SPECTRA Stack Library Utilizes LTO Tape Media User Guide
File info: application/pdf · 223 pages · 6.10MB
Spectra StackLibrary User Guide
Configure, use, & maintain the Spectra Stack library
Spectra, Stack
December 2021 User Guide—Spectra Stack Library 4 5. GRANT OF LICENSE AND RESTRICTIONS A. Spectra grants you a non‐exclusive, non‐transferable End‐User license right to install the Software Product solely for the purpose…
Extracted Text
Spectra Stack Library User Guide
SpectraLogic.com
Copyright Notices
Trademarks Part Number
Revision History
Copyright � 2018-2021 Spectra Logic Corporation. All rights reserved. This item and the information contained herein are the property of Spectra Logic Corporation.
Except as expressly stated herein, Spectra Logic Corporation makes its products and associated documentation on an "AS IS" BASIS, WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, BOTH OF WHICH ARE EXPRESSLY DISCLAIMED. In no event shall Spectra Logic be liable for any loss of profits, loss of business, loss of use or data, interruption of business, or for indirect, special, incidental or consequential damages of any kind, even if Spectra Logic has been advised of the possibility of such damages arising from any defect or error.
Information furnished in this manual is believed to be accurate and reliable. However, no responsibility is assumed by Spectra Logic for its use. Due to continuing research and development, Spectra Logic may revise this publication from time to time without notice, and reserves the right to change any product specification at any time without notice.
BlackPearl, BlueScale, CC, RioBroker, Spectra, SpectraGuard, Spectra Logic, StorCycle, TeraPack, TFinity, and TranScale are registered trademarks of Spectra Logic Corporation. Eon Protect and SeeVault are trademarks of Spectra Logic Corporation. MigrationPass is a service mark of Spectra Logic Corporation. All rights reserved worldwide. All other trademarks and registered trademarks are the property of their respective owners.
90970035 Revision F
Revision A B C D E F
Date March 2018 April 2018 December 2018 March 2019 June 2021 December 2021
Description Initial release. Corrections and expanded instructions. Updated for the BlueVision 1.8 release. Updated for the BlueVision 1.9 release. Updated for the BlueVision 2.0 release. Updated for the BlueVision 2.1 release.
Notes:
To make sure you have the most current version of this guide check the Spectra Logic Technical Support portal at support.spectralogic.com/documentation/user-guides/.
To make sure you have the release notes for the most current version of the BlueVision software, check the Spectra Logic Technical Support portal at support.spectralogic.com/ documentation/release-notes/.
You must sign into the portal before viewing Release Notes. The release notes contain updates to the User Guide since the last time it was revised.
December 2021
2
User Guide--Spectra Stack Library
End User License
Agreement
1. READ CAREFULLY
YOU SHOULD READ THE FOLLOWING TERMS AND CONDITIONS BEFORE ACCEPTING THIS END-USER LICENSE AGREEMENT (EULA). THIS EULA IS A LEGAL AGREEMENT BETWEEN YOUR ORGANIZATION, THE END USER, AND SPECTRA LOGIC CORPORATION (SPECTRA) FOR THE SPECTRA SOFTWARE PRODUCT WHICH INCLUDES COMPUTER SOFTWARE AND MAY INCLUDE ASSOCIATED MEDIA, PRINTED MEDIA, AND ONLINE OR ELECTRONIC DOCUMENTATION (COLLECTIVELY, SOFTWARE PRODUCT). BY INSTALLING, COPYING, OR OTHERWISE USING THE SOFTWARE PRODUCT, YOU AGREE TO BE BOUND BY THE TERMS OF THIS EULA. IF YOU DO NOT AGREE TO THE TERMS OF THIS EULA, YOU MAY NOT INSTALL, COPY, DOWNLOAD OR USE THE SOFTWARE PRODUCT. YOU AGREE THAT YOUR USE OF THE SOFTWARE ACKNOWLEDGES THAT YOU HAVE READ THIS AGREEMENT, UNDERSTAND IT, AND AGREE TO BE BOUND BY ITS TERMS AND CONDITIONS.
2. OWNERSHIP
It is understood and agreed that Spectra Logic Corporation, a Delaware corporation with offices at 6285 Lookout Road, Boulder, CO 80301 (Licensor) is the owner of all right, title and interest to the Software Product, regardless of the media or form of the original download, whether by the World Wide Web, disk or otherwise. You, as licensee (Licensee) through your downloading, installing, copying or use of this product do not acquire any ownership rights to the Software Product.
3. GENERAL
The Software Product is licensed, not sold, to you by Spectra for use only under the terms of this EULA. The Software Product is protected by copyright laws and international copyright treaties, as well as other intellectual property laws and treaties. The rights granted herein are limited to Spectras and its licensors intellectual property rights in the Software Product and do not include any other patents or intellectual property rights. The terms of this EULA will govern any software upgrades provided by Spectra that replace and/or supplement the original Software Product, unless such upgrade is accompanied by a separate license in which case the terms of that license will govern.
4. SOFTWARE PRODUCT
The Software Product, as used in this EULA, means, collectively and/or as applicable:
The Software Product package;
Any and all contents, components, attachments, software, media, and code with which this Agreement is provided and delivered;
Any and all images, photographs, art, art work, clip art, fonts or other artistic works (the Art Work);
Related explanatory written materials and instructions, and any other possible documentation related thereto (Documentation); and
Upgrades, modified versions, updates, additions and copies of the Software Product (the Upgrades), if any, licensed to by Spectra under this EULA.
December 2021
3
User Guide--Spectra Stack Library
5. GRANT OF LICENSE AND RESTRICTIONS
A. Spectra grants you a non-exclusive, non-transferable End-User license right to install the Software Product solely for the purpose for which it was created.
B. Unless provided otherwise in the Documentation or by prior express written consent of Spectra, you shall not display, modify, reproduce and distribute any Art Work, or portion(s) thereof, included with or relating to the Software Product, if any. Any such authorized display, modification, reproduction and distribution shall be in full accord with this EULA. Under no circumstances will your use, display, modification, reproduction and distribution of the Art Work give you any Intellectual Property or Proprietary Rights of the Art Work. All rights, title, and interest belong solely to Spectra.
C. Except for the initial loading of the Software Product, you shall not, without Spectras express written consent: Copy or reproduce the Software Product; or Modify, adapt, or create derivative works based on the Software Product or any accompanying materials.
6. DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS
A. Spectra will provide you with support services related to the Software Product (Support). Such Support will be provided in accordance with the Spectra Master Support Agreement, available for download and viewing on the Spectra Corporate Web site. Use of Support is governed by this EULA and Spectras Master Support Agreement.
B. Any supplemental software, code, content, or media provided to you in the course of Support shall be considered part of the Software Product and subject to the terms and conditions of this EULA.
C. Spectra retains all right, title, and interest in and to the Software Product, and any rights not granted to you herein are reserved by Spectra. You hereby expressly agree not to extract information, reverse engineer, disassemble, decompile, or translate the Software Product, or otherwise attempt to derive the source code of the Software, except to the extent allowed under any applicable law. In the event that such activities are permitted by applicable law, any information you, or your authorized agent, discover shall be promptly disclosed to Spectra and shall be deemed the confidential information of Spectra.
D. You shall not modify, sublicense, assign, or transfer the Software Product or any rights under this EULA, except as expressly provided in this EULA. Any attempt to sublicense, assign, or transfer any of the rights, duties, or obligations will be void.
E. You may permanently transfer all of your rights under this EULA, provided you retain no copies. The other party must agree to accept the terms and conditions of the EULA.
7. ALL RESERVED
All rights not expressly granted herein are reserved by Spectra.
December 2021
4
User Guide--Spectra Stack Library
8. TERM
A. This License is effective until terminated. Licensee may terminate it at any time by destroying the Software Product with all copies, full or partial, and removing all of its component parts.
B. Your rights under this EULA will terminate automatically without notice from Spectra if you fail to comply with any term(s) or condition(s) of this EULA. In such event, no notice shall be required by Spectra to effect such termination.
C. Upon termination of this EULA, you shall cease all use of the Software Product and destroy all copies, full or partial, together with all backup copies, modifications, printed or written materials, and merged portions in any form and remove all component parts of the Software Product.
9. INTELLECTUAL PROPERTY RIGHTS
A. Spectra shall retain all right, title, and interest in the Software Product and to any modifications or improvements made thereto, and any upgrades, updates or Documentation provided to End User. End User will not obtain any rights in the Software Product, its updates, upgrades, and Documentation, as a result of its responsibilities hereunder.
B. B. End User acknowledges Spectras exclusive rights in the Software Product and that the Software Product is unique and original to Spectra and that Spectra is owner thereof. Unless otherwise permitted by law, End User shall not, at any time during or after the effective Term of the Agreement, dispute or contest, directly or indirectly, Spectras exclusive right and title to the Software Product or the validity thereof.
10. U.S. GOVERNMENT END USERS
The Software Product and related documentation are Commercial Items, as that term is defined at 48 C.F.R. �2.101, consisting of Commercial Computer Software and Commercial Computer Software Documentation, as such terms are used in 48 C.F.R. �12.212 or 48 C.F.R. ��227.7202-1 through 227.7202-4, as applicable. The Commercial Computer Software and Commercial Computer Software Documentation are being licensed to U.S. Government end users (a) only as Commercial Items and (b) with only those rights as are granted to all other End Users pursuant to the terms and conditions herein. Unpublished rights reserved under the copyright laws of the United States.
11. EXPORT LAW ASSURANCES
You may not use or otherwise export or re-export the Software Product except as authorized by United States law and the laws of the jurisdiction in which the Software Product was obtained. In particular, but without limitation, the Software Product may not be exported or re-exported (a) into (or to a nation or resident of) any U.S. embargoed countries or (b) to anyone on the U.S. Treasury Departments list of Specially Designated Nationals or the U.S. Department of Commerce Denied Persons List or Entity List. By installing or using any component of the Software Product, you represent and warrant that you are not located in, under control of, or a national or resident of any such country or on any such list.
December 2021
5
User Guide--Spectra Stack Library
December 2021
12. DISCLAIMER OF WARRANTIES
YOU EXPRESSLY ACKNOWLEDGE AND AGREE THAT USE OF THE SOFTWARE PRODUCT IS AT YOUR SOLE RISK AND THAT THE ENTIRE RISK AS TO SATISFACTORY QUALITY, PERFORMANCE, ACCURACY AND EFFORT IS WITH YOU. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, AND EXCEPT AS MAY BE STATED IN THE SPECTRA MASTER SERVICE AGREEMENT, THE SOFTWARE PRODUCT IS PROVIDED AS IS, WITH ALL FAULTS AND WITHOUT WARRANTY OF ANY KIND, AND SPECTRA AND SPECTRAS AFFILIATES (COLLECTIVELY REFERRED TO AS SPECTRA FOR THE PURPOSES OF SECTIONS 12 AND 13) HEREBY DISCLAIM ALL WARRANTIES AND CONDITIONS WITH RESPECT TO THE SOFTWARE PRODUCT, EITHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES AND/OR CONDITIONS OF MERCHANTABILITY, OF SATISFACTORY QUALITY, OF FITNESS FOR A PARTICULAR PURPOSE, OF ACCURACY, OF QUIET ENJOYMENT, AND NON-INFRINGEMENT OF THIRD-PARTY RIGHTS. SPECTRA DOES NOT WARRANT AGAINST INTERFERENCE WITH YOUR ENJOYMENT OF THE SOFTWARE PRODUCT THAT THE FUNCTIONS CONTAINED IN THE SOFTWARE PRODUCT WILL MEET YOUR REQUIREMENTS, THAT THE OPERATION OF THE SOFTWARE PRODUCT WILL BE UNINTERRUPTED OR ERROR-FREE, OR THAT DEFECTS IN THE SOFTWARE PRODUCT WILL BE CORRECTED. NO ORAL OR WRITTEN INFORMATION OR ADVICE GIVEN BY SPECTRA OR A SPECTRA AUTHORIZED REPRESENTATIVE SHALL CREATE A WARRANTY. SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR LIMITATION ON APPLICABLE STATUTORY RIGHTS OF A CONSUMER, SO THE ABOVE EXCLUSION AND LIMITATIONS MAY NOT APPLY TO YOU.
13. LIMITATION OF LIABILITY
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL SPECTRA, ITS AFFILIATES OR LICENSEES, BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OF OR INABILITY TO USE THE SOFTWARE PRODUCT OR THE PROVISION OF OR FAILURE TO PROVIDE SUPPORT SERVICES, EVEN IF SPECTRA HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN ANY CASE, SPECTRAS ENTIRE LIABILITY UNDER ANY PROVISION OF THIS EULA SHALL BE LIMITED TO THE AMOUNT ACTUALLY PAID BY YOU FOR THE SOFTWARE PRODUCT; PROVIDED HOWEVER, IF YOU HAVE ENTERED INTO A MASTER SUPPORT AGREEMENT, SPECTRAS ENTIRE LIABILITY REGARDING SUPPORT SERVICES SHALL BE GOVERNED BY THE TERMS OF THAT AGREEMENT. BECAUSE SOME STATES AND JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY, THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
14. CONTROLLING LAW AND SEVERABILITY
This EULA will be governed by and construed in accordance with the laws of the State of Colorado, as applied to agreements entered into and to be performed entirely within Colorado between Colorado residents. This EULA shall not be governed by the United Nations Convention on Contracts for the International Sale of Goods, the application of which is expressly excluded. If for any reason a court of competent jurisdiction finds any provision, or portion thereof, to be unenforceable, the remainder of this EULA shall continue in full force and effect.
6
User Guide--Spectra Stack Library
Contacting Spectra Logic
To Obtain General Information
Spectra Logic Website: www.spectralogic.com
United States Headquarters
European Office
Spectra Logic Corporation 6285 Lookout Road Boulder, CO 80301 USA Phone: 1.800.833.1132 or 1.303.449.6400 International: 1.303.449.6400 Fax: 1.303.939.8844
Spectra Logic Technical Support
Spectra Logic Europe Ltd. 329 Doncastle Road Bracknell Berks, RG12 8PE United Kingdom
Phone: 44 (0) 870.112.2150
Fax: 44 (0) 870.112.2175
Technical Support Portal: support.spectralogic.com
United States and Canada Phone:
Toll free US and Canada: 1.800.227.4637 International: 1.303.449.0160
Europe, Middle East, Africa Phone: 44 (0) 870.112.2185
Deutsch Sprechende Kunden Phone: 49 (0) 6028.9796.507
Email: spectralogic@stortrec.de
Mexico, Central and South America, Asia, Australia, and New Zealand Phone: 1.303.449.0160
Spectra Logic Sales
Website: shop.spectralogic.com
United States and Canada Phone: 1.800.833.1132 or 1.303.449.6400 Fax: 1.303.939.8844 Email: sales@spectralogic.com
To Obtain Documentation
Europe Phone: 44 (0) 870.112.2150 Fax: 44 (0) 870.112.2175 Email: eurosales@spectralogic.com
Spectra Logic Website: support.spectralogic.com/documentation
December 2021
7
User Guide--Spectra Stack Library
Contents
About This Guide
14
Document Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Product Warranty Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
BLUEVISION USER INTERFACE SCREENS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 GENERAL WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 General Product Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
ACRONYMS AND ABBREVIATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 ADDITIONAL PUBLICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Chapter 1 � Product Overview
20
SUPPORTED LIBRARY CONFIGURATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 FRONT PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 REAR PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 TAPE DRIVE BACK PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 POWER SUPPLY BACK PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 ELEMENT NUMBERING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 ENCRYPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 TAPE CARTRIDGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Using and Maintaining Tape Cartridges . . . . . . . . . . . . . . . . . . . . . . . 31 Labeling Tape Cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Write Protecting Tape Cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Read and Write Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
INTEGRATION WITH A BLACKPEARL SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . 34
Chapter 2 � Using the BlueVision Interface
35
USING THE OPERATOR CONTROL PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 USING THE REMOTE MANAGEMENT INTERFACE . . . . . . . . . . . . . . . . . . . . . . . 36 LIBRARY USER TYPES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 LOGGING INTO THE LIBRARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
8
Contents
USING THE LIBRARY MAIN SCREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Top Banner Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Left Pane Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Right Pane Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Center Pane Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Chapter 3 � Configuring the Library
44
USING THE INITIAL CONFIGURATION WIZARD . . . . . . . . . . . . . . . . . . . . . . . . 45 SAVING, RESTORING, AND RESETTING THE LIBRARY CONFIGURATION . . . . . 46
Saving the Library Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Verify the Configuration Backup File . . . . . . . . . . . . . . . . . . . . . . . . . 48 Restoring the Library Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Resetting to the Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
CONFIGURING THE DATE AND TIME FORMAT . . . . . . . . . . . . . . . . . . . . . . . . 50
Setting the Time Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Setting the Date and Time Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Enabling SNTP (Simple Network Time Protocol) Synchronization 53
CONFIGURING MEDIA BARCODE COMPATIBILITY CHECKING . . . . . . . . . . . . 53 MODIFY BARCODE LABEL CHECKSUM TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . 54 ADD A LICENSE KEY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 CONFIGURING THE LIBRARY NETWORK SETTINGS . . . . . . . . . . . . . . . . . . . . . 56 RESET THE INTERNAL IP RANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 CONFIGURING SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 CONFIGURING EVENT NOTIFICATION PARAMETERS . . . . . . . . . . . . . . . . . . . . 61 CONFIGURING TAPE DRIVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 ENABLING OR DISABLING EE PORTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 CONFIGURING LIBRARY PARTITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Using the Basic Partition Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Using the Expert Partition Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
CONFIGURING ENCRYPTION KEY MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . 77
Configuring KMIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Using Encryption Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
CONFIGURE USER ACCOUNTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Configure User Account Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Configure Local User Accounts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 Configure LDAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
December 2021
9
User Guide--Spectra Stack Library
Contents
WEB MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Enabling SSL or SSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 Security Certificates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Session Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 OCP/RMI Session Locking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Restrict RMI Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Chapter 4 � Operating the Library
116
MOVING MEDIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Filtering Based on Barcode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Moving a Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
OPENING THE EE PORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 OPENING A MAGAZINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 CLEANING A TAPE DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 RESCANNING THE CARTRIDGE INVENTORY . . . . . . . . . . . . . . . . . . . . . . . . . . 121 FORCING A DRIVE TO EJECT A CARTRIDGE . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Chapter 5 � Viewing Library Status
123
VIEWING LIBRARY AND MODULE STATUS . . . . . . . . . . . . . . . . . . . . . . . . . . 124 USING INVENTORY LISTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Filtering by Barcode Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 Listing Just Drives or Cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 Viewing Elements by Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
USING THE CARTRIDGE INVENTORY GRAPHICAL VIEW . . . . . . . . . . . . . . . . 128 USING PARTITION MAP GRAPHICAL VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . 130 USING PARTITION MAP CONFIGURATION STATUS . . . . . . . . . . . . . . . . . . . . 132
Listing Just Drives or Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
VIEWING DRIVE STATUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 VIEWING NETWORK STATUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 VIEWING ENCRYPTION STATUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Chapter 6 � Configuring and Using Media Lifecycle
Management
139
BLUEVISION MEDIA LIFECYCLE MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . 140
Spectra Certified MLM-Enabled Media . . . . . . . . . . . . . . . . . . . . . . . 140 Media Tracking and Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 Additional MLM Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 MLM Usage Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
December 2021
10
User Guide--Spectra Stack Library
Contents
USING MLM REPORTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
Generate MLM Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Save an MLM Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 Override a Poor Cartridge Health Report . . . . . . . . . . . . . . . . . . . . . 149
MANAGING THE MLM DATABASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Backup the MLM Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Verify the Database Backup File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Restore the MLM Backup File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Delete MLM Records From the Database . . . . . . . . . . . . . . . . . . . . . 152
Chapter 7 � Maintaining the Library
153
LIBRARY TESTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
System Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 Slot to Slot Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 Element to Element Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 Position Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 Wellness Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 Robotics Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158 OCP Test and Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
LOGS AND TRACES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
Viewing Log Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 Downloading Log and Trace Files . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
SOFTWARE UPGRADES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
Managing System Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 Managing Drive Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
DOWNLOADING DRIVE LOGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 REBOOTING THE LIBRARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 REBOOTING DRIVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 CONTROLLING THE UID LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 MOVING THE ROBOTIC ASSEMBLY TO THE CONTROLLER MODULE . . . . . . 167 LTO-9 NEW MEDIA INITIALIZATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
Chapter 8 � Library Troubleshooting
171
FIBRE CHANNEL CONNECTION PROBLEMS . . . . . . . . . . . . . . . . . . . . . . . . . . 172 DETECTION PROBLEMS AFTER INSTALLING A SAS DRIVE . . . . . . . . . . . . . . 173
December 2021
11
User Guide--Spectra Stack Library
Contents
OPERATION PROBLEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Power Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 Failure/Attention Indications Displayed on the Operator
Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 Tape Movement Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 Media Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 Attention LED is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 Inventory Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 RMI Network Connection Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 Cleaning Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
PERFORMANCE PROBLEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
Average File Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 File Storage System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 Connection from the Backup/Archive Host Server to a
Disk Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 Backup/Archive Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 Backup/Archive Software and Method . . . . . . . . . . . . . . . . . . . . . . . 181 Connection from the Archive/Backup Host Server to the Library 181 Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
FINDING EVENT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 UNLOCKING THE MAGAZINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
Using the OCP or RMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 Using the Manual Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
UNLOADING A STUCK TAPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 IDENTIFYING A FAILED COMPONENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
Chapter 9 � Event Codes
185
ERROR EVENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 WARNING EVENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 CONFIGURATION CHANGE EVENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 INFORMATIONAL EVENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
Chapter 10 � Technical Support
203
ACCESSING THE TECHNICAL SUPPORT PORTAL . . . . . . . . . . . . . . . . . . . . . . 203
Create an Account . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 Log Into the Portal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
OPENING A SUPPORT TICKET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 RETURNS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
December 2021
12
User Guide--Spectra Stack Library
Appendix A � Specifications
Contents
211
PHYSICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Rack Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
ENVIRONMENTAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
LTO-9 Tape Drive Environmental Specifications . . . . . . . . . . . . . . 213
ELECTRICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214 REGULATORY SPECIFICATIONS (CSA TEST CONDITIONS) . . . . . . . . . . . . . . . 214 DEFAULT SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 BARCODE LABEL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 ELECTROSTATIC DISCHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
Preventing Electrostatic Damage . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 Grounding Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
Appendix B � Regulatory Information
222
RECYCLING AND DISPOSAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 CE MARK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 CCL MARK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 FCC (UNITED STATES) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 CANADIAN VERIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
December 2021
13
User Guide--Spectra Stack Library
About This Guide
Document Purpose
This document provides information to configure, maintain, and troubleshoot the Spectra� Stack Tape Library. The instructions are intended for the System Administrators and trained Users who need physical and functional knowledge of the Stack library. The main components are: Controller module: STACK BASE Expansion module: STACK EXP
Product Warranty Caution
Customers should only perform the service and repair actions on the tape library components using replacement instructions available on the Spectra Logic support portal. Any other actions must be performed by authorized service personnel. The warranty for the tape library shall not apply to failures of any unit when: The tape library is repaired or modified by anyone other than the
manufacturers personnel or approved agent. The tape library is physically abused or used in a manner that is
inconsistent with the operating instructions or product specification defined by the manufacturer. The tape library fails because of accident, misuse, abuse, neglect, mishandling, misapplication, alteration, faulty installation, modification, or service by anyone other than authorized service personnel. The tape library is repaired by anyone, including approved technicians, in a manner that is contrary to the maintenance or installation instructions supplied by the manufacturer. The manufacturers serial number tag is removed. The tape library is damaged because of improper packaging on return. The warranty becomes immediately void in the event of unauthorized repairs or modifications.
14
About This Guide
BLUEVISION USER INTERFACE SCREENS
BlueVision User Interface Screens
The BlueVision interface changes as new features are added or other modifications are made between software revisions. Therefore, the screens on your library may differ from those shown in this document.
GENERAL WARNINGS
Document Conventions
This document uses the following conventions to highlight important information:
WARNING
Read text marked by the "Warning" icon for information you must know to avoid personal injury.
Caution
Read text marked by the "Caution" icon for information you must know to avoid damaging the library or the tape drives, or losing data.
Important Read text marked by the "Important" icon for information that helps you complete
a procedure or avoid extra steps.
Note: Read text marked with "Note" for additional information or suggestions about the current topic.
AVERTISSEMENT Lisez le texte marqu� par l'ic�ne �Avertissement� pour les informations que vous devez conna�tre pour �viter les blessures.
Attention Lisez le texte marqu� par l'ic�ne �Attention� pour obtenir des informations que
vous devez conna�tre pour �viter d'endommager la biblioth�que ou les lecteurs de bande, ou de perdre des donn�es.
Important Lisez le texte marqu� par l'ic�ne �Important� pour obtenir des informations qui
vous aident � terminer une proc�dure ou � �viter des �tapes suppl�mentaires.
Remarque:Lisez le texte marqu� par �Remarque� pour obtenir des informations suppl�mentaires ou des suggestions sur le sujet actuel.
December 2021
15
User Guide--Spectra Stack Library
About This Guide
General Product Warnings
General Warnings
WARNING
High voltage
Risk of electric shock Do not remove covers (top, bottom or rear). No user-serviceable parts are
inside. Refer servicing to qualified service personnel. Plug the power cord into a grounded (earthed) electrical outlet that is easily
accessible at all times.
AVERTISSEMENT Haute tension Risque de choc electrique Ne retirez pas les capots (sup�rieur, inf�rieur ou arri�re). Aucune pi�ce r�parable par l'utilisateur ne se trouve � l'int�rieur. Confiez l'entretien � un personnel qualifi�. Branchez le cordon d'alimentation dans une prise �lectrique reli�e � la terre et facilement accessible � tout moment.
WARNING
Product Weight. See Physical Specifications on page 211.
Risk of personal injury
Before lifting a module: Observe local health and safety requirements and guidelines for manual
material handling. Remove all tapes to reduce the weight. Remove all tape drives to reduce the weight. Obtain adequate assistance to lift and stabilize the module during installation
or removal.
Risk of damage to library
When placing a module into or removing the module from a rack: Extend the rack's levelling jacks to the floor. Ensure that the full weight of the rack rests on the levelling jacks. Install stabilizing feet on the rack. Extend only one rack component at a time.
December 2021
16
User Guide--Spectra Stack Library
About This Guide
General Warnings
AVERTISSEMENT Poids du produit. Voir Sp�cifications physiques � la page 205. Risque de blessure corporelle
Avant de soulever un module: Respectez les exigences locales en mati�re de sant� et de s�curit� et les
directives pour la manutention manuelle des mat�riaux. Retirez toutes les bandes pour r�duire le poids. Retirez tous les lecteurs de bande pour r�duire le poids. Obtenez une assistance ad�quate pour soulever et stabiliser le module
pendant l'installation ou le retrait.
Risque d'endommagement de la biblioth�que
Lors du placement d'un module dans ou du retrait du module d'un rack: D�ployez les crics de mise � niveau du rack vers le sol. Assurez-vous que tout le poids du rack repose sur les v�rins de mise � niveau. Installez les pieds de stabilisation sur le rack. Prolongez un seul composant de rack � la fois.
WARNING
In earthquake- prone areas, the rack must have stabilizing equipment or be anchored to the floor to eliminate the risk of tipping, which could lead to personal injury.
AVERTISSEMENT Dans les zones sujettes aux tremblements de terre, le rack doit �tre �quip� d'un �quipement de stabilisation ou �tre ancr� au sol pour �liminer le risque de basculement, qui pourrait entra�ner des blessures.
WARNING
Only trained personnel should operate this equipment. Read all documentation and procedures before installation or operation. This product is intended for installation and operation in a computer rack with the front and rear doors closed and secured. Only personnel with technical and product safety training should be provided access to the library. Such personnel are referred to as users throughout this document. Do not insert any tools or any part of your body into openings of an operating library.
AVERTISSEMENT Seul un personnel form� doit utiliser cet �quipement. Lisez toute la documentation et les proc�dures avant l'installation ou l'utilisation. Ce produit est con�u pour �tre install� et utilis� dans un rack d'ordinateur avec les portes avant et arri�re ferm�es et s�curis�es. Seul le personnel ayant une formation technique et sur la s�curit� des produits doit avoir acc�s � la biblioth�que. Ce personnel est appel� utilisateur tout au long de ce document. N'ins�rez aucun outil ni aucune partie de votre corps dans les ouvertures d'une biblioth�que op�rationnelle.
MECHANICAL Danger Risk of hand pinching, can trap hands, fingers and cause serious
HAZARD
injury. Keep hands clear during operation.
DANGER M�CANIQUE
Danger Risque de se coincer la main et de se coincer les mains ainsi que les doigts le tout pouvant entrainer de graves blessures. Gardez les mains � l'�cart pendant le fonctionnement.
