A O Smith Ati 540H N Technical S

2015-04-13

: A-O-Smith A-O-Smith-Ati-540H-N-Technical-s-693456 a-o-smith-ati-540h-n-technical-s-693456 a-o-smith pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadA-O-Smith A-O-Smith-Ati-540H-N-Technical-s-  A-o-smith-ati-540h-n-technical-s
Open PDF In BrowserView PDF
Residential / Light Commercial
Gas Tankless Water Heaters

TANKLESS HIGH-EFFICIENCY
CONDENSING MODELS
FEATURES
■ 	 Condensing technology provides significant energy cost savings
PRIMARY HEAT EXCHANGER IS CONSTRUCTED OF HRS35 COMMERCIAL
GRADE COPPER
■ 	 Stronger than standard copper and more resilient against erosion

SECONDARY HEAT EXCHANGER IS MADE OF TYPE 316L STAINLESS STEEL
■ 	 Provides additional protection against corrosion
CONTINUOUS MAXIMUM FLOW RATES UP TO 9.0 GPM
CAN BE USED IN RESIDENTIAL AND
LIGHT COMMERCIAL APPLICATIONS
ENERGY STAR® QUALIFIED
MODELS INCLUDE REMOTE CONTROL AND POWER CORD
EASY-LINK UP TO 4 UNITS
■ 	 With no additional parts or accessories needed

ATI-520H-N
ATI-520H-P

ELECTRONIC IGNITION-NO PILOT LIGHT
BUILT-IN DISPLAY SHOWS OPERATING TEMPERATURE ALONG WITH
DIAGNOSTIC ERROR CODES
SAFETY FEATURES
■ 	 Air-Fuel Ratio (AFR) Sensor
■ 	 Exhaust & Water Temperature Safety Controls
■ 	 Overheat Cutoff Fuse
INTERNAL FREEZE PROTECTION SYSTEM
POWER DIRECT VENT DESIGN
■ 	 4” Pipe Vents up to 50 Equivalent Feet or 3” Pipe Vents up to 25 Equivalent Feet
■ 	 ULC s636 approved PVC, CPVC, or Polypropylene Pipe for Intake and Exhaust 	
	

■
	

(solid core only)
	 Category III Stainless Steel venting can also be used
■ 	 Vertical or Horizontal installation

ANSI Z21.10.3

CSA 4.3

ACCESSORIES
■ 	 Remote Temperature Controller (Included)
■ 	 Neutralizer Kit
■ 	 Plumbing Installation Kits
■ 	 PVC Intake Adaptor
■ 	 Concentric Termination
WARRANTY
■ 	 12-year limited warranty on heat exchanger in residential applications
■ 	 5-year limited warranty on heat exchanger in commercial applications
■ 	 5-year warranty on all parts

	
October 2012

Page 1 of 2

CANRG46805

Residential / Light Commercial
Gas Tankless Water Heaters
INDOOR CONDENSING MODELS
CAPACITY & DIMENSIONS
GAS CONSUMPTION INPUT

FUEL
TYPE

MODEL

INLET GAS PRESSURE

MINIMUM
BTU/H

MAXIMUM
BTU/H

MINIMUM
W.C.

MAXIMUM
W.C.

ENERGY
FACTOR

HOT/COLD
GAS CONN.

HEIGHT

WIDTH

DEPTH

APPROX.
SHIPPING
WEIGHT
(LBS)

DIMENSIONS IN INCHES

ATI 520H N

NATURAL

13,000

199,000

5.0

10.5

.91

3/4” NPT

25-3/5

18-1/2

12-2/5

73

ATI 520H P

PROPANE

13,000

199,000

8.0

14.0

.91

3/4” NPT

25-3/5

18-1/2

12-2/5

73

All dimensions in inches.
15-150 psi Water Pressure. 40 psi or above recommended for maximum flow.
18-1/2" (470mm)
12-1/2" (320mm)

12-1/2" (316mm)

3-1/2" (90mm)

Ø4" (102mm) Female

Male Ø4" (100.8mm)

3/4" (18.8mm)

25-1/2" (649mm)

2-3/4" (69.1mm) INTAKE

2-3/4" (71.8mm) EXHAUST

6-5/8" (168.4mm)

1/2" (12.5mm)

29-1/2" (751mm)

6-1/4" (161.5mm)

1-1/4" (29.2mm) COLD

GAS 6" (153.6mm)

120VAC 2-1/4" (58.2mm)

HOT 7-1/4" (182.1mm)
120VAC 8-1/2" (216.3mm)

4-5/8" (116.8mm) GAS

HOT 5-5/8" (142.2mm)

COLD 8-5/8" (220.6mm)

6-1/4" (159.1mm)
Condensate Drain Port

10-1/2" (266.8mm)
Condensate Drain Port

Flow Rate vs. Temperature Rise

50

Pressure Loss

120

45

100

40
35

80

30
25

60

20

40

15
10

20

5
0

0

20

40
60
80
100
Temperature Rise (°F)

120

140

Head Feet

10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0

Pressure Loss (psi)

Flow Rate (gpm)

CLEARANCES: Top: 12”; Bottom: 12”; Front: 4”; Back: .05”; Sides: 3”

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

0
9.0 10.0

Flow Rate (gpm)
Set Temperature : 125 °F & lower
Set Temperature: 130 °F & Higher

For Technical Information, call 1-888-479-8324. A. O. Smith reserves the right to make product changes or improvements without prior notice.

October 2012

	

www.hotwatercanada.ca

Page 2 of 2

CANRG46805



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Instance ID                     : uuid:1c2a4725-9a23-4cfb-a84b-3ddd7a425732
Original Document ID            : adobe:docid:indd:5276faaf-ba7a-11de-afe7-d9815f8efbf9
Document ID                     : xmp.id:9A28ABA662BDE211A6E1975C652A17E3
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:A16BC526CA76E2119CC0878B96DD25F5
Derived From Document ID        : xmp.did:446F92D6DF12E21186FCA045FA6C80FD
Derived From Original Document ID: adobe:docid:indd:5276faaf-ba7a-11de-afe7-d9815f8efbf9
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2013:05:15 09:30:39-04:00
Create Date                     : 2013:05:15 09:30:39-04:00
Modify Date                     : 2013:05:15 09:30:41-04:00
Metadata Date                   : 2013:05:15 09:30:41-04:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu