User Manual
EAP701 V1.00 Enterprise Access Point Quick Installation Guide EAP701 Enterprise Access Point ENGLISH Copyright Notice This document is protected by USA copyright laws and other laws. Besides, the document is the property of 4IPNET, INC. You may not copy, reproduce, distribute, publish, display, perform, or modify any part of this publication in any form or by any means without prior written permission from 4IPNET, INC. You may not alter or remove any copyright or other notice from copies of the content. All other brand and product names are claimed or registered marks of their respective companies or organizations. All rights reserved. To download up-to-date version, please visit www.4ipnet.com. Copyright © 4IPNET, INC. All rights reserved. Quick Installation Guide EAP701 Enterprise Access Point ENGLISH FCC CAUTION This equipment has been tested and proven to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ---Reorient or relocate the receiving antenna. ---Increase the separation between the equipment and receiver. ---Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ---Consult the dealer or an experienced radio/TV technician for help. The device contains a low power transmitter which will send out Radio Frequency (RF) signal when transmitting. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Copyright © 4IPNET, INC. All rights reserved. ii Quick Installation Guide EAP701 Enterprise Access Point ENGLISH CE CAUTION Declaration of Conformity with Regard to the 1999/5/EC (R&TTE Directive) for European Community, Switzerland, Norway, Iceland, and Liechtenstein Model: EAP701 For 2.4 GHz radios, the device has been tested and passed the requirements of the following standards, and hence fulfills the EMC and safety requirements of R&TTE Directive within the CE marking requirement. • Radio: EN 300.328: • EMC: EN 301.489-1, EN 301.489-17, • EMC: EN 55022 Class B, EN 55024:+ A1 + A2 including the followings: EN 61000-3-2, EN 61000-3-3. EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 • Safety: EN 60950-1 + A11, Caution: This declaration is only valid for configurations (combinations of software, firmware, and hardware) provided and supported by 4ipnet Inc. The use of software or firmware not provided and supported by 4ipnet Inc. may result in the equipment no longer being compliant with the regulatory requirements. European standards dictate maximum radiated transmit power of 100mW EIRP and frequency range 2.400-2.4835 GHz. This equipment is intended to be used in all EU and EFTA countries. Outdoor use may be restricted to certain frequencies and/or may require a license for operation. Contact your local regulatory authority for compliance. Taiwan NCC Statement 根據 NCC 低功率電波輻射性電機管理辦法 規定: 第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或 變更原設計之特性及功能。 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時應立即停用,並改善至 第十四條 無干擾時方得繼續使用。 前項合法通信,指依電信法規定作業之無線電通信。 低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之擾。 Copyright © 4IPNET, INC. All rights reserved. iii Quick Installation Guide EAP701 Enterprise Access Point ENGLISH Preface Package Contents The 4ipnet EAP701 Wall Jack Access Point is an 1. 4ipnet EAP701 x 1 in/on-the-wall as well as a ceiling-mounted Wi-Fi 2. Quick Installation Guide (QIG) x 1 IEEE 802.11b/g/n 2.4GHz 2 X 2 MIMO access point, 3. Power Adapter (DC 5V) x 1 (Optional) designed to blend into a working or a living 4. Mounting Screws x 2 environment practically and elegantly with its 5. Surface Mounting Panel x 1 simplistic yet sleek design. 6. Outlet Mounting Panel x 1 The compact EAP701 in a small form factor lays 7. Mounting Plate Unfastening Tool x 1 snug in a standard wall outlet box. Its side panel features LED status indicators and two RJ45 ports. It has the interfaces to serve both wireless and wired LAN access. When coupled with the 4ipnet WHG series Controller, the EAP701 supports Tunnel-based AP Management, and comes with all standards demanded by enterprise applications, including business-grade security (802.1X, WPA and WPA2), and multiple ESSIDs with VLAN tags to separate the traffics of different departments. A centralized WLAN management allows enterprises and organizations to support a wide array of value added applications, bandwidth control, patent-pending such and as load access 4ipWES balancing, control. The (Press-n-Connect) technology bridges multiple EAP701s at the touch of a button, which enables a quick and automatic WDS Easy Setup by pressing the WES button on EAP701. Extending wireless network coverage is a breeze, be it across conference rooms or along hallways. EAP701’s high performance, security and optimal invisibility make it a perfect choice of wireless connectivity for your business. Copyright © 4IPNET, INC. All rights reserved. It is recommended to keep the original packing material for possible future shipment when repair or maintenance is required. Any returned product should be packed in its original packaging to prevent damage during delivery. Quick Installation Guide EAP701 Enterprise Access Point ENGLISH System Overview Lower Panel EAP701 Lower Panel Attach Ethernet cables here to connect to the wired local network. 