converter tests with system LO, and manual mode to simulate the legacy NF meter. Vector modulation analysis. Digital Demodulation. N9054EM0E. Performs ...
N9020B MXA X-Series Signal Analyzer, Multi-touch This configuration guide will help you determine which performance options, measurement applications, accessories, and services to include with your new multi-touch MXA or to add as upgrades to an existing MXA. CONFIGURATION GUIDE Configure Your MXA Signal Analyzer This step-by-step process will help you configure your new Keysight Technologies, Inc. MXA X-Series signal analyzer. Tailor the performance to meet your requirements. Included in base product Standard options and accessories come with the MXA base model at no additional charge and do not need to be ordered. They include: Spectrum analyzer measurement application Quad-core, high-performance processor, 16 GB RAM, with flash calibration file memory Frequency reference Mechanical attenuator 25 MHz analysis bandwidth Microsoft Windows 10 operating system Benchtop configuration Multi-language user interface User guide Power cord Front panel cover for protection during transit Get More Information For a summary of specifications, refer to the N9020B MXA data sheet (literature number 5992-1255EN). A full set of specifications are available in the N9020B MXA Signal Analyzer Specification Guide at www.keysight.com/ find/mxa_specifications. Step 1. Select maximum frequency range (required option) Description Option number Additional information Frequency range, 10 Hz to 3.6 GHz N9020B-503 Frequency range, 10 Hz to 8.4 GHz N9020B-508 Frequency range, 10 Hz to 13.6 GHz N9020B-513 Frequency range, 10 Hz to 26.5 GHz N9020B-526 Frequency range, 10 Hz to 32 GHz N9020B-532 Frequency range, 10 Hz to 44 GHz N9020B-544 Frequency range, 10 Hz to 50 GHz N9020B-550 Step 2. Add a preamplifier Description Option number Additional information Preamplifiers improve the noise floor for low-level signal detection Preamplifier, 100 kHz to 3.6 GHz N9020B-P03 Compatible with frequency range options: N9020B-503, N9020B-508, N9020B-513, N9020B-526, N9020B-532, N9020B-544 and N9020B-550 Preamplifier, 100 kHz to 8.4 GHz N9020B-P08 Compatible with frequency range options: N9020B-508, N9020B-513, N9020B-526, N9020B-532, N9020B-544 and N9020B-550 Preamplifier, 100 kHz to 13.6 GHz N9020B-P13 Compatible with frequency range options: N9020B-513, N9020B-526, N9020B-532, N9020B-544 and N9020B-550 Preamplifier, 100 kHz to 26.5 GHz N9020B-P26 Compatible with frequency range options: N9020B-526, N9020B-532, N9020B-544 and N9020B-550 Preamplifier, 100 kHz to 32 GHz N9020B-P32 Compatible with frequency range options: N9020B-532 Preamplifier, 100 kHz to 44 GHz N9020B-P44 Compatible with frequency range options: N9020B-544 Preamplifier, 100 kHz to 50 GHz N9020B-P50 Compatible with frequency range option: N9020B-550 Step 3. Choose frequency reference Description Option number Additional information Frequency reference Standard Aging rate: ± 1 x 106/year Precision frequency reference N9020B-PFR Reduces frequency drift for more accurate measurements Aging rate: ± 1 x 107/year Step 4. Choose an attenuator Description Option number Additional information Mechanical attenuator Standard 2 dB steps, 0 to 70 dB Electronic attenuator up to 3.6 GHz N9020B-EA3 In addition to the mechanical attenuator; 1 dB steps, 0 to 24 dB Find us at www.keysight.com Page 2 Step 5. Choose analysis bandwidth Description Option number Additional information 25 MHz analysis bandwidth Standard Useful for most cellular communications, wireless connectivity, and audio/video broadcasting measurement applications; licensed as N9020B-B25 40 MHz analysis bandwidth N9020B-B40 Extends the analysis bandwidth to 40 MHz (Option MPB required for measurements at frequency > 3.6 GHz); included in B85, B1A, or B1X; also enables fast sweep capability licensed as N9020B-FS1 and N9020B-FS2; if Option BBA is installed, provides 40 MHz per channel baseband bandwidth 85 MHz analysis bandwidth N9020B-B85 Extends the analysis bandwidth to 85 MHz (Option MPB required for measurements > 3.6 GHz); also enables fast sweep capability licensed as N9020B-FS1 and N9020B-FS2; not compatible with Option BBA 125 MHz analysis bandwidth N9020B-B1A Extends the analysis bandwidth to 125 MHz (Option MPB required for