UP TO 96% THERMAL EFFICIENCY,DIRECT VENT

BTH-120
through
BTH-500

The A.O. Smith Cyclone Xi family of products represents the industry’s most technologically
advanced commercial water heaters. The innovative Cyclone Xi design takes performance to
its highest level with efficiencies of 95% and 96%. Models are available from 120,000 BTUs
and now up to 500,000 BTUs. In addition, the Cyclone Xi features an Intelligent Control
System making it the smartest water heater in the industry.
Cyclone Xi provides outstanding hot water output, with dramatic savings on operating costs
compared to units with standard 80% efficiency. A.O. Smith’s leading-edge engineering
delivers conventional power-vent or sealed combustion power direct-vent versatility, low NOx
emissions and excellent space-saving characteristics. Powered anodes, standard on all
Cyclone Xi models, provide superior tank protection for years of trouble free operation.
INTELLIGENT CONTROL SYSTEM WITH LCD DISPLAY
• Exclusive A.O. Smith designed control
• Provides detailed water heater status information
• Precise temperature control
• Built-in diagnostics
• Run histrory information
SUBMERGED COMBUSTION CHAMBER,
WITH HELICAL HEAT EXCHANGER COIL
• Positioned in center of tank, surrounded by water to virtually
eliminate radiant heat loss from chamber
• Spiral heat exchanger keeps hot burner gases swirling, uses centrifugal
force to maximize efficiency of heat transfer to water in tank
• Spiral heat exchanger prevents scale and sediment from forming on
water-side surface, which can reduce energy efficiency over time
POWERED ANODES STANDARD ON ALL MODELS
• Provides long-lasting tank protection in varying water conditions
• Does not require maintenance or inspection
PERMAGLAS® ULTRA COAT™ GLASS LINING
• Exclusive process provides superior protection against corrosion
• Both sides of heat exchanger coil are lined for protection against flue gas
condensate inside coil
MECHANICAL VENTING VERSATILITY
• Conventional power-venting or sealed combustion direct venting
• Vents vertically or through sidewall
• Direct-vent intake and exhaust pipe can terminate separately outside building,
or through single opening, using concentric vent assembly
• Uses inexpensive PVC, CPVC or ABS pipe for intake and exhaust

Approved,
Rule 1146.2 Low NOx for
California and Texas
BTH-120-250

BTH-300-500

HIGH EFFICIENCY PRE-MIX POWERED BURNER
• Down-fired pre-mix burner provides optimum efficiency and quiet operation
• Top-mounted burner position prevents condensation from affecting burner operation

Page 1 of 4

ACGSS02407
December
July
2007R 2007R

188427_ACGSS02407.indd 1

12/7/07 9:26:21 AM

UP TO 96% THERMAL EFFICIENCY,DIRECT VENT
OTHER CYCLONE Xi FEATURES
SPACE-SAVING DESIGN FOR INSTALLATION FLEXIBILITY
• Reduced footprint, ease of service, protection from water damage in case of flooding
• Easy to remove top cover for convenient access to serviceable parts
• 0˝ installation clearances on sides and rear, 2˝ installation clearance on top, 4˝ alcove installation clearance in front
of unit
• 0˝ clearance to combustibles, approved for combustible floors
FACTORY-INSTALLED TEMPERATURE AND PRESSURE RELIEF VALVE
MAXIMUM HYDROSTATIC WORKING PRESSURE: 160 PSI
HANDHOLE CLEANOUT
• Allows easy access to tank interior for cleaning
CODES AND STANDARDS
•Design-certified by UL (Underwriters Laboratories) International, according to ANSZ21.10.3-CSA4.3 standards
governing storage-type water heaters
• Meets ASHRAE/IESNA 90.1-1999• Design-certified by Underwriters Laboratories to NSF standard 5 for 180° F (62° C) water
• Meets SCAQMD Rule 1146.2 for low-NOx emissions
• ASME tank construction optional on 120 to 250 model sizes. ASME tank construction standard on 300,400 and 500 models
THREE-YEAR LIMITED TANK WARRANTY
• For complete warranty details, consult written warranty shipped with heater, or contact A. O. Smith
INSTALLATION CONSIDERATIONS
1. Condensate Drain – This is a fully condensing water heater and should be located near a drain to permit proper
disposal of condensate.
2. Vent Termination – Exhaust gases of this water heater are less than 140° F. In cold climates water vapor in flue
gases will condense into a cloud of vapor where the vent exits the building. This vapor can gradually discolor exterior
building surfaces. Vent termination should be located where this vapor cloud and potential discoloration are not a
concern. Locating vent termination 6˝ or more from the wall helps vapor from being trapped along a building’s face.
To avoid this problem, the vent can be terminated on the roof. Always locate vent termination above the maximum
snowline, and do not locate vent termination above a walkway.
3 Air Intake – In cold climates, air intake should be located at least three feet from the vent termination of the water
heater and any other appliance vents that discharge moisture-laden air (such as clothes dryers). This will help prevent
freeze-over of the intake screen required to prevent foreign objects from entering the intake pipe. Air intake should be
located above the maximum snowline.
4. Blockage Sensors – The water heater is equipped with sensors to shut it down if blockage of vent or air intake occurs.
A light on the heater’s diagnostic panel will alert service technicians to this problem.
5. Noise – Vent terminal should be located away from bedroom windows or other areas where blower noise will be
objectionable. Avoid venting into corners or confined areas, which will amplify sound. Anchoring intake or vent pipe
to walls or ceilings can cause noise to be transmitted to living areas, and isolation mounts should be used where
anchoring is required.
6 Optional Concentric Vent Kit - Helps to minimize unsightly wall/roof penetrations.
BTH-120 - 300 vent kit p/n 9003910105
BTH-400 - 500 vent kit p/n 9006144005

