4RF SQ928M140 Point to Multi Point Digital Transceiver User Manual Aprisa SR Product Description

4RF Limited Point to Multi Point Digital Transceiver Aprisa SR Product Description

USERS MANUAL

                                  January 2014 Version 1.1.6
 |  1   Aprisa SR+ Product Description  Copyright Copyright © 2014 4RF Limited. All rights reserved.  This  document  is  protected  by  copyright  belonging  to  4RF  Limited  and  may  not  be  reproduced  or republished in whole or part in any form without the prior written permission of 4RF Limited.   Trademarks Aprisa and the 4RF logo are trademarks of 4RF Limited.  Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Java and all Java-related trademarks are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. All other marks are the property of their respective owners. Disclaimer Although every precaution has been taken preparing this information, 4RF Limited assumes no liability for errors  and  omissions,  or  any  damages  resulting  from  use  of  this  information.  This  document  or  the equipment may change, without notice, in the interests of improving the product. RoHS and WEEE compliance The Aprisa SR+ is fully compliant with the European Commission’s RoHS (Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment) and WEEE (Waste Electrical and Electronic Equipment) environmental directives.  Restriction of hazardous substances (RoHS) The  RoHS  Directive  prohibits  the  sale  in  the  European  Union  of  electronic  equipment  containing  these hazardous substances: lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyls (PBBs), and polybrominated diphenyl ethers (PBDEs). 4RF has worked with its component suppliers to ensure compliance with the RoHS Directive which came into effect on the 1st July 2006.   End-of-life recycling programme (WEEE) The WEEE Directive concerns the recovery,  reuse, and  recycling of electronic  and electrical equipment. Under the Directive, used equipment must be marked, collected separately, and disposed of properly. 4RF  has  instigated  a  programme  to  manage  the  reuse,  recycling,  and  recovery  of  waste  in  an environmentally  safe  manner  using  processes  that  comply  with  the  WEEE  Directive  (EU  Waste  Electrical and Electronic Equipment 2002/96/EC). 4RF invites questions from customers and partners on its environmental programmes and compliance with the European Commission’s Directives (sales@4RF.com).
2  |     Aprisa SR+ Product Description  Compliance General The Aprisa SR+ radio predominantly operates within frequency bands that require a site license be issued by  the  radio  regulatory  authority  with  jurisdiction  over  the  territory  in  which  the  equipment  is  being operated. It  is  the  responsibility  of  the  user,  before  operating  the  equipment,  to  ensure  that  where  required  the appropriate license has been granted and all conditions attendant to that license have been met. Changes  or  modifications  not  approved  by  the  party  responsible  for  compliance  could  void  the  user’s authority to operate the equipment. Equipment authorizations sought by 4RF are based on the Aprisa SR+ radio equipment being installed at a fixed  restricted  access  location  and  operated  in  point-to-multipoint  or  point-to-point  mode  within  the environmental  profile  defined  by  EN 300 019, Class  3.4.  Operation  outside  these  criteria  may  invalidate the authorizations and / or license conditions. The term ‘Radio’ with reference to the Aprisa SR+ User Manual, is a generic term for one end station of a point-to-multipoint Aprisa SR+ network and does not confer any rights to connect to any public network or to operate the equipment within any territory. Compliance European Telecommunications Standards Institute The  Aprisa  SR+  radio  is  designed  to  comply  with  the  European  Telecommunications  Standards  Institute (ETSI) specifications as follows:   12.5 kHz and 25 kHz Channel Radio performance EN 300 113-2 EMC EN 301 489 Parts 1 & 5 Environmental EN 300 019, Class 3.4 Ingress Protection code IP51 Safety EN 60950-1:2006 Class 1 div 2 for hazardous locations  Frequency band Channel size Power input Notified body 135-175 MHz 12.5 kHz, 25 kHz 12 VDC  320-400 MHz 12.5 kHz, 25 kHz 12 VDC  400-470 MHz 12.5 kHz, 25 kHz 12 VDC  450-520 MHz 12.5 kHz, 25 kHz 12 VDC
 |  3   Aprisa SR+ Product Description  Compliance Federal Communications Commission The  Aprisa  SR+  radio  is  designed  to  comply  with  the  Federal  Communications  Commission  (FCC)  Radio  47CFR part 24, part 90 and part 101 Private Land Mobile Radio Services EMC 47CFR part 15 Radio Frequency Devices, EN 301 489 Parts 1 & 4 Environmental EN 300 019, Class 3.4 Ingress Protection code IP51 Safety EN 60950-1:2006 Class 1 div 2 for hazardous locations  input 135-175 MHz 12.5 kHz, 25 kHz 12 VDC Part 90 Pending 50 kHz 400-470 MHz 12.5 kHz, 25 kHz 12 VDC Part 90 UIPSQ400M131 450-520 MHz 12.5 kHz, 25 kHz 12 VDC Part 90 Pending 896-902 MHz 12.5 kHz, 25 kHz 12 VDC Part 90 Pending 896-902 MHz 12.5 kHz, 25 kHz, 50 kHz 12 VDC Part 24 Pending   pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful  interference  when  the  equipment  is  operated  in  a  commercial  environment.  This  equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the  instruction  manual,  may  cause  harmful  interference  to  radio  communications.  Operation  of  this equipment  in  a  residential  area  is  likely  to  cause  harmful  interference  in  which  case  the  user  will  be required to correct the interference at his own expense.  216-220 MHz 12.5 kHz, 25 kHz, 12 VDC Part 90 Pending 50 kHz Part 101 928-960 MHz 12.5 kHz, 25 kHz, 12 VDC Part 24, 90 and     Pending Frequency Band* Channel size Power Authorization FCC ID NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, * The frequency bands is a generic term, it is not an indication of the exact frequencies approved by FCC.specifications as follows:
4  |     Aprisa SR+ Product Description  Compliance Industry Canada The Aprisa SR+ radio is designed to comply with Industry Canada (IC) specifications as follows:  Radio RSS-119 / RSS-134 EMC This Class A digital apparatus complies with Canadian standard ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Environmental EN 300 019, Class 3.4 Ingress Protection code IP51 Safety EN 60950-1:2006 Class 1 div 2 for hazardous locations  input 135-175 MHz 12.5 kHz, 25 kHz 12 VDC RSS-119 Pending 215-240 MHz 12.5 kHz, 25 kHz 12 VDC RSS-119 Pending 400-470 MHz 12.5 kHz, 25 kHz 12 VDC RSS-119 6772A-SQ400M131 896-902 MHz 12.5 kHz, 25 kHz 12 VDC RSS-119 Pending 896-902 MHz 12.5 kHz, 25 kHz, 50 kHz 12 VDC RSS-134 Pending 928-960 MHz 12.5 kHz, 25 kHz, 50 kHz 12 VDC RSS-119 and RSS-134 Pending   Compliance Hazardous Locations Notice  This product is suitable for use in Class 1, Division 2, Groups A - D hazardous locations or non-hazardous locations.  The following text is printed on the Aprisa SR+ fascia: WARNING: EXPLOSION HAZARD - Do not connect or disconnect while circuits are live unless area is known to be non-hazardous.  The following text is printed on the Aprisa SR+ for product where the end user is in Canada: AVERTISSEMENT:  RISQUE  D'EXPLOSION  -  Ne  pas  brancher  ou  débrancher  tant  que  le  circuit  est  sous tension, à moins qu'il ne s'agisse d'un emplacement non dangereux. Frequency Band* Channel size Power Authorization IC ID * The frequency bands is a generic term, it is not an indication of the exact frequencies approved by IC.
 |  5   Aprisa SR+ Product Description  RF Exposure Warning   WARNING: The installer and / or user of Aprisa SR+ radios shall ensure that a separation distance as given in the following table is maintained between the main axis of the terminal’s antenna and the body of the user or nearby persons. Minimum  separation  distances  given  are  based  on  the  maximum  values  of  the following methodologies: 1.  Maximum Permissible Exposure non-occupational limit (B or general public) of 47 CFR 1.1310 and the methodology of FCC’s OST/OET Bulletin number 65. 2.  Reference levels as given in Annex III, European Directive on the limitation of exposure  of  the  general  public  to  electromagnetic  fields  (0 Hz  to  300 GHz) (1999/519/EC).  These  distances  will  ensure  indirect  compliance  with  the requirements of EN 50385:2002.   Frequency (MHz) Maximum Power (dBm) Note 1 Maximum Antenna Gain (dBi) Minimum Separation Distance (m) 135 + 37 15 2.5 175 + 37 15 2.5 215 + 37 15 2.5 216.5 + 37 15 2.5 217.5 + 33 15 2.5 240 + 37 15 2.5 320 + 37 15 2.5 400 + 37 15 2.5 450 + 37 15 2.5 470 + 37 15 2.5 520 + 37 15 2.5 896 + 37 28 7.5 902 + 37 28 7.5 928 + 37 28 7.5 960 + 37 28 7.5  Note 1: The Peak Envelope Power (PEP) at maximum set power level is +41 dBm.
