GM67 Bar Code Reader Module User Manual
Hangzhou Grow Technology Co., Ltd. V1.1 Dec.2019

Catalog
1 Introduction of Module............................................................................................................................................1 1.1 Introduction................................................................................................................................................... 1 1.2 Technical Specification............................................................................................................................... 1 1.3 Dimension (mm)...........................................................................................................................................2 1.4 Scan Head Definition.................................................................................................................................. 3 1.5 Circuit Board Communication Interface...................................................................................................4 1.6 Scanning Area Map..................................................................................................................................... 5 1.7 Readable Barcode Type............................................................................................................................. 5
2 Factory Mode Information......................................................................................................................................7 2.1 Factory Default Configuration....................................................................................................................7 2.2 Setup Code...................................................................................................................................................7 2.3 Allow Send the Setup Code Information..................................................................................................7
3 Communication Interface.......................................................................................................................................8 3.1 Serial Port..................................................................................................................................................... 8 3.1.1 Baud rate........................................................................................................................................... 8 3.1.2 Parity Bit.............................................................................................................................................9 3.1.3 Stop Bit...............................................................................................................................................9 3.2 USB KBW......................................................................................................................................................9 3.3 USB COM Keyboard................................................................................................................................... 9
4 Read Mode.............................................................................................................................................................10 4.1 Manual Mode..............................................................................................................................................10 4.1.1 Button Holding Mode.....................................................................................................................10 4.1.2 Button Trigger Mode...................................................................................................................... 10 4.2 Continuous Mode...................................................................................................................................... 10 4.2.1 Break Time Settlement.................................................................................................................. 11 4.3 Induction Mode...........................................................................................................................................11 4.3.1 Stable Induction Time.................................................................................................................... 11 4.3.2 Sensitivity Rating Setting..............................................................................................................12 4.4 Host Mode.................................................................................................................................................. 12 4.5 Single Scan Time.......................................................................................................................................12
I

4.5.1 Single Scan Time Quickly Set Up............................................................................................... 13 4.6 Time Interval For The Same Code Read.............................................................................................. 13
4.6.1 Same Code Quickly Set Up......................................................................................................... 13 5 Lighting and Collimate......................................................................................................................................... 14
5.1 Lighting........................................................................................................................................................14 5.2 Collimation.................................................................................................................................................. 14 6 Prompts.................................................................................................................................................................. 15 6.1 Keyboard.....................................................................................................................................................15
6.1.1 Keyboard Settlement.....................................................................................................................15 6.1.2 Keyboard Type............................................................................................................................... 16 6.1.3 Keyboard Output Character Time Interval.................................................................................17 6.1.4 ASCII Control Character Output Mode Selection..................................................................... 17 6.2 Prompts Tone............................................................................................................................................. 18 6.2.1 Buzzer Type.................................................................................................................................... 18 6.2.2 Silent Mode..................................................................................................................................... 18 6.2.3 Volume Level.................................................................................................................................. 18 6.2.4 Decoding Successful Prompt Tone.............................................................................................18 6.2.5 Starting Up Prompt........................................................................................................................ 18 6.2.6 Setup Code Prompt....................................................................................................................... 19 6.3 Decoding Successful Prompt Light........................................................................................................ 19 6.4 Decoding Prompt Working Mode............................................................................................................19 6.5 Decoding Prompt.......................................................................................................................................19 6.6 Keyboard Output Force Letter Case Conversion................................................................................ 20 6.7 Data Code Format.....................................................................................................................................20 7 Data Edition........................................................................................................................................................... 21 7.1 CODE ID..................................................................................................................................................... 21 7.2 Terminator Character................................................................................................................................ 21 7.3 Add Prefix and Suffix.................................................................................................................................22 7.3.1 Prefix................................................................................................................................................ 22 7.3.2 Suffix(Similar to a prefix, you can add a newline to suffix if you need a newline).............. 22 7.3.3 Prefix Suffix Take Effect................................................................................................................ 23 7.4 Hide Header, Middle and Tail Characters..............................................................................................23 7.4.1 Hide Header Characters............................................................................................................... 23

II

www.hzgrow.com

7.4.2 Hide Middle Characters................................................................................................................ 24 7.4.3 Hide Tail Characters...................................................................................................................... 25 7.5 Set STX and ETX...................................................................................................................................... 25 8 All Types of Bar Code Can be Decoded........................................................................................................... 26 8.1 1D Code Global Enable Switch...............................................................................................................26 8.2 2D Code Global Enable Switch...............................................................................................................26 8.3 Forward and backward reading of 1D Code.........................................................................................26 8.4 UPC-A......................................................................................................................................................... 26 8.4.1 UPC-A.............................................................................................................................................. 26 8.4.2 UPC-A Leading Code.................................................................................................................... 27 8.4.3 UPC-A Check Bit............................................................................................................................27 8.5 UPC-A Extra Code.................................................................................................................................... 27 8.5.1 UPC-A 2-bit Extra Code................................................................................................................27 8.5.2 UPC-A 5-bit Extra Code................................................................................................................27 8.5.3 UPC-A Extra Code Must be Identified........................................................................................27 8.6 UPC-E......................................................................................................................................................... 28 8.6.1 UPC-E.............................................................................................................................................. 28 8.6.2 UPC-E Leading Code....................................................................................................................28 8.6.3 UPC-E Check Bit............................................................................................................................28 8.7 UPC-E Extra Code.................................................................................................................................... 28 8.7.1 UPC-E 2-bit Extra Code................................................................................................................28 8.7.2 UPC-E 5-bit Extra Code................................................................................................................29 8.7.3 UPC-E Extra Code Must be Identified........................................................................................29 8.8 UPC-E Turn UPC-A...................................................................................................................................29 8.9 UPC-A Turn EAN-13................................................................................................................................. 29 8.10 UPC-E1..................................................................................................................................................... 29 8.11 EAN-8........................................................................................................................................................ 30 8.11.1 EAN-8.............................................................................................................................................30 8.11.2 EAN-8 Check Bit.......................................................................................................................... 30 8.12 EAN-8 Extra Code...................................................................................................................................30 8.12.1 EAN-8 2-bit Extra Code.............................................................................................................. 30 8.12.2 EAN-8 5-bit Extra Code.............................................................................................................. 30 8.12.3 EAN-8 Extra Code Must be Identified...................................................................................... 31

III

www.hzgrow.com

8.13 EAN-13......................................................................................................................................................31 8.13.1 EAN-13.......................................................................................................................................... 31 8.13.2 EAN-13 Check Bit........................................................................................................................31
8.14 Bookland EAN(ISBN)............................................................................................................................. 31 8.15 EAN-13 Extra Code................................................................................................................................ 32
8.15.1 EAN-13 2-bit Extra Code............................................................................................................32 8.15.2 EAN-13 5-bit Extra Code............................................................................................................32 8.15.3 EAN-13 Extra Code Must be Identified....................................................................................32 8.16 CODE 128................................................................................................................................................ 32 8.17 GS1-128(UCC/EAN-128).......................................................................................................................33 8.18 ISSN.......................................................................................................................................................... 33 8.19 Interleaved 2 of 5.....................................................................................................................................33 8.19.1 I 2 of 5............................................................................................................................................ 33 8.19.2 Interleaved 2 of 5 Identify Length............................................................................................. 33 8.19.3 Interleaved 2 of 5 Check Bit Verification..................................................................................34 8.19.4 Interleaved 2 of 5 Check Bit Transmission..............................................................................34 8.20 Matrix 2 of 5..............................................................................................................................................34 8.20.1 Matrix 2 of 5.................................................................................................................................. 34 8.20.2 Matrix 2 of 5 Identify Length...................................................................................................... 34 8.20.3 Matrix 2 of 5 Check Bit Verification...........................................................................................35 8.20.4 Matrix 2 of 5 Check Bit Transmission.......................................................................................35 8.21 Industrial 2 of 5........................................................................................................................................ 35 8.21.1 Industrial 2 of 5.............................................................................................................................35 8.21.2 Industrial 2 of 5 Identify Length................................................................................................. 35 8.21.3 Industrial 2 of 5 Check Bit Verification..................................................................................... 36 8.21.4 Industrial 2 of 5 Check Bit Transmission................................................................................. 36 8.22 Standard 2 of 5........................................................................................................................................ 36 8.22.1 Standard 2 of 5.............................................................................................................................36 8.22.2 Standard 2 of 5 Identify Length................................................................................................. 36 8.22.3 Standard 2 of 5 Check Bit Verification..................................................................................... 37 8.22.4 Standard 2 of 5 Check Bit Transmission................................................................................. 37 8.23 Code 39.................................................................................................................................................... 37 8.23.1 Code 39......................................................................................................................................... 37

IV

www.hzgrow.com

8.23.2 Code 39 Length............................................................................................................................37 8.23.3 Code 39 Check Bit Verification..................................................................................................38 8.23.4 Code 39 Check Bit.......................................................................................................................38 8.23.5 Code39 Transmit Start Character and Stop Character.........................................................38 8.24 Code 39 Full ASCII................................................................................................................................. 38 8.25 Code 32.................................................................................................................................................... 38 8.25.1 Code 32......................................................................................................................................... 38 8.25.2 Code 32 Add the Prefix A........................................................................................................... 39 8.25.3 Code 32 Check Bit Verification..................................................................................................39 8.25.4 Code 32 Check Bit Transmission..............................................................................................39 8.26 Code 93.................................................................................................................................................... 39 8.26.1 Code93.......................................................................................................................................... 39 8.26.2 Code93 Length.............................................................................................................................40 8.26.3 Code 93 Check Bit Verification..................................................................................................40 8.26.4 Code 93 Check Bit Transmission..............................................................................................40 8.27 Code 11.....................................................................................................................................................40 8.27.1 Code 11......................................................................................................................................... 40 8.27.2 Code 11 Length............................................................................................................................40 8.27.3 Code 11 Check Bit Verification.................................................................................................. 41 8.27.4 Code 11 Check Bit Transmission.............................................................................................. 41 8.28 Codabar.................................................................................................................................................... 41 8.28.1 Codabar.........................................................................................................................................41 8.28.2 Codabar Length........................................................................................................................... 41 8.28.3 Start and End Character Formats.............................................................................................41 8.28.4 Start and End Character Send.................................................................................................. 42 8.29 MSI.............................................................................................................................................................42 8.29.1 MSI................................................................................................................................................. 42 8.29.2 MSI Length....................................................................................................................................42 8.30 GS1-Databar............................................................................................................................................ 42 8.31 GS1 Composite Code............................................................................................................................ 43 8.32 QR Code...................................................................................................................................................43 8.32.1 QR Code....................................................................................................................................... 43 8.32.2 Read More Yards......................................................................................................................... 43

V

www.hzgrow.com

8.32.3 Forward and Backward Reading...............................................................................................43 8.33 Data Matrix............................................................................................................................................... 44
8.33.1 Data Matrix....................................................................................................................................44 8.33.2 Data Matrix Read More Yards................................................................................................... 44 8.33.3 Forward and Backward Reading...............................................................................................44 8.34 PDF 417....................................................................................................................................................44 8.34.1 PDF 417........................................................................................................................................ 44 8.34.2 PDF 417 Read More Yards........................................................................................................45 8.34.3 Forward and Backward Reading...............................................................................................45 8.35 Aztec Code............................................................................................................................................... 45 8.36 Maxi Code................................................................................................................................................ 45 8.37 Han Letter Codes.................................................................................................................................... 45 8.38 Brazil Bank Code.....................................................................................................................................46 Appendix 1Digital Setting Code.........................................................................................................................47 Appendix 2Cancel Barcode................................................................................................................................48 Appendix 3: Code ID................................................................................................................................................49 Appendix 4: Character Comparison Table........................................................................................................... 50 Appendix 5: Supported Barcode Type..................................................................................................................55 Appendix 6: Serial Port Instruction........................................................................................................................56 Appendix 7: Mirror....................................................................................................................................................77

VI

www.hzgrow.com

1 Introduction of Module

1.1 Introduction

GM67 1D 2D barcode scanner, with high integration and compact size, can be easily integrated into various industrial equipment and application environments. It can not only read various 1d barcode easily, but also read 2d barcode at high speed.It has a very high scanning rate for linear bar codes.For barcode on paper and screen, can also be easily scanned.
1.2 Technical Specification

Scanning Performance
Mechanical/

Scan Mode Lighting Collimate

Read Code Type

2D 1D

Accuracy of reading EAN-13
Depth Code 39 of Field
QR Code Data Marix PDF417 Contrast Scanning angle
Viewing Angle Interface

640*480 CMOS White LED Red LED QR Code, Data Matrix, PDF417,Aztec,Micro QR,Micro PDF417 EAN,UPC,Code 39,Code 93,Code 128,UCC/EAN 128, Codabar, Interleaved 2 of 5, ITF-6,ITF-14,ISBN,ISSN, MSI-Plessey GS1 Databar ,Code 11,Industrial 25, Standard 25,Plessey, Matrix 2 of 5
5mil 60mm-220mm (13mil) 40mm-90mm (5mil 10 byte)
30mm-220mm (20mil 16 byte) 40mm-110mm (10mil 20 byte) 30mm-130mm (6.67mil 7 byte) 25% Intersection angle 360�,Elevation � 55� Deflection angle � 55� D:42� H:34� V:26� TTL-232 , USB (HID-KBW, Virtual serial port)

1

Electrical Parameters

Dimension Operating Voltage

27.5(W)*46.5(D)*14(H)mm DC 5 V

Operating Current 180mA

Standby Current

USB:25mA; TTL:10mA

Environmental Operating

-20~+50

Parameters Temperature

Storage Temperature -40~+70

Operating Humidity 5%~95%Non-Condensing

Environmental Light 0~100000LUX

1.3 Dimension (mm)

2

www.hzgrow.com

Circuit Board Diagram:

1.4 Scan Head Definition

The cable is 12PIN directly connected with FPC flexible line, with an interval of 0.5mm

PIN Input/Output Definition

Introductions

PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9
PIN10
PIN11
PIN12

Power Power Ground Input Output Input Output Ground Output
Output
-
Input

VCC VCC GND RX TX
DD+ GND BEEPER
DLED
NC
TRIG

Input+3.3V Input+3.3V Serial port receiver signal Serial port send signal USB : D-singal USB : D+singal sfn output, low level when free Decoding success light, low level when free Weak Pull-up, Low level trigger engine decoding

3

www.hzgrow.com

1.5 Circuit Board Communication Interface
UART Communication interface definition:

Pin Name Definition

Description

1

5V Power Input Power input 5V

2

TX

Out

Data output. TTL logical level

3

RX

In

Data input. TTL logical level

4

GND

-

Signal ground

USB Communication interface definition:

Pin Name Definition

Description

1

5V Power Input Power input 5V

2

D+

Out

USB data output

3

D-

In

USB data input

4 GND

-

Signal ground

4

www.hzgrow.com

1.6 Scanning Area Map
Indicator area 32�, Visual angle 34�, lighting area 45�

1.7 Readable Barcode Type

Type UPC/EAN Code 128/EAN128 GS1-128 ISBT-128 Standard 2 of 5 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Code 39 Code 32 Code 93 Code 11 Codabar

Readable             

5

Default     �  � �  � � � �

www.hzgrow.com

PLESSEY



�

MSI



�

GS1 Databar



�

ITF-14



�

QR code





Data Matrix





PDF417





Aztec



�

Micro QR





Micro PDF417





6

www.hzgrow.com

2 Factory Mode Information
2.1 Factory Default Configuration

2.2 Setup Code

Factory default setting

*Setup code on

Off

2.3 Allow Send the Setup Code Information

Allow

*Forbid

7

www.hzgrow.com

3 Communication Interface
3.1 Serial Port
It's default and common to connect module and mainframe(such as PC, POS) by series communication interface. Make sure communication parameter for module and mainframe are same, then it will communicate smooth and correctly. Serial port related configuration: Baud rate:9600, Data bit:8, Verification: No, Stop bit:1

3.1.1 Baud rate

TTL 232 Interface

1200bps

2400bps

4800bps

*9600bps(Default)

19200bps

38400bps

57600bps

115200bps

8

www.hzgrow.com

3.1.2 Parity Bit

Odd number
3.1.3 Stop Bit

Even number

*No parity

*1 bit stop bit
3.2 USB KBW

2 bit stop bit

USB KBW Keyboard
3.3 USB COM Keyboard

USB COM

9

www.hzgrow.com

4 Read Mode
4.1 Manual Mode
4.1.1 Button Holding Mode
Set to button holding mode, press the button to trigger reading, and release the button to end reading. If the reading is successful or the reading time exceeds the single reading time, the reading will be finished.

*Manual Mode- Button Holding
4.1.2 Button Trigger Mode
Set to the button trigger mode, press the button to start reading, release the button, read will not stop. If the reading is successful or the reading time exceeds the single reading time, the reading will be finished.

*Manual Mode- Button Trigger
4.2 Continuous Mode
On this mode, reading module read code continuous and automatic. Read successfully or the reading time exceeds the single reading time,the reading will be finished,and automatically trigger the next reading.

Continuous Mode
10

www.hzgrow.com

4.2.1 Break Time Settlement
Time between two read. Default:500ms, Unit:100ms, Range:0-9900ms You can set the break time by scanning the bar code, example: Set 0.5ms, first scan the bar code below. Then scan the "0" and "5" bar code in the Digital Setting Code (Appendix 1).
Break time settlement
4.3 Induction Mode
In automatic sensing mode, the reading engine detects the brightness of the surrounding environment. When the brightness changes, module will begin to read, read successfully or the reading time exceeds the single reading time,the reading will be finished. Regardless of the last read success or failure, the module will be redetects the brightness of the surrounding environment.

Induction Mode
4.3.1 Stable Induction Time
Stable time before entering the test environment. Default: 500ms, Unit:100ms, Range:0-9900ms You can set the stable time by scanning the bar code, example: Set 200ms,first scan the bar code below. Then scan the "0" and "2" bar code in the Digital Setting Code (Appendix 1). Set 1500ms,first scan the bar code below. Then scan the "1" and "5" bar code in the Digital Setting Code (Appendix 1).

11

www.hzgrow.com

Stable Induction Time
4.3.2 Sensitivity Rating Setting
There are three levels of sensitivity to choose from, default: high sensitivity.

*High Sensitivity

Medium Sensitivity

Low Sensitivity

4.4 Host Mode
Through the instruction to trigger the reading engine, and it can end the reading by instruction, read successfully or the reading time exceeds the single reading time,the reading will be finished.

4.5 Single Scan Time

Host Mode

This parameter is the duration of a single decoding. Time from 0.5s to 25.5s, step size 0.1s. Default 3s. Example:
Set 0.5s, first scan the bar code below. Then scan the "0","0" and "5" bar code in the Digital Setting Code (Appendix 1).
Set 10.5s, first scan the bar code below. Then scan the "1","0" and "5" bar code in the Digital Setting Code (Appendix 1).

Single scan time
12

www.hzgrow.com

4.5.1 Single Scan Time Quickly Set Up

Infinite

3s

5s

10s

15s

20s

4.6 Time Interval For The Same Code Read
It means, after reading a barcode, refuse to read the same code for a set period of time. Only after a set period of time, it can be able to read and output. Default: 500ms, Unit:100ms, Range:0-9900ms.
Mainly for continuous mode and automatic induction mode. Example: Set 0.5s, first scan the bar code below. Then scan the "0" and "5" bar code in the Digital Setting Code (Appendix 1).

Time Interval For The Same Code Read
4.6.1 Same Code Quickly Set Up

No delay

Delay 1s

Delay 3s

Delay 5s

Delay 7s
13

Infinite delay
www.hzgrow.com

5 Lighting and Collimate
5.1 Lighting
Head lamp is used to additional lighting when read.

*The light turn on only when read (Default)

Always on

Always off

5.2 Collimation
There will be a pointing light beam which can help user to find best distance. Note: Flashing and non-flashing functions only work if the collimation LED is set to be Always on or on when read. After the LED is set to be off, if you want to set the LED flashing function, please first set the collimation LED to be Always on or on when reading.