1 LAN 1 – 2 Ports 2 DC Jack 5V 2A Attach the power adaptor here. Upper Panel EAP701 Upper Panel 1 Restart / Reset Button Press once to restart the system; Press and hold for more than 5 seconds to reset to factory default. 2 LED Indicators 4 LED lights. Representation is listed at the top of the panel. WDS Easy Setup. Press the button to build up a WDS link with another WES Button peer. Copyright © 4IPNET, INC. All rights reserved. Quick Installation Guide EAP701 Enterprise Access Point ENGLISH Back Panel EAP701 Lower Panel 1 110 Punchdown Block Copper wire punch down for in-wall application 2 Uplink (PoE) Port For Uplink connection. This port can be used to connect to a controller, gateway, or directly to the internet. PoE is supported. Copyright © 4IPNET, INC. All rights reserved. Quick Installation Guide EAP701 Enterprise Access Point ENGLISH Hardware Installation Please follow the steps mentioned below to install the hardware of EAP701: Step 1. Place the EAP701 at the best location. The best location is usually at the center of your intended wireless network. The EAP701 supports two types of mounting; a) Surface Mounting Panel a) b) Outlet Mount Panel Surface Mount: Mountable on any flat surface. You may choose to connect your uplink cable the slit on the side or in through the back. b) Wall Outlet Mount: This Wall Outlet mount can be fitted on any US standard outlet box. Secure the mounting plate on the mounting surface by tightening the screws (included) at the highlighted area below: Copyright © 4IPNET, INC. All rights reserved. Quick Installation Guide EAP701 Enterprise Access Point ENGLISH Step 2. Connect one end of the Ethernet cable to the Uplink port and the other end of the cable to a switch, a router, or a hub; Or use the 110 punchdown block as your uplink connection. The 110 punchdown block may be connected with the following pin assignment: Orange Blue White Orange White Blue Brown Green White Brown White Green The EAP701 is now connected to your existing wired LAN network. Step 3. There are three ways to supply power to EAP701 a) Connect the DC power adaptor to the power jack socket. b) The Uplink port is capable of receiving PoE. Connect an IEEE 802.3af-compliant PSE device (e.g. a PoE-switch) to the Uplink port of EAP701 with the Ethernet cable. c) Use a standard 110 punchdown tool to punch copper wires onto the punchdown block (pin assignment 568A) Step 4. Fasten the Access Point to the mounting plate a) Align the Access Point to the mounting plate using the arrow printed on the back of the Access Point. Copyright © 4IPNET, INC. All rights reserved. Quick Installation Guide EAP701 Enterprise Access Point ENGLISH b) b) Align the Access Point to the 4 hooks and snap Access Point to the mounting plate c) To detach Access Point from the mounting plate, insert the Unfastening Tool (provided) horizontally into the slit, turn counter-clockwise and slide the Access Point towards the unfastening tool: Now, the Hardware Installation is complete. Punch down tools may vary by country. Please contact the 4ipnet Support Team for recommendations if needed. Please use only the power adapter supplied with the package. Using a different power adapter may damage this system. To verify the wired connection between the AP and your switch / router / hub, please also check the LED status indicator of the respective network devices. Copyright © 4IPNET, INC. All rights reserved. Quick Installation Guide EAP701 Enterprise Access Point ENGLISH Getting Started 4ipnet EAP701 supports web-based configuration. When hardware installation is complete, EAP701 can be configured through a PC by using a web browser such as Mozilla Firefox 2.0 or Internet Explorer version 6.0 and above. The default values of LAN IP address and subnet mask of EAP701 are: IP Address: 192.168.1.1 Subnet Mask: 255.255.255.0 Steps: 1. To access the Web Management Interface, connect the administrator PC to the LAN port of EAP701 via an Ethernet cable. Then, set a static IP address on the same subnet mask as EAP701 in TCP/IP of your PC, such as the following example: IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 2. Launch the web browser on your PC by entering the IP address of EAP701 (http://192.168.1.1) at the address field, and then press Enter. 