Ibis Networks 200 RF Module User Manual DataSheetSinglex

Ibis Networks Inc. RF Module DataSheetSinglex

Contents

User Manual - IS-201

IS-201 InteliSocket™   Ibis Networks · 828 Fort Street Mall Suite 600 · Honolulu, HI 96813 · www.ibisnetworks.com  1 05/28/15  FEATURES  • 120V 15A  • UL Certification • ZigBee Pro • 128 bit AES Security • 20dBm RF Power • Surge Protected • 0C to 40C   DESCRIPTION  The IS-201 is a smart socket which meters plug load energy usage and provides device on/off capability.    It  works  with  other  InteliSocketsTM  to  form  a  secure  wireless  mesh  network  for control  and  reporting  of  data.    Each  network  has  an  InteliGatewayTM  base  station  providing connectivity to the Ibis InteliNetworkTM, a cloud-based data collection and analysis application.  InteliSockets can be configured to operate on any of the 15 ZigBee channels.  In addition, the hive (PANID) has over 4000 possible settings, preventing nearby systems from interfering with each other.    PERFORMANCE  Parameter  Symbol  Min  Typ  Max  Units Input Voltage (RMS)  VIN 108  120  132  V Input Frequency      60    Hz Output Current (RMS)  IOUT     15  A Output Power  POUT     1800  W Power Consumption      1    W Reporting Interval    1  15  255  s Accuracy (Energy)        0.5  % Accuracy (Voltage)        2  % Accuracy (Interval)        1  ms Resolution      1    W-s RF Range      50    m RF Transmit Power    0    20  dBm Sockets per Network        120   ZigBee Channels    11    25   ZigBee Hive    0x3000    0x3FFF   Size    4.1 x 2.2 x 1.7  inches
IS-201 InteliSocket™   Ibis Networks · 828 Fort Street Mall Suite 600 · Honolulu, HI 96813 · www.ibisnetworks.com  2 05/28/15  COMPLIANCE  Agency  File UL916 – Energy Management Equipment  E470522 ZigBee Profile (Ibis Automation)  0x114B FCC  2AECN200  ENVIRONMENTAL  Parameter  Symbol  Min  Typ  Max  Units Operating Temperature  TO  0  25  40  C Storage Temperature  TS  -40    100  C Relative Humidity  RH  0    95  %  InteliSockets are for indoor use only.    PROTOCOL  InteliSockets  use  the  Ibis  custom  ZigBee  profile  for  commands,  acknowledgements,  and reporting of data.  Refer to the V2 Protocol documentation for details.    DATA  InteliSockets report data typically every 15 seconds.  Each report packet is comprised of socket type,  ZigBee  channel,  ZigBee  hive  (PANID),  interval  (seconds),  voltage  (RMS),  frequency  (Hz), energy  (watt-seconds),  and  power  factor  (fraction).    From  these  data  we  can  calculate instantaneous power (watts) and current (amps).          ·   The  InteliGateway  appends  additional  information  (IP,  timestamp,  location,  etc.)  before uploading  to  the  InteliNetwork.    This  allows  any  socket  in  the  world  to  be  located  and addressed individually.
IS-201 InteliSocket™   Ibis Networks · 828 Fort Street Mall Suite 600 · Honolulu, HI 96813 · www.ibisnetworks.com  3 05/28/15  PUSHBUTTON  The small pushbutton on the side provides addition control features.  First and foremost, it is a manual override for turning the outlet on and off (toggle).  If pressed for at least two seconds, it causes a reboot of the socket.  Finally, if the pushbutton is pressed while plugging in the socket, a factory reset is performed causing the socket to revert back to factory default settings.  This is a useful feature for maintenance purposes.    LED  The  LED  on  the  front  indicates  the  state  of  the  socket.    When  red  the  outlet  is  off;  green  is outlet is on.  If LED is blinking, the socket has not yet associated with a mesh network.  During a reboot, the LED will flash yellow for a second.    FCC  This equipment has been tested and found to comply with the limits for a class B digital device, pursuant  to  part  15  of  the  FCC  rules.    These  limits  are  designed  to  provide  reasonable protection against harmful interference in a residential installation.  This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause  harmful  interference  to  radio  or  television  reception,  which  can  be  determined  by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to  which  the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.  The  user  is  cautioned  that  changes  and  modifications  made  to  the  equipment  without  the approval of manufacturer could void the user’s authority to operate this equipment.   To  satisfy  RF  exposure  requirements,  this  device  and  its  antenna  must  operate  with  a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Navigation menu