December 2021
17
User Guide--Spectra Stack Library
About This Guide
Acronyms and Abbreviations
ACRONYMS AND ABBREVIATIONS
Acronym or Abbreviation FC FH HBA HH LUN OCP RMI SAN SAS SNMP SSH SSL UID USB WORM WWNN WWPN
Meaning
Fibre Channel Full Height Host Bus Adapter Half Height Logical Unit Number Operator Control Panel (the library LCD screen) Remote Management Interface (the web interface) Storage Area Network Serial Attached SCSI Simple Network Management Protocol Secure Shell Secure Socket Layer Unit Identification Universal Serial Bus Write Once, Read Many World-Wide Node Name World-Wide Port Name
ADDITIONAL PUBLICATIONS
For additional information about the Spectra Stack library and its drives, refer to the publications listed in this section.
December 2021
18
User Guide--Spectra Stack Library
About This Guide December 2021
Additional Publications
Spectra Stack Library
This guide and the following documents related to the Spectra Stack library are available as PDF files on the Spectra Logic website at: support.spectralogic.com/documentation. The Spectra Stack Library Installation and Quick Configuration Guide
provides instructions for installing and configuring basic library functions. The Spectra Stack SCSI Developers Guide provides information about the SCSI Command set for the stack library.
The following documents are available after logging into your Support portal account at: support.spectralogic.com. The Spectra Stack Library Release Notes and Documentation Updates
provides the most up-to-date information about the Spectra Stack library, drives, and media. The following Field Replacement Unit Instructions: Spectra Stack Spool Robotics Replacement Instruction Spectra Stack Fan Replacement Instructions Spectra Stack Power Supply Replacement Instructions Spectra Stack Base-Exp Module Controller Replacement Instructions Spectra Stack Base Bezel W OCP Replacement Instructions Spectra Stack DC-DC Converter Replacement Instructions Spectra Stack Magazine Replacement Instructions Spectra Stack Rack Mount Instructions Spectra Stack Base-Exp Chassis Replacement Instructions Spectra Stack MigrationPass Instructions
LTO Ultrium Tape Drives
The following documents provide information that is applicable to all IBM LTO tape drives. IBM Tape Device Drivers Installation and User's Guide
Note: This guide also provides information about using the IBM Tape Diagnostic Tool (ITDT) to troubleshoot drive problems.
IBM TotalStorage LTO Ultrium Tape Drive: SCSI Reference
For drive-specific information, search for the product name (for example, LTO 6) on the documentation page on the IBM website. You can also search the IBM Support Portal at: http://www-947.ibm.com/support/entry/portal/Documentation.
KMIP
See the documentation specific to your server.
19
User Guide--Spectra Stack Library
CHAPTER 1
Product Overview
Built with maximum flexibility at its core, the Spectra Stack tape library meets your backup, archive, and perpetual storage requirements. Designed to be easily installed, expanded, and managed, the Spectra Stack is rated at 100% duty cycle - meaning it is built to perform in a 24/7 environment.
WARNING
Only trained personnel should operate this equipment. Read all documentation and procedures before installation or operation. This product is intended for
installation and operation in a computer rack with the front and rear doors closed
and secured. Only personnel with technical and product safety training should be
provided access to the library. Such personnel are referred to as users throughout
this document. Do not insert any tools or any part of your body into openings of an
operating library.
Topic Supported Library Configurations Front Panel Rear Panel Tape Drive Back Panels Power Supply Back Panel Element Numbering Encryption Tape Cartridges
Using and Maintaining Tape Cartridges Labeling Tape Cartridges Write Protecting Tape Cartridges Read and Write Compatibility Integration With a BlackPearl System
page 21 page 24 page 25 page 26 page 28 page 29 page 30 page 30 page 31 page 31 page 33 page 34 page 34
20
Chapter 1 -- Product Overview
SUPPORTED LIBRARY CONFIGURATIONS
Supported Library Configurations
All Spectra Stack library installations begin with the 6U controller module, with capacity for 80 tape cartridges and up to six half-height LTO tape drives, up to three full-height LTO tape drives, or a combination of half- height and full-height drives.
The Spectra Stack library is expandable, allowing a user to grow the tape storage capacity as data requirements increase. As data storage needs grow, the Spectra Stack library can also grow by adding one or more 6U expansion module(s). Each expansion module supports an additional 80 tape cartridges and an additional six half-height LTO tape drives or three full-height LTO tape drives.
Up to six expansion modules can be added to a controller module, bringing the total library capacity to 560 tape cartridges and 42 half-height drives, 21 full-height drives, or a combination of half- and full-height drives in a single 19-inch NEMA rack.
The controller module is depicted in this manual by the image on the left with the Operator Control Panel shown in yellow. Each expansion module is represented by the image on the right with a large clear viewing window in the center.
Figure 1 The controller module.
Figure 2 The expansion module.
Up to three expansion modules can be installed above and below the controller module. The table below shows the supported library configurations.
Module Quantity
1 Module Library Controller
Module
Supported Library Configurations
2 Module Library Controller
Module
1 Expansion Module
December 2021
21
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
Module Quantity
3 Module Library Controller
Module 2 Expansion
Modules
Supported Library Configurations
4 Module Library Controller
Module
3 Expansion Modules
Supported Library Configurations
5 Module Library Controller
Module
4 Expansion Modules
6 Module Library Controller
Module
5 Expansion Modules
December 2021
22
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
Module Quantity
7 Module Library Controller
Module 6 Expansion
Modules
Supported Library Configurations
Supported Library Configurations
December 2021
23
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
FRONT PANEL
Front Panel
This section describes the features accessible from the front panel of the library.
Figure 3 The front view of the Spectra Stack library.
Number 1 2 3 4 5
6
7
Component Left Magazine Access Door Power Button Operator Control Panel (OCP) USB Port EE Port/Right Magazine Access Door Error LED - Amber
Attention LED Amber
Description Provides access to the magazine on the left side of the module.
Controller Module Only Controller Module Only
Controller Module Only Provides access to the magazine and EE port on the right side of the module.
Controller Module Only - This LED illuminates when the library detects an unrecoverable tape drive or library error and is not capable of operation. Details of the error are displayed on the front panel screen. Controller Module Only - This LED illuminates when the library detects a condition which requires manual intervention, but the library can still perform most operations.
December 2021
24
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
Number Component
8
Clean LED - Amber
9
Ready LED - Green
10
Unit Identification
LED - Blue
Rear Panel
Description
Controller Module Only - This LED illuminates when a tape drive cleaning is needed.
Controller Module Only - This LED is steady green when the library is on, and blinks green when there is library robotics activity.
Controller Module Only - The unit identification LEDs on the front and back of the controller module are controlled by a user through the OCP and RMI Maintenance > UID LED Control screen. These lights are helpful for locating the library in a data center.
REAR PANEL
This section describes the features accessible from the rear panel of the library.
Figure 4 The rear view of the Spectra Stack library.
Number 1 2
Component Power Supplies Chassis Fan
Description 1 (standard) or 2 (redundant) Provides cooling for the library module.
December 2021
25
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
Tape Drive Back Panels
Number 3 4
5 6 7
8 9
Component
Controller Health Status LED - Green
Upper Expansion Module Connection Port
USB Port
Ethernet Ports
Lower Expansion Module Connection Port
Unit Identifier LED Blue
Drive Bays
10
Module Alignment
Mechanism
Description Indicates the module controller is operating normally.
If there is a module above this module, a cable connects from this port to the Lower Expansion Module Connection Port in the upper module. Controller Module Only Controller Module Only - Only one Ethernet port is usable. If there is a module below this module, a cable connects from this port to the Upper Expansion Module Connection Port in the lower module.
Half-height drive bays shown. Full-height drives use the space of two half-height drive bays. When there is an expansion module below this module, the alignment mechanism is extended to lock into the lower module.
TAPE DRIVE BACK PANELS
This section describes the elements of LTO tape drives used in the library.
IBM LTO-5/6/7/8/9 Half-Height SAS Drive
1 SAS Port A
2 SAS Port B
3 Tape Drive Power LED - Green
IBM LTO-5/6/7/8/9 Half-Height Single FC Port Drive
1 Fibre Channel Port A
December 2021
2 Tape Drive Power LED - Green
26
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
Tape Drive Back Panels
IBM LTO-5/6/7/8/9 Half-Height Dual FC Port Drive
1 Fibre Channel Port A
2 Fibre Channel Port B
3 Tape Drive Power LED - Green
IBM LTO-9 Full-Height Dual FC Port Drive
1 Fibre Channel Port A
2 Fibre Channel Port B
3 Tape Drive Power LED - Green
December 2021
27
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
POWER SUPPLY BACK PANEL
This section describes the power supply LEDs.
Power Supply Back Panel
Figure 5 The library power supply LEDs.
Number LED Color Meaning
1
White AC power is connected, but the library is powered off.
2
Amber Power supply fault condition. This can occur if the power
supply fan fails, or if the temperature or electrical power
output is outside of specification.
3
Green Module powered on.
December 2021
28
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
ELEMENT NUMBERING
Element Numbering
The library generally displays the logical numbering of modules, storage slots, and drives, from the bottom of the library to the top.
Figure 6 Example of library element numbering.
Number 1 2 3
Description Left magazine Right magazine with EE port disabled Right magazine with EE port enabled
December 2021
29
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
ENCRYPTION
Encryption
Encryption protects data written to tape from unauthorized access and use. The data is changed into a form that cannot be read until it is deciphered with the key used to encrypt the data.
LTO-5 and later generation tape drives include hardware that is capable of encrypting data while writing, and decrypting data when reading. Hardware-based data encryption can be used with or without compression while maintaining the full speed and capacity of the tape drive and media. LTO tape drives use the AES-256 encrypting algorithm to protect your data.
To use KMIP key management, you need the associated license key and a server with KMIP software.
The tape drives can read encrypted data from and write encrypted data to some earlier generation media. See Read and Write Compatibility on page 34.
TAPE CARTRIDGES
Use the Ultrium data cartridges designed for your model of drives. All drive generation use the ultrium universal cleaning cartridge
LTO Media Generation
Native Capacity (Compressed Capacity)
LTO-5 and LTO-5 WORM LTO-6 and LTO-6 WORM LTO-7 and LTO-7 WORM LTO-7 Type M LTO-8 and LTO-8 WORM LTO-9 and LTO-9 WORM
1.5 TB (3 TB a) 2.5 TB (6.25 TB b) 6 TB (15 TB b) 9 TB (22.5 TB b) 12 TB (30 TB b) 18 TB (45 TB b)
a. Assuming a 2:1 compression ratio. The compressed capacity depends on the type of data. b. Assuming a 2.5:1 compression ratio. The compressed capacity depends on the type of data.
Note: LTO-5 and later tape drives support both rewriteable and WORM data cartridges. Write-Once, Read-Many (WORM) data cartridges provide an enhanced level of data security against accidental or malicious alteration of data on the tape cartridge. The WORM data cartridge can be appended to maximize the full capacity of the tape cartridge, but you cannot erase or overwrite data on the cartridge.
December 2021
30
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
Using and Maintaining Tape Cartridges
Tape Cartridges
Caution
Do not degauss LTO data cartridges! These data cartridges are pre-recorded with a magnetic servo signal. This signal is required to use the cartridge with LTO tape
drives. Keep magnetically charged objects away from the cartridge.
To ensure the longest possible life for your data cartridges, follow these guidelines:
Use only the data cartridges designated for your drives. See Read and Write Compatibility on page 34.
Clean the tape drive when the Clean drive LED is illuminated.
Use only Ultrium Universal cleaning cartridges.
Be careful not to drop a cartridge.. Excessive shock can damage the internal contents of the cartridge or the cartridge case itself, making the cartridge unusable.
Do not expose data cartridges to direct sunlight or sources of heat, including portable heaters and heating ducts.
The operating temperature range for data cartridges is 50� F to 95� F (10� C to 35� C). The storage temperature range is -40� F to 140� F (-40� C to 60� C) in a dust-free environment in which relative humidity is always between 20% and 80% (non-condensing).
If a data cartridge is exposed to temperatures outside the specified range, acclimate the cartridge at room temperature for the same length of time it was exposed to extreme temperatures or 24 hours, whichever is less.
Do not place data cartridges near sources of electromagnetic energy or strong magnetic fields such as computer monitors, electric motors, speakers, or X-ray equipment. Exposure to electromagnetic energy or magnetic fields can destroy data and the embedded servo code written on the media by the cartridge manufacturer, which can render the cartridge unusable.
Place identification labels only in the designated area on the cartridge.
Labeling Tape Cartridges
The library contains a barcode reader that reads the tape labels and stores the barcode data as part of the library inventory. The library then provides the inventory information to the host application, OCP, and RMI. Having a barcode label on each tape cartridge enables the barcode reader to identify the cartridge quickly, thereby speeding up inventory time.
Important The tape library does not support unlabeled media. Make sure every cartridge has a
barcode label in place.
December 2021
31
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
Tape Cartridges
Important All barcode labels must be checksummed or no-checksummed. You cannot mix the
two types in the library.
A proper barcode label includes the media identifier in the last two characters of the barcode. The library will not load an incompatible cartridge, based on the barcode media identifier, into a tape drive. For example, the library will not load a cartridge labeled as LTO-3 into an LTO- 6 tape drive. This saves the time needed to load the cartridge and have the tape drive reject it.
Though not recommended, disabling barcode checking in the Configuration > Ignore Barcode Media ID screen allows all media moves regardless of the barcode media identifier.
Your host software may need to keep track of the following information via the associated barcode:
Date of format or initialization Tapes media pool Data residing on the tape Age of the backup Errors encountered while using the tape (to determine if the tape is
faulty)
Important Misusing and misunderstanding barcode technology can result in backup and
restore failures. Use only high quality labels. Self-printed labels are not recommended as they are often a source of barcode reading issues.
Important The barcode label should only be applied as shown, with the alphanumeric portion
facing the hub side of the tape cartridge. Never apply multiple labels onto a cartridge because extra labels can cause the cartridge to jam in a tape drive.
LTO tape cartridges have a recessed area located on the face of the cartridge next to the write-protect switch. Use this area for attaching the adhesive-backed barcode label. Only apply labels as shown:
December 2021
Figure 7 Tape cartridge barcode location. Note: For detailed information on tape barcode specifications, see Barcode Label Specifications on page 217.
32
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
Write Protecting Tape Cartridges
Tape Cartridges
All rewriteable data cartridges have a write-protect switch to prevent accidental erasure or overwriting of data. Before loading a cartridge into the library, make sure the write-protect switch on the front of the cartridge is in the desired position.
Slide the switch to the left to allow the drives to write data to the cartridge.
Slide the switch to the right to write-protect the cartridge. An indicator, such as a red mark or small padlock, is visible showing that the cartridge is write-protected.
Figure 8 Tape cartridge features.
Callout 1 2 3 4 5
Feature Insertion Arrow Barcode Label Write-Protect Switch Write-Protected Write-Enabled
December 2021
33
User Guide--Spectra Stack Library
Chapter 1 -- Product Overview
Read and Write Compatibility
Integration With a BlackPearl System
Drive Gen LTO-5 LTO-6 LTO-7 LTO-8 LTO-9
LTO-5 Media
LTO-6 Media
LTO-7 Media
M8 Media LTO-8 Media
LTO-9 Media
Read/ write
Not
Not
Not
Not
Not
supported supported supported supported supported
Read/ write
Read/ write
Not
Not
Not
Not
supported supported supported supported
Read only Read/ write
Read/ write
Not
Not
Not
supported supported supported
Not
Not
Read/
supported supported write
Read/ write
Read/ write
Not supported
Not
Not
Not
Not
Read/
supported supported supported supported write
Read/ write
INTEGRATION WITH A BLACKPEARL SYSTEM
Spectra Stack libraries can be used with BlackPearl systems running BlackPearl 4.1.2 or later. For information on using a Stack library in a BlackPearl system, see the Spectra BlackPearl User Guide.
December 2021
34
User Guide--Spectra Stack Library
CHAPTER 2
Using the BlueVision Interface
This chapter provides information on using the BlueVision interface.
Topic Using the Operator Control Panel Using the Remote Management Interface Library User Types Logging into the Library Using the Library Main Screen
Top Banner Elements Left Pane Elements Center Pane Elements
page 36 page 36 page 37 page 38 page 39 page 40 page 41 page 43
The library provides two main interfaces:
Operator Control Panel (OCP) - With the OCP, you can monitor, configure, and control the library from the LCD screen on the controller module.
Remote Management Interface (RMI) - With the RMI, you can monitor, configure, and control the library from a web browser. The RMI hosts a dedicated, protected website that displays a graphical representation of the library.
The OCP and RMI are similar in design and functionality.
Before using the RMI, you must configure the library network settings and set the administrator password with the OCP. This is typically done using the Initial Configuration Wizard, see Using the Initial Configuration Wizard on page 45.
When possible, it is recommended that the RMI be used as the primary library interface because the web interface provides access to additional features, such as configuring SNMP, IPv6, encryption, and partitions, includes online help, and is easier to use.
35
Chapter 2 -- Using the BlueVision Interface
USING THE OPERATOR CONTROL PANEL
Using the Operator Control Panel
Indicator Module ID
Ready Clean Attention
Error
The OCP has a power button, an LCD touch screen, five indicator LEDs, and a USB port (see Figure 3 on page 24). With the OCP you can monitor, configure, and operate most library functions from the library LCD screen on the controller module. To navigate the OCP, click on the LCD touch screen.
Front Panel LED Indicators
Meaning
Blue when activated. The unit identification (UID) LEDs are controlled by the user through the OCP and RMI Maintenance > UID LED Control screen. The UIDs on the OCP and back panel UID are activated and deactivated together. The UIDs are helpful for locating the library in a data center.
Steady green when the library is on, and blinking green when there is library robotic assembly activity.
Amber when a tape drive requires cleaning.
Amber blinking if the library detects a condition for which user attention is necessary, but which does not prevent the library from performing most operations.
Amber if an unrecoverable tape drive or library error occurs. A corresponding error message displays on the LCD screen. User intervention is required; the library is not capable of performing some operations.
USING THE REMOTE MANAGEMENT INTERFACE
With the RMI, you can monitor, configure, and operate most library functions from a web browser. To start the RMI, open the latest version of a supported HTML browser and enter the IP address of the library in the browsers address bar. Supported browsers include Internet Explorer, Firefox, Chrome, and Safari.
Important Check the online help in the RMI for additional information. The help pages are
updated with firmware updates and often contain up-to-date technical details that might not be contained in this document. To access RMI help, click the ? icon on the right side of the RMI top banner.
December 2021
36
User Guide--Spectra Stack Library
Chapter 2 -- Using the BlueVision Interface
LIBRARY USER TYPES
Library User Types
The library offers four types of user, each with different levels of access to library functions.
Administrator � The administrator user has access to all functionality except for the log configuration, service features, and encryption features.
Important By default, the administrator password is not set. You must set the administrator
password from the OCP (see Configuring Encryption Key Management on page 77) before you can access the administrator functions on the RMI.
User � The user account provides access to status information, but not configuration, maintenance, or operation functions.
Important By default, the user password is not set.
Service � This user is for use by service personnel only. The service password is set at the factory. To access the service features of the library, both the administrator and service passwords must be entered.
Security - The security user has access to all administrator functionality and can also configure security features and change the security user password.
Important By default, the security password is set to security. You must change the
security password from the OCP before the account can be used from the RMI (see Configuring Encryption Key Management on page 77).
December 2021
37
User Guide--Spectra Stack Library
Chapter 2 -- Using the BlueVision Interface
LOGGING INTO THE LIBRARY
Logging into the Library
Use the instructions in this section to log into the library. The process is similar when using either the OPC or RMI.
1. Access the user interface:
Using the OCP - touch the screen to clear the screen saver and display the login screen.
Using the RMI - open a web browser and enter the IP address of the library in the browser address bar.
The Login screen displays.
Figure 9 The Login screen.
2. Using the drop-down menu, select the desired User. 3. If necessary, enter the Password for the user. 4. Click Login.
December 2021
38
User Guide--Spectra Stack Library
Chapter 2 -- Using the BlueVision Interface
USING THE LIBRARY MAIN SCREEN
Using the Library Main Screen
The library main screen is organized into the following regions:
Top Banner - Contains the home button and displays the overall library status and information about the library and the current user. See Top Banner Elements on page 40.
Left Pane - Displays the library identity and all module statuses. See Left Pane Elements on page 41.
Right Pane - (RMI only) Displays a log of recent events or a navigation menu after clicking one of the center buttons. See Right Pane Elements on page 42.
Center Pane - Provides access to operate and configure the library, and to view additional status information. See Center Pane Elements on page 43.
Figure 10 Spectra Stack main screen.
December 2021
39
User Guide--Spectra Stack Library
Chapter 2 -- Using the BlueVision Interface
Top Banner Elements
Using the Library Main Screen
Figure 11 The BlueVision top banner.
Icon Home Icon Library Health
Meaning
Returns to the library main screen. An icon indicating the overall health status of the library.
OK - The green check mark icon indicates the library is fully operational.
Warning - The yellow exclamation point icon indicates that user attention is necessary, but the library can continue most operations.
Error - The red X icon indicates that the library experienced an error that prevents it from continuing normal operations, and user intervention is required.
Status
The status of the library robotics: Idle - The library robotics is ready to perform an action. Moving - The library robotics is moving a cartridge. Scanning - The library robotics is performing an inventory of cartridges. Offline - The library robotic assembly has been taken offline by the library.
Library Time & Date Helpful when analyzing event logs and support tickets, and might be needed when contacting support.
User
The user account for this session.
Logout
Logs out of this session.
?
Accesses online help. When using RMI, you can search the online help for a
specific term by pressing CTRL+F on the keyboard.
December 2021
40
User Guide--Spectra Stack Library
Chapter 2 -- Using the BlueVision Interface
Left Pane Elements
Using the Library Main Screen
The left pane displays general library information and module status information.
Parameter Serial # Hostname Network Configuration Firmware
Figure 12 The BlueVision left pane.
Library Information
Meaning The controller module serial number. The library hostname. The internet protocol version (IPv4, IPv6, or both) and IP address.
The current library firmware version.
December 2021
41
User Guide--Spectra Stack Library
Chapter 2 -- Using the BlueVision Interface
Using the Library Main Screen
Module Status Overview
The module status overview provides a summary of each modules configuration and health. Selecting a module displays additional information.
Parameter
Meaning
Module Health Icon
OK - The green check mark icon indicates the library is fully operational.
Module Number Drive Status
Magazine Slot Usage Drive Operation Status
Warning - The yellow exclamation point icon indicates that user attention is necessary, but the library can continue most operations.
Error - The red X icon indicates that the library experienced an error that prevents it from continuing normal operations, and user intervention is required.
Modules are numbered based on their location in the physical library. The bottom module is Module 1. The controller module is annotated with "(Base)".
The number of drives installed in the module and the health of each drive. Click the drive to display drive configuration and status information in the center pane. A black square indicates that the drive is fully operational and that no user
intervention is required. A yellow square indicates that user attention is necessary, but that the drive
can still perform most operations. A red square indicates that user intervention is required or the drive is not
capable of performing some operations.
The number of cartridge slots used and the number available formatted as xx/yy where xx= slots used and yy=slots available.
The current drive activity for each drive in the module. The drive operation status is only displayed for the selected module. Write - The drive is performing a write operation. Read - The drive is performing a read operation. Idle - A tape cartridge is in the drive but the drive is not performing an
operation. Empty - The drive is empty. Encryp - The drive is configured to read and write encrypted data.
Right Pane Elements
The right pane displays a log of recent events or a navigation menu after clicking one of the center buttons described in Center Pane Elements on page 43.
December 2021
42
User Guide--Spectra Stack Library
Chapter 2 -- Using the BlueVision Interface
Center Pane Elements
Using the Library Main Screen
Figure 13 The BlueVision home page center pane.
Selection
Open EE Port (Administrator or Security user only)
Open Magazine (Administrator or Security user only)
Configuration (Administrator or Security user only)
Maintenance (Administrator or Security user only)
Operation (Administrator or Security user only)
Status
Meaning
Click to access the Operations > Open EE Port screen to see the status of EE port(s) and select an EE port to open. EE ports must be enabled before the slots can be used as EE ports. See Enabling or Disabling EE Ports on page 64.
Click to access the Operation > Open Magazine screen to select a magazine to open. Only one magazine in the library can be open at a time. See Opening a Magazine on page 119.
Click to configure the library system, network, drives, EE ports, partitions, encryption, user accounts, and web management settings. See Configuring the Library on page 44.
Click to access maintenance functions including running system tests, collecting logs and traces, upgrading software, downloading drive logs, rebooting the system, rebooting drives, controlling the UID LEDs, and moving the robotic assembly to the control module. See Maintaining the Library on page 153.
Click to access operation functions including moving media, cleaning drives, rescanning inventory, and forcing drive media ejection. See Operating the Library on page 116.
Click to access cartridge inventory, status information, and Media Lifecycle Management (MLM). See Viewing Library Status on page 123 and Configuring and Using Media Lifecycle Management on page 139.
December 2021
43
User Guide--Spectra Stack Library
CHAPTER 3
Configuring the Library
This chapter contains instructions for configuring the Spectra Stack library. Before using this chapter, install the library using the Spectra Stack Library Quick Start Guide.
Topic Using the Initial Configuration Wizard Saving, Restoring, and Resetting the Library Configuration
Saving the Library Configuration Restoring the Library Configuration Resetting to the Default Settings Configuring the Date and Time Format Setting the Time Zone Setting the Date and Time Format Setting the Date and Time Enabling SNTP (Simple Network Time Protocol) Synchronization Configuring Media Barcode Compatibility Checking Modify Barcode Label Checksum Type Add a License Key Configuring the Library Network Settings Reset the Internal IP Range Configuring SNMP Configuring Event Notification Parameters Configuring Tape Drives Enabling or Disabling EE Ports Configuring Library Partitions Using the Basic Partition Wizard Using the Expert Partition Wizard Configuring Encryption Key Management Configuring KMIP Using Encryption Standard
page 45 page 46
page 47 page 48 page 49 page 50 page 51 page 51 page 52 page 53
page 53 page 54 page 55 page 56 page 57 page 59 page 61 page 63 page 64 page 65 page 66 page 70 page 77 page 78 page 83
44
Chapter 3 -- Configuring the Library
Topic Configure User Accounts
Configure User Account Settings Configure Local User Accounts Configure LDAP Web Management Enabling SSL or SSH Security Certificates Session Timeout OCP/RMI Session Locking Restrict RMI Access
Using the Initial Configuration Wizard
page 101 page 101 page 103 page 106 page 110 page 110 page 111 page 114 page 114 page 115
USING THE INITIAL CONFIGURATION WIZARD
The Initial Configuration Wizard guides you through setting the administrator password, configuring the time zone, date and time, and library network settings, and then starting an initial system test. You can skip items and stop the wizard at any time. Once you have configured the network settings and set the administrator password from the OCP, you can initiate the wizard from the RMI or use the OCP to complete the remaining configurations. For a detailed description of the Initial Configuration Wizard, see the Spectra Stack Library Quick Start Guide.
December 2021
45
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Saving, Restoring, and Resetting the Library Configuration
SAVING, RESTORING, AND RESETTING THE LIBRARY CONFIGURATION
You can save the library configuration settings to a file, restore the settings, or reset the library configuration to the default settings from the Configuration > System > Save/Restore Configuration screen. The saved configuration database makes it easier to recover the library configuration if you need to replace the controller module or the controller in the controller module.
Figure 14 The Save/Restore System Configuration screen.
Important The backup configuration can only be used to restore the library that generated the
backup. The configuration is tied to the Hardware ID of the library and cannot be transferred to another library.
Note: The library configuration backup does not contain the MLM database. To backup the MLM database, see Backup the MLM Database on page 151.
The library configuration backup can be generated using the library operator control panel to save the file to a USB device, or using the RMI to download the backup file.
December 2021
46
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Saving, Restoring, and Resetting the Library Configuration
The following settings are not saved in the backup configuration file:
The administrator password Date and time Library hostname KMIP certificates License keys Library MAC address Library, controller, and chassis serial numbers Robot calibration data Operator control panel calibration data Library hardware configuration Note: If you have previously saved a configuration backup file and
want to use the file to restore the library configuration, see Restoring the Library Configuration on page 48.
Saving the Library Configuration
1. Login to the library as a user with administrator privileges.
2. Navigate to the Configuration > System > Save/Restore Configuration screen as shown Figure 14.
3. If necessary, click Save Configuration File to expand the section.
4. If you are using the OCP, insert a USB device into one of the USB ports on the controller module.
5. Click Save.
Note: It takes approximately three minutes for the library to display Download and Cancel buttons.
The destination location depends on how you are accessing the library: RMI -- (RMI only) Downloads the configuration file through the
browser to the system running the RMI. USB Device -- (OCP only) Downloads the configuration file to a
USB device inserted into the USB port on the front or the back of the library.
6. Click Download.
December 2021
47
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Saving, Restoring, and Resetting the Library Configuration
Verify the Configuration Backup File
After creating a backup of your library configuration, use one of the methods described in the following sections to verify that the backup was successful as soon as possible after you create it.