measurements > 3.6 GHz); also enables fast sweep capability licensed as N9020B-FS1 and N9020B-FS2; not compatible with Option BBA 160 MHz analysis bandwidth N9020B-B1X Extends the analysis bandwidth to 160 MHz (Option MPB required for measurements > 3.6 GHz); also enables fast sweep capability licensed as N9020B-FS1 and N9020B-FS2; not compatible with Option BBA Microwave preselector bypass N9020B-MPB Required for wide analysis bandwidth measurements with Option B40, B85, B1A, or B1X at frequency > 3.6 GHz; also enables fast sweep capability licensed as N9020B-FS1 and N9020B-FS2 Step 6. Choose performance options Description Option number Additional information Digital processor with 2 GB capture N9020B-DP2 Comes standard with Option B40, B85, B1A, or B1X; also enables fast sweep capability memory licensed as N9020B-FS1 and N9020B-FS2 Digital processor with 4 GB capture N9020B-DP4 Comes standard with Option B85, B1A, or B1X in instrument models with serial number memory prefix MY/SG/US5608; also enables fast sweep capability licensed as N9020B-FS1 and N9020B-FS2 I/Q baseband inputs, analog N9020B-BBA Single-ended/differential, 50 /1 M impedance; not compatible with Option B85, B1A, B1X, 532, 544, or 550 External mixing N9020B-EXM Connects with Keysight and third party mixers 1 to extend frequency coverage up to 1.1 THz; single port for LO out and IF in (SMA female) Noise floor extension N9020B-NF2 Improves analyzer's DANL performance (instrument alignment based processes) Step 7. Add real-time spectrum analysis Note: Keysight offers 4 license types for the measurement applications and instrument features, in 2 license terms: Perpetual or Time-based. License types: Node-locked: Allows you to use the license on one instrument/computer at a time Transportable: Allows you to use the license on one instrument/computer at a time. This license may be transferred to another instrument/computer using Keysight's online tool Floating: Allows you to access the license on the networked instruments/computers from a server, one at a time. For concurrent access, multiple licenses may be purchased USB Portable: Allows you to access the license from one instrument/computer to another by end-user only with certified USB dongle, purchased separately License terms: Perpetual: License can be used in perpetuity. For perpetual license holders, a separate support contract is required to access Keysight technical support and software updates Time-based: License is time limited to a defined period, such as 12-months. A valid support contract is included in the pricing for time-based licenses. For detailed information, we strongly recommend you visit the X-Series measurement application collection page: www.keysight.com/find/xseriesapps Description Option number Additional information Real-time analysis up to maximum N9020RT1B Includes frequency mask trigger (FMT) and time qualified trigger (TQT); minimum 17.3 s available BW, Basic Detection signal duration for 100% probability of intercept (POI); requires Option B85, B1A, or B1X, which determines maximum real-time bandwidth; also supports Option EXM Real-time analysis up to maximum N9020RT2B Includes frequency mask trigger (FMT) and time qualified trigger (TQT); minimum 3.6 s available BW, Optimum Detection signal duration for 100% probability of intercept (POI); requires Option B85, B1A, or B1X, which determines maximum real-time bandwidth; also supports Option EXM Frequency mask trigger, basic N90EMFT1B Enables frequency mask triggering with N9067EM0E pulse application and 89600 VSA detection software to detect signals as short as 17.3 s duration; included in N9020RT1B (Option RT1); requires bandwidth options B85, B1A, or B1X 1. When used with the Keysight 11970 Series external mixers, an external diplexer is required. Recommended diplexer can be purchased from Keysight as N9029AE13, or from OML Inc. as DPL313B. Find us at www.keysight.com Page 3 Step 7. Add real-time spectrum analysis (Continued) Description Option number Additional information Frequency mask trigger, optimum detection N90EMFT2B Enables frequency mask triggering with N9067EM0E pulse application and 89600 VSA software to detect signals as short as 3.6 s duration; included in N9020RT2B (Option RT2); requires bandwidth options B85, B1A, or B1X Step 8. Add optional