ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-10© 2003, ADC Telecommunications, Inc.3.6 Antenna Cable ConnectionAn N-type female connector is provided on the exterior bottom side of the RU cabinet forconnecting the antenna coaxial cable. The exterior N-type connector is on the surge side of alightning protector that is mounted within the enclosure. On the inside of the enclosure, theprotected side of the lightning protector is also equipped with an N-type female connector. Acoaxial jumper cable (included with the enclosure) is used for connecting the protected side ofthe lightning protector to the ANTENNA port on the STM. 3.7 AC Power Wiring and GroundingThe RU outdoor cabinet is equipped with a stub cable for the AC power connections. The ACpower cable provides three wire leads (Load, Neutral, and Ground) that must be connected to a120 or 240 VAC power source. The AC power cable exits the cabinet though a 3/4-inch NPTthreaded hole located on the bottom of the cabinet. The threaded hole accepts a standard 3/4-inch AC conduit fitting. A 3/4-inch to 1/2-inch reducer is also included if 1/2-inch conduit ispreferred over 3/4-inch conduit.From the exit point in the bottom of the cabinet, the AC power cable must be routed throughconduit to an external AC junction box (not provided) where it can be connected to the ACpower wiring. The junction box should be located within two feet of the cabinet and should beequipped with a 120 VAC outlet for powering test equipment and/or power tools. If AC powerspikes are likely to occur, the junction box should also include a surge protector to protect theequipment from damage. Three wire nuts are included with the cabinet for completing the AC power wiring connections.The junction box wiring should be connected to the AC power source through a 20 Amp breakerbox (not provided). All AC power wiring should be run within conduit. A grounding lug isprovided on the underside of the enclosure for connecting a separate grounding wire directly tothe cabinet. 3.8 VentilationVent openings are provided in the door, on the bottom, and on the rear side of the RU cabinet topermit air exchange for cooling. Air enters the cabinet through the openings in the door andbottom. Filters remove dirt particles so that only clean air enters the enclosure. Both the STMand LPA have cooling fans. The STM has a rear mounted fan that pulls air through the moduleand exhausts it toward the rear of the enclosure. The LPA has a fan on the front that draws airinto the module and exhausts it toward the rear of the enclosure. The heated air exits through anopening in the rear side of the enclosure. 3.9 User InterfaceThe RU cabinet user interface consists of the various connectors, fittings, mounting slots, andswitches that are provided on both the interior and exterior of the enclosure. The user interfacepoints are indicated in Figure 2-4 and described in Table 2-2. FCC ID: F8I-DLC1902A
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-11© 2003, ADC Telecommunications, Inc.Figure 2-4. Remote Unit Outdoor Cabinet User Interface(1) AIR INLETFILTER 18563-B(2) AC POWERCABLE(3) DOOR SWITCH(5) STMMOUNTINGSLOT(4) LPAMOUNTINGSLOT(6) WDM/CWDMMOUNTING SLOT(8)  FIBERSLACK SPOOLS(12) GROUNDINGLUG(11) 3/4-INCH NPTTHREADED HOLE(10) FIBER CABLECONNECTOR(7) CWDM POWERCORDBOTTOM VIEWOF CABINET(9) LIGHTNINGPROTECTOR
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-12© 2003, ADC Telecommunications, Inc.4 REMOTE UNIT INDOOR MOUNTING SHELFThe RU indoor mounting shelf, shown in Figure 2-5, is a rack-mountable framework thatprovides the following basic functions: • Supports the various electronic modules (STM and LPA) and accessories (WDM orCWDM) for mounting within a standard 19-inch, WECO or EIA, equipment rack. • Provides the electrical interface connections for the STM and LPA modules. • Provides an AC power cord for powering the STM module• Provides DC power connections for the CWDM module. 4.1 Primary ComponentsThe RU indoor mounting shelf is a rack-mountable frame assembly that provides mountingslots for the STM, LPA, WDM (accessory), and CWDM (accessory) modules plus connectorsand a wiring harness for interfacing the STM and LPA modules. The indoor mounting shelf isdesigned for mounting in a standard 19-inch, EIA or WECO, equipment rack. The frameassembly is constructed of aluminum and is painted putty white for corrosion protection. Table 2-2. Remote Unit Cabinet User InterfaceREF NO DEVICE FUNCTIONAL DESCRIPTION1 Air inlet filter Reusable filter that prevents the entry of dirt particles when out-side air is pulled into the cabinet for cooling.2 AC power cord Provides AC power to the STM. 3 Door switch Indicates to the fault detection and alarm reporting system if the cabinet door is open (major alarm) or closed. 4 LPA mounting slot Provides a mounting point for the LPA module. 5 STM mounting slot Provides a mounting point for the STM module.6 WDM/CWDM mounting slot Provides a mounting point for either the WDM or CWDM mod-ule. 7 CWDM power cord Provides DC power to the CWDM module.8 Fiber slack spools Provide a storage place for excess fiber pigtail and patch cord slack. 9 Lightning protector Provides lightning surge protection for the antenna connection. 10 Fiber cable connector Provides both an entry point and strain relief for the fiber optic cable. 11 3/4-inch NPT threaded hole Provides a connection point for a 3/4-inch AC conduit fitting. 12 Grounding lug Provides a connection point for an external grounding cable.