 Contents  |  7  Aprisa SR+ Product Description  Contents 1. Introduction ............................................................................ 11 The 4RF Aprisa SR+ Radio ...................................................................... 11 Product Overview ............................................................................... 12 Network Coverage and Capacity ....................................................... 12 Automatic Registration .................................................................. 12 Remote Messaging ........................................................................ 12 Product Features ................................................................................ 13 Functions .................................................................................. 13 Performance .............................................................................. 14 Usability ................................................................................... 14 System Gain vs FEC Coding ............................................................. 15 Architecture ...................................................................................... 16 Security ........................................................................................... 17 Interfaces ......................................................................................... 18 Antenna Interface ........................................................................ 18 Ethernet Interface ....................................................................... 18 RS-232 Interface .......................................................................... 18 USB Interfaces ............................................................................ 18 Protect Interface ......................................................................... 18 Alarms Interface .......................................................................... 18 Mounting .......................................................................................... 19 DIN Rail Mounting ........................................................................ 19 Rack Shelf Mounting ..................................................................... 21 Wall Mounting ............................................................................. 22 2. Product Options ....................................................................... 23 Interface Ports ................................................................................... 23 Protected Station ............................................................................... 24 Protected Ports ........................................................................... 24 Operation .................................................................................. 25 Switch Over ........................................................................ 25 Configuration Management ...................................................... 25 Data Driven Protected Station................................................................. 26 Operation .................................................................................. 26 Duplexer Kits ..................................................................................... 27 UHF Duplexer Kits ........................................................................ 27 VHF Duplexer Kits ........................................................................ 28 USB RS-232 Serial Port .......................................................................... 29 USB RS-232 operation .................................................................... 29
8  |  Contents   Aprisa SR+ Product Description  3. Specifications .......................................................................... 30 RF Specifications ................................................................................ 30 Frequency Bands ......................................................................... 30 Channel Sizes ............................................................................. 31 Receiver ................................................................................... 34 Transmitter ............................................................................... 37 Modem ..................................................................................... 37 Data Payload Security ................................................................... 37 Interface Specifications ........................................................................ 38 Ethernet Interface ....................................................................... 38 RS-232 Asynchronous Interface ......................................................... 39 Hardware Alarms Interface ............................................................. 40 Protection Switch Specifications ....................................................... 40 Power Specifications ............................................................................ 41 Power Supply .............................................................................. 41 Power Consumption ...................................................................... 42 Power Dissipation ........................................................................ 42 General Specifications .......................................................................... 43 Environmental ............................................................................ 43 Mechanical ................................................................................ 43 Compliance ................................................................................ 44 4. Management ........................................................................... 45 SuperVisor ........................................................................................ 45 Viewing the Aprisa SR+ Terminal Settings ............................................ 46 Configuring the Aprisa SR+ Terminal Details ......................................... 47 Configuring the Aprisa SR+ RF Network Details ...................................... 47 Configuring the Aprisa SR+ Radio Settings ............................................ 48 Command Line Interface ....................................................................... 49 SNMP .............................................................................................. 49 LED Display Panel ............................................................................... 50 Normal Operation ........................................................................ 50 Single Radio Software Upgrade ......................................................... 51 Network Software Upgrade ............................................................. 51 Test Mode ................................................................................. 51 5. Applications ............................................................................ 52 Basic point-to-multipoint application ........................................................ 52 Advanced point-to-multipoint application with repeater ................................. 53 Multi-interface point-to-multipoint application ............................................ 54 Multi-hop Daisy Chain Repeaters in LBS Mode Application ................................ 55 Pseudo Peer to Peer using Base-Repeater Application .................................... 56
  Contents  |  ix    6. Product Architecture ................................................................. 57 Product Operation .............................................................................. 57 Physical Layer ............................................................................. 57 Data Link Layer / MAC layer ............................................................ 57 Channel Access .................................................................... 57 Hop by Hop Transmission ......................................................... 58 Adaptive Coding Modulation ..................................................... 59 Network Layer ............................................................................ 60 Packet Routing ..................................................................... 60 Static IP Router .................................................................... 61 Bridge Mode with VLAN Aware .................................................. 63 VLAN Bridge Mode Description .................................................. 64 Avoiding Narrow Band Radio Traffic Overloading .................................... 66 Product Architecture ........................................................................... 68 Aprisa SR+ Radio Block Diagram ........................................................ 69 Aprisa SR+ Protected Station Block Diagram ......................................... 69 7. Contact Us .............................................................................. 70
 Introduction  |  11  Aprisa SR+ Product Description  1. Introduction  The 4RF Aprisa SR+ Radio  The  4RF  Aprisa  SR+  is  a  point-to-multipoint  digital  radio  providing  secure  narrowband  wireless  data connectivity for SCADA, infrastructure and telemetry applications. The  radios  carry  a  combination  of  serial  packet  data  and  Ethernet  data  between  the  base  station, repeater stations and remote stations. The  Aprisa  SR+  is  configurable  as  a  point-to-multipoint  base  station,  a  remote  station  or  a  repeater station.
12  |  Introduction   Aprisa SR+ Product Description  Product Overview  Network Coverage and Capacity The  Aprisa  SR+  has  a  typical  link  range  of  up  to  120  km,  however,  geographic  features,  such  as  hills, mountains,  trees  and  foliage,  or  other  path  obstructions,  such  as  buildings,  will  limit  radio  coverage. Additionally, geography may reduce network capacity at the edge of the network where errors may occur and require retransmission. However, the Aprisa SR+ uses 10W output power and Forward Error Correction (FEC)  which  greatly  improves  the  sensitivity  and  system  gain  performance  of  the  radio  resulting  in  less retries and minimal reduction in capacity. Ultimately, the overall performance of any specific network will be defined by a range of factors including the  RF  output  power,  the  modulation  used  and  its  related  receiver  sensitivity,  the  geographic  location, the  number  of  remote  stations  in  the  base  station  coverage  area  and  the  traffic  profile  across  the network. Effective network design will distribute the total number of remote stations across the available base stations to ensure optimal geographic coverage and network capacity. One base station can register and operate with up to 500 remote / repeater stations. The practical limit of remote / repeater stations that can operate with one base station is determined by a  range  of  factors  including  the  number  of  services,  the  packet  sizes,  the  protocols  used,  the  message types and network timeouts.   Automatic Registration On start-up, the remote station transmits a registration message to the base stations which responds with a registration response. This allows the base station to record the details of all the remote stations active in the network. If  a  remote  station  cannot  register  with  the  base  station  after  multiple  attempts  (RF  LED  flashing  red) within 10 minutes, it will automatically reboot. If a remote station has  registered  with the base station but then loses communication, it will automatically reboot within 2 minutes.  Remote Messaging There  are  two  message  types  in  the  Aprisa  SR+  network,  broadcast  messages  and  unicast  messages. Broadcast messages are transmitted by the base station to the remote stations and unicast messages are transmitted by the remote station to the base station. These messages are commonly referred to as uplink (unicast remote to base) and downlink (broadcast base to remote). All  remotes  within  the  coverage  area  will  receive  broadcast  messages  and  pass  them  on  to  either  the Ethernet or  serial interface.  The  RTU  determines  if the message  is intended  for it  and will accept it  or discard it.
 Introduction  |  13  Aprisa SR+ Product Description  Product Features Functions   Point-to-point (PTP) or Point-to-multipoint (PMP) operation  Licensed frequency bands: VHF 135   135-175 MHz UHF 320   320-400 MHz UHF 400   400-470 MHz UHF 450   450-520 MHz UHF 896   896-902 MHz UHF 928   928-960 MHz  Channel sizes – software selectable: 12.5 kHz 25 kHz 50 kHz  Adaptive Coding Modulation (ACM): QPSK to 64 QAM  Half  duplex  or  full  duplex  RF  operation  (full  duplex  channel  access  for  point-to-multipoint available in a future software release)  Ethernet data interface and RS-232 asynchronous multiple port options  Software selectable dual / single antenna port options (dual antenna port for external duplexers or filters)  Data encryption and authentication using 128,192 and 256 bit AES and CCM security standards  Terminal server operation for transporting RS-232 traffic over IP or Ethernet  IEEE 802.1Q VLAN support with single and double VLAN tagged and add/remove VLAN manipulation to adapt to the appropriate RTU / PLCs  QoS supports using IEEE 802.1p VLAN priority bits to prioritize and handle the VLAN / traffic types   L2/3/4 filtering for security and avoiding narrow band radio network overload  L3 Router mode with standard static IP route for simple routing network integration   L2 Bridge mode with VLAN aware for standard Industrial LAN integration  Ethernet  header  and  IP/TCP/UDP  ROCH  header  compression  to  increase  the  narrow  band  radio capacity  Ethernet and serial payload compression to increase the narrow band radio capacity  Pseudo  peer  to peer  communication  between  remote  stations  through  base-repeater  or  repeater stations  SuperVisor  web  management  support  for  element  and  sub-network  (base-repeater-remotes) management  SNMPv1/2/3 & encryption MIB supports for 4RF SNMP manager or third party SNMP agent network management  SNTP for accurate wide radio network time and date   Build-configuration / flexibility of serial and Ethernet interface ports (3+1, 2+2, 4+0)  Radio and user interface redundancy (provided with Aprisa SR+ Protected Station)  Protected Station fully hot swappable and monitored hot standby  Transparent to all common SCADA protocols; e.g. Modbus, IEC 60870-5-101/104, DNP3 or similar  Complies  with  international  standards,  including  ETSI,  FCC,  IC,  EMC,  safety  and  environmental standards VHF 220   216-220 MHz
14  |  Introduction   Aprisa SR+ Product Description  Performance  Typical  deployment  of  30  remote  stations  from  one  base  station  with  a  practical  limit  of  a  few hundred remote stations  Long distance operation  High transmit power  Low noise receiver  Forward Error Correction  Electronic tuning over the frequency band  Thermal management for high power over a wide temperature range  Usability   Configuration / diagnostics via front panel Management Port USB interface, Ethernet interface  Built-in  webserver  SuperVisor  with  full  configuration,  diagnostics  and  monitoring  functionality, including remote station configuration / diagnostics over the radio link  LED display for on-site diagnostics  Dedicated alarm port  Software upgrade and diagnostic reporting via the host port USB flash drive  Over-the-air software distribution and upgrades  Simple installation with integrated mounting holes for wall, DIN rail and rack shelf mounting
 Introduction  |  15  Aprisa SR+ Product Description  System Gain vs FEC Coding This table shows the relationship between modulation, FEC coding, system gain, capacity and coverage.   Maximum FEC coding results in the highest system gain, the best coverage but the least capacity  Minimum FEC coding results in lower system gain, lower coverage but higher capacity  No FEC coding results in the lowest system gain, the lowest coverage but the highest capacity  This table defines the modulation order based on gross capacity:  Modulation FEC Coding Capacity QPSK (High Gain) Max Coded FEC Minimum QPSK (Low Gain) Min Coded FEC  16QAM (High Gain) Max Coded FEC  QPSK No FEC  16QAM (Low Gain) Min Coded FEC  16QAM No FEC  64QAM (High Gain) Max Coded FEC  64QAM (Low Gain) Min Coded FEC Maximum  This table defines the modulation order based on receiver sensitivity:  Modulation FEC Coding Coverage QPSK (High Gain) Max Coded FEC Maximum QPSK (Low Gain) Min Coded FEC  16QAM (High Gain) Max Coded FEC  QPSK No FEC  16QAM (Low Gain) Min Coded FEC  64QAM (High Gain) Max Coded FEC  16QAM No FEC  64QAM (Low Gain) Min Coded FEC Minimum
16  |  Introduction   Aprisa SR+ Product Description  Architecture The Aprisa SR+ Architecture is based around a layered TCP/IP protocol stack:  Physical Proprietary wireless RS-232 and Ethernet interfaces   Link Proprietary wireless (channel access, ARQ, segmentation) VLAN aware Ethernet bridge   Network Standard IP Proprietary automatic radio routing table population algorithm   Transport TCP, UDP   Application HTTPS  web  management  access  through  base  station  with  proprietary  management  application software including management of remote stations over the radio link SNMPv1/2/3 for network management application software
 Introduction  |  17  Aprisa SR+ Product Description  Security  The  Aprisa  SR+  provides  security  features  to  implement  the  key  recommendations  for  industrial  control systems. The security provided builds upon the best in class from multiple standards bodies, including:  IEC/TR 62443 (TC65) ‘Industrial Communications Networks – Network and System Security’  IEC/TS  62351  (TC57)  ‘Power  System  Control  and  Associated  Communications  –  Data  and Communication Security’  FIPS PUB 197, NIST SP 800-38C, IETF RFC3394, RFC3610 and IEEE P1711/P1689/P1685  The security features implemented are:  Data encryption Counter Mode Encryption (CTR) using Advanced Encryption Standard (AES) 128, 192, 258 bit, based on FIPS PUB 197 AES encryption (using Rijndael version 3.0)  Data authentication NIST SP 800-38C Cipher Block Chaining Message Authentication Code (CBC-MAC) based on RFC 3610 using Advanced Encryption Standard (AES)  Data payload security CCM Counter with CBC-MAC integrity (NIST special publication 800-38C)  Secured management interface protects configuration  L2 / L3 / L4 Address filtering enables traffic source authorization  Proprietary  physical  layer  protocol  and  modified  MAC  layer  protocol  based  on  standardized  IEEE 802.15.4  Licensed radio spectrum provides recourse against interference  SNMPv3 with Encryption for NMS secure access  Secure USB software upgrade  Key  Encryption  Key  (KEK)  based  on  RFC  3394,  for  secure  Over  The  Air  Re-keying  (OTAR)  of  encryption keys  User  privilege  allows  the  accessibility  control  of  the  different  radio  network  users  and  the  user permissions
18  |  Introduction   Aprisa SR+ Product Description  Interfaces  Antenna Interface  2 x TNC, 50 ohm, female connectors Single or dual antenna ports (with or without the use of external duplexer/filter)  Ethernet Interface  2, 3 or 4 ports 10/100 base-T Ethernet layer 2 switch using RJ45 Used for Ethernet user traffic and radio sub-network management.  RS-232 Interface  2, 1 or 0 RS-232 asynchronous ports using RJ45 connector  Optional 1x RS-232 asynchronous port using USB host port with USB to RS-232 converter Used for RS-232 asynchronous user traffic only.  USB Interfaces  1 x Management port using USB micro type B connector Used for product configuration with the Command Line Interface (CLI).  1 x Host port using USB standard type A connector Used for software upgrade and diagnostic reporting.  Protect Interface  1x Protect interface port Used for the Protected Station operation.  Alarms Interface  1x Alarm port using RJ45 connector Used to provide 2 x hardware alarm inputs and 2 x hardware alarm outputs
 Introduction  |  19  Aprisa SR+ Product Description  Mounting  The Aprisa  SR+  has four  threaded  holes (M4)  in the  enclosure  base  and  two  holes  (5.2 mm)  through  the enclosure for mounting.  Mounting options include:   DIN rail mounting with the Aprisa SR+ DIN Rail Mounting Bracket  Rack shelf mounting  Wall mounting  Outdoor enclosure mounting  DIN Rail Mounting  The Aprisa SR+ has an optional accessory to enable the radio to mount on a standard DIN rail:  Part Number Part Description APSB-MBRK-DIN 4RF SR+ Acc, Mounting, Bracket, DIN Rail
20  |  Introduction   Aprisa SR+ Product Description  The Aprisa SR+ DIN rail mounting bracket can be mounted in four positions on a horizontal DIN rail:  Vertical Mount (vertical enclosure perpendicular to the mount)  Horizontal Mount (horizontal enclosure perpendicular to the mount)  Flat Vertical Mount (vertical enclosure parallel to the mount)  Flat Horizontal Mount (horizontal enclosure parallel to the mount)
 Introduction  |  21  Aprisa SR+ Product Description  Rack Shelf Mounting  The Aprisa SR+ can be mounted on a rack mount shelf using the four M4 threaded holes in the Aprisa SR+ enclosure base. The following picture shows two Aprisa SR+ radios mounted on 1 RU rack mount shelf.  Part Number Part Description APSB-MR19-X1U 4RF SR+ Acc, Mounting, 19" Rack Mount Shelf, 1U     WARNING: If the Aprisa SR+ is operated in an environment where the ambient temperature exceeds 50°C,  the Aprisa SR+ convection air flow over the  heat sinks  must  be considered.
22  |  Introduction   Aprisa SR+ Product Description  Wall Mounting  The Aprisa SR+ can be mounted on a wall using the two holes through the enclosure (5.2 mm diameter). Typically, M5 screws longer than 35 mm would be used.
 Product Options  |  23  Aprisa SR+ Product Description  2. Product Options  Interface Ports The standard Aprisa SR+ provides multiple interface port options for combinations of Ethernet and RS-232 serial. The product shown below is the two Ethernet ports plus two RS-232 serial ports.     Interface Port Option Part Number 4 Ethernet ports and no RS-232 serial ports APSQ-N400-SSC-HD-40-ENAA 3 Ethernet ports and 1 RS-232 serial port APSQ-N400-SSC-HD-31-ENAA 2 Ethernet ports and 2 RS-232 serial ports APSQ-N400-SSC-HD-22-ENAA
24  |  Product Options   Aprisa SR+ Product Description  Protected Station The Aprisa SR+ Protected Station is full monitored hot-standby and fully hot-swappable. The Aprisa SR+ Protected Station provides radio and user interface protection for  Aprisa SR+ radios when configured  as  a  base  station.  The  RF  ports  and  interface  ports  from  the  active  Aprisa  SR+  radio  are switched to the standby radio if there is a failure in the active radio.    Option Example  Part Number Part Description APSQ-R400-SSC-HD-22-ENAA 4RF SR+, PS, 400-470 MHz, SSC, Half Duplex, 2E2S, EN, AA  The Aprisa SR+ Protected Station is comprised of an Aprisa SR+ Protection Switch and two standard Aprisa SR+ radios mounted in a 2U rack mounting chassis.  The Aprisa SR+ Protected Station is full monitored hot-standby and fully hot-swappable. All interfaces (RF, data, etc.) are continually monitored on both the active and standby radio to ensure correct operation. The standby radio can be replaced without impacting traffic flow on the active radio. The  Aprisa  SR+  radios  can  be  any  of  the  currently  available  Aprisa  SR+  radio  frequency  bands,  channel sizes or interface port options. The Aprisa SR+ Protected Station can operate as a base station, repeater station or remote station. The protection  behaviour  and  switching  criteria  between  the  active  and  standby  radios  is  identical  for  the three configurations. By default, the Aprisa SR+ Protected Station is configured with the left hand radio (A) designated as the primary radio and the right hand radio (B) designated as the secondary radio. Each radio is configured with its own unique IP and MAC address and the address of the partner radio. On  power-up,  the  primary  radio  will  assume  the  active  role  and  the  secondary  radio  will  assume  the standby  role. If, for  some  reason,  only  one radio  is  powered  on  it  will automatically  assume  the  active role.   Protected Ports The protected ports are located on the protected station front panel. Switching occurs between the active radio ports and the standby radio ports based on the switching criteria described below. The protected ports include:  Antenna ports ANT/TX and RX (if dual antenna ports used)  Ethernet ports 1 and 2  Serial port
 Product Options  |  25  Aprisa SR+ Product Description  Operation In hot-standby normal operation, the  active  radio  carries  all RS-232 serial  and  Ethernet traffic over  the radio  link  and the  standby  radio  transmit  is on with  its  transmitter  connected to  an internal  load.  Both radios are continually monitored for correct operation including the transmitter and receiver and alarms are raised if an event occurs.  The  active  radio  sends  regular  ‘keep  alive’  messages  to  the  standby  radio  to  indicate  it  is  operating correctly.  In  the  event  of  a  failure  on  the  active  radio,  the  RF  link  and  user  interface  traffic  is automatically switched to the standby radio. The failed radio can then  be replaced in the field without  interrupting user traffic (see Aprisa SR+ User Manual).  Switch Over The switch over to the standby radio can be initiated automatically, on fault detection, or  manually via the Hardware Manual Lock switch on the Protection Switch or the Software Manual Lock from SuperVisor.  Additionally,  it  is  possible  to  switch  over  the  radios  remotely  without  visiting  the  station  site,  via  the remote control connector on the front of the Protection Switch.  Configuration Management  The  Primary  and  Secondary  radios  are  managed  with  the  embedded  web-based  management  tool, SuperVisor, by using either the Primary or Secondary IP address. Configuration changes in one of the radios will automatically be reflected in the partner radio. To ensure all remote stations are registered to the correct (active) base station, changes to the Network Table  are  automatically  synchronized  from  the  active  radio  to  the  standby  radio.  The  Network  Table is only visible on the active radio. This synchronization does not occur if the Hardware Manual Lock is active.
26  |  Product Options   Aprisa SR+ Product Description  Data Driven Protected Station The  Aprisa  SR+  Data  Driven  Protected  Station  provides  radio  and  RS-232  serial  port  user  interface protection for Aprisa SR+ radios.    Option Example  Part Number Part Description APSQ-D400-SSC-HD-22-ENAA 4RF SR+, PD, 400-470 MHz, SSC, Half Duplex, 2E2S, EN, AA  The Aprisa SR+ Data Driven Protected Station shown is comprised of two standard Aprisa SR+ dual antenna port option radios and two external duplexers mounted on 19" rack mounting shelves (as shown above). The  Aprisa  SR+  radios  can  be  any  of  the  currently  available  Aprisa  SR+  radio  frequency  bands,  channel sizes or single / dual antenna port options. By  default,  the  Aprisa  SR+  Data  Driven  Protected  Station  is  configured  with  the  left  hand  radio  (A) designated as the primary radio and the right hand radio (B) designated as the secondary radio. Each radio is configured with its own unique IP and MAC address and the address of the partner radio. On  power-up,  the  primary  radio  will  assume  the  active  role  and  the  secondary  radio  will  assume  the standby  role. If, for  some  reason,  only  one  radio  is  powered  on  it  will  automatically assume  the  active role.   Operation In normal operation, the active radio carries all RS-232 serial and Ethernet traffic over the radio link and the  standby  radio  is  unused  with  its  transmitter  turned  off.  Both  radios  are  continually  monitored  for correct operation and alarms are raised if an event occurs.  Both the active and standby radios send regular ‘keep alive’ messages to each other to indicate if they are operating correctly. In the event of a failure on the active radio, the RF link and user interface traffic is automatically switched to the standby radio. The failed radio can then be replaced in the field without interrupting user traffic.
 Product Options  |  27  Aprisa SR+ Product Description  Duplexer Kits The Aprisa SR+ product range contains Duplexer Kit accessories for use with the Dual Antenna port Aprisa SR+ radios.  UHF Duplexer Kits The Aprisa SR+ UHF Duplexer Kit contains:  1x 1U 19" rack mount shelf with duplexer mounting brackets and screws  1x Duplexer  2x TNC to SMA right angle 590mm cables    Part Number Part Number APSB-KDUP-300-A1 4RF SR+ Acc, Kit, Duplexer, 320-400 MHz, s 5 MHz, p 0.5 MHz, ext APSB-KDUP-400-B1 4RF SR+ Acc, Kit, Duplexer, 400-470 MHz, s 5 MHz, p 0.5 MHz, ext APSB-KDUP-450-M0 4RF SR+ Acc, Kit, Duplexer, 450-520 MHz, s 5 MHz, p 0.5 MHz, ext APSB-KDUP-900-G2 4RF SR+ Acc, Kit, Duplexer, 928-960 MHz, s 9 MHz, p 1 MHz, ext APSB-KDUP-900-G4 4RF SR+ Acc, Kit, Duplexer, 928-960 MHz, s 3.6 MHz, p 0.5 MHz, ext
28  |  Product Options   Aprisa SR+ Product Description  VHF Duplexer Kits The Aprisa SR+ VHF Duplexer Kit contains:  1x 1U 19" rack mount shelf with duplexer mounting brackets and screws  1xVHF Procom Duplexer  1x VHF Filter, Procom BPF 2/3 HX-150, 145 to 174 MHz  1x N type male to N type male 325mm  2x TNC to N type male right angle 590mm cable    Part Number Part Number APSB-KDUP-VHF-R2 4RF SR+ Acc, Kit, Duplexer, 152-175 MHz, s4-6 MHz, p100 kHz, High APSB-KDUP-VHF-R3 4RF SR+ Acc, Kit, Duplexer, 152-175 MHz, s6-8 MHz, p100 kHz, High APSB-KDUP-VHF-R4 4RF SR+ Acc, Kit, Duplexer, 152-175 MHz, s8-10 MHz, p100 kHz, High APSB-KDUP-VHF-R5 4RF SR+ Acc, Kit, Duplexer, 138-156 MHz, s4-6 MHz, p100 kHz, Low APSB-KDUP-VHF-R6 4RF SR+ Acc, Kit, Duplexer, 138-156 MHz, s6-8 MHz, p100 kHz, Low APSB-KDUP-VHF-R7 4RF SR+ Acc, Kit, Duplexer, 138-156 MHz, s8-10 MHz, p100 kHz, Low
 Product Options  |  29  Aprisa SR+ Product Description  USB RS-232 Serial Port The  Aprisa  SR+  USB  host  port  is  predominantly  used  for  software  upgrade  and  diagnostic  reporting. However, it can also be used to provide an additional RS-232 DCE serial port for customer traffic. This is accomplished with a USB to RS-232 serial converter cable. This plugs into the USB host port   connector and can be terminated with the required customer connector. This additional RS-232 serial port is enabled with the SuperVisor mode setting in Serial Port Settings. The Aprisa  SR+ USB  port  has driver support  for these  USB serial  converters.  Other USB  serial converters may not operate correctly.  USB RS-232 operation The USB serial converter buffers the received data frames into 64 byte blocks separated by a small inter-frame gap. For the majority of applications, this fragmentation  of egress frames is not an issue. However, there are some  applications  that  may  be  sensitive  to  the  inter-frame  gap,  therefore,  these  applications  need consideration. A 5 ms inter-frame is recommended for the applications that are sensitive to inter-frame gap timings.    On a USB RS-232 port, Modbus RTU can operate up to 9600 bit/s with all packet sizes and up to 115200 bit/s if the packet size is less than 64 bytes. The standard RS-232 port is fully compatible with Modbus RTU at all baud rates.
30  |  Specifications   Aprisa SR+ Product Description  3. Specifications RF Specifications  Blocking (desensitization), intermodulation, spurious response rejection, and adjacent channel selectivity values determined according to the methods introduced in V1.7.1 of ETSI standards EN 300 113-1.  Frequency Bands  ETSI Compliant Broadcast Band Frequency Band Frequency Tuning Range Synthesizer Step Size UHF 320 MHz 320-400 MHz 6.250 kHz  ETSI / FCC / IC Compliant Broadcast Band Frequency Band Frequency Tuning Range Synthesizer Step Size VHF 135 MHz (1) 135-175 MHz 2.5 kHz UHF 400 MHz 400-470 MHz 6.250 kHz  ETSI / FCC Compliant Broadcast Band Frequency Band Frequency Tuning Range Synthesizer Step Size UHF 450 MHz (1) 450-520 MHz 6.250 kHz  FCC / IC Compliant Broadcast Band Frequency Band Frequency Tuning Range Synthesizer Step Size (1)(1)UHF 896 MHz (1) 896-902 MHz 6.250 kHz UHF 928 MHz (1) 928-960 MHz 6.250 kHz   Note 1: Please consult 4RF for availability.  UHF 220 MHz   220-222 MHz 2.5 kHz UHF 220 MHz   216-220 MHz 3.125 kHz
 Specifications  |  31  Aprisa SR+ Product Description  Channel Sizes ETSI Compliant  135 / 320 / 400 / 450 MHz Bands No Forward Error Correction Channel Size Gross Radio Capacity  64 QAM 16 QAM QPSK 4-CPFSK 12.5 kHz 60.0 kbit/s 40.0 kbit/s 20.0 kbit/s 9.6 kbit/s 25 kHz 120.0 kbit/s 80.0 kbit/s 40.0 kbit/s 19.2 kbit/s  Minimum Coded Forward Error Correction Channel Size Gross Radio Capacity less FEC  64 QAM 16 QAM QPSK 4-CPFSK 12.5 kHz 52.0 kbit/s 23.1 kbit/s 11.6 kbit/s 8.4 kbit/s 25 kHz 103.9 kbit/s 46.2 kbit/s 23.1 kbit/s 16.7 kbit/s  Maximum Coded Forward Error Correction Channel Size Gross Radio Capacity less FEC  64 QAM 16 QAM QPSK 4-CPFSK 12.5 kHz 45.6 kbit/s 17.3 kbit/s 8.7 kbit/s 4.1 kbit/s 25 kHz 91.2 kbit/s 34.6 kbit/s 17.3 kbit/s 8.3 kbit/s
32  |  Specifications   Aprisa SR+ Product Description  FCC / IC Compliant 135 / 400 / 450 MHz Bands No Forward Error Correction Channel Size Gross Radio Capacity  64 QAM 16 QAM QPSK 4-CPFSK 12.5 kHz 54.0 kbit/s 36.0 kbit/s 18.0 kbit/s 9.6 kbit/s 25 kHz 96.0 kbit/s 64.0 kbit/s 32.0 kbit/s 19.2 kbit/s  Minimum Coded Forward Error Correction Channel Size Gross Radio Capacity less FEC  64 QAM 16 QAM QPSK 4-CPFSK 12.5 kHz 46.8 kbit/s 20.8 kbit/s 10.4 kbit/s 8.4 kbit/s 25 kHz 83.1 kbit/s 37.0 kbit/s 18.5 kbit/s 16.7 kbit/s  Maximum Coded Forward Error Correction Channel Size Gross Radio Capacity less FEC  64 QAM 16 QAM QPSK 4-CPFSK 12.5 kHz 41.0 kbit/s 15.6 kbit/s 7.8 kbit/s 4.1 kbit/s 25 kHz 73.0 kbit/s 27.7 kbit/s 13.9 kbit/s 8.3 kbit/s
 Specifications  |  33  Aprisa SR+ Product Description  220 / 896 / 928 MHz Bands No Forward Error Correction Channel Size Gross Radio Capacity  64 QAM 16 QAM QPSK 4-CPFSK 12.5 kHz 60.0 kbit/s 40.0 kbit/s 20.0 kbit/s 9.6 kbit/s 25 kHz 96.0 kbit/s 64.0 kbit/s 32.0 kbit/s 19.2 kbit/s 50 kHz 216.0 kbit/s 144.0 kbit/s 72.0 kbit/s 38.4 kbit/s  Minimum Coded Forward Error Correction Channel Size Gross Radio Capacity less FEC  64 QAM 16 QAM QPSK 4-CPFSK 12.5 kHz 52.0 kbit/s 23.1 kbit/s 11.6 kbit/s 8.4 kbit/s 25 kHz 83.1 kbit/s 37.0 kbit/s 18.5 kbit/s 16.7 kbit/s 50 kHz 187.1 kbit/s 83.2 kbit/s 41.6 kbit/s 33.4 kbit/s  Maximum Coded Forward Error Correction Channel Size Gross Radio Capacity less FEC  64 QAM 16 QAM QPSK 4-CPFSK 12.5 kHz 45.6 kbit/s 17.3 kbit/s 8.7 kbit/s 4.1 kbit/s 25 kHz 73.0 kbit/s 27.7 kbit/s 13.9 kbit/s 8.3 kbit/s 50 kHz 164.2 kbit/s 62.4 kbit/s 31.2 kbit/s 16.5 kbit/s
34  |  Specifications   Aprisa SR+ Product Description  Receiver ETSI / FCC / IC Compliant Receiver Sensitivity   12.5 kHz 25 kHz 50 kHz FCC / IC only BER < 10-2 64 QAM Max coded FEC -106 dBm -102 dBm -99 dBm BER < 10-2 64 QAM Min coded FEC -105 dBm -101 dBm -98 dBm BER < 10-2 64 QAM No FEC -103 dBm -99 dBm -96 dBm BER < 10-2 16 QAM Max coded FEC -113 dBm -110 dBm -107 dBm BER < 10-2 16 QAM Min coded FEC -112 dBm -109 dBm -106 dBm BER < 10-2 16 QAM No FEC -109 dBm -106 dBm -103 dBm BER < 10-2 QPSK Max coded FEC -118 dBm -115 dBm -112 dBm BER < 10-2 QPSK Min coded FEC -117 dBm -114 dBm -111 dBm BER < 10-2 QPSK No FEC -115 dBm -112 dBm -109 dBm BER < 10-2 4-CPFSK Max coded FEC NA NA NA BER < 10-2 4-CPFSK Min coded FEC -117 dBm -114 dBm -111 dBm BER < 10-2 4-CPFSK No FEC -115 dBm -112 dBm -109 dBm BER < 10-6 64 QAM Max coded FEC -103 dBm -99 dBm -96 dBm BER < 10-6 64 QAM Min coded FEC -101 dBm -97 dBm -94 dBm BER < 10-6 64 QAM No FEC -96 dBm -92 dBm -89 dBm BER < 10-6 16 QAM Max coded FEC -110 dBm -107 dBm -104 dBm BER < 10-6 16 QAM Min coded FEC -108 dBm -105 dBm -102 dBm BER < 10-6 16 QAM No FEC -102 dBm -99 dBm -96 dBm BER < 10-6 QPSK Max coded FEC -115 dBm -112 dBm -109 dBm BER < 10-6 QPSK Min coded FEC -113 dBm -110 dBm -107 dBm BER < 10-6 QPSK No FEC -108 dBm -105 dBm -102 dBm BER < 10-6 4-CPFSK Max coded FEC NA NA NA BER < 10-6 4-CPFSK Min coded FEC -113 dBm -110 dBm -107 dBm BER < 10-6 4-CPFSK No FEC -108 dBm -105 dBm -102 dBm
 Specifications  |  35  Aprisa SR+ Product Description  ETSI / FCC / IC Compliant Adjacent Channel Selectivity   12.5 kHz 25 kHz 50 kHz FCC / IC only Adjacent channel selectivity > -47 dBm > -37 dBm > -37 dBm BER < 10-2 64 QAM > 43 dB > 53 dB > 53 dB BER < 10-2 16 QAM > 43 dB > 53 dB > 53 dB BER < 10-2 QPFK > 48 dB > 58 dB > 58 dB BER < 10-2 4-CPFSK > 55 dB > 65 dB > 65 dB  ETSI / FCC / IC Compliant Co-Channel Rejection   12.5 kHz 25 kHz 50 kHz FCC / IC only BER < 10-2 64 QAM > –23 dB > –23 dB > –23 dB BER < 10-2 16 QAM > –19 dB > –19 dB > –19 dB BER < 10-2 QPFK > –12 dB > –12 dB > –12 dB BER < 10-2 4-CPFSK > –17 dB > –17 dB > –17 dB  ETSI / FCC / IC Compliant Intermodulation Response Rejection   12.5 kHz 25 kHz 50 kHz FCC / IC only Intermodulation response rejection > -35 dBm > -35 dBm > -35 dBm BER < 10-2 64 QAM > 55 dB > 55 dB > 55 dB BER < 10-2 16 QAM > 55 dB > 55 dB > 55 dB BER < 10-2 QPFK > 60 dB > 60 dB > 60 dB BER < 10-2 4-CPFSK > 65 dB > 65 dB > 65 dB  ETSI / FCC / IC Compliant Blocking or Desensitization   12.5 kHz 25 kHz 50 kHz FCC / IC only Blocking or desensitization > -17 dBm > -17 dBm > -17 dBm BER < 10-2 64 QAM > 73 dB > 73 dB > 73 dB BER < 10-2 16 QAM > 73 dB > 73 dB > 73 dB BER < 10-2 QPFK > 78 dB > 78 dB > 78 dB BER < 10-2 4-CPFSK > 85 dB > 85 dB > 85 dB
36  |  Specifications   Aprisa SR+ Product Description  ETSI / FCC / IC Compliant Spurious Response Rejection   12.5 kHz 25 kHz 50 kHz FCC / IC only Spurious response rejection > -32 dBm > -32 dBm > -32 dBm BER < 10-2 64 QAM > 58 dB > 58 dB > 58 dB BER < 10-2 16 QAM > 58 dB > 58 dB > 58 dB BER < 10-2 QPFK > 63 dB > 63 dB > 63 dB BER < 10-2 4-CPFSK > 70 dB > 70 dB > 70 dB  ETSI / FCC / IC Compliant Receiver Spurious Radiation   12.5 kHz 25 kHz 50 kHz FCC / IC only Receiver spurious radiation > -57 dBm > -57 dBm > -57 dBm
