95/ 5.32 3.84
4.05/2.74 3.78
4.63/ 3.06 182/ 119 A+++ / A+
12.00 16.10
7 7.70 15.40 15~55 5~25



1, 2, 220~240 V, 50 Hz 260 XL 95 A
2 (4/6) 29 29 47
1+1/4'' 147
595 x 1,800 x 700 3, 4, 380~415 V, 50 Hz
Rotary Comp 55 54 73
107.0 940 x 1,420 x 330
7.31 3.5 9.52 (3/8'') 15.88 (5/8'') 70 30 10 -25~35 10~46 -25~43 -25~24 10~46

*35dB(A) is only applicable for 6kW and 9kW outdoor units down to +4°C stated in 3 m distance in an anechoic environment.
**A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++
1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB].
2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB].
365°C down to +10°C (max. 60°C down to -5°C)
4Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions.
5 ODU : Outdoor Unit, IDU : Indoor Unit
67

TDM Plus TDM Plus

Specifications
TDM Plus with Third party tank connection (R410A)
· 'All in one' air-to-water and air-to-air system · Connectable with R410A Split ODU in combination of third party Tank · Compatible with room thermostats, solar pumps, 2- or 3-way valves and back-up boilers

Indoor Unit Outdoor Unit

System
Wall-Mounted Hydro Unit Outdoor Unit
Operation

Operation

Nominal Capacity

Heating A7/W35¹/ A7/W55² Cooling A35/W18¹

Power Input (Nominal)

Heating A7/W35¹ / A7/W55² Cooling A35/W18¹

COP (Nominal Heating) A7/W35¹

kW kW kW kW W/W

EER (Nominal Cooling) A35/W18¹

W/W

SCOP LWT 35°C/ 55°C

W/W

Seasonal space heating enr.efficiency s LWT 35°C/ 55°C

ETA%

Seasonal Space Heating Eff. Class LWT 35°C/ 55°C

Current

MCA

A

MFA

A

Maximum Allowable IDU6 Connections (Hydro A2W Unit Not Included)

Max. Number

EA

of IDU6

Total Capacity

kW

Min. (Cooling)

Total Capacity

kW

Min. (Cooling)

Leaving Water Temperature3 Heating



Cooling Functions Smart Grid Ready/ PV Enabled
3-Step Quiet Mode 2-zone Control4 Power Supply

 , #, V, Hz

Expansion Vessel

litres

Heater Sound
Piping

Back-up heater Capacity Sound Pressure5 Sound Power Water pipe

Std Std Inlet/Outlet

kW dB(A) dB(A) , inch

Dimensions Net Weight

kg

Net Dimensions (WxHxD)

Power Supply

Compressor Type

Base Heater Capacity

Sound

Sound Pressure5

Heating Std

mm , V, Hz kW dB(A)

Dimensions

Sound Power Net Weight Net Dimensions (WxHxD)

Cooling Std Heating Std

dB(A) dB(A) kg mm

Refrigerant Type

-

Factory Charging

tCOe

Piping

Piping Connections

Liquid Pipe

Gas Pipe

Piping Length (ODU-IDU)5 Level Difference (IDU-IDU)5 Chargeless Length Ambient Temperature A2W

Max.[Equiv.] Max.
Heating Cooling

kg
, mm (inch) , mm (inch) m
m
m



DHW



Ambient Temperature A2A

Heating



Cooling



AE090MNYDEH/EU AE044MXTPEH/EU
4.4/ 3.8 5.1
0.93/ 1.37 1.03
4.73/2.80 4.95
4.41/ 2.83 173/ 110
A++ / A+ 18 25.0 2
2.2
4.4 15~55 (H/P : 25~55)
5~25 -
 
1, 2, 220~240 V, 50 Hz 8 4 31 48
1+1/4'' 45.5 510 x 850 x 315 1, 2, 220~240 V, 50 Hz Rotary Comp
47 46 65 61 880 x 793 x 310
5.43 2.6 9.52 (3/8'')
15.88 (5/8'') 30 20 10
-25~35 10~46 -25~43 -25~24 10~46

AE090MNYDEH/EU AE066MXTPEH/EU

AE090MNYDEH/EU AE090MXTPEH/EU

6.6/ 4.8 6.7
1.47/ 1.85 1.48
4.49/2.59 4.53
4.41/2.96
173/ 115
A++ / A+ 20 25.0
3

9.0/ 7.7 8.0
2.12/ 2.82 1.85
4.25/2.72 4.32
4.42/ 3.01
174/ 117
A++ / A+ 22 27.5
4

3.3

4.5

6.6

9.0

15~55 (H/P : 25~55) 5~25 -


15~55 (H/P : 25~55) 5~25 -






1, 2, 220~240 V, 50 Hz

1, 2, 220~240 V, 50 Hz

8

8

4

4

31

31

48

48

1+1/4''

1+1/4''

45.5

45.5

510 x 850 x 315

510 x 850 x 315

1, 2, 220~240 V, 50 Hz

1, 2, 220~240 V, 50 Hz

Rotary Comp

Rotary Comp

-

-

48

51

47

50

67

69

61

74

880 x 793 x 310

940 x 998 x 330

R410A (Fluorinated greenhouse gas, GWP=2,088)

5.43

5.01

2.6

2.4

9.52 (3/8'')

9.52 (3/8'')

15.88 (5/8'')
30 20 10 -25~35 10~46 -25~43 -25~24 10~46

15.88 (5/8'')
30 20 10 -25~35 10~46 -25~43 -25~24 10~46

AE090MNYDGH/EU AE090MXTPGH/EU
9.0/ 7.7 8.0
2.12/ 2.82 1.86
4.25/2.69 4.30
4.44/ 2.86 175/ 111
A+++ / A+ 10 16.1 4
4.5
9.0 15~55 (H/P : 25~55)
5~25 -
 
3, 4, 380~415 V, 50 Hz 8 6 31 48
1+1/4'' 46.5 510 x 850 x 315 3, 4, 380~415 V, 50 Hz Rotary Comp
51 50 69 76 940 x 998 x 330
5.01 2.4 9.52 (3/8'')
15.88 (5/8'') 30 20 10
-25~35 10~46 -25~43 -25~24 10~46