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-13© 2003, ADC Telecommunications, Inc.Figure 2-5. Remote Unit Indoor Mounting Shelf4.2 STM and LPA Module InstallationTwo mounting slots are provided within the indoor mounting shelf for installing the STM andLPA modules. The mounting slots include tracks that guide each module into the installedposition. Separate mounting slots are provided for STM and LPA modules. Two D-subconnectors (one male, one female) are located at the rear of each mounting slot. Each mountingslot connector mates with a corresponding D-sub connector located on the rear side of eachmodule. A wiring harness links the mounting slot connectors together. The connectors and theattached wiring harness provide the electrical interface between the STM and LPA modules.The modules are held in the installed position with captive screws. 4.3 WDM and CWDM InstallationMounting slots are provided in the indoor mounting shelf for installing a WDM or CWDMmodule (accessory items). Each module is equipped with push-pull type fasteners for securingthe module to the mounting slot. A power cable is included with the mounting shelf forsupplying DC power when a CWDM module is installed. 4.4 Fiber Optic Cable InstallationFiber optic cables and patch cords should be routed to the indoor mounting shelf using existingfiber management systems. All fiber optic connections are made directly with the STM, WDM,or CWDM modules. It is recommended that some provision be made at the mounting shelf forstoring excess patch cord slack. 14.15 IN.(359 MM)16.1 IN.(409 MM)17.39 IN.(442 MM)18565-A
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-14© 2003, ADC Telecommunications, Inc.4.5 Antenna Cable ConnectionsThe antenna cable should be routed to the indoor mounting shelf for connection to the STMmodule. If lightning protection is required, it is recommended that a lightning protector(accessory) be installed near the point where the antenna cable enters the building or enclosure. 4.6 AC Power Wiring and GroundingA standard three-conductor AC power cord is provided with the indoor mounting shelf for theAC power connections. The receptacle end of the power cable connects to the AC connector onthe STM. The plug end of the power cable connects to a standard 120 VAC outlet. If AC powerspikes are likely to occur, a surge protector should be installed to protect the equipment fromdamage. A grounding stud is provided on the left side of the mounting shelf for connecting aseparate grounding wire directly to the mounting shelf chassis. 4.7 User InterfaceThe RU mounting shelf user interface consists primarily of the mounting slots and AC and DCpower cables. The user interface points are indicated in Figure 2-6 and described in Table 2-3. Figure 2-6. Remote Unit Indoor Mounting Shelf User Interface18642-A(1) STM MOUNTINGSLOT(2) LPA MOUNTINGSLOT(4) AC POWERCABLE(5) WDMMOUNTINGSLOT(6) CWDMMOUNTINGSLOT(7) CWDM DCPOWER CABLE(3) GROUNDINGSTUDS (INSIDE)
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-15© 2003, ADC Telecommunications, Inc.5 SPECTRUM TRANSPORT MODULEThe Spectrum Transport Module (STM), shown in Figure 2-7, provides the following basicfunctions:• Provides an RF interface (antenna port) to the remote antenna. • Provides an optical interface to the HU. • Converts the digitized forward path optical signal to a digitized RF signal. • Converts the digitized RF signal to a composite RF signal. • Digitizes the reverse path composite RF signal. • Converts the digitized reverse path RF signal to a digitized optical signal. • Provides an RS-232 interface for connecting a local EMS computer. • Transports alarm, control, and monitoring information to the HU via the optical link. • Provides an AC power interface. • Provides an external alarm interface. 5.1 Primary ComponentsThe STM consists of an electronic circuit board assembly, power supply, duplexer, and fanassembly that are mounted within a powder-paint coated sheet metal enclosure. The metalenclosure provides a mounting point for the electronic components and also controls RFemissions. Except for the fan unit, the electronic components are not user replaceable. The STMis designed for use within the RU outdoor cabinet or indoor mounting shelf. Except for the LPAinterface connector, all controls, connectors, indicators, and switches are mounted on the STMfront panel for easy access. A carrying handle is provided on the front of the STM to facilitateinstallation and transport. Table 2-3. Remote Unit Outdoor Mounting Shelf User InterfaceREF NO DEVICE FUNCTIONAL DESCRIPTION1 STM mounting slot Provides a mounting point for the STM module.2 LPA mounting slot Provides a mounting point for the LPA module.3 Grounding lug Provides a connection point for an external grounding cable. 4 AC power cable Provides AC power to the STM.5 WDM mounting slot Provides a mounting point for the WDM module. 6 CWDM mounting slot Provides a mounting point for the CWDM module.7 CWDM power cord Provides DC power to the CWDM module.
