ADC Telecommunications DLC1902A Digivance 1900 MHz 20 Watt System User Manual 75158
ADC Telecommunications Inc Digivance 1900 MHz 20 Watt System 75158
Contents
manual 5
FCC ID: F8I-DLC1902A ADCP-75-158 • Preliminary Issue A • June 2003 • Section 4: Operation Click to view drop down menu Figure 4-1. Digivance Element Management System Main Window 9. Open the View drop down menu and connect to the Host and Remote pair by selecting “NotNamed/NotNamed”. The HOST Alarms display and the REMOTE Alarms display will open within the main window as shown in Figure 4-2. 10. Verify that the Host and Remote Unit are loaded with the current system software and download the current software to both the Host and the Remote unit if necessary. Refer to Section 2.2 for details. Host/Remote pair site name Clicking on the tabs in this list will open the corresponding display. Figure 4-2. Selecting Display Tabs Page 4-4 © 2003, ADC Telecommunications, Inc. ADCP-75-158 • Preliminary Issue A • June 2003 • Section 4: Operation 11. Click on the HOST Config tab and on the REMOTE Config tab (see Figure 4-2). The HOST Config display and the REMOTE Config display will open within the main window. 12. Enter the Site Name and Site Number for both the HOST and the REMOTE unit. Refer to Section 2.4 for details. 13. If the site has multiple host units, reconnect the CAN cables to the HU’s NET IN and NET OUT ports. 14. Verify that no Major (except Major Extern Alarm) or Minor alarms are being reported in either the HOST or REMOTE Alarm displays and that all alarm fields (except Major Extern Alarm) are green. 15. Click on the HOST RF tab (see Figure 4-2). The HOST RF display will open within the main window. 16. Enter the Host Fwd Att (Forward Attenuation) values. This sets the forward input RF signal level at the HU. Refer to Section 2.5 for details. By default, this value is set to 0 dB. If the DRIVE LED on the HU front panel was red, it should turn green when this step is completed. 17. Determine if the RF output power at the STM ANTENNA is at the correct level per channel up to a composite maximum of +40.5 dBm. Refer to Section 2.6 for details. 18. Place the MUTE/NORM/RESET switch (on LPA front panel) in the NORM position. 19. Verify that the STATUS indicator (on LPA front panel) turns from steady green to blinking green. 20. Click on the REMOTE LPA tab (see Figure 4-2). The REMOTE PA display will open within the main window. 21. Enter the Remote Fwd Att value. This adjusts the RF output signal level at the STM ANTENNA port. Refer to Section 2.7 for details. By default this value is set to 0 dB. 22. Click on the HOST RF tab (see Figure 4-2). The HOST RF display will open within the main window. 23. Enter the Host Rev Att (Reverse Attenuation). This sets the reverse output RF signal levels at the HU. Refer to Section 2.8 for details. 24. If a delay adjustment is required per the system design plan, enter the Host Fwd Delay and Host Rev Delay values. By default, the delay values are set to 0. Refer to Section 2.9 for details. 25. If a separate laptop computer loaded with the EMS software was used to initially configure the system, disconnect the laptop computer from the SERVICE connector on the HU front panel. Note: For continuous monitoring of alarms, each HU and RU pair must remain permanently connected to a PC-type desktop computer loaded with the EMS software. When two or more systems are connected together through the CAN interface, only one EMS computer is required to manage the networked HU and RU systems. The EMS computer may be connected to the SERVICE port on any one of the HUs in the network. 26. Reconnect the external alarm system or notify the alarm system provider that the turn-up process has been completed. Page 4-5 © 2003, ADC Telecommunications, Inc. ADCP-75-158 • Preliminary Issue A • June 2003 • Section 4: Operation 2.2 Verify/Download HU and RU System Software The HU’s and RU’s may require a system software download if they are not loaded with the current system software. Use the following procedure to check the version number of the system software and if necessary to download the current system software: 1. Click on the HOST Prg Load tab and on the REMOTE Prg Load tab. The HOST Prg Load display and the Remote Prg Load display will open within the EMS main window as shown in Figure 4-3. Verify software version before starting download. Click to start download to HOST. Click to open Select Control Program window for HOST Click to start download to REMOTE. Click to open Select Control Program window for REMOTE. Verify software version before starting download. Figure 4-3. HOST and REMOTE Prg Load Displays 2. Click on the HOST Select button (see Figure 4-3). The Select Control Program File window will open as shown in Figure 4-4. Browse until the folder where the Control Program files are located is selected and the software files are displayed in the window. Page 4-6 © 2003, ADC Telecommunications, Inc.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Modify Date : 2003:08:19 20:40:55-05:00 Create Date : 2003:08:18 21:36:31-05:00 Title : 75158.book Creator : FrameMaker 6.0 Producer : Acrobat Distiller 4.0 for Windows Page Count : 3 Mod Date : 2003:08:19 20:40:55-05:00 Creation Date : 2003:08:18 21:36:31-05:00 Metadata Date : 2003:08:19 20:40:55-05:00EXIF Metadata provided by EXIF.tools