68

EHS Controller (included) MWR-WW00N

Touch Controller MCM-A300N

Accessories
DMS2.5 MIM-D01AN

Wi-Fi Kit MIM-H04EN

External Room Sensor MRW-TA

AE160MNYDEH/EU AE120MXTPEH/EU
12.0/ 10.7 12.0
2.72/ 3.91 2.90
4.41/2.74 4.14
4.65/ 2.92 183/ 114
A+++ / A+ 28 35.0 5
6.0
12.1 15~55 (H/P : 25~55)
5~25 -
 
1, 2, 220~240 V, 50 Hz 8 6 38 55
1+1/4'' 46.5 510 x 850 x 315 1, 2, 220~240 V, 50 Hz Rotary Comp
52 51 70 107 940 x 1,420 x 330
7.31 3.5 9.52 (3/8'')
15.88 (5/8'') 70 30 10
-25~35 10~46 -25~43 -25~24 10~46

AE160MNYDGH/EU AE120MXTPGH/EU

AE160MNYDEH/EU AE160MXTPEH/EU

12.0/ 10.7 12.0
2.72/ 3.91 2.90
4.41/2.74 4.14
4.65/ 2.92
183/ 114
A+++ / A+ 10 16.1
5

16.0/ 14.6 14.5
3.95/ 5.32 3.84
4.05/2.74 3.78
4.63/ 3.06
182/ 119
A+++ / A+ 32 40.0
7

6.0

7.7

12.1

15.4

15~55 (H/P : 25~55) 5~25 -


15~55 (H/P : 25~55) 5~25 -






3, 4, 380~415 V, 50 Hz

1, 2, 220~240 V, 50 Hz

8

8

6

6

38

38

55

55

1+1/4''

1+1/4''

46.5

46.5

510 x 850 x 315

510 x 850 x 315

3, 4, 380~415 V, 50 Hz

1, 2, 220~240 V, 50 Hz

Rotary Comp

Rotary Comp

-

-

52

55

51

54

70

73

107

107

940 x 1,420 x 330

940 x 1,420 x 330

R410A (Fluorinated greenhouse gas, GWP=2,088)

7.31

7.31

3.5

3.5

9.52 (3/8'')

9.52 (3/8'')

15.88 (5/8'')
70 30 10 -25~35 10~46 -25~43 -25~24 10~46

15.88 (5/8'')
70 30 10 -25~35 10~46 -25~43 -25~24 10~46

AE160MNYDGH/EU AE160MXTPGH/EU
16.0/ 14.6 14.5
3.95/ 5.32 3.84
4.05/2.74 3.78
4.63/ 3.06 182/ 119
A+++ / A+ 12 16.1 7
7.7
15.4 15~55 (H/P : 25~55)
5~25 -
 
3, 4, 380~415 V, 50 Hz 8 6 38 55
1+1/4'' 46.5 510 x 850 x 315 3, 4, 380~415 V, 50 Hz Rotary Comp
55 54 73 107 940 x 1,420 x 330
7.31 3.5 9.52 (3/8'')
15.88 (5/8'') 70 30 10
-25~35 10~46 -25~43 -25~24 10~46

*35dB(A) is only applicable for 6kW and 9kW outdoor units down to +4°C stated in 3 m distance in an anechoic environment.
**A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++
1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB].
2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB].
365°C down to +10°C (max. 60°C down to -5°C)
4Not provided by Samsung.
5Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions.
6 ODU : Outdoor Unit, IDU : Indoor Unit
69

TDM Plus TDM Plus

Specifications

TDM Plus WindFreeTM Deluxe
· Three-step cooling: Fast Cooling mode · WindFreeTM Cooling Mode · Wi-Fi Control with SmartThings and Bixby voice controls

· Equipped with NASA communication protocol · Equipped with Easy Filter Plus

Power Supply Capacity Power Input (Nominal) Current Input (Nominal) Fan
Fan motor Piping Connections Wiring connections Refrigerant Sound Dimensions Functions Air Flow Air Purification
Operating Mode
Other Functions

Type Model Name
Cooling Heating Cooling Heating Cooling Heating Type Quantity Air Flow Rate H/M/L
Type Output xn Liquid Pipe Gas Pipe For power supply below 20m/over 20m (min) Communication (min) Type Control Method 1 Sound Pressure H/M/L/WF 2 Sound Power Net Weight Net Dimensions (WxHxD)

, #, V, Hz kW kW W W A A EA m³/min l/s W , mm(inch) , mm(inch) mm²
mm² dB(A) dB(A) kg mm

WindFreeTM Cooling

Air Direction Control (Up/Down)

Air Direction Control (Left/Right)

Auto Fan speed

Tri-Care Filter

Easy Filter Plus

Auto Clean (Self Cleaning)

2 Step Cooling

AI Auto Comfort with Wi-Fi & MDS (direct/indirect)

AI Auto Comfort with Wi-Fi

Auto Mode (without Wi-Fi)

Fast Cooling

Good Sleep

Eco

Dehumidifi cation

Fan

Quiet

Samsung SmartThings

MDS (Motion Detect Sensor)

Indoor Temp. Display

Display On/Off

88 Display

Beep On/Off

Auto Changeover

Auto Restart

TDM Plus WindFreeTM Deluxe AE022TNXDEH/EU
1, 2, 220~240 V, 50 Hz 2.20 2.50 24.0 24.0 0.16 0.16
Cross flow Fan 1
5.7/5.0/4.5 95.0/83.3/75.0
BLDC 27x1 6.35 (1/4) 12.7 (1/2)
1.5/2.5
0.75
EEV NOT INCLUDED 34/32/30/27 51 8.50
820 x 299 x 215

TDM Plus WindFreeTM Deluxe
AE028TNXDEH/EU
1, 2, 220~240 V, 50 Hz 2.80 3.20 30.0 30.0 0.20 0.20
Cross flow Fan 1
8.5/7.7/6.9 141.7/128.3/115.0
BLDC 27x1 6.35 (1/4) 12.7 (1/2)
1.5/2.5
0.75 R410A (Fluorinated greenhouse gas, GWP=2,088)
EEV NOT INCLUDED 34/33/32/26 52 9.00
820 x 299 x 215

