Installers | Climate Solutions | Samsung Business Ireland
Product Catalogue Eco Heating Systems Introduction Introduction Highlights for 2020-2021 WindFreeTM Samsung extends its WindFreeTM Technology with a completely new WindFreeTM wall-mounted model for its EHS TDM Plus product range. The latest TDM Plus WindFreeTM Deluxe is equipped with WindFreeTM Cooling technology, spreading fresh air gently and evenly through thousands of microholes to create "Still Air" conditions1. TDM Plus WindFreeTM Deluxe NEW WindFreeTM Cooling Wi-Fi Control (optional) Fast Cooling · Equipped with NASA communication protocol. · Available in capacity range 2.2-5.6 kW with optional EEV kit. Wi-Fi Control The new optional Wi-Fi Kit allows users to control up to 16 connectable indoor units via smartphone with the Samsung SmartThings app2. The app checks indoor temperature, outdoor temperature and air quality levels, and then recommends the optimal operating mode. It also offers the option of adding user scenes such as working, walking or resting. The geofencing functionality allows the room temperature to be automatically set at the desired level when the user approaches within a preset distance of 100 m - 150 km from the building. Wi-Fi Kit · Wi-Fi control up to 16 indoor units through Samsung SmartThings. · Welcome Cooling or Heating through geofencing functionality. · Individual energy monitoring for up to 16 outdoor units. · The voice command feature is available through a smartphone with Bixby3. NEW 1 ASHRAE (the American Society of Heating, Refrigeration, and Air-Conditioning Engineers) defines "Still Air" as air currents moving at speeds below 0.15 m/s, with no cold drafts. 2 A Wi-Fi connection and Samsung SmartThings application account are required. Wi-Fi Kit to be ordered separately. Requires iOS 10.0 or later & Android 5.0 or later. 3 Currently Voice control is supported in English (US, UK, Indian), Chinese, Korean, French, German, Italian, Spanish and Portuguese. 2 ClimateHub TDM Plus The Samsung EHS (Eco Heating System) extends the compact and modular Tank Integrated Hydro Unit for TDM Plus in addition to Mono and Split. The ClimateHub with Tank Integrated Hydro Unit saves space, but also reduces the time of installation. With a 2-zone control and advanced functions, energy efficiency and sustainability performance are optimised. Its Time Division Multi Operation means it can supply hot water while also cooling spaces. ClimateHub TDM Plus Floor heating Radiator Hot water Quiet operation · Compact unit size with large water tank (200 L and 260 L). · Intuitive, colour screen touch controller in multiple languages1. · Energy monitoring through touch controller. · 2-zone control, suitable for floor heating and radiators. · SmartThings compatible with optional Wi-Fi kit2. · Backup heater is included to ensure continuous heating. · Solar Power (PV) and Smart Grid ready. · Smooth servicing through the front-mounted service window. Smooth installation Wi-Fi Control (optional) NEW 1 Available languages: English, German, Spanish, French, Italian and Polish. 2 A Wi-Fi connection and Samsung SmartThings application account are required. Wi-Fi Kit to be ordered separately. Requires iOS 10.0 or later & Android 5.0 or later. 3 Introduction Introduction Product overview Mono The EHS Mono can connect to third party equipment such as a Domestic Hot Water (DHW) tank thanks to the Samsung Mono control kit. The Mono Control kit includes a controller, flow sensor, DHW sensor and leaving and return water sensors. Split The EHS Split outdoor unit is connected to a wall-mounted Hydro Unit to combine with a third party Domestic Hot Water (DHW) tank to suit all requirements. When used with the Hydro Unit, the Split enables production of domestic hot water and underfloor heating/ cooling, and heating of radiators. TDM Plus The EHS TDM Plus outdoor unit can connect to a third party Domestic Hot Water Tank (DHW) via a wall-mounted Hydro Unit. TDM Plus with a third party connection offers A2W and A2A home climate comfort. Third party DHW Tank Outdoor Unit Wi-Fi Kit Hot Water 3-Way Valve + Pump Control Kit Mixing Valve + Pump Touch Controller Zone 1 - Radiator Zone 2 - Floor Heating Solar Panel Third party DHW Tank Outdoor Unit 3-Way Valve Hydro Unit Hot Water Wi-Fi Kit Mixing Valve + Pump Touch Controller Zone 1 - Radiator Zone 2 - Floor Heating Solar Panel Outdoor Unit EEV Kit 3-Way Valve Indoor Unit Third party DHW Tank Hot Water Wi-Fi Kit Hydro Unit Mixing Valve + Pump Touch Controller Zone 1 - Radiator Zone 2 - Floor Heating Schematic drawings are for illustrative purposes only. For accurate installation information please consult the technical data book. The selection of the exact product is subject to specific application conditions. Solar panels, underfloor heating panels, radiators and non-integrated components are not provided by Samsung unless specified otherwise. For more detailed product information and technical specifications, please consult the respective product pages of this Product Catalogue. 4 Indoor Units Available Samsung product range Outdoor Units Controls Tank Integrated Wall-Mounted Third party R32 Hydro Unit Hydro Unit DHW Tank Wireless Wired Centralised Wall-Mounted Duct Indoor Units Console R410A Mono Control Kit Wi-Fi Kit Available Samsung product range Outdoor Units Controls Tank Integrated Wall-Mounted Third party R32 Hydro Unit Hydro Unit DHW Tank Wireless Wired Centralised Wall-Mounted Duct Indoor Units Console R410A Mono Control Kit Wi-Fi Kit Available Samsung product range Outdoor Units Controls Tank Integrated Wall-Mounted Third party R32 Hydro Unit Hydro Unit DHW Tank Wireless Wired Centralised Wall-Mounted Duct Console R410A Mono Control Kit Wi-Fi Kit 5 Introduction Introduction Product overview ClimateHub Mono The ClimateHub Mono configuration has a single outdoor unit that includes the hydronic system, making it easy to install and use. The system's potential can be maximised by connecting to Smart Grid or Solar Power (PV). Solar Panel Outdoor Unit Wi-Fi Kit Hot Water Mixing Valve + Pump Touch Controller Tank Integrated Hydro Unit Zone 1 - Radiator Zone 2 - Floor Heating ClimateHub Split The ClimateHub Split configuration has a single outdoor unit, connected by refrigerant pipes to the tank integrated hydro unit. To maximise its potential, the system can be connected to Smart Grid or Solar Power (PV). Outdoor Unit Wi-Fi Kit Hot Water Mixing Valve + Pump Touch Controller Tank Integrated Hydro Unit Zone 1 - Radiator Zone 2 - Floor Heating ClimateHub TDM Plus NEW The TDM Plus system is an `All-In-One' Airto-Water (A2W) and Air-to-Air (A2A) system for a complete home climate solution. It can be used throughout the year for cooling and heating to meet a variety of different user situations and needs. It enables underfloor heating/cooling and radiator heating, as well as offering A2A cooling with various options for air conditioning. The system's potential can be maximised by connecting to Smart Grid or Solar Power (PV). Solar Panel Indoor Unit Outdoor Unit EEV Hot Water Kit Wi-Fi Kit Mixing Valve + Pump Touch Controller Tank Integrated Hydro Unit Zone 1 - Radiator Zone 2 - Floor Heating Schematic drawings are for illustrative purposes only. For accurate installation information please consult the technical data book. The selection of the exact product is subject to specific application conditions. Solar panels, underfloor heating panels, radiators and non-integrated components are not provided by Samsung unless specified otherwise. For more detailed product information and technical specifications, please consult the respective product pages of this Product Catalogue. 6 Project: Atico en el Retiro (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Belén Imaz 7 Introduction Introduction Project: Casa L (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Carlos Muntadas 8 Table of contents Introduction Samsung Climate Solutions at a glance Reference projects in the spotlight Regulations and Standards Certifications NEW Eco Heating Systems (EHS) Product Line-up Selecting the right heating system Nomenclature ClimateHub Features Mono ClimateHub Mono Mono with Third Party DHW Tank Split ClimateHub Split Split with Third Party DHW Tank TDM Plus ClimateHub TDM Plus NEW TDM Plus with Third Party DHW Tank TDM Plus WindFreeTM Deluxe NEW TDM Plus Slim Duct TDM Plus MSP Duct TDM Plus Console Controls Line-up Features Accessories Line-up Design and support Samsung Climate Solutions Partner Portal DVM Pro 2.0 NEW Samsung Climate Solutions Academy Hydraulic Schematics NEW This document may either contain preliminary values or may lack some values that were not yet available at the time of creation. To obtain the latest information, please consult the Samsung Climate Solutions Partner Portal at partnerhub.samsung.com/climate or contact your direct Samsung representative. 9 Introduction Introduction Samsung Climate Solutions at a glance The solutions that we offer At Samsung, we focus on providing cutting-edge innovations in indoor climate comfort and being a leader in intelligent digital connectivity solutions. Cooling Heating Hot water Ventilation Our marketcentric product ranges Residential Light Commercial Commercial Heating Controls Home RAC | FJM CAC | FJM Hotel Retail Office Restaurant Education CAC DVM | HVM | ERV EHS CONTROLS Expert training Marketing platforms Project design Technical support Spare parts 10 Services we provide to empower our partners Corporate and Technology milestones that make us proud 1974 Samsung introduces its first air conditioner. 2014 2005 Samsung Electronics enters the European market for commercial air conditioning. 2015 2017 Samsung Electronics opens Samsung Electronics Air Conditioner Europe B.V. (SEACE) in Amsterdam. 2017 Arrival of the Samsung TDM concept, an all-in-one heat pump solution for heating, cooling and domestic hot water supply. Introduction of the Samsung 360 Cassette, the world's first circular air conditioner that fits seamlessly into the design of any space. Samsung WindFreeTM technology comes onto the market, gently and evenly dispersing fresh air through thousands of micro-holes to limit cold drafts. Our flagship innovations that enrich WindFreeTM Cooling Wi-Fi Control Building Management System people's lives Our European footprint with the locations from which we operate 1 | Samsung Electronics Air Conditioner Europe B.V. 16 | Samsung offices 8 | Warehouses 9 | Training centres 11 Introduction Introduction Samsung reference projects in the spotlight Project Etopia 12 Joseph Daniels CEO Project Etopia Group "A big step in our Samsung partnership is working collaboratively on the heat pump technology. Through this partnership we are able to provide not only heating, cooling and hot water, but we can do this all whilst utilising renewable energy sources. Our class leading pilot project at the BRE innovation park in Watford, UK, uses this system and has been engineered to be more than energy positive. The real game changer for this product specifically is the ability to intelligently control and harmonise it with our smart home system, providing unseen thermal, energy and environmental control with a positive impact on both cost savings and lifestyle." Application Residential Samsung products installed TDM Plus Outdoor Unit Wall-Mounted Hydro Unit SmartThings 13 Introduction Regulations and standards Samsung strives to provide customers with new eco-friendly experiences and lead the way to a sustainable future for the global community through innovative and eco-friendly products and technology. We monitor applicable environmental standards and laws and regulations in the context of our climate solutions operations. Samsung also conducts environmental improvement activities across all product development, production, distribution, use and disposal phases. Energy Label Space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device are subject to Energy labelling EU Regulation No. 811/2013 and Ecodesign EU Regulation No. 813/2013 requirements. As of September 2019, the energy efficiency scale for seasonal space heating ranges from A+++ to D, with A+++ being the most efficient. The water heating energy efficiency scale for the declared load profile for combination heat pumps ranges from to A+ to F, with A+ being the most efficient. The energy labels should provide minimum necessary information such as; supplier's name, product model code, the rated output under three European climates (average, colder and warmer) for medium- and/or low-temperature applications (55 °C and 35 °C), European map displaying the three temperature zones, the sound power level indoors and/or outdoors. In addition, just for combination heat pumps, the energy label should also include a pictogram showing to be able to work only during off-peak hours. Energy Label Heat pump combination heaters Heat pump space heaters Name of Manufacturer Space Heating Energy efficiency class Highest: A+++ Lowest: D Name of model Hot water Name of Manufacturer Space Heating Energy