PRODUCT BROCHURE
3VJ Series
Molded Case Circuit Breakers
MARCH 2021

3VJ SERIES
Molded Case Circuit Breakers
NEW!
THE EFFICIENT CHOICE
3VJ Molded Case Circuit Breakers with Thermal Magnetic Trip units offer the perfect solution whether in industrial applications, buildings, infrastructure or utilities. The 3VJ MCCBs are the efficient choice for cost effective power distribution. It ensures reliable protection of personnel and plants with simple functional features that maximize benefits for users in all segments. The 3VJ circuit breakers are available with rated operational currents ranging from 20 A to 630 A* and rated voltages up to 415 V. The ranges are available in 1, 2, 3 and 4-pole versions with 10, 18, 25, 36 and 55 kA breaking capacities. 3VJ MCCBs are delivered with 5 frame sizes. 3VJ MCCB conforms to these latest international standards; EN60947-2/2017, IS/IEC60947-2/2016 and pollution degree III.
*630A will launch in the next phase

KEY PRODUCT FEATURES

COMPACT
1 These MCCBs save space in enclosures & switchboards and reduces the overall size of the module.

RELIABLE & SAFE
2 Every piece of this MCCB is designed with the utmost quality for optimal performance. The 4 pole MCCB (100% rated) is perfect to operate in demanding applications.

FLEXIBLE
3 MCCBs come with common footprints from 10kA to 55kA breaking capacities and in addition no Neutral pole bias.

THE EFFICIENT CHOICE
4 This excellently crafted MCCB is coupled with user-friendly features
and cost-effective solutions for
power distribution.

THERMAL MAGNETIC TRIP UNIT
3VJ offers both FTFM and ATFM trip units for all ranges of components. It offers you N-conductor protection with 100% setting as all 4poles products.

Trip Units
Fixed Thermal Fixed Magnetic (FTFM) Adjustable Thermal Fixed Magnetic (ATFM)

Thermal Settings
In 0.8 ­ 1 In

Magnetic Settings
10 In 10 In

ACCESSORIES
In addition to the basic protection units of 3VJ MCCBs, it also offers accessory components to provide an efficient solution for all your power distribution requirements.

EXTERNAL
All important external accessories including Manual operators with position indicator, Mechanical interlocks, Spreaders, Toggle handle extension and Phase barriers as well as locking devices are available for all 3VJ frame sizes.

INTERNAL
All important internal accessories including Auxiliary and Alarm switches, Shunt trip and Undervoltage releases are available in categories of right and left cavity at different operating voltage levels.

TECHNICAL SPECIFICATIONS

COMING SOON

TYPE

3VJ10

3VJ11

Number of poles

1, 2, 3, 4

Frame Size

125 X

Rated operational current In A
at 45oC ambient temperature

20 ... 125

Rated operational voltage Ue 50/60 Hz AC Insulation voltage

V

415

V

800

Impulse voltage

kV

6

Suitable for Isolation

Yes

Utilization category, according to IEC60947-2

A

2, 3, 4 125
20 ... 125
415 1000
8 Yes A

Breaking capacity

A

B

N

N

S

M

Short-circuit breaking capacities Icu or Ics RMS value, according to IEC60947-2

Icu @ AC 415 V-50/60 Hz Ics @ AC 415 V-50/60 Hz Trip Units

kA

10

kA 100% of Icu

18

25

75% of Icu

Fixed Thermal Fixed Magnetic

FTFM

Adjustable Thermal Fixed Magnetic Neutral Protection in 4P MCCB

ATFM

100%

Endurance

Mechanical Electrical 415V AC

15000 3000

Connection Technology

25

36

55

75% of Icu

100%
15000 5000

Standard Connection Technology

Screw Terminal

Overall Dimensions

Width x Depth x Height (mm)

