Driver LCI 150/325-1050/300 o4a sl PRE mod - Tridonic

For further information see masterCONFIGURATOR manual. 6.15 deviceCONFIGURATOR. PC (windows) based software application to transfer parameters into ...

LED Driver INDUSTRY Linear Dimming Driver LCI ... - Tridonic

Subject to change without notice. Information provided without guarantee. www.tridonic.com 3 Data sheet 09/21-LC562-10 LED Driver INDUSTRY Linear Dimming Specific technical data

PDF preview unavailable. Download the PDF instead.

Driver LCI 150W 325-1050mA o4a sl PRE mod en
LED Driver INDUSTRY Linear Dimming

Driver LCI 150W 325-1050mA 300V o4a sl PRE mod (INDUSTRY) premium series non-SELV

Product description · Constant current built-in Driver for LED, particularly
suitable for industrial applications in moderate environments such as semiconductor factories or logistic warehouses · Dimming range 1 ­ 100 % · Adjustable output current between 325 and 1,050 mA · Max. output power 150 W · Suitable for mains voltage peaks (burst/surge) up to 4 kV · Expanded temperature range of -25 ... +50 °C · Nominal life-time up to 100,000 h (at ta 50 °C) · 5-year guarantee
Housing properties · White slim metal casing · Type of protection IP20
Interfaces · one4all (DALI-2 DT 6, DSI, switchDIM, corridorFUNCTION) · ready2mainsTM (configuration and dimming via mains) · Terminal blocks: 0° push terminals
Functions · Adjustable output current in 1-mA-steps (I-SELECT resistor or
eD) · Constant light output function (CLO) · Power-up fading at AC · Intelligent Temperature Guard (overtemperature protection) · Intelligent Voltage Guard (overvoltage and undervoltage
shutdown) · Protective features (overtemperature, short-circuit, overload,
no-load, input voltage range) · Suitable for emergency lighting acc. to EN 50172
Benefits · Application-oriented operating window for maximum compatibility · Best energy savings due to low stand-by losses · Flexible configuration via DALI, ready2mainsTM and I-SELECT 2 · Reliability proven by life-time up to 100,000 h and
5-year guarantee · High reliability through the selection of exclusive components
Typical applications · For linear/area lighting in industry applications
·
È Standards, page 5

Data sheet 04/20-LC562-8

Subject to change without notice. Information provided without guarantee.

www.tridonic.com

1

LED Driver INDUSTRY Linear Dimming

EL
Driver LCI 150W 325-1050mA 300V o4a sl PRE mod (INDUSTRY) premium series non-SELV

Technical data

Rated supply voltage

220 ­ 240 V

AC voltage range

198 ­ 264 V

DC voltage range

176 ­ 280 V

Mains frequency

0 / 50 / 60 Hz

Overvoltage protection

320 V AC, 48 h

Typ. current (at 230 V, 50 Hz, full load)1 2

681 mA

Typ. current (220 V, 0 Hz, full load, 15 % dimming level)2 119 mA

Leakage current (at 230 V, 50 Hz, full load)1 2

< 250 µA

Max. input power

157.1 W

Typ. efficiency (at 230 V / 50 Hz / full load)2

95 %

 (at 230 V, 50 Hz, full load)1

0.98

Typ. power input on stand-by3

< 0.25 W

Typ. input current in no-load operation

78 mA

Typ. input power in no-load operation

0.54 W

In-rush current (peak / duration)

17.7 A / 162 s

THD (at 230 V, 50 Hz, full load)1

< 4 %

Starting time (at 230 V, 50 Hz, full load)1

< 0.6 s

Starting time (DC mode)

< 0.4 s

Switchover time (AC/DC)7

< 0.4 s

Turn off time (at 230 V, 50 Hz, full load)

< 2.4 ms

Output current tolerance1 6

± 3 %

Max. output current peak (non-repetitive)

 output current + 30 %

Output LF current ripple (< 120 Hz) Output PstLM Output SVM

± 2 %  1  0.4

Max. output voltage (no-load voltage)

350 V

Dimming range

1 ­ 100 %

Mains surge capability (between L ­ N)

4 kV

Mains surge capability (between L/N ­ PE)

4 kV

Surge voltage at output side (against PE)

4 kV

Type of protection

IP20

Life-time

up to 100,000 h

Dimensions L x W x H

360 x 30 x 28 mm

side fixing feature

Ø

Ordering data
Type LCI 150/325-1050/300 o4a sl PRE mod

Article number

Packaging carton

28002054 10 pc(s).

Packaging pallet
550 pc(s).

Weight per pc. 0.321 kg

Data sheet 04/20-LC562-8

Subject to change without notice. Information provided without guarantee.

www.tridonic.com

2

LED Driver INDUSTRY Linear Dimming

Specific technical data

Type

Output Min. forward Max. forward Max. output Typ. power consumption Typ. current consumption Max. casing

Ambient

I-SELECT 2

current4 6 voltage voltage

power (at 230 V, 50 Hz, full load) (at 230 V, 50 Hz, full load) temperature tc temperature ta max. resistor value5

325 mA 80 V

300 V

97.5 W

101.2 W

447 mA

68 °C

-25 ... +50 °C

open

400 mA 80 V

300 V 120.0 W

124.3 W

546 mA

68 °C

-25 ... +50 °C

12.50 k

450 mA 80 V

300 V 135.0 W

139.7 W

611 mA

68 °C

-25 ... +50 °C

11.11 k

500 mA 80 V

300 V 150.0 W

155.1 W

677 mA

68 °C

-25 ... +50 °C

10.00 k

550 mA 80 V

273 V 150.0 W

155.2 W

678 mA

70 °C

-25 ... +50 °C

9.09 k

600 mA 80 V

250 V 150.0 W

155.4 W

679 mA

70 °C

-25 ... +50 °C

8.33 k

650 mA 80 V

LCI 150/325-1050/300 o4a sl PRE mod

700 mA

80 V

750 mA 80 V

231 V 214 V 200 V

150.0 W 150.0 W 150.0 W

155.5 W 155.7 W 155.8 W

679 mA 680 mA 681 mA

70 °C 70 °C 70 °C

-25 ... +50 °C -25 ... +50 °C -25 ... +50 °C

7.69 k 7.14 k 6.67 k

800 mA 80 V

188 V 150.0 W

156.0 W

682 mA

70 °C

-25 ... +50 °C

6.25 k

850 mA 80 V

176 V 150.0 W

156.2 W

683 mA

70 °C

-25 ... +50 °C

5.88 k

900 mA 80 V

167 V 150.0 W

156.5 W

684 mA

72 °C

-25 ... +50 °C

5.56 k

950 mA 80 V

158 V 150.0 W

156.7 W

684 mA

72 °C

-25 ... +50 °C

5.26 k

1,000 mA 80 V

150 V 150.0 W

156.9 W

685 mA

72 °C

-25 ... +50 °C

5.00 k

1,050 mA 80 V

143 V 150.0 W

157.1 W

686 mA

72 °C

-25 ... +50 °C short circuit (0 )

1 Valid at 100 % dimming level.

2 Depending on the selected output current.

3 Depending on the DALI traffic at the interface.

4 The table only lists a number of possible operating points but does not cover each single point. The output current can be set within the total value range in 1-mA-steps.

5 Not compatible with I-SELECT (generation 1). Calculated resistor value.

6 Output current is mean value.

7 Valid for immediate change of power supply type otherwise the starting time is valid.

Data sheet 04/20-LC562-8

Subject to change without notice. Information provided without guarantee.

www.tridonic.com

3

LED Driver INDUSTRY Linear Dimming
I-SELECT 2 PLUG PRE / EXC

ACCESSORIES

Product description · Ready-for-use resistor to set output current value · Compatible with LED Driver featuring I-SELECT 2 interface;
not compatible with I-SELECT (generation 1) · Resistor is base insulated · Resistor power 0.25 W · Current tolerance ± 2 % additional to output current tolerance · Compatible with LED Driver series PRE and EXC

xxxx xxxx

7,5

5,5

4,5

13,5

9

Example of calculation for third party resistors · R [k] = 5 V / I_out [mA] x 1000 · E96 resistor value used · Resistor value tolerance  1 %; resistor power  0.1 W;
base insulation necessary · When using a resistor value beyond the specified range, the
output current will automatically be set to the minimum value (resistor value too big), respectively to the maximum value (resistor value too small)

3,5

Ordering data

Type

Article

Resistor

Colour Marking Current

number

value

I-SELECT 2 PLUG 325MA BL 28001109 Blue 0325 mA 325 mA 15.40 k

I-SELECT 2 PLUG 350MA BL 28001110 Blue 0350 mA 350 mA 14.30 k

I-SELECT 2 PLUG 375MA BL 28001111 Blue 0375 mA 375 mA 13.30 k

I-SELECT 2 PLUG 400MA BL 28001112 Blue 0400 mA 400 mA 12.40 k

I-SELECT 2 PLUG 425MA BL 28001151 Blue 0425 mA 425 mA 11.80 k

I-SELECT 2 PLUG 450MA BL 28001113 Blue 0450 mA 450 mA 11.00 k

I-SELECT 2 PLUG 475MA BL 28001252 Blue 0475 mA 475 mA 10.50 k

I-SELECT 2 PLUG 500MA BL 28001114 Blue 0500 mA 500 mA 10.00 k

I-SELECT 2 PLUG 525MA BL 28001960 Blue 0525 mA 525 mA 9.53 k

I-SELECT 2 PLUG 550MA BL 28001115 Blue 0550 mA 550 mA 9.09 k

I-SELECT 2 PLUG 600MA BL 28001116 Blue 0600 mA 600 mA 8.25 k

I-SELECT 2 PLUG 650MA BL 28001117 Blue 0650 mA 650 mA 7.68 k

I-SELECT 2 PLUG 700MA BL 28001118 Blue 0700 mA 700 mA 7.15 k

I-SELECT 2 PLUG 750MA BL 28001119 Blue 0750 mA 750 mA 6.65 k

I-SELECT 2 PLUG 800MA BL 28001120 Blue 0800 mA 800 mA 6.19 k

I-SELECT 2 PLUG 850MA BL 28001121 Blue 0850 mA 850 mA 5.90 k

I-SELECT 2 PLUG 900MA BL 28001122 Blue 0900 mA 900 mA 5.62 k

I-SELECT 2 PLUG 950MA BL 28001123 Blue 0950 mA 950 mA 5.23 k

I-SELECT 2 PLUG 1000MA BL 28001124 Blue 1000 mA 1,000 mA 4.99 k

I-SELECT 2 PLUG 1050MA BL 28001125 Blue 1050 mA 1,050 mA 4.75 k

I-SELECT 2 PLUG MAX BL 28001099 Blue MAX MAX 0.00 k

Packaging Weight

bag

per pc.

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

10 pc(s). 0.001 kg

Data sheet 04/20-LC562-8

Subject to change without notice. Information provided without guarantee.

www.tridonic.com

4

LED Driver INDUSTRY Linear Dimming

1. Standards
EN 55015 EN 60068-2-27 (shock ­ test case: 1,000 shocks in 6 directions with 30 g / 18 ms) EN 60068-2-64 (vibration ­ test case: acc. to table A.1 transport / category 2) EN 61000-3-2 EN 61000-3-3 EN 61347-1 EN 61347-2-13 EN 62384 EN 61547 EN 62386-101 (DALI-2) EN 62386-102 (DALI-2) EN 62386-207 (DALI-2) According to EN 50172 for use in central battery systems According to EN 60598-2-22 suitable for emergency lighting installations

2. Thermal details and life-time

2.1 Expected life-time

Type

Output current

325 ­ 500 mA

LCI 150/325-1050/300 o4a sl PRE mod >500 ­ 850 mA

>850 ­ 1,050 mA

ta tc Life-time tc Life-time tc Life-time

40 °C 60 °C >100,000 h 62 °C >100,000 h 63 °C >100,000 h

45 °C 62 °C >100,000 h 66 °C >100,000 h 67 °C >100,000 h

50 °C 68 °C >100,000 h 70 °C 100,000 h 72 °C 80,000 h

The LED Driver is designed for a life-time stated above under reference conditions and with a failure probability of less than 10 %.
The relation of tc to ta temperature depends also on the luminaire design. If the measured tc temperature is approx. 5 K below tc max., ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request.

3. Installation / wiring
3.1 Circuit diagram
­ V / / Hz L N

DALI/DSI
­ V / / Hz L N

LCI / - /

PRI SEC

~ o a sl PRE mod ~

LED ­ LED

Isel -

Isel - (GND)

DA/N

DA/L

3.2 Wiring type and cross section Solid wire with a cross section of 0.5 ­ 1.5 mm². Strip 8 ­ 9 mm of insulation from the cables to ensure perfect operation of terminals.
LED module/LED Driver/supply
wire preparation: 0.5 ­ 1.5 mm²
8 ­ 9 mm
R 3.3 Loose wiring

LCI / - /

PRI SEC

~ o a sl PRE mod ~

LED ­ LED

Isel -

Isel - (GND)

N

DA/N

R

L

DA/L

switchDIM ­ V
/ Hz

For wiring in dimming operation with ready2mains refer to the ready2mains Gateway datasheet.

Loosen wire through twisting and pulling or using a Ø 1mm release tool

Data sheet 04/20-LC562-8

Subject to change without notice. Information provided without guarantee.

www.tridonic.com

5

LED Driver INDUSTRY Linear Dimming

3.4 Wiring guidelines
· Run the secondary lines separately from the mains connections and lines to achieve good EMC performance.
· The max. secondary cable length is 2 m (4 m circuit), this applies for LED output as well as for I-SELECT 2.
· For good EMC performance, keep the LED wiring as short as possible. · Secondary switching is not permitted. · The LED Driver has no inverse-polarity protection on the secondary side.
Wrong polarity can damage LED modules with no inverse-polarity protection. · Wrong wiring of the LED Driver can lead to malfunction or irreparable
damage. · With mains transients of 4 kV can voltage peaks up to 4 kV occur against
PE at the output of the LED Driver. This has to be considered concerning the dielectric strength of the LED module (insulation against PE). · To avoid the damage of the Driver, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.).

Make sure that the LED Driver is operated within the given window under all operating conditions. Special attention needs to be paid at dimming and DC emergency operation as the forward voltage of the connected LED modules varies with the dimming level, due to the implemented amplitude dimming technology. Coming below the specified minimum output voltage of the LED Driver may cause the device to shut-down. See chapter "6.11 Light level in DC operation" for more information.
4.2 Efficiency vs load

E iciency [ ]

3.5 Hot plug-in

Hot plug-in is not supported due to residual output voltage of > 0 V. If a LED load is connected the device has to be restarted before the output will be activated again. This can be done via mains reset or via interface (DALI, DSI, switchDIM, ready2mains).
3.6 Earth connection

4.3 Power factor vs load

Load [ ]

Power factor

The earth connection is conducted as protection earth (PE). The LED Driver can be earthed via earth terminal or metal housing. If the LED Driver will be earthed, protection earth (PE) has to be used. There is no earth connection required for the functionality of the LED Driver. Earth connection is recommended to improve following behaviour: · Electromagnetic interferences (EMI) · LED glowing at stand-by · Transmission of mains transients to the LED output

In general it is recommended to earth the LED Driver if the LED module is mounted on earthed luminaire parts respectively heat sinks and thereby representing a high capacity against earth.

3.7 I-SELECT 2 resistors connected via cable
For details see: http://www.tridonic.com/com/en/download/technical/LCA_PRE_LC_EXC_ProductManual_en.pdf.

4.4 THD vs load

Load [ ]

4. Electrical values
4.1 Operating window

THD [ ]

Output voltage [V]

Output current [mA] Operating window 100 % Operating window dimmed
Data sheet 04/20-LC562-8 Subject to change without notice. Information provided without guarantee.

Load [ ]
mA mA mA
mA
100 % load corresponds to the max. output power (full load) according to the table on page 2.

www.tridonic.com

6

LED Driver INDUSTRY Linear Dimming

4.5 Maximum loading of automatic circuit breakers in relation to inrush current

Automatic circuit breaker type Installation Ø LCI 150/325-1050/300 o4a sl PRE mod

C10 1.5mm2
28

C13 1.5mm2
33

C16 2.5mm2
36

C20 4mm2
41

B10 1.5mm2
17

B13 1.5mm2
20

B16 2.5mm2
22

B20 4mm2
25

Inrush current

I
max
17.7 A

time 162 s

This are max. values calculated out of inrush current! Please consider not to exceed the maximum rated continuous current of the circuit breaker. Calculation uses typical values from ABB series S200 as a reference. Actual values may differ due to used circuit breaker types and installation environment.

4.6 Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in %

LCI 150/325-1050/300 o4a sl PRE mod

THD 3. 5.

7.

9.

11.

<4 <1 <4 <1

< 1

< 1

4.7 Dimming
Dimming range 1% to 100% Digital control with: · DSI signal: 8 bit Manchester Code
Speed 1% to 100% in 1.4 s · DALI signal: 16 bit Manchester Code
Speed 1% to 100% in 0.2s Programmable parameter: Minimum dimming level Maximum dimming level Default minimum = 1% Programmable range 1%  MIN  100% Default maximum = 100% Programmable range 100%  MAX  1%
Dimming curve is adapted to the eye sensitiveness. Dimming is realized by amplitude dimming.

5.2 Control input ready2mains (L, N)
The digital ready2mains protocol is modulated onto the mains signal which is wired to the mains terminal (L and N).
5.3 switchDIM
Integrated switchDIM function allows a direct connection of a pushbutton for dimming and switching. Brief push (< 0.6 s) switches LED Driver ON and OFF. The dimm level is saved at power-down and restored at power-up. When the pushbutton is held, LED modules are dimmed. After repush the LED modules are dimmed in the opposite direction. In installations with LED Drivers with different dimming levels or opposite dimming directions (e.g. after a system extension), all LED Drivers can be synchronized to 50% dimming level by a 10 s push. Use of pushbutton with indicator lamp is not permitted.

4Di.m8 mDiinmgmchinargacctheraisraticcsteristics

Digital dimming value

255

225

200

DALI

175

DSI

150

125

100

75

50

25

0

0 10 20 30 40 50 60 70 80 90 100 Relative lighting level %

Dimming characteristics as seen by the human eye

6. Functions
6.1 Function: adjustable current
The output current of the LED Driver can be adjusted in a certain range. For adjustment there are three options available.
Option 1: DALI Adjustment is done by masterCONFIGURATOR (see masterCONFIGURATOR documentation).
Option 2: I-SELECT 2 By inserting a suitable resistor into the I-SELECT 2 interface, the current value can be adjusted. The relationship between output current and resistor value can be found in the chapter "Accessories I-SELECT 2 Plugs".
Please note that the resistor values for I-SELECT 2 are not compatible with I-SELECT (generation 1). Installation of an incorrect resistor may cause irreparable damage to the LED module(s).

5. Interfaces / communication
5.1 Control input (DA/N, DA/L)
Digital DALI signal or switchDIM can be wired on the same terminals (DA/N and DA/L).
The control input is non-polar for digital control signals (DALI, DSI). The control signal is not SELV. Control cable has to be installed in accordance to the requirements of low voltage installations. Different functions depending on each module.

Resistors for the main output current values can be ordered from Tridonic (see accessories).
Option 3: ready2mains Adjustment is done by the ready2mains programmer and the corresponding configuration software (see ready2mains documentation).
The priority for current adjustment methods is DALI (highest priority), I-SELECT 2, ready2mains (lowest priority).

Data sheet 04/20-LC562-8

Subject to change without notice. Information provided without guarantee.

www.tridonic.com

7

LED Driver INDUSTRY Linear Dimming

6.2 ready2mains ­ configuration

6.9 Constant light output (CLO)

The ready2mains interface can be used to configure the main parameters of LED Drivers via the mains wiring, such as LED output current, CLO and DC level. These parameters can be adjusted either via ready2mains-capable configuration software or directly via the ready2mains programmer (output current only).
6.3 ready2mains ­ dimming

The luminous flux of a LED decreases constantly over the life-time. The CLO function ensures that the emitted luminous flux remains stable. For that purpose the LED current will increase continuously over the LED life-time. In masterCONFIGURATOR it is possible to select a start value (in percent) and an expected life-time. The LED Driver adjusts the current afterwards automatically.

ready2mains allows for mains-based group dimming, controlled via the ready2mains protocol and appropriate dimming interfaces.
For details on the operation of ready2mains and its components see the relevant technical information.
6.4 Short-circuit behaviour
In case of a short-circuit at the LED output the LED output is switched off. After restart of the LED Driver the output will be activated again. The restart can either be done via mains reset or via interface (DALI, DSI, switchDIM, ready2mains).
6.5 No-load operation
The LED Driver will not be damaged in no-load operation. The output will be deactivated and is therefore free of voltage. If a LED load is connected the device has to be restarted before the output will be activated again.
6.6 Overload protection

6.10 Power-up/-down fading
The power-up/-down function offers the opportunity to modify the on-/off behavior. The time for fading on or off can be adjusted in a range of 0.2 to 16 seconds. According to this value, the device dims either from 0 % up to the power-on level or from the current set dim level down to 0 %. This feature applies while operating via switchDIM, ready2mains and when switching the mains voltage on or off. By factory default no fading time is set (= 0 seconds).
6.11 Light level in DC operation
The LED Driver is designed to operate on DC voltage and pulsed DC voltage. For a reliable operation, make sure that also in DC emergency operation the LED Driver is run within the specified conditions as stated in chapter "4.1 operating window".
Light output level in DC operation: programmable 1 ­ 100 % (EOFi = 0.13). Programming by DALI or ready2mains. In DC operation dimming mode can be activated.

If the output voltage range is exceeded the LED Driver turns off the LED output. After restart of the LED Driver the output will be activated again. The restart can either be done via mains reset or via interface (DALI, DSI, switchDIM, ready2mains).
6.7 Overtemperature protection

The voltage-dependent input current of Driver incl. LED module is depending on the used load.
The voltage-dependent no-load current of Driver (without or defect LED module) is for: AC: < 19 mA DC: < 2 mA

The LED Driver is protected against temporary thermal overheating. If the temperature limit is exceeded the output current of the LED module(s) is reduced. The temperature protection is activated above tc max. The activation temperature differs depending on the LED load. On DC operation this function is deactivated to fulfill emergency requirements.
6.8 corridorFUNCTION
The corridorFUNCTION can be programmed in two different ways. To program the corridorFUNCTION by means of software a DALI-USB interface is needed in combination with a DALI PS. The software can be the masterCONFIGURATOR. To activate the corridorFUNCTION without using software a voltage of 230V has to be applied for five minutes at the switchDIM connection. The unit will then switch automatically to the corridorFUNCTION.

6.12 Intelligent Voltage Guard
Intelligent Voltage Guard is the name of the electronic monitoring of the mains voltage. It immediately shows if the mains voltage rises above certain thresholds. Measures can then be taken quickly to prevent damage to the LED Driver.
· If the mains voltage rises above approx. 280Vrms (voltage depends on the LED Driver type), the LED light starts flashing on and off.
· To avoid a damage of the LED Driver the mains supply has to be switched off at this signal.

Note: If the corridorFUNCTION is wrongly activated in a switchDIM system (for example a switch is used instead of pushbutton), there is the option of installing a pushbutton and deactivating the corridorFUNCTION mode by five short pushes of the button within three seconds.

switchDIM and corridorFUNCTION are very simple tools for controlling gears with conventional pushbuttons or motion sensors. To ensure correct operation a sinusoidal mains voltage with a frequency of 50 Hz or 60 Hz is required at the control input. Special attention must be paid to achieving clear zero crossings. Serious mains faults may impair the operation of switchDIM and corridorFUNCTION.

Data sheet 04/20-LC562-8

Subject to change without notice. Information provided without guarantee.

www.tridonic.com

8

LED Driver INDUSTRY Linear Dimming

6.13 Software / programming
With appropriate software and an interface different functions can be activated and various parameters can be configured in the LED Driver. To do so, a DALI-USB or ready2mains programmer and the software (masterCONFIGURATOR) are required.
6.14 masterCONFIGURATOR
From version 2.8: For programming functions (CLO, I-SELECT 2, power-up fading, corridorFUNCTION) and device settings (fade time, ePowerOnLevel, DC level, etc.). For further information see masterCONFIGURATOR manual.
6.15 deviceCONFIGURATOR
PC (windows) based software application to transfer parameters into our drivers. Workflow optimised for the use in OEM production line. For further information see deviceCONFIGURATOR manual.

7. Miscellaneous

7.1 Insulation and electric strength testing of luminaires
Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production.
According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an insulation test with 500VDC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The insulation resistance must be at least 2M.
As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500VAC (or 1.414 x 1500VDC). To avoid damage to the electronic devices this test must not be conducted.

7.2 Conditions of use and storage

Humidity:

5% up to max. 85%, not condensed (max. 56 days/year at 85%)

Storage temperature: -40°C up to max. +80°C

The devices have to be acclimatised to the specified temperature range (ta) before they can be operated.

7.3 Maximum number of switching cycles All LED Driver are tested with 50,000 switching cycles. The actually achieved number of switching cycles is significantly higher.
7.4 Additional information Additional technical information at www.tridonic.com  Technical Data Guarantee conditions at www.tridonic.com  Services Life-time declarations are informative and represent no warranty claim. No warranty if device was opened.

Data sheet 04/20-LC562-8

Subject to change without notice. Information provided without guarantee.

www.tridonic.com

9


Adobe PDF Library 15.0 Adobe InDesign 15.0 (Windows)