*The light turn on only when read (Default)

Always on

Always off

Flashing

Non-Flashing

14

www.hzgrow.com

6 Prompts
6.1 Keyboard
6.1.1 Keyboard Settlement
Scan following code to change keyboard.

*American English(Default)

Belgium

Finland

Austria,Germany

France

Italy

Sweden

UK

Denmark

Spain

Norway

Portugal

Turkey F

Turkey Q

Japan

15

Russia
www.hzgrow.com

Czech

Thailand

Ukraine

Brazil(ABNT2)

Greek

Hungary

Netherlands

Poland(214)

Romania (standard)

Slovakia

6.1.2 Keyboard Type
After enabling the virtual keyboard, you can output the correct data in any keyboard language mode. When using virtual keyboard, you must make sure the keypad number keys are valid.

*Standard Keyboard

Virtual Keyboard

16

www.hzgrow.com

6.1.3 Keyboard Output Character Time Interval
Time from 0ms to 1000ms Unit: 5ms Default: 5ms

0ms

10ms

6.1.4 ASCII Control Character Output Mode Selection
Control character (0x00-0x20) output mode selection in ASCII code Output function keys: control characters are used as custom function keys. See appendix 4 for specific functions Output Ctrl combination key (this function is used with prefix and suffix) : Ctrl combination key output control characters, specific functions are shown in appendix 4 ALT output control characters: full control character output is supported in Chinese environment, refer to standard ASCII table for details Output Enter and DownArrow: mask other control characters, output only: 0x07 output Enter,0x0A output DownArrow, 0x0D output Enter.

Output function keys(0x00)

Output Ctrl combination key(0x01)

ALT output control characters(0x02)

Output Enter and DownArrow(0x03)

17

www.hzgrow.com

6.2 Prompts Tone
6.2.1 Buzzer Type
*Passive Buzzer
6.2.2 Silent Mode
Close All Prompts
6.2.3 Volume Level
Default: high pitch

Active Buzzer *Forbid to Close All Prompts

*High Pitch

Middle

Low

6.2.4 Decoding Successful Prompt Tone

*Decoding Successful Prompt Tone ON

Decoding Successsful Prompt Tone OFF

6.2.5 Starting Up Prompt
18

www.hzgrow.com

*Starting Up Prompt ON
6.2.6 Setup Code Prompt

Starting Up Prompt OFF

*Setup Code Prompt ON

Setup Code Prompt OFF

6.3 Decoding Successful Prompt Light
Decoding success prompt light on a certain time, the premise is that the prompt light is used as a decoding prompt.

Forbid
6.4 Decoding Prompt Working Mode

*Allow

*Power on Always off

Power on Always on

6.5 Decoding Prompt
If the barcode cannot be decoded within the timeout period before releasing the trigger button, it is allowed to send "unread" messages.Any possible prefix or suffix can be attached to this message.

19

www.hzgrow.com

When this function is disabled, no message can be sent to the host even if the barcode cannot be decoded.

*Forbid sending NR

Allow sending NR

6.6 Keyboard Output Force Letter Case Conversion
Example: If the barcode is ab123dE, if scan the "convert to uppercase" bar code, the output is AB123DE; if scan the "convert to lowercase" bar code,the output is abc123de.
Default: Keyboard case is not converted.

*Keyboard case is not converted

All uppercase

All lowercase

Case reversal

6.7 Data Code Format

Read following to print Chinese data according to specified code format

0: Original type

1:GBK format: notepad, EXCEL

2: UNICODE format: WORD and input box for chat tools

Original Type

*GBK
20

Unicode
www.hzgrow.com

7 Data Edition
7.1 CODE ID
Users can identify different types of bar code by CODE ID. CODE ID use one character to identify and can be self- defined. Pls see the Appendix 3.

*Not allowed to send ID

Allowed to send ID

7.2 Terminator Character
Terminator character is add character format after decoding data: decoded data + terminator character.

*No Terminator

# &CR LF

%CR

TAB

CRCR

CR LF CR LF

21

www.hzgrow.com

7.3 Add Prefix and Suffix
7.3.1 Prefix
1) Scan "Set Multiple Prefixes" setting code
Set Multiple Prefixes in succession 2) Scan the digital setting code in turn, and there will be a successful tone for every four 3) Scan "Finish Setting Multiple Prefixes Suffixes" setting code and finish setting
Finish Setting Multiple Prefixes Suffixes
7.3.2 Suffix(Similar to a prefix, you can add a newline to suffix if you need a newline)
1) Scan "Set Multiple Suffixes" setting code
Set Multiple Suffixes in succession 2) Set Suffixes 3) Scan "Finish Setting Multiple Prefixes Suffixes" setting code and finish setting
Finish Setting Multiple Prefixes Suffixes

22

www.hzgrow.com

7.3.3 Prefix Suffix Take Effect

*Only output the decoded data

Output multiple Suffixes

Output multiple Prefixes

Output multiple Prefixes and Suffixes

7.4 Hide Header, Middle and Tail Characters
7.4.1 Hide Header Characters
Decoding data for header data hiding, it can be configured to hide any length. If the configured length exceeds the barcode data length, all contents of the current barcode are hidden

*Forbid

Allow

Set the number of Hide Header Characters Set the number of Hide Header Characters, ranging from 1 to 255. Scan the follow barcode and then scan the digital setting code. For example, if 16 characters need to be hidden, then scan the digital setting code sequentially: 0, 1 and 6.

The number of Hide Header Characters
23

www.hzgrow.com

7.4.2 Hide Middle Characters
Decoding data for middle data hiding,and any starting position and length can be configured. If the starting position of the configuration exceeds the barcode data length, the current barcode is not hidden. If the configured length exceeds the remaining barcode data length, all barcode data after the start location is hidden.

*Forbid

Follow

Sets the Start Location of Hide Middle Characters Sets the start location of hide middle characters,ranging from 1 to 255. Scan the follow barcode and then scan the digital setting code. For example, if you need to hide data after the third character (starting with the fourth character),scan the digital setting code successively: 0 0 3.

The start bit of Hide Middle Characters
Sets the Length of Hide Middle Characters Sets the length of hide middle characters,ranging from 1 to 255. Scan the follow barcode and then scan the digital setting code. For example, if 16 characters need to be hidden, then scan the digital setting code sequentially: 0, 1 and 6.

The Length of Hide Middle Characters

24

www.hzgrow.com

7.4.3 Hide Tail Characters
Decoding data for tail data hiding, it can be configured to hide any length. If the configured length exceeds the barcode data length, all contents of the current barcode are hidden.

*Forbid

Follow

Set the number of Tail Header Characters

Set the number of Tail Header Characters, ranging from 1 to 255.

Scan the follow barcode and then scan the digital setting code. For example, if 16 characters need to be hidden, then scan the digital setting code sequentially: 0, 1 and 6.

The number of Tail Header Characters
7.5 Set STX and ETX

Forbid

STX Prefix

ETX Suffix 1

STX(Prefix)+ETX(Suffix 1)

25

www.hzgrow.com

8 All Types of Bar Code Can be Decoded
8.1 1D Code Global Enable Switch

Allow
8.2 2D Code Global Enable Switch

Forbid

Allow

Forbid

8.3 Forward and backward reading of 1D Code

Allow
8.4 UPC-A
8.4.1 UPC-A

Forbid

*Allow

Forbid

26

www.hzgrow.com

8.4.2 UPC-A Leading Code

No Leading Code
8.4.3 UPC-A Check Bit

*System Characters (Default) System Character & Country Code

UPC-A Check bit is not transmitted
8.5 UPC-A Extra Code
8.5.1 UPC-A 2-bit Extra Code

*Transmit UPC-A Check bit

Allow
8.5.2 UPC-A 5-bit Extra Code

*Forbid

Allow
8.5.3 UPC-A Extra Code Must be Identified

*Forbid

Allow

*Forbid

27

www.hzgrow.com

8.6 UPC-E
8.6.1 UPC-E

*Allow
8.6.2 UPC-E Leading Code

Forbid

*No Leading Code System Characters (Default) System Character & Country Code
8.6.3 UPC-E Check Bit

UPC-E Check bit is not transmitted
8.7 UPC-E Extra Code
8.7.1 UPC-E 2-bit Extra Code

*Transmit UPC-E Check bit

Allow

*Forbid

28

www.hzgrow.com

8.7.2 UPC-E 5-bit Extra Code

Allow
8.7.3 UPC-E Extra Code Must be Identified

*Forbid

Allow
8.8 UPC-E Turn UPC-A

*Forbid

Allow
8.9 UPC-A Turn EAN-13

*Forbid

Allow
8.10 UPC-E1

*Forbid

Allow

Forbid
29

www.hzgrow.com

8.11 EAN-8
8.11.1 EAN-8
*Allow
8.11.2 EAN-8 Check Bit
Forbid
8.12 EAN-8 Extra Code
8.12.1 EAN-8 2-bit Extra Code
Allow
8.12.2 EAN-8 5-bit Extra Code
Allow

Forbid Allow
*Forbid *Forbid

30

www.hzgrow.com

8.12.3 EAN-8 Extra Code Must be Identified

Allow
8.13 EAN-13
8.13.1 EAN-13

*Forbid

*Allow
8.13.2 EAN-13 Check Bit

Forbid

Forbid

*Allow

8.14 Bookland EAN(ISBN)
When ISBN are forbidden, they are treated as EAN13

Allow (0x01)

*Forbid (0x00)

31

www.hzgrow.com

8.15 EAN-13 Extra Code
8.15.1 EAN-13 2-bit Extra Code

Allow
8.15.2 EAN-13 5-bit Extra Code

*Forbid

Allow
8.15.3 EAN-13 Extra Code Must be Identified

*Forbid

Allow
8.16 CODE 128

*Forbid

*Allow

Forbid

32

www.hzgrow.com

8.17 GS1-128(UCC/EAN-128)

*Allow
8.18 ISSN
Turn to EAN13 when forbidded.
Allow
8.19 Interleaved 2 of 5
8.19.1 I 2 of 5

Forbid *Forbid

*Allow
8.19.2 Interleaved 2 of 5 Identify Length

Forbid

Users can set to decode Interleaved 2 of 5 within a certain length range. Example:Set to decode only Interleaved 2 of 5 within 4-20 bit length range. First scan the bar code below, and then scan 0,4,2,0 bar code in Appendix 1 in sequence. Change the selection or cancel an incorrect input setting, scan the bar code in Appendix 2.