1p

2p / 3p / 4p

32.6 x 61.8 80 (2p/3p) / 103.5(4p)

x 118

x 68 x 126

2p / 3p / 4p 92 (2p/3p) / 122.2(4p)
x 85 x 150

B 18
1p 46 x 81.5
x 150

3VJ12 1, 2, 3, 4
250
160 ... 250

3VJ13 3, 4 400
320 ... 400

415
1000 8 Yes
A

415
1000 8 Yes
A

N

S

M

N

S

M

25

36

75% of Icu

55

25

36

55

75% of Icu

100%
15000 5000

100%
10000 3000

Screw Terminal

2p / 3p / 4p 107.5 (2p/3p) / 142.5 (4p)
x 85 x 166

3p / 4p 150 (3p) / 198 (4p)
x 104 x 260

3VJ14 3, 4 630
500 ... 630

415
1000 8 Yes
A

S

M

36

55

75% of Icu

100%
10000 3000

3p / 4p 150 (3p) / 198 (4p)
x 104 x 260

PRODUCT DIMENSIONS
3VJ10

3VJ11

1 Pole

2 Pole

100

92

30

30

22

8.5

3 Pole

130

122

30

30

30

22

8.5

Depth
115 90 85 81 24 2.5

212 190 150 134 51 251 251 212 190 150 134 210

3VJ12

3 Pole

17

39

39

78

116

107.5

35

35

25

11

14

14

36

36

36

4 Pole

151 142.5

35

35

35

25

11

Depth

114

90

85

81

3

26

225 203 166 147 50 267 225 203 166 147 50.4 267 226

3VJ13

3 Pole

20.5 45.5

45.5

41.04

520.9 473.55

151.54

151.54

126.28

4 Pole

17

17

42

42

42

41.04

151.54

708.75 625
151.54

151.54

126.28

Depth

467 366.21 348 328.33
15.78

39.5

1152 1013 820.82 729 313 1448 1152 1013 820.82 729 316 1424.52 1169

3 Pole All dimensions are in mm

71.03 197.31

197.31

4 Pole

69.45

64.72

195.73

191

195.73

Depth

PRODUCT SELECTION GUIDE

The order number is systematically structured and provides information about the most important features of the 3VJ Molded Case Circuit Breaker.

Breaker type:

3VJ 1 1

2 25 ­ 6 DA 3

Frame size:

3VJ10

16 ­ 125

0

3VJ11

16 ­ 125

1

3VJ12

160 ­ 250

2

3VJ13

320 ­ 400

3

3VJ14

500 ­ 630

4

Rated current 3VJ10

3VJ11

3VJ12

3VJ13 3VJ14

in A:

In = 20

In = 20

02

In = 25

In = 25

92

In = 32

In = 32

03

In = 40

In = 40

04

In = 50

In = 50

05

In = 63

In = 63

06

In = 80

In = 80

08

In = 100

In = 100

10

In = 125

In = 125

12

In = 160

16

In = 200

20

In = 250

25

In = 320

32

In = 400

40

In = 500

50

In = 630

63

Breaking

3VJ10

3VJ11

3VJ12*

3VJ13 3VJ14

capacity @ 415 V:

1P | 2P | 3P | 4P 2P | 3P | 4P 2P | 3P | 4P 3P | 4P 3P | 4P 10/10

Icu / Ics

18/12 25/18

25/18

18/12 25/18

25/18

36/27

36/27

36/27 36/27

55/41

55/41

55/41 55/41

Trip unit: TM

FTFM ATFM

1P | 2P | 3P 4P 3P 4P

Pole:

1-pole

2-pole

3-pole

4-pole

Screw connection:

Internal accessory:

0 1 3 5 7
DA EA DB EB
1 2 3 4

6 ­ 0AA0
2 W/O

*3VJ12 is also available in 1-Pole only 160 A and 18,25 kA

PRODUCT SELECTION
1 Pole Thermal Magnetic Trip Unit Fixed Thermal Fixed Magnetic (FTFM) 415VAC + 50Hz

3VJ10

Frame Size

Nominal Current

/n

A

20

25

32

40

3VJ10

50

63

80

100

125

25

32

40

50 3VJ11
63

80

100

125

3VJ12

160

Overload Protection
L
/r A
20 25 32 40 50 63 80 100 125 25 32 40 50 63 80 100 125 160

Short-circuit Protection
I
/i A
500 500 550 550 600 850 850 1250 1250 500 600 600 600 630 800 1000 1250 1600

/cu = 10kA at 415V
3VJ1002-0DA12-0AA0 3VJ1092-0DA12-0AA0 3VJ1003-0DA12-0AA0 3VJ1004-0DA12-0AA0 3VJ1005-0DA12-0AA0 3VJ1006-0DA12-0AA0 3VJ1008-0DA12-0AA0 3VJ1010-0DA12-0AA0 3VJ1012-0DA12-0AA0
----------