3. The following Admin Login Page will appear. Enter “admin” for both the Username and Password fields, and then click Login. Administrator Login Page Copyright © 4IPNET, INC. All rights reserved. Quick Installation Guide EAP701 Enterprise Access Point ENGLISH 4. After a successful login to EAP701, a System Overview page of the Web Management Interface will appear, as depicted below. The Radio Status and AP Status will be shown. The Web Management Interface - System Overview Page 5. To logout, simply click on the Logout button at the upper-right corner of the interface to return to the Administrator Login Page. Click OK to logout. Copyright © 4IPNET, INC. All rights reserved. Quick Installation Guide EAP701 Enterprise Access Point ENGLISH Common Settings Step 1. Change Administrator’s Password Change Password Page Click on the Utilities icon on the main menu, and select the Change Password tab. Enter the old password and then a new password with a length of up to 32 characters, and retype it in the Re-enter New Password field. Click SAVE to save the changes. Copyright © 4IPNET, INC. All rights reserved. Quick Installation Guide EAP701 Enterprise Access Point ENGLISH Step 2. Configure General AP (Access Point) Settings Wireless General Settings Page Click on the Wireless icon on the main menu, and then select the General tab. Select the RF card you would like to set up. Determine the Band and Channel settings: Select your preferred Band and Channel for you wireless connection. For example, select 802.11g+802.11n for the band and 6 for the channel. Copyright © 4IPNET, INC. All rights reserved. 10 Quick Installation Guide EAP701 Enterprise Access Point ENGLISH Step 3. Configure VAP (Virtual Access Point) Profile Settings VAP Configuration Page (VAP-1 shown) The EAP701 supports up to 8 virtual APs (VAPs). Configure VAP profile settings: (a) Select the VAP Configuration tab to configure the settings of the desired VAP. (b) Choose a specific RF card to set up (c) Enable a selected VAP from the drop-down menu of Profile Name and configure related settings below. (d) Check “CAPWAP Tunnel Interface” if you would like data of this VAP to go through the Controller when the Access Point is managed by CAPWAP. Check VAP status: After finishing VAP configuration, the status of the enabled Virtual APs shall be reflected on the VAP Overview page – at Wireless > VAP Overview. Copyright © 4IPNET, INC. All rights reserved. 11 Quick Installation Guide EAP701 Enterprise Access Point ENGLISH Virtual AP Overview Page Step 4. Configure WDS (Wireless Distribution System) Settings (Optional) To extend the wireless coverage, EAP701 supports up to 4 WDS links for connecting wirelessly to other WDS-capable APs, or peer APs. By default, all WDS profiles are disabled. Copyright © 4IPNET, INC. All rights reserved. 12 Quick Installation Guide EAP701 Enterprise Access Point ENGLISH Click on the Wireless button on the main menu. Select the Repeater tab. Choose WDS as the Repeater Type. Choose the desired RF card and WDS profile: (a) Enable WDS. (b) Enter the MAC Address (peer AP) and then Click SAVE. If you are using another EAP701 as the peer AP, simply repeat the above-mentioned steps to configure another peer AP(s). Note: On each and every configuration page, you may click SAVE to save the changes of your configured settings, but you must reboot the system for the changes to take effect. After clicking SAVE, the following message will appear: “Some modifications have been saved and will take effect after Reboot.” Congratulations! Now, 4ipnet EAP701 is installed and configured successfully. After EAP701's network configuration is completed, please remember to change the IP Address of your PC Connection Properties back to its original settings in order to ensure that your PC functions properly in its real network environments. It is strongly recommended to back up your configuration settings. For further configuration and information, please refer to the User’s Manual. P/N: V10020141229 Copyright © 4IPNET, INC. All rights reserved. 13
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Warning : Invalid xref tableEXIF Metadata provided by EXIF.tools