4IPNET 180002 Enterprise Access Point User Manual QIG
4IPNET, INC. Enterprise Access Point QIG
4IPNET >
User Manual
Handbook EAP740 Enterprise Access Point Handbook EAP740 Enterprise Access Point ENGLISH Copyright Notice This document is protected by USA copyright laws and other laws. Besides, the document is the property of 4IPNET, INC. You may not copy, reproduce, distribute, publish, display, perform, or modify any part of this publication in any form or by any means without prior written permission from 4IPNET, INC. You may not alter or remove any copyright or other notice from copies of the content. All other brand and product names are claimed or registered marks of their respective companies or organizations. All rights reserved. To download up-to-date version, please visit www.4ipnet.com. Copyright © 4IPNET, INC. All rights reserved. Handbook EAP740 Enterprise Access Point ENGLISH FCC CAUTION This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible. This device is restricted to indoor use when operated in the 5.15 to 5.25 GHz frequency range. ※ FCC requires this product to be used indoors for the frequency range 5.15 to 5.25 GHz to reduce the potential for harmful interference to co-channel Mobile Satellite systems. IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 42cm between the radiator & your body. Copyright © 4IPNET, INC. All rights reserved. ii Handbook EAP740 Enterprise Access Point ENGLISH CE CAUTION Hereby, 4ipnet, inc. declares that the radio equipment type EAP740 is in compliance with Directive 2014/53/EU. Frequency Range and Transmit Power Frequency range (MHz) Max. transmit power (dBm) 2412-2472 20 dBm 5150-5350 23 dBm 5500-5700 30 dBm AT BE BG HR CY CZ DK EE FI FR DE EL HU IE IT LV LT LU MT NL PL PT RO SK SI ES SE UK This device is restricted to indoor use. Input Power Operation Temperature Power from PoE: IEEE802.3at 0℃ (32℉) to 50℃ (122℉) Model - EAP740 The device has been tested and passed the requirements of the following standards, and hence fulfills the EMC and safety requirements of RED within the CE marking requirement. Radio: EN 300 328 V2.1.1, EN 301 893 V2.1.1 EMC: EN 301 489-1 V2.1.1, EN 301 489-17 V3.1.1 EMC: EN 55032:2015 + AC:2016 Class B, EN 55024:2010 + A1:2015 including the followings: EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 Safety: EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 Caution This declaration is only valid for configurations (combinations of software, firmware, and hardware) provided and supported by 4ipnet Inc. The use of software or firmware not provided and supported by 4ipnet Inc. may result in the equipment no longer being compliant with the regulatory requirements. Requirements in AT/BE/BG/CZ/DK/EE/FR/DE/IS/IE/IT/EL/ES/CY/LV/LI/LT/LU/HU/MT/NL/NO/PL/PT/RO/SI/SK/TR/FI/SE /CH/UK/HR. 5150MHz ~ 5350MHz is for indoor use only. In order to ensure compliance with the exposure recommendations to electromagnetic fields, the device should be used at a minimum distance of 42cm from the body. Copyright © 4IPNET, INC. All rights reserved. iii Handbook EAP740 Enterprise Access Point ENGLISH Taiwan NCC Statement 根據 NCC 低功率電波輻射性電機管理辦法 規定: 第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、 加大功率或變更原設計之特性及功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即 停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通 信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。 在 5.25 ~ 5.35 秭赫頻帶內操作之無線資訊傳輸設備,限於室內使用。 For UNII 產品 (5GHz WLAN/WIFI) [警語內容] 使用此產品時應避免影響附近雷達系統之操作。 MPE [警語] 「電磁波曝露量 MPE 標準值 1mW/cm2,本產品使用時建議應距離人體 42 cm」 減少電磁波影響,請妥適使用 Copyright © 4IPNET, INC. All rights reserved. iv Handbook EAP740 Enterprise Access Point ENGLISH Preface Package Contents 4ipnet EAP740 is a high-end, dual radio 802.11 b/g/n + ac (Wave 2) MIMO Access Point (AP) with the best performance for business and industrial applications and is compliant with the latest 1. 