When Saved to a USB Device
1. Plug the USB device into a USB port on a host computer.
2. Examine the list of files on the USB device and locate the ZIP file containing the system configuration backup. The file is named: syslog- LibraryName-PackageLevel-Timestamp.ZIP.
3. Open the ZIP file and confirm the file "details.bin" is present and greater than 0 bytes.
Note: The ZIP file also contains text files of different library messages. If no messages of a given type are present in the library, the log for that message type is 0 bytes.
When Saved to a Host Computer
1. Locate the ZIP file containing the system configuration backup. The file is named: syslog-LibraryName-PackageLevel-Timestamp.ZIP.
2. Open the ZIP file and confirm the file "details.bin" is present and greater than 0 bytes.
Note: The ZIP file also contains text files of different library messages. If no messages of a given type are present in the library, the log for that message type is 0 bytes.
Restoring the Library Configuration
Note: Restoring the configuration from a saved configuration file restores passwords for the users with security and user roles, but does not restore an administrator user password.
1. Login to the library as a user with administrator privileges. 2. Navigate to the Configuration > System > Save/Restore Configuration
screen. 3. If necessary, click Restore Configuration File to expand the section.
December 2021
48
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Saving, Restoring, and Resetting the Library Configuration
4. If you are using the OCP to restore the configuration file from a USB device, copy the configuration file you want to restore onto the USB device and remove any other configuration files from the USB device.
Note: If multiple library configuration backups are present on the USB device, the library uses the most recent backup to restore the configuration.
Insert the USB device containing the configuration file into one of the USB ports on the controller module.
5. Select the source location:
RMI -- (RMI only) Restores the configuration file from the computer running the RMI. Select Choose File and use your web browser to select the configuration file you want to restore.
USB Device -- (OCP only) Restores the configuration file from a USB device inserted into the USB port on the front or the back of the library.
6. Click Upload File & Restore. The library reboots to restore the configuration.
Resetting to the Default Settings
To reset the library configuration to the default settings, you must be logged in as the Administrator or Security user.
1. Log in as the security user.
2. Navigate to the Configuration > System > Save/Restore Configuration screen shown above.
3. If necessary, click Reset Default Settings to expand the section.
4. Click Reset Default Settings.
For the detailed listing of the default settings, see Default Settings on page 215.
December 2021
49
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring the Date and Time Format
CONFIGURING THE DATE AND TIME FORMAT
You can configure the date and time format, the current date and time, and an SNTP server from the Configuration > System > Date and Time Format screen.
Note: The library does not adjust its time for daylight savings; the time must be adjusted manually.
Figure 15 The Date and Time Format screen.
December 2021
50
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Setting the Time Zone
Configuring the Date and Time Format
1. On the Date and Time Format screen, if necessary, click Time Zone to expand the section.
A list of continents, countries, and regions is displayed. When an item proceeded with >, for example `>US', is selected, a submenu is displayed in the next column.
Figure 16 Select the time zone.
2. Expand the time zone list, as necessary, until a location with the appropriate time zone is visible.
3. Select a location with the appropriate time zone. 4. Click Submit.
Setting the Date and Time Format
1. On the Date and Time Format screen, if necessary, click Date/Time Format to expand the section.
Figure 17 Select the date and time format. 2. Select a Time Format (12 Hours or 24 Hours).
December 2021
51
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring the Date and Time Format
3. Select a Date Format:
For example, February 28, 2018 is displayed as:
DD.MM.YYYY - 28.02.2018 MM/DD/YYYY - 02/28/2018 YYYY-MM-DD - 2018-02-28 4. Click Submit.
Setting the Date and Time
1. On the Date and Time Format screen, if necessary, click Set Date/Time to expand the section.
Figure 18 Set the date and time.
2. Set the time and date. To set the time and date manually: a. Enter the time in the configured time format. b. Enter the date or select it from the calendar. To synchronize the time and date with the computer running the browser, click Now.
3. Click Submit.
December 2021
52
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Media Barcode Compatibility Checking
Enabling SNTP (Simple Network Time Protocol) Synchronization
To enable SNTP, the library must have network access to an SNTP server.
1. On the Date and Time Format screen, if necessary, click SNTP to expand the section.
Figure 19 Enable SNTP.
2. Select the SNTP Enabled check box. 3. Enter the SNTP Server address. 4. Click Submit.
CONFIGURING MEDIA BARCODE COMPATIBILITY CHECKING
The barcode media identifier is the last two characters of the barcode. The library uses the media identifier to verify the media is compatible with the tape drives installed. If the last two characters of the barcode do not match to any known identifier, then barcode is non-standard, and the barcode compatibility check is not possible.
When Barcode Media ID Restriction is enabled, the library fails a move of an incompatible tape cartridge into a tape drive. It is enabled by default. For example, an LTO-8 labeled cartridge is not allowed to move into an LTO-6 tape drive. Unknown media is treated as compatible by the library.
When Barcode Media ID Restriction is disabled, the library does not check the compatibility of a tape cartridge with the tape drives before moving it. If the cartridge is incompatible with the tape drive, the drive generates an error.
Note: It is strongly recommended that all cartridges have barcode labels with the correct media identifier, and that the Barcode Media ID Restriction is enabled.
December 2021
53
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Modify Barcode Label Checksum Type
On the Configuration > System > Media Barcode Compatibility Check screen, select or clear the Barcode Media ID Restriction and click Submit.
Figure 20 The Media Barcode Compatibility Check screen.
MODIFY BARCODE LABEL CHECKSUM TYPE
You can select the checksum behavior from the Configuration > System > Modify Barcode Label Type screen. You cannot mix checksummed and non- checksummed barcodes in a library. Checksummed barcodes are selected by default.
Figure 21 The Modify Barcode Label Type screen. From the drop-down menu, select whether the library uses Nonchecksummed barcodes or Checksummed barcodes, and then click Submit. Changing the setting initiates an inventory scan which can take several minutes to complete.
December 2021
54
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
ADD A LICENSE KEY
Add a License Key
1. To add a license key, navigate to the Configuration > System > License Key Handling screen.
Figure 22 The License Key Handling screen.
2. If necessary, click Add License Key to expand the section. 3. Enter the license key. The license key needs to have a length of 15
characters. 4. Click Add License.
Note: The button for deleting license key(s) is only available with the Service login.
December 2021
55
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring the Library Network Settings
CONFIGURING THE LIBRARY NETWORK SETTINGS
You can configure the library network settings from the Configuration > Network screen.
December 2021
Figure 23 The Configuration > Network screen.
Note: It may be helpful to have your System Administrator assist you in configuring the network settings.
1. If desired, enter a new Host Name. 2. If desired, enter a Domain Name. 3. Using the Protocol drop-down menu, select IPv4, IPv6, or both.
If you selected IPv4 or IPv4 & IPv6: a. If necessary, click IPv4 to expand the section. b. Using the Method drop-down menu, select either DHCP or Static addressing. c. If you are configuring a static IP address, enter the Address, Netmask, and Gateway addresses. d. If desired, enter DNS server information.
56
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Reset the Internal IP Range
If you selected IPv6 or IPv4 & IPv6: a. If necessary, click IPv6 to expand the section. b. Using the Method drop-down menu, select Static or Stateless. c. If you are configuring a static IP address, enter the Address, Prefix Length, and Gateway. d. If desired, enter DNS server information.
4. Click Submit.
Important To view the network settings set using the DHCP or Stateless method, use the OCP
and see Viewing Network Status on page 136.
Note: If you are using the RMI to access the Spectra Stack library and you have changed the IP address, you lose your connection to the user interface when you click Submit. To re-establish the connection, enter the new IP address in your browser and log in again.
RESET THE INTERNAL IP RANGE
For internal communication between modules, the tape library uses an Ethernet connection with an internal IP address range. To prevent any conflict between the internal IP address range and the external IP addresses, it is required to select the internal IP range before the tape library connects to the external Ethernet network.
Use the following instructions if you need to change the internal IP range after its initial configuration during the library installation:
1. Navigate to the Configuration > Network screen.
2. If necessary, click Reset Internal IP Range (in case of conflict) to expand the section and then click Submit. The library reboots. When the library completes its initialization, the Internal and External IP Conflict Prevention screen displays on the OCP.
December 2021
Figure 24 The IP Conflict Prevention Screen.
57
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Reset the Internal IP Range
3. Using the drop-down menu, select one of the three default IP address ranges that is not used by your external network.
Note: If none of the three pre-entered address ranges is suitable for use in your network, contact Spectra Logic Technical Support.
Figure 25 Select an IP address range using the drop-down menu.
4. Click Set and Proceed. The library reboots and displays the login screen (see Figure 9 on page 38).
December 2021
58
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
CONFIGURING SNMP
Configuring SNMP
Use the Configuration > Network Management screen to enable and configure SNMP (Simple Network Management Protocol), which allows applications to monitor the library. The library supports both SNMP configuration and SNMP traps.
Figure 26 The SNMP screen.
1. Select the SNMP Enabled check box to enable SNMP. When selected, the configuration entry fields become accessible.
2. In the Community Name text box, enter a string used to match the SNMP management station and the library. Both the management station and the library must use the same Community Name. The default community name is public.
3. Use the drop-down menu to select the Notification Level.
December 2021
59
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring SNMP
4. The SNMP Targets pane lists all configured SNMP targets.
To add or edit an SNMP target: a. Click Edit for the appropriate SNMP target. To add a new SNMP
target, click Edit on the row with a blank IP/Hostname. b. Enter the required information:
Field IP/Hostname Port
Version Community
Description The target IP address or hostname. The port on which to communicate with the SNMP target. The default is 162. The SNMP version supported by the SNMP target. The SNMP community string for the target.
c. Click Submit.
To delete an SNMP target:
a. Click Delete next to the target to be deleted. b. Click Submit. 5. If any targets use SNMP version SNMPv3, enter the SNMPv3 configuration options and click Submit.
Field
Description
SNMPv3 Security Levels
noAuthnoPriv -- Permits communication without authentication or privacy. authNoPriv -- Permits communication with authentication and without
privacy. authPriv -- Only permits communication with authentication and privacy.
Note: Selecting SNMPv3 does not disable SNMPv1 and SNMPv2.
Authentication User Name
The user name for authentication on the SNMPv3 trap receiver.
Authentication Password
The authentication password is needed for security levels authNoPriv and authPriv.
Authentication Protocol
The supported authentication protocols are MD5 and SHA (Secure Hash Algorithm).
Privacy/Encryption The supported privacy protocols are DES (Data Encryption Standard) and AES
Protocol
(Advanced Encryption Standard).
Privacy/Encryption The passphrase is needed for security level authPriv. Passphrase
To clear SNMPv3 configuration options, click Clear SNMPv3 Options. Click Yes when prompted to confirm this action.
December 2021
60
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Event Notification Parameters
CONFIGURING EVENT NOTIFICATION PARAMETERS
You can enable SMTP (Simple Mail Transfer Protocol) functionality and configure email notification of library events to one email address from the Configuration > Network Management > SMTP screen. The library must have network access to an SMTP server.
Figure 27 The SMTP screen.
1. Select the SMTP Enabled check box to enable SMTP. When selected, the configuration entry fields become accessible.
2. Enter the required information.
Field Notification Level
SMTP Server Security
Description
The types of events for which the library should send email. Inactive--No events are sent. Critical--Only critical events are sent. + Warnings--Only critical and warning events are sent. + Configuration--Only critical, warning, and
configuration events are sent. + Information--All events are sent.
The Hostname (if DNS is configured) or IP address (if DNS is not configured) of the SMTP server.
The security protocol for accessing the SMTP server. None SSL => SSL/TLS TLS = STARTTLS
December 2021
61
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Event Notification Parameters
Field SMTP Port
To Email Address Mailer Name Email Subject Emailer Address
Authentication Required Username Password
Description
The default port for the selected protocol is selected. You can choose one of the default ports or configure a custom port. Default SMTP Port: 25 SMTP Over SSL: 465 Alternate Port: 587 Custom - If selected, enter a port number.
The email address to receive the reported events (for example firstname.lastname @ example.com). Only one email address can be configured.
Name to display as the sender of the email.
Subject line for the email message.
The email address that displays as the sender whenever the library generates an email. This email address should uniquely identify the library to assist in troubleshooting, and be recognized by the SMTP server as a valid domain address.
When selected, a username and password are required to access the SMTP server.
User account for logging into the SMTP server when authentication is required.
Password associated with the Username when authentication is required.
3. Click Submit.
December 2021
62
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
CONFIGURING TAPE DRIVES
Configuring Tape Drives
You can see and modify drive configuration from the Configuration > Drives screen.
Figure 28 The Drives Settings screen.
Click the drive number to expand the section. The following information displays for each tape drive:
Field
Description
Drive Number Serial Number
LTO generation Drive form factor Drive interface
Tape drives are numbered from the bottom of the library up to the top beginning with "1". The drive currently hosting the SCSI communication for the library is designated with (LUN).
The serial number assigned to the tape drive by the Spectra Stack library. This serial number is reported to host applications. The serial number cannot be modified. Note: This is not the serial number assigned to the tape drive by the tape drive manufacturer; the serial number assigned by the manufacturer is shown in Manufacturer S/N.
The LTO generation of the drive.
HH - half height FH - full height
FC - Fibre Channel SAS - Serial Attached SCSI
December 2021
63
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Enabling or Disabling EE Ports
Field (Modified)
Pwr Firmware Manufacturer S/N
Power On
Port configuration (FC only)
Description
When present, this indicates that a setting has been changed, but not applied. To apply the changes, click Submit. To reset all changed fields to their previously saved values, click Undo.
Indicates whether the drive is currently powered on or off.
The version of firmware currently installed in the tape drive.
The serial number assigned to the drive when it was manufactured. Use this serial number when working with your service provider.
Selected when the drive is powered on. Note: Always power off a tape drive before removing it from the library or moving it to a new location within the library.
The drive port configuration. Speed -The currently selected Fibre Port speed. The
default is Automatic. Port Type
Automatic (default) Fabric Loop - Enables selection of the Addressing Mode. Addressing Mode - When Port Type is set to Loop, Addressing Mode can be set to Soft or Hard addressing. ALPA - When Addressing Mode is set to Hard, you can choose an ALPA address from the drop down list.
To modify the configuration of one or more tape drives: 1. Modify any of the configurable values. 2. Click Submit.
ENABLING OR DISABLING EE PORTS
The Configuration > EE Port screen lists each of the EE ports and shows whether each is enabled or disabled. Disabled EE ports are available as storage slots.
December 2021
64
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Library Partitions
Partitions do not need to have EE port slots. If a partition does not have EE port slots, the magazine must be accessed to import or export cartridges. Opening a magazine takes the library offline, while opening an EE port does not.
Figure 29 The Configuration EE Ports screen.
1. To change the EE port state, click Enable or Disable next to the appropriate module.
2. If desired, use the EE port and magazine automatic re-lock duration drop down list to change the amount of time before EE ports or magazines automatically re-lock if you do not open the door and access the EE port or magazine. The choices are 30 seconds (default) or 5 minutes.
3. Click Submit to save your selections.
CONFIGURING LIBRARY PARTITIONS
Important Partitions can only be created using the RMI (Remote Management Interface).
Partitions on the Spectra Stack library have the following restrictions: Each partition must have at least one tape drive. One drive in each
partition hosts the robotics interface (the library LUN) for the partition. The maximum number of partitions allowed is 20. Magazine slots are allocated in five-slot groups.
December 2021
65
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Library Partitions
EE ports must be enabled for a module before they can be allocated to a partition. See Enabling or Disabling EE Ports on page 64.
A partition does not need to have an EE port. If a partition does not have an EE port, the magazine must be accessed to import or export cartridges. Opening a magazine takes the library offline, while opening an EE port does not.
Although the EE port is shared between partitions, the EE port elements are assigned individually to partitions.
All of the partitions in the library go offline while partitions are configured. Ensure that host operations for all partitions are idle before running a partition wizard.
Partition configuration wizards guide you through the process. The wizards are only accessible from the RMI. Use the Basic Partition Wizard to configure partitions that have similar resources. Use the Expert Partition Wizard to configure partitions that have different resources or to adjust resource assignments for existing partitions.
Basic Partition Wizard - Any currently configured partitions are deleted. You specify the number of partitions and the wizard assigns drives and storage slots as evenly as possible to the partitions. Any extra drives or slots are assigned to the first partition.
Expert Partition Wizard - Can be used to edit or remove current partitions or create the first or an additional new partition. New partitions are created individually and you control the library resources assigned.
Using the Basic Partition Wizard
You must create at least one partition before you can use your Stack library for data backup operations. The following instructions guide you through partition creation using the Basic Wizard, which creates one or more partitions using all tape drives and licensed slots in the library.
Important With the Basic Wizard, all previously configured partitions are deleted. Ensure that
host operations for all partitions are idle before running the partition wizard.
Note: If you want to configure advanced partition settings, see Using the Expert Partition Wizard on page 70 for instructions on using the partition Expert Wizard. Use the Expert Wizard to create additional partitions without deleting current partitions, to configure partitions that have different resources or to adjust resource assignments for existing partitions.
December 2021
66
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Library Partitions
Use the instructions below to create partitions using the Basic Partition Wizard:
1. From the home screen of the library interface, select Configuration > Partitions. The Configuration screen displays.
Figure 30 The Configuration screen.
2. On the right-hand pane, select Basic Wizard. The Information screen of the Basic Wizard displays.
Figure 31 The Information screen.
December 2021
67
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Library Partitions
3. A warning displays that the Basic Wizard deletes any existing partitions. Click Proceed and then click Next. The Create Partition Scheme screen displays.
Notes:
If you want to enable or disable EE ports, click Cancel to leave the wizard and update the EE port configuration (see Enabling or Disabling EE Ports on page 64) before configuring partitions.
If the resources displayed do not match your configuration, you may need to install license keys. See Add a License Key on page 55.
December 2021
Figure 32 The Create Partition Scheme screen.
4. Use the Partition Count drop-down menu to select the number of partitions you want to create up to the maximum number of licensed partitions. With the Basic Wizard, the resources in the library (drives and media) divide evenly between each partition.
Note: Magazine slots are allocated in five-slot groups. The wizard assigns the drives and storage slots as evenly as possible to the partitions, assigning . Any extra drives or slots are assigned to the first partition.
5. Use the Barcode Label Length Reported To Host drop-down menu to select the number of digits on a tape barcode that are reported to your backup software. This option provides interchange compatibility with libraries with more limited barcode reading capabilities. The maximum barcode character length is 15 and the default is 8. This configuration applies to all partitions.
Note: The industry standard length for LTO barcode labels is eight characters. Barcode labels longer than eight characters might scan incorrectly, particularly if they are not high quality labels.
68
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Library Partitions
6. Use the Barcode Label Alignment Reported To Host drop-down menu to configure the library to report the barcode digits to the backup software starting from the left or right side of the barcode. The default setting is left. For example, when reporting only six characters of the barcode label 12345678, if alignment is left, the library reports 123456. If alignment is right, the library reports 345678. The default is left.
7. If desired, select Auto Clean to configure the library to automatically clean a tape drive when it requests cleaning using a cleaning tape stored in the partition or in an unassigned slot.
8. Click Next. The Finish Configuration screen displays with details for the partition(s) configured using the wizard.
Figure 33 The Finish Configuration screen. 9. Click Finish to create the partition(s) and exit the wizard.
December 2021
69
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Using the Expert Partition Wizard
Configuring Library Partitions
Select Configuration > Partitions > Expert Wizard to start the wizard. The Manage Partitions screen lists the current partitions, if any, and the free resources. Use this wizard to configure one partition at a time.
Notes:
If you want to enable or disable EE ports, click Cancel to leave the wizard and update the EE port configuration (see Enabling or Disabling EE Ports on page 64) before configuring partitions.
All of the partitions in the library go offline while partitions are configured. Ensure that host operations for all partitions are idle before running the partition wizard.
Figure 34 The Manage Partitions screen.
December 2021
70
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Library Partitions
Add or Edit a Partition
Use the instructions below to create partitions using the Expert Partition Wizard:
1. Click Add to create a new partition or select the partition and click Edit to edit an existing partition, and then click Next. The General Settings screen displays.
Note: The Add button is only active if there are available resources. If there are no available resources, either edit a partition to free up resources for a new partition, or remove a partition.
Figure 35 The General Settings screen.
2. Enter a Partition Name.
3. Use the Barcode Label Length Reported To Host drop-down menu to select the number of digits on a tape barcode that are reported to your backup software. This option provides interchange compatibility with libraries with more limited barcode reading capabilities. The maximum barcode character length is 15 and the default is 8. This configuration applies to all partitions.
Note: The industry standard length for LTO barcode labels is eight characters. Barcode labels longer than eight characters might scan incorrectly, particularly if they are not high quality labels.
4. Use the Barcode Label Alignment Reported To Host drop-down menu to configure the library to report from the left or right end of the barcode label to the host application when reporting fewer than the maximum number of characters.
For example, when reporting only six characters of the barcode label 12345678, if alignment is left, the library reports 123456. If alignment is right, the library reports 345678. The default is left.
December 2021
71
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Library Partitions
5. Use the Encryption Mode drop-down menu to select the type of encryption used by the partition. To disable encryption, select Controlled by Backup Application.
Note: This field is only visible if you are logged in as a security user or if the security user has configured permission for the administrator user to configure encryption used by a partition using the Expert Partition Wizard. See Configuring Encryption Key Management on page 77.
6. If desired, select Auto Clean to configure the library to automatically clean a tape drive when it requests cleaning using a cleaning tape stored in the partition or in an unassigned slot.
7. If desired, select LTO7+ Multi-initiator SCSI Conflict Detection.
LTO-7 and later generation tape drives track which hosts (SCSI initiators) send commands to the drive. When LTO7+ Multi-initiator SCSI Conflict Detection is enabled for a partition, the library monitors the initiator lists for all of the LTO-7 and later generation drives in that partition. If the library detects more than a one host system connecting to any of the tape drives in this partition, the library generates an LTO7 Multi-initiator SCSI Conflict Detection warning event. The event lists all of the host WWNNs for the given tape drive, so the administrator can remove access to any host that should not be sending commands to the drive.
Notes: The LTO7+ Multi-initiator SCSI Conflict Detection setting only appears if one or more LTO-7 or later generation drives are detected in the library.
Do not enable this feature if your storage architecture requires multiple hosts sending commands to any drive in the partition.
December 2021
72
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Library Partitions
8. Click Next. The Assign Storage Slots screen displays.
Figure 36 The Assign Storage Slots screen.
In the Assign Storage Slots screen, select the groups of slots that you want to move into or out of the partition and using the >> and << buttons make the change. Clicking Select All selects all unassigned, licensed slots. Storage slots are assigned in five slot groups and are displayed in the format module.slot-module.slot where:
module - The module number. Modules are numbered based on their location in the physical library. The bottom module is Module 1.
slot - The slot number as shown in Figure 6 on page 29.
December 2021
73
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Library Partitions
9. Click Next. If you have enabled EE ports (see Enabling or Disabling EE Ports on page 64), the Assign EE Ports screen displays.
Figure 37 The Assign EE Ports screen.
In the Assign EE Ports screen, use the >> and << buttons to assign EE ports to the new partition. EE Port locations are shown in the format module.slot-module.slot where:
module - The module number. Modules are numbered based on their location in the physical library. The bottom module is Module 1.
slot - The slot number as shown in Figure 6 on page 29. Note: The EE port can be shared by partitions, but individual slots
cannot. Importing or exporting cartridges in a partition without assigned EE slots requires magazine access, which takes all partitions in the library offline. EE port access does not take partitions offline.
December 2021
74
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Library Partitions
10. Click Next. The Assign Drives screen displays.
Figure 38 The Assign Drives screen. 11. In the Assign Drives screen, use the >> and << buttons to assign drives
to the new partition. 12. Click Next. The Select Library LUN Drive screen displays.
Figure 39 The Select Library LUN Drive screen. 13. If the partition has multiple tape drives, select the drive to host the SCSI
communication for the partition. Note: The lowest numbered drive in the partition is selected as the
default.
December 2021
75
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Library Partitions
14. Click Next. The Finish Configuration screen displays.
Figure 40 The Finish Configuration screen.
15. Verify the partition configuration and then click Finish. After the wizard creates or reconfigures the partition, the library comes online automatically.
Remove a Partition
1. On the Manage Partitions screen (see Figure 34 on page 70), select the partition to remove.
2. Click Remove, and then click Next. 3. Verify that you want to remove the partition and click Finish.
After the wizard removes the partition, the library comes online automatically.
December 2021
76
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
CONFIGURING ENCRYPTION KEY MANAGEMENT
The Configuration > Encryption screen displays the available data encryption key manager types.
Notes: Encryption configuration changes cannot be made while media is loaded in any drive in the library.
Encryption configuration is only accessible from the RMI.
By default, to configure encryption, you must be logged in as the Security user. The security user can allow the administrator user to configure the type of encryption assigned to a partition.
December 2021
Figure 41 The Encryption screen.
Set the general encryption settings as required. If you are making multiple changes, you can select all changes and then click Submit once. To change the configured default encryption mode for a new partition,
select the encryption mode and then click Submit at the bottom of the page. To apply the default settings to all existing partitions, click Apply to all existing partitions and then click Submit at the bottom of the page. By default, only the security user is allowed to change encryption configurations. To allow the administrator user to change encryption settings select the Allow Administrator encryption configuration during Expert Partition Wizard check box and then click Submit at the bottom of the page. The encryption mode can be configured for each partition in the Set Encryption Mode per Partition pane. Select the encryption mode for each partition and then click Submit.
77
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring KMIP
Configuring Encryption Key Management
If you plan to use KMIP encryption key management in some or all of your partitions, use the Key Management Interoperability Protocol (KMIP) Wizard to configure use of KMIP key management servers with the library. Access to the wizard from the Encryption menu on the RMI is only available to the Security user and requires the KMIP license key (see Add a License Key on page 55).
For additional information on configuring KMIP servers for use with the library, see the documentation that came with your KMIP server.
Before running the wizard, verify that:
The library configuration is complete, including defining all library partitions.
The KMIP server is available on the network and has been configured for use with this library.
Use the following instructions to set up KMIP encryption management.
1. Select Configuration > Encryption > KMIP Wizard. The Wizard Information screen displays.
Figure 42 The KMIP Wizard Information screen.
December 2021
78
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
2. To disable KMIP encryption, click Clear All Wizard Settings. To set up KMIP encryption, click Next. The Certificate Authority Information screen displays.
Figure 43 The Certificate Authority Information screen.
3. Ensure that all prerequisites for using the KMIP certificate are met and click Next. The Certificate Authority Certificate Entry screen displays.
Figure 44 The Certificate Authority Certificate Entry screen.
December 2021
79
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
4. Follow the on-screen instructions to obtain and copy the certificate from the KMIP server management console. Paste the certificate into the wizard and then click Next. The Library Certificate Information screen displays.
Figure 45 The Library Certificate Information screen.
5. The Library Certificate Information screen displays information about the next wizard steps. Click Next. The KMIP Client Configuration screen displays.
Figure 46 The KMIP Client Configuration screen.
6. The KMIP Client Configuration screen provides options for two types of server authentication.
If your KMIP server uses a client username and password for authentication, enter the username and password that were specified on the KMIP management console for the library. This si recommended if available.
If your KMIP server uses only certificate passing for authentication, select Enable KMIP Certificate-only authentication. Only select this option if you are using a KMIP server that requires it and you do not have a client username and password.
December 2021
80
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
Click Next. The Certificate Generation screen displays.
Figure 47 The Certificate Generation screen.
7. The Certificate Generation screen displays the current library certificate, if one exists. To use the current certificate, select Keep Current Certificate and then click Next. The KMIP Server Configuration screen displays. Skip to Step 9 on page 82.
To generate a new certificate, select Generate New Certificate. The wizard generates and displays a new library certificate. Click Select Certificate and press CTRL-C to copy the new certificate text, and then click Next. The Sign Library Certificate screen displays.
December 2021
Figure 48 The Sign Library Certificate screen.
81
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
8. Sign the new library certificate with the certificate authority as a client certificate. Press CTRL-V to paste the new KMIP certificate in the box, and then click Next. The KMIP Server Configuration screen displays.
Figure 49 The KMIP Server Configuration screen.
9. In the KMIP Server Configuration screen, enter the IP address or fully- qualified hostname and port number for up to ten KMIP servers. To verify access to the KMIP server(s), click Connectivity Check. Click Next to continue. The Setup Summary screen displays.
Figure 50 The Setup Summary screen.
10. The Setup Summary screen displays the settings that were configured by the wizard. Verify that the settings are correct and that no errors display in the Done column. If you need to modify any settings or fix any issues, either click Back to reach the applicable screen or Cancel out of the wizard to fix the issues and return later. When the setting are all correct, click Finish. The Configuration > Encryption screen displays (see Figure 41 on page 77).