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-16© 2003, ADC Telecommunications, Inc.Figure 2-7. Spectrum Transport Module5.2 MountingThe STM mounts within the RU outdoor cabinet or indoor mounting shelf. A runner on thebottom of the STM meshes with a track. The runner and track guide the STM into the installedposition. The electrical interface between the STM and LPA is supported by a D-sub femaleconnector located on the rear side of the STM. A corresponding D-sub male connector mountedat the rear of the RU cabinet or RU mounting shelf mates with the STM connector. Captivescrews are provided for securing the STM in the installed position. 5.3 Fault Detection and Alarm ReportingThe STM detects and reports various faults including remote unit fault, optical fault, powerfault, temperature fault, power amplifier fault, and external (door open) fault. Various frontpanel Light Emitting Diode (LED) indicators turn from green to red or yellow if a fault isdetected. The status of the STM, the alarm state (major or minor), and other alarm informationis summarized and reported over the optical  interface to the HU and also over the serviceinterface. In addition, the alarm state of the HU is received over the optical  interface andreported to the service interface. This information may be accessed remotely through the NOC/NEM interface or locally through the EMS software GUI. 5.4 Antenna Cable ConnectionThe antenna cable connections between the STM and the antenna are supported through one N-type female connector which carries both the forward and reverse path RF signals. Wheninstalled in the RU outdoor cabinet, the STM does not connect directly to the antenna but18634-B
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-17© 2003, ADC Telecommunications, Inc.instead connects to a lightning protector that is mounted on the bottom of the cabinet (seeSection 3.6). A coaxial jumper cable is provided (included with the enclosure) for connectingthe STM to the lightning protector. 5.5 RF Signal Level AdjustmentThe STM is equipped with a digital attenuator for adjusting the signal level of the forward pathRF output signal. The remote forward path attenuator adjusts the level of the output RF signalat the RU antenna port and will add from 0 to 31 dB of attenuation to the output signal level.The attenuator can be set in 1 dB increments. The attenuator is software controlled and isadjusted through the NOC/NEM interface or the EMS software GUI. 5.6 Optical ConnectionFiber optic connections between the STM and the HU are supported through two SC-typeoptical connector ports. One port is used for connecting the forward path optical signal and theother port is used for connecting the primary reverse path optical signal. 5.7 Service Interface ConnectionThe service interface connection between the STM and a local laptop computer loaded with theEMS software is supported by a single DB-9 female connector. The service interface connectorprovides an RS-232 DTE interface. The STM service interface connector supports localcommunications with both the STM and the corresponding HU. 5.8 PoweringThe STM is powered by 120 or 240 VAC (50 or 60 Hz) power which is supplied through athree-conductor AC power cord. The power cord is provided with the RU outdoor cabinet orindoor mounting shelf. The power cord connects to an AC connector mounted on the STM frontpanel. A switch on the STM front panel provides AC power On/Off control. 5.9 CoolingContinuous air-flow for cooling is provided by a single fan mounted on the rear side of the STMhousing. An alarm is provided that indicates if a high temperature condition (>50º C/122º F)occurs. If the temperature falls below 32º F (0º C), the fan automatically shuts off. The fan maybe field replaced if it fails. 5.10 User InterfaceThe STM user interface consists of the various connectors, switches, and LEDs that areprovided on the STM front panel. The STM user interface points are indicated in Figure 2-8 anddescribed in Table 2-4.