Page 2 of 4

ACGSS02407

188427_ACGSS02407.indd 2

12/7/07 9:26:22 AM

BTH-120-250

WATER OUTLET
1 1/2˝ NPT

A

B

D

G

C

BTH-300-500

E

F

INSTALLATION CLEARANCES
Sides

0˝

Front

0˝

Rear

0˝

Top

1.5˝

To Combustibles*

MAXIMUM EQUIVALENT
VENT LENGTH:

GAS VALVE PIPING

0˝

• Approved for combustible floors

BTH-120

1/2˝ NPT

BTH-150

3/4˝ NPT

BTH-199

3/4˝ NPT

BTH-250

3/4˝ NPT

BTH-300

1 1/4˝ NPT

BTH-400

1 1/4˝ NPT

BTH-500

1 1/2˝ NPT

BTH120 – 250

using 3˝ pipe:
50 ft.

BTH120 – 250

using 4˝ pipe:
120 ft.

BTH300 – 500

using 3˝ pipe:
not applicable

BTH300 – 500

using 4˝ pipe:
70 ft.

DIMENSIONS AND SHIPPING WEIGHTS
DIMENSIONS
MODEL

A
INCHES/CM

B

C

D

E

F

INCHES/CM INCHES/CM INCHES/CM INCHES/CM INCHES/CM

G

SHIP WEIGHT
STD

SHIP WEIGHT
ASME

INCHES/CM

LBS/KG

LBS/KG

BTH-120

55.5/141

44.5/113

35/88.9

27.75/70.5

7.5/19.1

6.3/16

47/119.4

460Lbs/208.7Kg 490Lbs/222.2Kg

BTH-150

75.5/191.8

64.5/163.8

55.5/141

27.75/70.5

7.5/19.1

6.3/16

68/172.7

555Lbs/251.7Kg 595Lbs/269.9Kg

BTH-199, 250

75.5/191.8

64.5/163.8

55.5/141

27.75/70.5

7.5/19.1

6.3/16

72/182.9

555Lbs/251.7Kg 595Lbs/269.9Kg

BTH-300, 400, 500

75.5/191.8

64.5/163.8

50.77/129 33.12/84.1

8/20.3

4.86/12.3

67.25/170.8

N/A

855Lbs/408.2 Kg

Water connections: 1-1/2˝

Page 3 of 4

ACGSS02407
188427_ACGSS02407.indd 3

12/7/07 9:26:22 AM

UP TO 96% THERMAL EFFICIENCY,DIRECT VENT
RECOVERY CAPACITY
U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED
MODEL