TDM Plus WindFreeTM Deluxe AE036TNXDEH/EU
1, 2, 220~240 V, 50 Hz 3.60 4.00 37.0 37.0 0.25 0.25
Cross flow Fan 1
10.3/9.1/8.3 171.7/151.7/138.3
BLDC 27x1 6.35 (1/4) 12.7 (1/2)
1.5/2.5
0.75
EEV NOT INCLUDED 40/36/34/26 56 9.00 820 x 299 x 215


Auto Auto

-
  
-
      
-
    


Auto Auto

-
  
-
      
-
    


Auto Auto

-
  
-
      
-
    

70

Accessories

1-room EEV Kit MEV-E**SA

2/3 Room EEV Kit MXD-E**K***A

Wireless Remote Controller (included)
AR-EH03E

Touch Controller MWR-SH11N

Wired Remote Controller
MWR-WE13N

DMS2.5 MIM-D01AN

Wi-Fi Kit MIM-H04EN

TDM Plus WindFreeTM Deluxe AE056TNXDEH/EU

TDM Plus WindFreeTM Deluxe AE071TNXDEH/EU

1, 2, 220~240 V, 50 Hz 5.60 6.30 52.0 52.0 0.35 0.35
Cross flow Fan 1
15.7/13.8/12.0 261.7/230.0/200.0
BLDC 27x1 6.35 (1/4) 12.7 (1/2)

1, 2, 220~240 V, 50 Hz 6.80 7.00 60.0 60.0 0.40 0.40
Cross flow Fan 1
16.8/15.0/13.2 280.0/250.0/220.0
BLDC 27x1 9.52 (3/8) 15.88 (5/8)

1.5/2.5

1.5/2.5

0.75

0.75

R410A (Fluorinated greenhouse gas, GWP=2,088)

EEV NOT INCLUDED

EEV NOT INCLUDED

40/37/34/29

43/40/37/29

58

62

11.50

11.50

1,055 x 299 x 215

1,055 x 299 x 215


Auto Auto

-
  
-
      
-
    


Auto Auto

-
  
-
      
-
    

Capacities are based on (Equivalent refrigerant piping 7.5m, Level differences 0m)
Cooling : Indoor temperature 27°C DB, 19°C WB / Outdoor temperature 35°C DB, 24°C WB
Heating : Indoor temperature 20°C DB, 15°C WB / Outdoor temperature 7°C DB, 6°C WB
1 EEV Kit is necessary to control the refrigerant flow in the TDM Plus WindFreeTM Deluxe (EEV Excluded), please order EEV Kit separately.
2 Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions.
71

Specifications
TDM Plus Slim Duct
· Slim design with thickness of just 199 mm · Antibacterial filter included

Specifications

TDM Plus MSP Duct
· External statuc pressure range from 0 to 1.4 mmAq · Built-in electronic expansion valve (EEV) for refrigerant flow control (2000 step) · Long-life washable permanent filter is included

· Auto Restart function. · Built-in condensation drain pump (750 mmH2O) · SPi Ioniser device (optional)

Power Supply Performance Power
Fan
Fan Motor Piping Connections Refrigerant Sound Dimensions Optional Accessories

Type Model Name
Capacity
Power Input
Current Input
Type Quantity Air Flow Rate External Pressure
Type Output x n Liquid Pipe Gas Pipe Type Sound Pressure Sound Power Net Weight Net Dimensions (W×H×D) Drain Pump

Cooling / Heating Cooling / Heating Cooling / Heating
H/M/L (UL) Max. (Min/ Std/Max)
H/M/L
Model Max. lifting Height/ Displacement

, #, V, Hz kW
W
A
EA m³/min mmAq Pa W , mm (inch) , mm (inch) dB(A) dB(A) kg mm mm / Litre/h

Slim Duct AE022MNLDEH/EU
1, 2, 220~240 V, 50 Hz 2.2/2.5
55/55
0.30/0.30 Sirocco Fan
2 7.0 / 6.1 / 5.3
0/1/3 0/9.8/29.4 SSR non-feedback
28x1 6.35 (1/4) 12.7 (1/2)
26 / 24 / 21 49 19
700 x 199 x 600 MDP-E075SEE3D (Built-in)

Slim Duct AE028MNLDEH/EU

Slim Duct AE036MNLDEH/EU

1, 2, 220~240 V, 50 Hz 2.8/3.2

1, 2, 220~240 V, 50 Hz 3.6/4.0

60/60

65/65

0.32/0.32

0.33/0.33

Sirocco Fan

Sirocco Fan

2

2

7.5 / 6.6 / 5.6 0/1/3
0/9.8/29.4

7.5 / 6.6 / 5.6 0/1/3
0/9.8/29.4

SSR non-feedback

SSR non-feedback

28x1

28x1

6.35 (1/4)

6.35 (1/4)

12.7 (1/2)

12.7 (1/2)

R410A (Fluorinated greenhouse gas, GWP=2,088)

28 / 26 / 23

32 / 30 / 27

49

51

19

19,5

700 x 199 x 600

700 x 199 x 600

MDP-E075SEE3D (Built-in)

MDP-E075SEE3D (Built-in)

Slim Duct AE056MNLDEH/EU
1, 2, 220~240 V, 50 Hz 5.6/6.3
95/95
0.53/0.53 Sirocco Fan
2 12.0 / 10.5 / 9.0
0/2/4 0/19.6/39.2 SSR non-feedback
28x1 6.35 (1/4) 12.7 (1/2)
36 / 34 / 31 55 24,5
900x199x600 MDP-E075SEE3D (Built-in)

750 / 24

750 / 24

750 / 24

750 / 24

Accessories

Drain Pump (Built-in)
MDP-E075SEE3D

Remote Control AR-EH00

Touch Controller MWR-SH11N

Wired Remote Control
MWR-WE13N

Wireless Receiver Kit
MRK-A10N

Touch Controller MCM-A300N

DMS2.5 MIM-D01AN

Wi-Fi Kit MIM-H04EN

External Room Sensor
MRW-TA

Y-joint MXJ-YA1509M

Power Supply Performance Power
Fan
Fan Motor Piping Connections Refrigerant Sound Dimensions Optional Accessories

Type Model Name
Capacity
Power Input
Current Input
Type Quantity Air Flow Rate External Pressure
Type Output x n Liquid Pipe Gas Pipe Type Sound Pressure Sound Power Net Weight Net Dimensions (W×H×D) Drain Pump