4ipnet EAP740 x 1 2. Handbook x 1 3. Mounting Kit x 1 4. Power Adaptor (12V) x 1 industrial wireless security standards that are required in the tightly secured enterprise network environments. EAP740 makes the wireless communication fast, secure and easy. It supports business grade security such as 802.1X, and Wi-Fi Protected Access (WPA and WPA2). The EAP740 supports multiple point-to-point wireless links to form wider wireless network coverage. EAP740 also features multiple ESSIDs with VLAN tags and multiple Virtual APs; great for enterprise applications, such as separating traffic from different departments using different ESSIDs. The PoE Uplink port is able to receive power from Power over Ethernet (PoE) sourcing devices. This handbook provides instructions and reference materials to get you started with 4ipnet EAP740. Copyright © 4IPNET, INC. All rights reserved. It is recommended to keep the original packing material for possible future shipment when repair or maintenance is required. Any returned product should be packed in its original packaging to prevent damage during delivery. Handbook EAP740 Enterprise Access Point ENGLISH System Overview EAP740 Front View EAP740 Side View EAP740 Side View Copyright © 4IPNET, INC. All rights reserved. Handbook EAP740 Enterprise Access Point ENGLISH Power LED EAP740 status. The Status LED will start blinking when the restart/reset button is pressed. For the first 5 seconds, the LED will blink slowly (restart), and after 5 seconds, the LED will start blinking quickly (reset). 2.4G LED 2.4G Wi-Fi status. The 2.4G LED will blink when there is 2.4G traffic. 5G LED 5G Wi-Fi status. The 5G LED will blink when there is 5G traffic. Uplink LED Uplink status. The Uplink LED will light up when there is traffic passing through the Uplink port. LAN LED LAN status. The LAN LED will light up when there is traffic passing through the LAN port. 12V Uplink (PoE) Port 2A Attach power adaptor here. Offers uplink connection. This port can be used to connect to a controller, gateway, or directly to the Internet. 802.3af PoE is also supported. LAN Port The ports for connections with LAN side devices. Console Port To access EAP740 via the console interface. 10 Restart / Reset Press once to restart the system; to reset the system to factory default settings, hold for more than 5 seconds. 11 USB Port USB interface reserved for future use. Copyright © 4IPNET, INC. All rights reserved. Handbook EAP740 Enterprise Access Point ENGLISH Hardware Installation Please follow the steps mentioned below to install the hardware of EAP740: 1. Mount EAP740. (a) Mounting on a Wall 1. Set two screws in the wall 128 mm (5.0 in.) apart. 2. Slide EAP740’s wall mounting slots down onto the screws so that the unit is secure. (b) Mounting on a Ceiling T-Bar 1. Use the included screws to attach two ceiling-mount T-bar clips to the back of EAP740. 2. Push EAP740 onto the ceiling T-bar until it clicks securely in place. Copyright © 4IPNET, INC. All rights reserved. Handbook EAP740 Enterprise Access Point ENGLISH 2. Connect EAP740 to your network device. Connect one end of the Ethernet cable to the Uplink (PoE) port of EAP740 and the other end of the cable to a switch, a router, or a hub. EAP740 is then connected to your existing wired LAN network. 3. Power on EAP740. There are two ways to supply power over to EAP740. - EAP740 Uplink port is capable of receiving DC currents. Connect an IEEE 802.3af-compliant PSE device (e.g. a PoE-switch) to the Uplink port of EAP740 with the Ethernet cable. - Connect a 12V/2A adaptor to the DC power jack. If needed. Now, the Hardware Installation is complete. Using a different power adapter may damage this system. To verify the wired connection between EAP740 and you switch / router / hub, please also check the LED indicator of the respective network devices. Copyright © 4IPNET, INC. All rights reserved. Handbook EAP740 Enterprise Access Point ENGLISH Getting Started 4ipnet EAP740 supports web-based configuration. When hardware installation is complete, EAP740 can be configured through a PC by using a web browser such as Mozilla Firefox 2.0 or Internet Explorer version 6.0 and above. The default values of LAN IP address and subnet mask of EAP740 are: IP Address: 192.168.1.1 Subnet Mask: 255.255.255.0 Steps: 1. To access the Web Management Interface, connect the administrator PC to the Uplink port of EAP740 via an Ethernet cable. Then, set a static IP address on the same subnet mask as EAP740 in TCP/IP of your PC, such as the following example: IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 2. Launch the web browser on your PC by entering the IP address of EAP740 (http://192.168.1.1) in the address field, and then press Enter. Example of entering EAP740's default IP Address via a web browser 3. The following Admin Login Page will appear. Enter “admin” for both the Username and Password fields, and then click Login. Administrator Login Page Copyright © 4IPNET, INC. All rights reserved. Handbook EAP740 Enterprise Access Point ENGLISH 4. After a successful login to EAP740, a System Overview page of the Web Management Interface will appear, as depicted below. The Web Management Interface - System Overview Page 5. To logout, simply click on the Logout button at the upper right hand corner of the interface to return to the Administrator Login Page. Click OK to logout. Copyright © 4IPNET, INC. All rights reserved. Handbook EAP740 Enterprise Access Point ENGLISH Common Settings Step 1. Change Administrator’s Password Change Password Page Click on the Utilities icon on the main menu, and select the Change Password tab. Enter a new password with a length of up to 32 characters, and retype it in the Re-enter New Password field. Click SAVE to save the changes. Copyright © 4IPNET, INC. All rights reserved. Handbook EAP740 Enterprise Access Point ENGLISH Step 2. Configure General AP (Access Point) Settings Wireless General Settings Page Click on the Wireless icon on the main menu, and then select the General tab. Determine the Band, Protocol and Channel settings: Select your preferred Band, Protocol and Channel for you wireless connection. For example, select 2.4GHz for the band, 802.11g+802.11n for the protocol and 6 for the channel. Copyright © 4IPNET, INC. All rights reserved. Handbook EAP740 Enterprise Access Point ENGLISH Step 3. Configure VAP (Virtual Access Point) Profile Settings VAP Configuration Page (VAP-1 shown) Configure VAP profile settings: (a) Select the VAP Configuration tab to configure the settings of the desired VAP. (b) Enable a specific VAP from the drop-down menu of Profile Name and configure related settings below. Check VAP status: After finishing VAP configuration, the status of enabled Virtual APs shall be reflected on the VAP Overview page. Copyright © 4IPNET, INC. All rights reserved. 10 Handbook EAP740 Enterprise Access Point ENGLISH Virtual AP Overview Page Copyright © 4IPNET, INC. All rights reserved. 11 Handbook EAP740 Enterprise Access Point ENGLISH Step 4. Configure WDS (Wireless Distribution System) Settings (Optional) To extend the wireless coverage, EAP740 supports WDS links on each RF card for connecting wirelessly to other WDS-capable APs (peer APs). By default, all WDS profiles are disabled. Click on the Wireless button on the main menu. Select the Repeater Settings tab. Choose WDS as the Repeater Type. Choose the desired WDS profile: (a) Enable WDS. (b) Enter the Remote AP MAC Address (peer AP) and then Click SAVE. If you are using another EAP740 as the peer AP, simply repeat the above-mentioned steps to configure another peer AP(s). Note: On each and every configuration page, you may click SAVE to save the changes of your configured settings, but you must reboot the system for the changes to take effect. After clicking SAVE, the following message will appear: “Some modifications have been saved and will take effect after APPLY.” Copyright © 4IPNET, INC. All rights reserved. 12 Handbook EAP740 Enterprise Access Point ENGLISH Congratulations! Now, 4ipnet EAP740 is installed and configured successfully. After EAP740's network configuration is completed, please remember to change the IP Address of your PC Connection Properties back to its original settings in order to ensure that your PC functions properly in its real network environments. It is strongly recommended to make a backup copy of your configuration settings. P/N: V34320180126 Copyright © 4IPNET, INC. All rights reserved. 13
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2018:02:23 14:29:53+08:00 Creator Tool : Microsoft® Word 2013 Modify Date : 2018:02:26 10:40:52+08:00 Metadata Date : 2018:02:26 10:40:52+08:00 Format : application/pdf Creator : QIG Title : QIG Producer : Microsoft® Word 2013 Document ID : uuid:976e1e3a-aad5-47a9-8fc1-f5615b19f74c Instance ID : uuid:b00f76ef-cd87-4d2a-b2b2-b1ed81d7f341 Page Count : 18 Language : zh-TW Author : QIGEXIF Metadata provided by EXIF.tools