33

www.hzgrow.com

Industrial 2 of 5 within a certain length range

Industrial 2 of 5 in any length range

8.19.3 Interleaved 2 of 5 Check Bit Verification

Allow
8.19.4 Interleaved 2 of 5 Check Bit Transmission

*Forbid

Allow
8.20 Matrix 2 of 5
8.20.1 Matrix 2 of 5

*Forbid

Allow

*Forbid

8.20.2 Matrix 2 of 5 Identify Length
Users can set to decode Matrix 2 of 5 within a certain length range. Example:Set to decode only Matrix 2 of 5 within 4-20 bit length range. First scan the bar code below, and then scan 0,4,2,0 bar code in Appendix 1 in sequence. Change the selection or cancel an incorrect input setting, scan the bar code in Appendix 2.

34

www.hzgrow.com

Matrix 2 of 5 within a certain length range

Matrix 2 of 5 in any length range

8.20.3 Matrix 2 of 5 Check Bit Verification

Allow
8.20.4 Matrix 2 of 5 Check Bit Transmission

*Forbid

Allow
8.21 Industrial 2 of 5
8.21.1 Industrial 2 of 5

*Forbid

Allow
8.21.2 Industrial 2 of 5 Identify Length

*Forbid

Users can set to decode Industrial 2 of 5 within a certain length range. Example:Set to decode only Industrial 2 of 5 within 4-20 bit length range. First scan the bar code below, and then scan 0,4,2,0 bar code in Appendix 1 in sequence. Change the selection or cancel an incorrect input setting, scan the bar code in Appendix 2.

35

www.hzgrow.com

Industrial 2 of 5 within a certain length range

Industrial 2 of 5 in any length range

8.21.3 Industrial 2 of 5 Check Bit Verification

Allow
8.21.4 Industrial 2 of 5 Check Bit Transmission

*Forbid

Allow
8.22 Standard 2 of 5
8.22.1 Standard 2 of 5

*Forbid

Allow
8.22.2 Standard 2 of 5 Identify Length

*Forbid

Users can set to decode Standard 2 of 5 within a certain length range. Example:Set to decode only Standard 2 of 5 within 4-20 bit length range. First scan the bar code below, and then scan 0,4,2,0 bar code in Appendix 1 in sequence. Change

36

www.hzgrow.com

the selection or cancel an incorrect input setting, scan the bar code in Appendix 2.

Standard 2 of 5 within a certain length range

Standard 2 of 5 in any length range

8.22.3 Standard 2 of 5 Check Bit Verification

Allow
8.22.4 Standard 2 of 5 Check Bit Transmission

*Forbid

Allow
8.23 Code 39
8.23.1 Code 39

*Forbid

*Allow
8.23.2 Code 39 Length

Forbid

37

www.hzgrow.com

Can solve for any length of code39
8.23.3 Code 39 Check Bit Verification

Verification check bit
8.23.4 Code 39 Check Bit

*Check bits are not validated

Transmission Check Bit

*No check bits are transmitted

8.23.5 Code39 Transmit Start Character and Stop Character

Allow
8.24 Code 39 Full ASCII

*Forbid

Allow
8.25 Code 32
8.25.1 Code 32

*Forbid

38

www.hzgrow.com

Allow
8.25.2 Code 32 Add the Prefix A

*Forbid

Allow
8.25.3 Code 32 Check Bit Verification

*Forbid

*Forbid
8.25.4 Code 32 Check Bit Transmission

Allow

*Transmission check bit
8.26 Code 93
8.26.1 Code93

Transmission start, stop, check bit

Allow

*Forbid

39

www.hzgrow.com

8.26.2 Code93 Length

Can read for any length of code93
8.26.3 Code 93 Check Bit Verification

Allow
8.26.4 Code 93 Check Bit Transmission

*Forbid

Allow
8.27 Code 11
8.27.1 Code 11

*Forbid

Allow
8.27.2 Code 11 Length

*Forbid

Can solve for any length of code11
40

www.hzgrow.com

8.27.3 Code 11 Check Bit Verification

Allow

One check bit

8.27.4 Code 11 Check Bit Transmission

Two check bit

Allow
8.28 Codabar
8.28.1 Codabar

*Forbid

Allow
8.28.2 Codabar Length

*Forbid

Can solve for any length of Codabar
8.28.3 Start and End Character Formats
T initiators and terminators are allowed to be one of the four characters: "A", "B", "C", "D";The terminator is also allowed to be one of the four characters "T", "N", "*", "E".

41

www.hzgrow.com

*ABCD/ABCD
8.28.4 Start and End Character Send

ABCD/TN*E

Remove the start and stop characters
8.29 MSI
8.29.1 MSI

*Allow start and stop characters

Allow
8.29.2 MSI Length

*Forbid

Can read for any length of MSI
8.30 GS1-Databar

Allow

*Forbid

42

www.hzgrow.com

8.31 GS1 Composite Code

Allow
8.32 QR Code
8.32.1 QR Code

*Forbid

*Allow
8.32.2 Read More Yards

Forbid

Only Read Single Code

Only read Dicode

8.32.3 Forward and Backward Reading

Single and Dicode can be recognized

*Only read Forward

Forward and Backward both can read

43

www.hzgrow.com

8.33 Data Matrix
8.33.1 Data Matrix

*Allow
8.33.2 Data Matrix Read More Yards

Forbid

Only Read Single Code

Only read Dicode

8.33.3 Forward and Backward Reading

Single and Dicode can be recognized

Only read Forward

Only read Backward

8.34 PDF 417
8.34.1 PDF 417

Forward and Backward both can read

*Allow

Forbid

44

www.hzgrow.com

8.34.2 PDF 417 Read More Yards

Only Read Single Code

Only read Dicode

8.34.3 Forward and Backward Reading

Single and Dicode can be recognized

Only read Forward

Only read Backward

8.35 Aztec Code

Forward and Backward both can read

Allow
8.36 Maxi Code

*Forbid

Allow
8.37 Han Letter Codes

*Forbid

Allow

*Forbid

45

www.hzgrow.com

8.38 Brazil Bank Code
Allow

*Forbid

46

www.hzgrow.com

Appendix 1Digital Setting Code

0

1

2

3

4

5

6

7

8

9

47

www.hzgrow.com

Appendix 2Cancel Barcode
Change the selection or cancel an incorrect input, scan the bar code below.
Cancel

48

www.hzgrow.com

Appendix 3: Code ID
Code Characters
A B C D E F G H J K L R
V r u q a x c

Bar code Type
UPC-A, UPC-E, EAN-8, EAN-13 Code 39, Code 32 Codabar Code 128, ISBT 128 Code 93 Interleaved 2 of 5/ITF, ITF14 Industrial 2 of 5, Standard 2 of 5 CODE11 MSI, MSI/Plessey UCC/EAN-128/GS1-128 Bookland EAN/ISBNISSN GS1 DataBar-14, GS1 DataBar Limited, GS1 DataBar Expanded, RSS Matrix 25 PDF417 DataMatrix(DM) QR Aztec Code Maxi Code HanXin

49

www.hzgrow.com

Appendix 4: Character Comparison Table

Scan Value

Hexadecimal value

1000

00h

1001

01h

1002

02h

1003

03h

1004

04h

1005

05h

1006

06h

1007

07h

1008

08h

1009

09h

1010

0Ah

1011

0Bh

1012

0Ch

1013

0Dh

1014

0Eh

1015

0Fh

1016

10h

1017

11h

1018

12h

1019

13h

1020

14h

1021

15h

1022

16h

1023

17h

1024

18h

1025

19h

1026

1Ah

1027

1Bh

Keyboard Operation Null Keypad Enter Caps lock Right Arrow Up Arrow Null Null Enter Left Arrow Horizontal Tab Down Arrow Vertical Tab Backspace Enter Insert Esc F11 Home Print Screen Delete tab+shift F12 F1 F2 F3 F4 F5 F6

Keyboard+Ctrl Operation
CTRL 2 CTRL A CTRL B CTRL C CTRL D CTRL E CTRL F CTRL G CTRL H CTRL I CTRL J CTRL K CTRL L CTRL M CTRL N CTRL O CTRL P CTRL Q CTRL R CTRL S CTRL T CTRL U CTRL V CTRL W CTRL X CTRL Y CTRL Z CTRL [

50

www.hzgrow.com

1028

1Ch

1029

1Dh

1030

1Eh

1031

1Fh

1032

20h

1033

21h

1034

22h

1035

23h

1036

24h

1037

25h

1038

26h

1039

27h

1040

28h

1041

29h

1042

2Ah

1043

2Bh

1044

2Ch

1045

2Dh

1046

2Eh

1047

2Fh

1048

30h

1049

31h

1050

32h

1051

33h

1052

34h

1053

35h

1054

36h

1055

37h

1056

38h

1057

39h

1058

3Ah

1059

3Bh

F7 F8 F9 F10 Space /A /B /C /D /E /F /G /H /I /J /K /L . / 0 1 2 3 4 5 6 7 8 9 /Z %F
51

CTRL \ CTRL ] CTRL 6 CTRL Space ! ` # $ % & ` ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ;

www.hzgrow.com

1060

3Ch

1061

3Dh

1062

3Eh

1063

3Fh

1064

40h

1065

41h

1066

42h

1067

43h

1068

44h

1069

45h

1070

46h

1071

47h

1072

48h

1073

49h

1074

4Ah

1075

4Bh

1076

4Ch

1077

4Dh

1078

4Eh

1079

4Fh

1080

50h

1081

51h

1082

52h

1083

53h

1084

54h

1085

55h

1086

56h

1087

57h

1088

58h

1089

59h

1090

5Ah

1091

5Bh

%G

<

%H

=

%I

>

%J

?