features Description Option number Additional information Enhanced display package N90EMEDPB Includes spectrogram, trace zoom, and zone span Basic EMI precompliance N90EMEMCB Perform basic EMI precompliance measurements with CISPR 16-1-1 detectors and bandwidths; tune and listen, and measure at marker are also available Time domain scan N90EMTDSB Improves scan speed for EMC pre-compliance tests; requires N6141EM0E EMC pre-compliance measurement application and Option DP2, or B40 (or wider bandwidth option) External source control N90EMESCB External source control for selected Keysight EXG, MXG, and PSG signal generators; supports external mixing; includes 3 BNC cables and 1 cross-over LAN cable Fast power up to available maximum analysis bandwidth N90EMFP2B Accelerates power measurements such as ACPR; requires Option B40, B85, B1A, or B1X Resolution bandwidth extended N90EMRBEB Extends the maximum RBW in Zero Span; requires option B85, B1A, or B1X Step 9. Choose operating system Description Option number Additional information Windows 10 operating system Standard Licensed as N9020B-W10 Step 10. Add security features Description Option number Additional information Additional removable solid-state drive N9020B-SS1 Provides a fully-imaged, removable solid-state drive in addition to the one installed in the instrument, with Windows 10 operating system Exclude launch program N9020B-SF1 Prevents the launching of Windows programs from the instrument application Prohibit saving results N9020B-SF2 Prevents the saving/recall of measurement results or user configurations to/from instrument's data storage Step 11. Add rear panel output utilities Description Option number Additional information Second IF output N9020B-CR3 Wideband IF out; center frequency depends on IF path; output on Aux IF connector at rear panel Arbitrary IF output N9020B-CRP IF out 10 to 75 MHz (in 500 kHz steps); output on Aux IF connector at rear panel Y-axis screen video output N9020B-YAS Screen video (0-1 volt open circuit) on rear panel analog out Real-time link Standard when B40 or The LVDS connector allows MXA to connect to X-COM data recorder for data DP2 is ordered streaming (up to 40 MHz BW), and to the N5106A PXB baseband generator and channel emulator; requires Option B40 or DP2; licensed as N9020B-RTL Step 12. Choose measurement application or software and license type Note: Keysight offers 4 license types for the measurement applications and instrument features, in 2 license terms: Perpetual or Time-based. License types: Node-locked: Allows you to use the license on one instrument/computer at a time Transportable: Allows you to use the license on one instrument/computer at a time. This license may be transferred to another instrument/computer using Keysight's online tool Floating: Allows you to access the license on the networked instruments/computers from a server, one at a time. For concurrent access, multiple licenses may be purchased USB Portable: Allows you to access the license from one instrument/computer to another by end-user only with certified USB dongle, purchased separately License terms: Perpetual: License can be used in perpetuity. For perpetual license holders, a separate support contract is required to access Keysight technical support and software updates Time-based: License is time limited to a defined period, such as 12-months. A valid support contract is included in the pricing for time-based licenses. For detailed information, we strongly recommend you visit the X-Series measurement application collection page: www.keysight.com/find/xseriesapps Description Option number Additional information General purpose Spectrum analyzer Standard Traditional spectrum analysis plus many new and enhanced functions; power measurements based on industry specifications; licensed as N9060EM1E Analog demodulation N9063EM0E Adds one-button measurement for AM/FM/PM demodulation with metrics, tune and listen, and AF spectrum; supports audio output (output voltage proportional to frequency deviation). FM Stereo and RDS are included Find us at www.keysight.com Page 4 Step 12. Choose measurement application or software and license type (Continued) Description Option number Additional information General purpose (Continued) Phase noise N9068EM0E Adds one-button measurements for analyzing