December 2021
82
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
11. Use the Set Encryption Mode per Partition pane to select KMIP as the encryption mode for the desired partition(s) and then click Submit.
-- OR --
If you want all partitions to use KMIP Encryption, select KMIP as the default encryption mode, click Apply to all existing partitions, and click Submit.
Using Encryption Standard
Log Into Encryption Standard
Only the security user can add, import, or export encryption keys, and set the Encryption User Password. If allowed by a security user, the administrator user can configure the type of encryption assigned to a partition.
1. Log into the library as the security user. Select Configuration > Encryption > Encryption Standard. The Encryption User Login screen displays..
Figure 51 Enter the encryption user password to access the encryption feature.
December 2021
83
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
2. Enter the encryption password and then click Login. Note: If the Encryption Password was never set, the password is blank.
The Configuration > Encryption > Encryption Standard screen displays.
Figure 52 The Encryption Standard screen.
Set or Change the Encryption Password
1. Access the encryption feature (see Log Into Encryption Standard on page 83). The Configuration > Encryption > Encryption Standard screen displays (see Figure 52 on page 84).
2. To set or change the current encryption user password, enter and confirm the desired Encryption User Password and click Submit.
Create an Encryption Key
1. Access the encryption feature (see Log Into Encryption Standard on page 83). The Configuration > Encryption > Encryption Standard screen displays (see Figure 52 on page 84).
December 2021
84
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
2. Click Add Key. The Add Key dialog box displays.
Note: Encryption Standard only supports using one encryption key at a time. The Import Key and Add Key buttons do not display if there is already an encryption key stored in the library. If you delete the existing key, as described in Deleting an Encryption Key from the Library on page 98, they display again.
Figure 53 Enter a moniker to create a new encryption key.
December 2021
85
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
3. Enter a name for the encryption key in the Moniker field. Make sure that the moniker meets the following requirements:
A moniker can be any combination of the numbers 0�9, lower and upper case alphabetic characters (a � z and A � Z), and the at symbol (@), dash (�), underscore (_), and period (.) characters, with a maximum of 32 characters. To improve readability, use an underscore to separate words. Do not use any space characters.
Each moniker must be a unique string of characters not used for any other encryption key.
Recommended--Make a habit of using a single case (all upper or all lower) for monikers. After the encryption key is created and exported, the library ignores the case used in the moniker.
For example, the library interprets Spectra1, spectra1, and SPECTRA1 as the same moniker when importing a key. However, the key generated by each variation is unique.
Caution
If you create two monikers that are identical except for case, you are not able to retrieve your data after importing or creating a key using a different variation of the moniker.
4. Click Submit. The Configuration > Encryption > Encryption Standard screen displays showing the moniker for the newly created encryption key.
Note: If the key is not yet assigned to a partition, N/A displays in the Primary Key For column.
Figure 54 The new encryption key is listed in the Encryption Key Handling pane.
5. Export the newly created encryption key and save it to a secure location (see Export the Encryption Key on page 90).
Caution
If you lose the encryption key, data encrypted using the key cannot be recovered. For this reason, promptly copying the key and storing it safely (that is, away from
the data encrypted using the key) is extremely important to data decryption and
recovery. See Exporting and Protecting Encryption Keys on page 89 for additional
information.
December 2021
86
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
Enable Encryption Standard in a Partition
How you enable Encryption Standard in a partition depends on whether you are a security user or an administrator user with permission to configure partition encryption using the Expert Partition Wizard.
Note: All of the partitions in the library go offline while partitions are configured. Ensure that host operations for all partitions are idle before running the partition wizard.
Security User
1. Navigate to Configuration > Encryption to access the main encryption screen.
Figure 55 The Encryption screen.
2. In the Set Encryption per Partition pane, select Encryption Standard next to the partition for which you want to enable encryption and click Submit. The partition is updated to use the currently stored encryption key to encrypt and decrypt data in the partition.
-- OR --
If you want all partitions to use Encryption Standard, select Encryption Standard as the default encryption mode, click Apply to all existing partitions, and click Submit.
December 2021
87
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
Administrator User
1. Select Configuration > Partitions > Expert Wizard to start the Expert Partition Wizard. The Manage Partitions screen lists the current partitions.
Figure 56 The Manage Partitions screen.
2. Select the partition for which you want to enable Encryption Standard, click Edit, and then click Next. The General Settings screen displays.
Figure 57 The General Settings screen.
December 2021
88
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
3. Using the Encryption Mode drop-down menu, select Encryption Standard to enable encryption.
Note: This field is only visible if you are logged in as a security user or if the security user has configured permission for the administrator user to configure encryption used by a partition using the Expert Partition Wizard. See Configuring Encryption Key Management on page 77.
4. Click Next to advance through the remaining screens in the wizard. The partition is updated to use the currently stored encryption key to encrypt and decrypt data in the partition.
Exporting and Protecting Encryption Keys
Creating a backup of all keys used in the library and a record of the password for each exported key is essential to ensuring that you can recover encrypted data. For safe-keeping and security, export the encryption key and store it in a safe, secure location so that you can import it back into the library if needed.
Overview Decrypting encrypted data requires both the encryption key and the encryption key password used to protect the encryption key when it is exported. To ensure that the keys are protected, use the Export Key option described in this section to export encryption keys as soon as possible after you create them.
Caution
Data cannot be recovered without the encryption key used to encrypt the data, so protecting encryption keys is extremely important to data decryption and recovery.
To decrypt and restore encrypted data, you need the data, the encryption key, and
the encryption key password used to protect the exported key.
Best Practice Spectra Logic recommends that you export each encryption key to at least two different USB devices and store them in separate locations. Remember, lost encryption keys cannot be recreated; keep them as secure (and as backed up) as your data.
Caution
As a matter of best practice, Spectra Logic recommends exporting encryption keys to a USB device instead of using email or RMI download.
Although emailing and RMI download of encryption keys are supported by the library, they present security issues, including the following:
Copies of encryption keys may be left on the email servers used for sending and receiving email and are thus subject to compromise.
The difficulty in verifying where all of the copies of emailed or downloaded encryption keys may be located can make security audits more challenging.
December 2021
89
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
Export the Encryption Key
Use the following steps to export the current encryption key:
1. Access the encryption feature (see Log Into Encryption Standard on page 83).
2. If you want to export the encryption key to a USB device, plug a USB device into the USB port on the Controller Module.
3. From the Configuration > Encryption > Encryption Standard screen, click Export Key. The Export Key dialog box displays.
Export Type RMI Download Mail Key to
USB key
December 2021
Figure 58 The Export Key dialog box.
4. On the Export Key screen, enter and verify a password using any combination of the numbers 0�9, lower and upper case alphabetic characters (a�z and A-Z), and the at symbol (@), dash (�), underscore (_), and period (.) characters. This password is used to encrypt the exported key.
5. Select the desired export option and click Submit. An export status screen briefly displays.
Description
Save the exported key to the default location for the browser used for RMI access.
Sends the encryption key as an email attachment to the email address provided. Note: To use this option, SMTP must be enabled and the SMTP server entered. See Configuring Event Notification Parameters on page 61.
Saves the exported encryption key to the USB device connected to the Controller Module.
90
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
6. Make a record of the encryption key password; you need it to import the key back into the library. Without the password, you cannot import the key, and the data encrypted using the key is inaccessible.
Caution
Do not lose the encryption key password. Without it, you cannot reimport an encryption key after it is deleted from the library, and the data encrypted using the
key is inaccessible.
December 2021
7. Confirm that the encryption key was correctly exported.
If you exported the encryption key using an RMI download -- Confirm the file exported correctly as described in Verify the Exported Encryption Key.
If you exported the encryption key to a USB device--Immediately confirm that the encrypted key copied correctly by clicking Check Key Files (see Figure 54 on page 86) and following any prompts. If desired, save or print the Check Key Files report for an audit record showing that the USB device was readable, and that the destination key matched the source key. Use the steps in Verify the Exported Encryption Key to provide a second confirmation.
If the confirmation indicates the key did not copy correctly, delete all data from the USB device so that no trace of the failed export file remains, and then export the key again using a different USB device, beginning with Step 2 on page 90.
If you exported the encryption key using email--Confirm the receipt of the email with the attachment by contacting the user to whom you sent the encrypted key file. Confirm that the email attachment contains a key file as described in Verify the Exported Encryption Key.
Verify the Exported Encryption Key
After exporting an encryption key, verify that the export was successful as soon as possible.
When Exported as RMI Download
1. Locate the file called name.bsk where name is the moniker you assigned to the key when it was created.
2. Make sure that the file is more than 0 bytes in size. If the file meets these requirements, the encryption key was successfully exported and is usable.
If the exported key file is not present or if the file is 0 bytes in size, repeat the export process as described in Export the Encryption Key on page 90.
3. If desired, print or save a screen capture showing the attachment name and file size for an audit record showing that the file was saved, and that the key file contained information.
91
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
When Saved to a USB Device
1. Plug the USB device into a computer.
2. Examine the contents of the USB device to verify that it contains a file called name.bsk where name is the moniker you assigned to the key when it was created.
3. Make sure that the file is more than 0 bytes in size. If the file meets these requirements, the encryption key was successfully exported and is usable.
If the exported key file is not present or if the file is 0 bytes in size, repeat the export process as described in Export the Encryption Key on page 90 using a different USB device.
4. If desired, save or print a screen capture of the USB directory for an audit record showing that the USB device was readable, and that the key file contained information.
5. Store the USB device in a safe location.
When Sent as an Email Attachment
1. Open the email attachment and verify that it contains a file called name.bsk where name is the moniker you assigned to the key when it was created.
2. Make sure that the file is more than 0 bytes in size. If the file meets these requirements, the encryption key was successfully exported and is usable.
If the email attachment does not contain the exported key file or if the file is 0 bytes in size, repeat the export process as described in Export the Encryption Key on page 90.
3. If desired, print or save a screen capture showing the attachment name and file size for an audit record showing that the file was received, and that the key file contained information.
4. Save the email attachment to a safe location from which you can copy it to a USB device, if needed.
Protect the Encryption Key
In conformance with your security plan, track the location of each USB device containing the exported key or the name of each person who received the email message with the exported key file attached. Also keep track of the password you used when you exported the key.
Caution
Make sure you keep a record of the password created when exporting the key. You must have this password and the encrypted file containing the exported key in
order to import the encryption key back into the library. Without the key password,
you are not able to import the encryption key.
December 2021
92
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
Important Backup files of the library configuration include any encryption keys that were
stored in the library at the time the file was created.
The following guidelines outline the essential tasks required to protect encryption keys:
Save one or more copies of every key using the Key Export option on the Encryption Configuration screen (see Export the Encryption Key on page 90).
Caution
As a matter of best practice, Spectra Logic recommends exporting encryption keys to a USB device or RMI download instead of using email.
Although emailing encryption keys is supported by the library, doing so presents security issues, including the following:
Copies of encryption keys may be left on the email servers used for sending and receiving email and are thus subject to compromise.
The difficulty in verifying where all the copies of emailed encryption keys may be located can make security audits more challenging.
If you choose to store only a single copy of an encryption key, make sure that you keep the copy secure. If something happens to the device where you stored the exported key and the key was deleted from the library, both the key and all data encrypted using the key are unrecoverable.
Caution
To emphasize: If you lose the encryption key or the password for the exported file, your data is unrecoverable if the key was deleted from the library. You need to
balance the number of copies of the key to store to guarantee access to the encrypted
data against the security risk associated with storing multiple keys. Make sure that the
key was successfully exported prior to removing a key from the library.
Store encryption keys offsite in a location other than the site used for media storage. Confirm that the key is stored correctly on the USB device or was received by the intended recipient before deleting the key from your library. If you delete the key, you must import the key back into the library in order to decrypt the data that was encrypted using the key. Importing keys is described in Import the Required Key Into the Library on page 95.
You may want to make two copies of a key, storing each in a secure location. Keep a record of each key's location so that you can easily find the key when you need to restore or delete data.
Maintain a list of every password associated with each key and securely store the list. Never keep this list as cleartext (unencrypted text) on a networked computer, or send it through email as cleartext. For added security, encrypt the file containing the list of passwords.
December 2021
93
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
Track every copy of each key. This tracking is critical in order to meet requirements that may govern data retention and data destruction. Destroying all exported copies of keys associated with encrypted data AND deleting the keys from the library is sufficient to satisfy data destruction requirements, since encrypted data cannot be accessed without the key used to encrypt it.
Spectra Logic recommends tracking the information listed in the following table for every key that you create. For added security, encrypt the file containing the tracking information.
Key moniker: Number of key copies: Location of each copy: Password(s) associated with exported copy of the moniker: Location of cartridges containing data encrypted using this moniker: Moniker creation date: Planned expiration date:
Restoring Encrypted Data
Overview Restoring encrypted data from a cartridge follows the standard data restore processes that you use with your storage management software. The only difference is that the key used to encrypt the data being restored needs to be stored in the library and assigned to the partition in which the encrypted cartridge is loaded. If the key is already stored on the library and assigned to the partition containing the encrypted tape(s), the data is automatically decrypted as it is read from tape; if the encryption key is not currently stored on the library, it must be imported and assigned to the partition before the data can be decrypted. Once the required encryption key is assigned to the partition, standard restore procedures are unchanged.
Use the Key Stored in the Library
This section describes how to restore data if the key used to encrypt the data is currently stored in the library.
Note: If the data was not encrypted using the currently loaded key, the library prompts you with the moniker of the key that is required to decrypt the data. You must import the key as described in Import the Required Key Into the Library before the data can be restored.
December 2021
94
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
If the encryption key is not currently assigned to the partition, modify the partition as described in Enable Encryption Standard in a Partition on page 87. If the encryption key is assigned to a partition, continue with the following steps.
1. If necessary, import the cartridges containing the data to be restored into the library partition to which the encryption key is assigned.
2. Use your storage management software to restore the data. The data is automatically decrypted using the stored key.
Import the Required Key Into the Library
If the encryption key required for a specific set of encrypted data is not present in the library, the library prompts you with the moniker of the key that is required to decrypt the data. Use the key moniker to identify the required encryption key and then import the key into the library as described in this section. After you assign the imported key to the partition containing the encrypted cartridge, the data on the cartridge is decrypted when read from tape.
Important In addition to the file containing the exported key, you need the key password in
order to import the key into the library. Without the key password, you are not able to import the encryption key.
Note: If an encryption key is already stored in the library, you must first delete that key as described in Deleting an Encryption Key from the Library on page 98. You can then import another key.
Use the following steps to import a key from the RMI or a USB device:
1. If you are importing the key from a USB device, plug the USB device containing the exported encryption key you want to import into the Controller Module.
December 2021
95
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
2. Access the encryption feature (see Log Into Encryption Standard on page 83). The Configuration > Encryption > Encryption Standard screen displays.
Figure 59 The Encryption Standard screen. 3. Click Import Key. The Import Key dialog box displays.
Figure 60 The Import Key dialog box.
December 2021
96
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
4. If you select Import key over RMI, the dialog box updates. Use your browser to locate the key file and enter the password used to export the key file and then click Submit.
Figure 61 Import a key over RMI.
If you select Import key from USB, the dialog box updates to show all key files found on the USB device. Select the file you want to import, enter the password used to export the key, and click Submit.
December 2021
Figure 62 Import a key from USB.
5. When the key import completes, the Configuration > Encryption > Encryption Standard screen displays, showing the moniker of the newly imported key (see Figure 54 on page 86).
6. Assign the imported key to the partition which contains the encrypted cartridge (see Enable Encryption Standard in a Partition on page 87).
7. Use your storage management software to restore the data.
97
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
Deleting an Encryption Key from the Library
Overview BlueScale Encryption Standard Edition only supports storing a single encryption key in the library. You must first delete the key currently stored in the library before you can create or import a new key and assign it to one or more partitions.
Caution
Make sure that you export a copy of the existing key before you delete it. You need a copy of the exported key and its password to import the key back into the library
and restore data that was encrypted with the key.
Important Backup files of the library configuration include any encryption keys that were
stored in the library at the time the file was created.
Use the following steps to delete a key:
1. Access the encryption feature (see Log Into Encryption Standard on page 83).
2. Export at least one copy of the key and store it in a safe location (see Export the Encryption Key on page 90).
3. If the encryption key you plan to delete is assigned to a partition, edit the partition to disable encryption (see Disabling Encryption in a Partition on page 99).
Note: If you delete an encryption key that is assigned to a partition you are not able to encrypt or decrypt data in that partition until you re-import the key.
4. From the Configuration > Encryption > Encryption Standard screen (see Figure 54 on page 86), click Delete Key next to the key you want to remove from the library. The Delete Key confirmation dialog box displays.
December 2021
Figure 63 The Delete Key confirmation dialog box.
5. Click Yes to delete the key. 6. A key deletion successful message briefly displays and then the
Configuration > Encryption > Encryption Standard with the moniker is no longer listed on the screen.
98
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
Disabling Encryption in a Partition
How you disable encryption in a partition depends on whether you are a security user or an administrator user with permissions to configure partition encryption using the Expert Partition Wizard.
Note: All of the partitions in the library go offline while partitions are configured. Ensure that host operations for all partitions are idle before running the partition wizard.
Security User
1. Navigate to Configuration > Encryption to access the main encryption screen.
Figure 64 The Encryption screen.
2. In the Set Encryption per Partition pane, select Controlled by Backup Application next to the partition for which you want to disable encryption and click Submit. The partition is updated.
-- OR --
If you want to disable encryption in all partitions, select Controlled by Backup Application as the default encryption mode, click Apply to all existing partitions, and click Submit.
December 2021
99
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configuring Encryption Key Management
Administrator User
1. Select Configuration > Partitions > Expert Wizard to start the wizard. The Manage Partitions screen lists the current partitions.
Figure 65 The Manage Partitions screen.
2. Select the partition in which you want to disable encryption, click Edit, and then click Next. The General Settings screen displays.
Figure 66 The General Settings screen.
December 2021
100
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configure User Accounts
3. Using the Encryption Mode drop-down menu, select Controlled by Backup Application to disable encryption.
Note: This field is only visible if you are logged in as a security user or if the security user has configured permission for the administrator user to configure encryption used by a partition using the Expert Partition Wizard. See Configuring Encryption Key Management on page 77.
4. Click Next to advance through the remaining screens in the wizard.
CONFIGURE USER ACCOUNTS
Configure User Account Settings
Logged in as a Security user or an Administrator user, from the Configuration > User Accounts > User Accounts Settings screen you can set the password rules that apply for all users.
Note: When the settings are changed, they are applied to new passwords. Existing passwords remain the same.
Figure 67 The User Account Settings screen.
December 2021
101
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configure User Accounts
Configure Password Rules
Select any password rules that you want to apply and then click Submit.
Minimum Number Of Characters--Choose the minimum password length. The factory default value is 8. Possible range for this option is from 8 to 20. The maximum password length is 128.
Minimum Number Of Upper Case Alphabetic Characters (A-Z)-- Choose the minimum number of upper case alphabetic characters. The factory default value is 0. Possible range for this option is from 0 to 3.
Minimum Number Of Lower Case Alphabetic Characters (a-z)-- Choose the minimum number of lower case alphabetic characters. The factory default value is 0. Possible range for this option is from 0 to 3.
Minimum Number Of Numeric Characters (0-9)--Choose the minimum number of numeric characters. The factory default value is 0. Possible range for this option is from 0 to 3.
Minimum Number Of Special Characters (!@#$%^&*()_+-={}|[]\;: <>?,./) -- Choose the minimum number of special characters. The factory default value is 0. Possible range for this option is from 0 to 3.
Maximum Number Of Identical Consecutive Characters--Choose the maximum number of identical consecutive characters. The factory default value is unlimited. Possible range for this option is from 1 to 3, or unlimited.
Maximum Number Of Failed Logins Before Password Is Locked-- Choose the maximum number of failed logins before the password is locked. The factory default value is unlimited. Possible range for this option is from is from 1 to 10, or unlimited.
Caution
When a password is locked, the login cannot continue. Either the user must complete a valid login with an administrator account where the administrator can change a password or request a temporary password.
Maximum Number Of Days Before Password Must Be Changed-- Choose the maximum number of days before the password must be changed. The factory default value is unlimited. Possible range for this option is from is from 1 to 365, or unlimited.
Number Of Password Changes Before An Old Password Can Be Used Again --Choose the number of password changes before the password can be re-used. The factory default value is 0. Possible range for this option is from is from 1 to 6.
December 2021
102
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configure User Accounts
Allow Magazine/EE Port access by the "User role"
By default, only the administrator and security users are allowed to open the EE Ports or magazines. The administrator and security users can enable accounts with the user role to access to the magazines and EE Ports. Select the desired access permission(s) and click Submit.
To allow access the magazines, select Allow magazine access by the "User role".
To allow access to the EE Ports, select Allow EE Port access by the "User role".
Configure Local User Accounts
From the Configuration > User Accounts > Local User Accounts screen you can add local users or set a new password for the user, administrator, or security accounts.
Notes: An Administrator user can add a user or change the password for a user with an administrator or user role.
A Security user can add a security user or change the password for a security user.
A user with the user role cannot access this screen.
Figure 68 The Local User Accounts screen (Administrator logged in).
December 2021
103
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configure User Accounts
Change Passwords
1. Click Edit next to the user for which you want to change the password. The Modify User Password dialog box displays.
Notes: A password is not required for the default user account.
The library initially has a null administrator password. A password must be set using the OCP before the Administrator can access the library from the RMI. Once the Administrator password has been set from the OCP, it can be changed by the Administrator user from either the OCP or RMI.
The default password for the Security user is security. The password must be modified using the OCP before the Security user can access the library from the RMI. Once the Security password has been set from the OCP, it can be changed by the Security user from either the OCP or RMI.
Figure 69 The Modify User Password dialog box.
2. Enter and verify the new password, and then click Modify. The dialog box closes to display the Local User Account screen.
December 2021
104
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configure User Accounts
Add a User
1. From the Configuration > User Accounts > Local User Accounts screen (see Figure 68 on page 103), click Add User. The Add User screen displays.
Figure 70 The Add User screen (Administrator logged in).
2. Enter the Name for the user.
3. Select a Role for the user:
User -- A user account allows access to library status information and does not allow access to configuration, maintenance, or operation features. A password is not required for the default user account, but is required for additional user accounts.
Administrator -- The Administrator account allows access to all configuration, maintenance, and operation features other than encryption.
Security -- A security user has access to all administrator functionality and can also configure security features and change the security user password.
4. Enter and verify the password. The password must meet the configuration options selected in Configure User Account Settings on page 101.
5. Click Add. The dialog box closes to display the Local User Accounts screen.
December 2021
105
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configure LDAP
Configure User Accounts
From the Configuration > User Accounts > LDAP screen, manage LDAP (Lightweight Directory Access Protocol) servers and users.
Figure 71 The Configuration > User Accounts > LDAP screen.
December 2021
106
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configure User Accounts
Add Server
To add an LDAP server, click Add Server, the Add Server dialog box displays.
December 2021
Figure 72 The LDAP Add Server dialog box.
1. Enter the information for the primary server.
Field Host Port User CN
User DN
Description
The IP address for the LDAP server.
The port on which to communicate with the host. The default is 389.
The common name for a user with permission to connect to the LDAP server. Many environments use the format "Surname, Name" or the email address for a group of library administrators.
The distinguished name for the user with the entered User CN. For example: DC=Examplegroup,DC=local.
107
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configure User Accounts
Field Password
Use SSL
Description
The password for the user with the entered User CN. This password might be the User CN's Windows password or an environment-specific password.
If required, select Use SSL and then paste the appropriate CA certificate.
2. Enter the Secondary/Backup Server Host address and Port number.
3. Enter the Base DN for Distinguished Names. These are the LDAP parameters needed to identify the LDAP domain. For example: OU=users,DC=Examplegroup,DC=local.
4. In the Attribute Mapping pane, enter the LDAP Server Name for the specified user account.
5. Click Test Connection to verify the server configuration.
6. After verifying the server configuration, click OK.
December 2021
108
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Configure User Accounts
Add User
To add an LDAP user, click Add User, the Add User dialog box displays.
Figure 73 The LDAP Add User dialog box.
1. Click Query LDAP Servers to see a list of available users. 2. Select a user name and then assign the user a Role (User, Administrator,
or Security). 3. Click OK.
December 2021
109
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
WEB MANAGEMENT
Web Management
Use the instructions in this section to configure advanced web management features for the RMI.
Enabling SSL or SSH
Enable or disable secure access to the RMI using Secure Socket Layer (SSL) or Secure Shell (SSH) from the Configuration > Web Management screen. When SSL is enabled, connections to the RMI must use HTTPS. The
default is disabled. When SSH is enabled, the library accepts SSH connections. The default
is enabled.
Figure 74 The SSL/SSH pane of the Configuration > Web Management screen.
Select or clear the SSL and SSH check boxes as desired, and click Submit.
December 2021
110
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Security Certificates
Web Management
From the Configuration > Web Management screen select certificate settings and manage security certificates.
Figure 75 The Security Certificate panes of the Configuration > Web Management screen.
Select Certificate Settings
On the Configuration > Web Management screen (Figure 75), select Use Self Signed Certificate or, if a custom certificate is available, Use Custom Certificate, and click Submit. If you want to use a custom certificate, but one is not available, continue with Add a Security Certificate on page 112.
December 2021
111
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Web Management
Add a Security Certificate
Use the following instructions to add a security certificate.
1. On the Configuration > Web Management screen, click Start Certificate Wizard to start the wizard. The Information screen displays.
Figure 76 The Certificate Wizard Information screen.
2. If you want to clear all current wizard settings before continuing, click Clear All Wizard Settings.
3. Click Next to continue. The Certificate Signing Request screen displays.
December 2021
Figure 77 The Certificate Signing Request screen.
112
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Web Management
4. Enter the Certificate Request Data and click Generate CSR. The certificate displays in the Certificate Sign Request pane.
5. Click Select CSR and copy the certificate. Provide the certificate you copied to your Certificate Authority. Once the certificate is signed, select and copy the entire certificate, and then click Next. The Signed Certificate screen displays.
Figure 78 The Signed Certificate screen.
6. Paste the certificate in the Signed Certificate pane and click Next. The Finish screen displays.
Figure 79 The Finish screen. 7. Click Finish to save the certificate and end the wizard.
December 2021
113
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Web Management
Backup Custom Certificate
Once you have saved a custom security certificate, click Backup Custom Certificate (see Figure 75 on page 111) and use your browser to save the file.
Restore Custom Certificate
To restore a previously saved custom certificate, click Browse and use your browser to locate the certificate file. Then click Restore Custom Certificate (see Figure 75 on page 111).
Session Timeout
On the Configuration > Web Management screen, use the Session Timeout pane to configure the session timeout for the RMI/OCP.
Figure 80 The Session Timeout pane of the Configuration > Web Management screen.
Using the drop-down, select how long the user should remain logged in (5 or 30 Minutes) and click Submit.
OCP/RMI Session Locking
The library supports only one OCP or RMI session at a time for Administrator, Security, or Service users. By default, when a new user logs in to the RMI or OCP, the existing user session is terminated. Use the OCP/ RMI Session Locking pane of the Configuration > Web Management screen to change this behavior.
December 2021
Figure 81 The OCP/RMI Session Locking pane of the Configuration > Web Management screen.
114
User Guide--Spectra Stack Library
Chapter 3 -- Configuring the Library
Web Management
When OCP/RMI Session Locking is enabled, a new session does not terminate the current session and the new user will not be able to log in. Select the OCP/RMI Session Locking check box and click Submit to enable this option.
Restrict RMI Access
To restrict RMI access for the administrator and security users, in the Restricted Remote Management Interface (RMI) Login pane of the Configuration > Web Management screen, select the Restricted Remote Management Interface (RMI) Login check box and click Submit.
Figure 82 The Restricted Remote Management Interface (RMI) Login pane of the Configuration > Web Management screen.
This can be used in high security environments where policies require all configuration changes to occur from the physical library front panel.
Note: Many settings cannot be configured from the OCP.
The user and service users are still able to log in with the RMI. To remove all RMI access, unplug the Ethernet cable from the library controller.
December 2021
115
User Guide--Spectra Stack Library
CHAPTER 4
Operating the Library
This chapter contains instructions for using your Spectra Stack tape library. Click Operations on the Home screen to access the operations features.
Topic Moving Media
Filtering Based on Barcode Moving a Cartridge Opening the EE Port Opening a Magazine Cleaning a Tape Drive Rescanning the Cartridge Inventory Forcing a Drive to Eject a Cartridge
page 117 page 117 page 118 page 118 page 119 page 121 page 121 page 122
116
Chapter 4 -- Operating the Library
MOVING MEDIA
Moving Media
You can move a tape cartridge located in a source element to an available destination element within the same partition from the Operation > Move Media screen.
Figure 83 The Move Media screen.
Source Elements - Tape drives, enabled EE ports, and storage slots that contain a tape cartridge
Destination Elements - Tape drives, enabled EE ports, and storage slots that do not contain a tape cartridge
Tape drives are in the order of their drive numbers. Tape drives are numbered from the physical bottom of the library starting with Drive (1).