%V

@

A

A

B

B

C

C

D

D

E

E

F

F

G

G

H

H

I

I

J

J

K

K

L

L

M

M

N

N

O

O

P

P

Q

Q

R

R

S

S

T

T

U

U

V

V

W

W

X

X

Y

Y

Z

Z

%K

[

52

www.hzgrow.com

1092

5Ch

1093

5Dh

1094

5Eh

1095

5Fh

1096

60h

1097

61h

1098

62h

1099

63h

1100

64h

1101

65h

1102

66h

1103

67h

1104

68h

1105

69h

1106

6Ah

1107

6Bh

1108

6Ch

1109

6Dh

1110

6Eh

1111

6Fh

1112

70h

1113

71h

1114

72h

1115

73h

1116

74h

1117

75h

1118

76h

1119

77h

1120

78h

1121

79h

1122

7Ah

1123

7Bh

%L

\

%M

]

%N

^

%O

_

%W

`

+A

a

+B

b

+C

c

+D

d

+E

e

+F

f

+G

g

+H

h

+I

i

+J

j

+K

k

+L

l

+M

m

+N

n

+O

o

+P

p

+Q

q

+R

r

+S

s

+T

t

+U

u

+V

v

+W

w

+X

x

+Y

y

+Z

z

%P

{

53

www.hzgrow.com

1124

7Ch

%Q

1125

7Dh

%R

1126

7Eh

%S

1127

7Fh

| } ~ Undefined

54

www.hzgrow.com

Appendix 5: Supported Barcode Type

Barcode Type

Hexadeci mal Value

Barcode Type

Hexadecimal Value

Not Applicable

0x00

EAN 13 with 5 Supps.

0x8B

Code 39

0x01

EAN 13

0x0B

Codabar

0x02

EAN 13 with 2 Supps.

0x4B

Code 128, Setup128 0x03

EAN 13 with 5 Supps.

0x8B

Discrete 2 of 5

0x04

MSI

0x0E

IATA 2 of 5

0x05

GS1-128

0x0F

Interleaved 2 of 5 0x06

UPC E1

0x10

Code 93

0x07 UPC E1 with 2 Supps.

0x50

UPC A

0x08 UPC E1 with 5 Supps.

0x90

UPC A with 2 Supps. 0x48

Trioptic Code 39

0x15

UPC A with 5 Supps. 0x88

Bookland EAN

0x16

UPC E0

0x09

Coupon Code

0x17

UPC E0 with 2 Supps.

0x49

GS1 DataBar-14

0x30

UPC E0 with 5 Supps.

0x89

GS1 DataBar Limited

0x31

EAN 8

0x0A GS1 DataBar Expanded

0x32

EAN 8 with 2 Supps 0x4A

Code11

0x0C

EAN 8 with 5 Supps 0x8A

PDF417

0xF0

QR

0xF1

Data Matrix(DM)

0xF2

Aztec Code

0xF3

Maxi Code

0xF4

Veri Code

0xF5

Han Xin

0xF7

AIM128

0xA2

ISSN

0xA3

PLESSEY

0xA4

55

www.hzgrow.com

Appendix 6: Serial Port Instruction

When the scanner is not working, it is in sleep mode.Under the sleep mode, need to wake up first, then send the effective instruction. To start decoding and stop decoding the serial port command needs to be valid in host mode. Please switch to the host mode first.

Table 6-1

Name

Instructions

CMD_ACK

04 D0 04 00 FF 28

CMD_NAK

RESEND:05 D1 04 00 01 FF 25

BAD_CONTEXT:05 D1 04 00 02 FF 24

DENIED:05 D1 04 00 06 FF 20

DECODE_DATA

None

LED_OFF

05 E8 04 00 01 FF 0E

LED_ON

05 E7 04 00 01 FF 0F

PARAM_DEFAULTS

04 C8 04 00 FF 30

PARAM_REQUEST

Listed in the table below

PARAM_SEND

Listed in the table below

REQUEST_REVISIO N

04 A3 04 00 FF 55

REPLY_REVISION

None

SCAN_DISABLE

04 EA 04 00 FF 0E

SCAN_ENABLE

04 E9 04 00 FF 0F

SLEEP

04 EB 04 00 FF 0D

START_DECODE

04 E4 04 00 FF 14

STOP_DECODE

04 E5 04 00 FF 13

WAKEUP

None

RESET

04 FA 04 00 FE FE

Custom buzzer sound

05 E6 04 00 00 FF 11 05 E6 04 00 01 FF 10

56

www.hzgrow.com

Table 6-2

Parameter Name

Serial Instructions

Default Configuration

Factory Default Configuration:08 C6 04 08 00 F2 FF 00 FD 35

Scanning duration

4s07 C6 04 08 00 88 28 FE 77

10s:07 C6 04 08 00 88 64 FE 3B

Single Scan Time(Scanning Infinite08 C6 04 08 00 F2 FA 00 FD 3A

duration)Quickly Set Up

3s08 C6 04 08 00 F2 FA 03 FD 37

5s08 C6 04 08 00 F2 FA 05 FD 35

10s08 C6 04 08 00 F2 FA 0A FD 30

15s08 C6 04 08 00 F2 FA 0B FD 2F

20s08 C6 04 08 00 F2 FA 0C FD 2E

30s08 C6 04 08 00 F2 FA 0D FD 2D

60s08 C6 04 08 00 F2 FA 0E FD 2C

Trigger Mode

Button Holding07 C6 04 08 00 8A 00 FE 9D

Button Trigger07 C6 04 08 00 8A 02 FE 9B

Continuous scanning07 C6 04 08 00 8A 04 FE 99

Automatic Induction: 07 C6 04 08 00 8A 09 FE 94

Host07 C6 04 08 00 8A 08 FE 95

Break Time Settlement

0s:07 C6 04 08 00 89 00 FE 9E

0.5s: 07 C6 04 08 00 89 05 FE 99

3s07 C6 04 08 00 89 1E FE 80

Buzzer Voice

Low07 C6 04 08 00 8C 02 FE 99

Middle: 07 C6 04 08 00 8C 01 FE 9A

High: 07 C6 04 08 00 8C 00 FE 9B

Buzzer Type

*Passive Buzzer: 08 C6 04 08 00 F2 D8 00 FD 5C

Active Buzzer: 08 C6 04 08 00 F2 D8 01 FD 5B

57

www.hzgrow.com

Decoding Prompt Tone

Successful On07 C6 04 08 00 38 01 FE EE Off07 C6 04 08 00 38 00 FE EF

Terminator Character Setting Forbid:08 C6 04 08 00 F2 05 00 FE 2F

CR LF:08 C6 04 08 00 F2 05 01 FE 2E

CR:08 C6 04 08 00 F2 05 02 FE 2D

TAB: 08 C6 04 08 00 F2 05 03 FE 2C

CR CR08 C6 04 08 00 F2 05 04 FE 2B

CR LF CR LF08 C6 04 08 00 F2 05 05 FE 2A

Decoding Prompt Light

Successful Forbid: 08 C6 04 08 00 F2 0B 00 FE 29 Allow: 08 C6 04 08 00 F2 0B 01 FE 28

Decoding Prompt Light Power on Always off: 08 C6 04 08 00

Control

F2 CB 00 FD 69

Power on Always on: 08 C6 04 08 00 F2 CB 01 FD 68

Silent

Forbid: 08 C6 04 08 00 F2 0C 00 FE 28

Allow: 08 C6 04 08 00 F2 0C 01 FE 27

Starting Up Prompt

Forbid: 08 C6 04 08 00 F2 0D 00 FE 27

Allow: 08 C6 04 08 00 F2 0D 01 FE 26

Setup Code Prompt

Forbid: 08 C6 04 08 00 F2 0E 00 FE 26

Allow: 08 C6 04 08 00 F2 0E 01 FE 25

Send "Not read" message On07 C6 04 08 00 5E 01 FE C8

Off07 C6 04 08 00 5E 00 FE C9

Allows scan configuration On07 C6 04 08 00 EC 01 FE 3A

bar code

Off07 C6 04 08 00 EC 00 FE 3B

Send the Setup Code On08 C6 04 08 00 F1 71 01 FD C3

Information

Off08 C6 04 08 00 F1 71 00 FD C4

Prefix/Suffix Value

Prefix string setting 31

Prefix

Suffix string setting 32 33 

Suffix 1 Suffix 2

0B C6 04 08 00 69 31 68 32 6A 33 FD 52 Prefix:0x00

Suffix 0x0D 0x0A Implement a newline

58

www.hzgrow.com

Scan Data Send Format
Baud rate Parity Decoded packet format

0B C6 04 08 00 69 00 68 0D 6A 0A FD D1 Code07 C6 04 08 00 EB 00 FE 3C Code+Suffix07 C6 04 08 00 EB 01 FE 3B Code+Suffix 207 C6 04 08 00 EB 02 FE 3A Code+Suffix 1+Suffix 207 C6 04 08 00 EB 03 FE 39 Prefix+Code07 C6 04 08 00 EB 04 FE 38 Prefix+Code+Suffix 107 C6 04 08 00 EB 05 FE 37 Prefix+Code+Suffix 207 C6 04 08 00 EB 06 FE 36 Prefix+Code+Suffix 1+Suffix 2  07 C6 04 08 00 EB 07 FE 35 120007 C6 04 08 00 9C 03 FE 88 240007 C6 04 08 00 9C 04 FE 87 480007 C6 04 08 00 9C 05 FE 86 960007 C6 04 08 00 9C 06 FE 85 1920007 C6 04 08 00 9C 07 FE 84 3840007 C6 04 08 00 9C 08 FE 83 5760007 C6 04 08 00 9C 09 FE 82 11520007 C6 04 08 00 9C 0A FE 81 Odd number  07 C6 04 08 00 9E 00 FE 89 Even number 07 C6 04 08 00 9E 01 FE 88 Tag 07 C6 04 08 00 9E 02 FE 87 Black space07 C6 04 08 00 9E 03 FE 86 None 07 C6 04 08 00 9E 04 FE 85 Send the original decoded data07 C6