phase noise in frequency domain (log plot) and time domain (spot frequency), supports external mixing Noise figure N9069EM0E (requires preamplifier) Adds one-button measurements for noise figure, gain, and related metrics; requires preamplifier to meet specifications; works with Keysight U1831C USB noise source, N400xA Series smart noise sources and 346 Series noise sources; supports U7227 USB external preamplifiers Includes the advanced NF measurement features including external LO control over GPIB/LAN/USB, multi-stage converter tests with system LO, and manual mode to simulate the legacy NF meter Vector modulation analysis Digital Demodulation N9054EM0E Performs one-button flexible modulation analysis measurements with FSK, PSK, QAM, MSK, ASK, APSK, VSB etc. and poprular format preset Vector modulation analysis Custom OFDM N9054EM1E Performs one-button custom OFDM modulation analysis measurement with user-defined settings or recalling 89600 VSA or Signal Studio output files Pulse analysis N9067EM0E Characterize pulsed RF signals in the time domain, with phase, frequency and statistical analysis of large pulse sets; enables fixed and variable length gated acquisition for capturing pulses of varying pulse width and PRI (requires 4 GB capture memory Option DP4) EMI N6141EM0E Performs pre-compliance conducted and radiated emission measurements Remote language compatibility N9061EM0E Adds capability to emulate HP/Agilent 8566/68 and 856xE/EC spectrum analyzers SCPI command language compatibility N9062EM0E Adds capability to emulate the R&S FSP/FSU/FSL/FSV/FSW spectrum analyzers or ESU EMI receiver MATLAB software N6171A Cellular communications GSM/EDGE/Evo N9071EM0E Standard-based, one-button GSM/EDGE/EDGE Evolution measurements N9071EMXE Adds single acquisition combined measurement, a SCPI-command based measurement optimized for high-volume, high-throughput manufacturing; requires N9071EM0E; not compatible with Options DP2, B40, B85, B1A, B1X, or MPB W-CDMA/HSPA+ N9073EM0E Standard-based, one-button W-CDMA, HSPA and HSPA+ measurements; supports analog baseband analysis with Option BBA (BBIQ inputs) N9073EMXE Adds single acquisition combined measurement, a SCPI-command based measurement optimized for high-volume, high-throughput manufacturing; requires N9073EM0E; not compatible with Options DP2, B40, B85, B1A, B1X, or MPB LTE/LTE-Advanced FDD N9080EM0E Standard-based, one-button LTE/LTE-Advanced FDD measurements NB-IoT & eMTC FDD N9080EM3E Standard-based, one-button NB-IoT/eMTC measurements LTE V2X N9080EM4E Standard-based, one-button LTE-V2X transmitter measurements LTE/LTE-Advanced TDD N9082EM0E Standard-based, one-button LTE/LTE-Advanced TDD measurements Multi-standard radio N9083EM0E Standard -based, one-button MSR measurements on any combination of LTE-FDD, LTE-TDD, W-CDMA/HSPA/HSPA+, GSM/EDGE/EDGE Evo, cdma2000, 1xEV-DO and TD-SCDMA signals 5G NR (New Radio) N9085EM0E Standard-based, one-button 5G NR (New Radio) downlink and uplink measurements; Firmware above A.20.25; Requires option B1A or B1X Wireless connectivity WLAN 802.11a/b/g/j/p/n/ af/ah N9077EM0E Standard-based, one-button 802.11a/b/g/j/p/n/af/ah measurement WLAN 802.11ac/ax Bluetooth® N9077EM1E N9081EM0E Standard-based, one-button 802.11ac/ax measurement Standard-based, one-button Bluetooth (BR/EDR, Low Energy 4.0/4.2 and Bluetooth 5) measurements Short range comm and IoT N9084EM0E Standard-based, one-button LoRa CSS measurement, 802.15.4 for ZigBee measurement and G.9959 for Z-Wave measurement Find us at www.keysight.com Page 5 Step 13. Choose 89600 VSA software Description Option number Additional information Basic vector signal analysis 89601200C Provides the tools and user interface that make up the 89600 VSA software including time and and hardware connectivity (required core frequency domain measurement, hardware connectivity, recordings and playback option) Channel quality modulation analysis General purpose Digital demodulation analysis 89601AYAC Analysis of >40 modulation formats, including custom APSK and presets for communication formats like GSM/EDGE, ZigBee FSK, Bluetooth® BR, APCO25 and SOQPSK Proprietary and pre-standard, customized IQ constellation signals TEDS modulation analysis Channel response measurements such as phase/magnitude response and multi-tone group delay Custom