Slots are listed in the order of the slot numbers. Slots are numbered (m.s), where m is the module number and s is the slot within the module. For example, the tape numbered (1, 5) is present in the 5th slot of the first module.
Filtering Based on Barcode
To see a subset of the cartridges in the library based on tape barcodes, enter some or all of the barcode label characters in the search area, and click Search. The Source Element list updates to display only the cartridges with labels that include the characters in the search box.
To perform a different search or display all of the available cartridges, click Barcode Filter Off.
December 2021
117
User Guide--Spectra Stack Library
Chapter 4 -- Operating the Library
Moving a Cartridge
Opening the EE Port
1. Select the cartridge from Source Elements. 2. Select the destination element from Destination Elements. 3. Click Submit.
OPENING THE EE PORT
From the Home screen, click Open EE Port or navigate to Operations > Open EE Port to see the status of EE port(s) and open any enabled EE port in the library. An EE port must be enabled before it can be opened. To enable an EE port, see Enabling or Disabling EE Ports on page 64. To determine which magazine slots belong to a partition, see Using Partition Map Graphical View on page 130.
Figure 84 The Open EE Port screen.
To open an EE port, click Open for the appropriate EE port. The library releases the lock. Open the door in the appropriate module and then pull the EE port out of the library to access the EE slots. Close the magazine access door after reinserting the EE port.
WARNING
Hazardous moving parts exist inside this product. Do not insert tools or any portion of your body into the interior of the library through the EE port door.
December 2021
118
User Guide--Spectra Stack Library
Chapter 4 -- Operating the Library
Opening a Magazine
Note: If you do not open the door and access the EE port within the automatic re-lock duration, the EE port re-locks. See Enabling or Disabling EE Ports on page 64 to change the automatic re-lock duration.
Figure 85 Pull the EE Port magazine out of the library.
OPENING A MAGAZINE
You can unlock any magazine in the library from the Operation > Open Magazine screen. To determine which magazine slots belong to a partition, see Using Partition Map Graphical View on page 130.
Figure 86 The Open Magazine screen.
December 2021
119
User Guide--Spectra Stack Library
Chapter 4 -- Operating the Library
Opening a Magazine
To unlock a magazine, click Open for the appropriate magazine. The library releases the lock. You can then open the appropriate door and pull the magazine out of the library to access the storage slots.
Notes: Opening a magazine takes the entire library offline.
If you do not open the door and access the magazine within the automatic re-lock duration, the magazine re-locks. See Enabling or Disabling EE Ports on page 64 to change the automatic re-lock duration.
Figure 87 Pull the magazine out of the library. Close the magazine access door after reinserting the magazine.
December 2021
120
User Guide--Spectra Stack Library
Chapter 4 -- Operating the Library
CLEANING A TAPE DRIVE
Cleaning a Tape Drive
You can initiate a drive cleaning operation from the Operation > Clean Drive screen.
Figure 88 The Clean Drive screen.
1. Select a cleaning cartridge from the Source Elements list. The library uses the barcode label to identify cleaning cartridges. If no cleaning cartridges are available, load one into an EE port or magazine slot.
2. Select the tape drive to be cleaned from the Destination Elements list. Tape drives currently containing a cartridge are not listed. To clean a tape drive not listed, move the cartridge out of the drive.
3. Click Submit.
RESCANNING THE CARTRIDGE INVENTORY
To rescan the cartridges in the library, navigate to the Operation > Rescan screen and click Rescan. The library changes to Scanning status and is unavailable to perform other operations until the scan completes.
December 2021
Figure 89 The Rescan Inventory screen.
121
User Guide--Spectra Stack Library
Chapter 4 -- Operating the Library
Forcing a Drive to Eject a Cartridge
FORCING A DRIVE TO EJECT A CARTRIDGE
The force drive media eject operation attempts to force the tape drive to eject the cartridge and place it into an open slot. Only the Administrator user can force eject a tape cartridge.
Before performing this operation, it is recommended that you attempt to eject the tape using your backup software or a library move media operation (see Moving Media on page 117). While a cartridge is being force ejected, a window indicating the process is ongoing displays. No operations are available until the force eject completes.
Note: If the drive has difficulty ejecting the cartridge, the media is possibly bad or damaged. Contact Spectra Logic Technical Support for assistance. See Contacting Spectra Logic on page 7.
Figure 90 The Force Drive Media Eject screen.
1. Navigate to the Operation > Force Drive Media Eject screen. 2. Select the drive for which you want to force a tape ejection in the Source
Elements list. 3. Select the destination in the Destination Elements list. 4. Click Submit.
December 2021
122
User Guide--Spectra Stack Library
CHAPTER 5
Viewing Library Status
This chapter contains instructions for viewing library status. To access the status area, from the Home screen, click Status.
Topic Viewing Library and Module Status Using Inventory Lists
Filtering by Barcode Label Listing Just Drives or Cartridges Viewing Elements by Group Using the Cartridge Inventory Graphical View Using Partition Map Graphical View Using Partition Map Configuration Status Viewing Drive Status Viewing Network Status Viewing Encryption Status
page 124 page 126 page 127 page 127 page 128 page 128 page 130 page 132 page 133 page 136 page 138
123
Chapter 5 -- Viewing Library Status
Viewing Library and Module Status
VIEWING LIBRARY AND MODULE STATUS
Summary information and status is displayed in the top banner and left side bar of the interface. For additional library module configuration and status information navigate to the Status > Library Status screen.
Figure 91 The Library Status screen.
Field
Description
Library Information
Vendor
SPECTRA
Serial Number
Library serial number.
Robotic Hardware Hardware revision of the robotic hardware. Revision
Barcode Reader
Hardware revision of the barcode reader.
Hardware Revision
WWide Node Name A worldwide unique identifier that the library reports over SCSI and can be used by operating systems or software applications to identify and track the library.
Product ID
PYTHON
December 2021
124
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
Viewing Library and Module Status
Field
Description
Library Information (continued)
Firmware Revision Version of the currently installed library firmware.
Robotic Firmware Revision
Version of the currently installed robotic assembly firmware. The robotic assembly firmware is bundled and installed with the library firmware.
Barcode Reader
Version of the currently installed barcode reader firmware. The barcode reader
Firmware Revision firmware is bundled and installed with the library firmware.
Library Status
Library Status
Idle - The library robotic assembly is ready to perform an action. Moving - The library robotic assembly is moving a cartridge. Scanning - The library robotic assembly is performing an inventory of
cartridges. Offline - The library robotic assembly has been taken offline by the library.
Cartridge in Transport
When applicable, displays the barcode label of the cartridge currently in the robotic assembly.
Total Power On Time
Total time that the controller module has been powered on since it was manufactured using the format dd-hh-mm.
Odometer
Robotic assembly move count.
Robotic Location Displays the module where the robotic assembly is currently located.
Shipping Lock
Indicates whether the robotic assembly is unlocked or locked for shipment. For normal library operations the lock should always display as Unlocked.
Module Status
Base Controller
Hardware revision of the controller board currently installed in the module.
Revision or Module
Controller Revision
Left Drive Power Board Status
Status of the drive power board for the top three half-height drive slots in the module.
Right Drive Power Status of the drive power board for the lower three half-height drive slots in the
Board Status
module.
Power Supply Status
Displays the status of power supplies.
Lower/Upper
Displays the status of power supply fans.
Power Supply Fan
Chassis Fan
Displays the status of the chassis fan.
December 2021
125
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
USING INVENTORY LISTS
Using Inventory Lists
The inventory list displays elements, such as slots and tape drives, as well as information about any cartridges currently located in an element.
To view the elements organized by module, use Status > Cartridge Inventory > List View.
To see the elements organized by logical library or partition, use Status > Partition Map > List View.
December 2021
Figure 92 The Cartridge Inventory List View screen.
The Inventory List screen displays the following information:
Field
Description
Module Slot # Label
The module number. Click the arrow to the left of the module number to expand or collapse the inventory display for that module.
The slot number in the form <module>.<slot>, where module is the module number and slot is the slot number in that module. See Element Numbering on page 29.
The barcode label of the tape cartridge present in the element.
126
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
Using Inventory Lists
Field Full Gen Partition
Description
An X displays if a cartridge is present in the element.
The LTO generation of the cartridge.
The partition number to which the element is assigned. To determine the partition name associated with the partition number, see Using Partition Map Configuration Status on page 132.
Clicking a full slot displays the following information about the media in the slot:
Field
Description
Media Loads Encryption
Media Type
The number of media loads.
Indicates whether data on this media is encrypted or not encrypted.
Indicates whether the cartridge is a data or cleaning cartridge.
Filtering by Barcode Label
Use the following instructions to see a subset of the cartridges in the library based on tape barcodes. 1. Click Filter On. The search box displays. 2. Enter characters into the search box and click Search.
Notes: The characters can be anywhere in the barcode label. The search characters are not case sensitive. There are no wildcards.
To disable filtering, click Filter Off.
Listing Just Drives or Cartridges
To limit the list to tape drives, click Drives. The button changes to read Slots. Click Slots to return to viewing all elements.
To limit the list to tape cartridges, click Cartridges. The button changes to read Elements. Click Elements to return to viewing all elements.
December 2021
127
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
Viewing Elements by Group
Using the Cartridge Inventory Graphical View
When the list is grouped, you can expand or contract the list for each group by clicking the triangle next to the number in the first column (Partition or Module). Grouping is enabled by default. To disable grouping, click Group Off. To enable grouping, click Group On.
USING THE CARTRIDGE INVENTORY GRAPHICAL VIEW
The cartridge inventory graphical view displays library elements, such as slots and tape drives, with information about the cartridge stored in the element.
To see the elements organized by module, from Status, navigate to Cartridge Inventory > Graphical View.
To see the elements organized by logical library or partition, see Using Partition Map Graphical View on page 130.
December 2021
Figure 93 The Cartridge Inventory Graphical View screen.
Moving the mouse over a drive or cartridge to display additional information in a pop-up window.
Field
Description
Drive Information
Drive
LTO generation of drive and format (Full Height or Half Height).
Drive #
The drive number. Tape drives are numbered from the bottom of the library up to the top beginning with "1".
Serial #
The serial number assigned to the tape drive by the library.
128
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
Using the Cartridge Inventory Graphical View
Field
Description
Cartridge Information
Barcode
Barcode data on label.
Generation
LTO generation of the cartridge.
Slot #
The slot number in the form <module>.<slot>, where module is the module number and slot is the slot number.
Partition
The partition number to which the cartridge is assigned. To determine the partition name associated with the partition number, see Using Partition Map Configuration Status on page 132.
Media Loads
The number of media loads.
Encryption
Indicates whether data on this media is encrypted or not encrypted.
Media Type
Indicates whether the cartridge is a data or cleaning cartridge.
Warning states and error states for drives and cartridges are indicated with icons. See
Figure 94 The Cartridge Inventory Graphical View warnings.
December 2021
129
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
Using Partition Map Graphical View
USING PARTITION MAP GRAPHICAL VIEW
To see the elements organized by logical library or partition, navigate to Status > Partition Map > Graphical View.
For each module, the graphical view of the partition map, from left to right, displays the left magazine banks from front to back, the drives in the module, and the right magazine banks from back to front. Storage slots display in groups of five. If the EE port in the module is enabled, the right most bank displays single slots with slot numbers preceded by the letters "EE". If an element is configured in a partition, the partition number displays on the element. To determine the partition name associated with the partition number, move the mouse over the partition number.
Figure 95 The Partition Map Graphical View screen.
December 2021
130
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
Using Partition Map Graphical View
Moving the mouse over a partition or drive displays additional information in a pop-up window:
Field
Description
Partition Information
Name Barcode
Media Removal
Key Manager Type Partition S/N
Partition name.
Barcode reporting settings. See Step 3 and Step 4 on page 71 for more information.
Indicates whether media removal is allowed or prevented by the host.
The type of encryption used by the partition.
Serial number of the partition as seen by the host software.
Drive Count Slot Count Media Count EE Port Count Drive Information
Number of drives configured in this partition. Number of slots configured in this partition. Number of cartridges in this partition. Number of EE ports configured in this partition.
Drive #
The drive number. Tape drives are numbered from the bottom of the library up to the top beginning with "1".
Drive
LTO generation of the drive and format (Full Height or Half Height).
Serial #
The serial number assigned to the tape drive by the library.
Partition
The partition number to which the drive is assigned.
If a cartridge is loaded in the drive
Partition
Barcode Generation
The partition number to which this cartridge is configured.
Barcode data on label.
LTO generation of the cartridge.
December 2021
131
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
Using Partition Map Configuration Status
USING PARTITION MAP CONFIGURATION STATUS
To see the configuration of a partition, its elements and their status, from Status, navigate to Partition Map > Configuration Status.
Figure 96 The Partition Map Configuration Status screen.
The Configuration Status screen displays the following information:
Field
Description
Partition Number
Partition Name
Partition S/N
Number of Drives
Number of Slots
Number of EE Ports
Barcode Label Length Rep. to Host
Barcode Label Alignment Rep. to Host
The partition number. The partition name. The partition serial number. Number of drives configured in this partition. Number of slots configured in this partition. Number of EE ports configured in this partition. Barcode length and direction reported to the host. See Step 3 and Step 4 on page 71 for more information. Barcode alignment reported to the host.
Auto Clean
Indicates whether automatic cleaning of drives is enabled or disabled.
December 2021
132
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
Viewing Drive Status
Field Key Manager Type
Active Control Path Drive LTO7+ Multiinitiator SCSI Conflict Detection
Description
The type of encryption (host or KMIP) used by the partition. See Configuring Encryption Key Management on page 77 for more information.
A drive configured in the partition that provides the control path to the library robotics.
Whether the library generates a warning event if it detects more than a single host WWNN accessing a drive. See Step 7 on page 72 for more information.
Listing Just Drives or Partitions
To limit the list to tape drives, click Drives. The button changes to read Partition. Click Partitions to return to viewing all elements.
VIEWING DRIVE STATUS
In the Status > Drive Status screen you can see the configuration and status of each drive installed in the library.
Figure 97 The Drive Status screen.
December 2021
133
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
Viewing Drive Status
In the Drive Status screen you can see:
Field
Description
#
The drive number. Drives are numbered logically from
the bottom of the library up to the top beginning with "1".
S/N
The serial number assigned to the tape drive by the
library. This serial number is reported to host
applications. The serial number cannot be modified.
Note: This is not the serial number assigned to the drive
by the manufacturer; the serial number assigned by the
manufacturer is shown in Manufacturer S/N.
Drive Type Drive Health Icon
The drive type in the form Vendor LTO gen ff int where. Vendor is the manufacturer gen is the generation ff is the form factor (HH: half-height or FH: full-height) int is the interface (FC: Fibre Channel or SAS: Serial
Attached SCSI)
OK - The green check mark icon indicates the drive is fully operational.
Warning - The yellow exclamation point icon indicates that user attention is necessary, but the drive can continue most operations.
Error - The red X icon indicates that the drive experienced an error that prevents it from continuing normal operations, and user intervention is required.
Click the Library Health icon in the top banner for more information about current warnings and errors.
Drive Activity Status
The activity status of the drive. Write--The drive is writing data. Read--The drive is reading data. Idle--A cartridge is present in the drive, but the drive
is not performing any operations. Empty--The drive is empty. Encryp--The drive is writing encrypted data.
Power Status
Indicates whether the drive is currently powered on or off.
Vendor
The manufacturer of the drive.
Firmware
The currently installed drive firmware version.
Powered
Indicates whether the drive is currently powered on or off.
Temperature
The temperature measured by the tape drive in degrees Celsius.
Encryption
Whether encryption is enabled or disabled.
December 2021
134
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
Viewing Drive Status
Field IP Address Module Loc Cooling Fan Status Personality Manufacturer S/N
WWNN Partition
Cartridge Media Removal Data Compression Product ID Port Status - Fibre Channel Drive
Port Status - SAS Drive
Description
The IP address for the drive. If the drive is does not have an Ethernet connection, a status of "N/A" displays.
The module in which the tape drive is located.
Whether the tape drive cooling fan is currently active.
The SCSI Standard Inquiry Data Page which identify the drive vendor.
The serial number assigned to the drive when it was manufactured. Use this serial number when working with your service provider.
The world wide node name assigned to the drive.
The partition number to which the drive is assigned. If the drive provides the active control path for the partition, "(Library LUN)" displays also.
The barcode of the cartridge in the drive, if applicable.
Indicates whether media removal is allowed or prevented by the host.
Whether data compression is enabled or disabled.
ULTRIUM-ff-gen. where ff is the form factor (HH: half- height or FH: full-height) and gen is the generation.
The drive port configuration. WWPN-The world wide port name for the port. Speed -The currently selected Fibre Port speed. The
default is Automatic. Port Type
Automatic Fabric Loop- Enables selection of the Addressing Mode. Interface Loop ID/ALPA - When Addressing Mode is set to Hard, the ALPA address displays.
The drive port configuration. WWPN-The world wide port name for the port. Interface - The connected interface type Speed -The currently configured SAS port speed.
December 2021
135
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
VIEWING NETWORK STATUS
Viewing Network Status
To see the network status, navigate to Status > Network.
Figure 98 The Network Status screen.
In the Network Status screen you can see:
Field
Description
Host Name Domain Name
Protocol
MAC Address
Link Status Link Speed
Library hostname.
The domain name for your network where the library resides.
Whether the library network uses IPv4, IPv6, or both addressing methods.
A unique identifier for the library controller network port.
Enabled or disabled.
Speed of the Ethernet connection to the library.
Duplex
Enabled or disabled.
December 2021
136
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
Viewing Network Status
Field IPv4 Settings DHCP
Address
Netmask
Gateway DNS 1 DNS 2 IPv6 Settings Stateless Addressing
Static Addressing
Description
When Enabled, the library requests an IP address from a DHCP server each time the library is powered on. The IP address in use by the library. If DHCP is enabled, this address was obtained from the DHCP server. If DHCP is disabled, the address was manually configured. The network mask of the library controller used when DHCP is disabled. The gateway used when DHCP is disabled. The first domain name server to access. The second domain name server to access.
When enabled, the library generates an address for itself based on the routing information obtained from a router advertisement and the MAC address. The library can manage up to five global addresses at the same time, which can be assigned from different routers. When enabled, the library uses a statically-configured address.
December 2021
137
User Guide--Spectra Stack Library
Chapter 5 -- Viewing Library Status
VIEWING ENCRYPTION STATUS
Viewing Encryption Status
Navigate to the Status > Security screen to see the status of any key management servers configured for use with the library, as well as the encryption status of the tape drives and partitions.
Figure 99 The Status > Security screen.
The Security Encryption Status pane shows what types of encryption are available in the library, and whether each type is enabled or disabled.
The Partition Encryption Status pane shows what type of encryption is used by each partition and configured Monikers or KMIP servers as applicable. Click Connectivity Check (not shown) to initiate a KMIP server connectivity check.
The Drive Encryption Status pane shows whether a drive is configured to encrypt data using an Encryption Standard key or a key from the KMIP key server configured for the drive's partition.
December 2021
138
User Guide--Spectra Stack Library
CHAPTER 6
Configuring and Using Media Lifecycle Management
This chapter describes how to use BlueVision Media Lifecycle Management to proactively monitor and report on the health of the cartridges in your library.
Topic BlueVision Media Lifecycle Management
Spectra Certified MLM-Enabled Media Media Tracking and Reporting Additional MLM Features MLM Usage Guidelines Using MLM Reporting Generate MLM Reports Save an MLM Report Override a Poor Cartridge Health Report Managing the MLM Database Backup the MLM Database Verify the Database Backup File Restore the MLM Backup File Delete MLM Records From the Database
page 140 page 140 page 140 page 143 page 143 page 143 page 144 page 148 page 149 page 150 page 151 page 151 page 151 page 152
139
Chapter 6 -- Configuring and Using Media Lifecycle Management
Spectra Certified MLM-Enabled Media
BLUEVISION MEDIA LIFECYCLE MANAGEMENT
This section describes the major features of BlueVision Media Lifecycle Management (MLM). The remainder of the chapter provides detailed information about using MLM.
Overview BlueVision Media Lifecycle Management (MLM) helps you manage your tape media (cartridges) by giving you tools to proactively detect potential media errors well before they happen. When used in combination with Spectra Certified MLM-enabled media, MLM lets you manage, track, and report all facets of tape usage from creation to retirement. When used with media that is not MLM-enabled, MLM tracks and reports the general health of the media.
Spectra Certified MLM-Enabled Media
Media Lifecycle Management starts with packaged, barcode labeled, Spectra Certified MLM-enabled media (LTO data cartridges and cleaning cartridges). Before shipment, Spectra Logic writes baseline data to the MAM (Medium Auxiliary Memory) embedded in each cartridge. Throughout its life, the cartridge MAM continually collects data to support MLM tracking and reporting.
Media Tracking and Reporting
Overview MLM uses the information from the cartridge's MAM to maintain a database of vital information about each MLM-enabled cartridge in the library, including the drives into which it was loaded and any errors it encountered. The statistical and diagnostic information in the MLM database helps you proactively manage your tape media throughout its life. Using the information in the database, MLM can generate a variety of reports that let you monitor important health information about every MLM-enabled data cartridge and cleaning cartridge in your library. If desired, you can save the report as s a comma-separated-value (CSV) file to a USB device, email the report, or download to a host computer.
Notes: The MLM database also includes limited information about cartridges that are not MLM-enabled.
The cartridge inventory is separate from the MLM database and only shows cartridges currently stored in the library. The cartridge inventory does not differentiate between MLM-enabled cartridges and those that are not MLM- enabled.
Discovery Requirement Until an MLM-enabled cartridge is discovered when it is loaded into and then unloaded from a drive for the first time, it is not included in the MLM database.
December 2021
140
User Guide--Spectra Stack Library
Chapter 6 -- Configuring and Using Media Lifecycle Management
Media Tracking and Reporting
Media Health Score The initial load/unload during discovery establishes an initial media health score for each cartridge and adds this information to the MLM database. This initial health score may not accurately reflect the actual health of the media. The health score stabilizes and becomes more accurate after the first four loads/unloads as current usage statistics are updated and used in the tape's health scoring.
MLM Health Reports MLM reports let you review important health information about every MLM-enabled data tape and cleaning tape in your library. You can generate comprehensive health reports for the MLM- enabled media in the whole library or in an individual partition. You can also generate more detailed reports with information about compression ratios, load counts, write errors, remaining capacity, encryption status, and more.
The MLM reports help you identify tapes with high error rates or other problems (for example, a dropped leader pin) that pose a risk to protecting your data. These tapes can then be removed before they cause data corruption or other problems. See Generate MLM Reports on page 144 for detailed information about the types of reports you can generate.
MLM Database Management After a cartridge is added to the MLM database, its MLM data remains in the database even if the cartridge is exported from the library. If the cartridge is later reimported, the MLM database is updated to reflect any new information obtained from the cartridge MAM. When a cartridge is permanently removed from service, it can be manually deleted from the database.
The MLM database is restricted to a maximum of 10,000 records. When this limit is reached, the record for the least recently exported cartridge, as determined by the Export Date tracked by MLM, is automatically deleted. The library does not notify you when it reaches the maximum number of records.
To ensure that you have a complete record of all the cartridges that are used in the library, regularly generate and export a Media Health report for the entire library (see Using MLM Reporting on page 143). When a cartridge is retired or permanently exported from the library, its record can be deleted from the MLM database.
If desired, the information in the MLM database can be exported to a comma-separated-value (CSV) file, which can then be imported into Microsoft Excel� or other software applications that support this file type (see Save an MLM Report on page 148).
December 2021
141
User Guide--Spectra Stack Library
Chapter 6 -- Configuring and Using Media Lifecycle Management
Media Tracking and Reporting
Data Cartridge Tracking
A primary function of MLM is to track the health and usage of the data cartridges that are currently in or were previously in the library.
Functional Overview Each time a Spectra Certified MLM-enabled data cartridge is loaded into a drive, MLM records over 30 data points about the cartridge. These data points include health information, the cartridge age, how many times it was loaded and into which drives, and how many errors it accumulated. It also records when the cartridge is exported from the library and by whom. Each MLM-enabled data cartridge has a unique identifier that allows each cartridge to be tracked throughout its life, even if its barcode label is damaged or removed.
December 2021
Cleaning Cartridge Tracking
Functional Overview The library tracks expired cleaning cartridges in the cartridge inventory and does not attempt to use an expired cleaning cartridge. You can identify expired cartridges by examining the Inventory screen.
When you enable MLM and use Spectra Certified MLM-enabled LTO cleaning cartridges, MLM tracks and reports usage information for the cleaning cartridges. This information, which includes the number of cleans remaining and the cartridge health (good, near expiration, or expired), is stored in the MLM database.
Expired MLM-Enabled Cleaning Cartridges Each time an MLM-enabled cleaning cartridge is used in a drive, the drive decrements the number of cleans remaining on the cartridge. When the cartridge is unloaded from the drive, MLM reads the number of cleans remaining from the cartridge MAM. When the number of cleans remaining reaches zero, the library flags the cartridge as expired and does not attempt to use the cartridge again. Because the library does not need to load a cleaning cartridge into a drive to determine that it is expired, cleaning failures due to an expired cartridge are eliminated (assuming the cleaning partition contains a good cleaning cartridge). Information about an expired cleaning cartridge remains in the MLM database even after the cartridge is exported from the library.
Expired Non-MLM Cleaning Cartridges If a cleaning cartridges is not MLM- enabled, the library must load the cleaning cartridge into a drive to determine whether it is expired. When an expired cleaning cartridge is loaded into a drive, it is immediately ejected; the cleaning fails. The library does not attempt to use the expired cartridge for subsequent cleanings.
The library retains the information about an expired cleaning cartridge for as long as it remains in the library or until the library is power-cycled. If an expired non-MLM cartridge is exported and then reimported into the library, the cartridge must be loaded into a drive in order to identify it as expired.
142
User Guide--Spectra Stack Library
Chapter 6 -- Configuring and Using Media Lifecycle Management
Additional MLM Features
Additional MLM Features
In addition to the features described in the previous sections, MLM provides the following features (listed in alphabetical order):
Database Management Management tools let you manually delete tape records from the MLM database when the tape is retired or permanently exported from the library. You can also download the MLM database as a comma-separated-value (CSV) file and open the file in any software application that supports this type of file (for example, spreadsheet software).
Tracking Non-MLM-Enabled Media MLM tracks the basic health information for LTO data cartridges that are not MLM-enabled. This basic health information is based on tape log data retrieved from an MLM- capable LTO drive when the cartridge is ejected. The data pertinent to media health is stored in the MLM database and used to determine the media health status (Usable or Impaired) included in Media Lifecycle Management reports.
MLM Usage Guidelines
Consider the following guidelines when establishing your Media Lifecycle Management policies:
Chose a Retirement Guideline When implementing MLM, decide at the beginning on the criteria to be used when determining when to retire a cartridge.
Regularly Backup Your MLM Database Determine how frequently to export the MLM database for storage. You can save the MLM database to a USB device or email it to a previously configured mail recipient. The database can be loaded back into the library in the event of an error.
Backing up the MLM database produces a point-in-time snapshot of the MLM database. Based on the number of tapes you routinely import into and export from the library, determine how frequently backups are needed to ensure that you can easily restore the MLM database.
USING MLM REPORTING
After the LTO cartridges in your library are added to the MLM database, you are ready to make use of this powerful tool to manage, track, and report all facets of tape usage from creation to retirement.
December 2021
143
User Guide--Spectra Stack Library
Chapter 6 -- Configuring and Using Media Lifecycle Management
Generate MLM Reports
Generate MLM Reports
This report... Media Health
Remaining Capacity
Load Count Write Errors
Use the instructions below to generate an MLM report.
1. Log into the library.
2. From the toolbar menu, select Status > MLM. The MLM Reports screen displays.
3. Select either Total Library or a specific partition from the Partition drop- down list. The screen refreshes to show the selected information.
4. Select the type of report you want from the Report drop-down list.
Notes: Information about MLM-enabled cleaning cartridges only appears in the Exported Media, Media Health, and Born on Date reports.
To view the number of cleans remaining for a cleaning tape, you must save a MLM report as described in Save an MLM Report on page 148 and look for the Cleans Remaining column in the .csv file..
Displays...
The barcode label information, the overall health (media health), and the load count (the number of times the cartridge was loaded into a drive) for each MLM-enabled cartridge in the selected location.
The barcode label information, the overall health (media health), and the load count (the number of times the cartridge was loaded into a drive) for each non-MLM-enabled cartridges in the selected location.
Use the Filter drop-down menu to display media by health rating.
The remaining capacity and maximum capacity for each MLM-enabled data cartridge. The capacity reflects the native capacity of the cartridge, not the compressed capacity. Notes: Until a data cartridge is loaded into, threaded, and then unloaded from a
drive for the first time, its remaining capacity and maximum capacity report as "0". The remaining capacity and maximum capacity for a cartridge are displayed as GB. This report does not include non-MLM-enabled cartridges.