efficiency class Highest: A+ Lowest: F Name of model Energy efficiency class in medium/low temperature applications 55°C/35° Operating noise for indoor and outdoor 14 Nominal capacity in Climate Zones Cold/Average/Warm In heating mode, the EU is divided into three climate zones for calculation and classification purposes. This is to enable calculation of the energy efficiency taking into consideration the actual regional ambient temperatures. Off-peak hour pictogram Operating noise for indoor and outdoor F-Gas regulation The EU aims to reduce the environmental impact of F-gases through the reduction of the CO2 equivalent consumption of HFCs (hydrofluorocarbons). EU regulation 517/2014 prescribes a phase-down of HFCs, where the quantities of HFCs that are placed on the market are gradually reduced through the allocation of quotas by the European Commission. The phase-down targets are expressed in CO2 equivalents (= kg x GWP - Global Warming Potential) and aim to reduce HFC consumption by 79 % in 2030. For new installations of single split air conditioners with a refrigerant charge below 3 kg, the GWP limit is set at 750 starting in 2025. The regulation has been put into force to encourage the industry and its users to transition to refrigerants with a lower GWP. Samsung is accelerating the transition towards lower GWP refrigerants, such as R32, and will continue to invest in environmentally friendly alternatives. % of baseline consumption allowed EU phase-down targets 100 90 80 70 60 50 40 30 20 10 0 2016 2018 2020 2022 Baseline = the average HFC consumption between 2009 and 2012 2024 2026 2028 2030 Reduction comparison between 2015 and 2030 79 % reduction R32 Refrigerant R32 refrigerant contributes to meeting the F-gas regulation targets as described in EU regulation 517/2014. Air conditioners with R32 refrigerant have a Global Warming Potential (GWP) of 675, which is significantly lower than the GWP of R410A (2,088). While refrigerants are an essential part of today's air conditioners, R32 would have a 68 % lower environmental impact1 than R410A if leaked into the atmosphere. It has an Ozone Depletion Potential (ODP) of zero, a high refrigeration capacity and a high thermal conductivity; meaning a high efficiency and a reduction in charging volume. Samsung's single split Residential (RAC), Multi Split (FJM) and Commercial (CAC) product ranges up to 12 kW all feature R32 refrigerant. 1 Comparison between R410A and R32 GWP. Source: European Commission. Global Warming Potential (GWP) 2088 675 Charge ratio 100 % 74 % Effective tCO2eq. 500 R410A R32 15 2088 76 % Introduction Introduction Introduction WEEE: Electronic Waste Samsung adheres to the WEEE (Waste Electrical and Electronic Equipment) Directive. This Directive applies the principles of extended producer responsibility. It stipulates the safe collection, treatment, recycling and environmentally sound disposal of all electrical and electronic equipment. By working with collective recycling schemes in each EU member state Samsung co-finances the take-back and recycling of electronic products. Batteries Samsung has been giving new life to used batteries by funding collection, treatment and recycling by local battery recycling organisations. Packaging Samsung works together with recycling schemes and governmental organisations to collect, separate and reuse all packaging materials at various points in the distribution chain. Many materials can be recycled into new products and recycling helps to save natural resources. Recycling packaging helps to reuse valuable raw materials and to reduce the overall impact on the environment. 16 17 Introduction Introduction Certifications Heat Pump KEYMARK Certificate The Heat Pump KEYMARK is a voluntary, independent, European certification mark (ISO type 5 certification) for all heat pumps, combination heat pumps and hot water heaters (as covered by Ecodesign, EU Regulation 813/2013 and 814/2013). It is based on independent, third-party testing and demonstrates compliance with product requirements as set in the Heat Pump KEYMARK scheme rules and with efficiency requirements as set by Ecodesign. It is aimed at certifying the product performances declared by the manufacturers. The Heat Pump KEYMARK scheme is owned by the European Committee for standardization (CEN). The certificates are granted by independent certification bodies to products fulfilling all requirements of the scheme. Samsung's Eco Heating Systems and the ClimateHub range are certified with a Heat Pump KEYMARK. This certification is recognised in a number of European countries which include France, Germany, the United Kingdom, Slovakia and Czech Republic. Eurovent Certificate Eurovent is globally known for its quality mark `Eurovent Certified Performance' which certifies performance ratings of air-conditioning and refrigeration products according to European and international standards. The `Eurovent Certified Performance' mark indicates that the prescribed quality requirement has been fulfilled and should not require the need to be proven after the customer's decision and after the manufacturer's production process. Eurovent is an accredited third-party certification body. It builds customer confidence by leveling the competitive playing field for all manufacturers and by increasing the integrity and accuracy of the industrial performance ratings. Thus providing trustworthy services to the entire ecosystem. Samsung air conditioning products ranging from the Residential AirConditioning (RAC), Multi Split (FJM), Commercial Air Conditioning (CAC), Digital Variable Multi S (DVM S) and Eco Heating System (EHS) line-up in the `AirtoWater' (A2W) heat pump category are all Eurovent certified. To check the ongoing validity of the Eurovent certified products from Samsung, please visit: www.eurovent-certification.com 18 19 20 Product Line-up Introduction EHS 21 EHS EHS Line-up ClimateHub Outdoor Unit Tank Integrated Hydro Unit Type w Power Model Name Capacity Tank Integrated Hydro Unit (Split) 200 L(1) AE200RNWSEG/ EU 260 L(1) AE260RNWSEG/ EU 260 L(3) AE260RNWSGG/ EU Tank Integrated Hydro Unit (Mono) 200 L(1) AE200RNWMEG/ EU 260 L(1) AE260RNWMEG/ EU 260 L(3) AE260RNWMGG/ EU Tank Integrated Hydro Unit (TDM Plus) 200 L(1) 260 L(1) AE200TNWTEH/ EU AE260TNWTEH/EU R32 Mono 1 Outdoor Unit AE050RXYDEG/EU 5.0 kW AE080RXYDEG/EU 8.0 kW · · · AE120RXYDEG/EU 12.0 kW · · AE160RXYDEG/EU 16.0 kW · · 3 AE080RXYDGG/EU 8.0 kW · AE120RXYDGG/EU 12.0 kW · AE160RXYDGG/EU 16.0 kW · Split 1 AE040RXEDEG/EU 4.0 kW · · AE060RXEDEG/EU 6.0 kW · · AE090RXEDEG/EU 9.0 kW · · 3 AE090RXEDGG/EU 9.0 kW · R410A TDM 1 Outdoor Plus Unit AE044MXTPEH/EU 4.4 kW AE066MXTPEH/EU 6.6 kW · · · · AE090MXTPEH/EU 9.0 kW · · AE120MXTPEH/EU 12.0 kW · AE160MXTPEH/EU 16.0 kW · 3 AE090MXTPGH/EU 9.0 kW · · AE120MXTPGH/EU 12.0 kW · AE160MXTPGH/EU 16.0 kW · TDM Plus Indoor NEW Type Capacity 2.2 kW 2.8 kW 3.6 kW 5.6 kW 7.1 kW 9.0 kW WindFreeTM Deluxe · · · · · Optional Controller v Slim Duct · · · · MSP Duct · · Console · · · · Model Model name Maximum connectible Indoor Units App Voice recognition Welcome Cooling/Heating Automation Add scene Energy monitoring Product dimensions (mm) W x H x D MIM-H04EN Wi-Fi Kit 2.0 16 SmartThings Bixby Geofencing Customised control with a variety of execution rules Easy control throughout customised user mode Individual energy monitoring up to 16 outdoor units 185 x 130 x 29 Model Model name Screen size/type Intuitive user interface Operation Functions Smart connectivity Languages MWR-WW10N MWR-WW10JN NEW IN Q1'21 MWR-WW10KN NEW IN Q2'21 Product dimensions (mm) W x H x D MWR-WW10*N Touch Controller 4.3'' Color LCD display Dynamic navigation with simplified buttons Heating / Cooling/ Auto / DHW Smart Grid Ready / PV Ready / 2-zone Control / Energy consumption monitor / Energy saving SmartThings via optional Wi-Fi Kit 2.0 English, German, French, Italian, Spanish, Polish (EN, DE, FR, IT, ES, PL) English, Portuguese, Dutch, Greek, Czech, Slovak (EN, PT, NL, EL, CS, SK) English, Finnish, Swedish, Norwegian, Danish, Lithuanian (EN, FI, SV, NO, DA, LT) 120x120x19 22 23 EHS EHS Line-up EHS with Third Party DHW Tank Mono with Third Party DHW Tank w Type Power Model Name Capacity R32 Outdoor Unit Mono 1 3 AE050RXYDEG/EU AE080RXYDEG/EU AE120RXYDEG/EU AE160RXYDEG/EU AE080RXYDGG/EU AE120RXYDGG/EU AE160RXYDGG/EU 5.0 kW 8.0 kW 12.0 kW 16.0 kW 8.0 kW 12.0 kW 16.0 kW Outdoor Unit Mono Control Kit Mono MIM-E03CN · · · · · · · DHW Tank (third party) Split with Third Party DHW Tank w Type Power Model Name Capacity R32 Split 1 Outdoor Unit 3 AE040RXEDEG/EU AE060RXEDEG/EU AE090RXEDEG/EU AE090RXEDGG/EU 4.0 kW 6.0 kW 9.0 kW 9.0 kW R410A Split 1 Outdoor Unit 3 AE120JXEDEH/EU AE160JXEDEH/EU AE120JXEDGH/EU AE160JXEDGH/EU 12.0 kW 16.0 kW 12.0 kW 16.0 kW 24 Outdoor Unit Split(1) AE090RNYDEG/EU · · · · AE160JNYDEH/EU · · Wall-Mounted Hydro Unit Wall-Mounted Hydro Unit DHW Tank (third party) Split(3) AE090RNYDGG/EU · AE160JNYDGH/EU · · TDM Plus with Third Party DHW Tank TDM Plus with Third Party DHW Tank w Type Power Model Name Capacity R410A TDM Plus Split 1 Outdoor Unit 3 AE044MXTPEH/EU AE066MXTPEH/EU AE090MXTPEH/EU AE120MXTPEH/EU AE160MXTPEH/EU AE090MXTPGH/EU AE120MXTPGH/EU AE160MXTPGH/EU 4.4 kW 6.6 kW 9.0 kW 12.0 kW 16.0 kW 9.0 kW 12.0 kW 16.0 kW Outdoor Unit Wall-Mounted Hydro Unit DHW Tank (third party) AE090MNYDEH/EU Split(1) Wall-Mounted Hydro Unit Split(3) AE160MNYDEH/EU AE090MNYDGH/EU AE160MNYDGH/EU · · · · · · · · 25 EHS EHS Selecting the right heating system ClimateHub Main Function Comfort Feature Smart Install A2W Cooling A2W Heating A2W Domestic Hot Water A2A Cooling Maximum Allowable Indoor unit Connections Colour Display Low Noise1 Outing Schedule / Holiday Mode Emergency Operation Wi-Fi Kit SmartThings Wired Remote Controller Zone Controller 4 Mixing Valve 3-Way Valve 4 2-Way Valve Thermostat Control PV Integrated Smart Grid Ready Energy Consumption Monitoring Set FSV with SD Card Smart Checking Mono / Split · · · · · · · · · ·2 · · · · · · · · · · TDM Plus (R410A) · · · · up to 7 Indoor unit · · · · · · ·2 · · · · · · · · · · 26 Third Party DHW Tank solutions Mono · · · · · · · · · ·2 ·3 · ·4 · · · · · Split Split (R410A) TDM Plus (R410A) · · · · · · · · · · up to 7 Indoor unit · · · · · · · · · · · · · · · · · · · ·3 ·3 · · · ·4 ·4 ·4 · · · · · · · · · · · · 1 Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 2 Wired Remote Controller to be ordered separately. 3 In combination with an external room sensor. 4 Not provided by Samsung. 27 EHS EHS Nomenclature Indoor units AE 260 R N W S E G 1 2 3 4 5 6 7 8 1 Classification AE 2 Capacity J M 3 Year R T 4 Product Type N A/X J L 5 Product Notation M W Y D P 6 Feature M S T E 7 Rating Voltage G G 8 Mode H EHS x1/10 kW (3 digits) x Litre (3 digits) 2015 2017 2019 2020 Indoor Unit (NASA) RAC Wall-Mounted Console LSP Duct MSP Duct Tank Integrated Hydro Unit Wall-Mounted Hydro Unit Standard Mono Split TDM Plus 1, 220~240 V, 50 Hz 3, 380~415 V, 50 Hz R32 Heat Pump R410A Heat Pump Outdoor units AE 090 R X E D E G 1 2 3 4 5 6 7 8 1 Classification AE 2 Capacity J 3 Year M R 4 Product Type X E 5 Product Notation T Y D 6 Feature P E 7 Rating Voltage G G 8 Mode H EHS x1/10 kW (3 digits) 2015 2017 2019 Outdoor Unit (NASA) Split TDM Plus Mono Standard 1, 220~240 V, 50 Hz 3, 380~415 V, 50 Hz R32 Heat Pump R410A Heat Pump 28 29 ClimateHub Features EHS EHS Compact Design The Samsung ClimateHub solution is built around a compact tank integrated hydro unit, with a large volume domestic hot water tank of either 200 L or 260 L. The compact and modular design makes for straightforward kitchen or utility room integration. Smart Grid Ready and PV Enabled A Smart Grid efficiently integrates the behaviour and actions of all the users connected to it. Smart Grid readiness enables users to benefit from an economically efficient and sustainable power supply. Thanks to the PV (Photovoltaic or `solar' energy) enabled feature, the system can be connected to solar panels, saving energy through renewable sources.1 1 The usage of the PV Enabled feature requires additional third party equipment to be installed. Smooth Servicing With a conveniently placed servicing window and intuitive servicing options available through the use of a Micro SD card or the Samsung S-Checker Mobile App, troubleshooting and start-up can be done easily from the front of the unit.1 1 Please refer to your direct Samsung contact person for more information about the S-Checker Mobile App. 30 Intuitive Control Samsung's touch controller comes equipped with multiple language options and bright colour display enabling temperature settings, energy monitoring, summer time setting and quick error monitoring.1 1 The image shows an application example and is for illustrative purposes only. Please always check latest information for understanding availability of language versions. Quiet Operation In order to meet increasingly strict sound level requirements, Samsung ClimateHub allows to reduce noise levels using the 4-Step Quiet Operation mode1. Subject to specific models and particular operation conditions, it is possible to achieve levels as low as 35 dB(A)2. 