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-18© 2003, ADC Telecommunications, Inc.Figure 2-8. Spectrum Transport Module User InterfaceTable 2-4. Spectrum Transport Module User InterfaceREF NOUSER INTERFACE DESIGNATION DEVICE FUNCTIONALDESCRIPTION1 PORT 1 SC connector(single-mode) Input connection point for the forward path opti-cal fiber.2 PORT 2 SC connector(single-mode) Output connection point for the reverse path pri-mary optical fiber.3I/0 On/Off rocker switch Provides AC power on/off control. 4 No designation 3-wire AC power cord connector Connection point for the AC power cord. 5 No designation 2- wire DC power cord connector Connection point for a back-up battery power cord. (Not used with 20 Watt system)6 SERVICE DB-9 connector (female) Connection point for the RS-232 service inter-face cable. 7 AC POWER Multi-colored LED(green/red)Indicates if the STM is powered by the AC power source (green) or the back-up battery system (red). See Note.18636-B(3) ON/OFFSWITCH(4) AC POWERCONNECTOR(5) DC POWERCONNECTOR(1) PORT 1CONNECTOR(2) PORT 2CONNECTOR(6) SERVICECONNECTOR(7-13) LEDINDICATORS(14) ALARMCONNECTOR(15) ANTENNACONNECTOR
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-19© 2003, ADC Telecommunications, Inc.6 LINEAR POWER AMPLIFIERThe Linear Power Amplifier (LPA), shown in Figure 2-9, works in conjunction with the STM toamplify the forward path RF output signal. The STM is interfaced with the LPA through theD-sub connectors and wiring harness located at the rear of the RU cabinet or RU mountingshelf. The RF signal is passed to the LPA for amplification and then passed back to the STM forfiltering and output via the STM’s ANTENNA port. The STM also supplies DC power to theLPA through the same interface. 6.1 Primary ComponentsThe LPA consists of a fan and several electronic circuit board assemblies that are mountedwithin a powder-paint coated sheet metal enclosure. The metal enclosure provides a mountingpoint for the electronic components and also controls RF emissions. Except for the fan unit, theelectronic components are not user replaceable. The LPA is designed for use within the RUoutdoor cabinet or RU indoor mounting shelf. Except for the STM interface connector, allcontrols, indicators, and switches are mounted on the LPA front panel for easy access. Acarrying handle is provided on the front of the LPA to facilitate installation and transport. 8 STANDBY Multi-colored LED(green/yellow/red)Indicates if the system is in the Normal state (off) Standby state (blinking green), Test state (blink-ing red), or Program Load state (blinking yel-low). See Note. 9 HOST UNIT Multi-colored LED(green/yellow/red)Indicates if no alarm (green), a minor alarm (yel-low), or a major alarm (red) is reported by the HU. See Note.10 STM Multi-colored LED(green/yellow/red)Indicates if the STM is normal (green) or faulty (red). See Note.11 PA Multi-colored LED(green/yellow/red)Indicates if the power amplifier is normal (green), over temperature (yellow), has a fan fail-ure (yellow), or is faulty (red). See Note.12 VSWR Multi-colored LED(green/yellow/red)Indicates if the forward path VSWR is above (red) or below (green) the fault threshold. 13 PORT 1/PORT 2 Multi-colored LED(green/red)Indicates if the forward/reverse path optical sig-nal from the STM/HU are normal (green), if no optical signals are detected (red), or if excessive errors are detected (red). See Note. 14 ALARM IN MINORALARM IN MAJORScrew-type terminalconnector (14–26 AWG)Connection point for two external alarm inputs. The door-open switch lead wires are typically connected to the major alarm terminals. 15 ANTENNA N-type female RF coaxial connector Connection point for the antenna. Note: A more detailed description of LED operation is provided in Section 5.Table 2-4. Spectrum Transport Module User Interface, continuedREF NOUSER INTERFACE DESIGNATION DEVICE FUNCTIONALDESCRIPTION
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-20© 2003, ADC Telecommunications, Inc.Figure 2-9. Linear Power Amplifier6.2 MountingThe LPA mounts within the RU outdoor cabinet or RU indoor mounting shelf. Runners on thetop and bottom of the LPA mesh with tracks. The runners and tracks guide the LPA into theinstalled position. The electrical interface between the STM and LPA is supported by a D-subfemale connector located on the rear side of the LPA. A corresponding D-sub male connectormounted at the rear of the RU outdoor cabinet or RU indoor mounting shelf mates with the LPAconnector. Captive screws are provided for securing the LPA in the installed position. 6.3 Fault Detection and Alarm ReportingThe LPA in conjunction with the STM detects and reports various faults including poweramplifier fault, output power fault, temperature fault, and fan fault. A single Light EmittingDiode (LED) indicator, located on the front panel of the LPA, turns from green to red or yellowif an LPA fault is detected. The status of the LPA, the alarm state (major or minor), and otherinformation is summarized and reported (by the STM) over the optical fiber to the HU and alsoto the service interface. This information may be accessed remotely through the NOC/NEMinterface or locally through the EMS software GUI. 6.4 PoweringThe LPA is powered by various DC voltages which are supplied by the STM over the electricalinterface provided by the D-sub connectors and wiring harness mounted within the RU outdoorcabinet or RU indoor mounting shelf. 18796-A1900 MHz 20 WATT