The load count for each MLM-enabled data cartridge in the selected location and the born on date (the date on which Spectra Logic enabled the cartridge to support MLM tracking and reporting). Note: This report does not include non-MLM-enabled cartridges.
The number of soft errors and the load count for each MLM-enabled data cartridge. Note: This report does not include non-MLM-enabled cartridges.
December 2021
144
User Guide--Spectra Stack Library
Chapter 6 -- Configuring and Using Media Lifecycle Management
Generate MLM Reports
This report... Cleans Remaining
Born on Date
Exported Media
Last Write Time / Last Read Time
Displays...
The number of cleanings remaining and the born on date for each MLM enabled cleaning cartridge. Note: This report is not available for non-MLM-enabled cartridges.
The date that the MLM-enabled cartridge (both data and cleaning) was created and certified by Spectra Logic and the load count for each cartridge. Note: This report does not include non-MLM-enabled cartridges.
A list of all the MLM-enabled cartridges (both data and cleaning) that were exported from the library. The report displays the export time and shows the user name of the person who exported the media. Note: This report is not available for non-MLM-enabled cartridges.
Shows the time and date for the most recent write and read operations for each MLM-enabled data cartridge. Note: This report does not include non-MLM-enabled cartridges.
The MLM Reports screen refreshes to display the selected report with a list of the barcode labels for all media in the selected location.
MLM health icons
Figure 100 Use the health icons on the MLM Reports screen to quickly assess media health.
December 2021
145
User Guide--Spectra Stack Library
Chapter 6 -- Configuring and Using Media Lifecycle Management
Generate MLM Reports
The following table describes the meaning of each media health icon. Click a row in the MLM report to view detailed information about that specific piece of media.
Icon Health score Meaning
100 � 80
The media health is Good. Data cartridge: The media is in good condition and operating properly. The
cartridge can be used for writing new data and reading previously written data. Cleaning cartridge: More than 10 cleaning cycles remain on the cartridge.
79 � 50
The media health is Average.
Data cartridge: When the Health graph on the Details screen for the cartridge falls below a health score of 80, the media health icon changes from green to yellow (generally due to normal aging). For maximum reliability, only use the cartridge for restores.
Cleaning cartridge: The cleaning cartridge is near expiration. From one to ten cleaning cycles remain.
49 � 0
The media health is Poor.
Data cartridge: When the Health graph on the Details screen for the cartridge falls below a health score of 50, the media health icon changes to red. The combination of media errors, tape age, and usage indicates that the media reached the end of its useful life for reliable data backups and restores and should be retired.
If you are experiencing an unexpected number of cartridges with poor media health, you may want to investigate further:
Review the media health data for each cartridge to see if it has a high error rate. A high error rate can indicate either that the media health is poor and the cartridge should be retired or that the cartridge was written to by a drive that is having trouble.
If multiple cartridges with high error rates were written to by the same drive, the drive may be the source of the errors. Clean the drive or, if necessary, replace it.
Notes:
If the source of the high error rate is a drive, the media health icon for the affected cartridges should return to either green or yellow after approximately three load/read or write/unload cycles in a known good drive.
If your cartridge has a high error rate that cannot be attributed to a faulty drive, environmental factors, or the end of the cartridge's normal working life, contact Spectra Logic Technical Support for troubleshooting assistance
(see Contacting Spectra Logic on page 7).
Cleaning cartridge: The cleaning cartridge is expired. No more cleaning cycles remain. Replace the cleaning cartridge.
The media health is Unknown. The status of the media cannot be determined.
December 2021
146
User Guide--Spectra Stack Library
Chapter 6 -- Configuring and Using Media Lifecycle Management
Generate MLM Reports
5. If you want to view detailed information about a specific cartridge, use one of the following methods to locate the cartridge.
To find a cartridge using the... Cartridge list
Barcode label information
Follow these steps...
Scroll through the list of cartridges on the MLM Reports screen to locate the desired cartridge. 1. Enter the barcode label information for the cartridge you want to locate in the
Find by Barcode field. 2. Click Search. The list of cartridges refreshes to show the requested cartridge.
6. Click a row in the MLM report to view detailed information about that specific piece of media. The Details screen for the selected cartridge displays.
Note: Media health is based on the MLM-tracked history of the cartridge. The health indicated by the Health graph on the Details screen may fluctuate until the cartridge is loaded six times.
Health graph
December 2021
Figure 101 The detailed MLM report for the selected media.
When using CarbideCleanTM media, the Details screen includes additional information related to the CarbideClean process. This information is not present for MLM media that was not put through the CarbideClean process. 7. Click OK to return to the main MLM Reports screen (Figure 100 on page 145).
147
User Guide--Spectra Stack Library
Chapter 6 -- Configuring and Using Media Lifecycle Management
Save an MLM Report
Save an MLM Report
You can choose to save a copy of the MLM report, which is a comma- separated text file (*.csv), to a USB device, email the report, or save the report to your host computer.
1. If you want to save a specific report, generate the desired report as described in Generate MLM Reports on page 144. Otherwise, continue with Step 2 to save all MLM data.
2. If you want to save the MLM report to a USB device, connect the device to a USB port on the LCM or operator panel and allow time for the device to mount before continuing.
3. Click Save to display the Save MLM Report screen.
This option... Report All Media Lifecycle Data
Report Selected Data
Figure 102 Select the desired options on the Save MLM Report screen.
4. Select the data to include in the saved report.
Saves...
A report containing all of the available detailed MLM data for MLM-enabled media in the total library. Note: Depending on the number of cartridges in the selected location, this report can be quite large.
Only the fields displayed in the report that you selected on the MLM Reports screen (Figure 100 on page 145). Note: The headings in the saved report reflect the fields displayed in the report you selected in the MLM Reports screen.
December 2021
148
User Guide--Spectra Stack Library
Chapter 6 -- Configuring and Using Media Lifecycle Management Override a Poor Cartridge Health Report
Selection RMI download Mail Report to USB key
5. Select how you want the report saved
Destination Download the report to your host computer. Enter an email address to which the report is sent. Save the report to the USB device.
6. Click Submit to send the report to the selected destination. Click Close to return to the MLM Reports screen without sending the report.
Override a Poor Cartridge Health Report
Under certain circumstances you may need to override the health of an MLM-enabled cartridge that is reported as poor (a red health icon appears next to the cartridge barcode). When the cartridge health is poor, a green arrow appears that can be used to override the reported health.
During the override process, the library progressively eliminates any recent hard errors from the tape health calculation until the cartridge health returns to either Good or Average.
Important Do not reset the cartridge health unless you believe that the reported poor health
is due to drive problems and not the cartridge or you are specifically directed to do so by Spectra Logic Technical Support.
Use the following steps to reset the health of a single cartridge. 1. Display the Media Health report as described in Generate MLM
Reports on page 144. 2. Locate the barcode of the cartridge for which you need to reset the
health (see Step 6 on page 147).
December 2021
149
User Guide--Spectra Stack Library
Chapter 6 -- Configuring and Using Media Lifecycle Management Override a Poor Cartridge Health Report
3. Click the green arrow button for the cartridge. The library adjusts parameters used to calculate the tape health until the reported health is Average.
Override MLM health
Figure 103 Click the green override button to reset the reported health for an MLM-enabled LTO cartridge.
4. Attempt to resolve the issues that were causing the media health to be reported as poor.
MANAGING THE MLM DATABASE
The MLM database contains the usage history, health, and the verification data for all of the MLM-enabled cartridges in your library. Deciding when and how often you back up the MLM database depends on many factors, including how often tapes are loaded into a drive. If all of the tapes are loaded into drives frequently, the MLM database
can be rebuilt relatively quickly. The database can be backed up less frequently. If many of the tapes remain in the library without being loaded into a drive for a long period of time, or if tapes are exported and stay outside of the library for a long period of time, rebuilding the MLM database can take a long time. Back up the MLM database more frequently.
December 2021
150
User Guide--Spectra Stack Library
Chapter 6 -- Configuring and Using Media Lifecycle Management
Backup the MLM Database
Backup the MLM Database
Based on your environment, determine how frequently backups are needed, then use the following steps to create a backup. You must use the RMI to backup the MLM database.
1. Use your storage management software to stop all backup or restore operations on the library.
2. Log into the library as a user with administrator privileges.
3. From the toolbar menu, select Configuration > System > Save/Restore Configuration.
4. Click Save MLM Database to expand the section.
5. Click Save The Save MLM Database dialog box displays.
6. Click Download. The database backup file saves to your local computer.
Verify the Database Backup File
After backing up the MLM database, use the instructions below to confirm that the backup file was generated correctly. 1. Open the ZIP archive file downloaded in Backup the MLM Database. 2. Confirm the .ENC file is greater than 0 kilobytes. 3. Confirm the SQLTE file is greater than 0 kilobytes.
Restore the MLM Backup File
If you need to reset your library to factory defaults, it is helpful to restore the MLM database so you do not have to manually rediscover MLM cartridge information. You must use the RMI to restore an MLM database.
Use the instructions below to restore a previously saved MLM database to your Stack library.
1. Log into the library as a user with administrator privileges.
2. From the toolbar menu, select Configuration > System > Save/Restore Configuration.
3. Click Restore MLM Database to expand the section.
4. Click Choose File and browse to the location where the MLM database backup file is stored.
5. Click Upload File & Restore. The library restores the MLM database.
December 2021
151
User Guide--Spectra Stack Library
Chapter 6 -- Configuring and Using Media Lifecycle Management Delete MLM Records From the Database
Delete MLM Records From the Database
If desired, you can delete the MLM record of a tape at any time. This is useful when a tape is retired or permanently exported from the library. If you delete the record of a tape that remains in the library, the MLM record is re-populated the next time the tape is loaded into a drive.
Note: MLM records for a tape can only be deleted after the tape is exported from the library.
1. Log into the library as a user with administrator privileges. 2. Display a Media Lifecycle Report as described in Generate MLM
Reports on page 144. 3. Locate the barcode of the cartridge you want to remove from the MLM
database (see Step 6 on page 147). 4. Click the trash can icon next to the barcode to delete the record.
Click the trash can icon to delete the selected cartridge from the MLM database.
Figure 104 Use the trash can icon to delete individual records from the MLM database. 5. Respond to the confirmation message to delete the record.
December 2021
152
User Guide--Spectra Stack Library
CHAPTER 7
Maintaining the Library
This chapter contains instructions for maintaining the library. From the Home screen click Maintenance to access the library maintenance features.
Topic Library Tests
System Test Slot to Slot Test Element to Element Test Position Test Wellness Test Robotics Test OCP Test and Calibration Logs and Traces Viewing Log Files Downloading Log and Trace Files Software Upgrades Software Upgrades Managing Drive Firmware Downloading Drive Logs Rebooting the Library Rebooting Drives Controlling the UID LED Moving the Robotic Assembly to the Controller Module
page 154 page 154 page 154 page 155 page 157 page 157 page 158 page 159 page 159 page 159 page 160 page 161 page 161 page 163 page 165 page 165 page 166 page 167 page 167
153
Chapter 7 -- Maintaining the Library
LIBRARY TESTS
Library Tests
System Test
The system test exercises overall library functionality by moving cartridges within the library. During each cycle, the library moves a cartridge from a full slot to an
empty slot and then returns it to its original slot. You can select the number of cycles for the test. If the test is cancelled, the library returns the cartridge to its original slot. The library does not move cleaning cartridges during the test. The test operates over the whole library and does not take into account partition configuration. During the test the library is offline.
To run the system test, navigate to the Maintenance > Library Tests > System Test screen, select the number of cycles, and then click Start Test.
Figure 105 The System Test screen.
Slot to Slot Test
The slot to slot test randomly exchanges cartridges between slots to verify that the library is operating correctly. At the end of the test, the cartridges are not returned to their original slots. If a tape is moved to an incompatible drive, the drive rejects the tape, as designed.
Caution The test can move cartridges between partitions.
For service and diagnostics, use the Robotics Test on page 158.
December 2021
154
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
Library Tests
To run the slot to slot test, navigate to the Maintenance > Library Tests > Slot to Slot Test screen, select the number of cycles, and click Start Test.
Figure 106 The Slot to Slot Test screen.
Element to Element Test
The element to element test moves a selected cartridge to a selected slot or tape drive, and then returns it to the original slot. If the selected destination is a tape drive, the tape is loaded and unloaded before it is returned. You can select the number of times to move the selected cartridge to the destination location and back. The element to element test is intended to show that the library is operating correctly. To diagnose problems with the robotic assembly or verify that it has been correctly replaced, use the Robotics Test on page 158.
December 2021
155
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
Library Tests
To run the element test:
1. Navigate to the Maintenance > Library Tests > Element to Element Test screen.
Figure 107 The Slot to Slot Test screen.
2. Select a cartridge from the Source Elements list. To view a subset of the cartridges by barcode: a. Click Filter On. b. Enter characters into the search box and then click Search. The Source Elements list is updated to only include cartridges with barcode labels including the search characters.
3. Select a location from the Destination Elements list. 4. Using the drop-down menu, select the number of Cycles. 5. Click Start Test.
December 2021
156
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
Position Test
Library Tests
The Position Test moves the robotic assembly vertically between two selected elements. The test does not move cartridges.
1. To run the position test, navigate to the Maintenance > Library Tests > Position Test screen.
Figure 108 The Position Test screen.
2. Select one element from the Source Element list and another from the Destination Element list.
3. Using the drop-down menu, select the number of Cycles, and click Start Test.
Wellness Test
The wellness test performs a general health check on the library functionality by running the following tests:
Basic Hardware Review Robotics Initialization Test Barcode Scanning Test Magazine/EE Port Unlock Motor Test Move Media Test
December 2021
157
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
Library Tests
Keep the following in mind when running the Wellness test:
Running the test requires at least one drive and one tape cartridge in the library.
After the test has started, the Stop Test button is active. Clicking Stop Test aborts the wellness test, but not before the current test has completed.
The test operates over the entire library and does not take into account partition configuration.
During the test the library is offline.
The Info column notifies the user of the status and result of each test.
To run the system test, navigate to the Maintenance > Library Tests > Wellness Test screen, and then click Start Test.
Figure 109 The Wellness Test screen.
Robotics Test
The robotics test performs a full inventory and exercises all robotic assembly movements and sensors. To run the robotics test, navigate to the Maintenance > Library Tests > Robotic Test screen, then click Start Test.
December 2021
Figure 110 The Robotic Test screen.
158
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
OCP Test and Calibration
Logs and Traces
1. To test or calibrate the OCP, navigate to the Maintenance > Library Tests > OCP Test screen.
Figure 111 The OCP Test screen.
2. Select the desired test: LED test - illuminates each of the front panel LEDs Touch panel calibration test - allows you to calibrate the LCD touch screen OCP reboot - reboots the LCD touch screen
3. Click Start. 4. Follow the instructions on the screen.
LOGS AND TRACES
Viewing Log Files
To view the library log files, navigate to the Maintenance > Logs and Traces > View Logs screen and then select one of the logs. The available logs are: Event Ticket Log - Records library error and warning events Information Log - Records library information warnings Configuration Log - Records configuration changes
December 2021
Figure 112 The View Logs screen.
159
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
Logs and Traces
The log entries are displayed in order of most recent to oldest. The log entries contain a date and time code, event code, severity, component identifier, and event details. The format for the date and time is: YY.MM.DD HH.MM.SS.ss.
YY.MM.DD - The date displayed as Year.Month.Day HH.MM.SS.ss - The time displayed as
Hour.Minute.Second.Hundredths of a second
Downloading Log and Trace Files
To download the library log and trace files from the RMI, navigate to the Maintenance > Logs and Traces > Download Logs and Traces screen and click Save.
Figure 113 The Download Logs and Traces screen.
December 2021
160
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
SOFTWARE UPGRADES
Software Upgrades
Managing System Firmware
Check the Library Firmware Version
The firmware version currently installed on the library is displayed in the library status area on the Home page.
Figure 114 Spectra Stack Main screen.
Check and Download the Currently Released BlueVision Version
Follow these steps to check the currently recommended BlueVision version: 1. Log into your user account on the Technical Support portal at
support.spectralogic.com. Note: See Accessing the Technical Support Portal on page 203 for
information about creating an account and accessing the Technical Support portal. 2. Select Downloads > Product Software.
December 2021
161
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
Software Upgrades
3. On the Product Software page, locate your library type in the Spectra Product column. The currently released BlueVision version is listed in the Current Version column.
Figure 115 The Product Software screen (T950 library firmware shown).
4. Compare the Current Version available for the library to the version installed on the library.
5. If there is a new version of the library firmware, click the name of the BlueVision package. The package begins downloading through your web browser.
Upload Library Firmware
You upload the library firmware from the Maintenance > Software Upgrades > System Firmware screen.
December 2021
Figure 116 The System Firmware screen.
To update library firmware from the RMI: 1. Use your web browser to select the firmware file from the local
computer. 2. Click Start Upgrade. The update process starts immediately and cannot
be canceled. To update the library firmware from the OCP: 1. Copy the firmware file to a USB device. 2. Insert the USB device into the USB port on the front of the library.
The library detects the USB device. 3. Select the firmware file. 4. Click Start Upgrade. The update process starts immediately and cannot
be canceled.
When you update the library firmware, the library updates the firmware of the expansion modules to a compatible version.
162
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
Managing Drive Firmware
Software Upgrades
Drive firmware can be updated on multiple drives of the same type at the same time. Drive firmware can only be updated from the RMI. Each drive will only accept appropriate firmware.
Check the Drive Firmware Version
To see the firmware version currently installed on the drives, navigate to the Status > Drive Status screen.
Figure 117 The Drive Status screen.
Check and Download the Currently Released Drive Firmware
Download the recommended drive firmware from the Spectra Logic Technical Support portal, and save it to your local computer. 1. Log into your user account on the Technical Support portal at
support.spectralogic.com. Note: See Accessing the Technical Support Portal on page 203 for
information about creating an account and accessing the Technical Support portal. 2. Select Downloads > Drive Firmware.
December 2021
163
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
Software Upgrades
3. On the Tape Drive Firmware page, locate the appropriate drive firmware with respect to drive type (LTO), generation (for example, LTO-6), interface type (for example, SAS or Fibre), and form factor (full-height or half-height).
Figure 118 A portion of the Tape Drive Firmware page.
4. Click the firmware version name in the column labeled Current FW File. Note: While the column header references that the file is for "use with ITDT", the file is also compatible with your Spectra Stack library.
5. Use your web browser's download features to save the file
Update Drive Firmware
1. Navigate to the Maintenance > Software Upgrades > Drive Firmware screen. The tape drives are organized by drive type.
December 2021
Figure 119 The Drive Firmware screen.
2. Expand the appropriate drive type and select one or more tape drives. 3. Click Browse and use your web browser to select the firmware file. 4. Click Submit.
164
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
DOWNLOADING DRIVE LOGS
Downloading Drive Logs
To download a drive log from the RMI: 1. Navigate to the Maintenance > Download Drive Logs screen.
Figure 120 The Download Drive Logs screen. 2. Select the drive(s) from which you want to collect logs. 3. Select the type of log to collect (Regular Dump or Forced Dump). 4. Click Save.
REBOOTING THE LIBRARY
From the Maintenance > System Reboot screen, click Reboot.
Figure 121 The System Reboot screen.
December 2021
165
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
REBOOTING DRIVES
Rebooting Drives
1. From the Maintenance > Drive Reboot screen, select the drive(s) you want to reboot and click Submit.
Figure 122 The Drive Reboot screen. 2. Click Yes on the dialog popup to start the reboot process.
December 2021
166
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
CONTROLLING THE UID LED
Controlling the UID LED
The UID LEDs are a pair of blue LEDs - one on the OCP and the other on the controller module controller. The UID LEDs are useful for identifying the library in a data center. The UID LEDs are operated synchronously and controlled by the user. You can see if the LEDs are lit, and toggle the status from the Maintenance > UID LED Control screen.
Figure 123 The Maintenance > UID LED Control screen.
MOVING THE ROBOTIC ASSEMBLY TO THE CONTROLLER MODULE
Before extending a module from the rack, the robotic assembly must return to its park position in the controller module. Under normal circumstances, when the library is powered off using the front power button, the robot automatically parks and locks into the controller module behind the OCP. After powering off the library and before proceeding with extending a module from the rack, look inside the controller module window to verify that the robotic assembly is behind the OCP. Use the following instruction if the library did not move the robotic assembly to its park position: 1. Power on the library. 2. Log into the library as an Administrator user.
December 2021
167
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
LTO-9 New Media Initialization
3. Navigate to the Maintenance > Move Robotic to Base Library screen.
Figure 124 The Move Robotic to Base Module screen.
4. Click Submit. If the robot still did not park and locks into the controller module, contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
LTO-9 NEW MEDIA INITIALIZATION
The LTO-9 cartridge initialization includes a media calibration process that increases the initialization time to up to two hours per cartridge. To assist with this, you can use this wizard to start a bulk initialization of LTO-9 cartridges in the tape library.
Important
After the LTO-9 New Media Initialization starts, it is possible to abort the process; however, any media that has been loaded into a drive MUST complete its initialization before the wizard aborts and the processing of remaining media stops. Shutting down the initialization process can take up to two hours.
Important All Spectra Certified LTO-9 media is initialized before it ships and does not need to
go through this process.
Use the instructions below to initialize LTO-9 media using the LTO-9 New Media Initialization Wizard.
1. Navigate to the Maintenance > LTO-9 New Media Initialization Wizard screen. The LTO-9 New Media Initialization Wizard screen displays.
December 2021
Figure 125 The LTO-9 New Media Initialization Wizard screen.
168
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
LTO-9 New Media Initialization
2. Click Start LTO-9 New Media Initialization Wizard. The Information screen displays.
Figure 126 The Information screen.
3. Read the note for the wizard and click Next. The Select Cartridges screen displays.
Figure 127 The Select Cartridges screen.
December 2021
169
User Guide--Spectra Stack Library
Chapter 7 -- Maintaining the Library
LTO-9 New Media Initialization
4. Select the LTO-9 cartridges that you want to initialize and click >> to move them to the Selected Cartridges column. When all of the cartridges that you want initialized are in the Selected Cartridges column, click Next. The Select Drives screen displays.
Figure 128 The Select Drives screen.
5. Select the LTO-9 drives that you want to use to initialize the cartridges and click >> to move them to the Selected Drives column. To maximize efficiency, select as many LTO-9 drives as possible. When all of the drives that you want to use to initialize cartridges are in the Selected Drives column, click Next. The Finish screen displays.
December 2021
Figure 129 The Finish screen.
6. Click Finish. The initialization process begins. 7. If necessary, click Abort Media Initialization to stop initializing
cartridges before all cartridges are initialized; however, any media that has been loaded into a drive MUST complete its initialization before the initialization aborts and the processing of remaining media stops. Shutting down the wizard process can take up to two hours.
170
User Guide--Spectra Stack Library
CHAPTER 8
Library Troubleshooting
Caution
This library is designed to operate when installed in a rack using the rack rail kit. Operating the library without installing it in the rails, such as on a table or rack shelf, may
result in library errors. Placing any weight on top of the library might also cause errors.
Topic Fibre Channel Connection Problems Detection Problems after Installing a SAS Drive Operation Problems
Power Problems Failure/Attention Indications Displayed on the Operator Control Panel Tape Movement Problems Media Problems Attention LED is Lit Inventory Problems RMI Network Connection Issues Cleaning Problems Performance Problems Average File Size File Storage System Connection from the Backup/Archive Host Server to a Disk Array Backup/Archive Server Backup/Archive Software and Method Connection from the Archive/Backup Host Server to the Library Media Finding Event Information Unlocking the Magazine Using the OCP or RMI Using the Manual Release Unloading a Stuck Tape Identifying a Failed Component
page 172 page 173 page 175 page 175 page 175
page 176 page 176 page 177 page 178 page 178 page 179 page 179 page 179 page 180 page 180
page 180 page 181 page 180
page 181 page 182 page 182 page 182 page 183 page 183 page 184
171
Chapter 8 -- Library Troubleshooting
Fibre Channel Connection Problems
FIBRE CHANNEL CONNECTION PROBLEMS
Use the Status> Drive Status screen to check the link connection for your tape drive.
If the screen shows Logged Out:
Check that the Fibre speed is set to Automatic or that the correct Fibre speed is selected. If you are unsure of the speed of the HBA or switch that the drive is connected to, select Automatic.
Check that the correct port type, fabric or loop, is selected. Loop requires additional configuration. If you are unsure of the correct port type, select Automatic.
If the screen shows No Link, the Speed Status displays the `-' character, and the Link LED on the back of the drive is off:
The speed is probably set incorrectly. Try setting the speed to Automatic.
If there are still issues, change the port type to Auto Detect.
If the screen shows No Light:
The cable is not plugged in correctly. Check that it is connected correctly to Port A of the tape drive.
The cable is damaged. FC cables are delicate. If the cable has been bent or twisted sharply, it might be broken and must be replaced.
If the screen shows ALPA Conflict:
There might be a conflict with the ALPA address on Loop ports. Select Soft for the Loop mode to allow the system to select an available address each time the tape drive connects to the FC fabric. If your server configuration does not support changing addresses, try using the Hard Auto-Select option for the Loop mode. This allows the system to select an available address when it first connects, and then retain that address for future connections.
December 2021
172
User Guide--Spectra Stack Library
Chapter 8 -- Library Troubleshooting
Detection Problems after Installing a SAS Drive
DETECTION PROBLEMS AFTER INSTALLING A SAS DRIVE
Problems encountered after installation are often caused by improper SAS cable connections, storage management software configuration errors, or operating system configuration errors. If the storage management software or operating system does not communicate with the library after installation, determine the extent of the detection problem:
Does the storage management software detect the tape drive?
Does the storage management software detect the library?
Does the operating system detect the tape drive?
Does the operating system detect the library?
Does the operating system detect the library, but list it as a generic device?
Based on the extent of the detection problem, check the following:
If neither the storage management software nor operating system detects the tape drive, or they do not detect both the tape drive and the library:
Verify that all SAS cables are securely connected at both ends.
Check the length and integrity of your SAS cabling. For reliable operation, do not use a SAS cable longer than six meters. Do not use a cable adapter or converters between the HBA and the library.
Check the SAS connectors for damage or debris.
Verify that your HBA is supported by the host computer and qualified with the library.
Verify that your HBA has the latest firmware.
If the storage management software or operating system detects the tape drive, but not the library:
Verify that multiple LUN support is enabled on the HBA. The library uses two Logical Unit Numbers (LUNs) to control the tape drive (LUN 0) and robotic assembly (LUN 1). The library requires an HBA with multiple LUN support and multiple LUN support must be enabled on the host computer. When multiple LUN support is disabled, the host computer can see the tape drive, but not the library.
Note: Many RAID or array controllers do not provide multiple LUN support.
December 2021
173
User Guide--Spectra Stack Library
Chapter 8 -- Library Troubleshooting
Detection Problems after Installing a SAS Drive
If the storage management software or operating system does not detect any devices on the HBA:
Verify that the SAS host adapter is installed correctly. Refer to the manual that came with your host adapter for installation and troubleshooting instructions.
Verify that the proper device driver is installed for the SAS host adapter.
If the library is detected by the operating system, but not by the storage management software:
Refer to the documentation included with your storage management application for instructions on how to verify proper installation. Some backup software packages require an additional driver to communicate with the robotics.
If the library is detected by the operating system, but is listed as an unknown or generic device:
Make sure that the proper device driver, if applicable, is installed for the library. Check your storage management software providers website for the latest drivers and patches.
If you continue to have problems with a SAS library, check the following:
Ensure that the library is compatible with the SAS host adapter and storage management software you plan to use.
Verify that your HBA is supported by the host computer and qualified with the library.
Ensure you are using a compatible, high-quality cable.
December 2021
174
User Guide--Spectra Stack Library
Chapter 8 -- Library Troubleshooting
OPERATION PROBLEMS
Power Problems
Operation Problems
Problem
Solution
Library does not power on
1. Check all power cord connections. 2. Check the LEDs on the power supplies. 3. Make sure the power button on the front panel has been pressed, and the
green Ready LED is lit. 4. Make sure the outlet has power. Try another working outlet. 5. Replace the power cord.
No message appears on the OCP display
1. Check all power cord connections. 2. Check the LEDs on the power supplies. 3. Make sure the power button on the front panel has been pressed, and the
green Ready LED is lit. 4. Make sure the outlet has power. Try another working outlet.
Failure/Attention Indications Displayed on the Operator Control Panel
If the problem persists, contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
Problem
The OCP displays a warning or error icon
The OCP displays an error code
Solution Click the icon to see more information about the event on the OCP.
Look up the error code, try to resolve the failure, and power cycle the library (see Event Codes on page 185).