1 ClimateHub Mono and TDM Plus has a 3-Step Quiet Operation mode. 2 Sound pressure levels are subject to execution and operating conditions. Smart Connectivity The touch controller enables users to manage different temperature settings per zone, meaning high-temperature radiators and low-temperature floor heating can be utilised efficiently. With the optional Wi-Fi Kit, different aspects of the system, including controlling and monitoring up to 16 indoor units through the Samsung SmartThings App.1 1 A Wi-Fi connection and Samsung SmartThings application account are required. Wi-Fi Kit to be ordered separately. Requires iOS 10.0 or later & Android 5.0 or later. 31 EHS EHS Comfortably cool. Surprisingly still. Samsung introduces a completely new WindFreeTM wallmounted model for its EHS TDM Plus product range. Equipped with WindFreeTM technology, the micro-holes spread fresh air gently and evenly to enhance indoor comfort for ultimate indoor climate convenience. Step 1 The front panel opens, and Fast Cooling mode cools the room quickly from corner to corner. Step 2 The set temperature is reached in Fast Cooling mode, and the front panel closes. Step 3 WindFreeTM mode spreads fresh air uniformly through thousands of micro-holes. WindFreeTM Cooling Easy Control Easy Installation WindFreeTM technology enhances your indoor comfort by using thousands of micro-holes to disperse fresh air uniformly without any unpleasant blasts of cold wind. In WindFreeTM mode, air is spread softly and silently, creating a `Still Air' environment1 that provides you total well-being day and night. Samsung WindFreeTM is designed to make life easier. It can be operated via wired or wireless controllers that feature advanced functions for a convenient control of indoor climates. Temperatures can also be managed remotely using the SmartThings App2.. Turning it on and off, selecting the cooling mode or scheduling its operation is just one touch away. The WindFreeTM Deluxe can be easily mounted through its snap-fit design and roller bracket. The installation process is simplified to fit in effortlessly to the exact position. With an easy-to-remove front grill and a separate cover panel, installers can minimise product damage and reduce service time. 1 ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers) defines "Still Air" as air currents at speeds below 0.15m/s which lacks the presence of cold drafts. 2 A Wi-Fi connection and Samsung SmartThings application account are required. Wi-Fi Kit to be ordered separately. Requires iOS 10.0 or later & Android 5.0 or later.. 32 Wi-Fi Kit 2.0 Mobile Remote Control and Monitoring Solution You can remotely control and monitor up to 16 indoor units with ease by using the SmartThings App2. Enhanced Convenience The voice command feature is available through a smartphone with Bixby1. Temperatures can also be managed remotely anytime, and anywhere, using the SmartThings app2. Personalised Climate Environment Operates in your preferred mode according to the user settings. The geofencing functionality allows the room temperature to be automatically set at the desired level when the user approaches within a preset distance from the building. The Wi-Fi-Kit (optional) is mandatory to enable a multi-device experience interoperable with smart appliances. Energy Usage Monitoring3 Energy usage can be monitored daily, weekly and monthly at a glance. Provides ease of installation Allows for easy setup possible for up to 16 indoor units. 1 App Voice Recognition: Bixby voice is an intelligent voice assistant that helps you use the device more conveniently. 1 Currently Voice control is supported in English (US, UK, Indian), Chinese, Korean, French, German, Italian, Spanish and Portuguese. 2 A Wi-Fi connection and Samsung SmartThings application account are required. Wi-Fi Kit to be ordered separately. Requires iOS 10.0 or later & Android 5.0 or later. 3 Current and daily, weekly or monthly energy usage of the outdoor unit is reference data calculated for information and reference purposes only. Energy monitoring Allows you to view your daily, weekly, and monthly energy usage at a glance Energy service Allows you to quickly check the energy usage of multiple devices in your home Automation Operates in your preferred mode according to the user settings Welcome cooling/heating Pre-cooling and pre-heating before your arrival at home 33 EHS Mono Mono 34 Project: Atico en el Retiro (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Belén Imaz 35 Mono Mono Specifications ClimateHub Mono · Integrated solution for heating and domestic hot water · Compact unit size with large water tank (200 L & 260 L) · Intuitive, colour screen touch controller in multiple languages · Energy monitoring through touch controller · Smooth servicing through the front-mounted service window · PV and Smart Grid ready · 2-zone Control, suitable for floor heating and radiators · SCOP rating of A+++* · SmartThings compatible with optional Wi-Fi kit · Backup heater is included to ensure continuous heating System Tank Integrated Hydro Unit Outdoor Unit Indoor Unit Outdoor Unit Controller Operation Nominal Capacity Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ Power Input (Nominal) Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ COP (Nominal Heating) A7/W35¹ / A7/W55² EER (Nominal Cooling) A35/W18¹ SCOP LWT 35°C/ 55°C Seasonal Space Heating enr.efficiency s LWT 35°C/ 55°C Seasonal Space Heating Eff. class * LWT 35°C/ 55°C Current MCA MFA Water Flow Rate Leaving Water Temperature³ Low / Medium temperature Heating Cooling Functions Smart Grid Ready / PV Enabled 3-Step Quiet Mode 2-zone Control Power Supply Water Tank Volume Declared Load Profile Average water heating efficiency wh Average Energy Efficiency Class Sound Heater Piping Dimensions Sound Pressure4 Sound Power Back-up heater Capacity Water Pipe (Space Heating) Water pipe (DHW) Net Weight Heating Std Cooling Std Heating Std Default (Option) Inlet/ Outlet Inlet/ Outlet Power Supply Compressor Base Heater Sound Net Dimensions (WxHxD) Type Capacity Sound Pressure4 Dimensions Refrigerant Sound Power Net Weight Net Dimensions (WxHxD) Type Factory Charging Heating Std Cooling Std Heating Std Piping Operation Water Pipe (Space Heating) Ambient Temperature Inlet/ Outlet Heating Cooling DHW kW kW kW kW W/W W/W W/W ETA% - A A l/min , #, V, Hz litres L/XL ETA% dB(A) dB(A) dB(A) kW , mm , mm kg mm , V, Hz kW dB(A) dB(A) dB(A) kg mm tCOe kg , mm AE200RNWMEG/EU AE050RXYDEG/EU MWR-WW10N AE200RNWMEG/EU AE080RXYDEG/EU MWR-WW10N AE200RNWMEG/EU AE120RXYDEG/EU MWR-WW10N 5.0/4.3 5.0 1.03/1.52 1.14 4.85/2.83 4.39 4.46/3.2 175/ 125 8.0/7.1 7.5 1.77/2.53 1.90 4.52/2.81 3.95 4.44/3.23 175/ 126 12.0/11.3 12.0 2.65/3.73 2.77 4.53/3.03 4.33 4.69/3.51 185/ 138 A+++ / A++ 16.00 20.00 14.4/7.8 15~65 5~25 1, 2, 220~240 V, 50 Hz 200 L 115 A 26 26 40 2 (4/6) 28/28 22/22 130.0 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 45 45 61 58.5 880 x 798 x 310 0.68 1.00 28/28 -25~35 10~46 -25~43 A+++ / A++ 22.00 27.50 23.1/12.8 15~65 5~25 1, 2, 220~240 V, 50 Hz 200 L 115 A 26 26 40 2 (4/6) 28/28 22/22 130.0 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15 48 48 63 76.0 940 x 998 x 330 R32 (Fluorinated greenhouse gas, GWP=675) 0.78 1.15 28/28 -25~35 10~46 -25~43 A+++ / A++ 28.00 35.00 34.6/20.4 15~65 5~25 1, 2, 220~240 V, 50 Hz 200 L 110 A 30 30 44 2 (4/6) 28/28 22/22 130.0 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15 50 50 64 110.0 940 x 1,420 x 330 1.49 2.20 28/28 -25~35 10~46 -25~43 36 Accessories Touch Controller MWR-WW10N Touch Controller MCM-A300N DMS2.5 MIM-D01AN Wi-Fi Kit MIM-H04EN External Room Sensor MRW-TA Backup Heater (4/6kW) MHC-*00FE AE200RNWMEG/EU AE160RXYDEG/EU MWR-WW10N 16.0/15.0 14.0 3.62/5.18 3.28 4.42/2.90 4.27 4.48/3.53 176/ 138 A+++ / A++ 32.00 40.00 46.2/27.1 15~65 5~25 1, 2, 220~240 V, 50 Hz 200 L 110 A 30 30 44 2 (4/6) 28/28 22/22 130.0 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15 52 54 66 110.0 940 x 1,420 x 330 1.49 2.20 28/28 -25~35 10~46 -25~43 AE260RNWMEG/EU AE080RXYDEG/EU MWR-WW10N AE260RNWMEG/EU AE120RXYDEG/EU MWR-WW10N 8.0/7.1 7.5 1.77/2.53 1.90 4.52/2.81 3.95 4.44/3.23 175/ 126 12.0/11.3 12.0 2.65/3.73 2.77 4.53/3.03 4.33 4.69/3.51 185/ 138 A+++ / A++ A+++ / A++ 22.00 27.50 28.00 35.00 23.1/12.8 34.6/20.4 15~65 15~65 5~25 5~25 1, 2, 220~240 V, 50 Hz 260 XL 123 1, 2, 220~240 V, 50 Hz 260 XL 117 A A 26 30 26 30 40 44 2 (4/6) 2 (4/6) 28/28 28/28 22/22 22/22 140.0 140.0 595 x 1,800 x 700 595 x 1,800 x 700 1, 220~240 V, 50 Hz 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15 48 BLDC Twin Rotary 0.15 50 48 50 63 64 76.0 110.0 940 x 998 x 330 940 x 1,420 x 330 R32 (Fluorinated greenhouse gas, GWP=675) 0.78 1.49 1.15 2.20 28/28 28/28 -25~35 -25~35 10~46 10~46 -25~43 -25~43 AE260RNWMEG/EU AE160RXYDEG/EU MWR-WW10N 16.0/15.0 14.0 3.62/5.18 3.28 4.42/2.90 4.27 4.48/3.53 176/ 138 A+++ / A++ 32.00 40.00 46.2/27.1 15~65 5~25 1, 2, 220~240 V, 50 Hz 260 XL 117 A 30 30 44 2 (4/6) 28/28 22/22 140.0 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15 52 54 66 110.0 940 x 1,420 x 330 1.49 2.20 28/28 -25~35 10~46 -25~43 *A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++ 1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB]. 2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB]. 365°C down to +10°C (max. 60°C down to -5°C) 4Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 37 Mono Mono Specifications ClimateHub Mono (Continued) System Tank Integrated Hydro Unit Outdoor Unit Indoor Unit Outdoor Unit Controller Operation Nominal Capacity Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ Power Input (Nominal) Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ COP (Nominal Heating) A7/W35¹ / A7/W55² EER (Nominal Cooling) A35/W18¹ SCOP LWT 35°C/ 55°C Seasonal Space Heating enr.efficiency s LWT 35°C/ 55°C Seasonal Space Heating Eff. class * LWT 35°C/ 55°C Current MCA MFA Water Flow Rate Low / Medium temperature Leaving Water Temperature³ Heating Cooling Functions Smart Grid Ready / PV Enabled 3-Step Quiet Mode 2-zone Control Power Supply Water Tank Volume Declared Load Profile Average water heating efficiency wh Average Energy Efficiency Class Sound Sound Pressure4 Heating Std Heater Piping Sound Power Back-up heater Capacity Water Pipe (Space Heating) Water pipe (DHW) Cooling Std Heating Std Default (Option) Inlet/ Outlet Inlet/ Outlet Dimensions Net Weight Power Supply Compressor Base Heater Sound Net Dimensions (WxHxD) Type Capacity Sound Pressure4 Dimensions Sound Power Net Weight Heating Std Cooling Std Heating Std Net Dimensions (WxHxD) Refrigherant Type Factory Charging Piping Operation Water Pipe (Space Heating) Ambient Temperature Inlet/ Outlet Heating Cooling DHW kW kW kW kW W/W W/W W/W ETA% - A A l/min , #, V, Hz litres L/XL ETA% dB(A) dB(A) dB(A) kW , mm , mm kg mm , V, Hz kW dB(A) dB(A) dB(A) kg mm tCOe kg , mm AE260RNWMGG/EU AE080RXYDGG/EU MWR-WW10N AE260RNWMGG/EU AE120RXYDGG/EU MWR-WW10N AE260RNWMGG/EU AE160RXYDGG/EU MWR-WW10N 8.0/7.1 7.5 1.77/2.53 1.90 4.52/2.81 3.95 4.44/3.23 175/ 126 12.0/11.3 12.0 2.65/3.73 2.77 4.53/3.03 4.33 4.69/3.51 185/ 138 16.0/15.0 14.0 3.62/5.18 3.28 4.42/2.90 4.27 4.48/3.53 176/ 138 A+++ / A++ 10.00 16.10 23.1/12.8 15~65 5~25 3, 4, 380~415 V, 50 Hz 260 XL 123 A 26 26 40 6 28/28 22/22 140.0 595 x 1,800 x 700 3, 380~415 V, 50 Hz BLDC Twin Rotary 0.15 48 48 63 75.0 940 x 998 x 330 0.78 1.15 28/28 -25~35 10~46 -25~43 A+++ / A++ 10.00 16.10 34.6/20.4 15~65 5~25 3, 4, 380~415 V, 50 Hz 260 XL 117 A 30 30 44 6 28/28 22/22 140.0 595 x 1,800 x 700 3, 380~415 V, 50 Hz BLDC Twin Rotary 0.15 50 50 64 111.0 940 x 1,420 x 330 R32 (Fluorinated greenhouse gas, GWP=675) 1.49 2.20 28/28 -25~35 10~46 -25~43 A+++ / A++ 12.00 16.10 46.2/27.1 15~65 5~25 3, 4, 380~415 V, 50 Hz 260 XL 117 A 30 30 44 6 28/28 22/22 140.0 595 x 1,800 x 700 3, 380~415 V, 50 Hz BLDC Twin Rotary 0.15 52 54 66 111.0 940 x 1,420 x 330 1.49 2.20 28/28 -25~35 10~46 -25~43 38 *A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++ 1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB]. 2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB]. 