3VJ11

3VJ12

Order Number

/cu = 18kA at 415V
3VJ1002-1DA12-0AA0 3VJ1092-1DA12-0AA0 3VJ1003-1DA12-0AA0 3VJ1004-1DA12-0AA0 3VJ1005-1DA12-0AA0 3VJ1006-1DA12-0AA0 3VJ1008-1DA12-0AA0 3VJ1010-1DA12-0AA0 3VJ1012-1DA12-0AA0
--------3VJ1216-1DA12-0AA0

/cu = 25kA at 415V
3VJ1002-3DA12-0AA0 3VJ1092-3DA12-0AA0 3VJ1003-3DA12-0AA0 3VJ1004-3DA12-0AA0 3VJ1005-3DA12-0AA0 3VJ1006-3DA12-0AA0 3VJ1008-3DA12-0AA0 3VJ1010-3DA12-0AA0 3VJ1012-3DA12-0AA0
--------3VJ1216-3DA12-0AA0

2 Pole Thermal Magnetic Trip Unit Fixed Thermal Fixed Magnetic (FTFM)
415VAC + 50Hz

3VJ10

3VJ11

3VJ12

Frame Nominal Overload Size Current Protection
L

Shortcircuit Protection
I

Order Number

/n

/r

A

A

20

20

25

25

32

32

40

40

3VJ10

50

50

63

63

80

80

100

100

125

125

25

25

32

32

40

40

50

50

3VJ11

63

63

80

80

100

100

125

125

160

160

3VJ12

200

200

250

250

/i A
500 500 550 550 600 850 850
1250 1250 500 550 550 600 850 850 1,250 1,250 1600 2000 2500