59

www.hzgrow.com

04 08 00 EE 00 FE 39

Send the decoded data of data packet 07 C6 04 08 00 EE 01 FE 38

Host serial response times 0.1s: 07 C6 04 08 00 9B 01 FE 8B out

Stop Bit

1 bit stop bit: 07 C6 04 08 00 9D 01 FE 89

2 bit stop bit: 07 C6 04 08 00 9D 02 FE 88

Intercharacter Delay

1s: 07 C6 04 08 00 6E 01 FE B8

Host Character Timeout

500ms:07 C6 04 08 00 EF 32 FE 06

200ms:07 C6 04 08 00 EF 14 FE 24

50ms: 07 C6 04 08 00 EF 05 FE 33

Communication Interface

Serial:08 C6 04 08 00 F2 01 00 FE 33

USB KBW:08 C6 04 08 00 F2 01 01 FE 32

USB Serial: 08 C6 04 08 00 F2 01 02 FE 31

HID POS:08 C6 04 08 00 F2 01 0E FE 25

PS2 Mode

AUTO: 08 C6 04 08 00 F2 A6 00 FD 8E

Single PS2: 08 C6 04 08 00 F2 A6 01 FD 8D

Lighting Control

The light turn on only when read :08 C6 04 08 00 F2 02 00 FE 32

Always on :08 C6 04 08 00 F2 02 01 FE 31

Always off : 08 C6 04 08 00 F2 02 02 FE 30

Collimation Control

The light turn on only when read :08 C6 04 08 00 F2 03 00 FE 31

Always on :08 C6 04 08 00 F2 03 01 FE 30

Always off : 08 C6 04 08 00 F2 03 02

60

www.hzgrow.com

FE 2F

Collimation whether flashing *Flashing: 08 C6 04 08 00 F2 B8 00 FD 7C

Not Flashing: 08 C6 04 08 00 F2 B8 01 FD 7B

Sensitivity Rating

Super High Sensitivity:08 C6 04 08 00 F2 04 00 FE 30

High Sensitivity:08 C6 04 08 00 F2 04 01 FE 2F

Medium Sensitivity:08 C6 04 08 00 F2 04 02 FE 2E

Low Sensitivity:08 C6 04 08 00 F2 04 03 FE 2D

Custom Sensitivity

00:08 C6 04 08 00 F3 01 00 FE 32

01:08 C6 04 08 00 F3 01 01 FE 31

05:08 C6 04 08 00 F3 01 05 FE 2D

10:08 C6 04 08 00 F3 01 0A FE 28

15:08 C6 04 08 00 F3 01 0F FE 23

Stable Induction Time

500ms:08 C6 04 08 00 F3 02 05 FE 2C

1000ms:08 C6 04 08 00 F3 02 0A FE 27

300ms: 08 C6 04 08 00 F3 02 03 FE 2E

1D Backward Reading

Barcode Forbid08 C6 04 08 00 F2 91 00 FD A3 Allow08 C6 04 08 00 F2 91 01 FD A2

Output Character Set Type

Original: 08 C6 04 08 00 F2 06 00 FE 2E

GBK:08 C6 04 08 00 F2 06 01 FE 2D

UNICODE:08 C6 04 08 00 F2 06 02 FE 2C

Keyboard Settlement

America: 08 C6 04 08 00 F6 01 01 FE 2E

Belgium: 08 C6 04 08 00 F6 01 02 FE 2D

BrazilABNT208 C6 04 08 00 F6 01

61

www.hzgrow.com

03 FE 2C Denmark: 08 C6 04 08 00 F6 01 06 FE 29 Finland: 08 C6 04 08 00 F6 01 07 FE 28 France: 08 C6 04 08 00 F6 01 08 FE 27 Austria,Germany: 08 C6 04 08 00 F6 01 09 FE 26 Greek08 C6 04 08 00 F6 01 0A FE 25 Hungary08 C6 04 08 00 F6 01 0B FE 24 Italy: 08 C6 04 08 00 F6 01 0D FE 22 Netherlands08 C6 04 08 00 F6 01 0F FE 20 Norway: 08 C6 04 08 00 F6 01 10 FE 1F Poland08 C6 04 08 00 F6 01 11 FE 1E Portugal : 08 C6 04 08 00 F6 01 12 FE 1D RomaniaStandard08 C6 04 08 00 F6 01 13 FE 1C Russia: 08 C6 04 08 00 F6 01 14 FE 1B Slovakia: 08 C6 04 08 00 F6 01 15 FE 1A Spain: 08 C6 04 08 00 F6 01 16 FE 19 Sweden: 08 C6 04 08 00 F6 01 17 FE 18 Turkey_F: 08 C6 04 08 00 F6 01 19 FE 16 Turkey_Q: 08 C6 04 08 00 F6 01 1A FE 15 UK: 08 C6 04 08 00 F6 01 1B FE 14 Japan: 08 C6 04 08 00 F6 01 1C FE 13 Czech: 08 C6 04 08 00 F6 01 1D FE 12 Thailand Keyboard Kedmanee 08 C6

62

www.hzgrow.com

04 08 00 F6 01 1E FE 11

Ukraine08 C6 04 08 00 F6 01 1F FE 10

Arabic Language_10108 C6 04 08 00 F6 01 20 FE 0F

Croatia08 C6 04 08 00 F6 01 21 FE 0E

Korea08 C6 04 08 00 F6 01 22 FE 0D

Bulgaria08 C6 04 08 00 F6 01 23 FE 0C

Keyboard Output Character 0ms: 08 C6 04 08 00 F3 04 00 FE 2F

Time Interval

5ms: 08 C6 04 08 00 F3 04 01 FE 2E

10ms: 08 C6 04 08 00 F3 04 02 FE 2D

Keyboard Output Character 0ms: 08 C6 04 08 00 F2 B2 00 FD 82 Time Interval Quickly Set Up 10ms: 08 C6 04 08 00 F2 B2 01 FD 81

50ms: 08 C6 04 08 00 F2 B2 02 FD 80

Keyboard Output Force Keyboard case is not converted: 08 C6

Letter Case Conversion

04 08 00 F2 A1 00 FD 93

All uppercase: 08 C6 04 08 00 F2 A1 01 FD 92

All lowercase: 08 C6 04 08 00 F2 A1 02 FD 91

Case reversal: 08 C6 04 08 00 F2 A1 03 FD 90

Keyboard Type

Standard Keyboard08 C6 04 08 00 F2 B4 00 FD 80

Virtual Keyboard08 C6 04 08 00 F2 B4 01 FD 7F

STX and ETX Setting

Forbid08 C6 04 08 00 F2 B7 00 FD 7D

STX(Prefix)08 C6 04 08 00 F2 B7 01 FD 7C

ETX(Suffix 1)08 C6 04 08 00 F2 B7 02 FD 7B

STX(Prefix)+ETX(Suffix 1)08 C6 04 08

63

www.hzgrow.com

00 F2 B7 03 FD 7A

ASCII Control Character Output function keys:08 C6 04 08 00 F2

Output Mode Selection

AD 00 FD 87

Output Ctrl combination key:08 C6 04 08 00 F2 AD 01 FD 86

ALT output control characters:08 C6 04 08 00 F2 AD 02 FD 85

Output EnterDownArrow:08 C6 04 08 00 F2 AD 03 FD 84

1D Code Global Enable Switch

Forbid08 C6 04 08 00 F2 11 00 FE 23 Allow08 C6 04 08 00 F2 11 01 FE 22

2D Code Global Enable Switch

Forbid08 C6 04 08 00 F2 50 00 FD E4 Allow08 C6 04 08 00 F2 50 01 FD E3

All Code Global Enable Switch

Forbid08 C6 04 08 00 F2 90 00 FD A4 Allow08 C6 04 08 00 F2 90 01 FD A3

Hide Header Characters

Forbid08 C6 04 08 00 F2 C6 00 FD 6E

Allow08 C6 04 08 00 F2 C6 01 FD 6D

Hide Middle Characters

Forbid08 C6 04 08 00 F2 C7 00 FD 6D

Allow08 C6 04 08 00 F2 C7 01 FD 6C

Hide Tail Characters

Forbid08 C6 04 08 00 F2 C8 00 FD 6C

Allow08 C6 04 08 00 F2 C8 01 FD 6B

Same Code Delay

1500ms:08 C6 04 08 00 F3 03 0F FE 21

500ms:08 C6 04 08 00 F3 03 05 FE 2B

300ms: 08 C6 04 08 00 F3 03 03 FE 2D

Same Code Delay Quickly Set Up

No delay08 C6 04 08 00 F2 C9 00 FD 6B

Delay 1s08 C6 04 08 00 F2 C9 01 FD 6A

Delay 3s08 C6 04 08 00 F2 C9 03 FD 68

Delay 5s08 C6 04 08 00 F2 C9 05 FD 66

Delay 7s08 C6 04 08 00 F2 C9 07 FD

64

www.hzgrow.com

64

Infinite delay  Forbid Same Code Read08 C6 04 08 00 F2 C9 09 FD 62

Set Multiple Prefixes in SetMultiple Prefixes in succession08

succession

C6 04 08 00 F3 10 00 FE 23

Set Multiple Suffixes in Set Multiple Suffixes in succession08

succession

C6 04 08 00 F3 11 00 FE 22

Finish Setting Multiple Finish Setting Multiple Prefixes Suffixes

Prefixes Suffixes in in succession08 C6 04 08 00 FF F6 00

succession

FD 31

Setting Multiple Suffixes Data Format

Prefixes Data+Multiple Suffixes07 C6 04 08 00 Transfer EB 08 FE 34
Multiple Prefixes+Data07 C6 04 08 00 EB 09 FE 33