365°C down to +10°C (max. 60°C down to -5°C) 4Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. Project: Atico en el Retiro (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Belén Imaz 39 Mono Mono Specifications Mono with Third Party DHW Tank · Intuitive, colour screen touch controller in multiple languages · Energy monitoring through touch controller · PV and Smart Grid ready · 2-zone Control, suitable for floor heating and radiators · SmartThings compatible with optional Wi-Fi kit System Outdoor Unit Operation Functions Power Supply Compressor Base Heater Sound Dimensions Piping Refrigerant Outdoor Unit Control Kit Nominal Capacity Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ Power Input (Nominal) Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ COP (Nominal Heating) A7/W35¹ / A7/W55² EER (Nominal Cooling) A35/W18¹ Seasonal space heating enr.efficiency s LWT 35°C/ 55°C Seasonal space heating eff. class** LWT 35°C/ 55°C Current MCA Leaving Water Temperature2 MFA Heating Cooling Smart Grid Ready / PV Enabled 3-Step Quiet Mode 2-zone Control Type Capacity Sound Pressure4 Sound Power Net Weight Net Dimensions (WxHxD) Water Pipe Type Factory Charging Heating Std Cooling Std Heating Std Inlet/ Outlet Operation Ambient Temperature Heating Cooling DHW kW kW kW kW W/W W/W ETA% - A A , V, Hz kW dB(A) dB(A) dB(A) kg mm , mm tCOe kg AE050RXYDEG/EU MIM-E03CN AE080RXYDEG/EU MIM-E03CN AE120RXYDEG/EU MIM-E03CN 5.0/4.3 5.0 1.03/1.52 1.14 4.85/2.83 4.39 175/ 125 8.0/7.1 7.5 1.77/2.53 1.90 4.52/2.81 3.95 175/ 126 12.0/11.3 12.0 2.65/3.73 2.77 4.55/3.03 4.33 185/ 138 A+++ / A++ 16.00 20.00 15~65 5~25 1, 220~240 V, 50 Hz BLDC Twin Rotary 45 45 61 58.5 880 x 798 x 310 25/ 25 0.68 1.00 -25~35 10~46 -25~43 A+++ / A++ 22.00 27.50 15~65 5~25 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15 48 48 63 76.0 940 x 998 x 330 25/ 25 R32 (Fluorinated greenhouse gas, GWP=675) 0.78 1.15 -25~35 10~46 -25~43 A+++ / A++ 28.00 35.00 15~65 5~25 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15 50 50 64 110.0 940 x 1,420 x 330 25/ 25 1.49 2.20 -25~35 10~46 -25~43 40 Accessories Mono Control Kit MIM-E03CN Touch Controller MCM-A300N DMS2.5 MIM-D01AN Wi-Fi Kit MIM-H04EN External Room Sensor MRW-TA AE160RXYDEG/EU MIM-E03CN 16.0/15.0 14.0 3.62/5.18 3.28 4.42/2.90 4.27 176/ 138 A+++ / A++ 32.00 40.00 15~65 5~25 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15 52 54 66 110.0 940 x 1,420 x 330 25/ 25 1.49 2.20 -25~35 10~46 -25~43 AE080RXYDGG/EU MIM-E03CN AE120RXYDGG/EU MIM-E03CN 8.0/7.1 7.5 1.77/2.53 1.90 4.52/2.81 3.95 175/ 126 12.0/11.3 12.0 2.65/3.73 2.77 4.53/3.03 4.33 185/ 138 A+++ / A++ A+++ / A++ 10.00 10.00 16.10 15~65 16.10 15~65 5~25 5~25 3, 380~415 V, 50 Hz 3, 380~415 V, 50 Hz BLDC Twin Rotary 0.15 48 BLDC Twin Rotary 0.15 50 48 50 63 64 75.0 111.0 940 x 998 x 330 940 x 1,420 x 330 25/ 25 25/ 25 R32 (Fluorinated greenhouse gas, GWP=675) 0.78 1.49 1.15 2.20 -25~35 -25~35 10~46 10~46 -25~43 -25~43 AE160RXYDGG/EU MIM-E03CN 16.0/15.0 14.0 3.62/5.18 3.28 4.42/2.90 4.27 176/ 138 A+++ / A++ 12.00 16.10 15~65 5~25 3, 380~415 V, 50 Hz BLDC Twin Rotary 0.15 52 54 66 111.0 940 x 1,420 x 330 25/ 25 1.49 2.20 -25~35 10~46 -25~43 *A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++ 1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB]. 2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB]. 365°C down to +10°C (max. 60°C down to -5°C) 4Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 41 Dimensional Drawings Mono Tank Integrated Hydro Unit AE200/260RNW**G/EU Mono Outdoor AE050RXYDEG/EU 880 310 Mono 364 798 Mono NO 1 2 3 4 5 6 7 8 9 42 Name Space heating Inlet Space heating Outlet DHW Inlet Secondary water return DHW Outlet Heat Pump In Heat Pump Out T/P v/v Drain Holes AE200RNWMEG/EU Description AE260RNWM*G/EU ø28 ø28 ø28 ø28 ø22 ø22 N/A ø22 ø22 ø22 ø28 ø28 ø28 ø28 Female PT 1/2" Female PT 1/2" (Option) Connect with the provided drain plug 497 227 NO 1 2 3 Name Description Water Pipe(Out) BSPP male 1" Water Pipe(In) BSPP male 1" Power & Communication Wiring Conduit Holes 364 43 Dimensional Drawings Mono Outdoor AE080RXYD*G/EU 514 245 Mono Outdoor AE120/160RXYD*G/EU Mono Mono 940 385 998 NO 1 2 3 Name Description Water Pipe(Out) BSPP male 1" Water Pipe(In) BSPP male 1" Power & Communication Wiring Conduit Holes 44 330 360 385 NO 1 2 3 Name Description Water Pipe(Out) BSPP male 1" Water Pipe(In) BSPP male 1" Power & Communication Wiring Conduit Holes 45 Mono Mono Dimensional Drawings Mono Control Kit MIM-E03CN NO 1 Name Conduit Holes for Wiring (Rubber) 46 Project: Casa L (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Carlos Muntadas 47 Mono Split Split 48 Project: Casa L (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Carlos Muntadas 49 Split Split Specifications ClimateHub Split · Integrated solution for heating and domestic hot water · 4-step quiet operation mode (down to 35 db(A)*) · Compact unit size with large water tank (200 L & 260 L) System Tank Integrated Hydro Unit Outdoor Unit 50 Indoor Unit Outdoor Unit Controller Operation Nominal Capacity Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ Power Input (Nominal) Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ COP (Nominal Heating) A7/W35¹ / A7/W55² EER (Nominal Cooling) A35/W18¹ SCOP LWT 35°C/ 55°C Seasonal space heating enr.efficiency s LWT 35°C/ 55°C Average Seasonal space heating eff. class ** LWT 35°C/ 55°C Current MCA MFA Leaving Water Temperature³ Heating Cooling Functions Smart Grid Ready / PV Enabled 4-Step Quiet Mode 2-zone Control Power Supply Water Tank Volume Declared Load Profile Average water heating efficiency wh Average Energy Efficiency Class kW kW kW kW W/W W/W W/W ETA% - A A , #, V, Hz litres L/XL ETA% Heater Sound Piping Dimensions Power Supply Compressor Base Heater Sound Dimensions Piping Operation Back-up heater Capacity Default (Option) kW Sound Pressure4 Heating Std dB(A) Cooling Std dB(A) Sound Power Heating Std dB(A) Water pipe (Space Heating) Inlet/Outlet , mm Water pipe (DHW) Inlet/Outlet , mm Net Weight kg Net Dimensions (WxHxD) mm , V, Hz Type - Capacity kW Sound Pressure4 Heating Std dB(A) Cooling Std dB(A) Night Mode dB(A) Sound Power Heating Std dB(A) Net Weight kg Net Dimensions (WxHxD) mm Refrigerant Type - Factory Charging tCOe kg Piping Connections Liquid Pipe , mm (inch) Gas Pipe , mm (inch) Piping length (ODU-IDU)5 Max.[Equiv.] m Level difference (IDU-IDU)5 Max. m Ambient Temperature Heating Cooling DHW AE200RNWSEG/EU AE040RXEDEG/EU MWR-WW10N AE200RNWSEG/EU AE060RXEDEG/EU MWR-WW10N AE200RNWSEG/EU AE090RXEDEG/EU MWR-WW10N 4.4/3.9 5.0 0.85/1.32 1.09 5.20/2.95 4.59 4.58/3.25 180/ 127 6.0/5.2 6.5 1.22/1.81 1.47 4.92/2.87 4.42 4.58/3.31 180/ 129 9.0/8.0 8.7 1.87/2.73 2.11 4.81/2.93 4.12 4.45/3.24 175/ 127 A+++ / A++ 16.00 20.00 15~65 5~25 1, 2, 220~240 V, 50 Hz 200 L 120 A+ 2 (4/6) 26 26 40 28/28 22/22 136 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 44 46 <35 58 46.5 880 x 638 x 310 0.81 1.2 6.35 (1/4") 15.88 (5/8") 30.00 20.00 -25~35 10~46 -25~43 A+++ / A++ 16.00 20.00 15~65 5~25 1, 2, 220~240 V, 50 Hz 200 L 120 A+ 2 (4/6) 26 26 40 28/28 22/22 136 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 47 47 35 60 46.5 880 x 638 x 310 R32 (Fluorinated greenhouse gas, GWP=675) 0.81 1.2 6.35 (1/4") 15.88 (5/8") 30.00 20.00 -25~35 10~46 -25~43 A+++ / A++ 22.00 27.50 15~65 5~25 1, 2, 220~240 V, 50 Hz 200 L 119 A+ 2 (4/6) 26 26 40 28/28 22/22 136 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 0.15 49 49 35 64 73.0 940 x 998 x 330 0.95 1.4 6.35 (1/4") 15.88 (5/8") 35.00 20.00 -25~35 10~46 -25~43 Accessories Touch Controller MWR-WW10N Touch Controller MCM-A300N DMS2.5 MIM-D01AN Wi-Fi Kit MIM-H04EN External Room Sensor MRW-TA Backup Heater (4/6kW) MHC-*00FE AE260RNWSEG/EU AE040RXEDEG/EU MWR-WW10N 4.4/3.9 5.0 0.85/1.32 1.09 5.20/2.95 4.59 4.58/3.25 180/ 127 A+++ / A++ 16.00 20.00 15~65 5~25 1, 2, 220~240 V, 50 Hz 260 XL 123 A+ 2 (4/6) 26 26 40 28/28 22/22 146.0 595 x 1,800 x 700 1, 220~240 V, 50 Hz BLDC Twin Rotary 44 46 <35 58 46.5 880 x 638 x 310 0.81 1.2 6.35 (1/4") 15.88 (5/8") 30.00 20.00 -25~35 10~46 -25~43 AE260RNWSEG/EU AE060RXEDEG/EU MWR-WW10N AE260RNWSEG/EU AE090RXEDEG/EU MWR-WW10N 6.0/5.2 6.5 1.22/1.81 1.47 4.92/2.87 4.42 4.58/3.31 180/ 129 9.0/8.0 8.7 1.87/2.73 2.11 4.81/2.93 4.12 4.45/3.24 175/ 127 A+++ / A++ A+++ / A++ 16.00 22.00 20.00 27.50 15~65 15~65 5~25 5~25 1, 2, 220~240 V, 50 Hz 1, 2, 220~240 V, 50 Hz 260 260 XL XL 123 123 A+ A+ 2 (4/6) 2 (4/6) 26 26 26 26 40 40 28/28 28/28 22/22 22/22 146.0 146.0 595 x 1,800 x 700 595 x 1,800 x 700 1, 220~240 V, 50 Hz 1, 220~240 V, 50 Hz BLDC Twin Rotary BLDC Twin Rotary - 0.15 47 49 47 49 35 35 60 64 46.5 73.0 880 x 638 x 310 940 x 998 x 330 R32 (Fluorinated greenhouse gas, GWP=675) 0.81 0.95 1.2 1.4 6.35 (1/4") 6.35 (1/4") 15.88 (5/8") 15.88 (5/8") 30.00 35.00 20.00 20.00 -25~35 -25~35 10~46 10~46 -25~43 -25~43 AE260RNWSGG/EU AE090RXEDGG/EU MWR-WW10N 9.0/8.0 8.7 1.87/2.73 2.11 4.81/2.93 4.12 4.45/3.24 175/ 127 A+++ / A++ 10.00 16.10 15~65 5~25 3, 4, 380~415 V, 50 Hz 260 XL 123 A+ 6 26 26 40 28/28 22/22 146.0 595 x 1,800 x 700 3, 380~415 V, 50 Hz BLDC Twin Rotary 0.15 49 49 35 64 72.0 940 x 998 x 330 0.95 1.4 6.35 (1/4") 15.88 (5/8") 35.00 20.00 -25~35 10~46 -25~43 *35dB(A) is only applicable for 6kW and 9kW outdoor units down to +4°C stated in 3 m distance in an anechoic environment. **A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++ 1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB]. 2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB]. 365°C down to +10°C (max. 60°C down to -5°C) 4Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 5 ODU : Outdoor Unit, IDU : Indoor Unit 51 Split Split Specifications Split with Third Party DHW Tank · Connectable with R32 Split Outdoor Unit in combination of third party Tank · Competible with thermostats, solar panels and back-up boilers · Intuitive, colour screen touch controller in multiple languages · Energy monitoring through touch controller · PV and Smart Grid ready · 2-zone Control, suitable for floor heating and radiators · SmartThings compatible with optional Wi-Fi kit System Wall-Mounted Hydro Unit Outdoor unit Indoor Unit Outdoor Unit Operation Nominal Capacity Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ Power Input (Nominal) Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ COP (Nominal Heating) A7/W35¹ EER (Nominal Cooling) A35/W18¹ Seasonal space heating enr.efficiency s LWT 35°C/ 55°C Seasonal Space Heating Eff. Class LWT 35°C/ 55°C Current MCA MFA Leaving Water Temperature2 Heating Cooling Functions Smart Grid Ready / PV Enabled 4-Step Quiet Mode 2-zone Control Power Supply Heater Back-up heater Capacity Default (Option) Sound Sound Pressure³ Heating Std Cooling Std Sound Power Heating Std Dimensions Net Weight Net Dimensions (WxHxD) Piping Water pipe Inlet/Outlet Compressor Type Base Heater Capacity Sound Sound Pressure3 Heating Std Cooling Std Sound Power Heating Std Dimensions Net Weight Net Dimensions (WxHxD) Refrigerant Type Factory Charging Piping Piping Connections Operation Piping length (ODU-IDU)4 Level difference (IDU-IDU)4 Chargeless Length Ambient Temperature Liquid Pipe Gas Pipe Max.[Equiv.] Max. Heating Cooling DHW kW kW kW kW W/W W/W ETA% - A A , V, Hz kW dB(A) dB(A) dB(A) kg mm , inch kW dB(A) dB(A) dB(A) kg mm tCOe kg , mm (inch) , mm (inch) m m , mm AE090RNYDEG/EU AE040RXEDEG/EU AE090RNYDEG/EU AE060RXEDEG/EU AE090RNYDEG/EU AE090RXEDEG/EU 4.4/3.9 5.0 0.85/1.32 1.09 5.20/2.95 4.59 180/ 127 6.0/5.2 6.5 1.22/1.81 1.47 4.92/2.87 4.42 180/ 129 9.0/8.0 8.7 1.87/2.73 2.11 4.81/2.93 4.12 175/ 127 A+++ / A++ 16.00 20.00 15~65 5~25 1, 2, 220~240 V, 50 Hz 4 26 26 40 45,0 510 x 850 x 315 1+1/4'' BLDC Twin Rotary 44 46 58 46.5 880 x 638 x 310 A+++ / A++ 16.00 20.00 15~65 5~25 1, 2, 220~240 V, 50 Hz 4 26 26 40 45,0 510 x 850 x 315 1+1/4'' BLDC Twin Rotary 47 47 60 46.5 880 x 638 x 310 A+++ / A++ 22.00 27.50 15~65 5~25 1, 2, 220~240 V, 50 Hz 4 26 26 40 45,0 510 x 850 x 315 1+1/4'' BLDC Twin Rotary 0.15 49 49 64 73.0 940 x 998 x 330 R32 (Fluorinated greenhouse gas, GWP=675) 1.2 0.81 6.35 (1/4'') 15.88 (5/8'') 30 20 15 -25~35 10~46 -25~43 1.2 0.81 6.35 (1/4'') 15.88 (5/8'') 30 20 15 -25~35 10~46 -25~43 1.4 0.95 6.35 (1/4'') 15.88 (5/8'') 35 20 15 -25~35 10~46 -25~43 52 Accessories Touch Controller (included) MWR-WW10N Touch Controller MCM-A300N DMS2.5 MIM-D01AN Wi-Fi Kit MIM-H04EN External Room Sensor MRW-TA AE090RNYDGG/EU AE090RXEDGG/EU 9.0/8.0 8.7 1.87/2.73 2.11 4.81/2.93 4.12 175/127 A+++ / A++ 10.00 16.10 15~65 5~25 3, 2, 380~415 V, 50 Hz 6 26 26 40 46.5 510 x 850 x 315 1+1/4'' BLDC Twin Rotary 0.15 49 49 64 72.0 940 x 998 x 330 R32 (Fluorinated greenhouse gas, GWP=675) 1.4 0.95 6.35 (1/4'') 15.88 (5/8'') 35 20 15 -25~35 10~46 -25~43 **A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++ 1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB]. 2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB]. 3Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 4 ODU : Outdoor Unit, IDU : Indoor Unit 53 Specifications Split with Third Party DHW Tank (R410A) · Connectable with R410A Split Outdoor Unit in combination of third party Tank · Competible with room thermostats, solar pumps, 2- or 3-way valves and back-up boilers Accessories EHS Controller (included) MWR-WW00N Touch Controller MCM-A300N DMS2.5 MIM-D01AN Wi-Fi Kit MIM-H04EN External Room Sensor MRW-TA Split Split System Wall-Mounted Hydro Unit Outdoor unit Indoor Unit Outdoor Unit Operation Nominal Capacity Power Input (Nominal) COP (Nominal Heating) A7/W35¹ EER (Nominal Cooling) A35/W18¹ Seasonal space heating enr.efficiency s LWT 35°C/ 55°C Seasonal Space Heating Eff. Class LWT 35°C/ 55°C Current Leaving Water Temperature Functions Smart Grid Ready/PV Enabled 3-Step Quiet Mode 2-zone Control² Power Supply Heater Capacity Sound Sound Pressure3 Piping Dimensions Compressor Base Heater Sound Sound Power Water pipe Net Weight Net Dimensions (WxHxD) Type Capacity Sound Pressure3 Dimensions Refrigerant Sound Power Net Weight Net Dimensions (WxHxD) Type Heating A7/W35¹ Cooling A35/W18¹ Heating A7/W35¹ Cooling A35/W18¹ MCA MFA Heating Cooling Heating Std Cooling Std Heating Std Inlet/Outlet Heating Std Cooling Std Heating Std Factory Charging Piping Piping Connections Operation Piping length (ODU-IDU)4 Level difference (IDU-IDU)4 Chargeless Length Ambient Temperature Liquid Pipe Gas Pipe Max.