3M Traffic Safety Systems 6204 3M UHF RFID Reader User Manual

3M Traffic Safety Systems 3M UHF RFID Reader

Contents

User manual

Download: 3M Traffic Safety Systems 6204 3M UHF RFID Reader User Manual
Mirror Download [FCC.gov]3M Traffic Safety Systems 6204 3M UHF RFID Reader User Manual
Document ID2464263
Application IDSzUIFN+MGbP7IKyEW/1Jyg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize181.55kB (2269421 bits)
Date Submitted2014-12-04 00:00:00
Date Available2014-12-04 00:00:00
Creation Date2014-10-28 17:53:21
Producing SoftwarePDF Architect
Document Lastmod2014-11-13 17:22:30
Document TitleUser manual
Document CreatorPDF Architect
Document Author: A4AWKZZ

3M Toll RFID Reader 6204
User’s Guide
V1.4.5
October 28, 2014
© 3M 2014. All Rights Reserved.
3M is a trademark of 3M. All other trademarks are the property of their respective owners. Specifications are subject to change without
notice.
Disclaimer and Limitation of Liability
The content of this manual is for information use only and is subject to change without notice. 3M assumes no responsibility or liability for
any errors or inaccuracies that may appear in this publication. No part of this manual may be reproduced in any form or by any means,
electronic, mechanical, recording, or otherwise, without the prior written permission of 3M.
3M products are not designed, intended, authorized or warranted to be suitable for life support applications or any other life critical
applications which could involve potential risk of death, personal injury, property damage, or environmental damage.
FCC Notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Canadian Note: CAN ICES-3(A)/NMB-3(A)
FCC Notice (Wiegand Interface Module)
The Wiegand Interface Module has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules.
FCC Radiation Exposure Statement
The antennas used for this transmitter must be installed to provide a separation distance of at least 1.2 meters from all persons and must
not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Health Canada’s Safety Code.
The installer of this device should ensure that RF radiation is not emitted in excess of the Health Canada’s requirement. Information can be
obtained at
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct/index-eng.php
Cet appareil est conforme avec Santé Canada Code de sécurité 6. Le programme d’installation de cet appareil doit s’assurer que les
rayonnements RF n’est pas émis au-delà de I’exigence de Santé Canada. Les informations peuvent être obtenues:
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct/index-fra.php
NOTICE
The 3M Toll RFID Reader 6204 is designed to meet the regulatory requirements in those jurisdictions in which it is offered. Changes or
modifications not expressly approved by 3M for compliance could void the user's authority to operate the equipment.
Patent: 3M.com/patent
Product ID: RFID6204
3M Traffic Safety and Security Division
Motor Vehicle Safety Systems
Building 3
11705 Research Blvd
Austin, TX 78759
Web: www.3m.com
Preface
Preface
Intended audience
This document is intended for those who wish to setup and operate the 3M
Toll RFID Reader 6204. Before attempting to install, configure, and operate
this product, you should be familiar with the following:
 Windows-based software installation and operation
 Device communication parameters including Ethernet and serial
communications
 RFID reader configuration including antenna placement
 Basic digital input/output control
What’s in this guide
The information in this guide is presented as follows:
Chapter 1 - Reader
Reader Overview:
Overview This chapter provides a brief overview of the 3M Toll
RFID Reader 6204 hardware and software.
Chapter 2 – Safety Information – This chapter provides important safety
information about the 3M Toll RFID Reader 6204. All users must read this section
before installing or operating this reader.
Chapter 3 - Reader Equipment Installation – This chapter describes how to
mechanically and electrically install the reader.
Chapter 4 - Reader Startup Tool (RST) Software Installation – This chapter
describes how to install the Microsoft Windows RST application.
Chapter 5 - Reader Operation – This chapter describes how to initially test a reader
and how to operate deployed readers.
Chapter 6 - Reader Startup Tool (RST) – This chapter describes the RST and the
various functions you can perform with this Microsoft Windows application.
Chapter 7 - Reader Configuration Tool (RCT) – This chapter describes the RCT and
the various functions you can perform with this embedded reader application.
Chapter 8 - Configuring Digital Inputs and Outputs – This chapter describes how to
setup the reader’s digital inputs and outputs.
Chapter 9 - Specifications – This chapter detailed mechanical, electrical, and
environmental specifications for the 3M Toll RFID Reader 6204.
Appendix A – Using the Wiegand Interface – This appendix provides instruction for
installing and configuring the Wiegand Interface Module.
Appendix B – Error Handling – This appendix lists 3M Toll RFID Reader 6204 errors
and warnings. Corrective actions are provided where applicable.
Appendix C – Reader Maintenance – This appendix provides instruction for
performing any reader maintenance activities.
3M Toll RFID Reader 6204 User’s Guide
Preface
What’s New in this Version
Version 1.4 updates the Reader Setup Wizard, Reader Startup Tool, Reader
Test Tool, Reader Diagnostic Tool, and the Reader Configuration Tool.
Additional product use and safety information has been added.
Conventions used in this manual
The following conventions are used in this manual:
Bold courier font indicates code entered by the user
(values) within parentheses indicate parameters
NOTES
Important information
and other tips are
presented in light
blue boxes to the left
of the applicable
section.
(values) in italics indicate user defined variables.
 indicates a variable number used in a function that can apply to
several different devices such as antennas or I/O ports.
WARNING: Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor
or moderate injury or property damage.
ATTENTION:
NOTICE
ii
This yellow symbol indicates that the device is susceptible to
Electro Static Discharge and appropriate precautions must be
taken to avoid equipment damage.
NOTICE advises the reader that a condition can be created by a particular action that
can cause equipment damage or result in equipment operation that violates regulatory
requirements.
3M Toll RFID Reader 6204 User’s Guide
Preface
Product Use Statement
Product Use: Many factors beyond 3M’s control and uniquely within user’s
knowledge and control can affect the use and performance of a 3M product
in a particular application Given the variety of factors that can affect the
use and performance of a 3M product, user is solely responsible for
evaluating the 3M product and determining whether it is fit for a particular
purpose and suitable for user’s method of application.
Warranty, Limited Remedy, and Disclaimer: Unless a different warranty is
specifically stated on the applicable 3M product packaging, product
literature, terms of sale or software license agreement, 3M warrants that (i)
the 3M product will be free from substantial defects in material and
workmanship under normal use and service for one (1) year from the
original date of purchase, and (ii) for software products, for ninety (90) days
from the original date of purchase, the software will materially perform the
functions described in the accompanying documentation. 3M MAKES NO
OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING,
BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY
IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF
DEALING, CUSTOM OR USAGE OF TRADE. If the 3M product does not
conform to this warranty, then the sole and exclusive remedy is, at 3M’s
option, repair or replacement of the 3M product.
Limitation of Liability: Except where prohibited by law, 3M will not be liable
for any loss or damage arising from the 3M product, whether direct,
indirect, special, incidental or consequential, regardless of the legal theory
asserted, including warranty, contract, negligence or strict liability.