 Specifications  |  37  Aprisa SR+ Product Description  Transmitter  Average Power output 64 QAM 0.01 to 2.5 W (+10 to +34 dBm, in 1 dB steps) Note: The Peak Envelope Power (PEP) at maximum set power level is +41 dBm. 16 QAM 0.01 to 3.2 W (+10 to +35 dBm, in 1 dB steps) QPSK 0.01 to 5.0 W (+10 to +37 dBm, in 1 dB steps) 4-CPFSK (Note 1) 0.01 to 10.0 W (+10 to +40 dBm, in 1 dB steps)  Note 1: Please consult 4RF for availability  Note:  The  Aprisa  SR+  transmitter  contains  power  amplifier  protection  which  allows  the  antenna  to  be disconnected from the antenna port without product damage.   Adjacent channel power < - 60 dBc Transient adjacent channel power < - 60 dBc Spurious emissions < - 37 dBm Attack time < 1.5 ms Release time < 0.5 ms Data turnaround time < 2 ms Frequency stability ± 1.0 ppm  ± 0.1 ppm The 220 / 896 / 928 MHz products have a frequency stability option of ± 0.1 ppm. Frequency aging < 1 ppm / annum  Modem  Forward Error Correction Variable length concatenated Reed Solomon plus convolutional code Adaptive Burst Support Adaptive FEC Adaptive Coding Modulation  Data Payload Security  Data payload security CCM*  Counter with CBC-MAC Data encryption Counter Mode Encryption (CTR) using Advanced Encryption Standard (AES) 128, 192 or 256 Data authentication Cipher Block Chaining Message Authentication Code (CBC-MAC) using Advanced Encryption Standard (AES) 128, 192 or 256
38  |  Specifications   Aprisa SR+ Product Description  Interface Specifications  Ethernet Interface  The Aprisa SR+ radio features an integrated 10Base-T/100Base-TX layer-2 Ethernet switch. To simplify network setup, each port supports auto-negotiation and auto-sensing MDI/MDIX. Operators can select from the following preset modes:  Auto negotiate  10Base-T half or full duplex  100Base-TX half or full duplex The Ethernet ports are IEEE 802.3-compatible. The L2 Bridge (Switch) is IEEE 802.1d/q/p compatible, and supports VLANs and VLAN manipulation of add/remove VLANs.  General Interface RJ45 x 2 (Integrated 2-port switch)  Cabling CAT-5/6 UTP, supports auto MDIX (Standard Ethernet)  Maximum line length 100 metres on cat-5 or better  Bandwidth allocation The Ethernet capacity maximum is determined by the available radio link capacity.  Maximum transmission unit Option setting of 1522 or 1536 octets  Address table size 1024 MAC addresses  Ethernet mode 10Base-T or 100Base-TX  Full duplex or half duplex  (Auto-negotiating and auto-sensing) Diagnostics Left Green LED Off: no Ethernet signal received On: Ethernet signal received  Right Orange LED Off: no data present on the interface Flashing: data present on the interface  Note: Do not connect Power over Ethernet (PoE) connections to the Aprisa SR+ Ethernet ports as this will damage the port.
 Specifications  |  39  Aprisa SR+ Product Description  RS-232 Asynchronous Interface  The Aprisa SR+ radio’s ITU-T V.24 compliant  RS-232 interface is configured as  a Cisco® pinout  DCE. The interface  terminates  to  a  DTE  using  a  straight-through  cable  or  to  a  DCE  with  a  crossover  cable  (null modem). The interface uses two handshaking control lines between the DTE and the DCE.  General Interface ITU-T V.24 / EIA/TIA RS-232E  Interface direction DCE only  Maximum line length 10 metres (dependent on baud rate) Async parameters Standard mode data bits 7 or 8 bits  Standard mode parity Configurable for None, Even or Odd  Standard mode stop bits 1 or 2 bits  Interface baud rates 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200 bit/s Control signals DCE to DTE CTS, RTS, DSR, DTR Diagnostics Left Green LED Off: no RS-232 device connected On: RS-232 device connected  Right Orange LED Off: no data present on the interface Flashing: data present on the interface
40  |  Specifications   Aprisa SR+ Product Description  Hardware Alarms Interface  The hardware alarms interface supports two alarm inputs and two alarms outputs.  Alarm Inputs The alarm connector provides two hardware alarm inputs for alarm transmission to the other radios in the network.  Interface RJ45 connector Detector type Non-isolated ground referenced voltage detector Detection voltage - on > +10 VDC Detection voltage - off < +4 VDC Maximum applied input voltage 30 VDC Maximum input current limit 10 mA  Alarm Outputs The alarm connector provides two  hardware alarm outputs  for alarm reception from other radios in the network.  Interface RJ45 connector Output type Non-isolated ground referenced open collector output Maximum applied voltage 30 VDC Maximum drive current 100 mA Overload protection Thermally resettable fuse  Protect Interface The Protect interface is used to connect the radios to the protection switch within a Protected Station. It is not a customer interface.  Interface Female protect connector  Protection Switch Specifications  RF Insertion Loss < 0.5 dB Remote Control inputs Logic 4700 ohms pullup to +3.3 VDC
 Specifications  |  41  Aprisa SR+ Product Description  Power Specifications  Power Supply Aprisa SR+ Radio  Nominal voltage +13.8 VDC  (negative earth) Absolute input voltage range +10 to +30 VDC Maximum power input 35 W Connector Molex 2 pin male screw fitting 39526-4002  Aprisa SR+ Protected Station  Nominal voltage +13.8 VDC  (negative earth) Absolute input voltage range +10 to +30 VDC Maximum power input 35 W Connector 2x Molex 2 pin male screw fitting 39526-4002  Aprisa SR+ Data Driven Protected Station  Nominal voltage +13.8 VDC  (negative earth) Absolute input voltage range +10 to +30 VDC Maximum power input 35 W Connector 2x Molex 2 pin male screw fitting 39526-4002
42  |  Specifications   Aprisa SR+ Product Description  Power Consumption Note:  The  radio  power  consumption  is  very  dependent  on  transmitter  power,  the  type  of  traffic  and network activity.  Aprisa SR+ Radio  Mode Power Consumption (10 W radio with 4-CPFSK modulation) Transmit / Receive < 35 W for 10 W transmit power  < 25.0 W for 1 W transmit power Receive only < 7 W  Aprisa SR+ Protected Station and Aprisa SR+ Data Driven Protected Station  Mode Power Consumption (10 W radios with 4-CPFSK modulation) Transmit / Receive < 42 W for 10 W transmit power  < 32.0 W for 1 W transmit power Receive only < 15 W   Power Dissipation Aprisa SR+ Radio  Transmit Power Power Dissipation (10 W radio with 4-CPFSK modulation) 10 W transmit power < 25 W 1 W transmit power < 24 W  Aprisa SR+ Protected Station and Aprisa SR+ Data Driven Protected Station  Transmit Power Power Dissipation (10 W radios with 4-CPFSK modulation) 10 W transmit power < 32 W 1 W transmit power < 31 W
 Specifications  |  43  Aprisa SR+ Product Description  General Specifications  Environmental  Operating temperature range -40 to +70˚ C (-40 to +158˚ F) Storage temperature range -40 to +80˚ C (-40 to +176˚ F) Operating humidity Maximum 95% non-condensing Acoustic noise emission No audible noise emission  Mechanical  Aprisa SR+ Radio  Dimensions Width  210 mm (8.27”) Depth  130 mm (5.12”) and 146 mm (5.748”) with TNC connectors Height  41.5 mm (1.63”) Weight 1.25 kg (2.81 lbs) Colour Matt black Mounting Wall (2 x M5 screws) Rack shelf (2 x M4 screws) DIN rail bracket  Aprisa SR+ Protected Station  Dimensions Width  432.6 mm (17”) Depth  372 mm (14.6”) and 388 mm (15.276”) with TNC connectors Height  2U plus external duplexer (if used) Weight 12 kg (27 lbs) (includes the 2 radios)  Colour Matt black Mounting Rack mount (2 x M6 screws)
44  |  Specifications   Aprisa SR+ Product Description  Compliance  ETSI Radio EN 300 113-2 EMI / EMC EN 301 489 Parts 1 & 5 Safety EN 60950-1:2006 Class 1 div 2 for hazardous locations Environmental ETS 300 019 Class 3.4 Ingress Protection code IP51  FCC Radio  47CFR part 24, part 90 and part 101 Private Land Mobile Radio Services EMC 47CFR part 15 Radio Frequency Devices, EN 301 489 Parts 1 & 4 Safety EN 60950-1:2006 Class 1 div 2 for hazardous locations Environmental ETS 300 019 Class 3.4 Ingress Protection code IP51  IC Radio RSS-119 / RSS-134 EMC This Class A digital apparatus complies with Canadian standard ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Safety EN 60950-1:2006 Class 1 div 2 for hazardous locations Environmental ETS 300 019 Class 3.4 Ingress Protection code IP51
 Management  |  45  Aprisa SR+ Product Description  4. Management SuperVisor  The Aprisa SR+ contains an embedded web server application (SuperVisor) to enable element management with any major web browser (such as Mozilla Firefox or Microsoft® Internet Explorer). SuperVisor  enables operators  to  configure  and manage the  Aprisa  SR+  base station  radio and  repeater / remote station radios over the radio link.  The key features of SuperVisor are:  Full element management, configuration and diagnostics  Manage the entire network from the Base Station (remote management of elements)  Managed network software distribution and upgrades  Performance  and  alarm  monitoring  of  the  entire  network,  including  RSSI,  alarm  states,  time-stamped events.  View  and  set  standard  radio  configuration  parameters  including  frequencies,  transmit  power, channel access, serial, Ethernet port settings  Set and view security parameters  User management  Operates over a secure HTTPS session on the access connection to the base station  The following are three examples of SuperVisor screens:
46  |  Management   Aprisa SR+ Product Description  Viewing the Aprisa SR+ Terminal Settings  The SuperVisor software enables operators to view the terminal settings:
 Management  |  47  Aprisa SR+ Product Description  Configuring the Aprisa SR+ Terminal Details  The SuperVisor software enables operators to set the terminal details including Terminal Name, Location, Contact Name and Contact Details with a maximum of 40 characters.    Configuring the Aprisa SR+ RF Network Details  The SuperVisor software enables operators to set the RF Network Details including:  Network ID Sets the network ID of this base station node and its remote nodes. Four hex chars Network Radius Sets the maximum number of hops in this network Network Repeaters Proximity Sets the proximity of repeaters in this network Inband Management Enables inband management of remotes / repeaters Inband Management Timeout (sec) Sets the inband management timeout period
48  |  Management   Aprisa SR+ Product Description  Configuring the Aprisa SR+ Radio Settings    The SuperVisor software enables operators to set the radio settings including:  TX Frequency Sets the transmit frequency in MHz TX Power Sets the transmit Power in dBm RX Frequency Sets the receive frequency in MHz Channel Size Sets the channel size 12.5 kHz, 25 kHz or 50 kHz (depending on variant) Antenna Port Configuration Sets the antenna port configuration to single port or dual port Modulation Type Sets the fixed TX Modulation Type for the base station radio ACM Control Enables / disables Adaptive Code Modulation for the remote to base direction of transmission (upstream) Modulation Range Sets the upper limit of the range that the base station willl recommmend to the remote radios
 Management  |  49  Aprisa SR+ Product Description  Command Line Interface  The Aprisa SR+ has a Command Line Interface (CLI) which provides basic product setup and configuration. This interface can be accessed via an Ethernet Port (RJ45) or the Management Port (USB micro type B). The Terminal menu is shown in the following picture:    SNMP  In  addition  to  web-based  management  (SuperVisor)  and  the  Command  Line  Interface,  the  Aprisa  SR network can also be managed using the Simple Network Management Protocol (SNMP agent). MIB files are supplied  which  can  be  used  by  a  dedicated  SNMP  Manager,  such  as  Castle  Rock’s network  management system, to support effective and flexible network monitoring and diagnostics.  Alternatively, the user can use its own 3rd party NMS SNMP agent to manage the SR+ radio network. For  communication  between  the  SNMP  manager  and  the  radio,  Access  Controls  and  Community  strings must be set up as described in the Aprisa SR+ User Manual.
50  |  Management   Aprisa SR+ Product Description  LED Display Panel  The Aprisa SR+ has an LED Display panel which provides on-site alarms / diagnostics without the need for PC.      Normal Operation In normal radio operation, the LEDs indicate the following conditions:   OK MODE AUX TX RX Solid Red Alarm present with severity Critical, Major and Minor   TX path fail RX path fail Flashing Red    Radio not connected to a base station Radio not connected to a base station Solid Orange Alarm present with Warning Severity Stand-by radio in protected station Device detect on the USB host port (single flash)   Flashing Orange  Diagnostics Function Active  OTA Firmware Distribution Tx Data or Rx Data on the USB management or host port    Flashing Green    RF path TX is active RF path RX is active Solid Green Power on and functions OK and no alarms Processor Block is OK or active radio in protected station USB interface OK Tx path OK Rx path OK   LED Colour Severity Green No alarm – information only Orange Warning alarm Red Critical, major or minor alarm
 Management  |  51  Aprisa SR+ Product Description  Single Radio Software Upgrade During a radio software upgrade, the LEDs indicate the following conditions:  Software upgrade started - the OK LED flashes orange  Software upgrade progress indicated by running RX to OK LEDs  Software upgrade completed successfully - the OK LED solid orange  Software upgrade failed - any LED flashing red during the upgrade  Network Software Upgrade During  a  network  software  upgrade,  the  MODE  LED  flashes  orange  on  the  base  station  and  all  remote stations.  Test Mode In Test Mode, the LED Display panel  presents a real  time  visual display of the RSSI. This can be used to adjust the antenna for optimum signal strength.
52  |  Applications   Aprisa SR+ Product Description  5. Applications This section describes sample Aprisa SR+ radio applications. The following applications are described:  Basic point-to-multipoint application  Advanced point-to-multipoint application with repeaters  Multi-interface point-to-multipoint application  Multi-hop Daisy chain repeaters in LBS mode application  Pseudo Peer to Peer using base-repeater application  Basic point-to-multipoint application  Single base station with Ethernet SCADA data inputs to multiple geographically remote sites with Ethernet RTUs requiring control and data acquisition. The base station receives Ethernet frames from the SCADA server LAN and broadcasts all Ethernet frames to all remote stations  Each remote site receives Ethernet frames from the RTU and unicasts over the air to the base station. The base station uses an omni directional antenna to provide wide coverage and the remote stations are fitted with directional Yagi antennas to provide higher gain.
 Applications  |  53  Aprisa SR+ Product Description  Advanced point-to-multipoint application with repeater  Single base station with Ethernet SCADA data inputs to multiple geographically remote sites with Ethernet RTUs  requiring  control  and  data  acquisition.  A  repeater  is  deployed  to  service  remote  sites  beyond  the reach of the base station. The base station receives Ethernet frames from the SCADA server LAN and broadcasts all Ethernet frames to the repeater and its remote stations.  Three remote sites have direct radio communication with the base station but the other two remote sites operate via the repeater site. Each remote site receives Ethernet frames from the RTU and unicasts over the air to the repeater / base station. The base station and the repeater station use an omni directional antenna to provide wide coverage and the remote stations are fitted with directional Yagi antennas to provide higher gain.
54  |  Applications   Aprisa SR+ Product Description  Multi-interface point-to-multipoint application  Single base  station with  Ethernet and RS-232  SCADA  data  inputs to  multiple  geographically  remote sites with Ethernet and RS-232 RTUs requiring control and data acquisition. The base station receives Ethernet / RS-232 frames from the SCADA servers and broadcasts all frames to all remote stations  Each remote site receives Ethernet / RS-232 frames from  the RTU and unicasts over the air to the base station. The base station uses an omni directional antenna to provide wide coverage and the remote stations are fitted with directional Yagi antennas to provide higher gain.
 Applications  |  55  Aprisa SR+ Product Description  Multi-hop Daisy Chain Repeaters in LBS Mode Application This  application  is  used  for  daisy  chain  repeaters  when  remote  stations  are  very  far  from  base  station coverage. Daisy  chain repeaters  can  only be used in LBS channel access  mode (and future release in AR mode).  In the figure example below, the Base Station can communicate with any of the far remotes via the daisy chain repeaters. The SCADA master will communicate with RTU 2 using a source and destination IP address and the underlining SCADA protocol. On  the  downstream,  the  SCADA  master  would  like  to  communicate  with  RTU-2  and  sends  a  packet destined to RTU-2  (using RTU 2 destination address). This packet received  by the Base Station will then broadcast OTA to Repeater 1. Repeater 1 will store-and-forward the received packet and re-transmit the packet to Repeater 2 and back to the Base Station, which will drop the duplicate packet as this packet is its own forward. Repeater  2  will  store-and-forward  the  packet  to  the  local  Ethernet  port  to  RTU  3  (which  will  drop  the packet due to destination  address  mismatch)  and it will also re-transmit the  packet OTA to Repeater  3, Remote 1 and back to Repeater 1, which will drop the duplicate packet as this packet is its own forward. Remote-1  will  forward  the  packet  to  its  local  Ethernet  port  and  RTU-1  will  drop  the  packet  due  to destination address mismatch. Repeater 3 will store-and-forward and re-transmit the packet OTA to Remote-2 and back to Repeater 2, which will drop the packet as duplicate packet as this packet is its own forward.  Remote 2 will then forward the packet to its local Ethernet port and RTU 2 as the destined address which will process the packet accordingly. On the upstream, RTU 2 will send a packet to the SCADA master, and the radio network from Remote 2 sending  a  unicast  packet  destined  to  Base  Station  which  will  act  with  the  same  process  mechanism  as described above for downstream path.
56  |  Applications   Aprisa SR+ Product Description  Pseudo Peer to Peer using Base-Repeater Application This  application  is  used  for  remote  peer  to  peer  communication  via  a  base-repeater  or  repeater configuration.  In  peer  to  peer,  the  source  RTU  will  create  a  message  with  destination  address  of  the destined RTU in the SCADA layer protocol (and/or IP layer, if applicable). Note, this address is only known by the RTUs as the SR+ radio is transparent to SCADA protocol messages. Although all messages sent from remotes are always destined to the base station, packets can be sent from one remote to the other using the ‘packet  filtering’ peer to  peer  feature (see  the  Aprisa  SR+ User  Manual  Radio  >  Channel Setup) and base-repeater or repeater configuration. In  the  figure  example  below,  RTU  1  would  like  to  communicate  with  RTU  3,  and  thus,  Remote  1  and Remote 3 will be configured with ‘packet filtering’ set to ‘disabled’ and the Base station configured as a Base-repeater.  RTU 1 will create a message destined to RTU 3 and forward it to Remote 1, which in turn will forward it as a unicast message OTA to the Repeater Station, destined to the Base Station (all packets from a remote are destined to the base station).  The  Repeater  Station  will  store-and-forward  the  message  received  from  Remote  1  and  re-transmit  the message to Base Station, but it will also be received by Remote 2. Since, Remote 2 is not the destination and packet filtering is set to automatic (enabled), the packet will be dropped by Remote 2. Note, Remote 3 and Remote 4 can’t hear the Repeater Station. The Base-Repeater  will forward  the packet  to  the local  ports  (Ethernet  and/or  serial), and  will also re-transmit the packet OTA to Remote 3 and Remote 4 and back to the Repeater (this is specific and default to  Base-Repeater functionality, as  packet filtering  is  not  used in  Base-Repeater operation  and it  can  be left in default (automatic)). The Repeater will drop the duplicate packet as this packet is its own forward. Remote 3 will receive the packet and forward it to it local ports (Ethernet or Serial) and to its local RTU 3, as packet filtering is disabled which will then process the packet accordingly. Remote 4 will also receive the  packet,  but  it  will  drop  the  packet  as  packet  filtering  is  enabled.  If  Remote  4  had  packet  filtering disabled, the packet would be forwarded to the local port and dropped by RTU 4, due to SCADA protocol destination address mismatch (and/or IP destination address mismatch, if applicable).