Cooling / Heating Cooling / Heating Cooling / Heating
H/M/L (UL) Max. (Min/ Std/Max)
H/M/L
Model

, #, V, Hz kW
W
A
EA m³/min mmAq Pa W , mm (inch) , mm (inch) dB(A) dB(A) kg mm -

Max. lifting Height/ Displacement

mm / Litre/h

MSP Duct AE071MNMPEH/EU

MSP Duct AE090MNMPEH/EU

1, 2, 220~240 V, 50 Hz 7.1/8.0

1, 2, 220~240 V, 50 Hz 9.0/10.0

120/120

145/145

1.0/1.0

1.2/1.2

Sirocco Fan

Sirocco Fan

2

2

22 / 19 / 16 0 / 3 / 15 0 / 29.4 / 147.2

29 / 25 / 22 0 / 4 / 15
0 / 29.4 / 147.2

BLDC Feedback

BLDC Feedback

153x1

153x1

9.52 (3/8")

9.52 (3/8")

15.88 (5/8")

15.88 (5/8")

R410A (Fluorinated greenhouse gas, GWP=2,088)

37 / 33 / 29

38 / 35 / 32

57

58

25,5

33

850x250x700

1,200x250x700

MDP-G075SQ (Built-in) MDP-G075SP (External)

MDP-G075SQ (Built-in) MDP-G075SP (External)

750 / 24

750 / 24

Accessories

Drain Pump (Built-in)
MDP-G075SQ

External Drain Pump
MDP-G075SP

Remote Control Touch Controller

AR-EH00

MWR-SH11N

Wired Remote Control
MWR-WE13N

Touch Controller MCM-A300N

DMS2.5 MIM-D01AN

Wi-Fi Kit MIM-H04EN

External Room Sensor
MRW-TA

Wireless Receiver Kit
MRK-A10N

Y-joint MXJ-YA1509M

TDM Plus TDM Plus

72

73

Specifications

TDM Plus Console
· SPi Ioniser device (included) · Slim design with 199mm in depth · Built-in electronic expansion valve (EEV) for refrigerant flow control (2,000 step)

· Long-life washable permanent filter · Auto Restart function · Two separate air outlets, upper (cooling) and bottom (heating) to avoid stratifications

Dimensional Drawings
TDM Plus Tank Integrated Hydro Unit
AE200TNWTEH/EU, AE260TNWTEH/EU

Power Supply Performance Power
Fan
Piping Connections Refrigerant Sound Dimensions

Type Model Name
Capacity
Power Input
Current Input
Type Quantity Air Flow Rate Liquid Pipe Gas Pipe Type Sound Pressure Sound Power Net Weight Net Dimensions (W×H×D)

Cooling / Heating Cooling / Heating Cooling / Heating
H/M/L (UL)
H/M/L

, #, V, Hz kW
W
A
EA m³/min , mm (inch) , mm (inch) dB(A) dB(A) kg mm

Console AE022MNJDEH/EU
1, 2, 220~240 V, 50 Hz 2.2/2.5
16/16
0.13/0.13 Turbo Fan
1 6.3 / 5.4 / 4.9
6.35 (1/4) 12.7 (1/2)
34 / 32 / 30 52 15,5
720 x 620 x 199

Console AE028MNJDEH/ EU

Console AE036MNJDEH/ EU

1, 2, 220~240 V, 50 Hz 2.8/3.2

1, 2, 220~240 V, 50 Hz 3.6/4.0

30/30

35/35

0.25/0.25

0.29/0.29

Turbo Fan

Turbo Fan

1

1

7.0 / 6.0 / 5.0

8.50 / 7.50 / 6.50

6.35 (1/4)

6.35 (1/4)

12.7 (1/2)

12.7 (1/2)

R410A (Fluorinated greenhouse gas, GWP=2,088)

38 / 36 / 34

39 / 37 / 34

58

59

16

16

720 x 620 x 199

720 x 620 x 199

Console AE056MNJDEH/ EU
1, 2, 220~240 V, 50 Hz 5.6/6.3
62/62
0.49/0.49 Turbo Fan
1 13.0 / 11.5 / 10.0
6.35 (1/4) 12.7 (1/2)
43 / 40 / 37 64 16
720 x 620 x 199

Accessories

Touch Controller MWR-SH11N

Remote Control (Included)
MR-EH00

Touch Controller MCM-A300N

DMS2.5 MIM-D01AN

Wi-Fi Kit MIM-H04EN

External Room Sensor MRW-TA

Wired Remote Control MWR-WE13N

Y-joint MXJ-YA1509M

TDM Plus TDM Plus

NO
1 2 3 4 5 6 7 8 9

Name
Space heating Inlet Space heating Outlet
DHW Inlet Secondary water return
DHW Outlet Refrigerant liquid pipe Refrigerant Gas pipe
T/Pv/v Drain Holes

AE200TNWTEH/EU

Description

AE260TNWTEH/EU

Ø28 Ø28 Ø22 N/A Ø22 Ø9.52 Ø15.88 Female PT 1/2"

Ø28 Ø28 Ø22 Ø22 Ø22 Ø9.52 Ø15.88 Female PT 1/2"

(Option) Connect with the provided drain plug

74

75

TDM Plus

793 13.7 52.7 332.0
779 116
178.8 241.8

Dimensional Drawings
TDM Plus Outdoor
AE044/066MXTPEH/EU
880.0

310 364.0

541 880
3 2 1

660.0 4

MOUNT BOLT SPEC : M6 x 4

NO
1 2 3 4

Name
Refrigerant gas pipe for air Refrigerant gas pipe for water
Refrigerant liquid pipe Drain holes

76

4.4 kW

Description
15.88("5/8) 15.88("5/8) 9.52("3/8) Connect with the provided drain plug.

6.6 kW

TDM Plus Outdoor
AE090MXTP*H/EU
940
580.0 313

330 384.0

998 24

65 620

88 30

30 80

MOUNT BOLT SPEC : M6 x 4 4

55 95 55 95

6 5 4

55 80

22 67

Rear View

328.0 75
328

3

1

7

2

21 3

37

Detail for pipe position

66

104

NO
1 2 3 4 5 6 7

Name
Refrigerant liquid pipe Refrigerant gas pipe for air Refrigerant gas pipe for water Knockout hole for pipe intake
Power wiring conduits Communication wiring conduits
Drain holes

Description
9 kW 9.52("3/8) 9.52("3/8) 15.88("5/8) 15.88("5/8) Front / Side / Rear / Bottom Front / Side / Rear, 34("1-3/8) Front / Side / Rear, 22("7/8) Connect with the provided drain plug.