December 2021
175
User Guide--Spectra Stack Library
Chapter 8 -- Library Troubleshooting
Tape Movement Problems
Operation Problems
Problem Tape stuck in drive
Tape cannot be removed from storage slot
Solution
Try the following steps, in this order, to remove the stuck tape. Note: The tape drive must rewind the tape before ejecting it. This can take as long as five minutes, depending on how much tape must be rewound. Once the tape is rewound, the eject cycle takes approximately 15 seconds.
The Ready light flashes while the tape rewinds. Wait for the tape to finish rewinding before attempting another operation. 1. Attempt to unload the tape from your backup software. 2. Shut down the storage management software and stop the operating
systems removable storage services. From the Operation > Move Media screen, attempt to unload or move the tape to a slot. 3. Power down the library and disconnect the cable from the drive. Power up the library, and wait until the tape drive is idle or ready. From the Operation > Move Media screen, attempt to unload or move the tape to a slot. 4. From the Operation > Force Drive Media Eject screen, attempt to force eject the tape .
Important: Inspect the tape cartridge. Damage or misplaced labels on the cartridge may have caused the load/unload failure. Discard any tape cartridge found to have issues.
1. Unlock the magazine from the Operation > Open Magazine screen and extend it to access the storage slot.
2. Grasp the cartridge and remove it from the storage slot. Some tapes need to be inserted and removed several times to condition them for free movement in and out of the magazine.
3. Check the barcode label and verity that it is secure to the cartridge. 4. Check the cartridge for damage. 5. Check the storage slot for damage.
Media Problems
Problem
Cleaning or data cartridge incompatible with drive
Solution
Check the event log to see which cartridge is incompatible. Make sure you are using data and cleaning cartridges that are compatible
with the drive and that you are using the correct cartridge type for the operation. The drive automatically unloads incompatible cartridges, the Attention LED flashes. Export the media.
December 2021
176
User Guide--Spectra Stack Library
Chapter 8 -- Library Troubleshooting
Operation Problems
Problem
Cannot write to or read from tape
Solution
Make sure that the cartridge is not a WORM cartridge that has already been used.
Make sure that the cartridge is write enabled (move the write-protect switch to the enabled position).
Make sure the data cartridge is compatible with the drive model. LTO-5 through LTO-7 tape drives can read data cartridges from two generations back and write to data cartridges one generation back. LTO-8 drives can read and write LTO-7 and LTO-8 tapes only.
Make sure that the cartridge has not been exposed to harsh environmental, magnetic, or electrical conditions and is not physically damaged in any way.
Many storage management applications do not read or write to cartridges that were created using a different application. In this case, you may have to perform an erase, format, or label operation on the cartridge.
Make sure you understand any data protection or overwrite protection schemes that your storage management application may be using, which could prevent you from writing to a given cartridge.
Retry the operation with a different, known good tape. Clean the tape drive from the Operation > Clean Drive screen.
Attention LED is Lit
Problem
Both the Attention and Cleaning LEDs are lit
A particular cartridge sets off the cleaning light
A cartridge recently imported from a different environment is causing issues
The Attention LED is lit but the Cleaning LED is not lit after a cartridge load
Solution
This is most likely caused by a dirty drive that cannot read a tape and marks the tape invalid. Log into the OCP or RMI and check the event log to see which drive has reported that it needs cleaning. Clean the drive with an approved Ultrium cleaning cartridge.
Remove the cartridge from the library.
Media that is moved from one environment to another can cause issues until it has acclimated to the new conditions. A cartridge should be acclimated for at least 24 hours before use, particularly if it has been stored at a substantially different temperature or level of humidity than the library.
The library was unable to complete the requested operation with the selected tape cartridge. Use only cartridges that are compatible with the drive type Use the correct type of cartridges for the operation. For example, use a
cleaning cartridge for cleaning. Make sure you are using a Universal cleaning cartridge
December 2021
177
User Guide--Spectra Stack Library
Chapter 8 -- Library Troubleshooting
Operation Problems
Problem
Solution
The Cleaning LED is The cleaning cartridge has expired. A cleaning cartridge expires after 50 uses. lit after using a
cleaning cartridge
A particular cartridge sets off the Attention LED and possibly the Cleaning LED
Retry the operation with a different cleaning cartridge.
If the Attention LED is cleared and the drive has been cleaned, and then immediately re-displays each time a particular cartridge is reloaded, that cartridge should be suspected as being defective. If this occurs, export the cartridge and load a known good cartridge. Any cartridge that is suspected of being defective or contaminated should
NOT be reused in any drive. If the bad cartridge is a cleaning cartridge, it might be expired.
Inventory Problems
Problem
The library displays incorrect barcodes
Solution
Verify that the label is properly applied. Verify that the label is not soiled.
RMI Network Connection Issues
Problem
Cannot connect to the RMI
Solution
Verify that the Ethernet cable is connected to the controller modules controller board and to the LAN.
Verify that the link LED on the RJ45 (LAN) connector is lit when the library is powered on. If the LED is not lit, the library is not communicating with the LAN. See your network administrator for help.
Verify that the library has been configured with a valid static network address or DHCP has been enabled so the library can obtain a network address. If using DHCP, obtain the librarys network address from the OCP login screen. If the library did not obtain a valid address via DHCP, verify that the DHCP server is up and the library has network access to it. If necessary, set a static network address instead.
Enter the librarys IP address into the address bar of a web browser connected to the same LAN as the library. If the RMI web page does not display, ping the librarys IP address. If the ping fails, verify that the library has a valid network address and that there are no firewalls or other obstructions to network traffic between the computer with the web browser and the library. See your network administrator for help.
December 2021
178
User Guide--Spectra Stack Library
Chapter 8 -- Library Troubleshooting
Cleaning Problems
Performance Problems
Problem
Cannot load the cleaning cartridge
Solution
Make sure you are using an Ultrium cleaning cartridge. Make sure the cleaning cartridge has not expired. A cleaning cartridge
expires after 50 cleaning cycles. Power cycle the library.
PERFORMANCE PROBLEMS
The storage management process involves many system components, from the files in the file system on the host computer, through the backup server, and out to the library, all managed by software running on an operating system. The storage management process only runs as fast as the slowest component in the system.
Performance issues are solved by identifying and addressing performance limitations in your system. See sections below for the following potential performance limitations: Average File Size on page 179 File Storage System on page 180 Connection from the Backup/Archive Host Server to a Disk Array on
page 180 Backup/Archive Server on page 180 Backup/Archive Software and Method on page 181 Connection from the Backup/Archive Host Server to a Disk Array on
page 180 Media on page 181
Average File Size
The hard drive must seek to the position of a file before it can start reading. The more time the disk drive spends seeking to files, the lower the performance. Therefore, if the average file size is small, the read performance is lower.
To determine the average file size, divide the size of the backup by the number of files.
December 2021
179
User Guide--Spectra Stack Library
Chapter 8 -- Library Troubleshooting
Performance Problems
If the average file size is small (64 KB or less), consider using a sequential, image, or block backup method that backs up the whole hard drive or LUN image instead of individual files. The trade off for using one of these methods is that you might only be able to restore the entire image instead of individual files.
Note: File fragmentation also causes excessive drive seeking, which lowers performance, so ensure that files are regularly defragmented.
File Storage System
The file storage system determines the organization of the files on the disks. Using RAID controllers to spread files over multiple disks can improve performance because some disks can be seeking while others are reading. Storing files on a single non-RAID disk results in the slowest performance while storing files on a high-end disk array results in the fastest performance.
Converting standalone disks to RAID can improve performance.
Connection from the Backup/Archive Host Server to a Disk Array
The network connection between the host server and the disk array determines how much data can be transferred from the disks to the host computer at a time. A connection with insufficient bandwidth cannot provide enough data for the tape drives to write at full speed. For optimum performance, the storage subsystem must be able to provide data at the tape drives maximum transfer rate. Backup systems using a lower speed Ethernet network should use multiple network connections.
Backup/Archive Server
The backup server must have enough RAM and processor power to transfer the files from the disk to the tape drive, in addition to running the backup or archive software, and any other processes.
Check the RAM and processor usage during a backup operation. If they are operating at capacity, adding RAM or processor capability can improve performance.
December 2021
180
User Guide--Spectra Stack Library
Chapter 8 -- Library Troubleshooting
Backup/Archive Software and Method
Performance Problems
Each backup method has its own impact on performance, depending on how well it can keep data streaming to a tape drive. In most cases, native applications dont have the features required to maximize performance for LTO tape drives. It is recommended to use a full-featured backup or archive application with this library.
File-by-file backup or archive methods provide the best restore performance if you only need to restore individual files. However, if the average file size is small, file-by-file methods significantly reduce performance.
Disk image, flash, or sequential backup methods provide the fastest performance because they back up an entire disk, partition, or LUN, which minimizes disk seeking. The disadvantage is that backup and restore operations work on an entire disk, partition, or LUN. You might not be able to back up a subset of files or restore a single file. If you can restore a single file, the restore process is slow.
Database backup performance varies based on the use model. To improve performance when backing up data from a database:
Use specific backup agents for the database. Use the latest versions of the databases. Do not back up individual mailboxes. Do not back up specific records or do a record-by-record backup. Do not back up when the database is in heavy use.
Connection from the Archive/Backup Host Server to the Library
For the best performance, the connection from the host server to the library must have enough bandwidth to provide enough data to keep the tape drive streaming. Current LTO tape drives take advantage of some of the fastest interfaces available so the type of interface used to connect the library to the host server is not likely to be the cause of a performance issue. However, issues with cables and connectors can limit performance.
Note: Do not exceed recommended cable lengths.
Media
The type and condition of the media also affect backup performance. For best performance, use media that is the same LTO generation as the tape drives.
December 2021
181
User Guide--Spectra Stack Library
Chapter 8 -- Library Troubleshooting
FINDING EVENT INFORMATION
Finding Event Information
You can find error codes by viewing log files from the Maintenance > Logs and Traces > View Logs screen or downloading support tickets from the Maintenance > Download Support Ticket screen. See Viewing Log Files on page 159 or Downloading Drive Logs on page 165.
UNLOCKING THE MAGAZINE
It is recommended that you unlock the magazine using the OCP or RMI. If these methods fail, or if a magazine needs to be removed when the power to the library is off, you can release the magazine manually. Only one magazine or EE port can be open at a time.
Note: As a best practice, perform this procedure while applications are idle. While the magazine is extended, the library robotic assembly cannot move media.
Using the OCP or RMI
1. Log in as an administrator. 2. On the Home screen, click Open Magazine. The Open Magazine screen
displays.
December 2021
Figure 130 The Open Magazine screen.
182
User Guide--Spectra Stack Library
Chapter 8 -- Library Troubleshooting
Unloading a Stuck Tape
3. Click Open in the left or right magazine column within the module containing the magazine you want to unlock.
4. Click Submit. A message box indicates when the magazine has been unlocked.
5. Click OK to close the message. The Open Magazine screen shows that the magazine is now unlocked. Close the magazine access door after reinserting a magazine.
Note: If not removed, the magazines and the EE port relocks after 30 seconds.
Using the Manual Release
1. Open the magazine access door. 2. Insert a small flat head screwdriver or Torx driver into the appropriate
magazine release hole and gently push the tab in.
Caution Do not exert force once you encounter resistance. Doing so can damage the device.
Figure 131 The magazine release.
3. Close the magazine access door after reinserting a magazine.
UNLOADING A STUCK TAPE
If a tape is stuck in a tape drive, eject the tape from the drive from the Operation > Force Drive Media Eject screen. If a tape is stuck in a magazine, open the magazine (see Unlocking the Magazine on page 182), grasp the cartridge, and pull it out of the storage slot.
December 2021
183
User Guide--Spectra Stack Library
Chapter 8 -- Library Troubleshooting
IDENTIFYING A FAILED COMPONENT
Identifying a Failed Component
Using the OCP or RMI:
1. If necessary, activate the UID LEDs from the Maintenance > UID LED Control screen. This illuminates the blue LED on the front and rear of the controller module to identify the library containing the failed module or component.
2. Identify the module within the library that contains the failed component:
a. In the upper left of the Home screen, locate the module that indicates an error.
b. Click the module for information on the failed component.
December 2021
184
User Guide--Spectra Stack Library
CHAPTER 9
Event Codes
This chapter provides descriptions and possible solutions for error event codes.
Topic Error Events Warning Events Configuration Change Events Informational Events
page 185 page 194 page 200 page 201
ERROR EVENTS
Event Code 2000 2001 2002
2003
Message Text and Description
Failed to move cartridge.
Failed to exchange the cartridge.
The initial module discovery (detection of expansion modules) failed.
The librarys temperature has exceeded the critical limit.
Details and Solution
Verify the source and destination elements and retry the move operation.
Verify that all expansion modules are powered on and that the expansion interconnect cables are properly installed.
1. Verify that the chassis fan in each module is functioning
2. Verify that the drive cover plates are installed in all open drive bays.
3. Verify that all power supplies are installed and working properly.
4. Verify that the ambient room temperature is within specified limits.
185
Chapter 9 -- Event Codes
Event Code 2004
Message Text and Description Library startup failed.
Error Events
Details and Solution
1. If the robotic assembly fails to move through a certain area of the library:
Look through the window in the front panel and see if there are any obstructions.
Verify that both magazines in that module can be extended.
2. Verify that all modules have power and that any expansion modules are cabled correctly with the expansion interconnect cables.
3. Verify that the top and bottom cover plates are properly installed on the library.
4. Verify that the module alignment mechanisms at the rear of the library are locked in the proper positions.
5. Reboot the library. 6. If the robotic assembly moves front to
back, but not vertically, the robot shipping lock could be positioned incorrectly and should be moved to either the fully locked or fully unlocked position.
If the robotic assembly doesnt unlock the shipping lock after reboot: a. Move the robotic assembly to the
base from the Maintenance > Move Robotic to Base module screen. See Moving the Robotic Assembly to the Controller Module on page 167. b. Power off the library. c. Remove all cables from the controller module and unlock the alignment mechanism. d. Extend the controller module from the rack. e. Reposition the lock. Note: If the error persists, review library events for additional information. See Viewing Log Files on page 159.
December 2021
186
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Error Events
Event Code 2005 2006 2007 2008 2009 2010 2011
2012 2013 2014
2015
2016
Message Text and Description
Details and Solution
Robotic spooling cable failure.
Cable to spooling mechanism has failed.
Move command failed due to spooling mechanism failure.
Ensure that the spooling cable is fully seated in the controller module and correctly connected to the robotic assembly.
Exchange cartridge failed due to spooling mechanism failure.
Library test failed due to robotic assembly problem.
Review the test requirements and retry the test. If the test continues to fail, check for robotics obstructions or other robotics problems.
Library test failed due to spooling mechanism defect.
Drive power board has failed. Some drives might be powered off.
Ensure that the spooling mechanism is fully seated in the controller module and installed correctly with the robotic assembly.
1. Ensure that the drive power boards are fully seated in the module. See "Installing the New Drive Power Board" in Spectra Stack DC-DC Converter Replacement Instructions.
2. Power cycle the library.
Multiple bottom covers detected. Remove all bottom covers except for the bottom module in the library.
Multiple top covers detected.
Remove all top covers except for the top module in the library.
Bottom cover missing.
If the controller module cannot detect both a top and a bottom cover, the robotic mechanism will not move. 1. Install the bottom cover on the bottom
module in library.
2. Check the module interconnect cabling and module power cords.
Top cover missing.
If the controller module cannot detect both a top and a bottom cover, the robotic mechanism will not move. 1. Install the top cover on the bottom
module in library.
2. Check the module interconnect cabling and module power cords.
Module alignment mechanism is not locked properly.
Ensure that the alignment mechanisms for all modules above the bottom module are engaged and locked.
December 2021
187
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Error Events
Event Code 2017
2018 2021 2022 2023 2024 2025
2026 2027
Message Text and Description
Details and Solution
A communication problem between modules was detected.
1. Ensure that all modules are powered on.
2. Ensure that all module interconnect cables are properly attached.
3. Ensure that the alignment mechanisms for all modules above the bottom module are engaged and locked.
Too many unit position transmitter or detector failures.
1. Ensure that the alignment mechanisms for all modules above the bottom module are engaged and locked.
2. Power cycle the library.
Database access error.
1. Reboot the library.
2. If the error persists, restore the library configuration. See Saving, Restoring, and Resetting the Library Configuration on page 46.
Drive has been hot removed while in active status as LUN master. Tape drives must be powered off before removing them from the library.
Reinsert the removed drive in the same position from which it was removed.
Internal software error.
Reboot the library.
Exception thrown by application not handled.
An unrecoverable error occurred. Retry the operation and if the error persists reboot the library.
Move failure due to vertical robotic assembly positioning problem.
1. Check for obstructions, such as a cartridge sticking out, in the vertical pathway of the robotic assembly.
2. Verify that the robotic assembly is aligned and level within the library.
3. Verify that the rack is level front to back and side to side.
Failed moving the robot towards the back or front of the library.
Check for obstructions, such as a cartridge sticking out or cable impeding progress, in the horizontal pathway of the robotic assembly.
Move failed pulling cartridge from element.
Check for labels or cartridge misalignments that would prevent the cartridge from coming out of the slot or drive.
December 2021
188
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Error Events
Event Code 2028 2029
2030 2031 2032 2033 2034 2035 2036 2037 2038
Message Text and Description
Details and Solution
Move failed inserting cartridge to element.
Initialization failure due to robot front to back positioning.
Check for labels or cartridge misalignments that would prevent the cartridge from being inserted into the slot or drive.
1. Check for obstructions, such as a cartridge sticking out, in the vertical pathway of the robotic assembly.
2. Ensure that the alignment mechanisms for all modules above the bottom module are engaged and locked.
3. Verify that the rack is level front to back and side to side.
4. Check to see if the robotic assembly is stuck in its locking mechanism. If so, move the robotic assembly out of the locking mechanism and then enable the locking mechanism properly.
Failed during front to back movement.
Move failure due to right to left or left to right robot rotation failure.
Check for obstructions, such as a cartridge sticking out or cable impeding progress, in the horizontal pathway of the robotic assembly.
Initialization failure due to robot gripper positioning error.
Initialization failure due to robot vertical positioning error.
Check for obstructions, such as a cartridge sticking out, in the vertical pathway of the robotic assembly.
Cable to spooling mechanism has failed during initialization.
Ensure that the spooling mechanism is fully seated in the controller module and installed correctly with the robotic assembly.
Initialization failure due to robot gripper positioning error.
Check for obstructions in the gripper pathway of the robot such as a cartridge sitting in the shuttle of the robot.
Unintended termination of application process.
Reboot or power cycle system.
Robotic firmware version upgrade failed.
Reboot or power cycle system. If the problem persists, contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
Lost connection to Module.
Ensure that all modules are powered and have the interconnect cable properly attached. Reboot or power cycle the system.
December 2021
189
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Error Events
Event Code 2039 2040 2041 2042
2043
2044
2045
2046
Message Text and Description
Details and Solution
Cartridge left in robot gripper, unable to be moved to any open location.
Enable EE ports and ensure that some of them are free. Then power cycle library. If still failing, open covers and remove cartridge manually from gripper.
Wellness test failed with critical error.
See codes 2041-2051.
Wellness test failed because of unit Ensure that the alignment mechanism is
lock failed.
engaged in every module that is above
another module in the library
Wellness test failed because of top cover is missing.
Install the top cover on the top module of the library. Also check the module interconnect cabling and module power cabling. If the controller module cannot detect both a top and bottom cover the robot will not move.
Wellness test failed because of top cover is missing.
Wellness test failed because of drive power board has failed.
Install the bottom cover on the bottom module of the library. Also check the module interconnect cabling and module power cabling. If the controller module cannot detect both a top and bottom cover the robot will not move.
1. Ensure that the drive power boards are fully seated in the module. See "Installing the New Drive Power Board" in Spectra Stack DC-DC Converter Replacement Instructions.
2. Power cycle the Library.
Wellness test failed because of move media test failed.
Check for obstructions in the pathway of the robot such as a cartridge sticking out. Verify module alignment and frame alignment. Check if the robotic assembly is stuck in the lock mechanism. Move robotic assembly apart from lock mechanism and enable lock mechanism correctly.
Wellness test failed because of drive communication test failed.
Remove and reseat the drive tray to ensure that the drive is fully seated. If the issue persists then reset the drive. Check the drive dump for more information. See Downloading Drive Logs on page 165.
December 2021
190
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Error Events
Event Code 2047 2048 2049 2050 2051
2052 2053 2054
Message Text and Description
Details and Solution
Wellness test failed because the barcode scanning test failed.
Verify that there is no obstruction in front of the barcode scanning module on the cartridge table located on the robotic assembly. If the error persists replace the robotic assembly. See the Spectra Stack Spool Robotic Replacement Instruction.
Wellness test failed because the unlock of the right magazine failed.
Reboot the library and retry the test. If the error persists contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
Wellness test failed because the unlock of the left magazine failed.
Reboot the library and retry the test. If the error persists contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
Wellness test failed because the unlock of EE port bank failed.
Reboot the library and retry the test. If the error persists contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
Wellness test failed because of the failing robotics test.
Check for obstructions in the pathway of the robot such as a cartridge sticking out. Verify module alignment and frame alignment. Check if the robotic assembly is stuck in the lock mechanism. Move robotic assembly apart from lock mechanism and enable lock mechanism correctly. Ensure that the spooling cable is fully seated in the controller module and connected correctly to the robotic assembly.
An open magazine was detected in one or more modules and the robot movement has been stopped.
Ensure that all magazines are completely inserted and properly locked. Do not open magazines using the emergency release while the library is operating and the robot is moving.
An open top cover was detected and the robot movement has been stopped.
Ensure that the top cover is completely inserted and properly locked. Do not open top cover using the emergency release while the library is operating and the robot is moving.
An open bottom cover was detected and the robot movement has been stopped.
Ensure that the bottom cover is completely inserted and properly locked. Do not open bottom cover using the emergency release while the library is operating and the robot is moving.
December 2021
191
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Error Events
Event Code 2055
2056
2057
2058 2059 2060 2061 2062 2063 2064 2065 2066
Message Text and Description
Details and Solution
An open unit lock was detected and the robot movement has been stopped.
Ensure that all unit locks are properly locked. Do not open unit locks using the emergency release while the library is operating and the robot is moving.
Initialization failure due to picker push pull positioning error.
Check for obstructions in the horizontal pathway of the robotic assembly such as a cartridge sticking out or a cable impeding progress.
Robotic shipping lock in incorrect position.
Access the picker assembly and manually move the shipping lock lever to either a locked or unlocked position. After moving the shipping lock to the one of the correct positions, reboot the library.
Maximum temperature for Drive Power Board 1 has exceeded. Shutting down the system.
Check the chassis fan and replace the fan if defective. See the Spectra Stack Fan Replacement Instructions.
Maximum temperature for Drive Power Board 2 has exceeded. Shutting down the system.
Check the chassis fan and replace the fan if defective. See the Spectra Stack Fan Replacement Instructions.
Chassis CPU maximum temperature exceeded. Shutting down the system.
Check the chassis fan and replace the fan if defective. See the Spectra Stack Fan Replacement Instructions.
Move failed pulling cartridge from drive.
Check for labels or cartridge misalignments that would prevent the cartridge from coming out of the drive.
Move failed inserting cartridge to drive.
Check for labels or cartridge misalignments that would prevent the cartridge from coming out of the drive.
Move failed positioning picker in Contact Spectra Logic Technical Support.
front of drive.
See Contacting Spectra Logic on page 7.
Library test failed with critical error.
Contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
Library startup process failed because of robotics initialization issue.
Contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
Library startup process failed during inventory scan.
Contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
December 2021
192
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Error Events
Event Code 2067
2068
2069 2070 2071
2072 2073 2074 2075 2076
Message Text and Description
Details and Solution
For safety reason the robot movement was halted in place.
Ensure that all magazines, top or bottom covers and unit locks are completely inserted and properly locked. Do not open magazines using the emergency release or remove covers or unit locks while the library is operating and the robot is moving. Ensure that all modules are powered and have the interconnect cable properly attached.
An emergency stop condition was detected in one or more modules and prevented the robotic assembly from initialization.
Ensure that all magazines, top or bottom covers and unit locks are completely inserted and properly locked. Please insert all open magazines and install all necessary covers and unit locks before powering on the library. Ensure that all modules are powered and have the interconnect cable properly attached.
Initialization failure due to barcode reader error.
Contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
Inventory scan failed because of Elevator axis problem.
Check for obstructions in the vertical pathway of the robot such as a cartridge sticking out. Verify module alignment and rack alignment.
Cartridge on picker when trying to scan.
Verify that there is no obstruction in front of the barcode scanning module on the cartridge table located on the robotic assembly. If the error persists replace the robotic assembly. See the Spectra Stack Spool Robotic Replacement Instruction.
Top cover detected at an incorrect Examine the library and adjust the cover
position.
to the proper position.
Bottom cover detected at an incorrect position.
Examine the library and adjust the cover to the proper position.
The library startup failed due to a Reboot or power cycle system. GPIO error.
The library startup failed due to an error when trying to open the robotic serial port.
Reboot or power cycle system.
I2C bus signals invalid.
Contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
December 2021
193
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Event Code 2078
Message Text and Description
Incompatible robotic assembly without encoder detected.
Warning Events
Details and Solution
Upgrade the firmware to a version which supports encoder-less control (see Software Upgrades on page 161) or replace the robotic assembly with a compatible model with an encoder (see the Spectra Stack Spool Robotic Replacement Instruction).
WARNING EVENTS
Event Code 4000 4001 4002 4003
4004
4005
4006
December 2021
Message Text and Description A reported drive canister fan speed is too slow. There is a Fibre Channel Loop ID conflict. A drive sent a clean request. The drive configuration failed.
The drive status request failed.
Drive is reporting a critical TapeAlert.
A drive temperature reported is above the threshold.
Details and Solution
Ensure that there are no obstructions to the drive fans.
Change the FC to fabric or use a different loop setting.
Clean the drive with an approved cleaning cartridge.
1. Remove the drive from the library, reinsert it and then retry the operation.
2. If the drive installed is a different LTO generation than the drive previously installed, reset the library defaults and then reconfigure the drive.
3. Check the drive dump for more information. See Downloading Drive Logs on page 165.
1. Remove the drive from the library, reinsert it and then retry the operation.
2. If the problem persists, reset the drive. 3. Check the drive dump for more
information. See Downloading Drive Logs on page 165.
1. Power cycle the drive and then verify whether the drive reports the same TapeAlert.
2. Check the drive dump for more information. See Downloading Drive Logs on page 165.
1. Verify that the drive fan is spinning and not obstructed.
2. Verify that the ambient temperature is within specification.
194
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Warning Events
Event Code 4007 4008 4009
4010 4011 4012
4013
Message Text and Description Cartridge error.
Cleaning tape expired.
Firmware upgrade of one or multiple expansion modules failed.
Drive is not compatible with this library. Drive is not supported in this library. Move cartridge operation filed due to drive issue.
Exchange cartridge failed due to a drive issue.
Details and Solution
1. Remove the cartridge and inspect it for damage.
2. Retry the operation with another cartridge.
Discard the cleaning cartridge and retry the cleaning operation with a new cleaning cartridge.
The controller module must be able to communicate with a powered on and connected expansion module to perform the upgrade. 1. Reseat the expansion module controller. 2. Check the module interconnect cable
and power connections. 3. Retry the firmware upgrade.
Remove the incompatible drive. Only install drives that are supported by the library.
1. Check events occurring at the same time for drive problems.
2. Retry the operation with the same source and destination. If the problem persists, retry the operation with a different cartridge in the same drive.
3. Check the drive dump for more information. See Downloading Drive Logs on page 165.
1. Retry the operation with the same source and destination. If the problem persists, retry the operation with a different cartridge in the same drive.
2. Check the library event log for events associated with this drive. See Viewing Log Files on page 159.
3. Check the drive dump for more information. See Downloading Drive Logs on page 165.
December 2021
195
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Warning Events
Event Code 4014
4015
4016 4017 4018 4019 4020 4021
4022
4023 4024
Message Text and Description
Details and Solution
Library test failed due to a drive issue.
1. Verify the test parameters and then retry the test.
2. Check the library event log for events associated with this drive. See Viewing Log Files on page 159.
3. Check the drive dump for more information. See Downloading Drive Logs on page 165.
Power supply has failed. Redundancy is not available.
1. Ensure that all power supplies are installed properly.
2. Verify that all power sources are supplying power that is within the product requirements.
Backup configuration data to controller module failed.
Restore configuration data from chassis failed.
1. If possible, save the library configuration to a file.
2. Power cycle the library and retry the operation.
Firmware upgrade of one or more drives failed due to drive issue.
General drive firmware bundle upgrade failure.
1. Verify that the firmware file is correct for the drive.
2. Ensure that the drive is in a healthy state and does not have a cartridge loaded.
3. Retry the operation.
Database has been reset due to a Restore previously saved configuration problem that prevented the library data. from powering up.
Drive has been hot removed while in active status as data transfer device. Drives must be powered off before removing them from the library.
Reinsert the removed drive in the same position from which it was removed.