OFDM modulation 89601BHFC Proprietary and pre-standard OFDM formats analysis Cellular communication 5G NR modulation analysis 89601BHNC 5G NR modulation analysis Pre-5G modulation analysis LTE/LTE-A FDD modulation 89601BHGC LTE FDD modulation analysis analysis LTE-Advanced FDD modulation analysis LTE/LTE-A TDD modulation 89601BHHC LTE TDD modulation analysis analysis LTE-Advanced TDD modulation analysis 3G modulation analysis bundle 89601B7NC W-CDMA/HSPA+ modulation analysis TD-SCDMA/HSPA modulation analysis cdma2000 modulation analysis 1xEV-DO and 1xEV-DV modulation analysis Wireless connectivity Wireless connectivity 89601B7RC WLAN 802.11a/b/g/j/p modulation analysis modulation analysis WiMax modulation analysis High throughput WLAN 89601BHXC WLAN 802.11n/ac modulation analysis modulation analysis WLAN 802.11ax modulation analysis IoT modulation analysis 89601BHTC NB-IoT modulation analysis RFID modulation analysis Radar analysis Pulse analysis 89601BHQC Pulsed modulated radar signal analysis FMCW radar analysis 89601BHPC For multi-chirp linear FM modulated signals or automotive radar Other standard formats DOCSIS modulation analysis 89601BHMC DOCSIS3.1 downstream and upstream modulation analysis Multi-vendor hardware 89601301C Connect multi-vendor hardware for modulation analysis connectivity Step 14. Choose physical instrument configuration Description Option number Additional information Bench top configuration Standard Provides two side carrying straps, four rear feet, and four bottom feet with a tilt stand; a front panel protective cover is included Portable configuration N9020B-PRC Provides a convenient, pivoting carrying handle as well as rubber protective corners and end guards; this configuration is intended for applications requiring more rugged packaging, such as in the field Find us at www.keysight.com Page 6 Step 15. Choose accessories Description User guide Option number Standard Front-panel protective cover Power cord Adapter, 2.4 mm (F) to 2.9 mm (F) Adapter, 2.4 mm (F) to 2.4 mm (F) Documentation DVD Rack mount Front handles Rack mount with handles Rack slide USB DVD-ROM/CD-R/RW drive Mouse, USB interface Minimum loss pad, 50 to 75 (type-N to BNC) Standard Standard Standard Standard N9060EM1E-ABA 1CM113A 1CN103A 1CP105A 1CR013A 1DVR001A 1MSE001A MLP001A V-band waveguide harmonic mixer, 50 to 75 GHz Extended V-band waveguide harmonic mixer, 50 to 80 GHz E-band waveguide harmonic mixer, 60 to 90 GHz W-band waveguide harmonic mixer, 75 to 110 GHz E-band waveguide harmonic mixer, 60 to 90 GHz Extended E-band waveguide harmonic mixer, 55 to 90 GHz V-band waveguide harmonic mixer, 55 to 75 GHz W-band waveguide harmonic mixer, 75 to 110 GHz 26 to 40 GHz waveguide harmonic mixer 33 to 50 GHz waveguide harmonic mixer 40 to 60 GHz waveguide harmonic mixer 50 to 75 GHz waveguide harmonic mixer 75 to 110 GHz waveguide harmonic mixer LO/IF diplexer 90 to 140 GHz OML harmonic mixer 110 to 170 GHz OML harmonic mixer 140 to 220 GHz OML harmonic mixer 220 to 325 GHz OML harmonic mixer 50 to 75 GHz frequency extension module 60 to 90 GHz frequency extension module 75 to 110 GHz frequency extension module 90 to 140 GHz frequency extension module 110 to 170 GHz frequency extension module 140 to 220 GHz frequency extension module 220 to 330 GHz frequency extension module 325 to 500 GHz frequency extension module 550 to 750 GHz frequency extension module 750 to 1100 GHz frequency extension module Power supply for VDI module USB external preamplifier, 10 MHz to 4 GHz USB external preamplifier, 0.1 to 26.5 GHz USB external preamplifier, 2 to 50 GHz M1970V-001 M1970V-002 M1970E M1970W M1971E-001 M1971E-003 M1971V M1971W 11970A 11970Q 11970U 11970V 11970W N9029AE13 N9029AE08 N9029AE06 N9029AE05 N9029AE03 N9029AV15 N9029AV12 N9029AV10 N9029AV08 N9029AV06 N9029AV05 N9029AV03 N9029AV02 N9029AV1B N9029AV01 N5262VDI-175 U7227A U7227C U7227F Additional information US English localization All user documentation is included in the MXA's embedded, context-sensitive help system User documentation can be downloaded from: www.keysight.com/find/mxa_manuals Dependent upon the region of use Ship standard only for Option 532, 544 and 550 Ship standard only for Option 544 and 550 US - English localization Adds rack mount flanges to the MXA Adds front handles to the MXA Adds rack