/cu = 10kA at 415V
3VJ1002-0DA22-0AA0

/cu = 18kA at 415V
3VJ1002-1DA22-0AA0

/cu = 25kA at 415V
3VJ1002-3DA22-0AA0

3VJ1092-0DA22-0AA0 3VJ1092-1DA22-0AA0 3VJ1092-3DA22-0AA0

3VJ1003-0DA22-0AA0 3VJ1003-1DA22-0AA0 3VJ1003-3DA22-0AA0

3VJ1004-0DA22-0AA0 3VJ1004-1DA22-0AA0 3VJ1004-3DA22-0AA0

3VJ1005-0DA22-0AA0 3VJ1005-1DA22-0AA0 3VJ1005-3DA22-0AA0

3VJ1006-0DA22-0AA0 3VJ1006-1DA22-0AA0 3VJ1006-3DA22-0AA0

3VJ1008-0DA22-0AA0 3VJ1008-1DA22-0AA0 3VJ1008-3DA22-0AA0

/cu = 36kA at 415V
-------
--

/cu = 55kA at 415V
-------
--

3VJ1010-0DA22-0AA0 3VJ1010-1DA22-0AA0 3VJ1010-3DA22-0AA0

--

--

3VJ1012-0DA22-0AA0 3VJ1012-1DA22-0AA0 3VJ1012-3DA22-0AA0

--

--

--

--

--

3VJ1192-5DA22-0AA0 3VJ1192-7DA22-0AA0

--

--

--

3VJ1103-5DA22-0AA0 3VJ1103-7DA22-0AA0

--

--

--

3VJ1104-5DA22-0AA0 3VJ1104-7DA22-0AA0

--

--

--

3VJ1105-5DA22-0AA0 3VJ1105-7DA22-0AA0

--

--

--

3VJ1106-5DA22-0AA0 3VJ1106-7DA22-0AA0

--

--

--

3VJ1108-5DA22-0AA0 3VJ1108-7DA22-0AA0

--

--

--

3VJ1110-5DA22-0AA0 3VJ1110-7DA22-0AA0

--

--

--

3VJ1112-5DA22-0AA0 3VJ1112-7DA22-0AA0

3VJ1216-1DA22-0AA0 3VJ1216-3DA22-0AA0 3VJ1216-5DA22-0AA0 3VJ1216-7DA22-0AA0

3VJ1220-1DA22-0AA0 3VJ1220-3DA22-0AA0 3VJ1220-5DA22-0AA0 3VJ1220-7DA22-0AA0

3VJ1225-1DA22-0AA0 3VJ1225-3DA22-0AA0 3VJ1225-5DA22-0AA0 3VJ1225-7DA22-0AA0

PRODUCT SELECTION

3 Pole Thermal Magnetic Trip Unit Fixed Thermal Fixed Magnetic (FTFM)
415VAC + 50Hz

3VJ10 3VJ11

3VJ12

3VJ13

3VJ14

Frame Size

Nominal Current
/n A

Overload Protection
L
/r A

Shortcircuit Protection
I
/i
A

/cu = 10kA at 415V

/cu = 18kA at 415V

Order Number /cu = 25kA at 415V

/cu = 36kA at 415V /cu = 55kA at 415V

20

25

32 40

3VJ10

50

63

80

100

125

25

32

40

50 3VJ11
63

80

100 125 160

3VJ12

200

250

320 3VJ13
400

500 3VJ14
630

20 25 32 40 50 63 80 100 125 25 32 40 50 63 80 100 125 160 200 250 320 400 500 630

500 500 550 550 600 850 850 1250 1250 550 600 600 600 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300