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-21© 2003, ADC Telecommunications, Inc.6.5 CoolingContinuous air-flow for cooling is provided by a fan mounted at the front of the LPA housing.Cool air is pulled into the module from the front and heated air is exhausted out the back. Analarm is provided that indicates if a high temperature condition (>50º C/122º F) occurs or if afan failure occurs. The fan may be field replaced if it fails. 6.6 User InterfaceThe LPA user interface consists of an LED indicator and a switch that are mounted on the LPAfront panel. The LPA user interface points are described in Table 2-5 and indicated inFigure 2-10. Figure 2-10. Linear Power Amplifier User InterfaceTable 2-5. Linear Power Amplifier User InterfaceREF NOUSER INTERFACE DESIGNATION DEVICE FUNCTIONALDESCRIPTION1 STATUS LED indicator (green, yellow, and red)Indicates the operational state of the LPA and whether or not there are any faults. 2MUTENORMRESET3-position switch with one momentary contact positionPlacing the switch in the MUTE position puts the LPA in the shutdown state with RF output disabled. With the switch in MUTE, the STM can not control the LPA output power. Placing the switch in the NORM position puts the LPA in the normal state and allows the STM to enable and disable the RF output. Momentarily placing the switch in the RESET position clears all alarms and restarts the LPA. Note: A more detailed description of the STATUS LED is provided in Section 5. 18797-A(1) STATUS(2) MUTE/NORM/RESET SWITCH1900 MHz 20 WATT
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-22© 2003, ADC Telecommunications, Inc.7 INTERFACE PANELS (ACCESSORY)The interface panels are accessory items that are used when multiple BTS’s and multiple HU’srequire connection or when RF attenuation is needed between the BTS and HU. Two types ofpanels are available: the Conditioning Panel and the Duplexing Panel. The Conditioning Panel,shown in Figure 2-11, provides attenuation of the forward path signal to the level required forinput to the HU. The Conditioning Panel also provides forward and reverse path combining andsplitting (as needed) to enable multi-BTS to single HU, multi-BTS to multi-HU, or single BTSto multi-HU configurations. Figure 2-11. Conditioning PanelThe Duplexing Panel, shown in Figure 2-12, is used in conjunction with the Conditioning Panelwhen the BTS provides a duplexed forward and reverse path RF connection. The DuplexingPanel separates the duplexed forward and reverse path signals. This allows the BTS to beconnected to the HU which has separate forward and reverse path RF ports. For completeinformation about the Conditioning Panel and Duplexing Panel, refer to the Digivance RFTransport Solution 800 and 1900 MHz Interface Panels User Manual (ADCP-75-144). Figure 2-12. Duplexing Panel18644-A18645-A
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-23© 2003, ADC Telecommunications, Inc.8 WAVELENGTH DIVISION MULTIPLEXER SYSTEM (ACCESSORY)The Wavelength Division Multiplexer (WDM) system is an accessory product that is used whenit is desirable or necessary to combine the forward and reverse path optical signals from oneDigivance system onto a single optical fiber. Each WDM system consists of a host module, hostmodule mounting shelf, and remote module. The WDM host module mounting shelf cansupport two WDM host modules. The RU indoor mounting shelf provides a mounting slot forinstalling a WDM remote module. Each WDM module consists of either one (remote module) or two (host module) bi-directionalwavelength division multiplexers mounted within a power-paint coated sheet metal enclosure.An SC-type optical connector port is provided for connecting the forward/reverse path opticalfiber to the WDM module. A pair of pigtail leads with SC-type connectors are provided forconnecting the WDM module to the forward and reverse path optical ports on the HU or STM. The WDM host module and host module mounting shelf are shown in Figure 2-13. The WDMremote module is shown in Figure 2-14. Figure 2-13. WDM Host Module and Host Module Mounting ShelfFigure 2-14. WDM Remote Module18646-A17013-A