 Product Architecture  |  57  Aprisa SR+ Product Description  6. Product Architecture Product Operation There are three components to the wireless interface: the Physical Layer (PHY), the Data Link Layer (DLL) and the Network Layer. These three layers are required to transport data across the wireless channel in the Point-to-multipoint (PMP) configuration. The Aprisa SR+ DLL is largely based on the 802.15.4 MAC layer using a proprietary implementation.  Physical Layer The Aprisa SR+ PHY uses a one or two frequency half duplex transmission mode which eliminates the need for  a  duplexer.  However,  a  Dual  Antenna  port  option  is  available  for  separate  transmit  and  receive antenna connection to support external duplexers or filters (half duplex operation). Remote nodes are predominantly in receive mode with only sporadic bursts of transmit data. This reduces power consumption. The  Aprisa  SR+  is  a  packet  based  radio.  Data  is  sent  over  the  wireless  channel  in  discrete  packets  / frames, separated in time. The PHY demodulates data within these packets with coherent detection. The Aprisa SR+ PHY provides carrier, symbol and frame synchronization predominantly through the use of preambles.  This  preamble  prefixes  all  packets  sent  over  the  wireless  channel  which  enables  fast Synchronization.  Data Link Layer / MAC layer The Aprisa SR+ PHY enables multiple users to be able to share a single wireless channel; however a DLL is required to manage  data transport. The  two key components  to  the DLL are  channel access  and  hop  by hop transmission.  Channel Access The Aprisa SR+ radio has two modes of channel access, Access Request and Listen Before Send.  Option Function Access Request Channel access scheme where the base stations controls the communication on the channel.  Remotes ask for access to the channel, and the base station grants access if the channel is not occupied. Listen Before Send Channel access scheme where network elements listen to ensure the channel is clear, before trying to access the channel.
58  |  Product Architecture   Aprisa SR+ Product Description  Access Request This scheme is particularly suited to digital SCADA systems where all data flows through the base station.  In  this  case  it  is  important  that  the  base  station  has  contention-free  access  as  it  is  involved  in  every transaction.    The  channel  access  scheme  assigns  the  base  station  as  the  channel  access  arbitrator  and therefore inherently it has contention-free access to the channel.  This means that there is no possibility of contention on data originating from the base station.  As all data flows to or from the base station, this significantly improves the robustness of the system. All  data  messages  are  controlled  via  the  AG  (access  grant)  control  message  and  therefore  there  is  no possibility of contention on the actual end user data.  If a remote station accesses the channel, the only contention risk is on the AR (access request) control message.  These control messages are designed to be as short as possible and therefore the risk of collision of these control messages is significantly reduced.  Should collisions occur these are resolved using a random back off and retry mechanism. As  the  base  station  controls  all  data  transactions  multiple  applications  can  be  effectively  handled, including a mixture of polling and report by exception.  Listen Before Send The Listen Before Send channel access scheme is realized using Carrier Sense Multiple Access (CSMA). In this mode, a pending transmission requires the channel to be clear. This is determined by monitoring the channel  for  other  signals  for  a  set  time  prior  to  transmission.  This  results  in  reduced  collisions  and improved channel capacity. There are still possibilities  for collisions with this technique e.g. if two  radios simultaneously determine the channel is clear and transmit at the same time. In this case an acknowledged transaction may be used. The transmitter  requests  an  ACK  to  ensure that the transmission has been  successful. If the transmitter does not receive an ACK, then random backoffs are used to reschedule the next transmission.  Hop by Hop Transmission Hop by Hop Transmission is realized in the Aprisa SR+ by adding a MAC address header to the packet. For 802.15.4, there are 2 addresses, the source and destination addresses.
 Product Architecture  |  59  Aprisa SR+ Product Description  Adaptive Coding Modulation  The  Aprisa  SR+  provides  Adaptive  Coding  Modulation  (ACM)  which  maximizes  the  use  of  the  RF  path  to provide the highest radio capacity available. ACM  automatically  adjusts  the modulation coding  and FEC  code rate in  the  remote  to  base  direction  of transmission  over  the  defined  modulation  range  based  on  the  signal  quality  for  each  individual  remote radio. When  the  RF  path  is  healthy  (no  fading),  modulation  coding  is  increased  and  the  FEC  code  rate  is decreased to maximize the data capacity. If  the  RF path quality  degrades,  modulation  coding  is decreased  and  the FEC  code  rate  is increased  for maximum robustness to maintain path connectivity.
60  |  Product Architecture   Aprisa SR+ Product Description  Network Layer  Packet Routing Aprisa SR+ is a standard static IP router which routes and forwards IP packet based on standard IP address and routing table decisions.  Aprisa SR+ router mode (see figure below), enables the routing of IP packets within the Aprisa SR+ wireless network  and  in  and  out  to  the  external  router  /  IP  RTUs  devices  connected  to  the  Aprisa  SR+  wired Ethernet ports. Within the Aprisa SR+ Router mode, each incoming Ethernet packet on the Ethernet port is stripped from its Ethernet header to reveal the IP packet and to  route the IP packet based on its routing table. If  the destination  IP  address  is  one  of  the  RTUs,  the  packet  is  then  forwarded  to  the  wireless  ports  and broadcasted as a PMP wireless packet to all the repeater / remotes stations. The appropriate remote then routes  the  IP  packet  and  forwards  it  based  on  its  routing  table  to  the  appropriate  Ethernet  port, encapsulating  the  appropriate  next  hop  MAC  header  and  forwarding  it  to  the  RTU.  The  RTU  can  then interpret  and  process  the IP data  and communication  is  established  between the  RTU and  the initiating communication device.
 Product Architecture  |  61  Aprisa SR+ Product Description  Static IP Router The  Aprisa  SR+  works  in  the  point-to-multipoint  (PMP)  network  as  a  standard  static  IP  router  with  the Ethernet and wireless / radio as interfaces and serial ports using terminal server as a virtual interface. The  Aprisa  SR+  static  router  is  semi-automated  operation,  where  the  routing  table  is  automatically created in the base station and populated with routes to all remotes and repeater stations in the network during the registration process and vice versa, where the routing table is automatically created in remote and repeater stations and populated with routes to base station during the registration process. Updates occur  when  remote  is  disconnected  from  network  for  any  reason,  with  the  routing  table  updated  in  a controlled fashion. Also,  in  decommission  operation,  the  base  station  routing  tables  are  completely  flushed  allowing  an automatic rebuild. This avoids the user manually inserting / removing of multiple static routes to build / change  the  routes  in  the  network  which  might  be  tedious  and  introduce  significant  human  error.  The Aprisa SR+ works as a static IP router without using any routing protocol and therefore does not have the overhead of a routing protocol for better utilization of the narrow bandwidth network. In addition to the semi-automated routes, the user can manually add / remove routes in the routing table for the radio interface, Ethernet Interface and for routers which are connected to the radio network.  The  Aprisa  SR+  base  station  is  used  as  a  gateway  to  other  networks.  Thus,  a  configurable  IP  address default  gateway  can  be  set  using  a  static  route  in  the  routing  table  with  a  destination  IP  address  of 0.0.0.0. It is used by the router when an IP address does not match any other routes in the routing table. The  Aprisa  SR+  sub-netting  rules  distinguish  between  the  wireless  interface  and  the  remote  Ethernet interface where RTUs are connected. The entire wireless network is set on a single IP subnet, while each Aprisa  SR+  remote’s  Ethernet  interface  is  set  to  a  different  subnet  network.  In  this  way,  the  user  can easily distinguish between the remotes subnet IP addresses.
62  |  Product Architecture   Aprisa SR+ Product Description  Static IP Router – Human Error Free  To ensure correct operation, the Aprisa SR+ router base station alerts when one (or more) of the devices is not configured for router mode or a duplicated IP is detected when manually added.  When  the  user  changes  the  base  station  IP  address  /  subnet,  the  base  station  sends  an  ARP  unsolicited announcement message and the remotes / repeaters auto-update their routing table accordingly. This also allows the router that is connected to the base station to update its next hop IP address and its routing table.  When the user changes the remote / repeater station IP address / subnet, a re-registration process in the base station then auto-updates its routing table accordingly.  Terminal Server - Transition to Converged Ethernet / IP Network  Customers  that  are  transitioning  their  SCADA  network  to  an  Ethernet  /  IP  SCADA  network,  can simultaneously operate their legacy serial RTUs, not as a separate serial network to the new Ethernet / IP network, but as part of the Ethernet / IP network, by using the terminal server feature. The Aprisa SR+ terminal server is an application running in the radio that encapsulates serial traffic into Ethernet  /  IP  traffic.  For  SCADA  networks,  this  enables  the  use  of  both  serial  and  Ethernet  /  IP  RTUs within an Ethernet / IP based SCADA network.
 Product Architecture  |  63  Aprisa SR+ Product Description  Bridge Mode with VLAN Aware  Ethernet VLAN Bridge / Switch Overview The Aprisa SR+ in Bridge  mode of operation is a standard Ethernet Bridge based on IEEE 802.1d or VLAN Bridge based on IEEE 802.1q/p which forward / switch Ethernet packet based on standard MAC addresses and VLANs using FDB (forwarding database) table decisions. VLAN is short for Virtual LAN and is a virtual separate network, within its own broadcast domain, but across the same physical network. VLANs  offer  several  important  benefits  such  as  improved  network  performance,  increased  security  and simplified network management. The  Aprisa  SR+  Bridge  mode  (see  figure  below),  is  the  default  mode  of  operation  and  it  enables  the switching / bridging of Ethernet VLAN tagged or untagged packets within the Aprisa SR+ wireless network and in and out to the external Industrial LAN network and RTUs devices connected to the Aprisa SR+ wired Ethernet ports or serial ports through the terminal server function. Within the Aprisa SR+ Bridge mode, each incoming  Ethernet packet is inspected for the destination MAC address  (and  VLAN)  and  looks  up  its  FDB  table  for  information  on  where  to  send  the  specific  Ethernet frame. If the FDB table doesn’t contain the specific MAC address, it will flood the Ethernet frame out to all ports in the broadcast domain and when using VLAN, the broadcast domain is narrowed to the specific VLAN used in the packet (i.e. broadcast will be done only to the ports which configured with that specific VLAN). The FDB table is used to store the MAC addresses that have been learnt and the ports associated with that MAC  address.  If  the  destination  MAC  address  is  one  of  the  RTUs,  the  packet  is  then  forwarded  to  the wireless  ports  and  broadcast  as  a  PMP  wireless  packet  to  all  the  repeater  /  remote  stations.  The appropriate remote then switches the Ethernet packet and forwards it  based on its FDB table (based on the MAC or VLAN & MAC)  to  the appropriate Ethernet port to the RTU. The RTU  can then interpret and process  the  Ethernet  /  IP  data  and  communication  is  established  between  the  RTU  and  the  initiating communication device.