3VJ1002-0DA32-0AA0 3VJ1002-1DA32-0AA0 3VJ1002-3DA32-0AA0

--

--

3VJ1092-0DA32-0AA0 3VJ1092-1DA32-0AA0 3VJ1092-3DA32-0AA0

--

--

3VJ1003-0DA32-0AA0 3VJ1003-1DA32-0AA0 3VJ1003-3DA32-0AA0

--

--

3VJ1004-0DA32-0AA0 3VJ1004-1DA32-0AA0 3VJ1004-3DA32-0AA0

--

--

3VJ1005-0DA32-0AA0 3VJ1005-1DA32-0AA0 3VJ1005-3DA32-0AA0

--

--

3VJ1006-0DA32-0AA0 3VJ1006-1DA32-0AA0 3VJ1006-3DA32-0AA0

--

--

3VJ1008-0DA32-0AA0 3VJ1008-1DA32-0AA0 3VJ1008-3DA32-0AA0

--

--

3VJ1010-0DA32-0AA0 3VJ1012-0DA32-0AA0
---

3VJ1010-1DA32-0AA0 3VJ1012-1DA32-0AA0
---

3VJ1010-3DA32-0AA0 3VJ1012-3DA32-0AA0
---

--3VJ1192-5DA32-0AA0 3VJ1103-5DA32-0AA0

--3VJ1192-7DA32-0AA0 3VJ1103-7DA32-0AA0

--

--

--

3VJ1104-5DA32-0AA0 3VJ1104-7DA32-0AA0

--

--

--

3VJ1105-5DA32-0AA0 3VJ1105-7DA32-0AA0

--

--

--

3VJ1106-5DA32-0AA0 3VJ1106-7DA32-0AA0

--

--

--

3VJ1108-5DA32-0AA0 3VJ1108-7DA32-0AA0

--

--

--

3VJ1110-5DA32-0AA0 3VJ1110-7DA32-0AA0

--

--

--

3VJ1112-5DA32-0AA0 3VJ1112-7DA32-0AA0

--

3VJ1216-1DA32-0AA0 3VJ1216-3DA32-0AA0 3VJ1216-5DA32-0AA0 3VJ1216-7DA32-0AA0

--

3VJ1220-1DA32-0AA0 3VJ1220-3DA32-0AA0 3VJ1220-5DA32-0AA0 3VJ1220-7DA32-0AA0

--

3VJ1225-1DA32-0AA0 3VJ1225-3DA32-0AA0 3VJ1225-5DA32-0AA0 3VJ1225-7DA32-0AA0

--

--

3VJ1332-3DA32-0AA0 3VJ1332-5DA32-0AA0 3VJ1332-7DA32-0AA0

--

--

3VJ1340-3DA32-0AA0 3VJ1340-5DA32-0AA0 3VJ1340-7DA32-0AA0

--

--

--

3VJ1450-5DA32-0AA0* 3VJ1450-7DA32-0AA0*

--

--

--

3VJ1463-5DA32-0AA0* 3VJ1463-7DA32-0AA0*

*Coming soon

3 Pole Thermal Magnetic Trip Unit Adjustable Thermal Fixed Magnetic (ATFM)
415VAC + 50Hz

3VJ10 3VJ11

3VJ12

3VJ13

3VJ14

Frame Size

Nominal Current

Overload Protection
L

Shortcircuit Protection

/n

/r

A

A

I

/i

/cu = 10kA at 415V

A

20

500

3VJ1002-0DB32-0AA0

25

500

3VJ1092-0DB32-0AA0

32

550

3VJ1003-0DB32-0AA0

40

3VJ10

50

0.8 ­ 1 /n

550

3VJ1004-0DB32-0AA0

600

3VJ1005-0DB32-0AA0

63

850

3VJ1006-0DB32-0AA0

80

850

3VJ1008-0DB32-0AA0

100

1250

3VJ1010-0DB32-0AA0

125

1250

3VJ1012-0DB32-0AA0

25

550

32

600

40

600

50

600

3VJ11

0.8 ­ 1 /n

63

630

80

800

100

1000

125

1250

160

1600

3VJ12

200

250

0.8 ­ 1 /n

2000 2500

320
3VJ13 400

0.8 ­ 1 /n

3200 4000

500
3VJ14 630

0.8 ­ 1 /n

5000 6300

Order Number

/cu = 18kA at 415V

/cu = 25kA at 415V /cu = 36kA at 415V /cu = 55kA at 415V

3VJ1002-1DB32-0AA0 3VJ1092-1DB32-0AA0 3VJ1003-1DB32-0AA0 3VJ1004-1DB32-0AA0 3VJ1005-1DB32-0AA0 3VJ1006-1DB32-0AA0 3VJ1008-1DB32-0AA0 3VJ1010-1DB32-0AA0 3VJ1012-1DB32-0AA0
-------3VJ1216-1DB32-0AA0 3VJ1220-1DB32-0AA0 3VJ1225-1DB32-0AA0

3VJ1002-3DB32-0AA0

--

--

3VJ1092-3DB32-0AA0

--

--

3VJ1003-3DB32-0AA0

--

--

3VJ1004-3DB32-0AA0

--

--

3VJ1005-3DB32-0AA0

--

--

3VJ1006-3DB32-0AA0

--

--

3VJ1008-3DB32-0AA0

--

--

3VJ1010-3DB32-0AA0 3VJ1012-3DB32-0AA0

--3VJ1192-5DB32-0AA0

--3VJ1192-7DB32-0AA0

--

3VJ1103-5DB32-0AA0 3VJ1103-7DB32-0AA0

--

3VJ1104-5DB32-0AA0 3VJ1104-7DB32-0AA0

--

3VJ1105-5DB32-0AA0 3VJ1105-7DB32-0AA0

--

3VJ1106-5DB32-0AA0 3VJ1106-7DB32-0AA0

--

3VJ1108-5DB32-0AA0 3VJ1108-7DB32-0AA0

--3VJ1216-3DB32-0AA0

3VJ1110-5DB32-0AA0 3VJ1112-5DB32-0AA0 3VJ1216-5DB32-0AA0

3VJ1110-7DB32-0AA0 3VJ1112-7DB32-0AA0 3VJ1216-7DB32-0AA0

3VJ1220-3DB32-0AA0 3VJ1220-5DB32-0AA0 3VJ1220-7DB32-0AA0

3VJ1225-3DB32-0AA0

3VJ1225-5DB32-0AA0 3VJ1225-7DB32-0AA0

3VJ1332-3DB32-0AA0

3VJ1332-5DB32-0AA0 3VJ1332-7DB32-0AA0

3VJ1340-3DB32-0AA0 3VJ1340-5DB32-0AA0 3VJ1340-7DB32-0AA0

3VJ1450-5DB32-0AA0* 3VJ1450-7DB32-0AA0*

3VJ1463-5DB32-0AA0* 3VJ1463-7DB32-0AA0*

*Coming soon

PRODUCT SELECTION

4 Pole Thermal Magnetic Trip Unit Fixed Thermal Fixed Magnetic (FTFM)
415VAC + 50Hz

3VJ10 3VJ11

3VJ12

3VJ13

3VJ14

Frame Size

Nominal Current
/n A

Overload Protection
L
/r A

Shortcircuit Protection
I
/i
A

/cu = 10kA at 415V

/cu = 18kA at 415V

Order Number /cu = 25kA at 415V

/cu = 36kA at 415V /cu = 55kA at 415V

20

25

32 40

3VJ10

50

63

80

100

125

25

32

40

50 3VJ11
63

80

100 125 160

3VJ12

200

250

320 3VJ13
400

500 3VJ14
630

20 25 32 40 50 63 80 100 125 25 32 40 50 63 80 100 125 160 200 250 320 400 500 630