3M Toll RFID Reader 6204 User’s Guide
iii
Preface
iv
3M Toll RFID Reader 6204 User’s Guide
Contents
Table of Contents
Reader Overview ................................................................................................................................... 1
1.1. Reader Hardware ................................................................................................................................. 1
1.2. Reader Software ................................................................................................................................... 2
Safety Information ............................................................................................................................... 3
2.1. Intended Use ......................................................................................................................................... 3
2.2. Explanation of Signal Word Consequences...................................................................................... 3
2.3. Attendant Warnings ............................................................................................................................. 3
2.4. Installation and Service Technician Warnings and Cautions ........................................................ 4
2.4.1. Power Supply Related ...............................................................................................................4
2.4.2. Reader System Related ..............................................................................................................5
2.5. RF Safety................................................................................................................................................ 7
2.6. Electrostatic Discharge ........................................................................................................................ 7
2.7. Regulatory Compliance ....................................................................................................................... 8
2.7.1. FCC Notice (3M Toll RFID Reader 6204) ...............................................................................8
2.7.2. FCC Notice (Wiegand Interface Module) .................................................................................8
2.8. Power/Data Cable Size ....................................................................................................................... 8
Reader Equipment Installation .......................................................................................................... 9
3.1. Mechanical Installation ....................................................................................................................... 9
3.2. Electrical Installation ........................................................................................................................ 11
3.2.1. Connecting the Serial Port.......................................................................................................12
3.2.2. Connecting and Configuring the Ethernet Port .......................................................................12
3.2.3. Connecting Digital Inputs/Outputs..........................................................................................12
3.2.4. Connecting the Power .............................................................................................................13
3.2.5. Installation with the 3M Reader Redundancy Switch .............................................................13
Reader Startup Tool (RST) Software Installation ......................................................................... 14
4.1. Installing RST Software .................................................................................................................... 14
4.2. Windows 7 Setup............................................................................................................................... 16
4.3. Reader Startup................................................................................................................................... 17
4.4. Initial Reader Setup .......................................................................................................................... 18
3M Toll RFID Reader 6204 User’s Guide
Contents
Reader Operation .............................................................................................................................. 22
5.1. Basic Operation with RST ................................................................................................................. 22
5.2. Deployed Reader Operation with RCT ............................................................................................ 24
Reader Startup Tool (RST) ............................................................................................................... 26
6.1. View Readers on the Network ......................................................................................................... 26
6.2. Configure Reader with the Setup Wizard ...................................................................................... 27
6.3. Customize Discovery Options .......................................................................................................... 28
6.4. View or Change the Reader’s Network Settings ........................................................................... 29
6.5. Reader Test Tool (RTT)...................................................................................................................... 30
6.5.1. General Page ........................................................................................................................... 30
6.5.2. Tag Performance Page ............................................................................................................ 34
6.5.3. Tag Management Page ............................................................................................................ 36
6.5.4. Macros Page ............................................................................................................................ 37
6.5.5. Event Handling Page ............................................................................................................... 39
6.5.6. Antenna Settings Page............................................................................................................. 40
6.6. Reader Diagnostics Tool (RDT) ........................................................................................................ 41
6.6.1. Channel Statistics .................................................................................................................... 41
6.6.2. Alarms ..................................................................................................................................... 42
6.6.3. Tag Report ............................................................................................................................... 43
6.6.4. Spectrum Analyzer .................................................................................................................. 44
6.6.5. Power Ramp Tool ................................................................................................................... 45
Embedded Reader Configuration Tool (RCT) ................................................................................ 46
7.1. Basic Configuration ........................................................................................................................... 47
7.1.1. Configuration Page Header ..................................................................................................... 47
7.1.2. Manage Profiles ...................................................................................................................... 48
7.1.3. Set Tag Protocol ...................................................................................................................... 50
7.1.4. Setup Ethernet/LAN ................................................................................................................ 51
7.1.5. Setup Serial Port...................................................................................................................... 52
7.1.6. Setup Digital Accessories ....................................................................................................... 53
7.1.7. Setup Antenna/Cables ............................................................................................................. 54
7.1.8. Set Regulatory Mode (Region) ............................................................................................... 55
7.1.9. Setup Summary ....................................................................................................................... 55
7.2. Advanced Functions .......................................................................................................................... 56
7.2.1. Firmware Management ........................................................................................................... 57
7.2.2. Import/Export Configuration .................................................................................................. 58
7.2.3. Command Line ........................................................................................................................ 61
vi
3M Toll RFID Reader 6204 User’s Guide
Contents
7.3. Expert Configuration ......................................................................................................................... 62
7.3.1. Expert Configuration – Setup ..................................................................................................62
7.3.2. Expert Configuration – Tag.....................................................................................................63
7.3.3. Expert Configuration – Version ..............................................................................................64
7.3.4. Expert Configuration – Information ........................................................................................65
7.3.5. Expert Configuration – Communication .................................................................................66
7.3.6. Expert Configuration – Antennas ............................................................................................67
7.3.7. Expert Configuration – Digital I/O .........................................................................................68
7.3.8. Expert Configuration – Security .............................................................................................69
7.3.9. Expert Configuration – Writeback ..........................................................................................70
7.3.10. Expert Configuration – Modem ..............................................................................................71
7.4. User Application Management ........................................................................................................ 74
7.5. Change Operating Mode................................................................................................................... 75
7.6. Wiegand Translation Table .............................................................................................................. 76
7.7. View Tags ............................................................................................................................................ 77
7.8. Check Reader Status ........................................................................................................................ 78
7.9. Review Logs ....................................................................................................................................... 80
Configuring Digital Inputs and Outputs .......................................................................................... 81
8.1. Digital Inputs ...................................................................................................................................... 81
8.2. Digital Outputs ................................................................................................................................... 81
8.3. Low Latency Digital Input/Output Operation ................................................................................ 81
8.4. Digital I/O Monitoring and Control Scripts .................................................................................... 83
8.4.1. scan_trigger.py ........................................................................................................................83
8.4.2. scan_trigger_timer.py ..............................................................................................................84
8.4.3. signal_read.py .........................................................................................................................84
8.4.4. signal_read_crc_error.py .........................................................................................................85
8.4.5. rf_mon.py ................................................................................................................................85
8.5. Digital Input Alarm Generation ....................................................................................................... 86
8.6. Digital I/O Hardware Connection .................................................................................................... 87
Specifications ..................................................................................................................................... 88
9.1.1. Reader Specifications (General)..............................................................................................88
9.1.2. Environmental Specifications .................................................................................................89
9.1.3. AC/DC Power Adapter Specifications ....................................................................................89
9.1.4. RS-232 Specifications .............................................................................................................90
9.1.5. Digital Input/Output Specifications ........................................................................................90
9.1.6. Ethernet LAN Specifications ..................................................................................................90
9.1.7. 3M Toll RFID Reader 6204 Antenna Specifications ..............................................................91
9.1.8. Bulkhead Connector/Interface Cable Pinout ...........................................................................94
3M Toll RFID Reader 6204 User’s Guide
vii
Contents
Using the Wiegand Interface ........................................................................................................... 96
A.1.
Overview ................................................................................................................................. 96
A.2.
Wiegand Protocol .................................................................................................................... 96
A.3.
Wiegand Applications ............................................................................................................. 97
A.4.
Mechanical Installation ........................................................................................................... 98
A.5.
Electrical Installation .............................................................................................................. 99
A.6.
Disconnecting the Wiegand Interface Module ...................................................................... 102
A.7.
Using RCT to Configure the Wiegand Interface Module ..................................................... 103
A.8.
Converting Translation Tables for use with 6204 ................................................................. 106
A.9.
Importing/Exporting a Translation Table ............................................................................. 107
A.10. Programming the Wiegand Interface .................................................................................... 108
A.11. Programming the Translation Table...................................................................................... 117
A.12. Interaction between Translation Table and Wiegand-Encoded Tags ................................... 119
A.13. Transaction Log .................................................................................................................... 120
A.14. Module Specifications ........................................................................................................... 121
Error Handling .................................................................................................................................. 122
B.1.
Critical Errors ........................................................................................................................ 122
B.2.
Major Errors .......................................................................................................................... 123
B.3.
Warnings ............................................................................................................................... 127
B.4.
Informational Messages ........................................................................................................ 129
Reader Maintenance ...................................................................................................................... 131
C.1.
Visually Inspect all Readers and Antennas (6 months) ........................................................ 131
C.2.
Inspect Reader Support Hardware (6 months) ...................................................................... 131
C.3.
Inspect Power and Communication Connections (6 months) .............................................. 131
C.4.
Inspect and Clean Antenna Radome (6 months) ................................................................... 131
C.5.
Check Reader Error Log (3 months) ..................................................................................... 131
C.6.
Verify Antenna Mapping (as required) ................................................................................. 131
viii
3M Toll RFID Reader 6204 User’s Guide
Contents
This page intentionally left blank.
3M Toll RFID Reader 6204 User’s Guide
ix
1
2 3 4 5 6 7
8 9
Reader Overview
1.1.
Reader Overview
Reader Hardware
The 3M Toll RFID Reader 6204 is a multi-protocol, multi-regional Radio
Frequency Identification (RFID) System that operates in the 860–960 MHz
UHF band. The reader is configured at the factory to operate within a
specific regulatory region (for example: FCC Part 90).
Figure 1
3M Toll RFID Reader 6204
As shown in the following figure, the 6204 supports four Tx/Rx antennas
(not shown). The reader is also equipped with RS-232 serial and Ethernet
interfaces.
Figure 2
3M Toll RFID Reader 6204 User’s Guide
3M Toll RFID Reader 6204 Power and I/O Connections
1
1.2.
3 4 5 6
7 8 9
Reader Overview
Reader Software
The 6204 is shipped with two software applications that you can use to
configure and control the reader.
Reader Startup Tool (RST)
(RST)
The RST is a Microsoft Windows based application you install on your
computer. With RST, you can view all readers on your network. After
selecting a reader, you can modify its communication, network, and
operational parameters. You can also read tags, review tag data, and
perform diagnostics. This RST is primarily intended for initially configuring a
reader prior to deployment. After deployment, use the Embedded Reader
Configuration Tool (RCT). Detailed information on the RST is provided in
Chapter 5.
Embedded Reader Configuration Tool (RCT)
This RCT is an embedded reader application that allows you to access your
readers across a LAN or WAN. Enter the IP address of the reader into your
Web browser and the RCT allows you to fully modify and operate the reader.
With the same functionality as the RST, this application allows you to modify
the reader’s communication, network, and operational parameters. You can
also read tags, review tag data, perform diagnostics, and upload new
software. This application is primarily intended for configuring and
managing deployed readers. Detailed information on the RCT is provided in
Chapter 6.
3M Toll RFID Reader 6204 User’s Guide
1
3 4 5
6 7 8 9
Reader Equipment Installation
Safety Information
Please read, understand, and follow all safety information contained in
these instructions prior to the use of this RFID Interrogator/Reader product.
Retain these instructions for future reference.
2.1.
Intended Use
This RFID Interrogator/Reader product is intended for use with RFID
antennas and transponders in vehicle related applications such as
Automatic Vehicle Identification (AVI), Intelligent Transportation Systems
(ITS), Traffic Management Systems (TMS), Electronic Vehicle Registration
(EVR) and/or parking and access control. It is expected that all users be
fully trained in the safe operation of this device. Use in any other application
has not been evaluated by 3M and may lead to an unsafe condition.
2.2.
Explanation of Signal Word Consequences
WARNING:
Indicates a hazardous situation which, if not avoided, could result in
WARNING
death or serious injury
CAUTION:
Indicates a hazardous situation which, if not avoided, could result in
CAUTION
minor or moderate injury or property damage.
NOTICE:
2.3.
Indicates a situation which, if not avoided, could result in property
damage.
Attendant Warnings
WARNING:
To reduce the risks associated with hazardous voltage, and nonWARNING
ionizing radiation exposure:
• Do not modify or attempt to service the Reader System. Return to 3M authorized
service centers for repair or service. There are no user serviceable parts.
WARNING:
WARNING
exposure:
To reduce the risks associated with exposure to non-ionizing radiation
• Do not modify software outside the parameters stated in the manual.
3M Toll RFID Reader 6204 User’s Guide
1
3 4 5
2.4.