TYPE OF
GAS

NATURAL/
BTH 120
PROPANE

INPUT
BTUH
120,000

35

NATURAL/
BTH 150
PROPANE

150,000

NATURAL/
BTH 199
PROPANE

199,900

NATURAL/
BTH 250
PROPANE

250,000

NATURAL/
PROPANE

300,000

BTH 400

NATURAL/
PROPANE

399,900

BTH 500

NATURAL/
PROPANE

499,900

BTH 300

Thermal
KW Efficiency

44
58
73
88
117
146

95%
95%
95%
95%
96%
96%
95%

Fº

30 Fº

40 Fº

50 Fº

60 Fº

70 Fº

80 Fº

90 Fº

100 Fº 110 Fº 120 Fº 130 Fº 140 Fº

60 U.S. Gal

Cº
GPH

17 Cº
461

22 Cº
345

28 Cº
276

33 Cº
230

39 Cº
197

44 Cº
173

50 Cº
154

56 Cº
138

61 Cº
126

67 Cº
115

72 Cº
106

78 Cº
99

227 Litres

LPH

1744

1308

1046

872

747

654

581

523

476

436

402

374

100 U.S. Gals. GPH

576

432

345

288

247

216

192

173

157

144

133

123

LPH

2179

1635

1308

1090

934

817

726

654

594

545

503

467

100 U.S. Gals. GPH

767

575

460

384

329

288

256

230

209

192

177

164

LPH

2904

2178

1743

1452

1245

1089

968

871

792

726

670

622

100 U.S. Gals. GPH

960

720

576

480

411

360

320

288

262

240

221

206

3632

2724

2179

1816

1557

1362

1211

1044

991

908

838

778

130 U.S. Gals. GPH 1164

873

699

582

499

436

388

349

318

291

269

250

4406

3304

2644

2203

1888

1652

1469

1322

1201

1102

1017

945

130 U.S. Gals. GPH 1552

1164

931

776

665

582

517

465

423

388

359

332

5875

4406

3525

2938

2518

2203

1958

1759

1602

1469

1356

1259

130 U.S. Gals. GPH 1919

1439

1151

959

822

720

640

576

523

480

443

411

5447

4358

3631

3113

2724

2421

2179

1981

1816

1676

1556

Approx.
Capacity

379 Litres
379 Litres
379 Litres
492 Litres
492 Litres
492 Litres

LPH
LPH
LPH
LPH

7263

Recovery capacities are based on heater performance at 95% and 96% thermal efficiency.
Add "A" to model number when ordering ASME. Optional on 120 - 250 models. Standard on 300 - 500 models.
Maximum gas supply pressure for 120 - 250: 10.5" w.c. natural gas 14" w.c propane. Maximum gas supply pressure for 300-500 10" w.c. natural gas 13" w.c. propane.
Manifold pressure: 4" w.c. natural gas 10" w.c. propane. Electrical requirements: 120 VAC, Blower 2.2 Amps FL, Igniter 4.0 Amps.

SUGGESTED SPECIFICATION
(Natural or Propane) gas water heater(s) shall be A. O. Smith Cyclone Xi model # _________ or equal, with up to 96% thermal efficiency, a storage capacity of
______ gallons, an input rating of __________ BTUs per hour, a recovery rating of ___________ gallons per hour (gph) at 100° F rise and a maximum hydrostatic
working pressure of 160 PSI. Water heater(s) shall: 1. Have seamless glass-lined steel tank construction, with glass lining applied to all water-side surfaces
after the tank has been assembled and welded; 2. Have a spiral-shaped heat exchanger placed entirely inside the tank, which shall be glass-lined to protect
against acidic flue gas condensate; 3. Have foam insulation and an ASME-rated temperature and pressure relief valve; 4. Have a down-fired power burner
designed for precise mixing of air and gas for optimum efficiency, requiring no special calibration on start-up; 5. Be approved for 0˝ clearance to combustibles.
Heater shall be supplied with maintenance-free powered anode.
The control shall be an integrated solid-state temperature and ignition control device with integral diagnostics, graphic user interface, fault history display, and
shall have digital temperature readout.
The water heater(s) shall: 1. Be design-certified by UL (Underwriters Laboratories), according to ANSZ21.10 standards governingstorage-type water heaters; 2. Meet
ASHRAE/IESNA 90.1-1999; 3. Be design-certified by Underwriters Laboratories for 180° F (62° C) water; 4. Meet SCAQMD Rule 1146.2 for low-NOx emissions.
For conventional-vent specification: The BTH-120 - 250 water heater(s) shall be suitable for venting in 3˝ PVC pipe for a total equivalent distance of 50 ft
and 4˝ PVC pipe for a total equivalent distance of 120 ft.
The BTH-300 - 500 water heater(s) shall be suitable for venting only in 4˝ PVC pipe, for a total equivalent distance of 70 ft.
For sealed-combustion direct-vent specification: The BTH-120 - 250 water heater(s) shall be suitable for venting with (3˝ or 4˝) _______ diameter PVC pipe for a
total equivalent distance of (50 ft or 120 ft) ________ feet. [Alternative venting: the heater(s) shall be suitable for sealedcombustion direct venting using a (3˝ or 4˝)
________ diameter PVC exhaust pipe for a total distance of (50 ft or 120 ft) ________ equivalent feet of vent and (50 ft or 120 ft) _______ equivalent feet of intake.]
The BTH-300 - 500 water heater(s) shall be suitable for sealed combustion direct-vent using only 4˝ diameter PVC pipe and 4˝ diameter PVC exhaust pipe for a
total equivalent distance of 70 ft.
Operation of the water heater(s) in a closed system where thermal expansion has not been compensated for (with a properly sized thermal expansion tank) will
void the warranty.

For Technical Information and Automated Fax Service, call 800-527-1953.
A. O. Smith reserves the right to make product changes or improvements without prior notice.
Page 4 of 4
December
July 2007R2007R

188427_ACGSS02407.indd 4

Printed in U.S.A.

ACGSS02407

12/7/07 9:26:23 AM



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Page Count                      : 4
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:eaec266a-a4d8-11dc-b301-0003936f9316
Producer                        : Acrobat Distiller 6.0 for Macintosh
Modify Date                     : 2007:12:07 09:27:27-06:00
Creator Tool                    : Adobe InDesign CS (3.0.1)
Create Date                     : 2007:12:07 09:26:32-06:00
Metadata Date                   : 2007:12:07 09:27:27-06:00
Document ID                     : uuid:d19f3956-a4d8-11dc-b301-0003936f9316
Format                          : application/pdf
Creator                         : andy
Title                           : 188427_ACGSS02407.indd
Author                          : andy
EXIF Metadata provided by EXIF.tools

Navigation menu