500 500 550 550 600 850 850 1250 1250 550 600 600 600 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300

3VJ1002-0DA42-0AA0 3VJ1002-1DA42-0AA0 3VJ1002-3DA42-0AA0

--

--

3VJ1092-0DA42-0AA0 3VJ1092-1DA42-0AA0 3VJ1092-3DA42-0AA0

--

--

3VJ1003-0DA42-0AA0 3VJ1003-1DA42-0AA0 3VJ1003-3DA42-0AA0

--

--

3VJ1004-0DA42-0AA0 3VJ1004-1DA42-0AA0 3VJ1004-3DA42-0AA0

--

--

3VJ1005-0DA42-0AA0 3VJ1005-1DA42-0AA0 3VJ1005-3DA42-0AA0

--

--

3VJ1006-0DA42-0AA0 3VJ1006-1DA42-0AA0 3VJ1006-3DA42-0AA0

--

--

3VJ1008-0DA42-0AA0 3VJ1008-1DA42-0AA0 3VJ1008-3DA42-0AA0

--

--

3VJ1010-0DA42-0AA0 3VJ1012-0DA42-0AA0
---

3VJ1010-1DA42-0AA0 3VJ1012-1DA42-0AA0
---

3VJ1010-3DA42-0AA0 3VJ1012-3DA42-0AA0
---

--3VJ1192-5DA42-0AA0 3VJ1103-5DA42-0AA0

--3VJ1192-7DA42-0AA0 3VJ1103-7DA42-0AA0

--

--

--

3VJ1104-5DA42-0AA0 3VJ1104-7DA42-0AA0

--

--

--

3VJ1105-5DA42-0AA0 3VJ1105-7DA42-0AA0

--

--

--

3VJ1106-5DA42-0AA0 3VJ1106-7DA42-0AA0

--

--

--

3VJ1108-5DA42-0AA0 3VJ1108-7DA42-0AA0

--

--

--

3VJ1110-5DA42-0AA0 3VJ1110-7DA42-0AA0

--

--

--

3VJ1112-5DA42-0AA0 3VJ1112-7DA42-0AA0

--

3VJ1216-1DA42-0AA0 3VJ1216-3DA42-0AA0 3VJ1216-5DA42-0AA0 3VJ1216-7DA42-0AA0

--

3VJ1220-1DA42-0AA0 3VJ1220-3DA42-0AA0 3VJ1220-5DA42-0AA0 3VJ1220-7DA42-0AA0

--

3VJ1225-1DA42-0AA0 3VJ1225-3DA42-0AA0 3VJ1225-5DA42-0AA0 3VJ1225-7DA42-0AA0

--

--

3VJ1332-3DA42-0AA0 3VJ1332-5DA42-0AA0 3VJ1332-7DA42-0AA0

--

--

3VJ1340-3DA42-0AA0 3VJ1340-5DA42-0AA0 3VJ1340-7DA42-0AA0

--

--

--

3VJ1450-5DA42-0AA0* 3VJ1450-7DA42-0AA0*

--

--

--

3VJ1463-5DA42-0AA0* 3VJ1463-7DA42-0AA0*

*Coming soon

4 Pole Thermal Magnetic Trip Unit Adjustable Thermal Fixed Magnetic (ATFM)
415VAC + 50Hz

3VJ10 3VJ11

3VJ12

3VJ13

3VJ14

Frame Size

Nominal Current

Overload Protection
L

Shortcircuit Protection

/n

/r

A

A

I

/i

/cu = 10kA at 415V

A

20

500

3VJ1002-0DB42-0AA0

25

500

3VJ1092-0DB42-0AA0

32

550

3VJ1003-0DB42-0AA0

40

3VJ10

50

0.8 ­ 1 /n

550 600

3VJ1004-0DB42-0AA0 3VJ1005-0DB42-0AA0

63

850

3VJ1006-0DB42-0AA0

80

850

3VJ1008-0DB42-0AA0

100

1250

3VJ1010-0DB42-0AA0

125

1250

3VJ1012-0DB42-0AA0

25

550

32

600

40

600

50

600

3VJ11