[Equiv.] Max. Heating Cooling DHW kW kW kW kW W/W W/W ETA% - A A , V, Hz kW dB(A) dB(A) dB(A) , inch kg mm kW dB(A) dB(A) dB(A) kg mm tCOe kg , mm (inch) , mm (inch) m m , mm AE160JNYDEH/EU AE120JXEDEH/EU AE160JNYDGH/EU AE120JXEDGH/EU AE160JNYDEH/EU AE160JXEDEH/EU 12.0 12.0 2.59 3.10 4.63 3.87 184/ 107 12.0 12.0 2.59 3.10 4.63 3.87 184/ 107 16.0 15.0 3.76 4.14 4.26 3.62 173/ 115 A+++ / A+ A+++ / A+ A++ / A+ 28.00 35.00 25~55 5~25 - 1, 2, 220~240 V, 50 Hz 6 33 33 47 1+1/4'' 45.0 510 x 850 x 315 BLDC Twin Rotary 0.15 50 50 64 100.0 940 x 1,420 x 330 10.00 16.10 25~55 5~25 - 3, 2, 380~415 V, 50 Hz 6 33 33 47 1+1/4'' 46.5 510 x 850 x 315 BLDC Twin Rotary 0.15 50 50 64 101.5 940 x 1,420 x 330 32.00 37.50 25~55 5~25 - 1, 2, 220~240 V, 50 Hz 6 33 33 47 1+1/4'' 45.0 510 x 850 x 315 BLDC Twin Rotary 0.15 52 54 66 100.0 940 x 1,420 x 330 R410A (Fluorinated greenhouse gas, GWP=2,088) 6.22 6.22 6.22 2.98 2.98 2.98 9.52 (3/8'') 9.52 (3/8'') 9.52 (3/8'') 15.88 (5/8'') 50 30 15 -25~35 10~46 -25~43 15.88 (5/8'') 50 30 15 -25~35 10~46 -25~43 15.88 (5/8'') 50 30 15 -25~35 10~46 -25~43 AE160JNYDGH/EU AE160JXEDGH/EU 16.0 15.0 3.76 4.14 4.26 3.62 173/ 115 A++ / A+ 12.00 16.10 25~55 5~25 - 3, 2, 380~415 V, 50 Hz 6 33 33 47 1+1/4'' 46.5 510 x 850 x 315 BLDC Twin Rotary 0.15 52 54 66 101.5 940 x 1,420 x 330 R410A (Fluorinated greenhouse gas, GWP=2,088) 6.22 2.98 9.52 (3/8'') 15.88 (5/8'') 50 30 15 -25~35 10~46 -25~43 54 1 A2W Conditions : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB]. 2 Not provided by Samsung. 3 Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 4 ODU: Outdoor Unit, IDU: Indoor Unit 55 Dimensional Drawings Split Tank Integrated Hydro Unit AE200/260RNW**G/EU Split Outdoor AE040/060RXEDEG/EU Split Split NO 1 2 3 4 5 6 7 8 9 56 Name Space heating Inlet Space heating Outlet DHW Inlet Secondary water return DHW Outlet Refrigerant liquid pipe Refrigerant gas pipe T/P v/v Drain Holes AE200RNWSEG/EU Description AE260RNWS*G/EU Ø28 Ø28 Ø28 Ø28 Ø22 Ø22 N/A Ø22 Ø22 Ø22 Ø9.52 Ø9.52 Ø15.88 Ø15.88 Female PT 1/2" Female PT 1/2" (Option) Connect with the provided drain plug NO 1 2 3 Name Refrigerant liquid pipe Refrigerant gas pipe Drain holes Description 6.35(1/4) 15.88(5/8) Connect with the provided drain plug. 57 Split Dimensional Drawings Split Outdoor AE090RXED*G/EU NO 1 2 3 4 5 6 Name Refrigerant gas pipe Refrigerant liquid pipe Piping intake knockout hole Power wiring conduit Communication wiring conduit Drain Hole 58 Description 6.35(1/4) 15.88(5/8) Front / Side / Rear / Bottom Front / Side / Rear , 34 [1-3/8] Front / Side / Rear , 22 [7/8] Connect with the provided drain plug Split Outdoor AE120/160JXED*H/EU 12mm 330 943 940 300 1420 655 3-TOP 621 NO 1 2 3 4 Name Refrigerant gas pipe Refrigerant liquid pipe Drain Hole Power wiring conduit Description 15.88 9.52 Connect with the provided drain plug N/A 59 570 1107 Split Split Split Dimensional Drawings Split Wall-Mounted Hydro Unit AE090RNYD*G/EU, AE160JNYD*H/EU NO 1 2 3 4 60 Name Refrigerant gas pipe Refrigerant liquid pipe Water pipe inlet/outlet Drain Hose Connector Project: Atico en el Retiro (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Belén Imaz 61 62 TDM Plus Split TDM Plus 63 TDM Plus TDM Plus Specifications ClimateHub TDM Plus (R410A) · 'All in one' air-to-water and air-to-air system · PV and Smart Grid ready · Compact unit size with large water tank (200L & 260L) · 2-zone control, suitable for floor heating and radiators · Intuitive, colour screen touch controller in multiple languages · SCOP rating of A+++** · Energy monitoring through touch controller · SmartThings compatible with optional Wi-Fi kit · Smooth servicing through the front-mounted service window · Backup heater is included to ensure continuous heating System Tank Integrated Hydro Unit Outdoor Unit Indoor Unit Outdoor Unit Controller Operation Nominal Capacity Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ Power Input (Nominal) Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ COP (Nominal Heating) A7/W35¹ / A7/W55² EER (Nominal Cooling) A35/W18¹ SCOP LWT 35°C/ 55°C Seasonal space heating enr.efficiency s LWT 35°C/ 55°C Average Seasonal space heating eff. class ** LWT 35°C/ 55°C Current MCA MFA Maximum allowable IDU5 connections (Hydro A2W unit not included) Max. number of IDU5 Total capacity Min. (Cooling) Total capacity Min. (Cooling) Leaving Water Temperature³ Heating Cooling Functions Smart Grid Ready / PV Enabled 3-Step Quiet Mode 2-zone Control Power Supply Water Tank Volume Declared Load Profile Average water heating efficiency wh Average Energy Efficiency Class Heater Sound Piping Dimensions Power Supply Compressor Base Heater Sound Dimensions Refrigerant Back-up heater Capacity Sound Pressure4 Sound Power Water pipe (Space Heating) Net Weight Net Dimensions (WxHxD) Default (Option) Heating Std Cooling Std Heating Std Inlet/Outlet Type Capacity Sound Pressure4 Sound Power Net Weight Net Dimensions (WxHxD) Type Factory Charging Heating Std Cooling Std Heating Std Piping Operation Piping Connections Piping length (ODU-IDU)5 Level difference (IDU-IDU)5 Chargeless length Ambient Temperature A2W Ambient Temperature A2A Liquid Pipe Gas Pipe Max.[Equiv.] Max. Heating Cooling DHW Heating Cooling kW kW kW kW W/W W/W W/W ETA% - A A EA kW kW , #, V, Hz litres L/XL ETA% kW dB(A) dB(A) dB(A) , inch kg mm , V, Hz kW dB(A) dB(A) dB(A) kg mm Type tCOe kg , mm (inch) , mm (inch) m m m 64 AE200TNWTEH/EU AE044MXTPEH/EU MWR-WW10N AE200TNWTEH/EU AE066MXTPEH/EU MWR-WW10N 4.4/ 3.8 5.1 0.93/ 1.37 1.03 4.73/ 2.80 4.95 4.41/ 2.83 173/ 110 6.6/ 4.8 6.7 1.47/ 1.85 1.48 4.49/ 2.59 4.53 4.41/ 2.96 173/ 115 A++ / A+ A++ / A+ 18.00 25.00 2 2.20 4.40 15~55 5~25 20.00 25.00 3 3.30 6.60 15~55 5~25 1, 2, 220~240 V, 50 Hz 200 L 115 1, 2, 220~240 V, 50 Hz 200 L 115 A+ A+ 2 (4/6) 2 (4/6) 29 29 29 29 43 43 1+1/4'' 1+1/4'' 137 137 595 x 1,800 x 700 595 x 1,800 x 700 1, 2, 220~240 V, 50 Hz 1, 2, 220~240 V, 50 Hz Rotary Comp Rotary Comp - - 47 48 46 47 65 67 61.0 61.0 880 x 793 x 310 880 x 793 x 310 R410A (Fluorinated greenhouse gas, GWP=2,088) 5.43 5.43 2.6 2.6 9.52 (3/8'') 9.52 (3/8'') 15.88 (5/8'') 15.88 (5/8'') 30 30 20 20 10 10 -25~35 -25~35 10~46 10~46 -25~43 -25~43 -25~24 -25~24 10~46 10~46 Accessories Touch Controller MWR-WW10N Touch Controller MCM-A300N DMS2.5 MIM-D01AN Wi-Fi Kit MIM-H04EN External Room Sensor MRW-TA Backup Heater (4/6kW) MHC-*00FE AE200TNWTEH/EU AE090MXTPEH/EU MWR-WW10N 9.0/ 7.7 8.0 2.12/ 2.82 1.85 4.25/ 2.72 4.32 4.42/ 3.01 174/ 117 A++ / A+ 22.00 27.50 4 4.50 9.00 15~55 5~25 1, 2, 220~240 V, 50 Hz 200 L 115 A+ 2 (4/6) 29 29 43 1+1/4'' 137 595 x 1,800 x 700 1, 2, 220~240 V, 50 Hz Rotary Comp 51 50 69 74.0 940 x 998 x 330 5.01 2.4 9.52 (3/8'') 15.88 (5/8'') 30 20 10 -25~35 10~46 -25~43 -25~24 10~46 AE200TNWTEH/EU AE090MXTPGH/EU MWR-WW10N AE260TNWTEH/EU AE044MXTPEH/EU MWR-WW10N 9.0/ 7.7 8.0 2.12/ 2.82 1.86 4.25/ 2.69 4.30 4.44/ 2.86 175/ 111 4.4/ 3.8 5.1 0.93/ 1.37 1.03 4.73/ 2.80 4.95 4.41/ 2.83 173/ 110 A+++ / A+ A++ / A+ 10.00 16.10 4 4.50 9.00 15~55 5~25 18.00 25.00 2 2.20 4.40 15~55 5~25 1, 2, 220~240 V, 50 Hz 200 L 115 1, 2, 220~240 V, 50 Hz 260 XL 105 A+ A 2 (4/6) 2 (4/6) 29 29 29 29 43 43 1+1/4'' 1+1/4'' 137 147 595 x 1,800 x 700 595 x 1,800 x 700 3, 4, 380~415 V, 50 Hz 1, 2, 220~240 V, 50 Hz Rotary Comp Rotary Comp - - 51 47 50 46 69 65 76.0 61.0 940 x 998 x 330 880 x 793 x 310 R410A (Fluorinated greenhouse gas, GWP=2,088) 5.01 5.43 2.4 2.6 9.52 (3/8'') 9.52 (3/8'') 15.88 (5/8'') 15.88 (5/8'') 30 30 20 20 10 10 -25~35 -25~35 10~46 10~46 -25~43 -25~43 -25~24 -25~24 10~46 10~46 AE260TNWTEH/EU AE066MXTPEH/EU MWR-WW10N 6.6/ 4.8 6.7 1.47/ 1.85 1.48 4.49/ 2.59 4.53 4.41/ 2.96 173/ 115 A++ / A+ 20.00 25.00 3 3.30 6.60 15~55 5~25 1, 2, 220~240 V, 50 Hz 260 XL 105 A 2 (4/6) 29 29 43 1+1/4'' 147 595 x 1,800 x 700 1, 2, 220~240 V, 50 Hz Rotary Comp 48 47 67 61.0 880 x 793 x 310 5.43 2.6 9.52 (3/8'') 15.88 (5/8'') 30 20 10 -25~35 10~46 -25~43 -25~24 10~46 *35dB(A) is only applicable for 6kW and 9kW outdoor units down to +4°C stated in 3 m distance in an anechoic environment. **A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++ 1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB]. 2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB]. 365°C down to +10°C (max. 60°C down to -5°C) 4Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 5 ODU : Outdoor Unit, IDU : Indoor Unit 65 TDM Plus TDM Plus Specifications ClimateHub TDM Plus (R410A) (Continued) System Tank Integrated Hydro Unit Outdoor Unit Indoor Unit Outdoor Unit Controller Operation Nominal Capacity Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ Power Input (Nominal) Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ COP (Nominal Heating) A7/W35¹ / A7/W55² EER (Nominal Cooling) A35/W18¹ SCOP LWT 35°C/ 55°C Seasonal space heating enr.efficiency s LWT 35°C/ 55°C Average Seasonal space heating eff. class ** LWT 35°C/ 55°C Current Maximum allowable IDU5 connections (Hydro A2Wunit not included) Leaving Water Temperature³ MCA MFA Max. number of IDU5 Total capacity Min. (Cooling) Total capacity Min. (Cooling) Heating Cooling Functions Smart Grid Ready / PV Enabled 3-Step Quiet Mode 2-zone Control Power Supply Water Tank Volume Declared Load Profile Average water heating efficiency wh Average Energy Efficiency Class Heater Sound Piping Dimensions Power Supply Compressor Base Heater Sound Dimensions Refrigerant Back-up heater Capacity Sound Pressure4 Sound Power Water pipe (Space Heating) Net Weight Net Dimensions (WxHxD) Default (Option) Heating Std Cooling Std Heating Std Inlet/Outlet Type Capacity Sound Pressure4 Sound Power Net Weight Net Dimensions (WxHxD) Type Factory Charging Heating Std Cooling Std Heating Std Piping Operation Piping Connections Piping length (ODU-IDU)5 Level difference (IDU-IDU)5 Chargeless length Ambient Temperature A2W Ambient Temperature A2A Liquid Pipe Gas Pipe Max.[Equiv.] Max. Heating Cooling DHW Heating Cooling kW kW kW kW W/W W/W W/W ETA% - A A EA kW kW , #, V, Hz litres L/XL ETA% - kW dB(A) dB(A) dB(A) , inch kg mm , V, Hz kW dB(A) dB(A) dB(A) kg mm Type tCOe kg , mm (inch) , mm (inch) m m m 66 AE260TNWTEH/EU AE090MXTPEH/EU MWR-WW10N AE260TNWTEH/EU AE120MXTPEH/EU MWR-WW10N 9.0/ 7.7 8.0 2.12/ 2.82 1.85 4.25/ 2.72 4.32 4.42/ 3.01 174/ 117 12.0/ 10.7 12.0 2.72/ 3.91 2.90 4.41/ 2.74 4.14 4.65/ 2.92 183/114 A++ / A+ A+++ / A+ 22.00 27.50 4 4.50 9.00 15~55 28.00 35.00 5 6.00 12.10 15~55 5~25 5~25 1, 2, 220~240 V, 50 Hz 260 XL 105 1, 2, 220~240 V, 50 Hz 260 XL 95 A A 2 (4/6) 2 (4/6) 29 29 29 29 43 47 1+1/4'' 1+1/4'' 147 147 595 x 1,800 x 700 595 x 1,800 x 700 1, 2, 220~240 V, 50 Hz 1, 2, 220~240 V, 50 Hz Rotary Comp Rotary Comp - - 51 52 50 51 69 70 74.0 107.0 940 x 998 x 330 940 x 1,420 x 330 R410A (Fluorinated greenhouse gas, GWP=2,088) 5.01 7.31 2.4 3.5 9.52 (3/8'') 9.52 (3/8'') 15.88 (5/8'') 15.88 (5/8'') 30 70 20 30 10 10 -25~35 -25~35 10~46 10~46 -25~43 -25~43 -25~24 -25~24 10~46 10~46 Accessories Touch Controller MWR-WW10N Touch Controller MCM-A300N DMS2.5 MIM-D01AN Wi-Fi Kit MIM-H04EN External Room Sensor MRW-TA Backup Heater (4/6kW) MHC-*00FE AE260TNWTEH/EU AE160MXTPEH/EU MWR-WW10N 16.0/ 14.6 14.5 3.95/ 5.32 3.84 4.05/2.74 3.78 4.63/3.06 182/ 119 A+++ / A+ 32.00 40.00 7 7.70 15.40 15~55 5~25 1, 2, 220~240 V, 50 Hz 260 XL 95 A 2 (4/6) 29 29 47 1+1/4'' 147 595 x 1,800 x 700 1, 2, 220~240 V, 50 Hz Rotary Comp 55 54 73 107.0 940 x 1,420 x 330 7.31 3.5 9.52 (3/8'') 15.88 (5/8'') 70 30 10 -25~35 10~46 -25~43 -25~24 10~46 AE260TNWTEH/EU AE090MXTPGH/EU MWR-WW10N AE260TNWTEH/EU AE120MXTPGH/EU MWR-WW10N 9.0/ 7.7 8.0 2.12/ 2.82 1.86 4.25/2.69 4.30 4.44/2.86 175/ 111 12.0/ 10.7 12.0 2.72/ 3.91 2.90 4.41/ 2.74 4.14 4.65/2.92 183/ 114 A+++ / A+ A+++ / A+ 10.00 16.10 4 4.50 9.00 15~55 10.00 16.10 5 6.00 12.10 15~55 5~25 5~25 1, 2, 220~240 V, 50 Hz 260 XL 105 1, 2, 220~240 V, 50 Hz 260 XL 95 A A 2 (4/6) 2 (4/6) 29 29 29 29 43 47 1+1/4'' 1+1/4'' 147 147 595 x 1,800 x 700 595 x 1,800 x 700 3, 4, 380~415 V, 50 Hz 3, 4, 380~415 V, 50 Hz Rotary Comp Rotary Comp - - 51 52 50 51 69 70 76.0 107.0 940 x 998 x 330 940 x 1,420 x 330 R410A (Fluorinated greenhouse gas, GWP=2,088) 5.01 7.31 2.4 3.5 9.52 (3/8'') 9.52 (3/8'') 15.88 (5/8'') 15.88 (5/8'') 30 70 20 30 10 10 -25~35 -25~35 10~46 10~46 -25~43 -25~43 -25~24 -25~24 10~46 10~46 AE260TNWTEH/EU AE160MXTPGH/EU MWR-WW10N 16.0/ 14.6 14.5 3.95/ 5.32 3.84 4.05/2.74 3.78 4.63/ 3.06 182/ 119 A+++ / A+ 12.00 16.10 7 7.70 15.40 15~55 5~25 1, 2, 220~240 V, 50 Hz 260 XL 95 A 2 (4/6) 29 29 47 1+1/4'' 147 595 x 1,800 x 700 3, 4, 380~415 V, 50 Hz Rotary Comp 55 54 73 107.0 940 x 1,420 x 330 7.31 3.5 9.52 (3/8'') 15.88 (5/8'') 70 30 10 -25~35 10~46 -25~43 -25~24 10~46 *35dB(A) is only applicable for 6kW and 9kW outdoor units down to +4°C stated in 3 m distance in an anechoic environment. **A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++ 1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB]. 