6 7 8 9
Reader Equipment Installation
Installation and Service Technician Warnings and
Cautions
WARNING:
WARNING
To reduce the risks associated with hazardous voltage, fire and impact:
• Installation and service of 3M Toll RFID Reader systems is to be performed by
qualified installation personnel.
• Installation and service activities must be in compliance with all applicable
building and electrical codes.
• Inspect all system components at least every 6 months.
2.4.1.
Power Supply Related
WARNING:
WARNING
To reduce the risks associated with hazardous voltage and fire:
• Always disconnect the power supply system power before any installation,
maintenance, service or modification work.
• Ensure that it cannot be re-connected inadvertently.
• Connection to main power supply in compliance with VDE01000 and EN50178.
• With Stranded wires: all strands must be secured in the terminal blocks.
• Power supply and cables must be properly fused.
• If necessary, a manually controlled disconnecting element must be used to
disengage from supply mains.
• All output lines must be rated for the power supply output current and must be
connected with the correct polarity.
• Do not block vents on power supply.
• For use in only a Pollution Degree 2 environment.
• Do not introduce any object into the power supply.
• Keep power supply away from fire and water.
3M Toll RFID Reader 6204 User’s Guide
1
3 4 5
2.4.2.
6 7 8 9
Reader Equipment Installation
Reader System Related
WARNING:
To reduce the risks associated with hazardous voltage and fire:
• Always disconnect AC power from the power supply unit when connecting or
disconnecting components of the system.
• System modification and service by 3M authorized personnel only.
WARNING: To reduce the risks associated with hazardous voltage, and nonionizing radiation exposure:
• Do not modify or attempt to service the Reader System. Return to 3M authorized
service centers for repair or service. There are no user serviceable parts.
WARNING:
To reduce the risks associated with non-ionizing radiation exposure
WARNING
and property damage:
• Always turn off the RF from the antenna before cleaning, inspecting, service or
repair.
WARNING:
WARNING
To reduce the risks associated with electromagnetic interference:
• Use only the antennas described in this manual or the 3M RFID Antennas for Toll
RFID Readers Application Guide.
3M Toll RFID Reader 6204 User’s Guide
1
3 4 5
6 7 8 9
Reader Equipment Installation
WARNING:
To reduce the risks associated with hazardous temperature and fire
WARNING
related to the power supply:
• Do not cover ventilation holes in power supply.
• Leave sufficient space around the power supply for cooling.
• Do not mount directly above a heat source.
• Disconnect unit from power before installation, maintenance, service, or
modification.
• Do not use in wet or damp locations.
• Do not use near flames.
• -Always disconnect AC power from the power supply unit when connecting or
disconnecting components of the system.
WARNING:
WARNING
To reduce the risks associated with hazardous voltage:
• Replace damaged components with only the 3M designated replacement parts.
• Use only the power supply specified by 3M
WARNING:
WARNING
To reduce the risks associated with fire and explosion:
• Do not install in a hazardous location.
WARNING:
WARNING
To reduce the risks associated with impact:
• Any mounting surface must be able to support a minimum static load of equal to
the maximum weight of the reader plus any additional live load due to
environmental conditions.
WARNING:
WARNING
abrasions:
To reduce the risks associated with impact, muscle strain and
• Use appropriate PPE and follow safe workplace practices during installation.
CAUTION:
To reduce the risks associated with hot surfaces and reader
CAUTION
performance:
• Do not paint the reader, antenna(s), and power supply any color.
CAUTION:
CAUTION
To reduce the risk associated with rough edges:
• Wear appropriate gloves when handling the reader and antenna mounting
hardware.
CAUTION:
CAUTION
To reduce the risks associated with environmental contamination:
• Dispose of all system components in accordance with applicable local and
government regulations, including removal of button battery, prior to disposal.
3M Toll RFID Reader 6204 User’s Guide
1
3 4 5
NOTICE:
2.5.
Reader Equipment Installation
Do not use 6204 with wire harness from previous reader installations. Power
pins have been moved.
Do not use solvents or harsh cleaners on radome or antennas.
RF Safety
NOTICE:
2.6.
6 7 8 9
The 3M Toll RFID Reader 6204 UHF Reader is equipped with four (4) RF ports.
To prevent reader damage, unused RF ports must be properly terminated with
a 50 ohm load or a functional UHF antenna before power up if the reader has
been configured to use this port. Never power up the reader unless the
appropriate loads or antennas are connected. Always power down the reader
before removing an antenna or load from an RF port.
The maximum antenna cable length is 10 meters.
Electrostatic Discharge
ATTENTION
3M Toll RFID Reader 6204 User’s Guide
3M Toll RFID Reader 6204 antenna ports may be susceptible to
damage from static discharge or other high voltage. Use proper
Electrostatic Discharge (ESD) precautions to avoid static discharge
when handling or making connections to the 3M Toll RFID Reader
6204 reader antenna or communication ports. Equipment failure
can result if the antenna or communication ports are subjected to
ESD.
1
3 4 5
2.7.
6 7 8 9
Reader Equipment Installation
Regulatory Compliance
NOTICE:
2.7.1.
The 3M Toll RFID Reader 6204 is designed to meet the regulatory requirements in
those jurisdictions in which it is offered. Changes or modifications not expressly
approved by 3M for compliance could void the user's authority to operate the
equipment.
FCC Notice (3M Toll RFID Reader 6204)
6204)
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.
2.7.2.
FCC Notice (Wiegand Interface Module)
The Wiegand Interface Module has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
2.8.
Power/Data
Power/Data Cable Size
NOTICE:
The 3M supplied power/data cable is only to be used with the 3M 24 VDC power
supply. Use of these cables with power supplies providing lesser voltages may result in
cable and/or reader damage.
3M Toll RFID Reader 6204 User’s Guide
1 2
4 5 6 7 8 9
Reader Equipment Installation
3.1.
Reader Equipment Installation
Mechanical Installation
The 3M Toll RFID Reader 6204 is available with two mounting flanges
suitable for most pole and wall mount applications. Any mounting surface
must be able to support a minimum static load of 11.0 pounds (5 kg) plus
any additional live load due to environmental conditions.
Figure 3
3M Toll RFID Reader 6204 Mechanical Dimensions and Mounting Hole Locations (Dimensions in Inches)
3M Toll RFID Reader 6204 User’s Guide
1 2
4 5 6 7 8 9
Reader Equipment Installation
To mount the 6204 assembly, refer to Figure 3 and perform the following:
10
Prepare the mounting surface to accept the 10 mounting bolts. The
hole pattern should match that shown in Figure 3 and the mounting
surface must be able to support 11 lbs (5 kg).
Mount the reader.
Locate the Interface Cable.
Connect the cable to the reader’s bulk head connector and twist to lock
in place.
Connect the antenna cables (see Figure 4).
Adjust the angle of the antennas and tighten the hardware.
3M Toll RFID Reader 6204 User’s Guide
1 2
3.2.
4 5 6 7 8 9
Reader Equipment Installation
Electrical Installation
A general installation diagram is shown in the following figure. Refer to
Chapter 7 – Specifications for specific information.
Installation
Notice
Installation of the
3M Toll RFID
Reader 6204 is
only to be
performed by
trained, 3M
approved
personnel.
Figure 4
NOTICE:
NOTICE:
3M Toll RFID Reader 6204 Electrical Connections
The 3M Toll RFID Reader 6204 is designed to meet the regulatory requirements in those
jurisdictions in which it is offered. Changes or modifications not expressly approved by 3M
for compliance could void the user's authority to operate the equipment.
ATTENTION 3M Toll RFID Reader 6204 antenna ports may be susceptible to damage
from static discharge or other high voltage. Use proper Electrostatic
Discharge (ESD) precautions to avoid static discharge when handling or
making connections to the 3M Toll RFID Reader 6204 reader antenna or
communication ports. Equipment failure can result if the antenna or
communication ports are subjected to ESD.
3M Toll RFID Reader 6204 User’s Guide
11
1 2
3.2.1.
4 5 6 7 8 9
Reader Equipment Installation
Connecting the Serial Port
The 6204 RS-232 serial port provides communication up to 115200 Baud.
This port is accessed through the bulkhead connector on the reader. If you
are using the serial port for reader communication, connect a serial cable
from the COM port on your PC to the serial port on the reader. See Figure 2
for location of the connector.
Refer to the Chapter 8 – Specifications for details on the bulkhead
connector.
3.2.2.
Connecting and Configuring the Ethernet Port
The 6204 Ethernet port is accessed through the bulkhead connector. If you
are communicating with your reader across a Local Area Network (LAN),
connect an Ethernet cable from your hub or router to the bulkhead
connector.
By default, the reader is configured to use a DHCP server to obtain its IP
address and related information. In the event a DHCP server is unavailable,
the reader will boot with an IP address in the 169.254.x.x subnet.
In the absence of other readers on the same network, and if no other
network traffic is observed which references 169.254.1.1, the reader will
select that address; otherwise, it will select a random address on the
169.254.x.x subnet.
IP address settings can be changed using RST. Refer to the View or Change
the Reader’s Network Settings section in Chapter 5.
Refer to the Chapter 8 – Specifications for details on the bulkhead
connector.
3.2.3.
Connecting Digital Inputs/Outputs
The 6204 is equipped with a general purpose digital input/output (I/O) port
that provides four optically isolated 5-24 VDC input signals and four opencollector output signals. The digital inputs can be used as general purpose
inputs or to trigger the reader for tag reading. These inputs can be
configured to provide an external read trigger from proximity sensors, photo
switches, or other devices.