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-24© 2003, ADC Telecommunications, Inc.9 COARSE WAVELENGTH DIVISION MULTIPLEXER SYSTEM (ACCESSORY)The Coarse Wavelength Division Multiplexer (CWDM) system is an accessory product that isused when it is desirable or necessary to combine the forward and reserve path optical signalsfor up to four Digivance systems onto a single optical fiber. Each CWDM system consists of aHost Module, Host Module mounting shelf, and Remote Module. The CWDM Host Modulemounting shelf can support up to three CWDM Host Modules. Both the RU outdoor cabinet andindoor mounting shelf provide a mounting slot for installing a CWDM Remote Module. The CWDM Host Module and Host Module Mounting Shelf are shown in Figure 2-15. TheCWDM Remote Module is shown in Figure 2-16. For complete information about the CWDMsystem, refer to the Digivance System Coarse Wavelength Division Multiplexer User Manual(ADCP-75-142). Figure 2-15. CWDM Host Module and Host Module Mounting ShelfFigure 2-16. CWDM Remote Module18647-A18648-A
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-25© 2003, ADC Telecommunications, Inc.10 DIGIVANCE ELEMENT MANAGEMENT SYSTEMThe Digivance Element Management System (EMS) is a network management tool that providescontrol and monitoring functions for the Digivance system. The EMS is used to provision andconfigure new systems for operation, set system operating parameters, get system alarm andstatus messages, and upgrade the system software. The EMS supports both local control by anon-site service technician and remote control by a Network Operations Center (NOC). 10.1 Primary ComponentsThe EMS, shown in Figure 2-17, consists of a PC-type desk-top computer (not provided) that isloaded with the EMS software. The EMS software is stored on a CD-ROM that is shippedseparately along with a User Manual and mouse pad. The EMS software must be installed onthe EMS computer along with the Java 2 Version 1.3.1 Runtime Environment software which isalso provided. Installation consists of inserting the CD-ROM into the computer’s CD-ROMdrive and then running the software install programs. This places the Java 2 RuntimeEnvironment and EMS software files in assigned folders on the computer’s hard drive. Figure 2-17. Digivance Element Management SystemThe EMS software may also be installed on a PC-type lap-top computer (not provided). A lap-top version of the EMS computer can be used as a portable network management tool forservice and maintenance purposes. A laptop EMS computer can be connected temporarily to asystem to enter the initial configuration data or to trouble-shoot problems and then removedwhen the task is completed. Permanent control and monitoring functions would be provided bythe desk-top EMS computer. EMS CD-ROM MANUALS CD-ROMORNOTE: COMPUTERNOT PROVIDED16803-CUSER MANUAL MOUSE PAD
ADCP-75-158 • Preliminary Issue A • June 2003 • Section 2: DescriptionPage 2-26© 2003, ADC Telecommunications, Inc.10.2 Service Interface ConnectionThe service interface connection between the EMS computer and the HU or RU requires thatthe EMS computer be equipped with a DB-9 connector that is configured to provide an RS-232DCE interface. A straight-through RS-232 interface cable (accessory item) equipped with amale DB-9 connector on one end and a PC-compatible connector on the other end is required tolink the EMS computer to the HU. When multiple HUs are networked together, the EMScomputer may be connected to the service connector on any one of the networked HUs. 10.3 NOC Interface ConnectionThe NOC interface connection between the EMS computer and the NOC requires that the EMScomputer be equipped with a connector that is configured to provide an RS-232 ASCIIinterface. The link between the EMS computer and the NOC would generally be supported by adata network. Cables and equipment (not provided) to support the RS-232 interface connectionbetween the EMS computer and the data network are required. 10.4 EMS Software User InterfaceThe EMS software provides two user interfaces: the Graphical User Interface (GUI) and theNetwork Operation Center-Network Element Manager (NOC/NEM) interface. Both interfacesprovide essentially the same functionality except only the GUI can upgrade the Digivancesystem with new system software. In addition, only the NOC/NEM interface can record andplay back alarm data. The GUI is presented at the EMS computer or on a laptop computer. The GUI is used for localcontrol and monitoring operations. The GUI consists of a series of displays and screens, such asthe one shown in Figure 2-18, that provide the user with alarm and status information and thatallow the user to set various operating parameters. Figure 2-18. EMS Graphical User Interface Host/Remote Display