A full-height drive in incorrect boundary location. Full-height drives only operate in the very top, very bottom, or middle pair of half-height drive bays.
Reinstall the tape drive in an acceptable location.
Drive not cable (ports not linked up).
The tape drive must have an FC or SAS cable attached to transfer data and communicate with host applications.
One or two unit position transmitter/detector failures.
Contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
December 2021
196
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Warning Events
Event Code 4025 4027 4028
4029 4030 4031 4041
4044
4054 4060
4061 4062 4063
Message Text and Description
Details and Solution
Library test failed due to a cartridge error.
Library Test failed due to a cartridge error.
1. Remove the cartridge and inspect it for damage.
2. Retry the operation with another cartridge.
Drive cannot use this media due to it being an unknown or unsupported format. Possibly the media is the wrong generation of media.
Check that the LTO generation of the tape cartridge is the same generation indicated on the barcode label. Remove cartridges which are not compatible to your tape drives.
Incompatible media move operation blocked by media barcode ID check.
Check if Media barcode label is matching LTO generation. Replace label or remove incompatible media from your system.
Move cartridge operation failed due to media error.
Remove the cartridge and inspect it for damage. Retry the operation with another cartridge.
Exchange media failed due to media error.
Remove the cartridge and inspect it for damage. Retry the operation with another cartridge.
Wellness test failed because of power supply redundancy test failed.
Ensure all power supplies are installed properly (two per module), and that each power supply is connected to a valid power source.
One of the Library tests failed because of a source element or destination element is currently not accessible.
Contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
Chassis fan failed.
Check the chassis fan and replace the fan if defective. See the Spectra Stack Fan Replacement Instructions.
Connection to the KMIP server failed.
Verify username and password as well as all needed SSL certificates needed for connecting to the KMIP server. Verify that the KMIP server is reachable within the network.
Key not found on KMIP server.
Verify that the requested key is available on the KMIP server. Check the KMIP server logs for additional details.
Key creation on KMIP server failed.
Check the KMIP server logs for additional details about the key creation failure.
KMIP configuration invalid.
Use the KMIP configuration wizard to verify the KMIP configuration.
December 2021
197
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Warning Events
Event Code 4064 4065 4067 4068
4069
4071 4072
4073 4074 4075
Message Text and Description
Details and Solution
KMIP feature not licensed.
Disable KMIP or install appropriate license for KMIP feature.
A tape alert flag was reported by a Contact Spectra Logic Technical Support.
drive.
See Contacting Spectra Logic on page 7.
Cleaning cartridge will expire soon and should be replaced.
Replace the cartridge.
No cleaning cartridge found.
Auto cleaning is enabled, but the library contains no labeled cleaning cartridge. The library was unable to perform the auto clean function for one or more drives. Install a valid and labeled cleaning cartridge and then perform a load and unload on the drive that needs to be cleaned to initiate the auto cleaning.
Configuring the drive default map ID was not possible.
Ensure the drive is powered up, is communicating with the library, and has up to date firmware. If this error persists, contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
Power supply fan failed.
Verify the power supply fan is spinning and ensure there are no obstructions in the fan.
No cleaning cartridge in partition available for auto cleaning.
Auto cleaning is enabled, but the partition contains no labeled cleaning cartridge. The library was unable to perform the auto clean function for one or more drives in this partition. Install a valid and labeled cleaning cartridge into the partition and then perform a load and unload on the drive that needs to be cleaned to initiate the auto cleaning.
Medium source element empty.
Check the source slot visually and rescan inventory. Additionally check for valid and readable barcode label.
Medium source element empty.
Check the source slot visually and rescan inventory. Additionally check for valid and readable barcode label.
Cartridge lost while extracting it from slot/drive.
Check the source element and ensure that there are no obstructions in the pathway of the robot.
December 2021
198
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Warning Events
Event Code 4077
4078
4079
4080 4082
4085 4086
Message Text and Description Unlocking the right magazine failed.
Unlocking the left magazine failed.
Unlocking the EE port failed.
Wellness test failed with warning. Magazine release motor initialization failure.
Too many retries of drive command needed because of UnitAttention or NotReady condition. Move operation failed due to the inability accessing the database.
Details and Solution
Reboot the library and retry the operation. If the magazine needs to be removed to get access to the tape cartridges, first power down the library and then release the magazine manually. Only one magazine can be open at a time. If the problem persists, contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7
Reboot the library and retry the operation. If the magazine needs to be removed to get access to the tape cartridges, first power down the library and then release the magazine manually. Only one magazine can be open at a time. If the problem persists, contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7
Reboot the library and retry the operation. If the EE port needs to be removed to get access to the tape cartridges, first power down the library and then release the entire magazine manually. Only one magazine can be open at a time. If the problem persists, contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7
Contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
Reboot the library and if the error persists contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7. If magazines need to be removed to get access to the tape cartridges, first power down the library and then release one by one magazine manually. Only one magazine can be open at a time.
Contact Spectra Logic Technical Support. See Contacting Spectra Logic on page 7.
Ensure the network the library is connected to is operating normally and ensure the library is running the latest firmware. Library needs reboot.
December 2021
199
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Configuration Change Events
Event Code 4088
4093
Message Text and Description Library not properly calibrated. This may cause media movement failures.
Could not obtain an IP address from DHCP server.
Details and Solution
The library needs to be re-calibrated. Reboot the library to initiate a re- calibration of the system. Ensure the library firmware is up to date. If this event persists after a reboot of the library, or if calibration does not begin automatically upon restart, login as the Service user and manually initiate calibration via the Maintenance > Auto Calibration RMI menu.
Check the network configuration settings and check if the DHCP server is reachable. Use the network configuration menu or unplug the network cable and plug it in after a few seconds to trigger an automatic reconfiguration of the network interface.
CONFIGURATION CHANGE EVENTS
Event Code 8000 8001 8002 8003 8004 8005 8006 8007 8008 8009 8011 8012 8013 8014 8015 8016
Message Text and Description The configuration of a drive changed. The drive was added or removed from the system. A partition was added, removed, or changed. An EE port bank was enabled or disabled. Drive firmware changed due to firmware upgrade. The configuration of hostname/domain name has changed. The email configuration settings have changed. The configuration of a date/time format changed. The system language setting changed. The timezone configuration has changed. The network settings have changed. The firmware for all expansion modules has been upgraded. The NTP time synchronization configuration has changed. SSH access was enabled or disabled. Level of media generation checking has changed. Library reset to default settings invoked by user.
December 2021
200
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Informational Events
Event Code 8017 8019 8022 8024 8025 8026 8027 8028 8029 8030 8031 8032 8033 8034 8036 8037
Message Text and Description Library firmware changed. Robotic firmware version upgraded. RMI/OCP Timeout configuration changed. EE port/Magazine access control configuration changed. EE port/Magazine automatic re-lock duration changed. Robotics change detected. Power Board has changed. Power Supply has changed. The SNMP configuration changed. An SNMP target has been added. An SNMP target has been deleted. The SNMPv3 settings changed. The OCP module has been changed. Manual Drive reset executed. New chassis detected. Chassis has been removed.
INFORMATIONAL EVENTS
Event Code 9000 9001 9002 9003 9004 9005 9006 9007 9008 9009 9010
Message Text and Description A tape alert flag was reported by a drive. A drive is present in the system but powered off. The library was powered on. A move media command was executed. Inventory scan was performed. The library was powered down from the front panel. The network interface was enabled. The network interface was disabled. The system time was synchronized with an SNTP server. A magazine was unlocked and opened. A magazine was closed and locked.
December 2021
201
User Guide--Spectra Stack Library
Chapter 9 -- Event Codes
Informational Events
Event Code 9011 9012 9013 9014 9015 9016 9024 9025 9026 9027 9028 9029 9031 9032 9034 9035 9037 9038 9041 9042 9043 9045 9046
Message Text and Description An EE port bank was unlocked and opened. An EE port bank was closed and locked. A user logged into the RMI interface. A user logged out of the RMI interface. A user logged into the OCP interface. A user logged out of the OCP interface. Drive support ticket created. Library test started. Library test successfully finished. Library test stopped by user. Configuration backup to controller module was successful. Configuration restore from controller module was successful. Library Health Status changed to Status OK. Library health status changed to status Warning. New system controller detected. New library chassis detected. The library was rebooted. The library was rebooted through user interface. Key on KMIP server created. Drive cleaning completed. Drive cleaning was started. Library configuration data failed to duplicate on to the controller module. Chassis fan speed could not be determine.
December 2021
202
User Guide--Spectra Stack Library
CHAPTER 10
Technical Support
Spectra Logic Technical Support provides a worldwide service and maintenance structure, refined over many years to provide timely, professional service.
Important A valid BlueVision Software Support key is required in order to obtain technical
support.
Topic Accessing the Technical Support Portal
Create an Account Log Into the Portal Opening a Support Ticket Returns
this page page 204 page 205 page 205 page 210
ACCESSING THE TECHNICAL SUPPORT PORTAL
The Spectra Logic Technical Support portal provides access to the Knowledge Base, the current version of BlueVision software for the library, drive firmware, drive device drivers, and additional service and support tools. You can also open or update a support incident.
203
Chapter 10 -- Technical Support
Create an Account
Accessing the Technical Support Portal
Access to User Guides and compatibility matrices does not require you to create an account. You must create a user account and log in to access Release Notes or repair documents, to download the latest version of BlueVision software, or to open a support incident.
1. Access the Technical Support portal login page at support.spectralogic.com.
2. On the home page, click Register Now.
Figure 132 The Spectra Logic Technical Support portal home page.
3. Enter your registration information. Your account is automatically associated with the serial numbers of all Spectra Logic products owned by your site. If you have an invitation, follow the link and enter the invitation code.
December 2021
Figure 133 The Signup screen.
If you do not have an invitation, enter the requested information to create your account. When you are finished, click Submit.
When the account is approved, you receive an email with an initial password. Use your email address and the password provided in the email to log in to your account. After you log in, you can change your password if desired.
204
User Guide--Spectra Stack Library
Chapter 10 -- Technical Support
Log Into the Portal
Opening a Support Ticket
Use your email address and password to log into the Technical Support Portal.
OPENING A SUPPORT TICKET
You can open a support incident using the Spectra Logic Technical Support portal or telephone. Use the following instructions to open a support incident through the
portal, or skip to Contact Spectra Logic Technical Support by Phone on page 209.
December 2021
Figure 134 The Spectra Logic Technical Support portal home page.
1. Make notes about the problem, including what happened just before the problem occurred.
2. Gather the following information: Your Spectra Logic customer number Company name, contact name, phone number, and email address The library serial number (see Viewing Library and Module Status on page 124) Type of host system being used Type and version of host operating system being used Type and version of host storage management software being used
3. If necessary, log in to the Support Portal by clicking Login, enter your email address and password, and click Log in. Note: See Accessing the Technical Support Portal on page 203 if you have not previously created an account on the Technical Support portal.
205
User Guide--Spectra Stack Library
Chapter 10 -- Technical Support
Opening a Support Ticket
4. Submit a support incident. Use the following instructions to search for help before submitting a ticket, or skip to Submit an Incident Directly on page 208.
a. From any page, select Incident>Incidents & Inventory.
Figure 135 Select Incidents>Incidents & Inventory. b. Select Open or View Incidents.
Figure 136 Select Open or View Incidents.
December 2021
206
User Guide--Spectra Stack Library
Chapter 10 -- Technical Support
Opening a Support Ticket
c. In the Search dialog box, enter a term or phrase about your problem (1) and click Search (2).
Figure 137 Enter a search phrase and click Search.
d. If the search does not provide an answer, click Open a New Incident.
Figure 138 Click Open a New Incident. e. Continue with Step 5 on page 209.
December 2021
207
User Guide--Spectra Stack Library
Chapter 10 -- Technical Support
Opening a Support Ticket
Submit an Incident Directly
a. From any page, select Inventory>My Inventory.
b. Locate the row of the product for which you want to submit an incident and click Create Incident.
Figure 139 Click Create Incident. c. Continue with Step 5 on page 209.
December 2021
208
User Guide--Spectra Stack Library
Chapter 10 -- Technical Support
Opening a Support Ticket
5. On the Create Incident page, enter the requested information providing as much detail as possible. When you are finished, click Submit.
Figure 140 Enter information about your incident and click Submit.
Notes: If you have multiple libraries and need to determine the serial number of the affected library, see Viewing Library and Module Status on page 124.
If the serial number of the affected library is not listed, contact Technical Support (see Contacting Spectra Logic on page 7).
Contact Spectra Logic Technical Support by Phone
To contact Spectra Logic Technical Support by telephone, see Contacting Spectra Logic on page 7.
December 2021
209
User Guide--Spectra Stack Library
Chapter 10 -- Technical Support
RETURNS
Returns
Your Technical Support representative may ask you to return a problem component to Spectra Logic for analysis and servicing. After you complete a replacement procedure, return the defective part using ALL of the packaging that the replacement part arrived in (including any anti-static bags or foam inserts).
Caution
Severe damage can occur if the component is not packaged correctly. You may be invoiced if it is damaged due to improper or insufficient packaging.
Use the return label and instructions that were included with the replacement part when preparing to ship the component you are returning. If you cannot locate these, contact Spectra Logic for another copy (see Contacting Spectra Logic on page 7). The return label and Return Merchandise Authorization (RMA) printed on it are used to associate the returned component with your account. To avoid being invoiced for failure to return the component, do not ship the component back to Spectra Logic without the RMA return label.
December 2021
210
User Guide--Spectra Stack Library
APPENDIX A
Specifications
This appendix provides specifications for the Spectra Stack library.
Topic Physical Specifications Environmental Specifications Electrical specifications Regulatory specifications (CSA test conditions) Default Settings Barcode Label Specifications Electrostatic discharge
Preventing Electrostatic Damage Grounding Methods
page 211 page 213 page 214 page 214 page 215 page 217 page 220 page 220 page 221
PHYSICAL SPECIFICATIONS
Parameter Height Width Depth Weight
Unpackaged 10.5 inches (268 mm) 18.7 inches (475 mm) 35.1 inches (892 mm) Controller module: 78.2 lb (35.5 kg) Expansion module: 68.3 lb (31.0 kg)
Packaged 24.2 inches (615 mm) 31.5 inches (800 mm) 47.2 inches (1200 mm) Controller module: 120.1 lb (54.5 kg) Expansion module: 110.2 lb (50.0 kg)
211
Appendix A -- Specifications
Rack Requirements
Physical Specifications
The rack for the Spectra Stack library must meet the following requirements.
Caution
You must locate the rack on a level, hard-surfaced floor, such as cement or tile. Do not place the rack on a carpeted floor or anywhere else that poses risk for static
discharge that could damage your system or its drives.
The Stack library is designed to fit in a standard 19-inch, 4-post rack. Keep the following in mind when selecting a rack:
Make sure that the distance between the mounting surfaces on the front and rear posts is between 26.6 inches (67.5 cm) and 30.8 inches (78.2 cm).
Note: If you are using the adaptors to install the rack-mount kit in a rack with circular mounting cutouts, the distance between the front and rear posts must be at least 28.1 inches (71.3 cm), and not more than 32.3 inches (82 cm).
Allow approximately 3 inches (8 cm) of additional depth at the back of the rack for cable clearance.
Some racks may require at least 2 inches (5 cm) of clearance between the front door frame and the front mounting posts of the rack to allow the door to close.
Check your rack's specifications to make sure it accommodates the weight and depth of the Stack library.
Notes: Spectra Logic does not support the use of a two-post rack with a Stack library.
Threaded round hole racks are not supported.
An enclosed 19-inch, four-post rack is available for purchase from Spectra Logic. The rack has two doors and removable side panels. Contact Spectra Logic Sales for more information (see Contacting Spectra Logic on page 4).
In earthquake prone areas, provide restraints as necessary.
WARNING
In earthquake- prone areas, the rack must have stabilizing equipment or be anchored to the floor to eliminate the risk of tipping, which could lead to personal injury.
December 2021
212
User Guide--Spectra Stack Library
Appendix A -- Specifications
ENVIRONMENTAL SPECIFICATIONS
Environmental Specifications
Parameter Temperature Operating Non-operating Recommended operating temperature Temperature shock immunity maximum rate of change Miscellaneous Dust concentration
Altitude Humidity Operating Non-operating
Specification
41� F to 104� F (5� C to 40� C) -40� F to 140� F (-40� C to 60� C) 50� F to 95� F (10� C to 35� C) 27� F per hour (10� C per hour)
Less than 200 micrograms per cubic meter / 1.3 cubic yards. 16,450 feet (5000 meters)
10% to 80% RH non-condensing 5% to 90% RH non-condensing
LTO-9 Tape Drive Environmental Specifications
Dry-bulb Temperature
Maximum Temp Rate of Change
Recommended 59� F to 77� F 9� F / hour Environment 15� C to 25� C 5� C / hour
Relative Humidity (noncondensing)
20% to 50%
Allowable Environment
59� F to 95� F 9� F / hour 15� C to 35� C 5� C / hour
Shipping Environment
-40� F to 140� F -40� C to 60� C
20% to 50% 72� F (22� C) dew point max
10% to 90% non- condensing
Maximum
Maximum
Humidity Rate Altitude
of Change
5% / hour with 10000 ft
no
3048 m
condensation
5% / hour with 10000 ft
no
3048 m
condensation
40000 ft 12192 m
December 2021
213
User Guide--Spectra Stack Library
Appendix A -- Specifications
ELECTRICAL SPECIFICATIONS
Electrical specifications
Parameter Current Voltage Input Frequency Power
Specification 5.0-3.5 A 100-240 V 50-60 Hz 350 watts
REGULATORY SPECIFICATIONS (CSA TEST CONDITIONS)
Note: The CSA test conditions might differ from the product specification limits.
Parameter
Tested Condition or Value
Equipment mobility
Stationary - rack mount
Connection to the mains
Pluggable - Type A
Operating condition
Continuous
Access location
Operator accessible
Over voltage category (OVC)
OVCII
Mains supply tolerance (%) or absolute mains supply values
-10%, +6%
Tested for IT power systems
No
IT testing, phase-phase voltage (V)
N/A
Class of equipment
Class I
Considered current rating (A)
20 A (branch circuit protection)
Pollution degree (PD)
PD 2
IP protection class
IPXO
Altitude during operation (m)
Maximum 6565 feet (2000 meters)
Altitude of test laboratory (m)
125 feet (38 meters)
Mass of equipment (kg)
Maximum 55.1 lb (25 kg)
Manufacturer's Declared Ambient (0C) 104� F (40� C)
December 2021
214
User Guide--Spectra Stack Library
Appendix A -- Specifications
DEFAULT SETTINGS
Default Settings
Parameter
Default Setting
Users and Passwords Administrator login
User login
Network Configuration (EthO) DHCP Host name IP address Subnet mask Default gateway Network Configuration IPv4 DHCPv4 IPv6 Static V6 Stateless V6 DNS Configuration Network Access Services Primary network interface (ethO) SSH SSL LDAP
User: administrator Password: blank User: user Password: blank
Enabled Blank (obtain from DHCP) (obtain from DHCP) (obtain from DHCP)
Enabled Enabled Disabled Disabled Disabled Blank
Enabled Enabled Disabled Disabled
Slots
EE ports Administrator password required for EE port removal Reserved slots Partitions
Disabled Enabled
0 Disabled (no partitions)
Reset During Reset Default Settings? No Yes
No No No No No No
Disabled with configuration retained Yes Yes Yes All deleted leaving a single partition
December 2021
215
User Guide--Spectra Stack Library
Appendix A -- Specifications Parameter
Default Setting
Date and Time NTP /SNTP setting Date Time Time zone Email notifications (SMTP)
Disabled Blank or existing Blank or existing GMT Disabled
SNMP/SMI-S SNMP v1, v2
Disabled
SCSI Defaults
Library product ID - INQUIRY product ID string (Std Inquiry page)
Python
Library vendor ID - INQUIRY vendor ID string (Std Inquiry page)
Spectra
SCSI element addressing Miscellaneous Settings
Starting element addresses
Values in decimal: Slot: 1001 Picker: NA Drives: 1 I/E slots: 101
Values in hexadecimal: Slot: Ox3E9 Picker: NA Drives: Ox1 I/E slots: Ox65
Return drive serial numbers to host
Enabled
Return barcodes to host (RES SCSI Enabled data)
Barcode format and length returned to host
8 digits, left justified
Language settings
English
Default Settings Reset During Reset Default Settings? Configuration retained
Disabled with configuration retained Disabled with configuration retained
Yes
Yes Yes
December 2021
216
User Guide--Spectra Stack Library
Appendix A -- Specifications Parameter
Default Setting
Miscellaneous Settings Continued
Auto unload (library controlled unload)
Enabled
Log tracing
Continuous, all levels selected
Ignore barcode media ID
Disabled
All licensed features
Disabled
Licenses
Not applicable
OCP
Barcode format displayed on OCP 8 digits, left justified
OCP contrast
Screen saver
Drive Defaults
Drive speed and topology setting Auto speed/Fabric
Drive hosting the library LUN
Drive 1 or the lowest numbered existing drive
Drive power
All drives powered on
Auto clean
Disabled
Barcode Label Specifications Reset During Reset Default Settings?
Yes Yes Disabled, configuration retained where possible Not deleted
Yes No Yes
Yes Yes
Yes Yes
BARCODE LABEL SPECIFICATIONS
Symbology The barcode labeling scheme used on Spectra Logic certified media uses the barcode symbology of USS-39. You can obtain a complete description and definition of this symbology from the Automatic Identification Manufacturers (AIM) specification, the Uniform Symbol Specification (USS-39), and the ANSI MH10.8M-1993 ANSI Barcode specification.
Application and Orientation The barcode label must be applied to the cartridge so that it fits within the label recess on the edge of the cartridge without curling up on the sides or ends. The label must be oriented so that the barcode characters are along the edge closest to the hub side of the cartridge.
December 2021
217
User Guide--Spectra Stack Library
Appendix A -- Specifications
Barcode Label Specifications
Printed Characters The label can have human-readable alphanumeric characters printed along the top or bottom edge of the label provided there is no conflict or interference with the automation code. This text must include the barcode data, but can also include additional text. The format and colors of the human readable characters is up to the customer and label vendor. For location restrictions, see Detailed Specifications for LTO Cartridge Barcodes on page 219.
Note: When using barcode labels with alphanumeric characters along the bottom edge, the label must be positioned so that barcode is at least 13.72 mm below the top edge of the cartridge to ensure that the barcode reader can read the label.
Barcode Data The library supports barcode data strings consisting of from 1 to 16 characters, including an optional checksum character. Quiet zones precede and follow the start and stop characters.
The barcode data string on standard Spectra Logic barcode labels consists of a start character, eight alphanumeric characters, a checksum character, and the stop character. Quiet zones precede and follow the start and stop characters.
The first six (6) characters following the start character can be any combination of upper case A-Z or 0-9 (for example, ABC123) to identify the cartridge Volume Serial Number. The use of "CLN" and "DG{space}" at the beginning of the volume identifier is reserved.
The volume identifier "CLNvnn" is reserved for cleaning cartridges. When a drive requires cleaning, it requests a specific type of cleaning cartridge. The "v" field is an alphanumeric field to identify cleaning cartridge applications, "U" for Universal Cleaning Cartridges or a drive unique identifier. The "nn" alphanumeric field is used to track individual cleaning cartridge activity (that is, usage and life).
The volume identifier "DG{space}vnn" is reserved for diagnostic and service cartridges.
The last two (2) characters are the media identifier and indicate the cartridge Media Type (for example, "L" for LTO and "6" for an LTO-6 cartridge. In IBM LTO tape drives, the value of the media identifier on cleaning cartridges is ignored, although a valid value must be present.
The barcode string can be printed in either direction on the label and
must begin and end with a valid start/stop character ( * ).
The label must be printed so that barcode data is positioned along the edge of the label that is closest to the hub side of the cartridge.
The AIM Uniform Symbol USS-39 specification provides detailed information about the format of the start character, the series of characters that make up the barcode data, the optional checksum character, and the stop character.
December 2021
218
User Guide--Spectra Stack Library
Appendix A -- Specifications
Barcode Label Specifications
Detailed Specifications for LTO Cartridge Barcodes
Figure 141 shows the dimensional specifications for LTO labels with the alphanumeric characters above the barcode.
Barcode start character
Alphanumeric characters
Barcode stop character
17 mm +0/�0.8
11.1 mm, minimum
74.088 mm, nominal
Quiet Zone 4.32 mm, minimum
79 mm +0/�.8
Quiet Zone 4.32 mm, minimum
Figure 141 Barcode specifications for LTO media; alphanumeric characters on top.
Note: When using barcode labels with alphanumeric characters along the bottom edge, the label must be positioned so that barcode is at least 13.72 mm below the top edge of the cartridge to ensure that the barcode reader can read the label.
December 2021
LTO Barcode Element Specifications
For the official IBM barcode label specification, see https://ibm.com/ support/docview.wss?uid=ssg1S7000429. Unless otherwise specified, tolerances are X.XXX � 0.127 mm, X.XXX � 0.762 mm.
Minimum symbol height is 11.1 mm, measured to the inside of the label's edge.
The wide-to-narrow ratio is 2.75. The narrow element width is 0.432 mm +0.03 mm or �0.076 mm. The nominal width of the wide spaces and bars is 1.188 mm. The inter-character gap is 0.432 mm +0.03/�0.076 mm. The minimum quiet zone at the beginning and end of a printed barcode
string is 4.32 mm (10 times the narrow element width). The total nominal barcode string length (including quiet zones) is
74.088 mm. The edge of the barcode is the edge of the printed area associated with
the bar. The edge roughness is the transition encountered as a horizontal line is moved vertically from all black to all white. The edge roughness maximum is 0.038 mm. Variation between all bars, white and black, must be less than �0.0381 mm.
219
User Guide--Spectra Stack Library
Appendix A -- Specifications
Electrostatic discharge
LTO Physical Label Specifications
Label stock must fit within the label recess on the face of the cartridge without curling up on the sides or ends (79 mm X 17 mm +0/�0.8).
Minimum length sufficient for the quiet zones, start-stop, and data characters (nominal 74.088 mm).
Minimum width no less than 1.5 mm narrower than the cartridge label recess width. Corners are cut with a 1.5 mm radius.
Maximum label thickness, including the RFID tag, if present, together with any associated layers and adhesives cannot exceed 0.40 mm.
The label and adhesive must have an environmental performance to match or exceed the environmental specifications of the cartridge to which it is applied.
ELECTROSTATIC DISCHARGE
To prevent damaging the system, be aware of the precautions you must follow when setting up the library or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.
Preventing Electrostatic Damage
To prevent electrostatic damage, observe the following precautions: Always be properly grounded when touching a static-sensitive
component or assembly. Avoid hand contact by transporting and storing products in static-safe
containers. Keep electrostatic-sensitive parts in their containers until they arrive at
static-free workstations. Place parts on a grounded surface before removing them from their
containers. Avoid touching pins, leads, or circuitry.
December 2021
220
User Guide--Spectra Stack Library
Appendix A -- Specifications
Grounding Methods
Electrostatic discharge
There are several methods for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts:
Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm (� 10 percent) resistance in the ground cords. To provide proper ground, wear the strap snug against the skin.
Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.
Use conductive field service tools.
Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part.
Note: For more information on static electricity, or assistance with product installation, contact your authorized reseller.
December 2021
221
User Guide--Spectra Stack Library
APPENDIX B
Regulatory Information
Note: To comply with the following regulations and standards, the library must be properly installed in an office or industrial environment with shielded cables and adequate grounding of the SCSI bus and the input power.
RECYCLING AND DISPOSAL
CE MARK
Disposal of waste equipment by users in private household in the European Union and Norway
This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your equipment by handling it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at this time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
The CE mark is a mandatory conformity mark on many products placed on the single market in the European Economic Area (EEA). The CE marking certifies that a product has met EU consumer safety, health or environmental requirements.
CCL MARK
222
Appendix B -- Regulatory Information
FCC (UNITED STATES)
FCC (United States)
The computer equipment described in this manual generates and uses radio frequency (RF) energy. If the equipment is not installed and operated in strict accordance with the manufacturers instructions, interference to radio and television reception might result.
Tested To Comply With FCC Standards For Home or Office Use
This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Part 15, Class A, of the FCC Rules, is designed to provide reasonable protection against radio and television interference in a residential installation. Although the equipment has been tested and found to comply with the allowed RF emission limits, as specified in the above-cited Rules, there is no guarantee that interference will not occur in a particular installation. Interference can be determined by turning the equipment off and on while monitoring radio or television reception. The user may be able to eliminate any interference by implementing one or more of the following measures:
Reorient the affected device and/or its receiving antenna. Increase the distance between the affected device and the computer
equipment. Plug the computer and its peripherals into a different branch circuit
from that used by the affected device. If necessary, consult an experienced radio/television technician for
additional suggestions.
CANADIAN VERIFICATION
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations (ICES-003, Class A).
December 2021
223
User Guide--Spectra Stack Library