77

458 495 537
TDM Plus

TDM Plus 1420

Dimensional Drawings
TDM Plus Outdoor
AE120/160MXTPH/EU 940
580 313

384.0

330

24

6

6

5

5

4

4

55 80

55 95 55 95

620.0

88 30

30 80

MOUNT BOLT SPEC : M6 x 4 4

22 67

75 328.0

7 3 1 2

483.7 520.5 562.8

NO
1 2 3 4 5 6 7
78

Name
Refrigerant liquid pipe Refrigerant gas pipe for air Refrigerant gas pipe for water Knockout hole for pipe intake
Power wiring conduits Communication wiring conduits
Drain holes

Detail for Service valve position

40.5 66.4 104.8

12 kW
15.88("5/8) 15.88("5/8) Front / Side / Rear / Bottom Front / Side / Rear, 34("1-3/8) Front / Side / Rear, 22("7/8) Connect with the provided drain plug.

Description 9.52("3/8)

16 kW
15.88("5/8) 15.88("5/8) Front / Side / Rear / Bottom Front / Side / Rear, 34("1-3/8) Front / Side / Rear, 22("7/8) Connect with the provided drain plug.

WindFreeTM Deluxe
AE022/028/036TNXDEH/EU

889.0

215

466.6

889.0

422.4

65.0 245.0

64.0

397.0 64.0

65. 84.0

61.5

29.0

48.3

299.0 29.0

57.9 65.2 299

79

TDM Plus

TDM Plus
299.0 29.0

Dimensional Drawings
WindFreeTM Deluxe
AE056/071TNXDEH/EU

1054.5

215

65.0 175.6

517.5

1054.5

537.0

631.5

64.0

64.0

61.5 29.0

62.4
65.0 84.0

80

58.1 65.0 299

650 600
477 Suspension position 71 100 10
OD25 26 115.5 145.5 199 151.6 18 100
TDM Plus

TDM Plus Slim Duct

AE022/028/036MNLDEH/EU

13

565.5

5

Suction

738.4 Suspension position

8

7

6

600

660 Air outlet duct flange

700

Discharge

18-3.2 Hole All around

700

800

500

NO
1 2 3 4 5 6 7 8

Name
Liquid pipe connection Gas pipe connection
Drain pipe connection without drain pump Drain pipe connection with drain pump
Power supply/Communication connection Air discharge grille flange Return air side Hook

Description 9.52("3/8) 6.35(1/4") 12.70(1/2") VP25(OD 32, ID 25) VP25(OD 32, ID 25)
9.52 or M10

12 4

182

3

246

333

81

TDM Plus

Dimensional Drawings
TDM Plus MSP Duct

AE056MNLDEH/EU

10

100

199

900

465

293

18 939
899

118
5 101
600 or More (Service Space)

81

61

600 or More (Service Space)

477

8x100=800 6
860

27 115 145

152 100 18

4

53 83 171

181 245

21

3

332

NO
1 2 3 4 5 6

Name
Gas pipe connection Liquid pipe connection Drain pipe connection Knockout hole for Drain pump Power supply & Communication wiring conduit Air outlet duct flange

82

5
Description 12.7(1/2) 6.35(1/4) VP-25(OD 32, ID 25) Option kit
-

TDM Plus MSP Duct
AE071MNMPEH/EU

25 or More 25 or More

900

6 500 or More

7

Air Inlet

[Service Space]

Ceiling

186 164 27
700 or More [Service Space]
53 94 2x90=180

604

700

740

220

Air Inlet

Air Outlet

Air Outlet 850
952

250

220

818 7x100=700
59

5 21

125 213 323

34

57

NO
1 2 3 4 5 6 7

Name
Liquid pipe connection Gas pipe connection Drain pipe connection
Power supply & Communication wiring conduit Air suction flange
Air discharge flange Hook

Description
9.52(3/8) 15.88(5/8) VP-25(OD 32, ID 25)
Use M8~M10 bolt(4ea)

83

TDM Plus

Dimensional Drawings
TDM Plus MSP Duct
AE090MNMPEH/EU

TDM Plus Console
AE022/028/036/056MNJDEH/EU

185 25 or More 25 or More
163 27
700 or More [Service Space]
53 94 2x90=180

TDM Plus

TDM Plus 220

1250

7

6 500 or More

Air Inlet

[Service Space]

Ceiling

604

700 220

740

Air Inlet

250

Air Outlet 34

Air Outlet 1200 1302
1168 11x100=1100

5 21

125 213 323

34

590 199

88 70
620 48

49 65
5

720
86 124

SECTION C-C

C

49

5

65

74 147 164

96 89 130

70 88 153 128

4 2

1A

A

119

C

3

47

121

29

2

1

SECTION A-A

NO
1 2 3 4 5 6 7

Name
Liquid pipe connection Gas pipe connection Drain pipe connection
Power supply & Communication wiring conduit Air suction flange
Air discharge flange Hook

84

Description
9.52(3/8) 15.88(5/8) VP-25(OD 32, ID 25)
Use M8~M10 bolt(4ea)

NO
1 2 3 4 5

Name
Liquid pipe connection Gas pipe connection Drain pipe connection
Power supply & Communication wiring conduit Knockout hole for drain hose

Description
6.35(1/4) 12.7(1/2) ID 18mm[11/16 inch] Hose
-

85

TDM Plus TDM Plus

Dimensional Drawings
Wall-Mounted Hydro Unit
AE090/160MNYD*H/EU

NO
1 2 3 4

Name
Gas Ref. Pipe Liquid Ref. Pipe Water Pipe (Inlet/Outlet) Drain Hose Connector

Description
 6.35 (1/4") (9kW),  9.52 (3/8) (16kW)  15.88 (5/8)
BSPP male 11/4

86

Project: Atico en el Retiro (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Belén Imaz
87