2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB]. 365°C down to +10°C (max. 60°C down to -5°C) 4Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 5 ODU : Outdoor Unit, IDU : Indoor Unit 67 TDM Plus TDM Plus Specifications TDM Plus with Third party tank connection (R410A) · 'All in one' air-to-water and air-to-air system · Connectable with R410A Split ODU in combination of third party Tank · Compatible with room thermostats, solar pumps, 2- or 3-way valves and back-up boilers Indoor Unit Outdoor Unit System Wall-Mounted Hydro Unit Outdoor Unit Operation Operation Nominal Capacity Heating A7/W35¹/ A7/W55² Cooling A35/W18¹ Power Input (Nominal) Heating A7/W35¹ / A7/W55² Cooling A35/W18¹ COP (Nominal Heating) A7/W35¹ kW kW kW kW W/W EER (Nominal Cooling) A35/W18¹ W/W SCOP LWT 35°C/ 55°C W/W Seasonal space heating enr.efficiency s LWT 35°C/ 55°C ETA% Seasonal Space Heating Eff. Class LWT 35°C/ 55°C Current MCA A MFA A Maximum Allowable IDU6 Connections (Hydro A2W Unit Not Included) Max. Number EA of IDU6 Total Capacity kW Min. (Cooling) Total Capacity kW Min. (Cooling) Leaving Water Temperature3 Heating Cooling Functions Smart Grid Ready/ PV Enabled 3-Step Quiet Mode 2-zone Control4 Power Supply , #, V, Hz Expansion Vessel litres Heater Sound Piping Back-up heater Capacity Sound Pressure5 Sound Power Water pipe Std Std Inlet/Outlet kW dB(A) dB(A) , inch Dimensions Net Weight kg Net Dimensions (WxHxD) Power Supply Compressor Type Base Heater Capacity Sound Sound Pressure5 Heating Std mm , V, Hz kW dB(A) Dimensions Sound Power Net Weight Net Dimensions (WxHxD) Cooling Std Heating Std dB(A) dB(A) kg mm Refrigerant Type - Factory Charging tCOe Piping Piping Connections Liquid Pipe Gas Pipe Piping Length (ODU-IDU)5 Level Difference (IDU-IDU)5 Chargeless Length Ambient Temperature A2W Max.[Equiv.] Max. Heating Cooling kg , mm (inch) , mm (inch) m m m DHW Ambient Temperature A2A Heating Cooling AE090MNYDEH/EU AE044MXTPEH/EU 4.4/ 3.8 5.1 0.93/ 1.37 1.03 4.73/2.80 4.95 4.41/ 2.83 173/ 110 A++ / A+ 18 25.0 2 2.2 4.4 15~55 (H/P : 25~55) 5~25 - 1, 2, 220~240 V, 50 Hz 8 4 31 48 1+1/4'' 45.5 510 x 850 x 315 1, 2, 220~240 V, 50 Hz Rotary Comp 47 46 65 61 880 x 793 x 310 5.43 2.6 9.52 (3/8'') 15.88 (5/8'') 30 20 10 -25~35 10~46 -25~43 -25~24 10~46 AE090MNYDEH/EU AE066MXTPEH/EU AE090MNYDEH/EU AE090MXTPEH/EU 6.6/ 4.8 6.7 1.47/ 1.85 1.48 4.49/2.59 4.53 4.41/2.96 173/ 115 A++ / A+ 20 25.0 3 9.0/ 7.7 8.0 2.12/ 2.82 1.85 4.25/2.72 4.32 4.42/ 3.01 174/ 117 A++ / A+ 22 27.5 4 3.3 4.5 6.6 9.0 15~55 (H/P : 25~55) 5~25 - 15~55 (H/P : 25~55) 5~25 - 1, 2, 220~240 V, 50 Hz 1, 2, 220~240 V, 50 Hz 8 8 4 4 31 31 48 48 1+1/4'' 1+1/4'' 45.5 45.5 510 x 850 x 315 510 x 850 x 315 1, 2, 220~240 V, 50 Hz 1, 2, 220~240 V, 50 Hz Rotary Comp Rotary Comp - - 48 51 47 50 67 69 61 74 880 x 793 x 310 940 x 998 x 330 R410A (Fluorinated greenhouse gas, GWP=2,088) 5.43 5.01 2.6 2.4 9.52 (3/8'') 9.52 (3/8'') 15.88 (5/8'') 30 20 10 -25~35 10~46 -25~43 -25~24 10~46 15.88 (5/8'') 30 20 10 -25~35 10~46 -25~43 -25~24 10~46 AE090MNYDGH/EU AE090MXTPGH/EU 9.0/ 7.7 8.0 2.12/ 2.82 1.86 4.25/2.69 4.30 4.44/ 2.86 175/ 111 A+++ / A+ 10 16.1 4 4.5 9.0 15~55 (H/P : 25~55) 5~25 - 3, 4, 380~415 V, 50 Hz 8 6 31 48 1+1/4'' 46.5 510 x 850 x 315 3, 4, 380~415 V, 50 Hz Rotary Comp 51 50 69 76 940 x 998 x 330 5.01 2.4 9.52 (3/8'') 15.88 (5/8'') 30 20 10 -25~35 10~46 -25~43 -25~24 10~46 68 EHS Controller (included) MWR-WW00N Touch Controller MCM-A300N Accessories DMS2.5 MIM-D01AN Wi-Fi Kit MIM-H04EN External Room Sensor MRW-TA AE160MNYDEH/EU AE120MXTPEH/EU 12.0/ 10.7 12.0 2.72/ 3.91 2.90 4.41/2.74 4.14 4.65/ 2.92 183/ 114 A+++ / A+ 28 35.0 5 6.0 12.1 15~55 (H/P : 25~55) 5~25 - 1, 2, 220~240 V, 50 Hz 8 6 38 55 1+1/4'' 46.5 510 x 850 x 315 1, 2, 220~240 V, 50 Hz Rotary Comp 52 51 70 107 940 x 1,420 x 330 7.31 3.5 9.52 (3/8'') 15.88 (5/8'') 70 30 10 -25~35 10~46 -25~43 -25~24 10~46 AE160MNYDGH/EU AE120MXTPGH/EU AE160MNYDEH/EU AE160MXTPEH/EU 12.0/ 10.7 12.0 2.72/ 3.91 2.90 4.41/2.74 4.14 4.65/ 2.92 183/ 114 A+++ / A+ 10 16.1 5 16.0/ 14.6 14.5 3.95/ 5.32 3.84 4.05/2.74 3.78 4.63/ 3.06 182/ 119 A+++ / A+ 32 40.0 7 6.0 7.7 12.1 15.4 15~55 (H/P : 25~55) 5~25 - 15~55 (H/P : 25~55) 5~25 - 3, 4, 380~415 V, 50 Hz 1, 2, 220~240 V, 50 Hz 8 8 6 6 38 38 55 55 1+1/4'' 1+1/4'' 46.5 46.5 510 x 850 x 315 510 x 850 x 315 3, 4, 380~415 V, 50 Hz 1, 2, 220~240 V, 50 Hz Rotary Comp Rotary Comp - - 52 55 51 54 70 73 107 107 940 x 1,420 x 330 940 x 1,420 x 330 R410A (Fluorinated greenhouse gas, GWP=2,088) 7.31 7.31 3.5 3.5 9.52 (3/8'') 9.52 (3/8'') 15.88 (5/8'') 70 30 10 -25~35 10~46 -25~43 -25~24 10~46 15.88 (5/8'') 70 30 10 -25~35 10~46 -25~43 -25~24 10~46 AE160MNYDGH/EU AE160MXTPGH/EU 16.0/ 14.6 14.5 3.95/ 5.32 3.84 4.05/2.74 3.78 4.63/ 3.06 182/ 119 A+++ / A+ 12 16.1 7 7.7 15.4 15~55 (H/P : 25~55) 5~25 - 3, 4, 380~415 V, 50 Hz 8 6 38 55 1+1/4'' 46.5 510 x 850 x 315 3, 4, 380~415 V, 50 Hz Rotary Comp 55 54 73 107 940 x 1,420 x 330 7.31 3.5 9.52 (3/8'') 15.88 (5/8'') 70 30 10 -25~35 10~46 -25~43 -25~24 10~46 *35dB(A) is only applicable for 6kW and 9kW outdoor units down to +4°C stated in 3 m distance in an anechoic environment. **A+++ energy label is available according to EU No. 811/2013 label classification 2019, on a scale from D to A+++ 1 A2W Condition : (Heating) Water In/Out 30/35, Outdoor Air 7[DB]/6[WB]; (Cooling) Water In/Out 23/18, Outdoor Air 35[DB]. 2A2W Condition : (Heating) Water In/Out 47/55, Outdoor Air 7[DB]/6[WB]. 365°C down to +10°C (max. 60°C down to -5°C) 4Not provided by Samsung. 5Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 6 ODU : Outdoor Unit, IDU : Indoor Unit 69 TDM Plus TDM Plus Specifications TDM Plus WindFreeTM Deluxe · Three-step cooling: Fast Cooling mode · WindFreeTM Cooling Mode · Wi-Fi Control with SmartThings and Bixby voice controls · Equipped with NASA communication protocol · Equipped with Easy Filter Plus Power Supply Capacity Power Input (Nominal) Current Input (Nominal) Fan Fan motor Piping Connections Wiring connections Refrigerant Sound Dimensions Functions Air Flow Air Purification Operating Mode Other Functions Type Model Name Cooling Heating Cooling Heating Cooling Heating Type Quantity Air Flow Rate H/M/L Type Output xn Liquid Pipe Gas Pipe For power supply below 20m/over 20m (min) Communication (min) Type Control Method 1 Sound Pressure H/M/L/WF 2 Sound Power Net Weight Net Dimensions (WxHxD) , #, V, Hz kW kW W W A A EA m³/min l/s W , mm(inch) , mm(inch) mm² mm² dB(A) dB(A) kg mm WindFreeTM Cooling Air Direction Control (Up/Down) Air Direction Control (Left/Right) Auto Fan speed Tri-Care Filter Easy Filter Plus Auto Clean (Self Cleaning) 2 Step Cooling AI Auto Comfort with Wi-Fi & MDS (direct/indirect) AI Auto Comfort with Wi-Fi Auto Mode (without Wi-Fi) Fast Cooling Good Sleep Eco Dehumidifi cation Fan Quiet Samsung SmartThings MDS (Motion Detect Sensor) Indoor Temp. Display Display On/Off 88 Display Beep On/Off Auto Changeover Auto Restart TDM Plus WindFreeTM Deluxe AE022TNXDEH/EU 1, 2, 220~240 V, 50 Hz 2.20 2.50 24.0 24.0 0.16 0.16 Cross flow Fan 1 5.7/5.0/4.5 95.0/83.3/75.0 BLDC 27x1 6.35 (1/4) 12.7 (1/2) 1.5/2.5 0.75 EEV NOT INCLUDED 34/32/30/27 51 8.50 820 x 299 x 215 TDM Plus WindFreeTM Deluxe AE028TNXDEH/EU 1, 2, 220~240 V, 50 Hz 2.80 3.20 30.0 30.0 0.20 0.20 Cross flow Fan 1 8.5/7.7/6.9 141.7/128.3/115.0 BLDC 27x1 6.35 (1/4) 12.7 (1/2) 1.5/2.5 0.75 R410A (Fluorinated greenhouse gas, GWP=2,088) EEV NOT INCLUDED 34/33/32/26 52 9.00 820 x 299 x 215 TDM Plus WindFreeTM Deluxe AE036TNXDEH/EU 1, 2, 220~240 V, 50 Hz 3.60 4.00 37.0 37.0 0.25 0.25 Cross flow Fan 1 10.3/9.1/8.3 171.7/151.7/138.3 BLDC 27x1 6.35 (1/4) 12.7 (1/2) 1.5/2.5 0.75 EEV NOT INCLUDED 40/36/34/26 56 9.00 820 x 299 x 215 Auto Auto - - - Auto Auto - - - Auto Auto - - - 70 Accessories 1-room EEV Kit MEV-E**SA 2/3 Room EEV Kit MXD-E**K***A Wireless Remote Controller (included) AR-EH03E Touch Controller MWR-SH11N Wired Remote Controller MWR-WE13N DMS2.5 MIM-D01AN Wi-Fi Kit MIM-H04EN TDM Plus WindFreeTM Deluxe AE056TNXDEH/EU TDM Plus WindFreeTM Deluxe AE071TNXDEH/EU 1, 2, 220~240 V, 50 Hz 5.60 6.30 52.0 52.0 0.35 0.35 Cross flow Fan 1 15.7/13.8/12.0 261.7/230.0/200.0 BLDC 27x1 6.35 (1/4) 12.7 (1/2) 1, 2, 220~240 V, 50 Hz 6.80 7.00 60.0 60.0 0.40 0.40 Cross flow Fan 1 16.8/15.0/13.2 280.0/250.0/220.0 BLDC 27x1 9.52 (3/8) 15.88 (5/8) 1.5/2.5 1.5/2.5 0.75 0.75 R410A (Fluorinated greenhouse gas, GWP=2,088) EEV NOT INCLUDED EEV NOT INCLUDED 40/37/34/29 43/40/37/29 58 62 11.50 11.50 1,055 x 299 x 215 1,055 x 299 x 215 Auto Auto - - - Auto Auto - - - Capacities are based on (Equivalent refrigerant piping 7.5m, Level differences 0m) Cooling : Indoor temperature 27°C DB, 19°C WB / Outdoor temperature 35°C DB, 24°C WB Heating : Indoor temperature 20°C DB, 15°C WB / Outdoor temperature 7°C DB, 6°C WB 1 EEV Kit is necessary to control the refrigerant flow in the TDM Plus WindFreeTM Deluxe (EEV Excluded), please order EEV Kit separately. 2 Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 71 Specifications TDM Plus Slim Duct · Slim design with thickness of just 199 mm · Antibacterial filter included Specifications TDM Plus MSP Duct · External statuc pressure range from 0 to 1.4 mmAq · Built-in electronic expansion valve (EEV) for refrigerant flow control (2000 step) · Long-life washable permanent filter is included · Auto Restart function. · Built-in condensation drain pump (750 mmH2O) · SPi Ioniser device (optional) Power Supply Performance Power Fan Fan Motor Piping Connections Refrigerant Sound Dimensions Optional Accessories Type Model Name Capacity Power Input Current Input Type Quantity Air Flow Rate External Pressure Type Output x n Liquid Pipe Gas Pipe Type Sound Pressure Sound Power Net Weight Net Dimensions (W×H×D) Drain Pump Cooling / Heating Cooling / Heating Cooling / Heating H/M/L (UL) Max. (Min/ Std/Max) H/M/L Model Max. lifting Height/ Displacement , #, V, Hz kW W A EA m³/min mmAq Pa W , mm (inch) , mm (inch) dB(A) dB(A) kg mm mm / Litre/h Slim Duct AE022MNLDEH/EU 1, 2, 220~240 V, 50 Hz 2.2/2.5 55/55 0.30/0.30 Sirocco Fan 2 7.0 / 6.1 / 5.3 0/1/3 0/9.8/29.4 SSR non-feedback 28x1 6.35 (1/4) 12.7 (1/2) 26 / 24 / 21 49 19 700 x 199 x 600 MDP-E075SEE3D (Built-in) Slim Duct AE028MNLDEH/EU Slim Duct AE036MNLDEH/EU 1, 2, 220~240 V, 50 Hz 2.8/3.2 1, 2, 220~240 V, 50 Hz 3.6/4.0 60/60 65/65 0.32/0.32 0.33/0.33 Sirocco Fan Sirocco Fan 2 2 7.5 / 6.6 / 5.6 0/1/3 0/9.8/29.4 7.5 / 6.6 / 5.6 0/1/3 0/9.8/29.4 SSR non-feedback SSR non-feedback 28x1 28x1 6.35 (1/4) 6.35 (1/4) 12.7 (1/2) 12.7 (1/2) R410A (Fluorinated greenhouse gas, GWP=2,088) 28 / 26 / 23 32 / 30 / 27 49 51 19 19,5 700 x 199 x 600 700 x 199 x 600 MDP-E075SEE3D (Built-in) MDP-E075SEE3D (Built-in) Slim Duct AE056MNLDEH/EU 1, 2, 220~240 V, 50 Hz 5.6/6.3 95/95 0.53/0.53 Sirocco Fan 2 12.0 / 10.5 / 9.0 0/2/4 0/19.6/39.2 SSR non-feedback 28x1 6.35 (1/4) 12.7 (1/2) 36 / 34 / 31 55 24,5 900x199x600 MDP-E075SEE3D (Built-in) 750 / 24 750 / 24 750 / 24 750 / 24 Accessories Drain Pump (Built-in) MDP-E075SEE3D Remote Control AR-EH00 Touch Controller MWR-SH11N Wired Remote Control MWR-WE13N Wireless Receiver Kit MRK-A10N Touch Controller MCM-A300N DMS2.5 MIM-D01AN Wi-Fi Kit MIM-H04EN External Room Sensor MRW-TA Y-joint MXJ-YA1509M Power Supply Performance Power Fan Fan Motor Piping Connections Refrigerant Sound Dimensions Optional Accessories Type Model Name Capacity Power Input Current Input Type Quantity Air Flow Rate External Pressure Type Output x n Liquid Pipe Gas Pipe Type Sound Pressure Sound Power Net Weight Net Dimensions (W×H×D) Drain Pump Cooling / Heating Cooling / Heating Cooling / Heating H/M/L (UL) Max. (Min/ Std/Max) H/M/L Model , #, V, Hz kW W A EA m³/min mmAq Pa W , mm (inch) , mm (inch) dB(A) dB(A) kg mm - Max. lifting Height/ Displacement mm / Litre/h MSP Duct AE071MNMPEH/EU MSP Duct AE090MNMPEH/EU 1, 2, 220~240 V, 50 Hz 7.1/8.0 1, 2, 220~240 V, 50 Hz 9.0/10.0 120/120 145/145 1.0/1.0 1.2/1.2 Sirocco Fan Sirocco Fan 2 2 22 / 19 / 16 0 / 3 / 15 0 / 29.4 / 147.2 29 / 25 / 22 0 / 4 / 15 0 / 29.4 / 147.2 BLDC Feedback BLDC Feedback 153x1 153x1 9.52 (3/8") 9.52 (3/8") 15.88 (5/8") 15.88 (5/8") R410A (Fluorinated greenhouse gas, GWP=2,088) 37 / 33 / 29 38 / 35 / 32 57 58 25,5 33 850x250x700 1,200x250x700 MDP-G075SQ (Built-in) MDP-G075SP (External) MDP-G075SQ (Built-in) MDP-G075SP (External) 750 / 24 750 / 24 Accessories Drain Pump (Built-in) MDP-G075SQ External Drain Pump MDP-G075SP Remote Control Touch Controller AR-EH00 MWR-SH11N Wired Remote Control MWR-WE13N Touch Controller MCM-A300N DMS2.5 MIM-D01AN Wi-Fi Kit MIM-H04EN External Room Sensor MRW-TA Wireless Receiver Kit MRK-A10N Y-joint MXJ-YA1509M TDM Plus TDM Plus 72 73 Specifications TDM Plus Console · SPi Ioniser device (included) · Slim design with 199mm in depth · Built-in electronic expansion valve (EEV) for refrigerant flow control (2,000 step) · Long-life washable permanent filter · Auto Restart function · Two separate air outlets, upper (cooling) and bottom (heating) to avoid stratifications