mount flanges and handles to the MXA Adds a non-tilting rack slide to the MXA Enhances the usability of the Windows operating system 50 type-N male to 75 BNC female adapter Frequency range: 9 MHz to 2 GHz Input/output return loss: 20 and 11 dB Insertion loss: 5.7 dB Requires Option EXM; USB mixer with smart features Requires Option EXM; USB mixer with smart features Requires Option EXM; USB mixer with smart features Requires Option EXM; USB mixer with smart features Requires Option EXM; USB mixer with smart features and 3 signal paths Requires Option EXM; USB mixer with smart features and 3 signal paths Requires Option EXM; USB mixer with smart features and 3 signal paths Requires Option EXM; USB mixer with smart features and 3 signal paths Requires Option EXM and N9029AE13 diplexer Requires Option EXM and N9029AE13 diplexer Requires Option EXM and N9029AE13 diplexer Requires Option EXM and N9029AE13 diplexer Requires Option EXM and N9029AE13 diplexer Ordering convenience; required for 11970 Series external mixers Ordering convenience; requires Option EXM Ordering convenience; requires Option EXM Ordering convenience; requires Option EXM Ordering convenience; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM Required for the N9029AVxx VDI module For more information on accessories go to: www.keysight.com/find/accessories Find us at www.keysight.com Page 7 Step 16. Add calibration, technical training, support, and upgrade services Description Option number Additional information Commercial calibration certificate with test data N9020B-UK6 Calibration certificate only available at time of instrument purchase; only provides measurement results Keysight Calibration + Uncertainties + N9020B-AMG Provides ISO 17025A accredited calibration from factory Guardbanding (accredited cal) ANSI Z540-1-1994 Calibration N9020B-A6J Provides ANSI Z540 compliant calibration from factory Calibration Assurance Plan, R-50C-011-3 Return-to-Keysight, 3 years Calibration Assurance Plan, Return-to-Keysight, 5 years Calibration Assurance Plan, Return-to-Keysight, 7 years R-50C-011-5 R-50C-011-7 Keysight tests your instrument against its original specifications and automatically makes adjustments if outside of specified parameters; preand post-adjustment measurement data reports also provided Calibration Assurance Plan, R-50C-011-10 Return-to-Keysight, 10 years Service: Remote scheduled productivity PS-S10-100 Hourly phone-in technical support service designed to help you understand assistance and operate your equipment through convenient phone and Web access Service: 1-day start-up assistance PS-S20-01 Training on how to operate your instrument effectively (recommended) Service: Productivity assistance PS-S20-100 Daily instrument and application consulting using your equipment and device under test Service: custom engineering service PS-X10-100 Application-specific technical assistance Other calibration options may be available; for more information on calibration go to: www.keysight.com/find/calibration For more information on training and application support services go to: www.keysight.com/find/training MXA bench top configuration Find us at www.keysight.com Page 8 Instrument Upgrades Fast license-key upgrades for performance options that do not require additional hardware: 1. Place an order for the upgrade with Keysight and request to receive the option upgrade entitlement certificate and a one-time software upgrade license through email 2. Redeem the certificate through the Web by following the instructions on the certificate 3. Install the license file and latest software in the MXA 4. Begin using the new capability 1, 2 You can upgrade! Options can be added after your initial purchase. Installation and testing information is available at: www.keysight.com/find/mxa_upgrades Upgrades for analysis bandwidth depend on the vintage of the instrument and the options already installed. More than one option may be required to achieve desired wider analysis bandwidth. Use our web-based calculator to find the upgrade options you may need: www.keysight.com/find/BW-selector All of our X-Series application options are license-key upgradeable. Description Increase frequency from 3.6 to 8.4 GHz Increase frequency from 3.6 to 13.6 GHz Increase frequency from 3.6 to 26.5 GHz Increase frequency