88

Controls

TDM Plus Controls

89

Line-up

Category

Product

Individual Control Wireless Remote Controller System

Wired Remote Controller

Model AR-EH03E MR-EH00 MWR-WW10N

Touch Controller

MWR-WW00N MWR-WE13N MWR-SH11N

Mono Control Kit

MIM-E03CN

Centralised Control System

Touch Controller

Wi-Fi Kit 2.0

MCM-A300N MIM-H04EN

Integrated Control System

DMS 2.5

MIM-D01AN

Interface Module External Contact Interface Module & Gateway

MIM-B14

Pulse Interface Module (PIM)

MIM-B16N

Modbus Interface module

MIM-B19N

Others

S-Converter

MIM-C02N

External room sensor

MRW-TA

Receiver Kit

MRK-A10N

EHS ClimateHub R32

EHS Mono R32

EHS Split R32

Compatibility Table

EHS with Third Party Tank

EHS Mono R32

EHS Split R32

EHS Split R410A

·

·

·

·*

·*

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

TDM Plus ClimateHub R410A
·

Wall-Mounted Hydro Unit
·*

Compatibility Table

TDM Plus R410A

TDM Plus WindFreeTM Deluxe

Slim Duct

·*
optional

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

MSP Duct optional
· ·
· · · · · · · · ·

Console
·*
· ·
· · · · · · · ·

Controls Controls

* No need to order separately, controller is already included.

90

91

Features
Controls | Individual Control
Wireless Remote Controller Standard with WindFreeTM AR-EH03E
Wired Remote Controller Standard type for EHS MWR-WW10N
Wired Remote Controller MWR-WE13N MWR-WW00N
Wired Remote Controller Touch Simple type MWR-SH11N
Mono Control Kit MIM-E03CN

Wireless / Wired Remote Controllers
· WindFreeTM On/Off · Filter replacement alarm reset · Simple On/Off timer · Indoor unit option code setting · Temperature setting range · Auto/Cool/Dry : 18 - 30 · Heat : 16 - 30 · Direct/Indirect function On/Off · Motion Detect Sensor necessary · Net dimensions (W x H x D): 48 x 138 x 24mm
· Full color 4.3" LCD screen · Easy and Intuitive UI · 2-zone Control · LCD Backlight · Multiple Language support* · IR receiver is included · Daylight Savings Time ·  /  Convertible · Error list display · Built-in room temperature sensor · SD slot · Net dimensions (W x H x D): 120 x 120 x 19mm
* Available languages: English, German, Spanish, French, Italian and Polish.
· Air conditioner/ERV operation setting (Horizontal air flow, WindFreeTM) · LCD Backlight · Air conditioner/ERV error monitoring · Air conditioner individual blade control · Filter cleaning alert/reset alert time · Air conditioner/ERV interlocking control · Energy saving control · Automatic operation stop function · Weekly operation schedule setting · Button restriction function · Built-in room temperature sensor · Real time clock (Daylight Savings Time) · Control max. 16 indoor units (Air conditioner + ERV) in group with single wired remote controller · Net dimensions (W x H x D): 120 x 124 x 19.5mm
· Touch screen wired remote controller · LCD Backlight · IR receiver is included · Away function · Quiet mode, Sleep mode · Reset filter cleaning alert indicator · Air conditioner Individual/group control · Operation On/Off timer function · WindFreeTM/Long horizontal wind · Button locking function · Eliminate Operation Mode function : Auto/Cool/Dry/Fan/Heat mode · Built-in room temperature sensor ·  /  Convertible · Relative temperature setting function : -3 ~ +3 setting · Control max. 16 indoor units in group with a single wired remote controller · Net dimensions (W x H x D): 94.2 x 122 x 19.5mm
· EHS R32 Mono control Kit · Includes remote controller (MWR-WW10N) and flow sensor · Mounting box with the control printed board assembly · Leaving and return water sensors · Domestic Hot Water sensor · Net Dimensions (WxHxD) mm 290 x 110 x 370 mm

Controls | Centralised Control
Touch Controller MCM-A300N
Wi-Fi Kit 2.0 MIM-H04EN
Controls | Integrated Control
DMS2.5 MIM-D01AN

Centralised Control Systems
· 7 inch touch LCD controller · Controls max. 128 indoor units · Controls max. 12 zones · Schedule control, Indoor unit usage restriction, View indoor unit error history · Net dimensions (W x H x D): 205 x 163 x 38mm
· Enhanced Convenience · Voice Control available through a smartphone with Bixby · Connected home with affordable units in every home using SmartThings · Welcome cooling and heating based on Geo-fencing · Individual indoor unit control · Personalized Climate Environment · Preferred automation · Multi-device experience interoperable with smart appliances · Energy Usage Monitoring · Current and daily, weekly or monthly energy usage* of the outdoor unit · Provides ease of installation · Easy set-up possible for up to 16 indoor units at once · Net dimensions (W x H x D): 185 x 130 x 29mm
Integrated Control Systems
· Built-in web server for PC-independent management and remote access control · Multiple upper-layer control access (S-NET 3, Web-client) · Weekly/Daily schedule control · Power distribution function · Current time management even during power failure (for 24 hours) · Emergency stop function with simple contact interface · Individual/Group control of up to 256 indoor units, AHU and ERV · User editable control logic · Accessible level management. · Dynamic security management · Operation & error history management · Data storage in non-volatile memory & SD memory · Net dimensions (W x H x D): 240 x 255 x 65mm

Controls Controls

* Calculated by Samsung's own algorithm, it cannot be used as a legal basis.

92

93

Features
Controls | Interface devices
External Contact Interface Module MIM-B14
Modbus Interface Module MIM-B19N
Pulse Interface Module (PIM) MIM-B16N

Module, Application Kit, Gateway
The Samsung Guestroom Management System saves users the energy and money wasted on cooling an unoccupied room. The air conditioner is activated when the Key-Tag is in place and turns off when the Key-Tag is removed.
An external contact interface module provides direct indoor unit control via an external contact signal, as well as window-synchronised indoor unit control. The emergency control function features simple contact input. Plus the module generates indoor unit operation/error state output through relay contacts.
· Direct indoor unit control by external contact signal · Window-synchronised indoor unit control · Emergency control with simple contact input · Indoor unit operation/error state output through relay contacts · Net dimensions (W x H x D): 50 x 80 x 35mm
A BMS or 3rd controller can control a Samsung SAC by using the Modbus protocol.
· BMS unit protocol: Modbus RS485 (2 wires, max. 1,000m) · Unit connection protocol: Samsung Control Layer Protocol (R1/R2) · Max. No. of connection units: 1 outdoor unit (4 outdoor units including
sub units in the case of modular installation) and 48 indoor units · Modbus interface module address range : up to 247 · Net dimensions (W x H): 50 x 80mm
The Watt-hour Meter Interface Module can be exclusively used for DMS 2.5 power distribution, displaying power consumption for each watt-hour meter.
· Exclusive use for DMS 2.5 power distribution · Connection with up to 8 watt-hour meters · Pulse interface with watt-hour meters · Watt-hour meter - by 3rd party · Net dimensions (W x H x D): 240 x 255 x 65mm