The digital outputs can be used as general purpose outputs, to indicate tag
reading activity, or to indicate the reader is transmitting (RF On). The
outputs can also be configured to trigger conveyor gates or other access
control and sorting devices. For detailed information on configuring the
digital inputs and outputs refer to Chapter 7.
12
3M Toll RFID Reader 6204 User’s Guide
1 2
3.2.4.
4 5 6 7 8 9
Reader Equipment Installation
Connecting the Power
The 6204 operates on 24 Vdc ±5% provided through the bulkhead
connector on the rear of the reader.
The bulkhead power connections are as follows. Note that both pairs must
be connected.
Pair
Pin
Color
Red
Green
Yellow
Green
16
Pin Name
+24 VDC
24 VDC GND
+24 VDC
24 VDC GND
Function
Power
Ground
Heater Power
Heater Ground
Connect the power supply to the reader cable as shown and connect the
power supply to your 100–240 Vac, 50-60 Hz power source. Allow 30
seconds for the reader to initialize.
NOTICE:
NOTICE:
If DC power is disconnected from the reader, wait a minimum of 30 seconds before
reapplying power.
Refer to the Chapter 8 – Specifications for additional details on the
bulkhead connector.
NOTICE:
NOTICE:
3.2.5.
The 3M supplied power cable is only rated at 24V ±5%. Input power less than 24V ±5% while
using 3M supplied cables may result in cable and/or reader damage.
Installation with the 3M Reader Redundancy Switch
The 6204 can be installed with the optional 3M Reader Redundancy Switch
(RRS). The RRS interfaces two 3M Toll RFID Reade 6204s and their
associated antenna systems to provide an antenna change over facility in
the event of a reader failure. Please consult the 3M Reader Redundancy
Switch User’s Guide for installation details.
3M Toll RFID Reader 6204 User’s Guide
13
1 2
RST Software Installation
Reader Startup Tool (RST) Software Installation
4.1.
Installing RST
RST Software
The 3M Toll RFID Reader 6204 is delivered with a Microsoft Windows
application called Reader Startup Tool (RST). You can use this application to
initially configure your reader as well as read and display tag data.
NOTE: The product CD provided with your reader contains a setup file called setup.exe.
This file will fully check your system configuration and load all required software
including Microsoft .Net 4.5.
Install RST
1 To install RST, load your product CD and double-click the setup.msi file:
2 Press Next>
14
Read the License Agreement. Select
I accept the terms… and press Next>
3M Toll RFID Reader 6204 User’s Guide
1 2
Select Setup Type. Press Next>.
5 Monitor the progress of the installation.
3M Toll RFID Reader 6204 User’s Guide
RST Software Installation
5 Press Install.
After the installation completes, press Finish.
15
1 2
4.2.
RST Software Installation
Windows 7 Setup
If you have a Windows 7 operating system, your firewall may block UDP
traffic and consequently RST may not discover your readers. Perform the
following to configure your system:
For Microsoft Firewall
1 Log into your computer as Administrator.
2 Navigate to the Control Panel and select
Control Panel → System and Security.
3 Select Allow a program through Windows firewall.
4 Scroll down the list and locate Startup Tool, check it, and press OK.
5 If Startup Tool is not in the list, press Allow another program.
6 Locate Startup Tool, check it, and press OK.
7 Restart RST and it should discover readers.
For ThirdThird-Party Firewalls
1 Log into your computer as Administrator.
2 Set your firewall to allow RST to receive UDP traffic on port 50000 and
50001.
16
3M Toll RFID Reader 6204 User’s Guide
1 2
4.3.
RST Software Installation
Reader Startup
To begin using your reader, open the RST application.
Open RST
1 From your Windows desktop, select:
Start→Programs→3M→Reader Startup Tool (RST)
NOTE:
Earlier versions of
Microsoft Windows™
may not provide the
Security Alert popup.
IF RST does not
discover your reader,
check your Windows
Firewall/Security
settings.
If this is the first time starting the RST application, you may receive a
Windows Security Alert. This warning indicates that the firewall is
blocking the RST application.
If the warning window is hidden under the RST windows, collapse the
RST window.
Press Unblock.
Press Refresh on the RST
The RST main page will display any readers currently connected to the
network.
3M Toll RFID Reader 6204 User’s Guide
17
1 2
4.4.
RST Software Installation
Initial Reader Setup
To configure a specific reader, perform the following:
Reader Setup
1 Select the reader on the main RST page by clicking the button to the left
of the reader Mac address.
2 Press the
button on the RST tool bar or select Setup
Wizard from the Tools pull-down menu.
3 The Reader Setup Wizard (RSW) is displayed.
18
3M Toll RFID Reader 6204 User’s Guide
1 2
Login Page
The reader Login
Page is only
displayed when the
default login is set to
guest. Readers
leave the factory with
a default login of
admin. Therefore,
you will not see the
login screen if you
have not configured
your reader.
Region Selection
The reader is
configured at the
factory to operate
within a specific
regulatory region. As
a result your region
selections may be
different from those
shown in this
manual.
Note that Region
Selection is not user
configurable.
RST Software Installation
Press Next> and enter the Login (admin) and Password. If this is the
first time configuring your reader, enter: readeradmin.
After entering your Login and Password, press Next>
Select the Region and Sub Region and press Next>.
Protocols
Only those protocols
enabled in the reader
will be active on the
Protocol Selection
page.
3M Toll RFID Reader 6204 User’s Guide
19
1 2
RST Software Installation
Select the protocol of the tags you will be reading and press Next>.
Select the antennas you will be installing and press Next>.
Estimate the number of tags that will be presented to the reader at any
one time and press Next>.
Custom Setup
If your installation
type differs from one
of the choices shown
in the Setup Wizard,
you can always
customize your setup
later using the
embedded web
interface capability.
See the Advanced
Setup chapter in this
guide for more
information.
20
3M Toll RFID Reader 6204 User’s Guide
1 2
RST Software Installation
Saving Reader Setup
Reader setup
information should be
saved as a profile. In
the event that you
need to reboot or
power down a reader,
the reader setup can
be quickly reloaded
by loading the profile.
If you don’t save the
reader setup, you can
lose the information if
the reader is
rebooted.
10 It is highly recommended that you save the reader setup as a profile.
Select Save changes to a profile…, enter a Profile Name, and press
Finish to complete the initial reader setup.
3M Toll RFID Reader 6204 User’s Guide
21
1 2
Reader Operation
Reader Operation
5.1.
Basic Operation with RST
The 3M Toll RFID Reader 6204 can be operated either from the RST
application or by logging directly into the reader’s embedded Reader
Configuration Tool (RCT). To operate the reader from RST, perform the
following:
Open RST
From your Windows desktop, select:
Start→Programs→3M→Reader Startup Tool (RST)
Customize the display
Customize your RST
display by clicking
and dragging the
columns. You can
also sort by column.
22
Select a reader and press
from the Tools pull-down menu.
on the RST tool bar or select Test
3M Toll RFID Reader 6204 User’s Guide
1 2
Reader Operation
The Reader Test Tool (RTT) is displayed.
Login to the reader. From the pull-down menu select Reader→Login….
For administrator login, select admin. The initial password (Pwd) is
readeradmin. Refer to the 3M Toll RFID Reader 6204 Protocol
Protocol
Reference Guide for instructions on how to use the reader.set_pwd
command to change the password.
Verify the Operating Mode is set to Active. From the pull-down menu
select Operating Mode→Active.
Select the Tag Performance tab and press Start.
Place tags in front of antenna and verify tags are read and displayed.
3M Toll RFID Reader 6204 User’s Guide
23
1 2
5.2.
Reader Operation
Deployed Reader Operation with RCT
Once your readers are deployed, you can access them directly using the
embedded Reader Configuration Tool (RCT). To access a particular reader,
perform the following:
24
Enter the reader’s IP address into your web browser, press the
button on the RST tool bar or select Configure from the
Tools pull-down menu.
The reader’s RCT interface is displayed.
Log into the reader. Press Login for the login screen.
The default login is guest. If you need administrator privileges, login as
admin and enter readeradmin as the password.
Press Submit.
Select Basic Configuration →Setup Antenna/Cables to configure the
antennas, gain, and power settings.
3M Toll RFID Reader 6204 User’s Guide
1 2
Reader Operation
Select Advanced Functions →Change Operating Mode to verify the
reader is in the proper mode.
Select Basic Configuration →Set Tag Protocol to verify the reader is
configured for the proper tag protocol.
Press System Status →View Tags to view tag data.
10 If you need to configure additional changes to your reader, refer to
Chapter 7 – Reader Configuration Tool for information on using RCT to
adjust configuration variables and parameters.
3M Toll RFID Reader 6204 User’s Guide
25
1 2
Reader Startup Tool
Reader Startup Tool (RST)
The Reader Startup Tool (RST) provides an easy-to-use interface for the 3M
Toll RFID Reader 6204 configuration and operation functions. This
application resides on your Windows based computer and allows you to
perform the following:
6.1.
View all readers on the network
Launch the Reader Setup Wizard to configure a reader
View and change a reader’s network settings
Add a new reader to the network
Launch Reader Test Tool to perform basic reader/tag operations
Launch Reader Diagnostic Tool to view statistics, alarms, and reports
View Readers on the Network
When RST starts up, all readers currently connected to the network and
powered up are displayed.
26
3M Toll RFID Reader 6204 User’s Guide
1 2
6.2.
Reader Startup Tool
Configure Reader with the Setup Wizard
The Reader Setup Wizard is used to initially configure your reader for
operation. With this application, you can select the following:
Installation type
Regulatory region and sub-region
Protocol
Number of antennas
Estimated tag volume
To initially configure your reader perform the following:
Press the
button on the RST tool bar or select Setup
Wizard from the Tools pull-down menu.
