ACSI Comm. Bath Door System Catalog Series 6100 Communicating Comm

User Manual: ACSI Series 6100 Communicating Bath Door System Catalog Literature

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadACSI Comm. Bath Door System Catalog Series 6100 Communicating Comm
Open PDF In BrowserView PDF
2720 Clark Avenue • St. Louis, Missouri 63103 • 1-800-753-5558 • 314-652-5588 • FAX: 314-652-2090 • WWW.ACSI-INC.COM

L O C K I N T O T H E A C S I A D VA N TA G E
L O C K I N T O T H E A C S I A D VA N TA G E

SERIES

6100

COMMUNICATING

BATH

DOOR

SYSTEM

2720 Clark Avenue • St. Louis, Missouri 63103 • 1-800-753-5558 • 314-652-5588 • FAX: 314-652-2090 • WWW.ACSI-INC.COM

A C S I

1 - 8 0 0 - 7 5 3 - 5 5 5 8

SERIES 6100 C O M M U N I C AT I N G B AT H D O O R S Y S T E M
The ACSI Series 6100 System is designed to coordinate access to a common bathroom facility from
adjoining rooms. This System allows more efficient utilization of floor space in facilities by eliminating the
need for a bathroom in each room.
Features
• Fail safe system - doors will unlock when
power is removed
• Free egress at all times
• User privacy
• Eliminates accidental lock-out of either room
to the bathroom
• Mechanical key override allows personnel to
enter during an emergency
• 1400-6100 Power supply provided

Options (not included)
• Series 6100 System will require one of the
following electric locking devices:
A (2) Mortise locks with ACSI 1510C-00-124VDC/AC modifications plus (2) ACSI
Series 1100 Electric Hinges
B (2) Cylindrical locks with ACSI 1510C-00-124VDC/AC modifications plus (2) ACSI
Series 1100 electric Hinges
C (2) 8500-M-PL-24VAC/AC Gemini Locking
Systems
• 1320-1 pushbutton switch, normally closed, located
above outside doors (used for emergency release).

Note: Electric Lock/Electric Hinge option and the
Gemini option are not included in the
Series 6100 price.

4

Push button to lock doors.
There will be a lock button
at door 1 & door 2 on the
inside of the bathroom.
Both doors will unlock
automatically when
one of the two is
opened. They
will remain
unlocked until
the “push to
lock” button
is pushed.

3

2
1

5
When bathroom is in use the occupied light will come on.
There will be an occupied light at door 1 & door 2 on the
outside of the bathroom.

Item
1

Qty
2 Each

2

2 Each

3
4

2 Each
2 Each

5
6

2 Each
1 Each

Description
Fail Safe locks. Specify one of
the following options:
• M1510C-00-1-24VDC/AC*
• C1510C-00-1-24VDC/AC*
• 8500-M1-PL-24VDC/AC*
Electric hinges, Model 1104
(Not required on 8500 locking
device)
Indicators marked “Occupied”
Pushbuttons with indicator
marked “Push to Lock”
Door position sensors
1400-6100 Power Supply, 24VDC
@ 2 amp (not pictured)

Description of System Function
When the bathroom is not occupied, both doors are unlocked, and all indicators are extinguished. Upon
entering the bathroom from one of the rooms, the occupant depresses the inside push-button switch to lock
both doors (both doors must be closed in order for them to lock). When the doors lock, the red indicators
inside the bathroom indicate that both doors are locked from the outside. The green indicators outside the
bathroom denote that the bathroom is occupied. (Note: Both doors are always free egress and can always
be unlocked mechanically from the outside with a key). When the occupant exits either door, both doors
automatically return to the unlocked condition and all indicators are extinguished.
Note: Electric Hinge option is not included in the Series 6100 price. Consult factory for pricing.
Note: System may be furnished with an emergency release device; i.e., 1330-3 Emergency Release or
1320-1 Pushbutton Switch. Consult factory.

A C S I

HOW TO ORDER
1
Model

2
Electric Locking Device

6100

A, B, or C

1 - 8 0 0 - 7 5 3 - 5 5 5 8

1. 6100 SYSTEM
Model
6100

Description
Communicating Bath Door System

Note: Electric Lock/Electric Hinge option and the Gemini option are not included in the Series 6100
price.

2. ELECTRIC LOCKING DEVICE REQUIRED
The Series 6100 System requires one of the following options:
A. (2) M1510C-00-1-24VAC (Electric Mortise Locks)
B. (2) C1510C-00-1-24VAC (Electric Cylindrical Locks)
C. (2) 8500-ML-PL-24VAC (Gemini Locking System)

Note: Specify lock manufacturer being used; i.e., Schlage, Corbin, Sargent, Yale, etc.
Note: Electric Lock/Electric Hinge option and the Gemini option are not included in the Series 6100
price.

3. 1104 ELECTRIC HINGES
Series 6100 System requires (2) ACSI Series 1104 electric hinges if options A or B are supplied. Please specify
manufacturer, weight, size and finish of the hinge required.
Example:
Hager BB1279 4.5 x 4.5 - 26D - 1104
Stanley FBB191 5 x 4.5
- 10B - 1104
Note: Electric Hinge option is not included in the Series 6100 price. Consult factory for pricing.
Note: System may be furnished with an emergency release device; i.e., 1330-3 Emergency Release or 1320-1
Pushbutton Switch. Consult factory.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 4
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
Creator                         : QuarkXPress(R) 7.5
Producer                        : QuarkXPress(R) 7.5
Create Date                     : 2011:09:29 18:24:28
Modify Date                     : 2011:09:29 18:24:28
Title                           : Comm. Bath Door System Catalog
EXIF Metadata provided by EXIF.tools

Navigation menu