Dimensional Drawings TDM Plus Tank Integrated Hydro Unit AE200TNWTEH/EU, AE260TNWTEH/EU Power Supply Performance Power Fan Piping Connections Refrigerant Sound Dimensions Type Model Name Capacity Power Input Current Input Type Quantity Air Flow Rate Liquid Pipe Gas Pipe Type Sound Pressure Sound Power Net Weight Net Dimensions (W×H×D) Cooling / Heating Cooling / Heating Cooling / Heating H/M/L (UL) H/M/L , #, V, Hz kW W A EA m³/min , mm (inch) , mm (inch) dB(A) dB(A) kg mm Console AE022MNJDEH/EU 1, 2, 220~240 V, 50 Hz 2.2/2.5 16/16 0.13/0.13 Turbo Fan 1 6.3 / 5.4 / 4.9 6.35 (1/4) 12.7 (1/2) 34 / 32 / 30 52 15,5 720 x 620 x 199 Console AE028MNJDEH/ EU Console AE036MNJDEH/ EU 1, 2, 220~240 V, 50 Hz 2.8/3.2 1, 2, 220~240 V, 50 Hz 3.6/4.0 30/30 35/35 0.25/0.25 0.29/0.29 Turbo Fan Turbo Fan 1 1 7.0 / 6.0 / 5.0 8.50 / 7.50 / 6.50 6.35 (1/4) 6.35 (1/4) 12.7 (1/2) 12.7 (1/2) R410A (Fluorinated greenhouse gas, GWP=2,088) 38 / 36 / 34 39 / 37 / 34 58 59 16 16 720 x 620 x 199 720 x 620 x 199 Console AE056MNJDEH/ EU 1, 2, 220~240 V, 50 Hz 5.6/6.3 62/62 0.49/0.49 Turbo Fan 1 13.0 / 11.5 / 10.0 6.35 (1/4) 12.7 (1/2) 43 / 40 / 37 64 16 720 x 620 x 199 Accessories Touch Controller MWR-SH11N Remote Control (Included) MR-EH00 Touch Controller MCM-A300N DMS2.5 MIM-D01AN Wi-Fi Kit MIM-H04EN External Room Sensor MRW-TA Wired Remote Control MWR-WE13N Y-joint MXJ-YA1509M TDM Plus TDM Plus NO 1 2 3 4 5 6 7 8 9 Name Space heating Inlet Space heating Outlet DHW Inlet Secondary water return DHW Outlet Refrigerant liquid pipe Refrigerant Gas pipe T/Pv/v Drain Holes AE200TNWTEH/EU Description AE260TNWTEH/EU Ø28 Ø28 Ø22 N/A Ø22 Ø9.52 Ø15.88 Female PT 1/2" Ø28 Ø28 Ø22 Ø22 Ø22 Ø9.52 Ø15.88 Female PT 1/2" (Option) Connect with the provided drain plug 74 75 TDM Plus 793 13.7 52.7 332.0 779 116 178.8 241.8 Dimensional Drawings TDM Plus Outdoor AE044/066MXTPEH/EU 880.0 310 364.0 541 880 3 2 1 660.0 4 MOUNT BOLT SPEC : M6 x 4 NO 1 2 3 4 Name Refrigerant gas pipe for air Refrigerant gas pipe for water Refrigerant liquid pipe Drain holes 76 4.4 kW Description 15.88("5/8) 15.88("5/8) 9.52("3/8) Connect with the provided drain plug. 6.6 kW TDM Plus Outdoor AE090MXTP*H/EU 940 580.0 313 330 384.0 998 24 65 620 88 30 30 80 MOUNT BOLT SPEC : M6 x 4 4 55 95 55 95 6 5 4 55 80 22 67 Rear View 328.0 75 328 3 1 7 2 21 3 37 Detail for pipe position 66 104 NO 1 2 3 4 5 6 7 Name Refrigerant liquid pipe Refrigerant gas pipe for air Refrigerant gas pipe for water Knockout hole for pipe intake Power wiring conduits Communication wiring conduits Drain holes Description 9 kW 9.52("3/8) 9.52("3/8) 15.88("5/8) 15.88("5/8) Front / Side / Rear / Bottom Front / Side / Rear, 34("1-3/8) Front / Side / Rear, 22("7/8) Connect with the provided drain plug. 77 458 495 537 TDM Plus TDM Plus 1420 Dimensional Drawings TDM Plus Outdoor AE120/160MXTPH/EU 940 580 313 384.0 330 24 6 6 5 5 4 4 55 80 55 95 55 95 620.0 88 30 30 80 MOUNT BOLT SPEC : M6 x 4 4 22 67 75 328.0 7 3 1 2 483.7 520.5 562.8 NO 1 2 3 4 5 6 7 78 Name Refrigerant liquid pipe Refrigerant gas pipe for air Refrigerant gas pipe for water Knockout hole for pipe intake Power wiring conduits Communication wiring conduits Drain holes Detail for Service valve position 40.5 66.4 104.8 12 kW 15.88("5/8) 15.88("5/8) Front / Side / Rear / Bottom Front / Side / Rear, 34("1-3/8) Front / Side / Rear, 22("7/8) Connect with the provided drain plug. Description 9.52("3/8) 16 kW 15.88("5/8) 15.88("5/8) Front / Side / Rear / Bottom Front / Side / Rear, 34("1-3/8) Front / Side / Rear, 22("7/8) Connect with the provided drain plug. WindFreeTM Deluxe AE022/028/036TNXDEH/EU 889.0 215 466.6 889.0 422.4 65.0 245.0 64.0 397.0 64.0 65. 84.0 61.5 29.0 48.3 299.0 29.0 57.9 65.2 299 79 TDM Plus TDM Plus 299.0 29.0 Dimensional Drawings WindFreeTM Deluxe AE056/071TNXDEH/EU 1054.5 215 65.0 175.6 517.5 1054.5 537.0 631.5 64.0 64.0 61.5 29.0 62.4 65.0 84.0 80 58.1 65.0 299 650 600 477 Suspension position 71 100 10 OD25 26 115.5 145.5 199 151.6 18 100 TDM Plus TDM Plus Slim Duct AE022/028/036MNLDEH/EU 13 565.5 5 Suction 738.4 Suspension position 8 7 6 600 660 Air outlet duct flange 700 Discharge 18-3.2 Hole All around 700 800 500 NO 1 2 3 4 5 6 7 8 Name Liquid pipe connection Gas pipe connection Drain pipe connection without drain pump Drain pipe connection with drain pump Power supply/Communication connection Air discharge grille flange Return air side Hook Description 9.52("3/8) 6.35(1/4") 12.70(1/2") VP25(OD 32, ID 25) VP25(OD 32, ID 25) 9.52 or M10 12 4 182 3 246 333 81 TDM Plus Dimensional Drawings TDM Plus MSP Duct AE056MNLDEH/EU 10 100 199 900 465 293 18 939 899 118 5 101 600 or More (Service Space) 81 61 600 or More (Service Space) 477 8x100=800 6 860 27 115 145 152 100 18 4 53 83 171 181 245 21 3 332 NO 1 2 3 4 5 6 Name Gas pipe connection Liquid pipe connection Drain pipe connection Knockout hole for Drain pump Power supply & Communication wiring conduit Air outlet duct flange 82 5 Description 12.7(1/2) 6.35(1/4) VP-25(OD 32, ID 25) Option kit - TDM Plus MSP Duct AE071MNMPEH/EU 25 or More 25 or More 900 6 500 or More 7 Air Inlet [Service Space] Ceiling 186 164 27 700 or More [Service Space] 53 94 2x90=180 604 700 740 220 Air Inlet Air Outlet Air Outlet 850 952 250 220 818 7x100=700 59 5 21 125 213 323 34 57 NO 1 2 3 4 5 6 7 Name Liquid pipe connection Gas pipe connection Drain pipe connection Power supply & Communication wiring conduit Air suction flange Air discharge flange Hook Description 9.52(3/8) 15.88(5/8) VP-25(OD 32, ID 25) Use M8~M10 bolt(4ea) 83 TDM Plus Dimensional Drawings TDM Plus MSP Duct AE090MNMPEH/EU TDM Plus Console AE022/028/036/056MNJDEH/EU 185 25 or More 25 or More 163 27 700 or More [Service Space] 53 94 2x90=180 TDM Plus TDM Plus 220 1250 7 6 500 or More Air Inlet [Service Space] Ceiling 604 700 220 740 Air Inlet 250 Air Outlet 34 Air Outlet 1200 1302 1168 11x100=1100 5 21 125 213 323 34 590 199 88 70 620 48 49 65 5 720 86 124 SECTION C-C C 49 5 65 74 147 164 96 89 130 70 88 153 128 4 2 1A A 119 C 3 47 121 29 2 1 SECTION A-A NO 1 2 3 4 5 6 7 Name Liquid pipe connection Gas pipe connection Drain pipe connection Power supply & Communication wiring conduit Air suction flange Air discharge flange Hook 84 Description 9.52(3/8) 15.88(5/8) VP-25(OD 32, ID 25) Use M8~M10 bolt(4ea) NO 1 2 3 4 5 Name Liquid pipe connection Gas pipe connection Drain pipe connection Power supply & Communication wiring conduit Knockout hole for drain hose Description 6.35(1/4) 12.7(1/2) ID 18mm[11/16 inch] Hose - 85 TDM Plus TDM Plus Dimensional Drawings Wall-Mounted Hydro Unit AE090/160MNYD*H/EU NO 1 2 3 4 Name Gas Ref. Pipe Liquid Ref. Pipe Water Pipe (Inlet/Outlet) Drain Hose Connector Description 6.35 (1/4") (9kW), 9.52 (3/8) (16kW) 15.88 (5/8) BSPP male 11/4 86 Project: Atico en el Retiro (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Belén Imaz 87 88 Controls TDM Plus Controls 89 Line-up Category Product Individual Control Wireless Remote Controller System Wired Remote Controller Model AR-EH03E MR-EH00 MWR-WW10N Touch Controller MWR-WW00N MWR-WE13N MWR-SH11N Mono Control Kit MIM-E03CN Centralised Control System Touch Controller Wi-Fi Kit 2.0 MCM-A300N MIM-H04EN Integrated Control System DMS 2.5 MIM-D01AN Interface Module External Contact Interface Module & Gateway MIM-B14 Pulse Interface Module (PIM) MIM-B16N Modbus Interface module MIM-B19N Others S-Converter MIM-C02N External room sensor MRW-TA Receiver Kit MRK-A10N EHS ClimateHub R32 EHS Mono R32 EHS Split R32 Compatibility Table EHS with Third Party Tank EHS Mono R32 EHS Split R32 EHS Split R410A · · · ·* ·* · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · TDM Plus ClimateHub R410A · Wall-Mounted Hydro Unit ·* Compatibility Table TDM Plus R410A TDM Plus WindFreeTM Deluxe Slim Duct ·* optional · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · MSP Duct optional · · · · · · · · · · · Console ·* · · · · · · · · · · Controls Controls * No need to order separately, controller is already included. 90 91 Features Controls | Individual Control Wireless Remote Controller Standard with WindFreeTM AR-EH03E Wired Remote Controller Standard type for EHS MWR-WW10N Wired Remote Controller MWR-WE13N MWR-WW00N Wired Remote Controller Touch Simple type MWR-SH11N Mono Control Kit MIM-E03CN Wireless / Wired Remote Controllers · WindFreeTM On/Off · Filter replacement alarm reset · Simple On/Off timer · Indoor unit option code setting · Temperature setting range · Auto/Cool/Dry : 18 - 30 · Heat : 16 - 30 · Direct/Indirect function On/Off · Motion Detect Sensor necessary · Net dimensions (W x H x D): 48 x 138 x 24mm · Full color 4.3" LCD screen · Easy and Intuitive UI · 2-zone Control · LCD Backlight · Multiple Language support* · IR receiver is included · Daylight Savings Time · / Convertible · Error list display · Built-in room temperature sensor · SD slot · Net dimensions (W x H x D): 120 x 120 x 19mm * Available languages: English, German, Spanish, French, Italian and Polish. · Air conditioner/ERV operation setting (Horizontal air flow, WindFreeTM) · LCD Backlight · Air conditioner/ERV error monitoring · Air conditioner individual blade control · Filter cleaning alert/reset alert time · Air conditioner/ERV interlocking control · Energy saving control · Automatic operation stop function · Weekly operation schedule setting · Button restriction function · Built-in room temperature sensor · Real time clock (Daylight Savings Time) · Control max. 16 indoor units (Air conditioner + ERV) in group with single wired remote controller · Net dimensions (W x H x D): 120 x 124 x 19.5mm · Touch screen wired remote controller · LCD Backlight · IR receiver is included · Away function · Quiet mode, Sleep mode · Reset filter cleaning alert indicator · Air conditioner Individual/group control · Operation On/Off timer function · WindFreeTM/Long horizontal wind · Button locking function · Eliminate Operation Mode function : Auto/Cool/Dry/Fan/Heat mode · Built-in room temperature sensor · / Convertible · Relative temperature setting function : -3 ~ +3 setting · Control max. 16 indoor units in group with a single wired remote controller · Net dimensions (W x H x D): 94.2 x 122 x 19.5mm · EHS R32 Mono control Kit · Includes remote controller (MWR-WW10N) and flow sensor · Mounting box with the control printed board assembly · Leaving and return water sensors · Domestic Hot Water sensor · Net Dimensions (WxHxD) mm 290 x 110 x 370 mm Controls | Centralised Control Touch Controller MCM-A300N Wi-Fi Kit 2.0 MIM-H04EN Controls | Integrated Control DMS2.5 MIM-D01AN Centralised Control Systems · 7 inch touch LCD controller · Controls max. 128 indoor units · Controls max. 12 zones · Schedule control, Indoor unit usage restriction, View indoor unit error history · Net dimensions (W x H x D): 205 x 163 x 38mm · Enhanced Convenience · Voice Control available through a smartphone with Bixby · Connected home with affordable units in every home using SmartThings · Welcome cooling and heating based on Geo-fencing · Individual indoor unit control · Personalized Climate Environment · Preferred automation · Multi-device experience interoperable with smart appliances · Energy Usage Monitoring · Current and daily, weekly or monthly energy usage* of the outdoor unit · Provides ease of installation · Easy set-up possible for up to 16 indoor units at once · Net dimensions (W x H x D): 185 x 130 x 29mm Integrated Control Systems · Built-in web server for PC-independent management and remote access control · Multiple upper-layer control access (S-NET 3, Web-client) · Weekly/Daily schedule control · Power distribution function · Current time management even during power failure (for 24 hours) · Emergency stop function with simple contact interface · Individual/Group control of up to 256 indoor units, AHU and ERV · User editable control logic · Accessible level management. · Dynamic security management · Operation & error history management · Data storage in non-volatile memory & SD memory · Net dimensions (W x H x D): 240 x 255 x 65mm Controls Controls * Calculated by Samsung's own algorithm, it cannot be used as a legal basis. 