Multiple

Prefixes+Data+Multiple

Suffixes07 C6 04 08 00 EB 0A FE 32

Heartbeat Control

Forbid08 C6 04 08 00 F2 CD 00 FD 67

Heartbeat don't need ACK08 C6 04 08 00 F2 CD 01 FD 66

Heartbeat need ACK08 C6 04 08 00 F2 CD 02 FD 65

UPC-A

Read

Forbid07 C6 04 08 00 01 00 FF 26

Allow07 C6 04 08 00 01 01 FF 25

Transmit UPC-A Check Forbid07 C6 04 08 00 28 00 FE FF

Character

Allow07 C6 04 08 00 28 01 FE FE

Extra Code

None(00)07 C6 04 08 00 10 00 FF 17

Allow0107 C6 04 08 00 10 01 FF 16

Automatic differentiation(02)07 C6 04 08 00 10 02 FF 15

Leading Code

None(00)07 C6 04 08 00 22 00 FF 05

System identification0107 C6 04 08 00 22 01 FF 04

65

www.hzgrow.com

Country\System identification(02)  07 C6 04 08 00 22 02 FF 03

UPC-A 2 Bit Extra Code

Allow08 C6 04 08 00 F2 40 01 FD F3

Forbid08 C6 04 08 00 F2 40 00 FD F4

UPC-A 5 Bit Extra Code

Allow08 C6 04 08 00 F2 41 01 FD F2

Forbid08 C6 04 08 00 F2 41 00 FD F3

UPC-A Extra Code Must be Allow08 C6 04 08 00 F2 42 01 FD F1

Identified

Forbid08 C6 04 08 00 F2 42 00 FD F2

UPC-E

Read

Forbid07 C6 04 08 00 02 00 FF 25

Allow07 C6 04 08 00 02 01 FF 24

Transmit UPC-E Check bit Forbid07 C6 04 08 00 29 00 FE FE

Allow07 C6 04 08 00 29 01 FE FD

Extra Code

None(00)07 C6 04 08 00 10 00 FF 17

Allow0107 C6 04 08 00 10 01 FF 16

Automatic differentiation(02)07 C6 04 08 00 10 02 FF 15

Leading Code

None(00)07 C6 04 08 00 23 00 FF 04

System identification0107 C6 04 08 00 23 01 FF 03

Country\System identification(02)  07 C6 04 08 00 23 02 FF 02

UPC-E Turn UPC-A

Forbid07 C6 04 08 00 25 00 FF 02

Allow07 C6 04 08 00 25 01 FF 01

UPC-E 2 Bit Extra Code

Allow08 C6 04 08 00 F2 3D 01 FD F6

Forbid08 C6 04 08 00 F2 3D 00 FD F7

UPC-E 5 Bit Extra Code

Allow08 C6 04 08 00 F2 3E 01 FD F5

Forbid08 C6 04 08 00 F2 3E 00 FD F6

UPC-E Extra Code Must be Allow08 C6 04 08 00 F2 3F 01 FD F4

Identified

Forbid08 C6 04 08 00 F2 3F 00 FD F5

66

www.hzgrow.com

UPC-E1

Forbid08 C6 04 08 00 F2 15 00 FE 1F

Allow08 C6 04 08 00 F2 15 01 FE 1E

EAN-8

Read

Forbid07 C6 04 08 00 04 00 FF 23

Allow07 C6 04 08 00 04 01 FF 22

Extra Code

None(00)07 C6 04 08 00 10 00 FF 17

Allow0107 C6 04 08 00 10 01 FF 16

EAN-8 Zero expansion Forbid07 C6 04 08 00 27 00 FF 00 (EAN-8 Extended toEAN-13) Allow07 C6 04 08 00 27 01 FE FF

EAN-8 2 Bit Extra Code

Allow08 C6 04 08 00 F2 37 01 FD FC

Forbid08 C6 04 08 00 F2 37 00 FD FD

EAN-8 5 Bit Extra Code

Allow08 C6 04 08 00 F2 38 01 FD FB

Forbid08 C6 04 08 00 F2 38 00 FD FC

EAN-8 Extra Code Must be Allow08 C6 04 08 00 F2 39 01 FD FA

Identified

Forbid08 C6 04 08 00 F2 39 00 FD FB

EAN-8 Send Check Bit

Forbid08 C6 04 08 00 F2 80 00 FD B4

Allow08 C6 04 08 00 F2 80 01 FD B3

EAN-13

Read

Forbid07 C6 04 08 00 03 00 FF 24

Allow07 C6 04 08 00 03 01 FF 23

EAN-13 2 Bit Extra Code

Allow08 C6 04 08 00 F2 3A 01 FD F9

Forbid08 C6 04 08 00 F2 3A 00 FD FA

EAN-13 5 Bit Extra Code

Allow08 C6 04 08 00 F2 3B 01 FD F8

Forbid08 C6 04 08 00 F2 3B 00 FD F9

EAN-13 Extra Code Must be Allow08 C6 04 08 00 F2 3C 01 FD F7

Identified

Forbid08 C6 04 08 00 F2 3C 00 FD F8

EAN-13 Send Character

Check Forbid08 C6 04 08 00 F2 16 00 FE 1E Allow08 C6 04 08 00 F2 16 01 FE 1D

67

www.hzgrow.com

Extra Code

None(00)07 C6 04 08 00 10 00 FF 17

Allow0107 C6 04 08 00 10 01 FF 16

Bookland EAN(ISBN)

Read

Forbid07 C6 04 08 00 53 00 FE D4

Allow07 C6 04 08 00 53 01 FE D3

Format

Output 10 Bit:08 C6 04 08 00 F1 40 00 FD F5

Output 13 Bit:08 C6 04 08 00 F1 40 01 FD F4

Code 128 Code system Forbid07 C6 04 08 00 08 00 FF 1F

switch

Allow07 C6 04 08 00 08 01 FF 1E

Code 128 Length

One Single length

060B C6 04 08 00 F5 04 06 F5 05 00 FD 2A

Two Single length

04 and 060B C6 04 08 00 F5 04 06 F5 05 04 FD 26

Within a certain length range

04 to 090B C6 04 08 00 F5 04 04 F5 05 09 FD 23

Any length range

0B C6 04 08 00 F5 04 00 F5 05 00 FD 30

GS1-128 ( UCC/EAN-128) Forbid07 C6 04 08 00 0E 00 FF 19

Allow07 C6 04 08 00 0E 01 FF 18

UCC/EAN-128 Send Check Allow08 C6 04 08 00 F2 36 01 FD FD

Character

Forbid08 C6 04 08 00 F2 36 00 FD FE

UCC/EAN-128 Length

One Single length

060B C6 04 08 00 F5 06 06 F5 07 00 FD 26

Two Single length

04 and 060B C6 04 08 00 F5 06 06 F5 07 04 FD 22

68

www.hzgrow.com

ISBT 128 Code 39 Code 39 Length

Within a certain length range 04 to 090B C6 04 08 00 F5 06 04 F5 07 09 FD 1F
Any length range  0B C6 04 08 00 F5 06 00 F5 07 00 FD 2C
Forbid07 C6 04 08 00 54 00 FE D3 Allow07 C6 04 08 00 54 01 FE D2 Forbid07 C6 04 08 00 00 00 FF 27 Allow07 C6 04 08 00 00 01 FF 26 One Single length Length 06
09 C6 04 08 00 12 06 13 00 FE FA Length 16:
09 C6 04 08 00 12 10 13 00 FE F0 Length14:
09 C6 04 08 00 12 0E 13 00 FE F2 Two Single length 02 and 04
09 C6 04 08 00 12 04 13 02 FE FA 16 and 14
09 C6 04 08 00 12 10 13 0E FE E2 Within a certain length range: 02 to 09
09 C-6 04 08 00 12 02 13 09 FE F5 0x02 to 0x37(55)Default
09 C6 04 08 00 12 02 13 37 FE C7 14 to 15:
09 C6 04 08 00 12 0E 13 0F FE E3 15 to 16:
09 C6 04 08 00 12 0F 13 10 FE E1 Any length range09 C6 04 08 00 12 00 13 00 FE F0

69

www.hzgrow.com

Code 39

Forbid07 C6 04 08 00 30 00 FE F7

Check Bit Verification

Allow07 C6 04 08 00 30 01 FE F6

Send Code 39 Check Bit

Forbid07 C6 04 08 00 2B 00 FE FC

Allow07 C6 04 08 00 2B 01 FE FB

Code 39 Full ASCII

07 C6 04 08 00 11 01 FF 15

Code 39 Character Character

Transmit and

Start Stop

Forbid08 C6 04 08 00 F2 30 00 FE 04 Allow08 C6 04 08 00 F2 30 01 FE 03

Convert Code 39 to Code 32 Forbid07 C6 04 08 00 56 00 FE D1

Italian medical code

Allow07 C6 04 08 00 56 01 FE D0

Code 32 Prefixes

Forbid07 C6 04 08 00 E7 00 FE 40

Allow07 C6 04 08 00 E7 01 FE 3F

Code 39 bigcode Switch

Allow08 C6 04 08 00 F2 27 01 FE 0C

Forbid08 C6 04 08 00 F2 27 00 FE 0D

Code 93

Forbid07 C6 04 08 00 09 00 FF 1E

Allow07 C6 04 08 00 09 01 FF 1D

Code 93 Length

One Single length

0409 C6 04 08 00 1A 041B 00 FE EC

Two Single length

04 and 0609 C6 04 08 00 1A 06 1B 04 FE E6

Within a certain length range:

04 to 0909 C6 04 08 00 1A 04 1B 09 FE E3

Any length range 09 C6 04 08 00 1A 00 1B 00 FE F0

Code 93 Check

Allow08 C6 04 08 00 F2 4A 01 FD E9

Forbid08 C6 04 08 00 F2 4A 00 FD EA

Code 93 Send Check Allow08 C6 04 08 00 F2 4B 01 FD E8

Character

Forbid08 C6 04 08 00 F2 4B 00 FD E9

Code 11

Forbid07 C6 04 08 00 0A 00 FF 1D

70

www.hzgrow.com

Allow07 C6 04 08 00 0A 01 FF 1C

Set Code 11 Length

One Single length

0609 C6 04 08 00 1C 06 1D 00 FE E6

Two Single length

04 and 0609 C6 04 08 00 1C 06 1D 04 FE E2

Within a certain length range:

04 to 0909 C6 04 08 00 1C 04 1D 09 FE DF

Any length range 09 C6 04 08 00 1C 00 1D 00 FE EC

Code 11

None07 C6 04 08 00 34 00 FE F3

Check Bit Verification

1 BIt07 C6 04 08 00 34 01 FE F2

2 Bit07 C6 04 08 00 34 02 FE F1

Send Code 11 Check Bit

Forbid07 C6 04 08 00 2F 00 FE F8

Allow07 C6 04 08 00 2F 01 FE F7

Interleaved 2 of 5/ITF/ Corss Forbid07 C6 04 08 00 06 00 FF 21

25 Code

Allow07 C6 04 08 00 06 01 FF 20

Set Interleaved 2 of 5 Length One Single length

0609 C6 04 08 00 16 06 17 00 FE F2

Two Single length

04 and 0609 C6 04 08 00 16 06 17 04 FE EE

Within a certain length range:

04 to 0909 C6 04 08 00 16 04 17 09 FE EB

Any length range09 C6 04 08 00 16 00 17 00 FE F8

Interleaved 2 of 5 Check Bit Forbid07 C6 04 08 00 31 00 FE F6

Verification

Allow07 C6 04 08 00 31 01 FE F5

Send Interleaved 2 of 5 Forbid07 C6 04 08 00 2C 00 FE FB

Check Bit

Allow07 C6 04 08 00 2C 01 FE FA

71

www.hzgrow.com

Discrete 2 of 5 /Industrial 2 Forbid07 C6 04 08 00 05 00 FF 22

of 5/IND25/Industrial 25

Allow07 C6 04 08 00 05 01 FF 21

Set Discrete 2 of 5 Length One Single length

0609 C6 04 08 00 14 06 15 00 FE F6

Two Single length

04 and 0609 C6 04 08 00 14 06 15 04 FE F2

Within a certain length range

04 to 0909 C6 04 08 00 14 04 15 09 FE EF

Any length range 09 C6 04 08 00 14 00 15 00 FE FC

Discrete 2 of 5 Check

Allow08 C6 04 08 00 F2 48 01 FD EB

Forbid08 C6 04 08 00 F2 48 00 FD EC

Discrete 2 of 5 Send Check Allow08 C6 04 08 00 F2 49 01 FD EA

Character

Forbid08 C6 04 08 00 F2 49 00 FD EB

Matrix 25 matrix 25

Forbid08 C6 04 08 00 F2 20 00 FE 14

Allow08 C6 04 08 00 F2 20 01 FE 13

Matrix 25 Verification

Check

Bit Forbid08 C6 04 08 00 F2 21 00 FE 13 Allow08 C6 04 08 00 F2 21 01 FE 12

Transfer Matrix 25 Check Forbid08 C6 04 08 00 F2 22 00 FE 12

Character

Allow08 C6 04 08 00 F2 22 01 FE 11

Matrix 25 Length

One Single length

060B C6 04 08 00 F5 00 06 F5 01 00 FD 32

Two Single length

04 and 060B C6 04 08 00 F5 00 06 F5 01 04 FD 2E

Within a certain length range:

04 to 090B C6 04 08 00 F5 00 04 F5 01 09 FD 2B

Any length range 

0B C6 04 08 00 F5 00 00 F5 01 00

72

www.hzgrow.com

Standard 25 / IATA 25/Standard 25

FD 38 Forbid08 C6 04 08 00 F2 23 00 FE 11 Allow08 C6 04 08 00 F2 23 01 FE 10

Standard 25

Forbid08 C6 04 08 00 F2 24 00 FE 10

Check Bit Verification

Allow08 C6 04 08 00 F2 24 01 FE 0F

Transfer Standard 25 Check Forbid08 C6 04 08 00 F2 25 00 FE 0F

Character

Allow08 C6 04 08 00 F2 25 01 FE 0E

Standard 25 Length

One Single length

0609 C6 04 08 00 F5 02 06 F5 03 00 FD 2E

Two Single length

04 and 0609 C6 04 08 00 F5 02 06 F5 03 04 FD 2A

Within a certain length range:

04 to 0909 C6 04 08 00 F5 02 04 F5 03 09 FD 27

Any length range 09 C6 04 08 00 F5 02 00 F5 03 00 FD 34

Codabar

Forbid07 C6 04 08 00 07 00 FF 20

Allow07 C6 04 08 00 07 01 FF 1F

Set Codabar Length

One Single length

0409 C6 04 08 00 18 04 19 00 FE F0

Two Single length

09 C6 04 08 00 18 05 19 04 FE EB

Within a certain length range:

04 to 0909 C6 04 08 00 18 04 19 09 FE E7

Any length range 09 C6 04 08 00 18 00 19 00 FE F4

Codabar Check

Allow08 C6 04 08 00 F2 4C 01 FD E7

Forbid08 C6 04 08 00 F2 4C 00 FD E8

73

www.hzgrow.com

Codabar Send Character

Check Allow08 C6 04 08 00 F2 4D 01 FD E6 Forbid08 C6 04 08 00 F2 4D 00 FD E7

NOTIS Transmission Format Forbid07 C6 04 08 00 37 00 FE F0

Allow07 C6 04 08 00 37 01 FE EF

Start Character and End ABCD/ABCD08 C6 04 08 00 F2 31 00

Character Formats

FE 03

ABCD/TN*E08 C6 04 08 00 F2 31 01 FE 02

Set the upper and lower Upper Case08 C6 04 08 00 F2 32 00

case of the start and end FE 02

characters

Lower Case08 C6 04 08 00 F2 32 01

FE 01

MSI /MSI PLESSEY

Forbid07 C6 04 08 00 0B 00 FF 1C

Allow07 C6 04 08 00 0B 01 FF 1B

Set MSI Length

One Single length

0409 C6 04 08 00 1E 04 1F 00 FE E4

Two Single length

04 and 0509 C6 04 08 00 1E 05 1F 04 FE DF

Within a certain length range:

02 to 0909 C6 04 08 00 1E 02 1F 09 FE DD

Any length range 09 C6 04 08 00 1E 00 1F 00 FE E8

MSI Check Bit

1 Bit: 07 C6 04 08 00 32 00 FE F5

2 Bit:07 C6 04 08 00 32 01 FE F4

Send MSI Check Bit

Forbid07 C6 04 08 00 2E 00 FE F9

Allow07 C6 04 08 00 2E 01 FE F8

GS1 DataBar(RSS) 14

Forbid08 C6 04 08 00 F0 52 00 FD E4

Allow08 C6 04 08 00 F0 52 01 FD E3

PDF417

Allow07 C6 04 08 00 0F 01 FF 17

Forbid07 C6 04 08 00 0F 00 FF 18

Read More Yards

Only Read Single Code: 08 C6 04 08

74

www.hzgrow.com

00 F2 60 00 FD D4

Only read Dicode: 08 C6 04 08 00 F2 60 01 FD D3

Single and Dicode can be recognized: 08 C6 04 08 00 F2 60 02 FD D2

Forward and Backward Only read Forward: 08 C6 04 08 00 F2

Reading

61 00 FD D3

Only read Backward: 08 C6 04 08 00 F2 61 01 FD D2

Forward and Backward both can read: 08 C6 04 08 00 F2 61 02 FD D1

QRCode

Allow08 C6 04 08 00 F0 25 01 FE 10

Forbid08 C6 04 08 00 F0 25 00 FE 11

Read More Yards

Only Read Single Code: 08 C6 04 08 00 F2 65 00 FD CF

Only read Dicode: 08 C6 04 08 00 F2 65 01 FD CE

Single and Dicode can be recognized: 08 C6 04 08 00 F2 65 02 FD CD

QR Forward and Backward Only read Forward08 C6 04 08 00 F2

Reading

67 00 FD CD

Only read Backward 08 C6 04 08 00 F2 67 01 FD CC

Forward and Backward both can read 08 C6 04 08 00 F2 67 02 FD CB

MicroQRCode

Allow08 C6 04 08 00 F1 3D 01 FD F7

Forbid08 C6 04 08 00 F1 3D 00 FD F8

DataMatrix

Allow08 C6 04 08 00 F0 24 01 FE 11

Forbid08 C6 04 08 00 F0 24 00 FE 12

Read More Yards

Only Read Single Code: 08 C6 04 08 00 F2 6A 00 FD CA

Only read Dicode: 08 C6 04 08 00 F2 6A 01 FD C9

Single and Dicode can be recognized: 08 C6 04 08 00 F2 6A 02 FD C8

75

www.hzgrow.com

Forward and Backward Only read Forward: 08 C6 04 08 00 F2

Reading

6B 00 FD C9

Only read Backward: 08 C6 04 08 00 F2 6B 01 FD C8

Forward and Backward both can read: 08 C6 04 08 00 F2 6B 02 FD C7

MaxiCode

Forbid08 C6 04 08 00 F0 26 00 FE 10

Allow08 C6 04 08 00 F0 26 01 FE 0F

Aztec

Forbid08 C6 04 08 00 F0 28 00 FE 0E

Allow08 C6 04 08 00 F0 28 01 FE 0D

Han Xin Code

Forbid08 C6 04 08 00 F0 2F 00 FE 07

Allow08 C6 04 08 00 F0 2F 01 FE 06

Read More Yards

Only Read Single Code: 08 C6 04 08 00 F2 70 00 FD C4

Only read Dicode: 08 C6 04 08 00 F2 70 01 FD C3

Single and Dicode can be recognized: 08 C6 04 08 00 F2 70 02 FD C2

Forward and Backward Only read Forward: 08 C6 04 08 00 F2

Reading

71 00 FD C3

Only read Backward: 08 C6 04 08 00 F2 71 01 FD C2

Forward and Backward both can read: 08 C6 04 08 00 F2 71 02 FD C1

Brazil Bank Code

Allow08 C6 04 08 00 F2 28 01 FE 0B

Forbid08 C6 04 08 00 F2 28 00 FE 0C

Allow/Forbid COMPOSITE Forbid08 C6 04 08 00 F2 17 00 FE 1D

Allow08 C6 04 08 00 F2 17 01 FE 1C

76

www.hzgrow.com

Appendix 7: Mirror
QR Mirror
*Forbid
DM Mirror
*Forbid

Allow Allow

77

www.hzgrow.com