2 The Reader Setup Wizard (RSW) is displayed.
Refer to Chapter 2 – Reader Configuration for detailed instructions on
using the Reader Setup Wizard.
3M Toll RFID Reader 6204 User’s Guide
27
1 2
6.3.
Reader Startup Tool
Customize Discovery Options
You can customize the reader discovery options including the Listen
Address and Request Multicast Address.
 Listen Address – Address that RST uses to listen for UDP discovery
packets from the reader. This is customizable on the reader.
 Request Multicast Address –Address used by RST to send out the UDP
update request packets. This is customizable on the reader.
In addition, you can select if you want a secure connection for the Test,
Configure, and Diagnostic Tools. This connection uses the HTTPS protocol
and any data transferred between devices is encrypted.
On the RST tool bar select Options from the Discovery pull-down menu.
Select either IP version 4 or IP version 6.
Enter the Listen Address and Request Multicast Address as required.
Select whether you require a secure connection for the Test, Configure,
and Diagnostic Tools.
Press Apply.
Only Display Specific
Reader Models
Select Options→Filter
Options→Filter
to view only specific
reader models.
28
3M Toll RFID Reader 6204 User’s Guide
1 2
6.4.
Reader Startup Tool
View or Change the Reader’s Network Settings
From the RST main page, press the
Verify the IP Address, Subnet, and Default Gateway are correct.
If Method: DHCP is selected these fields will be locked.
If required, change the values.
3M Toll RFID Reader 6204 User’s Guide
button.
29
1 2
6.5.
Reader Startup Tool
Reader Test Tool (RTT)
The Reader Test Tool (RTT) is primarily designed for new users to test
reader operation and perform a few basic reader functions. With RTT, you
can perform the following:
Read tags
Issue commands to the reader and view the responses
Run macros
Observe reader events
 To access the Reader Test Tool, select a reader and press
on
the RST tool bar or select Test from the Tools pull-down menu.
6.5.1.
General Page
The General Page allows you to issue commands to the reader and view
any responses. From the pull-down menus, you can also login to the reader,
change the operating mode, select another protocol, and select which
antennas are active.
30
3M Toll RFID Reader 6204 User’s Guide
1 2
Reader Startup Tool
Login to Reader
To login to the reader, perform the following:
From the pull-down menu, select Reader→Login….
Select the type of Login from the pull down. The default login is guest. If
you need administrator privileges, login as admin.
Enter your Password. Enter readeradmin as the password if you logged
in as admin.
Press OK.
Default Admin
Password
3M recommends
changing the default
Admin password once
installation,
configuration, and
testing are complete.
Select Operating Mode
From the pull-down menu, select Operating Mode→
or, press the Operating Mode select button on the left side of the tool bar.
 Active – Reader is continuously attempting to singulate tags and
automatically reports any singulated tag via an asynchronous event
notification on the event channel.
 Standby – Reader is not transmitting any RF energy, unless processing
a tag related command. The transmitter is enabled at the beginning of
the command processing, protocol operations required for the
command are performed, and then the RF transmitter is turned off.
3M Toll RFID Reader 6204 User’s Guide
31
1 2
Reader Startup Tool
Select Protocol
NOTE
Certain protocols
require licensing and
may not be available.
Contact 3M for more
information.
You can activate one or more protocols on the 6204 using RST. From the
pull-down menu, select Protocols→. Active protocols are
indicated by
Antenna Selection
You can select the ports that have antennas connected and which antennas
are active. Perform the following:
1 From the pull-down menu, select Antennas→. Active antennas
are indicated by .
32
You can also select the order in which antennas are activated. From the
pull-down menu, select Antennas→Mux sequence....
Enter the antenna numbers in the order to be activated.
Press OK.
3M Toll RFID Reader 6204 User’s Guide
1 2
Reader Startup Tool
Set Reader Options
You can setup other reader options including help type macro highlighting.
From the pull-down menu, select Edit→Options.
3M Toll RFID Reader 6204 User’s Guide
33
1 2
6.5.2.
Reader Startup Tool
Tag Performance Page
The Tag Performance page is used to test the reader performance.
To initiate a timed test, enter the length of test (in ms) into the Total Query
Time field. For example, to verify to number of tags read in a 30-second
interval, select Active Operating Mode, enter 30000, and press the Start
button. The test will complete after 30 seconds and the output statistics are
updated for the query time.
Output statistics are read-only and include: Total Unique Tags, Tag Read
Count, Cumulative Rate, and Current Rate.
Detailed descriptions of the various Tag Performance fields and functions
are provided in the following sections.
Tag read controls are provided by the Tag Database Query and Scan
Operation blocks. Use the Query controls when the reader is in Active
mode. Use the Scan Operation controls when in Standby mode.
Tag and reader performance data is provided in the Performance
Information and Tag Acquisition Analysis blocks.
34
3M Toll RFID Reader 6204 User’s Guide
1 2
Reader Startup Tool
Performance Information
Total Unique Tags – Number of unique tags in the tag database.
Tag Read Count – Total number of tags read (including repeat reads).
Cumulative Rate – Cumulative read rate in tags/second since the Start
button was pressed.
Current Rate – Current read rate in tags/second.
Tag Database Query Controls
Click to retrieve the current information from reader’s
tag database.
Click to query the tag database every Query Interval
(ms) for a total time of Total Query Time (ms). Do
not set the interval less than 500. If Total Query Time
is set to 0, query continues indefinitely.
Click to stop automatic query.
Indicates current read rate with audible tone.
Check to purge the reader’s tag database after each
query. Refer to the 3M Toll RFID Reader 6204
Protocol Reference Guide for more information on
the tag database.
Tag Acquisition Analysis
The Tag Acquisition Analysis fields provide the minimum, maximum, and
average number of times each tag was read. For example, assume five tags
(A, B, C, D, and E) are read 107, 59, 223, 187, and 94 times respectively.
The displayed values are as follows:
Min = 59
Avg = 134
Max = 223
Scan Operation
Scan time (ms) – Enter the duration of reader operation in milliseconds.
After this time expires, the tag information is displayed.
Press this button to activate the reader.
Purge and Clear Reader Statistics
Select the reader and then select Edit→Purge and Clear Statistics.
3M Toll RFID Reader 6204 User’s Guide
35
1 2
6.5.3.
Reader Startup Tool
Tag Management Page
The Tag Management page is used for reading individual fields on a single
tag as well as writing the access password and locking a tag. The Read
button will cause the reader to singulate and read a tag in the selected
antennas’ RF field. Specific fields you can read include:
Kill Code
Access Code
Tag ID
TID
User Data
Clear Read and Write Fields
To clear the Read or Write fields, select Edit→Clear….
36
3M Toll RFID Reader 6204 User’s Guide
1 2
6.5.4.
Reader Startup Tool
Macros Page
The Macros page allows the reader to manage macro files. The macros are
provided by 3M or can be written by the end user. Some of the macros
provided are dependent on the operating region of the reader.
A macro (script or command file) is a text file that contains one or more
reader commands. These commands are used to configure the reader to a
known configuration. The Macros can contain variables. These variables are
resolved by a dialog box (Macro Variables) that appears when the Send to
Reader button is selected. The syntax of a variable is:
[$variable_name]
During execution, the variable is replaced with user entries into the Macro
Variables dialog box. Macros can be edited with any text editor including
Windows Notepad.
3M Toll RFID Reader 6204 User’s Guide
37
1 2
Reader Startup Tool
Macro Input subsub-window
The Macro Input window shows the current script that will be sent to the
reader when the Send to Reader button is selected. The text in the Macro
Input window can be edited prior to being sent to the reader.
Macro Output subsub-window
The Macro Output window is updated after the Send to Reader button is
selected. Look at this window to verify that each command line in a script
executed correctly. Look for the −−>> ok response from the reader for each
command line.
Macro Variables
Variables Dialog
Dialog box
When a macro is sent to the
reader, the values for variables
must be resolved via this Windows
Dialog box. You can [tab] to each
value field and enter the desired
value.
For example, one macro can be
used for two different applications
by using variables for antenna
selection and transmit power.
Macro Example
To configure the reader for FCC, Part 90 Dense operation, send the
following macro (part90_6tari_lf640_PR_M2.mcr):
# configure region
setup.region=fcc
setup.sub_region=fcc_part90
# set frequency
setup.advanced.preferred_frequencies=915950
# configure protocol
modem.protocol.isoc.control.auto_phy.enable=false
modem.protocol.isoc.physical.set(tari=tari_06_25,
return_link_freq=LF640, data_1_length=d1_len_20,
rt_modulation=rt_mod_pr,
tr_encoding=tr_enc_miller_2,interrogator_mode=dense)
38
3M Toll RFID Reader 6204 User’s Guide
1 2
6.5.5.
Reader Startup Tool
Event Handling Page
The Event Handling page allows you to register for Reader Events. After
registration, events are displayed with the newest on the bottom and the
most recent event will scroll to the bottom of the window. Individual events
or a group of events can be registered. For detailed information on
individual events, refer to Chapter 18 – Events Namespace of the 3M Toll
RFID Reader 6204 Protocol Reference Guide.
Guide
Registering for an individual
individual event
To register for an individual event, either type the event name or select an
event from a pull-down list.
Registering for a group of events
Registering for event.error events, will cause the reader to autonomously
send all events in the event.error namespace to the RTT program and be
displayed in the window of this page. Enter event.error in the Events: field
and press the Register button. The Clear button can be selected at any
time to clear the window.
3M Toll RFID Reader 6204 User’s Guide
39
1 2
6.5.6.
Reader Startup Tool
Antenna Settings Page
The Antenna Settings page allows you to adjust the power settings for each
antenna. Only the controls for those antennas that are connected are
activated.