from 3.6 to 32 GHz Increase frequency from 3.6 to 44 GHz Increase frequency from 8.4 to 13.6 GHz Increase frequency from 8.4 to 26.5 GHz Increase frequency from 8.4 to 32 GHz Increase frequency from 8.4 to 44 GHz Increase frequency from 13.6 to 26.5 GHz Increase frequency from 13.6 to 32 GHz Increase frequency from 13.6 to 44 GHz Increase frequency from 26.5 to 32 GHz Increase frequency from 26.5 to 44 GHz Increase frequency from 32 to 44 GHz Increase frequency from 3.6 to 50 GHz Increase frequency from 8.4 to 50 GHz Increase frequency from 13.6 to 50 GHz Increase frequency from 26.5 to 50 GHz Increase frequency from 32 to 50 GHz Increase frequency from 44 to 50 GHz Increase analysis bandwidth from 25 MHz to 40 MHz (for RF and microwave MXA) Upgrade number N9020BU-F01 N9020BU-F02 N9020BU-F03 N9020BU-F04 N9020BU-F05 N9020BU-F06 N9020BU-F07 N9020BU-F08 N9020BU-F09 N9020BU-F10 N9020BU-F11 N9020BU-F12 N9020BU-F13 N9020BU-F14 N9020BU-F15 N9020BU-F16 N9020BU-F17 N9020BU-F18 N9020BU-F19 N9020BU-F20 N9020BU-F21 N9020BU-B40 Requirements (MXA must already include the following) 503 503 503 503 503 508 508 508 508 513 513 513 526 526 532 503 508 513 526 532 544 503, 508, 513, or 526 Increase analysis bandwidth from 25 MHz to 40 MHz (for millimeter wave MXA) Increase analysis bandwidth from 25 MHz to 85 MHz (for RF and microwave MXA) N9020BU-BUN N9020BU-B85 532, 544, 550 503, 508, 513, or 526 Increase analysis bandwidth from 25 MHz to 85 MHz (for millimeter wave MXA) Increase analysis bandwidth from 40 MHz to 85 MHz N9020BU-BUD N9020BU-BU1 532, 544, 550 B40 Additional information Includes hardware and license key; adds microwave preselector bypass for instruments with Option 508, 513, or 526; also enables 40 MHz per channel baseband bandwidth if Option BBA is installed Includes hardware and license key; also add microwave preselector bypass Includes hardware and license key; also add microwave preselector bypass for instruments with Option 508, 513, or 526 and license for Option DP4; not compatible with Option BBA Includes hardware and license key; also add microwave preselector bypass and license for Option DP4 Includes hardware and license key; add license for Option DP4; not compatible with Option BBA 1. At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was verified to be within its warranted specifications. Within two years of the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment or verification testing. 2. If this analyzer has been adjusted as part of a repair or calibration during its two years, or if the analyzer is more than two years old, additional adjustment and performance verification tests are required to ensure that some newly installed options are functioning properly. However, the completion of these tests does not guarantee that the analyzer meets all warranted specifications. Find us at www.keysight.com Page 9 Description Increase analysis bandwidth from 25 to 125 MHz (for RF and microwave MXA) Increase analysis bandwidth from 25 MHz to 125 MHz (for millimeter wave MXA) Increase analysis bandwidth from 40 to 125 MHz Increase analysis bandwidth from 85 to 125 MHz Increase analysis bandwidth from 25 to 160 MHz (for RF and microwave MXA) Increase analysis bandwidth from 25 MHz to 160 MHz (for millimeter wave MXA) Increase analysis bandwidth from 40 to 160 MHz Increase analysis bandwidth from 85 to 160 MHz Increase analysis bandwidth from 125 to 160 MHz Digital processor with 4 GB capture memory for instruments with serial number prefixes < MY/SG/US5608 Upgrade to the precision frequency reference Add an electronic attenuator, 3.6 GHz Add enhanced fast sweep speed Add preamplifier, 3.6 GHz Add preamplifier, 8.4 GHz Add preamplifier, 13.6 GHz Add preamplifier, 26.5 GHz Add preamplifier, 32 GHz Add preamplifier, 44 GHz Add preamplifier, 50 GHz Add analog baseband IQ inputs Add external mixing Add fast power up to available maximum analysis bandwidth Add noise floor extension Add security features, exclude launch program Add security features, prohibit saving results Add removable solid-state drive (SSD) Add second IF output Upgrade number N9020BU-B1A N9020BU-BUE N9020BU-BU2 N9020BU-BU6 N9020BU-B1X N9020BU-BUL N9020BU-BU3 N9020BU-BU7 N9020BU-BUA N9020BU-DP4 N9020BU-PFR N9020BU-EA3 N9020BU-FS2 N9020BU-P03 N9020BU-P08 N9020BU-P13 N9020BU-P26 