Controls | Others
S-Converter MIM-C02N
External Room Sensor MRW-TA
Receiver Kit MRK-A10N

Module, Application Kit, Gateway
Communication converting module to connect a Samsung system air conditioner to a PC
· Main reasons for use: - To connect with test run program [Test run program] - S-NET Pro: Conventional communication - S-NET Pro2: New communication
· Net dimensions (W x H x D): 66 x 92 x 28mm
· Indoor unit is operated by MRW-TA instead of its own sensor. · Wire length: 12 m (39 ft)
· Concealed wireless signal receiver · Filter replacement sign · Fan operation display · Operation Timer setting display · Operation On/Off button · Operation On display LED (blue) · Defrost operation display LED (red) · Net dimensions (W x H x D): 80 x 130 x 28mm

Controls Controls

94

95

96

Controls Accessories

Accessories

97

Accessories Accessories

Compatibility

Accessories EEV Kit (1/2/3 room)
Y-Joint Drain Pump
Backup Heater

Name Name 1 Indoor 2 Indoor
3 Indoor
(15.0 kW and below) Internal External Internal 4 kW 6 kW

Indoor unit
Model code MEV-E24SA MEV-E32SA

TDM Plus Slim Duct

TDM Plus MSP Duct

2.2-5.6 kW

7.1-9.0 kW

MXD-E24K132A

MXD-E24K200A

MXD-E32K200A

MXD-E24K232A

MXD-E24K300A

MXD-E32K224A

MXD-E32K300A

MXJ-YA1509M

·

·

MDP-E075SEE3D
·

MDP-G075SP
·

MDP-G075SQ
·

MHC-400FE MHC-600FE

TDM Plus WindFreeTM
Deluxe

TDM Plus Console

Wall-Mounted Hydro Unit

EHS ClimateHub

2.2- 7.1 kW
·
·
· · · · · · ·

2.2-5.6 kW

9.0/16.0 kW

200/260 L

·

·

·

·

(TDM Plus only) (TDM Plus only)

· ·

98

Project: Casa L (Spain) Project Architecture: ÁBATON
Interior Design: BATAVIA Photography: Carlos Muntadas
99

100

Design and Support

Accessories Design and Support

101

Samsung Climate Solutions Partner Portal
As one of Samsung's registered Climate Solutions partners, you will have access to our Partner Portal and its many benefits. Whether you are looking for marketing materials or technical product documentation, requesting technical support or registering for training, the Samsung Climate Solutions Partner Portal offers you everything you need to consistently deliver the best results.
Access technical resources
The Technical Resources section provides you with all of the relevant information you need to understand the product's functionality and to prepare and design projects. A library full of technical information is at your fingertips, ranging from technical data books, BIM files and certificates to exploded views, drawings and different kinds of manuals.

Request technical support
You can easily request technical support through the Samsung Partner Portal by reporting your case using our built-in ticketing system. You can rest assured that our well-trained technical experts will work to solve your issue as soon as possible.
Register for training
If you are dedicated to becoming a Samsung climate solutions expert, you can access Samsung's educational portal for training sessions provided by experienced trainers. The portal allows you to search for online courses and materials, test your climate solutions knowledge, and more. The Samsung Business Academy is here to help you succeed.1
1 The registration process for and availability of training courses may vary per country. Please contact your direct Samsung contact person for more information.

Obtain marketing resources

How to access

Potential buyers like to know that you are on the cutting edge of Samsung's latest innovations. To enable you to align with Samsung's marketing initiatives, the Partner Portal provides you with useful downloadable assets such as images and videos, designed to make your marketing activities easy and effective.

1 Register

2 Access

3 Manage account

4 Search and download

To register for the Samsung Climate Solutions Partner Portal, open your web browser1 and go to partnerhub.samsung.com/ climate to complete the registration form.

Your information will be verified and your account will be activated. You will receive your personal login details.

1 Google Chrome is the recommended web browser for using the Samsung Climate Solutions Partner Portal.

Keep your account details up to date and invite your colleagues to join.

Access a full library of resources, request technical support, or sign up for a Climate Solutions Academy training session.

102

103

Design and Support Design and Support

104

DVM Pro 2.0

Design and Support Design and Support

105

Design and Support Design and Support

Samsung DVM Pro 2.0 NEW
Samsung introduces new updated version of DVM Pro version 2.0. Product selection is extended and now the tool is also available for EHS and HVM lineup. Samsung DVM Pro 2.0 is an advanced design automation programme which helps you to select the most suitable equipment for easily and precisely designing your air conditioning system. It helps to ensure that the system's design falls within Samsung's engineering guidelines. With its reports, pipe and wire diagrams, additional refrigerant values and other information, Samsung DVM Pro 2.0 is a powerful tool for engineers, designers or installers.
Sales Mode
Sales Mode enables users to define their requirements and select air conditioning products quickly and easily.

Product selection List of equipment, including indoor units, outdoor units, controls and accessories
Piping schematics Basic or manual selection with system check and capacity simulation

Reports Specifications, diagrams in DWG & BMP format, quotations
Control systems Automatic control unit selection

106

Updated Toolbar NEW User-friendly tool bar helps to guide intuitively
Wiring schematics Automatic diagrams including communication wiring for indoor/outdoor/ control units and electric power meters

CAD Mode
CAD Mode is an in-depth and precise design tool that enables users to design their air conditioning systems using AutoCAD software1.
1 Sourced separately.

Pipe sizing & lengths Refrigerant & drain pipe sizing
System check Installation regulation & refrigerant charging

Automatic selection Refnet joint, header & distributor kit
Performance simulation Capacity correction tool against specific design conditions

Automatic report Piping installation
Design wihout AutoCAD NEW Compatible with AutoCAD and AutoCAD LT for DWG.