0.8 ­ 1 /n

63

630

80

800

100

125

160

3VJ12

200

250

0.8 ­ 1 /n

1000 1250 1600 2000 2500

320
3VJ13 400

0.8 ­ 1 /n

3200 4000

500
3VJ14 630

0.8 ­ 1 /n

5000 6300

Order Number

/cu = 18kA at 415V

/cu = 25kA at 415V /cu = 36kA at 415V /cu = 55kA at 415V

3VJ1002-1DB42-0AA0 3VJ1092-1DB42-0AA0 3VJ1003-1DB42-0AA0 3VJ1004-1DB42-0AA0 3VJ1005-1DB42-0AA0 3VJ1006-1DB42-0AA0 3VJ1008-1DB42-0AA0 3VJ1010-1DB42-0AA0 3VJ1012-1DB42-0AA0
-------3VJ1216-1DB42-0AA0 3VJ1220-1DB42-0AA0 3VJ1225-1DB42-0AA0

3VJ1002-3DB42-0AA0

--

--

3VJ1092-3DB42-0AA0

--

--

3VJ1003-3DB42-0AA0

--

--

3VJ1004-3DB42-0AA0

--

--

3VJ1005-3DB42-0AA0

--

--

3VJ1006-3DB42-0AA0

--

--

3VJ1008-3DB42-0AA0

--

--

3VJ1010-3DB42-0AA0 3VJ1012-3DB42-0AA0

--3VJ1192-5DB42-0AA0

--3VJ1192-7DB42-0AA0

--

3VJ1103-5DB42-0AA0 3VJ1103-7DB42-0AA0

--

3VJ1104-5DB42-0AA0 3VJ1104-7DB42-0AA0

--

3VJ1105-5DB42-0AA0 3VJ1105-7DB42-0AA0

--

3VJ1106-5DB42-0AA0 3VJ1106-7DB42-0AA0

--

3VJ1108-5DB42-0AA0 3VJ1108-7DB42-0AA0

--3VJ1216-3DB42-0AA0

3VJ1110-5DB42-0AA0 3VJ1112-5DB42-0AA0 3VJ1216-5DB42-0AA0

3VJ1110-7DB42-0AA0 3VJ1112-7DB42-0AA0 3VJ1216-7D42-0AA0

3VJ1220-3DB42-0AA0 3VJ1220-5DB42-0AA0 3VJ1220-7DB42-0AA0

3VJ1225-3DB42-0AA0

3VJ1225-5DB42-0AA0 3VJ1225-7DB42-0AA0

3VJ1332-3DB42-0AA0

3VJ1332-5DB42-0AA0 3VJ1332-7DB42-0AA0

3VJ1340-3DB42-0AA0 3VJ1340-5DB42-0AA0 3VJ1340-7DB42-0AA0

3VJ1450-5DB42-0AA0* 3VJ1450-7DB42-0AA0*

3VJ1463-5DB42-0AA0* 3VJ1463-7DB42-0AA0*

*Coming soon

PRODUCT DETAILS

EXTERNAL ACCESSORIES

ACCESSORIES

3VJ10

3VJ11

FRAME SIZE 3VJ12

Extended Door Mounted Rotary Operator (including 8UC handle)1

3VJ13

3VJ14

3VJ9018-0HD11 3VJ9118-0HD11

3VJ9218-0HD11

3VJ9417-0HD11 3VJ9417-0HD11

Straight Terminals2

3VJ9011-0EC00

--

3VJ9211-0EC00

--

--

Spreader Terminals3
2P 3P 4P
Phase Barriers4

3VJ9012-0ED00 3VJ9013-0ED00 3VJ9014-0ED00

3VJ9112-0ED00 3VJ9113-0ED00 3VJ9114-0ED00

3VJ9212-0ED00 3VJ9213-0ED00 3VJ9214-0ED00

--

--

3VJ9313-0ED00 3VJ9413-0ED00* 3VJ9314-0ED00 3VJ9414-0ED00*

3VJ9018-0CA00 3VJ9218-0CA00

3VJ9218-0CA00 3VJ9018-0CA00 3VJ9018-0CA00

Terminal Covers5
1P 3VJ9011-0CJ10 3P 3VJ9016-0CJ30 4P 3VJ9014-0CJ40
Locking device