92 93 Features Controls | Interface devices External Contact Interface Module MIM-B14 Modbus Interface Module MIM-B19N Pulse Interface Module (PIM) MIM-B16N Module, Application Kit, Gateway The Samsung Guestroom Management System saves users the energy and money wasted on cooling an unoccupied room. The air conditioner is activated when the Key-Tag is in place and turns off when the Key-Tag is removed. An external contact interface module provides direct indoor unit control via an external contact signal, as well as window-synchronised indoor unit control. The emergency control function features simple contact input. Plus the module generates indoor unit operation/error state output through relay contacts. · Direct indoor unit control by external contact signal · Window-synchronised indoor unit control · Emergency control with simple contact input · Indoor unit operation/error state output through relay contacts · Net dimensions (W x H x D): 50 x 80 x 35mm A BMS or 3rd controller can control a Samsung SAC by using the Modbus protocol. · BMS unit protocol: Modbus RS485 (2 wires, max. 1,000m) · Unit connection protocol: Samsung Control Layer Protocol (R1/R2) · Max. No. of connection units: 1 outdoor unit (4 outdoor units including sub units in the case of modular installation) and 48 indoor units · Modbus interface module address range : up to 247 · Net dimensions (W x H): 50 x 80mm The Watt-hour Meter Interface Module can be exclusively used for DMS 2.5 power distribution, displaying power consumption for each watt-hour meter. · Exclusive use for DMS 2.5 power distribution · Connection with up to 8 watt-hour meters · Pulse interface with watt-hour meters · Watt-hour meter - by 3rd party · Net dimensions (W x H x D): 240 x 255 x 65mm Controls | Others S-Converter MIM-C02N External Room Sensor MRW-TA Receiver Kit MRK-A10N Module, Application Kit, Gateway Communication converting module to connect a Samsung system air conditioner to a PC · Main reasons for use: - To connect with test run program [Test run program] - S-NET Pro: Conventional communication - S-NET Pro2: New communication · Net dimensions (W x H x D): 66 x 92 x 28mm · Indoor unit is operated by MRW-TA instead of its own sensor. · Wire length: 12 m (39 ft) · Concealed wireless signal receiver · Filter replacement sign · Fan operation display · Operation Timer setting display · Operation On/Off button · Operation On display LED (blue) · Defrost operation display LED (red) · Net dimensions (W x H x D): 80 x 130 x 28mm Controls Controls 94 95 96 Controls Accessories Accessories 97 Accessories Accessories Compatibility Accessories EEV Kit (1/2/3 room) Y-Joint Drain Pump Backup Heater Name Name 1 Indoor 2 Indoor 3 Indoor (15.0 kW and below) Internal External Internal 4 kW 6 kW Indoor unit Model code MEV-E24SA MEV-E32SA TDM Plus Slim Duct TDM Plus MSP Duct 2.2-5.6 kW 7.1-9.0 kW MXD-E24K132A MXD-E24K200A MXD-E32K200A MXD-E24K232A MXD-E24K300A MXD-E32K224A MXD-E32K300A MXJ-YA1509M · · MDP-E075SEE3D · MDP-G075SP · MDP-G075SQ · MHC-400FE MHC-600FE TDM Plus WindFreeTM Deluxe TDM Plus Console Wall-Mounted Hydro Unit EHS ClimateHub 2.2- 7.1 kW · · · · · · · · · 2.2-5.6 kW 9.0/16.0 kW 200/260 L · · · · (TDM Plus only) (TDM Plus only) · · 98 Project: Casa L (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Carlos Muntadas 99 100 Design and Support Accessories Design and Support 101 Samsung Climate Solutions Partner Portal As one of Samsung's registered Climate Solutions partners, you will have access to our Partner Portal and its many benefits. Whether you are looking for marketing materials or technical product documentation, requesting technical support or registering for training, the Samsung Climate Solutions Partner Portal offers you everything you need to consistently deliver the best results. Access technical resources The Technical Resources section provides you with all of the relevant information you need to understand the product's functionality and to prepare and design projects. A library full of technical information is at your fingertips, ranging from technical data books, BIM files and certificates to exploded views, drawings and different kinds of manuals. Request technical support You can easily request technical support through the Samsung Partner Portal by reporting your case using our built-in ticketing system. You can rest assured that our well-trained technical experts will work to solve your issue as soon as possible. Register for training If you are dedicated to becoming a Samsung climate solutions expert, you can access Samsung's educational portal for training sessions provided by experienced trainers. The portal allows you to search for online courses and materials, test your climate solutions knowledge, and more. The Samsung Business Academy is here to help you succeed.1 1 The registration process for and availability of training courses may vary per country. Please contact your direct Samsung contact person for more information. Obtain marketing resources How to access Potential buyers like to know that you are on the cutting edge of Samsung's latest innovations. To enable you to align with Samsung's marketing initiatives, the Partner Portal provides you with useful downloadable assets such as images and videos, designed to make your marketing activities easy and effective. 1 Register 2 Access 3 Manage account 4 Search and download To register for the Samsung Climate Solutions Partner Portal, open your web browser1 and go to partnerhub.samsung.com/ climate to complete the registration form. Your information will be verified and your account will be activated. You will receive your personal login details. 1 Google Chrome is the recommended web browser for using the Samsung Climate Solutions Partner Portal. Keep your account details up to date and invite your colleagues to join. Access a full library of resources, request technical support, or sign up for a Climate Solutions Academy training session. 102 103 Design and Support Design and Support 104 DVM Pro 2.0 Design and Support Design and Support 105 Design and Support Design and Support Samsung DVM Pro 2.0 NEW Samsung introduces new updated version of DVM Pro version 2.0. Product selection is extended and now the tool is also available for EHS and HVM lineup. Samsung DVM Pro 2.0 is an advanced design automation programme which helps you to select the most suitable equipment for easily and precisely designing your air conditioning system. It helps to ensure that the system's design falls within Samsung's engineering guidelines. With its reports, pipe and wire diagrams, additional refrigerant values and other information, Samsung DVM Pro 2.0 is a powerful tool for engineers, designers or installers. Sales Mode Sales Mode enables users to define their requirements and select air conditioning products quickly and easily. Product selection List of equipment, including indoor units, outdoor units, controls and accessories Piping schematics Basic or manual selection with system check and capacity simulation Reports Specifications, diagrams in DWG & BMP format, quotations Control systems Automatic control unit selection 106 Updated Toolbar NEW User-friendly tool bar helps to guide intuitively Wiring schematics Automatic diagrams including communication wiring for indoor/outdoor/ control units and electric power meters CAD Mode CAD Mode is an in-depth and precise design tool that enables users to design their air conditioning systems using AutoCAD software1. 1 Sourced separately. Pipe sizing & lengths Refrigerant & drain pipe sizing System check Installation regulation & refrigerant charging Automatic selection Refnet joint, header & distributor kit Performance simulation Capacity correction tool against specific design conditions Automatic report Piping installation Design wihout AutoCAD NEW Compatible with AutoCAD and AutoCAD LT for DWG. How to access 1 2 Register Select Go to dvmpro.mkt.samsung.com to access the Samsung DVM Pro 2.0 Portal1. If you do not have access yet, complete the registration process and you will be sent the access details. Click on DVM Pro 2.0 via the main menu and scroll to the end of the page to select the option DVM Pro 2.0 download. 1 Google Chrome is the recommended web browser for using the Samsung DVM Pro 2.0 Portal. 3 Download Download the DVM Pro 2.0 installation file, view the user manuals, and start designing your project. 107 Samsung Climate Solutions Academy Design and Support Design and Support 108 109 Samsung Climate Solutions Academy Samsung Climate Solutions Academy is committed to providing engineers with the technical skills required to install a Samsung product efficiently, and to help relay necessary information to users. All courses are designed to provide attendees with the opportunity to develop both theoretical and practical knowledge of Samsung's vast range of equipment and solutions. Samsung training centres in Europe Portugal - Lisbon United Kingdom - Mansfield United Kingdom - Chertsey Poland - Warsaw The Netherlands - Amsterdam France - Lyon Spain - Madrid Italy - Milan Greece - Athens Available training modules Essential courses: Basic commercial training Advanced courses: Technical training Advanced courses: Design training · The product line-up, accessories and available controls · The unique features of Samsung products · Installation considerations 110 · How to correctly install and configure a system · Commissioning: common issues during commissioning and how to resolve any challenges · Troubleshooting and fault-finding (by use of E-codes) · Control logic · Case studies · Understanding customers' needs and offering possible solutions · DVM Pro 2.0 - Samsung's advanced design tool · Case studies Note: the registration process for and availability of training courses may vary per country. Please contact your Samsung representative for more informa- How to register for training 1 2 Search To check for available training courses, go to Samsung Business Academy (SBA) via the Samsung Climate Solutions Partner Portal1: partnerhub.samsung.com/climate. Search the online event calendar and select the training course you would like to attend. Register After identifying the training course you would like to attend, follow the registration process. Once you have registered successfully you will receive a confirmation e-mail. 3 Get certified Following confirmation of your registration, we will invite you to one of our training centres. You will be trained by one of our specialised Master Trainers or Product Specialists, and receive a Certificate of Completion. 1 Google Chrome is the recommended web browser for using the Samsung Climate Solutions Partner Portal. 111 Design and Support Design and Support Design and Support Design and Support Hydraulic Schematics 112 Project: Casa L (Spain) Project Architecture: ÁBATON Interior Design: BATAVIA Photography: Carlos Muntadas 113 ClimateHub Split Application examples Application 1: Space heating + water heating Outdoor [ Supply Scope ] Outdoor unit Mechanical Room Indoor Hot Water Cold Water Tank Integrated Hydro Unit Room Controller 45°C Zone Control Supply Header Return Header Water pump #2 Radiators or Convectors Tw2_z2 Water pump #1 35°C Tw2_z1 Balancing Vessel Supply Header Return Header Under-Floor Heating Coils ClimateHub Split Application examples Application 2: Hybrid application (backup boiler and solar panel connected) Outdoor [ Supply Scope ] Outdoor unit Mechanical Room Solar thermal Panel Indoor Solar Panel Solar Pump Hot Water Cold Water Tank Integrated Hydro Unit Back up Boiler Operation Back-up Boiler Room Controller 45°C Zone Control Supply Header Return Header Water pump #2 Radiators or Convectors Tw2_z2 Water pump #1 35°C Tw2_z1 Balancing Vessel Supply Header Return Header Under-Floor Heating Coils Design and Support Design and Support 114 115 ClimateHub Mono Application examples Application 3: Space heating + water heating Outdoor [ Supply Scope ] Outdoor unit Mechanical Room Indoor Back up Boiler Operation Back-up Boiler 45°C Room Controller Zone Control Supply Header Return Header Tank Integrated Hydro Unit Water pump #2 Radiators or Convectors Tw2_z2 Water pump #1 35°C Tw2_z1 Balancing Vessel Supply Header Return Header Under-Floor Heating Coils ClimateHub TDM Plus Application examples Application 4: Space heating + water heating/ A2A cooling Outdoor [ Supply Scope ] Outdoor unit Y joint Mechanical Room Hot Water Cold Water Indoor Room Controller 45°C Zone Control Supply Header Return Header Tank Integrated Hydro Unit Water pump #2 Tw2_z2 Radiators or Convectors Space Heating Water pump #1 35°C Tw2_z1 Balancing Vessel EEV Kit Supply Header Return Header Under-Floor Heating Coils Space Cooling Design and Support Design and Support 116 117 Notes 118 Notes 119 Notes 120 Notes 121 Notes 122 Notes 123 Notes 124 Notes 125 Notes 126 Notes 127 Learn more about Samsung Climate Solutions at: www.samsung.com/climate Copyright © 2020 Samsung Electronics Air Conditioner Europe B.V. All rights reserved. Samsung is a registered trademark of Samsung Electronics Co., Ltd. Specifications and designs are subject to change without notice and may include preliminary information. Non-metric weights and measurements are approximate. All data was deemed correct at the time of creation. Samsung is not liable for errors or omissions. Some images may be digitally altered. All brand, product, service names and logos are trademarks and/or registered trademarks of their respective owners and are hereby recognised and acknowledged. Samsung Electronics Co., Ltd. participates in the Eurovent Certification Programme (ECP) for Air Conditioners (AC), Variable Refrigerant Flow (VRF) and Liquid Chilling Packages Heat Pump (LCP-HP). To check the ongoing validity of certification, please visit: www.eurovent-certification.com Samsung Electronics Air Conditioner Europe B.V. Evert van de Beekstraat 310, 1118 CX Schiphol P.O. Box 75810, 1118 ZZ Schiphol +31 (0)8 81 41 61 00 The NetherlandsAdobe InDesign 15.0 (Macintosh) Adobe PDF Library 15.0