How to access

1

2

Register

Select

Go to dvmpro.mkt.samsung.com to access the Samsung DVM Pro 2.0 Portal1. If you do not have access yet, complete the registration process and you will be sent the access details.

Click on DVM Pro 2.0 via the main menu and scroll to the end of the page to select the option DVM Pro 2.0 download.

1 Google Chrome is the recommended web browser for using the Samsung DVM Pro 2.0 Portal.

3 Download
Download the DVM Pro 2.0 installation file, view the user manuals, and start designing your project.
107

Samsung Climate Solutions Academy

Design and Support Design and Support

108

109

Samsung Climate Solutions Academy
Samsung Climate Solutions Academy is committed to providing engineers with the technical skills required to install a Samsung product efficiently, and to help relay necessary information to users. All courses are designed to provide attendees with the opportunity to develop both theoretical and practical knowledge of Samsung's vast range of equipment and solutions.

Samsung training centres in Europe
Portugal - Lisbon

United Kingdom - Mansfield United Kingdom - Chertsey
Poland - Warsaw The Netherlands - Amsterdam

France - Lyon Spain - Madrid

Italy - Milan

Greece - Athens

Available training modules

Essential courses: Basic commercial training

Advanced courses: Technical training

Advanced courses: Design training

· The product line-up, accessories and available controls
· The unique features of Samsung products
· Installation considerations
110

· How to correctly install and configure a system
· Commissioning: common issues during commissioning and how to resolve any challenges
· Troubleshooting and fault-finding (by use of E-codes)
· Control logic · Case studies

· Understanding customers' needs and offering possible solutions
· DVM Pro 2.0 - Samsung's advanced design tool
· Case studies

Note: the registration process for and availability of training courses may vary per country. Please contact your Samsung representative for more informa-

How to register for training

1

2

Search
To check for available training courses, go to Samsung Business Academy (SBA) via the Samsung Climate Solutions Partner Portal1: partnerhub.samsung.com/climate. Search the online event calendar and select the training course you would like to attend.

Register
After identifying the training course you would like to attend, follow the registration process. Once you have registered successfully you will receive a confirmation e-mail.

3
Get certified
Following confirmation of your registration, we will invite you to one of our training centres. You will be trained by one of our specialised Master Trainers or Product Specialists, and receive a Certificate of Completion.

1 Google Chrome is the recommended web browser for using the Samsung Climate Solutions Partner Portal.

111

Design and Support Design and Support

Design and Support Design and Support

Hydraulic Schematics
112

Project: Casa L (Spain) Project Architecture: ÁBATON
Interior Design: BATAVIA Photography: Carlos Muntadas
113

ClimateHub Split
Application examples
Application 1: Space heating + water heating

Outdoor [ Supply Scope ]
Outdoor unit

Mechanical Room

Indoor

Hot Water Cold Water
Tank Integrated Hydro Unit

Room Controller

45°C

Zone Control

Supply Header

Return Header

Water pump #2

Radiators or Convectors

Tw2_z2 Water pump #1 35°C
Tw2_z1
Balancing Vessel

Supply Header Return Header
Under-Floor Heating Coils

ClimateHub Split
Application examples
Application 2: Hybrid application (backup boiler and solar panel connected)

Outdoor [ Supply Scope ]
Outdoor unit

Mechanical Room

Solar thermal Panel

Indoor

Solar Panel

Solar Pump Hot Water Cold Water
Tank Integrated Hydro Unit

Back up Boiler Operation

Back-up Boiler

Room Controller

45°C

Zone Control Supply Header

Return Header

Water pump #2

Radiators or Convectors

Tw2_z2

Water pump

#1

35°C

Tw2_z1

Balancing Vessel

Supply Header Return Header
Under-Floor Heating Coils

Design and Support Design and Support

114

115

ClimateHub Mono
Application examples
Application 3: Space heating + water heating

Outdoor [ Supply Scope ] Outdoor unit

Mechanical Room

Indoor

Back up Boiler Operation

Back-up Boiler

45°C

Room Controller Zone Control Supply Header
Return Header

Tank Integrated Hydro Unit

Water pump #2

Radiators or Convectors

Tw2_z2

Water

pump #1

35°C

Tw2_z1

Balancing Vessel

Supply Header
Return Header Under-Floor Heating Coils

ClimateHub TDM Plus
Application examples
Application 4: Space heating + water heating/ A2A cooling

Outdoor

[ Supply Scope ]

Outdoor unit

Y joint

Mechanical Room Hot Water Cold Water

Indoor

Room Controller

45°C

Zone Control

Supply Header

Return Header

Tank Integrated Hydro Unit

Water pump #2
Tw2_z2

Radiators or Convectors
Space Heating

Water

pump #1

35°C

Tw2_z1

Balancing Vessel EEV Kit

Supply Header Return Header
Under-Floor Heating Coils
Space Cooling

Design and Support Design and Support

116

117

Notes
118

Notes
119

Notes
120

Notes
121

Notes
122

Notes
123

Notes
124

Notes
125

Notes
126

Notes
127

Learn more about Samsung Climate Solutions at: www.samsung.com/climate
Copyright © 2020 Samsung Electronics Air Conditioner Europe B.V. All rights reserved. Samsung is a registered trademark of Samsung Electronics Co., Ltd. Specifications and designs are subject to change without notice and may include preliminary information. Non-metric weights and measurements are approximate. All data was deemed correct at the time of creation. Samsung is not liable for errors or omissions. Some images may be digitally altered. All brand, product, service names and logos are trademarks and/or registered trademarks of their respective owners and are hereby recognised and acknowledged.
Samsung Electronics Co., Ltd. participates in the Eurovent Certification Programme (ECP) for Air Conditioners (AC), Variable Refrigerant Flow (VRF) and Liquid Chilling Packages Heat Pump (LCP-HP). To check the ongoing validity of certification, please visit: www.eurovent-certification.com
Samsung Electronics Air Conditioner Europe B.V. Evert van de Beekstraat 310, 1118 CX Schiphol P.O. Box 75810, 1118 ZZ Schiphol +31 (0)8 81 41 61 00 The Netherlands


Adobe InDesign 15.0 (Macintosh) Adobe PDF Library 15.0