-3VJ9116-0CJ30 3VJ9114-0CJ40

3VJ9211-0CJ10 3VJ9216-0CJ30 3VJ9214-0CJ40

-3VJ9413-0CJ30 3VJ9414-0CJ40

-3VJ9413-0CJ30 3VJ9414-0CJ40

--

Mechanical Interlock (2 pieces)

3P

--

4P

--

Toggle handle extension

3VJ9118-0LM10

3VJ9218-0LM10 3VJ9317-0LM10 3VJ9317-0LM10

3VJ9116-0VM10 3VJ9114-0VM10

3VJ9216-0VM10 3VJ9214-0VM10

3VJ9313-0VM10 3VJ9314-0VM10

3VJ9313-0VM10 3VJ9314-0VM10

--

--

--

3VJ9417-0DH10 3VJ9417-0DH10

1) 1 set contains rotary mechanism, coupler, shaft and 8UC handle. 2) Straight Terminals: 1 set = 2 pieces.3) Spreader Terminal: 1 set = 3 pieces for 3-pole and 4pieces in case of 4-pole. 4) Available as a standard: 1 set contains 2 phase barriers. 5) Available as a standard: 1 set contains 2 terminal covers (top & bottom).

INTERNAL ACCESSORIES

ACCESSORIES
AUX Auxiliary Switch

3VJ10

3VJ11

FRAME SIZE 3VJ12

L

3VJ9018-0AN11 3VJ9218-0AN11 3VJ9218-0AN11

3VJ13

3VJ14

AL Alarm Switch

R

3VJ9018-0AN21 3VJ9218-0AN21 3VJ9218-0AN21

L

3VJ9018-0AA11 3VJ9118-0AA11 3VJ9218-0AA11

R

--

3VJ9118-0AA21 3VJ9218-0AA21

AUX + AL Auxiliary Switch

L

3VJ9018-0AD11 3VJ9118-0AD11 3VJ9218-0AD11 3VJ9417-0AD11 3VJ9417-0AD11

R

--

STL Shunt Trip UVR Under Voltage Release

24V DC 48V DC 110V DC 110V AC 220V AC 415V AC

24V DC

48V DC --
220V AC
415V AC

3VJ9118-0AD21 3VJ9218-0AD21 3VJ9417-0AD21 3VJ9417-0AD21

3VJ9218-0ST11 3VJ9218-0ST12 3VJ9218-0ST15 3VJ9218-0ST35 3VJ9218-0ST36 3VJ9218-0ST37
3VJ9218-0UV11 3VJ9218-0UV12 3VJ9218-0UV36 3VJ9218-0UV37

3VJ9417-0ST21 3VJ9417-0ST22 3VJ9417-0ST25 3VJ9417-0ST25 3VJ9417-0ST36 3VJ9417-0ST37
3VJ9417-0UV11* 3VJ9417-0UV12* 3VJ9417-0UV36 3VJ9417-0UV37

3VJ Series Product Brochure 2021

Siemens Limited
Smart Infrastructure Electrical Products (EP)

Ho Chi Minh City Deutsches Haus, 7th Floor 33 Le Duan Street, District 1 Ho Chi Minh City, Vietnam Tel.: + 84 (28) 3825 1900 Fax: + 84 (28) 3825 1580

Hanoi Ocean Park Building, 9th Floor 1 Dao Duy Anh Street, Dong Da District, Hanoi, Vietnam Tel.: + 84 (24) 3577 6688 Fax: + 84 (24) 3577 6699

info.vn@siemens.com

www.siemens.com.vn www.facebook.com/Siemens.Vietnam

Attach business card here
Subject to changes and errors. The information given in this document only contains general descriptions and/ or performance features which may not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the concluded contract. © Siemens 2021
Visit Industry Mall


Adobe PDF Library 15.0 Adobe InDesign 16.0 (Windows)