N9020BU-P32 N9020BU-P44 N9020BU-P50 N9020BU-BBA N9020BU-EXM N9020BU-FP2 N9020BU-NF2 N9020BU-SF1 N9020BU-SF2 N9020BU-SS1 N9020BU-CR3 Requirements (MXA must already include the following) 503, 508, 513, or 526 532, 544, 550 B40 B85 503, 508, 513, or 526 532, 544, 550 B40 B85 B1A B85, B1A, or B1X None None DP2, B40, or MPB None 508, 513, 526, 532, 544, or 550 513, 526, 532, 544, or 550 526, 532, 544, or 550 532 544 550 None None B40, or B85, B1A, B1X None None None None B40, B85, B1A, B1X, DP2, MPB, CRP, 532, 544 or 550 Additional information Includes hardware and license key; also add microwave preselector bypass for instruments with Option 508, 513, or 526 and license for Option DP4, not compatible with Option BBA Includes hardware and license key; also add microwave preselector bypass and license for Option DP4 Includes hardware and license key; add license for Option DP4; not compatible with Option BBA License key only Includes hardware and license key; also add microwave preselector bypass for instruments with Option 508, 513, or 526 and license for Option DP4, not compatible with Option BBA Includes hardware and license key; also add microwave preselector bypass and license for Option DP4 Includes hardware and license key; add license for Option DP4; not compatible with Option BBA License key only License key only Includes hardware and license key Not compatible with Option 503 Not compatible with Options 503, 508 Not compatible with Options 503, 508, 513 Only compatible with Option 532 Only compatible with Option 544 Only compatible with Option 550 Not compatible with Options B85, B1A, B1X, 532, 544, 550 Includes hardware and license key For fast power measurements such as ACPR; Also orderable at N90EMFP2B (requires F/W revision A.21.04 onward) Instrument alignment based Prevents the launching of Windows programs from the instrument application Prevents the saving/recall of measurement results or user configurations to/from instrument's data storage Provides additional, removable solid-state drive, with Windows 10 operating system Find us at www.keysight.com Page 10 Description Upgrade number Add arbitrary IF output Add second IF output and arbitrary IF output N9020BU-CRP N9020BU-HL3 Add Y-axis screen video output Upgrade operating system to Windows 10 N9020BU-YAS N9020BU-SS1 Upgrade to quad-core, high-performance processor, 16 GB RAM, with flash calibration file memory Rack mount and handle kit Front handle kit Rack mount kit Rack slide kit Portable configuration Minimum loss pad, 50 to 75 (type-N to BNC) Korean version of Getting Started Guide Chinese version of Getting Started Guide Spanish version of Getting Started Guide French version of Getting Started Guide Japanese version of Getting Started Guide Russian version of Getting Started Guide N9020BU-PCS 1CP105A 1CN103A 1CM113A 1CR013A N9020BU-PRC MLP001A N9020BU-AB1 N9020BU-AB2 N9020BU-ABE N9020BU-ABF N9020BU-ABJ N9020BU-AKT Requirements (MXA must already include the following) Front end controller with hardware ID 41 or 75 Front end controller without hardware ID 41 or 75 None PC6, W7X PC6 None None None None None None None None None None None None Additional information Press System, Show, Hardware to determine hardware ID Includes hardware and license key Provides a removable solid-state drive with Windows 10 operating system Upgrade to quad-core, high-performance processor, 16 GB RAM, with flash calibration file memory and removable solid-state drive Not compatible with Option PRC, 1CN103A, 1CM113A Not compatible with Option PRC, 1CP105A, 1CM113A Not compatible with Option PRC, 1CP105A, 1CM113A Not compatible with Option PRC Not compatible with Options 1CM, 1CP, 1CN, 1CR 1CP105A, 1CM113A, 1CN103A, 1CR013A Related Literature Keysight MXA signal analyzers Publication title X-Series Signal Analyzers - Brochure N9020B MXA X-Series Signal Analyzer, Multi-touch - Data Sheet X-Series Measurement Applications - Brochure Publication number 5992-1316EN 5992-1255EN 5989-8019EN Learn more at: www.keysight.com For more information on Keysight Technologies' products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Find us at www.keysight.com This information is subject to change without notice. © Keysight Technologies, 2015 - 2021, Published in USA , March 31, 2021, 5992-1254EN Page 11Adobe PDF Library 15.0