40
3M Toll RFID Reader 6204 User’s Guide
1 2
6.6.
Reader Startup Tool
Reader Diagnostics Tool (RDT)
The RDT is to be used by 3M trained technicians to troubleshoot and
diagnose various reader issues. Administrator login is required.
To use RDT, you must login as an administrator, perform the following.
When you first start RDT, the following login will appear:
Enter your Password. Enter readeradmin or your current administrator
password. Press OK.
6.6.1.
Channel Statistics
The Channel Stats page shows details of channel changes. This page is
typically used to observe regional behavior.
3M Toll RFID Reader 6204 User’s Guide
41
1 2
6.6.2.
Reader Startup Tool
Alarms
The Alarms page is used to capture autonomous alarms generated by the
reader during normal operation. The alarms are defined as autonomous
reader events for the following namespaces:
event.error
event.warning
42
3M Toll RFID Reader 6204 User’s Guide
1 2
6.6.3.
Reader Startup Tool
Tag Report
The Tag Report page is used to view specific information for each tag
singulation. This feature provides detailed attributes of tag singulations
such as tag power (RSSI) and on which antenna that tag singulated.
NOTICE:
NOTICE:
Use of this tool can adversely affect tag reader performance, particularly if many tag fields are
enabled. Use the RTT->Tag Performance page for normal tag performance testing.
3M Toll RFID Reader 6204 User’s Guide
43
1 2
6.6.4.
Reader Startup Tool
Spectrum Analyzer
The Spectrum Analyzer allows you to examine the spectral composition of
the radio waves in your surrounding environment. This feature provides a
graphical representation of the current spectral RF noise in units of dBm
with a range of 0 to -120 dBm. This feature is intended for expert users to
verify RF environmental conditions during an installation.
NOTICE:
NOTICE:
44
Using this feature during normal reader operation can significantly degrade tag reading
performance.
3M Toll RFID Reader 6204 User’s Guide
1 2
6.6.5.
Reader Startup Tool
Power Ramp Tool
The Power Ramp Tool determines the minimum power to activate a tag and
can help determine tag quality. This activation power level can help
determine the read range at various attenuation levels and, for AVI
applications, can help determine the "read-zone" or an antenna pattern.
The tool starts by configuring the reader to start transmitting at a high
attenuation level (usually maximum allowed for reader) and decrements the
level until it observes a response from the tag. The transmitter is turned off
and the minimum value to activate the tag for a given antenna and distance
is reported.
The Power Ramp controls include:
 Increment Rate (ms) – Time tool stays at a particular power level
before incrementing to the next power level.
 Initial Attenuation Level (dBm) – Starting attenuation level.
 Attenuation Decrement (dBm) – Step-size for attenuation
decrement.
 Antennas section allows you to select which antenna(s) to test with.
 Filter section allows you to apply a filter to only look for a particular tag.
3M Toll RFID Reader 6204 User’s Guide
45
1 2
Reader Configuration Tool
Embedded Reader Configuration Tool (RCT)
The embedded Reader Configuration Tool (RCT) allows you to access your
reader across the internet by entering the reader’s IP address into your web
browser. With the RCT, you can fully configure your reader for operation in a
variety of applications and environments. With this application, you can
perform the following:
Basic Configurations
Advanced Configurations
Check System Status
Access the online Help
To access the RCT, press the
46
button on the main RST page.
3M Toll RFID Reader 6204 User’s Guide
1 2
7.1.
Reader Configuration Tool
Basic Configuration
With the Basic Configuration functions you can perform the following:
7.1.1.
Manage reader profiles
Set tag protocols
Setup the Ethernet/LAN configuration
Setup the serial port
Setup digital accessories
Setup antennas
Set regulatory modes
Configuration Page Header
Each page displayed by the RCT has the following header.
This header provides pull-down menus for each of the configuration
function categories. Additional functions include the user login and the
currently loaded reader profile.
Login
The reader’s default user level is guest.
guest However, a user can login as admin.
If not logged in as admin,
admin the default level is always guest.
guest
The guest login level provides read-only access to the reader. Clients that
login in at the guest level can read the settings of the reader and can
access the tags that the reader has inventoried. Clients at this level cannot
change the configuration of the reader.
The admin login level provides read-write access to the reader. Clients that
login in at the admin level can read and write the settings of the reader and
can access the tags that the reader has inventoried.
Logout
After logging in as admin,
admin the Logout button logs you out of the reader.
Logging out automatically sets the login level to guest.
Profile:
Profile is the currently active profile in the reader. Refer to the Manage
Profiles section for detailed information on reader profiles.
3M Toll RFID Reader 6204 User’s Guide
47
1 2
Reader Configuration Tool
Save
The Save button saves the reader's current configuration to the specified
profile. Refer to the Manage Profiles section for detailed information on
reader profiles.
Manage Profiles
This link allows you to list, save, and delete profiles. Refer to the Manage
Profiles section for detailed information on reader profiles.
7.1.2.
Manage Profiles
The reader’s configuration is stored in a profile. A profile contains the
setting of all the configuration variables in the reader. The reader can
support up to 8 unique profiles. Detailed information about reader profiles
is provided in Chapter 4 – Reader Behavior of the 3M Toll RFID Reader
6204 Protocol
Protocol Reference Guide.
Guide
The Manage Profiles page provides a list of all profiles stored in the reader.
Profile Names
The profile name
factory is reserved
and cannot be used.
This profile is a read
only profile.
48
Save a Profile
To save your current reader configuration under a new profile, enter a
profile name and press Save. The new profile will appear in the Profile
Name list. Profile names must consist of the characters A - Z, a - z, 0 - 9, '-'
or '_' and must be between 1 and 32 characters in length. The reader can
store up to 8 different profiles.
3M Toll RFID Reader 6204 User’s Guide
1 2
Reader Configuration Tool
Activate a Profile
Profile
To activate a previously saved profile, press the Activate button beside the
profile name. The selected profile will be loaded into the reader.
Delete a Profile
To delete a previously saved profile, press the Delete button beside the
profile name. This is a destructive operation. Once a profile is deleted, it
cannot be recovered.
Reset to Factory Default
In addition to managing reader profiles, you can also reset the reader back
to its factory default configuration. From the Profiles page select one or
more of the following:
 Stop All Embedded Applications – This option terminates any
embedded applications currently running on the reader.
 Reset Serial Port – This option resets the serial port configuration to
the factory default settings.
 Reset Network Interface Configuration – This option resets the network
configuration to factory defaults.
NOTICE:
NOTICE:
Resetting the 3M Toll RFID Reader 6204 to Factory Default will reboot the reader.
3M Toll RFID Reader 6204 User’s Guide
49
1 2
7.1.3.
Reader Configuration Tool
Set Tag Protocol
This Set Tag Protocol page consists of two forms. The first form (top) allows
you to select which type of tags the reader will acquire or the type of
protocol(s) to utilize on the air interface.
Select the check box for the protocol(s) to enable and then press Enable
Selected Protocols to activate the protocol.
Click on a specific protocol to view the lower form. This form allows you to
configure various protocol level parameters. The protocol level parameters
are divided into two categories: control and physical. Control parameters
configure the protocol control. Physical parameters configure the physical
air interface for the protocol.
For detailed information on each of the Control and Physical parameters,
refer to Chapter 15 – Modem Namespace of the 3M Toll RFID Reader 6204
Protocol Reference Guide. Parameter descriptions are provided in the
modem.protocol.isoc.control and modem.protocol.isoc.physical
configuration variable sections.
50
3M Toll RFID Reader 6204 User’s Guide
1 2
7.1.4.
Reader Configuration Tool
Setup Ethernet/LAN
The Setup Ethernet/LAN page allows you to configure the network interface
of the reader.
NOTE:
Always record the
IP, Mac, subnet,
and default
gateway addresses
for your readers
and keep this data
in a safe location.
You can use this
data to reconfigure
the network in the
event of application
failure or data loss.
3M Toll RFID Reader 6204 User’s Guide
51
1 2
Reader Configuration Tool
General Settings allow you to specify the host and domain name of the
reader. The Command and Event Ports are also shown. You can also select
your domain name in this window.
IPv4/IPv6 Settings allow you to configure the reader’s IP address. If the
reader is to automatically acquire its IP address, subnet mask and default
gateway from a DHCP server, select Enable DHCP. To manually specify this
information, deselect Enable DHCP and fill in the desired IP address,
subnet mask and default gateway.
Other Settings allow you to configure the NTP servers the reader can
contact to obtain the current time, DNS servers the reader can contact for
domain name resolution, and the Domain list to resolve names to IP
addresses.
Enter all the required information and press Submit.
7.1.5.
Setup Serial Port
The Setup Serial Port function allows you to configure the serial port
parameters. These parameters include:
Baud rate
Data bits
Parity
Echo
Stop bits
Use the pull-down menus to select a value and press Submit to update the
reader.
52
3M Toll RFID Reader 6204 User’s Guide
1 2
7.1.6.
Reader Configuration Tool
Setup Digital Accessories
The Setup Digital Accessories function allows you to configure the Digital
Inputs and Outputs on the reader.
Digital Input
The status of the four digital input values (1–4) can be seen in this window.
The Current Value is not configurable and is shown as true or false. The
Debounce value can be set and is in milliseconds.
Digital Output
The output value for each digital output can be set to true or false. Press
the Submit button to send the appropriate commands to the reader to
update the digital inputs and outputs.
Refer to the 3M Toll RFID Reader 6204 Protocol
Protocol Reference Guide for more
information on configuring the digital inputs and outputs.
3M Toll RFID Reader 6204 User’s Guide
53
1 2
7.1.7.