64  |  Product Architecture   Aprisa SR+ Product Description  VLAN Bridge Mode Description  General – Aprisa SR+ VLAN Bridge Aprisa SR+ works  in the  point-to-multipoint  (PMP)  network as a standard  VLAN bridge with the Ethernet and wireless / radio as interfaces and serial ports using terminal server as a virtual interface. The  Aprisa  SR+  is  a  standard  IEEE  802.1q  VLAN  bridge,  where  the  FDB  table  is  created  by  the  bridge learning / aging process. New MACs are learnt and the FDB table updated. Unused MACs are aged out and flushed automatically after aging period. VLANs are statically configured by the user on the ports where a Virtual LAN is required across the radio network. An example of VLAN isolation of traffic type is shown in the figure below, where RTUs #1, 4 and 6  together  with SCADA  meter master  form  a Virtual  LAN  which  is  isolated from the  other devices,  even though they are on the same physical network. VLAN management can be used to manage with external NMS  all  the  Aprisa  SR+  devices  on  the  radio  network,  and  is  automatically  created  with  a  VLAN  ID  =  1 default value. The VLAN ID can be changed by the user later on. Each device in the Aprisa SR+ bridge is identified by its own IP address, as shown in the figure.
 Product Architecture  |  65  Aprisa SR+ Product Description  VLANs – Single, Double and Trunk VLAN ports The Aprisa SR+ supports single VLAN (CVLAN), double VLAN (SVLAN) and trunk VLAN. A single VLAN can be used to segregate traffic type. A  double  VLAN  can  be  used  to  distinguish  between  Aprisa  SR+  sub-networks  (base-repeater-remote), where the outer SVLAN is used to identify the sub-network and the CVLAN is used to identify the traffic type. In this case, a double tagged VLAN will be forwarded across the Industrial LAN network and switched based  on  the  SVLAN  to  the  appropriate  Aprisa  SR+  sub-network.  When  packet  enters  the  Aprisa  SR+ network, the SVLAN will be stripped off (removed) and the forwarding will be done based on the CVLAN, so  only  a  single  VLAN  will  pass  through  over  the  radio  network  and  double  VLAN  will  be  valid  on  the borders of the radio network. Trunk VLAN is also supported by the Aprisa SR+ where the user can configure multiple VLANs on a specific Ethernet port, creating a trunk VLAN port. For example, in the above figure, a single trunk VLAN port is created between the switch and the Aprisa SR+ base station, carrying VLAN ID #1, 20, 30 and 40.  VLAN Manipulation – Add / Remove VLAN Tags In  order to  support  double  VLAN  and  different  device  types  connected  to  the  Aprisa  SR+  e.g.  switches, RTUs,  etc,  which  can  be  VLAN  tagged  or  untagged  /  plain  Ethernet  devices,  add  /  remove  VLAN manipulation is required.  In  an  Aprisa  SR+  VLAN  tagged  network,  a  remote  Aprisa  SR+  connected  to  a  plain  RTU  without  VLAN support, will remove (strip-off) the VLAN tag from the packet before sending it to the RTU. On the other direction, when the RTU is sending an untagged packet, the Aprisa SR+ will add (append) an appropriate user pre-configure VLAN tag before sending it over the air to the base station. This is shown in the above figure on untagged RTU #5 and 7.  QoS using VLAN VLANs carry 3 priority bits (PCP field) in the VLAN tag allowing prioritization of VLAN tagged traffic types with  8  levels  of  priority  (where  7  is  the  highest  priority  and  0  is  the  lowest  priority).  The  Aprisa  SR+ supports  QoS  (Quality  of  Service)  where  the  priority  bits  in  the  VLAN  tagged  frame  are  evaluated  and mapped to four priority levels and four queues supported by the Aprisa SR+ radio. Packets in the queues are  then  scheduled  out  in  a  strict  priority  fashion  for  transmission  over-the-air  as  per the  priority  level from high to low.
66  |  Product Architecture   Aprisa SR+ Product Description  Avoiding Narrow Band Radio Traffic Overloading  The Aprisa SR+ supports mechanisms to prevent narrowband radio network overload: 1. L3/L4 Filtering The L3 filtering can be used to block undesired traffic from being transferred on the narrow band channel, occupying the channel and risking the SCADA critical traffic. L3/4 filtering has the ability to block a known IP  address  and  applications  using  TCP/IP  or  UDP/IP  protocols  with  multiple filtering  rules.  The  L3  (/L4) filter  can  block/forward  (discard/process)  a  specific  IP  address  and  a  range  of  IP  addresses.  Each  IP addressing filtering rule set can also be set to filter a L4 TCP or UDP port/s which in most cases relates to specific applications as per IANA official and unofficial well-known ports. For example, filter and block E-mail SMTP or TFTP protocol as undesired traffic over the SCADA network. The user can block a specific or range of IP  port  addresses, examples  SMTP (Simple Mail Transfer Protocol) TCP port  25 or TFTP  (Simple Trivial File Transfer Protocol) UDP port 69.  2. L2 Address Filtering L2 Filtering (Bridge Mode) provides the ability to filter radio link traffic based on specified Layer 2 MAC addresses. Destination MAC (DA) addresses and a Source MAC (SA) addresses and protocol type (ARP, VLAN, IPv4, IPv6 or Any type) that meet the filtering criteria will be transmitted over the radio link. Traffic that does not meet the filtering criteria will not be transmitted over the radio link.  3. L2 Port VLANs Ingress Filtering and QoS Double VLAN (Bridge Mode) Double  VLAN  is  used  to  distinguish/segregate  between  different  radio  sub-networks  (Base-repeaters-remotes). Traffic with double VLANs which are not destined to a specific sub-network will be discarded on the ingress of the radio sub-network, avoiding the overload of the radio sub-network. Single VLAN (Bridge Mode) Single  VLAN  is  used  to  distinguish/segregate  between  different  traffic  types  assigned  by  the  user  in  its industrial  corporate LAN.  In order  to avoid the  overload  of the radio  network, traffic  with single  VLANs which are not destined to a specific radio network will be discarded on the  Ethernet ingress port of the radio network. All single VLANs which set and are eligible will be transmitted over the radio link. QoS using 802.1p priority bits (Bridge Mode) The priority bits can be used in the VLAN tagged frames to prioritized critical  mission SCADA traffic and assure SCADA operation related to any other unimportant traffic. In this case, traffic base on VLAN priority (priority 0 to 7) entered to one of the four priority queues of the Aprisa SR/SR+ (Very High, High, Medium and  Low).  Traffic  leaves  the  queues  (to  the  radio  network)  from  highest  priority  to  lowest  in  a  strict priority fashion.   4. Ethernet port QoS  The Aprisa SR+ supports ‘Ethernet Per Port Prioritization’.  Each Ethernet port can be assigned a priority and traffic shall be  prioritized accordingly. This is quite useful in networks  where customers  do  not use VLANs or cannot use 802.1p prioritization.
 Product Architecture  |  67  Aprisa SR+ Product Description  5. Ethernet Data and Management Priority and Background Bulk Data Transfer Rate  Alternatively  to  VLAN  priority,  users  can  control  the  Ethernet  traffic  priority  (vs  serial),  management priority  and  rate  in  order  to  control  the  traffic  load  of  the  radio  network,  where  important  and  high priority data (SCADA) will pass-through first assuring SCADA network operation. The user can set the use of the  Ethernet  Data  Priority,  which  controls  the  priority  of  the  Ethernet  customer  traffic  relative  to  the serial  customer  traffic  and  can  be  set  to  one  of  the  four  queues.  The  Ethernet  Management  Priority controls the priority of the Ethernet management traffic relative to Ethernet customer traffic and can be set to one of the four queues. The Background Bulk Data Transfer Rate sets the data transfer rate (high, medium, low) for large amounts of management data.  6. Ethernet Packet Time to Live  Another aspect of avoiding overload radio network is the Ethernet packet TTL, which is used to prevent old,  redundant  packets  being  transmitted  through  the  radio  network.  This  sets  the  time  an  Ethernet packet is allowed to live in the system before being dropped if it cannot be transmitted over the air.  7. Robust Header Compression (ROHC) and Payload Compression Aprisa SR+ supports ROHC (Robust Header Compression RFC3095). ROHC is a standard way to compress IP, UDP  and  TCP  headers  and  this  significantly  increases  IP  traffic  throughput  especially  in  narrow  band network. Aprisa SR+ supports payload compression. A Lempel–Ziv (LZ) algorithm is used to efficiently compress up to 50%  traffic  with  high  percentage  of  repetitive  strings.  Both  serial  and  Ethernet  /  IP  payload  traffic  are compressed.
68  |  Product Architecture   Aprisa SR+ Product Description  Product Architecture  The following are the key components of the Aprisa SR+ design:  Dual high performance ΣΔ fractional-N synthesizers to allow for full duplex operation   Wideband design electronically tunes over entire band   Proven low noise and spurious technology with over 50dB of SNR easily achieved   Power amplifier linearity  Unique  temperature  compensated  pre-distortion  system  improves  the  efficiency  and  linearity  of the entire transmitter chain for non-constant envelope modulation systems   Simple IQ modulation line up reduces part count and improves MTBF   No mixing stages so no spurious responses present at the transmitter output   Digital  control  loops used  for controlling  power  amplifier  current and transmit  output power, allows for faster ramping and settling times with less error  Tx turn-on time limited primarily by PA ramping   Robust, closed-loop power control – fast, accurate power ramp up and down   Highly rugged N-Channel RF Power LDMOS transistors for the power amplifier   High efficiency (>50% PAE at 10W)   Very low thermal resistance (1.0°C/W)   Direct IQ down-conversion   Excellent Intermodulation distortion characteristics as channel filter  can be  placed directly after the mixer without impacting noise figure   Digital channel filtering allows for multiple bandwidths with the same hardware  Low  parts  count  and  no  crystal  filters  help  to  keep  receiver  performance  extremely  stable  over temperature   Integrated heat sink   Limits number of mechanical interfaces   Fin design optimized for natural convection   Monitoring and software control   Temperature  control loop  shuts down the  transmitter  when  the temperature  exceeds continuous operation at 70°C   Monitoring of RSSI and PA current to ensure the RF hardware is functioning to specification
 Product Architecture  |  69  Aprisa SR+ Product Description  Aprisa SR+ Radio Block Diagram    Aprisa SR+ Protected Station Block Diagram
70  |  Contact Us   Aprisa SR+ Product Description  7. Contact Us For further information or assistance, please contact Customer Support or your local 4RF representative. Our area representative contact details are available from our website:  4RF Limited 26 Glover Street, Ngauranga PO Box 13-506 Wellington 6032 New Zealand  Email address support@4rf.com Website www.4rf.com Phone number +64 4 499 6000 Fax number +64 4 473 4447 Attention Customer Services

Navigation menu