Reader Configuration Tool
Setup Antenna/Cables
This page allows you to configure the reader’s antenna multiplexer
sequence as well as conducted power. For detailed descriptions of each of
the antenna and cable variables, refer to Antenna Configuration in Chapter
4 – Reader Behavior of the 3M Toll RFID Reader 6204 Protocol
Protocol Reference
Guide.
Guide
To configure an antenna, enter the antenna number in the Mux Sequence
field. The individual antenna Conducted Power fields will be activated in
the lower window. The current values will be displayed. Only those antennas
listed in the Mux Sequence will be shown. Also, you must set Conducted
Power to 0 in order to set or change the Attenuation, Cable Loss, or Gain.
To change, enter the appropriate values for each antenna parameter and
press the Submit button to update the antenna and cable configuration.
Select the next antenna and repeat.
54
3M Toll RFID Reader 6204 User’s Guide
1 2
Reader Configuration Tool
ADDITIONAL ANTENNA NOTES:
1. The required antenna impedance is 50 ohms.
2. To reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (EIRP) is not more than that required for
successful communication.
3. The installer of this radio equipment must ensure that the antenna is located or pointed such that it
does not emit an RF field in excess of Health Canada limits for the general population; consult Safety
Code 6, obtainable from Health Canada’s website at:
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct/index-eng.php.
4. Additional details for the approved antennas for the 3M Toll RFID Reader 6204 can be found in
Section 9.1.7., 3M Toll RFID Reader 6204 Antenna Specifications.
Specifications
7.1.8.
Set Regulatory Mode (Region)
This page allows the user to configure the reader to meet the regulatory
requirements for the geographic region where the reader is deployed. The
sub-region sets the secondary regulatory mode for the geographic region
where the reader is deployed.
For detailed information on each of these parameters, refer to the 3M Toll
RFID Reader 6204 Protocol
Protocol Reference Guide.
Guide Descriptions are provided in
the setup.region and setup.sub_region configuration variable
sections.
7.1.9.
Setup Summary
This page allows you to quickly setup the basic operational parameters of
the reader.
3M Toll RFID Reader 6204 User’s Guide
55
1 2
7.2.
Reader Configuration Tool
Advanced Functions
With the Advanced Functions you can perform the following:
56
Firmware Management
Import/Export Configuration
Command Line operations
Expert Configuration
User Application Management
Change Operating Mode
Restart
View and edit the Wiegand Translation Table
3M Toll RFID Reader 6204 User’s Guide
1 2
7.2.1.
Reader Configuration Tool
Firmware Management
This page allows you to perform the following:
Read the current reader firmware version
Upgrade the reader firmware files
Rollback to the previous reader firmware version
Upgrade Wiegand component firmware files (note you cannot rollback
the Wiegand firmware)
 Update the LLRP Component update file and to update the LLRP
Component firmware on the reader.
Enter the name of the 3M provided firmware file in the Firmware File field.
Use the Browse button to help locate the file.
The Rollback Firmware button will roll back the reader firmware to the
previous version.
3M Toll RFID Reader 6204 User’s Guide
57
1 2
7.2.2.
Reader Configuration Tool
Import/Export Configuration
This page allows you to transfer a reader configuration to or from your host
computer. This is useful for configuring a reader to a known state.
58
3M Toll RFID Reader 6204 User’s Guide
1 2
Reader Configuration Tool
Import Configuration to Reader
Enter the name of a saved configuration file in the Configuration file field.
Select the XML File option and press the Transfer Configuration to Reader
button to send the profile to the reader.
Export Configuration from Reader
This function is used to export the current reader settings for later
uploading. Press the XML Format button to view the XML file in the browser.
Save this file to your computer if you wish retain it for future.
If you wish to view the current configuration parameters for a reader, press
Text Format button.
3M Toll RFID Reader 6204 User’s Guide
59
1 2
Reader Configuration Tool
Import Licenses
This function is used to import a feature license file. Navigate to the license
file and press Import License to load the file into the reader.
Import Security Keys
This function is used to import reader security keys to the reader. Navigate
to the key file and press Import Security Keys to load the file into the
reader.
Export Security Keys
This function is used to export reader security keys from the reader. Enter
the commissioning password and the mac address file containing a list of
readers (each number followed by a carriage return) to allow import of these
keys. Navigate to the mac address file and press Export Security Keys to
load the file into the reader.
Import Wiegand Translation Table
This function is used to import a Wiegand translation table to the reader.
The file will typically have a .csv extension.
Export Wiegand Translation Table
This function is used to export a Wiegand translation table from the reader.
The file extension will default to .csv.
Import Application Package
This function is used to import a set of user applications, along with each
application's arguments and autostart status.
Export Application Package
This function is used to export the user applications, along with each
application's arguments and autostart status.
60
3M Toll RFID Reader 6204 User’s Guide
1 2
7.2.3.
Reader Configuration Tool
Command Line
This page allows you to directly enter reader commands from your web
browser.To directly enter commands from the Command Line Interface
(CLI), refer to the 3M Toll RFID Reader 6204 Protocol
Protocol Reference Guide.
Guide
3M Toll RFID Reader 6204 User’s Guide
61
1 2
7.3.
Reader Configuration Tool
Expert Configuration
The Expert Configuration functions allow you to configure low-level functions
within the reader. These functions should only accessed by expert users.
Expert configurations include:
NOTE
For details on
reader variables,
refer to the 3M Toll
RFID Reader 6204
Protocol Reference
Guide.
7.3.1.
Setup
Tag
Version
Information
Communication
Antennas
Digital I/O
Security
Writeback
Modem
Expert Configuration – Setup
This page allows you to set the basic operating parameters of the reader
including region, sub region, mode, and active protocols. You can also view
the valid protocols and regions.
62
3M Toll RFID Reader 6204 User’s Guide
1 2
7.3.2.
Reader Configuration Tool
Expert Configuration – Tag
This page allows you to configure how the reader reports tags.
NOTE
For details on tag
variables, refer to
the 3M Toll RFID
Reader 6204
Protocol Reference
Guide.
The 6204 supports the ability to filter tags or eliminate tags from being
reported based on the conditions specified in the filter configuration
variables. The reader supports eight filters and each filter is specified by the
following configuration variables:
 enabled – Enables or disables the filter.
 inclusive – Indicates to either include tags that match (Inclusive) or
include tags that do not match (Exclusive) the tag filter.
 mask – Mask (as an array of hex bytes) for the tag filter.
 name – Name given to the tag filter
 pattern – Pattern (as an array of hex bytes) for the tag filter
The following figure shows a small sample of the available variables.
3M Toll RFID Reader 6204 User’s Guide
63
1 2
7.3.3.
Reader Configuration Tool
Expert Configuration – Version
This page displays the version of reader hardware and reader software
within the reader. The version numbers are read-only and will be needed if
you contact 3M for technical support.
64
3M Toll RFID Reader 6204 User’s Guide
1 2
7.3.4.
Reader Configuration Tool
Expert Configuration – Information
This page allows you to customize the reader’s identity. You can assign
each reader a name, description, location, and zone. You can also set how
the reader reports timestamps.
3M Toll RFID Reader 6204 User’s Guide
65
1 2
7.3.5.
Reader Configuration Tool
Expert Configuration – Communication
This page allows you to customize the reader’s communication parameters.
Refer to the Setup Ethernet/LAN and Setup Serial Port sections for
additional information.
The following figure shows a portion of communication parameters
available on the reader.
NOTE
For details on
communication
parameters, refer
to the 3M Toll
RFID Reader
6204 Protocol
Reference Guide.
66
3M Toll RFID Reader 6204 User’s Guide
1 2
7.3.6.
Reader Configuration Tool
Expert Configuration – Antennas
This page allows you to configure the properties of the reader’s antenna
configuration. For detailed description of each of the antenna and cable
variables, refer to the Antenna Configuration section in Chapter 4 – Reader
Behavior of the 3M Toll RFID Reader 6204 Protocol
Protocol Reference Guide.
Guide
Enter the appropriate values for each antenna parameter and press the
Submit button to update the antenna and cable configuration. Only
Antenna 1 and common antenna variables shown.
3M Toll RFID Reader 6204 User’s Guide
67
1 2
7.3.7.
Reader Configuration Tool
Expert Configuration – Digital I/O
This page allows you to configure the digital inputs and output behavior. You
can set the digital input debounce time (in milliseconds), as well as the
input and output pin values. Refer to the 3M Toll RFID Reader 6204
Protocol Reference Guide for detailed information on each of these
variables.
68
3M Toll RFID Reader 6204 User’s Guide
1 2
7.3.8.
Reader Configuration Tool
Expert Configuration – Security
This page allows you to configure the tag.security parameters.
Refer to the 3M Toll RFID Reader 6204 Protocol
Protocol Reference Guide for
detailed information on each of these variables.
3M Toll RFID Reader 6204 User’s Guide
69
1 2
7.3.9.
Reader Configuration Tool
Expert Configuration
Configuration – Writeback
This page allows you to configure the tag.writeback parameters.
Refer to the 3M Toll RFID Reader 6204 Protocol
Protocol Reference Guide for
detailed information on each of these variables.
70
3M Toll RFID Reader 6204 User’s Guide
1 2
7.3.10.
Reader Configuration Tool
Expert Configuration – Modem
This page allows you to set the reader’s modem variables. Modem variables
are divided into the following categories:
Control
Debug
Diagnostics
Digital IO
Radio
Statistics
Refer to the 3M Toll RFID Reader 6204 Protocol
Protocol Reference Guide for
detailed information on each of these variables. The following figures show
only a small sample of the available modem configuration variables.
7.3.10.1. Modem – Control
3M Toll RFID Reader 6204 User’s Guide
71
1 2
Reader Configuration Tool
7.3.10.2. Modem – Debug
7.3.10.3. Modem – Diagnostics
7.3.10.4. Modem – Digital IO
72
3M Toll RFID Reader 6204 User’s Guide
1 2
Reader Configuration Tool
7.3.10.5. Modem – Radio
7.3.10.6. Modem – Statistics
3M Toll RFID Reader 6204 User’s Guide
73
1 2
7.4.
Reader Configuration Tool
User Application Management
This page lists any user applications currently available on the reader and if
any applications are running. This page also allows you to upload
applications to the reader.
 Running User Applications – Lists any user applications currently
running on the reader. The application name, process ID, configuration,
and status are provided. Controls are provided to view the application
file and stop the application.
 Application Transfer – This function allows you to load custom user
applications onto the reader.
 Applications available on the reader – This function allows you to view a
list of all user applications stored on the reader. Controls are provided
to view the application and delete it from the reader.
 Start Applications – This function allows you to start Python and Java
applications.
74
3M Toll RFID Reader 6204 User’s Guide
1 2
7.5.
Reader Configuration Tool
Change Operating Mode
This page allows you to configure the operational mode of the reader.
The reader supports the following operational modes:
 Active Mode - Reader is continuously attempting to singulate tags and
automatically reports any singulated tag via an asynchronous event
notification on the event channel.
 Stand By Mode - Reader is not transmitting any energy, unless
processing a tag related command. The RF transmitter is enabled at the
beginning of the command processing, any protocol operations required
for the command are performed, and then the RF transmitter is turned
back off.
3M Toll RFID Reader 6204 User’s Guide
75
1 2
7.6.
Reader Configuration Tool
Wiegand Translation Table
This page allows you to view and edit the Translation Table used for
Wiegand operation and also for the Standalone Access Control script.
The table is only displayed when the Wiegand component is active (when
com.wiegand.enable is set to true). Buttons allow you to edit existing
translation table entries, add new entries, or delete existing entries. You
must click Submit to save table changes to the reader.
The Scan For ID button may be used to operate the reader briefly and
populate the "Original Tag ID" field with the first tag ID seen. Please see
Appendix A for details on the format of the translation table.
76
3M Toll RFID Reader 6204 User’s Guide
1 2
7.7.
Reader Configuration Tool
View Tags
All tags read by the reader are stored in a database on the reader. This
page allows you to view the tags in the database as well as change the
current Operating Mode (A
Active or Stand By).
Press Start to begin displaying the tag database. This page is automatically
refreshed every five seconds. Press Get Once to update the database one
time (refresh is off). Press Purge to purge all tags from the database.
3M Toll RFID Reader 6204 User’s Guide
77
1 2
7.8.
Reader Configuration Tool
Check Reader Status
This page allows you to view the reader/system status, CPU utilization,
services, and licensed features. This information can be used by 3M
Technical Support to verify reader operation.
78
3M Toll RFID Reader 6204 User’s Guide
1 2
3M Toll RFID Reader 6204 User’s Guide
Reader Configuration Tool
79
1 2
7.9.
Reader Configuration Tool
Review Logs
This page allows you to view the reader logs. These logs can be used by 3M
Technical Support to verify reader operation. The reader logs include:
80
Reader level Logs – System level reader operation
System Level Logs – Linux logs
Firmware Update Log – System level
Reader Applications Log – User application logs
Command History Log – Recent commands sent to the reader
Wiegand Translation Logs – Logs associated with the translation
tables for the Wiegand Interface Module
3M Toll RFID Reader 6204 User’s Guide
1 2
8.1.
Configuring Digital I/Os
Configuring Digital Inputs and Outputs
Digital Inputs
Digital I/O Module
An optional Digital
I/O Module is
available for the
3M Toll RFID
Reader 6204.
Refer to Appendix A
for more
information.
8.2.
The digital inputs (DIN1 – DIN4) can be used as general purpose inputs or
to trigger the reader for tag reading. Unused or open digital inputs are
floating inside the reader.
To activate the input, pull it low (0 Vdc) with an external device or
connection to ground that can sink 2.5 mA. No voltage higher than +24 Vdc
or lower than 0 Vdc should ever be connected to the input. See Figure 5 for
an example of a typical motion sensor installed as a tag read trigger device.
Digital Outputs
The digital outputs (DOUT1 – DOUT4) can be used as general purpose
outputs, to indicate tag reading activity, or to indicate the reader is
transmitting (RF On). Digital outputs can be pulled high.
No voltage higher than +40 Vdc or lower than 0 Vdc should ever be
connected to a digital output. The reader activates the output by pulling it
low (0 Vdc) and can sink current such that power dissipation is ≤ 1W.
8.3.
Low Latency Digital Input/Output Operation
The 6204 is equipped with low-latency digital inputs and outputs. The
inputs (3 and 4) can be used by the modem to trigger low-latency events.
Two commands control these inputs as follows:
modem.dio.in.X.positive_level = Y -- if X goes high, it triggers Y
modem.dio.in.X.negative_level = Y -- if X goes low, it triggers Y
where Y can be:
NOOP (default)
ACTIVE_MODE
STANDBY_MODE
TOGGLE_MODE
ONE_ROUND (performs one inventory round, nonblock)
RUN_SCRIPT (runs series of modem commands, see the following)
3M Toll RFID Reader 6204 User’s Guide
81
1 2
Configuring Digital I/Os
Any time the RUN_SCRIPT operation is invoked, the reader will sequence
through a maximum of 10 modem commands as follows:
modem.dio.in.X.script.num_cmds = Q
modem.dio.in.X.script.cmd1 = Z
modem.dio.in.X.script.cmd2 = Z
modem.dio.in.X.script.cmd3 = Z
modem.dio.in.X.script.cmd10 = Z
where:
Q is the number of commands. Q can be 0 to 10 (maximum 10
modem commands).
Z can be any modem command
An event event.response.modem_dio_scripts dio_in=*,
cmdnum=*, resp=*** is generated after each modem command.
Digital outputs 3 and 4 can be driven by modem after setting the following:
dio.control.X = modem
Actions that triggered the output can be defined by:
modem.dio.out.X.op = Y
where Y can be:
NOOP (default)
END_OF_ROUND (generates a pulse at end of each inventory round)
ACTIVE_MODE (triggers high in active mode)
SCRIPT_RUNNING (triggers high when digital input io triggered
script is running)
ANTENNA_FAILURE (triggers high in antenna failure state)
ERROR (generates a pulse when an error occurs)
WARNING (generates a pulse when an warning occurs)
All output (level/pulse) polarity is defined by:
modem.dio.out.X.polarity = Z
where Z can be:
POSITIVE (default)
NEGATIVE
All pulse width (in µSec) is defined by:
modem.dio.out.X.pulse_width –(default 100 µSec)
82
3M Toll RFID Reader 6204 User’s Guide
1 2
Configuring Digital I/Os
Example (Input)
The following example triggers a series of modem commands, when DIO
input 4 goes high.
modem.dio.in.4.positive_level = RUN_SCRIPT
modem.dio.in.4.script.num_cmds = 3
modem.dio.in.4.script.cmd1 = "modem.antennas.perform_check()"
modem.dio.in.4.script.cmd2 = "modem.diag.current_temperature"
modem.dio.in.4.script.cmd3 = "modem.stats.tag_read"
Example (Output)
(Output)
In the following example, DIO output 3 will trigger low when the reader is in
active mode.
dio.control.3 = modem
modem.dio.out.3.op = ACTIVE_MODE
modem.dio.out.3.polarity = NEGATIVE
8.4.
Digital I/O
I/O Monitoring and Control Scripts
Several digital I/O monitoring and control scripts are provided with the
reader to allow you to monitor the digital I/Os and take specific actions.
These Python application scripts can be used as is or modified to suit your
particular application. For detailed information on loading Python scripts,
refer to Chapter 5 – Embedded Reader Applications of the 3M Toll RFID
Reader 6204 Protocol
Protocol Reference Guide.
Guide
8.4.1.
scan_trigger.py
This routine monitors the state of the digital input pin specified as the input
parameter. If the state of the pin is low, the operating mode is set to standby. If
the I/O pin state changes to high, the operating mode is set to active.
Inputs:  – (optional) Input pin number (1–4). Default is digital in 1.
 –(optional) 0 or 1. Default is trigger on 1.
Examples:
scan_trigger.py
Monitors digital input pin 1
scan_trigger.py 1
Monitors digital input pin 1
scan_trigger.py 4
Monitors digital input pin 4
scan_trigger.py 3 0
Monitors digital input pin 3, trigger on 0
3M Toll RFID Reader 6204 User’s Guide
83
1 2
8.4.2.
Configuring Digital I/Os
scan_trigger_timer.py
This routine monitors the I/O pin. When the pen goes high, the timer is started
and the operating mode is set to active. While the timer is running, I/O pin state
changes are ignored. When the timer expires, the operating mode is set to
standby. The minimum value for the timer is 10 milliseconds (ms).
Inputs:  – (optional) Output pin number (1–4). Default is output 1.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Author                          : A4AWKZZ
Create Date                     : 2014:10:28 17:53:21-04:00
Modify Date                     : 2014:11:13 17:22:30-06:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : A4AWKZZ
Creator Tool                    : PDF Architect
Metadata Date                   : 2014:11:13 17:22:30-06:00
Producer                        : PDF Architect
Document ID                     : uuid:c0c4e74c-5caf-4a4d-831c-7eefaa2442ea
Instance ID                     : uuid:bdc29c5d-c143-4d68-8251-aca81798d65b
Page Count                      : 144
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M4Z6204

Navigation menu